MONTHYEARML24312A2262024-11-0606 November 2024 Letter from C. Nelson, Michigan SHPO Regarding Palisades Nuclear Plant Architectural Survey ML24292A1572024-11-0505 November 2024 Ape Notification to Burt Lake Band Palisades ML24310A0142024-11-0505 November 2024 Ape Notification to Mackinac Bands of Chippewa Palisades ML24310A0132024-11-0505 November 2024 Ape Notification to Grand River Bands of Ottawa Indians Palisades ML24309A2032024-11-0404 November 2024 Ape Notification to Ottawa Tribe of Oklahoma Palisades ML24309A1972024-11-0404 November 2024 Ape Notification to Little Traverse Bay Bands of Odawa Indians Palisades ML24309A1982024-11-0404 November 2024 Ape Notification to Match E Be Nash She Wish Band of Pottawatomi Indians Palisades ML24309A1872024-11-0404 November 2024 Ape Notification to Grand Portage Band of Lake Superior Chippewa Palisades ML24309A2072024-11-0404 November 2024 Ape Notification to Quechan Tribe of the Fort Yuma Indian Reservation Palisades ML24309A1832024-11-0404 November 2024 Ape Notification to Bois Forte Band of the Minnesota Chippewa Tribe Palisades ML24309A2122024-11-0404 November 2024 Ape Notification to Sault Ste. Marie Tribe of Chippewa Indians Palisades ML24309A2042024-11-0404 November 2024 Ape Notification to Pokagon Band of Potawatomi Indians Palisades ML24292A0492024-11-0404 November 2024 Ape Notification to Bad River Band of the Lake Superior Tribe of Chippewa Indians Palisades ML24309A1932024-11-0404 November 2024 Ape Notification to Leech Lake Band of Ojibwe Palisades ML24309A2012024-11-0404 November 2024 Ape Notification to Mille Lacs Band of Ojibwe Palisades ML24309A1922024-11-0404 November 2024 Ape Notification to Lac Vieux Desert Band of Lk Superior Chippewa Indians Palisades ML24309A1892024-11-0404 November 2024 Ape Notification to Hannahville Indian Community Palisades ML24309A2002024-11-0404 November 2024 Ape Notification to Miami Tribe of Oklahoma Palisades ML24309A1952024-11-0404 November 2024 Ape Notification to Little River Band of Ottawa Indians Palisades ML24309A2112024-11-0404 November 2024 Ape Notification to Saint Croix Chippewa Indians of Wisconsin Palisades ML24309A1902024-11-0404 November 2024 Ape Notification to Lac Courte Oreilles Band of Lake Superior Chippewa Palisades ML24309A2022024-11-0404 November 2024 Ape Notification to Nottawaseppi Huron Band of the Potawatomi Palisades ML24309A1852024-11-0404 November 2024 Ape Notification to Citizen Potawatomi Nation Palisades ML24309A2142024-11-0404 November 2024 Ape Notification to White Earth Band of Minnesota Chippewa Tribe Palisades ML24309A2092024-11-0404 November 2024 Ape Notification to Red Lake Band of Chippewa Indians Palisades ML24309A1862024-11-0404 November 2024 Ape Notification to Forest County Potawatomi Community Palisades ML24309A1822024-11-0404 November 2024 Ape Notification to Bay Mills Indian Community Palisades ML24309A2052024-11-0404 November 2024 Ape Notification to Prairie Band Potawatomi Nation Palisades ML24309A2102024-11-0404 November 2024 Ape Notification to Saginaw Chippewa Indian Tribe of Michigan Palisades ML24309A2082024-11-0404 November 2024 Ape Notification to Red Cliff Band of Lake Superior Chippewa Indians Palisades ML24309A1992024-11-0404 November 2024 Ape Notification to Menominee Indian Tribe of Wisconsin Palisades ML24292A0072024-11-0404 November 2024 Ape Notification to Achp Palisades ML24309A1882024-11-0404 November 2024 Ape Notification to Grand Traverse Band of Ottawa and Chippewa Indians Palisades ML24309A1842024-11-0404 November 2024 Ape Notification to Chippewa Cree Indians of the Rocky Boys Reservation of Montana Palisades ML24309A1912024-11-0404 November 2024 Ape Notification to Lac Du Flambeau Band of Lake Superior Chippewa Indians Palisades ML24309A2132024-11-0404 November 2024 Ape Notification to Turtle Mountain Band of Chippewa Indians Palisades ML24309A2062024-11-0404 November 2024 Ape Notification to Prairie Island Indian Community Palisades PNP 2024-014, Request for USNRC to Rescind Approved Exemption Requests for 140.11(a)(4) and 50.54(w)(1), Reduction of Insurances2024-10-0909 October 2024 Request for USNRC to Rescind Approved Exemption Requests for 140.11(a)(4) and 50.54(w)(1), Reduction of Insurances PNP 2024-037, Response to Requests for Additional Information Regarding the Proposed Reauthorization of Power Operations Under Renewed Facility Operating License Number DPR-0202024-10-0404 October 2024 Response to Requests for Additional Information Regarding the Proposed Reauthorization of Power Operations Under Renewed Facility Operating License Number DPR-020 ML24267A2962024-10-0101 October 2024 Summary of Conference Call Regarding Steam Generator Tube Inspections ML24263A1712024-09-20020 September 2024 Environmental Request for Additional Information ML24240A1692024-09-18018 September 2024 Cy 2023 Summary of Decommissioning Trust Fund Status ML24219A4202024-09-12012 September 2024 Change in Estimated Hours and Review Schedule for Licensing Actions Submitted to Support Resumption of Power Operations (Epids L-2023-LLE-0025, L-2023-LLM-0005, L-2023-LLA-0174, L-2024-LLA-0013, L-2024-LLA-0060, L-2024-LLA-0071) IR 05000255/20244022024-09-0606 September 2024 Public: Palisades Nuclear Plant - Decommissioning Security Inspection Report 05000255/2024402 PNP 2024-029, Notice of Payroll Transition at Palisades Nuclear Plant2024-08-15015 August 2024 Notice of Payroll Transition at Palisades Nuclear Plant IR 05000255/20240022024-08-0909 August 2024 NRC Inspection Report No. 05000255/2024002 PNP 2024-030, Update Report for Holtec Decommissioning International Fleet Decommissioning Quality Assurance Program Rev. 3 and Palisades Transitioning Quality Assurance Plan, Rev 02024-08-0202 August 2024 Update Report for Holtec Decommissioning International Fleet Decommissioning Quality Assurance Program Rev. 3 and Palisades Transitioning Quality Assurance Plan, Rev 0 PNP 2024-032, Supplement to License Amendment Request to Revise Selected Permanently Defueled Technical Specifications Administrative Controls to Support Resumption of Power Operations2024-07-31031 July 2024 Supplement to License Amendment Request to Revise Selected Permanently Defueled Technical Specifications Administrative Controls to Support Resumption of Power Operations ML24206A0572024-07-25025 July 2024 PRM-50-125 - Letter to Alan Blind; Docketing of Petition for Rulemaking and Sufficiency Review Status (10 CFR Part 50) PNP 2024-033, Response to Request for Additional Information - License Amendment Request to Revise the Palisades Nuclear Plant Site Emergency Plan to Support Resumption of Power Operations2024-07-24024 July 2024 Response to Request for Additional Information - License Amendment Request to Revise the Palisades Nuclear Plant Site Emergency Plan to Support Resumption of Power Operations 2024-09-06
