fikEntergy August 20, 2007 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Palisades Nuclear Plant Docket 50-255 License No. DPR-20 Entergy Nuclear O perations, Inc.
Palisades Nuclear Plant 27780 Blue Star Memorial Highway Covert, MI 49043 10 CFR 50.90 Response to Request for Additional Information - License Amendment Request for Replacement of Containment Sump Buffer (TAC No. MD5893)
Dear Sir or Madam:
Entergy Nuclear Operations, Inc., (ENO) submitted a license amendment request (LAR) on June 29, 2007, to change the containment sump buffering agent from trisodium phosphate (TSP) to sodium tetraborate decahydrate (STB) for Palisades Nuclear Plant (PNP). On July 31, 2007, the Nuclear Regulatory Commission (NRC) electronically sent a request for additional information (RAI) on the LAR. On August 7, 2007, a teleconference was held with the NRC to discuss the RAI issues. provides the response to the RAI. provides revised Technical Specifications (TS) pages. provides the annotated TS pages showing the proposed changes.
By letter dated September 25, 2006, Nuclear Management Company, LLC, the former licensee for the PNP requested NRC review and approval of a LAR (TAC No. MD3087) to modify the PNP licensing basis to adopt the alternative source term methodology.
In a telephone call on July 17, 2007, ENO agreed that the implementation of the alternative source term LAR should be contingent on the approval of the LAR for replacement of the containment sump buffer. ENO will work with the NRC project manager, as necessary, to coordinate the changes.
Summary of Commitments This letter contains no new commitments and no revision to existing commitments.
I declare under penalty of perjury that the foregoing is true and correct.
Executed on August 20, 2007.
gri oppher J. Sch Site Vice President Palisades Nuclear Plant Enclosures (3)
CC Administrator, Region III, USNRC Project Manager, Palisades, USNRC Resident Inspector, Palisades, USNRC
ENCLOSURE 1 RAI RESPONSE - REPLACEMENT OF CONTAINMENT SU MP BUFFER LAIR PALISADES NUCLEAR PLANT Entergy Nuclear Operations, Inc., (ENO) submitted a license amendment request (LAR) on June 29, 2007, to change the containment sump buffering agent from trisodium phosphate (TSP) to sodium tetraborate decahydrate (STB).
On July 31, 2007, the Nuclear Regulatory Commission (NRC) electronically sent a request for additional information (RAI) on the LAR. On August 7, 2007, a teleconference was held with the NRC to discuss the issues in the RAI. The RAI issues and the ENO responses follow.
NRC Request Provide copies of the WCAP-16530-NP ["Evaluation of Post-Accident Chemical Effects in containment Sump Fluids to Support GSI-191 "]
spreadsheets for Palisades under both trisodium phosphate (TSP) and sodium tetraborate decahydrate (STB) conditions.
Include all assumptions for temperature, pH, and material inventory input to the model.
ENO Response Copies of the WCAP-1 6530-NP spreadsheets for TSP and STB conditions are included in Attachments 1 and 2 respectively. The spreadsheets include the values for temperature, pH, and material used in the model.
NRC Request 2.
Please describe the procedure for [Technical Specifications] Surveillance Requirement 3.5.5.2. [Verify that a sample from the STB baskets provides adequate pH adjustment of borated water every 18 months]
A. How is the sample obtained? How does the sampling account for the potential that STS on the interior of the basket may exhibit different properties (hydration, density, etc) than samples taken from the basket periphery? Discuss the potential impact that variations in material properties within each basket may have on the accuracy of the pH verification surveillance.
ENO Response 2.
A. Two surveillance procedures implement Technical Specification (TS) 3.5.5, "Containment Sump Buffering Agent and Weight Requirements."
The procedures are being revised to incorporate the change of the sump buffering agent from TSP to STB.
Procedure number RM-124, "Sodium Tetraborate Basket Weights," would be revised to verify the weight of the STB in the baskets.
Procedure number RC-123, "Sodium Tetraborate Page 1 of 6
ENCLOSURE 1 RAI RESPONSE - REPLACEMENT OF CONTAINMENT SUMP BUFFER LAR PALISAD ES N UCLEAR PLANT Decahydrate Buffering Tests," would be revised to verify that the STB in the baskets would provide the required pH control of the post loss-of-coolant accident (LOCA) sump water.
Both procedures are performed in an 18 -month interval.
Procedure RIVI-124, which corresponds to TS Surveillance Requirement 3.5.5.1, would provide steps for weighing each of the twenty STB baskets by the use of a calibrated portable scale. The initial empty weight of each basket would be subtracted from the actual weight of the basket plus STB. The total of the all twenty baskets would be added together to verify the weight is within the lower and upper limits in the proposed Technical Specification surveillance requirement of >_ 8,186 pounds and <_ 10,533 pounds of equivalent weight sodium tetraborate decahydrate. The total as-found weight of STB would be evaluated and trended and a determination would be made if STB needs to be added to the STB baskets. The procedure would require that a boron concentration of the STB be performed, when the total STB weight is below 8,211 pounds (8,186 pound minimum plus 25 pounds), to determine whether the loss of weight is due to dehydration of the decahydrate form of STB.
If the total weight is otherwise within the specified range, no boron concentration test is required.
The STB baskets design length, width, and height are two feet by two feet by three feet two inches. The baskets would be raised off the floor by four-inch legs, and they would be filled with STB to a height of approximately two feet. A 100 mesh inner screen would line the baskets within a four mesh outer screen to contain the STB.
Procedure RC-123, which corresponds to TS Surveillance Requirement 3.5.5.2, would provide steps for sampling from one of the STB baskets and performing a pH test. A different basket is sampled each refueling outage. The procedure would require using a clean tool to scrape away several inches from the top layer of STB and obtain 10-15 grams of STB from the bottom of the scrape area. A controlled amount of the STB sample would then be placed into a heated boric acid solution and cooled to 25°C. The pH of the solution would then be measured and compared to the procedure acceptance criterion of between 7.1 and 7.9.
The STB to be installed inside the containment was procured per Borax Inc. specifications for decahydrate grade special quality granular STB. A certificate of analysis was provided by Borax demonstrating the compliance of the deliverables to the product specification. The receipt Page 2 of 6
ENCLOSURE 1 1 RESPONSE REPLAC EMENT OF CONTAINMENT SUMP BUFFER LAR PALISADES NUCLEAR PLANT inspection included an additional bulk chemical check to ensure the product specification is met by measuring the boron and sodium contents.
ENO expects that the dehydration of the decahydrate form of the STB would occur in service.
It is likely that the dehydration process is faster for the outer peripheral material in the STB basket.
Nonetheless, the chemical composition of the STB is not changed by the dehydration. As described in the response to issue 3. below, the aforementioned surveillance procedures account for the weight changes to ensure the design function of post-LOCA sump pH control is maintained.
C Request 2.
B.
Tests conducted under WCAP 16596-NP indicate that STB is readily dissolved. Is there a potential for the varying levels of hydration (based on changes in atmospheric conditions) to affect the dissolution rate of the sodium tetraborate over time? Are dissolution tests performed during each surveillance?
ENO Response 2.
B.
Refer to the response to 2.C. below.
NRC Request 2.
C.
Discuss the potential for sodium tetraborate pellets to fuse into larger blocks over time as a result of fluctuating humidity levels.
If this were to occur, what would the impact on dissolution time be? How does the current surveillance requirement account for this potential phenomena?
ENO Response 2.
C.
Dehydration of the decahydrate form of STB is expected to occur in the containment environment.
It is likely that there would be varying levels of dehydration of the STB in the STB baskets due to the varying degree of exposure to the containment environment. The dehydration does not have adverse effects on the dissolution time.
The STB is expected to form clumps due to local dissolution and re-precipitation under the in-service conditions of containment environment.
This phenomenon is referred by the STB manufacturer as "caking" and does not chemically change the sodium tetraborate portion of the material.
Asa part of WCAP-16596-P environmental effects testing, the Page 3 of 6
ENCLOSURE 1 RAI RESPONSE - REPLACEMENT OF CONTAI NMENT SUMP BUFFER LAR PALISADES NUCLEAR PLANT STB test specimen was exposed to simulated storage condition for 30 days at 150°F and 30% humidity. The STB specimen formed a solid clump. The test results showed that relative to that of the granular form, the clumped STB took longer to dissolve. The increase of dissolution time is considered as the result of surface area reduction.
Nevertheless, WCAP-1 6596-P did not identify any concern about the increase of the dissolution time. The WCAP-1 6596-P concluded that the clumped STB product is readily dissolved.
The licensee has performed a parametric analysis of the surface dissolution rates (SDR) of both TSP and STB.
First, the buffer agent samples were prepared by compacting in a one inch diameter by one inch tall cylinder. The molded samples were placed in boric acid solution for testing of the dissolution time. An analytical model was developed to convert the measured dissolution time of the molded sample into SDR.
The SDR pertains to the dissolution rate of a solid block of the buffer agent.
It is independent of the shape and size of the block. Tabulated below are the results from the parametric study.
It showed that the dissolution rate for STB is substantially higher than the rate of TSP which is the present sump buffer agent.
Since the density and amount of the STB employed are comparable to those of the TSP, the calculated SDR predicts that the dissolution time for STB is significantly shorter than that of the TSP.
Temp OF STB SDR Ibm/ft2-min TSP SDR Ibm/ft2-min 130 28.4 0.553 160 33.3 3.39 190 41.2 6.39 Based on the generic dissolution time tests described in the WCAP-6596-P and the aforementioned SDR analysis results, ENO does not consider the dissolution time of STB as a limiting design parameter.
Procedures RM-1 24 and RC-1 23 provide sufficient assurance for meeting the design requirements of timely control of the post-LOCA sump pH. No surveillance requirement is planned for the dissolution time of the STB in the STB baskets.
NRC Request 3.
Loss of waters of hydration from STB reduces its bulk weight, even though the amount of active chemical remains unchanged.
If additional STB is added over time to make up for the water weight loss, can an excess of STB Page 4 of 6
ENC LOSU RE 1 RAI R ESPONSE - REPLAC EM ENT OF CONTA I NM ENT SUMP BUFFER LAR PALISADES NUCLEAR PLANT accumulate such that the pH could exceed the maximum calculated level?
The result of higher pH would be increased aluminum dissolution, and consequently, increased aluminum based precipitates.
The submittal states that an assay of the boron content will be used to determine the equivalent weight of sodium tetraborate decahydrate.
Please describe the boron assay procedure, frequency, and safeguards in place to ensure that the maximum amount of STB in the baskets is not exceeded.
ENO Response 3.
ENO is incorporating administrative controls on the amount of STB in the containment to assure the TS requirements are met.
Regarding the STB weight loss due to dehydration, WCAP-1 6596-NP reported that a STB sample lost 23% of its weight when exposed to a 150°F and 30% humidity environment for 30 days. The 23% weight change corresponds to the loss of five parts of the ten water molecules attached to the decahydrate STB.
ENO is deploying the twenty STB baskets in the containment basement where the temperature is constantly well below 150°F with varying humidity levels over time. ENO does not have the operating data of the STB weight loss due to dehydration in the realistic containment environment, but expects the weight loss to be much less than 23%.
The addition of the STB would be controlled under the surveillance procedure RM-124. STB would be added to the containment only if it is determined that there is such a need. ENO is sensitive of the adverse effects of placing excessive amount of sump buffer agent inside containment.
Procedure R1VI-124 would control the amount of STB inventory to the lowest level practical.
There are several safeguards to minimize the amount of STB in the containment.
Initially, the STB baskets are to be loaded to a nominal 8,800 pounds of STB. This initial amount of the STB is sized to a nominal weight of 7.5% +/- 2% above the minimum Technical Specification requirement. This 7.5% weight margin addresses the expected weight loss due to dehydration, the allowed weight variation per decahydrate STB specification, instrument inaccuracy, potential loss during handling, and sampling usage.
Since the weight loss of the STB during service is expected, a special note would be included in the procedure RM-124 explicitly stating that STB need not be added as a result of dehydration.
If the total weight of the STB is below the minimum required amount, procedure RM-124 requires a boron concentration test be performed to determine whether the loss of weight is due to dehydration. ENO developed a boron concentration test procedure to verify boron concentration in the bulk chemical. The result is used to Page 5 of 6
ENCLOSURE 1 1 RESPONSE - REPLACEMENT OF CONTAINM ENT SUMP BUFFER LAR PALISADES N UCLEAR P LANT determine the needed adjustment of the STB basket weights to an equivalent weight of sodium tetraborate decahydrate. The boron concentration test would not have a specified frequency. To further raise the sensitivity of the adverse effects of placing excessive amount of STB inside the containment, the basis document for procedure R1VI-124 would address controlling the amount of STB to the lowest level practical.
NRC Request 4.
In the August 7, 2007, teleconference, the NRC identified that the TS table of contents page identifying the title change in TS section 3.5.5 had not been submitted on June 29, 2007.
ENO Response
- 4. provides page change instructions, the table of contents page ii that was not previously submitted, and the revised TS page 3.5.5-1 for section 3.5.5.
Page 3.5.5-1 is submitted for completeness.
provides the annotated TS pages showing the proposed changes. These enclosures replace the TS page changes and the annotated pages submitted in the June 29, 2007, letter.
Page 6 of 6
ATTACHMENT Results from WCAP-1 6530-NP, Rev. 0 "Evaluation of Post-Accident Chemical Effects in Containment Sump Fluids to Support GSI-191" DOCUMENT No. 2007-03464, REVISION 0 Pages 283 to 320 of 492 SPREADSHEET FOR PALISADES NUCLEAR PLANT TRISODIUM PHOSPHATE (TSP) BUFFER 39 Pages Follow
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 282 of 492 -G Results of WCAP-16530-NP, Rev. 0, (OG-06-255 and OG-06-378)
Spreadsheet for Palisades Nuclear Power Plant Unit 1, Break S2, Case 4, TSP Buffer and 100% ofthe Aluminum and Water in the Reactor Cavity, pH 8
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 283 of 492 Chemical Effects Calculation Use saturation pH for 20 minutes Palisades Unit 1 Start sump mixing after 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Stop spray after 30 days 5.1 SIRW Tank Water pH 11.54 Initial Sump pH 8.0 Equilibrium pH Cases A 7 Equilibrium pH Cases B 8 Equilibrium pH Time step Start Time (sec)
Time (min)
Time (hour)
Time (day)
Sump Temp.
(°F)
Sump Temp.
Step Cont.
Temp.
(°F)
Cont Temp.
Step Sump pH Spray pH Sump Mixed 1=yes 1
10 0.2 0.00 0.00 228.0 280.0 11,5 5.1 0
2 20 0.3 0.01 0.00 250.0 22.00 281.0 1.00 11.5 5.1 0
3 30 0.5 0.01 0.00 260.0 10.00 279.0
-2.00 11.5 5.1 0
4 60 1.0 0.02 0.00 268.0 8.00 276.0
-3.00 11.5 5.1 0
5 90 1.5 0.03 0.00
.':272.0 4.00 272.0
-4.00 11.5 5.1 0
6 300 5.0 0.08 0.00 277.0 5.00 265.0
-7.00 11.5 5.1
'.:0 7
600 10.0 0.17 0.01 275.0
-2.00 255.0
-10.00 11.5 5.1 0
8 900 15.0 0.25 0.01 271.0
-4.00 245.0
-10.00 11.5 5.1 0
9 1200 20.0 0.33 0.01 268.0
-3.00 240.0
-5.00 8.0 8.0 0
10 1500 25.0 0.42 0.02 261.0
-7.00 220.0
-20.00 8.0 8.0 0
11 1800 30.0 0.50 0.02 255.0
-6.00 215.0
-5.00 8.0 8.0 0
12 2700 45.0 0.75 0.03 243.0
-12.00 198.0
-17.00 8,0 8.0 0
13 3600 60.0 1.00 0.04 239.0
-4.00 216.0 18,00 8.0 8.0 0
14 5400 90.0 1.50 0.06 1
238.0 1
-1.00 is 221.0 5.00 8.0 8.0 0
15 7200 120,0 2.00 0.08 236.0
-2.00
-.I 222.0 1.00 8.0 8.0 0
16 14400 240.0 4.00 0.17 231.0
-5.00 220.0
-2.00 8.0 8.0 0
17 21600 360.0 6.00 0.25 225.0
-6.00 220.0 0.00 8.0 8.0 0
18 28800 480.0 8.00 0.33 216.0
-9.00 218.0
-2.00 8.0 8.0 0
19 36000 600.0 10.00 0.42 210.0
-6.00 212.0
-6.00 8.0 8.0 0
20 43200 720.0 12.00 0.50 206.0
-4.00 205.0
-7.00 8.0 8.0 21 50400 840.0 14.00 0.58 200.0
-6.00 201.0
-4,00 8.0 8.0 1
22 57600 960.0 16.00 0.67 196.0
-4.00 195.0
-6.00 8.0 8.0 23 72000 1200.0 20.00 0.83 190.0
-6.00 190.0 5.00 8.0 8.0 24 86400 1440.0 24.00 1.00 1 185.0 1
-5.00 185.0
-5.00 8.0 8.0 1'1 25 129600 2160.0 36.00 1.50 175.0
-10.00 175.0
-10,00 8.0 8.0 1
26 172800 2880.0 48.00 2.00 166.0
-9.00 165.0
-10.00 8.0 8.0 1
27 259200 4320.0 72.00 3.00 158.0
-8.00 155.0
-10.00 8.0 8.0 1
28 432000 7200.0 120.00 5.00 158.0 0.00 150.0
-5.00 8.0 8.0 1
29 626400 10440.0 174.00 7.25
- `
148.0
-10.00 137.0
-13.00 8.0 8.0 1
30 864000 14400.0 240.00 10.00 139.7
-8.30 126.0
-11,00 8.0 8.0 1
31 1296000 21600.0 360.00 15.00 134.0
-5.70 i16
. 7 1
-9.30 8.0 8.0 1
32 1728000 28800.0 480.00 20.00 130.3
-3.70 111.8
-4.95 8.0 8.0 1
33 2160000 36000.0 600.00 25.00 122.2
-8.10 102.2
-9.55 8.0 8.0 1
34 2592000 43200.0 720.00 30.00 120.0
-2.20 101.0
-1.20 8.0 8.0 1
Switchover to recirc at 20 minutes Start Mixing at 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />
'1g. s rig. 2 Fig. 13 Fig. 12 p Temp. Cont. Temp. Sump Temp.
Cont. Tem
(°F)
(°F)
(°F)
(°F) 228.00 277.00 228.00 280.1 250.00 278.00 249.00 281.1 259.00 278.00 260.00 279.(
264.00 276.00 268.00 276.(
269.00 272.0 272.00 272.(
271.00 262.00 277.00 265.(
270.00 252.00 275.00 255.1 268.00 234.00 271.00 245.(
260.00 221.00 268.00 240.(
254.00 213.00 261.00 220.(
249.00 200.00 255.00 215.(
231.50 174.00 243.00 198.(
229.00 185.00 239.00 216.(
227.00 190.0 238.00 221,(
220.00 189.0 236.00 222.(
215.00 180.00 231.00 220.(
198.00 178.00 225.00 220.(
192.00 178.00 216.00 218.1 182.00 172.00 210.00 212.0 174.00 166.00 206.00 205.1 170.00 162.00 200.00 201.(
166.00 158.00 196.00 195.C 162.00 155.0 190.00 190.C 157.00 152.0 185.00 185.C 151.00 147.00 175.00 175.(
148.00 140.00 166.00 165.
144.00 150.00 158.00 155.C 158.00 150.00 143.00 140.C 148.00 137.00 138.30 129,C 139.70 126.00 134.00 120.E 134.00 116.70 123.00 113.C 130.30 111.75 118.20 106.1 122.20 102.20 114.40 101.7 120.00 100.00 112.00 101.c
Entergy Palisades Nuclear Power Plant Project No. 12122-005 Chemical Effects Calculation Case 4
Buffer TSP pH 8.00 Palisades RC Al 100.0%
Unit 1
Start sump mixing after 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Stop spray after 30 days Materials Input Coolant Sump Pool Volume (gal) 394,307 gal Sump Pool Volume (ft3) 52,715 ft' Sump Pool Mass (lb) 3,289,406 lb Density 62.4 lb/ft3 8.34 lb/ga Aluminum
% Aluminum in Reactor Cavity Available 100%
Aluminum Submerged 31,951.7 ft 1,633.9 lb Aluminum Not Submerged 108,745.0 ft2 lb conversion factor 1.01E-05 kg/ft2 Latent ueorls
':. 200 Ib Latent Debris fiber 15.0%
30.0 lb Latent Debris particulate (cement) 85.0%
170.0 lb Concrete Particulate Concrete Concrete in Latent Debris 170.0 lb 77.1114941 kg Equivalent area of particulate concrete 7.67E+06 ft2 Exposed Concrete Submerged Solid Concrete (ft2) 679 ft2 Nonsubmerged Solid Concrete (ft2) 59,584 ft2 Total concrete area 7.73E+06 ft2 Trisodium Phosphate 11,000 Trisodium Phosphate Hydrate (Ibm) 11,000 Ib Attachment I Document No. 2007-03464 Revision 0 Page 284 of 492 P concentration Water in the Reactor Cavity 11000 lb Trisodium Phosphate 4822 ft' 3,289,406 lb Sump Pool Mass (Ib) 0.33%
TSP concentration lisades Cases This Case 4.00 1A 1B 2A 28 3A 3B 4A 4
iminum in RC 100.0%
100.0%
100.0%
50.0%
50.0%
0.0%
0.0%
100.0%
100.0%
questered Water in RC 0
0 0
2,411 2,411 4,822 4,822 0
0 ffer TSP STB STB STB STB STB STB TSP TSP P
11,000 0.00 0.00 0.00 0.00 0.00 0.00 11,000 11,000 uilibrium pH 8.00 7.00 8.00 7.00 8.00 7.00 8.00 7.00 8.00 ial sump pH 11.54 9.32 9.32 9.32 9.32 9.32 9.32 11.54 11.54
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 285 of 492 Insulation Break S2 Break S1 Break S2 Break S3 Break S4 Calcium Silicate CalSil (ft3) 153.3 ft3 127.60 153.26 114.03 92.73 Density 14.5 lb/ft3 Asbestos (ft3) 0.0 ft3 0.00 0.00 0.00 0.00 Density 10.0 lb/ft3 Kaylo (ft3) 0.0 ft3 0.00 0.00 0.00 0.00 Density 14.5 lb/ft3 Unibestos (ft3) 0.0 ft3 0.00 0.00 0.00 0.00 Density 14.5lb/ft' E-glass Fiberglass (ft3) 50.1 ft3 160.61 50.06 159.89 0.64 Density 4.0lb/ft3 NUKON (ft3) 1139.0 ft3 1234.02 1139.05 875.03 302.13 Density 2.4 lb/ft3 Temp-Mat (ft3) 0.0 ft3 0.00 0.00 0.00 0.00 Density 11.8 lb/ft3 Thermal Wrap (ft3) 0.0 ft3 0.00 0.00 0.00 0.00 Density 2.4lb/ft3 Silica Powder Microtherm (ft3) 0.0 ft' 0.00 0.00 0.00 0.00 Density 15.0 lb/ft3 Min-K (ft3) 0.0 ft3 0.00 0.00 0.00 0.00 Density 16.0 lb/ft' Mineral Wool Min-Wool (83) 0.0 ft3 0
0 0
0 Density 10.0 lb/ft' Rock Wool (ft3) 0.0 ft3 0
0 0
0 Density 10.0 lb/ft' Aluminum Silicate Cerablanket (ft3) 0.0 ft' 0
0 0
0 Density 12.0 lb/ft3 FiberFrax Durablanket (ft3) 0.0 ft3 0
0 0
0 Density 12.0 lb/ft3 Kaowool (ft3) 0.0 ft3 0
0 0
0 Density 12.0 lb/ft3 Mat-Ceramic (ft3) 0.0 ft' 0
0 0
0 Density 12.0 lb/ft' Mineral Fiber (ft3) 0.0 ft3 0
0 0
0 Density 21.0lb/ft' PAROC Mineral Wool (ft3) 0.0 ft3 0
0 0
0 Density 21.0 lb/ft3 Interam Interam (ft3) 0.0 ft3 0
0 0
0 Density 54.0 lb/ft'
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 286 of 492 Assume particulate debris is insulation in mass proportion to the insulation Density Break Si Break S2 Break S3 Break S4 (lb/ft)
CalSil ZOI 35.51 60.98 21.86 0.00 ft3 Unjacketed 50.78 50.78 50.78 50.78 ft3 Total 86.29 111.76 72.64 50.78 ft3 Weight 14.5 1,251.21 1,620.52 1,053.28 736.31 lb Marinite 12.80 12.80 12.80 12.80 ft3 Weight 46 588.80 588.80 588.80 588.80 lb Total Weight 1,840.01 2,209.32 1,642.08 1,325.11 lb 33.9%
43.1%
37.6%
64.9% Weight %
Asbestos ZOI 0.00 0.00 0.00 0.00 ft3 0.00 0.00 0.00 0.00 ft3 Total 0.00 0.00 0.00 0.00 ft3 10.0 0.00 0.00 0.00 0.00 lb 0.0%
0.0%
0.0%
0.0% Weight %
Total calcium silicate 1,840.01 2,209.32 1,642.08 1,325.11 lb Fiberglass Z10 159.14 49.18 158.21 0.04 ft3 Unjacketed 0.59 0.59 0.59 0.59 ft3 Total 159.73 49.77 158.80 0.63 53 4.0 638.92 199.08 635.20 2.52 lb 11.8%
3.9%
14.6%
0.1% Weight %
Temp-Mat ZOI ft3 ft3 Total 0.00 0.00 0.00 0.00 ft3 11.8 0.00 0.00 0.00 0.00 lb 0.0%
0.0%
0.0%
0.0% Weight %
Nukon ZOl 1,224.64 1,129.83 866.46
.295.17 ft3 Thermal Wrap Unjacketed 2.59 2.59 2.59 2.59 ft3 Total 1,227.23 1,132.42 869.05 297.76 ft3 2.4 2,945.35 2,717.81 2,085.72 714.62 lb 54.3%
53.0%
47.8%
35.0% Weight %
Total E-Glass 3,584.27 2,916.89 2,720.92 717.14 Ib
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 287 of 492 Microtherm Zol ft3 Margin ft3 Spray & Submerge ft3 Margin ft3 Total 0.00 0.00 0.00 0.00 ft3 15.0 0.00 0.00 0.00 0.00 lb 0.0%
0.0%
0.0%
0.0% Weight %
Total silica Powder 0.00 0.00 0.00 0.00 lb Mineral Wool Zol ft3 ft3 ft3 ft3 Total 0.00 0.00 0.00 0.00 ft3 10.0 0.00 0.00 0.00 0.00 lb 0.0%
0.0%
0.0%
0.0% Weight %
Cerafber ZOl ft3 ft3 ft3 ft3 Total 0.00 0.00 0.00 0.00 ft3 12.0 0.00 0.00 0.00 0.00 lb 0.0%
0.0%
0.0%
0.0% Weight %
Total debris insulation weight 5,424.28 5,126.21 4,363.00 2,042.25 lb Check sum 100.0%
100.0%
100.0%
100.0% Weight %
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 288 of 492 Latent Debris - Fiber 30 lb Break SI Break S2 Break S3 Break S4 Density (Ib/ft3)
CalSil Weight %
33.9%
43.1%
37.6%
64.9%
Weight fiber 14.5 10.18 12.93 11.29 19.47 lb Equivalent fiber volume 0.70 0.89 0.78 1.34 ft3 Asbestos Weight %
0.0%
0.0%
0.0%
0.0%
Weight fiber 10.0 0.00 0.00 0.00 0.00 lb Equivalent fiber volume 0.00 0.00 0.00 0.00 ft3 Fiberglass Weight %
11.8%
3.9%
14.6%
0.1%
Weight fiber 4.0 3.53 1.17 4.37 0.04 lb Equivalent fiber volume 0.88 0.29 1.09 0.01 ft3 Temp-Mat Weight %
0.0%
0.0%
0.0%
0.0%
Weight fiber 11.8 0.00 0.00 0.00 0.00 lb Equivalent fiber volume 0.00 0.00 0.00 0.00 ft3 Nukon Weight %
54.3%
53.0%
47.8%
35.0%
Weight fiber 2.4 16.29 15.91 14.34 10.50 lb Equivalent fiber volume 6.79 6.63 5.98 4.37 ft3 Microtherm Weight %
0.0%
0.0%
0.0%
0.0%
Weight fiber 15.0 0.00 0.00 0.00 0.00 lb Equivalent fiber volume 0.00 0.00 0.00 0.00 ft3 Mineral Wool Weight %
0.0%
0.0%
0.0%
0.0A Weightfiber 10.0 0.00 0.00 0.00 0.00 lb Equivalent fiber volume 0.00 0.00 0.00 0.00 ft3 Cerafiber Weight 0.0%
0.0%
0.0%
0.0%
Weight fiber 12.0 0.00 0.00 0.00 0.00 lb Equivalent fiber volume 0.00 0.00 0.00 0.00 ft3 Check
% TOTAL 100.00%
100.00%
100.00%
100.00%
Check Fiber total 30.00 30.00 30.00 30.00
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 289 of 492 Total Insulation volume Break S1 Break S2 Break S3 Break S4 ft3 ft3 ft3 ft3 CalSil Insulation 126.90 152. 37 113.25 91.39 Includes Matinite board Latent Debris 0.70 0.89 0.78 1.34 TOTAL 127.60 153.26 114.03 92.73 Asbestos Insulation 0.00 0.00 0.00 0.00 Latent Debris 0.00 0. 00 0.00 0.00 TOTAL
- 0. 00 0.00 0.00 0.00 Fiberglass Insulation 159.73 49.77 158. 80 0.63 Latent Debris 0.88 0.29 1.09 0.01 TOTAL 160. 61 50.06 159. 89 0.64 Temp-Mat Insulation 0.00 0.00 0.00 0.00 Latent Debris 0.00 0.00 0. 00 0.00 TOTAL 0.00 0.00 0. 00 0.00 Nukon Insulation 1227.23 1132. 42 869. 05 297.76 Latent Debris 6.79 6.63 5.98 4.37 TOTAL 1234.02 1139.05 875.03 302.13 Microtherm Insulation 0. 00 0.00 0.00 0.00 Latent Debris 0.00 0.00 0. 00 0.00 TOTAL
- 0. 00 0.00 0.00 0.00 Mineral Wool Insulation 0.00 0.00
- 0. 00 0.00 Latent Debris 0.00 0.00 0.00 0.00 TOTAL 0.00 0.00 0.00 0.00 Cerafiber Insulation 0.00 0.00 0.00 0.00 Latent Debris 0.00 0. 00 0.00 0.00 TOTAL 0.00 0.00 0. 00 0.00
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 290 of 492 GSI-191 Aluminum & Chemical Effects Evaluation Submerged Outside the Reactor Cavity Wetted Area (ft2)
Weight (Ib)
Area (52)
Service Water Piping 2433. 0 4866.0 547.0 Aluminum Paint 1365.0 2730.0 153.0 Aluminum Paint 107.0 214.0 3.0 Submerged Inside the Reactor Cavity Wetted Area
( ft2)
Weight (lb)
Area (ff2)
Reactor Vessel 10688.0 21376.0 98.0 RV Cavity Walls 907.0 1814.0 32.0 Reactor Cavity Cir. Panels 223.0 447.0 7.9 RV Insulation Supports 481.0 481. 0 379.0 Reactor Cavity Wall Supports 19.8 19. 8 338.0 Reactor Cavity Cir. Panel Supports 3.9 3.9 76.0 TOTAL (excluding paint )
29,007.70 1,477.90 Non-Submerged Outside the Reactor C avity
( Exposed to Containment Spray)
Wetted Area (ff2)
Weight (Ib)
Area (ft2)
Primary Coolant System 11,390. 0 22,781.0 160.0 Primary Coolant Pumps 19,467.0 38,934.0 273.0 Pressurizer Surge Line 3,128. 0 6,256.0 44.0 Pressurizer 799.0 1,597.0 28.0 Pressurizer 3,019.0 6,048. 0 48.0 Service Water Piping 962.0 1,923. 0 216.0 SIS Piping 3,271.0 6, 542.0 735.0 MSL Pipe 1
, 139. 0 2,279.0 256.0 FW Pipe 1
, 613.0 '-
3,226. 0 362.0 Miscellaneous Pipe 7,805. 0 15,609.0 1792.0 Pressurizer Jacket 487.0 974.0 269.0 Pressurizer Jacket 596.0 1,193.0 337.0 Pressurizer Supports 144.0 144.0 133.0 Component Cooling Fan Blades 252.0 504.0 473.0 Light Fixtures 368.0 735.0 630.0 Aluminum Paint 0.0 0.0 0.0
Entergy Palisades Nuclear Power Plant Project No. 12122-005 Aluminum Summary 108,745.0
% Aluminum in Reactor Cavity Available 100%
ft2 lb Thick Aluminum Metal Submerged (sq ft) 5,370.7 1,340.0 Thin Aluminum Metal Submerged (sq ft) 23,637.0 137.9 Total Aluminum in Paint Submerged (sq ft) 2,944.0 156.0 Aluminum Paint Submerged (sq ft) 2,944.0 156.0 Total Aluminum in Paint Submerged (sq ft) 2,944.0 156.0 Thick Aluminum Metal Not-Submerged (sq ft) 34,726.0 5,231.0 Thin Aluminum Metal Not-Submerged (sq ft) 74,019.0 525.0 Aluminum Paint Not-Submerged (sq ft) 0.0 0.0 Aluminum Submerged 31,951.7 1,633.9 Aluminum Not Submerged 108,745.0 5,756.0 Document No. 2007-03464 Revision 0 Page 291 of 492
Entergy Attachment I Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 292 of 492 Chemical-Effects Version 1.1, 8/31/2006 1.
Enter the pH and temperature vs. time profiles on the sheet "Time Temp pH input" a.
Replace the values in red
- b. Addition instructions are provided in the comments associated with the cells in row 1.
Place cursor over the red triangles to view.
2.
Enter containment materials in the sheet labeled "Materials Input" a.
For the insulation materials, input the quantities that are wetted by the spray, transported to the sump pool, or are submerged.
- b. Aluminum is separated into two categories: that submerged in the sump pool and that impacted by the spray.
c.
Both the mass and surface area of aluminum should be entered.
If the mass is not known, enter a very large number (1,000,000 Ibm) for conservatism
- 3. Change default density values in the sheet labeled "Materials Conversions" if the default estimates are not correct for your plant. Otherwise, no entries are needed.
- 4. View the results of model in the sheet labeled "Results Table" a.
Results are given as a function of time
- b. The elemental releases of Ca, Al and Si are given, as well as the masses of precipitates likely to form from them.
- 5. View a summary of the contribution of each material to the total elemental release in sheet "Releases by Material"
- 6. View a summary of the contribution of each material to each of the precipitates in the sheet "Precipitate by Material" 7.
Detailed information on the release of each material component with time is located in subsequent sheets that need not be examined.
