Cycle 17, Revision 25 Core Operating Limits Report (COLR)
ML050880447
Person / Time
Site: Mcguire
(NPF-017)
Issue date: 03/16/2005
From: Gordon Peterson
Duke Power Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
MCEI-0400-47, Rev 25
Download: ML050880447 (35)


Text

_ Duke OrPowere A Duke Energy Company GARY R. PETERSON Vice President McGuire Nuclear Station Duke Power MGOI VP / 12700 Hagers Ferry Road Huntersville, NC 28078-9340 704 875 5333 704 875 4809 fax grpeters@duke-energy.com March 16, 2005 U. S. Nuclear Regulatory Commission Document Control Desk Washington, D.C. 20555

Subject:

McGuire Nuclear Station, Docket Nos. 50-370 Unit 2, Cycle 17, Revision 25 Core Operating Limits Report (COLR)

Pursuant to McGuire Technical Specification 5.6.5.d, please find enclosed Revision 25 to the McGuire Unit 2 Cycle 17 Core Operating Limits Report (COLR).

Questions regarding this submittal should be directed to Kay Crane, McGuire Regulatory Compliance at (704) 875-4306.

Gary R. Peterson Attachment www.duke-energy.com r n

U. S. Nuclear Regulatory Commission March 16, 2005 Page 2 cc:

Mr. J. J. Shea, Project Manager U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Washington, D.C. 20555 Mr. W. D. Travers, Regional Administrator U. S. Nuclear Regulatory Commission, Region II Atlanta Federal Center 61 Forsyth St., SW, Suite 23T85 Atlanta, GA 30323 Mr. Joe Brady Senior Resident Inspector McGuire Nuclear Station

MCEI-0400-47 Page I of 33 Revision 25 McGuire Unit 2 Cycle 17 Core Operating Limits Report Revision 25 February 2005 Calculation Number MCC-1553.05-00-0418 (Rev. 0)

Duke Power Company Date Prepared By:

Checked By:

(Secti s 2.2 10- 2.17) '

Pdi fu 2 12h$cI ZZZo<

4// I Checked By:

Approved By:

QA Condition 1 The information presented in this report has been prepared and issued in accordance with McGuire Technical Specification 5.6.5.

MCE1.0400-47 Page 2 of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report INSPECTION OF ENGINEERING INSTRUCTIONS Inspection Waived By:

(Sponso)

IP. 0 Date: 3 t0-;L oc CATAWBA MCE (Mechanical & Civil)

RES (Electrical Only)

RES (Reactor)

MOD Other(

)

Inspection Waived El El El El El Inspected By/Date:

Inspected By/Date:

Inspected By/Date:

Inspected By/Date:

Inspected By/Date:

OCONEE MCE (Mechanical & Civil)

RES (Electrical Only)

RES (Reactor)

MOD Other(

)

Inspection Waived El El El El El Inspected By/Date:

Inspected By/Date:

Inspected By/Date:

Inspected By/Date:

Inspected By/Date:

MCGUIRE MCE (Mechanical & Civil)

RES (Electrical Only)

RES (Reactor)

MOD Other (

Inspection Waived Gfr Ely ID-(LI Inspected By/Date:

Inspected By/Date:

Inspected By/Date:

Inspected By/Date:

Inspected By/Date:

MCEI-040047 Page 3 of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report Implementation Instructions For Revision 25 Revision 25 to the McGuire Unit 2 COLR contains limits specific to the McGuire Unit 2 Cycle 17 core and may become effective any time after no-mode is reached between Cycles 16 and 17. This revision must become effective prior to entering Mode 6 that starts Cycle 17.

MCEI-040047 Page 4 of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report REVISION LOG Revision Revisions 0-2 Revisions 3-6 Revisions 7-12 Revision 13-15 Revision 16-17 Revision 18-20 Revision 21-22 Revision 23 Revision 24 Revision 25 Issuance Date Superseded Superseded Superseded Superseded Superseded Superseded Superseded September 3, 2003 January 26, 2003 February 22, 2004 Effective Pages N/A N/A N/A N/A N/A N/A N/A N/A N/A 1-33 COLR M2C09 M2CIO M2CHI M2C12 M2C13 M2C14 M2C15 M2C16 (Orig. Issue)

M2C16 (Rev. 1)

M2C17 (Orig. Issue)

MCEI-040047 Page 5 of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report Insertion Sheet For Revision 25 Remove pages Pages 1 - 33 Appendix A*

Insert Rev. 25 pages Pages I - 33 Appendix A*

  • Appendix A contains power distribution Monitoring Factors used in Technical Specification Surveillance. Appendix A is only included in the COLR copy sent to the NRC.

