Cycle 21, Revision 0, Core Operating Limits Report
ML101100461
Person / Time
Site: McGuire Duke Energy icon.png
Issue date: 04/14/2010
From: Repko R
Duke Energy Carolinas
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
MCEI-0400-232, Rev 0
Download: ML101100461 (34)


Text

Duke REGIS T.

REPKO Energy.Vice President Energy.

McGuire Nuclear Station Duke Energy MG01 VP /12700 Hagers Ferry Rd.

Huntersville, NC 28078 980-875-4111 980-875-4809 fax regis. repko@duke-energy. corn April 14, 2010 U. S. Nuclear Regulatory Commission Document Control Desk Washington, D.C. 20555

Subject:

Duke Energy Carolinas, LLC (Duke)

McGuire Nuclear Station Docket Nos. 50-369 Unit 1, Cycle 21, Revision 0 Core Operating Limits Report Pursuant to McGuire Technical Specification (TS) 5.6.5.d, please find enclosed Revision 0 of the McGuire Unit 1 Cycle 21 Core Operating Limits Report (COLR).

Revision 0 of the McGuire Unit 1 Cycle 21 COLR contains limits specific to the reload core.

Questions regarding this submittal should be directed to Kay Crane, McGuire Regulatory Compliance at (980) 875-4306.

Regis T. Repko Attachment RcýD www. duke-energy. corn

U. S. Nuclear Regulatory Commission April 14, 2010 Page 2 cc:

Mr. Jon H. Thompson, Project Manager U.S. Nuclear Regulatory Commission 11555 Rockville Pike Rockville, MD 20852-2738 Mr. Luis A. Reyes Regional Administrator U. S. Nuclear Regulatory Commission, Region II Marquis One Tower 245 Peachtree Ave., NE, Suite 1200 Atlanta, Georgia 30303-1257 Mr. Joe Brady Senior Resident Inspector McGuire Nuclear Station

MCEI-0400-232

.Page 1 of 32 Revision 0 McGuire Unit 1 Cycle 21 Core Operating Limits Report Revision 0 March 2010 Calculation Number: MCC-1553.05-00-0519, Rev. 0 Duke Energy Date Pr red By:

Checked By:

Checked By:

Approved By:

(Sections 2.2 and

-18) 3i/,o 3 AI/

QA Condition 1 The information presented in this report has been prepared and issued in accordance with McGuire Technical Specification 5.6.5.

MCEI-0400-232 Page 2 of 32 Revision 0 McGuire 1 Cycle 21 Core Operating Limits Report INSPECTION OF ENGINEERING INSTRUCTIONS (cS pso)

Inspection Waived By:

(Sponsor)

Date: 3 h/

/o t)

CATAWBA MCE (Mechanical & Civil)

RES (Electrical Only)

RES (Reactor)

MOD Other(

)

Inspection Waived El El El E]

Inspected By/Date:

Inspected By/Date:

Inspected By/Date:

Inspected By/Date:

Inspected By/Date:

OCONEE MCE (Mechanical & Civil)

RES (Electrical Only)

RES (Reactor)

MOD Other(

)

Inspection Waived El El El El El Inspected By/Date:

Inspected By/Date:

Inspected By/Date:

Inspected By/Date:

Inspected By/Date:

MCGUIRE MCE (Mechanical & Civil)

RES (Electrical Only)

RES (Reactor)

MOD Other (

)

Inspection Waived El E]

Inspected By/Date:

Inspected By/Date:

Inspected By/Date:

Inspected By/Date:

Inspected By/Date:

MCEI-0400-232 Page 3 of 32 Revision 0 McGuire 1 Cycle 21 Core Operating Limits Report Implementation Instructions for Revision 0 Revision Description and PIP Tracking Revision 0 of the McGuire Unit I Cycle 21 COLR contains limits specific to the reload core. There is no PIP associated with this revision.

Implementation Schedule Revision 0 may become effective any time during No MODE between cycles 20 and 21 but must become effective prior to entering MODE 6 which starts cycle 21. The McGuire Unit I Cycle 21 COLR will cease to be effective during No MODE between cycle 21 and 22.

Data files to be Implemented No data files are transmitted as part of this document.

MCEI-0400-232 Page 4 of 32 Revision 0 McGuire 1 Cycle 21 Core Operating Limits Report REVISION LOG Pages Affected 1-32, Appendix A*

Revision Effective Date 0

March 2010 COLR M1 C21 COLR, Rev. 0 Appendix A contains power distribution monitoring factors used in Technical Specification Surveillance. Appendix A is included only in the electronic COLR copy sent to the NRC.

MCEI-0400-232 Page 5 of 32 Revision 0 McGuire 1 Cycle 21 Core Operating Limits Report 1.0 Core Operating Limits Report This Core Operating Limits Report (COLR) has been prepared in accordance with the requirements of the Technical Specification 5.6.5. The Technical Specifications that reference the COLR are summarized below.

TS Number 1.1 2.1.1 3.1.1 3.1.3 3.1.4 3.1.5.

