ML050140372

From kanterella
Jump to navigation Jump to search

Technical Specifications, Elimination of Requirements for Hydrogen Recombiners and Hydrogen Monitors (MC1903)
ML050140372
Person / Time
Site: Palisades Entergy icon.png
Issue date: 01/11/2005
From:
NRC/NRR/DLPM
To:
Jaffe D, NRR/DLPM, 415-1439
Shared Package
ML050140208 List:
References
TAC MC1903
Download: ML050140372 (3)


Text

PAM Instrumentation 3.3.7 3.3 INSTRUMENTATION 3.3.7 Post Accident Monitoring (PAM) Instrumentation LCO 3.3.7 The PAM instrumentation for each Function in Table 3.3.7-1 shall be OPERABLE.

APPLICABILITY: MODES 1, 2, and 3.

ACTIONS


NOTE------

Separate Condition entry is allowed for each Function.

CONDITION REQUIRED ACTION COMPLETION TIME A. One or more Functions A.1 Restore required 30 days with one required channel channel to OPERABLE inoperable. status.

B. Required Action and B.1 Initiate action in Immediately associated Completion accordance with Time of Condition A not Specification 5.6.6.

met.

C. One or more Functions C.1 Restore one channel to 7 days with two required channels OPERABLE status.

inoperable.

Palisades Nuclear Plant 3.3.7-1 Amendment No. +69, -9,221

PAM Instrumentation 3.3.7 ACTIONS CONDITION l REQUIRED ACTION l COMPLETION TIME D. (Not used)

E. Required Action and E.1 Enter the Condition Immediately associated Completion referenced in Time of Condition C etD Table 3.3.7-1 for the not met. channel.

F. As required by Required F.1 Be in MODE 3. 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> Action E.1 and referenced in Table 3.3.7-1. AND F.2 Be in MODE 4. 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br /> G. As required by Required G.1 Initiate action in Immediately Action E.1 and referenced accordance with in Table 3.3.7-1. Specification 5.6.6.

Palisades Nuclear Plant 3.3.7-2 Amendment No. 4-B9, 221

PAM Instrumentation 3.3.7 Table 3.3.7-1 (page 1 of 1)

Post Accident Monitoring Instrumentation CONDITIONS REFERENCED REQUIRED FROM REQUIRED FUNCTION CHANNELS ACTION E.1

1. Primary Coolant System Hot Leg Temperature (wide range) 2
2. Primary Coolant System Cold Leg 2 Temperature (wide range)
3. Wide Range Neutron Flux 2
4. Containment Floor Water Level 2 (wide range)
5. Subcooled Margin Monitor 2
6. Pressurizer Level (wide range) 2
7. (Deleted)
8. Condensate Storage Tank Level 2
9. Primary Coolant System Pressure 2 (wide range)
10. Containment Pressure (wide range) 2
11. Steam Generator A Water Level 2 (wide range)
12. Steam Generator B Water Level 2 (wide range)
13. Steam Generator A Pressure 2
14. Steam Generator B Pressure 2
15. Containment Isolation Valve Position 1 per valve (a
16. Core Exit Temperature - Quadrant 1 4
17. Core Exit Temperature - Quadrant 2 4
18. Core Exit Temperature - Quadrant 3 4
19. Core Exit Temperature - Quadrant 4 4
20. Reactor Vessel Water Level 2
21. Containment Area Radiation 2 G (hiqh range)

(a)Not required for isolation valves whose associated penetration is isolated by at least one closed and de-activated automatic valve, closed manual valve, blind flange, or check valve with flow through the valve secured.

Palisades Nuclear Plant 3.3.7-4 Amendment No. +89, 221