MONTHYEARML0934200682009-12-10010 December 2009 University of Maryland, Request for Additional Information Regarding the License Renewal for the Maryland University Training and Research Reactor Project stage: RAI ML1008402392010-04-0606 April 2010 University of Maryland, Request for Additional Information Regarding License Renewal Technical Matters (Tac ME1592) Project stage: RAI ML1012001612010-05-0303 May 2010 Notice of Meeting with the University of Maryland to Discuss Delays in the Review of the License Renewal Application for the Maryland University Training Reactor Project stage: Meeting ML1013202942010-05-13013 May 2010 Revised Notice of Public Meeting with University of Maryland to Discuss Delays in the Review of the License Renewal Application for the Maryland University Training Reactor Project stage: Meeting ML1013704412010-05-17017 May 2010 The Damaging Effects of the Ten-Year Delay by the NRC of the Maryland University Training Reactors License Renewal Application Project stage: Other ML1014106092010-05-26026 May 2010 Summary of Public Meeting with the University of Maryland to Discuss Delays in the Review of the License Renewal Application for the Maryland University Training Reactor Project stage: Meeting ML1016704132010-05-27027 May 2010 University of MD Training Reactor (Mutr) - Submitting Responses to NRC 12/10/09 Request for Additional Information Regarding Financial Qualifications for Renewal of License Project stage: Request ML1018000462010-07-19019 July 2010 FRN: General Notice, Notice of Acceptance for Docketing and Opportunity for Hearing on the Application Renewal of Facility Operating License No. R-70 for Addl 20 Years for MD University Training Reactor Project stage: Acceptance Review ML1020802412010-07-26026 July 2010 University of Maryland - Determination of Acceptability and Sufficiency for Docketing and Opportunity for a Hearing Regarding the Application for Renewal of Facility Operating License No. R-70 for Maryland University Reactor Project stage: Other ML1021100492010-07-28028 July 2010 University of Maryland Responses Request for Additional Information Regarding the License Renewal for Maryland University Training Reactor Project stage: Request ML1021500112010-08-0404 August 2010 University of Maryland-Correction to Transmittal Letter Dated July 26, 2010 Determination of Acceptability and Sufficiency for Docketing and Opportunity for a Hearing Regarding the Application for Renewal of FOL No. R-70 for Umtr Project stage: Other ML1022303382010-08-20020 August 2010 University of Maryland Training Reactor, Request for Additional Information Regarding License Renewal Revised Technical Specifications Dated December 18, 2006 (Tac No. ME1592) Project stage: RAI ML1024401162010-08-27027 August 2010 University of Maryland, Request for Extension to Submit Reply to Request 2 in NRCs April 6, 2010 Additional Information Request Project stage: Request ML1027105562010-09-22022 September 2010 University of Maryland, Request for Additional Information Regarding the License Renewal for the Maryland University Training Reactor Project stage: Request ML1027402492010-10-0808 October 2010 University of Maryland - Approval of Request for an Extension, University of Maryland Request for Additional Information Dated August 20, 2010 Project stage: RAI ML1027402452010-10-0808 October 2010 University of Maryland - Approval of Request for an Extension, University of Maryland Response to Request for Additional Information Dated May 27, 2010 Project stage: RAI ML1035001312010-12-14014 December 2010 University of Maryland, Maryland University Training Reactor (Mutr), Request for an Extension of Time to Submit the Final Calculation File to RAIs 2a and 2b and to Respond to Questions to Be Raised Regarding the Remaining 16 Technical Speci Project stage: Request ML1100300022010-12-29029 December 2010 E-mail Dated December 29, 2010 from Ms. Lori Byrne, Environmental Review Coordinator, MD DNR to Mr. Spyros Triaforos, PM, NRC Rare, Endangered, or Threatened Species Confirmation for the EA for License Renewal of U of MD Project stage: Other ML1101903472011-01-20020 January 2011 University of Maryland - Approval of Request for an Extension, University of Maryland Request