3.1.5 Technical Specifications Requirements for Operational Mode 6 Reactor Core Safety Limits Shutdown Margin Moderator Temperature Coefficient Rod Group Alignment Limits Shutdown Bank Insertion Limits Shutdown Bank Insertion Limits 3.1.6 Control Bank Insertion Limits 3.1.6 Control Bank Insertion Limits 3.1.8 Physics Test Exceptions 3.2.1 Heat Flux Hot Channel Factor 3.2.2 Nuclear Enthalpy Rise Hot Channel Factor 3.2.3 Axial Flux Difference 3.3.1 Reactor Trip System Instrumentation Setpoint 3.4.1 RCS Pressure, Temperature and Flow limits for DNB 3.5. 1 Accumulators 3.5.4 Refueling Water Storage Tank 3.7.14 Spent Fuel Pool Boron Concentration 3.9.1 Refueling Operations - Boron Concentration 5.6.5 Core Operating Limits Report (COLR)

COLR Parameter Mode 6 Definition RCS Temperature and Pressure Safety Limits Shutdown Margin MTC Shutdown Margin Shutdown Margin Shutdown Bank Insertion Limit.

Shutdown.Margin Control Bank Insertion Limit Shutdown Margin Fq, AFD, OTAT and Penalty Factors FAH, AFD and Penalty Factors AFD OTAT and OPAT Constants RCS Pressure, Temperature and Flow Max and Min Boron Conc.

Max and Min Boron Conc.

Min Boron Concentration Min Boron Concentration Analytical Methods COLR Section 2.1 2.2 2.3 2.4 2.3 2.3 2.5 2.3 2.6 2.3 2.7 2.8 2.9 2.10 2.11 2.12 2.13 2.14 2.15 1.1 El Pag~e 9

9 9

11 9

911 9

15 9

15 20 21 24 26 26 26 28 28 6

The Selected Licensee Commitments that reference this report are listed below:

SLC Number Selected Licensing Commitment 16.9.14 Borated Water Source - Shutdown 16.9.11 16.9.7 Borated Water Source - Operating Standby Shutdown System COLR Parameter Borated Water Volume and Conc. for BAT/RWST Borated Water Volume and Conc. for BAT/RWST Standby Makeup Pump Water Supply COLR Section 2.16 2.17 2.18 El 29 30 30

MCEI-0400-232 Page 6 of 32 Revision 0 McGuire I Cycle 21 Core Operating Limits Report 1.1 Analytical Methods The analytical methods used to determine core operating limits for parameters identified in Technical Specifications and previously reviewed and approved by the NRC as specified in Technical Specification 5.6.5 are as follows.

1. WCAP-9272-P-A, "Westinghouse Reload Safety Evaluation Methodology," (W Proprietary).

Revision 0 Report Date: July 1985 Not Used for M1C21

2. WCAP-10054-P-A, "Westinghouse Small Break ECCS Evaluation Model using the NOTRUMP Code" (W Proprietary). -

Revision 0 Report Date: August 1985

3. WCAP-10266-P-A, "The 1981 Version Of Westinghouse Evaluation Model Using BASH CODE", (W Proprietary).

Revision 2 Report Date: March 1987 Not Used for MlC21

4. WCAP-12945-P-A, Volume 1 and Volumes 2-5, "Code Qualification Document for Best-Estimate Loss of Coolant Analysis," (W_ Proprietary).

Revision: Volume 1 (Revision 2) and Volumes 2-5 (Revision 1)

Report Date: March 1998

5. BAW-10168P-A, "B&W Loss-of-Coolant Accident Evaluation Model for Recirculating Steam Generator Plants," (B&W Proprietary).

Revision I SER Date: January 22, 1991 Revision 2 SER Dates: August 22, 1996 and November 26, 1996.

Revision 3 SER Date: June 15, 1994.

Not Used for M1C21

MCEI-0400-232 Page 7 of 32 Revision 0 McGuire 1 Cycle 21 Core Operating Limits Report 1.1 Analytical Methods (continued)

6. DPC-NE-3000-PA, "Thermal-Hydraulic Transient Analysis Methodology," (DPC Proprietary).

Revision 3 SER Date: September 24,2003

7. DPC-NE-300 1-PA, "Multidimensional Reactor Transients and Safety Analysis Physics Parameter Methodology," (DPC Proprietary).

Revision 0 Report Date: November 15, 1991 (Republished December 2000)

8. DPC-NE-3002-A, "FSAR Chapter 15 System Transient Analysis Methodology".

Revision 4 SER Date: April 6, 2001

9. DPC-NE-2004P-A, "Duke Power Company McGuire and Catawba Nuclear Stations Core Thermal-Hydraulic Methodology using VIPRE-O I," (DPC Proprietary).

Revision 2a SER Date: December 2008

10. DPC-NE-2005P-A, "Thermal Hydraulic Statistical Core Design Methodology," (DPC Proprietary).

Revision 4a SER Date: December 2008

11. DPC-NE-2008P-A, "Fuel Mechanical Reload Analysis Methodology Using TACO3," (DPC Proprietary).

Revision 0 SER Date: April 3; 1995 Not Used for M1C21

12. DPC-NE-2009-P-A, "Westinghouse Fuel Transition Report," (DPC Proprietary).

Revision 2a SER Date: July 2009

13. DPC-NE-1004A, "Nuclear Design Methodology Using CASMO-3/S IMULATE-3 P."

Revision 1 SER Date: April 26, 1996 Not Used for M1C21

MCEI-0400-232 Page 8 of 32 Revision 0 McGuire 1 Cycle 21 Core Operating Limits Report 1.1 Analytical Methods (continued)

14. DPC-NF-2010A, "Duke Power Company McGuire Nuclear Station Catawba Nuclear Station Nuclear Physics Methodology for Reload Design."