MCEI-040047 Page 6 of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report 1.0 Core Operating Limits Report This Core Operating Limits Report (COLR) has been prepared in accordance with the requirements of Technical Specification 5.6.5. The Technical Specifications that reference the COLR are summarized below.

TS Number 1.1 2.1.1 3.1.1 3.1.3 3.1.4 3.1.5 3.1.5 Technical Specifications Requirements for Operational Mode 6 Reactor Core Safety Limits Shutdown Margin Moderator Temperature Coefficient Rod Group Alignment Limits Shutdown Bank Insertion Limits Shutdown Bank Insertion Limits 3.1.6 Control Bank Insertion Limits 3.1.6 Control Bank Insertion Limits 3.1.8 Physics Test Exceptions 3.2.1 Heat Flux Hot Channel Factor 3.2.2 Nuclear Enthalpy Rise Hot Channel Factor 3.2.3 Axial Flux Difference 3.3.1 Reactor Trip System Instrumentation Setpoint 3.4.1 RCS Pressure, Temperature and Flow limits for DNB 3.5.1 Accumulators 3.5.4 Refueling Water Storage Tank 3.7.14 Spent Fuel Pool Boron Concentration 3.9.1 Refueling Operations - Boron Concentration 5.6.5 Core Operating Limits Report (COLR)

COLR Parameter Mode 6 Definition RCS Temperature and Pressure Safety Limits Shutdown Margin MTC Shutdown Margin Shutdown Margin Shutdown Bank Insertion Limit Shutdown Margin Control Bank Insertion Limit Shutdown Margin Fq, AFD, OTAT and Penalty Factors FAH, AFD and Penalty Factors AFD OTAT and OPAT Constants RCS Pressure, Temperature and Flow Max and Min Boron Conc.

Max and Min Boron Conc.

Min Boron Concentration Min Boron Concentration Analytical Methods COLR Section 2.1 2.2 2.3 2.4 2.3 2.3 2.5 2.3 2.6 2.3 2.7 2.8 2.9 2.10 2.11 2.12 2.13 2.14 2.15 1.1 El Page 9

9 9

11 9

9 11 9

11 9

16 21 22 25 27 27 27 29 29 7

The Selected Licensee Commitments that reference this report are listed below:

SLC Number Selected Licensing Commitment COLR Parameter 16.9.14 16.9.11 Borated Water Source - Shutdown Borated Water Volume and Conc. for BAT/RWST Borated Water Source - Operating Borated Water Volume and Conc. for BAT/RWST COLR Section 2.16 2.17 El Page 30 31

MCEI-040047 Page 7 of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report 1.1 Analytical Methods The analytical methods used to determine core operating limits for parameters identified in Technical Specifications and previously reviewed and approved by the NRC as specified in Technical Specification 5.6.5 are as follows.

1. WCAP-9272-P-A, "Westinghouse Reload Safety Evaluation Methodology," (W Proprietary).

Revision 0 Report Date: July 1985 Not Used for M2C17

2. WCAP-10054-P-A, "Westinghouse Small Break ECCS Evaluation Model using the NOTRUMP Code, " (W Proprietary).

Revision 0 Report Date: August 1985

3. WCAP-10266-P-A, "The 1981 Version Of Westinghouse Evaluation Model Using BASH Code",

(W Proprietary).

Revision 2 Report Date: March 1987 Not Used for M2C17

4. WCAP-12945-P-A, Volume 1 and Volumes 2-5, "Code Qualification Document for Best-Estimate Loss of Coolant Analysis," (W Proprietary).

Revision: Volume 1 (Revision 2) and Volumes 2-5 (Revision 1)

Report Date: March 1998

5. BAW-10168P-A, "B&W Loss-of-Coolant Accident Evaluation Model for Recirculating Steam Generator Plants," (B&W Proprietary).

Revision I SER Date: January 22, 1991 Revision 2 SER Dates: August 22, 1996 and November 26, 1996.

Revision 3 SER Date: June 15, 1994.

Not Used for M2C17

6. DPC-NE-3000PA, "Thermnal-Hydraulic Transient Analysis Methodology:' (DPC Proprietary).

Revision 3 SER Date: September 24, 2003

MCEI-0400-47 Page 8 of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report 1.1 Analytical Methods (continued)

7. DPC-NE-300IPA, "Multidimensional Reactor Transients and Safety Analysis Physics Parameter Methodology," (DPC Proprietary).

Revision 0 Report Date: November 15. 1991 (Republished December 2000)

8. DPC-NE-3002A, "FSAR Chapter 15 System Transient Analysis Methodology".

Revision 4 SER Date: April 6, 2001

9. DPC-NE-2004P-A. "Duke Power Company McGuire and Catawba Nuclear Stations Core Thermal-Hydraulic Methodology using VIPRE-0 1," (DPC Proprietary).

