ML042680149
ML042680149 | |
Person / Time | |
---|---|
Site: | Yankee Rowe |
Issue date: | 08/05/2004 |
From: | Yankee Atomic Electric Co |
To: | NRC/FSME |
References | |
-RFPFR | |
Download: ML042680149 (171) | |
Text
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:06 Page 1 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Ag108m-concrete-DCGL.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary ... 2 Site-Specific Parameter Summary .......................... 3 Summary of Pathway Selections ............................ 6 Contaminated Zone and Total Dose Summary ................. 7 Total Dose Components Time = 0.000E+00 .................................... 8 Time = 1.000E+00 .................................... 9 Time = 3.000E+00 .................................... 10 Time = 1.000E+01 .................................... 11 Time = 3.000E+01 .................................... 12 Time = 1.000E+02 .................................... 13 Time = 3.000E+02 .................................... 14 Time = 1.000E+03 .................................... 15 Dose/Source Ratios Summed Over All Pathways .............. 16 Single Radionuclide Soil Guidelines ...................... 16 Dose Per Nuclide Summed Over All Pathways ................ 17 Soil Concentration Per Nuclide ........................... 17
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:06 Page 2 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Ag108m-concrete-DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary File: YR Concrete 0 Current Parameter Menu Parameter Value Default Name B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 Ag-108m+D 2.830E-04 2.830E-04 DCF2( 1)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Ag-108m+D 7.620E-06 7.620E-06 DCF3( 1)
D-34 Food transfer factors:
D-34 Ag-108m+D, plant/soil concentration ratio, dimensionless 1.470E-05 1.500E-01 RTF( 1,1)
D-34 Ag-108m+D, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 2.000E-03 3.000E-03 RTF( 1,2)
D-34 Ag-108m+D, milk/livestock-intake ratio, (pCi/L)/(pCi/d) 9.570E-03 2.500E-02 RTF( 1,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Ag-108m+D, fish 5.000E+00 5.000E+00 BIOFAC( 1,1)
D-5 Ag-108m+D, crustacea and mollusks 7.700E+02 7.700E+02 BIOFAC( 1,2)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:06 Page 3 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Ag108m-concrete-DCGL.RAD Site-Specific Parameter Summary 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R011 Area of contaminated zone (m**2) 5.020E+03 1.000E+04 --- AREA R011 Thickness of contaminated zone (m) 3.800E+00 2.000E+00 --- THICK0 R011 Length parallel to aquifer flow (m) 8.000E+01 1.000E+02 --- LCZPAQ R011 Basic radiation dose limit (mrem/yr) 2.500E+01 2.500E+01 --- BRDL R011 Time since placement of material (yr) 0.000E+00 0.000E+00 --- TI R011 Times for calculations (yr) 1.000E+00 1.000E+00 --- T( 2)
R011 Times for calculations (yr) 3.000E+00 3.000E+00 --- T( 3)
R011 Times for calculations (yr) 1.000E+01 1.000E+01 --- T( 4)
R011 Times for calculations (yr) 3.000E+01 3.000E+01 --- T( 5)
R011 Times for calculations (yr) 1.000E+02 1.000E+02 --- T( 6)
R011 Times for calculations (yr) 3.000E+02 3.000E+02 --- T( 7)
R011 Times for calculations (yr) 1.000E+03 1.000E+03 --- T( 8)
R011 Times for calculations (yr) not used 0.000E+00 --- T( 9)
R011 Times for calculations (yr) not used 0.000E+00 --- T(10)
R012 Initial principal radionuclide (pCi/g): Ag-108m 1.000E+00 0.000E+00 --- S1( 1)
R012 Concentration in groundwater (pCi/L): Ag-108m not used 0.000E+00 --- W1( 1)
R013 Cover depth (m) 0.000E+00 0.000E+00 --- COVER0 R013 Density of cover material (g/cm**3) not used 1.500E+00 --- DENSCV R013 Cover depth erosion rate (m/yr) not used 1.000E-03 --- VCV R013 Density of contaminated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSCZ R013 Contaminated zone erosion rate (m/yr) 8.500E-04 1.000E-03 --- VCZ R013 Contaminated zone total porosity 3.000E-01 4.000E-01 --- TPCZ R013 Contaminated zone field capacity 7.000E-02 2.000E-01 --- FCCZ R013 Contaminated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+01 --- HCCZ R013 Contaminated zone b parameter 9.750E-01 5.300E+00 --- BCZ R013 Average annual wind speed (m/sec) 2.030E+00 2.000E+00 --- WIND R013 Humidity in air (g/m**3) not used 8.000E+00 --- HUMID R013 Evapotranspiration coefficient 6.250E-01 5.000E-01 --- EVAPTR R013 Precipitation (m/yr) 1.200E+00 1.000E+00 --- PRECIP R013 Irrigation (m/yr) 4.350E-01 2.000E-01 --- RI R013 Irrigation mode overhead overhead --- IDITCH R013 Runoff coefficient 6.000E-01 2.000E-01 --- RUNOFF R013 Watershed area for nearby stream or pond (m**2) 7.770E+05 1.000E+06 --- WAREA R013 Accuracy for water/soil computations 1.000E-03 1.000E-03 --- EPS R014 Density of saturated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSAQ R014 Saturated zone total porosity 2.800E-01 4.000E-01 --- TPSZ R014 Saturated zone effective porosity 2.100E-01 2.000E-01 --- EPSZ R014 Saturated zone field capacity 7.000E-02 2.000E-01 --- FCSZ R014 Saturated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+02 --- HCSZ R014 Saturated zone hydraulic gradient 1.000E-01 2.000E-02 --- HGWT R014 Saturated zone b parameter 9.750E-01 5.300E+00 --- BSZ R014 Water table drop rate (m/yr) 1.000E-03 1.000E-03 --- VWT R014 Well pump intake depth (m below water table) 1.000E+01 1.000E+01 --- DWIBWT R014 Model: Nondispersion (ND) or Mass-Balance (MB) MB ND --- MODEL R014 Well pumping rate (m**3/yr) 2.500E+02 2.500E+02 --- UW R015 Number of unsaturated zone strata 0 1 --- NS
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:06 Page 4 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Ag108m-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R016 Distribution coefficients for Ag-108m R016 Contaminated zone (cm**3/g) 6.500E+03 0.000E+00 --- DCNUCC( 1)
R016 Saturated zone (cm**3/g) 0.000E+00 0.000E+00 --- DCNUCS( 1)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 9.021E-06 ALEACH( 1)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 1)
R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 --- INHALR R017 Mass loading for inhalation (g/m**3) 2.330E-05 1.000E-04 --- MLINH R017 Exposure duration 3.000E+01 3.000E+01 --- ED R017 Shielding factor, inhalation 5.500E-01 4.000E-01 --- SHF3 R017 Shielding factor, external gamma 3.980E-01 7.000E-01 --- SHF1 R017 Fraction of time spent indoors 6.571E-01 5.000E-01 --- FIND R017 Fraction of time spent outdoors (on site) 1.181E-01 2.500E-01 --- FOTD R017 Shape factor flag, external gamma 1.000E+00 1.000E+00 >0 shows circular AREA. FS R017 Radii of shape factor array (used if FS = -1):
R017 Outer annular radius (m), ring 1: not used 5.000E+01 --- RAD_SHAPE( 1)
R017 Outer annular radius (m), ring 2: not used 7.071E+01 --- RAD_SHAPE( 2)
R017 Outer annular radius (m), ring 3: not used 0.000E+00 --- RAD_SHAPE( 3)
R017 Outer annular radius (m), ring 4: not used 0.000E+00 --- RAD_SHAPE( 4)
R017 Outer annular radius (m), ring 5: not used 0.000E+00 --- RAD_SHAPE( 5)
R017 Outer annular radius (m), ring 6: not used 0.000E+00 --- RAD_SHAPE( 6)
R017 Outer annular radius (m), ring 7: not used 0.000E+00 --- RAD_SHAPE( 7)
R017 Outer annular radius (m), ring 8: not used 0.000E+00 --- RAD_SHAPE( 8)
R017 Outer annular radius (m), ring 9: not used 0.000E+00 --- RAD_SHAPE( 9)
R017 Outer annular radius (m), ring 10: not used 0.000E+00 --- RAD_SHAPE(10)
R017 Outer annular radius (m), ring 11: not used 0.000E+00 --- RAD_SHAPE(11)
R017 Outer annular radius (m), ring 12: not used 0.000E+00 --- RAD_SHAPE(12)
R017 Fractions of annular areas within AREA:
R017 Ring 1 not used 1.000E+00 --- FRACA( 1)
R017 Ring 2 not used 2.732E-01 --- FRACA( 2)
R017 Ring 3 not used 0.000E+00 --- FRACA( 3)
R017 Ring 4 not used 0.000E+00 --- FRACA( 4)
R017 Ring 5 not used 0.000E+00 --- FRACA( 5)
R017 Ring 6 not used 0.000E+00 --- FRACA( 6)
R017 Ring 7 not used 0.000E+00 --- FRACA( 7)
R017 Ring 8 not used 0.000E+00 --- FRACA( 8)
R017 Ring 9 not used 0.000E+00 --- FRACA( 9)
R017 Ring 10 not used 0.000E+00 --- FRACA(10)
R017 Ring 11 not used 0.000E+00 --- FRACA(11)
R017 Ring 12 not used 0.000E+00 --- FRACA(12)
R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 --- DIET(1)
R018 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 --- DIET(2)
R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 --- DIET(3)
R018 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 --- DIET(4)
R018 Fish consumption (kg/yr) 2.060E+01 5.400E+00 --- DIET(5)
R018 Other seafood consumption (kg/yr) 9.000E-01 9.000E-01 --- DIET(6)
R018 Soil ingestion rate (g/yr) 1.826E+01 3.650E+01 --- SOIL R018 Drinking water intake (L/yr) 4.785E+02 5.100E+02 --- DWI
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:06 Page 5 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Ag108m-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R018 Contamination fraction of drinking water 1.000E+00 1.000E+00 --- FDW R018 Contamination fraction of household water not used 1.000E+00 --- FHHW R018 Contamination fraction of livestock water 1.000E+00 1.000E+00 --- FLW R018 Contamination fraction of irrigation water 1.000E+00 1.000E+00 --- FIRW R018 Contamination fraction of aquatic food 1.000E+00 5.000E-01 --- FR9 R018 Contamination fraction of plant food 1.000E+00 -1 --- FPLANT R018 Contamination fraction of meat 1.000E+00 -1 --- FMEAT R018 Contamination fraction of milk 1.000E+00 -1 --- FMILK R019 Livestock fodder intake for meat (kg/day) 2.710E+01 6.800E+01 --- LFI5 R019 Livestock fodder intake for milk (kg/day) 6.320E+01 5.500E+01 --- LFI6 R019 Livestock water intake for meat (L/day) 5.060E+01 5.000E+01 --- LWI5 R019 Livestock water intake for milk (L/day) 6.000E+01 1.600E+02 --- LWI6 R019 Livestock soil intake (kg/day) 5.000E-01 5.000E-01 --- LSI R019 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.000E-04 --- MLFD R019 Depth of soil mixing layer (m) 2.300E-01 1.500E-01 --- DM R019 Depth of roots (m) 2.050E+00 9.000E-01 --- DROOT R019 Drinking water fraction from ground water 1.000E+00 1.000E+00 --- FGWDW R019 Household water fraction from ground water not used 1.000E+00 --- FGWHH R019 Livestock water fraction from ground water 1.000E+00 1.000E+00 --- FGWLW R019 Irrigation fraction from ground water 1.000E+00 1.000E+00 --- FGWIR R19B Wet weight crop yield for Non-Leafy (kg/m**2) 1.750E+00 7.000E-01 --- YV(1)
R19B Wet weight crop yield for Leafy (kg/m**2) 2.889E+00 1.500E+00 --- YV(2)
R19B Wet weight crop yield for Fodder (kg/m**2) 1.887E+00 1.100E+00 --- YV(3)
R19B Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 --- TE(1)
R19B Growing Season for Leafy (years) 1.230E-01 2.500E-01 --- TE(2)
R19B Growing Season for Fodder (years) 8.200E-02 8.000E-02 --- TE(3)
R19B Translocation Factor for Non-Leafy 1.000E-01 1.000E-01 --- TIV(1)
R19B Translocation Factor for Leafy 1.000E+00 1.000E+00 --- TIV(2)
R19B Translocation Factor for Fodder 1.000E+00 1.000E+00 --- TIV(3)
R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RDRY(1)
R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 --- RDRY(2)
R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RDRY(3)
R19B Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RWET(1)
R19B Wet Foliar Interception Fraction for Leafy 5.800E-01 2.500E-01 --- RWET(2)
R19B Wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RWET(3)
R19B Weathering Removal Constant for Vegetation 3.300E+01 2.000E+01 --- WLAM C14 C-12 concentration in water (g/cm**3) not used 2.000E-05 --- C12WTR C14 C-12 concentration in contaminated soil (g/g) not used 3.000E-02 --- C12CZ C14 Fraction of vegetation carbon from soil not used 2.000E-02 --- CSOIL C14 Fraction of vegetation carbon from air not used 9.800E-01 --- CAIR C14 C-14 evasion layer thickness in soil (m) not used 3.000E-01 --- DMC C14 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 --- EVSN C14 C-12 evasion flux rate from soil (1/sec) not used 1.000E-10 --- REVSN C14 Fraction of grain in beef cattle feed not used 8.000E-01 --- AVFG4 C14 Fraction of grain in milk cow feed not used 2.000E-01 --- AVFG5 C14 DCF correction factor for gaseous forms of C14 not used 8.894E+01 --- CO2F
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:06 Page 6 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Ag108m-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 --- STOR_T(1)
STOR Leafy vegetables 1.000E+00 1.000E+00 --- STOR_T(2)
STOR Milk 1.000E+00 1.000E+00 --- STOR_T(3)
STOR Meat and poultry 2.000E+01 2.000E+01 --- STOR_T(4)
STOR Fish 7.000E+00 7.000E+00 --- STOR_T(5)
STOR Crustacea and mollusks 7.000E+00 7.000E+00 --- STOR_T(6)
STOR Well water 1.000E+00 1.000E+00 --- STOR_T(7)
STOR Surface water 1.000E+00 1.000E+00 --- STOR_T(8)
STOR Livestock fodder 4.500E+01 4.500E+01 --- STOR_T(9)
R021 Thickness of building foundation (m) not used 1.500E-01 --- FLOOR1 R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 --- DENSFL R021 Total porosity of the cover material not used 4.000E-01 --- TPCV R021 Total porosity of the building foundation not used 1.000E-01 --- TPFL R021 Volumetric water content of the cover material not used 5.000E-02 --- PH2OCV R021 Volumetric water content of the foundation not used 3.000E-02 --- PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.000E-06 --- DIFCV R021 in foundation material not used 3.000E-07 --- DIFFL R021 in contaminated zone soil not used 2.000E-06 --- DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.000E+00 --- HMIX R021 Average building air exchange rate (1/hr) not used 5.000E-01 --- REXG R021 Height of the building (room) (m) not used 2.500E+00 --- HRM R021 Building interior area factor not used 0.000E+00 --- FAI R021 Building depth below ground surface (m) not used -1.000E+00 --- DMFL R021 Emanating power of Rn-222 gas not used 2.500E-01 --- EMANA(1)
R021 Emanating power of Rn-220 gas not used 1.500E-01 --- EMANA(2)
TITL Number of graphical time points 32 --- --- NPTS TITL Maximum number of integration points for dose 17 --- --- LYMAX TITL Maximum number of integration points for risk 1 --- --- KYMAX Summary of Pathway Selections Pathway User Selection 1 -- external gamma active 2 -- inhalation (w/o radon) active 3 -- plant ingestion active 4 -- meat ingestion active 5 -- milk ingestion active 6 -- aquatic foods active 7 -- drinking water active 8 -- soil ingestion active 9 -- radon suppressed Find peak pathway doses suppressed
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:06 Page 7 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Ag108m-concrete-DCGL.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area: 5020.00 square meters Ag-108m 1.000E+00 Thickness: 3.80 meters Cover Depth: 0.00 meters 0
Total Dose TDOSE(t), mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years): 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 TDOSE(t): 3.379E+00 3.361E+00 3.324E+00 3.199E+00 2.868E+00 1.956E+00 6.554E-01 1.427E-02 M(t): 1.352E-01 1.344E-01 1.330E-01 1.280E-01 1.147E-01 7.824E-02 2.622E-02 5.710E-04 0Maximum TDOSE(t): 3.379E+00 mrem/yr at t = 0.000E+00 years
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:06 Page 8 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Ag108m-concrete-DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years 0 Water Independent Pathways (Inhalation excludes radon) 0 Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Ag-108m 3.369E+00 0.9970 4.177E-06 0.0000 0.000E+00 0.0000 1.710E-05 0.0000 4.954E-04 0.0001 8.499E-03 0.0025 1.076E-04 0.0000 Total 3.369E+00 0.9970 4.177E-06 0.0000 0.000E+00 0.0000 1.710E-05 0.0000 4.954E-04 0.0001 8.499E-03 0.0025 1.076E-04 0.0000 0
Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years 0 Water Dependent Pathways 0 Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Ag-108m 5.303E-04 0.0002 5.705E-06 0.0000 0.000E+00 0.0000 9.444E-05 0.0000 1.537E-05 0.0000 4.916E-04 0.0001 3.379E+00 1.0000 Total 5.303E-04 0.0002 5.705E-06 0.0000 0.000E+00 0.0000 9.444E-05 0.0000 1.537E-05 0.0000 4.916E-04 0.0001 3.379E+00 1.0000 0*Sum of all water independent and dependent pathways.
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:16 Page 1 Summary : YR submerged concrete- Sensitivity analysis, Am-241-DCGL File : Am-241-concrete_DCGL.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary ... 2 Site-Specific Parameter Summary .......................... 3 Summary of Pathway Selections ............................ 7 Contaminated Zone and Total Dose Summary ................. 8 Total Dose Components Time = 0.000E+00 .................................... 9 Time = 1.000E+00 .................................... 10 Time = 3.000E+00 .................................... 11 Time = 1.000E+01 .................................... 12 Time = 3.000E+01 .................................... 13 Time = 1.000E+02 .................................... 14 Time = 3.000E+02 .................................... 15 Time = 1.000E+03 .................................... 16 Dose/Source Ratios Summed Over All Pathways .............. 17 Single Radionuclide Soil Guidelines ...................... 17 Dose Per Nuclide Summed Over All Pathways ................ 18 Soil Concentration Per Nuclide ........................... 18
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:16 Page 2 Summary : YR submerged concrete- Sensitivity analysis, Am-241-DCGL File : Am-241-concrete_DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary File: YR Concrete 0 Current Parameter Menu Parameter Value Default Name B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 Am-241 4.440E-01 4.440E-01 DCF2( 1)
B-1 Np-237+D 5.400E-01 5.400E-01 DCF2( 2)
B-1 Th-229+D 2.160E+00 2.160E+00 DCF2( 3)
B-1 U-233 1.350E-01 1.350E-01 DCF2( 4)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Am-241 3.640E-03 3.640E-03 DCF3( 1)
D-1 Np-237+D 4.440E-03 4.440E-03 DCF3( 2)
D-1 Th-229+D 4.030E-03 4.030E-03 DCF3( 3)
D-1 U-233 2.890E-04 2.890E-04 DCF3( 4)
D-34 Food transfer factors:
D-34 Am-241 , plant/soil concentration ratio, dimensionless 7.860E-04 1.000E-03 RTF( 1,1)
D-34 Am-241 , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 5.000E-05 5.000E-05 RTF( 1,2)
D-34 Am-241 , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 2.000E-06 2.000E-06 RTF( 1,3)
D-34 D-34 Np-237+D , plant/soil concentration ratio, dimensionless 3.470E-04 2.000E-02 RTF( 2,1)
D-34 Np-237+D , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.000E-03 1.000E-03 RTF( 2,2)
D-34 Np-237+D , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.000E-05 5.000E-06 RTF( 2,3)
D-34 D-34 Th-229+D , plant/soil concentration ratio, dimensionless 8.240E-05 1.000E-03 RTF( 3,1)
D-34 Th-229+D , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.000E-04 1.000E-04 RTF( 3,2)
D-34 Th-229+D , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 5.000E-06 5.000E-06 RTF( 3,3)
D-34 D-34 U-233 , plant/soil concentration ratio, dimensionless 5.710E-03 2.500E-03 RTF( 4,1)
D-34 U-233 , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 8.000E-04 3.400E-04 RTF( 4,2)
D-34 U-233 , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 4.000E-04 6.000E-04 RTF( 4,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Am-241 , fish 6.290E+01 3.000E+01 BIOFAC( 1,1)
D-5 Am-241 , crustacea and mollusks 1.000E+03 1.000E+03 BIOFAC( 1,2)
D-5 D-5 Np-237+D , fish 3.000E+01 3.000E+01 BIOFAC( 2,1)
D-5 Np-237+D , crustacea and mollusks 4.000E+02 4.000E+02 BIOFAC( 2,2)
D-5 D-5 Th-229+D , fish 9.900E+01 1.000E+02 BIOFAC( 3,1)
D-5 Th-229+D , crustacea and mollusks 5.000E+02 5.000E+02 BIOFAC( 3,2)
D-5 D-5 U-233 , fish 1.000E+01 1.000E+01 BIOFAC( 4,1)
D-5 U-233 , crustacea and mollusks 6.000E+01 6.000E+01 BIOFAC( 4,2)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:16 Page 3 Summary : YR submerged concrete- Sensitivity analysis, Am-241-DCGL File : Am-241-concrete_DCGL.RAD Site-Specific Parameter Summary 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R011 Area of contaminated zone (m**2) 5.020E+03 1.000E+04 --- AREA R011 Thickness of contaminated zone (m) 3.800E+00 2.000E+00 --- THICK0 R011 Length parallel to aquifer flow (m) 8.000E+01 1.000E+02 --- LCZPAQ R011 Basic radiation dose limit (mrem/yr) 2.500E+01 2.500E+01 --- BRDL R011 Time since placement of material (yr) 0.000E+00 0.000E+00 --- TI R011 Times for calculations (yr) 1.000E+00 1.000E+00 --- T( 2)
R011 Times for calculations (yr) 3.000E+00 3.000E+00 --- T( 3)
R011 Times for calculations (yr) 1.000E+01 1.000E+01 --- T( 4)
R011 Times for calculations (yr) 3.000E+01 3.000E+01 --- T( 5)
R011 Times for calculations (yr) 1.000E+02 1.000E+02 --- T( 6)
R011 Times for calculations (yr) 3.000E+02 3.000E+02 --- T( 7)
R011 Times for calculations (yr) 1.000E+03 1.000E+03 --- T( 8)
R011 Times for calculations (yr) not used 0.000E+00 --- T( 9)
R011 Times for calculations (yr) not used 0.000E+00 --- T(10)
R012 Initial principal radionuclide (pCi/g): Am-241 1.000E+00 0.000E+00 --- S1( 1)
R012 Concentration in groundwater (pCi/L): Am-241 not used 0.000E+00 --- W1( 1)
R013 Cover depth (m) 0.000E+00 0.000E+00 --- COVER0 R013 Density of cover material (g/cm**3) not used 1.500E+00 --- DENSCV R013 Cover depth erosion rate (m/yr) not used 1.000E-03 --- VCV R013 Density of contaminated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSCZ R013 Contaminated zone erosion rate (m/yr) 8.500E-04 1.000E-03 --- VCZ R013 Contaminated zone total porosity 3.000E-01 4.000E-01 --- TPCZ R013 Contaminated zone field capacity 7.000E-02 2.000E-01 --- FCCZ R013 Contaminated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+01 --- HCCZ R013 Contaminated zone b parameter 9.750E-01 5.300E+00 --- BCZ R013 Average annual wind speed (m/sec) 2.030E+00 2.000E+00 --- WIND R013 Humidity in air (g/m**3) not used 8.000E+00 --- HUMID R013 Evapotranspiration coefficient 6.250E-01 5.000E-01 --- EVAPTR R013 Precipitation (m/yr) 1.200E+00 1.000E+00 --- PRECIP R013 Irrigation (m/yr) 4.350E-01 2.000E-01 --- RI R013 Irrigation mode overhead overhead --- IDITCH R013 Runoff coefficient 6.000E-01 2.000E-01 --- RUNOFF R013 Watershed area for nearby stream or pond (m**2) 7.770E+05 1.000E+06 --- WAREA R013 Accuracy for water/soil computations 1.000E-03 1.000E-03 --- EPS R014 Density of saturated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSAQ R014 Saturated zone total porosity 2.800E-01 4.000E-01 --- TPSZ R014 Saturated zone effective porosity 2.100E-01 2.000E-01 --- EPSZ R014 Saturated zone field capacity 7.000E-02 2.000E-01 --- FCSZ R014 Saturated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+02 --- HCSZ R014 Saturated zone hydraulic gradient 1.000E-01 2.000E-02 --- HGWT R014 Saturated zone b parameter 9.750E-01 5.300E+00 --- BSZ R014 Water table drop rate (m/yr) 1.000E-03 1.000E-03 --- VWT R014 Well pump intake depth (m below water table) 1.000E+01 1.000E+01 --- DWIBWT R014 Model: Nondispersion (ND) or Mass-Balance (MB) MB ND --- MODEL R014 Well pumping rate (m**3/yr) 2.500E+02 2.500E+02 --- UW R015 Number of unsaturated zone strata 0 1 --- NS
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:16 Page 4 Summary : YR submerged concrete- Sensitivity analysis, Am-241-DCGL File : Am-241-concrete_DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R016 Distribution coefficients for Am-241 R016 Contaminated zone (cm**3/g) 4.470E+02 2.000E+01 --- DCNUCC( 1)
R016 Saturated zone (cm**3/g) 0.000E+00 2.000E+01 --- DCNUCS( 1)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 1.312E-04 ALEACH( 1)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 1)
R016 Distribution coefficients for daughter Np-237 R016 Contaminated zone (cm**3/g) 7.070E+02 -1.000E+00 --- DCNUCC( 2)
R016 Saturated zone (cm**3/g) 0.000E+00 -1.000E+00 --- DCNUCS( 2)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 8.293E-05 ALEACH( 2)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 2)
R016 Distribution coefficients for daughter Th-229 R016 Contaminated zone (cm**3/g) 1.580E+03 6.000E+04 --- DCNUCC( 3)
R016 Saturated zone (cm**3/g) 0.000E+00 6.000E+04 --- DCNUCS( 3)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 3.711E-05 ALEACH( 3)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 3)
R016 Distribution coefficients for daughter U-233 R016 Contaminated zone (cm**3/g) 1.470E+02 5.000E+01 --- DCNUCC( 4)
R016 Saturated zone (cm**3/g) 0.000E+00 5.000E+01 --- DCNUCS( 4)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 3.987E-04 ALEACH( 4)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 4)
R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 --- INHALR R017 Mass loading for inhalation (g/m**3) 2.330E-05 1.000E-04 --- MLINH R017 Exposure duration 3.000E+01 3.000E+01 --- ED R017 Shielding factor, inhalation 5.500E-01 4.000E-01 --- SHF3 R017 Shielding factor, external gamma 2.725E-01 7.000E-01 --- SHF1 R017 Fraction of time spent indoors 6.571E-01 5.000E-01 --- FIND R017 Fraction of time spent outdoors (on site) 1.181E-01 2.500E-01 --- FOTD R017 Shape factor flag, external gamma 1.000E+00 1.000E+00 >0 shows circular AREA. FS R017 Radii of shape factor array (used if FS = -1):
R017 Outer annular radius (m), ring 1: not used 5.000E+01 --- RAD_SHAPE( 1)
R017 Outer annular radius (m), ring 2: not used 7.071E+01 --- RAD_SHAPE( 2)
R017 Outer annular radius (m), ring 3: not used 0.000E+00 --- RAD_SHAPE( 3)
R017 Outer annular radius (m), ring 4: not used 0.000E+00 --- RAD_SHAPE( 4)
R017 Outer annular radius (m), ring 5: not used 0.000E+00 --- RAD_SHAPE( 5)
R017 Outer annular radius (m), ring 6: not used 0.000E+00 --- RAD_SHAPE( 6)
R017 Outer annular radius (m), ring 7: not used 0.000E+00 --- RAD_SHAPE( 7)
R017 Outer annular radius (m), ring 8: not used 0.000E+00 --- RAD_SHAPE( 8)
R017 Outer annular radius (m), ring 9: not used 0.000E+00 --- RAD_SHAPE( 9)
R017 Outer annular radius (m), ring 10: not used 0.000E+00 --- RAD_SHAPE(10)
R017 Outer annular radius (m), ring 11: not used 0.000E+00 --- RAD_SHAPE(11)
R017 Outer annular radius (m), ring 12: not used 0.000E+00 --- RAD_SHAPE(12)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:16 Page 5 Summary : YR submerged concrete- Sensitivity analysis, Am-241-DCGL File : Am-241-concrete_DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R017 Fractions of annular areas within AREA:
R017 Ring 1 not used 1.000E+00 --- FRACA( 1)
R017 Ring 2 not used 2.732E-01 --- FRACA( 2)
R017 Ring 3 not used 0.000E+00 --- FRACA( 3)
R017 Ring 4 not used 0.000E+00 --- FRACA( 4)
R017 Ring 5 not used 0.000E+00 --- FRACA( 5)
R017 Ring 6 not used 0.000E+00 --- FRACA( 6)
R017 Ring 7 not used 0.000E+00 --- FRACA( 7)
R017 Ring 8 not used 0.000E+00 --- FRACA( 8)
R017 Ring 9 not used 0.000E+00 --- FRACA( 9)
R017 Ring 10 not used 0.000E+00 --- FRACA(10)
R017 Ring 11 not used 0.000E+00 --- FRACA(11)
R017 Ring 12 not used 0.000E+00 --- FRACA(12)
R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 --- DIET(1)
R018 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 --- DIET(2)
R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 --- DIET(3)
R018 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 --- DIET(4)
R018 Fish consumption (kg/yr) 2.060E+01 5.400E+00 --- DIET(5)
R018 Other seafood consumption (kg/yr) 9.000E-01 9.000E-01 --- DIET(6)
R018 Soil ingestion rate (g/yr) 1.826E+01 3.650E+01 --- SOIL R018 Drinking water intake (L/yr) 4.785E+02 5.100E+02 --- DWI R018 Contamination fraction of drinking water 1.000E+00 1.000E+00 --- FDW R018 Contamination fraction of household water not used 1.000E+00 --- FHHW R018 Contamination fraction of livestock water 1.000E+00 1.000E+00 --- FLW R018 Contamination fraction of irrigation water 1.000E+00 1.000E+00 --- FIRW R018 Contamination fraction of aquatic food 1.000E+00 5.000E-01 --- FR9 R018 Contamination fraction of plant food 1.000E+00 -1 --- FPLANT R018 Contamination fraction of meat 1.000E+00 -1 --- FMEAT R018 Contamination fraction of milk 1.000E+00 -1 --- FMILK R019 Livestock fodder intake for meat (kg/day) 2.710E+01 6.800E+01 --- LFI5 R019 Livestock fodder intake for milk (kg/day) 6.320E+01 5.500E+01 --- LFI6 R019 Livestock water intake for meat (L/day) 5.060E+01 5.000E+01 --- LWI5 R019 Livestock water intake for milk (L/day) 6.000E+01 1.600E+02 --- LWI6 R019 Livestock soil intake (kg/day) 5.000E-01 5.000E-01 --- LSI R019 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.000E-04 --- MLFD R019 Depth of soil mixing layer (m) 2.300E-01 1.500E-01 --- DM R019 Depth of roots (m) 2.050E+00 9.000E-01 --- DROOT R019 Drinking water fraction from ground water 1.000E+00 1.000E+00 --- FGWDW R019 Household water fraction from ground water not used 1.000E+00 --- FGWHH R019 Livestock water fraction from ground water 1.000E+00 1.000E+00 --- FGWLW R019 Irrigation fraction from ground water 1.000E+00 1.000E+00 --- FGWIR R19B Wet weight crop yield for Non-Leafy (kg/m**2) 1.270E+00 7.000E-01 --- YV(1)
R19B Wet weight crop yield for Leafy (kg/m**2) 2.889E+00 1.500E+00 --- YV(2)
R19B Wet weight crop yield for Fodder (kg/m**2) 1.887E+00 1.100E+00 --- YV(3)
R19B Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 --- TE(1)
R19B Growing Season for Leafy (years) 1.230E-01 2.500E-01 --- TE(2)
R19B Growing Season for Fodder (years) 8.200E-02 8.000E-02 --- TE(3)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:16 Page 6 Summary : YR submerged concrete- Sensitivity analysis, Am-241-DCGL File : Am-241-concrete_DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R19B Translocation Factor for Non-Leafy 1.000E-01 1.000E-01 --- TIV(1)
R19B Translocation Factor for Leafy 1.000E+00 1.000E+00 --- TIV(2)
R19B Translocation Factor for Fodder 1.000E+00 1.000E+00 --- TIV(3)
R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RDRY(1)
R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 --- RDRY(2)
R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RDRY(3)
R19B Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RWET(1)
R19B Wet Foliar Interception Fraction for Leafy 7.000E-01 2.500E-01 --- RWET(2)
R19B Wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RWET(3)
R19B Weathering Removal Constant for Vegetation 2.150E+01 2.000E+01 --- WLAM C14 C-12 concentration in water (g/cm**3) not used 2.000E-05 --- C12WTR C14 C-12 concentration in contaminated soil (g/g) not used 3.000E-02 --- C12CZ C14 Fraction of vegetation carbon from soil not used 2.000E-02 --- CSOIL C14 Fraction of vegetation carbon from air not used 9.800E-01 --- CAIR C14 C-14 evasion layer thickness in soil (m) not used 3.000E-01 --- DMC C14 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 --- EVSN C14 C-12 evasion flux rate from soil (1/sec) not used 1.000E-10 --- REVSN C14 Fraction of grain in beef cattle feed not used 8.000E-01 --- AVFG4 C14 Fraction of grain in milk cow feed not used 2.000E-01 --- AVFG5 C14 DCF correction factor for gaseous forms of C14 not used 8.894E+01 --- CO2F STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 --- STOR_T(1)
STOR Leafy vegetables 1.000E+00 1.000E+00 --- STOR_T(2)
STOR Milk 1.000E+00 1.000E+00 --- STOR_T(3)
STOR Meat and poultry 2.000E+01 2.000E+01 --- STOR_T(4)
STOR Fish 7.000E+00 7.000E+00 --- STOR_T(5)
STOR Crustacea and mollusks 7.000E+00 7.000E+00 --- STOR_T(6)
STOR Well water 1.000E+00 1.000E+00 --- STOR_T(7)
STOR Surface water 1.000E+00 1.000E+00 --- STOR_T(8)
STOR Livestock fodder 4.500E+01 4.500E+01 --- STOR_T(9)
R021 Thickness of building foundation (m) not used 1.500E-01 --- FLOOR1 R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 --- DENSFL R021 Total porosity of the cover material not used 4.000E-01 --- TPCV R021 Total porosity of the building foundation not used 1.000E-01 --- TPFL R021 Volumetric water content of the cover material not used 5.000E-02 --- PH2OCV R021 Volumetric water content of the foundation not used 3.000E-02 --- PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.000E-06 --- DIFCV R021 in foundation material not used 3.000E-07 --- DIFFL R021 in contaminated zone soil not used 2.000E-06 --- DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.000E+00 --- HMIX R021 Average building air exchange rate (1/hr) not used 5.000E-01 --- REXG R021 Height of the building (room) (m) not used 2.500E+00 --- HRM R021 Building interior area factor not used 0.000E+00 --- FAI R021 Building depth below ground surface (m) not used -1.000E+00 --- DMFL R021 Emanating power of Rn-222 gas not used 2.500E-01 --- EMANA(1)
R021 Emanating power of Rn-220 gas not used 1.500E-01 --- EMANA(2)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:16 Page 7 Summary : YR submerged concrete- Sensitivity analysis, Am-241-DCGL File : Am-241-concrete_DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name TITL Number of graphical time points 32 --- --- NPTS TITL Maximum number of integration points for dose 17 --- --- LYMAX TITL Maximum number of integration points for risk 1 --- --- KYMAX Summary of Pathway Selections Pathway User Selection 1 -- external gamma active 2 -- inhalation (w/o radon) active 3 -- plant ingestion active 4 -- meat ingestion active 5 -- milk ingestion active 6 -- aquatic foods active 7 -- drinking water active 8 -- soil ingestion active 9 -- radon suppressed Find peak pathway doses suppressed
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:16 Page 8 Summary : YR submerged concrete- Sensitivity analysis, Am-241-DCGL File : Am-241-concrete_DCGL.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area: 5020.00 square meters Am-241 1.000E+00 Thickness: 3.80 meters Cover Depth: 0.00 meters 0
Total Dose TDOSE(t), mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years): 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 TDOSE(t): 5.496E+00 5.760E+00 5.738E+00 5.661E+00 5.445E+00 4.753E+00 3.218E+00 8.092E-01 M(t): 2.199E-01 2.304E-01 2.295E-01 2.264E-01 2.178E-01 1.901E-01 1.287E-01 3.237E-02 0Maximum TDOSE(t): 5.772E+00 mrem/yr at t = 0.1183 +/- 0.0002 years 0
Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.183E-01 years 0 Water Independent Pathways (Inhalation excludes radon) 0 Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Nuclide Am-241 1.240E-02 0.0021 6.564E-03 0.0011 0.000E+00 0.0000 3.831E-01 0.0664 6.174E-03 0.0011 9.329E-04 0.0002 5.147E-02 0.0089 Total 1.240E-02 0.0021 6.564E-03 0.0011 0.000E+00 0.0000 3.831E-01 0.0664 6.174E-03 0.0011 9.329E-04 0.0002 5.147E-02 0.0089 0
Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.183E-01 years 0 Water Dependent Pathways 0 Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Nuclide Am-241 3.893E+00 0.6743 1.156E-01 0.0200 0.000E+00 0.0000 1.299E+00 0.2251 3.350E-03 0.0006 9.423E-04 0.0002 5.772E+00 1.0000 Total 3.893E+00 0.6743 1.156E-01 0.0200 0.000E+00 0.0000 1.299E+00 0.2251 3.350E-03 0.0006 9.423E-04 0.0002 5.772E+00 1.0000 0*Sum of all water independent and dependent pathways.
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:26 Page 1 Summary : YR submerged concrete- DCGL, C-14 File: C-14-concrete_DCGL.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary ... 2 Site-Specific Parameter Summary .......................... 3 Summary of Pathway Selections ............................ 6 Contaminated Zone and Total Dose Summary ................. 7 Total Dose Components Time = 0.000E+00 .................................... 8 Time = 1.000E+00 .................................... 9 Time = 3.000E+00 .................................... 10 Time = 1.000E+01 .................................... 11 Time = 3.000E+01 .................................... 12 Time = 1.000E+02 .................................... 13 Time = 3.000E+02 .................................... 14 Time = 1.000E+03 .................................... 15 Dose/Source Ratios Summed Over All Pathways .............. 16 Single Radionuclide Soil Guidelines ...................... 16 Dose Per Nuclide Summed Over All Pathways ................ 17 Soil Concentration Per Nuclide ........................... 17
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:26 Page 2 Summary : YR submerged concrete- DCGL, C-14 File: C-14-concrete_DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary File: YR Concrete 0 Current Parameter Menu Parameter Value Default Name B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 C-14 2.090E-06 2.090E-06 DCF2( 1)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 C-14 2.090E-06 2.090E-06 DCF3( 1)
D-34 Food transfer factors:
D-34 C-14 , plant/soil concentration ratio, dimensionless 2.120E-02 5.500E+00 RTF( 1,1)
D-34 C-14 , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 3.100E-02 3.100E-02 RTF( 1,2)
D-34 C-14 , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.200E-02 1.200E-02 RTF( 1,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 C-14 , fish 1.030E+05 5.000E+04 BIOFAC( 1,1)
D-5 C-14 , crustacea and mollusks 9.100E+03 9.100E+03 BIOFAC( 1,2)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:26 Page 3 Summary : YR submerged concrete- DCGL, C-14 File: C-14-concrete_DCGL.RAD Site-Specific Parameter Summary 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R011 Area of contaminated zone (m**2) 5.020E+03 1.000E+04 --- AREA R011 Thickness of contaminated zone (m) 3.800E+00 2.000E+00 --- THICK0 R011 Length parallel to aquifer flow (m) 8.000E+01 1.000E+02 --- LCZPAQ R011 Basic radiation dose limit (mrem/yr) 2.500E+01 2.500E+01 --- BRDL R011 Time since placement of material (yr) 0.000E+00 0.000E+00 --- TI R011 Times for calculations (yr) 1.000E+00 1.000E+00 --- T( 2)
R011 Times for calculations (yr) 3.000E+00 3.000E+00 --- T( 3)
R011 Times for calculations (yr) 1.000E+01 1.000E+01 --- T( 4)
R011 Times for calculations (yr) 3.000E+01 3.000E+01 --- T( 5)
R011 Times for calculations (yr) 1.000E+02 1.000E+02 --- T( 6)
R011 Times for calculations (yr) 3.000E+02 3.000E+02 --- T( 7)
R011 Times for calculations (yr) 1.000E+03 1.000E+03 --- T( 8)
R011 Times for calculations (yr) not used 0.000E+00 --- T( 9)
R011 Times for calculations (yr) not used 0.000E+00 --- T(10)
R012 Initial principal radionuclide (pCi/g): C-14 1.000E+00 0.000E+00 --- S1( 1)
R012 Concentration in groundwater (pCi/L): C-14 not used 0.000E+00 --- W1( 1)
R013 Cover depth (m) 0.000E+00 0.000E+00 --- COVER0 R013 Density of cover material (g/cm**3) not used 1.500E+00 --- DENSCV R013 Cover depth erosion rate (m/yr) not used 1.000E-03 --- VCV R013 Density of contaminated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSCZ R013 Contaminated zone erosion rate (m/yr) 8.500E-04 1.000E-03 --- VCZ R013 Contaminated zone total porosity 3.000E-01 4.000E-01 --- TPCZ R013 Contaminated zone field capacity 7.000E-02 2.000E-01 --- FCCZ R013 Contaminated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+01 --- HCCZ R013 Contaminated zone b parameter 9.750E-01 5.300E+00 --- BCZ R013 Average annual wind speed (m/sec) 2.030E+00 2.000E+00 --- WIND R013 Humidity in air (g/m**3) not used 8.000E+00 --- HUMID R013 Evapotranspiration coefficient 6.250E-01 5.000E-01 --- EVAPTR R013 Precipitation (m/yr) 1.200E+00 1.000E+00 --- PRECIP R013 Irrigation (m/yr) 4.350E-01 2.000E-01 --- RI R013 Irrigation mode overhead overhead --- IDITCH R013 Runoff coefficient 6.000E-01 2.000E-01 --- RUNOFF R013 Watershed area for nearby stream or pond (m**2) 7.770E+05 1.000E+06 --- WAREA R013 Accuracy for water/soil computations 1.000E-03 1.000E-03 --- EPS R014 Density of saturated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSAQ R014 Saturated zone total porosity 2.800E-01 4.000E-01 --- TPSZ R014 Saturated zone effective porosity 2.100E-01 2.000E-01 --- EPSZ R014 Saturated zone field capacity 7.000E-02 2.000E-01 --- FCSZ R014 Saturated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+02 --- HCSZ R014 Saturated zone hydraulic gradient 1.000E-01 2.000E-02 --- HGWT R014 Saturated zone b parameter 9.750E-01 5.300E+00 --- BSZ R014 Water table drop rate (m/yr) 1.000E-03 1.000E-03 --- VWT R014 Well pump intake depth (m below water table) 1.000E+01 1.000E+01 --- DWIBWT R014 Model: Nondispersion (ND) or Mass-Balance (MB) MB ND --- MODEL R014 Well pumping rate (m**3/yr) 2.500E+02 2.500E+02 --- UW R015 Number of unsaturated zone strata 0 1 --- NS
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:26 Page 4 Summary : YR submerged concrete- DCGL, C-14 File: C-14-concrete_DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R016 Distribution coefficients for C-14 R016 Contaminated zone (cm**3/g) 7.070E+01 0.000E+00 --- DCNUCC( 1)
R016 Saturated zone (cm**3/g) 0.000E+00 0.000E+00 --- DCNUCS( 1)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 8.288E-04 ALEACH( 1)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 1)
R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 --- INHALR R017 Mass loading for inhalation (g/m**3) 2.330E-05 1.000E-04 --- MLINH R017 Exposure duration 3.000E+01 3.000E+01 --- ED R017 Shielding factor, inhalation 5.500E-01 4.000E-01 --- SHF3 R017 Shielding factor, external gamma 2.725E-01 7.000E-01 --- SHF1 R017 Fraction of time spent indoors 6.571E-01 5.000E-01 --- FIND R017 Fraction of time spent outdoors (on site) 1.181E-01 2.500E-01 --- FOTD R017 Shape factor flag, external gamma 1.000E+00 1.000E+00 >0 shows circular AREA. FS R017 Radii of shape factor array (used if FS = -1):
R017 Outer annular radius (m), ring 1: not used 5.000E+01 --- RAD_SHAPE( 1)
R017 Outer annular radius (m), ring 2: not used 7.071E+01 --- RAD_SHAPE( 2)
R017 Outer annular radius (m), ring 3: not used 0.000E+00 --- RAD_SHAPE( 3)
R017 Outer annular radius (m), ring 4: not used 0.000E+00 --- RAD_SHAPE( 4)
R017 Outer annular radius (m), ring 5: not used 0.000E+00 --- RAD_SHAPE( 5)
R017 Outer annular radius (m), ring 6: not used 0.000E+00 --- RAD_SHAPE( 6)
R017 Outer annular radius (m), ring 7: not used 0.000E+00 --- RAD_SHAPE( 7)
R017 Outer annular radius (m), ring 8: not used 0.000E+00 --- RAD_SHAPE( 8)
R017 Outer annular radius (m), ring 9: not used 0.000E+00 --- RAD_SHAPE( 9)
R017 Outer annular radius (m), ring 10: not used 0.000E+00 --- RAD_SHAPE(10)
R017 Outer annular radius (m), ring 11: not used 0.000E+00 --- RAD_SHAPE(11)
R017 Outer annular radius (m), ring 12: not used 0.000E+00 --- RAD_SHAPE(12)
R017 Fractions of annular areas within AREA:
R017 Ring 1 not used 1.000E+00 --- FRACA( 1)
R017 Ring 2 not used 2.732E-01 --- FRACA( 2)
R017 Ring 3 not used 0.000E+00 --- FRACA( 3)
R017 Ring 4 not used 0.000E+00 --- FRACA( 4)
R017 Ring 5 not used 0.000E+00 --- FRACA( 5)
R017 Ring 6 not used 0.000E+00 --- FRACA( 6)
R017 Ring 7 not used 0.000E+00 --- FRACA( 7)
R017 Ring 8 not used 0.000E+00 --- FRACA( 8)
R017 Ring 9 not used 0.000E+00 --- FRACA( 9)
R017 Ring 10 not used 0.000E+00 --- FRACA(10)
R017 Ring 11 not used 0.000E+00 --- FRACA(11)
R017 Ring 12 not used 0.000E+00 --- FRACA(12)
R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 --- DIET(1)
R018 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 --- DIET(2)
R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 --- DIET(3)
R018 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 --- DIET(4)
R018 Fish consumption (kg/yr) 2.060E+01 5.400E+00 --- DIET(5)
R018 Other seafood consumption (kg/yr) 9.000E-01 9.000E-01 --- DIET(6)
R018 Soil ingestion rate (g/yr) 1.826E+01 3.650E+01 --- SOIL R018 Drinking water intake (L/yr) 4.785E+02 5.100E+02 --- DWI R018 Contamination fraction of drinking water 1.000E+00 1.000E+00 --- FDW
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:26 Page 5 Summary : YR submerged concrete- DCGL, C-14 File: C-14-concrete_DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R018 Contamination fraction of household water not used 1.000E+00 --- FHHW R018 Contamination fraction of livestock water 1.000E+00 1.000E+00 --- FLW R018 Contamination fraction of irrigation water 1.000E+00 1.000E+00 --- FIRW R018 Contamination fraction of aquatic food 1.000E+00 5.000E-01 --- FR9 R018 Contamination fraction of plant food 1.000E+00 -1 --- FPLANT R018 Contamination fraction of meat 1.000E+00 -1 --- FMEAT R018 Contamination fraction of milk 1.000E+00 -1 --- FMILK R019 Livestock fodder intake for meat (kg/day) 2.710E+01 6.800E+01 --- LFI5 R019 Livestock fodder intake for milk (kg/day) 6.320E+01 5.500E+01 --- LFI6 R019 Livestock water intake for meat (L/day) 5.060E+01 5.000E+01 --- LWI5 R019 Livestock water intake for milk (L/day) 6.000E+01 1.600E+02 --- LWI6 R019 Livestock soil intake (kg/day) 5.000E-01 5.000E-01 --- LSI R019 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.000E-04 --- MLFD R019 Depth of soil mixing layer (m) 2.300E-01 1.500E-01 --- DM R019 Depth of roots (m) 2.050E+00 9.000E-01 --- DROOT R019 Drinking water fraction from ground water 1.000E+00 1.000E+00 --- FGWDW R019 Household water fraction from ground water not used 1.000E+00 --- FGWHH R019 Livestock water fraction from ground water 1.000E+00 1.000E+00 --- FGWLW R019 Irrigation fraction from ground water 1.000E+00 1.000E+00 --- FGWIR R19B Wet weight crop yield for Non-Leafy (kg/m**2) 1.750E+00 7.000E-01 --- YV(1)
R19B Wet weight crop yield for Leafy (kg/m**2) 2.889E+00 1.500E+00 --- YV(2)
R19B Wet weight crop yield for Fodder (kg/m**2) 1.887E+00 1.100E+00 --- YV(3)
R19B Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 --- TE(1)
R19B Growing Season for Leafy (years) 1.230E-01 2.500E-01 --- TE(2)
R19B Growing Season for Fodder (years) 8.200E-02 8.000E-02 --- TE(3)
R19B Translocation Factor for Non-Leafy 1.000E-01 1.000E-01 --- TIV(1)
R19B Translocation Factor for Leafy 1.000E+00 1.000E+00 --- TIV(2)
R19B Translocation Factor for Fodder 1.000E+00 1.000E+00 --- TIV(3)
R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RDRY(1)
R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 --- RDRY(2)
R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RDRY(3)
R19B Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RWET(1)
R19B Wet Foliar Interception Fraction for Leafy 5.800E-01 2.500E-01 --- RWET(2)
R19B Wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RWET(3)
R19B Weathering Removal Constant for Vegetation 3.300E+01 2.000E+01 --- WLAM C14 C-12 concentration in water (g/cm**3) 2.000E-05 2.000E-05 --- C12WTR C14 C-12 concentration in contaminated soil (g/g) 3.000E-02 3.000E-02 --- C12CZ C14 Fraction of vegetation carbon from soil 2.000E-02 2.000E-02 --- CSOIL C14 Fraction of vegetation carbon from air 9.800E-01 9.800E-01 --- CAIR C14 C-14 evasion layer thickness in soil (m) 4.270E-01 3.000E-01 --- DMC C14 C-14 evasion flux rate from soil (1/sec) 7.000E-07 7.000E-07 --- EVSN C14 C-12 evasion flux rate from soil (1/sec) 1.000E-10 1.000E-10 --- REVSN C14 Fraction of grain in beef cattle feed 2.500E-01 8.000E-01 --- AVFG4 C14 Fraction of grain in milk cow feed 1.000E-01 2.000E-01 --- AVFG5 C14 DCF correction factor for gaseous forms of C14 8.894E+01 8.894E+01 --- CO2F STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 --- STOR_T(1)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:26 Page 6 Summary : YR submerged concrete- DCGL, C-14 File: C-14-concrete_DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name STOR Leafy vegetables 1.000E+00 1.000E+00 --- STOR_T(2)
STOR Milk 1.000E+00 1.000E+00 --- STOR_T(3)
STOR Meat and poultry 2.000E+01 2.000E+01 --- STOR_T(4)
STOR Fish 7.000E+00 7.000E+00 --- STOR_T(5)
STOR Crustacea and mollusks 7.000E+00 7.000E+00 --- STOR_T(6)
STOR Well water 1.000E+00 1.000E+00 --- STOR_T(7)
STOR Surface water 1.000E+00 1.000E+00 --- STOR_T(8)
STOR Livestock fodder 4.500E+01 4.500E+01 --- STOR_T(9)
R021 Thickness of building foundation (m) not used 1.500E-01 --- FLOOR1 R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 --- DENSFL R021 Total porosity of the cover material not used 4.000E-01 --- TPCV R021 Total porosity of the building foundation not used 1.000E-01 --- TPFL R021 Volumetric water content of the cover material not used 5.000E-02 --- PH2OCV R021 Volumetric water content of the foundation not used 3.000E-02 --- PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.000E-06 --- DIFCV R021 in foundation material not used 3.000E-07 --- DIFFL R021 in contaminated zone soil not used 2.000E-06 --- DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.000E+00 --- HMIX R021 Average building air exchange rate (1/hr) not used 5.000E-01 --- REXG R021 Height of the building (room) (m) not used 2.500E+00 --- HRM R021 Building interior area factor not used 0.000E+00 --- FAI R021 Building depth below ground surface (m) not used -1.000E+00 --- DMFL R021 Emanating power of Rn-222 gas not used 2.500E-01 --- EMANA(1)
R021 Emanating power of Rn-220 gas not used 1.500E-01 --- EMANA(2)
TITL Number of graphical time points 32 --- --- NPTS TITL Maximum number of integration points for dose 17 --- --- LYMAX TITL Maximum number of integration points for risk 1 --- --- KYMAX Summary of Pathway Selections Pathway User Selection 1 -- external gamma active 2 -- inhalation (w/o radon) active 3 -- plant ingestion active 4 -- meat ingestion active 5 -- milk ingestion active 6 -- aquatic foods active 7 -- drinking water active 8 -- soil ingestion active 9 -- radon suppressed Find peak pathway doses suppressed
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:26 Page 7 Summary : YR submerged concrete- DCGL, C-14 File: C-14-concrete_DCGL.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area: 5020.00 square meters C-14 1.000E+00 Thickness: 3.80 meters Cover Depth: 0.00 meters 0
Total Dose TDOSE(t), mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years): 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 TDOSE(t): 3.305E+00 2.954E-01 2.035E-03 5.328E-11 0.000E+00 0.000E+00 0.000E+00 0.000E+00 M(t): 1.322E-01 1.182E-02 8.139E-05 2.131E-12 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0Maximum TDOSE(t): 3.305E+00 mrem/yr at t = 0.000E+00 years
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:26 Page 8 Summary : YR submerged concrete- DCGL, C-14 File: C-14-concrete_DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years 0 Water Independent Pathways (Inhalation excludes radon) 0 Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
C-14 1.418E-06 0.0000 2.266E-04 0.0001 0.000E+00 0.0000 1.702E+00 0.5150 7.321E-01 0.2215 6.943E-01 0.2101 1.091E-05 0.0000 Total 1.418E-06 0.0000 2.266E-04 0.0001 0.000E+00 0.0000 1.702E+00 0.5150 7.321E-01 0.2215 6.943E-01 0.2101 1.091E-05 0.0000 0
Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years 0 Water Dependent Pathways 0 Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
C-14 5.151E-03 0.0016 1.534E-01 0.0464 0.000E+00 0.0000 1.123E-02 0.0034 3.436E-03 0.0010 2.842E-03 0.0009 3.305E+00 1.0000 Total 5.151E-03 0.0016 1.534E-01 0.0464 0.000E+00 0.0000 1.123E-02 0.0034 3.436E-03 0.0010 2.842E-03 0.0009 3.305E+00 1.0000 0*Sum of all water independent and dependent pathways.