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 293 of 492
Entergy Attachment I Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 294 of 492 5271 4.8 31951.7 1633.9 108745.0 5756.0 153.3 0.0 0.0 0.0 1139.0 06
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 295 of 492
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 296 of 492 Interval Duration (min)
Start of Interval (hrs)
End of Interval (hrs)
Average Interval pH Average Temp (F )
Ca Release (kg )
Si Release (kg)
AI Release (kg)
NaAISi3O8 Precipitate (kg)
AIOOH Precipitate (kg )
Ca3(PO4)2 Precipitate (kg) 0.2 0.00 0.0 11.54 239 0.0082 0.1375 1.1213 0.428 2.392 0.021 0.2 0.01 0.0 11.54 255 0.02 0.33 2.61 1.0 5.6 0.04 0.5 0.01 0.0 11.54 264 0.05 1.02 7.82 3.2 16.6 0.12 0.5 0.02 0.0 11.54 270 0.08 1.79 13.55 5.6 28.8 0.20 3.5 0.03 0.1 11.54 274.5 0.29 7.71 56.35 24.0 119.6 0.76 5.0 0.08 0.2 11.54 276 0.61 16.35 118.20 50.9 250.8 1.56 5.0 0.17 0.3 11.54 273 0.91 24.43 176.12 76.0 373.6 2.35 5.0 0.25 0.3 9.77 269.5 1.19 28.63 186.35 89.0 393.3 3.08 5.0 0.33 0.4 8
264.5 1.48 30.98 191.19 96.4 402.4 3.81 5.0 0.42 0.5 8
258 1.75 33.04 194.87 102.8 409.1 4.51 15.0 0.50 0.8 8
249 2.53 38.17 203.18 118.7 423.9 6.54 15.0 0.75 1.0 8
241 3.29 42.45 210.72 132.0 437.6 8.49 30.0 1.00 1.5 8
238.5 4.77 50.49 228.83 157.0 472.1 12.30 30.0 1.50 2.0 8
237 6.19 58.10 247.76 180.7 508.7 15.98 120.0 2.00 4.0 8
233.5 11.68 85.67 320.42 266.4 650.5 30.14 120.0 4.00 6.0 8
228 16.48 107.96 388.36 335.8 785.5 42.51 120.0 6.00 8.0 8
220.5 20.76 125.09 451.16 389.0 912.7 53.57 120.0 8.00 10.0 8
213 24.72 138.18 505.62 429.7 1024.3 63.77 120.0 10.00 12.0 8
208 28.43 148.88 550.75 463.0 1116.9 73.34 120.0 12.00 14.0 8
203 30.12 152.39 588.86 473.9 1199.0 77.71 120.0 14.00 16.0 8
198 31.97 155.61 621.36 483.9 1268.9 82.49 240.0 16.00 20.0 8
193 36.04 161.51 675.90 502.3 1385.8 92.98 240.0 20.00 24.0 8
187.5 40.35 166.80 721.89 518.8 1484.1 104.09 720.0 24.00 36.0 8
180 55.17 180.70 828.63 562.0 1711.2 142.35 720.0 36.00 48.0 8
170.5 70.15 192.01 903.79 597.2 1870.0 180.98 1440.0 48.00 72.0 8
162 101.59 210.93 1008.96 656.0 2090.1 262.09 2880.0 72.00 120.0 8
158 134.97 243.78 1172.18 758.2 2429.1 348.22 3240.0 120.00 174.0 8
153 142.85 273.50 1306.62 850.6 2706.4 368.56 3960.0 174.00 240.0 8
143.85 192.59 301.60 1410.62 938.0 2917.3 496.88 7200.0 240.00 360.0 8
136.85 213.73 336.92 1538.63 1047.8 3176.4 551.41 7200.0 360.00 480.0 8
132.15 238.74 336.92 1635.74 1047.
3392.0 615.95 7200.0 480.00 600.0 8
126.25 287.00 336.92 1707.27 1047.8 3550.8 740.45 7200.0 600.00 720.0 8
121.1 290.19 336.92 1763.19 1047.8 3674.9 748.69
Entergy Attachment I Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 297 of 492 KeleaseS In SI Metallic Aluminum Submerged 0.00 0.00
(
633.95 Metallic Aluminum Not-Submerged 0.00 0.00 1125.25 Calcium Silicate 233.60 242.93 0.00 E-Glass 13.87 92.57 3.52 Silica Powder 0.00 0.00 0.00 Mineral Wool 0.00 0.00 0.00 Aluminum silicate 0.00 0.00 0.00 Concrete 42.72 1.42 0.47 Interam 0.00 0.00 0.00 2000.00 1800.00 1600.00 1400.00 1200.00 S
1000.00 a
800.00 600.00 400.00 200.00 0.00 Contribution to Elemental Releases by Each Material III lnteram O Concrete Aluminum silicate O Mineral Wool Silica Powder 0 E-Glass 13 Calcium Silicate Metallic Aluminum Not-Submerged Metallic Aluminum Submerged Ca Si Al Element
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 298 of 492 rreclpliaie kKg )
Material Class Ca3(PO4)2 NaAlSi3O8 AIOOH Metallic Aluminum Submerg ed 0.00 188.37 1321.31 Metallic Aluminum Not-Submerg ed 0.00 334.35 2345.30 Calcium Silicate 602.69 377.76 0.00 E-Glass 35.77 144.99 7.33 Silica Powder 0.00 0.00 0.00 Mineral Wool 0.00 0.00 0.00 Aluminum silicate 0.00 0.00 0.00 Concrete 110.23 2.35 0.98 Interam 0.00 0.00 0.00 4000.00 3500.00 3000.00 2500.00 s
2000.00 N
1500.00 2
1000.00 500.00 0.00 Contributions to Precipitates by Material o Interam o Concrete E3 Aluminum silicate 13 Mineral Wool E3 Silica Powder q E-Glass Silicate 0 Metallic Aluminum Not-Submerged Metallic Aluminum Submerged Ca3(PO4)2 NaAlSi3O8 AIOOH Precipitate
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 299 of 492 onstants alue Interval Duration (min)
Start of Interval (hrs)
End of Interval (hrs)
Ave Interval pH Ave Temp (F) 000/f (K) a All Mat Ca this Mat Only a (ppm)
K k
R i,ositive release rate (mg/kg-interval pred release (kg)
Amount above start Mass interval kg Ca released Integral kg Ca released Mass Material (kg) 1008.0058 0.2 0.00 0.01 11.54 239 2.576323586 0
0 0.00 4.27 3.99 3.99 3.99 0.001
-347.8 0.001 0.0007 Mass Element (kg) 347.762 0.2 0.01 0.0 11.54 255 2.518644969 0.01 0.00 0.00 3.29 3.14 3.13 3.13 0.001
-347.8 0.001 0.00 a
-2.4063 0.5 0.01 0.0 11.54 264 2.487321569 0.01 0.00 0.00 2.86 2.75 2.75 2.75 0.001
-347.8 0.001 0.00 b
-0.1759 0.5 0.02 0.0 11.54 270 2.466868584 0.03 0.00 0.00 2.60 2.52 2.52 2.52 0.001
-347.8 0.001 0.00 c
1.96702 3.5 0.03 0.1 11.54 274.5 2.451748233 0.05 0.00 0.00 2.43 2.37 2.37 2.37 0.008
-347.7 0.008 0.01 d
-2.35331 5.0 0.08 0.2 11.54 276 2.446749222 0.20 0.01 0.01 2.38 2.32 2.31 2.31 0.012
-347.7 0.012 0,02 e
0.15044 5.0 0.17 0.3 11.54 273 2.456767713 0.41 0.02 0.02 2.49 2.42 2.40 2.40 0,012
-347.7 0.012 0.04 I f 1.82068 5.0 0.25 0.3 9.77 269,5 2.468560144 0.61 0.02 0.0 5.38 4.69 4.67 4.
77 0.024
-347.7 0,024 0,06 5.0 0.33 0.4 8
264.5 2.485604209 0.80 0.04 0.04 11.89 9.30 9.27 9.27 0,047
-347.7 0.047 0.11 5.0 0.42 0.5 8
258 2.508116544 0.99 0.07 0.07 13.17 10.23 10.17 10.17 0.051
-347.6 0.051 0.16 15.0 0.50 0.8 8
249 2.539969238 1.17 0.11 0.11 15.22 11.69 11.60 11.60 0.175
-347.4 0.175 0.33 15.0 0.75 1.0 8
241 2.5689697 1.70 0.22 0.22 17.35 13.20 13.03 13.03 0.197
-347.2 0.197 0.53 30.0 1.00 1.5 8
238.5 2.578168641 2.21 0.36 0.36 18.09 13.72 13.45 13.45 0.407
-346.8 0.407 0.94 30.0 1.50 2.0 8
237 2.583719695 3.20 0.63 0.63 18.55 14.04 13.56 13.56 0.410
-346.4 0.410 1.35 120.0 2.00 4.0 8
233.5 2.596765584 4.15 0.90 0.90 19.68 14.83 14.15 14.15 1.711
-344.7 1.711 3.06 120.0 4.00 6.0 8
228 2.617534573 7.83 2.05 2.05 21.62 16.18 14.64 14.64 1.771
-342.9 1.771 4.83 120.0 6.00 8.0 8
220.5 2.646397224 11.04 3.24 3,24 24.64 18.26 15,86 15.86 1.918
-341.0 1.918 6.75 120.0 8.00 10.0 8
213 2.675903489 13.92 4,52 4.52 28.16 20.66 17.34 17.34 2.098
-338.9 2.098 8.85 120.0 10.00 12.0 8
208 2.695942606 16.57 5.93 5,93 30.84 22.47 18.15 18.15 2.196
-336.7 2,196 11,04 120.0 12.00 14.0 8
203 2.716284123 19.05 7.40 19.05 33.81 24.47 10.68 10.68 1.292
-335.4 1.292 12.33 120.0 14.00 16.0 8
198 2.736934937 20.19 8.27 20.19 37.13 26.69 12.18 12.18 1.473
-334.0 1.473 13.81 240.0 16.00 20.0 8
193 2.757902156 21.43 9.25 21.43 40.83 29.14 13.84 13.84 3.349
-330.6 3.349 17.16 240.0 20.00 24.0 8
187.5 2.781340297 24.15 11.50 24.15 45.40 32.15 15.04 15.04 3.639
-327.0 3.639 20.79 720.0 24.00 36.0 8
180 2.813950943 27.04 13.94 27.04 52.63 36.85 17.92 17.92 13.004
-314.0 13.004 33.80 720.0 36.00 48,0 8
170.5 2.85637209 36.98 22.65 36.98 63.77 44.03 18.50 18,50 13.426
-300.5 13.426 47.23 1440.0 48.00 72.0 8
162 2.895426834 47.01 31.65 47.01 76.12 51.86 19.83 19.83 28.782
-271.8 28.782 76.01 2880.0 72.00 120.0 8
158 2.914177473 68.08 50.94 68.08 82.86 56.10 10.01 10,01 29,046
-242.7 29.046 105.05 3240.0 120.00 174.0 8
153 2.937960076 90.46 70.41 90.46 92.29 61.98 1.23 1.23 4.009
-238.7 4.009 109,06 3960.0 174.00 240.0 8
14185 2.982502651 95.74 73.09 95.74 112.91 74.71 11.36 11.36 45.355
-193.3 45.355 154.4 7200.0 240.00 360.0 8
136.85 3.017501509 129.07 103.49 129.07 132.31 86.52 1
2.12 2.1 15.356
-178.0 15.356 169.77 7200.0 360.00 480.0 8
132.15 3.04146531 143.24 113.78 143.24 147.48 95.66 2.75 2.75 19.948
-158.0 19.948 189.72 7200.0 480,00 600.0 8
126.25 3.072091753 160.01 127.15 160.01 169.42 108.76 6.05 6.05 43,879
-114,2 43.879 233.60 7200.0 600.00 720.0 8
121.1 3.099333643 192,35 156.56 192.35 191.67 121.92
-0.43 0.0 0.000
-114.2 0.000 233.60
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 300 of 492 onstants alue Interval Duration min Start of Interval hrs End of Interval hrs Ave Interval H
Ave Temp F
000lf K' i All Mat Si this Mat Only i (ppm )
K k
R osi ive release rate (m g/k g-interval pred release k
Amount above start Mass interval kg Si released Integral kg Si released Mass Material (kg)
Mass Element (kg) 1008.0058 242.92939 0.2 0.2 0,00 0.01 0.01 0,0 11.54 11.54 239 255 2.576323586 2.518644969 0
0.09 0
0.01 0.00 0.01 220,00 200.03 74.84 97.89 74.84 97.89 74.84 97.89 0.013 0.016
-242.9
-242.9 0.013 0.016 0.0126 0.0 a
0.12735 0.5 0.01 0.0 11.54 264 2.487321569 0.22 0.02 0.02 189.95 113.26 113.25 113.25 0.057
-242.8 0.057 0.1 b
0.03197 0.5 0.02 0.0 11.54 270 2.466868584 0.68 0.06 0.06 183.65 124.58 124.54 124.54 0.063
-242.8 0.063 0.1 c
0.71658 3,5 0.03 0.1 11.54 274.5 2.451748233 1.20 0.10 0,10 179.13 133.67 133.59 133.59 0.471
-242.3 0.471 0.6 d
7.5547 5.0 0.08 0.2 11.54 276 2.446749222 5.17 0.42 0.42 177.65 136.61 136.49 136.49 0.688
-241.6 0.688 1.3 e
-0.04084 5.0 0.17 0.3 11.54 273 2.456767713 10.96 0.88 0.88 180.62 130.58 129.94 129.94 0.655
-241.0 0.655 2.0
-2.02198 5.0 0.25 0.3 9.77 269,5 2.468560144 16.37 1.32 1.32 161.67 145.99 144.80 144.80 0.730
-240.2 0.730 2.7 5.0 0.33 0.4 8
264,5 2,485604209 19.19 1.80 1.80 145.96 159,27 157.30 157.30 0.793
-239.4 0,793 3.5 5.0 0.42 0.5 8
258 2.508116544 20.77 2.34 2.34 151.49 143,42 141.21 141.21 0.712
-238.7 0.712 4.2 15.0 0.50 0.8 8
249 2.539969238 22.15 2.81 2.81 159.66 123.66 121.48 121.48 1.837
-236.9 1.837 6.0 15,0 0,75 1.0 8
241 2.5689697 25.58 4.04 4.04 167.49 108.04 105.43 105.43 1.594
-235.3 1.594 7.6 30,0 1.00 1.5 8
238.5 2.578168641 28.45 5.11 5.11 170.05 103.51 100.40 100.40 3.036
-232.3 3.036 10.7 30.0 1.50 2.0 8
237 2.583719695 33.84 7.15 7.15 171.61 100.87 96.67 96.67 2.923
-229.3 2.923 13.6 120.0 2.00 4.0 8
233,5 2.596765584 38.94 9,11 9.11 175.35 94.92 89.99 89.99 10.886
-218,5 10.886 24.5 120.0 4.00 6.0 8
228 2.617534573 57.42 16,40 16.40 181.46 86,17 78.39 78.39 9.482
-209,0 9.482 34.0 120.0 6.00 8.0 8
220.5 2.646397224 72.36 22,76 22.76 190.31 75.34 66.33 66.33 8.023
-201.0 8.023 42.0 120.0 8.00 10.0 8
213 2.675903489 83.83 28.13 28.13 199.81 65.67 56.42 56.42 6.825
-194.1 6.825 48.8 120.0 10.00 12.0 8
208 2.695942606 92.61 32.71 32.71 206.52 59.82 50.35 50.35 6.090
-188.0 6.090 54.9 120.0 12.00 14.0 8
203 2.716284123 99.78 36.79 99.78 213.57 54.41 28.99 28.99 3.507
-184.5 3.507 58.4 120.0 14.00 16.0 8
198 2.736934937 102.13 39.14 102.13 220.97 49.43 26.58 26.58 3.215
-181.3 3.215 61.6 240,0 16.00 20.0 8
193 2.757902156 104.29 41.29 104.29 228.75 44.83 24.39 24,39 5.901
-175.4 5.901 67.5 240.0 20.00 24.0 8
187.5 2.781340297 108.24 45.25 108.24 237.77 40.19 21.90 21.90 5.297
-170.1 5.297 72.8 720.0 24.00 36.0 8
180 2.813950943 111.79 48.80 111.79 250.92 34.53 19.15 19.15 13.896
-156.2 13.896 86.7 720,0 36.00 48.0 8
170.5 2.85637209 121.11 58,11 121.11 269.11 28.34 15.59 15,59 11.313
-144.9 11.313 98.0 1440,0 48,00 72.0 8
162 2.895426834 128.69 65.70 128.69 287.02 23.63 13.04 13,04 18.922
-126.0 18.922 116.9 2880.0 72.00 120.0 8
158 2.914177473 141.37 78.38 141.37 296.04 21.66 11.31 11.31 32.846
-93.1 32.846 149.8 3240.0 120.00 174.0 8
153 2.937960076 163.38 100.39 163.38 307.89 19.39 9.10 9,10 29.715
-63.4 29.715 179.5 3960.0 174.00 240.0 8
143,85 2.982502651 183.30 120.31 183.30 331.37 15,76 7.04 7.04 28.101
-35,3 28.101 20.6 7200.0 240.00 360.0 8
136.85 3.017501509 202.13 139.14 202,13 351.07 13.39 5.68 5.68 41.215 5.9 35.323 242.9 7200.0 360.00 480.0 8
132.15 3.04146531 225.81 162.81 225.81 365.23 11,97 4.57 4.57 33.171 33.2 0.000 242.9 7200.0 480.00 600.0 8
126.25 3.072091753 225.81 162.81 225.81 384.16 10.38 4.28 4.28 31.058 31.1 0,000 242.9 7200,0 60 0.00 720.0 8
121.1 3.099333643 225.81 162.81 225.81 401.82 9.15 4.01 4.01 29.073 29.1 0.000 242.9
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 301 of 492 onstants Mass Material (kg)
Mass Element (kg) alue 77.717619 1000000 Interval Duration min 0.2 0,2 Start of Interval hrs 0.00 0.01 End of Interval hrs 0.01 0.0 Ave Interval H
11.54 11.54 Ave Temp F
239 255 000rr K' 2.576323586 2.518644969 a All Mat 0
0.01 Ca this Mat Cnl 0
0,00 a (ppm) 0.000 0.000 K
59.70 52.59 k
39.96 46.30 R
39.96 46.30 osi ive release rate m
/k 39.96 46.30 interval pred release k
0.001 0.001 Amount above start Mass
-1000000
-1000000 interval kg Ca released 0.001 0.001 Integral kg Ca released 0.001 0.001 a
-0.15969 0.5 0.01 0.0 11.54 264 2.487321569 0.01 0.00 0.001 49.09 50.15 50.15 50.15 0.002
-1000000 0.002 0.003 b
-0.04542 0.5 0.02 0.0 11.54 270 2.466868584 0.03 0.00 0.002 46.93 52.83 52.83 52.83 0.002
-1000000 0,002 0.005 c
0.95477 3.5 0.03 0.1 11.54 274.5 2.451748233 0.05 0.00 0.003 45.40 54.91 54.91 54.91 0.015
-1000000 0,015 0.020 d
5.31705 5.0 0.08 0.2 11.54 276 2.446749222 0.20 0.01 0.013 44.90 55.62 55.60 55.60 0.022
-1000000 0.022 0.042 e
-0.07459 5.0 0.17 0.3 11,54 273 2.456767713 0.41 0.03 0.028 45.90 54.21 54.18 54.18 0.021
-1000000 0.021 0.063 f
-1.10803 5.0 0.25 0.3 9.77 269.5 2.468560144 0.61 0.04 0.042 56.68 71.30 71.24 71.24 0.028
-1000000 0.028 0.090 5.0 0.33 0.4 8
264.5 2.485604209 0.80 0.06 0.061 70.82 92.51 92.43 92.43 0.036
-1000000 0.036 0.126 5.0 0.42 0.5 8
258 2.508116544 0.99 0.08 0.085 74.41 87.35 87.25 87.25 0.034
-1000000 0.034 0.160 15,0 0.50 0.8 8
249 2.539969238 1.17 0.11 0.107 79.81 80.53 80.42 80.42 0.094
-1000000 0.094 0.254 15.0 0.75 1.0 8
241 2.5689697 1.70 0.17 0.170 85.06 4.79 74.64 74.64 0.087
-1000000 0.087 0.341 Note=
Large mass of element u 30.0 1.00 1.5 8
238.5 2.578168641 2.21 0.23 0.229 86.80 73.05 72.86 72.86 0.170
-999999 0.170 0.511 because no limit to concrete ass 30.0 1.50 2.0 8
237 2.583719695 3.20 0.34 0,342 87.86 72.03 71.75 71.75 0.167
-999999 0.167 0.678 mass is an exposed surface.
If concrete in latent debris is bei 120.0 120.0 2.00 4.00 4.0 6,0 8
8 233.5 228 2.596765584 2.617534573 4.15 7.83 0.45 0.89 0.454 0.888 90.42 94.64 69.67 66.07 69.32 65.45 69.32 65.45 0.646 0.610
-999999
-999998 0,646 0.610 1.325 1.935 included, a fraction of B2 should 120.0 6.00 8.0 8
220.5 2.646397224 11.04 1.30 1.297 100.84 61.38 60,59 60.59 0.565
-999997 0.565 2.500 used.
120.0 8.00 10.0 8
213 2.675903489 13.92 1.68 1.676 107.60 56.93 56.04 56.04 0.523
-999997 0.523 3.023 120.0 10.00 12.0 8
208 2.695942606 16.57 2.03 2.026 112.45 54.09 53.12 53.12 0.495
-999996 0.495 3.518 120.0 12.00 14.0 8
203 2.716284123 19.05 2.36 19.051 117.59 51.36 43.04 43.04 0.401
-999996 0.401 3.920 120.0 14.00 16.0 8
196 2.736934937 20.19 2.63 20.186 123.05 48.72 40.73 40.73 0.380
-999996 0.380 4.299 240.0 16.00 20.0 8
193 2.757902156 21.43 2,88 21.428 128.86 46.18 38.50 38.50 0.718
-999995 0.718 5.018 240.0 20.00 24.0 8
187.5 2.781340297 24.15 3.36 24.154 135.67 43.50 35.76 35.76 0.667
-999994 0.667 5.685 720.0 24.00 36.0 8
180 2.813950943 27.04 3.81 27.040 145.76 40,03 32.60 32.60 1.824
-999992 1.824 7.509 720.0 1440.0 36.00 48.00 48.0 72.0 8
8 170,5 162 2.85637209 2.895426834 36.98 47.01 5,03 6.07 36.979 47.013 160.00 174.35 35.92 32.52 27.62 23.75 27.62 23.75 1.546 2.658
-999991
-999988 1.546 2.658 9.055 11.712 2880.0 72.00 120.0 8
158 2.914177473 68.08 7.85 68.084 181.69 31.00 19.38 19.38 4.338
-999984 4.338 16.051 3240.0 120,00 174.0 8
153 2.937960076 90.46 10.76 90,458 191.44 29.17 15.39 15.39 3.875
-999980 3.875 19,925 3960.0 174.00 240.0 8
143.85 2.982502651 95.74 13.35 95.742 211.13 26.04 14.23 14.23 4.380
-999976 4.380 24.305 7200.0 240.00 360.0 8
136.85 3.017501509 129.07 16.29 129.075 228.02 23.81 10.33 10.33 5.783
-999970 5, 783 30.088 7200.0 360.00 480.0 8
132,15 3.04146531 143.24 20.17 143.242 240,35 22.40 9.05 9.05 5.065
-999965 5.065 35.153 7200.0 480.00 600.0 8
126.25 3.072091753 160.01 23.56 160.006 257.09 2072 7.82 7.82 4.378
-999960 8
4.37 39.531 7200.0 600.00 720.0 8
121.1 1
3.099333643 192.35 26.49 192.349 272.96 19.33 5.71 5.71 3.194
-999957 3194 42.725
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 302 of 492 onstants Mass Material (kg)
Mass Element (kg) alue 77.717619 1000000 Interval Duration min 0.2 0.2 Start of Interval hrs 0.00 0,01 End of Interval hrs 0.01 0.0 Ave Interval H
11.54 11.54 Ave Temp F
239 255 000/i K' 2.576323586 2.518644969 i All Mat 0
0.09 Si this Mat Only 0
0.00 i (ppm) 0.00 0.00 K
34.10 33.56 k
24.53 27.07 R
24.53 27.07 Positive release rate (m g/kg-24.53 27.07 interval pred release k
0.000 0.000 Amount above start Mass
-1000000
-1000000 interval kg Si released 0.000 0.000 Integral kg Si released 0.0003 0.00 a
1.05597 0.5 0.01 0.0 11.54 264 2.487321569 0.22 0.00 0.00 33.28 28.56 28.56 28.56 0.001
-1000000 0.001 0.00 b
0.01483 0.5 0.02 0.0 11.54 270 2.466868584 0.68 0.00 0.00 33.09 29.58 29,58 29.58 0.001
-1000000 0.001 0.00 c
0.11862 3,5 0.03 0.1 11.54 274.5 2.451748233 1.20 0.00 0.00 32.96 30.36 30.35 30.35 0.008
-1000000 0.008 0,01 d
3.50061 5,0 0.08 0.2 11.54 276 2.446749222 5.17 0.01 0.01 32.91 30.62 30,61 30.61 0.012
-1000000 0.012 0.02 I s
-0.01713 5.0 0.17 0.3 11.54 273 2.456767713 10.96 0.02 0.02 33.00 30.10 30.08 30.08 0.012
-1000000 0.012 0.03 I f
-0.74261 5.0 0.25 0.3 9.77 269.5 2.468560144 16.37 0.02 0.02 31.17 31,63 31.60 31.60 0.012
-1000000 0.012 0.05 5.0 0.33 0.4 8
264.5 2.485604209 19.19 0.03 0.03 29.47 32.94 32.91 32,91 0.013
-1000000 0.013 0.06 5.0 0.42 0.5 8
258 2.508116544 20.77 0.04 0.04 29.66 31.70 31.65 31.65 0.012
-1000000 0.012 0.07 15.0 0,50 0.8 8
249 2.539969238 22.15 0.05 0.05 29,92 30.02 29.97 29.97 0.035
-1000000 0.035 0.11 15.0 0.75 1.0 8
241 2.5689697 25.58 0.07 0.07 30.15 28.56 28.50 28.50 0.033
-1000000 0.033 0.14 Note=
Large mass of element u 30.0 1.00 1.5 8
238.5 2.578168641 28.45 0.09 0.09 30.23 28.12 28.03 28.03 0.065
-1000000 0.065 0.21 because no limit to concrete ass 30.0 1.50 2.0 8
237, 2.583719695 33.84 0.14 0.14 30.28 27.85 27.73 27.73 0.065
-1000000 0.065 0,27 mass is an exposed surface.
120.0 2.00 4.0 8
233.5 2.596765584 38.94 0.18 0.18 30.38 27.24 27.08 27.08 0.253
-999999 0.253 0.52 If concrete in latent debris is bei 120.0 4.00 6.0 8
228 2.617534573 57.42 0.35 0.35 30.56 26.29 25.99 25.99 0.242
-999999 0.242 0.77 included, a fraction of B2 should 120,0 6.00 8.0 8
220,5 2.646397224 72.36 0.51 0.51 30.80 25.02 24.61 24.61 0.229
-999999 0.229 0.99 used.
120.0 120.0 8.00 10.00 10.0 12.0 8
8 213 208 2.675903489 2.695942606 83.83 92.61 0.67 0.81 0.67 0.81 31.05 31.22 23.79 22.99 23.28 22.39 23.28 22.39 0.217 0.209
-999999
-999999 0.217 0.209 1.21 1.42 120.0 12.00 14.0 8
203 2.716284123 99.78 0.95 99.78 31.39 22.20
-48.37 0.00 0.000
-999999 0.000 1.42 120.0 14.00 16.0 8
196 2.736934937 102.13 0.95 102.13 31.57 21.43
-47.91 0.00 0.000
-999999 0.000 1.42 240.0 16.00 20.0 8
193 2.757902156 104.29 0.95 104.29 31.75 20,68
-47.24 0.00 0.000
-999999 0.000 1.42 240.0 20.00 24.0 8
187,5 2.781340297 108.24 0.95 108.24 31.95 19.87
-47.43 0.00 0.000
-999999 0.000 1.42 720.0 24.00 36.0 8
180 2,813950943 111.79 0.95 111.79 32.24 18,79
-46.36 0.00 0.000
-999999 0,000 1.42 720.0 1440.0 36.00 48.00 48.0 72.0 8
8 170.5 162 2.85637209 2,895426834 121.11 128.69 0.95 0.95 121.11 128.69 32.62 32.97 17.47 16,35
-47.41
-47.46 0,00 0,00 0.000 0.000
-999999
-999999 0.000 0.000 1.42 1.42 2880.0 72.00 120.0 8
158 2.914177473 141.37 0.95 141.37 33.14 15.83
-51.71 0.00 0.000
-999999 0.000 1.42 3240.0 120.00 174.0 8
153 2.937960076 163.38 0.95 163.38 33.35 15.20
-59.26 0.00 0.000
-999999 0.000 1.42 3960.0 174.00 240.0 8
143.85 2.982502651 183.30 0.95 183.30 33.76 14.08
-62.39 0.00 0,000
-999999 0.000 1.42 7200.0 240.00 360.0 8
136.85 3.017501509 202.13 0.95 202.13 34.08 13.27
-65.41
.00 0.000
-999999 0.000 1.42 7200.0 360.00 480.0 8
132.15 3.04146531 225.81 0.95 225.81 34.31 12.73
-71.08 0.00 0
2 02
-999999 0.000 1.42 7200.0 480.00 600.0 8
126.25 3.072091753 225.81 0.95 225.81 34.60 12,08
-66.79 0.00 61 06 0 1
-999999 0.000 1.42 7200.0 600.00 720.0 8
121.1 3.099333643 225.81 0.95 225.81 34.85 11.53
-63.19 0.00 0.000
-999999 0.000 1.42
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 303 of 492 onstants Mass Material (k alue 77.717619 Interval Duration min 0.2 Start of Interval hrs 0,00 End of Interval hrs 0.01 Ave Interval H
11.54 Ave Temp F
239 00011 K) 2.576323586 l All Mat 0
Al this Mat Onl y 0
I (ppm )
0.00 K
20.58 k
17.44 R
17.44 osi rve release rate (m g/kg-17.44 interval pred release k
0.000 Amount above start Mass
.1000000 interval kg Al released 0.000 Integral kg Al released 0.0002 Mass Element (kg) 1000000 0.2 0.01 0.0 11.54 255 2.518644969 0.75 0.00 0.00 22.61 27.20 27.20 27.20 0.000
-1000000 0.005 0.00 a
b 2.35338 0.06829 0.5 0.5 0.01 0.02 0.0 0.0 11.54 11.54 264 270 2.487321569 2.466868564 1.75 5.24 0.00 0.00 0.00 0.00 23.80 24.61 34.63 40.53 34.62 40.53 34.62 40.53 0.001 0.002
-1000000
-1000000 0.001 0,002 0.00 0.00 C
-0.70953 3.5 0.03 0.1 11.54 274.5 2.451748233 9.08 0.00 0.00 25.23 45.54 45.54 45.54 0.012
-1000000 0.012 0.02 d
9.23778 5.0 0.08 0.2 11.54 276 2.446749222 37.77 0.01 0.01 25.43 47.33 47.31 47.31 0.018
-1000000 0.018 0.03 e
0.05404 f
-3.34577 5.0 5.0 5.0 5.0 0.17 0.25 0.33 0.42 0.3 0.3 0.4 0.5 11.54 9.77 8
8 273 269.5 264.5 258 2.456767713 2.468560144 2.485604209 2.508116544 79.22 118.04 124.89 128.14 0.02 0.03 0.04 0.05 0.02 0,03 0,04 0.05 25.02 18.58 13.68 13.19 43.81 32.10 22.59 18.99 43.77 32,04 22.52 18.92 43.77 32.04 22.52 18.92 0.017 0.012 0.009 0.007
-1000000
-1000000
-1000000
-1000000 0.017 0.012 0.009 0.007 0.05 0.06 0.07 0.08 15,0 0.50 0.8 8
249 2.539969238 130.61 0.05 0.05 12.52 14.86 14.79 14.79 0.017
-1000000 0.017 0.10 15.0 0.75 1.0 8
241 2.5689697 136.17 0.07 0.07 11.94 11.88 11.82 11.82 0.014
-1000000 0.014 0.11 Note= Large mass of element u 30.0 1.00 1.5 8
238.5 2.578168641 141.23 0.07 0.07 11.76 11.07 11.00 11.00 0.026
-1000000 0.026 0.14 because no limit to concrete ass 30.0 1.50 2.0 8
237 2.583719695 153.36 0.09 0,09 11.65 10.61 10.52 10.52 0.025
-1000000 0.025 0.16 mass is an exposed surface.
120.0 2.00 4.0 8
233.5 2.596765584 166.05 0.11 0.11 11.41 9.59 9.50 9.50 0.089
-1000000 0.089 0.25 If concrete in latent debris is bei 120.0 4.00 6.0 8
228 2.617534573 214.75 0.17 0.17 11.03 8.17 8.05 8.05 0.075
-1000000 0.075 0.32 included, a fraction of 92 should 120.0 6.00 8.0 8
220,5 2.646397224 260.28 0.22 0.22 10.52 6.54 6.41 6.41 0.060
-1000000 0.060 0.38 used.