[Table view] Category:License-Application for Facility Operating License (Amend/Renewal) DKT 50
MONTHYEARPNP 2024-027, Supplement to License Amendment Request to Revise Renewed Facility Operating License and Permanently Defueled Technical Specifications to Support Resumption of Power Operations2024-07-0909 July 2024 Supplement to License Amendment Request to Revise Renewed Facility Operating License and Permanently Defueled Technical Specifications to Support Resumption of Power Operations PNP 2024-003, License Amendment Request to Approve the Biasi Critical Heat Flux (CHF) Correlation for Use with the Palisades Main Steam Line Break (MSLB) Analysis2024-05-24024 May 2024 License Amendment Request to Approve the Biasi Critical Heat Flux (CHF) Correlation for Use with the Palisades Main Steam Line Break (MSLB) Analysis PNP 2024-005, License Amendment Request to Revise the Palisades Nuclear Plant Site Emergency Plan to Support Resumption of Power Operations2024-05-0101 May 2024 License Amendment Request to Revise the Palisades Nuclear Plant Site Emergency Plan to Support Resumption of Power Operations PNP 2024-001, License Amendment Request to Revise Selected Permanently Defueled Technical Specifications Administrative Controls to Support Resumption of Power Operations2024-02-0909 February 2024 License Amendment Request to Revise Selected Permanently Defueled Technical Specifications Administrative Controls to Support Resumption of Power Operations PNP 2023-030, License Amendment Request to Revise Renewed Facility Operating License and Permanently Defueled Technical Specifications to Support Resumption of Power Operations2023-12-14014 December 2023 License Amendment Request to Revise Renewed Facility Operating License and Permanently Defueled Technical Specifications to Support Resumption of Power Operations PNP 2022-031, License Amendment Request, Revise License Condition to Eliminate Cyber Security Plan Requirements2022-09-14014 September 2022 License Amendment Request, Revise License Condition to Eliminate Cyber Security Plan Requirements PNP 2022-016, License Amendment Request: Proposed Permanently Defueled Emergency Plan and Permanently Defueled Emergency Action Level Scheme2022-07-12012 July 2022 License Amendment Request: Proposed Permanently Defueled Emergency Plan and Permanently Defueled Emergency Action Level Scheme ML21152A1112021-06-0101 June 2021 Proposed Changes (mark-up) to Palisades Plant - Appendix a Technical Specifications, and Appendix B Environmental Protection Plan Pages ML21152A1122021-06-0101 June 2021 Page Change Instructions and Retyped Pages for the Palisades Plant Appendix a Permanently Defueled Technical Specifications and Appendix B Environmental Protection Plan ML21152A1132021-06-0101 June 2021 Palisade Nuclear Plant - Proposed Technical Specifications Bases Changes ML21152A1102021-06-0101 June 2021 Evaluation of the Proposed Changes PNP 2020-042, and Big Rock Point Application for Order Consenting to Transfers of Control of Licenses and Approving Conforming License Amendments2020-12-23023 December 2020 and Big Rock Point Application for Order Consenting to Transfers of Control of Licenses and Approving Conforming License Amendments RS-19-040, Application to Adopt TSTF-563, Revise Instrument Testing Definitions to Incorporate the Surveillance Frequency Control Program2019-06-25025 June 2019 Application to Adopt TSTF-563, Revise Instrument Testing Definitions to Incorporate the Surveillance Frequency Control Program ML19149A3042019-05-28028 May 2019 Enclosure Attachment 1 (Continued) to Pnp 2019-028: Operating License Page Change Instructions and Retyped Renewed Facility Operating License Pages ML19149A3022019-05-28028 May 2019 Enclosure to Pnp 2019-028: Response to Request for Additional Information - License Amendment Request to Revise Existing Facility Operating License Conditions Regarding NFPA 805 Modifications ML19149A3032019-05-28028 May 2019 Enclosure Attachment 1 to Pnp 2019-028: Renewed Facility Operating License Page Markups PNP 2019-007, License Amendment Request to Change the Full Compliance Implementation Date for the Fire Protection Program Transition License Condition for Required Modifications2019-03-0808 March 2019 License Amendment Request to Change the Full Compliance Implementation Date for the Fire Protection Program Transition License Condition for Required Modifications CNRO-2019-00003, Application to Revise Technical Specifications to Adopt TSTF-529 11 Clarify Use and Application Rules, 11 Revision 42019-01-31031 January 2019 Application to Revise Technical Specifications to Adopt TSTF-529 11 Clarify Use and Application Rules, 11 Revision 4 PNP 2018-040, License Amendment Request to Revise Existing Facility Operating License Conditions Regarding NFPA 805 Modifications - Proposed Renewed Facility Operating License Page Changes (Markup)2018-11-0101 November 2018 License Amendment Request to Revise Existing Facility Operating License Conditions Regarding NFPA 805 Modifications - Proposed Renewed Facility Operating License Page Changes (Markup) ML18305B3222018-11-0101 November 2018 License Amendment Request to Revise Existing Facility Operating License Conditions Regarding NFPA 805 Modifications - Proposed Operating License Change ML18305B3212018-11-0101 November 2018 License Amendment Request to Revise Existing Facility Operating License Conditions Regarding NFPA 805 Modifications ML18270A3232018-09-27027 September 2018 Attachment 2: Probabilistic Risk Assessment Technical Adequacy ML18270A3262018-09-27027 September 2018 Attachment 5: Proposed Technical Specification Bases Changes ML18270A3252018-09-27027 September 2018 Attachment 4: Page Change Instructions and Revised Pages, and Appendix a Technical Specifications ML18270A3222018-09-27027 September 2018 Attachment 1: Description and Evaluation of Technical Specifications Changes ML18270A3282018-09-27027 September 2018 Attachment 7: Traveler TSTF-425 Versus Pnp RFOL SR Applicability Cross Reference Table ML18270A3272018-09-27027 September 2018 Attachment 6: No Significant Hazards Consideration PNP 2018-025, License Amendment Request - Application to Revise Technical Specifications to Adopt TSTF-425, Revision 3, Relocate Surveillance Frequencies to Licensee Control- Risk Informed Technical Specification Task Force (RITSTF) Initiative 5b.2018-09-27027 September 2018 License Amendment Request - Application to Revise Technical Specifications to Adopt TSTF-425, Revision 3, Relocate Surveillance Frequencies to Licensee Control- Risk Informed Technical Specification Task Force (RITSTF) Initiative 5b. ML18270A3242018-09-27027 September 2018 Attachment 3: Proposed Changes and Appendix a Technical Specifications Pages ML18152A9292018-05-30030 May 2018 License Amendment Request to Revise Emergency Diesel