for Additional Information Dated August 20, 2010 (TAC No. Me1592) Project stage: RAI ML1101903632011-01-20020 January 2011 University of Maryland - Approval of Request for an Extension, University of Maryland Response to Request for Additional Information Dated August 27, 2010 Project stage: RAI ML1103204592011-01-31031 January 2011 University of Maryland, Maryland University Training Reactor (Mutra), Request for Additional Information (RAI) Regarding Remaining Technical Specifications Project stage: Request ML1109402122011-02-17017 February 2011 University of Maryland, Note to File from Project Manager, Spyros Traiforos Regarding Review of Request for Additional Information Responses Dated January 31, 2011 from University of Maryland and Documenting Upcoming Site Visit on February Project stage: RAI ML1109401752011-02-17017 February 2011 University of Maryland, E-mail Communication to University of Maryland Mohamad Al-Sheikhly from NRC Project Manager, Spyros Traiforos Comments Response to Request for Additional Information and Site Visit on February 18, 2011 Project stage: RAI ML1109401972011-02-17017 February 2011 University of Maryland, NRC Comments Responses to Requests for Additional Information Submitted to Licensee Prior to Site Visit on February 18, 2011 Project stage: RAI ML1109402192011-03-0404 March 2011 University of Maryland, Follow-up E-mail Correspondence Regarding Site Visit and Review of NRC Comments to Responses to Request for Additional Information Dated January 31, 2011 with Additional Information Sent as Attachments to e-mail Project stage: RAI ML1109402222011-03-0404 March 2011 University of Maryland, Summary of Meeting at Site Visit on February 18, 2011 Regarding Comments from NRC to U of MDs Responses to Requests for Additional Information Dated January 31, 2011 with Additional Information and Milestones Project stage: RAI ML1109402362011-03-0404 March 2011 University of Maryland, Milestones Provided to University of Maryland Via E-mail Dated March 4, 2011 and Included as an Attachment to the Summary of the Site Visit Project stage: Other ML1108000452011-03-17017 March 2011 University of Maryland, Training Reactor - Request for Extension of Time Project stage: Request ML1109500562011-04-12012 April 2011 University of Maryland, Approval of Extension Request for Response Time to Requests for Additional Information (Tac No. ME1592) Project stage: RAI ML11124A1242011-05-0202 May 2011 University of Maryland, Maryland University Training Reactor (Mutr), Technical Specifications, Response to February 18, 2011, Request for Additional Information (RAI) Regarding Remaining Technical Specifications Project stage: Request ML11171A5662011-06-22022 June 2011 University of Maryland, NRC Response to Letter Dated May 2, 2011 Project stage: Other ML11189A0652011-07-0505 July 2011 University of Maryland, Maryland, Response to Request for Additional Information in Regard to Remaining Technical Specifications Project stage: Response to RAI ML16231A3392011-07-29029 July 2011 University of Maryland, Maryland University Training Reactor (Mutr) Docket No. 50-166, License No. R-70, Response to Request for Additional Information (RAI) Regarding Maximum MHA Dose (Redacted) Project stage: Response to RAI ML1121300862011-08-26026 August 2011 University of Maryland - Request for Additional Information Regarding the License Renewal for the Maryland University Training Reactor (Related to May 2, 2011) (Tac No. ME1592) Project stage: RAI ML1123806212011-09-0808 September 2011 University of Maryland - Request for Additional Information Regarding Dose Calculations Project stage: RAI ML11277A0262011-09-28028 September 2011 University of Maryland, Request for Additional Information Regarding License Renewal for Maryland University Training Reactor Project stage: Request ML11286A3372011-10-12012 October 2011 University of Maryland - Request for Additional Information Regarding the License Renewal for the Maryland University Training Reactor Project stage: Request ML1133300302011-11-23023 November 2011 University of Maryland, E-mail from M. Al-Sheikhly, Umd to J. Lising, NRC Request for Additional Information Extension Request (Tac No. ME1592) Project stage: Request ML1133300392011-12-0101 