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/10/2004 14:35 Page 1 Summary : YR submerged concrete- DCGL, Cm-243 File: Cm-243-concrete_DCGL.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary ... 2 Site-Specific Parameter Summary .......................... 4 Summary of Pathway Selections ............................ 8 Contaminated Zone and Total Dose Summary ................. 9 Total Dose Components Time = 0.000E+00 .................................... 10 Time = 1.000E+00 .................................... 11 Time = 3.000E+00 .................................... 12 Time = 1.000E+01 .................................... 13 Time = 3.000E+01 .................................... 14 Time = 1.000E+02 .................................... 15 Time = 3.000E+02 .................................... 16 Time = 1.000E+03 .................................... 17 Dose/Source Ratios Summed Over All Pathways .............. 18 Single Radionuclide Soil Guidelines ...................... 18 Dose Per Nuclide Summed Over All Pathways ................ 19 Soil Concentration Per Nuclide ........................... 20
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/10/2004 14:35 Page 2 Summary : YR submerged concrete- DCGL, Cm-243 File: Cm-243-concrete_DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary File: YR Concrete 0 Current Parameter Menu Parameter Value Default Name B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 Ac-227+D 6.720E+00 6.720E+00 DCF2( 1)
B-1 Am-243+D 4.400E-01 4.400E-01 DCF2( 2)
B-1 Cm-243 3.070E-01 3.070E-01 DCF2( 3)
B-1 Pa-231 1.280E+00 1.280E+00 DCF2( 5)
B-1 Pu-239 4.290E-01 4.290E-01 DCF2( 6)
B-1 U-235+D 1.230E-01 1.230E-01 DCF2( 7)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Ac-227+D 1.480E-02 1.480E-02 DCF3( 1)
D-1 Am-243+D 3.630E-03 3.630E-03 DCF3( 2)
D-1 Cm-243 2.510E-03 2.510E-03 DCF3( 3)
D-1 Pa-231 1.060E-02 1.060E-02 DCF3( 5)
D-1 Pu-239 3.540E-03 3.540E-03 DCF3( 6)
D-1 U-235+D 2.670E-04 2.670E-04 DCF3( 7)
D-34 Food transfer factors:
D-34 Ac-227+D , plant/soil concentration ratio, dimensionless 1.870E-04 2.500E-03 RTF( 1,1)
D-34 Ac-227+D , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 2.000E-05 2.000E-05 RTF( 1,2)
D-34 Ac-227+D , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 2.000E-06 2.000E-05 RTF( 1,3)
D-34 D-34 Am-243+D , plant/soil concentration ratio, dimensionless 1.870E-04 1.000E-03 RTF( 2,1)
D-34 Am-243+D , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 5.000E-05 5.000E-05 RTF( 2,2)
D-34 Am-243+D , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 2.000E-06 2.000E-06 RTF( 2,3)
D-34 D-34 Cm-243 , plant/soil concentration ratio, dimensionless 2.530E-03 1.000E-03 RTF( 3,1)
D-34 Cm-243 , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 2.000E-05 2.000E-05 RTF( 3,2)
D-34 Cm-243 , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 2.000E-06 2.000E-06 RTF( 3,3)
D-34 D-34 Pa-231 , plant/soil concentration ratio, dimensionless 1.460E-03 1.000E-02 RTF( 5,1)
D-34 Pa-231 , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 5.000E-06 5.000E-03 RTF( 5,2)
D-34 Pa-231 , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 5.000E-06 5.000E-06 RTF( 5,3)
D-34 D-34 Pu-239 , plant/soil concentration ratio, dimensionless 8.240E-05 1.000E-03 RTF( 6,1)
D-34 Pu-239 , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.000E-04 1.000E-04 RTF( 6,2)
D-34 Pu-239 , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.000E-06 1.000E-06 RTF( 6,3)
D-34 D-34 U-235+D , plant/soil concentration ratio, dimensionless 5.710E-03 2.500E-03 RTF( 7,1)
D-34 U-235+D , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 8.000E-04 3.400E-04 RTF( 7,2)
D-34 U-235+D , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 4.000E-04 6.000E-04 RTF( 7,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Ac-227+D , fish 1.500E+01 1.500E+01 BIOFAC( 1,1)
D-5 Ac-227+D , crustacea and mollusks 1.000E+03 1.000E+03 BIOFAC( 1,2)
D-5 D-5 Am-243+D , fish 3.000E+01 3.000E+01 BIOFAC( 2,1)
D-5 Am-243+D , crustacea and mollusks 1.000E+03 1.000E+03 BIOFAC( 2,2)
D-5 D-5 Cm-243 , fish 3.000E+01 3.000E+01 BIOFAC( 3,1)
D-5 Cm-243 , crustacea and mollusks 1.000E+03 1.000E+03 BIOFAC( 3,2)
D-5
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/10/2004 14:35 Page 3 Summary : YR submerged concrete- DCGL, Cm-243 File: Cm-243-concrete_DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)
File: YR Concrete 0 Current Parameter Menu Parameter Value Default Name D-5 Pa-231 , fish 1.000E+01 1.000E+01 BIOFAC( 5,1)
D-5 Pa-231 , crustacea and mollusks 1.100E+02 1.100E+02 BIOFAC( 5,2)
D-5 D-5 Pu-239 , fish 3.000E+01 3.000E+01 BIOFAC( 6,1)
D-5 Pu-239 , crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC( 6,2)
D-5 D-5 U-235+D , fish 1.000E+01 1.000E+01 BIOFAC( 7,1)
D-5 U-235+D , crustacea and mollusks 6.000E+01 6.000E+01 BIOFAC( 7,2)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/10/2004 14:35 Page 4 Summary : YR submerged concrete- DCGL, Cm-243 File: Cm-243-concrete_DCGL.RAD Site-Specific Parameter Summary 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R011 Area of contaminated zone (m**2) 5.020E+03 1.000E+04 --- AREA R011 Thickness of contaminated zone (m) 3.800E+00 2.000E+00 --- THICK0 R011 Length parallel to aquifer flow (m) 8.000E+01 1.000E+02 --- LCZPAQ R011 Basic radiation dose limit (mrem/yr) 2.500E+01 2.500E+01 --- BRDL R011 Time since placement of material (yr) 0.000E+00 0.000E+00 --- TI R011 Times for calculations (yr) 1.000E+00 1.000E+00 --- T( 2)
R011 Times for calculations (yr) 3.000E+00 3.000E+00 --- T( 3)
R011 Times for calculations (yr) 1.000E+01 1.000E+01 --- T( 4)
R011 Times for calculations (yr) 3.000E+01 3.000E+01 --- T( 5)
R011 Times for calculations (yr) 1.000E+02 1.000E+02 --- T( 6)
R011 Times for calculations (yr) 3.000E+02 3.000E+02 --- T( 7)
R011 Times for calculations (yr) 1.000E+03 1.000E+03 --- T( 8)
R011 Times for calculations (yr) not used 0.000E+00 --- T( 9)
R011 Times for calculations (yr) not used 0.000E+00 --- T(10)
R012 Initial principal radionuclide (pCi/g): Cm-243 1.000E+00 0.000E+00 --- S1( 3)
R012 Concentration in groundwater (pCi/L): Cm-243 not used 0.000E+00 --- W1( 3)
R013 Cover depth (m) 0.000E+00 0.000E+00 --- COVER0 R013 Density of cover material (g/cm**3) not used 1.500E+00 --- DENSCV R013 Cover depth erosion rate (m/yr) not used 1.000E-03 --- VCV R013 Density of contaminated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSCZ R013 Contaminated zone erosion rate (m/yr) 8.500E-04 1.000E-03 --- VCZ R013 Contaminated zone total porosity 3.000E-01 4.000E-01 --- TPCZ R013 Contaminated zone field capacity 7.000E-02 2.000E-01 --- FCCZ R013 Contaminated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+01 --- HCCZ R013 Contaminated zone b parameter 9.750E-01 5.300E+00 --- BCZ R013 Average annual wind speed (m/sec) 2.030E+00 2.000E+00 --- WIND R013 Humidity in air (g/m**3) not used 8.000E+00 --- HUMID R013 Evapotranspiration coefficient 6.250E-01 5.000E-01 --- EVAPTR R013 Precipitation (m/yr) 1.200E+00 1.000E+00 --- PRECIP R013 Irrigation (m/yr) 4.350E-01 2.000E-01 --- RI R013 Irrigation mode overhead overhead --- IDITCH R013 Runoff coefficient 6.000E-01 2.000E-01 --- RUNOFF R013 Watershed area for nearby stream or pond (m**2) 7.770E+05 1.000E+06 --- WAREA R013 Accuracy for water/soil computations 1.000E-03 1.000E-03 --- EPS R014 Density of saturated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSAQ R014 Saturated zone total porosity 2.800E-01 4.000E-01 --- TPSZ R014 Saturated zone effective porosity 2.100E-01 2.000E-01 --- EPSZ R014 Saturated zone field capacity 7.000E-02 2.000E-01 --- FCSZ R014 Saturated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+02 --- HCSZ R014 Saturated zone hydraulic gradient 1.000E-01 2.000E-02 --- HGWT R014 Saturated zone b parameter 9.750E-01 5.300E+00 --- BSZ R014 Water table drop rate (m/yr) 1.000E-03 1.000E-03 --- VWT R014 Well pump intake depth (m below water table) 1.000E+01 1.000E+01 --- DWIBWT R014 Model: Nondispersion (ND) or Mass-Balance (MB) MB ND --- MODEL R014 Well pumping rate (m**3/yr) 2.500E+02 2.500E+02 --- UW R015 Number of unsaturated zone strata 0 1 --- NS
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/10/2004 14:35 Page 5 Summary : YR submerged concrete- DCGL, Cm-243 File: Cm-243-concrete_DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R016 Distribution coefficients for Cm-243 R016 Contaminated zone (cm**3/g) 4.000E+02 -1.000E+00 --- DCNUCC( 3)
R016 Saturated zone (cm**3/g) 0.000E+00 -1.000E+00 --- DCNUCS( 3)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 1.466E-04 ALEACH( 3)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 3)
R016 Distribution coefficients for daughter Ac-227 R016 Contaminated zone (cm**3/g) 1.000E+03 2.000E+01 --- DCNUCC( 1)
R016 Saturated zone (cm**3/g) 0.000E+00 2.000E+01 --- DCNUCS( 1)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 5.863E-05 ALEACH( 1)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 1)
R016 Distribution coefficients for daughter Am-243 R016 Contaminated zone (cm**3/g) 1.000E+03 2.000E+01 --- DCNUCC( 2)
R016 Saturated zone (cm**3/g) 0.000E+00 2.000E+01 --- DCNUCS( 2)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 5.863E-05 ALEACH( 2)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 2)
R016 Distribution coefficients for daughter Pa-231 R016 Contaminated zone (cm**3/g) 3.160E+02 5.000E+01 --- DCNUCC( 5)
R016 Saturated zone (cm**3/g) 0.000E+00 5.000E+01 --- DCNUCS( 5)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 1.855E-04 ALEACH( 5)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 5)
R016 Distribution coefficients for daughter Pu-239 R016 Contaminated zone (cm**3/g) 1.580E+03 2.000E+03 --- DCNUCC( 6)
R016 Saturated zone (cm**3/g) 0.000E+00 2.000E+03 --- DCNUCS( 6)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 3.711E-05 ALEACH( 6)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 6)
R016 Distribution coefficients for daughter U-235 R016 Contaminated zone (cm**3/g) 1.470E+02 5.000E+01 --- DCNUCC( 7)
R016 Saturated zone (cm**3/g) 0.000E+00 5.000E+01 --- DCNUCS( 7)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 3.987E-04 ALEACH( 7)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 7)
R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 --- INHALR R017 Mass loading for inhalation (g/m**3) 2.330E-05 1.000E-04 --- MLINH R017 Exposure duration 3.000E+01 3.000E+01 --- ED R017 Shielding factor, inhalation 5.500E-01 4.000E-01 --- SHF3 R017 Shielding factor, external gamma 3.980E-01 7.000E-01 --- SHF1 R017 Fraction of time spent indoors 6.571E-01 5.000E-01 --- FIND R017 Fraction of time spent outdoors (on site) 1.181E-01 2.500E-01 --- FOTD R017 Shape factor flag, external gamma 1.000E+00 1.000E+00 >0 shows circular AREA. FS
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/10/2004 14:35 Page 6 Summary : YR submerged concrete- DCGL, Cm-243 File: Cm-243-concrete_DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R017 Radii of shape factor array (used if FS = -1):
R017 Outer annular radius (m), ring 1: not used 5.000E+01 --- RAD_SHAPE( 1)
R017 Outer annular radius (m), ring 2: not used 7.071E+01 --- RAD_SHAPE( 2)
R017 Outer annular radius (m), ring 3: not used 0.000E+00 --- RAD_SHAPE( 3)
R017 Outer annular radius (m), ring 4: not used 0.000E+00 --- RAD_SHAPE( 4)
R017 Outer annular radius (m), ring 5: not used 0.000E+00 --- RAD_SHAPE( 5)
R017 Outer annular radius (m), ring 6: not used 0.000E+00 --- RAD_SHAPE( 6)
R017 Outer annular radius (m), ring 7: not used 0.000E+00 --- RAD_SHAPE( 7)
R017 Outer annular radius (m), ring 8: not used 0.000E+00 --- RAD_SHAPE( 8)
R017 Outer annular radius (m), ring 9: not used 0.000E+00 --- RAD_SHAPE( 9)
R017 Outer annular radius (m), ring 10: not used 0.000E+00 --- RAD_SHAPE(10)
R017 Outer annular radius (m), ring 11: not used 0.000E+00 --- RAD_SHAPE(11)
R017 Outer annular radius (m), ring 12: not used 0.000E+00 --- RAD_SHAPE(12)
R017 Fractions of annular areas within AREA:
R017 Ring 1 not used 1.000E+00 --- FRACA( 1)
R017 Ring 2 not used 2.732E-01 --- FRACA( 2)
R017 Ring 3 not used 0.000E+00 --- FRACA( 3)
R017 Ring 4 not used 0.000E+00 --- FRACA( 4)
R017 Ring 5 not used 0.000E+00 --- FRACA( 5)
R017 Ring 6 not used 0.000E+00 --- FRACA( 6)
R017 Ring 7 not used 0.000E+00 --- FRACA( 7)
R017 Ring 8 not used 0.000E+00 --- FRACA( 8)
R017 Ring 9 not used 0.000E+00 --- FRACA( 9)
R017 Ring 10 not used 0.000E+00 --- FRACA(10)
R017 Ring 11 not used 0.000E+00 --- FRACA(11)
R017 Ring 12 not used 0.000E+00 --- FRACA(12)
R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 --- DIET(1)
R018 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 --- DIET(2)
R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 --- DIET(3)
R018 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 --- DIET(4)
R018 Fish consumption (kg/yr) 2.060E+01 5.400E+00 --- DIET(5)
R018 Other seafood consumption (kg/yr) 9.000E-01 9.000E-01 --- DIET(6)
R018 Soil ingestion rate (g/yr) 1.826E+01 3.650E+01 --- SOIL R018 Drinking water intake (L/yr) 4.785E+02 5.100E+02 --- DWI R018 Contamination fraction of drinking water 1.000E+00 1.000E+00 --- FDW R018 Contamination fraction of household water not used 1.000E+00 --- FHHW R018 Contamination fraction of livestock water 1.000E+00 1.000E+00 --- FLW R018 Contamination fraction of irrigation water 1.000E+00 1.000E+00 --- FIRW R018 Contamination fraction of aquatic food 1.000E+00 5.000E-01 --- FR9 R018 Contamination fraction of plant food 1.000E+00 -1 --- FPLANT R018 Contamination fraction of meat 1.000E+00 -1 --- FMEAT R018 Contamination fraction of milk 1.000E+00 -1 --- FMILK R019 Livestock fodder intake for meat (kg/day) 2.710E+01 6.800E+01 --- LFI5 R019 Livestock fodder intake for milk (kg/day) 6.320E+01 5.500E+01 --- LFI6 R019 Livestock water intake for meat (L/day) 5.060E+01 5.000E+01 --- LWI5 R019 Livestock water intake for milk (L/day) 6.000E+01 1.600E+02 --- LWI6 R019 Livestock soil intake (kg/day) 5.000E-01 5.000E-01 --- LSI R019 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.000E-04 --- MLFD
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/10/2004 14:35 Page 7 Summary : YR submerged concrete- DCGL, Cm-243 File: Cm-243-concrete_DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R019 Depth of soil mixing layer (m) 2.300E-01 1.500E-01 --- DM R019 Depth of roots (m) 2.050E+00 9.000E-01 --- DROOT R019 Drinking water fraction from ground water 1.000E+00 1.000E+00 --- FGWDW R019 Household water fraction from ground water not used 1.000E+00 --- FGWHH R019 Livestock water fraction from ground water 1.000E+00 1.000E+00 --- FGWLW R019 Irrigation fraction from ground water 1.000E+00 1.000E+00 --- FGWIR R19B Wet weight crop yield for Non-Leafy (kg/m**2) 1.270E+00 7.000E-01 --- YV(1)
R19B Wet weight crop yield for Leafy (kg/m**2) 2.889E+00 1.500E+00 --- YV(2)
R19B Wet weight crop yield for Fodder (kg/m**2) 1.887E+00 1.100E+00 --- YV(3)
R19B Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 --- TE(1)
R19B Growing Season for Leafy (years) 1.230E-01 2.500E-01 --- TE(2)
R19B Growing Season for Fodder (years) 8.200E-02 8.000E-02 --- TE(3)
R19B Translocation Factor for Non-Leafy 1.000E-01 1.000E-01 --- TIV(1)
R19B Translocation Factor for Leafy 1.000E+00 1.000E+00 --- TIV(2)
R19B Translocation Factor for Fodder 1.000E+00 1.000E+00 --- TIV(3)
R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RDRY(1)
R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 --- RDRY(2)
R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RDRY(3)
R19B Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RWET(1)
R19B Wet Foliar Interception Fraction for Leafy 7.000E-01 2.500E-01 --- RWET(2)
R19B Wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RWET(3)
R19B Weathering Removal Constant for Vegetation 2.150E+01 2.000E+01 --- WLAM C14 C-12 concentration in water (g/cm**3) not used 2.000E-05 --- C12WTR C14 C-12 concentration in contaminated soil (g/g) not used 3.000E-02 --- C12CZ C14 Fraction of vegetation carbon from soil not used 2.000E-02 --- CSOIL C14 Fraction of vegetation carbon from air not used 9.800E-01 --- CAIR C14 C-14 evasion layer thickness in soil (m) not used 3.000E-01 --- DMC C14 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 --- EVSN C14 C-12 evasion flux rate from soil (1/sec) not used 1.000E-10 --- REVSN C14 Fraction of grain in beef cattle feed not used 8.000E-01 --- AVFG4 C14 Fraction of grain in milk cow feed not used 2.000E-01 --- AVFG5 C14 DCF correction factor for gaseous forms of C14 not used 8.894E+01 --- CO2F STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 --- STOR_T(1)
STOR Leafy vegetables 1.000E+00 1.000E+00 --- STOR_T(2)
STOR Milk 1.000E+00 1.000E+00 --- STOR_T(3)
STOR Meat and poultry 2.000E+01 2.000E+01 --- STOR_T(4)
STOR Fish 7.000E+00 7.000E+00 --- STOR_T(5)
STOR Crustacea and mollusks 7.000E+00 7.000E+00 --- STOR_T(6)
STOR Well water 1.000E+00 1.000E+00 --- STOR_T(7)
STOR Surface water 1.000E+00 1.000E+00 --- STOR_T(8)
STOR Livestock fodder 4.500E+01 4.500E+01 --- STOR_T(9)
R021 Thickness of building foundation (m) not used 1.500E-01 --- FLOOR1 R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 --- DENSFL R021 Total porosity of the cover material not used 4.000E-01 --- TPCV R021 Total porosity of the building foundation not used 1.000E-01 --- TPFL R021 Volumetric water content of the cover material not used 5.000E-02 --- PH2OCV
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/10/2004 14:35 Page 8 Summary : YR submerged concrete- DCGL, Cm-243 File: Cm-243-concrete_DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R021 Volumetric water content of the foundation not used 3.000E-02 --- PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.000E-06 --- DIFCV R021 in foundation material not used 3.000E-07 --- DIFFL R021 in contaminated zone soil not used 2.000E-06 --- DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.000E+00 --- HMIX R021 Average building air exchange rate (1/hr) not used 5.000E-01 --- REXG R021 Height of the building (room) (m) not used 2.500E+00 --- HRM R021 Building interior area factor not used 0.000E+00 --- FAI R021 Building depth below ground surface (m) not used -1.000E+00 --- DMFL R021 Emanating power of Rn-222 gas not used 2.500E-01 --- EMANA(1)
R021 Emanating power of Rn-220 gas not used 1.500E-01 --- EMANA(2)
TITL Number of graphical time points 32 --- --- NPTS TITL Maximum number of integration points for dose 17 --- --- LYMAX TITL Maximum number of integration points for risk 1 --- --- KYMAX Summary of Pathway Selections Pathway User Selection 1 -- external gamma active 2 -- inhalation (w/o radon) active 3 -- plant ingestion active 4 -- meat ingestion active 5 -- milk ingestion active 6 -- aquatic foods active 7 -- drinking water active 8 -- soil ingestion active 9 -- radon suppressed Find peak pathway doses suppressed
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/10/2004 14:35 Page 9 Summary : YR submerged concrete- DCGL, Cm-243 File: Cm-243-concrete_DCGL.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area: 5020.00 square meters Cm-243 1.000E+00 Thickness: 3.80 meters Cover Depth: 0.00 meters 0
Total Dose TDOSE(t), mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years): 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 TDOSE(t): 4.893E+00 4.979E+00 4.740E+00 3.989E+00 2.438E+00 4.357E-01 4.838E-03 1.373E-03 M(t): 1.957E-01 1.992E-01 1.896E-01 1.596E-01 9.750E-02 1.743E-02 1.935E-04 5.492E-05 0Maximum TDOSE(t): 5.091E+00 mrem/yr at t = 0.1001 +/- 0.0002 years 0
Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.001E-01 years 0 Water Independent Pathways (Inhalation excludes radon) 0 Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Nuclide Cm-243 2.050E-01 0.0403 4.478E-03 0.0009 0.000E+00 0.0000 8.361E-01 0.1642 1.832E-03 0.0004 7.617E-04 0.0001 3.501E-02 0.0069 Total 2.050E-01 0.0403 4.478E-03 0.0009 0.000E+00 0.0000 8.361E-01 0.1642 1.832E-03 0.0004 7.617E-04 0.0001 3.501E-02 0.0069 0
Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.001E-01 years 0 Water Dependent Pathways 0 Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Nuclide Cm-243 2.958E+00 0.5811 6.060E-02 0.0119 0.000E+00 0.0000 9.869E-01 0.1939 1.070E-03 0.0002 7.385E-04 0.0001 5.091E+00 1.0000 Total 2.958E+00 0.5811 6.060E-02 0.0119 0.000E+00 0.0000 9.869E-01 0.1939 1.070E-03 0.0002 7.385E-04 0.0001 5.091E+00 1.0000 0*Sum of all water independent and dependent pathways.
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:31 Page 1 Summary : YR submerged concrete- Sensitivity analysis, Co-60 File : Co-60-concrete_DCGL.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary ... 2 Site-Specific Parameter Summary .......................... 3 Summary of Pathway Selections ............................ 6 Contaminated Zone and Total Dose Summary ................. 7 Total Dose Components Time = 0.000E+00 .................................... 8 Time = 1.000E+00 .................................... 9 Time = 3.000E+00 .................................... 10 Time = 1.000E+01 .................................... 11 Time = 3.000E+01 .................................... 12 Time = 1.000E+02 .................................... 13 Time = 3.000E+02 .................................... 14 Time = 1.000E+03 .................................... 15 Dose/Source Ratios Summed Over All Pathways .............. 16 Single Radionuclide Soil Guidelines ...................... 16 Dose Per Nuclide Summed Over All Pathways ................ 17 Soil Concentration Per Nuclide ........................... 17
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:31 Page 2 Summary : YR submerged concrete- Sensitivity analysis, Co-60 File : Co-60-concrete_DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary File: YR Concrete 0 Current Parameter Menu Parameter Value Default Name B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 Co-60 2.190E-04 2.190E-04 DCF2( 1)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Co-60 2.690E-05 2.690E-05 DCF3( 1)
D-34 Food transfer factors:
D-34 Co-60 , plant/soil concentration ratio, dimensionless 2.500E-03 8.000E-02 RTF( 1,1)
D-34 Co-60 , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 5.850E-02 2.000E-02 RTF( 1,2)
D-34 Co-60 , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 2.000E-03 2.000E-03 RTF( 1,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Co-60 , fish 3.000E+02 3.000E+02 BIOFAC( 1,1)
D-5 Co-60 , crustacea and mollusks 2.000E+02 2.000E+02 BIOFAC( 1,2)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:31 Page 3 Summary : YR submerged concrete- Sensitivity analysis, Co-60 File : Co-60-concrete_DCGL.RAD Site-Specific Parameter Summary 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R011 Area of contaminated zone (m**2) 5.020E+03 1.000E+04 --- AREA R011 Thickness of contaminated zone (m) 3.800E+00 2.000E+00 --- THICK0 R011 Length parallel to aquifer flow (m) 8.000E+01 1.000E+02 --- LCZPAQ R011 Basic radiation dose limit (mrem/yr) 2.500E+01 2.500E+01 --- BRDL R011 Time since placement of material (yr) 0.000E+00 0.000E+00 --- TI R011 Times for calculations (yr) 1.000E+00 1.000E+00 --- T( 2)
R011 Times for calculations (yr) 3.000E+00 3.000E+00 --- T( 3)
R011 Times for calculations (yr) 1.000E+01 1.000E+01 --- T( 4)
R011 Times for calculations (yr) 3.000E+01 3.000E+01 --- T( 5)
R011 Times for calculations (yr) 1.000E+02 1.000E+02 --- T( 6)
R011 Times for calculations (yr) 3.000E+02 3.000E+02 --- T( 7)
R011 Times for calculations (yr) 1.000E+03 1.000E+03 --- T( 8)
R011 Times for calculations (yr) not used 0.000E+00 --- T( 9)
R011 Times for calculations (yr) not used 0.000E+00 --- T(10)
R012 Initial principal radionuclide (pCi/g): Co-60 1.000E+00 0.000E+00 --- S1( 1)
R012 Concentration in groundwater (pCi/L): Co-60 not used 0.000E+00 --- W1( 1)
R013 Cover depth (m) 0.000E+00 0.000E+00 --- COVER0 R013 Density of cover material (g/cm**3) not used 1.500E+00 --- DENSCV R013 Cover depth erosion rate (m/yr) not used 1.000E-03 --- VCV R013 Density of contaminated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSCZ R013 Contaminated zone erosion rate (m/yr) 8.500E-04 1.000E-03 --- VCZ R013 Contaminated zone total porosity 3.000E-01 4.000E-01 --- TPCZ R013 Contaminated zone field capacity 7.000E-02 2.000E-01 --- FCCZ R013 Contaminated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+01 --- HCCZ R013 Contaminated zone b parameter 9.750E-01 5.300E+00 --- BCZ R013 Average annual wind speed (m/sec) 2.030E+00 2.000E+00 --- WIND R013 Humidity in air (g/m**3) not used 8.000E+00 --- HUMID R013 Evapotranspiration coefficient 6.250E-01 5.000E-01 --- EVAPTR R013 Precipitation (m/yr) 1.200E+00 1.000E+00 --- PRECIP R013 Irrigation (m/yr) 4.350E-01 2.000E-01 --- RI R013 Irrigation mode overhead overhead --- IDITCH R013 Runoff coefficient 6.000E-01 2.000E-01 --- RUNOFF R013 Watershed area for nearby stream or pond (m**2) 7.770E+05 1.000E+06 --- WAREA R013 Accuracy for water/soil computations 1.000E-03 1.000E-03 --- EPS R014 Density of saturated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSAQ R014 Saturated zone total porosity 2.800E-01 4.000E-01 --- TPSZ R014 Saturated zone effective porosity 2.100E-01 2.000E-01 --- EPSZ R014 Saturated zone field capacity 7.000E-02 2.000E-01 --- FCSZ R014 Saturated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+02 --- HCSZ R014 Saturated zone hydraulic gradient 1.000E-01 2.000E-02 --- HGWT R014 Saturated zone b parameter 9.750E-01 5.300E+00 --- BSZ R014 Water table drop rate (m/yr) 1.000E-03 1.000E-03 --- VWT R014 Well pump intake depth (m below water table) 1.000E+01 1.000E+01 --- DWIBWT R014 Model: Nondispersion (ND) or Mass-Balance (MB) MB ND --- MODEL R014 Well pumping rate (m**3/yr) 2.500E+02 2.500E+02 --- UW R015 Number of unsaturated zone strata 0 1 --- NS
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:31 Page 4 Summary : YR submerged concrete- Sensitivity analysis, Co-60 File : Co-60-concrete_DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R016 Distribution coefficients for Co-60 R016 Contaminated zone (cm**3/g) 2.820E+02 1.000E+03 --- DCNUCC( 1)
R016 Saturated zone (cm**3/g) 0.000E+00 1.000E+03 --- DCNUCS( 1)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 2.079E-04 ALEACH( 1)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 1)
R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 --- INHALR R017 Mass loading for inhalation (g/m**3) 2.330E-05 1.000E-04 --- MLINH R017 Exposure duration 3.000E+01 3.000E+01 --- ED R017 Shielding factor, inhalation 5.500E-01 4.000E-01 --- SHF3 R017 Shielding factor, external gamma 3.980E-01 7.000E-01 --- SHF1 R017 Fraction of time spent indoors 6.571E-01 5.000E-01 --- FIND R017 Fraction of time spent outdoors (on site) 1.181E-01 2.500E-01 --- FOTD R017 Shape factor flag, external gamma 1.000E+00 1.000E+00 >0 shows circular AREA. FS R017 Radii of shape factor array (used if FS = -1):
R017 Outer annular radius (m), ring 1: not used 5.000E+01 --- RAD_SHAPE( 1)
R017 Outer annular radius (m), ring 2: not used 7.071E+01 --- RAD_SHAPE( 2)
R017 Outer annular radius (m), ring 3: not used 0.000E+00 --- RAD_SHAPE( 3)
R017 Outer annular radius (m), ring 4: not used 0.000E+00 --- RAD_SHAPE( 4)
R017 Outer annular radius (m), ring 5: not used 0.000E+00 --- RAD_SHAPE( 5)
R017 Outer annular radius (m), ring 6: not used 0.000E+00 --- RAD_SHAPE( 6)
R017 Outer annular radius (m), ring 7: not used 0.000E+00 --- RAD_SHAPE( 7)
R017 Outer annular radius (m), ring 8: not used 0.000E+00 --- RAD_SHAPE( 8)
R017 Outer annular radius (m), ring 9: not used 0.000E+00 --- RAD_SHAPE( 9)
R017 Outer annular radius (m), ring 10: not used 0.000E+00 --- RAD_SHAPE(10)
R017 Outer annular radius (m), ring 11: not used 0.000E+00 --- RAD_SHAPE(11)
R017 Outer annular radius (m), ring 12: not used 0.000E+00 --- RAD_SHAPE(12)
R017 Fractions of annular areas within AREA:
R017 Ring 1 not used 1.000E+00 --- FRACA( 1)
R017 Ring 2 not used 2.732E-01 --- FRACA( 2)
R017 Ring 3 not used 0.000E+00 --- FRACA( 3)
R017 Ring 4 not used 0.000E+00 --- FRACA( 4)
R017 Ring 5 not used 0.000E+00 --- FRACA( 5)
R017 Ring 6 not used 0.000E+00 --- FRACA( 6)
R017 Ring 7 not used 0.000E+00 --- FRACA( 7)
R017 Ring 8 not used 0.000E+00 --- FRACA( 8)
R017 Ring 9 not used 0.000E+00 --- FRACA( 9)
R017 Ring 10 not used 0.000E+00 --- FRACA(10)
R017 Ring 11 not used 0.000E+00 --- FRACA(11)
R017 Ring 12 not used 0.000E+00 --- FRACA(12)
R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 --- DIET(1)
R018 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 --- DIET(2)
R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 --- DIET(3)
R018 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 --- DIET(4)
R018 Fish consumption (kg/yr) 2.060E+01 5.400E+00 --- DIET(5)
R018 Other seafood consumption (kg/yr) 9.000E-01 9.000E-01 --- DIET(6)
R018 Soil ingestion rate (g/yr) 1.826E+01 3.650E+01 --- SOIL R018 Drinking water intake (L/yr) 4.785E+02 5.100E+02 --- DWI
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:31 Page 5 Summary : YR submerged concrete- Sensitivity analysis, Co-60 File : Co-60-concrete_DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R018 Contamination fraction of drinking water 1.000E+00 1.000E+00 --- FDW R018 Contamination fraction of household water not used 1.000E+00 --- FHHW R018 Contamination fraction of livestock water 1.000E+00 1.000E+00 --- FLW R018 Contamination fraction of irrigation water 1.000E+00 1.000E+00 --- FIRW R018 Contamination fraction of aquatic food 1.000E+00 5.000E-01 --- FR9 R018 Contamination fraction of plant food 1.000E+00 -1 --- FPLANT R018 Contamination fraction of meat 1.000E+00 -1 --- FMEAT R018 Contamination fraction of milk 1.000E+00 -1 --- FMILK R019 Livestock fodder intake for meat (kg/day) 2.710E+01 6.800E+01 --- LFI5 R019 Livestock fodder intake for milk (kg/day) 6.320E+01 5.500E+01 --- LFI6 R019 Livestock water intake for meat (L/day) 5.060E+01 5.000E+01 --- LWI5 R019 Livestock water intake for milk (L/day) 6.000E+01 1.600E+02 --- LWI6 R019 Livestock soil intake (kg/day) 5.000E-01 5.000E-01 --- LSI R019 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.000E-04 --- MLFD R019 Depth of soil mixing layer (m) 2.300E-01 1.500E-01 --- DM R019 Depth of roots (m) 2.050E+00 9.000E-01 --- DROOT R019 Drinking water fraction from ground water 1.000E+00 1.000E+00 --- FGWDW R019 Household water fraction from ground water not used 1.000E+00 --- FGWHH R019 Livestock water fraction from ground water 1.000E+00 1.000E+00 --- FGWLW R019 Irrigation fraction from ground water 1.000E+00 1.000E+00 --- FGWIR R19B Wet weight crop yield for Non-Leafy (kg/m**2) 1.750E+00 7.000E-01 --- YV(1)
R19B Wet weight crop yield for Leafy (kg/m**2) 2.889E+00 1.500E+00 --- YV(2)
R19B Wet weight crop yield for Fodder (kg/m**2) 1.887E+00 1.100E+00 --- YV(3)
R19B Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 --- TE(1)
R19B Growing Season for Leafy (years) 1.230E-01 2.500E-01 --- TE(2)
R19B Growing Season for Fodder (years) 8.200E-02 8.000E-02 --- TE(3)
R19B Translocation Factor for Non-Leafy 1.000E-01 1.000E-01 --- TIV(1)
R19B Translocation Factor for Leafy 1.000E+00 1.000E+00 --- TIV(2)
R19B Translocation Factor for Fodder 1.000E+00 1.000E+00 --- TIV(3)
R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RDRY(1)
R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 --- RDRY(2)
R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RDRY(3)
R19B Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RWET(1)
R19B Wet Foliar Interception Fraction for Leafy 5.800E-01 2.500E-01 --- RWET(2)
R19B Wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RWET(3)
R19B Weathering Removal Constant for Vegetation 3.300E+01 2.000E+01 --- WLAM C14 C-12 concentration in water (g/cm**3) not used 2.000E-05 --- C12WTR C14 C-12 concentration in contaminated soil (g/g) not used 3.000E-02 --- C12CZ C14 Fraction of vegetation carbon from soil not used 2.000E-02 --- CSOIL C14 Fraction of vegetation carbon from air not used 9.800E-01 --- CAIR C14 C-14 evasion layer thickness in soil (m) not used 3.000E-01 --- DMC C14 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 --- EVSN C14 C-12 evasion flux rate from soil (1/sec) not used 1.000E-10 --- REVSN C14 Fraction of grain in beef cattle feed not used 8.000E-01 --- AVFG4 C14 Fraction of grain in milk cow feed not used 2.000E-01 --- AVFG5 C14 DCF correction factor for gaseous forms of C14 not used 8.894E+01 --- CO2F
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:31 Page 6 Summary : YR submerged concrete- Sensitivity analysis, Co-60 File : Co-60-concrete_DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 --- STOR_T(1)
STOR Leafy vegetables 1.000E+00 1.000E+00 --- STOR_T(2)
STOR Milk 1.000E+00 1.000E+00 --- STOR_T(3)
STOR Meat and poultry 2.000E+01 2.000E+01 --- STOR_T(4)
STOR Fish 7.000E+00 7.000E+00 --- STOR_T(5)
STOR Crustacea and mollusks 7.000E+00 7.000E+00 --- STOR_T(6)
STOR Well water 1.000E+00 1.000E+00 --- STOR_T(7)
STOR Surface water 1.000E+00 1.000E+00 --- STOR_T(8)
STOR Livestock fodder 4.500E+01 4.500E+01 --- STOR_T(9)
R021 Thickness of building foundation (m) not used 1.500E-01 --- FLOOR1 R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 --- DENSFL R021 Total porosity of the cover material not used 4.000E-01 --- TPCV R021 Total porosity of the building foundation not used 1.000E-01 --- TPFL R021 Volumetric water content of the cover material not used 5.000E-02 --- PH2OCV R021 Volumetric water content of the foundation not used 3.000E-02 --- PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.000E-06 --- DIFCV R021 in foundation material not used 3.000E-07 --- DIFFL R021 in contaminated zone soil not used 2.000E-06 --- DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.000E+00 --- HMIX R021 Average building air exchange rate (1/hr) not used 5.000E-01 --- REXG R021 Height of the building (room) (m) not used 2.500E+00 --- HRM R021 Building interior area factor not used 0.000E+00 --- FAI R021 Building depth below ground surface (m) not used -1.000E+00 --- DMFL R021 Emanating power of Rn-222 gas not used 2.500E-01 --- EMANA(1)
R021 Emanating power of Rn-220 gas not used 1.500E-01 --- EMANA(2)
TITL Number of graphical time points 32 --- --- NPTS TITL Maximum number of integration points for dose 17 --- --- LYMAX TITL Maximum number of integration points for risk 1 --- --- KYMAX Summary of Pathway Selections Pathway User Selection 1 -- external gamma active 2 -- inhalation (w/o radon) active 3 -- plant ingestion active 4 -- meat ingestion active 5 -- milk ingestion active 6 -- aquatic foods active 7 -- drinking water active 8 -- soil ingestion active 9 -- radon suppressed Find peak pathway doses suppressed
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:31 Page 7 Summary : YR submerged concrete- Sensitivity analysis, Co-60 File : Co-60-concrete_DCGL.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area: 5020.00 square meters Co-60 1.000E+00 Thickness: 3.80 meters Cover Depth: 0.00 meters 0
Total Dose TDOSE(t), mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years): 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 TDOSE(t): 5.506E+00 4.833E+00 3.714E+00 1.477E+00 1.060E-01 1.050E-05 3.808E-17 0.000E+00 M(t): 2.202E-01 1.933E-01 1.486E-01 5.909E-02 4.241E-03 4.200E-07 1.523E-18 0.000E+00 0Maximum TDOSE(t): 5.506E+00 mrem/yr at t = 0.000E+00 years
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 14:31 Page 8 Summary : YR submerged concrete- Sensitivity analysis, Co-60 File : Co-60-concrete_DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years 0 Water Independent Pathways (Inhalation excludes radon) 0 Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 5.342E+00 0.9702 3.037E-06 0.0000 0.000E+00 0.0000 8.413E-03 0.0015 5.452E-02 0.0099 7.736E-03 0.0014 3.568E-04 0.0001 Total 5.342E+00 0.9702 3.037E-06 0.0000 0.000E+00 0.0000 8.413E-03 0.0015 5.452E-02 0.0099 7.736E-03 0.0014 3.568E-04 0.0001 0
Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years 0 Water Dependent Pathways 0 Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Co-60 4.040E-02 0.0073 3.473E-03 0.0006 0.000E+00 0.0000 7.203E-03 0.0013 3.417E-02 0.0062 7.819E-03 0.0014 5.506E+00 1.0000 Total 4.040E-02 0.0073 3.473E-03 0.0006 0.000E+00 0.0000 7.203E-03 0.0013 3.417E-02 0.0062 7.819E-03 0.0014 5.506E+00 1.0000 0*Sum of all water independent and dependent pathways.