120.0 8.00 10.0 8
213 2.675903489 302.37 0.26 0.26 10.02 5.21 5.08 5.08 0.047
-1000000 0.047 0.43 120.0 10.00 12.0 8
208 2.695942606 338.87 0.29 0.29 9.70 4.47 4.33 4.33 0.040
-1000000 0.040 0.47 120.0 12.00 14.0 8
203 2.716284123 369.12 0.32 369.12 9.38 3.82
-146.42 0.00 0.000
-1000000 0.000 0.47 120.0 14.00 16.0 8
198 2.736934937 394.66 0.32 394.66 9.07 3.26
-138.45 0.00 0.000
-1000000 0.000 0.47 240.0 16.00 20.0 8
193 2.757902156 416.44 0.32 416.44 8.77 2.77
-128.89 0.00 0.000
-1000000 0.000 0.47 240.0 20.00 24.0 8
187.5 2.781340297 452.99 0.32 452.99 8.44 2.31
-121.91 0.00 0.000
-1000000 0.000 0.47 720.0 24.00 36.0 8
180 2.813950943 483.82 0.32 483.82 8.00 1.80
-107.05 0.00 0.000
-1000000 0.000 0.47 720.0 1440.0 36.00 48.00 48.0 72.0 8
8 170.5 162 2.85637209 2.895426834 555.36 605.73 0.32 0.32 555.36 605.73 7.46 7.00 1.30 0.96
-95.28
-82.15 0.00 0.00 0.000 0.000
-1000000
-1000000 0.000 0.000 0.47 0.47 2880.0 72.00 120.0 8
158 2,914177473 676.22 0.32 676.22 6.79 0.83
-81.97 0.00 0.000
-1000000 0.000 0.47 3240.0 120.00 174.0 8
153 2.937960076 785.61 0.32 785.61 6.53 0.69
-82.57 0.00 0.000
-1000000 0.000 0.47 3960.0 174.00 240.0 8
143.85 2.982502651 875.72 0.32 875.72 6.07 0.49
-70.33 0.00 0.000
-1000000 0.000 0.47 7200.0 24 N 2 360.0 8
136.8 3.017501509 945.41 0.32 945.41 5.74 0.38
-61.45
.00 0.000
-1000000 0.000 0.47 7200.0 36 00 1 480.0 8
132.1 3.04146531 1031.21 0.32 1031.21 5.52 0.31
-57.99 0.00 0.000
-1000000 0.000 0.47 7200.0 480.00 600.0 8
126.25 3.072091753 1096.29 0.32 1096.29 5.25 0.25
-51.22 0.00 0.000
-1000000 0.000 0.47 7200.0 600.00 720.0 8
121.1 3.099333643 1144.23 0.32 1144.23 5.02 0.20
-45.33 NO 0.000
-1000000 0.000 0.47
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 304 of 492 onstants alue Interval Duration min Startof Interval hrs End of Interval hrs Ave Interval H
Ave Temp F
000(r (K' )
a All Mat Ca this Mat Only a (ppm )
K k
R osi ive release rate m
/k interval pred release k
Amount above start Mass interval kg Ca released Integral kg Ca released Mass Material (kg)
Mass Element (kg) 1330.8348 28.746032 0,2 0,2 0.00 0,01 0.01 0.0 11.54 11.54 239 255 2.576323586 2.518644969 0
0.01 0
0.00 0.00 0.00 25.32 26,96 31.61 35.92 31.61 35.91 31.61 35.91 0.007 0.008
-29
-29 0.0070 0.0080 0.01 0.01 a
1'.82949 0.5 0,01 0.0 11.54 264 2.487321569 0.01 0.01 0.01 27.89 38.50 38.48 38.48 0.026
-29 0.0256 0.04 b
0.06821 0.5 0.02 0.0 11.54 270 2.466868584 0.03 0.03 0.03 28.51 40.28 40.24 40.24 0.027
-29 0.0268 0.07 c
-0.47088 3.5 0.03 0.1 11.54 274.5 2.451748233 0.05 0.05 0.05 28.98 41.65 41.59 41.59 0.194
-28 0.1937 0.26 d
3.67611 5.0 0.08 0.2 11.54 276 2.446749222 0.20 0.17 0.17 29.14 42.12 41.86 41.86 0.279
-28 0.2786 0.54 e
0.02616 5.0 0.17 0.3 11.54 273 2.456767713 0.41 0.36 0.36 28.83 41.19 40.67 40.67 0.271
-28 0.2707 0.81 f
-0.96191 5.0 0.25 0.3 9.77 269.5 2.468560144 0.61 0.54 0.54 21.55 36.07 35.16 35.16 0.234
-28 0,2340 1.04 5.0 0.33 0.4 8
264.5 2.485604209 0.80 0.70 0.70 16.02 31.22 29.86 29.86 0.199
-28 0.1987 1.24 5.0 0.42 0.5 8
258 2.508116544 0.99 0.83 0.83 15.64 29.70 28.12 28.12 0.187
-27 0.1871 1,43 15,0 0.50 0.8 8
249 2.539969238 1.17 0.96 0.96 15.11 27.68 25.92 25.92 0.518
-27 0.5175 1.95 15.0 0.75 1.0 8
241 2.5689697 1.70 1.31 1.31 14.64 25.96 23.64 23.64 0.472
-26 0.4720 2.42 30.0 1.00 1.5 8
238.5 2.578168641 2.21 1.62 1.62 14.49 25.43 22.59 22.59 0.902
-25 0.9019 3.32 30.0 1.50 2.0 8
237 2.583719695 3.20 2.23 2.23 14.41 25.12 21.24 21.24 0.848
-25 0.8481 4.17 120,0 2.00 4.0 8
233.5 2.596765584 4.15 2.79 2.79 14.20 24.41 19.61 19.61 3.131
-21 3,1311 7.30 120,0 4.00 6.0 8
228 2.617534573 7,83 4.89 4.89 13,89 23.31 15.10 15.10 2.411
-19 2.4111 9,71 120.0 6.00 8.0 8
220.5 2.646397224 11.04 6.51 6.51 13.46 21.87 11.29 11.29 1.803
-17 1.8034 11.52 120.0 8.00 10.0 8
213 2.675903489 13.92 7.72 7.72 13.04 20.48 8.36 6.36 1.335
-16 1.3346 12.85 120.0 10.00 12.0 8
208 2.695942606 16.57 8.61 8.61 12.76 19.59 6.37 6.37 1.017
-15 1.0165 13.87 120.0 12.00 14.0 8
203 2.716284123 19.05 9.29 19.05 12.48 18.73
-9.87 0.00 0.000
-15 0.0000 13.87 120.0 14,00 16.0 8
198 2.736934937 20.19 9.29 20.19 12.20 17.89
-11.71 0.00 0.000
-15 0.0000 13.87 240.0 16.00 20.0 8
193 2.757902156 21.43 9.29 21,43 11.93 17.08
-13,61 0.00 0,000
-15 0.0000 13.87 240.0 20.00 24.0 8
187.5 2.781340297 24.15 9.29 24.15 11.63 16.22
-17.47 0.00 0.000
-15 0.0000 13.87 720.0 24.00 36.0 8
180 2.813950943 27.04 9.29 27.04 11.22 15.09
-21.26 0.00 0.000
-15 0.0000 13.87 720.0 36.00 48.0 8
170.5 2.85637209 36.98 9.29 36.98 10.72 13.73
-33.65 0.00 0,000
-15 0.0000 13.87 1440.0 48.00 72.0 8
162 2.895426834 47.01 9.29 47.01 10.27 12.60
-45.04 0.00 0,000
-15 0.000 13.87 2880.0 72.00 120.0 8
158 2.914177473 68.08 9.29 68.08 10.07 12.08
-69.63 0.00 0.000
-15 0.000 13.87 3240.0 120.00 174.0 8
153 2.937960076 90.46 9.29 90.46 9.81 11.46
-94.23 0.00 0.000
-15 0.000 13.87 3960.0 174.00 240.0 8
143.85 2.982502651 95.74 9.29 95.74 9.35 10.39
-95.98 0.00 0.000
-15 0.000 13.87 7200.0 240,00 360.0 8
136.85 3.017501509 129.07 9.29 129.07 9.11 9.61
-128.23 0.00 0.000
-15 0.000 13.87 7200.0 360.00 480.0 8
132.15 3.04146531 143.24 9.29 143.24 8.77 9.12
-139.77 0.00 0.000
-15 0.000 13.87 7200.0 480.00 600.0 8
126.25 3.072091753 160.01 9.29 160.01 8.48 8.52
-152.13 0.00 0.000
-15 0.000 13.87 7200.0 600,00 720,0 8
121.1 3.099333643 192.35 9,29 192.35 8.24 8,02
-179.24 0.00 0.000
-15 0.000 13.87
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 305 of 492 onstants alue Interval Duration min Start of Interval hrs End of Interval hrs Ave Interval H
Ave Temp (F) 000Ir K) i All Mat Si this Mat Only i (ppm)
K k
R Positive release rate m
/k interval pred release k
Amount above start Mass interval kg Si released Integral kg Si released Mass Material k
1330,835 0.2 0.00 0.01 11.54 239 2.576323586 0
0 0.00 333.51 561.62 561.62 561.62 0.125
-261 0.125 0.1246 Mass Element (kg) 260.9767 0,2 0.01 0.0 11.54 255 2.518644969 0.09 0.08 0.08 407.33 788.85 788.68 788.68 0.175
-261 0.175 0.30 a
5.20122 0.5 0.01 0.0 11.54 264 2.487321569 0.22 0.20 0.20 454.05 948.68 948.27 948.27 0.631
-260 0.631 0.93 b
0.10404 0.5 0.02 0.0 11.54 270 2.466868584 0.68 0.62 0.62 487.41 1070.15 1068.78 1068.78 0.711
-259 0.711 1.64 c
-1.50553 3.5 0.03 0.1 11.54 274.5 2.451748233 1.20 1.10 1.10 513.64 1169.83 1167.33 1167.33 5.437
-254 5.437 7.08 d
7.46511 5.0 0.08 0.2 11.54 276 2.446749222 5.17 4.74 4.74 522.62 1204.79 1193.85 1193.85 7.944
-246 7.944 15.02 e
f 0.16247
-2.55813 5.0 5.0 0.17 0.25 0.3 0.3 11.54 9.77 273 269,5 2.456767713 2.468560144 10.96 16.37 10.07 15.03 10.07 15.03 504.78 317.10 1135.75 546.44 111110 520.54 1113.10 520.54 7.407 3.464
-239
-235 7.407 3.464 22.43 25,89 5.0 0.33 0.4 8
264.5 2.485604209 19.19 17.35 17.35 195.61 254.90 232.29 232.29 1.546
-234 1.546 27.44 5.0 0.42 0.5 8
258 2.508116544 20.77 18.39 18.39 180.92 223.25 200.55 200.55 1.335
-232 1.335 28.77 15,0 0.50 0.8 8
249 2.539969238 22.15 19.28 19.28 162.01 185.05 163.03 163,03 3.254
-229 3.254 32.03 15.0 0.75 1.0 8
241 2.5689697 25.58 21.47 21.47 146.51 156.00 133.14 133,14 2.658
-226 2.658 34.69 30.0 1.00 1.5 8
238.5 2.578168641 28.45 23.25 23.25 141.92 147.77 123.56 123.56 4.933
-221 4.933 39.62 30.0 1.50 2.0 8
237 2.583719695 33.84 26.55 26.55 139.21 143.01 115.74 115.74 4.621
-217 4.621 44.24 120.0 120.0 2.00 4.00 4.0 6.0 8
8 233.5 228 2.596765584 2.617534573 38.94 57.42 29.65 40.67 29.65 40.67 133.06 123.81 132.44 117.19 102.92 78.70 102.92 78.70 16.437 12.568
-200
-188 16.437 12.568 60,68 73,24 120.0 6.00 8.0 8
220.5 2.646397224 72.36 49.09 49.09 112.02 98.86 55.54 55.54 8.870
-179 8.870 82.11 120.0 8.00 10.0 8
213 2.675903489 83.83 55.03 55.03 101.13 83.09 37.87 37.87 6.049
-173 6.049 88.16 120.0 10.00 12.0 8
208 2.695942606 92.61 59.09 59.09 94.34 73.84 27.59 27.59 4.40
-168 4.407 92.57 120.0 12.00 14.0 8
203 2.716284123 99.78 62.04 99.78 87.92 65.50
-8.84 0.00 0.000
-168 0.000 92.57 120.0 14.00 16.0 8
198 2.736934937 102.13 62.04 102.13 81.85 58.00
-14.38 0.00 0.000
-168 0.000 92.57 240.0 16.00 20.0 8
193 2.757902156 104.29 62.04 104.29 76.11 51.26
-18.98 0,00 0.000
-168 0.000 92.57 240,0 20.00 24.0 8
187.5 2.781340297 108.24 62.04 108.24 70,17 44.65
-24.23 0.00 0.000
-168 0.000 92.57 720.0 24.00 36.0 8
180 2.813950943 111.79 62.04 111.79 62.67 36.85
-28.88 0.00 0.000
-168 0.000 92.57 720.0 36.00 48.0 8
170.5 2.85637209 121.11 62.04 121.11 54.10 28.70
-35.55 0.00 0.000
-166 0.000 92.57 1440.0 48.00 72.0 8
162 2.895426834 128.69 62.04 128.69 47.25 22.80
-39.30 0,00 0.000
-168 0.000 92.57 2880.0 72.00 120.0 8
158 2.914177473 141.37 62.04 141.37 44.27 20.42
-44.78 0.00 0.000
-168 0.000 92.57 3240.0 120.00 174.0 8
153 2.937960076 163.38 62.04 163.38 40.77 17.75
-53.38 0.00 0.000
-168 0.000 92.57 3960.0 174.00 240.0 8
143.85 2.982502651 183.30 62,04 183.30 34.94 13.65
-57.98 0.00 0.000
-168 0.000 92.57 7200.0 240.02 360.0 8
136.85 3.017501509 202.13 62.04 202.13 30.95 11.11
-61.46 0.00 0.000
-168 0.000 92.57 7200.0 360.00 480.0 8
132.15 3.04146531 225.81 62.04 225.81 28.48 9.65
-66.85 0.0 0.000
-168 0.000 92.57 7200.0 480.00 600.0 8
126.25 3.072091753 225.81 62.04 225.81 25.61 8.05
-62.97 0,00 0.000
-168 0.000 92.57 7200.0 600.00 720.0 8
121.1 3.099333643 225.81 62.04 225.81 23.30 6.86
-59.62 0,00 0.000
-168 0.000 92.57
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 306 of 492 Constants Value Interval Duration min Start of Interval hrs End of Interval hrs Ave Interval H
Ave Temp F
1000/T (K )
Al All Mat Al this Mat Onl y AI (ppm)
K k
R Positive release rate (m g/kg-min interval pred release k
Amount above start Mass interval kg Al released Integral kg At released Mass Material (kg) 1330.835 0.2 0.00 0.01 11,54 239 2.576323586 0
0 0.00 9.54 36,22 36.22 36,22 0.008
-26 0.008 0.00803 Mass Element ( kg )
25.95128 0.2 0.01 0.0 11.54 255 2.518644969 0.75 0.01 0.01 11.95 63.08 63.05 63.05 0.014
-26 0.014 0.022 a
3:72351 0.5 0.01 0.0 11.54 264 2.487321569 1.75 0.01 0.01 13.50 85.26 85.17 85,17 0.057
-26 0.057 0.079 b
0,14041 0.5 0.02 0.0 11.54 270 2.466868584 5.24 0.05 0.05 14.62 103.81 103.43 103.43 0,069
-26 0.069 0.148 C
-1.69396 3,5 0.03 0.1 11.54 274.5 2.451748233 9.08 0.10 0.10 15.51 120.06 119.29 119.29 0.556
-25 0.556 0.703 d
10.35371 5.0 0.08 0.2 11.54 276 2.446749222 37.77 0.47 0.47 15.82 125.97 122.22 122.22 0.813
-24 0.813 1.516 e
0.17064 5.0 0.17 0.3 11.54 273 2.456767713 79.22 1.02 1.02 15.21 114.40 106.76 106.76 0.710
-24 0.710 2.227 I f
-4.17804 5.0 0.25 0.3 9.77 269,5 2.468560144 118.04 1.49 1.49 8.20 50,95 41.67 41.67 0.277
-23 0,277 2.504 5.0 0.33 0.4 8
264.5 2.485604209 124.89 1.68 1.68 4.33 21.57 13.21 13.21 0.088
-23 0,088 2,592 5.0 0.42 0.5 8
258 2.508116544 128.14 1.74 1.74 3.96 17.37 9.76 9.76 0.065
-23 0.065 2.657 15.0 0.50 0,8 8
249 2.539969238 130.61 1.78 1.78 3,50 12.79 6.26 6.28 0.125
-23 0.125 2.782 15.0 0.75 1.0 8
241 2.5689697 136.17 1.86 1.86 3.13 9.67 3.90 3.90 0,078
-23 0.078 2.860 30.0 1.00 1.5 8
238.5 2.578168641 141.23 1.92 1.92 3.02 8.85 3.23 3.23 0.129
-23 0.129 2.989 30.0 1.50 2.0 8
237 2.583719695 153.36 2.00 2.00 2.95 8.39 2.70 2.70 0.108
-23 0.108 3.097 120.0 2.00 4.0 8
233.5 2.596765584 166.05 2.08 2.08 2.81 7.40 1.93 1.93 0.308
-23 0.308 3.404 120.0 4.00 6.0 8
228 2.617534573 214.75 2.28 2.26 2.59 6.06 0.72 0.72 0.114
-22 0.114 3.519 120.0 6.00 8.0 8
220.5 2,646397224 260.28 2.36 2.36 2.31 4.59
-0.09 0.00 0.000
-22 0.000 3.519 120,0 8.00 10.0 8
213 2.675903489 302.37 2.36 2.36 2.06 3,46
-0.50 0.00 0.000
-22 0,000 3.519 120,0 10.00 12.0 8
208 2.695942606 338.87 2.36 2.36 1.91 2.85
-0.68 0.00 0.000
-22 0.000 3.519 120.0 12.00 14.0 8
203 2.716284123 369.12 2.36 369.12 1.76 2.34
-489.40 0.00 0.000
-22 0.000 3.519 120.0 14.00 16.0 8
196 2.736934937 394.66 2.36 394.66 1.62 1.92
-465.28 0.00 0.000
-22 0.000 3.519 240.0 16,00 20.0 8
193 2.757902156 416.44 2.36 416.44 1.50 1.57
-435.70 0,00 0.000
-22 0.000 3.519 240.0 20.00 24.0 8
187.5 2.781340297 452.99 2.36 452.99 1.37 1.25
-414.71 0.00 0.000
-22 0.000 3.519 720.0 24.00 36.0 8
180 2.813950943 483.82 2.36 483.82 1.20 0.92
-367.76 0.00 0.000
-22 0.000 3.519 720.0 36.00 48,0 8
170.5 2.85637209 555.36 2.36 555.36 1.02 0,61
-331.41 0,00 0.000
-22 0.000 3.519 1440.0 48.00 72.0 8
162 2.895426834 605.73 2.36 605.73 0.88 0,42
-289.21 0.00 0.000
-22 0.000 3.519 2860,0 72.00 120.0 8
158 2.914177473 676.22 2.36 676.22 0.81 0.35
-290.11 0.00 0.000
-22 0,000 3.519 3240,0 120.00 174.0 8
153 2.937960076 785.61 2.36 785.61 0.74 0.28
-294.25 0.00 0.000
-22 0.000 3.519 3960.0 174.00 240.0 8
143.85 2.982502651 875.72 2.36 875.72 0.62 0.18
-254.28 0.00 0.000
-22 0.000 3.519 7200.0 240.00 360.0 8
136.85 3.017501509 945.41 2.36 945.41 0.54 0.13
-224.75 0.00 0.000
-2 0.000 3.519 7200.0 360.00 480.0 8
132.15 3.04146531 1031.21 2.36 1031,21 0.50 0.10
-213.76 0.00 0.000
-22 0.000 3.519 7200 72(10!20 1
480.00 60.00 6000 720,0 8
8 126.25 121.1 3.072091753 3.099333643 1096.29 1144.23 2.36 2.36 1096.29 1144.23 0.44 0.40 408 0.06
-190.75
-170.38 0.00 0.00 0.000 0.000
-22
-22 0.000 0.000 3.519 3,519
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 307 of 492 Constants Mass Material (kg)
Value 0
Interval Duration (min) 0.2 Start of Interval (hrs) 0.00 End of Interval hrs) 0.01 Ave Interval H
11.54 Ave Temp (F) 239 1000lf (K) 2.576323586 Si All Mat 0
Si this Mat Only 0
Si (ppm) 0.00 K
156.65 k
31264.70 R
31264.70 Positive release rate (mg/kg-min 31264.70 interval pred release (kg) 0.000 Amount above start Mass 0
interval kg Si released 0.000 Integral kg Si released 0.00000 Mass Element (kg) 0 0.2 0.01 0.0 11.54 255 2.518644969 0.09 0.00 0.00 158.18 40417.13 40417.13 40417.13 0.000 0
0.000 0.000 a
b 1.17043 0.10511 0.5 0.5 0.01 0.02 0.0 0.0 11.54 11.54 264 270 2.487321569 2.466868584 0.22 0.68 0.00 0.00 0.00 0.00 159.02 159.57 46464.76 50893.91 46464.76 50893.91 46464.76 50893.91 0.000 0.000 0
0 0.000 0.000 0.000 0.000 o
d
-0.07315 7.41106 3.5 5.0 0.03 0,08 0.1 0.2 11.54 11.54 274.5 276 2.451748233 2.446749222 1.20 5.17 0.00 0.00 0.00 0,00 159.98 160.11 54437.52 55662,54 54437.52 55662.54 54437.52 55662.54 0.000 0.000 0
0 0.000 0.000 0.000 0.000 e
I f 0.17893
-1.93332 5.0 5.0 0.17 0.25 0.3 0.3 11.54 9.77 273 269.5 2.456767713 2.468560144 10.96 16.37 0.00 0.00 0.00 0.00 159.84 103.94 53234.61 24360.68 53234.61 24360,68 53234.61 24360.68 0.000 0.000 0
0 0.000 0.000 0.000 0.000 5.0 0.33 0.4 8
264.5 2.485604209 19.19 0.00 0.00 67.53 10890.10 10890.10 10890.10 0.000 0
0.000 0.000 5.0 0,42 0.5 8
258 2.508116544 20.77 0.00 0.00 67.27 9851.63 9851.63 9851.63 0.000 0
0.000 0.000 15.0 0.50 0.8 8
249 2.539969238 22.15 0.00 0.00 66.91 8549.22 8549.22 8549.22 0.000 0
0.000 0.000 15.0 0.75 1.0 8
241 2.5689697 25.58 0.00 0.00 66.59 7513.80 7513,80 7513.80 0.000 0
0.000 0.000 30.0 1.00 1.5 8
238.5 2.578168641 28.45 0.00 0.00 66.48 7212.32 7212.32 7212.32 0.000 0
0.000 0.000 30.0 1.50 2.0 8
237 2.583719695 33.84 0.00 0.00 66.42 7036.28 7036.28 7036.28 0.000 0
0.000 0.000 120.0 2.00 4.0 8
233.5 2.596765584 38.94 0,00 0.00 66.28 6639.28 6639.28 6639.28 0.000 0
0.000 0.000 120.0 4.00 6.0 8
228 2.617534573 57.42 0,00 0.00 66.04 6052.96 6052.96 6052.96 0.000 0
0.000 0.000 120.0 120.0 6.00 8.00 8.0 10.0 8
8 220.5 213 2.646397224 2.675903489 72.36 83.83 0.00 0.00 0.00 0.00 65.72 65.40 5323.13 4667.91 5323.13 4667.91 5323.13 4667.91 0.000 0.000 0
0 0.000 0.000 0.000 0.000 120.0 120.0 10.00 12.00 12.0 14.0 8
8 208 203 2.695942606 2.716284123 92.61 99.78 0,00 0.00 0.00 99.78 65.18 64.96 4269.53 3899.90 4269.53
-2091.08 4269.53 0.00 0.000 0.000 0
0 0.000 0.000 0.000 0.000 120.0 240.0 14.00 16.00 16.0 20.0 8
8 198 193 2.736934937 2.757902156 102.13 104.29 0.00 0.00 102.13 104.29 64.73 64.50 3557.37 3240.36
-2055.62
-1998.78 0.00 0.00 0.000 0.000 0
0 0.000 0.000 0.000 0.000 240.0 20.00 24.0 8
187.5 2.781340297 108,24 0.00 108.24 64.25 2919.30
-1999,11 0.00 0.000 0
0.000 0.000 720.0 24.00 36.0 8
180 2.813950943 111.79 0.00 111.79 63.90 2524.83
-1892.70 0.00 0.000 0
0.000 0.000 720.0 36.00 48.0 8
170.5 2.85637209 121.11 0,00 121.11 63.44 2090.35
-1900.10 0.00 0,000 0
0.000 0.000 1440.0 48.00 72.0 8
162 2.895426834 128.69 0.00 128.69 63.02 1756.76
-1830.36 0.00 0.000 0
0.000 0.000 2880.0 72.00 120.0 8
158 2.914177473 141.37 0.00 141.37 62.83 1616.08
-2020.43 0,00 0.000 0
0.000 0.000 3240.0 120.00 174.0 8
153 2.937960076 163.38 0.00 163.38 62.57 1453.73
-2342.01 0.00 0.000 0
0.000 0.000 3960,0 7200.0 174.00 240.00 240.0 360.0 8
8 143.85 136.85 2.982502651 3.017501509 183.30 202.13 0.00 0.00 183.30 202.13 62.11 61.74 1192.25 1020.24
-2326,52
-2319.89 0.00 0.00 0.000 0.000 0
0 0.000 0.000 0.000 0.000 7200.0 360.00 480.0 8
132.15 3.04146531 225.81 0.00 225.81 61.49 917.01
-2450.33 0.00 0.000 0
0.000 0.000 7200.0 480.00 600.0 8
126.25 3.072091753 225.81 0.00 225.81 61,18 800.14
-2153.22 0.00 0.000 0
0.000 0.00 0 7200.0 1
600.00 720.0 8
121.1 3.099333643 225.81 T
0.00 225.81 60.90 708.76
-1919.34 0.00 0.000 0
0.000 0.000
Entergy Attachment I Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 308 of 492 onstants alue Interval Duration min Startof Interval hrs End of Interval hrs Ave Interval H
Ave Temp F
000fT (K )
l All Mat Al this Mat Onl y I (ppm)
K k
R P osi tive release rate (m g/kg-interval pred release k
Amount above start Mass interval kg Al released Integral kg AI released Mass Material
( k g) 0 0.2 0. 00 0.01 11.54 239 2.576323586 0
0 0.00 66. 80 209.25 209.25 209.25 0.000 0
0.000 0.00000 Mass Element ( kg) 0 0,2 0. 01 0.0 11.54 255 2. 518644969 0.75 0.00 0.00 93.27 325. 22 325.22 325.22 0.000 0
0.000 0.000 a
5.529 0.5 0.01 0.0 11.54 264 2.487321569 1.75 0.00 0.00 111. 81 413. 22 413.22 413.22 0.000 0
0.000 0.000 b
0.2401 0. 5 0.02 0.0 11.54 270 2.466868584 5.24 0.00 0.00 125.86 483. 16 483. 16 483.16 0.000 0
0.000 0.000 c
d
-2.51326 8.48062 3. 5 5.0 0.03 0.08 0. 1 0.2 11.54 11.54 274.5 276 2.451748233 2.446749222 9.08 37.77 0.00
- 0. 00 0,00 0.00 137. 36 141.40 542.37 563. 50 542.37 563.50 542.37 563. 50 0.000 0.000 0
0 0.000 0.ODO 0.000 0.000 e
0.20749 5. 0 0.17 0.3 11.54 273 2.456767713 79.22 0. 00 0.00 133. 43 521.95 521.95 521.95 0. 000 0
0.000 0.000 I f
-3.32039 5. 0 0.25 0. 3 9,77 269.5 2.468560144 118.04 0. 00 0.00 46.84 204.75 204.75 204.75 0.000 0
0.000 0.000 5.0 0.33 0. 4 8
264.5 2.485604209 124.89
- 0. 00 0.00 15.95 77.16 77.16 77.16 0.000 3.600 0.000 5.0 0.42 0. 5 8
258 2. 508116544 128.14 0. 00 0.00 14.00 64. 96 64. 95 64.96 0.000 0
0. 000 0.000 15.0 0. 50 0.8 8
249 2.539969238 130.61 0.00 0.00 11. 65 50. 92 50. 92 50.92 0. 000 0
0.000 0.000 15.0 0.75 1.0 8
241 2.5689697 136. 17 0.00 0. 00 9,85 40.79 40.79 40.79 0,000 0
0.000 0.000 30.0 1. 00 1.5 8
238.5 2.578168641 141.23 0. 00 0.00 9. 34 38.02 38. 02 38.02 0.000 0
0.000 0.000 30.0 1.50 2. 0 8
237 2.583719695 153.36 0. 00 0.00 9. 04 36.44 36. 44 36.44 0.000 0
0.000 0.000 120.0 2.00 4.0 8
233.5 2.596765584 166.05 0, 00 0.00 8.38 32,98 32.98 32.98 0.000 0
0.000 0.000 120.0 4.00 6,0 8
228 2.617534573 214.75 0,00 0.00 7.43 28,14 28.14 28, 14 0.000 0
0. 000 0.000 120.0 6.00 8.0 8
220. 5 2.646397224 260.28 0.00 0.00 6.29 22,57 22.57 22.57 0.000 0
0.000 0.000 120.0 8.00 10. 0 8
213 2.675903489 302.37 0.00 0.00 5,30 18. 01 18. 01 18.01 0,000 0
0. 000 0,000 120.0 10.00 12.0 8
208 2. 695942606 338.87 0.00 0.00 4.72 15.45 15.45 15.45 0.000 0
0.000 0.000 120.0 12. 00 14. 0 8
203 2.716284123 369.12 0. 00 369.12 4.20 13.23
-1149. 59 0.00 0. 000 0
0. 000 0.000 120.0 14. 00 16.0 8
198,
2.736934937 394.66 0. 00 394. 66 3.73 11.29
- 1185.18 0.00 0.000 0
0.000 0.000 240.0 16. 00 20.0 8
193 2.757902156 416.44 0. 00 416.44 3.30 9.62
-1204. 64 0.00 0. 000 0
U00 0.000 240.0 20.00 24.0 8
187. 5 2.781340297 452.99 0.00 452.99 2.88 8.04
-1256.49 0.00 0.000 0
0.000 0.000 720.0 24.00 36.0 8
180 2. 813950943 483.82 0.00 483.82 2. 39 6.27
-1264. 89 0.00 0. 000 0
0. 000 0.000 720.0 36. 00 48.0 8
170. 5 2.85637209 555.36 0.00 555.36 1.87 4.53
-1343.97 0.00 0.000 0
0.000 0.000 1440.0 48. 00 72. 0 8
162 2.895426834 605.73 0.00 605.73 1.49 3. 36
-1364.47 0.00 0. 000 0
0.000 0.000 2880.0 72. 00 120.0 8
158 2.914177473 676.22 0. 00 676.22 1.34 2.91
-1471.80 0.00 0. 000 0
0. 000 0.000 3240.0 120. 00 174.0 8
153 2.937960076 785.61 0.00 785. 61 1.16 2.43
-1636.77 0.00 0. 000 0
0. 000 0.000 3960,0 174.00 240. 0 8
143.85 2. 982502651 875.72 0. 00 875.72 0.90 1.73
-1680.31 0.00 0.000 0
0.000 0.000 7200.0 240. 00 360. 0 136.85 3.017501509 945.41 0. 00 1 945.41 0.73 1.32
-1700. 23 000 0.000 0
0.000 0.000,
7200. 0 360. 00 480. 0 132.15 3. 04146531 1031.21 0.0 1031.21 0.64 1.10
-1774.02 0.00 0.000 0
0.000 0.000 7200. 0 480. 00 600.0 8
126.25 3. 072091753 1096.29 0.00 1096.29 0.54 0.87
-1781.87 0.00 0. 000 0
0. 000 0.000 7200.0 600.00 720.0 8
121. 1 3.099333643 1144. 23 0.00 1144.23 0.46 0.71
- 1768.14 0.00 0.000 0
0.000 0.000
Entergy Attachment I Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 309 of 492 onstants alue Interval Duration min Startof Interval hrs End of Interval (hrs)
Ave Interval H
Ave Temp F
000/T K) i All Mat Si this Mat Onl y i (ppm )
K k
R osi ve release rate (m g/kg-interval pred release k
Amount above start Mass interval kg Si released Integral kg Si released Mass Material (kg )
0 0.2 0.00 0.01 11.54 239 2.576323586 0
0 0.00 162.84 179.80 179.80 179.80 U00 0
0,000 0.000 Mass Element (kg )
0 0.2 0,01 0.0 11.54 255 2.518644969 0.09 0.00 0,00 239.08 248.14 248.14 248.14 0.000 0
0.000 0.000 a
7.51336 0.5 0.01 0.0 11.54 264 2.487321569 0.22 0.00 0.00 294.53 295.57 295.57 295.57 0.000 0
0.000 0.000 b
0.18619 0,5 0.02 0.0 11.54 270 2.466868584 0.68 0,00 0.00 337.50 331.33 331.33 331.33 0.000 0
0.000 0.000 c
I d e
-2.89181 7.17588 0.11502 3,5 5.0 5,0 0.03 0.08 0.17 0.1 0.2 0.3 11.54 11.54 11.54 274.5 276 273 2.451748233 2.446749222 2.456767713 1.20 5.17 10.96 0,00 0,00 0.00 0.00 0.00 0.00 373.25 385.89 360.98 360.53 370.73 350.56 360.53 370.73 350.56 360.53 370.73 350.56 0.000 0.000 0.000 0
0 0
0.000 0.000 0.000 0,000 0,000 0.000 I f
-2.42532 5.0 0.25 0.3 9.77 269.5 2.468560144 16.37 0.00 0,00 156.25 205.39 205.39 205.39 0,000 0
0.000 0.000 5.0 5.0 0.33 0.42 0.4 0.5 8
8 264.5 258 2.485604209 2.508116544 19.19 20.77 0.00 0.00 0,00 0.00 65.31 56.22 116.86 103.05 116.86 103.05 116.86 103.05 0,000 0.000 0
0 0.000 0.000 0.000 0.000 15.0 0.50 0.8 8
249 2.539969238 22.15 0.00 0.00 45.47 86.26 86.26 86.26 0.000 0
0.000 0.000 15.0 0.75 1.0 8
241 2.5689697 25.58 0.00 0.00 37.49 73.36 73.36 73.36 0.000 0
0.000 0.000 30.0 1.00 1.5 8
238.5 2.578168641 28.45 0.00 0.00 35.26 69.69 69.69 69.69 0.ODD 0
0.000 0.000 30.0 1.50 2.0 a
237 2.583719695 33.84 0.00 0.00 33.98 67.56 67.56 67.56 0.00 2
0.000 0.000 120.0 2.00 4.0 8
233.5 2.596765584 38.94 0,00 0.00 31.15 62.81 62.81 62.81 0.00 0
1 0.000 0.000 120.0 4,00 6.0 a
228 2.617534573 57.42 0.00 0.00 27.13 55.93 55.93 55.93 0.000 0
0,000 0.000 120.0 6.00 8.0 8
220.5 2.646397224 72.36 0.00 0,00 22.39 47.61 47.61 47.61 0.000 0
0.000 0.000 120.0 8.00 10,0 8
213 2.675903489 83.83 0.00 0.00 18.39 40.38 40.36 40.38 0.000 0
0.000 0.000 120.0 10.00 12.0 8
208 2.695942606 92.61 0.00 0.00 16.10 36.10 36.10 36.10 0.000 0
0.000 0.000 120.0 12.00 14.0 8
203 2.716284123 99.78 0.00 99.78 14.06 32.22
-196.51 0.00 0.000 0
0.000 0.000 120.0 14.00 16.0 8
198 2.736934937 102.13 0.00 102.13 12.25 28.71
-210.66 0.00 0.000 0
0.000 0.000 240.0 16.00 20,0 8
193 2.757902156 104.29 0.00 104.29 10.65 25.54
-224.45 0.00 0.000 0
0,000 0.000 240.0 20.00 24.0 8
187.5 2.781340297 108.24 0.00 108.24 9.12 22.41
-243.68 0.00 0.00D D
0.000 0.000 720.0 24.00 36.0 8
180 2.813950943 111.79 0.00 111.79 7.34 18.66
-265.94 0.00 0.000 0
0.000 0.000 720.0 1440.0 36.00 48.00 48,0 72.0 8
8 170.5 162 2.85637209 2.895426834 121.11 128.69 0.00 0.00 121.11 128.69 5.53 4.26 14.74 11.85
-307.96
-345.74 0.00 0.00 0.000 0.000 0
0 0.000 0.000 0.000 0.000 2880.0 72.00 120,0 8
158 2.914177473 141.37 0.00 141.37 3.76 10.67
-390.15 0.00 0.000 0
0.000 0.000 3240.0 120.00 174.0 8
153 2.937960076 163.38 0.00 163.38 3.21 9.34
-465.88 0.00 0.000 0
0.000 0.000 3960.0 174.00 240.0 8
143.85 2.982502651 183.30 0.00 183.30 2.39 7.29
-551.99 0.00 0.000 0
0.000 0.000 7200.0 240.00 36.0 136.85 3.017501509 20213 0.00 202.13 1.89 5.99
-634.38 0.00 0.000 0
O.OOD 0.000 7200.0 360.00 480.0 132.15 3.04146531 225.81 0.00 225.81 1.61 5.24
-728.79 0.00 0.000 0
0.000 0.000 7200.0 480.00 600.0 8
126.25 3.072091753 225,81 0.00 225.81 1.32 4,42
-744.16 0.00 0.000 0
0.000 0.000 7200.0 600.00 720,0 8
121,1 3.099333643 225.81 0.00 22 5.81 1.10 3.79
-777.31 0.00 0.000 0
0.000 0.000
Entergy Attachment I Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 310 of 492 onstants alue Interval Duration min Startof Interval hrs End of Interval hrs Ave Interval H
Ave Temp F
000lr K' a All Mat Ca this Mat Onl a (ppm )
K k
R osi ve release rate (m g /k g-interval pred release k
Amount above start Mass interval kg Ca released Integral kg Ca released Mass Material (kg )
Mass Element (k 0
0 0.2 0.2 0.00 0.01 0.01 0.0 11.54 11.54 239 255 2.576323586 2.518644969 0
0.01 0
0.00 0.00 0.00 36.49 40.72 47.21 50.61 47.21 50.61 47.21 50,61 0.000 0.000 0
0 0.000 0.000 0.0000 0.000 a
b 2.30159 0.12022 0.5 0.5 0.01 0.02 0.0 0.0 11.54 11.54 264 270 2.487321569 2.466868584 0.01 0.03 0.00 0.00 0.00 0.00 4122 44,93 52.57 53.88 52.57 53.88 52,57 53.88 0.000 0.000 0
0 0.000 0.000 0.000 0.000 dC
-0.82549 1.98549 3.5 5.0 0.03 0.08 0.1 0.2 11.54 11.54 274.5 276 2.451748233 2.446749222 0.05 0.20 0.00 0.00 0.00 0.00 46.24 46.68 54.87 55.21 54.87 55.21 54.87 55.21 0.000 0.000 0
0 0.000 0.000 0.000 0.000 e
0.09009 5.0 0.17 0.3 11.54 273 2.456767713 0.41 0.00 0.00 45.80 54.54 54.54 54.54 0.000 0
0.000 0.000 I f
-0.52443 5.0 0.25 0.3 9.77 269.5 2.468560144 0.61 0.00 0.00 27.44 37.25 37.25 37.25 0.000 0
0.000 0.000 5.0 0.33 0.4 8