Revision 2 SER Date: June 24, 2003

15. DPC-NE-2011 PA, "Duke Power Company Nuclear Design Methodology for Core Operating Limits of Westinghouse Reactors," (DPC Proprietary).

Revision I SER Date: October 1, 2002

16. DPC-NE-1005-P-A, "Nuclear Design Methodology Using CASMO-4 / SIMULATE-3 MOX," (DPC Proprietary).

Revision 1 SER Date: November 12, 2008

MCEI-0400-232 Page 9 of 32 Revision 0 McGuire I Cycle 21 Core Operating Limits Report 2.0 Operating Limits The cycle-specific parameter limits for the specificitions listed in section 1.0 are presented in the following subsections. These limits have been developed using NRC approved methodologies specified in Section 1.1.

2.1 Requirements for Operational Mode 6 1

The following condition is required for operational mode 6.

2.1.1 The reactivity condition requirement for operational mode 6 is that klff must be less than, or equal to 0.95.

2.2 Reactor Core Safety Limits (TS.2.1.1) 2.2.1 The Reactor Core Safety Limits are shown in Figure 1.

2.3 Shutdown Margin - SDM (TS 3.1.1, TS 3.1.4, TS 3.1.5, TS 3.1.6 and TS 3.1.8) 2.3.1 ForTS 3.1.1, SDM shall be> 1.3% AK/K in MODE 2 with k-eff < 1.0 and in MODES 3 and4.

2.3.2 For TS 3.1.1, SDM shall be > 1.0% AK/K in MODE 5.

2.3.3 For TS 3.1.4, SDM shall be > 1.3% AK/K in MODES 1 and 2.

2.3.4 For TS 3.1.5, SDM shall be > 1.3% AK/K in MODE 1 and MODE 2 with any control bank not fully inserted.

2.3.5 ForTS 3.1.6, SDM shall be> 1.3% AK/K in MODE I and MODE 2 with K-eff> 1.0.

2.3.6 For TS 3.1.8, SDM shall be > 1.3% AK/K in MODE 2 during PHYSICS TESTS.

MCEI-0400-232 Page 10 of 32 Revision 0 McGuire 1 Cycle 21 Core Operating Limits Report Figure 1 Reactor'Core Safety Limits Four Loops in Operation 670 DO NOT OPERATE IN THIS AREA 660 650 640 t4*oo sia:

630 U 620 610 2100 psia" 6101%,.

S1945 psiia 600 590 ACCEPTABLE 580 0.0 0.2 0.4 0.6 0.8 1.0 12 Fraction of Rated Thermal Power

MCEI-0400-232 Page 11 of 32 Revision 0 McGuire 1 Cycle 21 Core Operating Limits Report 2.4 Moderator Temperature Coefficient - MTC (TS 3.1.3) 2.4.1 The Moderator Temperature Coefficient (MTC) Limits are:

The MTC shall be less positive than the upper limits shown in Figure 2. The BOC, ARO, HZP MTC shall be less positive than 0.7E-04 AK/KI°F.

The EOC, ARO, RTP MTC shall be less negative than the -4.3E-04 AKIK/0F lower MTC limit.

2.4.2 The 300 PPM MTC Surveillance Limit is:

The measured 300 PPM ARO, equilibrium RTP MTC shall be less negative than or equal to -3.65E-04 AK/K/0 F.

2.4.3 The 60 PPM MTC Surveillance Limit is:

The 60 PPM ARO, equilibrium RTP MTC shall be less negative than or equal to

-4.125E-04 AK/K/0F.

Where, BOC = Beginning of Cycle (Bumup corresponding to the most positive MTC.)

EOC = End of Cycle ARO = All Rods Out HZP = Hot Zero Power RTP = Rated Thermal Power PPM = Parts per million (Boron) 2.5 Shutdown Bank Insertion Limit (TS 3.1.5) 2.5.1 Each shutdown bank shall be withdrawn to at least 222 steps except under the conditions listed in Section 2.5.2. Shutdown banks are withdrawn in sequence and with no overlap.

2.5.2 Shutdown banks may be inserted to 219 steps withdrawn individually for up to 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> provided the plant was operated in steady state conditions near 100% FP prior to and during this exception.

MCEI-0400-232 Page 12 of 32 Revision 0 McGuire 1 Cycle 21 Core Operating Limits Report Figure 2 Moderator Temperature Coefficient Upper Limit Versus Power Level 1.0 0.9 Unacceptable Operation S

0.8 S

0.7 U

0.6 0.5 OA Acceptable Operation F-o 0,4 0

0.3 0.2 0.1 0

10 20 30 40 50 60 70 80 90 10(

Percent of Rated Thermal Power NOTE: Compliance with Technical Specification 3.1.3 may require rod withdrawal limits.