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 18:32 Page 1 Summary : YR submerged concrete- DCGL, Cs-134 File: Cs-134-concrete_DCGL.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary ... 2 Site-Specific Parameter Summary .......................... 3 Summary of Pathway Selections ............................ 6 Contaminated Zone and Total Dose Summary ................. 7 Total Dose Components Time = 0.000E+00 .................................... 8 Time = 1.000E+00 .................................... 9 Time = 3.000E+00 .................................... 10 Time = 1.000E+01 .................................... 11 Time = 3.000E+01 .................................... 12 Time = 1.000E+02 .................................... 13 Time = 3.000E+02 .................................... 14 Time = 1.000E+03 .................................... 15 Dose/Source Ratios Summed Over All Pathways .............. 16 Single Radionuclide Soil Guidelines ...................... 16 Dose Per Nuclide Summed Over All Pathways ................ 17 Soil Concentration Per Nuclide ........................... 17
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 18:32 Page 2 Summary : YR submerged concrete- DCGL, Cs-134 File: Cs-134-concrete_DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary File: YR Concrete 0 Current Parameter Menu Parameter Value Default Name B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 Cs-134 4.630E-05 4.630E-05 DCF2( 1)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Cs-134 7.330E-05 7.330E-05 DCF3( 1)
D-34 Food transfer factors:
D-34 Cs-134 , plant/soil concentration ratio, dimensionless 4.030E-02 4.000E-02 RTF( 1,1)
D-34 Cs-134 , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 6.510E-02 3.000E-02 RTF( 1,2)
D-34 Cs-134 , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.390E-02 8.000E-03 RTF( 1,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Cs-134 , fish 2.000E+03 2.000E+03 BIOFAC( 1,1)
D-5 Cs-134 , crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC( 1,2)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 18:32 Page 3 Summary : YR submerged concrete- DCGL, Cs-134 File: Cs-134-concrete_DCGL.RAD Site-Specific Parameter Summary 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R011 Area of contaminated zone (m**2) 5.020E+03 1.000E+04 --- AREA R011 Thickness of contaminated zone (m) 3.800E+00 2.000E+00 --- THICK0 R011 Length parallel to aquifer flow (m) 8.000E+01 1.000E+02 --- LCZPAQ R011 Basic radiation dose limit (mrem/yr) 2.500E+01 2.500E+01 --- BRDL R011 Time since placement of material (yr) 0.000E+00 0.000E+00 --- TI R011 Times for calculations (yr) 1.000E+00 1.000E+00 --- T( 2)
R011 Times for calculations (yr) 3.000E+00 3.000E+00 --- T( 3)
R011 Times for calculations (yr) 1.000E+01 1.000E+01 --- T( 4)
R011 Times for calculations (yr) 3.000E+01 3.000E+01 --- T( 5)
R011 Times for calculations (yr) 1.000E+02 1.000E+02 --- T( 6)
R011 Times for calculations (yr) 3.000E+02 3.000E+02 --- T( 7)
R011 Times for calculations (yr) 1.000E+03 1.000E+03 --- T( 8)
R011 Times for calculations (yr) not used 0.000E+00 --- T( 9)
R011 Times for calculations (yr) not used 0.000E+00 --- T(10)
R012 Initial principal radionuclide (pCi/g): Cs-134 1.000E+00 0.000E+00 --- S1( 1)
R012 Concentration in groundwater (pCi/L): Cs-134 not used 0.000E+00 --- W1( 1)
R013 Cover depth (m) 0.000E+00 0.000E+00 --- COVER0 R013 Density of cover material (g/cm**3) not used 1.500E+00 --- DENSCV R013 Cover depth erosion rate (m/yr) not used 1.000E-03 --- VCV R013 Density of contaminated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSCZ R013 Contaminated zone erosion rate (m/yr) 8.500E-04 1.000E-03 --- VCZ R013 Contaminated zone total porosity 3.000E-01 4.000E-01 --- TPCZ R013 Contaminated zone field capacity 7.000E-02 2.000E-01 --- FCCZ R013 Contaminated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+01 --- HCCZ R013 Contaminated zone b parameter 9.750E-01 5.300E+00 --- BCZ R013 Average annual wind speed (m/sec) 2.030E+00 2.000E+00 --- WIND R013 Humidity in air (g/m**3) not used 8.000E+00 --- HUMID R013 Evapotranspiration coefficient 6.250E-01 5.000E-01 --- EVAPTR R013 Precipitation (m/yr) 1.200E+00 1.000E+00 --- PRECIP R013 Irrigation (m/yr) 4.350E-01 2.000E-01 --- RI R013 Irrigation mode overhead overhead --- IDITCH R013 Runoff coefficient 6.000E-01 2.000E-01 --- RUNOFF R013 Watershed area for nearby stream or pond (m**2) 7.770E+05 1.000E+06 --- WAREA R013 Accuracy for water/soil computations 1.000E-03 1.000E-03 --- EPS R014 Density of saturated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSAQ R014 Saturated zone total porosity 2.800E-01 4.000E-01 --- TPSZ R014 Saturated zone effective porosity 2.100E-01 2.000E-01 --- EPSZ R014 Saturated zone field capacity 7.000E-02 2.000E-01 --- FCSZ R014 Saturated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+02 --- HCSZ R014 Saturated zone hydraulic gradient 1.000E-01 2.000E-02 --- HGWT R014 Saturated zone b parameter 9.750E-01 5.300E+00 --- BSZ R014 Water table drop rate (m/yr) 1.000E-03 1.000E-03 --- VWT R014 Well pump intake depth (m below water table) 1.000E+01 1.000E+01 --- DWIBWT R014 Model: Nondispersion (ND) or Mass-Balance (MB) MB ND --- MODEL R014 Well pumping rate (m**3/yr) 2.500E+02 2.500E+02 --- UW R015 Number of unsaturated zone strata 0 1 --- NS
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 18:32 Page 4 Summary : YR submerged concrete- DCGL, Cs-134 File: Cs-134-concrete_DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R016 Distribution coefficients for Cs-134 R016 Contaminated zone (cm**3/g) 1.370E+02 1.000E+03 --- DCNUCC( 1)
R016 Saturated zone (cm**3/g) 0.000E+00 1.000E+03 --- DCNUCS( 1)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 4.278E-04 ALEACH( 1)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 1)
R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 --- INHALR R017 Mass loading for inhalation (g/m**3) 2.330E-05 1.000E-04 --- MLINH R017 Exposure duration 3.000E+01 3.000E+01 --- ED R017 Shielding factor, inhalation 5.500E-01 4.000E-01 --- SHF3 R017 Shielding factor, external gamma 3.980E-01 7.000E-01 --- SHF1 R017 Fraction of time spent indoors 6.571E-01 5.000E-01 --- FIND R017 Fraction of time spent outdoors (on site) 1.181E-01 2.500E-01 --- FOTD R017 Shape factor flag, external gamma 1.000E+00 1.000E+00 >0 shows circular AREA. FS R017 Radii of shape factor array (used if FS = -1):
R017 Outer annular radius (m), ring 1: not used 5.000E+01 --- RAD_SHAPE( 1)
R017 Outer annular radius (m), ring 2: not used 7.071E+01 --- RAD_SHAPE( 2)
R017 Outer annular radius (m), ring 3: not used 0.000E+00 --- RAD_SHAPE( 3)
R017 Outer annular radius (m), ring 4: not used 0.000E+00 --- RAD_SHAPE( 4)
R017 Outer annular radius (m), ring 5: not used 0.000E+00 --- RAD_SHAPE( 5)
R017 Outer annular radius (m), ring 6: not used 0.000E+00 --- RAD_SHAPE( 6)
R017 Outer annular radius (m), ring 7: not used 0.000E+00 --- RAD_SHAPE( 7)
R017 Outer annular radius (m), ring 8: not used 0.000E+00 --- RAD_SHAPE( 8)
R017 Outer annular radius (m), ring 9: not used 0.000E+00 --- RAD_SHAPE( 9)
R017 Outer annular radius (m), ring 10: not used 0.000E+00 --- RAD_SHAPE(10)
R017 Outer annular radius (m), ring 11: not used 0.000E+00 --- RAD_SHAPE(11)
R017 Outer annular radius (m), ring 12: not used 0.000E+00 --- RAD_SHAPE(12)
R017 Fractions of annular areas within AREA:
R017 Ring 1 not used 1.000E+00 --- FRACA( 1)
R017 Ring 2 not used 2.732E-01 --- FRACA( 2)
R017 Ring 3 not used 0.000E+00 --- FRACA( 3)
R017 Ring 4 not used 0.000E+00 --- FRACA( 4)
R017 Ring 5 not used 0.000E+00 --- FRACA( 5)
R017 Ring 6 not used 0.000E+00 --- FRACA( 6)
R017 Ring 7 not used 0.000E+00 --- FRACA( 7)
R017 Ring 8 not used 0.000E+00 --- FRACA( 8)
R017 Ring 9 not used 0.000E+00 --- FRACA( 9)
R017 Ring 10 not used 0.000E+00 --- FRACA(10)
R017 Ring 11 not used 0.000E+00 --- FRACA(11)
R017 Ring 12 not used 0.000E+00 --- FRACA(12)
R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 --- DIET(1)
R018 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 --- DIET(2)
R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 --- DIET(3)
R018 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 --- DIET(4)
R018 Fish consumption (kg/yr) 2.060E+01 5.400E+00 --- DIET(5)
R018 Other seafood consumption (kg/yr) 9.000E-01 9.000E-01 --- DIET(6)
R018 Soil ingestion rate (g/yr) 1.826E+01 3.650E+01 --- SOIL R018 Drinking water intake (L/yr) 4.785E+02 5.100E+02 --- DWI R018 Contamination fraction of drinking water 1.000E+00 1.000E+00 --- FDW
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 18:32 Page 5 Summary : YR submerged concrete- DCGL, Cs-134 File: Cs-134-concrete_DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R018 Contamination fraction of household water not used 1.000E+00 --- FHHW R018 Contamination fraction of livestock water 1.000E+00 1.000E+00 --- FLW R018 Contamination fraction of irrigation water 1.000E+00 1.000E+00 --- FIRW R018 Contamination fraction of aquatic food 1.000E+00 5.000E-01 --- FR9 R018 Contamination fraction of plant food 1.000E+00 -1 --- FPLANT R018 Contamination fraction of meat 1.000E+00 -1 --- FMEAT R018 Contamination fraction of milk 1.000E+00 -1 --- FMILK R019 Livestock fodder intake for meat (kg/day) 2.710E+01 6.800E+01 --- LFI5 R019 Livestock fodder intake for milk (kg/day) 6.320E+01 5.500E+01 --- LFI6 R019 Livestock water intake for meat (L/day) 5.060E+01 5.000E+01 --- LWI5 R019 Livestock water intake for milk (L/day) 6.000E+01 1.600E+02 --- LWI6 R019 Livestock soil intake (kg/day) 5.000E-01 5.000E-01 --- LSI R019 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.000E-04 --- MLFD R019 Depth of soil mixing layer (m) 2.300E-01 1.500E-01 --- DM R019 Depth of roots (m) 2.050E+00 9.000E-01 --- DROOT R019 Drinking water fraction from ground water 1.000E+00 1.000E+00 --- FGWDW R019 Household water fraction from ground water not used 1.000E+00 --- FGWHH R019 Livestock water fraction from ground water 1.000E+00 1.000E+00 --- FGWLW R019 Irrigation fraction from ground water 1.000E+00 1.000E+00 --- FGWIR R19B Wet weight crop yield for Non-Leafy (kg/m**2) 1.750E+00 7.000E-01 --- YV(1)
R19B Wet weight crop yield for Leafy (kg/m**2) 2.889E+00 1.500E+00 --- YV(2)
R19B Wet weight crop yield for Fodder (kg/m**2) 1.887E+00 1.100E+00 --- YV(3)
R19B Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 --- TE(1)
R19B Growing Season for Leafy (years) 1.230E-01 2.500E-01 --- TE(2)
R19B Growing Season for Fodder (years) 8.200E-02 8.000E-02 --- TE(3)
R19B Translocation Factor for Non-Leafy 1.000E-01 1.000E-01 --- TIV(1)
R19B Translocation Factor for Leafy 1.000E+00 1.000E+00 --- TIV(2)
R19B Translocation Factor for Fodder 1.000E+00 1.000E+00 --- TIV(3)
R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RDRY(1)
R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 --- RDRY(2)
R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RDRY(3)
R19B Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RWET(1)
R19B Wet Foliar Interception Fraction for Leafy 5.800E-01 2.500E-01 --- RWET(2)
R19B Wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RWET(3)
R19B Weathering Removal Constant for Vegetation 2.150E+01 2.000E+01 --- WLAM C14 C-12 concentration in water (g/cm**3) not used 2.000E-05 --- C12WTR C14 C-12 concentration in contaminated soil (g/g) not used 3.000E-02 --- C12CZ C14 Fraction of vegetation carbon from soil not used 2.000E-02 --- CSOIL C14 Fraction of vegetation carbon from air not used 9.800E-01 --- CAIR C14 C-14 evasion layer thickness in soil (m) not used 3.000E-01 --- DMC C14 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 --- EVSN C14 C-12 evasion flux rate from soil (1/sec) not used 1.000E-10 --- REVSN C14 Fraction of grain in beef cattle feed not used 8.000E-01 --- AVFG4 C14 Fraction of grain in milk cow feed not used 2.000E-01 --- AVFG5 C14 DCF correction factor for gaseous forms of C14 not used 8.894E+01 --- CO2F STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 --- STOR_T(1)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 18:32 Page 6 Summary : YR submerged concrete- DCGL, Cs-134 File: Cs-134-concrete_DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name STOR Leafy vegetables 1.000E+00 1.000E+00 --- STOR_T(2)
STOR Milk 1.000E+00 1.000E+00 --- STOR_T(3)
STOR Meat and poultry 2.000E+01 2.000E+01 --- STOR_T(4)
STOR Fish 7.000E+00 7.000E+00 --- STOR_T(5)
STOR Crustacea and mollusks 7.000E+00 7.000E+00 --- STOR_T(6)
STOR Well water 1.000E+00 1.000E+00 --- STOR_T(7)
STOR Surface water 1.000E+00 1.000E+00 --- STOR_T(8)
STOR Livestock fodder 4.500E+01 4.500E+01 --- STOR_T(9)
R021 Thickness of building foundation (m) not used 1.500E-01 --- FLOOR1 R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 --- DENSFL R021 Total porosity of the cover material not used 4.000E-01 --- TPCV R021 Total porosity of the building foundation not used 1.000E-01 --- TPFL R021 Volumetric water content of the cover material not used 5.000E-02 --- PH2OCV R021 Volumetric water content of the foundation not used 3.000E-02 --- PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.000E-06 --- DIFCV R021 in foundation material not used 3.000E-07 --- DIFFL R021 in contaminated zone soil not used 2.000E-06 --- DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.000E+00 --- HMIX R021 Average building air exchange rate (1/hr) not used 5.000E-01 --- REXG R021 Height of the building (room) (m) not used 2.500E+00 --- HRM R021 Building interior area factor not used 0.000E+00 --- FAI R021 Building depth below ground surface (m) not used -1.000E+00 --- DMFL R021 Emanating power of Rn-222 gas not used 2.500E-01 --- EMANA(1)
R021 Emanating power of Rn-220 gas not used 1.500E-01 --- EMANA(2)
TITL Number of graphical time points 32 --- --- NPTS TITL Maximum number of integration points for dose 17 --- --- LYMAX TITL Maximum number of integration points for risk 1 --- --- KYMAX Summary of Pathway Selections Pathway User Selection 1 -- external gamma active 2 -- inhalation (w/o radon) active 3 -- plant ingestion active 4 -- meat ingestion active 5 -- milk ingestion active 6 -- aquatic foods active 7 -- drinking water active 8 -- soil ingestion active 9 -- radon suppressed Find peak pathway doses suppressed
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 18:32 Page 7 Summary : YR submerged concrete- DCGL, Cs-134 File: Cs-134-concrete_DCGL.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area: 5020.00 square meters Cs-134 1.000E+00 Thickness: 3.80 meters Cover Depth: 0.00 meters 0
Total Dose TDOSE(t), mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years): 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 TDOSE(t): 5.126E+00 3.725E+00 1.900E+00 1.800E-01 2.145E-04 1.253E-14 0.000E+00 0.000E+00 M(t): 2.050E-01 1.490E-01 7.599E-02 7.201E-03 8.581E-06 5.011E-16 0.000E+00 0.000E+00 0Maximum TDOSE(t): 5.126E+00 mrem/yr at t = 0.000E+00 years
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 18:32 Page 8 Summary : YR submerged concrete- DCGL, Cs-134 File: Cs-134-concrete_DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years 0 Water Independent Pathways (Inhalation excludes radon) 0 Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Cs-134 2.812E+00 0.5485 5.818E-07 0.0000 0.000E+00 0.0000 3.346E-01 0.0653 4.201E-01 0.0820 6.144E-01 0.1199 8.810E-04 0.0002 Total 2.812E+00 0.5485 5.818E-07 0.0000 0.000E+00 0.0000 3.346E-01 0.0653 4.201E-01 0.0820 6.144E-01 0.1199 8.810E-04 0.0002 0
Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years 0 Water Dependent Pathways 0 Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Cs-134 2.042E-01 0.0398 1.140E-01 0.0222 0.000E+00 0.0000 5.437E-02 0.0106 2.278E-01 0.0445 3.438E-01 0.0671 5.126E+00 1.0000 Total 2.042E-01 0.0398 1.140E-01 0.0222 0.000E+00 0.0000 5.437E-02 0.0106 2.278E-01 0.0445 3.438E-01 0.0671 5.126E+00 1.0000 0*Sum of all water independent and dependent pathways.
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 18:38 Page 1 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Cs137-concrete-DCGL.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary ... 2 Site-Specific Parameter Summary .......................... 3 Summary of Pathway Selections ............................ 6 Contaminated Zone and Total Dose Summary ................. 7 Total Dose Components Time = 0.000E+00 .................................... 8 Time = 1.000E+00 .................................... 9 Time = 3.000E+00 .................................... 10 Time = 1.000E+01 .................................... 11 Time = 3.000E+01 .................................... 12 Time = 1.000E+02 .................................... 13 Time = 3.000E+02 .................................... 14 Time = 1.000E+03 .................................... 15 Dose/Source Ratios Summed Over All Pathways .............. 16 Single Radionuclide Soil Guidelines ...................... 16 Dose Per Nuclide Summed Over All Pathways ................ 17 Soil Concentration Per Nuclide ........................... 17
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 18:38 Page 2 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Cs137-concrete-DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary File: YR Concrete 0 Current Parameter Menu Parameter Value Default Name B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 Cs-137+D 3.190E-05 3.190E-05 DCF2( 1)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Cs-137+D 5.000E-05 5.000E-05 DCF3( 1)
D-34 Food transfer factors:
D-34 Cs-137+D , plant/soil concentration ratio, dimensionless 5.930E-02 4.000E-02 RTF( 1,1)
D-34 Cs-137+D , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 6.510E-02 3.000E-02 RTF( 1,2)
D-34 Cs-137+D , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.390E-02 8.000E-03 RTF( 1,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Cs-137+D , fish 3.200E+03 2.000E+03 BIOFAC( 1,1)
D-5 Cs-137+D , crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC( 1,2)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 18:38 Page 3 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Cs137-concrete-DCGL.RAD Site-Specific Parameter Summary 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R011 Area of contaminated zone (m**2) 5.020E+03 1.000E+04 --- AREA R011 Thickness of contaminated zone (m) 3.800E+00 2.000E+00 --- THICK0 R011 Length parallel to aquifer flow (m) 8.000E+01 1.000E+02 --- LCZPAQ R011 Basic radiation dose limit (mrem/yr) 2.500E+01 2.500E+01 --- BRDL R011 Time since placement of material (yr) 0.000E+00 0.000E+00 --- TI R011 Times for calculations (yr) 1.000E+00 1.000E+00 --- T( 2)
R011 Times for calculations (yr) 3.000E+00 3.000E+00 --- T( 3)
R011 Times for calculations (yr) 1.000E+01 1.000E+01 --- T( 4)
R011 Times for calculations (yr) 3.000E+01 3.000E+01 --- T( 5)
R011 Times for calculations (yr) 1.000E+02 1.000E+02 --- T( 6)
R011 Times for calculations (yr) 3.000E+02 3.000E+02 --- T( 7)
R011 Times for calculations (yr) 1.000E+03 1.000E+03 --- T( 8)
R011 Times for calculations (yr) not used 0.000E+00 --- T( 9)
R011 Times for calculations (yr) not used 0.000E+00 --- T(10)
R012 Initial principal radionuclide (pCi/g): Cs-137 1.000E+00 0.000E+00 --- S1( 1)
R012 Concentration in groundwater (pCi/L): Cs-137 not used 0.000E+00 --- W1( 1)
R013 Cover depth (m) 0.000E+00 0.000E+00 --- COVER0 R013 Density of cover material (g/cm**3) not used 1.500E+00 --- DENSCV R013 Cover depth erosion rate (m/yr) not used 1.000E-03 --- VCV R013 Density of contaminated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSCZ R013 Contaminated zone erosion rate (m/yr) 8.500E-04 1.000E-03 --- VCZ R013 Contaminated zone total porosity 3.000E-01 4.000E-01 --- TPCZ R013 Contaminated zone field capacity 7.000E-02 2.000E-01 --- FCCZ R013 Contaminated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+01 --- HCCZ R013 Contaminated zone b parameter 9.750E-01 5.300E+00 --- BCZ R013 Average annual wind speed (m/sec) 2.030E+00 2.000E+00 --- WIND R013 Humidity in air (g/m**3) not used 8.000E+00 --- HUMID R013 Evapotranspiration coefficient 6.250E-01 5.000E-01 --- EVAPTR R013 Precipitation (m/yr) 1.200E+00 1.000E+00 --- PRECIP R013 Irrigation (m/yr) 4.350E-01 2.000E-01 --- RI R013 Irrigation mode overhead overhead --- IDITCH R013 Runoff coefficient 6.000E-01 2.000E-01 --- RUNOFF R013 Watershed area for nearby stream or pond (m**2) 7.770E+05 1.000E+06 --- WAREA R013 Accuracy for water/soil computations 1.000E-03 1.000E-03 --- EPS R014 Density of saturated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSAQ R014 Saturated zone total porosity 2.800E-01 4.000E-01 --- TPSZ R014 Saturated zone effective porosity 2.100E-01 2.000E-01 --- EPSZ R014 Saturated zone field capacity 7.000E-02 2.000E-01 --- FCSZ R014 Saturated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+02 --- HCSZ R014 Saturated zone hydraulic gradient 1.000E-01 2.000E-02 --- HGWT R014 Saturated zone b parameter 9.750E-01 5.300E+00 --- BSZ R014 Water table drop rate (m/yr) 1.000E-03 1.000E-03 --- VWT R014 Well pump intake depth (m below water table) 1.000E+01 1.000E+01 --- DWIBWT R014 Model: Nondispersion (ND) or Mass-Balance (MB) MB ND --- MODEL R014 Well pumping rate (m**3/yr) 2.500E+02 2.500E+02 --- UW R015 Number of unsaturated zone strata 0 1 --- NS
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 18:38 Page 4 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Cs137-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R016 Distribution coefficients for Cs-137 R016 Contaminated zone (cm**3/g) 1.370E+02 1.000E+03 --- DCNUCC( 1)
R016 Saturated zone (cm**3/g) 0.000E+00 1.000E+03 --- DCNUCS( 1)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 4.278E-04 ALEACH( 1)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 1)
R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 --- INHALR R017 Mass loading for inhalation (g/m**3) 2.330E-05 1.000E-04 --- MLINH R017 Exposure duration 3.000E+01 3.000E+01 --- ED R017 Shielding factor, inhalation 5.500E-01 4.000E-01 --- SHF3 R017 Shielding factor, external gamma 3.980E-01 7.000E-01 --- SHF1 R017 Fraction of time spent indoors 6.571E-01 5.000E-01 --- FIND R017 Fraction of time spent outdoors (on site) 1.181E-01 2.500E-01 --- FOTD R017 Shape factor flag, external gamma 1.000E+00 1.000E+00 >0 shows circular AREA. FS R017 Radii of shape factor array (used if FS = -1):
R017 Outer annular radius (m), ring 1: not used 5.000E+01 --- RAD_SHAPE( 1)
R017 Outer annular radius (m), ring 2: not used 7.071E+01 --- RAD_SHAPE( 2)
R017 Outer annular radius (m), ring 3: not used 0.000E+00 --- RAD_SHAPE( 3)
R017 Outer annular radius (m), ring 4: not used 0.000E+00 --- RAD_SHAPE( 4)
R017 Outer annular radius (m), ring 5: not used 0.000E+00 --- RAD_SHAPE( 5)
R017 Outer annular radius (m), ring 6: not used 0.000E+00 --- RAD_SHAPE( 6)
R017 Outer annular radius (m), ring 7: not used 0.000E+00 --- RAD_SHAPE( 7)
R017 Outer annular radius (m), ring 8: not used 0.000E+00 --- RAD_SHAPE( 8)
R017 Outer annular radius (m), ring 9: not used 0.000E+00 --- RAD_SHAPE( 9)
R017 Outer annular radius (m), ring 10: not used 0.000E+00 --- RAD_SHAPE(10)
R017 Outer annular radius (m), ring 11: not used 0.000E+00 --- RAD_SHAPE(11)
R017 Outer annular radius (m), ring 12: not used 0.000E+00 --- RAD_SHAPE(12)
R017 Fractions of annular areas within AREA:
R017 Ring 1 not used 1.000E+00 --- FRACA( 1)
R017 Ring 2 not used 2.732E-01 --- FRACA( 2)
R017 Ring 3 not used 0.000E+00 --- FRACA( 3)
R017 Ring 4 not used 0.000E+00 --- FRACA( 4)
R017 Ring 5 not used 0.000E+00 --- FRACA( 5)
R017 Ring 6 not used 0.000E+00 --- FRACA( 6)
R017 Ring 7 not used 0.000E+00 --- FRACA( 7)
R017 Ring 8 not used 0.000E+00 --- FRACA( 8)
R017 Ring 9 not used 0.000E+00 --- FRACA( 9)
R017 Ring 10 not used 0.000E+00 --- FRACA(10)
R017 Ring 11 not used 0.000E+00 --- FRACA(11)
R017 Ring 12 not used 0.000E+00 --- FRACA(12)
R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 --- DIET(1)
R018 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 --- DIET(2)
R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 --- DIET(3)
R018 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 --- DIET(4)
R018 Fish consumption (kg/yr) 2.060E+01 5.400E+00 --- DIET(5)
R018 Other seafood consumption (kg/yr) 9.000E-01 9.000E-01 --- DIET(6)
R018 Soil ingestion rate (g/yr) 1.826E+01 3.650E+01 --- SOIL R018 Drinking water intake (L/yr) 4.785E+02 5.100E+02 --- DWI
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 18:38 Page 5 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Cs137-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R018 Contamination fraction of drinking water 1.000E+00 1.000E+00 --- FDW R018 Contamination fraction of household water not used 1.000E+00 --- FHHW R018 Contamination fraction of livestock water 1.000E+00 1.000E+00 --- FLW R018 Contamination fraction of irrigation water 1.000E+00 1.000E+00 --- FIRW R018 Contamination fraction of aquatic food 1.000E+00 5.000E-01 --- FR9 R018 Contamination fraction of plant food 1.000E+00 -1 --- FPLANT R018 Contamination fraction of meat 1.000E+00 -1 --- FMEAT R018 Contamination fraction of milk 1.000E+00 -1 --- FMILK R019 Livestock fodder intake for meat (kg/day) 2.710E+01 6.800E+01 --- LFI5 R019 Livestock fodder intake for milk (kg/day) 6.320E+01 5.500E+01 --- LFI6 R019 Livestock water intake for meat (L/day) 5.060E+01 5.000E+01 --- LWI5 R019 Livestock water intake for milk (L/day) 6.000E+01 1.600E+02 --- LWI6 R019 Livestock soil intake (kg/day) 5.000E-01 5.000E-01 --- LSI R019 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.000E-04 --- MLFD R019 Depth of soil mixing layer (m) 2.300E-01 1.500E-01 --- DM R019 Depth of roots (m) 2.050E+00 9.000E-01 --- DROOT R019 Drinking water fraction from ground water 1.000E+00 1.000E+00 --- FGWDW R019 Household water fraction from ground water not used 1.000E+00 --- FGWHH R019 Livestock water fraction from ground water 1.000E+00 1.000E+00 --- FGWLW R019 Irrigation fraction from ground water 1.000E+00 1.000E+00 --- FGWIR R19B Wet weight crop yield for Non-Leafy (kg/m**2) 1.750E+00 7.000E-01 --- YV(1)
R19B Wet weight crop yield for Leafy (kg/m**2) 2.889E+00 1.500E+00 --- YV(2)
R19B Wet weight crop yield for Fodder (kg/m**2) 1.887E+00 1.100E+00 --- YV(3)
R19B Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 --- TE(1)
R19B Growing Season for Leafy (years) 1.230E-01 2.500E-01 --- TE(2)
R19B Growing Season for Fodder (years) 8.200E-02 8.000E-02 --- TE(3)
R19B Translocation Factor for Non-Leafy 1.000E-01 1.000E-01 --- TIV(1)
R19B Translocation Factor for Leafy 1.000E+00 1.000E+00 --- TIV(2)
R19B Translocation Factor for Fodder 1.000E+00 1.000E+00 --- TIV(3)
R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RDRY(1)
R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 --- RDRY(2)
R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RDRY(3)
R19B Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RWET(1)
R19B Wet Foliar Interception Fraction for Leafy 5.800E-01 2.500E-01 --- RWET(2)
R19B Wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RWET(3)
R19B Weathering Removal Constant for Vegetation 2.150E+01 2.000E+01 --- WLAM C14 C-12 concentration in water (g/cm**3) not used 2.000E-05 --- C12WTR C14 C-12 concentration in contaminated soil (g/g) not used 3.000E-02 --- C12CZ C14 Fraction of vegetation carbon from soil not used 2.000E-02 --- CSOIL C14 Fraction of vegetation carbon from air not used 9.800E-01 --- CAIR C14 C-14 evasion layer thickness in soil (m) not used 3.000E-01 --- DMC C14 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 --- EVSN C14 C-12 evasion flux rate from soil (1/sec) not used 1.000E-10 --- REVSN C14 Fraction of grain in beef cattle feed not used 8.000E-01 --- AVFG4 C14 Fraction of grain in milk cow feed not used 2.000E-01 --- AVFG5 C14 DCF correction factor for gaseous forms of C14 not used 8.894E+01 --- CO2F
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 18:38 Page 6 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Cs137-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 --- STOR_T(1)
STOR Leafy vegetables 1.000E+00 1.000E+00 --- STOR_T(2)
STOR Milk 1.000E+00 1.000E+00 --- STOR_T(3)
STOR Meat and poultry 2.000E+01 2.000E+01 --- STOR_T(4)
STOR Fish 7.000E+00 7.000E+00 --- STOR_T(5)
STOR Crustacea and mollusks 7.000E+00 7.000E+00 --- STOR_T(6)
STOR Well water 1.000E+00 1.000E+00 --- STOR_T(7)
STOR Surface water 1.000E+00 1.000E+00 --- STOR_T(8)
STOR Livestock fodder 4.500E+01 4.500E+01 --- STOR_T(9)
R021 Thickness of building foundation (m) not used 1.500E-01 --- FLOOR1 R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 --- DENSFL R021 Total porosity of the cover material not used 4.000E-01 --- TPCV R021 Total porosity of the building foundation not used 1.000E-01 --- TPFL R021 Volumetric water content of the cover material not used 5.000E-02 --- PH2OCV R021 Volumetric water content of the foundation not used 3.000E-02 --- PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.000E-06 --- DIFCV R021 in foundation material not used 3.000E-07 --- DIFFL R021 in contaminated zone soil not used 2.000E-06 --- DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.000E+00 --- HMIX R021 Average building air exchange rate (1/hr) not used 5.000E-01 --- REXG R021 Height of the building (room) (m) not used 2.500E+00 --- HRM R021 Building interior area factor not used 0.000E+00 --- FAI R021 Building depth below ground surface (m) not used -1.000E+00 --- DMFL R021 Emanating power of Rn-222 gas not used 2.500E-01 --- EMANA(1)
R021 Emanating power of Rn-220 gas not used 1.500E-01 --- EMANA(2)
TITL Number of graphical time points 32 --- --- NPTS TITL Maximum number of integration points for dose 17 --- --- LYMAX TITL Maximum number of integration points for risk 1 --- --- KYMAX Summary of Pathway Selections Pathway User Selection 1 -- external gamma active 2 -- inhalation (w/o radon) active 3 -- plant ingestion active 4 -- meat ingestion active 5 -- milk ingestion active 6 -- aquatic foods active 7 -- drinking water active 8 -- soil ingestion active 9 -- radon suppressed Find peak pathway doses suppressed
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 18:38 Page 7 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Cs137-concrete-DCGL.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area: 5020.00 square meters Cs-137 1.000E+00 Thickness: 3.80 meters Cover Depth: 0.00 meters 0
Total Dose TDOSE(t), mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years): 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 TDOSE(t): 3.505E+00 3.487E+00 3.326E+00 2.820E+00 1.759E+00 3.375E-01 3.016E-03 2.032E-10 M(t): 1.402E-01 1.395E-01 1.331E-01 1.128E-01 7.038E-02 1.350E-02 1.206E-04 8.129E-12 0Maximum TDOSE(t): 3.505E+00 mrem/yr at t = 0.000E+00 years
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 18:38 Page 8 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Cs137-concrete-DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years 0 Water Independent Pathways (Inhalation excludes radon) 0 Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Cs-137 1.178E+00 0.3363 4.666E-07 0.0000 0.000E+00 0.0000 3.909E-01 0.1116 4.414E-01 0.1259 6.800E-01 0.1940 6.995E-04 0.0002 Total 1.178E+00 0.3363 4.666E-07 0.0000 0.000E+00 0.0000 3.909E-01 0.1116 4.414E-01 0.1259 6.800E-01 0.1940 6.995E-04 0.0002 0
Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years 0 Water Dependent Pathways 0 Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Cs-137 1.635E-01 0.0466 1.459E-01 0.0416 0.000E+00 0.0000 4.376E-02 0.0125 1.837E-01 0.0524 2.763E-01 0.0788 3.505E+00 1.0000 Total 1.635E-01 0.0466 1.459E-01 0.0416 0.000E+00 0.0000 4.376E-02 0.0125 1.837E-01 0.0524 2.763E-01 0.0788 3.505E+00 1.0000 0*Sum of all water independent and dependent pathways.
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:28 Page 1 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Eu152-concrete-DCGL.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary ... 2 Site-Specific Parameter Summary .......................... 3 Summary of Pathway Selections ............................ 7 Contaminated Zone and Total Dose Summary ................. 8 Total Dose Components Time = 0.000E+00 .................................... 9 Time = 1.000E+00 .................................... 10 Time = 3.000E+00 .................................... 11 Time = 1.000E+01 .................................... 12 Time = 3.000E+01 .................................... 13 Time = 1.000E+02 .................................... 14 Time = 3.000E+02 .................................... 15 Time = 1.000E+03 .................................... 16 Dose/Source Ratios Summed Over All Pathways .............. 17 Single Radionuclide Soil Guidelines ...................... 17 Dose Per Nuclide Summed Over All Pathways ................ 18 Soil Concentration Per Nuclide ........................... 18
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:28 Page 2 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Eu152-concrete-DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary File: YR Concrete 0 Current Parameter Menu Parameter Value Default Name B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 Eu-152 2.210E-04 2.210E-04 DCF2( 1)
B-1 Gd-152 2.430E-01 2.430E-01 DCF2( 3)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Eu-152 6.480E-06 6.480E-06 DCF3( 1)
D-1 Gd-152 1.610E-04 1.610E-04 DCF3( 3)
D-34 Food transfer factors:
D-34 Eu-152 , plant/soil concentration ratio, dimensionless 1.870E-04 2.500E-03 RTF( 1,1)
D-34 Eu-152 , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 2.000E-03 2.000E-03 RTF( 1,2)
D-34 Eu-152 , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 6.000E-05 2.000E-05 RTF( 1,3)
D-34 D-34 Gd-152 , plant/soil concentration ratio, dimensionless 1.870E-04 2.500E-03 RTF( 3,1)
D-34 Gd-152 , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 2.000E-03 2.000E-03 RTF( 3,2)
D-34 Gd-152 , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 6.000E-05 2.000E-05 RTF( 3,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Eu-152 , fish 4.900E+01 5.000E+01 BIOFAC( 1,1)
D-5 Eu-152 , crustacea and mollusks 1.000E+03 1.000E+03 BIOFAC( 1,2)
D-5 D-5 Gd-152 , fish 2.500E+01 2.500E+01 BIOFAC( 3,1)
D-5 Gd-152 , crustacea and mollusks 1.000E+03 1.000E+03 BIOFAC( 3,2) 1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:28 Page 3 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Eu152-concrete-DCGL.RAD Site-Specific Parameter Summary 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R011 Area of contaminated zone (m**2) 5.020E+03 1.000E+04 --- AREA R011 Thickness of contaminated zone (m) 3.800E+00 2.000E+00 --- THICK0 R011 Length parallel to aquifer flow (m) 8.000E+01 1.000E+02 --- LCZPAQ R011 Basic radiation dose limit (mrem/yr) 2.500E+01 2.500E+01 --- BRDL R011 Time since placement of material (yr) 0.000E+00 0.000E+00 --- TI R011 Times for calculations (yr) 1.000E+00 1.000E+00 --- T( 2)
R011 Times for calculations (yr) 3.000E+00 3.000E+00 --- T( 3)
R011 Times for calculations (yr) 1.000E+01 1.000E+01 --- T( 4)
R011 Times for calculations (yr) 3.000E+01 3.000E+01 --- T( 5)
R011 Times for calculations (yr) 1.000E+02 1.000E+02 --- T( 6)
R011 Times for calculations (yr) 3.000E+02 3.000E+02 --- T( 7)
R011 Times for calculations (yr) 1.000E+03 1.000E+03 --- T( 8)
R011 Times for calculations (yr) not used 0.000E+00 --- T( 9)
R011 Times for calculations (yr) not used 0.000E+00 --- T(10)
R012 Initial principal radionuclide (pCi/g): Eu-152 1.000E+00 0.000E+00 --- S1( 1)
R012 Concentration in groundwater (pCi/L): Eu-152 not used 0.000E+00 --- W1( 1)
R013 Cover depth (m) 0.000E+00 0.000E+00 --- COVER0 R013 Density of cover material (g/cm**3) not used 1.500E+00 --- DENSCV R013 Cover depth erosion rate (m/yr) not used 1.000E-03 --- VCV R013 Density of contaminated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSCZ R013 Contaminated zone erosion rate (m/yr) 8.500E-04 1.000E-03 --- VCZ R013 Contaminated zone total porosity 3.000E-01 4.000E-01 --- TPCZ R013 Contaminated zone field capacity 7.000E-02 2.000E-01 --- FCCZ R013 Contaminated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+01 --- HCCZ R013 Contaminated zone b parameter 9.750E-01 5.300E+00 --- BCZ R013 Average annual wind speed (m/sec) 2.030E+00 2.000E+00 --- WIND R013 Humidity in air (g/m**3) not used 8.000E+00 --- HUMID R013 Evapotranspiration coefficient 6.250E-01 5.000E-01 --- EVAPTR R013 Precipitation (m/yr) 1.200E+00 1.000E+00 --- PRECIP R013 Irrigation (m/yr) 4.350E-01 2.000E-01 --- RI R013 Irrigation mode overhead overhead --- IDITCH R013 Runoff coefficient 6.000E-01 2.000E-01 --- RUNOFF R013 Watershed area for nearby stream or pond (m**2) 7.770E+05 1.000E+06 --- WAREA R013 Accuracy for water/soil computations 1.000E-03 1.000E-03 --- EPS R014 Density of saturated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSAQ
R014 Saturated zone total porosity 2.800E-01 4.000E-01 --- TPSZ R014 Saturated zone effective porosity 2.100E-01 2.000E-01 --- EPSZ R014 Saturated zone field capacity 7.000E-02 2.000E-01 --- FCSZ R014 Saturated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+02 --- HCSZ R014 Saturated zone hydraulic gradient 1.000E-01 2.000E-02 --- HGWT R014 Saturated zone b parameter 9.750E-01 5.300E+00 --- BSZ R014 Water table drop rate (m/yr) 1.000E-03 1.000E-03 --- VWT R014 Well pump intake depth (m below water table) 1.000E+01 1.000E+01 --- DWIBWT R014 Model: Nondispersion (ND) or Mass-Balance (MB) MB ND --- MODEL R014 Well pumping rate (m**3/yr) 2.500E+02 2.500E+02 --- UW R015 Number of unsaturated zone strata 0 1 --- NS
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:28 Page 4 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Eu152-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R016 Distribution coefficients for Eu-152 R016 Contaminated zone (cm**3/g) 1.000E+03 -1.000E+00 --- DCNUCC( 1)
R016 Saturated zone (cm**3/g) 0.000E+00 -1.000E+00 --- DCNUCS( 1)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 5.863E-05 ALEACH( 1)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 1)
R016 Distribution coefficients for daughter Gd-152 R016 Contaminated zone (cm**3/g) 1.000E+03 -1.000E+00 --- DCNUCC( 3)
R016 Saturated zone (cm**3/g) 0.000E+00 -1.000E+00 --- DCNUCS( 3)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 5.863E-05 ALEACH( 3)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 3)
R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 --- INHALR R017 Mass loading for inhalation (g/m**3) 2.330E-05 1.000E-04 --- MLINH R017 Exposure duration 3.000E+01 3.000E+01 --- ED R017 Shielding factor, inhalation 5.500E-01 4.000E-01 --- SHF3 R017 Shielding factor, external gamma 3.980E-01 7.000E-01 --- SHF1 R017 Fraction of time spent indoors 6.571E-01 5.000E-01 --- FIND R017 Fraction of time spent outdoors (on site) 1.181E-01 2.500E-01 --- FOTD R017 Shape factor flag, external gamma 1.000E+00 1.000E+00 >0 shows circular AREA. FS R017 Radii of shape factor array (used if FS = -1):
R017 Outer annular radius (m), ring 1: not used 5.000E+01 --- RAD_SHAPE( 1)
R017 Outer annular radius (m), ring 2: not used 7.071E+01 --- RAD_SHAPE( 2)
R017 Outer annular radius (m), ring 3: not used 0.000E+00 --- RAD_SHAPE( 3)
R017 Outer annular radius (m), ring 4: not used 0.000E+00 --- RAD_SHAPE( 4)
R017 Outer annular radius (m), ring 5: not used 0.000E+00 --- RAD_SHAPE( 5)
R017 Outer annular radius (m), ring 6: not used 0.000E+00 --- RAD_SHAPE( 6)
R017 Outer annular radius (m), ring 7: not used 0.000E+00 --- RAD_SHAPE( 7)
R017 Outer annular radius (m), ring 8: not used 0.000E+00 --- RAD_SHAPE( 8)
R017 Outer annular radius (m), ring 9: not used 0.000E+00 --- RAD_SHAPE( 9)
R017 Outer annular radius (m), ring 10: not used 0.000E+00 --- RAD_SHAPE(10)
R017 Outer annular radius (m), ring 11: not used 0.000E+00 --- RAD_SHAPE(11)
R017 Outer annular radius (m), ring 12: not used 0.000E+00 --- RAD_SHAPE(12)
R017 Fractions of annular areas within AREA:
R017 Ring 1 not used 1.000E+00 --- FRACA( 1)
R017 Ring 2 not used 2.732E-01 --- FRACA( 2)
R017 Ring 3 not used 0.000E+00 --- FRACA( 3)
R017 Ring 4 not used 0.000E+00 --- FRACA( 4)
R017 Ring 5 not used 0.000E+00 --- FRACA( 5)
R017 Ring 6 not used 0.000E+00 --- FRACA( 6)
R017 Ring 7 not used 0.000E+00 --- FRACA( 7)
R017 Ring 8 not used 0.000E+00 --- FRACA( 8)
R017 Ring 9 not used 0.000E+00 --- FRACA( 9)
R017 Ring 10 not used 0.000E+00 --- FRACA(10)
R017 Ring 11 not used 0.000E+00 --- FRACA(11)
R017 Ring 12 not used 0.000E+00 --- FRACA(12)
R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 --- DIET(1)
R018 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 --- DIET(2)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:28 Page 5 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Eu152-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 --- DIET(3)
R018 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 --- DIET(4)
R018 Fish consumption (kg/yr) 2.060E+01 5.400E+00 --- DIET(5)
R018 Other seafood consumption (kg/yr) 9.000E-01 9.000E-01 --- DIET(6)
R018 Soil ingestion rate (g/yr) 1.826E+01 3.650E+01 --- SOIL R018 Drinking water intake (L/yr) 4.785E+02 5.100E+02 --- DWI R018 Contamination fraction of drinking water 1.000E+00 1.000E+00 --- FDW R018 Contamination fraction of household water not used 1.000E+00 --- FHHW R018 Contamination fraction of livestock water 1.000E+00 1.000E+00 --- FLW R018 Contamination fraction of irrigation water 1.000E+00 1.000E+00 --- FIRW R018 Contamination fraction of aquatic food 1.000E+00 5.000E-01 --- FR9 R018 Contamination fraction of plant food 1.000E+00 -1 --- FPLANT R018 Contamination fraction of meat 1.000E+00 -1 --- FMEAT R018 Contamination fraction of milk 1.000E+00 -1 --- FMILK R019 Livestock fodder intake for meat (kg/day) 2.710E+01 6.800E+01 --- LFI5 R019 Livestock fodder intake for milk (kg/day) 6.320E+01 5.500E+01 --- LFI6 R019 Livestock water intake for meat (L/day) 5.060E+01 5.000E+01 --- LWI5 R019 Livestock water intake for milk (L/day) 6.000E+01 1.600E+02 --- LWI6 R019 Livestock soil intake (kg/day) 5.000E-01 5.000E-01 --- LSI R019 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.000E-04 --- MLFD R019 Depth of soil mixing layer (m) 2.300E-01 1.500E-01 --- DM R019 Depth of roots (m) 2.050E+00 9.000E-01 --- DROOT R019 Drinking water fraction from ground water 1.000E+00 1.000E+00 --- FGWDW R019 Household water fraction from ground water not used 1.000E+00 --- FGWHH R019 Livestock water fraction from ground water 1.000E+00 1.000E+00 --- FGWLW R019 Irrigation fraction from ground water 1.000E+00 1.000E+00 --- FGWIR R19B Wet weight crop yield for Non-Leafy (kg/m**2) 1.750E+00 7.000E-01 --- YV(1)
R19B Wet weight crop yield for Leafy (kg/m**2) 2.889E+00 1.500E+00 --- YV(2)
R19B Wet weight crop yield for Fodder (kg/m**2) 1.887E+00 1.100E+00 --- YV(3)
R19B Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 --- TE(1)
R19B Growing Season for Leafy (years) 1.230E-01 2.500E-01 --- TE(2)
R19B Growing Season for Fodder (years) 8.200E-02 8.000E-02 --- TE(3)
R19B Translocation Factor for Non-Leafy 1.000E-01 1.000E-01 --- TIV(1)
R19B Translocation Factor for Leafy 1.000E+00 1.000E+00 --- TIV(2)
R19B Translocation Factor for Fodder 1.000E+00 1.000E+00 --- TIV(3)
R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RDRY(1)
R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 --- RDRY(2)
R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RDRY(3)
R19B Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RWET(1)
R19B Wet Foliar Interception Fraction for Leafy 5.800E-01 2.500E-01 --- RWET(2)
R19B Wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RWET(3)
R19B Weathering Removal Constant for Vegetation 3.300E+01 2.000E+01 --- WLAM C14 C-12 concentration in water (g/cm**3) not used 2.000E-05 --- C12WTR C14 C-12 concentration in contaminated soil (g/g) not used 3.000E-02 --- C12CZ C14 Fraction of vegetation carbon from soil not used 2.000E-02 --- CSOIL C14 Fraction of vegetation carbon from air not used 9.800E-01 --- CAIR C14 C-14 evasion layer thickness in soil (m) not used 3.000E-01 --- DMC
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:28 Page 6 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Eu152-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name C14 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 --- EVSN C14 C-12 evasion flux rate from soil (1/sec) not used 1.000E-10 --- REVSN C14 Fraction of grain in beef cattle feed not used 8.000E-01 --- AVFG4 C14 Fraction of grain in milk cow feed not used 2.000E-01 --- AVFG5 C14 DCF correction factor for gaseous forms of C14 not used 8.894E+01 --- CO2F STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 --- STOR_T(1)
STOR Leafy vegetables 1.000E+00 1.000E+00 --- STOR_T(2)
STOR Milk 1.000E+00 1.000E+00 --- STOR_T(3)
STOR Meat and poultry 2.000E+01 2.000E+01 --- STOR_T(4)
STOR Fish 7.000E+00 7.000E+00 --- STOR_T(5)
STOR Crustacea and mollusks 7.000E+00 7.000E+00 --- STOR_T(6)
STOR Well water 1.000E+00 1.000E+00 --- STOR_T(7)
STOR Surface water 1.000E+00 1.000E+00 --- STOR_T(8)
STOR Livestock fodder 4.500E+01 4.500E+01 --- STOR_T(9)
R021 Thickness of building foundation (m) not used 1.500E-01 --- FLOOR1 R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 --- DENSFL R021 Total porosity of the cover material not used 4.000E-01 --- TPCV R021 Total porosity of the building foundation not used 1.000E-01 --- TPFL R021 Volumetric water content of the cover material not used 5.000E-02 --- PH2OCV R021 Volumetric water content of the foundation not used 3.000E-02 --- PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.000E-06 --- DIFCV R021 in foundation material not used 3.000E-07 --- DIFFL R021 in contaminated zone soil not used 2.000E-06 --- DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.000E+00 --- HMIX R021 Average building air exchange rate (1/hr) not used 5.000E-01 --- REXG R021 Height of the building (room) (m) not used 2.500E+00 --- HRM R021 Building interior area factor not used 0.000E+00 --- FAI R021 Building depth below ground surface (m) not used -1.000E+00 --- DMFL R021 Emanating power of Rn-222 gas not used 2.500E-01 --- EMANA(1)
R021 Emanating power of Rn-220 gas not used 1.500E-01 --- EMANA(2)
TITL Number of graphical time points 32 --- --- NPTS TITL Maximum number of integration points for dose 17 --- --- LYMAX TITL Maximum number of integration points for risk 1 --- --- KYMAX
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:28 Page 7 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Eu152-concrete-DCGL.RAD Summary of Pathway Selections Pathway User Selection 1 -- external gamma active 2 -- inhalation (w/o radon) active 3 -- plant ingestion active 4 -- meat ingestion active 5 -- milk ingestion active 6 -- aquatic foods active 7 -- drinking water active 8 -- soil ingestion active 9 -- radon suppressed Find peak pathway doses suppressed
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:28 Page 8 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Eu152-concrete-DCGL.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area: 5020.00 square meters Eu-152 1.000E+00 Thickness: 3.80 meters Cover Depth: 0.00 meters 0
Total Dose TDOSE(t), mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years): 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 TDOSE(t): 2.407E+00 2.285E+00 2.059E+00 1.430E+00 5.049E-01 1.320E-02 3.971E-07 3.102E-15 M(t): 9.626E-02 9.139E-02 8.235E-02 5.720E-02 2.019E-02 5.280E-04 1.588E-08 1.241E-16 0Maximum TDOSE(t): 2.407E+00 mrem/yr at t = 0.000E+00 years
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:28 Page 9 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Eu152-concrete-DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years 0 Water Independent Pathways (Inhalation excludes radon) 0 Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Eu-152 2.402E+00 0.9982 3.187E-06 0.0000 0.000E+00 0.0000 1.593E-04 0.0001 4.155E-04 0.0002 4.524E-05 0.0000 8.938E-05 0.0000 Total 2.402E+00 0.9982 3.187E-06 0.0000 0.000E+00 0.0000 1.593E-04 0.0001 4.155E-04 0.0002 4.524E-05 0.0000 8.938E-05 0.0000 0
Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years 0 Water Dependent Pathways 0 Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Eu-152 2.860E-03 0.0012 7.383E-05 0.0000 0.000E+00 0.0000 5.095E-04 0.0002 8.282E-05 0.0000 1.662E-05 0.0000 2.407E+00 1.0000 Total 2.860E-03 0.0012 7.383E-05 0.0000 0.000E+00 0.0000 5.095E-04 0.0002 8.282E-05 0.0000 1.662E-05 0.0000 2.407E+00 1.0000 0*Sum of all water independent and dependent pathways.