264.5 2.485604209 0.80 0.00 0.00 16.27 25.27 25.27 25,27 0.000 0
0.000 0.000 5.0 0.42 0.5 8
258 2.508116544 0.99 0.00 0.00 15.59 24.60 24.60 24.60 0.000 0
0.000 0.000 15.0 0.50 0.8 8
249 2.539969238 1.17 0.00 0.00 14.68 23.67 23.67 23.67 0.000 0
0,000 0.000 15.0 0.75 1.0 8
241 2.5689697 1.70 0.00 0.00 13.89 22.85 22.85 22.85 0.000 0.000 0,000 30.0 1.00 1.5 8
236.5 2.578168641 2.21 0.00 0.00 13.65 22.60 22.60 22.60 0.000 0
0.000 0.000 30.0 1.50 2.0 8
237 2.583719695 3.20 0.00 0.00 13.51 22.45 22.45 22.45 0.000 0
0.000 0.000 120.0 2.00 4.0 8
233,5 2.596765584 4.15 0.00 0.00 13.17 22.10 22.10 22.10 0.000 0
0.000 0.000 120.0 4.00 6.0 8
228 2.617534573 7.83 0.00 0.00 12.66 21.55 21.55 21.55 0.000 0
0.000 0.000 120.0 6.00 8.0 8
220.5 2.646397224 11.04 0.00 0.00 11,99 20.81 20.81 20.81 0.000 0
0.000 0.000 120.0 8.00 10.0 8
213 2.675903489 13.92 0.00 0.00 11.33 20.09 20.09 20.09 0.000 0
0.000 0.000 120.0 10.00 12.0 8
208 2.695942606 16.57 0.00 0.00 10.91 19.61 19.61 19.61 0,000 0
0.000 0.000 120.0 12.00 14.0 8
203 2.716284123 19.05 0.00 19.05 10.50 19.13
-15.59 0.00
.000 0
0.000 0.000 120.0 14.00 16.0 8
198 2.736934937 20.19 0.00 20.19 10.09 18.66
-18.66 0.00 0.000 0
0.000 0.000 240.0 16.00 20.0 8
193 2.757902156 21.43 0.00 21.43 9.70 18.19
-22.00 0,00 0.000 0
0.000 0.000 240.0 20.00 24.0 8
187.5 2.781340297 24.15 0.00 24.15 9.28 17.68
-28.36 0.00 0.000 0
0.000 0.000 720.0 24.00 36.0 8
180 2.813950943 27.04 0.00 27.04 8.72 17.00
-35.73 0.00 0.000 0.000 0.000 720.0 36.00 48.0 8
170.5 2.85637209 36.98 0.00 36.98 8.04 16.15
-58.11 0.00 0.000 0
0.000 0.000 1440.0 48.00 72.0 8
162 2.895426834 47.01 0.00 47.01 7.47 15.41
-81.59 0.00 0.000 0
0.000 0.000 2880.0 72.00 120.0 8
158 2.914177473 68.08 0.00 68.08 7.21 15.06
-127.25 0.00 0.000 0
0.000 0.000 3240.0 3960.0 120.00 174.00 174.0 240.0 8
8 153 143,85 2.937960076 2.982502651 90.46 95.74 0.00 0.00 90.46 95.74 6.89 6.33 14.64 13.87
-177.59
-195.96 0.00 0,00 0.000 0.000 0
0 0.000 0.000 0.000 0.000 7200.0 240.00 360.0 8
136.85 3.017501509 129.07 0.00 129.07 5.92 13.30
-276.54 0.00 0.000 0
0.000 0.000 7200.0 360.00 480.0 8
132.15 3.04146531 143.24 0.00 143.24 5.66 12.92
-314.12 0.00
.000 0.000 0.000 7200.0 480.00 600.0 8
126.25 3.072091753 160,01 0.00 160.01 5.34 12,45
-360.70 0.00 0.000 0
0.000 0.000 7200.0 600.00 1 720.0 8
121.1 1 3.099333643 192.35 0.00 192.35 5.07 12.05
-445.08 0.00 0,000 0
0.000 0.000
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 1 2 1 22-00 5 Page 311 of 492 Constants Mass Material (kg)
Value 0
Interval Duration (min) 0.2 Start of Interval (hrs) 0.00 End of Interval hrs 0.01 Ave Interval H
11.54 Ave Temp (F) 239 1000IT K) 2.576323586 Al All Mat 0
Al this Mat Only 0
AI p m 0.00 K
19.69 k
33.66 R
33,66 Positive release rate (mg/kg-min) 33.66 interval pred release (kg) 0,000 Amount above start Mass 0
interval kg Al released 0.000 Integral kg AI released 0.000 Mass Element (kg) 0 0,2 0.01 0.0 11.54 255 2.518644969 0.75 0.00 0.00 19.15 47,36 47.36 47.36 0.000 0
0,000 0,000 a
-1.062762025 0.5 0.01 0.0 11.54 264 2.487321569 1.75 0.00 0.00 16.87 57.02 57.02 57.02 0.000 0
0.000 0.000 b
C 0.157710607 0.208439712 0.5 3.5 0.02 0.03 0.0 0.1 11.54 11.54 270 274.5 2.466868584 2.451748233 5.24 9.08 0.00 0.00 0.00 0.00 18.68 18.55 64.37 70.40 64.37 70.40 64.37 70.40 0.000 0.000 0
0 0.000 0.000 0.000 0.000 d
6.629 5.0 0,08 0.2 11.54 276 2.446749222 37.77 0.00 0.00 18.50 72.51 72.51 72.51 0.000 0
0.000 0.000 e
0.13222 5.0 0.17 0.3 11.54 273 2.456767713 79.22 0.00 0.00 18.59 68.33 68.33 68.33 0.000 0
0.000 0.000 f
-2.57256 5.0 0.25 0.3 9.77 269.5 2.468560144 118.04 0.00 0.00 9,83 37.18 3718 37.18 0.000 0
0.000 0.000 5.0 0.33 0.4 8
264.5 2.485604209 124.89 0.00 0.00 5.21 19.61 19.61 19.61 0.000 0
0.000 0.000 5.0 15.0 0.42 0.50 0.5 0.8 8
8 258 249 2.508116544 2.539969238 128.14 130.61 0.00 0.00 0.00 0.00 5.27 5.35 17.16 14.21 17.16 14.21 17.16 14.21 0.000 0.000 0
0 0.000 0.000 0.000 0.000 15.0 0.75 1.0 8
241 2.5689697 136.17 0.00 0.00 5,42 11.97 11.97 11.97 0.000 0
0.000 0.000 30.0 30.0 1.00 1.50 1.5 2.0 8
8 238.5 237 2.578168641 2.583719695 141.23 153.36 0.00 0.00 0.00 0.00 5.45 5.46 11.33 10.96 11.33 10.96 11.33 10.96 0.000 0.000 0
0 0.000 0.000 0.000 0.000 120.0 2.00 4.0 8
233.5 2.596765584 166.05 0.00 0.00 5.50 10.15 10.15 10.15 0.000 0
0.000 0.000 120.0 4.00 6.0 8
228 2.617534573 214.75 0.00 0.00 5.55 8.97 8.97 8.97 0.000 0
0.000 0.000 120.0 6.00 8.0 8
220.5 2.646397224 260.28 0.00 0.00 5.63 7.56 7.56 7.56 0.000 0
0.000 0.000 120.0 8.00 10.0 8
213 2.675903489 302.37 0.00 0.00 5.71 6.35 6.35 6.35 0.000 0
0.000 0.000 120.0 10.00 12.0 8
208 2.695942606 338.87 0.00 0.00 5,77 5.64 5.64 5.64 0,000 0
0.006 0.000 120.0 12.00 14.0 8
203 2.716284123 369.12 0.00 369.12 5.82 5.00
-311.97 0.00 0.000 0
0,000 0.000 120.0 14.00 16.0 8
198 2.736934937 394.66 0.00 394.66 5.88 4.42
-292.50 0.00 0.000 0
0,000 0.000 240.0 240,0 16.00 20.00 20.0 24.0 8
8 193 187.5 2.757902156 2.781340297 416.44 452,99 0.00 0.00 416.44 452.99 5.94 6.01 3.91 3.40
-270.04
-253,06 0.00 0.00 0.000 0.000 0
0 0.000 0.000 0.000 0.000 720.0 720.0 24.00 36,00 36.0 48.0 8
8 180 170.5 2.813950943 2.85637209 483.82 555.36 0.00 0.00 483.82 555.36 6.10 6,23 2.80 2.18
-219.49
-192.26 0.00 0.00 0.000 0.000 0
0 0.000 0.000 0.000 0.000 1440.0 2880.0 48.00 72.00 72.0 120.0 8
8 162 158 2.895426834 2.914177473 605.73 676.22 0.00 0,00 605.73 676.22 6.35 6.40 1.73 1.55
-163.44
-161.98 0.00 0.00 0.000 0.000 0
0 0.000 0.000 0.000 0,000 3240.0 120.00 174.0 8
153 2.937960076 785.61 0.00 785.61 6.48 1.34
-161.80 0.00 0.000 0
0.000 0.000 3960.0 174.00 240.0 8
143.85 2.982502651 875.72 0.00 875,72 6.62 1.03
-135.70 0.00 0.000 0
0,000 0.000 7200.0 240.00 360.0 8
136.85 3.017501509 945.41 0.0 945.41 6.73 0.84
-117.13 0.00 0.000 0
0.000 0.000 7200.0 360.00 480.0 8
132.15 3.04146531 1031.21 0.00 1031.21 6.81 0.73
-109.65 0.00 0,000 0
0.000 0.000 7200.0 7200.0 480.00 600.00 600.0 720.0 8
8 126.25 121.1 3.072091753 3.099333643 1096.29 1144.23 0.00 0.00 1096.29 1144.23 6.91 7.00 0.61 0.52
-95.4
-84.03 0.00 0.00 0.000 0.000 0
0 0.000 0.000 0.000 0.000
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 312 of 492 onstants Mass Material (kg) alue 0
Interval Duration min 0.2 Startof Interval (hrs) 0.00 End of Interval (hrs 0.01 Ave Interval pH 11.54 Ave Temp
( F) 239 000li (K) 2.576323586 i All Mat 0
Si this Mat Only 0
i (ppm) 0.00 K
72.01 k
244.03 R
244.03 osi ve release rate (mg/kg-244.03 interval pred release (kg) 0.000 Amount above start Mass
-0 interval kg Si released 0.000 Integral kg Si released 0.0000 Mass Element (kg) 0 0.2 0.01 0.0 11.54 255 2.518644969 0.09 0.00 0.00 84.90 325.72 325.72 325.72 0.000 0
0.000 0.000 a
3.262764542 0.5 0.01 0.0 11.54 264 2.487321569 0.22 0.00 0.00 92.84 381.02 381.02 381.02 0.000 0
0.000 0.000 6
C 0,155049444
-1.240000065 0.5 3.5 0.02 0.03 0.0 0.1 11.54 11.54 270 274.5 2.466868584 2.451748233 0.68 1.20 0.00 0.00 0.00 0.00 98.43 102.77 422.10 455.30 422.10 455.30 422.10 455.30 0.000 0.000 0
0 0.000 0.000 0.000 0.000 d
6.07665 5.0 0.08 0.2 11.54 276 2.446749222 5,17 0.00 0,00 104.25 466,83 466.83 466.83 0.000 0
0.000 0.000 e
0.16569 5.0 0.17 0.3 11.54 273 2.456767713 10.96 0.00 0.00 101.31 444.00 444.00 444.00 0.000 0
0.000 0.000 I f
-2.17413 5.0 0.25 0.3 9.77 269.5 2.468560144 16.37 0,00 0.00 52.07 213.04 213.04 213.04 0.000 0
0.000 0.000 5.0 0.33 0.4 8
264.5 2.485604209 19.19 0.00 0.00 26.36 99.57 99.57 99.57 0.000 0
0.000 0.000 5,0 0.42 0.5 8
258 2.508116544 20.77 0.00 0.00 24.72 88.96 88.96 88.96 0.000 0
0.000 0.000 15.0 0.50 0.8 8
249 2.539969238 22.15 0.00 0.00 22.57 75.85 75,85 75.85 0.000 0
0.000 0.000 15.0 0.75 1,0 8
241 2.5689697 25.58 0.00 0.00 20.78 65.60 65.60 65.60 0.000 0
0.000 0.000 30.0 1.00 1.5 8
238.5 2.578168641 28.45 0.00 0.00 20.24 62.65 62.65 62.65 0.000 0
0.000 0.000 30.0 1.50 2.0 8
237 2.583719695 33.84 0.00 0.00 19.92 60.93 60.93 60.93 0.000 0
0.000 0.000 120.0 2.00 4.0 8
233.5 2.596765584 38.94 0.00 0.00 19.19 57.08 57.08 57.08 0.000 0
0.000 0.000 120.0 120.0 4.00 6.00 6.0 8.0 8
8 228 220.5 2.617534573 2.646397224 57.42 72.36 0.00 0.00 0.00 0.00 18.09 16.66 51.44 44.52 51.44 44.52 51.44 44.52 0.000 0.000 0
0 0.000 0.000 0.000 0.000 120.0 120.0 8.00 10.00 10.0 12.0 8
8 213 208 2.675903489 2.695942606 83.83 92.61 0.00 0,00 0.00 0.00 15.31 14.46 38.41 34.74 38.41 34.74 38.41 34.74 0.000 0,000 0
0 0.000 0.000 0.000 0.000 120.0 12.00 14.0 8
203 2.716284123 99.78 0.00 99.78 13.64 31.38
-198.08 0.00 0.000 0
0.000 0.000 120.0 14.00 16.0 8
198 2.736934937 102.13 0.00 102.13 12.86 28.30
-196.36 0.00 0.000 0
0.000 0,000 240.0 16.00 20.0 8
193 2.757902156 104.29 0.00 104.29 12.12 25.48
-193.61 0.00 0.000 0
0.000 0.000 240.0 20.00 24.0 8
187.5 2.781340297 108.24 0.00 108.24 11.33 22.66
-193.75 0.00 0.000 0
0.000 0.000 720.0 24.00 36.0 8
180 2.813950943 111.79 0.00 111.79 10.32 19.24
-189.12 0.00 0.000 0
0.000 0.000 720,0 1440.0 36.00 48.00 48.0 72.0 8
8 170.5 162 2.85637209 2.895426834 121.11 128.69 0.00 0.00 121.11 128.69 9.15 8.18 15.56 12.80
-190.48
-188.50 0.00 0.00 0.000 0.000 0
0 0.000 0.000 0.000 0.000 2880.0 3240.0 72.00 120.00 120,0 174.0 8
8 158 153 2.914177473 2.937960076 141.37 163.38 0.00 0.00 141,37 163.38 7.75 7.25 11.65 10.34
-200.75
-222.89 0.00 0.00 0.000 0.000 0
0 0.000 0.000 0.000 0.000 3960.0 7200.0 174.00 240.00 240.0 360.0 8
8 143,85 136.85 2.982502651 3.017501509 183.30 202.13 0.00 0.00 183.30 202.13 6.38 5.77 8.28 6.95
-229.48
-236.22 0.00 0.00 0.000 0.000 0
0 0.000 0.000 0.000 0.000 7200,0 7200.0 360.00 480.00 480.0 600.0 8
8 132.15 126.25 3.04146531 3.072091753 225.81 225.81 0.00 0.00 225.81 225.81 5.39 4.94 6.16 5.28
-251.8
-236.27 0.00 0.00 0.000 0.000 0
0 0.000 0.000 0.000 0.000 7200.0 600.00 720.0 8
121.1 3.099333643 225.81 0.00 225.81 4.57 4.61
-223.20 0.00 0.000 0
0.000 0.000
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 313 of 492 Constants Mass Material (kg)
Value 0
Interval Duration (min) 0.2 Start of Interval (hrs) 0.00 End of Interval (hrs) 0.01 Ave Interval pH 11.54 Ave Temp (F) 239 1000/T K-')
2.576323586 Si All Mat 0
Si this Mat Only 0
Si (ppm) 0.00 K
17.34 k
12770.98 R
12770.98 Positive release rate (mg/kg-min) 12770.98 interval pred release (kg )
0.000 Amount above start Mass 0
interval kg Si released
.000 Integral kg Si released 0.000 Mass Element (kg) 0 0.2 0.01 0.0 11.54 255 2.518644969 0.09 0.00 0.00 18.27 28557.66 28557.66 28557.66 0.000 0
0.000 0.000 a
b 0.974998166 0.111219937 0.5 0.5 0.01 0.02 0.0 0.0 11.54 11.54 264 270 2.487321569 2.466868584 0.22 0.68 0.00 0.00 0.00 0.00 18.80 19.16 44210.36 58810.79 44210.36 58610.79 44210.36 58810.79 0.000 0.000 0
0 0.000 0.000 0.000 0.000 o
d q
-0.395709671 15.69692 3.5 5.0 0.03 0.08 0.1 0.2 11.54 11.54 274.5 276 2.451748233 2.446749222 1.20 5.17 0.00 0.00 0.00 0.00 19.42 19,51 72623.54 77869.70 72623.54 77869.70 72623.54 77869.70 0.000 0,000 0
0 0.000 0.000 0.000 0.000 e
i f
-6.05941 5.0 5.0 0.17 0.25 0.3 0.3 11.54 9.77 273 269,5 2.456767713 2.468560144 10.96 16.37 0.00 0.00 0.00 0,00 19.33 12.16 67711.49 13885.92 67711.49 13885.92 67711.49 13885,92 0.000 0.000 0
0 0.000 0,000 0.000 0.000 5.0 0.33 0.4 8
264.5 2.485604209 19.19 0.00 0.00 7.61 2646.46 2646.46 2646.46 0.000 0
0.000 0.000 5.0 0.42 0,5 8
258 2.508116544 20.77 0,00 0.00 7.45 1933.10 1933.10 1933.10 0.000 0
0.000 0.000 15.0 0.50 0.8 8
249 2.539969238 22.15 0.00 0.00 7.24 1239.50 1239.50 1239.50 0.000 0
0.000 0.000 15.0 0.75 1.0 8
241 2.5689697 25.58 0.00 0.00 7.05 827.03 827.03 827.03 0.000 0
0.000 0.000 30.0 1.00 1.5 8
238.5 2.578168641 28.45 0.00 0.00 6.99 727.41 727.41 727.41 0.000 0
0.000 0.000 30.0 1.50 2.0 8
237 2.583719695 33.84 0.011 0.00 6.96 673.20 673.20 673.20 0.000 0
0.000 0.000 120.0 2.00 4.0 6
233.5 2.596765584 38.94 0.00 0.00 6,87 561.17 561,17 561.17 0.000 b
0.000 0.000 120.0 4.00 6.0 8
228 2.617534573 57.42 0.00 0.00 6.74 4211.110 420.00 420.00 0.000 0
0.000 0.000 120.0 6.00 8.0 8
220.5 2.646397224 72.36 0,00 0.00 6.57 280,77 280.77 280,77 0.000 0
0,000 0.000 120.0 8.00 10.0 8
213 2.675903489 83.83 0.00 0.00 6.40 186,02 186.02 186.02 0.000 0
0.000 0.000 120.0 10.00 12.0 8
208 2.695942606 92.61 0.00 0.00 6.28 140.65 140,65 140.65 0.000 0
0.000 0.000 120.0 12.00 14.0 8
203 2.716284123 99.78 0.00 99.78 6.16 105.90
-1606.22 0.00 0.000 0
0.000 0.000 120.0 14.00 16.0 8
198 2.736934937 102.13 0,00 102.13 6.05 79.39
-1260.88 0.00 0.000 0
0.000 0.000 240.0 16.00 20.0 8
193 2.757902156 104.29 0.00 104.29 5.94 59.25
-961.88 0.00 0.000 0
0.000 0.000 240.0 20,00 24,0 8
187,5 2.781340297 108.24 0.00 108.24 5.81 42.72
-753.30 0.00 0.000 0
0.000 0.000 720.0 24.00 36.0 6
180 2.813950943 111.79 0.00 111.79 5.64 27.11
-516.23 0.00 0.000 0
0.000 0.000 720.0 36.00 48.0 8
170.5 2.85637209 121.11 0.00 121.11 5.43 15.00
-319.76 0.00 0.000 0
0.000 0.000 1440.0 46.00 72.0 6
162 2.895426834 128.69 0.00 128.69 5.24 8.70
-205.06 0.00 0.000 0
0.000 0.000 2880.0 72.00 120.0 8
158 2.914177473 141.37 0.00 141.37 5.15 6.70
-177.18 0.00 0.000 0
0.000 0.000 3240.0 120,00 174.0 8
153 2.937960076 163.38 0.00 163.38 5.04 4.80
-151.04 0,00 0.000 0
0,000 0.000 3960.0 174.00 240.0 8
143.85 2.982502651 183.30 0.00 183.30 4.84 2.58
-95.22 0.00 0.000 0
0.000 0.000 7200.0 240.00 360.0 8
136.85 3.017501509 202.13 0.00 202.13 4.68 1.58
-66,75 0.00 0.000 0
0.000 0.000 7200 360.00 480.0 8
132.5
.04146531 225.81 0.00 225.81 4.58 1.13
-54.71 0.00 0.000 0
0.000 0.000 M
480.00 600.0 8
126.25 3.072091753 225.81 O,DO 225.61 4.46 0.74
-36.72 0.00 0.000 0
0,000 0,000 600.00 720.0 8
121.1 1
3.099333643 225.81 11.110 225.81 4.35 0.51
-25.75 0.00 0.000 0
0.000 0.000
Entergy Attachment I Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 314 of 492 Interval Duration min Startof Interval hrs End of Interval hrs Average Interval H
ve. T (F) 1000 /T Kelvin 1
pHa square d
pHa /
(1000/
log p rediction corrosion rate (mg/m2-min interval mg Al released interval kg Al released Integral kg Al released mass available Inte g ral k Al odel term oeff 0.2 0.2 0.00 0.01 0,0056 0.01 11.54 11.54 239 255 2.576323586 2.518644969 133.17 133.17 4.48 4.58 3.27476089 3.41947152 1882.6123 2627.0692 931395 1299704 0.931 1.2997 1
2 0.9314 2.231 Intercept pHa 14.69039 0
0.5 0.5 0.01 0.02 0.02 0.03 11.54 11.54 264 270 2.487321569 2.466868584 133.17 133.17 4.64 4.68 3.49566461 3.54446584 3130.867 3503.2073 4646853 5199483 4.647 5.199 7
12 6.878 12.077 1000/7 K-1 pHa sq uared
-4.64537 0.044554 3.5 0.03 0.08 11.54 274.5 2.451748233 133.17 4.71 3.58004763 3802,3109 39503901 39,504 52 51.581 pHa/(1000/T)
-1.20131 5.0 0.08 0.17 11.54 276 2.446749222 133.17 4.72 3.59171727 3905.8654 57971106 57.971 110 109.552 5.0 0.17 0.25 11.54 273 2.456767713 133.17 4.70 3.5682829 3700.6916 54925905 54.926 164 164.478 5.0 0.25 0.33 9.77 269.5 2.468560144 95.45 3.96 2.72130634 526.38843 7812691 7.813 172 172.291 5.0 0.33 0.42 a
264.5 2.485604209 64,00 3.22 2.12883904 134.53617 1996794 1.997 174 174.288 5.0 0.42 0.50 8
258 2.508116544 64,00 3.19 2.05896551 114.5422 1700043 1.700 176 175.988 15.0 0.50 0.75 8
249 2.539969238 64.00 3.15 1.95905046 91.0019 4051968 4.052 180 180.040 15.0 0.75 1.00 8
241 2.5689697 64.00 3.11 1.86704593 73.628496 3278397 3.278 183 183.318 30.0 1.00 1.50 6
238.5 2.578168641 64.00 3.10 1,83766136 68.811554 6127833 6.128 189 189.446 30.0 1.50 2.00 6
237 2.583719695 64.00 3.10 1.81988342 66.051611 5882054 5.882 195 195.328 120,0 2.00 4.00 8
233.5 2.596765584 64.00 3.08 1.77796752 59.974622 21363533 21.364 217 216.692 120.0 4.00 6.00 8
228 2.617534573 64.00 3.06 1.71085331 51.387005 18304542 18.305 235 234.996 120.0 6.00 8.00 8
220.5 2.646397224 64.00 3.02 1.61681938 41.382753 14740932 14.741 250 249.737 120.0 8.00 10.00 8
213 2.675903489 64.00 2.99 1.51979563 33.097533 11789658 11.790 262 261.527 120.0 10.00 12.00 8
208 2.695942606 64.00 2.97 1.45340236 28.405495 10118309 10.118 272 271.645 120.0 12.00 14.00 8
203 2.716284123 64.00 2.95 1.38560433 24.299892 8655853 8.656 280 280.301 120.0 14.00 16.00 8
198 2.736934937 64.00 2,92 1.31636951 20.719034 7380318 7,380 288 287.681 240.0 16.00 20.00 8
193 2.757902156 64.00 2.90 1.24566487 17.606169 12542971 12.543 300 300.224 240.0 20.00 24.00 8
187.5 2.781340297 64.00 2.88 1.16615147 14.660591 10444485 10,444 311 310.669 720.0 24.00 36.00 6
180 2.813950943 64.00 2.84 1.05470673 11.342446 24241726 24.242 335 334.910 720.0 36.00 48.00 8
170,5 2.85637209 64.00 2.80 0.90836693 8.0977978 17307078 17.307 352 352.218 1440,0 48.00 72.00 8
162 2.895426834 64.00 2.76 0.77232615 5.9200606 25305386 25,305 378 377.523 2880.0 72.00 120,00 6
158 2.914177473 64.00 2.75 0.70657918 5.0883758 43500674 43.501 421 421.024-3240.0 120.00 174.00 8
153 2.937960076 64.00 2.72 0.62279605 4.1956191 40352029 40.352 461 461.376 3960.0 174.00 240.00 8
143.85 2.982502651
.00 111
.68 0.46473274 2.9156322 34273009 34.273 496 495,649 7200.0 240.00 360.00 8
136.85 3.017501509 64.00 2.65 0.3395243 2.1853666 46706908 46.707 542 542.356 7200.0 360.00 480.00 6
132.15 3.04146531 64.00 2.63 0.25329769 1.7918337 296096 38.296 581 580.652 7200.0 480,00 600,00 8
126.25 3.072091753 64.00 2.60 0.14252766 1.3884417 29674572 29,675 610 610.326 7200,0 600.00 720.00 8
121.1 3.099333643 64.00 2.58 0.04347574 1.1052887 23622864 23.62 634 633.949
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 315 of 492 Elapsed Time (min) 0.1666667 0
1 1
2 90 120 240 360 480 600 720 840 960 1200 1440 2160 2880 4320 7200 10440 14400 21600 28800 36000 Interval Duration (min)
Start of Interval hrs End of Interval (hrs)
Average Interval pH Average Temperature (F) 100011 (K) pHs square d
pHa/(1 00011) log prediction corrosion rate (mg/m2-m1n) interval mg Al released interval Kg Al released Integral kg Al released mass available Integral kg Al Model term Value 0.167 0.00 0,01 5.1 280.5 2.431873759 26.01 2.10 2.032967759 107.8866627 181659 0
0.182 0.1817 Intercept 14.69039 0.167 0.01 0.01 5.1 280 2.43351765 26.01 2.10 2.027033138 106.422422 179193 0.179 0.361 0.361 pHs 0
0.500 0.01 0.02 5.1 277.5 2.441770555 26.01 2.09 1.997204648 99.35841343 501897 0.502 0,863 0.863 1000/1 (K-1)
-4.645366 0.500 0.02 0.03 5.1 274 2.453419112 26.01 2.08 1.955005821 90.15832222 455424 0.455 1.318 1.318 pHa squared 0.044554 3.5 0.03 0,08 5.1 268.5 2.471950231 26.01 2.06 1.887642394 77.20446081 2729921 2.730 4.048 4.048 pHa/(1000/T)
-1.20131 5.0 0.08 0.17 5.1 260 2.501146359 26.01 2.04 1.780947231 60.38752508 3050401 3.050 7.098 7.098 5.0 0.17 0.25 5.1 250 2.536390153 26.01 2.01 1.651264005 44,79855492 2262943 2.263 9.361 9.361 5.0 0.25 0.33 6.55 242.5 2.563481778 42.90 2.56 1.624061556 42.07862659 2125549 2.126 11.487 11.487 5.0 0.33 0.42 8
230 2.609943886 64.00 3.07 1.735436522 54.37966427 2746921 2.747 14.234 14.234 5.0 0.42 0.50 8
217.5 2.658121299 64.00 3.01 1.578374222 37.87688205 1913304 1.913 16.147 16.147 15,0 0.50 0.75 8
206.5 2.702013 64.00 2.96 1.433211892 27.11514253 4109063 4.109 20.256 20,256 15.0 0.75 1.00 8
207 2.6999865 64.00 2.96 1.439956147 27.53950611 4173372 4.173 24.430 24.430 30.0 1.00 1.50 8
218.5 2.654201749 64.00 3.01 1.591242813 39.01600634 11825070 11.825 36,255 36.255 30.0 1.50 2.00 8
221.5 2.642512148 64.00 3.03 1.629527827 42.61159856 12914831 12.915 49.170 49.170 120.0 2.00 4.00 8
221 2.644453259 64.00 3.03 1.623180232 41.99332201 50909768 50.910 100.079 100.079 120.0 4.00 6.00 B
220 2.648344049 64.00 3.02 1.610445242 40.77981409 49438596 49.439 149,518 149.518 120.0 6.00 8.00 8
219 2.652246305 64.00 3.02 1.597656988 39.59651714 48004050 48.004 197.522 197.522 120.0 8,00 10.00 8
215 2.667971008 64.00 3.00 1.545966601 35.15334048 42617453 42.617 240.139 240.139 120.0 10.00 12.00 8
208.5 2.693925199 64.00 2.97 1.460104381 28.84724753 34972387 34.972 275.112 275.112 120.0 12.00 14.00 8
203 2.716284123 64.00 2.95 1.385604335 24.29989153 29459490 29.459 304.571 304.571 120.0 14.00 16.00 8
198 2.736934937 64.00 2.92 1.316369513 20.71903446 25118309 25.118 329.690 329.690 240.0 16.00 20,00 8
192.5 2.76001656 64.00 2.90 1.238512267 17.31857949 41991671 41.992 371.681 371.681 240.0 20.00 24.00 8
187.5 2.781340297 64.00 2.88 1.16615147 14.66059074 35546951 35.547 407.228 407.228 720.0 24.00 36.00 8
180 2.813950943 64.00 2.84 1.05470673 11.34244624 82504734 82.505 489.733 489.733 720.0 36.00 48.00 8
170 2.85864024 64.00 2.80 0.90050012 7.952434858 57845857 57.846 547.579 547.579 1440.0 48.00 72.00 8
160 2.904771895 64.00 2.75 0.73959323 5.490264025 79872148 79.872 627.451 627.451 2880,0 72.00 120.00 8
152.5 2.940359704 64.00 2.72 0.614318478 4.114513368 119715562 119.716 747.167 747.167 3240.0 120.00 174.00 8
143.5 2.984233301 64.00 2.68 0.458561939 2.874497526 94090677 94.091 841.257 841.257 3960.0 174.00 240.0 8
131.5 3.044809446 64.00 2.63 0.241233409 1.742743249 69721743 69.722 910.979 910.979 7200.0 240.00 360.00 8
121.35 3.098000069 64.00 2.58 0.048335897 1.1177274 81303274 81.303 992.282 992.282 7200,0 360.00 480.00 8
114.225 3.136462245 64.00 2.55
-0.09229352 0.808549245 58813715 58.814 1051.096 1051.096 7200.0 480.00 600.00 8
106.975 3.176592046 64.00 2.52
-0.24000228 0.575436914 41857170 41.857 1092.953 1092.953 7200.0 600,00 720.00 8
101.6 3,207012668 64.00 2.49
-0.35261926 0.443997723 32296308 32.296 1125.249 1125.249
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 316 of 492 Submerged Not-Submerged Total Al Min Time (hrs) (thick)
(thin)
Release 0.33 0.006 0.931395 0.1817 1.1131 0.50 0.0 2.2 0.36 2.59 1.00 0.0 6.9 0.86 7.74 1.50 0.0 12.1 1.32 13.40 5.00 0.1 51.6 4.05 55.63 10.00 0.2 109.6 7.10 116.65 15.00 0.3 164.5 9.36 173.84 20.00 0.3 172.3 11.49 183.78 25.00 0.4 174.3 14.23 188.52 30.00 0.5 176.0 16.15 192.14 45.00 0.8 180.0 20.26 200.30 60.00 1.0 183.3 24.43 207.75 90.00 1.5 189.4 36.25 225.70 120.00 2.0 195.3 49.17 244.50 240.00 4.0 216.7 100.08 316.77 360.00 6.0 235.0 149.52 384.51 480.00 8.0 249.7 197.52 447.26 600.00 10.0 261.5 240.14 501.67 720.00 12.0 271.6 275.11 546.76 840.00 14.0 280.3 304.57 584.87 960.00 16.0 287.7 329.69 617.37 1200.00 20.0 300.2 371.68 671.91 1440.00 24.0 310.7 407.23 717.90 2160.00 36.0 334.9 489.73 824.64 2880.00 48.0 352.2 547.58 899.80 4320.00 72.0 377.5 627.45 1004.97 7200.00 120.0 421.0 747.17 1168.19 10440.00 174.0 461.4 841.26 1302.63 14400.00 240.0 495.6 910.98 1406.63 21600.00 360.0 542.4 992.28 1534.64 28800.00 480.0 580.7 1051.10 1631.75 36000.00 600.0 610.3 1092.95 1703.28 43200.00 720.0 633.9 1125.25 1759.20 2000.000000 1800.000000 1600.000000 1400.000000 rn 1200.000000 dN 1000.000000 800.000000 600.000000 400.000000 200.000000 0.000000 0.000 Aluminum Release 10.000 20.000 30.000 40.000 50.000 Time (hrs)
Entergy Palisades Nuclear Power Plant Project No. 12122-005 Aluminum Metal Submerged 0.000 0.000 633.949 Aluminum Metal Not-Submerged 0.000 0. 000 1
, 125.249 Concrete 42.725 1.421 0.472 E-glass (Fiberglass, Nukon )
13.866 92. 570 3.519 Calcium Silicate (Cal-Sil, Marinite )
233.600 242. 929 1 0.000 TOTAL Released Material 290.191 336.920 1,763.189 Concentration in the sump (mg/kg (mass dissolved divided by the sump pool mass) 194.489 225.808 1,181.711 Document No. 2007-03464 Revision 0 Page 317 of 492 Si as Si02 MW Si 28.086 MW Si02 60.085 720.781 kg 483.076 mg/kg
Entergy Palisades Nuclear Power Plant Project No. 12122-005 Source of Material Release Mass of Precipitate (kg)
Ca3(PO4)2 NaAlSiO8 AIOOH Total Aluminum Metal Submerged 0.000 188.370 1,321.310 1,509.681 Aluminum Metal Not-Submerged 0.000 334.354 2,345.304 2,679.659 Concrete 110.229 2.349 0.984 113.563 E-glass (Fiberglass, Nukon) 35.775 144.992 7.334 188.101 Calcium Silicate (Cal-Sil, Marinite) 602.688 377.755 1 0.000 980.443 TOTAL Precipitate 748.692 1,047.822 3,674.932 1 5,471.446 Document No. 2007-03464 Revision 0 Page 318 of 492
Entergy Palisades Nuclear Power Plant Project No. 12122-005 Density of aluminum square feet to square cm cm to mils 2.6989 g/cm3 929.03 cm2/ft2 393.70 mil/cm Area - submerged 31,952 ft2 Area - submerged 29,684,088 cm2 Aluminum dissolved 633,949 grams Aluminum dissolved 234.892 cm3 Reduction in thickness 0.0079 cm Reduction in thickness 3.1154 mils Corrosion rate 37.9036 mils/year Original mass of aluminum 1,634 pounds 741 kg Fraction of mass dissolved 85.5%
Area - not submerged 108,745 ft2 Area - not submerged 101,027,367 cm2 Aluminum dissolved 1,125,249 grams Aluminum dissolved 416,929 cm3 Reduction in thickness 0.0041 cm Reduction in thickness 1.6248 mils Corrosion rate 19.7679 mils/year Original mass of aluminum 5,756 pounds 2,611 kg Fraction of mass dissolved 43.1%
Document No. 2007-03464 Revision 0 Page 319 of 492
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 320 of 492 Dissolved Chemicals
' Precipitate Al 1,763.1 Si (g)
I Si (ppm)
N Si02 (g) 1 Si02 483
ATTACHMENT 2 Results from WCAP-1 6530 - NP, Rev. 0 "Evaluation of Post-Accident Chemical Effects in Containment Sump Fluids to Support GSI-191" DOCUMENT No. 2007-03464, REVISION 0 Pages 88 to 125 of 492 SPREADSHEET FOR PALISADES NUCLEAR PLANT SODIUM TETRABORATE DECAHYDRATE (STB) BUFFER 39 Pages Follow
Entergy Attachment I Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 87 of 492 -B Results of WCAP-1 6530-N P, Rev. 0, (OG-06-255 and OG-06-378)
Spreadsheet for Palisades Nuclear Power Plant Unit 1, Break S2, Case 1 B, NaTB Buffer and 100% of the Aluminum and Water in the Reactor Cavity, pH 8
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122 -005 Page 88 of 492 Chemical Effects Calculation Use saturation pH for 20 minutes Palisades Unit 1 Start sump mixing after 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Stop spray after 30 days 5.1 SIRWTank Water pH 9.32 Initial Sump pH 8.0 Equilibrium pH Cases A 7 Equilibrium pH Cases B 8 Equilibrium pH Time step Start Time (sec)
Time (min)
Time (hour)
Time (day)
Sump Temp.