Refer to OP/l/A/6100/22 Unit I Data Book for details.

)

MCEI-0400-232 Page 13 of 32 Revision 0 McGuire 1 Cycle 21 Core Operating Limits Report Figure 3 Control Bank Insertion Limits Versus Percent Rated Thermal Power 231 220 200 180 P0 160 140 120 "100 0

60 0

80 0

o*40 0

20 0

0 10 20 30 40 50 60 70 80 90 100 Percent of Rated Thermal Power The Rod Insertion Limits (RIL) for Control Bank D (CD), Control Bank C (CC), and Control Bank B (CB) can be calculated by:

Bank CD RIL = 2.3(P) - 69 (30 < P < 100)

Bank CCRIL = 2.3(P) +47 (0<P <76.1) for CCRIL = 222 (76.1 <P<100}

Bank CB RIL = 2.3(P) +163 (0 < P < 25.7} for CB RIL = 222 (25.7 < P < 100}

where P = %Rated Thermal Power NOTES; (1) Compliance with Technical Specification 3.1.3 may require rod withdrawal limits.

Refer to OP/l/A/6100/22 Unit 1 Data Book for details.

(2) Anytime any shutdown bank or control banks A, B, or C are inserted below 222 steps withdrawn, control bank D insertion is limited to > 200 steps withdrawn (see Sections 2.5.2 and 2.6.2)

MCEI-0400-232 Page 14 of 32 Revision 0 McGuire 1 Cycle 21 Core Operating Limits Report Table 1 RCCA Withdrawal Steps and Sequence Fully Withdrawn at 222 Steps Control Control Control Control BankA Bank B Bank C BankD Fully Withdrawn at 223 Steps Control Control Control Control Bank A Bank B Bank C Bank D 0 Start 0

0 0

116 0 Start 0

0 222 Stop 106 0

0 222 116 0 Start 0

222 222 Stop 106 0

222 222 116 0 Start 222 222 222 Stop 106 Fully Withdrawn at 224 Steps

.Control Control Control Control BankA BankB BankC BankD 0 Start 0

0 0

116 0 Start 0

0 223 Stop 107 0

0 223 116 0 Stat 0

223 223 Stop 107 0

223 223 116 0 Start 223 223 223 Stop 107 Fully Withdrawn at 225 Steps Control Control Control Control Bank A Bank B Bank C Bank D 0 Start 0

0 0

116 0 Start 0

.0 224 Stop 108 0

0 224 116 0 Start 0

224 224 Stop 108 0

224 224 116 0 Start 224 224 224 Stop 108 Fully Withdrawn at 226 Steps Control Control Control Control BankA BankB BankC BankD 0 Start 0

0 0

116 0 Start

0.

0 225 Stop 109 0

0 225 116 0 Start 0

225 225 Stop 109 0

225 225 116 0 Start 225 225 225 Stop 109 Fully Withdrawn at 227 Steps Control Control Control Control Bank A Bank B Bank C Bank D 0 Start 0

0 0

116 0 Start 0

0 226 Stop 110 0

0 226 116 0 Start 0

226 226 Stop 110 0

226 226 116 0 Start 226 226 2 2 6 Stop 110 Fully Withdrawn at 228 Steps Control Control Control Control BankA BankB BankC BankD 0 Start 0

0 0

116 0 Start 0

0 228 Stop 112 0

0 228 116 0 Start 0

228 228 Stop 112 0

228 228 116 0 Start 228 228 228 Stop 112 Fully Withdrawn at 230 Steps Control Control Control Control BankA BankB BankC Bank D 0 Start 0

0 0

116 0 Start 0

0 230 Stop 114 0

0 230 116 0 Start 0

230 230 Stop 114 0

230 230 116 0 Start 230 230 230 Stop 114 0 Start 0

0 0

116 0 Start 0

0 227 Stop 111 0

0 227 116 0 Start 0

227 227 Stop III 0

227 227 116 0 Start 227 227 227 Stop 111 Fully Withdrawn at 229 Steps Control Control Control Control BankA Bank B Bank C BankD 0 Start 0

0 0

116 0 Start 0

0 229 Stop 113 0

0 229 116 0 Start 0

229 229 Stop 113 0

229 229 116 0 Start 229 229 229 Stop 113 Fully Withdrawn at 231 Steps Control Control Control Control BankA Bank B Bank C BankD 0 Start 0

0 0

116 0 Start 0

0 231 Stop 115 0

0 231 116 0 Start 0

231 231 Stop 115 0

231 231 116 0 Start 231 231 23.1 Stop 115

MCEI-0400-232 Page 15 of 32 Revision 0 McGuire 1 Cycle 21 Core Operating Limits Report 2.6 Control Bank Insertion Limits (TS 3.1.6) 2.6.1 Control banks shall be within the insertion, sequence, and overlap limits shown in Figure 3 except under the conditions listed in Section 2.6.2. Specific control bank withdrawal and overlap limits as a function of the fully withdrawn position are shown in Table 1.