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:31 Page 1 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Eu154-concrete-DCGL.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary ... 2 Site-Specific Parameter Summary .......................... 3 Summary of Pathway Selections ............................ 6 Contaminated Zone and Total Dose Summary ................. 7 Total Dose Components Time = 0.000E+00 .................................... 8 Time = 1.000E+00 .................................... 9 Time = 3.000E+00 .................................... 10 Time = 1.000E+01 .................................... 11 Time = 3.000E+01 .................................... 12 Time = 1.000E+02 .................................... 13 Time = 3.000E+02 .................................... 14 Time = 1.000E+03 .................................... 15 Dose/Source Ratios Summed Over All Pathways .............. 16 Single Radionuclide Soil Guidelines ...................... 16 Dose Per Nuclide Summed Over All Pathways ................ 17 Soil Concentration Per Nuclide ........................... 17
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:31 Page 2 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Eu154-concrete-DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary File: YR Concrete 0 Current Parameter Menu Parameter Value Default Name B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 Eu-154 2.860E-04 2.860E-04 DCF2( 1)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Eu-154 9.550E-06 9.550E-06 DCF3( 1)
D-34 Food transfer factors:
D-34 Eu-154 , plant/soil concentration ratio, dimensionless 1.870E-04 2.500E-03 RTF( 1,1)
D-34 Eu-154 , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 2.000E-03 2.000E-03 RTF( 1,2)
D-34 Eu-154 , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 6.000E-05 2.000E-05 RTF( 1,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Eu-154 , fish 4.900E+01 5.000E+01 BIOFAC( 1,1)
D-5 Eu-154 , crustacea and mollusks 1.000E+03 1.000E+03 BIOFAC( 1,2)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:31 Page 3 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Eu154-concrete-DCGL.RAD Site-Specific Parameter Summary 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R011 Area of contaminated zone (m**2) 5.020E+03 1.000E+04 --- AREA R011 Thickness of contaminated zone (m) 3.800E+00 2.000E+00 --- THICK0 R011 Length parallel to aquifer flow (m) 8.000E+01 1.000E+02 --- LCZPAQ R011 Basic radiation dose limit (mrem/yr) 2.500E+01 2.500E+01 --- BRDL R011 Time since placement of material (yr) 0.000E+00 0.000E+00 --- TI R011 Times for calculations (yr) 1.000E+00 1.000E+00 --- T( 2)
R011 Times for calculations (yr) 3.000E+00 3.000E+00 --- T( 3)
R011 Times for calculations (yr) 1.000E+01 1.000E+01 --- T( 4)
R011 Times for calculations (yr) 3.000E+01 3.000E+01 --- T( 5)
R011 Times for calculations (yr) 1.000E+02 1.000E+02 --- T( 6)
R011 Times for calculations (yr) 3.000E+02 3.000E+02 --- T( 7)
R011 Times for calculations (yr) 1.000E+03 1.000E+03 --- T( 8)
R011 Times for calculations (yr) not used 0.000E+00 --- T( 9)
R011 Times for calculations (yr) not used 0.000E+00 --- T(10)
R012 Initial principal radionuclide (pCi/g): Eu-154 1.000E+00 0.000E+00 --- S1( 1)
R012 Concentration in groundwater (pCi/L): Eu-154 not used 0.000E+00 --- W1( 1)
R013 Cover depth (m) 0.000E+00 0.000E+00 --- COVER0 R013 Density of cover material (g/cm**3) not used 1.500E+00 --- DENSCV R013 Cover depth erosion rate (m/yr) not used 1.000E-03 --- VCV R013 Density of contaminated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSCZ R013 Contaminated zone erosion rate (m/yr) 8.500E-04 1.000E-03 --- VCZ R013 Contaminated zone total porosity 3.000E-01 4.000E-01 --- TPCZ R013 Contaminated zone field capacity 7.000E-02 2.000E-01 --- FCCZ R013 Contaminated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+01 --- HCCZ R013 Contaminated zone b parameter 9.750E-01 5.300E+00 --- BCZ R013 Average annual wind speed (m/sec) 2.030E+00 2.000E+00 --- WIND R013 Humidity in air (g/m**3) not used 8.000E+00 --- HUMID R013 Evapotranspiration coefficient 6.250E-01 5.000E-01 --- EVAPTR R013 Precipitation (m/yr) 1.200E+00 1.000E+00 --- PRECIP R013 Irrigation (m/yr) 4.350E-01 2.000E-01 --- RI R013 Irrigation mode overhead overhead --- IDITCH R013 Runoff coefficient 6.000E-01 2.000E-01 --- RUNOFF R013 Watershed area for nearby stream or pond (m**2) 7.770E+05 1.000E+06 --- WAREA R013 Accuracy for water/soil computations 1.000E-03 1.000E-03 --- EPS R014 Density of saturated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSAQ R014 Saturated zone total porosity 2.800E-01 4.000E-01 --- TPSZ R014 Saturated zone effective porosity 2.100E-01 2.000E-01 --- EPSZ R014 Saturated zone field capacity 7.000E-02 2.000E-01 --- FCSZ R014 Saturated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+02 --- HCSZ R014 Saturated zone hydraulic gradient 1.000E-01 2.000E-02 --- HGWT R014 Saturated zone b parameter 9.750E-01 5.300E+00 --- BSZ R014 Water table drop rate (m/yr) 1.000E-03 1.000E-03 --- VWT R014 Well pump intake depth (m below water table) 1.000E+01 1.000E+01 --- DWIBWT R014 Model: Nondispersion (ND) or Mass-Balance (MB) MB ND --- MODEL R014 Well pumping rate (m**3/yr) 2.500E+02 2.500E+02 --- UW R015 Number of unsaturated zone strata 0 1 --- NS
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:31 Page 4 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Eu154-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R016 Distribution coefficients for Eu-154 R016 Contaminated zone (cm**3/g) 1.000E+03 -1.000E+00 --- DCNUCC( 1)
R016 Saturated zone (cm**3/g) 0.000E+00 -1.000E+00 --- DCNUCS( 1)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 5.863E-05 ALEACH( 1)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 1)
R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 --- INHALR R017 Mass loading for inhalation (g/m**3) 2.330E-05 1.000E-04 --- MLINH R017 Exposure duration 3.000E+01 3.000E+01 --- ED R017 Shielding factor, inhalation 5.500E-01 4.000E-01 --- SHF3 R017 Shielding factor, external gamma 3.980E-01 7.000E-01 --- SHF1 R017 Fraction of time spent indoors 6.571E-01 5.000E-01 --- FIND R017 Fraction of time spent outdoors (on site) 1.181E-01 2.500E-01 --- FOTD R017 Shape factor flag, external gamma 1.000E+00 1.000E+00 >0 shows circular AREA. FS R017 Radii of shape factor array (used if FS = -1):
R017 Outer annular radius (m), ring 1: not used 5.000E+01 --- RAD_SHAPE( 1)
R017 Outer annular radius (m), ring 2: not used 7.071E+01 --- RAD_SHAPE( 2)
R017 Outer annular radius (m), ring 3: not used 0.000E+00 --- RAD_SHAPE( 3)
R017 Outer annular radius (m), ring 4: not used 0.000E+00 --- RAD_SHAPE( 4)
R017 Outer annular radius (m), ring 5: not used 0.000E+00 --- RAD_SHAPE( 5)
R017 Outer annular radius (m), ring 6: not used 0.000E+00 --- RAD_SHAPE( 6)
R017 Outer annular radius (m), ring 7: not used 0.000E+00 --- RAD_SHAPE( 7)
R017 Outer annular radius (m), ring 8: not used 0.000E+00 --- RAD_SHAPE( 8)
R017 Outer annular radius (m), ring 9: not used 0.000E+00 --- RAD_SHAPE( 9)
R017 Outer annular radius (m), ring 10: not used 0.000E+00 --- RAD_SHAPE(10)
R017 Outer annular radius (m), ring 11: not used 0.000E+00 --- RAD_SHAPE(11)
R017 Outer annular radius (m), ring 12: not used 0.000E+00 --- RAD_SHAPE(12)
R017 Fractions of annular areas within AREA:
R017 Ring 1 not used 1.000E+00 --- FRACA( 1)
R017 Ring 2 not used 2.732E-01 --- FRACA( 2)
R017 Ring 3 not used 0.000E+00 --- FRACA( 3)
R017 Ring 4 not used 0.000E+00 --- FRACA( 4)
R017 Ring 5 not used 0.000E+00 --- FRACA( 5)
R017 Ring 6 not used 0.000E+00 --- FRACA( 6)
R017 Ring 7 not used 0.000E+00 --- FRACA( 7)
R017 Ring 8 not used 0.000E+00 --- FRACA( 8)
R017 Ring 9 not used 0.000E+00 --- FRACA( 9)
R017 Ring 10 not used 0.000E+00 --- FRACA(10)
R017 Ring 11 not used 0.000E+00 --- FRACA(11)
R017 Ring 12 not used 0.000E+00 --- FRACA(12)
R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 --- DIET(1)
R018 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 --- DIET(2)
R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 --- DIET(3)
R018 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 --- DIET(4)
R018 Fish consumption (kg/yr) 2.060E+01 5.400E+00 --- DIET(5)
R018 Other seafood consumption (kg/yr) 9.000E-01 9.000E-01 --- DIET(6)
R018 Soil ingestion rate (g/yr) 1.826E+01 3.650E+01 --- SOIL R018 Drinking water intake (L/yr) 4.785E+02 5.100E+02 --- DWI
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:31 Page 5 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Eu154-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R018 Contamination fraction of drinking water 1.000E+00 1.000E+00 --- FDW R018 Contamination fraction of household water not used 1.000E+00 --- FHHW R018 Contamination fraction of livestock water 1.000E+00 1.000E+00 --- FLW R018 Contamination fraction of irrigation water 1.000E+00 1.000E+00 --- FIRW R018 Contamination fraction of aquatic food 1.000E+00 5.000E-01 --- FR9 R018 Contamination fraction of plant food 1.000E+00 -1 --- FPLANT R018 Contamination fraction of meat 1.000E+00 -1 --- FMEAT R018 Contamination fraction of milk 1.000E+00 -1 --- FMILK R019 Livestock fodder intake for meat (kg/day) 2.710E+01 6.800E+01 --- LFI5 R019 Livestock fodder intake for milk (kg/day) 6.320E+01 5.500E+01 --- LFI6 R019 Livestock water intake for meat (L/day) 5.060E+01 5.000E+01 --- LWI5 R019 Livestock water intake for milk (L/day) 6.000E+01 1.600E+02 --- LWI6 R019 Livestock soil intake (kg/day) 5.000E-01 5.000E-01 --- LSI R019 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.000E-04 --- MLFD R019 Depth of soil mixing layer (m) 2.300E-01 1.500E-01 --- DM R019 Depth of roots (m) 2.050E+00 9.000E-01 --- DROOT R019 Drinking water fraction from ground water 1.000E+00 1.000E+00 --- FGWDW R019 Household water fraction from ground water not used 1.000E+00 --- FGWHH R019 Livestock water fraction from ground water 1.000E+00 1.000E+00 --- FGWLW R019 Irrigation fraction from ground water 1.000E+00 1.000E+00 --- FGWIR R19B Wet weight crop yield for Non-Leafy (kg/m**2) 1.750E+00 7.000E-01 --- YV(1)
R19B Wet weight crop yield for Leafy (kg/m**2) 2.889E+00 1.500E+00 --- YV(2)
R19B Wet weight crop yield for Fodder (kg/m**2) 1.887E+00 1.100E+00 --- YV(3)
R19B Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 --- TE(1)
R19B Growing Season for Leafy (years) 1.230E-01 2.500E-01 --- TE(2)
R19B Growing Season for Fodder (years) 8.200E-02 8.000E-02 --- TE(3)
R19B Translocation Factor for Non-Leafy 1.000E-01 1.000E-01 --- TIV(1)
R19B Translocation Factor for Leafy 1.000E+00 1.000E+00 --- TIV(2)
R19B Translocation Factor for Fodder 1.000E+00 1.000E+00 --- TIV(3)
R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RDRY(1)
R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 --- RDRY(2)
R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RDRY(3)
R19B Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RWET(1)
R19B Wet Foliar Interception Fraction for Leafy 5.800E-01 2.500E-01 --- RWET(2)
R19B Wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RWET(3)
R19B Weathering Removal Constant for Vegetation 3.300E+01 2.000E+01 --- WLAM C14 C-12 concentration in water (g/cm**3) not used 2.000E-05 --- C12WTR C14 C-12 concentration in contaminated soil (g/g) not used 3.000E-02 --- C12CZ C14 Fraction of vegetation carbon from soil not used 2.000E-02 --- CSOIL C14 Fraction of vegetation carbon from air not used 9.800E-01 --- CAIR C14 C-14 evasion layer thickness in soil (m) not used 3.000E-01 --- DMC C14 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 --- EVSN C14 C-12 evasion flux rate from soil (1/sec) not used 1.000E-10 --- REVSN C14 Fraction of grain in beef cattle feed not used 8.000E-01 --- AVFG4 C14 Fraction of grain in milk cow feed not used 2.000E-01 --- AVFG5 C14 DCF correction factor for gaseous forms of C14 not used 8.894E+01 --- CO2F
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:31 Page 6 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Eu154-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 --- STOR_T(1)
STOR Leafy vegetables 1.000E+00 1.000E+00 --- STOR_T(2)
STOR Milk 1.000E+00 1.000E+00 --- STOR_T(3)
STOR Meat and poultry 2.000E+01 2.000E+01 --- STOR_T(4)
STOR Fish 7.000E+00 7.000E+00 --- STOR_T(5)
STOR Crustacea and mollusks 7.000E+00 7.000E+00 --- STOR_T(6)
STOR Well water 1.000E+00 1.000E+00 --- STOR_T(7)
STOR Surface water 1.000E+00 1.000E+00 --- STOR_T(8)
STOR Livestock fodder 4.500E+01 4.500E+01 --- STOR_T(9)
R021 Thickness of building foundation (m) not used 1.500E-01 --- FLOOR1 R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 --- DENSFL R021 Total porosity of the cover material not used 4.000E-01 --- TPCV R021 Total porosity of the building foundation not used 1.000E-01 --- TPFL R021 Volumetric water content of the cover material not used 5.000E-02 --- PH2OCV R021 Volumetric water content of the foundation not used 3.000E-02 --- PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.000E-06 --- DIFCV R021 in foundation material not used 3.000E-07 --- DIFFL R021 in contaminated zone soil not used 2.000E-06 --- DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.000E+00 --- HMIX R021 Average building air exchange rate (1/hr) not used 5.000E-01 --- REXG R021 Height of the building (room) (m) not used 2.500E+00 --- HRM R021 Building interior area factor not used 0.000E+00 --- FAI R021 Building depth below ground surface (m) not used -1.000E+00 --- DMFL R021 Emanating power of Rn-222 gas not used 2.500E-01 --- EMANA(1)
R021 Emanating power of Rn-220 gas not used 1.500E-01 --- EMANA(2)
TITL Number of graphical time points 32 --- --- NPTS TITL Maximum number of integration points for dose 17 --- --- LYMAX TITL Maximum number of integration points for risk 1 --- --- KYMAX Summary of Pathway Selections Pathway User Selection 1 -- external gamma active 2 -- inhalation (w/o radon) active 3 -- plant ingestion active 4 -- meat ingestion active 5 -- milk ingestion active 6 -- aquatic foods active 7 -- drinking water active 8 -- soil ingestion active 9 -- radon suppressed Find peak pathway doses suppressed
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:31 Page 7 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Eu154-concrete-DCGL.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area: 5020.00 square meters Eu-154 1.000E+00 Thickness: 3.80 meters Cover Depth: 0.00 meters 0
Total Dose TDOSE(t), mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years): 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 TDOSE(t): 2.607E+00 2.410E+00 2.058E+00 1.185E+00 2.450E-01 9.837E-04 1.400E-10 0.000E+00 M(t): 1.043E-01 9.639E-02 8.234E-02 4.742E-02 9.801E-03 3.935E-05 5.600E-12 0.000E+00 0Maximum TDOSE(t): 2.607E+00 mrem/yr at t = 0.000E+00 years
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:31 Page 8 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Eu154-concrete-DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years 0 Water Independent Pathways (Inhalation excludes radon) 0 Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Eu-154 2.601E+00 0.9976 4.070E-06 0.0000 0.000E+00 0.0000 2.317E-04 0.0001 6.042E-04 0.0002 6.579E-05 0.0000 1.300E-04 0.0000 Total 2.601E+00 0.9976 4.070E-06 0.0000 0.000E+00 0.0000 2.317E-04 0.0001 6.042E-04 0.0002 6.579E-05 0.0000 1.300E-04 0.0000 0
Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years 0 Water Dependent Pathways 0 Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Eu-154 4.157E-03 0.0016 1.073E-04 0.0000 0.000E+00 0.0000 7.405E-04 0.0003 1.203E-04 0.0000 2.415E-05 0.0000 2.607E+00 1.0000 Total 4.157E-03 0.0016 1.073E-04 0.0000 0.000E+00 0.0000 7.405E-04 0.0003 1.203E-04 0.0000 2.415E-05 0.0000 2.607E+00 1.0000 0*Sum of all water independent and dependent pathways.
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:35 Page 1 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Eu155-concrete-DCGL.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary ... 2 Site-Specific Parameter Summary .......................... 3 Summary of Pathway Selections ............................ 6 Contaminated Zone and Total Dose Summary ................. 7 Total Dose Components Time = 0.000E+00 .................................... 8 Time = 1.000E+00 .................................... 9 Time = 3.000E+00 .................................... 10 Time = 1.000E+01 .................................... 11 Time = 3.000E+01 .................................... 12 Time = 1.000E+02 .................................... 13 Time = 3.000E+02 .................................... 14 Time = 1.000E+03 .................................... 15 Dose/Source Ratios Summed Over All Pathways .............. 16 Single Radionuclide Soil Guidelines ...................... 16 Dose Per Nuclide Summed Over All Pathways ................ 17 Soil Concentration Per Nuclide ........................... 17
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:35 Page 2 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Eu155-concrete-DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary File: YR Concrete 0 Current Parameter Menu Parameter Value Default Name B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 Eu-155 4.140E-05 4.140E-05 DCF2( 1)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Eu-155 1.530E-06 1.530E-06 DCF3( 1)
D-34 Food transfer factors:
D-34 Eu-155 , plant/soil concentration ratio, dimensionless 1.870E-04 2.500E-03 RTF( 1,1)
D-34 Eu-155 , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 2.000E-03 2.000E-03 RTF( 1,2)
D-34 Eu-155 , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 6.000E-05 2.000E-05 RTF( 1,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Eu-155 , fish 4.900E+01 5.000E+01 BIOFAC( 1,1)
D-5 Eu-155 , crustacea and mollusks 1.000E+03 1.000E+03 BIOFAC( 1,2)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:35 Page 3 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Eu155-concrete-DCGL.RAD Site-Specific Parameter Summary 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R011 Area of contaminated zone (m**2) 5.020E+03 1.000E+04 --- AREA R011 Thickness of contaminated zone (m) 3.800E+00 2.000E+00 --- THICK0 R011 Length parallel to aquifer flow (m) 8.000E+01 1.000E+02 --- LCZPAQ R011 Basic radiation dose limit (mrem/yr) 2.500E+01 2.500E+01 --- BRDL R011 Time since placement of material (yr) 0.000E+00 0.000E+00 --- TI R011 Times for calculations (yr) 1.000E+00 1.000E+00 --- T( 2)
R011 Times for calculations (yr) 3.000E+00 3.000E+00 --- T( 3)
R011 Times for calculations (yr) 1.000E+01 1.000E+01 --- T( 4)
R011 Times for calculations (yr) 3.000E+01 3.000E+01 --- T( 5)
R011 Times for calculations (yr) 1.000E+02 1.000E+02 --- T( 6)
R011 Times for calculations (yr) 3.000E+02 3.000E+02 --- T( 7)
R011 Times for calculations (yr) 1.000E+03 1.000E+03 --- T( 8)
R011 Times for calculations (yr) not used 0.000E+00 --- T( 9)
R011 Times for calculations (yr) not used 0.000E+00 --- T(10)
R012 Initial principal radionuclide (pCi/g): Eu-155 1.000E+00 0.000E+00 --- S1( 1)
R012 Concentration in groundwater (pCi/L): Eu-155 not used 0.000E+00 --- W1( 1)
R013 Cover depth (m) 0.000E+00 0.000E+00 --- COVER0 R013 Density of cover material (g/cm**3) not used 1.500E+00 --- DENSCV R013 Cover depth erosion rate (m/yr) not used 1.000E-03 --- VCV R013 Density of contaminated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSCZ R013 Contaminated zone erosion rate (m/yr) 8.500E-04 1.000E-03 --- VCZ R013 Contaminated zone total porosity 3.000E-01 4.000E-01 --- TPCZ R013 Contaminated zone field capacity 7.000E-02 2.000E-01 --- FCCZ R013 Contaminated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+01 --- HCCZ R013 Contaminated zone b parameter 9.750E-01 5.300E+00 --- BCZ R013 Average annual wind speed (m/sec) 2.030E+00 2.000E+00 --- WIND R013 Humidity in air (g/m**3) not used 8.000E+00 --- HUMID R013 Evapotranspiration coefficient 6.250E-01 5.000E-01 --- EVAPTR R013 Precipitation (m/yr) 1.200E+00 1.000E+00 --- PRECIP R013 Irrigation (m/yr) 4.350E-01 2.000E-01 --- RI R013 Irrigation mode overhead overhead --- IDITCH R013 Runoff coefficient 6.000E-01 2.000E-01 --- RUNOFF R013 Watershed area for nearby stream or pond (m**2) 7.770E+05 1.000E+06 --- WAREA R013 Accuracy for water/soil computations 1.000E-03 1.000E-03 --- EPS R014 Density of saturated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSAQ R014 Saturated zone total porosity 2.800E-01 4.000E-01 --- TPSZ R014 Saturated zone effective porosity 2.100E-01 2.000E-01 --- EPSZ R014 Saturated zone field capacity 7.000E-02 2.000E-01 --- FCSZ R014 Saturated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+02 --- HCSZ R014 Saturated zone hydraulic gradient 1.000E-01 2.000E-02 --- HGWT R014 Saturated zone b parameter 9.750E-01 5.300E+00 --- BSZ R014 Water table drop rate (m/yr) 1.000E-03 1.000E-03 --- VWT R014 Well pump intake depth (m below water table) 1.000E+01 1.000E+01 --- DWIBWT R014 Model: Nondispersion (ND) or Mass-Balance (MB) MB ND --- MODEL R014 Well pumping rate (m**3/yr) 2.500E+02 2.500E+02 --- UW R015 Number of unsaturated zone strata 0 1 --- NS
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:35 Page 4 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Eu155-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R016 Distribution coefficients for Eu-155 R016 Contaminated zone (cm**3/g) 1.000E+03 -1.000E+00 --- DCNUCC( 1)
R016 Saturated zone (cm**3/g) 0.000E+00 -1.000E+00 --- DCNUCS( 1)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 5.863E-05 ALEACH( 1)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 1)
R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 --- INHALR R017 Mass loading for inhalation (g/m**3) 2.330E-05 1.000E-04 --- MLINH R017 Exposure duration 3.000E+01 3.000E+01 --- ED R017 Shielding factor, inhalation 5.500E-01 4.000E-01 --- SHF3 R017 Shielding factor, external gamma 3.980E-01 7.000E-01 --- SHF1 R017 Fraction of time spent indoors 6.571E-01 5.000E-01 --- FIND R017 Fraction of time spent outdoors (on site) 1.181E-01 2.500E-01 --- FOTD R017 Shape factor flag, external gamma 1.000E+00 1.000E+00 >0 shows circular AREA. FS R017 Radii of shape factor array (used if FS = -1):
R017 Outer annular radius (m), ring 1: not used 5.000E+01 --- RAD_SHAPE( 1)
R017 Outer annular radius (m), ring 2: not used 7.071E+01 --- RAD_SHAPE( 2)
R017 Outer annular radius (m), ring 3: not used 0.000E+00 --- RAD_SHAPE( 3)
R017 Outer annular radius (m), ring 4: not used 0.000E+00 --- RAD_SHAPE( 4)
R017 Outer annular radius (m), ring 5: not used 0.000E+00 --- RAD_SHAPE( 5)
R017 Outer annular radius (m), ring 6: not used 0.000E+00 --- RAD_SHAPE( 6)
R017 Outer annular radius (m), ring 7: not used 0.000E+00 --- RAD_SHAPE( 7)
R017 Outer annular radius (m), ring 8: not used 0.000E+00 --- RAD_SHAPE( 8)
R017 Outer annular radius (m), ring 9: not used 0.000E+00 --- RAD_SHAPE( 9)
R017 Outer annular radius (m), ring 10: not used 0.000E+00 --- RAD_SHAPE(10)
R017 Outer annular radius (m), ring 11: not used 0.000E+00 --- RAD_SHAPE(11)
R017 Outer annular radius (m), ring 12: not used 0.000E+00 --- RAD_SHAPE(12)
R017 Fractions of annular areas within AREA:
R017 Ring 1 not used 1.000E+00 --- FRACA( 1)
R017 Ring 2 not used 2.732E-01 --- FRACA( 2)
R017 Ring 3 not used 0.000E+00 --- FRACA( 3)
R017 Ring 4 not used 0.000E+00 --- FRACA( 4)
R017 Ring 5 not used 0.000E+00 --- FRACA( 5)
R017 Ring 6 not used 0.000E+00 --- FRACA( 6)
R017 Ring 7 not used 0.000E+00 --- FRACA( 7)
R017 Ring 8 not used 0.000E+00 --- FRACA( 8)
R017 Ring 9 not used 0.000E+00 --- FRACA( 9)
R017 Ring 10 not used 0.000E+00 --- FRACA(10)
R017 Ring 11 not used 0.000E+00 --- FRACA(11)
R017 Ring 12 not used 0.000E+00 --- FRACA(12)
R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 --- DIET(1)
R018 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 --- DIET(2)
R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 --- DIET(3)
R018 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 --- DIET(4)
R018 Fish consumption (kg/yr) 2.060E+01 5.400E+00 --- DIET(5)
R018 Other seafood consumption (kg/yr) 9.000E-01 9.000E-01 --- DIET(6)
R018 Soil ingestion rate (g/yr) 1.826E+01 3.650E+01 --- SOIL R018 Drinking water intake (L/yr) 4.785E+02 5.100E+02 --- DWI
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:35 Page 5 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Eu155-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R018 Contamination fraction of drinking water 1.000E+00 1.000E+00 --- FDW R018 Contamination fraction of household water not used 1.000E+00 --- FHHW R018 Contamination fraction of livestock water 1.000E+00 1.000E+00 --- FLW R018 Contamination fraction of irrigation water 1.000E+00 1.000E+00 --- FIRW R018 Contamination fraction of aquatic food 1.000E+00 5.000E-01 --- FR9 R018 Contamination fraction of plant food 1.000E+00 -1 --- FPLANT R018 Contamination fraction of meat 1.000E+00 -1 --- FMEAT R018 Contamination fraction of milk 1.000E+00 -1 --- FMILK R019 Livestock fodder intake for meat (kg/day) 2.710E+01 6.800E+01 --- LFI5 R019 Livestock fodder intake for milk (kg/day) 6.320E+01 5.500E+01 --- LFI6 R019 Livestock water intake for meat (L/day) 5.060E+01 5.000E+01 --- LWI5 R019 Livestock water intake for milk (L/day) 6.000E+01 1.600E+02 --- LWI6 R019 Livestock soil intake (kg/day) 5.000E-01 5.000E-01 --- LSI R019 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.000E-04 --- MLFD R019 Depth of soil mixing layer (m) 2.300E-01 1.500E-01 --- DM R019 Depth of roots (m) 2.050E+00 9.000E-01 --- DROOT R019 Drinking water fraction from ground water 1.000E+00 1.000E+00 --- FGWDW R019 Household water fraction from ground water not used 1.000E+00 --- FGWHH R019 Livestock water fraction from ground water 1.000E+00 1.000E+00 --- FGWLW R019 Irrigation fraction from ground water 1.000E+00 1.000E+00 --- FGWIR R19B Wet weight crop yield for Non-Leafy (kg/m**2) 1.750E+00 7.000E-01 --- YV(1)
R19B Wet weight crop yield for Leafy (kg/m**2) 2.889E+00 1.500E+00 --- YV(2)
R19B Wet weight crop yield for Fodder (kg/m**2) 1.887E+00 1.100E+00 --- YV(3)
R19B Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 --- TE(1)
R19B Growing Season for Leafy (years) 1.230E-01 2.500E-01 --- TE(2)
R19B Growing Season for Fodder (years) 8.200E-02 8.000E-02 --- TE(3)
R19B Translocation Factor for Non-Leafy 1.000E-01 1.000E-01 --- TIV(1)
R19B Translocation Factor for Leafy 1.000E+00 1.000E+00 --- TIV(2)
R19B Translocation Factor for Fodder 1.000E+00 1.000E+00 --- TIV(3)
R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RDRY(1)
R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 --- RDRY(2)
R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RDRY(3)
R19B Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RWET(1)
R19B Wet Foliar Interception Fraction for Leafy 5.800E-01 2.500E-01 --- RWET(2)
R19B Wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RWET(3)
R19B Weathering Removal Constant for Vegetation 3.300E+01 2.000E+01 --- WLAM C14 C-12 concentration in water (g/cm**3) not used 2.000E-05 --- C12WTR C14 C-12 concentration in contaminated soil (g/g) not used 3.000E-02 --- C12CZ C14 Fraction of vegetation carbon from soil not used 2.000E-02 --- CSOIL C14 Fraction of vegetation carbon from air not used 9.800E-01 --- CAIR C14 C-14 evasion layer thickness in soil (m) not used 3.000E-01 --- DMC C14 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 --- EVSN C14 C-12 evasion flux rate from soil (1/sec) not used 1.000E-10 --- REVSN C14 Fraction of grain in beef cattle feed not used 8.000E-01 --- AVFG4 C14 Fraction of grain in milk cow feed not used 2.000E-01 --- AVFG5 C14 DCF correction factor for gaseous forms of C14 not used 8.894E+01 --- CO2F
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:35 Page 6 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Eu155-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 --- STOR_T(1)
STOR Leafy vegetables 1.000E+00 1.000E+00 --- STOR_T(2)
STOR Milk 1.000E+00 1.000E+00 --- STOR_T(3)
STOR Meat and poultry 2.000E+01 2.000E+01 --- STOR_T(4)
STOR Fish 7.000E+00 7.000E+00 --- STOR_T(5)
STOR Crustacea and mollusks 7.000E+00 7.000E+00 --- STOR_T(6)
STOR Well water 1.000E+00 1.000E+00 --- STOR_T(7)
STOR Surface water 1.000E+00 1.000E+00 --- STOR_T(8)
STOR Livestock fodder 4.500E+01 4.500E+01 --- STOR_T(9)
R021 Thickness of building foundation (m) not used 1.500E-01 --- FLOOR1 R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 --- DENSFL R021 Total porosity of the cover material not used 4.000E-01 --- TPCV R021 Total porosity of the building foundation not used 1.000E-01 --- TPFL R021 Volumetric water content of the cover material not used 5.000E-02 --- PH2OCV R021 Volumetric water content of the foundation not used 3.000E-02 --- PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.000E-06 --- DIFCV R021 in foundation material not used 3.000E-07 --- DIFFL R021 in contaminated zone soil not used 2.000E-06 --- DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.000E+00 --- HMIX R021 Average building air exchange rate (1/hr) not used 5.000E-01 --- REXG R021 Height of the building (room) (m) not used 2.500E+00 --- HRM R021 Building interior area factor not used 0.000E+00 --- FAI R021 Building depth below ground surface (m) not used -1.000E+00 --- DMFL R021 Emanating power of Rn-222 gas not used 2.500E-01 --- EMANA(1)
R021 Emanating power of Rn-220 gas not used 1.500E-01 --- EMANA(2)
TITL Number of graphical time points 32 --- --- NPTS TITL Maximum number of integration points for dose 17 --- --- LYMAX TITL Maximum number of integration points for risk 1 --- --- KYMAX Summary of Pathway Selections Pathway User Selection 1 -- external gamma active 2 -- inhalation (w/o radon) active 3 -- plant ingestion active 4 -- meat ingestion active 5 -- milk ingestion active 6 -- aquatic foods active 7 -- drinking water active 8 -- soil ingestion active 9 -- radon suppressed Find peak pathway doses suppressed
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:35 Page 7 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Eu155-concrete-DCGL.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area: 5020.00 square meters Eu-155 1.000E+00 Thickness: 3.80 meters Cover Depth: 0.00 meters 0
Total Dose TDOSE(t), mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years): 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 TDOSE(t): 6.229E-02 5.420E-02 4.098E-02 1.540E-02 9.401E-04 5.283E-08 3.795E-20 0.000E+00 M(t): 2.491E-03 2.168E-03 1.639E-03 6.160E-04 3.760E-05 2.113E-09 1.518E-21 0.000E+00 0Maximum TDOSE(t): 6.229E-02 mrem/yr at t = 0.000E+00 years
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:35 Page 8 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Eu155-concrete-DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years 0 Water Independent Pathways (Inhalation excludes radon) 0 Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Eu-155 6.132E-02 0.9846 5.718E-07 0.0000 0.000E+00 0.0000 3.603E-05 0.0006 9.395E-05 0.0015 1.023E-05 0.0002 2.021E-05 0.0003 Total 6.132E-02 0.9846 5.718E-07 0.0000 0.000E+00 0.0000 3.603E-05 0.0006 9.395E-05 0.0015 1.023E-05 0.0002 2.021E-05 0.0003 0
Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years 0 Water Dependent Pathways 0 Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Eu-155 6.453E-04 0.0104 1.666E-05 0.0003 0.000E+00 0.0000 1.150E-04 0.0018 1.866E-05 0.0003 3.747E-06 0.0001 6.229E-02 1.0000 Total 6.453E-04 0.0104 1.666E-05 0.0003 0.000E+00 0.0000 1.150E-04 0.0018 1.866E-05 0.0003 3.747E-06 0.0001 6.229E-02 1.0000 0*Sum of all water independent and dependent pathways.
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:41 Page 1 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Fe55-concrete-DCGL.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary ... 2 Site-Specific Parameter Summary .......................... 3 Summary of Pathway Selections ............................ 6 Contaminated Zone and Total Dose Summary ................. 7 Total Dose Components Time = 0.000E+00 .................................... 8 Time = 1.000E+00 .................................... 9 Time = 3.000E+00 .................................... 10 Time = 1.000E+01 .................................... 11 Time = 3.000E+01 .................................... 12 Time = 1.000E+02 .................................... 13 Time = 3.000E+02 .................................... 14 Time = 1.000E+03 .................................... 15 Dose/Source Ratios Summed Over All Pathways .............. 16 Single Radionuclide Soil Guidelines ...................... 16 Dose Per Nuclide Summed Over All Pathways ................ 17 Soil Concentration Per Nuclide ........................... 17
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:41 Page 2 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Fe55-concrete-DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary File: YR Concrete 0 Current Parameter Menu Parameter Value Default Name B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 Fe-55 2.690E-06 2.690E-06 DCF2( 1)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Fe-55 6.070E-07 6.070E-07 DCF3( 1)
D-34 Food transfer factors:
D-34 Fe-55 , plant/soil concentration ratio, dimensionless 1.050E+00 1.000E-03 RTF( 1,1)
D-34 Fe-55 , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 3.910E-02 2.000E-02 RTF( 1,2)
D-34 Fe-55 , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 4.810E-04 3.000E-04 RTF( 1,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Fe-55 , fish 4.200E+02 2.000E+02 BIOFAC( 1,1)
D-5 Fe-55 , crustacea and mollusks 3.200E+03 3.200E+03 BIOFAC( 1,2)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:41 Page 3 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Fe55-concrete-DCGL.RAD Site-Specific Parameter Summary 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R011 Area of contaminated zone (m**2) 5.020E+03 1.000E+04 --- AREA R011 Thickness of contaminated zone (m) 3.800E+00 2.000E+00 --- THICK0 R011 Length parallel to aquifer flow (m) 8.000E+01 1.000E+02 --- LCZPAQ R011 Basic radiation dose limit (mrem/yr) 2.500E+01 2.500E+01 --- BRDL R011 Time since placement of material (yr) 0.000E+00 0.000E+00 --- TI R011 Times for calculations (yr) 1.000E+00 1.000E+00 --- T( 2)
R011 Times for calculations (yr) 3.000E+00 3.000E+00 --- T( 3)
R011 Times for calculations (yr) 1.000E+01 1.000E+01 --- T( 4)
R011 Times for calculations (yr) 3.000E+01 3.000E+01 --- T( 5)
R011 Times for calculations (yr) 1.000E+02 1.000E+02 --- T( 6)
R011 Times for calculations (yr) 3.000E+02 3.000E+02 --- T( 7)
R011 Times for calculations (yr) 1.000E+03 1.000E+03 --- T( 8)
R011 Times for calculations (yr) not used 0.000E+00 --- T( 9)
R011 Times for calculations (yr) not used 0.000E+00 --- T(10)
R012 Initial principal radionuclide (pCi/g): Fe-55 1.000E+00 0.000E+00 --- S1( 1)
R012 Concentration in groundwater (pCi/L): Fe-55 not used 0.000E+00 --- W1( 1)
R013 Cover depth (m) 0.000E+00 0.000E+00 --- COVER0 R013 Density of cover material (g/cm**3) not used 1.500E+00 --- DENSCV R013 Cover depth erosion rate (m/yr) not used 1.000E-03 --- VCV R013 Density of contaminated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSCZ R013 Contaminated zone erosion rate (m/yr) 8.500E-04 1.000E-03 --- VCZ R013 Contaminated zone total porosity 3.000E-01 4.000E-01 --- TPCZ R013 Contaminated zone field capacity 7.000E-02 2.000E-01 --- FCCZ R013 Contaminated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+01 --- HCCZ R013 Contaminated zone b parameter 9.750E-01 5.300E+00 --- BCZ R013 Average annual wind speed (m/sec) 2.030E+00 2.000E+00 --- WIND R013 Humidity in air (g/m**3) not used 8.000E+00 --- HUMID R013 Evapotranspiration coefficient 6.250E-01 5.000E-01 --- EVAPTR R013 Precipitation (m/yr) 1.200E+00 1.000E+00 --- PRECIP R013 Irrigation (m/yr) 4.350E-01 2.000E-01 --- RI R013 Irrigation mode overhead overhead --- IDITCH R013 Runoff coefficient 6.000E-01 2.000E-01 --- RUNOFF R013 Watershed area for nearby stream or pond (m**2) 7.770E+05 1.000E+06 --- WAREA R013 Accuracy for water/soil computations 1.000E-03 1.000E-03 --- EPS R014 Density of saturated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSAQ R014 Saturated zone total porosity 2.800E-01 4.000E-01 --- TPSZ R014 Saturated zone effective porosity 2.100E-01 2.000E-01 --- EPSZ R014 Saturated zone field capacity 7.000E-02 2.000E-01 --- FCSZ R014 Saturated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+02 --- HCSZ R014 Saturated zone hydraulic gradient 1.000E-01 2.000E-02 --- HGWT R014 Saturated zone b parameter 9.750E-01 5.300E+00 --- BSZ R014 Water table drop rate (m/yr) 1.000E-03 1.000E-03 --- VWT R014 Well pump intake depth (m below water table) 1.000E+01 1.000E+01 --- DWIBWT R014 Model: Nondispersion (ND) or Mass-Balance (MB) MB ND --- MODEL R014 Well pumping rate (m**3/yr) 2.500E+02 2.500E+02 --- UW R015 Number of unsaturated zone strata 0 1 --- NS
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:41 Page 4 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Fe55-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R016 Distribution coefficients for Fe-55 R016 Contaminated zone (cm**3/g) 1.250E+01 1.000E+03 --- DCNUCC( 1)
R016 Saturated zone (cm**3/g) 0.000E+00 1.000E+03 --- DCNUCS( 1)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 4.674E-03 ALEACH( 1)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 1)
R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 --- INHALR R017 Mass loading for inhalation (g/m**3) 2.330E-05 1.000E-04 --- MLINH R017 Exposure duration 3.000E+01 3.000E+01 --- ED R017 Shielding factor, inhalation 5.500E-01 4.000E-01 --- SHF3 R017 Shielding factor, external gamma 2.725E-01 7.000E-01 --- SHF1 R017 Fraction of time spent indoors 6.571E-01 5.000E-01 --- FIND R017 Fraction of time spent outdoors (on site) 1.181E-01 2.500E-01 --- FOTD R017 Shape factor flag, external gamma 1.000E+00 1.000E+00 >0 shows circular AREA. FS R017 Radii of shape factor array (used if FS = -1):
R017 Outer annular radius (m), ring 1: not used 5.000E+01 --- RAD_SHAPE( 1)
R017 Outer annular radius (m), ring 2: not used 7.071E+01 --- RAD_SHAPE( 2)
R017 Outer annular radius (m), ring 3: not used 0.000E+00 --- RAD_SHAPE( 3)
R017 Outer annular radius (m), ring 4: not used 0.000E+00 --- RAD_SHAPE( 4)
R017 Outer annular radius (m), ring 5: not used 0.000E+00 --- RAD_SHAPE( 5)
R017 Outer annular radius (m), ring 6: not used 0.000E+00 --- RAD_SHAPE( 6)
R017 Outer annular radius (m), ring 7: not used 0.000E+00 --- RAD_SHAPE( 7)
R017 Outer annular radius (m), ring 8: not used 0.000E+00 --- RAD_SHAPE( 8)
R017 Outer annular radius (m), ring 9: not used 0.000E+00 --- RAD_SHAPE( 9)
R017 Outer annular radius (m), ring 10: not used 0.000E+00 --- RAD_SHAPE(10)
R017 Outer annular radius (m), ring 11: not used 0.000E+00 --- RAD_SHAPE(11)
R017 Outer annular radius (m), ring 12: not used 0.000E+00 --- RAD_SHAPE(12)
R017 Fractions of annular areas within AREA:
R017 Ring 1 not used 1.000E+00 --- FRACA( 1)
R017 Ring 2 not used 2.732E-01 --- FRACA( 2)
R017 Ring 3 not used 0.000E+00 --- FRACA( 3)
R017 Ring 4 not used 0.000E+00 --- FRACA( 4)
R017 Ring 5 not used 0.000E+00 --- FRACA( 5)
R017 Ring 6 not used 0.000E+00 --- FRACA( 6)
R017 Ring 7 not used 0.000E+00 --- FRACA( 7)
R017 Ring 8 not used 0.000E+00 --- FRACA( 8)
R017 Ring 9 not used 0.000E+00 --- FRACA( 9)
R017 Ring 10 not used 0.000E+00 --- FRACA(10)
R017 Ring 11 not used 0.000E+00 --- FRACA(11)
R017 Ring 12 not used 0.000E+00 --- FRACA(12)
R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 --- DIET(1)
R018 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 --- DIET(2)
R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 --- DIET(3)
R018 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 --- DIET(4)
R018 Fish consumption (kg/yr) 2.060E+01 5.400E+00 --- DIET(5)
R018 Other seafood consumption (kg/yr) 9.000E-01 9.000E-01 --- DIET(6)
R018 Soil ingestion rate (g/yr) 1.826E+01 3.650E+01 --- SOIL R018 Drinking water intake (L/yr) 4.785E+02 5.100E+02 --- DWI
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:41 Page 5 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Fe55-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R018 Contamination fraction of drinking water 1.000E+00 1.000E+00 --- FDW R018 Contamination fraction of household water not used 1.000E+00 --- FHHW R018 Contamination fraction of livestock water 1.000E+00 1.000E+00 --- FLW R018 Contamination fraction of irrigation water 1.000E+00 1.000E+00 --- FIRW R018 Contamination fraction of aquatic food 1.000E+00 5.000E-01 --- FR9 R018 Contamination fraction of plant food 1.000E+00 -1 --- FPLANT R018 Contamination fraction of meat 1.000E+00 -1 --- FMEAT R018 Contamination fraction of milk 1.000E+00 -1 --- FMILK R019 Livestock fodder intake for meat (kg/day) 2.710E+01 6.800E+01 --- LFI5 R019 Livestock fodder intake for milk (kg/day) 6.320E+01 5.500E+01 --- LFI6 R019 Livestock water intake for meat (L/day) 5.060E+01 5.000E+01 --- LWI5 R019 Livestock water intake for milk (L/day) 6.000E+01 1.600E+02 --- LWI6 R019 Livestock soil intake (kg/day) 5.000E-01 5.000E-01 --- LSI R019 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.000E-04 --- MLFD R019 Depth of soil mixing layer (m) 2.300E-01 1.500E-01 --- DM R019 Depth of roots (m) 2.050E+00 9.000E-01 --- DROOT R019 Drinking water fraction from ground water 1.000E+00 1.000E+00 --- FGWDW R019 Household water fraction from ground water not used 1.000E+00 --- FGWHH R019 Livestock water fraction from ground water 1.000E+00 1.000E+00 --- FGWLW R019 Irrigation fraction from ground water 1.000E+00 1.000E+00 --- FGWIR R19B Wet weight crop yield for Non-Leafy (kg/m**2) 1.750E+00 7.000E-01 --- YV(1)
R19B Wet weight crop yield for Leafy (kg/m**2) 2.889E+00 1.500E+00 --- YV(2)
R19B Wet weight crop yield for Fodder (kg/m**2) 1.887E+00 1.100E+00 --- YV(3)
R19B Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 --- TE(1)
R19B Growing Season for Leafy (years) 1.230E-01 2.500E-01 --- TE(2)
R19B Growing Season for Fodder (years) 8.200E-02 8.000E-02 --- TE(3)
R19B Translocation Factor for Non-Leafy 1.000E-01 1.000E-01 --- TIV(1)
R19B Translocation Factor for Leafy 1.000E+00 1.000E+00 --- TIV(2)
R19B Translocation Factor for Fodder 1.000E+00 1.000E+00 --- TIV(3)
R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RDRY(1)
R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 --- RDRY(2)
R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RDRY(3)
R19B Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RWET(1)
R19B Wet Foliar Interception Fraction for Leafy 5.800E-01 2.500E-01 --- RWET(2)
R19B Wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RWET(3)
R19B Weathering Removal Constant for Vegetation 2.150E+01 2.000E+01 --- WLAM C14 C-12 concentration in water (g/cm**3) not used 2.000E-05 --- C12WTR C14 C-12 concentration in contaminated soil (g/g) not used 3.000E-02 --- C12CZ C14 Fraction of vegetation carbon from soil not used 2.000E-02 --- CSOIL C14 Fraction of vegetation carbon from air not used 9.800E-01 --- CAIR C14 C-14 evasion layer thickness in soil (m) not used 3.000E-01 --- DMC C14 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 --- EVSN C14 C-12 evasion flux rate from soil (1/sec) not used 1.000E-10 --- REVSN C14 Fraction of grain in beef cattle feed not used 8.000E-01 --- AVFG4 C14 Fraction of grain in milk cow feed not used 2.000E-01 --- AVFG5 C14 DCF correction factor for gaseous forms of C14 not used 8.894E+01 --- CO2F
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:41 Page 6 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Fe55-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 --- STOR_T(1)
STOR Leafy vegetables 1.000E+00 1.000E+00 --- STOR_T(2)
STOR Milk 1.000E+00 1.000E+00 --- STOR_T(3)
STOR Meat and poultry 2.000E+01 2.000E+01 --- STOR_T(4)
STOR Fish 7.000E+00 7.000E+00 --- STOR_T(5)
STOR Crustacea and mollusks 7.000E+00 7.000E+00 --- STOR_T(6)
STOR Well water 1.000E+00 1.000E+00 --- STOR_T(7)
STOR Surface water 1.000E+00 1.000E+00 --- STOR_T(8)
STOR Livestock fodder 4.500E+01 4.500E+01 --- STOR_T(9)
R021 Thickness of building foundation (m) not used 1.500E-01 --- FLOOR1 R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 --- DENSFL R021 Total porosity of the cover material not used 4.000E-01 --- TPCV R021 Total porosity of the building foundation not used 1.000E-01 --- TPFL R021 Volumetric water content of the cover material not used 5.000E-02 --- PH2OCV R021 Volumetric water content of the foundation not used 3.000E-02 --- PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.000E-06 --- DIFCV R021 in foundation material not used 3.000E-07 --- DIFFL R021 in contaminated zone soil not used 2.000E-06 --- DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.000E+00 --- HMIX R021 Average building air exchange rate (1/hr) not used 5.000E-01 --- REXG R021 Height of the building (room) (m) not used 2.500E+00 --- HRM R021 Building interior area factor not used 0.000E+00 --- FAI R021 Building depth below ground surface (m) not used -1.000E+00 --- DMFL R021 Emanating power of Rn-222 gas not used 2.500E-01 --- EMANA(1)
R021 Emanating power of Rn-220 gas not used 1.500E-01 --- EMANA(2)
TITL Number of graphical time points 32 --- --- NPTS TITL Maximum number of integration points for dose 17 --- --- LYMAX TITL Maximum number of integration points for risk 1 --- --- KYMAX Summary of Pathway Selections Pathway User Selection 1 -- external gamma active 2 -- inhalation (w/o radon) active 3 -- plant ingestion active 4 -- meat ingestion active 5 -- milk ingestion active 6 -- aquatic foods active 7 -- drinking water active 8 -- soil ingestion active 9 -- radon suppressed Find peak pathway doses suppressed
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:41 Page 7 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Fe55-concrete-DCGL.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area: 5020.00 square meters Fe-55 1.000E+00 Thickness: 3.80 meters Cover Depth: 0.00 meters 0
Total Dose TDOSE(t), mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years): 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 TDOSE(t): 1.613E-01 1.270E-01 7.531E-02 1.208E-02 6.471E-05 7.286E-13 0.000E+00 0.000E+00 M(t): 6.452E-03 5.081E-03 3.012E-03 4.831E-04 2.588E-06 2.914E-14 0.000E+00 0.000E+00 0Maximum TDOSE(t): 1.613E-01 mrem/yr at t = 0.000E+00 years
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:41 Page 8 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Fe55-concrete-DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years 0 Water Independent Pathways (Inhalation excludes radon) 0 Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Fe-55 0.000E+00 0.0000 3.503E-08 0.0000 0.000E+00 0.0000 7.483E-02 0.4639 3.940E-02 0.2442 4.005E-03 0.0248 7.561E-06 0.0000 Total 0.000E+00 0.0000 3.503E-08 0.0000 0.000E+00 0.0000 7.483E-02 0.4639 3.940E-02 0.2442 4.005E-03 0.0248 7.561E-06 0.0000 0
Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years 0 Water Dependent Pathways 0 Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Fe-55 1.919E-02 0.1189 2.991E-03 0.0185 0.000E+00 0.0000 6.599E-03 0.0409 1.314E-02 0.0815 1.148E-03 0.0071 1.613E-01 1.0000 Total 1.919E-02 0.1189 2.991E-03 0.0185 0.000E+00 0.0000 6.599E-03 0.0409 1.314E-02 0.0815 1.148E-03 0.0071 1.613E-01 1.0000 0*Sum of all water independent and dependent pathways.