Revision I SER Date: February 20, 1997

10. DPC-NE-2005P-A, "Thermal Hydraulic Statistical Core Design Methodology." (DPC Proprietary).

Revision 3 SER Date: September 16, 2002 1 1. DPC-NE-2008P-A, "Fuel Mechanical Reload Analysis Methodology Using TACO3V" (DPC Proprietary).

Revision 0 SER Date: April 3, 1995 Not Used for M2C17

12. DPC-NE-2009-P-A, "Westinghouse Fuel Transition Report," (DPC Proprietary).

Revision 2 SER Date: December 18, 2002

13. DPC-NE-1004A, "Nuclear Design Methodology Using CASMO-3/SIMULATE-3P."

Revision I SER Date: April 26, 1996

14. DPC-NF-2010A. "Duke Power Company McGuire Nuclear Station Catawba Nuclear Station Nuclear Physics Methodology for Reload Design."

Revision 2 SER Date: June 24, 2003

MCEI-0400-47 Page 9 of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report 1.1 Analytical Methods (continued)

15. DPC-NE-201 IPA, "Duke Power Company Nuclear Design Methodology for Core Operating Limits of Westinghouse Reactors," (DPC Proprietary).

Revision I SER Date: October 1, 2002 2.0 Operating Limits The cycle-specific parameter limits for the specifications listed in Section 1.0 are presented in the following subsections. These limits have been developed using the NRC approved methodologies specified in Section 1.1.

2.1 Requirements for Operational Mode 6 The following condition is required for operational mode 6.

2.1.1 The Reactivity Condition requirement for operational mode 6 is that kff must be less than, or equal to 0.95.

2.2 Reactor Core Safety Limits (TS 2.1.1) 2.2.1 The Reactor Core Safety Limits are shown in Figure 1.

2.3 Shutdown Margin - SDM (TS 3.1.1, TS 3.1.4, TS 3.1.5, TS 3.1.6 and TS 3.1.8) 2.3.1 ForTS 3.1.1, SDM shall be> 1.3% AKIK in mode 2 with k-eff< 1.0 and in modes 3 and 4.

2.3.2 ForTS 3.1.1, SDM shall be> 1.0% AK/K in mode 5.

2.3.3 ForTS 3.1.4, SDM shall be > 1.3% AK/K in modes I and 2.

2.3.4 For TS 3.1.5. SDM shall be > 1.3% AK/K in mode 1 and mode 2 with any control bank not fully inserted.

2.3.5 ForTS 3.1.6, SDM shall be > 1.3% AK/K in mode I and mode 2 with K-eff > 1.0.

2.3.6 ForTS 3.1.8, SDM shall be > 1.3% AK/K in mode 2 during Physics Testing.

MCEI-040047 Page 10 of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report Figure 1 Reactor Core Safety Liits Four Loops in Operation DO NOT OPERATE IN THIS AREA 660 650 640 v

630 2280 pSia Q

620

~21 00 psia\\

610 600 590 ACCEPTABLE 580 l 1

I 0.0 0.2 0.4 0.6 0.8 1.0 1.2 Fraction of Rated Thermal Power

MCEI.0400-47 Page I I of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report 2.4 Moderator Temperature Coefficient - MTC (TS 3.1.3) 2.4.1 The ModeratorTemperature Coefficient (MTC) Limits are:

The MTC shall be less positive than the upper limits shown in Figure 2. The BOC, ARO, HZP MTC shall be less positive than 0.7E-04 AK/K/IF.

The EOC, ARO, RTP MTC shall be less negative than the -4.3E-04 AK/K/0F lower MTC limit.

2.4.2 The 300 ppm MTC Surveillance Limit is:

The measured 300 PPM ARO, equilibrium RTP MTC shall be less negative than or equal to -3.65E-04 AKfK/IF.

2.4.3 The 60 PPM MTC Surveillance Limit is:

The 60 PPM ARO, equilibrium RTP MTC shall be less negative than or equal to

-4.125E-04 AK/K/OF.

Where, BOC = Beginning of Cycle (Bumup corresponding to the most positive MTC)

EOC = End of Cycle ARO = All Rods Out HZP = Hot Zero Power RTP = Rated Thermal Power PPM = Parts per million (Boron) 2.5 Shutdown Bank Insertion Limit (TS 3.1.5) 2.5.1 Each shutdown bank shall be withdrawn to at least 222 steps. Shutdown banks are withdrawn in sequence and with no overlap.

2.6 Control Bank Insertion Limits (TS 3.1.6) 2.6.1 Control banks shall be within the insertion, sequence, and overlap limits shown in Figure 3. Specific control bank withdrawal and overlap limits as a function of the fully withdrawn position are shown in Table 1.

MCEI-040047 Page 12 of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report Figure 2 Moderator Temperature Coefficient Upper Limit Versus Power Level 1.0 C-.