Generator Degraded Voltage Surveillance Requirement PNP 2018-004, Supplement to License Amendment Request to Change the Full Compliance Implementation Date for the Fire Protection Program Transition License Condition for Required Modifications2018-01-24024 January 2018 Supplement to License Amendment Request to Change the Full Compliance Implementation Date for the Fire Protection Program Transition License Condition for Required Modifications PNP 2017-066, License Amendment Request to Change the Full Compliance Implementation Date for the Fire Protection Program Transition License Condition for Required Modifications2017-11-0101 November 2017 License Amendment Request to Change the Full Compliance Implementation Date for the Fire Protection Program Transition License Condition for Required Modifications PNP 2017-059, License Amendment Request Supplement - Cyber Security Plan Implementation Schedule2017-10-17017 October 2017 License Amendment Request Supplement - Cyber Security Plan Implementation Schedule PNP 2017-035, License Amendment Request - Administrative Controls for a Permanently Defueled Condition2017-07-27027 July 2017 License Amendment Request - Administrative Controls for a Permanently Defueled Condition PNP 2017-007, License Amendment Request, Cyber Security Plan Implementation Schedule2017-03-30030 March 2017 License Amendment Request, Cyber Security Plan Implementation Schedule PNP 2016-046, License Amendment Request for Editorial and Administrative Changes to Technical Specifications2016-11-0909 November 2016 License Amendment Request for Editorial and Administrative Changes to Technical Specifications PNP 2016-049, License Amendment Request: Control Rod Drive Exercise Surveillance2016-08-22022 August 2016 License Amendment Request: Control Rod Drive Exercise Surveillance PNP 2016-005, License Amendment Request - Application to Revise Technical Specifications to Adopt TSTF-545, Revision 3, TS Inservice Testing Program Removal and Clarify SR Usage Rule Application to Section 5.5 Testing.2016-07-11011 July 2016 License Amendment Request - Application to Revise Technical Specifications to Adopt TSTF-545, Revision 3, TS Inservice Testing Program Removal and Clarify SR Usage Rule Application to Section 5.5 Testing. PNP 2016-001, License Amendment Request - Revision to the Requirements for Steam Generator Tube Inspections and Repair Criteria in the Cold Leg Tube Sheet Region2016-03-0303 March 2016 License Amendment Request - Revision to the Requirements for Steam Generator Tube Inspections and Repair Criteria in the Cold Leg Tube Sheet Region PNP 2015-035, License Amendment Request - Cyber Security Plan Implementation Schedule2015-06-11011 June 2015 License Amendment Request - Cyber Security Plan Implementation Schedule PNP 2014-111, Revised License Condition - License Amendment Request to Adopt NFPA 805 Performance-Based Standard for Fire Protection for Light Water Reactors2014-12-18018 December 2014 Revised License Condition - License Amendment Request to Adopt NFPA 805 Performance-Based Standard for Fire Protection for Light Water Reactors PNP 2014-091, Supplement to License Amendment Request to Revise Emergency Response Organization Staff Augmentation Response Times2014-12-0909 December 2014 Supplement to License Amendment Request to Revise Emergency Response Organization Staff Augmentation Response Times ML14237A1442014-12-0808 December 2014 Issuance of Amendment Cyber Security Plan Implementation Schedule PNP 2014-049, License Amendment Request to Implement 10 CFR 50.61 a, Alternate Fracture Toughness Requirements for Protection Against Pressurized Thermal Shock Events.2014-07-29029 July 2014 License Amendment Request to Implement 10 CFR 50.61 a, Alternate Fracture Toughness Requirements for Protection Against Pressurized Thermal Shock Events. ML14211A5252014-07-29029 July 2014 WCAP-17628-NP, Revision 1, Palisades, Alternate Pressurized Thermal Shock (PTS) Rule Evaluation. PNP 2014-042, License Amendment Request - Application to Revise Technical Specifications to Adopt TSTF-426, Revise or Add Actions to Preclude Into LCO 3.0.3 - RITSTF Initiatives 6b & 6c, Using the Consolidated Line Item Improvement Process2014-06-11011 June 2014 License Amendment Request - Application to Revise Technical Specifications to Adopt TSTF-426, Revise or Add Actions to Preclude Into LCO 3.0.3 - RITSTF Initiatives 6b & 6c, Using the Consolidated Line Item Improvement Process PNP 2013-086, License Amendment Request - Cyber Security Plan Implementation Schedule2013-12-30030 December 2013 License Amendment Request - Cyber Security Plan Implementation Schedule PNP 2013-044, License Amendment Request to Revise Emergency Response Organization Staff Augmentation Response Times2013-06-25025 June 2013 License Amendment Request to Revise Emergency Response Organization Staff Augmentation Response Times PNP 2012-074, License Amendment Request - Technical Specifications Change to Add LCO 3.0.8 on the Lnoperability of Snubbers2012-09-0606 September 2012 License Amendment Request - Technical Specifications Change to Add LCO 3.0.8 on the Lnoperability of Snubbers PNP 2012-046, License Amendment Request - Cyber Security Plan Implementation Schedule Milestones2012-06-20020 June 2012 License Amendment Request - Cyber Security Plan Implementation Schedule Milestones 2024-07-09
[Table view] Category:Technical Specifications
MONTHYEARML23236A0042023-12-27027 December 2023 Issuance of Amendment 274 Re Changes to Perm Defueled Emergency Plan and Perm Defueled Emergency Action Level Scheme ML22039A1982022-05-13013 May 2022 Issuance of Amendment No. 272 Permanently Defueled Technical Specifications ML21152A1122021-06-0101 June 2021 Page Change Instructions and Retyped Pages for the Palisades Plant Appendix a Permanently Defueled Technical Specifications and Appendix B Environmental Protection Plan ML19175A0422019-09-11011 September 2019 Arkansas Units 1 and 2; Grand Gulf, Unit 1; Indian Point 2 and 3; Palisades; River Bend, Unit 1; Waterford Unit 3 - Issuance of Amendments to Adopt TSTF-529, Clarify Use and Application Rules ML19107A0532019-05-13013 May 2019 Issuance of Amendment No. 268 Regarding Revision to Diesel Generator Undervoltage Start Surveillance Requirement PNP 2019-004, License Amendment Request Resubmittal to Adopt TSTF-425, Revision 3, Relocate Surveillance Frequencies to Licensee Control - Risk Informed Technical Specification Task Force (RITSTF) Initiative 5b2019-03-28028 March 2019 License Amendment Request Resubmittal to Adopt TSTF-425, Revision 3, Relocate Surveillance Frequencies to Licensee Control - Risk Informed Technical Specification Task Force (RITSTF) Initiative 5b ML18346A2872018-12-12012 December 2018 Appendix a to Provisional Operating License DPR-20, Technical Specifications for the Palisades Plant, Consumers