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/18/2004 20:27 Page 1 Summary : Yankee Rowe DCGL=concrete grading File : H-3_graded concrete-dcgl.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary ... 2 Site-Specific Parameter Summary .......................... 3 Summary of Pathway Selections ............................ 7 Contaminated Zone and Total Dose Summary ................. 8 Total Dose Components Time = 0.000E+00 .................................... 9 Time = 1.000E+00 .................................... 10 Time = 3.000E+00 .................................... 11 Time = 1.000E+01 .................................... 12 Time = 3.000E+01 .................................... 13 Time = 1.000E+02 .................................... 14 Time = 3.000E+02 .................................... 15 Time = 1.000E+03 .................................... 16 Dose/Source Ratios Summed Over All Pathways .............. 17 Single Radionuclide Soil Guidelines ...................... 17 Dose Per Nuclide Summed Over All Pathways ................ 18 Soil Concentration Per Nuclide ........................... 18
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/18/2004 20:27 Page 2 Summary : Yankee Rowe DCGL=concrete grading File : H-3_graded concrete-dcgl.RAD Dose Conversion Factor (and Related) Parameter Summary File: FGR 13 Morbidity 0 Current Parameter Menu Parameter Value Default Name B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 H-3 6.400E-08 6.400E-08 DCF2( 1)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 H-3 6.400E-08 6.400E-08 DCF3( 1)
D-34 Food transfer factors:
D-34 H-3 , plant/soil concentration ratio, dimensionless 4.800E+00 4.800E+00 RTF( 1,1)
D-34 H-3 , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.200E-02 1.200E-02 RTF( 1,2)
D-34 H-3 , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.000E-02 1.000E-02 RTF( 1,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 H-3 , fish 1.000E+00 1.000E+00 BIOFAC( 1,1)
D-5 H-3 , crustacea and mollusks 1.000E+00 1.000E+00 BIOFAC( 1,2)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/18/2004 20:27 Page 3 Summary : Yankee Rowe DCGL=concrete grading File : H-3_graded concrete-dcgl.RAD Site-Specific Parameter Summary 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R011 Area of contaminated zone (m**2) 5.020E+03 1.000E+04 --- AREA R011 Thickness of contaminated zone (m) 2.887E+00 2.000E+00 --- THICK0 R011 Length parallel to aquifer flow (m) 8.000E+01 1.000E+02 --- LCZPAQ R011 Basic radiation dose limit (mrem/yr) 2.500E+01 2.500E+01 --- BRDL R011 Time since placement of material (yr) 0.000E+00 0.000E+00 --- TI R011 Times for calculations (yr) 1.000E+00 1.000E+00 --- T( 2)
R011 Times for calculations (yr) 3.000E+00 3.000E+00 --- T( 3)
R011 Times for calculations (yr) 1.000E+01 1.000E+01 --- T( 4)
R011 Times for calculations (yr) 3.000E+01 3.000E+01 --- T( 5)
R011 Times for calculations (yr) 1.000E+02 1.000E+02 --- T( 6)
R011 Times for calculations (yr) 3.000E+02 3.000E+02 --- T( 7)
R011 Times for calculations (yr) 1.000E+03 1.000E+03 --- T( 8)
R011 Times for calculations (yr) not used 0.000E+00 --- T( 9)
R011 Times for calculations (yr) not used 0.000E+00 --- T(10)
R012 Initial principal radionuclide (pCi/g): H-3 1.000E+00 0.000E+00 --- S1( 1)
R012 Concentration in groundwater (pCi/L): H-3 not used 0.000E+00 --- W1( 1)
R013 Cover depth (m) 0.000E+00 0.000E+00 --- COVER0 R013 Density of cover material (g/cm**3) not used 1.500E+00 --- DENSCV R013 Cover depth erosion rate (m/yr) not used 1.000E-03 --- VCV R013 Density of contaminated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSCZ R013 Contaminated zone erosion rate (m/yr) 8.500E-04 1.000E-03 --- VCZ R013 Contaminated zone total porosity 3.000E-01 4.000E-01 --- TPCZ R013 Contaminated zone field capacity 7.000E-02 2.000E-01 --- FCCZ R013 Contaminated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+01 --- HCCZ R013 Contaminated zone b parameter 9.750E-01 5.300E+00 --- BCZ R013 Average annual wind speed (m/sec) 2.030E+00 2.000E+00 --- WIND R013 Humidity in air (g/m**3) 6.100E+00 8.000E+00 --- HUMID R013 Evapotranspiration coefficient 6.250E-01 5.000E-01 --- EVAPTR R013 Precipitation (m/yr) 1.200E+00 1.000E+00 --- PRECIP R013 Irrigation (m/yr) 4.350E-01 2.000E-01 --- RI R013 Irrigation mode overhead overhead --- IDITCH R013 Runoff coefficient 6.000E-01 2.000E-01 --- RUNOFF R013 Watershed area for nearby stream or pond (m**2) 7.770E+05 1.000E+06 --- WAREA R013 Accuracy for water/soil computations 1.000E-03 1.000E-03 --- EPS R014 Density of saturated zone (g/cm**3) 1.510E+00 1.500E+00 --- DENSAQ R014 Saturated zone total porosity 4.300E-01 4.000E-01 --- TPSZ R014 Saturated zone effective porosity 3.830E-01 2.000E-01 --- EPSZ R014 Saturated zone field capacity 5.000E-02 2.000E-01 --- FCSZ R014 Saturated zone hydraulic conductivity (m/yr) 2.506E+03 1.000E+02 --- HCSZ R014 Saturated zone hydraulic gradient 1.000E-01 2.000E-02 --- HGWT R014 Saturated zone b parameter 9.750E-01 5.300E+00 --- BSZ R014 Water table drop rate (m/yr) 1.000E-03 1.000E-03 --- VWT R014 Well pump intake depth (m below water table) 1.451E+01 1.000E+01 --- DWIBWT R014 Model: Nondispersion (ND) or Mass-Balance (MB) ND ND --- MODEL R014 Well pumping rate (m**3/yr) 1.323E+03 2.500E+02 --- UW R015 Number of unsaturated zone strata 1 1 --- NS
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/18/2004 20:27 Page 4 Summary : Yankee Rowe DCGL=concrete grading File : H-3_graded concrete-dcgl.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R015 Unsat. zone 1, thickness (m) 1.820E+00 4.000E+00 --- H(1)
R015 Unsat. zone 1, soil density (g/cm**3) 1.510E+00 1.500E+00 --- DENSUZ(1)
R015 Unsat. zone 1, total porosity 4.300E-01 4.000E-01 --- TPUZ(1)
R015 Unsat. zone 1, effective porosity 3.830E-01 2.000E-01 --- EPUZ(1)
R015 Unsat. zone 1, field capacity 5.000E-02 2.000E-01 --- FCUZ(1)
R015 Unsat. zone 1, soil-specific b parameter 9.750E-01 5.300E+00 --- BUZ(1)
R015 Unsat. zone 1, hydraulic conductivity (m/yr) 2.506E+03 1.000E+01 --- HCUZ(1)
R016 Distribution coefficients for H-3 R016 Contaminated zone (cm**3/g) 0.000E+00 0.000E+00 --- DCNUCC( 1)
R016 Unsaturated zone 1 (cm**3/g) 6.000E-02 0.000E+00 --- DCNUCU( 1,1)
R016 Saturated zone (cm**3/g) 6.000E-02 0.000E+00 --- DCNUCS( 1)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 1.698E+00 ALEACH( 1)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 1)
R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 --- INHALR R017 Mass loading for inhalation (g/m**3) 2.330E-05 1.000E-04 --- MLINH R017 Exposure duration 3.000E+01 3.000E+01 --- ED R017 Shielding factor, inhalation 5.500E-01 4.000E-01 --- SHF3 R017 Shielding factor, external gamma 2.725E-01 7.000E-01 --- SHF1 R017 Fraction of time spent indoors 6.571E-01 5.000E-01 --- FIND R017 Fraction of time spent outdoors (on site) 1.181E-01 2.500E-01 --- FOTD R017 Shape factor flag, external gamma 1.000E+00 1.000E+00 >0 shows circular AREA. FS R017 Radii of shape factor array (used if FS = -1):
R017 Outer annular radius (m), ring 1: not used 5.000E+01 --- RAD_SHAPE( 1)
R017 Outer annular radius (m), ring 2: not used 7.071E+01 --- RAD_SHAPE( 2)
R017 Outer annular radius (m), ring 3: not used 0.000E+00 --- RAD_SHAPE( 3)
R017 Outer annular radius (m), ring 4: not used 0.000E+00 --- RAD_SHAPE( 4)
R017 Outer annular radius (m), ring 5: not used 0.000E+00 --- RAD_SHAPE( 5)
R017 Outer annular radius (m), ring 6: not used 0.000E+00 --- RAD_SHAPE( 6)
R017 Outer annular radius (m), ring 7: not used 0.000E+00 --- RAD_SHAPE( 7)
R017 Outer annular radius (m), ring 8: not used 0.000E+00 --- RAD_SHAPE( 8)
R017 Outer annular radius (m), ring 9: not used 0.000E+00 --- RAD_SHAPE( 9)
R017 Outer annular radius (m), ring 10: not used 0.000E+00 --- RAD_SHAPE(10)
R017 Outer annular radius (m), ring 11: not used 0.000E+00 --- RAD_SHAPE(11)
R017 Outer annular radius (m), ring 12: not used 0.000E+00 --- RAD_SHAPE(12)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/18/2004 20:27 Page 5 Summary : Yankee Rowe DCGL=concrete grading File : H-3_graded concrete-dcgl.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R017 Fractions of annular areas within AREA:
R017 Ring 1 not used 1.000E+00 --- FRACA( 1)
R017 Ring 2 not used 2.732E-01 --- FRACA( 2)
R017 Ring 3 not used 0.000E+00 --- FRACA( 3)
R017 Ring 4 not used 0.000E+00 --- FRACA( 4)
R017 Ring 5 not used 0.000E+00 --- FRACA( 5)
R017 Ring 6 not used 0.000E+00 --- FRACA( 6)
R017 Ring 7 not used 0.000E+00 --- FRACA( 7)
R017 Ring 8 not used 0.000E+00 --- FRACA( 8)
R017 Ring 9 not used 0.000E+00 --- FRACA( 9)
R017 Ring 10 not used 0.000E+00 --- FRACA(10)
R017 Ring 11 not used 0.000E+00 --- FRACA(11)
R017 Ring 12 not used 0.000E+00 --- FRACA(12)
R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 --- DIET(1)
R018 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 --- DIET(2)
R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 --- DIET(3)
R018 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 --- DIET(4)
R018 Fish consumption (kg/yr) 2.060E+01 5.400E+00 --- DIET(5)
R018 Other seafood consumption (kg/yr) 9.000E-01 9.000E-01 --- DIET(6)
R018 Soil ingestion rate (g/yr) 1.826E+01 3.650E+01 --- SOIL R018 Drinking water intake (L/yr) 4.785E+02 5.100E+02 --- DWI R018 Contamination fraction of drinking water 1.000E+00 1.000E+00 --- FDW R018 Contamination fraction of household water not used 1.000E+00 --- FHHW R018 Contamination fraction of livestock water 1.000E+00 1.000E+00 --- FLW R018 Contamination fraction of irrigation water 1.000E+00 1.000E+00 --- FIRW R018 Contamination fraction of aquatic food 1.000E+00 5.000E-01 --- FR9 R018 Contamination fraction of plant food 1.000E+00 -1 --- FPLANT R018 Contamination fraction of meat 1.000E+00 -1 --- FMEAT R018 Contamination fraction of milk 1.000E+00 -1 --- FMILK R019 Livestock fodder intake for meat (kg/day) 2.710E+01 6.800E+01 --- LFI5 R019 Livestock fodder intake for milk (kg/day) 6.320E+01 5.500E+01 --- LFI6 R019 Livestock water intake for meat (L/day) 5.060E+01 5.000E+01 --- LWI5 R019 Livestock water intake for milk (L/day) 6.000E+01 1.600E+02 --- LWI6 R019 Livestock soil intake (kg/day) 5.000E-01 5.000E-01 --- LSI R019 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.000E-04 --- MLFD R019 Depth of soil mixing layer (m) 2.300E-01 1.500E-01 --- DM R019 Depth of roots (m) 1.174E+00 9.000E-01 --- DROOT R019 Drinking water fraction from ground water 1.000E+00 1.000E+00 --- FGWDW R019 Household water fraction from ground water not used 1.000E+00 --- FGWHH R019 Livestock water fraction from ground water 1.000E+00 1.000E+00 --- FGWLW R019 Irrigation fraction from ground water 1.000E+00 1.000E+00 --- FGWIR R19B Wet weight crop yield for Non-Leafy (kg/m**2) 1.750E+00 7.000E-01 --- YV(1)
R19B Wet weight crop yield for Leafy (kg/m**2) 2.889E+00 1.500E+00 --- YV(2)
R19B Wet weight crop yield for Fodder (kg/m**2) 1.887E+00 1.100E+00 --- YV(3)
R19B Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 --- TE(1)
R19B Growing Season for Leafy (years) 1.230E-01 2.500E-01 --- TE(2)
R19B Growing Season for Fodder (years) 8.200E-02 8.000E-02 --- TE(3)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/18/2004 20:27 Page 6 Summary : Yankee Rowe DCGL=concrete grading File : H-3_graded concrete-dcgl.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R19B Translocation Factor for Non-Leafy 1.000E-01 1.000E-01 --- TIV(1)
R19B Translocation Factor for Leafy 1.000E+00 1.000E+00 --- TIV(2)
R19B Translocation Factor for Fodder 1.000E+00 1.000E+00 --- TIV(3)
R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RDRY(1)
R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 --- RDRY(2)
R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RDRY(3)
R19B Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RWET(1)
R19B Wet Foliar Interception Fraction for Leafy 5.800E-01 2.500E-01 --- RWET(2)
R19B Wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RWET(3)
R19B Weathering Removal Constant for Vegetation 3.300E+01 2.000E+01 --- WLAM C14 C-12 concentration in water (g/cm**3) not used 2.000E-05 --- C12WTR C14 C-12 concentration in contaminated soil (g/g) not used 3.000E-02 --- C12CZ C14 Fraction of vegetation carbon from soil not used 2.000E-02 --- CSOIL C14 Fraction of vegetation carbon from air not used 9.800E-01 --- CAIR C14 C-14 evasion layer thickness in soil (m) not used 3.000E-01 --- DMC C14 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 --- EVSN C14 C-12 evasion flux rate from soil (1/sec) not used 1.000E-10 --- REVSN C14 Fraction of grain in beef cattle feed not used 8.000E-01 --- AVFG4 C14 Fraction of grain in milk cow feed not used 2.000E-01 --- AVFG5 C14 DCF correction factor for gaseous forms of C14 not used 8.894E+01 --- CO2F STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 --- STOR_T(1)
STOR Leafy vegetables 1.000E+00 1.000E+00 --- STOR_T(2)
STOR Milk 1.000E+00 1.000E+00 --- STOR_T(3)
STOR Meat and poultry 2.000E+01 2.000E+01 --- STOR_T(4)
STOR Fish 7.000E+00 7.000E+00 --- STOR_T(5)
STOR Crustacea and mollusks 7.000E+00 7.000E+00 --- STOR_T(6)
STOR Well water 1.000E+00 1.000E+00 --- STOR_T(7)
STOR Surface water 1.000E+00 1.000E+00 --- STOR_T(8)
STOR Livestock fodder 4.500E+01 4.500E+01 --- STOR_T(9)
R021 Thickness of building foundation (m) not used 1.500E-01 --- FLOOR1 R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 --- DENSFL R021 Total porosity of the cover material not used 4.000E-01 --- TPCV R021 Total porosity of the building foundation not used 1.000E-01 --- TPFL R021 Volumetric water content of the cover material not used 5.000E-02 --- PH2OCV R021 Volumetric water content of the foundation not used 3.000E-02 --- PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.000E-06 --- DIFCV R021 in foundation material not used 3.000E-07 --- DIFFL R021 in contaminated zone soil not used 2.000E-06 --- DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.000E+00 --- HMIX R021 Average building air exchange rate (1/hr) not used 5.000E-01 --- REXG R021 Height of the building (room) (m) not used 2.500E+00 --- HRM R021 Building interior area factor not used 0.000E+00 --- FAI R021 Building depth below ground surface (m) not used -1.000E+00 --- DMFL R021 Emanating power of Rn-222 gas not used 2.500E-01 --- EMANA(1)
R021 Emanating power of Rn-220 gas not used 1.500E-01 --- EMANA(2)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/18/2004 20:27 Page 7 Summary : Yankee Rowe DCGL=concrete grading File : H-3_graded concrete-dcgl.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name TITL Number of graphical time points 32 --- --- NPTS TITL Maximum number of integration points for dose 17 --- --- LYMAX TITL Maximum number of integration points for risk 1 --- --- KYMAX Summary of Pathway Selections Pathway User Selection 1 -- external gamma active 2 -- inhalation (w/o radon) active 3 -- plant ingestion active 4 -- meat ingestion active 5 -- milk ingestion active 6 -- aquatic foods active 7 -- drinking water active 8 -- soil ingestion active 9 -- radon suppressed Find peak pathway doses suppressed
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/18/2004 20:27 Page 8 Summary : Yankee Rowe DCGL=concrete grading File : H-3_graded concrete-dcgl.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area: 5020.00 square meters H-3 1.000E+00 Thickness: 2.89 meters Cover Depth: 0.00 meters 0
Total Dose TDOSE(t), mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years): 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 TDOSE(t): 8.239E-02 3.391E-03 3.536E-07 3.731E-21 0.000E+00 0.000E+00 0.000E+00 0.000E+00 M(t): 3.296E-03 1.356E-04 1.414E-08 1.492E-22 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0Maximum TDOSE(t): 8.239E-02 mrem/yr at t = 0.000E+00 years
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/18/2004 20:27 Page 9 Summary : Yankee Rowe DCGL=concrete grading File : H-3_graded concrete-dcgl.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years 0 Water Independent Pathways (Inhalation excludes radon) 0 Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
H-3 0.000E+00 0.0000 4.693E-04 0.0057 0.000E+00 0.0000 3.506E-02 0.4255 5.786E-03 0.0702 3.951E-02 0.4795 1.954E-07 0.0000 Total 0.000E+00 0.0000 4.693E-04 0.0057 0.000E+00 0.0000 3.506E-02 0.4255 5.786E-03 0.0702 3.951E-02 0.4795 1.954E-07 0.0000 0
Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years 0 Water Dependent Pathways 0 Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
H-3 5.376E-04 0.0065 1.873E-05 0.0002 0.000E+00 0.0000 7.616E-04 0.0092 2.373E-05 0.0003 2.276E-04 0.0028 8.239E-02 1.0000 Total 5.376E-04 0.0065 1.873E-05 0.0002 0.000E+00 0.0000 7.616E-04 0.0092 2.373E-05 0.0003 2.276E-04 0.0028 8.239E-02 1.0000 0*Sum of all water independent and dependent pathways.
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/27/2004 09:28 Page 1 Summary : YR concrete-H3-cellar area-DCGL File : H3-concrete-cellar-area-DCGL.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary ... 2 Site-Specific Parameter Summary .......................... 3 Summary of Pathway Selections ............................ 6 Contaminated Zone and Total Dose Summary ................. 7 Total Dose Components Time = 0.000E+00 .................................... 8 Time = 1.000E+00 .................................... 9 Time = 3.000E+00 .................................... 10 Time = 1.000E+01 .................................... 11 Time = 3.000E+01 .................................... 12 Time = 1.000E+02 .................................... 13 Time = 3.000E+02 .................................... 14 Time = 1.000E+03 .................................... 15 Dose/Source Ratios Summed Over All Pathways .............. 16 Single Radionuclide Soil Guidelines ...................... 16 Dose Per Nuclide Summed Over All Pathways ................ 17 Soil Concentration Per Nuclide ........................... 17
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/27/2004 09:28 Page 2 Summary : YR concrete-H3-cellar area-DCGL File : H3-concrete-cellar-area-DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary File: YR Concrete 0 Current Parameter Menu Parameter Value Default Name B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 H-3 6.400E-08 6.400E-08 DCF2( 1)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 H-3 6.400E-08 6.400E-08 DCF3( 1)
D-34 Food transfer factors:
D-34 H-3 , plant/soil concentration ratio, dimensionless 4.800E+00 4.800E+00 RTF( 1,1)
D-34 H-3 , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.200E-02 1.200E-02 RTF( 1,2)
D-34 H-3 , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.000E-02 1.000E-02 RTF( 1,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 H-3 , fish 1.000E+00 1.000E+00 BIOFAC( 1,1)
D-5 H-3 , crustacea and mollusks 1.000E+00 1.000E+00 BIOFAC( 1,2)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/27/2004 09:28 Page 3 Summary : YR concrete-H3-cellar area-DCGL File : H3-concrete-cellar-area-DCGL.RAD Site-Specific Parameter Summary 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R011 Area of contaminated zone (m**2) 1.700E+02 1.000E+04 --- AREA R011 Thickness of contaminated zone (m) 3.800E+00 2.000E+00 --- THICK0 R011 Length parallel to aquifer flow (m) 1.472E+01 1.000E+02 --- LCZPAQ R011 Basic radiation dose limit (mrem/yr) 2.500E+01 2.500E+01 --- BRDL R011 Time since placement of material (yr) 0.000E+00 0.000E+00 --- TI R011 Times for calculations (yr) 1.000E+00 1.000E+00 --- T( 2)
R011 Times for calculations (yr) 3.000E+00 3.000E+00 --- T( 3)
R011 Times for calculations (yr) 1.000E+01 1.000E+01 --- T( 4)
R011 Times for calculations (yr) 3.000E+01 3.000E+01 --- T( 5)
R011 Times for calculations (yr) 1.000E+02 1.000E+02 --- T( 6)
R011 Times for calculations (yr) 3.000E+02 3.000E+02 --- T( 7)
R011 Times for calculations (yr) 1.000E+03 1.000E+03 --- T( 8)
R011 Times for calculations (yr) not used 0.000E+00 --- T( 9)
R011 Times for calculations (yr) not used 0.000E+00 --- T(10)
R012 Initial principal radionuclide (pCi/g): H-3 1.000E+00 0.000E+00 --- S1( 1)
R012 Concentration in groundwater (pCi/L): H-3 not used 0.000E+00 --- W1( 1)
R013 Cover depth (m) 0.000E+00 0.000E+00 --- COVER0 R013 Density of cover material (g/cm**3) not used 1.500E+00 --- DENSCV R013 Cover depth erosion rate (m/yr) not used 1.000E-03 --- VCV R013 Density of contaminated zone (g/cm**3) 1.600E+00 1.500E+00 --- DENSCZ R013 Contaminated zone erosion rate (m/yr) 8.500E-04 1.000E-03 --- VCZ R013 Contaminated zone total porosity 3.000E-01 4.000E-01 --- TPCZ R013 Contaminated zone field capacity 7.000E-02 2.000E-01 --- FCCZ R013 Contaminated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+01 --- HCCZ R013 Contaminated zone b parameter 9.750E-01 5.300E+00 --- BCZ R013 Average annual wind speed (m/sec) 2.030E+00 2.000E+00 --- WIND R013 Humidity in air (g/m**3) 6.100E+00 8.000E+00 --- HUMID R013 Evapotranspiration coefficient 6.250E-01 5.000E-01 --- EVAPTR R013 Precipitation (m/yr) 1.200E+00 1.000E+00 --- PRECIP R013 Irrigation (m/yr) 3.434E-01 2.000E-01 --- RI R013 Irrigation mode overhead overhead --- IDITCH R013 Runoff coefficient 6.000E-01 2.000E-01 --- RUNOFF R013 Watershed area for nearby stream or pond (m**2) 7.770E+05 1.000E+06 --- WAREA R013 Accuracy for water/soil computations 1.000E-03 1.000E-03 --- EPS R014 Density of saturated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSAQ R014 Saturated zone total porosity 2.800E-01 4.000E-01 --- TPSZ R014 Saturated zone effective porosity 2.100E-01 2.000E-01 --- EPSZ R014 Saturated zone field capacity 7.000E-02 2.000E-01 --- FCSZ R014 Saturated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+02 --- HCSZ R014 Saturated zone hydraulic gradient 1.000E-01 2.000E-02 --- HGWT R014 Saturated zone b parameter 9.750E-01 5.300E+00 --- BSZ R014 Water table drop rate (m/yr) 1.000E-03 1.000E-03 --- VWT R014 Well pump intake depth (m below water table) 1.000E+01 1.000E+01 --- DWIBWT R014 Model: Nondispersion (ND) or Mass-Balance (MB) MB ND --- MODEL R014 Well pumping rate (m**3/yr) 5.000E+01 2.500E+02 --- UW R015 Number of unsaturated zone strata 0 1 --- NS
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/27/2004 09:28 Page 4 Summary : YR concrete-H3-cellar area-DCGL File : H3-concrete-cellar-area-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R016 Distribution coefficients for H-3 R016 Contaminated zone (cm**3/g) 0.000E+00 0.000E+00 --- DCNUCC( 1)
R016 Saturated zone (cm**3/g) 0.000E+00 0.000E+00 --- DCNUCS( 1)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 1.161E+00 ALEACH( 1)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 1)
R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 --- INHALR R017 Mass loading for inhalation (g/m**3) 2.330E-05 1.000E-04 --- MLINH R017 Exposure duration 3.000E+01 3.000E+01 --- ED R017 Shielding factor, inhalation 5.500E-01 4.000E-01 --- SHF3 R017 Shielding factor, external gamma 2.725E-01 7.000E-01 --- SHF1 R017 Fraction of time spent indoors 6.571E-01 5.000E-01 --- FIND R017 Fraction of time spent outdoors (on site) 1.181E-01 2.500E-01 --- FOTD R017 Shape factor flag, external gamma 1.000E+00 1.000E+00 >0 shows circular AREA. FS R017 Radii of shape factor array (used if FS = -1):
R017 Outer annular radius (m), ring 1: not used 5.000E+01 --- RAD_SHAPE( 1)
R017 Outer annular radius (m), ring 2: not used 7.071E+01 --- RAD_SHAPE( 2)
R017 Outer annular radius (m), ring 3: not used 0.000E+00 --- RAD_SHAPE( 3)
R017 Outer annular radius (m), ring 4: not used 0.000E+00 --- RAD_SHAPE( 4)
R017 Outer annular radius (m), ring 5: not used 0.000E+00 --- RAD_SHAPE( 5)
R017 Outer annular radius (m), ring 6: not used 0.000E+00 --- RAD_SHAPE( 6)
R017 Outer annular radius (m), ring 7: not used 0.000E+00 --- RAD_SHAPE( 7)
R017 Outer annular radius (m), ring 8: not used 0.000E+00 --- RAD_SHAPE( 8)
R017 Outer annular radius (m), ring 9: not used 0.000E+00 --- RAD_SHAPE( 9)
R017 Outer annular radius (m), ring 10: not used 0.000E+00 --- RAD_SHAPE(10)
R017 Outer annular radius (m), ring 11: not used 0.000E+00 --- RAD_SHAPE(11)
R017 Outer annular radius (m), ring 12: not used 0.000E+00 --- RAD_SHAPE(12)
R017 Fractions of annular areas within AREA:
R017 Ring 1 not used 1.000E+00 --- FRACA( 1)
R017 Ring 2 not used 2.732E-01 --- FRACA( 2)
R017 Ring 3 not used 0.000E+00 --- FRACA( 3)
R017 Ring 4 not used 0.000E+00 --- FRACA( 4)
R017 Ring 5 not used 0.000E+00 --- FRACA( 5)
R017 Ring 6 not used 0.000E+00 --- FRACA( 6)
R017 Ring 7 not used 0.000E+00 --- FRACA( 7)
R017 Ring 8 not used 0.000E+00 --- FRACA( 8)
R017 Ring 9 not used 0.000E+00 --- FRACA( 9)
R017 Ring 10 not used 0.000E+00 --- FRACA(10)
R017 Ring 11 not used 0.000E+00 --- FRACA(11)
R017 Ring 12 not used 0.000E+00 --- FRACA(12)
R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 --- DIET(1)
R018 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 --- DIET(2)
R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 --- DIET(3)
R018 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 --- DIET(4)
R018 Fish consumption (kg/yr) 2.060E+01 5.400E+00 --- DIET(5)
R018 Other seafood consumption (kg/yr) 9.000E-01 9.000E-01 --- DIET(6)
R018 Soil ingestion rate (g/yr) 1.826E+01 3.650E+01 --- SOIL R018 Drinking water intake (L/yr) 4.785E+02 5.100E+02 --- DWI
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/27/2004 09:28 Page 5 Summary : YR concrete-H3-cellar area-DCGL File : H3-concrete-cellar-area-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R018 Contamination fraction of drinking water 1.000E+00 1.000E+00 --- FDW R018 Contamination fraction of household water not used 1.000E+00 --- FHHW R018 Contamination fraction of livestock water 1.000E+00 1.000E+00 --- FLW R018 Contamination fraction of irrigation water 1.000E+00 1.000E+00 --- FIRW R018 Contamination fraction of aquatic food 1.000E+00 5.000E-01 --- FR9 R018 Contamination fraction of plant food -1 -1 0.850E-01 FPLANT R018 Contamination fraction of meat -1 -1 0.850E-02 FMEAT R018 Contamination fraction of milk -1 -1 0.850E-02 FMILK R019 Livestock fodder intake for meat (kg/day) 2.710E+01 6.800E+01 --- LFI5 R019 Livestock fodder intake for milk (kg/day) 6.320E+01 5.500E+01 --- LFI6 R019 Livestock water intake for meat (L/day) 5.060E+01 5.000E+01 --- LWI5 R019 Livestock water intake for milk (L/day) 6.000E+01 1.600E+02 --- LWI6 R019 Livestock soil intake (kg/day) 5.000E-01 5.000E-01 --- LSI R019 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.000E-04 --- MLFD R019 Depth of soil mixing layer (m) 2.300E-01 1.500E-01 --- DM R019 Depth of roots (m) 2.050E+00 9.000E-01 --- DROOT R019 Drinking water fraction from ground water 1.000E+00 1.000E+00 --- FGWDW R019 Household water fraction from ground water not used 1.000E+00 --- FGWHH R019 Livestock water fraction from ground water 1.000E+00 1.000E+00 --- FGWLW R019 Irrigation fraction from ground water 1.000E+00 1.000E+00 --- FGWIR R19B Wet weight crop yield for Non-Leafy (kg/m**2) 1.750E+00 7.000E-01 --- YV(1)
R19B Wet weight crop yield for Leafy (kg/m**2) 2.889E+00 1.500E+00 --- YV(2)
R19B Wet weight crop yield for Fodder (kg/m**2) 1.887E+00 1.100E+00 --- YV(3)
R19B Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 --- TE(1)
R19B Growing Season for Leafy (years) 1.230E-01 2.500E-01 --- TE(2)
R19B Growing Season for Fodder (years) 8.200E-02 8.000E-02 --- TE(3)
R19B Translocation Factor for Non-Leafy 1.000E-01 1.000E-01 --- TIV(1)
R19B Translocation Factor for Leafy 1.000E+00 1.000E+00 --- TIV(2)
R19B Translocation Factor for Fodder 1.000E+00 1.000E+00 --- TIV(3)
R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RDRY(1)
R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 --- RDRY(2)
R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RDRY(3)
R19B Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RWET(1)
R19B Wet Foliar Interception Fraction for Leafy 5.800E-01 2.500E-01 --- RWET(2)
R19B Wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RWET(3)
R19B Weathering Removal Constant for Vegetation 3.300E+01 2.000E+01 --- WLAM C14 C-12 concentration in water (g/cm**3) not used 2.000E-05 --- C12WTR C14 C-12 concentration in contaminated soil (g/g) not used 3.000E-02 --- C12CZ C14 Fraction of vegetation carbon from soil not used 2.000E-02 --- CSOIL C14 Fraction of vegetation carbon from air not used 9.800E-01 --- CAIR C14 C-14 evasion layer thickness in soil (m) not used 3.000E-01 --- DMC C14 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 --- EVSN C14 C-12 evasion flux rate from soil (1/sec) not used 1.000E-10 --- REVSN C14 Fraction of grain in beef cattle feed not used 8.000E-01 --- AVFG4 C14 Fraction of grain in milk cow feed not used 2.000E-01 --- AVFG5 C14 DCF correction factor for gaseous forms of C14 not used 8.894E+01 --- CO2F
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/27/2004 09:28 Page 6 Summary : YR concrete-H3-cellar area-DCGL File : H3-concrete-cellar-area-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 --- STOR_T(1)
STOR Leafy vegetables 1.000E+00 1.000E+00 --- STOR_T(2)
STOR Milk 1.000E+00 1.000E+00 --- STOR_T(3)
STOR Meat and poultry 2.000E+01 2.000E+01 --- STOR_T(4)
STOR Fish 7.000E+00 7.000E+00 --- STOR_T(5)
STOR Crustacea and mollusks 7.000E+00 7.000E+00 --- STOR_T(6)
STOR Well water 1.000E+00 1.000E+00 --- STOR_T(7)
STOR Surface water 1.000E+00 1.000E+00 --- STOR_T(8)
STOR Livestock fodder 4.500E+01 4.500E+01 --- STOR_T(9)
R021 Thickness of building foundation (m) not used 1.500E-01 --- FLOOR1 R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 --- DENSFL R021 Total porosity of the cover material not used 4.000E-01 --- TPCV R021 Total porosity of the building foundation not used 1.000E-01 --- TPFL R021 Volumetric water content of the cover material not used 5.000E-02 --- PH2OCV R021 Volumetric water content of the foundation not used 3.000E-02 --- PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.000E-06 --- DIFCV R021 in foundation material not used 3.000E-07 --- DIFFL R021 in contaminated zone soil not used 2.000E-06 --- DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.000E+00 --- HMIX R021 Average building air exchange rate (1/hr) not used 5.000E-01 --- REXG R021 Height of the building (room) (m) not used 2.500E+00 --- HRM R021 Building interior area factor not used 0.000E+00 --- FAI R021 Building depth below ground surface (m) not used -1.000E+00 --- DMFL R021 Emanating power of Rn-222 gas not used 2.500E-01 --- EMANA(1)
R021 Emanating power of Rn-220 gas not used 1.500E-01 --- EMANA(2)
TITL Number of graphical time points 32 --- --- NPTS TITL Maximum number of integration points for dose 17 --- --- LYMAX TITL Maximum number of integration points for risk 1 --- --- KYMAX Summary of Pathway Selections Pathway User Selection 1 -- external gamma active 2 -- inhalation (w/o radon) active 3 -- plant ingestion active 4 -- meat ingestion active 5 -- milk ingestion active 6 -- aquatic foods active 7 -- drinking water active 8 -- soil ingestion active 9 -- radon suppressed Find peak pathway doses suppressed
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/27/2004 09:28 Page 7 Summary : YR concrete-H3-cellar area-DCGL File : H3-concrete-cellar-area-DCGL.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area: 170.00 square meters H-3 1.000E+00 Thickness: 3.80 meters Cover Depth: 0.00 meters 0
Total Dose TDOSE(t), mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years): 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 TDOSE(t): 2.470E-01 1.261E-02 2.285E-05 5.639E-15 0.000E+00 0.000E+00 0.000E+00 0.000E+00 M(t): 9.882E-03 5.043E-04 9.141E-07 2.256E-16 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0Maximum TDOSE(t): 2.470E-01 mrem/yr at t = 0.000E+00 years
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/27/2004 09:28 Page 8 Summary : YR concrete-H3-cellar area-DCGL File : H3-concrete-cellar-area-DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years 0 Water Independent Pathways (Inhalation excludes radon) 0 Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
H-3 0.000E+00 0.0000 1.136E-04 0.0005 0.000E+00 0.0000 4.290E-03 0.0174 6.414E-05 0.0003 4.570E-04 0.0018 4.673E-08 0.0000 Total 0.000E+00 0.0000 1.136E-04 0.0005 0.000E+00 0.0000 4.290E-03 0.0174 6.414E-05 0.0003 4.570E-04 0.0018 4.673E-08 0.0000 0
Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years 0 Water Dependent Pathways 0 Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
H-3 2.103E-01 0.8513 2.155E-06 0.0000 0.000E+00 0.0000 2.996E-02 0.1213 2.587E-04 0.0010 1.591E-03 0.0064 2.470E-01 1.0000 Total 2.103E-01 0.8513 2.155E-06 0.0000 0.000E+00 0.0000 2.996E-02 0.1213 2.587E-04 0.0010 1.591E-03 0.0064 2.470E-01 1.0000 0*Sum of all water independent and dependent pathways.