C

.. I To Q

E 1W 0

V CU I--

0 0.I 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.0 0

10 20 30 40 50 60 70 80 90 100 Percent of Rated Thermal Power NOTE: Compliance with Technical Specification 3.1.3,may require rod withdrawal limits.

Refer to OP121A16100/22 Unit 2 Data Book for details.

MCEI-0400-47 Page 13 of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report Figure 3 Control Bank Insertion Limits Versus Percent Rated Thermal Power Fully Withdrawn (Maximum = 231)

\\

231 220 200

!: 180-

,c 160-U, P. 140

, 120-0

6. 163 (29.6

.23

...... Fully Withdrawn (Minimum 222 Control Bank Control Bank C 2+

(80.0%. 231) )

/.,,,._

Cot_.

_ n D.... I

)I).

U,-

0 A..

.21 10 100 _

80 -

60 L X

I I

v 0

10 20 30 40 50 60 70 80 90 100 Percent of Rated Thermal Power NOTE: Compliance with Technical Specification 3.1.3 may require rod withdrawal limits.

Refer to OP12/A16100/22 Unit 2 Data Book for details.

MCEI-0400-47 Page 14 of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report Table 1 RCCA Withdrawal Steps and Sequence RCCAs Fully Withdrawn at 222 SWD Control Control Control Control Bank A Bank B Bank C Bank D 0 Start 0

0 0

116 OStart 0

0 222 Stop 106 0

0

.222 116 0 Start.

0 222 222 Stop 106 0

222 222 116 0 Start 222 222 222 Stop 106 RCCAs Fully Withdrawn at 223 SWD Control Control Control Control Bank A Bank B Bank C Bank D 0 Start 0

0 0

116 0 Start 0

0 223 Stop 107 0

0 223 116 0 Start 0

223 223 Stop 107 0

223 223 116 0 Start 223 223 223 Stop 107 RCCAs Fully Withdrawn at 224 SWD Control Control Control Control Bank A Bank B Bank C Bank D OStart 0

0 0

116 OStart 0

0 224 Stop 108 0

0 224 116 0 Start 0

224 224 Stop 108 0

224 224 116 0 Start 224 224 224 Stop 108 RCCAs Fully Withdrawn at 225 SWD Control Control Control Control Bank A Bank B Bank C Bank D OStart 0

0 0

116 OStart 0

0 225 Stop 109 0

0 225 116 0 Start 0

225 225 Stop 109 0

225 225 116 0 Start 225 225 225 Stop 109 RCCAs Fully Withdrawn at 226 SWD Control Control Control

. Control Bank A Bank B Bank C Bank D 0 Start 0

0 0

116 0 Start 0

0 226 Stop 110 0

0 226 116 0 Start 0

226 226 Stop 110 0

226 226 116 0 Start 226 226 226 Stop 110 RCCAs Fully Withdrawn at 227 SWD Control Control Control Control Bank A Bank B Bank C Bank D 0 Start 0

0 0

116 0 Start 0

0 227 Stop 111 0

0 227 116 0 Start 0

227 227 Stop 111 0

227 227 116 0 Start 227 227 227 Stop 111

MCEI-0400-47 Page 15 of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report Table 1 Continued RCCA Withdrawal Steps and Sequence RCCAs Fully Withdrawn at 228 SWD Control Control Control Control Bank A Bank B Bank C Bank D 0 Start 0

0 0

116 0 Start 0

0 228 Stop 112 0

0 228 116 0 Start 0

228 228 Stop 112 0

228 228 116 0 Stan 228 228 228 Stop 112 RCCAs Fully Withdrawn at 229 SWD Control Control Control Control Bank A Bank B Bank C Bank D 0 Start 0

0 0

116 0 Start 0

0 229 Stop 113 0

0 229 116 0 Start 0

229 229 Stop 113 0

229 229 116 0 Start 229 229 229Stop 113 RCCAs Fully Withdrawn at 230 SWD Control Control Control Control Bank A Bank B Bank C Bank D 0 Start 0

0 0

116 0 Start 0

0 230 Stop 114 0

0 230 116 0 Start 0

230 230 Stop 114 0

230 230 116 0 Start 230 230 230 Stop 114 RCCAs Fully Withdrawn at 231 SWD Control Control Control Control Bank A Bank B Bank C Bank D 0 Sart 0

0 0

116 0 Start 0

0 231Stop 115 0

0 231 116 0Start 0

231 231 Stop 115 0

231 231 116 OStart 231 231 231 Stop 115

MCEI-0400-47 Page 16 of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report 2.7 Heat Flux Hot Channel Factor - FQ(XY,Z) (TS 3.2.1) 2.7.1 FQ(X,YZ) steady-state limits are defined by the following relationships:

F RP *K(Z)IP for P > 0.5 F RP *K(Z)/0.5 for P < 0.5

where, P = (Thermal Power)/(Rated Power)

Note: The measured FQ(X,YZ) shall be increased by 3% to account for manufacturing tolerances and 5% to account for measurement uncertainty when comparing against the LCO limits. The manufacturing tolerance and measurement uncertainty are implicitly included in the FQ surveillance limits as defined in COLR Sections 2.7.5 and 2.7.6.

