Category:E-Mail
MONTHYEARML24191A4232024-07-0303 July 2024 RAI2 NRC Response to Fws ESA Crystal River Unit 3 LTP ML24170A9242024-06-18018 June 2024 024-0023697 Crystal River License Termination Plan Unit 3 ML24190A1382024-06-18018 June 2024 Supplement to NRC Request for Concurrence with ESA Determinations for Crystal River Unit 3 LTP ML24143A0242024-05-20020 May 2024 Draft EA for Crystal River Unit 3 Opportunity for Flhealth Review and Comment ML24143A0132024-05-20020 May 2024 Achp Response for Crystal River Unit 3 (Achp Project No. 020794) ML24143A0212024-05-20020 May 2024 Shpo Response to Initiate Section 106 Consultation for Crystal River Unit 3 ML24120A3312024-04-24024 April 2024 Seminole Tribe of Florida Email - Initiation ML24025A0952024-01-24024 January 2024 Clarifications Related to the NRC Staff'S EA for Crystal River ML23180A0562023-06-13013 June 2023 ADP-CR3, Crystal River Unit 3 Email from J. Jernigan to Tim Barvitskie Confirmation That Enclosure 22 Radiological Groundwater Characterization Report ML21117A2902021-04-26026 April 2021 Acceptance of License Amendment Request Related to the ISFSI-Only Physical Securityplan ML21096A0432021-04-0505 April 2021 Acceptance of License Amendment Request Related to the ISFSI-Only Emergency Plan ML19344C8052019-11-12012 November 2019 Response from NEIMA Local Community Advisory Board Questionnaire 11-12-2019 H Danenhower ML19310D8602019-10-24024 October 2019 E-Mail Dated October 24, 2019, from Mark Vansicklen, Duke Energy Florida, to John Hickman, NRC, Providing Background Information for the Crystal River Partial Site Release Request ML19344C7872019-10-0303 October 2019 Response from NEIMA Local Community Advisory Board Questionnaire 10-03-2019 D Taylor ML19310D8212019-09-13013 September 2019 E-Mail Dated September 13, 2019, from John Hickman, NRC, to Mark Vansicklen, Duke Energy Florida, Requesting Background Information for the Crystal River Partial Site Release Request ML19130A2082019-05-0808 May 2019 Email - NRC Email to FEMA Dated May 8, 2019: NRC Response to Comment on FEMA Review of Proposed Changes to DBNPS Emergency Plan for Permanently Defueled Condition ML19071A0662019-03-0606 March 2019 E-Mail Dated 3/6/2019 from John Hickman, NRC, to Phyllis Dixon, Duke Energy Florida, LLC, Regarding NRC Acceptance Review of a Request to Revise the ISFSI Only Emergency Plan for Crystal River Unit 3 ML19070A3112019-03-0606 March 2019 Document Title or Accession No. E-Mail Dated 3/6/2019 from John Hickman, NRC, to Phyllis Dixon, Duke Energy Florida, LLC, Regarding NRC Acceptance Review of Partial Site Release Request for Crystal River Unit 3 ML18263A1462018-09-11011 September 2018 NRR E-mail Capture - Logbook Entry: 09/11/2018 a Kemp'S Ridley Sea Turtle (Federal Endangered Species) Carcass Was Recovered from the Crystal River Energy Complex Unit 2 Fossil Unit ML16054A2402015-12-10010 December 2015 E-44108 Attachment 10 E-mail from Steven Edwards (Due Energy) to Don Shaw (Areva) for Brunswick Nuclear Plant, Oconee Nuclear Station, and Robinson Nuclear Plant ML15176A2692015-06-25025 June 2015 NRR E-mail Capture - NRC Acceptance Review for LAR #317 Regarding Changes in Managment Titles ML15043A1042015-02-0505 February 2015 NRR E-mail Capture - Mf Crystal River TAC ML15015A6722015-01-15015 January 2015 NRR E-mail Capture - NRC Acceptance Review for LAR - Application for Order Approving Transfer of License and for Conforming License Amendment ML14344A9992014-12-0909 December 2014 NRR E-mail Capture - Severe Weather Exemption ML14258A7432014-09-0505 September 2014 NRR E-mail Capture - FW: Comparison of Crystal River'S Exemption Secy Paper with Kewaunee'S ML14290A1992014-08-27027 August 2014 NRR E-mail Capture - Draft RAIs for Ep/Eal LAR ML14163A2512014-06-0303 June 2014 NRR E-mail Capture - Request for Additional Information - Exemption for Conducting Annual force-on-force Exercises ML14153A0842014-05-29029 