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 12:44 Page 1 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Nb94-concrete-DCGL.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary ... 2 Site-Specific Parameter Summary .......................... 3 Summary of Pathway Selections ............................ 6 Contaminated Zone and Total Dose Summary ................. 7 Total Dose Components Time = 0.000E+00 .................................... 8 Time = 1.000E+00 .................................... 9 Time = 3.000E+00 .................................... 10 Time = 1.000E+01 .................................... 11 Time = 3.000E+01 .................................... 12 Time = 1.000E+02 .................................... 13 Time = 3.000E+02 .................................... 14 Time = 1.000E+03 .................................... 15 Dose/Source Ratios Summed Over All Pathways .............. 16 Single Radionuclide Soil Guidelines ...................... 16 Dose Per Nuclide Summed Over All Pathways ................ 17 Soil Concentration Per Nuclide ........................... 17
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 12:44 Page 2 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Nb94-concrete-DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary File: YR Concrete 0 Current Parameter Menu Parameter Value Default Name B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 Nb-94 4.140E-04 4.140E-04 DCF2( 1)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Nb-94 7.140E-06 7.140E-06 DCF3( 1)
D-34 Food transfer factors:
D-34 Nb-94 , plant/soil concentration ratio, dimensionless 1.460E-03 1.000E-02 RTF( 1,1)
D-34 Nb-94 , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.000E-06 3.000E-07 RTF( 1,2)
D-34 Nb-94 , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 2.000E-06 2.000E-06 RTF( 1,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Nb-94 , fish 3.000E+02 3.000E+02 BIOFAC( 1,1)
D-5 Nb-94 , crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC( 1,2)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 12:44 Page 3 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Nb94-concrete-DCGL.RAD Site-Specific Parameter Summary 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R011 Area of contaminated zone (m**2) 5.020E+03 1.000E+04 --- AREA R011 Thickness of contaminated zone (m) 3.800E+00 2.000E+00 --- THICK0 R011 Length parallel to aquifer flow (m) 8.000E+01 1.000E+02 --- LCZPAQ R011 Basic radiation dose limit (mrem/yr) 2.500E+01 2.500E+01 --- BRDL R011 Time since placement of material (yr) 0.000E+00 0.000E+00 --- TI R011 Times for calculations (yr) 1.000E+00 1.000E+00 --- T( 2)
R011 Times for calculations (yr) 3.000E+00 3.000E+00 --- T( 3)
R011 Times for calculations (yr) 1.000E+01 1.000E+01 --- T( 4)
R011 Times for calculations (yr) 3.000E+01 3.000E+01 --- T( 5)
R011 Times for calculations (yr) 1.000E+02 1.000E+02 --- T( 6)
R011 Times for calculations (yr) 3.000E+02 3.000E+02 --- T( 7)
R011 Times for calculations (yr) 1.000E+03 1.000E+03 --- T( 8)
R011 Times for calculations (yr) not used 0.000E+00 --- T( 9)
R011 Times for calculations (yr) not used 0.000E+00 --- T(10)
R012 Initial principal radionuclide (pCi/g): Nb-94 1.000E+00 0.000E+00 --- S1( 1)
R012 Concentration in groundwater (pCi/L): Nb-94 not used 0.000E+00 --- W1( 1)
R013 Cover depth (m) 0.000E+00 0.000E+00 --- COVER0 R013 Density of cover material (g/cm**3) not used 1.500E+00 --- DENSCV R013 Cover depth erosion rate (m/yr) not used 1.000E-03 --- VCV R013 Density of contaminated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSCZ R013 Contaminated zone erosion rate (m/yr) 8.500E-04 1.000E-03 --- VCZ R013 Contaminated zone total porosity 3.000E-01 4.000E-01 --- TPCZ R013 Contaminated zone field capacity 7.000E-02 2.000E-01 --- FCCZ R013 Contaminated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+01 --- HCCZ R013 Contaminated zone b parameter 9.750E-01 5.300E+00 --- BCZ R013 Average annual wind speed (m/sec) 2.030E+00 2.000E+00 --- WIND R013 Humidity in air (g/m**3) not used 8.000E+00 --- HUMID R013 Evapotranspiration coefficient 6.250E-01 5.000E-01 --- EVAPTR R013 Precipitation (m/yr) 1.200E+00 1.000E+00 --- PRECIP R013 Irrigation (m/yr) 4.350E-01 2.000E-01 --- RI R013 Irrigation mode overhead overhead --- IDITCH R013 Runoff coefficient 6.000E-01 2.000E-01 --- RUNOFF R013 Watershed area for nearby stream or pond (m**2) 7.770E+05 1.000E+06 --- WAREA R013 Accuracy for water/soil computations 1.000E-03 1.000E-03 --- EPS R014 Density of saturated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSAQ R014 Saturated zone total porosity 2.800E-01 4.000E-01 --- TPSZ R014 Saturated zone effective porosity 2.100E-01 2.000E-01 --- EPSZ R014 Saturated zone field capacity 7.000E-02 2.000E-01 --- FCSZ R014 Saturated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+02 --- HCSZ R014 Saturated zone hydraulic gradient 1.000E-01 2.000E-02 --- HGWT R014 Saturated zone b parameter 9.750E-01 5.300E+00 --- BSZ R014 Water table drop rate (m/yr) 1.000E-03 1.000E-03 --- VWT R014 Well pump intake depth (m below water table) 1.000E+01 1.000E+01 --- DWIBWT R014 Model: Nondispersion (ND) or Mass-Balance (MB) MB ND --- MODEL R014 Well pumping rate (m**3/yr) 2.500E+02 2.500E+02 --- UW R015 Number of unsaturated zone strata 0 1 --- NS
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 12:44 Page 4 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Nb94-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R016 Distribution coefficients for Nb-94 R016 Contaminated zone (cm**3/g) 3.160E+02 0.000E+00 --- DCNUCC( 1)
R016 Saturated zone (cm**3/g) 0.000E+00 0.000E+00 --- DCNUCS( 1)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 1.855E-04 ALEACH( 1)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 1)
R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 --- INHALR R017 Mass loading for inhalation (g/m**3) 2.330E-05 1.000E-04 --- MLINH R017 Exposure duration 3.000E+01 3.000E+01 --- ED R017 Shielding factor, inhalation 5.500E-01 4.000E-01 --- SHF3 R017 Shielding factor, external gamma 3.980E-01 7.000E-01 --- SHF1 R017 Fraction of time spent indoors 6.571E-01 5.000E-01 --- FIND R017 Fraction of time spent outdoors (on site) 1.181E-01 2.500E-01 --- FOTD R017 Shape factor flag, external gamma 1.000E+00 1.000E+00 >0 shows circular AREA. FS R017 Radii of shape factor array (used if FS = -1):
R017 Outer annular radius (m), ring 1: not used 5.000E+01 --- RAD_SHAPE( 1)
R017 Outer annular radius (m), ring 2: not used 7.071E+01 --- RAD_SHAPE( 2)
R017 Outer annular radius (m), ring 3: not used 0.000E+00 --- RAD_SHAPE( 3)
R017 Outer annular radius (m), ring 4: not used 0.000E+00 --- RAD_SHAPE( 4)
R017 Outer annular radius (m), ring 5: not used 0.000E+00 --- RAD_SHAPE( 5)
R017 Outer annular radius (m), ring 6: not used 0.000E+00 --- RAD_SHAPE( 6)
R017 Outer annular radius (m), ring 7: not used 0.000E+00 --- RAD_SHAPE( 7)
R017 Outer annular radius (m), ring 8: not used 0.000E+00 --- RAD_SHAPE( 8)
R017 Outer annular radius (m), ring 9: not used 0.000E+00 --- RAD_SHAPE( 9)
R017 Outer annular radius (m), ring 10: not used 0.000E+00 --- RAD_SHAPE(10)
R017 Outer annular radius (m), ring 11: not used 0.000E+00 --- RAD_SHAPE(11)
R017 Outer annular radius (m), ring 12: not used 0.000E+00 --- RAD_SHAPE(12)
R017 Fractions of annular areas within AREA:
R017 Ring 1 not used 1.000E+00 --- FRACA( 1)
R017 Ring 2 not used 2.732E-01 --- FRACA( 2)
R017 Ring 3 not used 0.000E+00 --- FRACA( 3)
R017 Ring 4 not used 0.000E+00 --- FRACA( 4)
R017 Ring 5 not used 0.000E+00 --- FRACA( 5)
R017 Ring 6 not used 0.000E+00 --- FRACA( 6)
R017 Ring 7 not used 0.000E+00 --- FRACA( 7)
R017 Ring 8 not used 0.000E+00 --- FRACA( 8)
R017 Ring 9 not used 0.000E+00 --- FRACA( 9)
R017 Ring 10 not used 0.000E+00 --- FRACA(10)
R017 Ring 11 not used 0.000E+00 --- FRACA(11)
R017 Ring 12 not used 0.000E+00 --- FRACA(12)
R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 --- DIET(1)
R018 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 --- DIET(2)
R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 --- DIET(3)
R018 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 --- DIET(4)
R018 Fish consumption (kg/yr) 2.060E+01 5.400E+00 --- DIET(5)
R018 Other seafood consumption (kg/yr) 9.000E-01 9.000E-01 --- DIET(6)
R018 Soil ingestion rate (g/yr) 1.826E+01 3.650E+01 --- SOIL R018 Drinking water intake (L/yr) 4.785E+02 5.100E+02 --- DWI
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 12:44 Page 5 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Nb94-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R018 Contamination fraction of drinking water 1.000E+00 1.000E+00 --- FDW R018 Contamination fraction of household water not used 1.000E+00 --- FHHW R018 Contamination fraction of livestock water 1.000E+00 1.000E+00 --- FLW R018 Contamination fraction of irrigation water 1.000E+00 1.000E+00 --- FIRW R018 Contamination fraction of aquatic food 1.000E+00 5.000E-01 --- FR9 R018 Contamination fraction of plant food 1.000E+00 -1 --- FPLANT R018 Contamination fraction of meat 1.000E+00 -1 --- FMEAT R018 Contamination fraction of milk 1.000E+00 -1 --- FMILK R019 Livestock fodder intake for meat (kg/day) 2.710E+01 6.800E+01 --- LFI5 R019 Livestock fodder intake for milk (kg/day) 6.320E+01 5.500E+01 --- LFI6 R019 Livestock water intake for meat (L/day) 5.060E+01 5.000E+01 --- LWI5 R019 Livestock water intake for milk (L/day) 6.000E+01 1.600E+02 --- LWI6 R019 Livestock soil intake (kg/day) 5.000E-01 5.000E-01 --- LSI R019 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.000E-04 --- MLFD R019 Depth of soil mixing layer (m) 2.300E-01 1.500E-01 --- DM R019 Depth of roots (m) 2.050E+00 9.000E-01 --- DROOT R019 Drinking water fraction from ground water 1.000E+00 1.000E+00 --- FGWDW R019 Household water fraction from ground water not used 1.000E+00 --- FGWHH R019 Livestock water fraction from ground water 1.000E+00 1.000E+00 --- FGWLW R019 Irrigation fraction from ground water 1.000E+00 1.000E+00 --- FGWIR R19B Wet weight crop yield for Non-Leafy (kg/m**2) 1.750E+00 7.000E-01 --- YV(1)
R19B Wet weight crop yield for Leafy (kg/m**2) 2.889E+00 1.500E+00 --- YV(2)
R19B Wet weight crop yield for Fodder (kg/m**2) 1.887E+00 1.100E+00 --- YV(3)
R19B Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 --- TE(1)
R19B Growing Season for Leafy (years) 1.230E-01 2.500E-01 --- TE(2)
R19B Growing Season for Fodder (years) 8.200E-02 8.000E-02 --- TE(3)
R19B Translocation Factor for Non-Leafy 1.000E-01 1.000E-01 --- TIV(1)
R19B Translocation Factor for Leafy 1.000E+00 1.000E+00 --- TIV(2)
R19B Translocation Factor for Fodder 1.000E+00 1.000E+00 --- TIV(3)
R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RDRY(1)
R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 --- RDRY(2)
R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RDRY(3)
R19B Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RWET(1)
R19B Wet Foliar Interception Fraction for Leafy 5.800E-01 2.500E-01 --- RWET(2)
R19B Wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RWET(3)
R19B Weathering Removal Constant for Vegetation 3.300E+01 2.000E+01 --- WLAM C14 C-12 concentration in water (g/cm**3) not used 2.000E-05 --- C12WTR C14 C-12 concentration in contaminated soil (g/g) not used 3.000E-02 --- C12CZ C14 Fraction of vegetation carbon from soil not used 2.000E-02 --- CSOIL C14 Fraction of vegetation carbon from air not used 9.800E-01 --- CAIR C14 C-14 evasion layer thickness in soil (m) not used 3.000E-01 --- DMC C14 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 --- EVSN C14 C-12 evasion flux rate from soil (1/sec) not used 1.000E-10 --- REVSN C14 Fraction of grain in beef cattle feed not used 8.000E-01 --- AVFG4 C14 Fraction of grain in milk cow feed not used 2.000E-01 --- AVFG5 C14 DCF correction factor for gaseous forms of C14 not used 8.894E+01 --- CO2F
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 12:44 Page 6 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Nb94-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 --- STOR_T(1)
STOR Leafy vegetables 1.000E+00 1.000E+00 --- STOR_T(2)
STOR Milk 1.000E+00 1.000E+00 --- STOR_T(3)
STOR Meat and poultry 2.000E+01 2.000E+01 --- STOR_T(4)
STOR Fish 7.000E+00 7.000E+00 --- STOR_T(5)
STOR Crustacea and mollusks 7.000E+00 7.000E+00 --- STOR_T(6)
STOR Well water 1.000E+00 1.000E+00 --- STOR_T(7)
STOR Surface water 1.000E+00 1.000E+00 --- STOR_T(8)
STOR Livestock fodder 4.500E+01 4.500E+01 --- STOR_T(9)
R021 Thickness of building foundation (m) not used 1.500E-01 --- FLOOR1 R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 --- DENSFL R021 Total porosity of the cover material not used 4.000E-01 --- TPCV R021 Total porosity of the building foundation not used 1.000E-01 --- TPFL R021 Volumetric water content of the cover material not used 5.000E-02 --- PH2OCV R021 Volumetric water content of the foundation not used 3.000E-02 --- PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.000E-06 --- DIFCV R021 in foundation material not used 3.000E-07 --- DIFFL R021 in contaminated zone soil not used 2.000E-06 --- DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.000E+00 --- HMIX R021 Average building air exchange rate (1/hr) not used 5.000E-01 --- REXG R021 Height of the building (room) (m) not used 2.500E+00 --- HRM R021 Building interior area factor not used 0.000E+00 --- FAI R021 Building depth below ground surface (m) not used -1.000E+00 --- DMFL R021 Emanating power of Rn-222 gas not used 2.500E-01 --- EMANA(1)
R021 Emanating power of Rn-220 gas not used 1.500E-01 --- EMANA(2)
TITL Number of graphical time points 32 --- --- NPTS TITL Maximum number of integration points for dose 17 --- --- LYMAX TITL Maximum number of integration points for risk 1 --- --- KYMAX Summary of Pathway Selections Pathway User Selection 1 -- external gamma active 2 -- inhalation (w/o radon) active 3 -- plant ingestion active 4 -- meat ingestion active 5 -- milk ingestion active 6 -- aquatic foods active 7 -- drinking water active 8 -- soil ingestion active 9 -- radon suppressed Find peak pathway doses suppressed
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 12:44 Page 7 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Nb94-concrete-DCGL.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area: 5020.00 square meters Nb-94 1.000E+00 Thickness: 3.80 meters Cover Depth: 0.00 meters 0
Total Dose TDOSE(t), mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years): 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 TDOSE(t): 3.399E+00 3.399E+00 3.397E+00 3.392E+00 3.377E+00 3.325E+00 3.182E+00 2.727E+00 M(t): 1.360E-01 1.360E-01 1.359E-01 1.357E-01 1.351E-01 1.330E-01 1.273E-01 1.091E-01 0Maximum TDOSE(t): 3.399E+00 mrem/yr at t = 0.000E+00 years
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/05/2004 12:44 Page 8 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Nb94-concrete-DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years 0 Water Independent Pathways (Inhalation excludes radon) 0 Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Nb-94 3.384E+00 0.9957 6.127E-06 0.0000 0.000E+00 0.0000 1.393E-03 0.0004 2.509E-07 0.0000 1.973E-06 0.0000 1.011E-04 0.0000 Total 3.384E+00 0.9957 6.127E-06 0.0000 0.000E+00 0.0000 1.393E-03 0.0004 2.509E-07 0.0000 1.973E-06 0.0000 1.011E-04 0.0000 0
Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years 0 Water Dependent Pathways 0 Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Nb-94 1.025E-02 0.0030 8.685E-04 0.0003 0.000E+00 0.0000 1.826E-03 0.0005 1.485E-07 0.0000 1.986E-06 0.0000 3.399E+00 1.0000 Total 1.025E-02 0.0030 8.685E-04 0.0003 0.000E+00 0.0000 1.826E-03 0.0005 1.485E-07 0.0000 1.986E-06 0.0000 3.399E+00 1.0000 0*Sum of all water independent and dependent pathways.
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:49 Page 1 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Ni63-concrete-DCGL.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary ... 2 Site-Specific Parameter Summary .......................... 3 Summary of Pathway Selections ............................ 6 Contaminated Zone and Total Dose Summary ................. 7 Total Dose Components Time = 0.000E+00 .................................... 8 Time = 1.000E+00 .................................... 9 Time = 3.000E+00 .................................... 10 Time = 1.000E+01 .................................... 11 Time = 3.000E+01 .................................... 12 Time = 1.000E+02 .................................... 13 Time = 3.000E+02 .................................... 14 Time = 1.000E+03 .................................... 15 Dose/Source Ratios Summed Over All Pathways .............. 16 Single Radionuclide Soil Guidelines ...................... 16 Dose Per Nuclide Summed Over All Pathways ................ 17 Soil Concentration Per Nuclide ........................... 17
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:49 Page 2 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Ni63-concrete-DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary File: YR Concrete 0 Current Parameter Menu Parameter Value Default Name B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 Ni-63 6.290E-06 6.290E-06 DCF2( 1)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Ni-63 5.770E-07 5.770E-07 DCF3( 1)
D-34 Food transfer factors:
D-34 Ni-63 , plant/soil concentration ratio, dimensionless 5.290E-01 5.000E-02 RTF( 1,1)
D-34 Ni-63 , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 5.000E-03 5.000E-03 RTF( 1,2)
D-34 Ni-63 , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 3.210E-02 2.000E-02 RTF( 1,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Ni-63 , fish 9.900E+01 1.000E+02 BIOFAC( 1,1)
D-5 Ni-63 , crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC( 1,2)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:49 Page 3 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Ni63-concrete-DCGL.RAD Site-Specific Parameter Summary 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R011 Area of contaminated zone (m**2) 5.020E+03 1.000E+04 --- AREA R011 Thickness of contaminated zone (m) 3.800E+00 2.000E+00 --- THICK0 R011 Length parallel to aquifer flow (m) 8.000E+01 1.000E+02 --- LCZPAQ R011 Basic radiation dose limit (mrem/yr) 2.500E+01 2.500E+01 --- BRDL R011 Time since placement of material (yr) 0.000E+00 0.000E+00 --- TI R011 Times for calculations (yr) 1.000E+00 1.000E+00 --- T( 2)
R011 Times for calculations (yr) 3.000E+00 3.000E+00 --- T( 3)
R011 Times for calculations (yr) 1.000E+01 1.000E+01 --- T( 4)
R011 Times for calculations (yr) 3.000E+01 3.000E+01 --- T( 5)
R011 Times for calculations (yr) 1.000E+02 1.000E+02 --- T( 6)
R011 Times for calculations (yr) 3.000E+02 3.000E+02 --- T( 7)
R011 Times for calculations (yr) 1.000E+03 1.000E+03 --- T( 8)
R011 Times for calculations (yr) not used 0.000E+00 --- T( 9)
R011 Times for calculations (yr) not used 0.000E+00 --- T(10)
R012 Initial principal radionuclide (pCi/g): Ni-63 1.000E+00 0.000E+00 --- S1( 1)
R012 Concentration in groundwater (pCi/L): Ni-63 not used 0.000E+00 --- W1( 1)
R013 Cover depth (m) 0.000E+00 0.000E+00 --- COVER0 R013 Density of cover material (g/cm**3) not used 1.500E+00 --- DENSCV R013 Cover depth erosion rate (m/yr) not used 1.000E-03 --- VCV R013 Density of contaminated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSCZ R013 Contaminated zone erosion rate (m/yr) 8.500E-04 1.000E-03 --- VCZ R013 Contaminated zone total porosity 3.000E-01 4.000E-01 --- TPCZ R013 Contaminated zone field capacity 7.000E-02 2.000E-01 --- FCCZ R013 Contaminated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+01 --- HCCZ R013 Contaminated zone b parameter 9.750E-01 5.300E+00 --- BCZ R013 Average annual wind speed (m/sec) 2.030E+00 2.000E+00 --- WIND R013 Humidity in air (g/m**3) not used 8.000E+00 --- HUMID R013 Evapotranspiration coefficient 6.250E-01 5.000E-01 --- EVAPTR R013 Precipitation (m/yr) 1.200E+00 1.000E+00 --- PRECIP R013 Irrigation (m/yr) 4.350E-01 2.000E-01 --- RI R013 Irrigation mode overhead overhead --- IDITCH R013 Runoff coefficient 6.000E-01 2.000E-01 --- RUNOFF R013 Watershed area for nearby stream or pond (m**2) 7.770E+05 1.000E+06 --- WAREA R013 Accuracy for water/soil computations 1.000E-03 1.000E-03 --- EPS R014 Density of saturated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSAQ R014 Saturated zone total porosity 2.800E-01 4.000E-01 --- TPSZ R014 Saturated zone effective porosity 2.100E-01 2.000E-01 --- EPSZ R014 Saturated zone field capacity 7.000E-02 2.000E-01 --- FCSZ R014 Saturated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+02 --- HCSZ R014 Saturated zone hydraulic gradient 1.000E-01 2.000E-02 --- HGWT R014 Saturated zone b parameter 9.750E-01 5.300E+00 --- BSZ R014 Water table drop rate (m/yr) 1.000E-03 1.000E-03 --- VWT R014 Well pump intake depth (m below water table) 1.000E+01 1.000E+01 --- DWIBWT R014 Model: Nondispersion (ND) or Mass-Balance (MB) MB ND --- MODEL R014 Well pumping rate (m**3/yr) 2.500E+02 2.500E+02 --- UW R015 Number of unsaturated zone strata 0 1 --- NS
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:49 Page 4 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Ni63-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R016 Distribution coefficients for Ni-63 R016 Contaminated zone (cm**3/g) 3.550E+01 1.000E+03 --- DCNUCC( 1)
R016 Saturated zone (cm**3/g) 0.000E+00 1.000E+03 --- DCNUCS( 1)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 1.650E-03 ALEACH( 1)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 1)
R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 --- INHALR R017 Mass loading for inhalation (g/m**3) 2.330E-05 1.000E-04 --- MLINH R017 Exposure duration 3.000E+01 3.000E+01 --- ED R017 Shielding factor, inhalation 5.500E-01 4.000E-01 --- SHF3 R017 Shielding factor, external gamma 2.725E-01 7.000E-01 --- SHF1 R017 Fraction of time spent indoors 6.571E-01 5.000E-01 --- FIND R017 Fraction of time spent outdoors (on site) 1.181E-01 2.500E-01 --- FOTD R017 Shape factor flag, external gamma 1.000E+00 1.000E+00 >0 shows circular AREA. FS R017 Radii of shape factor array (used if FS = -1):
R017 Outer annular radius (m), ring 1: not used 5.000E+01 --- RAD_SHAPE( 1)
R017 Outer annular radius (m), ring 2: not used 7.071E+01 --- RAD_SHAPE( 2)
R017 Outer annular radius (m), ring 3: not used 0.000E+00 --- RAD_SHAPE( 3)
R017 Outer annular radius (m), ring 4: not used 0.000E+00 --- RAD_SHAPE( 4)
R017 Outer annular radius (m), ring 5: not used 0.000E+00 --- RAD_SHAPE( 5)
R017 Outer annular radius (m), ring 6: not used 0.000E+00 --- RAD_SHAPE( 6)
R017 Outer annular radius (m), ring 7: not used 0.000E+00 --- RAD_SHAPE( 7)
R017 Outer annular radius (m), ring 8: not used 0.000E+00 --- RAD_SHAPE( 8)
R017 Outer annular radius (m), ring 9: not used 0.000E+00 --- RAD_SHAPE( 9)
R017 Outer annular radius (m), ring 10: not used 0.000E+00 --- RAD_SHAPE(10)
R017 Outer annular radius (m), ring 11: not used 0.000E+00 --- RAD_SHAPE(11)
R017 Outer annular radius (m), ring 12: not used 0.000E+00 --- RAD_SHAPE(12)
R017 Fractions of annular areas within AREA:
R017 Ring 1 not used 1.000E+00 --- FRACA( 1)
R017 Ring 2 not used 2.732E-01 --- FRACA( 2)
R017 Ring 3 not used 0.000E+00 --- FRACA( 3)
R017 Ring 4 not used 0.000E+00 --- FRACA( 4)
R017 Ring 5 not used 0.000E+00 --- FRACA( 5)
R017 Ring 6 not used 0.000E+00 --- FRACA( 6)
R017 Ring 7 not used 0.000E+00 --- FRACA( 7)
R017 Ring 8 not used 0.000E+00 --- FRACA( 8)
R017 Ring 9 not used 0.000E+00 --- FRACA( 9)
R017 Ring 10 not used 0.000E+00 --- FRACA(10)
R017 Ring 11 not used 0.000E+00 --- FRACA(11)
R017 Ring 12 not used 0.000E+00 --- FRACA(12)
R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 --- DIET(1)
R018 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 --- DIET(2)
R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 --- DIET(3)
R018 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 --- DIET(4)
R018 Fish consumption (kg/yr) 2.060E+01 5.400E+00 --- DIET(5)
R018 Other seafood consumption (kg/yr) 9.000E-01 9.000E-01 --- DIET(6)
R018 Soil ingestion rate (g/yr) 1.826E+01 3.650E+01 --- SOIL R018 Drinking water intake (L/yr) 4.785E+02 5.100E+02 --- DWI
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:49 Page 5 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Ni63-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R018 Contamination fraction of drinking water 1.000E+00 1.000E+00 --- FDW R018 Contamination fraction of household water not used 1.000E+00 --- FHHW R018 Contamination fraction of livestock water 1.000E+00 1.000E+00 --- FLW R018 Contamination fraction of irrigation water 1.000E+00 1.000E+00 --- FIRW R018 Contamination fraction of aquatic food 1.000E+00 5.000E-01 --- FR9 R018 Contamination fraction of plant food 1.000E+00 -1 --- FPLANT R018 Contamination fraction of meat 1.000E+00 -1 --- FMEAT R018 Contamination fraction of milk 1.000E+00 -1 --- FMILK R019 Livestock fodder intake for meat (kg/day) 2.710E+01 6.800E+01 --- LFI5 R019 Livestock fodder intake for milk (kg/day) 6.320E+01 5.500E+01 --- LFI6 R019 Livestock water intake for meat (L/day) 5.060E+01 5.000E+01 --- LWI5 R019 Livestock water intake for milk (L/day) 6.000E+01 1.600E+02 --- LWI6 R019 Livestock soil intake (kg/day) 5.000E-01 5.000E-01 --- LSI R019 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.000E-04 --- MLFD R019 Depth of soil mixing layer (m) 2.300E-01 1.500E-01 --- DM R019 Depth of roots (m) 2.050E+00 9.000E-01 --- DROOT R019 Drinking water fraction from ground water 1.000E+00 1.000E+00 --- FGWDW R019 Household water fraction from ground water not used 1.000E+00 --- FGWHH R019 Livestock water fraction from ground water 1.000E+00 1.000E+00 --- FGWLW R019 Irrigation fraction from ground water 1.000E+00 1.000E+00 --- FGWIR R19B Wet weight crop yield for Non-Leafy (kg/m**2) 1.750E+00 7.000E-01 --- YV(1)
R19B Wet weight crop yield for Leafy (kg/m**2) 2.889E+00 1.500E+00 --- YV(2)
R19B Wet weight crop yield for Fodder (kg/m**2) 1.887E+00 1.100E+00 --- YV(3)
R19B Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 --- TE(1)
R19B Growing Season for Leafy (years) 1.230E-01 2.500E-01 --- TE(2)
R19B Growing Season for Fodder (years) 8.200E-02 8.000E-02 --- TE(3)
R19B Translocation Factor for Non-Leafy 1.000E-01 1.000E-01 --- TIV(1)
R19B Translocation Factor for Leafy 1.000E+00 1.000E+00 --- TIV(2)
R19B Translocation Factor for Fodder 1.000E+00 1.000E+00 --- TIV(3)
R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RDRY(1)
R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 --- RDRY(2)
R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RDRY(3)
R19B Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RWET(1)
R19B Wet Foliar Interception Fraction for Leafy 5.800E-01 2.500E-01 --- RWET(2)
R19B Wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RWET(3)
R19B Weathering Removal Constant for Vegetation 2.150E+01 2.000E+01 --- WLAM C14 C-12 concentration in water (g/cm**3) not used 2.000E-05 --- C12WTR C14 C-12 concentration in contaminated soil (g/g) not used 3.000E-02 --- C12CZ C14 Fraction of vegetation carbon from soil not used 2.000E-02 --- CSOIL C14 Fraction of vegetation carbon from air not used 9.800E-01 --- CAIR C14 C-14 evasion layer thickness in soil (m) not used 3.000E-01 --- DMC C14 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 --- EVSN C14 C-12 evasion flux rate from soil (1/sec) not used 1.000E-10 --- REVSN C14 Fraction of grain in beef cattle feed not used 8.000E-01 --- AVFG4 C14 Fraction of grain in milk cow feed not used 2.000E-01 --- AVFG5 C14 DCF correction factor for gaseous forms of C14 not used 8.894E+01 --- CO2F
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:49 Page 6 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Ni63-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 --- STOR_T(1)
STOR Leafy vegetables 1.000E+00 1.000E+00 --- STOR_T(2)
STOR Milk 1.000E+00 1.000E+00 --- STOR_T(3)
STOR Meat and poultry 2.000E+01 2.000E+01 --- STOR_T(4)
STOR Fish 7.000E+00 7.000E+00 --- STOR_T(5)
STOR Crustacea and mollusks 7.000E+00 7.000E+00 --- STOR_T(6)
STOR Well water 1.000E+00 1.000E+00 --- STOR_T(7)
STOR Surface water 1.000E+00 1.000E+00 --- STOR_T(8)
STOR Livestock fodder 4.500E+01 4.500E+01 --- STOR_T(9)
R021 Thickness of building foundation (m) not used 1.500E-01 --- FLOOR1 R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 --- DENSFL R021 Total porosity of the cover material not used 4.000E-01 --- TPCV R021 Total porosity of the building foundation not used 1.000E-01 --- TPFL R021 Volumetric water content of the cover material not used 5.000E-02 --- PH2OCV R021 Volumetric water content of the foundation not used 3.000E-02 --- PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.000E-06 --- DIFCV R021 in foundation material not used 3.000E-07 --- DIFFL R021 in contaminated zone soil not used 2.000E-06 --- DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.000E+00 --- HMIX R021 Average building air exchange rate (1/hr) not used 5.000E-01 --- REXG R021 Height of the building (room) (m) not used 2.500E+00 --- HRM R021 Building interior area factor not used 0.000E+00 --- FAI R021 Building depth below ground surface (m) not used -1.000E+00 --- DMFL R021 Emanating power of Rn-222 gas not used 2.500E-01 --- EMANA(1)
R021 Emanating power of Rn-220 gas not used 1.500E-01 --- EMANA(2)
TITL Number of graphical time points 32 --- --- NPTS TITL Maximum number of integration points for dose 17 --- --- LYMAX TITL Maximum number of integration points for risk 1 --- --- KYMAX Summary of Pathway Selections Pathway User Selection 1 -- external gamma active 2 -- inhalation (w/o radon) active 3 -- plant ingestion active 4 -- meat ingestion active 5 -- milk ingestion active 6 -- aquatic foods active 7 -- drinking water active 8 -- soil ingestion active 9 -- radon suppressed Find peak pathway doses suppressed
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:49 Page 7 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Ni63-concrete-DCGL.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area: 5020.00 square meters Ni-63 1.000E+00 Thickness: 3.80 meters Cover Depth: 0.00 meters 0
Total Dose TDOSE(t), mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years): 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 TDOSE(t): 2.285E-01 2.295E-01 2.255E-01 2.119E-01 1.773E-01 9.500E-02 1.599E-02 3.122E-05 M(t): 9.140E-03 9.182E-03 9.019E-03 8.474E-03 7.091E-03 3.800E-03 6.394E-04 1.249E-06 0Maximum TDOSE(t): 2.314E-01 mrem/yr at t = 0.1001 +/- 0.0002 years 0
Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.001E-01 years 0 Water Independent Pathways (Inhalation excludes radon) 0 Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Nuclide Ni-63 0.000E+00 0.0000 9.260E-08 0.0000 0.000E+00 0.0000 4.050E-02 0.1751 2.772E-03 0.0120 1.457E-01 0.6297 8.124E-06 0.0000 Total 0.000E+00 0.0000 9.260E-08 0.0000 0.000E+00 0.0000 4.050E-02 0.1751 2.772E-03 0.0120 1.457E-01 0.6297 8.124E-06 0.0000 0
Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.001E-01 years 0 Water Dependent Pathways 0 Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Nuclide Ni-63 7.726E-03 0.0334 2.221E-04 0.0010 0.000E+00 0.0000 2.346E-03 0.0101 7.167E-04 0.0031 3.140E-02 0.1357 2.314E-01 1.0000 Total 7.726E-03 0.0334 2.221E-04 0.0010 0.000E+00 0.0000 2.346E-03 0.0101 7.167E-04 0.0031 3.140E-02 0.1357 2.314E-01 1.0000 0*Sum of all water independent and dependent pathways.
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:13 Page 1 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Pu238-concrete-DCGL.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary ... 2 Site-Specific Parameter Summary .......................... 4 Summary of Pathway Selections ............................ 8 Contaminated Zone and Total Dose Summary ................. 9 Total Dose Components Time = 0.000E+00 .................................... 10 Time = 1.000E+00 .................................... 11 Time = 3.000E+00 .................................... 12 Time = 1.000E+01 .................................... 13 Time = 3.000E+01 .................................... 14 Time = 1.000E+02 .................................... 15 Time = 3.000E+02 .................................... 16 Time = 1.000E+03 .................................... 17 Dose/Source Ratios Summed Over All Pathways .............. 18 Single Radionuclide Soil Guidelines ...................... 18 Dose Per Nuclide Summed Over All Pathways ................ 19 Soil Concentration Per Nuclide ........................... 19
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:13 Page 2 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Pu238-concrete-DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary File: YR Concrete 0 Current Parameter Menu Parameter Value Default Name B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 Pb-210+D 2.320E-02 2.320E-02 DCF2( 1)
B-1 Pu-238 3.920E-01 3.920E-01 DCF2( 2)
B-1 Ra-226+D 8.600E-03 8.600E-03 DCF2( 3)
B-1 Th-230 3.260E-01 3.260E-01 DCF2( 4)
B-1 U-234 1.320E-01 1.320E-01 DCF2( 5)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Pb-210+D 7.270E-03 7.270E-03 DCF3( 1)
D-1 Pu-238 3.200E-03 3.200E-03 DCF3( 2)
D-1 Ra-226+D 1.330E-03 1.330E-03 DCF3( 3)
D-1 Th-230 5.480E-04 5.480E-04 DCF3( 4)
D-1 U-234 2.830E-04 2.830E-04 DCF3( 5)
D-34 Food transfer factors:
D-34 Pb-210+D , plant/soil concentration ratio, dimensionless 1.880E-07 1.000E-02 RTF( 1,1)
D-34 Pb-210+D , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 8.000E-04 8.000E-04 RTF( 1,2)
D-34 Pb-210+D , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 3.000E-04 3.000E-04 RTF( 1,3)
D-34 D-34 Pu-238 , plant/soil concentration ratio, dimensionless 8.240E-05 1.000E-03 RTF( 2,1)
D-34 Pu-238 , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.000E-04 1.000E-04 RTF( 2,2)
D-34 Pu-238 , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.000E-06 1.000E-06 RTF( 2,3)
D-34 D-34 Ra-226+D , plant/soil concentration ratio, dimensionless 4.000E-02 4.000E-02 RTF( 3,1)
D-34 Ra-226+D , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.000E-03 1.000E-03 RTF( 3,2)
D-34 Ra-226+D , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.000E-03 1.000E-03 RTF( 3,3)
D-34 D-34 Th-230 , plant/soil concentration ratio, dimensionless 8.240E-05 1.000E-03 RTF( 4,1)
D-34 Th-230 , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.000E-04 1.000E-04 RTF( 4,2)
D-34 Th-230 , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 5.000E-06 5.000E-06 RTF( 4,3)
D-34 D-34 U-234 , plant/soil concentration ratio, dimensionless 5.710E-03 2.500E-03 RTF( 5,1)
D-34 U-234 , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 8.000E-04 3.400E-04 RTF( 5,2)
D-34 U-234 , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 4.000E-04 6.000E-04 RTF( 5,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Pb-210+D , fish 3.000E+02 3.000E+02 BIOFAC( 1,1)
D-5 Pb-210+D , crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC( 1,2)
D-5 D-5 Pu-238 , fish 3.000E+01 3.000E+01 BIOFAC( 2,1)
D-5 Pu-238 , crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC( 2,2)
D-5 D-5 Ra-226+D , fish 4.900E+01 5.000E+01 BIOFAC( 3,1)
D-5 Ra-226+D , crustacea and mollusks 2.500E+02 2.500E+02 BIOFAC( 3,2)
D-5 D-5 Th-230 , fish 9.900E+01 1.000E+02 BIOFAC( 4,1)
D-5 Th-230 , crustacea and mollusks 5.000E+02 5.000E+02 BIOFAC( 4,2)
D-5
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:13 Page 3 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Pu238-concrete-DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)
File: YR Concrete 0 Current Parameter Menu Parameter Value Default Name D-5 U-234 , fish 1.000E+01 1.000E+01 BIOFAC( 5,1)
D-5 U-234 , crustacea and mollusks 6.000E+01 6.000E+01 BIOFAC( 5,2)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:13 Page 4 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Pu238-concrete-DCGL.RAD Site-Specific Parameter Summary 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R011 Area of contaminated zone (m**2) 5.020E+03 1.000E+04 --- AREA R011 Thickness of contaminated zone (m) 3.800E+00 2.000E+00 --- THICK0 R011 Length parallel to aquifer flow (m) 8.000E+01 1.000E+02 --- LCZPAQ R011 Basic radiation dose limit (mrem/yr) 2.500E+01 2.500E+01 --- BRDL R011 Time since placement of material (yr) 0.000E+00 0.000E+00 --- TI R011 Times for calculations (yr) 1.000E+00 1.000E+00 --- T( 2)
R011 Times for calculations (yr) 3.000E+00 3.000E+00 --- T( 3)
R011 Times for calculations (yr) 1.000E+01 1.000E+01 --- T( 4)
R011 Times for calculations (yr) 3.000E+01 3.000E+01 --- T( 5)
R011 Times for calculations (yr) 1.000E+02 1.000E+02 --- T( 6)
R011 Times for calculations (yr) 3.000E+02 3.000E+02 --- T( 7)
R011 Times for calculations (yr) 1.000E+03 1.000E+03 --- T( 8)
R011 Times for calculations (yr) not used 0.000E+00 --- T( 9)
R011 Times for calculations (yr) not used 0.000E+00 --- T(10)
R012 Initial principal radionuclide (pCi/g): Pu-238 1.000E+00 0.000E+00 --- S1( 2)
R012 Concentration in groundwater (pCi/L): Pu-238 not used 0.000E+00 --- W1( 2)
R013 Cover depth (m) 0.000E+00 0.000E+00 --- COVER0 R013 Density of cover material (g/cm**3) not used 1.500E+00 --- DENSCV R013 Cover depth erosion rate (m/yr) not used 1.000E-03 --- VCV R013 Density of contaminated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSCZ R013 Contaminated zone erosion rate (m/yr) 8.500E-04 1.000E-03 --- VCZ R013 Contaminated zone total porosity 3.000E-01 4.000E-01 --- TPCZ R013 Contaminated zone field capacity 7.000E-02 2.000E-01 --- FCCZ R013 Contaminated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+01 --- HCCZ R013 Contaminated zone b parameter 9.750E-01 5.300E+00 --- BCZ R013 Average annual wind speed (m/sec) 2.030E+00 2.000E+00 --- WIND R013 Humidity in air (g/m**3) not used 8.000E+00 --- HUMID R013 Evapotranspiration coefficient 6.250E-01 5.000E-01 --- EVAPTR R013 Precipitation (m/yr) 1.200E+00 1.000E+00 --- PRECIP R013 Irrigation (m/yr) 4.350E-01 2.000E-01 --- RI R013 Irrigation mode overhead overhead --- IDITCH R013 Runoff coefficient 6.000E-01 2.000E-01 --- RUNOFF R013 Watershed area for nearby stream or pond (m**2) 7.770E+05 1.000E+06 --- WAREA R013 Accuracy for water/soil computations 1.000E-03 1.000E-03 --- EPS R014 Density of saturated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSAQ R014 Saturated zone total porosity 2.800E-01 4.000E-01 --- TPSZ R014 Saturated zone effective porosity 2.100E-01 2.000E-01 --- EPSZ R014 Saturated zone field capacity 7.000E-02 2.000E-01 --- FCSZ R014 Saturated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+02 --- HCSZ R014 Saturated zone hydraulic gradient 1.000E-01 2.000E-02 --- HGWT R014 Saturated zone b parameter 9.750E-01 5.300E+00 --- BSZ R014 Water table drop rate (m/yr) 1.000E-03 1.000E-03 --- VWT R014 Well pump intake depth (m below water table) 1.000E+01 1.000E+01 --- DWIBWT R014 Model: Nondispersion (ND) or Mass-Balance (MB) MB ND --- MODEL R014 Well pumping rate (m**3/yr) 2.500E+02 2.500E+02 --- UW R015 Number of unsaturated zone strata 0 1 --- NS
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:13 Page 5 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Pu238-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R016 Distribution coefficients for Pu-238 R016 Contaminated zone (cm**3/g) 8.880E+02 2.000E+03 --- DCNUCC( 2)
R016 Saturated zone (cm**3/g) 0.000E+00 2.000E+03 --- DCNUCS( 2)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 6.603E-05 ALEACH( 2)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 2)
R016 Distribution coefficients for daughter Pb-210 R016 Contaminated zone (cm**3/g) 4.760E+04 1.000E+02 --- DCNUCC( 1)
R016 Saturated zone (cm**3/g) 0.000E+00 1.000E+02 --- DCNUCS( 1)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 1.232E-06 ALEACH( 1)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 1)
R016 Distribution coefficients for daughter Ra-226 R016 Contaminated zone (cm**3/g) 1.000E+02 7.000E+01 --- DCNUCC( 3)
R016 Saturated zone (cm**3/g) 0.000E+00 7.000E+01 --- DCNUCS( 3)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 5.861E-04 ALEACH( 3)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 3)
R016 Distribution coefficients for daughter Th-230 R016 Contaminated zone (cm**3/g) 1.580E+03 6.000E+04 --- DCNUCC( 4)
R016 Saturated zone (cm**3/g) 0.000E+00 6.000E+04 --- DCNUCS( 4)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 3.711E-05 ALEACH( 4)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 4)
R016 Distribution coefficients for daughter U-234 R016 Contaminated zone (cm**3/g) 1.470E+02 5.000E+01 --- DCNUCC( 5)
R016 Saturated zone (cm**3/g) 0.000E+00 5.000E+01 --- DCNUCS( 5)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 3.987E-04 ALEACH( 5)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 5)
R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 --- INHALR R017 Mass loading for inhalation (g/m**3) 2.330E-05 1.000E-04 --- MLINH R017 Exposure duration 3.000E+01 3.000E+01 --- ED R017 Shielding factor, inhalation 5.500E-01 4.000E-01 --- SHF3 R017 Shielding factor, external gamma 2.725E-01 7.000E-01 --- SHF1 R017 Fraction of time spent indoors 6.571E-01 5.000E-01 --- FIND R017 Fraction of time spent outdoors (on site) 1.181E-01 2.500E-01 --- FOTD R017 Shape factor flag, external gamma 1.000E+00 1.000E+00 >0 shows circular AREA. FS
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:13 Page 6 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Pu238-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R017 Radii of shape factor array (used if FS = -1):
R017 Outer annular radius (m), ring 1: not used 5.000E+01 --- RAD_SHAPE( 1)
R017 Outer annular radius (m), ring 2: not used 7.071E+01 --- RAD_SHAPE( 2)
R017 Outer annular radius (m), ring 3: not used 0.000E+00 --- RAD_SHAPE( 3)
R017 Outer annular radius (m), ring 4: not used 0.000E+00 --- RAD_SHAPE( 4)
R017 Outer annular radius (m), ring 5: not used 0.000E+00 --- RAD_SHAPE( 5)
R017 Outer annular radius (m), ring 6: not used 0.000E+00 --- RAD_SHAPE( 6)
R017 Outer annular radius (m), ring 7: not used 0.000E+00 --- RAD_SHAPE( 7)
R017 Outer annular radius (m), ring 8: not used 0.000E+00 --- RAD_SHAPE( 8)
R017 Outer annular radius (m), ring 9: not used 0.000E+00 --- RAD_SHAPE( 9)
R017 Outer annular radius (m), ring 10: not used 0.000E+00 --- RAD_SHAPE(10)
R017 Outer annular radius (m), ring 11: not used 0.000E+00 --- RAD_SHAPE(11)
R017 Outer annular radius (m), ring 12: not used 0.000E+00 --- RAD_SHAPE(12)
R017 Fractions of annular areas within AREA:
R017 Ring 1 not used 1.000E+00 --- FRACA( 1)
R017 Ring 2 not used 2.732E-01 --- FRACA( 2)
R017 Ring 3 not used 0.000E+00 --- FRACA( 3)
R017 Ring 4 not used 0.000E+00 --- FRACA( 4)
R017 Ring 5 not used 0.000E+00 --- FRACA( 5)
R017 Ring 6 not used 0.000E+00 --- FRACA( 6)
R017 Ring 7 not used 0.000E+00 --- FRACA( 7)
R017 Ring 8 not used 0.000E+00 --- FRACA( 8)
R017 Ring 9 not used 0.000E+00 --- FRACA( 9)
R017 Ring 10 not used 0.000E+00 --- FRACA(10)
R017 Ring 11 not used 0.000E+00 --- FRACA(11)
R017 Ring 12 not used 0.000E+00 --- FRACA(12)
R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 --- DIET(1)
R018 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 --- DIET(2)
R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 --- DIET(3)
R018 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 --- DIET(4)
R018 Fish consumption (kg/yr) 2.060E+01 5.400E+00 --- DIET(5)
R018 Other seafood consumption (kg/yr) 9.000E-01 9.000E-01 --- DIET(6)
R018 Soil ingestion rate (g/yr) 1.826E+01 3.650E+01 --- SOIL R018 Drinking water intake (L/yr) 4.785E+02 5.100E+02 --- DWI R018 Contamination fraction of drinking water 1.000E+00 1.000E+00 --- FDW R018 Contamination fraction of household water not used 1.000E+00 --- FHHW R018 Contamination fraction of livestock water 1.000E+00 1.000E+00 --- FLW R018 Contamination fraction of irrigation water 1.000E+00 1.000E+00 --- FIRW R018 Contamination fraction of aquatic food 1.000E+00 5.000E-01 --- FR9 R018 Contamination fraction of plant food 1.000E+00 -1 --- FPLANT R018 Contamination fraction of meat 1.000E+00 -1 --- FMEAT R018 Contamination fraction of milk 1.000E+00 -1 --- FMILK R019 Livestock fodder intake for meat (kg/day) 2.710E+01 6.800E+01 --- LFI5 R019 Livestock fodder intake for milk (kg/day) 6.320E+01 5.500E+01 --- LFI6 R019 Livestock water intake for meat (L/day) 5.060E+01 5.000E+01 --- LWI5 R019 Livestock water intake for milk (L/day) 6.000E+01 1.600E+02 --- LWI6 R019 Livestock soil intake (kg/day) 5.000E-01 5.000E-01 --- LSI
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:13 Page 7 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Pu238-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R019 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.000E-04 --- MLFD R019 Depth of soil mixing layer (m) 2.300E-01 1.500E-01 --- DM R019 Depth of roots (m) 2.050E+00 9.000E-01 --- DROOT R019 Drinking water fraction from ground water 1.000E+00 1.000E+00 --- FGWDW R019 Household water fraction from ground water not used 1.000E+00 --- FGWHH R019 Livestock water fraction from ground water 1.000E+00 1.000E+00 --- FGWLW R019 Irrigation fraction from ground water 1.000E+00 1.000E+00 --- FGWIR R19B Wet weight crop yield for Non-Leafy (kg/m**2) 1.270E+00 7.000E-01 --- YV(1)
R19B Wet weight crop yield for Leafy (kg/m**2) 2.889E+00 1.500E+00 --- YV(2)
R19B Wet weight crop yield for Fodder (kg/m**2) 1.887E+00 1.100E+00 --- YV(3)
R19B Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 --- TE(1)
R19B Growing Season for Leafy (years) 1.230E-01 2.500E-01 --- TE(2)
R19B Growing Season for Fodder (years) 8.200E-02 8.000E-02 --- TE(3)
R19B Translocation Factor for Non-Leafy 1.000E-01 1.000E-01 --- TIV(1)
R19B Translocation Factor for Leafy 1.000E+00 1.000E+00 --- TIV(2)
R19B Translocation Factor for Fodder 1.000E+00 1.000E+00 --- TIV(3)
R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RDRY(1)
R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 --- RDRY(2)
R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RDRY(3)
R19B Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RWET(1)
R19B Wet Foliar Interception Fraction for Leafy 7.000E-01 2.500E-01 --- RWET(2)
R19B Wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RWET(3)
R19B Weathering Removal Constant for Vegetation 2.150E+01 2.000E+01 --- WLAM C14 C-12 concentration in water (g/cm**3) not used 2.000E-05 --- C12WTR C14 C-12 concentration in contaminated soil (g/g) not used 3.000E-02 --- C12CZ C14 Fraction of vegetation carbon from soil not used 2.000E-02 --- CSOIL C14 Fraction of vegetation carbon from air not used 9.800E-01 --- CAIR C14 C-14 evasion layer thickness in soil (m) not used 3.000E-01 --- DMC C14 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 --- EVSN C14 C-12 evasion flux rate from soil (1/sec) not used 1.000E-10 --- REVSN C14 Fraction of grain in beef cattle feed not used 8.000E-01 --- AVFG4 C14 Fraction of grain in milk cow feed not used 2.000E-01 --- AVFG5 C14 DCF correction factor for gaseous forms of C14 not used 8.894E+01 --- CO2F STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 --- STOR_T(1)
STOR Leafy vegetables 1.000E+00 1.000E+00 --- STOR_T(2)
STOR Milk 1.000E+00 1.000E+00 --- STOR_T(3)
STOR Meat and poultry 2.000E+01 2.000E+01 --- STOR_T(4)
STOR Fish 7.000E+00 7.000E+00 --- STOR_T(5)
STOR Crustacea and mollusks 7.000E+00 7.000E+00 --- STOR_T(6)
STOR Well water 1.000E+00 1.000E+00 --- STOR_T(7)
STOR Surface water 1.000E+00 1.000E+00 --- STOR_T(8)
STOR Livestock fodder 4.500E+01 4.500E+01 --- STOR_T(9)
R021 Thickness of building foundation (m) not used 1.500E-01 --- FLOOR1 R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 --- DENSFL R021 Total porosity of the cover material not used 4.000E-01 --- TPCV
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:13 Page 8 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Pu238-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R021 Total porosity of the building foundation not used 1.000E-01 --- TPFL R021 Volumetric water content of the cover material not used 5.000E-02 --- PH2OCV R021 Volumetric water content of the foundation not used 3.000E-02 --- PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.000E-06 --- DIFCV R021 in foundation material not used 3.000E-07 --- DIFFL R021 in contaminated zone soil not used 2.000E-06 --- DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.000E+00 --- HMIX R021 Average building air exchange rate (1/hr) not used 5.000E-01 --- REXG R021 Height of the building (room) (m) not used 2.500E+00 --- HRM R021 Building interior area factor not used 0.000E+00 --- FAI R021 Building depth below ground surface (m) not used -1.000E+00 --- DMFL R021 Emanating power of Rn-222 gas not used 2.500E-01 --- EMANA(1)
R021 Emanating power of Rn-220 gas not used 1.500E-01 --- EMANA(2)
TITL Number of graphical time points 32 --- --- NPTS TITL Maximum number of integration points for dose 17 --- --- LYMAX TITL Maximum number of integration points for risk 1 --- --- KYMAX Summary of Pathway Selections Pathway User Selection 1 -- external gamma active 2 -- inhalation (w/o radon) active 3 -- plant ingestion active 4 -- meat ingestion active 5 -- milk ingestion active 6 -- aquatic foods active 7 -- drinking water active 8 -- soil ingestion active 9 -- radon suppressed Find peak pathway doses suppressed
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:13 Page 9 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Pu238-concrete-DCGL.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area: 5020.00 square meters Pu-238 1.000E+00 Thickness: 3.80 meters Cover Depth: 0.00 meters 0
Total Dose TDOSE(t), mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years): 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 TDOSE(t): 2.288E+00 2.389E+00 2.350E+00 2.219E+00 1.884E+00 1.063E+00 2.069E-01 9.788E-04 M(t): 9.152E-02 9.554E-02 9.399E-02 8.876E-02 7.537E-02 4.251E-02 8.277E-03 3.915E-05 0Maximum TDOSE(t): 2.407E+00 mrem/yr at t = 0.1182 +/- 0.0002 years 0
Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.182E-01 years 0 Water Independent Pathways (Inhalation excludes radon) 0 Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Nuclide Pu-238 4.400E-05 0.0000 5.773E-03 0.0024 0.000E+00 0.0000 3.662E-02 0.0152 1.042E-02 0.0043 3.755E-04 0.0002 4.507E-02 0.0187 Total 4.400E-05 0.0000 5.773E-03 0.0024 0.000E+00 0.0000 3.662E-02 0.0152 1.042E-02 0.0043 3.755E-04 0.0002 4.507E-02 0.0187 0
Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 1.182E-01 years 0 Water Dependent Pathways 0 Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Nuclide Pu-238 1.716E+00 0.7130 1.643E-02 0.0068 0.000E+00 0.0000 5.728E-01 0.2380 2.953E-03 0.0012 2.077E-04 0.0001 2.407E+00 1.0000 Total 1.716E+00 0.7130 1.643E-02 0.0068 0.000E+00 0.0000 5.728E-01 0.2380 2.953E-03 0.0012 2.077E-04 0.0001 2.407E+00 1.0000 0*Sum of all water independent and dependent pathways.