December 2011 University of Maryland - Approval for Request for Additional Time to Respond to NRC Request for Additional Information Project stage: RAI ML11363A1762011-12-19019 December 2011 Annual Report: July 1, 2010 - June 30, 2011 for the Maryland University Training Reactor (Mutr) Project stage: Other ML1201702562012-01-0606 January 2012 University of Maryland, E-mail Requesting Extension to NRC Request for Additional Information AR-41 Measurements and Analyses (Tac No. ME1592) Project stage: Request ML12060A3442012-02-0909 February 2012 University of Maryland - Response to NRC Request for Additional Information Regarding the License Renewal for the Maryland University Training Reactor Project stage: Response to RAI ML12172A1392012-05-22022 May 2012 University of Maryland, Request for Additional Information Regarding the License Renewal for the Maryland University Training Reactor (Mutr) Project stage: Request ML12255A4002012-08-29029 August 2012 University of Maryland, Response to Request for Additional Information Regarding the License Renewal for the Training Reactor (Mutr) Project stage: Response to RAI ML12306A1122012-11-15015 November 2012 University of Maryland - Review and Approval of the Requalification Training Program for Licensed Operators (Tac No. ME1592) Project stage: Other ML13095A0062013-03-21021 March 2013 University of Maryland - License Renewal for the Maryland University Training Reactor (Mutr), TAC ME1592 Project stage: Other ML13303B5622013-10-22022 October 2013 Annual Report: July 1, 2013 for the Maryland University Training Reactor, Docket No. 05000166, License No. R-70 (TAC ME1592), University of Maryland Project stage: Other ML14064A3692014-03-11011 March 2014 University of Maryland, College Park Request for Additional Information Review of the Emergency Plan for License Renewal for the University of Maryland Training Reactor Project stage: RAI ML14141A6302014-06-0202 June 2014 University of Maryland, College Park Request for Additional Information Financial Update for License Renewal for the University of Maryland, College Park Training Reactor Project stage: RAI ML14176A0782014-06-18018 June 2014 University of Maryland Training Reactor - Report on AR-41 Mitigation Project stage: Request 2011-12-01
[Table View] |
Text
September 25, 2014 Dr. Timothy W. Koeth, Director Nuclear Reactor and Radiation Facilities Chemical and Nuclear Engineering Building 090 University of Maryland College Park, MD 20742
SUBJECT:
UNIVERSITY OF MARYLAND - REQUEST FOR ADDITIONAL INFORMATION RE: REVIEW OF THE ARGON-41 RADIOLOGICAL DOSE ASSESSMENT FOR LICENSE RENEWAL OF THE MARYLAND UNIVERSITY TRAINING REACTOR (TAC NO. ME1592)
Dear Dr. Koeth:
The U. S. Nuclear Regulatory Commission (NRC) is continuing its review of your application for the renewal of Facility Operating License No. R-70, for the Maryland University Training Reactor, dated May 12, 2000, (a redacted version of the application, including the safety analysis report, is available on the NRCs public Web site at www.nrc.gov under Agencywide Documents Access and Management System (ADAMS) Accession No. ML003718746), as supplemented. During our review of your letter dated June 18, 2014 (ADAMS Accession No. ML14176A078), questions have arisen for which we require additional information and clarification. The enclosed request for additional information (RAI) identifies the additional information needed to complete our review. We request responses to the enclosed RAI within 30 days from the date of this letter.
In accordance with 10 CFR 50.30(b), you must execute your response in a signed original document under oath or affirmation. Your response must be submitted in accordance with 10 CFR 50.4, Written communications. Information included in your response that is considered sensitive or proprietary, that you seek to have withheld from the public, must be marked in accordance with 10 CFR 2.390, Public inspections, exemptions, requests for withholding. Any information related to security should be submitted in accordance with 10 CFR 73.21, Protection of Safeguards Information: Performance requirements. Following receipt of the additional information, we will continue our evaluation of your renewal request.