May 2014 NRR E-mail Capture - Logbook Entry: 05/29/2014 ML14153A6912014-05-21021 May 2014 NRR E-mail Capture - Request for Additional Information - Decommissionign Trust Fund Exemption Request ML14132A2052014-05-0909 May 2014 NRR E-mail Capture - MF3089 - Defueled TS Amendment Request for Additrional Information ML14114A2792014-04-10010 April 2014 NRR E-mail Capture - MF3089 Defueled TS Request for Additional Information ML14113A3632014-04-10010 April 2014 NRR E-mail Capture - MF3415/MF2981 RAI on EP Exemptions, EAL Scheme Change and E Plan Amendment ML14118A2872014-02-20020 February 2014 NRR E-mail Capture - Request for Additional Information: Exemptions to the Radiological Emergency Plan Requirements ML14045A0012014-02-12012 February 2014 NRR E-mail Capture - RAI: Adminstrative Controls ML14031A1752014-01-27027 January 2014 NRR E-mail Capture - CR3 Certified Fuel Handler Training and Retraining Program Approval - RAI Request ML14017A0772014-01-16016 January 2014 NRR E-mail Capture - Brunswick 1 and 2, Crystal River Unit 3, Harris Unit 1, and Robinson Unit 2 - Acceptance for Review of License Amendment Request for Cyber Security Plan Implementaion Milestone 8 (TAC Nos. MF3263 - MF3267) ML14027A0332013-12-16016 December 2013 NRR E-mail Capture - Eplan and EAL Scheme Change Request for Additional Information (LAR #315) ML13336A9112013-12-0202 December 2013 NRR E-mail Capture - Periodic Update to the Crystal River 3 Containment Petition ML13198A1422013-07-17017 July 2013 NRR E-mail Capture - Draft RAI - Request to Amend Section 5.0 of the CR-3 Technical Specifications (MF1504) ML13157A2062013-05-31031 May 2013 NRR E-mail Capture - Logbook Entry: 5/31/2013 ML13155A2062013-05-29029 May 2013 NRR E-mail Capture - Petition Status Update - Containment for Crystal River ML13120A0412013-04-29029 April 2013 NRR E-mail Capture - Status Update for Petition on Crystal River 3 ML13095A4002013-04-0505 April 2013 E-mail - Acceptance of Requested Licensing Action Change of Licensee Name ML13052A2402013-02-0808 February 2013 LTR-13-0131 - E-mail Tom Gurdziel Concerns Crystal River, Unit 3 ML13015A2832013-01-14014 January 2013 NRR E-mail Capture - Status of 10 CFR 2.206 Petition Related to Crystal River 3 ML13011A1482013-01-10010 January 2013 NRR E-mail Capture - CR-3 EPU LAR - Additional RAI from Eeeb (ME6527) ML12304A0682012-10-26026 October 2012 NRR E-mail Capture - RAIs Regarding Crystal River 30-day Report for ECCS Model Changes Pursuant to 10 CFR 50.46 Requirements (ME8408) ML12297A3922012-10-23023 October 2012 NRR E-mail Capture - Draft Bypass Test Plan ML12268A3592012-09-24024 September 2012 NRR E-mail Capture - Acceptance Review for LAR Regarding Cyber Security Plan Implementation Schedule Milestones ML12208A0142012-07-25025 July 2012 NRR E-mail Capture - State Consultation 2024-07-03
[Table view] |
Text
NRR-PMDAPEm Resource From: Gratton, Christopher Sent: Wednesday, May 21, 2014 2:53 PM To: Westcott, Daniel (Daniel.Westcott@duke-energy.com)
Cc: Broaddus, Doug
Subject:
Request for additional information - Decommissionign Trust Fund Exemption request Follow Up Flag: Follow up Flag Status: Flagged Mr. Westcott, By letter dated March 28, 2014 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML14098A037), Duke Energy Florida, Inc. (DEF, or the licensee) submitted an exemption request regarding Crystal River Nuclear Plant Unit 3 (CR-3) Facility Operating License. The proposed exemption would allow the CR-3 decommissioning trust funds (DTFs) held by DEF and the co-owners to be used for spent fuel management and site restoration activities. DEF also requested, on behalf of itself and the CR-3 co-owners, pursuant to 10 CFR 50.12, an exemption from 10 CFR 50.75(h)(2) to allow CR-3 DTF disbursements for spent fuel management and site restoration activities to be made without prior notice, similar to withdrawals in accordance with 10 CFR 50.82(a)(8).