2.7.2 FQ =2.60 x K(BU) 2.7.3 K(Z) is the normalized FQ(X,YZ) as a function of core height. The K(Z) function for Westinghouse RFA fuel is provided in Figure 4.

2.7.4 K(BU) is the normalized FQ(XY,Z) as a function of burnup. K(BU) for Westinghouse RFA fuel is 1.0 for all burnups.

The following parameters are required for core monitoring per the Surveillance Requirements of Technical Specification 3.2.1:

F25(X,Y,Z)

  • MQ(X,Y,Z) 2.7.5 FQ(XYZ)OP ='UMT
  • TILT where:

FQ (X,YZ)OP =

Cycle dependent maximum allowable design peaking factor that ensures that the FQ(X,Y,Z) LOCA limit will be preserved for operation within the LCO limits. FQ (X,YZ)OP includes allowances for calculation and measurement uncertainties.

FJ' (X,Y,Z) = Design power distribution for FQ. F D (X,Y,Z) is provided in Appendix A Table A-I for normal operating conditions, and in

MCEI-0400-47 Page 17 of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report Appendix A Table A-2 for power escalation testing during initial startup operation.

MQ(X,YZ)

=

Margin remaining in core location X,YZ to the LOCA limit in the transient power distribution. MQ(X,Y,Z) is provided in Appendix A Table A-I for normal operating conditions, and in Appendix A Table A-2 for power escalation testing during initial startup operation.

UMT = Total Peak Measurement Uncertainty. (UMT = 1.05)

MT = Engineering Hot Channel Factor. (MT = 1.03)

TILT = Peaking penalty that accounts for the peaking increase from an allowable quadrant power tilt ratio of 1.02. (TILT = 1.035) 2.7.6 FL(X,Y,Z)RPS =

Fg(X,Y,Z)

  • MC(X,Y,Z) 1MT
  • TILT where:

F'(X,Y,Z)RPS =

Cycle dependent maximum allowable design peaking factor that ensures that the FQ(X,Y,Z) Centerline Fuel Melt (CFM) limit will be preserved for operation within the LCO limits.

FQ(X,Y,Z)RPS includes allowances for calculation and measurement uncertainties.

FQ(X,Y,Z) =

MC(X,Y,Z) =

Design power distributions for FQ. FQ(X,Y,Z) is provided in Appendix A Table A-I for normal operating conditions, and in Appendix A Table A-2 for power escalation testing during initial startup operation.

Margin remaining to the CFM limit in core location X,YZ from the transient power distribution. MC(X,Y,Z) is provided in Appendix A Table A-3 for normal operating conditions, and in Appendix A Table A-4 for power escalation testing during initial startup operation.

UNMT = Total Peak Measurement Uncertainty (UMT = 1.05)

MCEI-0400-47 Page 18 of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report MT = Engineering Hot Channel Factor (MT = 1.03)

TILT =

Peaking penalty that accounts for the peaking increase from an allowable quadrant power tilt ratio of 1.02. (TILT = 1.035) 2.7.7 KSLOPE = 0.0725 where:

KSLOPE is the adjustment to the K1 value from the OTAT trip setpoint required to compensate for each 1% that Fm (X,Y,Z) exceeds FL (X,Y,Z) 2.7.8 FQ(X,Y,Z) penalty factors forTechnical Specification Surveillance's 3.2.1.2 and 3.2.1.3 are provided in Table 2.

MCEI-0400-47 Page 19 of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report Figure 4 K(Z), Normalized FQ(XY,Z) as a Function of Core Height for Westinghouse RFA Fuel 1.200 (0.0, 1.00)

(4.0. 1.00) 1.000 0.800 -

.I (4.0,0.9615)

(12.0,0.9615)

R 0.600 4 0.400 0.200 !

n un ulwu1111 0.00 2.00 4.00 6.00 Core Height (ft) 8.00 10.00 12.00

MCEI-040047 Page 20 of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report Table 2 FQ(X,Y,Z) and FMI(X,Y) Penalty Factors For Technical Specification Surveillance's 3.2.1.2,3.2.1.3 and 3.2.2.2 Burnup (EFPD) 0 4

12 25 50 75 100 125 150 175 200 225 250 275 300 536 FQ(XYZ)

Penalty Factor (%)

2.00 2.00 2.00 2.63 2.83 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 FAH(XYZ)

Penalty Factor (%)

2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 Note: Linear interpolation is adequate for intermediate cycle bumups. All cycle burnups outside of the range of the table shall use a 2% penalty factor for both FQ(X,Y,Z) and FAH(X,Y) for compliance with the Technical Specification Surveillances 3.2.1.2, 3.2.1.3 and 3.2.2.2.