Power Company, Docket No 50-255 ML18344A2512018-12-10010 December 2018 Improved Technical Specifications, Volume 5, Chapter 3.0 ML18039A2442018-02-27027 February 2018 Issuance of Amendment License Amendment Request to Change the Full Compliance Implementation Date for the Fire Protection Program Transition License Condition for Required Modifications ML17121A5102017-06-0808 June 2017 Issuance of Amendment License Amendment Request for Editorial and Administrative Changes to Technical Specifications ML16078A0682016-05-0202 May 2016 Issuance of Amendment Cyber Security Plan Implementation Schedule ML15103A0592015-05-18018 May 2015 Issuance of Amendment Adoption of TSTF-426, Revision 5, Revise or Add Actions to Preclude Entry Into Limiting Condition for Operation 3.0.3 - RITSTF Initiatives 6B and 6C. ML15007A1912015-02-27027 February 2015 Issuance of Amendment Regarding Transition to a Risk-Informed, Performance-Based Fire Protection Program in Accordance with 10 CFR 50.48(c) ML14283A2872014-10-22022 October 2014 Issuance of Amendment Application for Technical Specification Change (TSTF-427) to Add Limiting Condition for Operation 3.0.9 Regarding the Unavailability of Barriers Using the Consolidated Line Item Improvement Process PNP 2014-072, 2014 Steam Generator Tube Inspection Report2014-08-0505 August 2014 2014 Steam Generator Tube Inspection Report ML13101A0942013-04-12012 April 2013 Correction to Amendment No. 249 Regarding Change to the Entergy QAPM and Associated Technical Specifications Regarding Staff Qualifications CNRO-2012-00009, Entergy Responses to Request for Additional Information Regarding Changes to the Quality Assurance Program Manual & Associated Plant Technical Specifications Re Staff Qualifications2012-11-20020 November 2012 Entergy Responses to Request for Additional Information Regarding Changes to the Quality Assurance Program Manual & Associated Plant Technical Specifications Re Staff Qualifications PNP 2012-074, License Amendment Request - Technical Specifications Change to Add LCO 3.0.8 on the Lnoperability of Snubbers2012-09-0606 September 2012 License Amendment Request - Technical Specifications Change to Add LCO 3.0.8 on the Lnoperability of Snubbers ML1207400812012-04-23023 April 2012 Issuance of Amendment to Extend the Containment Type a Leak Rate Test Frequency to 15 Years ML1206004152012-03-0202 March 2012 Correction to Amendment No. 244 Regarding Technical Specification Change to Calculated Peak Containment Internal Pressure PNP 2012-005, License Amendment Request - Replacement of Spent Fuel Pool Region 1 Storage Racks2012-02-28028 February 2012 License Amendment Request - Replacement of Spent Fuel Pool Region 1 Storage Racks ML11362A4682012-01-27027 January 2012 License Amendment, Issuance of Amendment No. 246 to Revise TS Sections 3.7.16 and 4.3 Regarding Fuel Storage Criticality PNP 2011-058, License Amendment Request to Revise Calculated Peak Containment Internal Pressure2011-08-16016 August 2011 License Amendment Request to Revise Calculated Peak Containment Internal Pressure ML1115701362011-07-26026 July 2011 License Amendment, Emergency Diesel Generator Fuel Oil and Lube Oil Systems PNP 2011-002, License Amendment Request for Spent Fuel Pool Region I Criticality2011-01-31031 January 2011 License Amendment Request for Spent Fuel Pool Region I Criticality ML1020105792010-07-20020 July 2010 License Amendment Request for Emergency Diesel Generator Fuel Oil and Lube Oil Systems ML0833606192008-11-25025 November 2008 License Amendment Request for Spent Fuel Pool Region I Criticality ML0826801552008-09-22022 September 2008 License Amendment Request Application for Licensee Name Changes ML0824605502008-08-28028 August 2008 License Amendment Request: Changes to Technical Specification Administrative Controls Section ML0810700492008-04-15015 April 2008 Technical Specification 5.5.7, Inservice Testing Program Tac No. MD5713) ML0810700612008-04-0404 April 2008 National Pollutant Discharge Elimination System (NPDES) Application for Permit Renewal ML0805200082008-02-20020 February 2008 Revised Technical Specifications, Regarding Control Room Envelope Habitability in Accordance with Technical Specification Task Force-448, (TSTF-448), Revision 3, Using the Consolidated Line Item Improvement Process ML0803202842008-01-31031 January 2008 License Amendment Request to Support Use of M5 Alloy ML0728500762007-10-0404 October 2007 Tech Spec Page for Amendment 228 Proposal to Revise Containment Sump Surveillance Requirement to Verify Strainer Integrity ML0727600042007-10-0202 October 2007 Technical Specifications, Issuance of Amendment Replacement of Containment Sump Buffer ML0727400132007-09-28028 September 2007 Technical Specifications, Implemented Alternative Radiological Source Term ML0723304672007-08-21021 August 2007 Application to Revise Technical Specifications Regarding Control Room Envelope Habitability in Accordance with TSTF-448, Revision 3, Using the Consolidated Line Item Improvement Process ML0723203922007-08-20020 August 2007 Response to Request for Additional Information - License Amendment Request for Replacement of Containment Sump Buffer ML0711303562007-04-18018 April 2007 Palisades, License Amendment Request: Emergency Core Cooling System Surveillance Requirement ML0709901082007-04-0606 April 2007 Tech Spec Page 4.0-1 Re Design Features ML0707406532007-03-15015 March 2007 License Amendment Request: Changes to Technical Specification Use and Application and Administrative Controls Sections ML0706400582007-02-27027 February 2007 Response to Request for Additional Information Regarding Proposed C* License Amendment Request for Steam Generator Tube Repair in the Tubesheet ML0701100532007-01-10010 January 2007 Facility Operating License DPR-20, Appendix a (Technical Specifications) ML0618801652006-07-0606 July 2006 Technical Specification Pages Re Steam Generator ML0609604662006-03-29029 March 2006 2005 Annual Radioactive Effluent Release and Waste Disposal Report, Palisades ML0608705662006-03-27027 March 2006 Tech Spec Page for Amendment 222 Revised Fuel Assembly Growth Model L-HU-06-001, Application for Technical Specification Improvement Regarding Steam Generator Tube Integrity2006-02-16016 February 2006 Application for Technical Specification Improvement Regarding Steam Generator Tube Integrity ML0505600162005-02-22022 February 2005 Corrected Technical Specification Pages, Amendment No. 221 ML0501403722005-01-11011 January 2005 Technical Specifications, Elimination of Requirements for Hydrogen Recombiners and Hydrogen Monitors (MC1903) ML0501403852005-01-10010 January 2005 Tech Spec Pages for Amendment 220 Deletion of Requirements for Submittal of Occupational Radiation and Monthly Operating Reports 2023-12-27
[Table view] |
Text
Entergy Nuclear Operations, Inc.