The Nuclear Regulatory Commission (NRC) staff has performed a preliminary review of the request and found that some further information is needed to complete the staffs review. The staffs draft information request is included below. The NRC considers that timely responses to request for additional information (RAIs) help ensure sufficient time is available for the NRC staff review and contribute toward the NRCs goal of efficient and effective use of staff resources.
Please provide your response by July 3, 2014.
You may request a conference call to discuss the contents of this draft RAI with the NRC staff, including any change to the proposed schedule. Please send me an email if you do not need a conference call to clarify the draft RAI. If you do not require a call to clarify the draft RAI, the information request will be considered final.
Respectfully, Christopher Gratton Sr. Project Manager PM Crystal River Nuclear Generating Plant NRR/DORL/LPL 4-2 and Decommissioning Transition Branch 301-415-1055 Mail Stop O-8G9a Christopher.Gratton@nrc.gov REQUEST FOR ADDITIONAL INFORMATION OFFICE OF NUCLEAR REACTOR REGULATION CRYSTAL RIVER UNIT 3 DOCKET NO. 50-302
Background
The U.S. Nuclear Regulatory Commission (NRC) staff is currently reviewing Duke Energy Floridas (DEF)
Crystal River Unit 3 (CR-3) exemption request from Title 10 of the Code of Federal Regulations (CFR) Part 50, Sections 50.82(a)(8)(i)(A) and 10 CFR 50.75(h)(2), dated March 28, 2014 (Agencywide Documents Access and Management System (ADAMS) 1
Accession No. ML14098A037). The staff determined the following information is needed:
Request for Additional Information #1:
Florida Public Service Commission (FPSC) Order No. PSC-13-0452-FOF-EI permits DEF to allocate its decommissioning trust fund among the three categories of license termination, spent fuel management, and site restoration. However, when requested by the licensee, the FPSC did not issue a declaratory statement prohibiting spent fuel management and site restoration funds to be used for license termination costs without FPSC approval. By letter dated March 31, 2014, DEF submitted its Annual Decommissioning and Irradiated Fuel Management Financial Status Report for 2013 (ADAMS Accession No. ML14089A039). In that report, DEF indicated that 62.86%, or $520,973,000, of the decommissioning trust fund is designated for radiological decommissioning. However, in the exemption request, DEF performed a cash flow analysis based on 100% of the decommissioning trust fund, or $824,788,000, and on expenses unrelated to decommissioning as defined in 10 CFR 50.2.
According to 10 CFR 50.82(8)(i)(A), Decommissioning trust funds may be used by licensees if the withdrawals are for expenses for legitimate decommissioning activities consistent with the definition of decommissioning in §50.2. It is not clear to the NRC staff what portion of the nuclear decommissioning trust fund is meant for decommissioning as defined in 10 CFR 50.2.
Please provide the amount in the nuclear decommissioning trust fund dedicated for decommissioning, as defined in 10 CFR 50.2, and provide an updated cash flow analysis.
2
Hearing Identifier: NRR_PMDA Email Number: 1327 Mail Envelope Properties (Christopher.Gratton@nrc.gov20140521145300)
Subject:
Request for additional information - Decommissionign Trust Fund Exemption request Sent Date: 5/21/2014 2:53:17 PM Received Date: 5/21/2014 2:53:00 PM From: Gratton, Christopher Created By: Christopher.Gratton@nrc.gov Recipients:
"Broaddus, Doug" <Doug.Broaddus@nrc.gov>
Tracking Status: None "Westcott, Daniel (Daniel.Westcott@duke-energy.com)" <Daniel.Westcott@duke-energy.com>
Tracking Status: None Post Office:
Files Size Date & Time MESSAGE 4150 5/21/2014 2:53:00 PM Options Priority: Standard Return Notification: No Reply Requested: No Sensitivity: Normal Expiration Date:
Recipients Received: Follow up