(°F)
Sump Temp.
Step Cont.
Temp.
(°F)
Cont Temp.
Step Sump pH Spray pH Sump Mixed 1=yes 1
10 0.2 0.00 0.00 228.0 280.0 9.3 5.1 0
2 20 0.3 0.01 0.00 250.0 22.00 281.0 1.00 9.3 5.1 0
3 30 0.5 0.01 0.00 260.0 10.00 279.0
-2.00 9.3 5.1 0
4 60 1.0 0.02 0.00 268.0 8.00 1:276.0
-3.00 9.3 5.1
- '.0 5
90 1.5 0.03 0.00 272.0 4.00 272.0
-4.00 9.3 5.1 0
6 300 5.0 0.08 0.00 277.0 5.00 265.0
-7.00 9.3 5.1 7
600 10.0 0.17 0.01 275.0
-2.00 is 255.0
-10.00 9.3 5.1 0
8 900 15.0 0.25 0.01 271.0
-4.00 245.0
-10.00 9.3 5.1 0
9 1200 20.0 0.33 0.01 268.0
-3.00 240.0
-5.00 8.0 8.0 0
10 1500 25.0 0.42 0.02 261.0
-7.00 220.0
-20.00 8.0 8.0 11 1800 30.0 0.50 0.02 255.0
-6.00 215.0
-5.00 8.0 8.0 12 2700 45.0 0.75 0.03 243.0
-12.00 198.0
-17.00 8.0 8.0 0
13 3600 60.0 1.00 0.04 239.0
-4.00 216.0 18.00 8.0 8.0 st.5 14 5400 90.0 1.50 0.06 238.0
-1.00 221.0 5.00 8.0 8.0 0
15 7200 120.0 2.00 0.08 236.0
-2.00 222.0 1.00 8.0 8.0 0
16 14400 240.0 4.00 0.17 231.0
-5.00 220.0
-2.00 8.0 8.0 0
17 21600 360.0 6.00 0.25 225.0
-6.00 220.0 0.0 8.0 8.0
=.0 18 28800 480.0 8.00 0.33 216.0
-9.00 218.0
-2.0 8.0 8.0 0
19 36000 600.0 10.00 0.42 210.0
-6.00 1.
212.0
-6.00 8.0 8.0 0
20 43200 720.0 12.00 0.50 206.0
-4.00 205.0
-7.00 8.0 8.0 1
21 50400 840.0 14.00 0.58 200.0
-6.00 201.0
-4.00 8.0 8.0 1
22
`157600 960.0 16.00 0.67 196.0
-4.00 195.0
-6.00 8.0 8.0 1
23 72000 1200.0 20.00 0.83 190.0
-6.00 190.0
-5.00 8.0 8.0 24 86400 1440.0 24.00 1.00 185.0
-5.00 185.0
-5.00 8.0 8.0 25 129600 2160.0 36.00 1.50 175.0
-10.00 175.0
-10.00 8.0 8.0 26 172800 2880.0 48.00 2.00 166.0
-9.00 165.0
-10.00 8.0 8.0 1
27 259200 4320.0 72.00 3.00 158.0
-8.00 155.0
-10.00 8.0 8.0 1
28 432000 7200.0 120.00 5.00 158.0 0.00
.150.0
-5.00 8.0 8.0 29 626400 10440.0 174.00 7.25 148.0
-10.00 137.0
-13.00 8.0 8.0 30 864000 14400.0 240.00 10.00 139.7
-8.30 126.0
-11.00 8.0 8.0 1
31 1296000 21600.0 360.00 15.00 134.0
-5.70 116.7
-9.30 8.0 8.0 32
- 1728000 28800.0 480.00 20.00 130.3
-3.70 111.8
-4.95 8.0 8.0 1
33
-2160000 36000.0 600.00 25.00
-1222
-8.10 102.2
-9.55 8.0 8.0 1
34 2592000 43200.0 720.00 30.00
.':120.0
-2.20 101.0
-1.20 8.0 8.0 1
Switchover to recirc at 20 minutes Start Mixing at 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> ratlure of DG 1-1 to Start Fig. 3 Fig.2 Failure of DG 1-2 to Start Fig. 13 Fig. 12 Sump Temp. Cont. Temp. Sump Temp.
Cont. Temp.
(°F)
(°F)
(°F)
(°F) 228.00 277.0 228.00 280.00 250.00 278.0 249.00 281.OC 259.00 278.0 260.00 279.00 264.00 276.00 268.00 276.00 269.00 272.00 272.00 272.00 271.00 262.0 277.00 265.00 270.00 252.00 275.00 255.00 268.00 234.00 271.00 245.00 260.00 221.00 268.00 240.00 254.00 213.0 261.00 220.00 249.00 200.00 255.00 215.00 231.50 174.00 243.00 198.00 229.00 185.0 239.00 216.00 227.00 190.00 238.00 221.00 220.00 189.00 236.00 222.00 215.00 180.00 231.00 220.00 198.00 178.00 225.00 220.00 192.00 178.0 216.00 218.00 182.00 172.00 210.00 212.00 174.00 166.00 206.00 205.00 170.00 162.00 200.00 201.00 166.00 158.00 196.00 195.00 162.00 155.00 190.00 190.00 157.00 152.0 185.00 185.00 151.00 147.00 175.00 175.00 148.00 140.00 166.00 165.00 144.00 150.00 158.00 155.00 158.00 150.0 143.00 140.00 148.00 137.00 138.30 129.00 139.70 126.00 134.00 120.60 134.00 116.70 123.00 113.00 130.30 111.75 118.20 106.19 122.20 102.2 114.40 101.74 120.00 100.00 112.00 101.00
Entergy Palisades Nuclear Power Plant Project No. 12122-005 Chemical Effects Calculation Case 1 B Buffer STB pH 8.00 Palisades RC Al 100.0%
Unit 1 Start sump mixing after 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Stop spray after 30 days Materials Input Coolant Sump Pool Volume (gal) 394,307 gal Sump Pool Volume (ft3) 52,715 ft3 Sump Pool Mass (lb) 3,289,406 lb Density 62.4 lb/ft3
% Aluminum in Reactor Cavity Available 100%
Aluminum Submerged 31,951.7 ft 1,633.9 Ito Aluminum Not Submerged 108,745.0 ft 5,756.0 lb Concrete conversion factor 1.01 E-05 kg/ft2 Latent Debris fiber 15.0%
30.0 lb Latent Debris particulate (cement) 85.0%
170.0 lb Concrete Particulate Concrete Concrete in Latent Debris 170.0 lb 77.1114941 kg Equivalent area of particulate concrete 7.67E+06 ft2 Exposed Concrete Submerged Solid Concrete (ft2) 679 ft2 Nonsubmerged Solid Concrete (ft2) 59,584 ft2 Total concrete area 7.73E+06 ft2 Trisodium Phosphate 11,000 Trisodium Phosphate Hydrate (Ibm) 0 lb 0 lb 3,289,406 lb inum in RC estered Water in RC r
brium pH sump pH Trisodium Phosphate Sump Pool Mass (lb)
TSP concentration This Case Water in the Reactor Cavity 4822 ft' Document No. 2007-03464 Revision 0 Page 89 of 492 100.0%
100.0%
50.0%
50.0%
0.0%
0.0%
100.0%
100.0%
0 0
2,411 2,411 4,822 4,822 0
0 STB STB STB STB STB STB TSP TSP 0.00 0.00 0.00 0.00 0.00 0.00 11,000 11,000 7.00 8.00 7.00 8.00 7.00 8.00 7.00 8.00 9.32 9.32 9.32 9.32 9.32 9.32 11.54 11.54
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 90 of 492 Insulation Break S2 Break S1 Break S2 Break S3 Break S4 Calcium Silicate CalSil (113) 153.3 ft3 127.60 153.26 114.03 92.73 Density 14.5 lb/ft3 Asbestos (ft3) 0.0 ft' 0.00 0.00 0.00 0.00 Density 10.0 lb/ft' Kaylo (ft3) 0.0 ft3 0.00 0.00 0.00 0.00 Density 14.5lb/ft' Unibestos (ft3) 0.0 ft' 0.00 0.00 0.00 0.00 Density 14.5 lb/ft3 E-glass Fiberglass (ft3) 50.1 ft3 160.61 50.06 159.89 0.64 Density 4.0lb/ft3 NUKON (ft3) 1139.0 ft3 1234.02 1139.05 875.03 302.13 Density 2.4lb/ft3 Temp-Mat (ft3) 0.0 ft3 0.00 0.00 0.00 0.00 Density 11.8lb/ft' Thermal Wrap (ft3) 0.0 ft3 0.00 0.00 0.00 0.00 Density 2.4 lb/ft3 Silica Powder Microtherm (ft3) 0.0 ft3 0.00 0.00 0.00 0.00 Density 15.0 lb/ft' Min-K (ft3) 0.0 ft3 0.00 0.00 0.00 0.00 Density 16.0lb/ft' Mineral Wool Min-Wool (ft3) 0.0 ft' 0
0 0
0 Density 10.0 lb/ft3 Rock Wool (ft3) 0.0 ft' 0
0 0
0 Density 10.0lb/ft' Aluminum Silicate Cerablanket (ft3) 0.0 ft3 0
0 0
0 Density 12.0lb/ft' FiberFrax Durablanket (ft3) 0.0 ft3 0
0 0
0 Density 12.0 lb/ft3 Kaowool (ft3) 0.0 ft3 0
0 0
0 Density 12.0 lb/ft3 Mat-Ceramic (ft3) 0.0 ft3 0
0 0
0 Density 12.0 lb/ft3 Mineral Fiber (ft3) 0.0 ft3 0
0 0
0 Density 21.0 lb/ft3 PAROC Mineral Wool (ft3) 0.0 ft3 0
0 0
0 Density 21.0 lb/ft3 Interam Interam (ft3) 0.0 ft3 0
0 0
0 Density
'f:..:54.0lb/ft'
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 91 of 492 Assume particulate debris is insulation in mass proportion to the insulation Density Break S1 Break S2 Break S3 Break S4 (lb/ft3)
Calsil ZOI 35.51 60.98 21.86 0.00 ft3 Unjacketed 50.78 50.78 50.78 50.78 ft3 Total 86.29 111.76 72.64 50.78 ft3 Weight 14.5 1,251.21 1,620.52 1,053.28 736.31 lb Marinite 12.80 12.80 12.80
=
12.80 ft3 Weight 46 588.80 588.80 588.80 588.80 lb Total Weight 1,840.01 2,209.32 1,642.08 1,325.11 lb 33.9%
43.1%
37.6%
64.9% Weight %
Asbestos ZOI 0.00 0.00 0.00 0.00 ft3
- `.0.00 0.00 0.00 0.00 ft3 Total 0.00 0.00 0.00 0.00 ft3 10.0 0.00 0.00 0.00 0.00 lb 0.0%
0.0%
0.0%
0.0% Weight %
Total calcium silicate 1,840.01 2,209.32 1,642.08 1,325.11 lb Fiberglass ZIO 159.14 49.18 158.21 0.04 ft3 Unjacketed 0.59 0.59 0.59 0.59 ft3 Total 159.73 49.77 158.80 0.63 ft3 4.0 638.92 199.08 635.20 2.52 lb 11.8%
3.9%
14.6%
0.1 % Weight %
Temp-Mat ZOl ft3 ft3 Total 0.00 0.00 0.00 0.00 ft3 11.8 0.00 0.00 0.00 0.00 lb 0.0%
0.0%
0.0%
0.0% Weight %
Nukon ZOI 1,224.64 1,129.83 866.46 295.17 ft3 Thermal Wrap Unjacketed 2.59 2.59 2.59 2.59 ft3 Total 1,227.23 1,132.42 869.05 297.76 63 2.4 2,945.35 2,717.81 2,085.72 714.62 lb 54.3%
53.0%
47.8%
35.0% Weight %
Total E-Glass 3,584.27 2,916.89 2,720.92 717.14 Ib
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 92 of 492 Microtherm ZOl 113 Margin ft3 Spray & Submerge ft3 Margin ft3 Total 0.00 0.00 0.00 0.00 ft3 15.0 0.00 0.00 0.00 0.00 lb Total silica Powder 0.0%
0.00 0.0%
0.00 0.0%
0.00 0.0%
0.00 Weight %
lb Mineral Wool ZOI ft3 ft3 ft3 ft3 Total 0.00 0.00 0.00 0.00 ft3 10.0 0.00 0.00 0.00 0.00 lb 0.0%
0.0%
0.0%
0.0% Weight %
Cerafiber ZOl ft3 ft3 ft3 ft3 Total 0.00 0.00 0.00 0.00 ft3 12.0 0.00 0.00 0.00 0.00 lb 0.0%
0.0%
0.0%
0.0% Weight %
Total debris insulation weight 5,424.28 5,126.21 4,363.00 2,042.25 lb Checksum 100.0%
100.0%
100.0%
100.0% Weight O/o
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 93 of 492 Latent Debris - Fiber 30 lb Break Si Break S2 Break S3 Break S4 Density (Ib/ft3)
CalSil Weight %
33.9%
43.1%
37.6%
64.9%
Weight fiber 14.5 10.18 12.93 11.29 19.47 lb E quivalent fiber volume 0.70 0.89 0.78 1.34 ft3 Asbestos Weight %
0.0%
0.0%
0.0%
0.0%
Weight fiber 10.0 0.00 0.00 0.00 0.00 lb Equivalent fiber volume 0.00 0.00 0.00 0.00 ft3 Fiberglass Weight %
11.8%
3.9%
14.6%
0.1%
Weight fiber 4.0 3.53 1.17 4.37 0.04 lb Equivalent fiber volume 0.88 0.29 1.09 0.01 ft3 Temp-Mat Weight %
0.0%
0.0%
0.0%
0.0%
Weight fiber 11.8 0.00 0.00 0.00 0.00 lb Equivalent fiber volume 0.00 0.00 0.00 0.00 ft3 Nukon Weight %
54.3%
53.0%
47.8%
35.0%
Weight fiber 2.4 16.29 15.91 14.34 10.50 lb Equivalent fiber volume 6.79 6.63 5.98 4.37 ft3 Microtherm Weight%
0.0%
0.0%
0.0%
0.0%
Weight fiber 15.0 0.00 0.00 0.00 0.00 lb Equivalent fiber volume 0.00 0.00 0.00 0.00 ft3 Mineral Wool Weight %
0.0%
0.0%
0.0%
0.0%
Weight fiber 10.0 0.00 0.00 0.00 0.00 lb Equivalent fiber volume 0.00 0.00 0.00 0.00 ft3 Cerafiber Weight %
0.0%
0.0%
0.0%
0.0%
Weight fiber 12.0 0.00 0.00 0.00 0.00 lb Equivalent fiber volume 0.00 0.00 0.00 0.00 ft3 Check
% TOTAL 100.00%
100.00%
100.00%
100.00%
Check Fiber total 30.00 30.00 30.00 30.00
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 94 of 492 Total Insulation volume Break S1 Break S2 Break S3 Break S4 ft3 ft3 ft3 ft3 Calsil Insulation 126.90 152.37 113.25 91.39 Includes Matinite board Latent Debris 0.70 0.89 0.78 1.34 TOTAL 127.60 153.26 114.03 92.73 Asbestos Insulation 0.00 0.00 0. 00 0.00 Latent Debris 0.00 0. 00 0.00 0.00 TOTAL 0.00 0.00 0. 00 0.00 Fiberglass Insulation 159.73 49.77 158. 80 0.63 Latent Debris 0.88 0.29 1.09 0.01 TOTAL 160.61 50.06 159.89 0.64 Temp-Mat Insulation 0.00 0.00 0.00 0.00 Latent Debris 0.00 0.00 0.00 0.00 TOTAL 0.00 0.00 0. 00 0.00 Nukon Insulation 1227.23 1132.42 869.05 297.76 Latent Debris 6.79 6.63 5.98 4.37 TOTAL 1234. 02 1139.05 875.03 302.13 Microtherm Insulation 0. 00 0.00 0. 00 0.00 Latent Debris 0.00 0. 00 0.00 0.00 TOTAL
- 0. 00 0.00 0. 00 0.00 Mineral Wool Insulation 0.00 0.00 0. 00 0.00 Latent Debris 0.00 0.00 0. 00 0.00 TOTAL 0.00 0.00 0.00 0.00 Cerafiber Insulation 0.00 0.00 0. 00 0.00 Latent Debris 0.00 0. 00 0.00 0.00 TOTAL
- 0. 00 0.00 0. 00 0.00
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 95 of 492 GSI-191 Aluminum & Chemical Effects Evaluation Submerged Outside the Reactor Cavity Wetted Area (U)
Weight (lb)
Area (ft2)
Service Water Piping.
2433.0 4866.0 547.0 Aluminum Paint 1365.0 2730.0
-.-153.0 Aluminum Paint 107.0 214.0 3.0 Submerged Inside the Reactor Cavity Wetted Area (ft2)
Weight (lb)
Area (ft2)
Reactor Vessel 10688,0 21376.0 98.0 RV Cavity Walls 907.0 1814.0 32.0 Reactor Cavity Cir. Panels 223.0 447.0 7. 9 RV Insulation Supports 481.0 481.0 379.0 Reactor Cavity Wall Supports 19.8 19.8 338.0 Reactor Cavity Cir. Panel Supports 3.9 3.9 76.0 TOTAL 29,007.70 1,477.90 Non-Submerged Outside the Reactor Cavity (Exposed to Containment Spray)
Wetted Area (ft2)
Weight (lb)
Area (ft2)
Primary Coolant System 11,390.0 22,781.0 160.0 Primary Coolant Pumps 19,467.0 38,934.0 273.0 Pressurizer Surge Line 3,128.0 6,256.0 44.0 Pressurizer 799.0 1
, 597.0 28.0 Pressurizer 3,019.0 6,048.0 48.0 Service Water Piping 962.0 1,923.0 216.0 SIS Piping 3,271.0 6,542.0 735.0 MSL Pipe 1,139.0 2, 279.0 256.0 FW Pipe 1,613. 0 3,226.0 362.0 Miscellaneous Pipe 7,805.0 15,609.0 1792.0 Pressurizer Jacket 487.0 974.0 269.0 Pressurizer Jacket 596.0 1,193.0 337.0 Pressurizer Supports 144.0 144.0 133.0 Component Cooling Fan Blades 252.0 504.0 473.0 Light Fixtures 368.0 735.0 630.0 Aluminum Paint 0.0 0.0 0.0 108.745.0 F 755 n
Entergy Palisades Nuclear Power Plant Project No. 12122-005 Aluminum Summary 108,745.0
% Aluminum in Reactor Cavity Available 100%
ft2 lb Thick Aluminum Metal Submerged (sq ft) 5,370.7 1,340.0 Thin Aluminum Metal Submerged (sq ft) 23,637.0 137.9 Total Aluminum in Paint Submerged (sq ft) 2,944.0 156.0 Aluminum Paint Submerged (sq ft) 2,944.0 156.0 Total Aluminum in Paint Submerged (sq ft) 2,944.0 156.0 Thick Aluminum Metal Not-Submerged (sq ft) 34,726.0 5,231.0 Thin Aluminum Metal Not-Submerged (sq ft) 74,019.0 525,0 Aluminum Paint Not-Submerged (sq ft) 0.0 0.0 Aluminum Submerged 31,951.7 1,633.9 Aluminum Not Submerged 108,745.0 5,756.0 Attachment I Document No. 2007-03464 Revision 0 Page 96 of 492
Entergy Attachment I Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 97 of 492 Chemical-Effects Version 1.1, 8/31/2006 1.
Enter the pH and temperature vs. time profiles on the sheet "Time Temp pH input' a.
Replace the values in red b.
Addition instructions are provided in the comments associated with the cells in row 1.
Place cursor over the red triangles to view.
2.
Enter containment materials in the sheet labeled "Materials Input" a.
For the insulation materials, input the quantities that are wetted by the spray, transported to the sump pool, or are submerged.
- b. Aluminum is separated into two categories: that submerged in the sump pool and that impacted by the spray.
c.
Both the mass and surface area of aluminum should be entered.
If the mass is not known, enter a very large number (1,000,000 Ibm) for conservatism
- 3. Change default density values in the sheet labeled "Materials Conversions" if the default estimates are not correct for your plant. Otherwise, no entries are needed.
- 4. View the results of model in the sheet labeled "Results Table" a.
Results are given as a function of time
- b. The elemental releases of Ca, Al and Si are given, as well as the masses of precipitates likely to form from them.
- 5. View a summary of the contribution of each material to the total elemental release in sheet "Releases by Material"
- 6. View a summary of the contribution of each material to each of the precipitates in the sheet "Precipitate by Material" 7.
Detailed information on the release of each material component with time is located in subsequent sheets that need not be examined.
Entergy Attachment I Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 98 of 492
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 99 of 492 52714.8 31951.7 1633.9 108745.0 5756.0 153.3 0.0 0.0 0.0 50.1 1139.0 0
0 0
0 0
0
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Pagel 00 of 492
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 101 of 492 Interval Duration (min) 0.2 Startof Interval (hrs) 0.00 End of Interval (hrs) 0.0 Average Interval pH 9.32 Average Temp (F) 239 a Release (kg) 0.0083 i Release (kg) 0.0701 Al Release (kg) 0.2725 NaAISi3O8 Precipitate (kg) 0.218 AIOOH Precipitate (kg) 0.555 Ca3(PO4)2 Precipitate (kg) 0 000 0.2 0.01 0.0 9.32 255 0.02 0.17 0.59 0.5 1.2 0 00 0.5 0.01 0.0 9.32 264 0.05 0.51 1.59 1.6 3.2 0.00 0.5 3.5 5.0 0.02 0.03 0.08 0.0 0.1 0.2 9.32 9.32 9.32 270 274.5 276 0.07 0.28 0.58 0.90 3.86 8.19 2.61 9.77 19.34 2.8 12.0 25.5 5.2 18.9 37.1 0.00 0.00 0.00 5.0 0.17 0.3 9.32 273 0.88 12.26 27.69 38.1 52.8 0.00 5.0 0.25 0.3 8.66 269.5 1.16 15.41 33.35 47.9 63.1 0.00 5.0 0.33 0.4 8
264.5 1.45 17.84 38.22 55.5 72.2 0.00 5.0 0.42 0.5 8
258 1.72 19.97 41.93 62.1 78.9 0 00 15.0 0.50 0.8 8
249 2.51 25.30 50.30 78.7 93.7 0.00 15.0 0.75 1.0 8
241 3.27 29.78 57.90 92.6 107.4 0.00 30.0 1.00 1.5 8
238.5 4.75 38.17 76.10 118.7 141.8 0.00 30.0 120.0 1.50 2.00 2.0 4.0 8
8 237 233.5 6.18 11.68 46.13 75.01 95.11 168.07 143.5 233.3 178.4 319.8 0.00 0.00 120.0 4.00 6.0 8
228 16.49 98.41 236.18 306.1 454.4 0.00 120.0 6.00 8.0 8
220.5 20.78 116.47 299.09 362.2 581.2 0.00 120.0 8.00 10.0 8
213 24.74 130.34 353.55 405.4 692.3 0.00 120.0 10.00 12.0 8
208 28.46 141.73 398.68 440.8 784.4 0.00 120.0 12.00 14.0 8
203 30.15 145.39 436.79 452.2 866.4 0.00 120.0 14.00 16.0 8
198 32.00 148.73 469.29 462.5 936.2 0 00 240.0 16.00 20.0 8
193 36.06 154.85 523.83 481.6 1052.9 0.00 240.0 20.00 24.0 8
187.5 40.37 160.33 569.82 498.6 1151.1 0.00 720.0 24.00 36.0 8
180 55.19 174.66 676.56 543.2 1377.9 0.00 720.0 1440.0 36.00 48.00 48.0 72.0 8
8 170.5 162 70.16 101.59 186.28 205.66 751.72 856.89 579.3 639.6 1536.5 1756.2 0.00 0.00 2880.0 72.00 120.0 8
158 134.97 239.26 1020.11 744.1 2094.7 0.00 3240.0 120.00 174.0 8
153 142.85 269.60 1154.55 838.4 2371.6 0.00 3960.0 174.00 240.0 8
143.85 192.59 298.19 1258.55 927.4 2582.1 0.00 7200.0 240.00 360.0 8
136.85 213.73 329.34 1386.56 1024.2 2844.2 0.00 7200.0 360.00 480.0 8
132.15 238.74 329.34 1483.67 1024.2 3059.8 0.00 7200.0 480.00 600.0 8
126.25 287.00 329.34 1555.20 1024.2 3218.6 0.00 7200.0 600.00 720.0 8
121.1 290.19 329.34 1611.12 1
024.2 3342.7 0.00
Entergy Palisades Nuclear Power Plant Project No. 12122-005 Releases in kg Material Class Ca Si Al Metallic Aluminum Submerged 0.00 0.00 482.34 Metallic Aluminum Not-Submerged 0.00 0.00 1125.25 Calcium Silicate 233.61 242.93 0.00 E-Glass 13.83 84.99 3.07 Silica Powder 0.00 0.00 0.00 Mineral Wool 0.00 0.00 0.00 Aluminum silicate 0.00 0.00 0.00 Concrete 42.76 1.42 0.46 Interam 0.00 0.00 0.00 1600.00 1600.00 1400.00 1200.00 1000.00 v
800.00 600.00 400.00 200.00 0.00 Contribution to Elemental Releases by Each Material Document No. 2007-03464 Revision 0 Page 102 of 492 Minteram Concrete ElAluminum silicate O Mineral Wool ElSilica Powder O E-Glass 0 Calcium Silicate Metallic Aluminum Not-Submerged M Metallic Aluminum Submerged Ca Si Al Element
Entergy Palisades Nuclear Power Plant Project No. 12122-005 rreclpltate (K
)
Material Class Ca3(PO4)2 NaAISi3O8 AIOOH Metallic Aluminum Submerg ed 0.00 153.32 1000.75 Metallic Aluminum Not-Submerged 0.00 357.68 2334.65 Calcium Silicate 0.00 377.76 0.00 E-Glass 0.00 133.13 6.37 Silica Powder 0.00 0.00 0.00 Mineral Wool 0.00 0.00 0.00 Aluminum silicate 0.00 0.00 0.00 Concrete 0.00 2.36 0.95 Interam 0.00 0.00 0.00 Contributions to Precipitates by Material Document No. 2007-03464 Revision 0 Page 103 of 492 O Interam q Concrete Aluminum silicate El Mineral Wool El Silica Powder q E-Glass Silicate o Metallic Aluminum Not-Submerged Metallic Aluminum Submerged NaAlS1308 AIOOH Precipitate
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 104 of 492 Interval Start of End of ve release Amount Duration Interval Interval Ave Ave Temp Ca this rate interval pred above interval kg Integral kg Constants Value (min)
(hrs)
(hrs)
Interval pH (F) 100011(K')
Ca All Mat Mat Only Ca (ppm)
K k
R (mg/kg-release (kg) start Mass Ca released Ca released Mass Material ( kg) 1008.0058 0.2 0.00 0.01 9.32 239 2.576323586 0
0 0.00 10.51 8.62 8.62 8.62 0.001
-347 8 0 001 0 0014 Mass Element ( kg) 347.762 0.2 0.01 0.0 9.32 255 2.518644969 0.01 0.00 0.00 8.0 6.76 6.76 6.76 0,001
-347.8 0 001 0 00 a
-2.406 0.5 0.01 0.0 9.32 264 2.487321569 0.01 0.00 0,00 7.02 5.93 5.93 5.93 0.003
-347 8 0 003 0 01 b
-0.1759 0.5 0.02 0.0 9.32 270 2.466868584 0.03 0.00 0.00 6.40 5.44 5.44 5.44 0.003
-347.8 0 003 0 01 c
1.96702 3.5 0.03 0.1 9.32 274.5 2.451748233 0.05 0.01 0.01 5.98 5.11 5.11 5.11 0.018
-347 7 0 018 0 03 d
-2.35331 5.0 0.08 0.2 9.32 276 2.446749222 0.19 0.02 0,02 5.84 5.00 4.99 4.99 0.025
-3477 0 025 0 05 e
-0,15044 i
5.0 0,17 0.3 9.32 273 2.456767713 0.39 0.03 0.03 6.11 5.22 5.19 5.19 0.026
-347 7 0 026 0 08 f
1.82068 5.0 0.25 0.3 8.66 269.5 2.468560144 0.59 0.05 0,05 8.43 6.89 6,85 6.85 0,035
-347.6 0 035 0 11 5,0 0,33 44 8
264.5 2.485604209 0.78 0.08 0.08 11.89 9.30 9.2 9.25 0.04
-347.6 0 047 0 16 5.0 0.42 0.5 8
258 2.508116544 0.97 0.11 411 13.17 10.23 10.14 10.14 0.051
-347.6 0 051 0 21 15.0 0,50 0.8 8
249 2.5399 99238 1.15 0.14 0.14 15.22 11.69 11.58 11.58 0.175
-347.4 0 175 0 38 15.0 0.75 1.0 8
241 2.5689697 1.68 0.26 0,26 17,35 13.20 13.00 13.00 0.197
-347.2 0 197 0 58 30.0 1.00 1.5 8
238.5 2.578168641 2.19 0.39 0.3 18.09 13.72 13.42 13.42 0.406
-346.8 0.406 0 99 30.0 1.50 2.0 8
237 2.583719695 3.18 0.66 0.66 18.55 14.04 13.54 13.54 0.409
-346.4 0 409 1 40 120.0 2.00 4.0 8
233.5 2.596765584 4.14 0.94 0.94 19.68 14.83 14.12 44.12 1.708
-344.7 1 708 3 10 120.0 4.00 6.6 8
228 2.617534573 7.83 2.08 2.08 21.62 16.18 14.62 44.62 1.768
-342.9 1.768 4 87 120.0 6.00 8.0 8
220.5 2.646397224 11.05 3.27 3.27 24.64 18.26 15.84 55.84 1.916
-341.0 1 916 6 79 120.0 8.00 10.0 8
213 2.675903489 13.93 4.55 4.55 28.16 20.66 17,32 77.32 2.095
-338.9 2,095 8 88 120.0 10.00 12.0 8
208 2.695942606 16.58 5.95 5.95 30.84 2.47 18.13 18.13 2.193
-336.7 2 193 11 08 120,0 12.00 14.0 8
203 2.716284123 19.07 7.42 19,07 33,81 24.47 10,67 10.6 1.290
-335.4 1 29 12 37 120.0 14.00 16.0 8
198 2.736934937 20.21
.29 20.21 37.13 26.69 12.16 12.16 1.471
-333.9 1.471 13 84 240.0 16.00 20.0 8
193 2.757902156 21.45 9.28 21.45 40.83 29.14 13.83 13.83 3.346
-330,6 3 346 17 19 240.0 20.00 24.0 8
187.5 2.781340297 24.17 11.52 24.17 45.40 32.15 15.03 15.03 3.636
-326.9 3 636 20 82 720.0 24.00 36.0 8
180 2.813950943 27.06 13.96 27.06 52.63 36.85 17.91 17.91 12.997
-313.9 12 997 33 82 720.0 36.00 48.0 8
170.5 2.85637209 36.99 22.67 36.99 63.77 44.03 18.49 18.49 13.421
-300.5 13 421 47 24 1440.0 48.00 72.0 8
162 2.895426834 47.02 31.66 47.02 76.12 51.86 19.82 19.82 28.776
-271.7 28 776 76 02 2880.0 72.00 120,0 8
158 2.914177473 68.09 50.95 68.09 82.86 56.10 10,00 00.00 29.042
-242,7 29 042 105 06 3240.0 120.00 174.0 8
153 2.937960076 90.46 70.41 90.46 92.29 61.98 1.23 1.23 4.010
-238.7 4,010 109 07 3960.0 174.00 8
143.85 2.982502651 95.74 73.10 95.74 112.91 74.71 11.36 11.36 45.354
-193.3 45 354 154 42 7200.0 240.00 8
136.85 3.017501509 129.07 103.50 129.07 132.31 86.52 2.12 2.12 15.357
-78.0 I
15.357 169 78 7200.0 360.00 t
8 132.15 3.04146531 143.24 113.79 143.24 147.48 95.66 2.75 2.75 19.946 7200,0 480.00 8
126.25 3.072091753 160.00 127.16 160.00 169.42 108,76 6.05 6.05 43.885 M
43 885 233 61 7200.0 600.00 7O.O 8
191.1 3.099333643 192.35 156.57 192.35 191.67 121.92
-0.43 0,00 0.000 0.000 233.61
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 105 of 492 Interval Start of End of osi' release Amount Duration Interval Interval Ave Ave Temp Si this Mat rate interval pred above interval kg Si Integral kg Constants Value min hrs hrs Interval H
F 100017 Kl Si All Mat Onl y Si p m K
k R
m 1k release k
start Mass released Si released Mass Material
( kg) 1008.0058 0.2 0.00 0.01 9.32 239 2.576323586 0
0 0.00 186.83 92.21 92.21 92.21 0.015
-242.9 0 015 0 0155 Mass Element ( kg) 242.92939 0.2 0.01 0.0 9.32 255 2.518644969 0.05 0.01 0.01 169.87 120.62 120.61 120.61 0.020
-242.9 0.020 0 0 a
0.12735 0.5 0.01 0.0 9.32 264 2.487321569 0.11 0.02 0.02 161.32 139.56 139.54 139.54 0.070
-242.8 0.070 0 1 b
0.03197 0.5 0.02 0.0 9.32 270 2.466868584 0.34 0.07 0.07 155,96 153,50 153,43 153,43 0077
-242.7 0.077 0 2 c
0.71658 3,5 0.03 0.1 9.32 274.5 2.451748233 0.60 0.12 0,12 152.12 164,70 164.56 164,56 0.581
-242.2 0.581 0 8 d
7.5547 5.0 0.06 0.2 9.32 276 2.446749222 2.59 0.51 0.51 150.87 168.58 168.00 168.00 0.847
-241.3 0.847 1 6 e
-0.04084 5.0 0.17 0.3 9.32 273 2.456767713 5.49 1.06 1.08 153.38 160.89 159.76 159.76 0.805
-240.5 0.805 2 4 f
-2.02198 5.0 0.25 0.3 8.66 269.5 2.468560144 8.21 1.62 1.62 148.98 162.05 160.29 160.29 0.808
-239.7 0.808 3 2 5.0 0.33 0.4 8
264.5 2.485604209 10.33 2.16 2.16 145.96 159.27 156.91 156.91 0.791
-238.9 0.791 4 0 5.0 0.42 0.5 8
256 2.508116544 11.96 2.69 2.69 151.49 143.42 140.66 140.88 0.710
-238.2 0.710 4 7 15.0 0.50 0.8 8
249 2.539969238 13.39 3.17 3.17 159,66 123.66 121.20 121.20 1.833
-236.4 1.833 6 6 15.0 0.75 1.0 8
241,
2.5689697 16.96 4.39 4.39 167.49 108.04 105.20 105.20 1.591
-234.8 1.591 8 1 30.0 1.00 1.5 8
238.5 2.578168641 19.96 5.46 5,46 170.05 103.51 100.18 100.18 3.030
-231.8 3.030 11 2 30.0 1.50 2.0 8
237 2.583719695 25.58 7.49 7.49 171.61 100.87 96.46 96.46 2.917
-228.8 2.917 14.1 120,0 2.00 4.0 8
233.5 2.596765584 30.91 9.45 9.45 175.35 94.92 89.81 89.81 10.863
-218.0 10.863 25 0 120,0 4.00 6.0 8
228 2.617534573 50.27 16.73 16.73 181.46 86.17 78.23 78.23 9.463
-208,5 9.463 34 4 120.0 6.00 8.0 8
220.5 2.646397224 65.96 23.07 23.07 190.31 75.34 66.21 66.21 8.008
-200.5 8.008 42 4 120.0 8.00 10.0 8
213 2.675903489 78.06 28.44 28.44 199.81 65.67 56.32 56.32 6.813
-193.7 6,813 49 2 120.0 10.00 12.0 8
208 2.695942606 87.36 33.00 33.00 206.52 59.82 50.26 50,26 6.079
-187.6 6.079 55 3 120.0 12.00 14.0 8
203 2.716284123 94.99 37.08 94.99 213.57 54.41 30.21 30.21 3.654
-184.0 3.654 59 0 120.0 14.00 16.0 8
198 2.736934937 97.44 39.53 97.44 220.97 49.43 27.63 27.63 3.342
-180.6 3.342 62 3 240.0 16.00 20.0 8
193 2.757902156 99.68 41.77 99.68 226.75 44.83 25.29 25,29 6.119
-174.5 6.119 68 4 240.0 20.00 24.0 8
187.5 2.781340297 103.78 45.87 103.78 237.77 40.19 22.65 22.65 5.480
-169.0 5.480 73.9 720.0 24.00 36.0 8
180 2.813950943 107.45 49.54 107.45 250.92 34.53 19.74 19.74 14.330
-154.7 14.330 88 2 720,0 36.00 48.0 8
170.5 2.85637209 117.06 59.14 117.06 269.11 28.34 16.01 16,01 11.623
-143.1 11.623 99 9 1440.0 48.00 72.0 8
162 2.895426834 124.85 66.93 124.85 287.02 23.63 13.35 13.35 19.381
-123.7 19.381 119.3 2880.0 72.00 120.0 8
158, 2.914177473 137.84 79.92 137.84 296.04 21.66 11.57 11.57 33.596
-90.1 33.596 152.8 3240.0 120.00 174.0 8
153 2.937960076 160.35 102.44 160.35 307.89 19.39 9.29 9.29 30.338
-59.7 30.338 183 2 3960.0 174.00 2400 8
143.85 2.982502651 180.69 122.77 180.69 331.37 15.76 7.16 7.16 28.597
-31.1 28,597 211 7200.0 240.00 360.0 8
136.85 3.017501509 199.85 141.94 199.85 351.07 13.39 5.77 5.77 41.846 10.7 31.146 242 9 7200.0 360.00 480.0 8
132.15 3.04146531 220.73 162.81 220.73 365.23 11.97 4.74 4.74 34.379 34.4 0.000 242 9 7200.0 480.00 600.0 8
126.25 3.072091753 220.73 162.81 220.73 384.16 10.38 4.42 4.42 32055 32.1 0.000 242 9 7200.0 600.00 720.0 8
121.1 3.099333643 220.73 162.81 220.73 401.82 9.15 4.12 4.12 29.912 29.9 0.000 242.9
Entergy Attachment I Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 106 of 492 Interval Startof End of i
osi ve release Amount Duration Interval Interval Ave
- ]
- :^
Ca this rate interval pred above start interval kg Integral kg Constants Value min hrs hrs Interval H
Ca All Mat Mat Onl Ca (ppm)
K k
R m
/k release k
Mass Ca released Ca released Mass Material k
77.717619 0.2 0,00 0.01 9.32 239 2.576323586 0
0 0.000 75,30 58.51 58.51 58.51 0.001
-1000000 0 001 0 001 Mass Element ( kg )
1000000 0.2 0.01 0.0 9.32 255 2.518644969 0.01 0.00 0.001 66.33 67.79 67.79 67.79 0.001
-1000000 0 001 0 002 a
x0.15969 0.5 0.01 0.0 9.32 264 2.487321569 0.01 0.00 0.001 61.92 73.43 73.42 73.42 0.003
-1000000 0 003 0 004 b
-0.04542 0.5 0.02 0.0 9.32 270 2.466868584 0.03 0,00 0.003 59.20 77.36 77.35 77.35 0.003
-1000000 0 003 0 007 c
0.95477 3.5 0.03 0.1 9.32 274.5 2.451748233 0.05 0,01 0.005 57.26 80.40 80.39 80.39 0.022
-1000000 0 022 0 029 d
5.31705 5.0 0.08 0.2 9.32 276 2.446749222 0.19 0.02 0.020 56.63 81.43 81.40 81.40 0.032
-1000000 0 032 0 061 e
-0.07459 5.0 0.17 0.3 9.32 273 2.456767713 0.39 0.04 0.041 57.90 79.38 79.32 99.32 0.031
-1000000 0 031 0 092 f
-1.10803 5.0 0.25 0.3 8.66 269.5 2.468560144 0,59 0.06 0.062 63.66 86,27 86,19 86.19 0.033
-1000000 0 033 0 125 5.0 0.33 0.4 8
264.5 2.485604209 0.78 0.08 0.084 70.82 92.51 92.40 92.40 0.036
-1000000 0 036 0 161 5.0 0.42 0.5 6
258 2.508116544 0.97 0.11 0.108 74.41 87.35 87.22 87.22 0.034
-1000000 0 034 0 195 15.0 0.50 0.8 8
249 2.539969238 1.15 0.13 0,131 79.81 80.53 80.40 80.40 0.094
-1000000 0 094 0 289 15.0 0.75 1.0 8
241 2.5689697 1.68 0.19 0,194 85.06 74.79 74.62 74.62 0.087
-1000000 0 087 0 376 Note=
Large mass of element u 30.0 1.00 1.5 8
238.5 2.578168641 2.19 0.25 0.252 86 80 73 05 72 84 72 84 0 170 999999 because no limit to concrete ass 30,0 1.50 2.0 8
237 2.583719695 3.18 0.37 0.366 87.86 72 03 71 73 71 73 0 167 999999 0.170 0
0.546 mass is an exposed surface.