MCEI-0400-47 Page 21 of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report 2.8 Nuclear Enthalpy Rise Hot Channel Factor - FAII(X,Y) (TS 3.2.2)

The FAH steady-state limits referred to in Technical Specification 3.2.2 is defined by the following relationship.

2.8.1 FL (X Y)cc'= MARP (X,Y) *[1.0 +

  • (1.0 -

where:

Figs (X, Y)Lco is defined as the steady-state, maximum allowed radial peak.

Fall (X, Y)LCo includes allowances for calculation-measurement uncertainty.

MARP(X,Y) =

Cycle-specific operating limit Maximum Allowable Radial Peaks. MARP(X,Y) radial peaking limits are provided in Table 3.

p Thermal Power Rated Thermal Power RRH =Thermal Power reduction required to compensate for each 1% that the measured radial peak, FM, (X,Y), exceeds its limit. RRH also is used to scale the MARP limits as a function of power per the [Fal (X, Y)]'Co equation. (RRH = 3.34 (0.0 < P < 1.0))

The following parameters are required for core monitoring per the Surveillance requirements of Technical Specification 3.2.2.

2.8.2 FZMIIIX

)SURV = F^,,(X,Y)XM4,',(X,Y) 22:UMR xTLT where:

FJ (X,Y)

Cycle dependent maximum allowable design peaking factor that ensures that the FAH(XY) limit will be preserved for operation within the LCO limits. F~L, (X,Y) includes allowances for calculation-measurement uncertainty.

MCEI-0400-47 Page 22 of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report FADES (XY) = Design radial power distribution for F,,H FAH (X,Y) is provided in Appendix A Table A-5 for normal operation, and in Appendix A Table A-6 for power escalation testing during initial startup operation.

MAH(XY)

=The margin remaining in core location X,Y relative to the Operational DNB limits in the transient power distribution.

MAH(XY) is provided in Appendix A Table A-5 for normal operation, and in Appendix A Table A-6 for power escalation testing during initial startup operation.

UMR =Uncertainty value for measured radial peaks, (UMR= 1.04).

UMR is set to 1.0 since a factor of 1.04 is implicitly included in the variable MAH(X,Y).

TILT = Peaking penalty that accounts for the peaking increase for an allowable quadrant power tilt ratio of 1.02, (TILT = 1.035).

2.8.3 RRH = 3.34 where:

RRH = Thermal power reduction required to compensate for each 1% that the measured radial peak, FH (XY) exceeds its limit.

2.8.4 TRH = 0.04 where:

TRH = Reduction in the OTAT Kj setpoint required to compensate for each 1%

that the measured radial peak, FS (X,Y) exceeds its limit.

2.8.5 FSH (XY) penalty factors for Technical Specification Surveillance 3.2.2.2 are provided in Table 2.

2.9 Axial Flux Difference - AFD (TS 3.2.3) 2.9.1 The Axial Flux Difference (AFD) Limits are provided in Figure 5.

MCEI-0400-47 Page 23 of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report Table 3 Maximum Allowable Radial Peaks (MARPS)

RFA MARPS Core Axial Peak-->

[it (ft.)

1.05 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.1 3.0 3.25 0.12 1.847 1.882 1.947 1.992 1.974 2.068 2.090 2.049 1.972 1.900 1.778 1.315 1.246 1.2 1.843 1.879 1.938 1.992 1.974 2.068 2.054 2.012 1.935 1.862 1.785 1.301 1.224 2.4 1.846 1.876 1.931 1.981 1.974 2.068 2.025 1.981 1.903 1.832 1.757 1.468 1.456 3.6 1.843 1.869 1.920 1.964 1.974 2.068 2.005 1.968 1.892 1.820 1.716 1.471 1.431 4.8 1.838 1.868 1.906 1.945 1.974 2.006 1.945 1.925 1.862 1.802 1.725 1.326 1.285 6.0 1.834 1.856 1.891 1.921 1.946 1.934 1.878 1.863 1.802 1.747 1.673 1.384 1.317 7.2 1.828 1.845 1.871 1.893 1.887 1.872 1.809 1.787 1.732 1.681 1.618 1.316 1.277 8.4 1.823 1.829 1.847 1.857 1.816 1.795 1.739 1.722 1.675 1.630 1.551 1.247 1.211 9.6 1.814 1.812 1.809 1.792 1.738 1.724 1.678 1.665 1.621 1.578 1.492 1.191 1.137 10.8 1.798 1.784 1.761 1.738 1.697 1.682 1.626 1.605 1.558 1.512 1.430 1.149 1.097 11.4 1.789 1.765 1.725 1.684 1.632 1.614 1.569 1.557 1.510 1.466 1.392 1.113 1.060 7

MCEI-0400-47 Page 24 of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report Figure 5 Percent of Rated Thermal Power Versus Percent Axial Flux Difference Limits 90 W

0.