Palisades Nuclear Plant EnterV 27780 Blue Star Memorial Highway Covert, MI 49043 Tel 269 764 2000 August 28, 2008 10 CFR 50.90 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Palisades Nuclear Plant Docket 50-255 License No. DPR-20 License Amendment Request: Changes to Technical Specification Administrative Controls Section
Dear Sir or Madam:
Pursuant to 10 CFR 50. 90, Entergy Nuclear Operations , Inc (ENO ) requests Nuclear Regulatory Commission ( NRC) review and approval of a proposed license amendment for the Palisades Nuclear Plant ( PNP). The proposed amendment changes Technical Specifications (TS) Administrative Controls section 5 to incorporate NRC-approved Technical Specification Task Force (TSTF) Improved Technical Specification (ITS)
TSTF-363, "Revise Topical Report references in ITS 5. 6.5, [Core Operating Limits Report] COLR ," revision 0 . ENO also proposes to make an administrative change to the plant staff qualifications section. provides a detailed description of the proposed changes, background and technical analysis, No Significant Hazards Consideration Determination, and Environmental Review Consideration. Enclosure 2 provides the revised TS pages reflecting the proposed changes. Enclosure 3 provides the annotated TS pages showing the proposed changes.
ENO requests approval of this proposed license amendment by September 1, 2009, with the amendment to be implemented within 60 days.
A copy of this request has been provided to the designated representative of the State of Michigan.
Document Control Desk Page 2 Summary of Commitments This letter contains no new commitments and no revision to existing commitments.
I declare under penalty of perjury that the foregoing is true and correct. Executed on August 28, 2008.
Enclosures (3)
CC Administrator , Region III, USNRC Project Manager , Palisades, USNRC Resident Inspector , Palisades , USNRC
ENCLOSURE 1 D ESC R IPTIO N R E Q UE STE D C H ANG ES to D E S C R IPTI ON Entergy Nuclear Operations , Inc (ENO ) requests to amend renewed facility operating license DPR-20 for the Palisades Nuclear Plant (PNP ). The proposed amendment affects the Technical Specifications (TS) Administrative Controls section . The proposed amendment changes TS Administrative Controls section 5 to incorporate Nuclear Regulatory Commission ( NRC)-approved Technical Specification Task Force (TSTF) Improved Technical Specification (ITS) change TSTF-363, "Revise Topical Report references in ITS 5.6.5, [Core Operating Limits Report] COLR," revision 0. ENO also proposes to make an administrative change to the plant staff qualifications section.
- 2. PROPOSED CHAN GES ENO proposes to revise TS as follows:
In TS 5.3.1, change "ANSI N18.1-1971" to "ANSI/ANS 3.1, 1978."
Change TS 5.6.5.b to read:
"b. The analytical methods used to determine the core operating limits shall be those previously reviewed and approved by the NRC, specifically those described in the following documents:"
In TS 5.6.5.b items 6, 17, and 18: delete "Revision 0,"
Markups showing the specific changes and the clean TS pages with those changes incorporated are provided in Enclosure 2 and 3, respectively.
- 3. 0 BACKGROUND Amendment 169 to facility operating license DPR-20, dated July 26 , 1995, added the COLR section to the PNP TS . This amendment predated TSTF-363 and PNP conversion to Standard Technical Specifications (STS). Therefore, the request did not fully model the NRC approved version of TSTF-363 or the current revision of the STS.
Amendment 189 to facility operating license DPR-20, dated November 30, 1999, converted PNP TS to STS. This amendment did not fully model the NRC approved version of TSTF-363 or the existing version of the STS.
Amendment 224 to renewed facility operating license DPR -20, dated April 11, 2007, was the conforming amendment for the sale of PNP to ENO.
ENO submitted Quality Assurance Program Manual (QAPM), revision 16, on June 15 , 2007 ( Reference 1). Entergy QAPM revision 16 extended the Entergy Page 1 of 5
Quality Assurance Program to PNP. PNP minimum staff qualification requirements in TS section 5.3.1 are affected by the Entergy QAPM.
4.0 T EC HN ICAL ANALYSIS The proposed change to TS 5.3.1 updates the ANSI reference for minimum staff qualifications. The proposed plant staff minimum qualification ANSI standard would be changed to match the standard described in the Entergy QAPM. ENO considers this proposed change to be administrative in nature.
The proposed change to TS 5.6.5.b revises the wording to be consistent with NRC approved TSTF-363, revision 0 and NUREG-1432, "Standard Technical Specifications, Combustion Engineering Plants." Revision 16 to the PNP COLR (Reference 2) added the identification information expected by TSTF-363 for each topical report cited in TS 5.6.5.b. ENO considers this proposed change to be administrative in nature.
- 5. 0 REGULATORY SAFETY ANALYSIS 5.1 No Significant Hazards Consideration Pursuant to 10 CFR 50. 90, Entergy Nuclear Operations , Inc (ENO ) requests to amend renewed facility operating license D PR-20 for the Palisades Nuclear Plant. The proposed amendment changes TS Administrative Controls section 5 to incorporate Nuclear Regulatory Commission ( NRC)-approved Technical Specification Task Force (TSTF) Improved Technical Specification ( ITS) change TSTF-363, "Revise Topical Report references in ITS 5 .6.5, [Core Operating Limits Report] COLR ," revision 0. ENO also proposes to make an administrative change to the plant staff qualifications section.
ENO has evaluated whether or not a significant hazards consideration is involved with the proposed amendment by focusing on the three standards set forth in 10 CFR 50. 92, "Issuance of Amendment ," as discussed below:
- 1. Does the proposed amendment involve a significant increase in the probability or consequences of an accident previously evaluated?
Response: No.
The proposed amendment does not involve a significant increase in the probability or consequences of an accident previously evaluated. The proposed changes are administrative or provide clarification only.
The proposed changes do not have any impact on the integrity of any plant system, structure, or component that initiates an analyzed event.
The proposed changes will not alter the operation of, or otherwise Page 2 of 5
increase the failure probability of any plant equipment that initiates an analyzed accident. Thus, the probability of any accident previously evaluated is not significantly increased.
The proposed changes do not affect the ability to mitigate previously evaluated accidents, and do not affect radiological assumptions used in the evaluations. The proposed changes do not change or alter the design criteria for the systems or components used to mitigate the consequences of any design basis accident. The proposed amendment does not involve operation of the required structures, systems, or components (SSCs) in a manner or configuration different from those previously recognized or evaluated. Thus, the radiological consequences of any accident previously evaluated are not increased.
Therefore, operation of the facility in accordance with the proposed amendment does not involve a significant increase in the probability or consequences of an accident previously evaluated.
- 2. Does the proposed amendment create the possibility of a new or different kind of accident from any accident previously evaluated?
Response: No.
The proposed amendment does not create the possibility of a new or different kind of accident from any accident previously evaluated. The proposed amendment does not involve a physical alteration of any SSC or a change in the way any SSC is operated. The proposed amendment does not involve operation of any required SSCs in a manner or configuration different from those previously recognized or evaluated. No new failure mechanisms will be introduced by the changes being requested.