120.0 2.0 4.0 8
233.5 2.596765584 4.14 0.48 0.478 90.42 69,67 69.30 69 30 0 646
-999999
,167 0 646 0.713 1 35 If concrete in latent debris is bei 120.0 4.00 6.0 8
228 2.617534573 7.83 0.91 0 911 94 64 66 07 65 44 65 44 0 610 included, a fraction of B2 should 120.0 6.00 8.0 8
220.5 2.646397224 11.05 1.32 1.320 100 84 61 38 60 58 60 56 0 565
-999998 99999 0.610 1.969 used.
120.0 8.00 10,0 8
213 2,675903489 13.93 1.70 1.699 107 60 56 93 56 03 56 03 0 523 7
99999 0.565 2.534 120.0 10.00 12.0 8
208 2.695942606 16.56 2.05 2.049 112.45 54.09 53111 53.11 0.495 7
-999996 0.523 0 495 3.057 3 552 120.0 12.00 14.0 8
203 2.716284123 19.07 2.38 19.073 117.59 51.36 43.03 43.03 0.401
-999996 0 401 3 954 120.0 14.00 16.0 8
198 2.736934937 20.21 2.65 20.207 123.05 48.72 40.72 40.72 0.380
-999996 0 380 4 333 240.0 16.00 20.0 8
193 2.757902156 21.45 2.90 21.447 128.86 46.18 38.50 38.50 0.71
-999995 0 718 5 051 240.0 20.00 24.0 8
187.5 2.781340297 24.17 3.39 24.171 135.67 43.50 35.75 35.75 0.667
-999994 0 667 5 718 720.0 24.00 36.0 8
180 2.813950943 27.06 3.83 27.055 145,76 40.03 32.60 32.60 1.824
-999992 1 824 7 542 720.0 36.00 48.0 8
170.5 2.85637209 36.99 5.06 36.988 160.00 35.92 27.62 27.62 1.545
-999991 1 545 9 088 1440.0 48.00 72.0 8
162 2.895426834 47.02 6.09 47.019 174.35 32.52 23.75 23.75 2.658
-999988 2 658 11 746 2880.0 72.00 120.0 8
158 2.914177473 68.09 7.87 68.086 181.69 31.00 19.38 19.38 4.338
-999984 338 4
16 084 3240.0 120,00 174.0 8
153 2.937960076 90,46 10.78 90.458 191.44 29.1 15.39 15.39 3.875
-999980 3.875 19 959 3960.0 174,00 240.0 8
143.85 2.982502651 95.74 13.38 95.742 211.13 26.0 14.23 14.23 4.380
-999976 4 360 24 338 7200.0 240.00 360.0 8
136.85 3.017501509 129.07 16.31 129.075 228.02 23.81 10.33 10.33 5.783
-999970 5 783 30 121 7200.0 360.00 480.0 132.15 3.04146531 143.24 20,19 143.243 240.35 22.40 9.05 9.05 5.065
-999965 5 055 35 186 7200.0 480.00 600.0 8
126.25 3.072091753 160.00 23.58 160.005 257.09 20.72 7.82 7.82 4.378
-999960 4 378 39 564 7200.0 600.00 1 720.0 1
8 1
121.1 3.099333643 192.35 26.52 192.352 272.96 19.33 5.71 5.71 3.194
-999957 3.194 42.758
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Project No. 12122-005 Revision 0 Page 107 of 492 onstants Mass Material k
Mass Element k
a alue 77.71 6619 1000000 1.05597 Interval Duration (min) 0,2 0.2 0 5 Start of Interval (hrs) 0.00 0.01 0 01 End of Interval (hrs 0.01 0.0 0 0 Ave Interval pH 9.32 9.32 9 32 Ave Temp (F) 239 25 264 000/T (K 2.576323586 2.518644969 4
i All Mat 0
0.05 Si this Mat Only 0
0.00 i (ppm) 0.00 0.00 K
31.61 31.11 k
26,78 29.55 R
26.78 29.55 v
release rate (m26.8 29.55 interval pred release 0(000 0.000 Amount above start
-1000000
-1000000 interval kg S released-O.000 0.000 i
Integral k g
g Si released 0.0003 0.00 b
0.01483 0.5 0.02 0.0 9.32 270
- 2. 87321569 2 466868584 0.11 0 34 0.00 0 00 0.00 30.85 31.18 31.18 31.18 0.001
-100000()
0.001 0.00 c
0.11862 3.5 0.03 0.1 9.32 274 2 451748233 0 60 0 00 0.00 30.68 32.29 32.29 32.29 0.001
-1000000 0.001 0.00 d
3.50061 5.0 0.08 0.2 9.32 276 2 446749222 2 59 0 01 0.00 30.55 33.13 33.13 33.13 0.009
-1000000 0.009 0.01 e
I t
-0.01713
-0.74261 5.0 5.0 0.17 0.25 0.3 0,3 9.32 8 66 273 269 5 2.456767713 2 468560144 5.49 8 21 0.02 0.01 0.02 30.51 30.59 33.42 32.85 33.41 3283 33.41 32.83 0.013 0.013
-1000000
-1000000 0.013 0.013 0.03 0.04 5.0 0,33 0.4 8
264 5 2 485604209 10 33 0.03 0 03 0.03 30.01 33.04 33.02 33.02 0.013
-1000000 0.013 0.05 5.0 15.0 15.0 0.0.50 50 0.75 0,5 0.8 1.0 8
8 8
256 249 241 2.508116544 2.539969238 2 5689697 11.96 13.39 16 96 0.04 0.05 0 07 0.03 0.04 005 29.47 29.66 29.92 32.94 31,70 30.02 32.90 31,65 29.97 32.90 31.65 29.97 0.013 0,012 0.035
-1000000
-1000000
-1000000 0.013 0.012 0.035 0.06 0.08 0.11 Note=
Large mass of element u because no limit to concrete ass mass is an exposed surface.
If concrete in latent debris is be!
included, a fraction of B2 should used.
30.0 30.0 120.0 120,0 120.0 120.0 1.00 1.50 2.00 4.00 6.00 8.00 1.5 2.0 4.0 6.0 8.0 10.0 8
8 8
8 8
8 238.5 237 233.5 228 2205 213 2.578168641 2.583719695 2,596765584 2.617534573 2.646397224 2 675903489 19.96 25,58 30.91 50.27 65.96 78 06 0.10 0.14 0.18 0,35 0.52 0 67 0.07 0.10 0.14 0.18 0.35 0.52 30.15 30,23 30.28 30.38 30.56 30.80 28.56 28.12 27.85 2.2 26.29 25,02 28.49 28.03 27.2 27.07 25.98 24.60 28.49 28.03 27.72 27,07 25.98 24.60 0.033 0.065 0.065 0252 0.242 0229
-1000000
-1000000
-1000000
-999999
-999999
-999999 0.033 0.065 0.065 0.252 0.242 0.229 0.14 0.21 0.27 0,53 0.77 1.00 120.0 120.0 120.0 240.0 240.0 720.0 720.0 1440.0 10.00 12.00 14.00 16.00 20,00 24.00 36.00 48.00 12.0 1400 16.0 20.0 24.0 36.0 48.0 72.0 8
8 8
8 8
8 8
8 208 203 198 193 187.5 180 170.5 162 2.695942606 2.716284123 2.736934937 2.757902156 2.781340297 2.813950943 2.85637209 2 895426834 87.36 94.99 97.44 99.68 103.78 107.45 117.06 124 85 0.81 0.95 0.95 0.95 0,95 0.95 0.95 0 9 0.67 0.81 94.99 97.44 99.68 103.78 107,45 117.06 124 5
31.05 31.22 31.39 31.57 31.75 31.95 32.24 32,62 23.79 22.99 22.20 21.43 20.68 19.87 18.79 17.47 23.28 22439
-44.98
-44.72
-44,24
-44,66
-43.83
^t5.24 23.28 22.3 0.00 0.00 0.00 0.00 0.00 0.00 0.217 0.209 O.OOD 0.000 0.000 0.000 0.000 0.000
-999999
-999999
-999999
-999999
-999999
-999999
-999999
-999999 0.217 0.20 0.000 0.000 0.000 0.000 0.000 0.000 1.22 1.42 1.42 1.42 1.42 1.42 1.42 1.42 2880.0 3240.0 3960.0 72.00 120.00 174.00 120.0 174.0 240.0 8
8 8
158 153 143 85 2.914177473 2.937960076 2 982502651 137.84 160.35 180 69 0.95 0.9 0 95
.8 137.84 160.35 32.97 33.14 33.35 16.35 15.83 15.20
-45.56
-50.02
-57.88 0.00 0.00 0.00 0.000 0.000 0.000
-999999
-99999
-999999 0.000 0.000 0.000 1.42 1.42 1.42 7200.0 7200.0 7200.0 7200.0 240.00 360.00 480.00 600.00 360.0 480.0 600.0 720.0 8
8 8
8 136.85 132.15 126.25 121 1
3.017501509 3.04146531 3.072091753 3 099333643 199.85 220.73 220.73 220 73 0.95 0.95 0,95 0 95 180.69 199.85 220.73 220.73 22 7
33.76 34.08 34.31 34.60 14.08 13.27 12.73 12.08
-61.30
-64.52
-69.19
-65.01 0.0 0.00 0.00 0.00 0.0 00 0.000 0.000 0.000
-999999
-999999
-999999
-999999 0.000 0.000 0.000 0.000 1.42 1.42 1.42 1.42 0.
3 34.85 11.53
-61.51 0,00 0.000
-999999 0.000 1.42
Entergy Palisades Nuclear Power Plant Document No. 2007-03464 Revision 0 Project No. 12122-005 Page 108 of 492 Interval Startof End of osi ve Duration Interval Interval Ave Ave Temp Al this Mat release Amount Constants Value min hrs hrs Interval H
F 1000/T K' AI All Mat Onl AI rate interval pred above start interval kg AI Integral kg Mass Material (kg) 77.717619 0.2 0.00 0.01 9 32 239 2 576323586 0
y 0
(ppm )
K k
R m
1k release k
Mass released Al released Mass Element (kg )
1000000 0.2 0 01 0 0 9 32 255 2 518644969 0 18 0.00 14.52 13.23 13.23 13.23 0.000
-1000000 0.000 0.0002 a
2 35338 0 5 0 01 0 0 9 32 26 0.00 0.00 15.95 20.64 20.64 20.64 0.000
-1000000 0.000 0.00 b
0 06829 D 5 0 0 4
2.487321569 0.39 0,00 0.00 16.79 26.27 26.27 26.27 0.001
-1000000 0.001 0 00 c
2 D.0 9.32 270 2.466868584 1.06 0.00 0.00 17.36 30.75 30,75 30.75 0 001
-1000000 0 001 0 00
-0.70953 3.5 0.03 0.1 9.32 274.5 2.451748233 1.75 0.00 0 00 17 79 34 55 34 55 34 55 d
9.23778 5.0 0.08 0.2 9 32 276 -T446749222 6 55 0 01 0.009
-1000000 0.009 0.01 e
0.05404 5.0 0.17 0.3 9.32 273 2.4567 77713 12.96 0 02 0.01 0 02 17.94 17 65 35.91 33 24 35.89 33 2 35.89 0.014
-1000000 0.014 0.03 f
-3,34577 5.0 0,25 0.3 8.66 269,5 2.468560144 18 56 0 03 0 03 15 60 27 96 1
33.21 0.013
-1000000 0.013 0.04 5.0 0.33 0.4 8
264 5 2 485604209 22 35 0 03 27.91 27.91 0.011
-1000000 0,011 0.05 5 0 0 42 0 5 8
258 2 5081 0.03 13.68 22.59 22.53 22.53 0.009
-1000000 0.009 0.06 15 0 66544 25.62 0.04 0.04 T3.19 18.99 18.93 18.93 0.007
-1000000 0 007 0 07 0.50 0,8 8
249 2.539969238 28.10 0.04 0.04 12,52 14.66 14.81 14.81 0.017
-1000000 0 017 0 08 Note= Large mass of element u 15.0 30 0 0.75 1 00 1.0 8
241 2.5689697 33.71 0.06 0.06 11.94 11.88 11.83 11.83 0.014
-1000000 0.014 0 10 because no limit to concrete ass 30 0 1 50 1.5 2 0 8
238.5 2.578168641 38.80 0.06 0.06 11.76 11.07 11.01 11.01 0.026
-1000000 0.026 0 12 mass is a d
f 8
237 2.583719695 51.00 0,08 0.08 11.65 10.61 I
10.53 10.53 0,025
-1000000 0 025 0 15 n expose sur ace.
120.0 2.00 4.0 8
233.5 2.596765584 63.74 0,10 0.10 11.41 9 59 9 51 9 51 0 089 10000 If concrete in latent debris is bei 120.0 4.00 6.0 8
228 2.617534573 112 64 0 16 0 16 11 03 8 17 8
00 0,089 0.24 included, a fraction of B2 should 120,0 6.00 8.0 8
220 5 2 646397224 158 29 0 21 0 21 0
.06 8.06 0.075
-1000000 0.075 0.31 used.
120.0 8.00 10.0 8
213 2.675903489 200 45 0 25 0 25
.52 1
10 02 6.54 5 21 6.41 6.41 0.060
-1000000 0.060 0.37 120.0 10,00 12.0 8
208 2.695942606 236 95 0 28 0 28 9 70 4 47 5.08 5.08 0.047
-1000000 0.047 0.42 120.0 12.00 14.0 8
203 2.716284123 267.20 0.31 267 20 9 38 3 82 4.34
-104 94 4.34 0 DO 0.040
-1000000 0.040 0.46 120.0 14.00 16.0 8
198 2.736934937 292.74 0 31 292 74 9 07 3 26 101 8 0 00 0.000
-1000000
.000 0.46 240.0 16,00 20.0 8
193 2.757902156 314.53 0.31 314 53 8 77 2 77
-96 67 0 00
.000
-1000000
,OOD 0.46 240.0 2000 240 8
187.5 2.781340297 351.07 0.31 351.07 8 44 2 31
-93 96 0 00 0.000 0
-1000000
.000 0.46 720.0 24.00 36,0 8
180 2.813950943 381.90 0.31 361.90 8.00 1.80
-84 12 0 00 000 0 000
-1000000
-1000000 0.00 0
0.46 720,0 3600 48.0 8
170.5 2.85637209 453.44 0.31 453.44 7.46 1.30
-77.5 0.00 0 000
-1000000
,000 0 000 0.46 0 46 1440.0 48.00 72.0 8
162 2.895426834 503.81 0.31 503.81 7.00 0.96
-68.16 0.00 0.000
-1000000 0 000 0 46 2880.0 72.00 120.0 8
158 2.914177473 574.30 0.31 574.30 6.79 0.83
-69.49 0.00 0.000
-1000000 0 000 0 46 3240.0 120.00 174,0 8
153 2.937960076 683.69 0,31 683.69 6.53 0.69
-71.77 0,00 0 000
-1000000 0 000 0
3960.0 174.0 240,0 8
143.85 2.982502651 773.80 0.31 73.80 6.07 0.49
-62 09 0 00 0 000 1000000
.46 7200.0 240.00 360.0 8
136.85 3.017501509 843.49 0,31 843.49 5.74 0.38
-54 78 0 00 0 000
-1000000 0.000 0.46 7200.0 360.00 480.0 8
132.15 3.04146531 929.29 0.31 929,29 5.52 0.31
-52 23 0 00 0 000 1000000 0.000 0.46 7200.0 480,00 600.0 8
126.25 3.072091753 994.37 0.31 994,37 5.25 0.25
-46 44 0 00 0 000 1000000 0.000 0.46 7200.0 600.00 720.0 8
121,1 3.099333643 1042.31 0.31 1042 31 5 02 0 20
-41 28 0 00 0.000 0.46 0.000
-1000000 0.000 0.46
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 109 of 492 onstants Mass Material (kg )
Mass Element (kg) a alue 1330.8348 28.746032
- 1 82949 Interval Duration min 0.2 0.2 0 5 Start of Interval Ihrs 0.00 0.01 0 01 End of Interval hrs 0.01 0.0 0 0 Ave Interval H
9.32 9.32 9 32 Ave Temp F
239 255 26 000/i K) 2.576323586 2,518644969 a All Mat 0
0.01 Ca this Mat Only 0
0.00 a (ppm )
0.00 0.00 K
17.87 99.02 k
27.65 31.42 R
27.65 31.41 osi ive release rate (m g/k g-27.65 31.41 interval pred release k
0.006 0.007 Amount above start Mass
-29
-29 interval kg Ca released 0.0061 0.0070 Integral kg Ca released 0,01 0.01 6
0.06821 0.5 0.02 0.0 9.32 4
270 2.487321569 2 466868584 0.01 0 03 0.01 0 02 0.01 0 02 19.68 20 12 33.68 35 33.66 33.66 0.022
-29 0.0224 0.04 C
-0.47088 3.5 0.0 0.1 9.32 274 5 2 451748233 0 05 0 04 0 04 20 45
.24 36 35.20 35.20 0.023
-29 0.0234 0.06 d
3.67611 5.0 0.08 0.2 9.32 276 2.446749222 0.19 0.15 0 15 20 56
.44 36 84 36.37 36 57 36.37 36 57 0.169 0
-29 0.1694 0.23 e
0.02616 5.0 0.17 0.3 9.32 273 2.456767713 039 0.32 0 32 20 34 36 04 35 48 35 48
.243 0
-28 0.2433 0.47 f
-0.96191 5,0 0.25 0.3 8,66 269.5 2.468560144 0.59 0.47 0.47 18 10 33 74 32 85 32 85
.236 0 219
-28 28 0.2361 0.71 5.0 0,33 0.4 8
264.5 2.485604209 0.78 0.62 0.62 16 02 31 22 30 01 30 01 0 200 28 0.2186 0.93 5.0 0.42 0.5 8
258 2.508116544 0.97 0.75 0.75 15.64 29.70 28 27 28 27 0 188 27 0.1997 0 18 1.13 15.0 0.50 0.8 8
249 2.539969238
- 1. 15 0.88 0.88 15.11 27.68 26.07 26 07 0 520
-27 1
0 5203 1.31 1 8 15.0 0.75 1.0 8
241 2.5689697 1.68 1.23 1.23 14.64 25,96 23.78 23.78 0.475
-26 0 4747 3
2 31 30.0 1.00 1.5 238.5 2.578168641 2.19 1.55 1.55 14.49 25.43 2.72 22.72 0 907
-26 0 9070 3 22 30.
1.50 2.0 8
237 2.583719695 3.18 2.16 2.1 14.41 25.12 21.36 21.36
.853
-2 0 8530 4 07 120.0 2.00 4.0 8
233.5 2,596765584 4.14 2.73 2.73 14.20 24.41 19.72 19.72 3.150
-22 3 1496 7 22 120.0 4.00 6.0 8
228 2.617534573 7.83 4.84 4.84 13.89 23.31 15,19 15.19 2.426
-19 2 4258 9 64 120.0 6.00 8.0 8
220.5 2.646397224 11.05 6.46 6.46 13.46 21.87 11.37 11.37 1.815
-17 1.8151 11 46 120.0 8.00 10,0 8
213 2.675903489 13.93 7.68 7.68 13,04 20.48 8.42 8.42 1.344
-16 1 3439 12 80 120.0 10,00 12.0 8
208 2.695942606 16.58 8.58 8.58 12.76 19,59 6.41 6.41 1.024
-15 1 0241 13 83 120.0 12.00 14.0 8
203 2.716284123 19.07 9.27 19.07 12.48 18.73
-9.90 0.00 0.000
-15 0 0000 13 83 120.0 14.00 16.0 8
198 2.736934937 20.21 9.27 20.21 12.20 17.89
-11.74 0.00 0.000
-15 0.0000 13 83 240.0 16,00 20.0 8
193 2.757902156 21.45 9.27 21.45 11.93 17,08
-13.63 0.00 0.000
-15 0 0000 13 83 240.0 20.00 24.0 8
187.5 2.781340297 24.17 9.27 24.17 11.63 16.22
-17.49 0.00 0.000
-1 0 0000 13 83 720.0 24.00 36.0 8
180 2.813950943 27.06 9.27 27.06 11,22 15.09
-21.28 0.00 0.000
-15 0.0000 13 83 720.0 36,00 48,0 8
170,5 2.85637209 36.99 9.27 36.99 10.72 13,73
-33.66 0.00 0.000
-15 0 0000 13 83 1440.0 48.00 72,0 8
162 2.895426834 47.02 9.27 47.02 10.27 12.60
-45.05 0.00 0.000
-15 0 000 13 83 2680.0 72.00 120.0 8
158 2.914177473 68.09 9.27 68.09 10.07 12.08
-69.64 0.00 0 000
-15 0 000 13 83 3240.0 120.00 174.0 8
153 2.937960076 90.46 9.27 90.46 9.81 11.46
-94.23 0.00 0 000
-15 0 000 13 83 3960.0 174.00 240.0 8
143.85 2.982502651 95.74 9.27 95.74 9.35 10.39
-95.98 0 00 0 000
-15 0 000 13 83 7200.0 240.00 360.0 8
136.85 3,017501509 129.07 9.27 129.07 9.00 9.61
-128.23 0.00 0.000
-15 0 000 13 83 7200.0 360.00 480.0 8
132.15 3.04146531 143.24 9.27 143.24 8.77 9.12
-139.77 0.00 0 000 -
-15
-0 000 13 83 7200.0 480.00 600.0 8
126.25 3.072091753 160.00 9.27 160.00 8.48 8.52
-152.13 0 00 0 000
-15 0 000 13 7200.0 600.00 720.0 8
121.1 3.099333643 192.35 9 27 192 35 8 24 8 02 179 24 0 00
.83 0.000
-15 0.000 13.83
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 110 of 492 Interval Start of End of osi IiiWe Duration Interval Interval Ave Ave Temp Si this Mat release Amount Constants Value min hrs hrs Interval F
1000/T K' Si All Mat Onl Si rate interval pred above interval kg Si Integral kg Mass Material ( kg )
1330,835 02 0 00 0 01 9 32 239 2 576323586 0
y (ppm)
K k
R (m g/kg-release k
start Mass released Si released Mass Element (kg) 260.9767 0,2 0 01 0 0 9 32 255 2 518644969 0 05 0
0.00 195.95 244.77 244.77 244.77 0,054
-261 0,054 0.0543 a
5.20122 0,5 0.01 0.0 9,32 264 2 487321569 0 11 0.04 0 09 0.04 0 09 239.32 343.80 343,75 343.75 0.076
-261 0.076 413 b
0 10404 0 5 0 02 0 0 9 32 270 2 4668685 266.77 413,46 413.33 413.33 0,275
-261 0.275 0.41 C
1 50553 84 434 0.27 0.27 286.37 466,40 465,96 465,96 0.310
-260 0 31 0 72 3,5 0,03 0.1 9.32 274.5 2.451748233 0.60 0,48 0.48 301.78 509,85 509.04 509,04 2 371
-258 2 371 3 09 d
7.46511 5.0 0.08 02 9.32 276 2.446749222 2.59 2.07 2.07 307.06 525,08 521.55 521.55 3 470
-254 3 470 6 59 e
0.16247 5.0 0.17 0,3 9.32 273 2,456767713 5.49 4.39 4.39 296.58 494,99 487.66 487 66 3 245
-251 3 245 9
i f
-2.55813 5.0 0.25 0.3 8.66 269,5 2,468560144 8,21 6,57 6,57 243.06 360,75 351.00 351 00 2 336
-249 2 336
.80 12 5.0 0.33 0.4 8
2645 2,485604209 10,33 8,13 8,13 195.61 254.90 244,30 244,30 1,626
-247 1 626
.14 13 76 5.0 0.42 0.5 8
258 2.508116544 11.96 9,22 9.22 180.92 223,25 211.86 211.86 1.410
-246 1 410 15 17 15.0 0.50 08 8
249 2.539969238 13.39 10,17 10.17 162,01 185.05 173,44 173,44 3.462
-242 3 462 18 64 15,0 075 1.0 8
241 2.5689697 16.96 12,49 12.49 146.51 156,00 142.70 142.70 2.849
-239 2849 2 84 21 46 30.