2 F-lo 0:

.U 2~

3.

Oa c.

Unacceptable C

(-36, 50) 80 Unacceptable Operation Acceptable Operation 70 60 50

(+21,50) 40 30 20 10

-50

-40

-30

-20

-10 0

10 20 30 40 50 Axial Flux Difference (% Delta I)

NOTE: Compliance with Technical Specification 3.2.1 may require more restrictive AFD limits. Refer to OP/2/A16100122 Unit 2 Data Book of more details.

MCEI-040047 Page 25 of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report 2.10 Reactor Trip System Instrumentation Setpoints (TS 3.3.1) Table 3.3.1-1 2.10.1 Overtemperature AT Setpoint Parameter Values Parameter Value Nominal Tavg at RTP T' < 585.1IF Nominal RCS Operating Pressure Overtemperature AT reactor trip setpoint Overtemperature AT reactor trip heatup setpoint penalty coefficient Overtemperature AT reactor trip depressurization setpoint penalty coefficient Time constants utilized in the lead-lag compensator for AT Time constant utilized in the lag compensator for AT P'= 2235 psig KI < 1.1978 K2 = 0.0334/ 0 F K3 = 0.001601/psi T8 >8sec.

r2 < 3 sec.

tr3 < 2.0 sec.

Time constants utilized in the lead-lag compensator for T.,,

Time constant utilized in the measured Tavg lag compensator fl(Al) "positive" breakpoint fl (AI) "negative" breakpoint fi(Al) "positive" slope

¶4 > 28 sec.

¶5< 4 sec.

6 < 2.0 sec.

= 19.0 %AI

= N1A*

= 1.769 YoATCl %Al fI(Al) "negative" slope

= NIA*

  • The fl(Al) "negative" breakpoints and the fI(Al) "negative" slope are less restrictive than the OPAT f2(AI) negative breakpoint and slope. Therefore, during a transient which challenges the negative imbalance limits, the OPAT f2 (AI) limits will result in a reactor trip before the OTAT fl(Al) limits are reached. This makes implementation of the OTAT fl(Al) negative breakpoint and slope unnecessary.

MCEI-040047 Page 26 of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report 2.10.2 Overpower AT Setpoint Parameter Values Parameter Nominal Tavg at RTP Overpower AT reactor trip setpoint Overpower AT reactor trip Penalty Overpower AT reactor trip heatup setpoint penalty coefficient Time constants utilized in the lead-lag compensator for AT Time constant utilized in the lag compensator for AT Time constant utilized in the measured Tnvg lag compensator Time constant utilized in the rate-lag controller for Tayg f2(AI) "positive" breakpoint f2(AI) "negative" breakpoint f2(AI) "positive" slope f2(AI) "negative" slope Value T" <585.1IF K4 < 1.0864 K5 = 0.02/0F for increasing Tavg K5 = 0.0 for decreasing Tavg K 6 =0.001179/0 FforT>T'"

K6 =0.0 forT<T'"

T, > 8 sec.

2 < 3 sec.

T3 < 2.0 sec.

T6< 2.0sec.

> 5 sec.

= 35.0 %AI

= -35.0 %AI 7.0 %ATo/ %AI 7.0 %ATd %AI

MCEI-0400-47 Page 27 of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report 2.11 RCS Pressure, Temperature and Flow Limits for DNB (TS 3.4.1) 2.11.1 The RCS pressure, temperature and flow limits for DNB are shown in Table 4.

2.12 Accumulators (TS 3.5.1) 2.12.1 Boron concentration limits during modes I and 2, and mode 3 with RCS pressure

>1000 psi:

Parameter Cold Leg Accumulator minimum boron concentration.

Cold Leg Accumulator maximum boron concentration.

Limit 2,475 ppm 2,875 ppm 2.13 Refueling Water Storage Tank - RWST (TS 3.5.4) 2.13.1 Boron concentration limits during modes 1, 2, 3, and 4:

Parameter Refueling Water Storage Tank minimum boron concentration.

Refueling Water Storage Tank maximum boron concentration.