2.6.2 Control banks A, B, or C may be inserted to 219 steps withdrawn individually for up to 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> provided the plant was operated in steady state conditions near 100% FP prior to and during this exception.

2.7 Heat Flux Hot Channel Factor - FQ(X,Y,Z) (TS 3.2.1) 2.7.1 FQ(X,Y,Z) steady-state limits are defined by the following relationships:

F:R *K(Z)/P for P > 0.5 F RTP *K(Z)/0.5 for P < 0.5 Q

where, P = (Thermal Power)/(Rated Power)

Note: The measured FQ(X,Y,Z) shall be increased by 3% to account for manufacturing tolerances and 5% to account for measurement uncertainty when comparing against LCO limits. The manufacturing tolerance and measurement uncertainty are implicitly included in the FQ surveillance limits as defined in COLR Sections 2.7.5 and 2.7.6.

2.7.2 F ITP = 2.60 x K(BU)

-Q 2.7.3 K(Z) is the normalized FQ(X,Y,Z) as a function of core height. The K(Z) function for Westinghouse RFA fuel is provided in Figure 4.

2.7.4 K(BU) is the normalized FQ(X,Y,Z) as a function of burnup. K(BU) for Westinghouse RFA fuel is 1.0 for all burnups.

The following parameters are required for core monitoring per the Surveillance Requirements of Technical Specification 3.2.1:

2.7.5 F

z

= FQ(X,Y,Z)

  • MQ(X,Y,Z)

FQ(XYZ)

  • UMT
  • TILT

MCEI-0400-232 Page 16 of 32 Revision 0 McGuire 1 Cycle 21 Core Operating Limits Report where:

FoL (X,Y,Z)OP EQ9 (X,Y,Z)

MQ(X,Y,Z)

=

Cycle dependent maximum allowable design peaking factor that ensures that the FQ(X,Y,Z) LOCA limit is not exceeded for operation within the AFD, RIL, and QPTR limits. FL (X,Y,Z)°P includes allowances for calculational and measurement uncertainties.

Design power distribution for FQ. FQ9 (X,Y,Z) is provided in Appendix A-1 for normal operating conditions and in Appendix Table A-4 for power escalation testing during initial startup operation.

Margin remaining in core location X,Y,Z to the LOCA limit in the transient power distribution. MQ(X,Y,Z) is provided in Appendix Table A-1 for normal operating conditions and in Appendix Table A-4 for power escalation testing during initial startup operation.

UMT = Total Peak Measurement Uncertainty. (UMT = 1.05)

MT = Engineering Hot Channel Factor. (MT = 1.03)

TILT = Peaking penalty that accounts for the peaking increase from an allowable quadrant power tilt ratio of 1.02. (TILT = 1.035) 2.7.6 FQ(X,Y,Z)RPs-FQ(X,Y,Z)

  • Mc(X,Y,Z)

UMT

  • TILT where:

L FQ(X,Y,Z)RPS=

Cycle dependent maximum allowable design peaking factor that ensures that ensures the FQ(XY,Z) Centerline Fuel Melt (CFM) limit is not exceeded for operation within the AFD, RIL, and QPTR limits. [FQ(X,Y,Z)]s includes allowances for calculational and measurement uncertainties.

D Design power distributions for FQ. FQ(X,Y,Z) is provided in Appendix Table A-I for normal operating conditions and in Appendix Table A-4 for power escalation testing during initial startup operation.

FQ(XYZ)-

MCEI-0400-232 Page 17 of 32 Revision 0 MeGuire I Cycle 21 Core Operating Limits Report Mc(X,Y,Z) =

Margin remaining to the CFM limit in core location X,Y,Z from the transient power distribution. MC(X,Y,Z) is provided in Appendix Table A-2 for normal operating conditions and in Appendix Table A-5 for power escalation testing during initial startup operation.

UMT = Total Peak Measurement Uncertainty (UMT = 1.05)

MT = Engineering Hot Channel Factor (MT = 1.03)

TILT = Peaking penalty that accounts for the peaking increase for an allowable quadrant power tilt ratio of 1.02. (TILT = 1.035) 2.7.7 KSLOPE

- 0.0725 where:

KSLOPE is the adjustment to the K1 value from OTAT trip setpoint required to L

RPS compensate for each 1% that FQ" (X,Y,Z) exceeds Fd (X,Y,Z) 2.7.8 FQ(X,Y,Z) penalty factors for Technical Specification Surveillances 3.2.1.2 and 3.2.1.3 are provided in Table 2.

MCEI-0400-232 Page 18 of 32 Revision 0 McGuire I Cycle 21 Core Operating Limits Report Figure 4 K(Z), Normalized FQ(X,Y,Z) as a Function of Core Height for Westinghouse RFA Fuel 1.200 (0.0, 1.00)

(4.0, 1.00) 1.000 (12.0,0.9615)

(4.0, 0.9615) 0.800 0.600,..