1.00 1.5 238.5 2.578168641 19,96 14.40 14.40 141.92 147,77 132.8 132,78 5.301
-234 26 78 30,0 1,50 2.0 237 2.583719695 25.58 17.95 17.95 139.21 143.01 124.57 124,57 4.974
-229 4 974 31 76 120.0 2.00 4,0 233,5 2.596765584 30.91 2128 21,28 133,06 132.44 11125 111,25 17.767
-211 17 767 49 53 120,0 4.00 6,0 8
228 2,617534573 50.27 33.19 33.19 123.8 117.19 85.77 85,77 13.697
-198 13 697 63 22 120.0 6.00 8,0 8
220.5 2.646397224 65.96 42.37 42,37 112M 98.86 61.47 11.47 9,817
-188 9 817 73 04 120,0 8.00 10,0 8
213 2.675903489 78.06 48,95 48,95 101.1 83,09 42.87 42,87 6 847
-181 6 847 79 89 120,0 10.00 12,0 208 2.695942606 87.36 53,54 53,54 94.3 73,84 31 94 31 94 5 100 176 5 100 120,0 12.00 14.0 8
203 2.716284123 94.99 56.96 94.99 87.9 65.50
-5 27 0 00 0 000 176 0
84,99 120.0 140 16.0 8
198 2.736934937 97.44 56,9 97.44 81.85 58.00
-11,05 0 00 0 000
-176
.000 0 000 84,99 240.0 16,00 20,0 8
193 2.757902156 99.68 56,96 99.68 76.11 51 26
-15 86 0 00 0 000 176 84.99 240.0 20.00 24.0 8
187.5 2.781340297 103.78 56.96 103.78 70.17 44.65
-21,39 0 00 0 000
-176 0,000 0 000 84,99 720.0 24.00 36.0 8
180 2.813950943 107,45 56,95 107.45 22,67 36,85
-26 33 0 00 0 000
-176 0 000 84.99 720,0 36,00 48.0 8
1705 2,85637209 117,06 5696 117,06 54,10 28,70
-33.40 000 0.000
-176 0 000 84.99 84 99 1440,0 46,00 72.0 8
162 2.895426834 124.85 56.96 124.85 47.25 22.80
-37.45 0 00 0 000
-176 0 000 84 99 2880.0 72.00 120.0 8
158 2.914177473 137.84 56.96 137.84 44.27 20.42
-43 15 0 00 0 000 176 0
3240.0 120,00 174.0 8
153 2.937960076 160.35 56,96 160 35 40 77 17 75
-52 06 0 00
,000 84.99 3960,0 174,00 240.0 8
143,85 2,982502651 180,69 56,96 180,69 34 94 13 65
-56 96 0 00 0,000 0 000
-176 0,000 84,99 7200,0 240,00 360.0 8
136,85 3.017501509 199.85 56.96 199.85 30.95 11.11
-60 64 0 00 0 000
-176 176 0,000 0 0 84,99 7200,0 360,00 480.0 8
132.15 3.04146531 220.73 56.96 220,73 28 48 9 65
-65 12 0 00 0 000 00 84,99 7200,0 480.00 600.0 8
126,25 3.072091753 220.73 56 96 220 73 25 61 6 05 61 37 0 00
-176 0,000 8499 7200.0 600.00 720,0 8
121.1 3.099333643 220,73 56 96 220 73 23 30 6 86 58 13 0.000
-176 0,000 84.99 0,00 0,000
-176 0,000 00 84.99
Entergy Attachment I Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 111 of 492 onstants Mass Material (kg)
Mass Element (kg) a alue 1330.835 25.95128 3 72351 Interval Duration min 0.2
____ P,2 0 5 Start of Interval hrs
.00 1
F 0,01 0 01 End of Interval hrs 0.01 0.0 0 0 Ave Interval H
9.32 9.32 9 32 Ave Temp (F) 239 255 000/T K 2.576323586 2.518644969 l All Mat 0
0.18 Al this Mat only 0
0.00 l (Ppm )
0.00 0.00 K
4.66 5.83 k
15.14 26.37 R
15.14 26.36 osi ve release rate (m g /kg-15.14 26.36 interval pred release k
0.003 0.006 Amount above start Mass
-26
-26 interval kg Al released 0.003 0,006 Integral kg Al released 0.00336 0.009 b
0.14041 0.5 0.02 0.0 9.32 264 270 2.487321569 2 466868584 0.39 06 1
0.01 0 02 0.01 0 02 6.59 7 13 35.64 43 39 35.61 43 35.61 0.024
-26 0.024 0.033 c
-1.69396 3.5 0.03 0.1 9.32 274,5 2.451748233 1.75 0 04 0 04 7 57 50 18
,26 49 91 43.26 49 91 0.029 0
-26 0,029 0.062 d
10.35371 5.0 0.08 0.2 9.32 276 2.446749222 6.55 0.20 0 2 7 72 52 66 51 31 51 31
,232 0 34
-26 0.232 0.294 e
0.17064 5.0 0.17 0.3 9.32 273 2.456767713 12.96 0.43 0.43 7.42 47.82 45 07 45 07 1
0 300
-25 25 0.341 0 30 0.636
-4.17804 5.0 0.25 0.3 8.66 269.5 2.468560144 18.56 0 63 0 63 5 73 32 94 29 33 29 33 0 195 0
0.936 5.0 0.33 0.4 8
264.5 2.485604209 22.35 0.76 0.76 4.33 21 57 17 79 77 79 0 118
-25 25 0.195 0 1 1.131 5.0 0.42 0.5 8
258 2.508116544 25.62 0.84 0 84 3 96 17 37 13 70 33 70 0 091 18 1.249 15,0 0.50 0.8 8
249 2.539969236 28.10 0.90 0.90 3,50 12.79 9.51 9.51 0,190
-25
-24 0.091 0 190 1.340 1 530 15.0 0.75 1.0 8
241 2.5689697 33.71 1.03 1.03 3.13 9.67 6.50 6.50 0,130
-24 0 130 1 660 30.0 1.00 1.5 8
238.5 2.578168641 38.80 1.11 1.11 3.02 8.85 5.59 5.59 0.22
-24 0 223 1 883 30.0 1.50 2.0 237 2.583719695 51.00 1.26 1.26 2.95 8.39 4.80 4.80 0.192
-24 0 192 2 075 120.0 2.00 4.0 8
233.5 2.596765584 63.74 1.39 1.39 2.81 7.40 3.73 3.73 0.596
-23 0 596 2 671 120.0 4.00 6.0 8
228 2.617534573 112.64 1.79 1.79 2.59 6.06 1.87 1.87 0.298
-23 0 298 2 969 120.0 6.00 8.0 8
220.5 2.646397224 158.29 1.99 1.99 2.31 4.59 0.64 0.64 0.102
-23 0 102 3 071 120.0 8.00 0
8 213 2.675903489 200.45 2.06 2.06 2.06 3.46 0.00 0.00 0.000
-23 0,000 3 072 120.0 10.00 0
8 208 2.695942606 236.95 2.06 2.06 1.91 2,85
-0.23 0.00 0.000
-23 0,000 3 072 120.0 12.00 0
8 203 2.716284123 267.20 2.06 267.20 1.76 2.34
-353.62 0.00 0.000
-23 0 000 3 072 120.0 14.00 0
8 198 2.736934937 292.74 2.06 292.74 1.62 1.92
-344.63 0.00 0.000
-23 0 000 3 072 240.0 16.00 20.0 8
193 2.757902156 31453 2.06 314.53 1.50 1.57
-328,68 0.00 0.000
-23 0,000 3 072 240.0 20.00 0
8 187.5 2.781340297 351.07 2.06 351.07 1.37 1.25
-321.13 0.00 0.000
-23 0.000 3 072 720.0 24.00 36.0 8
160 2.813950943 381.90 2.06 381.90 1.20 0.92
-290.09 0-0 0.000
-23 0 000 3 072 720.0 36.00 48.0 8
170.5 2.85637209 453.44 2.06 453.44 1.02 0.61
-270.46 0.00 O.ODO
-23 0 000 3 072 1440.0 48.00 72.0 8
162 2.895426834 503.81 2,06 503.81 0.88 0.42
-240.48 0.00 0.000
-23 0,000 3 072 2880.0 72.00 120.0 8
158 2.914177473 574.30 2.06 574.30 0.81 0.35
-246.33 0.00 0.000
-23 0 000 3 072 3240.0 120.00 174.0 8
153 2.937960076 683.69 2.06 683.69 0.74 0.28
-256.04 0.00 0.000
-23 0.000 3 072 3960.0 174.00 240.0 8
143,85 2.982502651 773.80 2.06 773.80 0.62 0.18
-224.67 0.00 0.000
-23 0.000 3 072 7200.0 240.00 360.0 136.85 3.017501509 843.49 2.06 843.49 0.54 0.13
-200.51 0.00 0.000
-23 0 000 3 072 7200.0 360.00 480.0 8
132.15 3.04146531 929.29 2.06 929.29 0.50 0.10
-192.63 0.00 0.000
-23 0.000 3 072 7200.0 480.00 600.0 8
126.25 3,072091753 994.37 2.06 994.37 0.44 0.08
-173.01 0.00 0.000
-23 0 000 3 072 7200,0 600.00 720.0 8
121.1 3.099333643 1042.31 9.06 1042.31 0.40 0.06
-155.20 0,00 0.000
-23 0.000 3.072
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 112 of 492 Interval Start of End of Ave Positive Amount Duration Interval Interval Interval Ave Temp Si this Mat release rate interval pred above interval kg Si Integral kg Si Constants Value (min)
(hrs) hrs pH (F) 1000lr K)
Si All Mat Only Si (ppm K
k R
(mglkg-min release (kg) start Mass released released Mass Material k
0 0.2 0.00 0.01 9.32 239 2.576323586 0
0 0.00 91.54 12526.80 12526.50 12526.50 0.000 0
0 000 0 00000 Mass Element k
0 0.2 0.01 0.0 9.32 255 2.518644969 0.05 0.00 0.00 92.43 16193.51 16193.51 16193.51 0.000 0
0.000 0 000 a
1.17043 0.5 0.01 0.0 9.32 264 2.487321569 0.11 0.00 0.00 92.92 18616.54 18616.54 18616.54 0.000 0
0 000 0 000 b
0.10511 0.5 0.02 0.0 9.32 270 2.466868584 0.34 0.00 0.00 93.24 20391.13 20391.13 20391,13 0.000 0
0.000 0 000 C
-0.07315 3,5 0.03 0.1 9.32 274.5 2.451748233 0.60 0.00 0.00 93.48 21810.91 21810.91 21810.91 0.000 0
0 000 0 000 d
7.41106 5.0 0.06 0.2 9.32 276 2.446749222 2.59 0.00 0.00 93.56 22301.72 22301.7 22301.72 0.000 0
0 000 0 000 0.17893 5.0 0.17 0.3 9.32 273 2.456767713 5.49 0.00 0.00 93.40 21328.95 21328.95 21328.95 0.000 0
0 000 0 000 i f
-1.93332 5.0 0.25 0.3 8.66 269.5 2.468560144 8.21 0.00 0.00 79.45 15419.74 15419.74 15419,74 0.000 0
0.000 0 000 5.0 0.33 0.4 8
264.5 2.485604209 10.33 0.00 0,00 67.53 10890.10 10890.10 10890.10 0.000 0
0.000 0 000 5.0 0.42 0.5 6
258 2.508116544 11.96 0.00 0.00 67.27 9851.63 9851.63 9851.63 0.000 0
0.000 0 000 15.0 0.50 0.8 8
249 2,539969238 13.39 0.00 0.00 66.91 8549.22 8549.22 8549.22 D.DDD 0
0.000 0.000 15.0 0.75 1.0 8
241 2.5689697 16.96 0.00 0.00 66.59 7513.80 7513.80 7513.80 0.000 0
0.000 0 000 30.0 1.00 1.5 8
238.5 2.578168641 19.96 0.00 0,00 66.48 7212.32 7212.32 7212.32 0.000 0
0.000 0 000 30.0 1.50 2.0 8
23 2.583719695 25.58 0.00 0.00 66.42 7036,28 7036.28 7036.28 0.000 0
0.000 0 000 120.0 2.00 4.0 8
233.5 2.596765584 30.91 0.00 0.00 66.28 6639.28 6639.28 6639.28 0.000 0
0.000 0 000 120,0 4.00 6.0 8
228 2.617534573 50.27 0.00 0.00 66.04 6052.96 6052.96 6052.96 0.000 0
0.000 0 000 120.0 6.00 8.0 8
220.5 2.646397224 65.96 0.00 0.00 65.72 5323.13 5323.13 5323.13 0.000 0
0.000 0 000 120.0 8.00 10.0 8
213 2.675903489 78.06 0.00 0.00 65.40 4667.91 4667.91 4667.91 0.000 0
0.000 0 000 120.0 10.00 12.0 8
208 2.695942606 87.36 0,00 0.00 65.18 4269.53 4269.53 4269,53 0.000 0
0.000 0 000 120.0 12.00 14.0 8
203 2.716284123 94.99 0.00 94.99 64.96 3899.90
-1803.32 0.00 0.000 0
0.000 0 000 120,0 14.00 16.0 a
198 2.736934937 97.44 0.00 97.44 64.73 3557.37
-1797.66 0.00 0.000 0
0.000 0.000 240.0 16.00 20.0 8
193 2.757902156 99.68 0.00 99.68 64.50 3240.36
-1767.25 0.00 0.000 0
0.000 0 000 240.0 20.00 24,0 8
187.5 2.781340297 103.78 0.00 103.78 64.25 2919.30
-1796,35 0.00 0.000 0
0,000 0 000 720.0 24.00 36.0 8
180 2.813950943 107.45 0.00 107.45 63.90 2524.83
-1721.21 0.00 0.000 0
0.000 0 000 720.0 36.00 48.0 8
170.5 2.85637209 117.06 0.00 117.06 63.44 2090.35
-1766.67 0.00 0,000 0
0.000 0 000 1440.0 48.00 72.0 8
162 2.895426834 124.85 0.00 124.8 63.0 1756.76
-1723.26 0.00 0.000 0
0.000 0.000 2880,0 72.00 120.0 8
158 2.914177473 137.84 0.00 137.84 62.83 1616.08
-1929.52 0.00 0.000 0
0.000 0,000 3240.0 120.00 174.0 6
153 2.937960076 160.35 0.00 160.35 62.57 1453.73
-2271.59 0.00 0.000 0
0.000 0.000 3960.0 174.00 240,0 8
143.85 2.982502651 180.69 0.00 180,69 62.11 1192,25
-2276,35 0.00 0.0110 0
0,000 0 000 7200.0 240.00 360.0 8
136.85 3.017501509 199.85 0.00 199.85 61.74 1020.24
-2282.20 0.00 0.000 0
0.000 0.000 7200.0 360.00 480.0 8
132.15 3.04146531 220.73 0.00 220.73 61.49 917.01
-2374.57 0,00 0.000 0
0.000 0 000 1
720.0 480.00 600.0 8
126.25 3.072091753 220.73 0.00 220.73 61.18 800.14
-2086.78 0.00 000 0
0.000 0 000 7200.0 600.00 720.0 8
121.1 1
3.099333643 220.73 0.00 220.73 60.90 708.76
-1860.22 0.00 0.000 0
o.o00 0.000
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 113 of 492 onstants Mass Material (kg)
Mass Element (kg) a alue 0
0 5 529 Interval Duration min 0.2 0,2 0 5 Start of Interval hrs 0.00 0.01 0 01 End of Interval hrs 0.01 0.0 0 0 Ave Interval H
9.32 9.32 9 32 Ave Temp F
239 255 000ff K'
2.576323586 2.518644969 l All Mat 0
0.18 Al this Mat Only 0
0.00 l (ppm) 0,00 0.00 K
19.58 27.34 k
72,45 112.60 R
72.45 112.60 asi ve release rate (m g/k g-72.45 112.60 interval pred release k
0,000 0.000 Amount above start Mass 0
0 interval kg Al released 0,000 0.000 Integral kg Al released 0,00000 0,000 b
0.2401 0,5 0,02 0.0 9,32 264 270 2.487321569 2.466868584 0.39 1 06 0.00 0 00 0.00 0 00 32.77 36 89 143.07 167 29 143.07 167 29 143.07 167 2 0,000 0
0.000 0,000 C
-2.51326 3,5 0,03 0.1 9.32 274,5 2.451748233 1.75 0 00 0 00 40 26 187 79 187 79 9
187 79 0,000 0 000 0
0.000 0.000 d
8.48062 5.0 0.08 0.2 9.32 276 2.446749222 6.55 0,0 D 0.00 41 44 195 10 195 10 195 10 0 000 0
D 0,000 0,000 I s 0.20749 5.0 0.17 0.3 9.32 273 2.456767713 12.96 0.0 0.00 39.11 180.72 180 72 180 72 0 000 0
0,000 0 000 0,000 f
-3.32039 5,0 0,25 0.3 8.66 269,5 2.468560144 18.56 0.00 0,00 25.36 120.48 120 48 120 46 0 000 0
0 000 0,000 0 0 5,0 0,33 0,4 8
264,5 2.485604209 22.35 0.00 0,00 15,95 77.16 77,16 77,16 0.000 0
0,000 00 0 000 5,0 0,42 0.5 8
256, 2.508116544 25.62 0.00 0.00 14.00 64.96 64,96 64,96 0.000 0
0 000 0 000 15,0 0,50 0.8 8
249 2.539969238 28,10 0,00 0,00 11.65 50,92 50,92 50,92 0,000 0
0 000 0 000 15,0 0,75 1,0 8
241 2,5689697 33.71 0,00 0,00 9.85 40,79 40,79 40 79 0 000 0
a 0 000 30.0 1.00 1.5 8
238.5 2.578168641 38.80 0.00 0.00 9,34 38,02 38,02 38.02 0.000 0
0.000 0 000 30.0 1.50 2.0 8
237 2.583719695 51.00 0,00 0,00 9,04 36.44 36,44 36.44 0,000 0
0 000 0 000 120.0 2,00 4,0 8
233,5 2.596765584 63.74 0,00 0,00 8,38 32,98 32,98 32,98 0,000 0
0,000 0 000 120,0 4,00 6,0 8
228 2.617534573 112.64 0,00 0,00 7,43 28,14 28.14 28,14 0,000 0
0,000 0 000 120.0 6,00 8,0 8
220,5 2.646397224 158.29 0.00 0,00 6,29 22.57 22.57-22.57-0.000-0 0.000 0 000 121: 1 1 8,00 10,0 213
, 2.675903489 200.45 0.00 0,00 5,30 18.01 18.01 18.01 0.000 0
0 000 0 000 6
120 10,00 12,0 8
208 2,695942606 236,95 0,00 0.00 4.72 15,45 15,45 15,45 0,000 0
0 000 0 000 120.0 12.00 14.0 8
203 2.716284123 267.20 0,00 267.20 4.20 13,23
-828.52 0.00 D,ODD 0
0,000 0 000 120.0 14.00 16,0 8
198 2.736934937 292.74 0,00 292.74 3,73 1.29
-876,20 0.00 0.000 0
0.000 000 0
240.0 16,00 20,0 8
193 2,757902156 314,53 0,00 314.53 3.30 9.62
-907.46 0.00 0,000 0
0 000 0 000 240,0 20,00 24,0 8
187,5 2,781340297 351.07 0,00 351.07 2.88 8,04
- 771.98 0.00 0.000 0
0.000 0 000 720.0 24.00 36.0 8
180 2.813950943 381.90 0,00 381.90 2,39 6.27
-997.11 0.00-0.000 0
0.000 0 000 720,0 36.00 48,0 8
170,5 2.85637209 453.44 0,00 453.44 1,87 4,53
-1 996.49 0.00 0,000 0
0 000 0 000 1440,0 48,00 72,0 8
162 2.895426834 503.81 0,00 503,81 1.49 3,36
-1134.32 0.00 0.000 0
0 000 0 000 2880,0 72.00 120,0 8
158 2.914177473 574.30 0,00 574.30 1.34 2.91
-1249.54 0.00 0.000 0
0,000 000 0
3240.0 120.00 174,0 8
153 2.937960076 683.69 0,00 683.69 1.16 2.43
.1424.11 0.00 000 0
0 0 000 0 000 3960.0 174.00 240.0 8
143.85 2.982502651 773,80 0,00 773.80 0,90 1.73
-1484.55 0.00 0,000 0
0,000 0 000 7200.0 240.00 360.0 8
136.85 3.017501509 843,49 0.00 843.49 0.73 1.32
-1516.80 0 00 0 000 0
0 000 0 000 7200.0 360.00 480,0 8
132,15 3.04146531 929.29 0.00 929.29 0.64 1.10
-1598.58 0 00 0 000 D
0 000 O OOD 7200,0 480.00 600.0 6
126,25 I 3.072091753 1
994.37 0.00 994,37 0,54 0.87
-1616 14 0 00 0 000 0
0 000 7200,0 600.00 720,0 8
3.099333643 1042.31 6 00 1042 31 0 46 0 71
-1610 58 0 00 0.000 0,000 0
0.000 0.000
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 114 of 492 onstants alue Interval Duration min Start of Interval hrs End of Interval
( hrs )
Ave Interval i
Ave Temp F
000lr K' i All Mat Si this Mat Only i (ppm)
K k
R Positive release rate (m g/kg-interval pred release k
Amount above start Mass interval kg Si released Integral kg Si released Mass Material (kg )
Mass Element (kg) a 0
0 7.51336 0,2 0.2 0.5 0.00 0.01 0.01 0.01 0,0 0.0 9.32 9.32 9.32 239 255 264 2.576323586 2.518644969 2.487321569 0
0.05 0.11 0
0.00 0.00 0.00 0.00 0.00 62.87 92.30 113.71 99.88 137.83 164.18 99.88 137.83 164.18 99.88 137.83 164.18 0.000 0.000 0.000 0
0 0
0.000 0.000 0.000 0.000 0,000 0 000 b
0.18619 0.5 0.02 0.0 9.32 270 2.466868584 0.34 0.00 0,00 130.30 184.04 184.04 184.04 0.000 0
0.000 0.000 c
-2.89181 3.5 0.03 0.1 9,32 274.5 2.451748233 0.60 0.00 0,00 144.10 200.26 200.26 200.26 0.000 0
.00 0,000 d
7.17588 5.0 0.08 0.2 9.32 276 2.446749222 2.59 0.00 0.00 148.98 205.93 205.93 205.93 0.000 0
0.000 0.000 e
0.11502 i f
-2.42532 5.0 5.0 5.0 0.17 0.25 0.33 0.3 0.3 0.4 9.32 8.66 8
273 269.5 264.5 2.456767713 2.468560144 2.485604209 5.49 8.21 10.L3-0.00 0.00 0.00 0.00 0.00 0.00 139.36 97.09 65.31 194.72 153.08 116.86 194.72 153.08 116.86 194.72 153.08 116.86 0.000 0.000 0.000 0
0 0
0.000 0.000 0.000 0.000 0.000 0.000 5.0 0.42 0.5 8
258 2.508116544 11.96 0.00 0.00 56.22 103.05 103.05 103.05 0.000 0
0.000 0.000 15,0 0.50 0.8 8
249 2.539969238 13.39 0,00 0.00 45.47 86.26 86.26 86.26 0.000 0
0.000 0.000 15.0 30.0 30.0 0.75 1.00 1.50 1.0 1.5 2.0 8
8 8
241 238.5 237 2.5689697 2.578168641 2.583719695 16.96 19.96 25.58 0,00 0.00 0.00 0.00 0.00 0.00 37.49 35.26 33.98 73.36 69.69 67.56 73.36 69.69 67.56 73.36 69.69 67.56 0.000 0.000 0.000 0
0 0
0.000 0.000 0.000 0.000 0.000 0.000 120.0 2.00 4.0 8
233.5 2.596765584 30.91 0.00 0.00 31.15 62.81 62.81 62.81 0.000 0
0.000 0,000 120.0 4.00 6.0 8
228 2.617534573 50.27 0.00 0.00 27.13 55.93 55.93 55.93 0.000 0
0.000 0,000 120.0 6.00 8.0 8
220.5 2.646397224 65.96 0.00 0.00 22.39 47.61 47.61 47.61 0.000 0
0.000 0.000 120.0 8.00 10.0 8
213 2.675903489 78.06 0,00 0.00 18.39 40.38 40.38 40.38 0.000 0
0.000 0.000 120.0 10,00 12.0 8
208 2.695942606 87.36 0.00 0.00 16.10 36.10 36.1 36.10 0.000 0
0.000 0.000 120.0 12.00 14.0 8
203 2.716284123 94.99 0.00 94.99 14.05 32.22
-185.53 0.00 0.000 0
0.000 0.000 120.0 14.00 16.0 8
- 198, 2.736934937 97.44 0.00 97.44 12.25 28.71
-199.66 0.00 0.000 0
0.000 0.000 240.0 16.00 20.0 8
193 2.757902156 99.68 0.00 99.68 10.65 25.54
-213.41 0.00 0,000 0
0.000 0.000 240.0 20.00 24.0 8
187.5 2.781340297 103.78 0.00 103.78 9.12 22.41
-232.71 0.00 0.000 0
0.000 0.000 720.0 24.00 36.0 8
180 2.813950943 107.45 0.00 107.45 7.34 18.68
-254.89 0.00 0.000 0
0.000 0.000 720.0 36.00 48.0 8
170.5 2.85637209 117.06 0.00 117.06 5.53 14.74
-297.17 0,00 0,000 0.000 0.000 1440.0 48.00 72.0 8
162 2.895426834 124.85 0.00 124.85 4.26 11.85
-335.07 0.00 0.000 0
0.000 0.000 2880.0 72.00 120.0 6
158 2.914177473 137.84 0.00 137.84 3.76 10.67
-380.13 0.00 0.000 0
0.000 0.000 3240.0 3960.0 120.00 174.00 174.0 240.0 8
8 153 143.8 2.937960076 2.982502651 160.35 180.69 0.00 0.00 160.35 180.69 3.21 2.39 9.34 7,29
-457.06
-544,02 0.00 0.00 0.000 0.000 0
0 0.000 0.000 0.000 0.000 7200.0 240.00 360.0 8
136.85 3.017501509 199.85 0.00 199.85 1.89 5.99
-627.15 0.00 0.000 0
0.000 0.000 7200.0 360.00 480.0 8
132.15 3.04146531 220.73 0.00 220.73 1.61 5.24
-712.27 0.00 0.000 0
0.000 0.000 7200.0 480.00 600.0 8
126.25 3.072091753 220.73 0.00 220.73 1.32 4.42
-737.09 0.00 0.000 0
0.000 0.000 7200.0 600.00 720.0 8
121.1 3.099333643 220.73 0.00 220.73 1.10 3.79
-759.73 0.00 0.000 0.000 0,000
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 115 of 492 Constants Mass Material (kg)
Mass Element ( kg) a Value 0
0 2 3015 Interval Duration (min) 0.2 0.2 D 5 Startof Interval (hrs) 0.00 0.01 End of Interval (hrs) 0.01 0.0 Ave Interval H
9.32 9.32 Ave Temp (F) 239 255 1000/T (K')
2.576323586 2.518644969 Ca All Mat 0
0.01 Ca this Mat Only 0
0.00 Ca (ppm 0.00 0.00 K
19.74 22.03 k
29.79 31.94 R
29.79 31.94 release rate (mg/kg-29.79 31.94 interval pred release (kg) 0.000 0,000 Amount above start Mass 0
0 interval kg Ca released 0.000 0.000 Integral kg Ca released 0.0000 0.000 b
0.12022 0.5 0.01 0 02 0.0 0 0 9.32 9 32 264 270 2.487321569 2 466868584 0.01 0 03 0.00 0.0 23.38 33.17 33.17 33.17 0.000 0
0.000 0.000 c
0.00 0.00 24.30 34.00 34.00 34.00 0.000 0
0.000 0 000
-0.8254 3.5 0.03 0.1 9.32 274.5 2.451748233 0.05 0.00 0.0 25.01 34.62 34.62 34 62 0 000 0
0 000 0 000 d
1.9854 5.0 0.08 0.2 9.32 276 2.446749222 0.19 0.00 0.00 25.25 34 83 34 83 34 83 0 000 0
e 0.0900 5.0 0.17 0.3 9.32 273 2.456767713 0.39 0 00 0 00 24 77 34 41 34 41 34 41 0.000 0.00 i f
-0.5244 5.0 0.25 0.3 8.66 269.5 2.468560144 0.59 0.00 0.00 20.1 29.59 29.59 29 59 0.000 0 000 0
0 0.000 0 000 0.000 5.0 0.33 0.4 8
264,5 2.485604209 0.78 0.00 0.0 16.27 25.27 25.27 25.27 0.000 0
0 000 0.000 0 000 5.0 0,42 0.5 8
258 2.508116544 0.97 0.00 0.00 15.59 24.60 24.60 24 60 0 000 0
0 00 15.0 0.50 0.8 8
249 2.539969238 1.15 0.00 0.00 14.68 23.67 23.67 23.67 0.000 0
0 000 0.000 0 000 15.0 0,75 1.0 8
241 2.5689697 1.68 0.00 0.00 13.89 22.85 22.85 22.85 0.000 0
0 000 0 000 30.0 1.00 1.5 8
238.5 2.578168641 2.19 0.00 0.0 13.65 22.60 22.60 22 60 0 000 0
0 000 0
30.0 1.50 2.0 8
237 2.583719695 3.18 0.00 0.00 33.51 22.45 22.45 22,45 0.000 0
0 000
.000 0 000 120.0 2.00 4.0 8
233.5 2.596765584 4.14 0.00 0.00 13.17 22.10 22.10 22.10 0.000 0
0 000 0 000 120.0 4.00 6.0 8
228 2.617534573 7.83 0.00 0.00 22.66 21.55 21 55 21 55 0 000 0
0 000 120.0 6.00 8.0 8
220.5 2.646397224 11.05 0.00 0.00 11.99 20.81 20.81 20,81 0.000 0
0 000 0.000 0 000 120,0 8.00 10,0 8
213 2.675903489 13.93 0.00 0.00 11.33 20.09 20.09 20 09 0 000 0
0 000 0 000 120.0 10.00 12.0 8
208 2.695942606 16.58 0,00 0.00 10.91 19.61 19.61 19.61 0.000 0
0 000 0 000 120.0 12.00 14.0 8
203 2.716284123 19.07 0.00 19,07 10,50 19.13
-15.63 0.00 0.00 0
0 000 0 000 120.0 14.00 16.0 8
198 2.736934937 20.21 0.00 20.21 10.09 18.65
-18.70 0.00 0.000 0
0 000 0 000 240.0 16.00 20.0 8
193 2.757902156 21.45 0.00 21.45 9.70 18.19
-22.04 0.00 0.000 0
0 000 0
0 240.0 20.00 24.0 8
187.5 2.781340297 24.17 0.00 24.17 9.28 17.68
-28.39 0.00 0.000 0
0 000 0 000 720.0 24.00 36.0 8
180 2.813950943 27.06 0.00 27.06 8.72 17.00
-35.75 0.00 0.000 0
0 000 0 000 720,0 36,00 48.0 8
170.5 2.85637209 36.99 11 0.00 36.99 8.04 66.15
-58.13 0.00 0.000 0
000 0 000 1440.0 48.00 72.0 8
162 2.895426834 47.02 0,00 47.02 7.47 15.41
-81.61 0 00 0 000 0
0 000 0
2880.0 72,00 120.0 8
158 2.914177473 68.09 0.00 68.09 7.21 15,06
-127.25 0.00 0.000 0
0 000
.000 0 000 3240.0 120.00 174.0 8
153 2.937960076 90.46 0,00 90.46 6.89 14.64
-177.59 0.00 0.000 0
0 000 0 000 3960.0 174.00 240.0 8
143.85 2.982502651 95.74 0.00 95.74 6.33 13.87
-195.96 0.00 0.000 0
0 000 0 000 7200.0 240.00 360.0 8
136.85 3.017501509 129.07 0.00 129.07 5.92 13.30
-276.54 0.00 0.000 0
0 000 0 000 7200.0 360.00 480.0 8
132.15 3.04146531 143.24 0.00 143.24 5.66 12.92
-314.12 0.00 0.000 0
0 000 0 000 7200.0 480.00 600,0 8
126.25 3.072091753 160.00 0.00 160.00 5.34 12.45
-360.70 0 00 0 000 0
0 000 0 0 7200.0 600.00 720.0 8
121.1 3.099333643 192.35 0.00 192 35 5 07 12 05
-445 09 0 00 0
. 00
.000 0
0.000 0.000
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 116 of 492 onstants alue Interval Duration min Start of Interval hrs End of Interval hrs Ave Interval H
Ave Temp F
000Ir (K' )
l All Mat Al this Mat Only l (ppm )
K k
R Positive release rate (m g/kg-interval pred release k
Amount above start Mass interval kg Al released Integral kg Al released Mass Material (kg )
0 0.2 0.00 0.01 9.32 239 2.576323586 0
0 0.00 8,79 17.12 17.12 17.12 0.000 0
0,000 0 000 Mass Element (kg) a b
0
-1:062762025 0.157710607 0.2 0.5 0.5 0.01 0.01 0.02 0.0 0.0 0.0 9.32 9.32 9.32 255 264 270 2.518644969 2.487321569 2.466868584 0.18 0.39 1.06 0.00 0.00 0.00 0.00 0.00 0.00 8.55 8.42 8.34 24.09 29.01 32.74 24.09 29.01 32,74 24.09 29.01 32.74 0.000 0.000 0,000 0
0 0
0,000 0,000 0.000 0.000 0.000 0.000 C
0.208439712 3.5 0.03 0.1 9.32 274.5 2.451748233 1,75 0.00 0,00 8.28 35.81 35.81 35.81 0.000 0
0.000 0 000 d
e f
6.629 0.13222
-2.57256 5.0 5.0 5,0 0.08 0.17 0.25 0.2 0.3 0.3 9.32 9.32 8.66 276 273 269.5 2.446749222 2.456767713 2.468560144 6.55 12.96 18.56 0.00 0.llO 0.00 0.00 0.00 0.00 8.26 8.30 6.57 36.89 34.76 26.52 36.89 34.76 26.52 36,89 34,76 26.52 0.000 0.000 0.000 0
0 0
0.000 0.000 0.000 0.000 0.000 0.000 5,0 0.33 0.4 8
264.5 2.485604209 22.35 0.00 0.00 5.21 19.61 19.61 19.61 0.000 0
0.000 0.000 5.0 0.42 0.5 8
258 2.508116544 25.62 0.00 0.00 5.27 17.16 17.16 17.16 0.000 0
0.000 0.000 15.0 0.50 0.8 8
249 2.539969238 28.10 0.00 0.00 5.35 14.21 14.21 14.21 0.000 0
0.000 0.000 15.0 30.0 30.0 0.75 1.00 1.50 1.0 1.5 2.0 8
8 8
241 238.5 237 2.5689697 2.578168641 2.583719695 33.71 38.80 51.00 0.00 0.00 0.00 0.00 0.00 0.00 5.42 5.45 5.46 11.97 11.33 10.96 11.97 11.33 10.96 11.97 11.33 10.96 0.000 0.000 0.000 0
0 0
0.000 0.000 0.000 0.000 0.000 0.000 120.0 2.00 4.0 8
233.5 2.596765584 63.74 0.00 0.00 5.50 10,15 10,15 10.15 0,000 0
0.000 0.000 120.0 4.00 6.0 8
228 2.617534573 112.64 0.00 0.00 5.55 8.97 8,97 8.97 0.000 0
0.000 0.00 120.0 6.00 8.0 8
220.5 2.646397224 158.29 0.00 0.00 5.63 7.56 7.56 7,56 0.000 0
0.000 0.000 120.0 8,00 10.0 8
213 2.675903489 200.45 0.00 111 0.0 5.71 6.35 6.35 6.35 0.000 0
0.000 0 000 120.0 10.00 12.0 8
208 2.695942606 236.95 0.00 0.00 5.77 5.64 5.64 5.64 0.000 0
0,000 0.000 120.0 12.00 14.0 8
203 2.716284123 267.20 0.00 267.20 5.82 5.00
-224.45 0.00 D =00 D
0.000 0.000 120.0 14.00 16,0 8
198 2.736934937 292.74 0.00 292.74 5.88 4.42
-215.82 0.00 0.000 0
0.000 0.000 240.0 16.00 20.0 8
193 2.757902156 314.53 0.00 314.53 5.94 3.91
-203.00 0.00 0.000 0
0.000 0.000 240.0 20.00 24.0 8
187.5 2.781340297 351.07 0.00 351.07 6.01 3.40
-195.36 0.00 0.000 0
0.000 0.000 720.0 24.00 36.0 8
180 2.813950943 381.90 0.00 381.90 6.10 2.80
-172.66 0.00 0.000 0
0.000 0.000 720.0 36.00 48.0 8
170.5 2,85637209 453.44 0.00 453,44 6.23 2.18
-156.60 0.00 0.005 0
0.000 0 000 1440.0 48.00 72.0 8
162 2.895426834 503.81 0.00 503.81 6.35 1.73
-135.65 0.