Therefore, the proposed amendment does not create the possibility of a new or different kind of accident from any accident previously evaluated.
- 3. Does the proposed amendment involve a significant reduction in a margin of safety?
Response: No.
The amendment does not involve a significant reduction in a margin of safety. The proposed amendment does not affect any margin of safety.
The proposed amendment does not involve any physical changes to the plant or manner in which the plant is operated.
Therefore, the proposed amendment would not involve a significant reduction in a margin of safety.
Page 3 of 5
Based on the evaluation above, ENO concludes that the proposed amendment presents no significant hazards consideration under the standards set forth in 10 CFR 50.92(c).
5.2 Applicable Regulatory Requirements/Criteria The function of the "Administrative Controls" section of the TS, as stated in 10 CFR 50.36(d)(5), is to provide "provisions relating to organization and management, procedures, recordkeeping, review and audit, and reporting necessary to assure operation of the facility in a safe manner." The proposed changes continue to meet these objectives.
The proposed changes are consistent with NUREG-1432 and TSTF-363.
In conclusion, based on the considerations discussed above, (1) there is reasonable assurance that the health and safety of the public will not be endangered by operation in the proposed manner, (2) such activities will be conducted in compliance with the Commission's regulations, and (3) the issuance of the amendment will not be inimical to the common defense and security or to the health and safety of the public.
- 6. EN VI RONM ENTAL CON SI DERATI ON ENO has determined that the proposed amendment is confined to (i) changes to surety, insurance, and/or indemnity requirements, or (ii) changes to recordkeeping, reporting, or administrative procedures or requirements.
Accordingly, the proposed amendment meets the eligibility criterion for categorical exclusion set forth in 10 CFR 51.22(c)(10). Therefore, pursuant to 10 CFR 51.22(b), no environmental impact statement or environmental assessment need be prepared in connection with the proposed amendment.
- 7. 0 REFERENCES Letter from ENO to NRC, "Annual Report for Quality Assurance Program Manual Changes under 10 CFR 50.54(a)(3) and 10 CFR 72.140(d)
Notification of Application of Approved Appendix B to 10 CFR 72 subpart G," dated June 15, 2007 (ADAMS Accession number M I-071770254)
- 2. Letter from ENO to NRC, "Core Operating Limits Report - Revision 16,"
dated May 1, 2008 (ADAMS Accession number ML081500826)
Page 4 of 5
8.0 PRECEDEN T By letter dated December 20, 2001, Duke Energy Corporation submitted a LAR for Oconee Nuclear Station, Units 1, 2, and 3 (ADAMS Accession number ML020520153). The LAR requested changes to the Oconee TS, specifically, changes that implement TSTF-363. By letter dated July 9, 2002, the NRC approved the LAR for Oconee (ADAMS Accession number ML021900580).
Similar to this submittal, ENO is requesting approval to implement TSTF-363.
ENO proposes to implement TSTF-363 with no deviations.
Page 5 of 5
ENCLOSURE 2 LICE N S E AMENDM E N T REQ U E ST: CHAN GES TO TE CHN ICAL S PE CIFI CATI ON ADMINISTRATIVE CONT R OLS SECTI ON REVISED TECHNICAL SPECIFICATION PAGES 5.0-4, 5.0-25, 5.0-26, and 5.0-27 AND OPERATING LICENSE PAGE CHANGE INSTRUCTIONS 5 Pages Follow
ATTACHM E N T TO LI CENS E AM E NDM E N T NO.
R E N E W E D FAC ILI TY OPERATING LICENSE NO. DPR-20 DOCKET NO . 50-2 Remove the following pages of Appendix A Technical Specifications and replace with the attached revised pages. The revised pages are identified by amendment number and contain marginal lines indicating the areas of change.
REMOVE INSERT 5.0-4 5.0-4 5.0-25 5.0-25 5.0-26 5.0-26 5.0-27 5.0-27
Plant Staff Qualifications 5.3 5.0 ADMINISTRATIVE CONTROLS 5.3 Plant Staff Qualifications 5.3.1 Each member of the plant staff shall meet or exceed the minimum qualifications of ANSI/ANS 3.1, 1978 for comparable positions except for the education and experience eligibility requirements for operator license applicants, and changes thereto, shall be those previously reviewed and approved by the NRC, specifically those referenced in NRC Safety Evaluation dated October 24, 2003.
5.3.2 The radiation safety manager shall meet the qualifications of a Radiation Protection Manager as defined in Regulatory Guide 1.8, September 1975. For the purpose of this section, "Equivalent," as utilized in Regulatory Guide 1.8 for the bachelor's degree requirement, may be met with four years of any one or combination of the following: (a) Formal schooling in science or engineering, or (b) operational or technical experience and training in nuclear power.
5.3.3 The individual, required by Specification 5.2.2g, assigned to provide advisory technical support to the plant operations shift crew, shall meet the qualifications specified by the Commission Policy Statement on Engineering Expertise on Shift (Published in Federal Register 50 FR 43621, October 28, 1985).
5.3.4 (Deleted) 5.3.5 For the purpose of 10 CFR 55.4, a licensed Senior Reactor Operator (SRO) and a licensed reactor operator (RO) are those individuals who, in addition to meeting the requirements of TS 5.3.1, perform the functions described in 10 CFR 50.54(m).
Palisades Nuclear Plant 5.0-4 Amendment No. 4,, 24-2, 234,
rceporting Requirements 5.6 5.6 Reporting Requirements 5.6.4 (Deleted) 5.6.5 CORE OPERATING LIMITS REPORT (COLR)
- a. Core operating limits shall be established prior to each reload cycle, or prior to any remaining portion of a reload cycle, and shall be documented in the COLR for the following:
3.1.1 Shutdown Margin 3.1.6 Regulating Rod Group Position Limits 3.2.1 Linear Heat Rate Limits 3.2.2 Radial Peaking Factor Limits 3.2.4 ASI Limits 3.4.1 DNB Limits
- b. The analytical methods used to determine the core operating limits shall be those previously reviewed and approved by the NRC, specifically those described in the following documents:
EMF-96-029 (P)(A) Volumes 1 and 2, "Reactor Analysis System for PWRs," Siemens Power Corporation.
(LCOs 3.1.1, 3.1.6, 3.2.1, 3.2.2, & 3.2.4)
- 2. ANF-84-73 Appendix B (P)(A), "Advanced Nuclear Fuels Methodology for Pressurized Water Reactors: Analysis of Chapter 15 Events," Advanced Nuclear Fuels Corporation. (Bases report not approved) (LCOs 3.1.1, 3.1.6, 3.2.1, 3.2.2, & 3.2.4)
- 3. XN-NF-82-21 (P)(A), "Application of Exxon Nuclear Company PWR Thermal Margin Methodology to Mixed Core Configurations," Exxon Nuclear Company.