0.400 Core Height (ft)

K(Z) 0.0 1.000 0.200

<4 1.000

>4 0.9615 12.0 0.9615 0.000 i

i I

0.0 2.0 4.0 6.0 8.0 10.0 12.0 Core Height (ft)

MCEI-0400-232 Page 19 of 32 Revision 0 McGuire 1 Cycle 21 Core Operating Limits Report Table 2 FQ(X,Y,Z) and FAH(X,Y) Penalty Factors For Technical Specification Surveillances 3.2.1.2, 3.2.1.3 and 3.2.2.2 Burnup (EFPD) 0 4

12 25 50 75 100 125 150 175 200 225 250 275 300 325 350 375 400 425 450 475 484 494 509 524 FQ(X,Y,Z)

Penalty Factor (%)

2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 FAH(X,Y,Z)

Penalty Factor (%)

2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 Note:

Linear interpolation is adequate for intermediate cycle burnups. All cycle burnups outside of the range of the table shall use a 2% penalty factor for both FQ(X,Y,Z) and FAH(X,Y) for compliance with the Technical Specification Surveillances 3.2.1.2, 3.2.1.3 and 3.2.2.2.

MCEI-0400-232 Page 20 of 32 Revision 0 McGuire 1 Cycle 21 Core Operating Limits Report 2.8 Nuclear Enthalpy Rise Hot Channel Factor - FAH(X,Y) (TS 3.2.2)

The FAH steady-state limits referred to in Technical Specification 3.2.2 is defined by the following relationship.

2.8. (X, Y)

= MARP (XY)

  • 1.0 (10 P)]

where:

FkH (X, Y)Lco is defined as the steady-state, maximum allowed radial peak and includes allowances for calculation-measurement uncertainty.

MARP(X,Y)

Cycle-specific operating limit Maximum Allowable Radial Peaks.

MARP(X,Y) radial peaking limits are provided in Table 3.

.Thermal Power Rated Thermal Power.

RRH = Thermal Power reduction required to compensate for each 1% that the measured radial peak, FH (X,Y), exceeds the limit. (RRH = 3.34 (0.0 < P <

1.0))

The following parameters are required for core monitoring per the Surveillance requirements of Technical Specification 3.2.2.

2.8.2 FL(X,Y)SUgV F- (X,Y)xMm(X,Y)

UMR x TILT where:

L SUJRV FP (X,Y)

=

Cycle dependent maximum allowable design peaking factor that ensures that the FAH(XY) limit is not exceeded for operation within the AFD, RIL, and QPTR limits. FL (X,Y)SRV includes allowances for calculational and measurement uncertainty.

MCEI-0400-232 Page 21 of 32 Revision 0 McGuire I Cycle 21 Core Operating Limits Report D

D FA (X,Y) = Design radial power distribution for F. FA (X,Y) is provided in Appendix Table A-3 for normal operation and in Appendix Table A-6 for power escalation testing during initial startup operation.

MA(X,Y) = The margin remaining in core location X,Y relative to the Operational DNB limits in the transient power distribution.

MAH(X,Y) is provided in Appendix Table A-3 for normal operation and in Appendix Table A-6 for power escalation testing during initial startup operation.

UMR = Uncertainty value for measured radial peaks. UMR is set to 1.0 since a factor of 1.04 is implicitly included in the variable MAH(X,Y).

TILT = Peaking penalty that accounts for the peaking increase for an allowable quadrant power tilt ratio of 1.02. (TILT = 1.035).

2.8.3 RRH 3.34 where:

RRH = Thermal power reduction required to compensate for each 1% that the measured radial peak, F1 (X,Y) exceeds its limit. (0 < P < 1.0) 2.8.4 TRH = 0.04 where:

TRH = Reduction in OTAT K1 setpoint required to compensate for each 1% that the measured radial peak, FH (X,Y) exceeds its limit.

2.8.5 FAH(XY) penalty factors for Technical Specification Surveillance 3.2.2.2 are provided in Table 2.

2.9 Axial Flux Difference - AFD (TS 3.2.3) 2.9.1 The Axial Flux Difference (AFD) Limits are provided in Figure 5.

MCEI-0400-232 Page 22 of 32 Revision 0 McGuire 1 Cycle 21 Core Operating Limits Report Table 3 Maximum Allowable Radial Peaks (MARPs)

(Applicable for RFA Fuel)

Core Axial Peak Ht (ft.)

LO0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.1 3.0 3.25 0.12 1.809 1.855 1.949 1.995 1.974 2.107 2.050 2.009 1.933 1.863 1.778 1.315 1.246 1.2 1.810 1.854 1.940 1.995 1.974 2.107 2.019 1.978 1.901 1.831 1.785 1.301 1.224 2.4 1.809 1.853 1.931 1.978 1.974 2.074 1.995 1.952 1.876 1.805 1.732 1.463 1.462 3.6 1.810 1.851 1.920 1.964 1.974 2.050 1.966 1.926 1.852 1.786 1.700 1.468 1.387 4.8 1.810 1.851 1.906 1.945 1.974 2.006 1.944 1.923 1.854 1.784 1.671 1.299 1.258 6.0 1.810 1.851 1.892 1.921 1.946 1.934 1.880 1.863 1.802 1.747 1.671 1.329 1.260 7.2 1.807 1.844 1.872 1.893 1.887 1.872 1.809 1.787 1.733 1.681 L'598 1.287 1.220 8.4 1.807 1.832 1.845 1.857 1.816 1.795 1.736.