0 -0.000 0
0,000 0.000 2880.0 72.00 120.0 8
158 2.914177473 574.30 0.00 574.30 6.40 1.55
-137.34 0.00 0.000 0
0.000 0.000 3240.0 120.00 174.00 240.00 174.0 240.0 360.0 8
8 8
153 143.85 136.85 2.937960076 2.982502651 3.017501509 683.69 773.80 843.49 0.00 0.00 0.00 683.69 773,80 843.49 6.48 6.62 6.73 1.34 1.03 0.84
-140.64
-119.78
-104.42 0.00 0.00 0.00 0.000 0.000 0.000 0
0 0
0.000 0.000 0,000 0.000 0.000 0.000 M
360.00 480.0 8
132.15 3.04146531 929.29 0,00 929.29 6.81 0.73
-98.74 0.00 0.000 0
0.000 0.000 72 480.00 600.0 8
126.25 3.072091753 994.37 0.00 994.37 6.91 0.61
-86,87 0.00 0,000 0
0.000 0,000 600.00 720.0 8
121.1 3.099333643 1042.31 0.00 1042.31 7.00 0.52
-76.50 0.00 0.000 0
0.000 0,000
Entergy Attachment I Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 117 of 492 Interval Start of End of osi rve release Amount Duration Interval Interval Ave Ave Temp Si this Mat rate interval pred above interval kg Si Integral kg Constants Value min hrs hrs Interval H
1000/T Kl Si All Mat Only Si (ppm)
K k
R m g/kg release k
start Mass released Si released Mass Material (kg )
0 0.2 0,00 0.01 9.32 239 2,576323586 0
0 0.00 32.60 104.62 104.62 104.62 0,000 0
0 000 0 0000 Mass Element k) 0 0.2 0.01 0.0 9.32 255 2,518644969 0.05 0.00 0.00 38.43 139.64 139.64 139.64 0,000 0
0.000 0 000 a
.3.262764542 0.5 0.01 0.0 9.32 264 2.487321569 0.11 0.00 0.00 42.03 163.35 163.35 163.35 0.000 0
0 000 0 000 to 0.155049444 0.5 0.02 0.0 9.32 270 2.466868584 0.34 0.00 0.00 44.56 180.96 180.96 180.96 0.000 0
0 000 0 000 C
-1.240000065 3.5 0.03 0.1 9,32 274.5 2.451748233 0,60 0.00 0.00 46.52 195.19 195.19 195.19 0.000 0
0 000 0 000 I d 6.07665 5.0 0.08 0.2 9.32 276 2.446749222 2.59 0.00 0.00 47.19 200.14 200.14 200.14 0.000 0
0.000 0 000 e
0.16569 5.0 0.17 0.3 9.32 27 2.456767713 5.49 0.00 0.00 45.86 190.35 190.35 190.35 0.000 0
0 000 0 000 f
-2.17413 5.0 0.25 0.3 8.66 26.
2.468560144 8.21 0.00 0.00 35.03 139.49 339.49 139.49 0.000 0
0 000 0 000 5.0 0.33 0.4 8
264.5 2.485604209 10.33 0.00 0.00 26.36 99.57 99.57 99.57 0.000 0
0 000 0 000 5.0 0.42 0.5 8
258 2.508116544 11.96 0.00 0.00 24.72 88.96 88.96 88.96 0.000 0
0 000 0 000 15.0 0.50 0.8 8
249 2.539969238 13.39 0,00 0.00 22.57 75.85 75.85 75.85 0.000 0
0.OOD 0 000 15.0 0.75 1.0 8
241 2.5689697 16.96 0.00 0.00 20,78 65,60 65.60 65.60 0.000 0
0.000 0 000 30.0 1.00 1.5 8
238.5 2.578168641 19.96 0.00 0.00 20.24 62.65 62.65 62.65 0.000 0
0.000 0 000 30.0 1.50 2.0 8
237 2.583719695 25.58 0.00 0.00 19.92 60.93 60.93 60.93 0.000 0
0.000 0 000 120.0 2,00 4,0 8
233.5 2.596765584 30.91 O.OD O.O0 19.19 57.08 57.08 57,08 0.000 0
0 000 0 000 120.0 4.00 6,0 8
228 2.617534573 50.27 0.00 0.00 18.09 51.44 51.44 51.44 0.000 0
0 000 0 000 120.0 6.00 8.0 8
220.5 2.646397224 65.96 0.00 0.00 16.66 44.52 44.52 44.52 0.000 0
0.000 0 000 120.0 8.00 10.0 8
213 2.675903489 78.06 0.00 0.00 15.31 38.41 38.41 38.41 0.000 0
0.000 0 000 120.0 10.00 12.0 8
208 2.695942606 87.36 0.00 0.00 14.4 34.74 34.74 34.74 0.000 0
0.000 0 000 120.0 12.00 14.0 8
203 2.716284123 94.99 0.00 94.99 13.64 31.38
-187.06 0.00 0.000 0
0.000 0 000 120.0 14.00 16.0 8
198 2.736934937 97.44 0.00 97.44 12.86 28.30
-186.04 0.00 0.000 0
0.000 0 000 240.0 16.00 20.0 8
193 2.757902156 99.68 0.00 99.68 12.12 25,48
-184.12 0.00 0.000 0
0.000 0 000 240.0 20.00 24.0 8
187.5 2.781340297 103.78 0.00 1008 11.33 22.66
-184.83 0.00 0.000 0
0.000 0.000 720.0 24.00 36.0 8
180 2.813950943 107.45 0.00 107.45 10.32 19.24
-181.04 0.00 0,000 0
0.000 0.000 720.0 36.00 48.0 8
170.5 2.85637209 117.06 0.00 117.06 9.15 15.56
-183.59 0.00 0.000 0
0.000 0 000 1440.0 48.00 72.0 8
162 2.895426834 124.85 0.00 124.85 8.18 12.80
-182.49 0.00 0.000 0
0.000 0,000 2880.0 72.00 120.0 8
158 2.914177473 137.84 0.00 137.84 7.75 11.65
-195.44 0.00 0.000 0
0.000 0.000 3240.0 120.00 174.0 8
153 2.937960076 160.35 0.00 160.35 7.25 10.34
-218.56 0.00 0,000 0
0.000 0 000 3960.0 174.00 240.0 8
143,85 2.982502651 180.69 0.00 180.69 6.38 8.28
-226.09 0.00 0.000 0
0.000 0 000 7200.0 240.00 360.0 8
136.85 3.017501509 199.85 0.00 199.85 5.77 6.95
-233.48 0.00 0.000 0
0.000 0 000 7200.0 360.00 480.0 8
132.15 3.04146531 220.73 0.00 220.73 5.39 6.16
-246.04 0.00 0.000 0
0.000 0 000 7200.0 480,00 600.0 8
126.25 3.072091753 220.73 0.00 220.73 4.94 5.28
-230.84 0.00 0000 0
0,000 0 000 7200.0 600.00 720.0 8
121.1 3,099333643 220.73 0.00 220.73 4.57 4.61
-218.07 0.00 0.000 0
0.000 0.000
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 118 of 492 Interval Start of End of Positive Amount Duration Interval Interval Ave Ave Temp Si this Mat release rate interval pred above interval kg Si Integral kg Si Constants Value (min) hrs)
(hrs Interval pH (F) 100017 (K )
Si Al Mat Only Si (ppm) k R
(mg/kg-min) release (kg) start Mass released released Mass Material (kg) 0 0.2 0.00 0.01 9,32 239 2.576323586 0
0 0,00 9.82 2151.89 2151.89 2151.89 0.000 0
0 000 0 000 Mass Element
( kg) 0 0.2 0.01 0.0 9.32 255 2.518644969 0.05 0.00 0.00 10.35 4611.93 4811.93 4811.93 0.000 0
0 000 0 000 a
0.974998166 0.5 0.01 0.0 9.32 264 2.487321569 0.11 0.00 0.00 10.65 7449.38 7449.38 7449.38 0.000 o
D DDD 0 000 b
0.111219937 0.5 0.02 0.0 9.32 270 2.466868584 0.34 0,00 0,00 10,85 9909.54 9909.54 9909.54 0,000 0
0 000 0 000 o
-0.395709671 3.5 0.03 0.1 9.32 274.5 2.451748233 0.60 0.00 0.00 11.00 12236.97 12236.97 12236.97 0.000 0
0 000 0 000 d
15.69692 5.0 0,08 0.2 9.32 276 2.446749222 2.59 0.00 0.00 11.05 13120.94 13120.94 13120.94 0.000 0
0 000 0 000 e
0.34838 5.0 0.17 0.3 9.32 273 2.456767713 5.49 0.00 0.00 10.95 11409.29 11409.29 11409.29 0.000 0
0 000 0 000 T
.6,05941 5.0 0.2 0.3 8.66 269.5 2.468560144 8.21 0,00 0,00 9,15 5699,97 5699.97 5699.97 0.000 0
0.000 0 000 5.0 0.33 0.4 8
264.5 2.485604209 10.33 0.00 0.00 7.61 2646.46 2646.46 2646.46 0.000 0
D.ooo 0 000 5,
0.42 0.5 8
258 2.508116544 11.96 0.00 0.00 7.45 1933.10 1
333.10 1933.10 0.000 0
0 000 0 000 15.0 0.50 0.8 8
249 2.539969238 13.39 0.00 0.00 7.24 1239.50 1239.50 1239.50 0.000 0
0.000 0.000 15.0 0.75 1.0 8
241 2.5689697 16.96 0,00 0,00 7.05 827.03 827.03 827.03 0,000 0
0 000 0 000 30.0 1.00 1.5 8
238.5 2.578168641 19.96 0.00 0.00 6.99 727.41 727,41 727.41 0.000 0
0.000 0.000 30.0 1.50 2.0 8
237 2.583719695 25.58 o.oD 0.00 11 6.96 673.20 673.20 673.20 0.000 0
0 000 0 000 120.0 2.00 4.0 8
233.5 2.596765584 30.91 0,0 0,0 6.87 561.17 561.17 561.17 0,000 0
0.000 0 000 120.0 4.00 6.0 8
228 2.617534573 50.27 0.00 0.00 6.74 420.00 420.00 420.00 0.000 0
0.000 0 000 120.0 6.00 8.0 8
220.5 2.646397224 65.96 0.00 0.00 6.57 280.77 280.77 280.77 0.000 0
0.000 0.000 120.0 8,00 10.0 8
213 2.675903489 78.06 o.05 0.00 6.40 186.02 186.02 186.02 0.000 D
0 000 0 000 120,0 10.00 1 12.0 8
208 2.695942606 87.36 0,00 0.00 6.28 140,65 140,65 140.65 0.000 0
0.000 0 000 120.0 12.00 F 14.0 8
203 2.716284123 94.99 0.00 94,99 6.16 105.90
-1525.89 0.00 0.000 0
0 000 0 000 120.0 14.00 16,0 8
198 2.736934937 97.44 0.00 97.44 6.05 79.39
-1199.29 0,00 0.000 0
0,000 0.000 240.0 16.00 20.0 8
193 2.757902156 99.68 0.00 99.68 5.94 59.25
-935.8 0.00 0.000 0
0 000 D DDO 240.0 20,00 24.0 8
187.5 2.781340297 103.78 0.00 103.78 5,81 42.72
-720.48 0.00 0.000 0
0.000 0 000 720.0 24.00 36.0 8
180 2.813950943 107.45 0.00 107.45 5.64 27.11
-489.37 0.00 0.000 0
0 000 0 000 720.0 36.00 48.0 8
170.5 2.85637209 117.06 0.00 117.06 5.43 15.00
-308.57 0.00 0.000 0
0.000 0 000 1440.0 48.00 72.0 8
162 2.895426834 124.85 0.00 124.85 5.24 8.70
-198,68 0.00 0.000 D
0.000 0 000 2880.0 72.00 120.0 8
158 2.914177473 137.84 0.00 137.84 5.15 6.70
-172.59 0.00 0.000 0
0.000 0 000 3240.0 120.00 174.0 8
153 2.937960076 160.35 0.00 160.35 5.04 4.80
-148.15 0.00 0.000 0
0.000 0 000 3960.0 174.00 240.0 8
143.85 2.982502651 160.69 0.00 180.69 4.8 2.58
-93.83 0.00 0.000 0
0.000 0.000 7200.0 240.00 360.0 8
136,85 3.017501509 199.85 0.00 199.65 4.68 1.58
-65.98 o.01) 0,000 0
0 000 0 000 7200.0 360.00 480.0 8
132.15 3.04146531 220.73 0.00 220.73 4.58 1.13
-53.46 0.00 D.uuu 0
0.000 6.000 720.0 480.00 600.0 8
126.25 3.072091753 220.73 0.00 220.73 4.46 0.74
-35.87 0.00 0.000 0
0.000 0 000 7200.0 600.00 720.0 8
121.1 3.099333643 220.73 0.00 220.73 4.35 0.51
-25.16
-- D 0.000 0
0.000
-0.000
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 119 of 492 Interval Start of End of pHa pHa /
corrosion rate Integral Duration Interval Interval Average 1000 /r Kelvin square (1000/
log (mg/m2-interval mg Al interval kg kg Al mass available min hrs hrs Interval H
Ave. T F
1 d
prediction min released Al released released Inte g ral k Al Model term coeff 0.2 0.00 0.0056 9.32 239 2.576323586 86.86 3.62 2.24666934 176.46937 87306 0.087 0
0.0873 Intercept 14 69039 0.2 0.01 0.01 9.32 255 2.518644969 86.86 3.70 2.41508581 260.06733 128665 0.1287 0
0.216 pHa 0
0.5 0.01 0.02 9.32 264 2.487321569 86.86 3.75 2.60461344 319.60491 474360 0.474 1
0.690 1000/T K-1
-4 64537 0.5 0.02 0.03 9.32 270 2.466868584 86.86 3.78 2.56230436 365.00966 541750 0.542 1
1.23 pHa squared 0 044554 3.5 0.03 0.08 9,32 274.5 2.451748233 86.86 3.80 2.60455341 341 40230313 4179706 4.180 5
5.41 pHaf(1000/T)
-1 20131 50 0.08 0.17 9.32 76 2.446749222 86.86 3.81 548 415.3799 6165095 6.165 12 11 577 5.0 0.17 25 9.32 273 2.456767713 86.86 3.79 26 389.55274 5781767 5.782 17 17 359 5.0 0.25 0.33 8.66 269.5 2.468560144 75.00 3.51 021 223.88769 3322956 3.323 21 20 682 5.0 0.33 0.42 8
264.5 2.485604209 64.00 3.22 V
04 134.53617 1996794 1.997 23 22 678 5.0 0.42 0.50 8
258 2.508116544 64.00 3.19 551 114.5422 1700043 1.700 24 24 378 15.0 0,50 0.75 8
24 2.539969238 00 3,15 046 10019 4051968 4052 28 28 430 15,0 0.75 1.00 8
241 2.5689697 64,00 3.11 593 73,628496 3278397 3.278 32 31709 30.0 1.00 1.50 236.5 2.578168641 64.00 3.10
.136 68.811554 6127833 6.128 38 37 837 30.0 1.50 2.00 8
237 2.583719695 64.00 3.10 1.81988342 66.051611 5882054 5.882 44 43 719 120.0 2.00 4.00 8
233.5 2.596765584 64.00 3.08 1.77796752 59.974622 21363533 21.364 65 65 082 120.0 4.00 6.00 8
228 2.617534573 64.00 3.06 1.71085331 51.387005 18304542 18.305 83 83 387 120.0 6.00 8.00 8
220.5 2.646397224 64.00 3.02 1.61681938 41.382753 14740932 14.741 98 98 128 120.0 8,00 10,00 8
213 2.675903489 64,00 2.99 1.51979563 33.097533 11789658 11.790 110 109 917 120.0 10.00 12.00 8
208 2.695942606 64.00 2.97 1.45340236 28.405495 10118309 10.118 120 120 036 120.0 12.00 14.00 8
203 2.716284123 64.00 2.95 1.38560433 24.299892 8655853 8.656 129 128 692 120.0 14.00 16.00 8
198 2.736934937 64.00 2.92 1.31636951 20.719034 7380318 7.380 136 136 072 240.0 16.00 20,00 8
193 2.757902156 64,00 2.90 1.24566487 17.606169 12542971 12.543 149 148 615 240.0 20.00 24.00 8
187.5 2.781340297 64.00 2.88 1.16615147 14.660591 10444485 10.444 159 159 059 720.0 24.00 36.00 8
180 2.813950943 64,00 2.84 1.05470673 11.342446 24241726 24.242 183 183 301 720.0 36,00 48,00 8
170.5 2,85637209 64.00 2.80 0,90836693 8.0977978 17307078 17.307 201 200 606 1440.0 48.00 72.00 8
162 2.895426834 64,00 2.76 0,77232615 5.9200606 25305386 25.305 226 225 913 2880.0 72.00 120.00 8
158 2.914177473 64.00 2.75 0.70657918 5.0883758 43500674 43.501 269 269 414 3240.0 120.00 174.00 8
153 2.937960076 64.00 2.72 0.62279605 4.1956191 40352029 40.352 310 309 766 396,0 174,00 240.00 8
143,85 2.982502651 64.00 2.68 0.46473274 2.9156322 34273009 34.273 344 344 039 720.0 240.00 360.00 8
136.85 3.017501509 64.00 2.65 0.3395243 2.1853666 46706908 46.707 391 390 746 7200.0 360.00 480.00 132.5 1
3.04146531 64.00 2.63 0.25329769 1.7918337 38296096 38.296 429 429 042 7200.0 480.00 600,00 126.25 3.072091753 64.00 2.60 0.14252766 1.3884417 29674572 29.675 459 458 717 7200.0 600.00 720.00 6
121.1 3.099333643 64.00 2.58 0.04347574 1.1052887 23622864 23.62 482 482.340
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 120 of 492 Elap Time 0.11 Interval Startof End of Average Average pHa
- ed Duration Interval Interval Interval Temperature square pHa/(1000/
^
^
corrosion rate interval mg Al interval Kg Integral kg mass available (min)
(min )
(hrs )
(hrs) p H F
1000/1 (K' d
T) log prediction (m /m2-min )
released Al released Al released Integral kg Al Model term Value
.66667 0. 167 0,00 0,01 5, 1 280, 5 2.431873759 26,01 2. 10 2.032967759 107.8866627 181659 0
0,182 0,1817 Intercept 14 69039 0
0.167 0, 01 0,01 5. 1 280 2.43351765 26.01 2. 10 2.027033138 106,422422 179193 0, 179 0.361 0, 361 pHa 0
t 0,500 0, 01 0,02 5.1 277,5 2,441770555 26,01 2.09 1.997204648 99.35841343 501897 0.502 0,863 0. 863 1000/1 (K-1)
-4 645366 1
0.500 0, 02 0,03 5. 1 274 2.453419112 26. 01 2.08 1,955005821 90.15832222 455424 0,455 1,318 1.318 pHa squared 0 044554 2
3,5 0,03 0,08 5.1 268.5 2.471950231 26.01 2.06 1.887642394 77.20446081 2729921 2,730 4, 048 4,048 pHa/(1000/T)
-1 20131 5
10 5.0 5 0 0,08 D t7 0.17 0 25 5.1 5 1 260 25 2.501146359 5
26.01 2.04 1.780947231 60.38752508 3050401 3. 050 7. 098 7.098 0
- 2. 36390153 26,01 2. 01 1,651264005 44.79855492 2262943 2.263 9,361 9 361 15 5,0 0.25 0.33 6.55 242,5 2.563481778 42,90 2. 56 1.624061556 42.0 8862659 2125549 2.126 11,487 11 487 20 5,0 0, 33 0,42 8
230 2.609943886 64.00 3,07 1.735436522 54.37966427 2746921 2,747 14,234 14 234 25 5.0 0.42 0,50 8
217. 5 2.658121299 64.00 3,01 1.578374222 37.87688205 1913304 1.913 16,147 16 147 30 15. 0 0,50 0, 75 8
206,5 2.702013 64.00 2, 96 1.433211892 27.11514253 4109063 4.109 20 256 20 256 45 15.0 1,75 1,00 8
207 2.6999865 64.00 2, 96 1.439956147 27.53950611 4173372 4,173 24.430 24 430 60 30, 0 1,00 1, 50 8
218,5 2,654201749 64,00 3.01 1.591242813 39.01600634 11825070 11,825 36, 255 36 255 90 30. 0 1.50 2.00 8
221. 5 2.642512148 64.00 3,03 1.629527827 42.61159856 12914831 12.915 49.170 0
49 170 120 120.0 2. 00 4,00 8
221 2.644453259 64.00 3. 03 1.623180232 41.99332201 50909768 50. 910 100,07 100 079 240 120,0 4,00 6.00 8
220 2,648344049 64,00 3,02 1.610445242 40.77981409 49438596 49.439 149,518 149 518 360 120.0 6. 00 8.00 8
219 2.652246305 64.00 3.02 1. 597656988 39.59651714 48004050 48.004 197, 522 197.522 480 120,0 8, 00 10,00 8
215 2.667971008 64.00 3,00 1 7545966601 35,15334048 42617453 42.617 240.139 240 139 600 120.0 10.00 12.00 8
208.5 2.693925199 64.00 2. 97 1.460104381 28.84724753 34972387 34,972 275. 112 275 112 720 120.0 12.00 14, 00 8
203 2,716284123 64, 00 2,95 1.385604335 24.29989153 29459490 29.459 304. 571 304 571 840 120,0 14. 00 16. 00 8
198 2.736934937 64.00 2.92 1.316369513 20.71903446 25118309 25. 118 329.690 329 690 960 240, 0 16,00 20.00 8
192,5 2. 76001656 64.00 2090 1.238512267 17.31857949 41991671 41.992 371. 681 371 681 1200 240.0 20.00 24.00 8
187. 5 2.781340297 64.00 2.88 1.16615147 14.66059074 35546951 35,547 407.228 407 228 1440 720. 0 24,00 36.00 8
180 2, 813950943 64.00 2.84 1.05470673 11.34244624 82504734 82.505 489.733 489 733 2160 720. 0 36,00 48,00 8
170 2.85864024 64,00 2.80 0.90050012 7.952434858 57845857 57.846 547.579 547 579 2880 1440.0 48.00 72. 00 8
160 2.904771895 64.00 2.75 0.73959323 5,490264025 79872148 79,872 627.451 627 451 4320 2880,0 72.00 120. 00 8
152,5 2,940359704 64.00 2.72 0.614318478 4.114513368 119715562 119.716 747.167 747 167 7200 3240,0 120, 00 174.00 8
143.5 2. 984233301 64.00 2.68 0.458561939 2.874497526 94090677 94.091 841.257 841 257 10440 3960.0 174,00 240,00 8
131.5 3.044809446 64.00 2, 63 0.241233409 1.742743249 69721743 69,722 910 979 910 979 14400 7200. 0 240,00 0,00 8
121,35 3.098000069 64.00 2, 58 0,048335897 1.1177274 81303274 11.303 992.282 992 282 21600 7200, 0 360, 00 48 480, 00 8
114225 3.136462245 64,00 2,55
-0, 09229352 0.808549245 58813715 58,814 1051,096 1051 096 28800 7200, 0 480,00 600, 00 8
106,975 3, 176592046 64.00 2.52
-0.24000228 0.575436914 41857170 41.857 1052.953 1092 953 36000 7200, 0 600.00 720. 00 8
101.6 3207012668 64.00 2.49
-0,35261926 0.443997723 32296308 32.296 1125.249 1125.249
Entergy Document No. 2007-03464 Palisades Nuclear Power Plant Revision 0 Project No. 12122-005 Page 121 of 492 Submerged Not-Submerged Total Al Min Time (hrs) (thick)
(thin)
Release 0.33 0.006 0.087306 0.1817 0.2690 0.50 0.0 0.2 0.36 0.58 1.00 0.0 0.7 0.86 1.55 1.50 0.0 1.2 1.32 2.55 5.00 0.1 5.4 4.05 9.46 10.00 0.2 11.6 7.10 18.68 15.00 0.3 17.4 9.36 26.72 20.00 0.3 20.7 11.49 32.17 25.00 0.4 22.7 14.23 36.91 30.00 0.5 24.4 16.15 40.53 45.00 0.8 28.4 20.26 48.69 60.00 1.0 31.7 24.43 56.14 90.00 1.5 37.8 36.25 74.09 120.00 2.0 43.7 49.17 92.89 240.00 4.0 65.1 100.08 165.16 360.00 6.0 83.4 149.52 232.90 480.00 8.0 98.1 197.52 295.65 600.00 10.0 109.9 240.14 350.06 720.00 12.0 120.0 275.11 395.15 840.00 14.0 128.7 304.57 433.26 960.00 16.0 136.1 329.69 465.76 1200.00 20.0 148.6 371.68 520.30 1440.00 24.0 159.1 407.23 566.29 2160.00 36.0 183.3 489.73 673.03 2880.00 48.0 200.6 547.58 748.19 4320.00 72.0 225.9 627.45 853.36 7200.00 120.0 269.4 747.17 1016.58 10440.00 174.0 309.8 841.26 1151.02 14400.00 240.0 344.0 910.98 1255.02 21600.00 360.0 390.7 992.28 1383.03 28800.00 480.0 429.0 1051.10 1480.14 36000.00 600.0 458.7 1092.95 1551.67 43200.00 720.0 482.3 1125.25 1607.59 Aluminum Release 1800.000000 1600.000000 1400.000000 1200.000000 N
1000.000000 a
w 800.000000 a
600.000000 400.000000 200.000000 0.000000 Submerged (thick)
- Not-Submerged (thin)
Total Al Release 0.000 10.000 20.000 30.000 40.000 50.000 Time (hrs)
Entergy Palisades Nuclear Power Plant Project No. 12122-005 Aluminum Metal Submerged 0.000 0.000 482.340 Aluminum Metal Not-Submerged 0.000 0.000 1,125.249 Concrete 42.758 1.424 0.459 E-glass (Fiberglass, Nukon) 13.828 84.986 3.072 Calcium Silicate (Cal-Sil, Marinite) 233.610 242.929 0.000 TOTAL Released Material 290.195 329.340 1,611.119 Concentration in the sump (mg/kg (mass dissolved divided by the sump pool mass) 194.492 220.728 1,079.792 Document No. 2007-03464 Revision 0 Page 122 of 492 Si as SiO2 MW Si 28.086 MW Si02 60.085 704.564 kg 472.207 mg/kg
Entergy Palisades Nuclear Power Plant Project No. 12122-005 Source of Material Release Mass of Precipitate (kg)
Ca3(PO4)2 NaAISiO$
AIOOH Total Aluminum Metal Submerged 0.000 153.320 1,000.750 1,154.070 Aluminum Metal Not-Submerged 0.000 357. 681 2,334.648 2,692.329 Concrete 0.000 2.360 0.952 3.312 E-glass (Fiberglass, Nukon )
0.000 133.130 6.373 139.503 Calcium Silicate ( Cal-Sil, Marinite )
0.000 377.755 0.000 377.755 TOTAL Precipitate 0.000 1,024.247 3,342.722 1 4,366.969 Document No. 2007-03464 Revision 0 Page 123 of 492
Entergy Palisades Nuclear Power Plant Project No. 12122-005 Density of aluminum square feet to square cm cm to mils 2.6989 g/cm3 929.03 cm2/ft2 393.70 mil/cm Attachment I Area - submerged 31,952 ft2 Area - submerged 29,684,088 cm2 Aluminum dissolved 482,340 grams Aluminum dissolved 178,717 cm3 Reduction in thickness 0.0060 cm Reduction in thickness 2.3703 mils Corrosion rate 28.8390 mils/year Original mass of aluminum 1,634 pounds 741 kg Fraction of mass dissolved 65.1% 1 Area - not submerged 108,745 ft2 Area - not submerged 101,027,367 cm2 Aluminum dissolved 1,125,249 grams Aluminum dissolved 416,929 cm3 Reduction in thickness 0.0041 cm Reduction in thickness 1.6248 mils Corrosion rate 19.7679 mils/year Original mass of aluminum 5,756 pounds 2,611 kg Fraction of mass dissolved 43.1 Document No. 2007-03464 Revision 0 Page 124 of 492
Entergy Palisades Nuclear Power Plant Project No. 12122-005 Si (g)
Si (ppm)
Si02 (g)
Si02 (ppm) 329,340 221 704,564 472 Document No. 2007-03464 Revision 0 Page 125 of 492
ENCLOSURE 2 LICENSE AMENDMENT REQUEST:
CONTAINMENT SUMP BUFFERING AGENT AND WEIGHT REQUIREMENTS OPERATING LICENSE PAGE CHANGE INSTRUCTIONS and REVISED TECHNICAL SPECIFICATIONS TABLE OF CONTENTS PAGE ii and REVISED TECHNICAL SPECIFICATIONS PAGE 3.5.5-1 3 Pages Follow
ATTACHMENT TO LICENS E AMEN DMENT NO.
FACILITY OPERATING LICENSE NO. D PR-20 DOCKET NO. 50-255 Remove the following page of Appendix A Technical Specifications and replace with the attached revised page. The revised page is identified by amendment number and contains marginal lines indicating the areas of change.
REMOVE INSERT Table of Contents page ii Table of Contents page ii 3.5.5-1 3.5.5-1
TABLE OF CONTENTS 3.4 PRIMARY COOLANT SYSTEM (PCS)
TECHNICAL SPECIFICATIONS 3.4.1 PCS Pressure, Temperature, and Flow Departure from Nucleate Boiling (DNB) Limits 3.4.2 PCS Minimum Temperature for Criticality 3.4.3 PCS Pressure and Temperature (P/T) Limits 3.4.4 PCS Loops - MODES 1 and 2 3.4.5 PCS Loops - MODE 3 3.4.6 PCS Loops - MODE 4 3.4.7 PCS Loops - MODE 5, Loops Filled 3.4.8 PCS Loops - MODE 5, Loops Not Filled 3.4.9 Pressurizer 3.4.10 Pressurizer Safety Valves 3.4.11 Pressurizer Power Operated Relief Valves (PORVs) 3.4.12 Low Temperature Overpressure Protection (LTOP) System 3.4.13 PCS Operational LEAKAGE 3.4.14 PCS Pressure Isolation Valve (PIV) Leakage 3.4.15 PCS Leakage Detection Instrumentation 3.4.16 PCS Specific Activity 3.4.17 Steam Generator (SG) Tube Integrity 3.5 EMERGENCY CORE COOLING SYSTEMS (ECCS) 3.5.1 Safety Injection Tanks (SITs) 3.5.2 ECCS - Operating 3.5.3 ECCS - Shutdown 3.5.4 Safety Injection Refueling Water Tank (SIRWT) 3.5.5 Containment Sump Buffering Agent and Weight Requirements 3.6 CONTAINMENT SYSTEMS 3.6.1 Containment 3.6.2 Containment Air Locks 3.6.3 Containment Isolation Valves 3.6.4 Containment Pressure 3.6.5 Containment Air Temperature 3.6.6 Containment Cooling Systems 3.7 PLANT SYSTEMS 3.7.1 Main Steam Safety Valves (MSSVs) 3.7.2 Main Steam Isolation Valves (MSIVs) 3.7.3 Main Feedwater Regulating Valves ( MFRVs) and MFRV Bypass Valves 3.7.4 Atmospheric Dump Valves (ADVs) 3.7.5 Auxiliary Feedwater (AFW) System 3.7.6 Condensate Storage and Supply 3.7.7 Component Cooling Water (CCW) System 3.7.8 Service Water System (SWS) 3.7.9 Ultimate Heat Sink (UHS) 3.7.10 Control Room Ventilation (CRV) Filtration 3.7.11 Control Room Ventilation (CRV) Cooling 3.7.12 Fuel Handling Area Ventilation System 3.7.1.3 Engineered Safeguards Room Ventilation (ESRV ) Dampers 3.7.14 Spent Fuel Pool (SFP ) Water Level 3.7.15 Spent Fuel Pool (SFP) Boron Concentration 3.7.16 Spent Fuel Assembly Storage 3.7.17 Secondary Specific Activity Palisades Nuclear Plant ii Amendment No. 4-99,2-24,22-3
STB 3.5.5 3.5 EMERGENCY CORE COOLING SYSTEMS (ECCS) 3.5.5 Containment Sump Buffering Agent and Weight Requirements LCO 3.5.5 Buffer baskets shall contain >_ 8,186 lbs and :510,553 lbs of Sodium Tetraborate Decahydrate (STB) Na2B4O7' 10H20.
APPLICABILITY:
MODES 1, 2, and 3.
ACTIONS COMPLETION CONDITION REQUIRED ACTION TIME A.
STB not within limits.
A.1 Restore STB to within limits.
72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> B.
Required Action and B.1 Be in MODE 3.
6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time not met.
AND B.2 Be in MODE 4.
30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br /> SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.5.5.1 Verify the STB baskets contain >_ 8,186 lbs and 18 months
<10,553 lbs of equivalent weight sodium tetraborate decahydrate.
SR 3.5.5.2 Verify that a sample from the STB baskets provides 18 months adequate pH adjustment of borated water.
Palisades Nuclear Plant 3.5.5-1 Amendment No. 4
ENCLOSURE 3 LICENSE AM EN DMENT REQUEST:
CONTAINM ENT SUMP BUFFERIN G AGENT AND WEIGHT REQUIREMENTS 2 Pages Follow
TABLE OE CONTENTS TECHNICAL SPECIFICATIONS 3.4 PRIMARY COOLANT SYSTEM (PCS) 3.4.1 PCS Pressure, Temperature, and Flow Departure from Nucleate Boiling (DINB) Limits 3.4.2 PCS Minimum Temperature for Criticality 3.4.3 PCS Pressure and Temperature (P/T) Limits 3.4.4 PCS Loops - MODES 1 and 2 3.4.5 PCS Loops - MODE 3 3.4.6 PCS Loops - MODE 4 3.4.7 PCS Loops - MODE 5, Loops Filled 3.4.8 PCS Loops - MODE 5, Loops Not Filled 3.4.9 Pressurizer 3.4.10 Pressurizer Safety Valves 3.4.11 Pressurizer Power Operated Relief Valves (PORVs) 3.4.12 Low Temperature Overpressure Protection (LTOP) System 3.4.13 PCS Operational LEAKAGE 3.4.14 PCS Pressure Isolation Valve (PIV) Leakage 3.4.15 PCS Leakage Detection Instrumentation 3.4.16 PCS Specific Activity 3.4.17 Steam Generator (SG) Tube Integrity 3.5 EMERGENCY CORE COOLING SYSTEMS (ECCS) 3.5.1 Safety Injection Tanks (SITs) 3.5.2 ECCS - Operating 3.5.3 ECCS - Shutdown 3.5.4 Safety Injection Refueling Water Tank (SIRWT) 3.5.5
-Containment Sump Buffering Agent and Weight Requirements 3.6 CONTAINMENT SYSTEMS 3.6.1 Containment 3.6.2 Containment Air Locks 3.6.3 Containment Isolation Valves 3.6.4 Containment Pressure 3.6.5 Containment Air Temperature 3.6.6 Containment Cooling Systems 3.7 PLAINT SYSTEMS 3.7.1 Main Steam Safety Valves (MSSVs) 3.7.2 Main Steam Isolation Valves (MSIVs) 3.7.3 Main Feedwater Regulating Valves (MFRVs) and MFRV Bypass Valves 3.7.4 Atmospheric Dump Valves (ADVs) 3.7.5 Auxiliary Feedwater (AFW) System 3.7.6 Condensate Storage and Supply 3.7.7 Component Cooling Water (CCW) System 3.7.8 Service Water System (SWS) 3.7.9 Ultimate Heat Sink (UHS) 3.7.10 Control Room Ventilation (CRV) Filtration 3.7.11 Control Room Ventilation (CRV) Cooling 3.7.12 Fuel Handling Area Ventilation System 3.7.13 Engineered Safeguards Room Ventilation (ESRV) Dampers 3.7.14 Spent Fuel Pool (SFP) Water Level Palisades Nuclear Plant ii Amendment No.9, 21-, ^
TABLE OF CONTENTS TECHNICAL SPECIFICATIONS 3.7.15 Spent Fuel Pool (SFP) Boron Concentration 3.7.16 Spent Fuel Assembly Storage 3.7.17 Secondary Specific Activity Palisades Nuclear Plant ii Amendment No. 48-9,2-24,2-2-3
ACTIONS COMPLETION CONDITION REQUIRED ACTION TIME A.
T STB not within limits.
I A.1 Restore T&FLSTB to within I
72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> limits.
B.
Required Action and B.1 Be in MODE 3.
6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time not met.
AND B.2 Be in MODE 4.
30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br /> SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.5.5.1 Verify the T STB baskets contain 0-8,186 18 months lbs and <_ 447099-_10,_553 lbs of equivalent wei g ht sodium tetraborate decahydrate.
SR 3.5.5.2 Verify that a sample from the STB baskets 18 months provides adequate pH adjustment of borated water.
Palisades Nuclear Plant 3.5.5-1 Amendment No. 48-9