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:29 Page 1 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Pu239-concrete-DCGL.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary ... 2 Site-Specific Parameter Summary .......................... 3 Summary of Pathway Selections ............................ 7 Contaminated Zone and Total Dose Summary ................. 8 Total Dose Components Time = 0.000E+00 .................................... 9 Time = 1.000E+00 .................................... 10 Time = 3.000E+00 .................................... 11 Time = 1.000E+01 .................................... 12 Time = 3.000E+01 .................................... 13 Time = 1.000E+02 .................................... 14 Time = 3.000E+02 .................................... 15 Time = 1.000E+03 .................................... 16 Dose/Source Ratios Summed Over All Pathways .............. 17 Single Radionuclide Soil Guidelines ...................... 17 Dose Per Nuclide Summed Over All Pathways ................ 18 Soil Concentration Per Nuclide ........................... 18
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:29 Page 2 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Pu239-concrete-DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary File: YR Concrete 0 Current Parameter Menu Parameter Value Default Name B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 Ac-227+D 6.720E+00 6.720E+00 DCF2( 1)
B-1 Pa-231 1.280E+00 1.280E+00 DCF2( 2)
B-1 Pu-239 4.290E-01 4.290E-01 DCF2( 3)
B-1 U-235+D 1.230E-01 1.230E-01 DCF2( 4)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Ac-227+D 1.480E-02 1.480E-02 DCF3( 1)
D-1 Pa-231 1.060E-02 1.060E-02 DCF3( 2)
D-1 Pu-239 3.540E-03 3.540E-03 DCF3( 3)
D-1 U-235+D 2.670E-04 2.670E-04 DCF3( 4)
D-34 Food transfer factors:
D-34 Ac-227+D , plant/soil concentration ratio, dimensionless 1.870E-04 2.500E-03 RTF( 1,1)
D-34 Ac-227+D , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 2.000E-05 2.000E-05 RTF( 1,2)
D-34 Ac-227+D , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 2.000E-05 2.000E-05 RTF( 1,3)
D-34 D-34 Pa-231 , plant/soil concentration ratio, dimensionless 1.460E-03 1.000E-02 RTF( 2,1)
D-34 Pa-231 , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 5.000E-06 5.000E-03 RTF( 2,2)
D-34 Pa-231 , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 5.000E-06 5.000E-06 RTF( 2,3)
D-34 D-34 Pu-239 , plant/soil concentration ratio, dimensionless 8.240E-05 1.000E-03 RTF( 3,1)
D-34 Pu-239 , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.000E-04 1.000E-04 RTF( 3,2)
D-34 Pu-239 , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.000E-06 1.000E-06 RTF( 3,3)
D-34 D-34 U-235+D , plant/soil concentration ratio, dimensionless 5.710E-03 2.500E-03 RTF( 4,1)
D-34 U-235+D , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 8.000E-04 3.400E-04 RTF( 4,2)
D-34 U-235+D , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 4.000E-04 6.000E-04 RTF( 4,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Ac-227+D , fish 1.500E+01 1.500E+01 BIOFAC( 1,1)
D-5 Ac-227+D , crustacea and mollusks 1.000E+03 1.000E+03 BIOFAC( 1,2)
D-5 D-5 Pa-231 , fish 1.000E+01 1.000E+01 BIOFAC( 2,1)
D-5 Pa-231 , crustacea and mollusks 1.100E+02 1.100E+02 BIOFAC( 2,2)
D-5 D-5 Pu-239 , fish 6.290E+01 3.000E+01 BIOFAC( 3,1)
D-5 Pu-239 , crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC( 3,2)
D-5 D-5 U-235+D , fish 1.000E+01 1.000E+01 BIOFAC( 4,1)
D-5 U-235+D , crustacea and mollusks 6.000E+01 6.000E+01 BIOFAC( 4,2)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:29 Page 3 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Pu239-concrete-DCGL.RAD Site-Specific Parameter Summary 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R011 Area of contaminated zone (m**2) 5.020E+03 1.000E+04 --- AREA R011 Thickness of contaminated zone (m) 3.800E+00 2.000E+00 --- THICK0 R011 Length parallel to aquifer flow (m) 8.000E+01 1.000E+02 --- LCZPAQ R011 Basic radiation dose limit (mrem/yr) 2.500E+01 2.500E+01 --- BRDL R011 Time since placement of material (yr) 0.000E+00 0.000E+00 --- TI R011 Times for calculations (yr) 1.000E+00 1.000E+00 --- T( 2)
R011 Times for calculations (yr) 3.000E+00 3.000E+00 --- T( 3)
R011 Times for calculations (yr) 1.000E+01 1.000E+01 --- T( 4)
R011 Times for calculations (yr) 3.000E+01 3.000E+01 --- T( 5)
R011 Times for calculations (yr) 1.000E+02 1.000E+02 --- T( 6)
R011 Times for calculations (yr) 3.000E+02 3.000E+02 --- T( 7)
R011 Times for calculations (yr) 1.000E+03 1.000E+03 --- T( 8)
R011 Times for calculations (yr) not used 0.000E+00 --- T( 9)
R011 Times for calculations (yr) not used 0.000E+00 --- T(10)
R012 Initial principal radionuclide (pCi/g): Pu-239 1.000E+00 0.000E+00 --- S1( 3)
R012 Concentration in groundwater (pCi/L): Pu-239 not used 0.000E+00 --- W1( 3)
R013 Cover depth (m) 0.000E+00 0.000E+00 --- COVER0 R013 Density of cover material (g/cm**3) not used 1.500E+00 --- DENSCV R013 Cover depth erosion rate (m/yr) not used 1.000E-03 --- VCV R013 Density of contaminated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSCZ R013 Contaminated zone erosion rate (m/yr) 8.500E-04 1.000E-03 --- VCZ R013 Contaminated zone total porosity 3.000E-01 4.000E-01 --- TPCZ R013 Contaminated zone field capacity 7.000E-02 2.000E-01 --- FCCZ R013 Contaminated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+01 --- HCCZ R013 Contaminated zone b parameter 9.750E-01 5.300E+00 --- BCZ R013 Average annual wind speed (m/sec) 2.030E+00 2.000E+00 --- WIND R013 Humidity in air (g/m**3) not used 8.000E+00 --- HUMID R013 Evapotranspiration coefficient 6.250E-01 5.000E-01 --- EVAPTR R013 Precipitation (m/yr) 1.200E+00 1.000E+00 --- PRECIP R013 Irrigation (m/yr) 4.350E-01 2.000E-01 --- RI R013 Irrigation mode overhead overhead --- IDITCH R013 Runoff coefficient 6.000E-01 2.000E-01 --- RUNOFF R013 Watershed area for nearby stream or pond (m**2) 7.770E+05 1.000E+06 --- WAREA R013 Accuracy for water/soil computations 1.000E-03 1.000E-03 --- EPS R014 Density of saturated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSAQ R014 Saturated zone total porosity 2.800E-01 4.000E-01 --- TPSZ R014 Saturated zone effective porosity 2.100E-01 2.000E-01 --- EPSZ R014 Saturated zone field capacity 7.000E-02 2.000E-01 --- FCSZ R014 Saturated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+02 --- HCSZ R014 Saturated zone hydraulic gradient 1.000E-01 2.000E-02 --- HGWT R014 Saturated zone b parameter 9.750E-01 5.300E+00 --- BSZ R014 Water table drop rate (m/yr) 1.000E-03 1.000E-03 --- VWT R014 Well pump intake depth (m below water table) 1.000E+01 1.000E+01 --- DWIBWT R014 Model: Nondispersion (ND) or Mass-Balance (MB) MB ND --- MODEL R014 Well pumping rate (m**3/yr) 2.500E+02 2.500E+02 --- UW R015 Number of unsaturated zone strata 0 1 --- NS
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:29 Page 4 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Pu239-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R016 Distribution coefficients for Pu-239 R016 Contaminated zone (cm**3/g) 8.880E+02 2.000E+03 --- DCNUCC( 3)
R016 Saturated zone (cm**3/g) 0.000E+00 2.000E+03 --- DCNUCS( 3)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 6.603E-05 ALEACH( 3)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 3)
R016 Distribution coefficients for daughter Ac-227 R016 Contaminated zone (cm**3/g) 1.000E+03 2.000E+01 --- DCNUCC( 1)
R016 Saturated zone (cm**3/g) 0.000E+00 2.000E+01 --- DCNUCS( 1)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 5.863E-05 ALEACH( 1)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 1)
R016 Distribution coefficients for daughter Pa-231 R016 Contaminated zone (cm**3/g) 3.160E+02 5.000E+01 --- DCNUCC( 2)
R016 Saturated zone (cm**3/g) 0.000E+00 5.000E+01 --- DCNUCS( 2)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 1.855E-04 ALEACH( 2)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 2)
R016 Distribution coefficients for daughter U-235 R016 Contaminated zone (cm**3/g) 1.470E+02 5.000E+01 --- DCNUCC( 4)
R016 Saturated zone (cm**3/g) 0.000E+00 5.000E+01 --- DCNUCS( 4)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 3.987E-04 ALEACH( 4)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 4)
R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 --- INHALR R017 Mass loading for inhalation (g/m**3) 2.330E-05 1.000E-04 --- MLINH R017 Exposure duration 3.000E+01 3.000E+01 --- ED R017 Shielding factor, inhalation 5.500E-01 4.000E-01 --- SHF3 R017 Shielding factor, external gamma 2.725E-01 7.000E-01 --- SHF1 R017 Fraction of time spent indoors 6.571E-01 5.000E-01 --- FIND R017 Fraction of time spent outdoors (on site) 1.181E-01 2.500E-01 --- FOTD R017 Shape factor flag, external gamma 1.000E+00 1.000E+00 >0 shows circular AREA. FS R017 Radii of shape factor array (used if FS = -1):
R017 Outer annular radius (m), ring 1: not used 5.000E+01 --- RAD_SHAPE( 1)
R017 Outer annular radius (m), ring 2: not used 7.071E+01 --- RAD_SHAPE( 2)
R017 Outer annular radius (m), ring 3: not used 0.000E+00 --- RAD_SHAPE( 3)
R017 Outer annular radius (m), ring 4: not used 0.000E+00 --- RAD_SHAPE( 4)
R017 Outer annular radius (m), ring 5: not used 0.000E+00 --- RAD_SHAPE( 5)
R017 Outer annular radius (m), ring 6: not used 0.000E+00 --- RAD_SHAPE( 6)
R017 Outer annular radius (m), ring 7: not used 0.000E+00 --- RAD_SHAPE( 7)
R017 Outer annular radius (m), ring 8: not used 0.000E+00 --- RAD_SHAPE( 8)
R017 Outer annular radius (m), ring 9: not used 0.000E+00 --- RAD_SHAPE( 9)
R017 Outer annular radius (m), ring 10: not used 0.000E+00 --- RAD_SHAPE(10)
R017 Outer annular radius (m), ring 11: not used 0.000E+00 --- RAD_SHAPE(11)
R017 Outer annular radius (m), ring 12: not used 0.000E+00 --- RAD_SHAPE(12)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:29 Page 5 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Pu239-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R017 Fractions of annular areas within AREA:
R017 Ring 1 not used 1.000E+00 --- FRACA( 1)
R017 Ring 2 not used 2.732E-01 --- FRACA( 2)
R017 Ring 3 not used 0.000E+00 --- FRACA( 3)
R017 Ring 4 not used 0.000E+00 --- FRACA( 4)
R017 Ring 5 not used 0.000E+00 --- FRACA( 5)
R017 Ring 6 not used 0.000E+00 --- FRACA( 6)
R017 Ring 7 not used 0.000E+00 --- FRACA( 7)
R017 Ring 8 not used 0.000E+00 --- FRACA( 8)
R017 Ring 9 not used 0.000E+00 --- FRACA( 9)
R017 Ring 10 not used 0.000E+00 --- FRACA(10)
R017 Ring 11 not used 0.000E+00 --- FRACA(11)
R017 Ring 12 not used 0.000E+00 --- FRACA(12)
R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 --- DIET(1)
R018 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 --- DIET(2)
R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 --- DIET(3)
R018 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 --- DIET(4)
R018 Fish consumption (kg/yr) 2.060E+01 5.400E+00 --- DIET(5)
R018 Other seafood consumption (kg/yr) 9.000E-01 9.000E-01 --- DIET(6)
R018 Soil ingestion rate (g/yr) 1.826E+01 3.650E+01 --- SOIL R018 Drinking water intake (L/yr) 4.785E+02 5.100E+02 --- DWI R018 Contamination fraction of drinking water 1.000E+00 1.000E+00 --- FDW R018 Contamination fraction of household water not used 1.000E+00 --- FHHW R018 Contamination fraction of livestock water 1.000E+00 1.000E+00 --- FLW R018 Contamination fraction of irrigation water 1.000E+00 1.000E+00 --- FIRW R018 Contamination fraction of aquatic food 1.000E+00 5.000E-01 --- FR9 R018 Contamination fraction of plant food 1.000E+00 -1 --- FPLANT R018 Contamination fraction of meat 1.000E+00 -1 --- FMEAT R018 Contamination fraction of milk 1.000E+00 -1 --- FMILK R019 Livestock fodder intake for meat (kg/day) 2.710E+01 6.800E+01 --- LFI5 R019 Livestock fodder intake for milk (kg/day) 6.320E+01 5.500E+01 --- LFI6 R019 Livestock water intake for meat (L/day) 5.060E+01 5.000E+01 --- LWI5 R019 Livestock water intake for milk (L/day) 6.000E+01 1.600E+02 --- LWI6 R019 Livestock soil intake (kg/day) 5.000E-01 5.000E-01 --- LSI R019 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.000E-04 --- MLFD R019 Depth of soil mixing layer (m) 2.300E-01 1.500E-01 --- DM R019 Depth of roots (m) 2.050E+00 9.000E-01 --- DROOT R019 Drinking water fraction from ground water 1.000E+00 1.000E+00 --- FGWDW R019 Household water fraction from ground water not used 1.000E+00 --- FGWHH R019 Livestock water fraction from ground water 1.000E+00 1.000E+00 --- FGWLW R019 Irrigation fraction from ground water 1.000E+00 1.000E+00 --- FGWIR R19B Wet weight crop yield for Non-Leafy (kg/m**2) 1.270E+00 7.000E-01 --- YV(1)
R19B Wet weight crop yield for Leafy (kg/m**2) 2.889E+00 1.500E+00 --- YV(2)
R19B Wet weight crop yield for Fodder (kg/m**2) 1.887E+00 1.100E+00 --- YV(3)
R19B Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 --- TE(1)
R19B Growing Season for Leafy (years) 1.230E-01 2.500E-01 --- TE(2)
R19B Growing Season for Fodder (years) 8.200E-02 8.000E-02 --- TE(3)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:29 Page 6 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Pu239-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R19B Translocation Factor for Non-Leafy 1.000E-01 1.000E-01 --- TIV(1)
R19B Translocation Factor for Leafy 1.000E+00 1.000E+00 --- TIV(2)
R19B Translocation Factor for Fodder 1.000E+00 1.000E+00 --- TIV(3)
R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RDRY(1)
R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 --- RDRY(2)
R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RDRY(3)
R19B Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RWET(1)
R19B Wet Foliar Interception Fraction for Leafy 7.000E-01 2.500E-01 --- RWET(2)
R19B Wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RWET(3)
R19B Weathering Removal Constant for Vegetation 2.150E+01 2.000E+01 --- WLAM C14 C-12 concentration in water (g/cm**3) not used 2.000E-05 --- C12WTR C14 C-12 concentration in contaminated soil (g/g) not used 3.000E-02 --- C12CZ C14 Fraction of vegetation carbon from soil not used 2.000E-02 --- CSOIL C14 Fraction of vegetation carbon from air not used 9.800E-01 --- CAIR C14 C-14 evasion layer thickness in soil (m) not used 3.000E-01 --- DMC C14 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 --- EVSN C14 C-12 evasion flux rate from soil (1/sec) not used 1.000E-10 --- REVSN C14 Fraction of grain in beef cattle feed not used 8.000E-01 --- AVFG4 C14 Fraction of grain in milk cow feed not used 2.000E-01 --- AVFG5 C14 DCF correction factor for gaseous forms of C14 not used 8.894E+01 --- CO2F STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 --- STOR_T(1)
STOR Leafy vegetables 1.000E+00 1.000E+00 --- STOR_T(2)
STOR Milk 1.000E+00 1.000E+00 --- STOR_T(3)
STOR Meat and poultry 2.000E+01 2.000E+01 --- STOR_T(4)
STOR Fish 7.000E+00 7.000E+00 --- STOR_T(5)
STOR Crustacea and mollusks 7.000E+00 7.000E+00 --- STOR_T(6)
STOR Well water 1.000E+00 1.000E+00 --- STOR_T(7)
STOR Surface water 1.000E+00 1.000E+00 --- STOR_T(8)
STOR Livestock fodder 4.500E+01 4.500E+01 --- STOR_T(9)
R021 Thickness of building foundation (m) not used 1.500E-01 --- FLOOR1 R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 --- DENSFL R021 Total porosity of the cover material not used 4.000E-01 --- TPCV R021 Total porosity of the building foundation not used 1.000E-01 --- TPFL R021 Volumetric water content of the cover material not used 5.000E-02 --- PH2OCV R021 Volumetric water content of the foundation not used 3.000E-02 --- PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.000E-06 --- DIFCV R021 in foundation material not used 3.000E-07 --- DIFFL R021 in contaminated zone soil not used 2.000E-06 --- DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.000E+00 --- HMIX R021 Average building air exchange rate (1/hr) not used 5.000E-01 --- REXG R021 Height of the building (room) (m) not used 2.500E+00 --- HRM R021 Building interior area factor not used 0.000E+00 --- FAI R021 Building depth below ground surface (m) not used -1.000E+00 --- DMFL R021 Emanating power of Rn-222 gas not used 2.500E-01 --- EMANA(1)
R021 Emanating power of Rn-220 gas not used 1.500E-01 --- EMANA(2)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:29 Page 7 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Pu239-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name TITL Number of graphical time points 32 --- --- NPTS TITL Maximum number of integration points for dose 17 --- --- LYMAX TITL Maximum number of integration points for risk 1 --- --- KYMAX Summary of Pathway Selections Pathway User Selection 1 -- external gamma active 2 -- inhalation (w/o radon) active 3 -- plant ingestion active 4 -- meat ingestion active 5 -- milk ingestion active 6 -- aquatic foods active 7 -- drinking water active 8 -- soil ingestion active 9 -- radon suppressed Find peak pathway doses suppressed
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:29 Page 8 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Pu239-concrete-DCGL.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area: 5020.00 square meters Pu-239 1.000E+00 Thickness: 3.80 meters Cover Depth: 0.00 meters 0
Total Dose TDOSE(t), mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years): 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 TDOSE(t): 2.558E+00 2.691E+00 2.689E+00 2.684E+00 2.667E+00 2.609E+00 2.448E+00 1.923E+00 M(t): 1.023E-01 1.076E-01 1.076E-01 1.073E-01 1.067E-01 1.044E-01 9.792E-02 7.692E-02 0Maximum TDOSE(t): 2.692E+00 mrem/yr at t = 0.2811 +/- 0.0006 years 0
Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 2.811E-01 years 0 Water Independent Pathways (Inhalation excludes radon) 0 Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Nuclide Pu-239 8.326E-05 0.0000 6.349E-03 0.0024 0.000E+00 0.0000 4.071E-02 0.0151 1.158E-02 0.0043 4.174E-04 0.0002 5.011E-02 0.0186 Total 8.326E-05 0.0000 6.349E-03 0.0024 0.000E+00 0.0000 4.071E-02 0.0151 1.158E-02 0.0043 4.174E-04 0.0002 5.011E-02 0.0186 0
Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 2.811E-01 years 0 Water Dependent Pathways 0 Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Nuclide Pu-239 1.907E+00 0.7085 3.568E-02 0.0133 0.000E+00 0.0000 6.360E-01 0.2363 3.499E-03 0.0013 2.382E-04 0.0001 2.692E+00 1.0000 Total 1.907E+00 0.7085 3.568E-02 0.0133 0.000E+00 0.0000 6.360E-01 0.2363 3.499E-03 0.0013 2.382E-04 0.0001 2.692E+00 1.0000 0*Sum of all water independent and dependent pathways.
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:24 Page 1 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Pu241-concrete-DCGL.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary ... 2 Site-Specific Parameter Summary .......................... 4 Summary of Pathway Selections ............................ 8 Contaminated Zone and Total Dose Summary ................. 9 Total Dose Components Time = 0.000E+00 .................................... 10 Time = 1.000E+00 .................................... 11 Time = 3.000E+00 .................................... 12 Time = 1.000E+01 .................................... 13 Time = 3.000E+01 .................................... 14 Time = 1.000E+02 .................................... 15 Time = 3.000E+02 .................................... 16 Time = 1.000E+03 .................................... 17 Dose/Source Ratios Summed Over All Pathways .............. 18 Single Radionuclide Soil Guidelines ...................... 18 Dose Per Nuclide Summed Over All Pathways ................ 19 Soil Concentration Per Nuclide ........................... 19
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:24 Page 2 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Pu241-concrete-DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary File: YR Concrete 0 Current Parameter Menu Parameter Value Default Name B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 Am-241 4.440E-01 4.440E-01 DCF2( 1)
B-1 Np-237+D 5.400E-01 5.400E-01 DCF2( 2)
B-1 Pu-241+D 8.250E-03 8.250E-03 DCF2( 3)
B-1 Th-229+D 2.160E+00 2.160E+00 DCF2( 5)
B-1 U-233 1.350E-01 1.350E-01 DCF2( 6)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Am-241 3.640E-03 3.640E-03 DCF3( 1)
D-1 Np-237+D 4.440E-03 4.440E-03 DCF3( 2)
D-1 Pu-241+D 6.850E-05 6.850E-05 DCF3( 3)
D-1 Th-229+D 4.030E-03 4.030E-03 DCF3( 5)
D-1 U-233 2.890E-04 2.890E-04 DCF3( 6)
D-34 Food transfer factors:
D-34 Am-241 , plant/soil concentration ratio, dimensionless 7.860E-04 1.000E-03 RTF( 1,1)
D-34 Am-241 , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 5.000E-05 5.000E-05 RTF( 1,2)
D-34 Am-241 , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 2.000E-06 2.000E-06 RTF( 1,3)
D-34 D-34 Np-237+D , plant/soil concentration ratio, dimensionless 3.470E-04 2.000E-02 RTF( 2,1)
D-34 Np-237+D , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.000E-03 1.000E-03 RTF( 2,2)
D-34 Np-237+D , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.000E-05 5.000E-06 RTF( 2,3)
D-34 D-34 Pu-241+D , plant/soil concentration ratio, dimensionless 8.240E-05 1.000E-03 RTF( 3,1)
D-34 Pu-241+D , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.000E-04 1.000E-04 RTF( 3,2)
D-34 Pu-241+D , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.000E-06 1.000E-06 RTF( 3,3)
D-34 D-34 Th-229+D , plant/soil concentration ratio, dimensionless 8.240E-05 1.000E-03 RTF( 5,1)
D-34 Th-229+D , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.000E-04 1.000E-04 RTF( 5,2)
D-34 Th-229+D , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 5.000E-06 5.000E-06 RTF( 5,3)
D-34 D-34 U-233 , plant/soil concentration ratio, dimensionless 5.710E-03 2.500E-03 RTF( 6,1)
D-34 U-233 , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 8.000E-04 3.400E-04 RTF( 6,2)
D-34 U-233 , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 4.000E-04 6.000E-04 RTF( 6,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Am-241 , fish 6.290E+01 3.000E+01 BIOFAC( 1,1)
D-5 Am-241 , crustacea and mollusks 1.000E+03 1.000E+03 BIOFAC( 1,2)
D-5 D-5 Np-237+D , fish 3.000E+01 3.000E+01 BIOFAC( 2,1)
D-5 Np-237+D , crustacea and mollusks 4.000E+02 4.000E+02 BIOFAC( 2,2)
D-5 D-5 Pu-241+D , fish 3.000E+01 3.000E+01 BIOFAC( 3,1)
D-5 Pu-241+D , crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC( 3,2)
D-5 D-5 Th-229+D , fish 9.900E+01 1.000E+02 BIOFAC( 5,1)
D-5 Th-229+D , crustacea and mollusks 5.000E+02 5.000E+02 BIOFAC( 5,2)
D-5
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:24 Page 3 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Pu241-concrete-DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary (continued)
File: YR Concrete 0 Current Parameter Menu Parameter Value Default Name D-5 U-233 , fish 1.000E+01 1.000E+01 BIOFAC( 6,1)
D-5 U-233 , crustacea and mollusks 6.000E+01 6.000E+01 BIOFAC( 6,2)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:24 Page 4 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Pu241-concrete-DCGL.RAD Site-Specific Parameter Summary 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R011 Area of contaminated zone (m**2) 5.020E+03 1.000E+04 --- AREA R011 Thickness of contaminated zone (m) 3.800E+00 2.000E+00 --- THICK0 R011 Length parallel to aquifer flow (m) 8.000E+01 1.000E+02 --- LCZPAQ R011 Basic radiation dose limit (mrem/yr) 2.500E+01 2.500E+01 --- BRDL R011 Time since placement of material (yr) 0.000E+00 0.000E+00 --- TI R011 Times for calculations (yr) 1.000E+00 1.000E+00 --- T( 2)
R011 Times for calculations (yr) 3.000E+00 3.000E+00 --- T( 3)
R011 Times for calculations (yr) 1.000E+01 1.000E+01 --- T( 4)
R011 Times for calculations (yr) 3.000E+01 3.000E+01 --- T( 5)
R011 Times for calculations (yr) 1.000E+02 1.000E+02 --- T( 6)
R011 Times for calculations (yr) 3.000E+02 3.000E+02 --- T( 7)
R011 Times for calculations (yr) 1.000E+03 1.000E+03 --- T( 8)
R011 Times for calculations (yr) not used 0.000E+00 --- T( 9)
R011 Times for calculations (yr) not used 0.000E+00 --- T(10)
R012 Initial principal radionuclide (pCi/g): Pu-241 1.000E+00 0.000E+00 --- S1( 3)
R012 Concentration in groundwater (pCi/L): Pu-241 not used 0.000E+00 --- W1( 3)
R013 Cover depth (m) 0.000E+00 0.000E+00 --- COVER0 R013 Density of cover material (g/cm**3) not used 1.500E+00 --- DENSCV R013 Cover depth erosion rate (m/yr) not used 1.000E-03 --- VCV R013 Density of contaminated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSCZ R013 Contaminated zone erosion rate (m/yr) 8.500E-04 1.000E-03 --- VCZ R013 Contaminated zone total porosity 3.000E-01 4.000E-01 --- TPCZ R013 Contaminated zone field capacity 7.000E-02 2.000E-01 --- FCCZ R013 Contaminated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+01 --- HCCZ R013 Contaminated zone b parameter 9.750E-01 5.300E+00 --- BCZ R013 Average annual wind speed (m/sec) 2.030E+00 2.000E+00 --- WIND R013 Humidity in air (g/m**3) not used 8.000E+00 --- HUMID R013 Evapotranspiration coefficient 6.250E-01 5.000E-01 --- EVAPTR R013 Precipitation (m/yr) 1.200E+00 1.000E+00 --- PRECIP R013 Irrigation (m/yr) 4.350E-01 2.000E-01 --- RI R013 Irrigation mode overhead overhead --- IDITCH R013 Runoff coefficient 6.000E-01 2.000E-01 --- RUNOFF R013 Watershed area for nearby stream or pond (m**2) 7.770E+05 1.000E+06 --- WAREA R013 Accuracy for water/soil computations 1.000E-03 1.000E-03 --- EPS R014 Density of saturated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSAQ R014 Saturated zone total porosity 2.800E-01 4.000E-01 --- TPSZ R014 Saturated zone effective porosity 2.100E-01 2.000E-01 --- EPSZ R014 Saturated zone field capacity 7.000E-02 2.000E-01 --- FCSZ R014 Saturated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+02 --- HCSZ R014 Saturated zone hydraulic gradient 1.000E-01 2.000E-02 --- HGWT R014 Saturated zone b parameter 9.750E-01 5.300E+00 --- BSZ R014 Water table drop rate (m/yr) 1.000E-03 1.000E-03 --- VWT R014 Well pump intake depth (m below water table) 1.000E+01 1.000E+01 --- DWIBWT R014 Model: Nondispersion (ND) or Mass-Balance (MB) MB ND --- MODEL R014 Well pumping rate (m**3/yr) 2.500E+02 2.500E+02 --- UW R015 Number of unsaturated zone strata 0 1 --- NS
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:24 Page 5 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Pu241-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R016 Distribution coefficients for Pu-241 R016 Contaminated zone (cm**3/g) 1.580E+03 2.000E+03 --- DCNUCC( 3)
R016 Saturated zone (cm**3/g) 0.000E+00 2.000E+03 --- DCNUCS( 3)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 3.711E-05 ALEACH( 3)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 3)
R016 Distribution coefficients for daughter Am-241 R016 Contaminated zone (cm**3/g) 4.470E+02 2.000E+01 --- DCNUCC( 1)
R016 Saturated zone (cm**3/g) 0.000E+00 2.000E+01 --- DCNUCS( 1)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 1.312E-04 ALEACH( 1)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 1)
R016 Distribution coefficients for daughter Np-237 R016 Contaminated zone (cm**3/g) 7.070E+02 -1.000E+00 --- DCNUCC( 2)
R016 Saturated zone (cm**3/g) 0.000E+00 -1.000E+00 --- DCNUCS( 2)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 8.293E-05 ALEACH( 2)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 2)
R016 Distribution coefficients for daughter Th-229 R016 Contaminated zone (cm**3/g) 1.580E+03 6.000E+04 --- DCNUCC( 5)
R016 Saturated zone (cm**3/g) 0.000E+00 6.000E+04 --- DCNUCS( 5)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 3.711E-05 ALEACH( 5)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 5)
R016 Distribution coefficients for daughter U-233 R016 Contaminated zone (cm**3/g) 1.470E+02 5.000E+01 --- DCNUCC( 6)
R016 Saturated zone (cm**3/g) 0.000E+00 5.000E+01 --- DCNUCS( 6)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 3.987E-04 ALEACH( 6)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 6)
R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 --- INHALR R017 Mass loading for inhalation (g/m**3) 2.330E-05 1.000E-04 --- MLINH R017 Exposure duration 3.000E+01 3.000E+01 --- ED R017 Shielding factor, inhalation 5.500E-01 4.000E-01 --- SHF3 R017 Shielding factor, external gamma 2.725E-01 7.000E-01 --- SHF1 R017 Fraction of time spent indoors 6.571E-01 5.000E-01 --- FIND R017 Fraction of time spent outdoors (on site) 1.181E-01 2.500E-01 --- FOTD R017 Shape factor flag, external gamma 1.000E+00 1.000E+00 >0 shows circular AREA. FS
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:24 Page 6 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Pu241-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R017 Radii of shape factor array (used if FS = -1):
R017 Outer annular radius (m), ring 1: not used 5.000E+01 --- RAD_SHAPE( 1)
R017 Outer annular radius (m), ring 2: not used 7.071E+01 --- RAD_SHAPE( 2)
R017 Outer annular radius (m), ring 3: not used 0.000E+00 --- RAD_SHAPE( 3)
R017 Outer annular radius (m), ring 4: not used 0.000E+00 --- RAD_SHAPE( 4)
R017 Outer annular radius (m), ring 5: not used 0.000E+00 --- RAD_SHAPE( 5)
R017 Outer annular radius (m), ring 6: not used 0.000E+00 --- RAD_SHAPE( 6)
R017 Outer annular radius (m), ring 7: not used 0.000E+00 --- RAD_SHAPE( 7)
R017 Outer annular radius (m), ring 8: not used 0.000E+00 --- RAD_SHAPE( 8)
R017 Outer annular radius (m), ring 9: not used 0.000E+00 --- RAD_SHAPE( 9)
R017 Outer annular radius (m), ring 10: not used 0.000E+00 --- RAD_SHAPE(10)
R017 Outer annular radius (m), ring 11: not used 0.000E+00 --- RAD_SHAPE(11)
R017 Outer annular radius (m), ring 12: not used 0.000E+00 --- RAD_SHAPE(12)
R017 Fractions of annular areas within AREA:
R017 Ring 1 not used 1.000E+00 --- FRACA( 1)
R017 Ring 2 not used 2.732E-01 --- FRACA( 2)
R017 Ring 3 not used 0.000E+00 --- FRACA( 3)
R017 Ring 4 not used 0.000E+00 --- FRACA( 4)
R017 Ring 5 not used 0.000E+00 --- FRACA( 5)
R017 Ring 6 not used 0.000E+00 --- FRACA( 6)
R017 Ring 7 not used 0.000E+00 --- FRACA( 7)
R017 Ring 8 not used 0.000E+00 --- FRACA( 8)
R017 Ring 9 not used 0.000E+00 --- FRACA( 9)
R017 Ring 10 not used 0.000E+00 --- FRACA(10)
R017 Ring 11 not used 0.000E+00 --- FRACA(11)
R017 Ring 12 not used 0.000E+00 --- FRACA(12)
R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 --- DIET(1)
R018 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 --- DIET(2)
R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 --- DIET(3)
R018 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 --- DIET(4)
R018 Fish consumption (kg/yr) 2.060E+01 5.400E+00 --- DIET(5)
R018 Other seafood consumption (kg/yr) 9.000E-01 9.000E-01 --- DIET(6)
R018 Soil ingestion rate (g/yr) 1.826E+01 3.650E+01 --- SOIL R018 Drinking water intake (L/yr) 4.785E+02 5.100E+02 --- DWI R018 Contamination fraction of drinking water 1.000E+00 1.000E+00 --- FDW R018 Contamination fraction of household water not used 1.000E+00 --- FHHW R018 Contamination fraction of livestock water 1.000E+00 1.000E+00 --- FLW R018 Contamination fraction of irrigation water 1.000E+00 1.000E+00 --- FIRW R018 Contamination fraction of aquatic food 1.000E+00 5.000E-01 --- FR9 R018 Contamination fraction of plant food 1.000E+00 -1 --- FPLANT R018 Contamination fraction of meat 1.000E+00 -1 --- FMEAT R018 Contamination fraction of milk 1.000E+00 -1 --- FMILK R019 Livestock fodder intake for meat (kg/day) 2.710E+01 6.800E+01 --- LFI5 R019 Livestock fodder intake for milk (kg/day) 6.320E+01 5.500E+01 --- LFI6 R019 Livestock water intake for meat (L/day) 5.060E+01 5.000E+01 --- LWI5 R019 Livestock water intake for milk (L/day) 6.000E+01 1.600E+02 --- LWI6 R019 Livestock soil intake (kg/day) 5.000E-01 5.000E-01 --- LSI
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:24 Page 7 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Pu241-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R019 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.000E-04 --- MLFD R019 Depth of soil mixing layer (m) 2.300E-01 1.500E-01 --- DM R019 Depth of roots (m) 2.050E+00 9.000E-01 --- DROOT R019 Drinking water fraction from ground water 1.000E+00 1.000E+00 --- FGWDW R019 Household water fraction from ground water not used 1.000E+00 --- FGWHH R019 Livestock water fraction from ground water 1.000E+00 1.000E+00 --- FGWLW R019 Irrigation fraction from ground water 1.000E+00 1.000E+00 --- FGWIR R19B Wet weight crop yield for Non-Leafy (kg/m**2) 1.270E+00 7.000E-01 --- YV(1)
R19B Wet weight crop yield for Leafy (kg/m**2) 2.889E+00 1.500E+00 --- YV(2)
R19B Wet weight crop yield for Fodder (kg/m**2) 1.887E+00 1.100E+00 --- YV(3)
R19B Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 --- TE(1)
R19B Growing Season for Leafy (years) 1.230E-01 2.500E-01 --- TE(2)
R19B Growing Season for Fodder (years) 8.200E-02 8.000E-02 --- TE(3)
R19B Translocation Factor for Non-Leafy 1.000E-01 1.000E-01 --- TIV(1)
R19B Translocation Factor for Leafy 1.000E+00 1.000E+00 --- TIV(2)
R19B Translocation Factor for Fodder 1.000E+00 1.000E+00 --- TIV(3)
R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RDRY(1)
R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 --- RDRY(2)
R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RDRY(3)
R19B Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RWET(1)
R19B Wet Foliar Interception Fraction for Leafy 7.000E-01 2.500E-01 --- RWET(2)
R19B Wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RWET(3)
R19B Weathering Removal Constant for Vegetation 2.150E+01 2.000E+01 --- WLAM C14 C-12 concentration in water (g/cm**3) not used 2.000E-05 --- C12WTR C14 C-12 concentration in contaminated soil (g/g) not used 3.000E-02 --- C12CZ C14 Fraction of vegetation carbon from soil not used 2.000E-02 --- CSOIL C14 Fraction of vegetation carbon from air not used 9.800E-01 --- CAIR C14 C-14 evasion layer thickness in soil (m) not used 3.000E-01 --- DMC C14 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 --- EVSN C14 C-12 evasion flux rate from soil (1/sec) not used 1.000E-10 --- REVSN C14 Fraction of grain in beef cattle feed not used 8.000E-01 --- AVFG4 C14 Fraction of grain in milk cow feed not used 2.000E-01 --- AVFG5 C14 DCF correction factor for gaseous forms of C14 not used 8.894E+01 --- CO2F STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 --- STOR_T(1)
STOR Leafy vegetables 1.000E+00 1.000E+00 --- STOR_T(2)
STOR Milk 1.000E+00 1.000E+00 --- STOR_T(3)
STOR Meat and poultry 2.000E+01 2.000E+01 --- STOR_T(4)
STOR Fish 7.000E+00 7.000E+00 --- STOR_T(5)
STOR Crustacea and mollusks 7.000E+00 7.000E+00 --- STOR_T(6)
STOR Well water 1.000E+00 1.000E+00 --- STOR_T(7)
STOR Surface water 1.000E+00 1.000E+00 --- STOR_T(8)
STOR Livestock fodder 4.500E+01 4.500E+01 --- STOR_T(9)
R021 Thickness of building foundation (m) not used 1.500E-01 --- FLOOR1 R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 --- DENSFL R021 Total porosity of the cover material not used 4.000E-01 --- TPCV
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:24 Page 8 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Pu241-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R021 Total porosity of the building foundation not used 1.000E-01 --- TPFL R021 Volumetric water content of the cover material not used 5.000E-02 --- PH2OCV R021 Volumetric water content of the foundation not used 3.000E-02 --- PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.000E-06 --- DIFCV R021 in foundation material not used 3.000E-07 --- DIFFL R021 in contaminated zone soil not used 2.000E-06 --- DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.000E+00 --- HMIX R021 Average building air exchange rate (1/hr) not used 5.000E-01 --- REXG R021 Height of the building (room) (m) not used 2.500E+00 --- HRM R021 Building interior area factor not used 0.000E+00 --- FAI R021 Building depth below ground surface (m) not used -1.000E+00 --- DMFL R021 Emanating power of Rn-222 gas not used 2.500E-01 --- EMANA(1)
R021 Emanating power of Rn-220 gas not used 1.500E-01 --- EMANA(2)
TITL Number of graphical time points 32 --- --- NPTS TITL Maximum number of integration points for dose 17 --- --- LYMAX TITL Maximum number of integration points for risk 1 --- --- KYMAX Summary of Pathway Selections Pathway User Selection 1 -- external gamma active 2 -- inhalation (w/o radon) active 3 -- plant ingestion active 4 -- meat ingestion active 5 -- milk ingestion active 6 -- aquatic foods active 7 -- drinking water active 8 -- soil ingestion active 9 -- radon suppressed Find peak pathway doses suppressed
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:24 Page 9 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Pu241-concrete-DCGL.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area: 5020.00 square meters Pu-241 1.000E+00 Thickness: 3.80 meters Cover Depth: 0.00 meters 0
Total Dose TDOSE(t), mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years): 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 TDOSE(t): 3.207E-02 4.094E-02 5.474E-02 9.326E-02 1.492E-01 1.628E-01 1.111E-01 2.795E-02 M(t): 1.283E-03 1.638E-03 2.190E-03 3.731E-03 5.968E-03 6.513E-03 4.446E-03 1.118E-03 0Maximum TDOSE(t): 1.685E-01 mrem/yr at t = 65.3 +/- 0.1 years 0
Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 6.534E+01 years 0 Water Independent Pathways (Inhalation excludes radon) 0 Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Nuclide Pu-241 3.647E-04 0.0022 1.981E-04 0.0012 0.000E+00 0.0000 1.129E-02 0.0670 1.910E-04 0.0011 2.776E-05 0.0002 1.553E-03 0.0092 Total 3.647E-04 0.0022 1.981E-04 0.0012 0.000E+00 0.0000 1.129E-02 0.0670 1.910E-04 0.0011 2.776E-05 0.0002 1.553E-03 0.0092 0
Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 6.534E+01 years 0 Water Dependent Pathways 0 Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Nuclide Pu-241 1.136E-01 0.6738 3.349E-03 0.0199 0.000E+00 0.0000 3.788E-02 0.2247 1.050E-04 0.0006 2.826E-05 0.0002 1.685E-01 1.0000 Total 1.136E-01 0.6738 3.349E-03 0.0199 0.000E+00 0.0000 3.788E-02 0.2247 1.050E-04 0.0006 2.826E-05 0.0002 1.685E-01 1.0000 0*Sum of all water independent and dependent pathways.