1.709 1.654 1.601 1.513

1.218 1.158 9.6 1.807 1.810 1.809 1.791 1.738 1.718 1.657 1.635 1.581 1.530 1.444 1.143 1.091 10.8 1.798 1.787 1.761 1.716 1.654 1.632 1.574 1.557 1L509 1.462 1.383 1.101 1.047 11.4 1.789 1.765 1.725 1.665 1.606 1.583 1.529 1.510 1.464 1.422 1.346 1.067 1.014

MCEI-0400-232 Page 23 of 32 Revision 0 McGuire 1 Cycle 21 Core Operating Limits Report Figure 5 Percent of Rated Thermal Power Versus Percent Axial Flux Difference Limits L.

4, 0

2 L.

4, 4,

4, 4,

-50

-40

-30

-20

-10 0

10 20 30 40 50 Axial Flux Difference (% Delta 1)

NOTE: Compliance with Technical Specification 3.2.1 may require more restrictive AFD limits.

Refer to OP/1/A/6100/22 Unit 1 Data Book for more details.

MCEI-0400-232 Page 24 of 32 Revision 0 McGuire 1 Cycle 21 Core Operating Limits Report 2.10 Reactor Trip System Instrumentation Setpoints (TS 3.3.1) Table 3.3.1-1 2.10.1 Overtemperature AT Setpoint Parameter Values Parameter Value Nominal Tavg at RTP Nominal RCS Operating Pressure Overtemperature AT reactor trip setpoint Overtemperature AT reactor trip heatup setpoint penalty coefficient OvertemperatureAT reactor trip depressurization setpoint penalty coefficient Time constants utilized in the lead-lag compensator for AT Time constant utilized in the lag compensator for AT Time constants utilized in the lead-lag compensator for Tayg Time constant utilized in the measured Tayg lag compensator fl(Al) "positive" breakpoint fl (AD "negative" breakpoint fl(AD) "positive" slope fl(Al) "negative" slope T' < 585.10 F P' = 2235 psig KI <1.1978 K2 = 0.0334/°F K3 0.001601/psi c > 8 sec.

T2 < 3 sec.

r3 < 2 sec.

T4 > 28 sec.

r5 < 4 see.

T6 < 2 sec.

= 19.0 %AI

= N/A*

= 1.769 %AT0/ %Al

= N/A*

The fl(AI) negative breakpoints and slopes for OTAT are less restrictive than the OPAT f2(AI) negative breakpoint and slope. Therefore, during a transient which challenges the negative imbalance limits the OPAT f2(AI) limits will result in a reactor trip before the OTAT fl(Al) limits are reached. This makes implementation of an OTAT fl(Al) negative breakpoint and slope unnecessary.

MCEI-0400-232 Page 25 of 32 Revision 0 McGuire 1 Cycle 21 Core Operating Limits Report 2.10.2 Overpower AT Setpoint Parameter Values Parameter Nominal Tavg at RTP Overpower AT reactor trip setpoint Overpower AT reactor trip Penalty Overpower AT reactor trip heatup setpoint penalty coefficient Time constants utilized in the lead-lag compensator for AT Time constant utilized in the lag compensator for AT Time constant utilized in the measured Tavg lag compensator Time constant utilized in the rate-lag controller for Tayg f2(AI) "positive" breakpoint f2(AI) "negative" breakpoint f2(AI) "positive" slope f2(AI) "negative" slope Value T" < 585.1 0F K4 < 1.0864 K5 = 0.02/'F for increasing Tavg K5 = 0.0 for decreasing Tavg K6 = 0.001179/'F for T > T" K6 = 0.0 for T<T" 1 > 8 sec.

T2 < 3 sec.

¶3 <2 sec.

r6 < 2 sec.

t7 > 5 sec.

= 35.0%AI

= -35.0 %AI

= 7.0 %ATo %/,1

= 7.0 %AT0/%AI

MCEI-0400-232 Page 26 of 32 Revision 0 McGuire 1 Cycle 21 Core Operating Limits Report 2.11 RCS Pressure, Temperature and Flow Limits for DNB (TS 3.4.1) 2.11.1 The RCS pressure, temperature and flow limits for DNB are shown in Table 4.

2.12 Accumulators (TS 3.5.1) 2.12.1 Boron concentration limits during MODES 1 and 2, and MODE 3 with RCS pressure >1000 psi:

Parameter Accumulator minimum boron concentration.

Accumulator maximum boron concentration.

Limit 2,475 ppm 2,875 ppm 2.13 Refueling Water Storage Tank - RWST (TS 3.5.4):

2.13.1 Boron concentration limits during MODES 1, 2, 3, and 4:

Parameter RWST minimum boron concentration.

RWST maximum boron concentration.