(LCOs 3.2.1, 3.2.2, & 3.2.4)
- 4. EMF-84-093(P)(A), "Steam Line Break Methodology for PWRs, "Siemens Power Corporation.
(LCOs 3.1.1, 3.1.6, 3.2.1, 3.2.2, & 3.2.4)
- 5. XN-75-32(P)(A) Supplements 1 through 4, "Computational Procedure for Evaluating Fuel Rod Bowing," Exxon Nuclear Company. (Bases document not approved)
(LCOs 3.1.6, 3.2.1, 3.2.2, & 3.2.4)
Palisades Nuclear Plant 5.0-25 Amendment No. 48 , 2, 220,
Reporting Requirements 5.6 5.6 Reporting Requirements 5.6.5 COLR ( continued)
- 6. EMF-2310 (P)(A), Framatome ANP, Inc., May 2001, "SRP Chapter 15 Non-LOCA Methodology for Pressurized Water Reactors." (LCOs 3.1.6, 3.2.1, 3.2.2, & 3.2.4)
- 7. XN-NF-78-44(NP)(A), "A Generic Analysis of the Control Rod Ejection Transient for Pressurized Water Reactors," Exxon Nuclear Company. (LCOs 3.1.6, 3.2.1, & 3.2.2)
ANF-89-151 (P)(A), "ANF-RELAP Methodology for Pressurized Water Reactors: Analysis of Non-LOCA Chapter 15 Events,"
Advanced Nuclear Fuels Corporation.
(LCOs 3.1.6, 3.2.1, 3.2.2, & 3.2.4)
EMF-92-153(P)(A) and Supplement 1, "HTP: Departure from Nucleate Boiling Correlation for High Thermal Performance Fuel,"
Siemens Power Corporation. (LCOs 3.2.1, 3.2.2, & 3.2.4)
- 10. XN-NF-621(P)(A), "Exxon Nuclear DNB Correlation for PWR Fuel Designs," Exxon Nuclear Company. (LCOs 3.2.1, 3.2.2, & 3.2.4)
- 11. XN-NF-82-06(P)(A) and Supplements 2, 4, and 5, "Qualification of Exxon Nuclear Fuel for Extended Burnup," Exxon Nuclear Company. (LCOs 3.1.6, 3.2.1, 3.2.2, & 3.2.4)
- 12. ANF-88-133(P)(A) and Supplement 1, "Qualification of Advanced Nuclear Fuels' PWR Design Methodology for Rod Burnups of 62 GWD/MTU," Advanced Nuclear Fuels Corporation.
(LCOs 3.1.6, 3.2.1, 3.2.2, & 3.2.4)
- 13. XN-NF-85-92(P)(A), "Exxon Nuclear Uranium Dioxide/Gadolinia Irradiation Examination and Thermal Conductivity Results," Exxon Nuclear Company. (LCOs 3.1.6, 3.2.1, 3.2.2, & 3.2.4)
Palisades Nuclear Plant 5.0-26 Amendment No. 499, 20-9,
Reporting Requirements 5.6 5.6 Reporting Requirements 5.6.5 COLR ( continued)
- 14. EMF-92-116(P)(A), "Generic Mechanical Design Criteria for PWR Fuel Designs ," Siemens Power Corporation.
(LCOs 3.1.6, 3.2.1, 3.2.2, & 3.2.4)
- 15. EMF-2087(P)(A), "SEM/PWR-98: ECCS Evaluation Model for PWR LBLOCA Applications," Siemens Power Corporation.
(LCOs 3.1.6, 3.2.1, & 3.2.2)
- 16. ANF-87-150 Volume 2, "Palisades Modified Reactor Protection System Report: Analysis of Chapter 15 Events," Advanced Nuclear Fuels Corporation. [Approved for use in the Palisades design during the NRC review of license Amendment 118, November 15, 1988] (LCOs 3.1.6, 3.2.1, 3.2.2, & 3.4.1)
- 17. EMF-1961(P)(A), Siemens Power Corporation, July 2000, "Statistical Setpoint/Transient Methodology for Combustion Engineering Type Reactors." (LCOs 3.1.6, 3.2.1, 3.2.2, 3.2.4, &
3.4.1)
- 18. EMF-2328 (P)(A), Framatome ANP, Inc., March 2001, "PWR Small Break LOCA Evaluation Model, S-RELAP5 Based." (LCOs 3.1.6, 3.2.1, & 3.2.2)
- 19. BAW-2489P, "Revised Fuel Assembly Growth Correlation for Palisades." (LCOs 3.1.6, 3.2.1, 3.2.2, & 3.2.4)
- 20. EMF-2103(P)(A), "Realistic Large Break LOCA Methodology for Pressurized Water Reactors." (LCOs 3.1.6, 3.2.1, & 3.2.2)
The core operating limits shall be determined such that all applicable limits (e.g., fuel thermal mechanical limits, core thermal hydraulic limits, Emergency Core Cooling Systems limits, nuclear limits such as shutdown margin, transient analysis limits, and accident analysis limits) of the safety analysis are met.
The COLR, including any mid cycle revisions or supplements , shall be provided, upon issuance for each reload cycle, to the NRC.
Palisades Nuclear Plant 5.0-27 Amendment No. 4-9, 4-95, 2-89, 247-, 222-,
ENCLOSURE LI CEN SE AMENDM E NT R E Q UEST : CHAN G ES TO TECHNICAL SPECIFICATI ON ADMINISTRATIVE CON T RO LS SECTI ON MARK-UP OF TECHNICAL SPECIFICATION PAGES 5.0-4, 5.0-25, 5.0-26, and 5.0-27 (showing proposed changes)
(additions are highlighted; deletions are strikethrough) 4 Pages Follow
Plant Staff Qualifications 5.3 5.0 ADMINISTRATIVE CONTROLS 5.3 Plant Staff Qualifications 5.3.1 Each member of the plant staff shall meet or exceed the minimum qualifications of for comparable positions except for the education and experience eligibility requirements for operator license applicants, and changes thereto , shall be those previously reviewed and approved by the NRC, specifically those referenced in NRC Safety Evaluation dated October 24, 2003.
5.3.2 The radiation safety manager shall meet the qualifications of a Radiation Protection Manager as defined in Regulatory Guide 1.8, September 1975. For the purpose of this section, "Equivalent," as utilized in Regulatory Guide 1.8 for the bachelor's degree requirement, may be met with four years of any one or ,.,
combination of the following: (a) Formal schooling in science or engineering, or (b) operational or technical experience and training in nuclear power.
5.3.3 The individual, required by Specification 5.2.2g, assigned to provide advisory technical support to the plant operations shift crew, shall meet the qualifications specified by the Commission Policy Statement on Engineering Expertise on Shift (Published in Federal Register 50 FR 43621, October 28, 1985).
5.3.4 (Deleted) 5.3.5 For the purpose of 10 CFR 55.4, a licensed Senior Reactor Operator (SRO) and a licensed reactor operator (RO) are those individuals who, in addition to meeting the requirements of TS 5.3.1, perform the functions described in 10 CFR 50.54(m).
