ML24054A646

From kanterella
Jump to navigation Jump to search

Request for RAI Extension Related to the Crystal River License Termination Plan
ML24054A646
Person / Time
Site: Crystal River Duke Energy icon.png
Issue date: 02/29/2024
From: Jernigan J
NorthStar Group Services
To: Barvitskie T, Jack Parrott
Reactor Decommissioning Branch
Shared Package
ML24054A541 List:
References
EPID L-2022-LLA-0194
Download: ML24054A646 (1)


Text

From: Jernigan, John To: Tim Barvitskie; Jack Parrott

Subject:

[External_Sender] Crystal River 3 LTP Challenges Date: Wednesday, February 21, 2024 3:44:47 PM

Gentlemen, We have encountered issues with received lab analysis information. Within the ground water results, we received trace indicators less than MDC for hard to detect ROCs, but they were greater than their Critical Limits. As we have encountered from time to time, we believe the lab results are inaccurate.

Insufficient sample quantities were present at the lab for further analysis, so we have resampled and provided these samples to our lab for reanalysis, which we have requested expedited results for. Our methodology we have documented within our LTP accounts for these results being less than their critical limits. We are also still waiting on soil results to be received for characterization efforts around the exterior of the power block to demonstrate the absence of contamination at depth. We anticipate receiving the soil analysis by the end of next week and we will finalize the calculations and table in their associated reports. We also have our newly developed DCGLs undergoing QC review, along with putting Survey Units back into our LTP chapter.

With all of the items mentioned above, Crystal River 3 requests an extension for the response to our Request for Additional Information by an additional 30 days. As discussed, our expected response is dated for 2/29/24. Please provide an extension granting the site until 3/29/24 for submittal of the RAIs. Thank you.

Regards, John Jernigan D&D Licensing Manager Northstar Group Services, Inc Crystal River Unit 3 352-342-0792

Confidentiality Note: This e-mail, and any attachment to it, contains privileged and confidential information intended only for the use of the individual(s) or entity named on the e-mail. If the reader of this e-mail is not the intended recipient, or the employee or agent responsible for delivering it to the intended recipient, you are hereby notified that reading it is strictly prohibited. If you have received this e-mail in error, please immediately return it to the sender and delete it from your system. Thank you.