Limit 2,675 ppm 2,875 ppm

MCEI-0400-232 Page 27 of 32 Revision 0 McGuire 1 Cycle 21 Core Operating Limits Report Table 4 Reactor Coolant System DNB Parameters No. Operable PARAMETER INDICATION CHANNELS LIMITS

1. Indicated RCS Average Temperature meter 4

< 587.2 OF meter 3

< 586.9 OF computer 4

< 587.7 OF computer 3

< 587.5 OF

2. Indicated Pressurizer Pressure meter 4

> 2219.8 psig meter 3

>2222.1 psig computer 4

> 2215.8 psig computer 3

> 2217.5 psig

3. RCS Total Flow Rate

> 390,000 gpm*

  • Note: The RCS minimum coolant flow rate assumed in the licensing analyses for the MIC21 core is 388,000 gpm. However, the flow is set at 390,000 gpm, which is conservative

MCEI-0400-232 Page 28 of 32 Revision 0 McGuire 1 Cycle 21 Core Operating Limits Report 2.14 Spent Fuel Pool Boron Concentration (TS 3.7.14) 2.14.1 Minimum boron concentration limit for the spent fuel pool. Applicable when fuel assemblies are stored in the spent fuel pool.

Parameter Limit Spent fuel pool minimum boron concentration.

2,675 ppm 2.15 Refueling Operations - Boron Concentration (TS 3.9.1).

2.15.1 Minimum boron concentration limit for the filled portions of the Reactor Coolant System, refueling canal, and refueling cavity for MODE 6 conditions. The minimum boron concentration limit and plant refueling procedures ensure that the Keff of the core will remain within the MODE 6 reactivity requirement of Keff < 0.95.

Parameter Limit Minimum Boron concentration of the Reactor Coolant System, the refueling canal, and the refueling cavity.

2,675 ppm

MCEI-0400-232 Page 29 of 32 Revision 0 McGuire 1 Cycle 21 Core Operating Limits Report 2.16 Borated Water Sources - Shutdown (SLC 16.9.14) 2.16.1 Volume and boron concentrations for the Boric Acid Tank (BAT) and the Refueling Water Storage Tank (RWST) during MODE 4 with any RCS cold leg temperature

< 300 'F and MODES 5 and 6.

Parameter Limit BAT minimum contained borated water volume 10,599 gallons 13.6% Level Note: When cycle burnup is > 455 EFPD, Figure 6 may be used to determine the required BAT minimum level.

BAT minimum boron concentration BAT minimum water volume required to maintain SDM at 7,000 ppm RWST minimum contained borated water volume RWST minimum boron concentration RWST minimum water volume required to maintain SDM at 2,675 ppm 7,000 ppm 2,300 gallons 47,700 gallons 41 inches 2,675 ppm 8,200 gallons

MCEI-0400-232 Page 30 of 32 Revision 0 McGuire I Cycle 21 Core Operating Limits Report 2.17 Borated Water Sources - Operating (SLC 16.9.11) 2.17.1 Volume and boron concentrations for the Boric Acid Tank (BAT) and the Refueling Water Storage Tank (RWST) during MODES 1, 2, 3, and MODE 4 with all RCS cold leg temperatures > 300'F.

Parameter Limit BAT minimum contained borated water volume 22,049 gallons 38.0% Level Note: When cycle burnup is > 455 EFPD, Figure 6 may be used to determine the required BAT minimum level.

BAT minimum boron concentration 7,000 ppm BAT minimum water volume required to maintain SDM at 7,000 ppm RWST minimum contained borated water volume RWST minimum boron concentration RWST maximum boron concentration (TS 3.5.4)

RWST minimum water volume required to maintain SDM at 2,675 ppm 13,750 gallons 96,607 gallons 103.6 inches 2,675 ppm 2875 ppm 57,107 gallons 2.18 Standby Shutdown System - (SLC-16.9.7) 2.18.1 Minimum boron concentration limit for the spent fuel pool required for Standby Makeup Pump Water Supply. Applicable for MODES 1, 2, and 3.

Parameter Limit Spent fuel pool minimum boron concentration for TR 16.9.7.2.

2,675 ppm

MCEI-0400-232 Page 31 of 32 Revision 0 McGuire 1 Cycle 21 Core Operating Limits Report Figure 6 Boric Acid Storage Tank Indicated Level Versus RCS Boron Concentration (Valid When Cycle Burnup is > 455 EFPD)

This figure includes additional volumes listed in SLC 16.9.14 and 16.9.11 40.0 RCS Boron 35.0 Concentraton BAT Level (ppm)

(%level) 0 < 300 37.0 300 <500 i

33.0

-0.0.

500 <700-28.0 700<1000 23.0

.1000 <'1300 13.6

_ 25.0 1300 8.7 20.0 I Acceptable m 15.0 10.0 Unacceptable Operation ]

5.0 0.0 0

200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 RCS Boron Concentration (ppmb)

MCEI-0400-232 Page 32 of 32 Revision 0 McGuire 1 Cycle 21 Core Operating Limits Report NOTE: Appendix A contains power distribution monitoring factors used in Technical Specification Surveillance. This data was generated in the McGuire I Cycle 21 Maneuvering Analysis calculation file, MCC-1553.05-00-0512. Due to the size of the monitoring factor data, Appendix A is controlled electronically within Duke and is not included in the Duke internal copies of the COLR. The Plant Nuclear Engineering Section will control this information via computer file(s) and should be contacted if there is a need to access this information.

Appendix A is included in the COLR copy transmitted to the NRC.