Palisades Nuclear Plant 5.0-4 Amendment No. , 496, 24-2, 231
Reporting Requirements 5.6 5.6 Reporting Requirements 5.6.4 (Deleted) 5.6.5 CORE OPERATING LIMITS REPORT (COLR)
- a. Core operating limits shall be established prior to each reload cycle, or prior to any remaining portion of a reload cycle, and shall be documented in the COLR for the following:
3.1.1 Shutdown Margin 3.1.6 Regulating Rod Group Position Limits 3.2.1 Linear Heat Rate Limits 3.2.2 Radial Peaking Factor Limits 3.2.4 ASI Limits 3.4.1 DNB Limits The analytical methods used to determine the core operating limits shall be those approved by the NRC, specifically those described in the latest approved r n of the following documents:
EMF-96-029(P)(A) Volumes 1 and 2, "Reactor Analysis System for PWRs," Siemens Power Corporation.
(LCOs 3.1.1, 3.1.6, 3.2.1, 3.2.2, & 3.2.4)
- 2. ANF-84-73 Appendix B (P)(A), "Advanced Nuclear Fuels Methodology for Pressurized Water Reactors : Analysis of Chapter 15 Events," Advanced Nuclear Fuels Corporation . ( Bases report not approved ) (LCOs 3.1.1, 3.1.6, 3.2.1, 3.2.2, & 3.2.4)
- 3. XN-NF-82-21(P)(A), "Application of Exxon Nuclear Company PWR Thermal Margin Methodology to Mixed Core Configurations," Exxon Nuclear Company.
(LCOs 3.2.1, 3.2.2, & 3.2.4) 4 EMF-84-093(P)(A), "Steam Line Break Methodology for PWRs, "Siemens Power Corporation.
(LCOs 3.1.1, 3.1.6, 3.2.1, 3.2.2, & 3.2.4)
XN-75-32(P)(A) Supplements 1 through 4, "Computational Procedure for Evaluating Fuel Rod Bowing," Exxon Nuclear Company. (Bases document not approved)
(LCOs 3.1.6, 3.2.1, 3.2.2, & 3.2.4)
Palisades Nuclear Plant 5.0-25 Amendment No. 1 9, 21-7, 220
Reporting Requirements 5.6 5.6 Reporting Requirements 5.6.5 COLR ( continued)
- 6. EMF-231 0 (P)(A), Re,^, Framatome ANP, Inc., May 2001, "SRP Chapter 15 Non-LOCA Methodology for Pressurized Water Reactors." (LCOs 3.1.6, 3.2.1, 3.2.2, & 3.2.4)
- 7. XN-NF-78-44(NP)(A), "A Generic Analysis of the Control Rod Ejection Transient for Pressurized Water Reactors," Exxon Nuclear Company. (LCOs 3.1.6, 3.2.1, & 3.2.2)
- 8. ANF-89-151 (P)(A), "ANF-RELAP Methodology for Pressurized Water Reactors: Analysis of Non-LOCA Chapter 15 Events,"
Advanced Nuclear Fuels Corporation.
(LCOs 3.1.6, 3.2.1, 3.2.2, & 3.2.4)
EMF-92-153(P)(A) and Supplement 1, "HTP: Departure from Nucleate Boiling Correlation for High Thermal Performance Fuel,"
Siemens Power Corporation. (LCOs 3.2.1, 3.2.2, & 3.2.4)
- 10. XN-NF-621(P)(A), "Exxon Nuclear DNB Correlation for PWR Fuel Designs," Exxon Nuclear Company. (LCOs 3.2.1, 3.2.2, & 3.2.4)
- 11. XN-NF-82-06(P)(A) and Supplements 2, 4, and 5, "Qualification of Exxon Nuclear Fuel for Extended Burnup," Exxon Nuclear Company. (LCOs 3.1.6, 3.2.1, 3.2.2, & 3.2.4)
- 12. ANF-88-133(P)(A) and Supplement 1, "Qualification of Advanced Nuclear Fuels' PWR Design Methodology for Rod Burnups of 62 GWD/MTU," Advanced Nuclear Fuels Corporation.
(LCOs 3.1.6, 3.2.1, 3.2.2, & 3.2.4)
- 13. XN-NF-85-92(P)(A), "Exxon Nuclear Uranium Dioxide/Gadolinia Irradiation Examination and Thermal Conductivity Results," Exxon Nuclear Company. (LCOs 3.1.6, 3.2.1, 3.2.2, & 3.2.4)
Palisades Nuclear Plant 5.0-26 Amendment No. 4&9, 209
Reporting Requirements 5.6 5.6 Reporting Requirements 5.6.5 COLR (continued)
- 14. EMF-92-116(P)(A), "Generic Mechanical Design Criteria for PWR Fuel Designs," Siemens Power Corporation.
(LCOs 3.1.6, 3.2.1, 3.2.2, & 3.2.4)
- 15. EMF-2087(P)(A), "SEM/PWR-98: ECCS Evaluation Model for PWR LBLOCA Applications," Siemens Power Corporation.
(LCOs 3.1.6, 3.2.1, & 3.2.2)
- 16. ANF-87-150 Volume 2, "Palisades Modified Reactor Protection System Report: Analysis of Chapter 15 Events," Advanced Nuclear Fuels Corporation. [Approved for use in the Palisades design during the NRC review of license Amendment 118, November 15, 1988] (LCOs 3.1.6, 3.2.1, 3.2.2, & 3.4.1)
- 17. EMF-1961(P)(A), Revis on 0, Siemens Power Corporation, July 2000, "Statistical Setpoint/Transient Methodology for Combustion Engineering Type Reactors." (LCOs 3.1.6, 3.2.1, 3.2.2, 3.2.4, &
3.4.1)
- 18. EMF-2328 (P)(A), Rev ision 0, Framatome ANP, Inc., March 2001, "PWR Small Break LOCA Evaluation Model , S-RELAP5 Based."
(LCOs 3.1.6, 3.2.1, & 3.2.2)
- 19. BAW-2489P, "Revised Fuel Assembly Growth Correlation for Palisades." (LCOs 3.1.6, 3.2.1, 3.2.2, & 3.2.4)
- 20. EMF-2103(P)(A), "Realistic Large Break LOCA Methodology for Pressurized Water Reactors." (LCOs 3.1.6, 3.2.1, & 3.2.2)
- c. The core operating limits shall be determined such that all applicable limits (e.g., fuel thermal mechanical limits, core thermal hydraulic limits, Emergency Core Cooling Systems limits, nuclear limits such as shutdown margin, transient analysis limits, and accident analysis limits) of the safety analysis are met.
- d. The COLR, including any mid cycle revisions or supplements, shall be provided, upon issuance for each reload cycle, to the NRC.
Palisades Nuclear Plant 5.0-27 Amendment No. 449, .4-9-5, 2.09, ,
229