If you have any questions, or need additional time to respond to this request, contact Eben Allen at 301-415-4264 or by electronic mail at Eben.Allen@nrc.gov.
Sincerely,
/RA/
Geoffrey A. Wertz, Project Manager Research and Test Reactors Licensing Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-166
Enclosure:
Request for Additional Information cc: See next page
ML14266A658 NRR-088 OFFICE PRLB: PM PRLB : PM PRPB: LA PRLB: BC PRLB : PM NAME EAllen GWertz CHawes for PBlechman AAdams GWertz DATE 9/24/14 9/23/2014 9/25/14 9/25/14 9/25/14
University of Maryland Docket No. 50-166 cc:
Director, Dept. of Natural Resources Power Plant Siting Program Energy & Coastal Zone Administration Tawes State Office Building Annapolis, MD 21401 Mr. Roland G. Fletcher, Program Manager IV Radiological Health Program Maryland Department of Environment 1800 Washington Blvd., Suite 750 Baltimore, MD 21230-1718 Mr. Vincent G. Adams Facility Coordinator Chemical and Nuclear Engineering Building 090 University of Maryland College Park, MD 20742 Mary J. Dorman Radiation Safety Officer Department of Environmental Safety 3115 Chesapeake Building 338 University of Maryland College Park, MD 20742 Professor Robert Briber Department of Materials Science and Engineering University of Maryland College Park, MD 20742-2115 Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611
OFFICE OF NUCLEAR REACTOR REGULATION REQUEST FOR ADDITIONAL INFORMATION REGARDING LICENSE RENEWAL FOR THE MARYLAND UNIVERSITY TRAINING REACTOR LICENSE NO. R-70; DOCKET NO. 50-166 The U. S. Nuclear Regulatory Commission (NRC) is continuing its review of your application for renewal of Facility Operating License No. R-70, for the MUTR, dated May 12, 2000, (ADAMS Accession No. ML003718746), as supplemented. During our review of your letter dated June 18, 2014 (ML14176A078), questions have arisen for which we require additional information and clarification. The RAI identifies the additional information needed to complete our review.
We request that you provide responses to the enclosed RAI within 30 days from the date of this letter.
- 1.
NUREG-1537, Part 1, Section 11.1.1.1 Airborne Radiation Sources, provides detailed guidance on dose assessment associated with the production of Argon-41 (Ar-41) in non-power reactor facilities. This guidance requests that the specific source locations, source release rates, concentrations in occupied areas, personnel doses and dose rates, release points from the restricted area, diffusion and dispersion in unrestricted areas, predicted concentrations in unrestricted areas and potential dose rates and annual doses for both radiation workers (occupational) and members of the public (public) should be provided. The NRC staff review found specific details concerning this information to be lacking from the MUTR SAR and the letter dated June 18, 2014. The following information is requested:
a)
Provide the leakage flow rate of Ar-41 from the restricted area to any outlying areas (hallways, classrooms, etc) and the environment. Provide any calculations, assumptions, and/or conservatism used to support the flow rate determination.
b)
Provide a description of the release point(s) and any flow paths for the Ar-41 effluent from the restricted area to any unrestricted area(s).
c)
Provide the potential radiological dose to any members of the public from effluents that could leak from the MUTR confinement. Provide an analysis of the maximum exposure to an individual at the nearest unrestricted location such as permanent residence, classroom, campus dormitory, fence line, or other special interest space. Provide any assumptions used for this determination.
d)
In the letter dated June 18, 2014, MUTR stated the highest concentrations of Ar-41 exist on the experimental floor. Describe how access is controlled to this area during reactor operations. Describe how radiation monitoring is accomplished to provide protection to a worker from an unanticipated Ar-41 exposure when experimental facilities are being utilized or in the event of a failure such as the thermal column seal.