Limit 2,675 ppm 2,875 ppm

MCEI-0400-47 Page 28 of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report Table 4 Reactor Coolant System DNB Parameters No. Operable Parameter Indication Channels Limits

1. Indicated RCS Average Temperature meter 4

< 587.2 'F meter 3

< 586.9 IF computer 4

< 587.7 OF computer 3

< 587.5 IF

2. Indicated Pressurizer Pressure meter 4

> 2219.8 psig meter 3

> 2222.1 psig computer 4

> 2215.8 psig computer 3

> 2217.5 psig

3. RCS Total Flow Rate

> 388,000 gpm

MCEI-0400-47 Page 29 of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report 2.14 Spent Fuel Pool Boron Concentration (TS 3.7.14) 2.14.1 Minimum boron concentration limit for the spent fuel pool. Applicable when fuel assemblies are stored in the spent fuel pool.

Parameter Limit Spent fuel pool minimum boron concentration.

2,675 ppm 2.15 Refueling Operations - Boron Concentration (TS 3.9.1) 2.15.1 Minimum boron concentration limit for the filled portions of the Reactor Coolant System, refueling canal, and refueling cavity for mode 6 conditions. The minimum boron concentration limit and plant refueling procedures ensure that the Keff of the core will remain within the mode 6 reactivity requirement of Keff <

0.95.

Parameter Limit Minimum Boron concentration of the Reactor Coolant System, the refueling canal, and the refueling cavity.

2,675 ppm

MCEI-0400-47 Page 30 of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report 2.16 Borated Water Source - Shutdown (SLC 16.9.14) 2.16.1 Volume and boron concentrations for the Boric Acid Tank (BAT) and the Refueling Water Storage Tank (RWST) during mode 4 with any RCS cold leg temperature < 300 'F and modes 5 and 6.

Parameter Limit Boric Acid Tank minimum contained borated water volume 10,599 gallons 13.6% Level Note: When cycle burnup is > 460 EFPD, Figure 6 may be used to determine the required BAT minimum level.

Boric Acid Tank minimum boron concentration Boric Acid Tank minimum water volume required to maintain SDM at 7,000 ppm Refueling Water Storage Tank minimum contained borated water volume Refueling Water Storage Tank minimum boron concentration Refueling Water Storage Tank minimum water volume required to maintain SDM at 2,675 ppm 7,000 ppm 2,300 gallons 47,700 gallons 41 inches 2,675 ppm 8,200 gallons

MCEI-040047 Page 31 of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report 2.17 Borated Water Source - Operating (SLC 16.9.11) 2.17.1 Volume and boron concentrations for the Boric Acid Tank (BAT) and the Refueling Water Storage Tank (RWST) during modes 1, 2, 3, and mode 4 with all RCS cold leg temperature > 300 OF.

Parameter Limit Boric Acid Tank minimum contained borated water volume 22,049 gallons 38.0% Level Note: When cycle burnup is > 460 EFPD, Figure 6 may be used to determine the required BAT minimum level.

Boric Acid Tank minimum boron concentration Boric Acid Tank minimum water volume required to maintain SDM at 7,000 ppm Refueling Water Storage Tank minimum contained borated water volume Refueling Water Storage Tank minimum boron concentration Refueling Water Storage Tank maximum boron concentration (TS 3.5.4)

Refueling Water Storage Tank minimum water volume required to maintain SDM at 2,675 ppm 7,000 ppm 13,750 gallons 96,607 gallons 103.6 inches 2,675 ppm 2,875 ppm 57,107 gallons

MCEI-040047 Page 32 of 33 Revision 25 McGuire 2 Cycle 17 Corie Operating Limits Report Figure 6 Boric Acid Storage Tank Indicated Level Versus RCS Boron Concentration (Valid When Cycle Burnup is > 460 EFPD)

This figure includes additional volumes listed in SLC 16.9-14 and 16.9-11 40.0 RCS Boron

35.0 Concentration; BAT Level (ppm)

(*/*level)

X.0 < 300 j 37.0_

300< 500 33.0 30.0

_500 < 700 28.0 700.1000 23.0 1000 < 1300 13.6 25.0 -

>1300 8.7 20.0.

Acceptable Operation 15.0 -

10.0]

I lUnacceptable Operation 5.0

i.

0 200 400 600 800 1000 1200 1400 16D0 1800 2000 2200 2400 2600 2800 RCS Boron Concentration (ppmb)

MCEI-040047 Page 33 of 33 Revision 25 McGuire 2 Cycle 17 Core Operating Limits Report NOTE: Data contained in the Appendix to this document was generated in the McGuire 2 Cycle 17 Maneuvering Analysis calculation file, MCC-1553.05-00-0408. Appendix A contains power distribution monitoring factors used in Technical Specification Surveillance. Due to the size of the monitoring factor data, Appendix A is controlled electronically within Duke and is not included in the Duke internal copies of the COLR.

The McGuire Nuclear Engineering Section will control this information via computer file(s) and should be contacted if there is a need to access this information.