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:53 Page 1 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : SB125-concrete-DCGL.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary ... 2 Site-Specific Parameter Summary .......................... 3 Summary of Pathway Selections ............................ 6 Contaminated Zone and Total Dose Summary ................. 7 Total Dose Components Time = 0.000E+00 .................................... 8 Time = 1.000E+00 .................................... 9 Time = 3.000E+00 .................................... 10 Time = 1.000E+01 .................................... 11 Time = 3.000E+01 .................................... 12 Time = 1.000E+02 .................................... 13 Time = 3.000E+02 .................................... 14 Time = 1.000E+03 .................................... 15 Dose/Source Ratios Summed Over All Pathways .............. 16 Single Radionuclide Soil Guidelines ...................... 16 Dose Per Nuclide Summed Over All Pathways ................ 17 Soil Concentration Per Nuclide ........................... 17
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:53 Page 2 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : SB125-concrete-DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary File: YR Concrete 0 Current Parameter Menu Parameter Value Default Name B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 Sb-125+D 1.386E-05 1.386E-05 DCF2( 1)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Sb-125+D 3.647E-06 3.647E-06 DCF3( 1)
D-34 Food transfer factors:
D-34 Sb-125+D , plant/soil concentration ratio, dimensionless 8.500E-05 1.000E-02 RTF( 1,1)
D-34 Sb-125+D , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.000E-03 1.000E-03 RTF( 1,2)
D-34 Sb-125+D , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 6.000E-05 1.000E-04 RTF( 1,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Sb-125+D , fish 9.900E+01 1.000E+02 BIOFAC( 1,1)
D-5 Sb-125+D , crustacea and mollusks 1.000E+01 1.000E+01 BIOFAC( 1,2)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:53 Page 3 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : SB125-concrete-DCGL.RAD Site-Specific Parameter Summary 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R011 Area of contaminated zone (m**2) 5.020E+03 1.000E+04 --- AREA R011 Thickness of contaminated zone (m) 3.800E+00 2.000E+00 --- THICK0 R011 Length parallel to aquifer flow (m) 8.000E+01 1.000E+02 --- LCZPAQ R011 Basic radiation dose limit (mrem/yr) 2.500E+01 2.500E+01 --- BRDL R011 Time since placement of material (yr) 0.000E+00 0.000E+00 --- TI R011 Times for calculations (yr) 1.000E+00 1.000E+00 --- T( 2)
R011 Times for calculations (yr) 3.000E+00 3.000E+00 --- T( 3)
R011 Times for calculations (yr) 1.000E+01 1.000E+01 --- T( 4)
R011 Times for calculations (yr) 3.000E+01 3.000E+01 --- T( 5)
R011 Times for calculations (yr) 1.000E+02 1.000E+02 --- T( 6)
R011 Times for calculations (yr) 3.000E+02 3.000E+02 --- T( 7)
R011 Times for calculations (yr) 1.000E+03 1.000E+03 --- T( 8)
R011 Times for calculations (yr) not used 0.000E+00 --- T( 9)
R011 Times for calculations (yr) not used 0.000E+00 --- T(10)
R012 Initial principal radionuclide (pCi/g): Sb-125 1.000E+00 0.000E+00 --- S1( 1)
R012 Concentration in groundwater (pCi/L): Sb-125 not used 0.000E+00 --- W1( 1)
R013 Cover depth (m) 0.000E+00 0.000E+00 --- COVER0 R013 Density of cover material (g/cm**3) not used 1.500E+00 --- DENSCV R013 Cover depth erosion rate (m/yr) not used 1.000E-03 --- VCV R013 Density of contaminated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSCZ R013 Contaminated zone erosion rate (m/yr) 8.500E-04 1.000E-03 --- VCZ R013 Contaminated zone total porosity 3.000E-01 4.000E-01 --- TPCZ R013 Contaminated zone field capacity 7.000E-02 2.000E-01 --- FCCZ R013 Contaminated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+01 --- HCCZ R013 Contaminated zone b parameter 9.750E-01 5.300E+00 --- BCZ R013 Average annual wind speed (m/sec) 2.030E+00 2.000E+00 --- WIND R013 Humidity in air (g/m**3) not used 8.000E+00 --- HUMID R013 Evapotranspiration coefficient 6.250E-01 5.000E-01 --- EVAPTR R013 Precipitation (m/yr) 1.200E+00 1.000E+00 --- PRECIP R013 Irrigation (m/yr) 4.350E-01 2.000E-01 --- RI R013 Irrigation mode overhead overhead --- IDITCH R013 Runoff coefficient 6.000E-01 2.000E-01 --- RUNOFF R013 Watershed area for nearby stream or pond (m**2) 7.770E+05 1.000E+06 --- WAREA R013 Accuracy for water/soil computations 1.000E-03 1.000E-03 --- EPS R014 Density of saturated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSAQ R014 Saturated zone total porosity 2.800E-01 4.000E-01 --- TPSZ R014 Saturated zone effective porosity 2.100E-01 2.000E-01 --- EPSZ R014 Saturated zone field capacity 7.000E-02 2.000E-01 --- FCSZ R014 Saturated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+02 --- HCSZ R014 Saturated zone hydraulic gradient 1.000E-01 2.000E-02 --- HGWT R014 Saturated zone b parameter 9.750E-01 5.300E+00 --- BSZ R014 Water table drop rate (m/yr) 1.000E-03 1.000E-03 --- VWT R014 Well pump intake depth (m below water table) 1.000E+01 1.000E+01 --- DWIBWT R014 Model: Nondispersion (ND) or Mass-Balance (MB) MB ND --- MODEL R014 Well pumping rate (m**3/yr) 2.500E+02 2.500E+02 --- UW R015 Number of unsaturated zone strata 0 1 --- NS
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:53 Page 4 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : SB125-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R016 Distribution coefficients for Sb-125 R016 Contaminated zone (cm**3/g) 1.550E+03 0.000E+00 --- DCNUCC( 1)
R016 Saturated zone (cm**3/g) 0.000E+00 0.000E+00 --- DCNUCS( 1)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 3.783E-05 ALEACH( 1)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 1)
R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 --- INHALR R017 Mass loading for inhalation (g/m**3) 2.330E-05 1.000E-04 --- MLINH R017 Exposure duration 3.000E+01 3.000E+01 --- ED R017 Shielding factor, inhalation 5.500E-01 4.000E-01 --- SHF3 R017 Shielding factor, external gamma 3.980E-01 7.000E-01 --- SHF1 R017 Fraction of time spent indoors 6.571E-01 5.000E-01 --- FIND R017 Fraction of time spent outdoors (on site) 1.181E-01 2.500E-01 --- FOTD R017 Shape factor flag, external gamma 1.000E+00 1.000E+00 >0 shows circular AREA. FS R017 Radii of shape factor array (used if FS = -1):
R017 Outer annular radius (m), ring 1: not used 5.000E+01 --- RAD_SHAPE( 1)
R017 Outer annular radius (m), ring 2: not used 7.071E+01 --- RAD_SHAPE( 2)
R017 Outer annular radius (m), ring 3: not used 0.000E+00 --- RAD_SHAPE( 3)
R017 Outer annular radius (m), ring 4: not used 0.000E+00 --- RAD_SHAPE( 4)
R017 Outer annular radius (m), ring 5: not used 0.000E+00 --- RAD_SHAPE( 5)
R017 Outer annular radius (m), ring 6: not used 0.000E+00 --- RAD_SHAPE( 6)
R017 Outer annular radius (m), ring 7: not used 0.000E+00 --- RAD_SHAPE( 7)
R017 Outer annular radius (m), ring 8: not used 0.000E+00 --- RAD_SHAPE( 8)
R017 Outer annular radius (m), ring 9: not used 0.000E+00 --- RAD_SHAPE( 9)
R017 Outer annular radius (m), ring 10: not used 0.000E+00 --- RAD_SHAPE(10)
R017 Outer annular radius (m), ring 11: not used 0.000E+00 --- RAD_SHAPE(11)
R017 Outer annular radius (m), ring 12: not used 0.000E+00 --- RAD_SHAPE(12)
R017 Fractions of annular areas within AREA:
R017 Ring 1 not used 1.000E+00 --- FRACA( 1)
R017 Ring 2 not used 2.732E-01 --- FRACA( 2)
R017 Ring 3 not used 0.000E+00 --- FRACA( 3)
R017 Ring 4 not used 0.000E+00 --- FRACA( 4)
R017 Ring 5 not used 0.000E+00 --- FRACA( 5)
R017 Ring 6 not used 0.000E+00 --- FRACA( 6)
R017 Ring 7 not used 0.000E+00 --- FRACA( 7)
R017 Ring 8 not used 0.000E+00 --- FRACA( 8)
R017 Ring 9 not used 0.000E+00 --- FRACA( 9)
R017 Ring 10 not used 0.000E+00 --- FRACA(10)
R017 Ring 11 not used 0.000E+00 --- FRACA(11)
R017 Ring 12 not used 0.000E+00 --- FRACA(12)
R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 --- DIET(1)
R018 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 --- DIET(2)
R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 --- DIET(3)
R018 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 --- DIET(4)
R018 Fish consumption (kg/yr) 2.060E+01 5.400E+00 --- DIET(5)
R018 Other seafood consumption (kg/yr) 9.000E-01 9.000E-01 --- DIET(6)
R018 Soil ingestion rate (g/yr) 1.826E+01 3.650E+01 --- SOIL R018 Drinking water intake (L/yr) 4.785E+02 5.100E+02 --- DWI
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:53 Page 5 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : SB125-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R018 Contamination fraction of drinking water 1.000E+00 1.000E+00 --- FDW R018 Contamination fraction of household water not used 1.000E+00 --- FHHW R018 Contamination fraction of livestock water 1.000E+00 1.000E+00 --- FLW R018 Contamination fraction of irrigation water 1.000E+00 1.000E+00 --- FIRW R018 Contamination fraction of aquatic food 1.000E+00 5.000E-01 --- FR9 R018 Contamination fraction of plant food 1.000E+00 -1 --- FPLANT R018 Contamination fraction of meat 1.000E+00 -1 --- FMEAT R018 Contamination fraction of milk 1.000E+00 -1 --- FMILK R019 Livestock fodder intake for meat (kg/day) 2.710E+01 6.800E+01 --- LFI5 R019 Livestock fodder intake for milk (kg/day) 6.320E+01 5.500E+01 --- LFI6 R019 Livestock water intake for meat (L/day) 5.060E+01 5.000E+01 --- LWI5 R019 Livestock water intake for milk (L/day) 6.000E+01 1.600E+02 --- LWI6 R019 Livestock soil intake (kg/day) 5.000E-01 5.000E-01 --- LSI R019 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.000E-04 --- MLFD R019 Depth of soil mixing layer (m) 2.300E-01 1.500E-01 --- DM R019 Depth of roots (m) 2.050E+00 9.000E-01 --- DROOT R019 Drinking water fraction from ground water 1.000E+00 1.000E+00 --- FGWDW R019 Household water fraction from ground water not used 1.000E+00 --- FGWHH R019 Livestock water fraction from ground water 1.000E+00 1.000E+00 --- FGWLW R019 Irrigation fraction from ground water 1.000E+00 1.000E+00 --- FGWIR R19B Wet weight crop yield for Non-Leafy (kg/m**2) 1.750E+00 7.000E-01 --- YV(1)
R19B Wet weight crop yield for Leafy (kg/m**2) 2.889E+00 1.500E+00 --- YV(2)
R19B Wet weight crop yield for Fodder (kg/m**2) 1.887E+00 1.100E+00 --- YV(3)
R19B Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 --- TE(1)
R19B Growing Season for Leafy (years) 1.230E-01 2.500E-01 --- TE(2)
R19B Growing Season for Fodder (years) 8.200E-02 8.000E-02 --- TE(3)
R19B Translocation Factor for Non-Leafy 1.000E-01 1.000E-01 --- TIV(1)
R19B Translocation Factor for Leafy 1.000E+00 1.000E+00 --- TIV(2)
R19B Translocation Factor for Fodder 1.000E+00 1.000E+00 --- TIV(3)
R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RDRY(1)
R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 --- RDRY(2)
R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RDRY(3)
R19B Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RWET(1)
R19B Wet Foliar Interception Fraction for Leafy 5.800E-01 2.500E-01 --- RWET(2)
R19B Wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RWET(3)
R19B Weathering Removal Constant for Vegetation 3.300E+01 2.000E+01 --- WLAM C14 C-12 concentration in water (g/cm**3) not used 2.000E-05 --- C12WTR C14 C-12 concentration in contaminated soil (g/g) not used 3.000E-02 --- C12CZ C14 Fraction of vegetation carbon from soil not used 2.000E-02 --- CSOIL C14 Fraction of vegetation carbon from air not used 9.800E-01 --- CAIR C14 C-14 evasion layer thickness in soil (m) not used 3.000E-01 --- DMC C14 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 --- EVSN C14 C-12 evasion flux rate from soil (1/sec) not used 1.000E-10 --- REVSN C14 Fraction of grain in beef cattle feed not used 8.000E-01 --- AVFG4 C14 Fraction of grain in milk cow feed not used 2.000E-01 --- AVFG5 C14 DCF correction factor for gaseous forms of C14 not used 8.894E+01 --- CO2F
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:53 Page 6 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : SB125-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 --- STOR_T(1)
STOR Leafy vegetables 1.000E+00 1.000E+00 --- STOR_T(2)
STOR Milk 1.000E+00 1.000E+00 --- STOR_T(3)
STOR Meat and poultry 2.000E+01 2.000E+01 --- STOR_T(4)
STOR Fish 7.000E+00 7.000E+00 --- STOR_T(5)
STOR Crustacea and mollusks 7.000E+00 7.000E+00 --- STOR_T(6)
STOR Well water 1.000E+00 1.000E+00 --- STOR_T(7)
STOR Surface water 1.000E+00 1.000E+00 --- STOR_T(8)
STOR Livestock fodder 4.500E+01 4.500E+01 --- STOR_T(9)
R021 Thickness of building foundation (m) not used 1.500E-01 --- FLOOR1 R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 --- DENSFL R021 Total porosity of the cover material not used 4.000E-01 --- TPCV R021 Total porosity of the building foundation not used 1.000E-01 --- TPFL R021 Volumetric water content of the cover material not used 5.000E-02 --- PH2OCV R021 Volumetric water content of the foundation not used 3.000E-02 --- PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.000E-06 --- DIFCV R021 in foundation material not used 3.000E-07 --- DIFFL R021 in contaminated zone soil not used 2.000E-06 --- DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.000E+00 --- HMIX R021 Average building air exchange rate (1/hr) not used 5.000E-01 --- REXG R021 Height of the building (room) (m) not used 2.500E+00 --- HRM R021 Building interior area factor not used 0.000E+00 --- FAI R021 Building depth below ground surface (m) not used -1.000E+00 --- DMFL R021 Emanating power of Rn-222 gas not used 2.500E-01 --- EMANA(1)
R021 Emanating power of Rn-220 gas not used 1.500E-01 --- EMANA(2)
TITL Number of graphical time points 32 --- --- NPTS TITL Maximum number of integration points for dose 17 --- --- LYMAX TITL Maximum number of integration points for risk 1 --- --- KYMAX Summary of Pathway Selections Pathway User Selection 1 -- external gamma active 2 -- inhalation (w/o radon) active 3 -- plant ingestion active 4 -- meat ingestion active 5 -- milk ingestion active 6 -- aquatic foods active 7 -- drinking water active 8 -- soil ingestion active 9 -- radon suppressed Find peak pathway doses suppressed
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:53 Page 7 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : SB125-concrete-DCGL.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area: 5020.00 square meters Sb-125 1.000E+00 Thickness: 3.80 meters Cover Depth: 0.00 meters 0
Total Dose TDOSE(t), mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years): 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 TDOSE(t): 7.636E-01 5.946E-01 3.605E-01 6.252E-02 4.190E-04 1.032E-11 0.000E+00 0.000E+00 M(t): 3.055E-02 2.378E-02 1.442E-02 2.501E-03 1.676E-05 4.129E-13 0.000E+00 0.000E+00 0Maximum TDOSE(t): 7.636E-01 mrem/yr at t = 0.000E+00 years
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 08:53 Page 8 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : SB125-concrete-DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years 0 Water Independent Pathways (Inhalation excludes radon) 0 Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Sb-125 7.623E-01 0.9982 1.815E-07 0.0000 0.000E+00 0.0000 3.752E-05 0.0000 1.056E-04 0.0001 2.282E-05 0.0000 4.567E-05 0.0001 Total 7.623E-01 0.9982 1.815E-07 0.0000 0.000E+00 0.0000 3.752E-05 0.0000 1.056E-04 0.0001 2.282E-05 0.0000 4.567E-05 0.0001 0
Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years 0 Water Dependent Pathways 0 Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Sb-125 9.380E-04 0.0012 2.597E-05 0.0000 0.000E+00 0.0000 1.671E-04 0.0002 1.353E-05 0.0000 5.440E-06 0.0000 7.636E-01 1.0000 Total 9.380E-04 0.0012 2.597E-05 0.0000 0.000E+00 0.0000 1.671E-04 0.0002 1.353E-05 0.0000 5.440E-06 0.0000 7.636E-01 1.0000 0*Sum of all water independent and dependent pathways.
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:00 Page 1 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Sr-90-concrete-DCGL.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary ... 2 Site-Specific Parameter Summary .......................... 3 Summary of Pathway Selections ............................ 6 Contaminated Zone and Total Dose Summary ................. 7 Total Dose Components Time = 0.000E+00 .................................... 8 Time = 1.000E+00 .................................... 9 Time = 3.000E+00 .................................... 10 Time = 1.000E+01 .................................... 11 Time = 3.000E+01 .................................... 12 Time = 1.000E+02 .................................... 13 Time = 3.000E+02 .................................... 14 Time = 1.000E+03 .................................... 15 Dose/Source Ratios Summed Over All Pathways .............. 16 Single Radionuclide Soil Guidelines ...................... 16 Dose Per Nuclide Summed Over All Pathways ................ 17 Soil Concentration Per Nuclide ........................... 17
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:00 Page 2 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Sr-90-concrete-DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary File: YR Concrete 0 Current Parameter Menu Parameter Value Default Name B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 Sr-90+D 1.310E-03 1.310E-03 DCF2( 1)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Sr-90+D 1.530E-04 1.530E-04 DCF3( 1)
D-34 Food transfer factors:
D-34 Sr-90+D , plant/soil concentration ratio, dimensionless 6.420E-01 3.000E-01 RTF( 1,1)
D-34 Sr-90+D , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.300E-02 8.000E-03 RTF( 1,2)
D-34 Sr-90+D , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 2.810E-03 2.000E-03 RTF( 1,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Sr-90+D , fish 6.000E+01 6.000E+01 BIOFAC( 1,1)
D-5 Sr-90+D , crustacea and mollusks 1.000E+02 1.000E+02 BIOFAC( 1,2)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:00 Page 3 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Sr-90-concrete-DCGL.RAD Site-Specific Parameter Summary 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R011 Area of contaminated zone (m**2) 5.020E+03 1.000E+04 --- AREA R011 Thickness of contaminated zone (m) 3.800E+00 2.000E+00 --- THICK0 R011 Length parallel to aquifer flow (m) 8.000E+01 1.000E+02 --- LCZPAQ R011 Basic radiation dose limit (mrem/yr) 2.500E+01 2.500E+01 --- BRDL R011 Time since placement of material (yr) 0.000E+00 0.000E+00 --- TI R011 Times for calculations (yr) 1.000E+00 1.000E+00 --- T( 2)
R011 Times for calculations (yr) 3.000E+00 3.000E+00 --- T( 3)
R011 Times for calculations (yr) 1.000E+01 1.000E+01 --- T( 4)
R011 Times for calculations (yr) 3.000E+01 3.000E+01 --- T( 5)
R011 Times for calculations (yr) 1.000E+02 1.000E+02 --- T( 6)
R011 Times for calculations (yr) 3.000E+02 3.000E+02 --- T( 7)
R011 Times for calculations (yr) 1.000E+03 1.000E+03 --- T( 8)
R011 Times for calculations (yr) not used 0.000E+00 --- T( 9)
R011 Times for calculations (yr) not used 0.000E+00 --- T(10)
R012 Initial principal radionuclide (pCi/g): Sr-90 1.000E+00 0.000E+00 --- S1( 1)
R012 Concentration in groundwater (pCi/L): Sr-90 not used 0.000E+00 --- W1( 1)
R013 Cover depth (m) 0.000E+00 0.000E+00 --- COVER0 R013 Density of cover material (g/cm**3) not used 1.500E+00 --- DENSCV R013 Cover depth erosion rate (m/yr) not used 1.000E-03 --- VCV R013 Density of contaminated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSCZ R013 Contaminated zone erosion rate (m/yr) 8.500E-04 1.000E-03 --- VCZ R013 Contaminated zone total porosity 3.000E-01 4.000E-01 --- TPCZ R013 Contaminated zone field capacity 7.000E-02 2.000E-01 --- FCCZ R013 Contaminated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+01 --- HCCZ R013 Contaminated zone b parameter 9.750E-01 5.300E+00 --- BCZ R013 Average annual wind speed (m/sec) 2.030E+00 2.000E+00 --- WIND R013 Humidity in air (g/m**3) not used 8.000E+00 --- HUMID R013 Evapotranspiration coefficient 6.250E-01 5.000E-01 --- EVAPTR R013 Precipitation (m/yr) 1.200E+00 1.000E+00 --- PRECIP R013 Irrigation (m/yr) 4.350E-01 2.000E-01 --- RI R013 Irrigation mode overhead overhead --- IDITCH R013 Runoff coefficient 6.000E-01 2.000E-01 --- RUNOFF R013 Watershed area for nearby stream or pond (m**2) 7.770E+05 1.000E+06 --- WAREA R013 Accuracy for water/soil computations 1.000E-03 1.000E-03 --- EPS R014 Density of saturated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSAQ R014 Saturated zone total porosity 2.800E-01 4.000E-01 --- TPSZ R014 Saturated zone effective porosity 2.100E-01 2.000E-01 --- EPSZ R014 Saturated zone field capacity 7.000E-02 2.000E-01 --- FCSZ R014 Saturated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+02 --- HCSZ R014 Saturated zone hydraulic gradient 1.000E-01 2.000E-02 --- HGWT R014 Saturated zone b parameter 9.750E-01 5.300E+00 --- BSZ R014 Water table drop rate (m/yr) 1.000E-03 1.000E-03 --- VWT R014 Well pump intake depth (m below water table) 1.000E+01 1.000E+01 --- DWIBWT R014 Model: Nondispersion (ND) or Mass-Balance (MB) MB ND --- MODEL R014 Well pumping rate (m**3/yr) 2.500E+02 2.500E+02 --- UW R015 Number of unsaturated zone strata 0 1 --- NS
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:00 Page 4 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Sr-90-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R016 Distribution coefficients for Sr-90 R016 Contaminated zone (cm**3/g) 1.050E+01 3.000E+01 --- DCNUCC( 1)
R016 Saturated zone (cm**3/g) 0.000E+00 3.000E+01 --- DCNUCS( 1)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 5.560E-03 ALEACH( 1)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 1)
R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 --- INHALR R017 Mass loading for inhalation (g/m**3) 2.330E-05 1.000E-04 --- MLINH R017 Exposure duration 3.000E+01 3.000E+01 --- ED R017 Shielding factor, inhalation 5.500E-01 4.000E-01 --- SHF3 R017 Shielding factor, external gamma 2.725E-01 7.000E-01 --- SHF1 R017 Fraction of time spent indoors 6.571E-01 5.000E-01 --- FIND R017 Fraction of time spent outdoors (on site) 1.181E-01 2.500E-01 --- FOTD R017 Shape factor flag, external gamma 1.000E+00 1.000E+00 >0 shows circular AREA. FS R017 Radii of shape factor array (used if FS = -1):
R017 Outer annular radius (m), ring 1: not used 5.000E+01 --- RAD_SHAPE( 1)
R017 Outer annular radius (m), ring 2: not used 7.071E+01 --- RAD_SHAPE( 2)
R017 Outer annular radius (m), ring 3: not used 0.000E+00 --- RAD_SHAPE( 3)
R017 Outer annular radius (m), ring 4: not used 0.000E+00 --- RAD_SHAPE( 4)
R017 Outer annular radius (m), ring 5: not used 0.000E+00 --- RAD_SHAPE( 5)
R017 Outer annular radius (m), ring 6: not used 0.000E+00 --- RAD_SHAPE( 6)
R017 Outer annular radius (m), ring 7: not used 0.000E+00 --- RAD_SHAPE( 7)
R017 Outer annular radius (m), ring 8: not used 0.000E+00 --- RAD_SHAPE( 8)
R017 Outer annular radius (m), ring 9: not used 0.000E+00 --- RAD_SHAPE( 9)
R017 Outer annular radius (m), ring 10: not used 0.000E+00 --- RAD_SHAPE(10)
R017 Outer annular radius (m), ring 11: not used 0.000E+00 --- RAD_SHAPE(11)
R017 Outer annular radius (m), ring 12: not used 0.000E+00 --- RAD_SHAPE(12)
R017 Fractions of annular areas within AREA:
R017 Ring 1 not used 1.000E+00 --- FRACA( 1)
R017 Ring 2 not used 2.732E-01 --- FRACA( 2)
R017 Ring 3 not used 0.000E+00 --- FRACA( 3)
R017 Ring 4 not used 0.000E+00 --- FRACA( 4)
R017 Ring 5 not used 0.000E+00 --- FRACA( 5)
R017 Ring 6 not used 0.000E+00 --- FRACA( 6)
R017 Ring 7 not used 0.000E+00 --- FRACA( 7)
R017 Ring 8 not used 0.000E+00 --- FRACA( 8)
R017 Ring 9 not used 0.000E+00 --- FRACA( 9)
R017 Ring 10 not used 0.000E+00 --- FRACA(10)
R017 Ring 11 not used 0.000E+00 --- FRACA(11)
R017 Ring 12 not used 0.000E+00 --- FRACA(12)
R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 --- DIET(1)
R018 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 --- DIET(2)
R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 --- DIET(3)
R018 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 --- DIET(4)
R018 Fish consumption (kg/yr) 2.060E+01 5.400E+00 --- DIET(5)
R018 Other seafood consumption (kg/yr) 9.000E-01 9.000E-01 --- DIET(6)
R018 Soil ingestion rate (g/yr) 1.826E+01 3.650E+01 --- SOIL R018 Drinking water intake (L/yr) 4.785E+02 5.100E+02 --- DWI
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:00 Page 5 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Sr-90-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R018 Contamination fraction of drinking water 1.000E+00 1.000E+00 --- FDW R018 Contamination fraction of household water not used 1.000E+00 --- FHHW R018 Contamination fraction of livestock water 1.000E+00 1.000E+00 --- FLW R018 Contamination fraction of irrigation water 1.000E+00 1.000E+00 --- FIRW R018 Contamination fraction of aquatic food 1.000E+00 5.000E-01 --- FR9 R018 Contamination fraction of plant food 1.000E+00 -1 --- FPLANT R018 Contamination fraction of meat 1.000E+00 -1 --- FMEAT R018 Contamination fraction of milk 1.000E+00 -1 --- FMILK R019 Livestock fodder intake for meat (kg/day) 2.710E+01 6.800E+01 --- LFI5 R019 Livestock fodder intake for milk (kg/day) 6.320E+01 5.500E+01 --- LFI6 R019 Livestock water intake for meat (L/day) 5.060E+01 5.000E+01 --- LWI5 R019 Livestock water intake for milk (L/day) 6.000E+01 1.600E+02 --- LWI6 R019 Livestock soil intake (kg/day) 5.000E-01 5.000E-01 --- LSI R019 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.000E-04 --- MLFD R019 Depth of soil mixing layer (m) 2.300E-01 1.500E-01 --- DM R019 Depth of roots (m) 2.050E+00 9.000E-01 --- DROOT R019 Drinking water fraction from ground water 1.000E+00 1.000E+00 --- FGWDW R019 Household water fraction from ground water not used 1.000E+00 --- FGWHH R019 Livestock water fraction from ground water 1.000E+00 1.000E+00 --- FGWLW R019 Irrigation fraction from ground water 1.000E+00 1.000E+00 --- FGWIR R19B Wet weight crop yield for Non-Leafy (kg/m**2) 1.750E+00 7.000E-01 --- YV(1)
R19B Wet weight crop yield for Leafy (kg/m**2) 2.889E+00 1.500E+00 --- YV(2)
R19B Wet weight crop yield for Fodder (kg/m**2) 1.887E+00 1.100E+00 --- YV(3)
R19B Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 --- TE(1)
R19B Growing Season for Leafy (years) 1.230E-01 2.500E-01 --- TE(2)
R19B Growing Season for Fodder (years) 8.200E-02 8.000E-02 --- TE(3)
R19B Translocation Factor for Non-Leafy 1.000E-01 1.000E-01 --- TIV(1)
R19B Translocation Factor for Leafy 1.000E+00 1.000E+00 --- TIV(2)
R19B Translocation Factor for Fodder 1.000E+00 1.000E+00 --- TIV(3)
R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RDRY(1)
R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 --- RDRY(2)
R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RDRY(3)
R19B Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RWET(1)
R19B Wet Foliar Interception Fraction for Leafy 5.800E-01 2.500E-01 --- RWET(2)
R19B Wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RWET(3)
R19B Weathering Removal Constant for Vegetation 2.150E+01 2.000E+01 --- WLAM C14 C-12 concentration in water (g/cm**3) not used 2.000E-05 --- C12WTR C14 C-12 concentration in contaminated soil (g/g) not used 3.000E-02 --- C12CZ C14 Fraction of vegetation carbon from soil not used 2.000E-02 --- CSOIL C14 Fraction of vegetation carbon from air not used 9.800E-01 --- CAIR C14 C-14 evasion layer thickness in soil (m) not used 3.000E-01 --- DMC C14 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 --- EVSN C14 C-12 evasion flux rate from soil (1/sec) not used 1.000E-10 --- REVSN C14 Fraction of grain in beef cattle feed not used 8.000E-01 --- AVFG4 C14 Fraction of grain in milk cow feed not used 2.000E-01 --- AVFG5 C14 DCF correction factor for gaseous forms of C14 not used 8.894E+01 --- CO2F
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:00 Page 6 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Sr-90-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 --- STOR_T(1)
STOR Leafy vegetables 1.000E+00 1.000E+00 --- STOR_T(2)
STOR Milk 1.000E+00 1.000E+00 --- STOR_T(3)
STOR Meat and poultry 2.000E+01 2.000E+01 --- STOR_T(4)
STOR Fish 7.000E+00 7.000E+00 --- STOR_T(5)
STOR Crustacea and mollusks 7.000E+00 7.000E+00 --- STOR_T(6)
STOR Well water 1.000E+00 1.000E+00 --- STOR_T(7)
STOR Surface water 1.000E+00 1.000E+00 --- STOR_T(8)
STOR Livestock fodder 4.500E+01 4.500E+01 --- STOR_T(9)
R021 Thickness of building foundation (m) not used 1.500E-01 --- FLOOR1 R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 --- DENSFL R021 Total porosity of the cover material not used 4.000E-01 --- TPCV R021 Total porosity of the building foundation not used 1.000E-01 --- TPFL R021 Volumetric water content of the cover material not used 5.000E-02 --- PH2OCV R021 Volumetric water content of the foundation not used 3.000E-02 --- PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.000E-06 --- DIFCV R021 in foundation material not used 3.000E-07 --- DIFFL R021 in contaminated zone soil not used 2.000E-06 --- DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.000E+00 --- HMIX R021 Average building air exchange rate (1/hr) not used 5.000E-01 --- REXG R021 Height of the building (room) (m) not used 2.500E+00 --- HRM R021 Building interior area factor not used 0.000E+00 --- FAI R021 Building depth below ground surface (m) not used -1.000E+00 --- DMFL R021 Emanating power of Rn-222 gas not used 2.500E-01 --- EMANA(1)
R021 Emanating power of Rn-220 gas not used 1.500E-01 --- EMANA(2)
TITL Number of graphical time points 32 --- --- NPTS TITL Maximum number of integration points for dose 17 --- --- LYMAX TITL Maximum number of integration points for risk 1 --- --- KYMAX Summary of Pathway Selections Pathway User Selection 1 -- external gamma active 2 -- inhalation (w/o radon) active 3 -- plant ingestion active 4 -- meat ingestion active 5 -- milk ingestion active 6 -- aquatic foods active 7 -- drinking water active 8 -- soil ingestion active 9 -- radon suppressed Find peak pathway doses suppressed
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:00 Page 7 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Sr-90-concrete-DCGL.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area: 5020.00 square meters Sr-90 1.000E+00 Thickness: 3.80 meters Cover Depth: 0.00 meters 0
Total Dose TDOSE(t), mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years): 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 TDOSE(t): 3.161E+01 3.153E+01 2.972E+01 2.418E+01 1.342E+01 1.707E+00 4.718E-03 5.223E-12 M(t): 1.264E+00 1.261E+00 1.189E+00 9.674E-01 5.367E-01 6.829E-02 1.887E-04 2.089E-13 0Maximum TDOSE(t): 3.161E+01 mrem/yr at t = 0.000E+00 years
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:00 Page 8 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Sr-90-concrete-DCGL.RAD Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years 0 Water Independent Pathways (Inhalation excludes radon) 0 Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Sr-90 6.674E-03 0.0002 1.911E-05 0.0000 0.000E+00 0.0000 1.291E+01 0.4085 2.286E+00 0.0723 4.057E+00 0.1283 2.134E-03 0.0001 Total 6.674E-03 0.0002 1.911E-05 0.0000 0.000E+00 0.0000 1.291E+01 0.4085 2.286E+00 0.0723 4.057E+00 0.1283 2.134E-03 0.0001 0
Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 0.000E+00 years 0 Water Dependent Pathways 0 Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Sr-90 6.483E+00 0.2051 1.162E-01 0.0037 0.000E+00 0.0000 2.026E+00 0.0641 1.472E+00 0.0466 2.248E+00 0.0711 3.161E+01 1.0000 Total 6.483E+00 0.2051 1.162E-01 0.0037 0.000E+00 0.0000 2.026E+00 0.0641 1.472E+00 0.0466 2.248E+00 0.0711 3.161E+01 1.0000 0*Sum of all water independent and dependent pathways.
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:04 Page 1 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Tc99-concrete-DCGL.RAD Table of Contents Part I: Mixture Sums and Single Radionuclide Guidelines Dose Conversion Factor (and Related) Parameter Summary ... 2 Site-Specific Parameter Summary .......................... 3 Summary of Pathway Selections ............................ 6 Contaminated Zone and Total Dose Summary ................. 7 Total Dose Components Time = 0.000E+00 .................................... 8 Time = 1.000E+00 .................................... 9 Time = 3.000E+00 .................................... 10 Time = 1.000E+01 .................................... 11 Time = 3.000E+01 .................................... 12 Time = 1.000E+02 .................................... 13 Time = 3.000E+02 .................................... 14 Time = 1.000E+03 .................................... 15 Dose/Source Ratios Summed Over All Pathways .............. 16 Single Radionuclide Soil Guidelines ...................... 16 Dose Per Nuclide Summed Over All Pathways ................ 17 Soil Concentration Per Nuclide ........................... 17
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:04 Page 2 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Tc99-concrete-DCGL.RAD Dose Conversion Factor (and Related) Parameter Summary File: YR Concrete 0 Current Parameter Menu Parameter Value Default Name B-1 Dose conversion factors for inhalation, mrem/pCi:
B-1 Tc-99 8.330E-06 8.330E-06 DCF2( 1)
D-1 Dose conversion factors for ingestion, mrem/pCi:
D-1 Tc-99 1.460E-06 1.460E-06 DCF3( 1)
D-34 Food transfer factors:
D-34 Tc-99 , plant/soil concentration ratio, dimensionless 1.340E+00 5.000E+00 RTF( 1,1)
D-34 Tc-99 , beef/livestock-intake ratio, (pCi/kg)/(pCi/d) 1.000E-04 1.000E-04 RTF( 1,2)
D-34 Tc-99 , milk/livestock-intake ratio, (pCi/L)/(pCi/d) 1.600E-03 1.000E-03 RTF( 1,3)
D-5 Bioaccumulation factors, fresh water, L/kg:
D-5 Tc-99 , fish 2.000E+01 2.000E+01 BIOFAC( 1,1)
D-5 Tc-99 , crustacea and mollusks 5.000E+00 5.000E+00 BIOFAC( 1,2)
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:04 Page 3 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Tc99-concrete-DCGL.RAD Site-Specific Parameter Summary 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R011 Area of contaminated zone (m**2) 5.020E+03 1.000E+04 --- AREA R011 Thickness of contaminated zone (m) 3.800E+00 2.000E+00 --- THICK0 R011 Length parallel to aquifer flow (m) 8.000E+01 1.000E+02 --- LCZPAQ R011 Basic radiation dose limit (mrem/yr) 2.500E+01 2.500E+01 --- BRDL R011 Time since placement of material (yr) 0.000E+00 0.000E+00 --- TI R011 Times for calculations (yr) 1.000E+00 1.000E+00 --- T( 2)
R011 Times for calculations (yr) 3.000E+00 3.000E+00 --- T( 3)
R011 Times for calculations (yr) 1.000E+01 1.000E+01 --- T( 4)
R011 Times for calculations (yr) 3.000E+01 3.000E+01 --- T( 5)
R011 Times for calculations (yr) 1.000E+02 1.000E+02 --- T( 6)
R011 Times for calculations (yr) 3.000E+02 3.000E+02 --- T( 7)
R011 Times for calculations (yr) 1.000E+03 1.000E+03 --- T( 8)
R011 Times for calculations (yr) not used 0.000E+00 --- T( 9)
R011 Times for calculations (yr) not used 0.000E+00 --- T(10)
R012 Initial principal radionuclide (pCi/g): Tc-99 1.000E+00 0.000E+00 --- S1( 1)
R012 Concentration in groundwater (pCi/L): Tc-99 not used 0.000E+00 --- W1( 1)
R013 Cover depth (m) 0.000E+00 0.000E+00 --- COVER0 R013 Density of cover material (g/cm**3) not used 1.500E+00 --- DENSCV R013 Cover depth erosion rate (m/yr) not used 1.000E-03 --- VCV R013 Density of contaminated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSCZ R013 Contaminated zone erosion rate (m/yr) 8.500E-04 1.000E-03 --- VCZ R013 Contaminated zone total porosity 3.000E-01 4.000E-01 --- TPCZ R013 Contaminated zone field capacity 7.000E-02 2.000E-01 --- FCCZ R013 Contaminated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+01 --- HCCZ R013 Contaminated zone b parameter 9.750E-01 5.300E+00 --- BCZ R013 Average annual wind speed (m/sec) 2.030E+00 2.000E+00 --- WIND R013 Humidity in air (g/m**3) not used 8.000E+00 --- HUMID R013 Evapotranspiration coefficient 6.250E-01 5.000E-01 --- EVAPTR R013 Precipitation (m/yr) 1.200E+00 1.000E+00 --- PRECIP R013 Irrigation (m/yr) 4.350E-01 2.000E-01 --- RI R013 Irrigation mode overhead overhead --- IDITCH R013 Runoff coefficient 6.000E-01 2.000E-01 --- RUNOFF R013 Watershed area for nearby stream or pond (m**2) 7.770E+05 1.000E+06 --- WAREA R013 Accuracy for water/soil computations 1.000E-03 1.000E-03 --- EPS R014 Density of saturated zone (g/cm**3) 1.540E+00 1.500E+00 --- DENSAQ R014 Saturated zone total porosity 2.800E-01 4.000E-01 --- TPSZ R014 Saturated zone effective porosity 2.100E-01 2.000E-01 --- EPSZ R014 Saturated zone field capacity 7.000E-02 2.000E-01 --- FCSZ R014 Saturated zone hydraulic conductivity (m/yr) 3.160E+05 1.000E+02 --- HCSZ R014 Saturated zone hydraulic gradient 1.000E-01 2.000E-02 --- HGWT R014 Saturated zone b parameter 9.750E-01 5.300E+00 --- BSZ R014 Water table drop rate (m/yr) 1.000E-03 1.000E-03 --- VWT R014 Well pump intake depth (m below water table) 1.000E+01 1.000E+01 --- DWIBWT R014 Model: Nondispersion (ND) or Mass-Balance (MB) MB ND --- MODEL R014 Well pumping rate (m**3/yr) 2.500E+02 2.500E+02 --- UW R015 Number of unsaturated zone strata 0 1 --- NS
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:04 Page 4 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Tc99-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R016 Distribution coefficients for Tc-99 R016 Contaminated zone (cm**3/g) 1.350E+01 0.000E+00 --- DCNUCC( 1)
R016 Saturated zone (cm**3/g) 0.000E+00 0.000E+00 --- DCNUCS( 1)
R016 Leach rate (/yr) 0.000E+00 0.000E+00 4.329E-03 ALEACH( 1)
R016 Solubility constant 0.000E+00 0.000E+00 not used SOLUBK( 1)
R017 Inhalation rate (m**3/yr) 8.400E+03 8.400E+03 --- INHALR R017 Mass loading for inhalation (g/m**3) 2.330E-05 1.000E-04 --- MLINH R017 Exposure duration 3.000E+01 3.000E+01 --- ED R017 Shielding factor, inhalation 5.500E-01 4.000E-01 --- SHF3 R017 Shielding factor, external gamma 2.725E-01 7.000E-01 --- SHF1 R017 Fraction of time spent indoors 6.571E-01 5.000E-01 --- FIND R017 Fraction of time spent outdoors (on site) 1.181E-01 2.500E-01 --- FOTD R017 Shape factor flag, external gamma 1.000E+00 1.000E+00 >0 shows circular AREA. FS R017 Radii of shape factor array (used if FS = -1):
R017 Outer annular radius (m), ring 1: not used 5.000E+01 --- RAD_SHAPE( 1)
R017 Outer annular radius (m), ring 2: not used 7.071E+01 --- RAD_SHAPE( 2)
R017 Outer annular radius (m), ring 3: not used 0.000E+00 --- RAD_SHAPE( 3)
R017 Outer annular radius (m), ring 4: not used 0.000E+00 --- RAD_SHAPE( 4)
R017 Outer annular radius (m), ring 5: not used 0.000E+00 --- RAD_SHAPE( 5)
R017 Outer annular radius (m), ring 6: not used 0.000E+00 --- RAD_SHAPE( 6)
R017 Outer annular radius (m), ring 7: not used 0.000E+00 --- RAD_SHAPE( 7)
R017 Outer annular radius (m), ring 8: not used 0.000E+00 --- RAD_SHAPE( 8)
R017 Outer annular radius (m), ring 9: not used 0.000E+00 --- RAD_SHAPE( 9)
R017 Outer annular radius (m), ring 10: not used 0.000E+00 --- RAD_SHAPE(10)
R017 Outer annular radius (m), ring 11: not used 0.000E+00 --- RAD_SHAPE(11)
R017 Outer annular radius (m), ring 12: not used 0.000E+00 --- RAD_SHAPE(12)
R017 Fractions of annular areas within AREA:
R017 Ring 1 not used 1.000E+00 --- FRACA( 1)
R017 Ring 2 not used 2.732E-01 --- FRACA( 2)
R017 Ring 3 not used 0.000E+00 --- FRACA( 3)
R017 Ring 4 not used 0.000E+00 --- FRACA( 4)
R017 Ring 5 not used 0.000E+00 --- FRACA( 5)
R017 Ring 6 not used 0.000E+00 --- FRACA( 6)
R017 Ring 7 not used 0.000E+00 --- FRACA( 7)
R017 Ring 8 not used 0.000E+00 --- FRACA( 8)
R017 Ring 9 not used 0.000E+00 --- FRACA( 9)
R017 Ring 10 not used 0.000E+00 --- FRACA(10)
R017 Ring 11 not used 0.000E+00 --- FRACA(11)
R017 Ring 12 not used 0.000E+00 --- FRACA(12)
R018 Fruits, vegetables and grain consumption (kg/yr) 1.120E+02 1.600E+02 --- DIET(1)
R018 Leafy vegetable consumption (kg/yr) 2.140E+01 1.400E+01 --- DIET(2)
R018 Milk consumption (L/yr) 2.330E+02 9.200E+01 --- DIET(3)
R018 Meat and poultry consumption (kg/yr) 6.510E+01 6.300E+01 --- DIET(4)
R018 Fish consumption (kg/yr) 2.060E+01 5.400E+00 --- DIET(5)
R018 Other seafood consumption (kg/yr) 9.000E-01 9.000E-01 --- DIET(6)
R018 Soil ingestion rate (g/yr) 1.826E+01 3.650E+01 --- SOIL R018 Drinking water intake (L/yr) 4.785E+02 5.100E+02 --- DWI
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:04 Page 5 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Tc99-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name R018 Contamination fraction of drinking water 1.000E+00 1.000E+00 --- FDW R018 Contamination fraction of household water not used 1.000E+00 --- FHHW R018 Contamination fraction of livestock water 1.000E+00 1.000E+00 --- FLW R018 Contamination fraction of irrigation water 1.000E+00 1.000E+00 --- FIRW R018 Contamination fraction of aquatic food 1.000E+00 5.000E-01 --- FR9 R018 Contamination fraction of plant food 1.000E+00 -1 --- FPLANT R018 Contamination fraction of meat 1.000E+00 -1 --- FMEAT R018 Contamination fraction of milk 1.000E+00 -1 --- FMILK R019 Livestock fodder intake for meat (kg/day) 2.710E+01 6.800E+01 --- LFI5 R019 Livestock fodder intake for milk (kg/day) 6.320E+01 5.500E+01 --- LFI6 R019 Livestock water intake for meat (L/day) 5.060E+01 5.000E+01 --- LWI5 R019 Livestock water intake for milk (L/day) 6.000E+01 1.600E+02 --- LWI6 R019 Livestock soil intake (kg/day) 5.000E-01 5.000E-01 --- LSI R019 Mass loading for foliar deposition (g/m**3) 4.000E-04 1.000E-04 --- MLFD R019 Depth of soil mixing layer (m) 2.300E-01 1.500E-01 --- DM R019 Depth of roots (m) 2.050E+00 9.000E-01 --- DROOT R019 Drinking water fraction from ground water 1.000E+00 1.000E+00 --- FGWDW R019 Household water fraction from ground water not used 1.000E+00 --- FGWHH R019 Livestock water fraction from ground water 1.000E+00 1.000E+00 --- FGWLW R019 Irrigation fraction from ground water 1.000E+00 1.000E+00 --- FGWIR R19B Wet weight crop yield for Non-Leafy (kg/m**2) 1.750E+00 7.000E-01 --- YV(1)
R19B Wet weight crop yield for Leafy (kg/m**2) 2.889E+00 1.500E+00 --- YV(2)
R19B Wet weight crop yield for Fodder (kg/m**2) 1.887E+00 1.100E+00 --- YV(3)
R19B Growing Season for Non-Leafy (years) 2.460E-01 1.700E-01 --- TE(1)
R19B Growing Season for Leafy (years) 1.230E-01 2.500E-01 --- TE(2)
R19B Growing Season for Fodder (years) 8.200E-02 8.000E-02 --- TE(3)
R19B Translocation Factor for Non-Leafy 1.000E-01 1.000E-01 --- TIV(1)
R19B Translocation Factor for Leafy 1.000E+00 1.000E+00 --- TIV(2)
R19B Translocation Factor for Fodder 1.000E+00 1.000E+00 --- TIV(3)
R19B Dry Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RDRY(1)
R19B Dry Foliar Interception Fraction for Leafy 3.500E-01 2.500E-01 --- RDRY(2)
R19B Dry Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RDRY(3)
R19B Wet Foliar Interception Fraction for Non-Leafy 3.500E-01 2.500E-01 --- RWET(1)
R19B Wet Foliar Interception Fraction for Leafy 5.800E-01 2.500E-01 --- RWET(2)
R19B Wet Foliar Interception Fraction for Fodder 3.500E-01 2.500E-01 --- RWET(3)
R19B Weathering Removal Constant for Vegetation 2.150E+01 2.000E+01 --- WLAM C14 C-12 concentration in water (g/cm**3) not used 2.000E-05 --- C12WTR C14 C-12 concentration in contaminated soil (g/g) not used 3.000E-02 --- C12CZ C14 Fraction of vegetation carbon from soil not used 2.000E-02 --- CSOIL C14 Fraction of vegetation carbon from air not used 9.800E-01 --- CAIR C14 C-14 evasion layer thickness in soil (m) not used 3.000E-01 --- DMC C14 C-14 evasion flux rate from soil (1/sec) not used 7.000E-07 --- EVSN C14 C-12 evasion flux rate from soil (1/sec) not used 1.000E-10 --- REVSN C14 Fraction of grain in beef cattle feed not used 8.000E-01 --- AVFG4 C14 Fraction of grain in milk cow feed not used 2.000E-01 --- AVFG5 C14 DCF correction factor for gaseous forms of C14 not used 8.894E+01 --- CO2F
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:04 Page 6 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Tc99-concrete-DCGL.RAD Site-Specific Parameter Summary (continued) 0 User Used by RESRAD Parameter Menu Parameter Input Default (If different from user input) Name STOR Storage times of contaminated foodstuffs (days):
STOR Fruits, non-leafy vegetables, and grain 1.400E+01 1.400E+01 --- STOR_T(1)
STOR Leafy vegetables 1.000E+00 1.000E+00 --- STOR_T(2)
STOR Milk 1.000E+00 1.000E+00 --- STOR_T(3)
STOR Meat and poultry 2.000E+01 2.000E+01 --- STOR_T(4)
STOR Fish 7.000E+00 7.000E+00 --- STOR_T(5)
STOR Crustacea and mollusks 7.000E+00 7.000E+00 --- STOR_T(6)
STOR Well water 1.000E+00 1.000E+00 --- STOR_T(7)
STOR Surface water 1.000E+00 1.000E+00 --- STOR_T(8)
STOR Livestock fodder 4.500E+01 4.500E+01 --- STOR_T(9)
R021 Thickness of building foundation (m) not used 1.500E-01 --- FLOOR1 R021 Bulk density of building foundation (g/cm**3) not used 2.400E+00 --- DENSFL R021 Total porosity of the cover material not used 4.000E-01 --- TPCV R021 Total porosity of the building foundation not used 1.000E-01 --- TPFL R021 Volumetric water content of the cover material not used 5.000E-02 --- PH2OCV R021 Volumetric water content of the foundation not used 3.000E-02 --- PH2OFL R021 Diffusion coefficient for radon gas (m/sec):
R021 in cover material not used 2.000E-06 --- DIFCV R021 in foundation material not used 3.000E-07 --- DIFFL R021 in contaminated zone soil not used 2.000E-06 --- DIFCZ R021 Radon vertical dimension of mixing (m) not used 2.000E+00 --- HMIX R021 Average building air exchange rate (1/hr) not used 5.000E-01 --- REXG R021 Height of the building (room) (m) not used 2.500E+00 --- HRM R021 Building interior area factor not used 0.000E+00 --- FAI R021 Building depth below ground surface (m) not used -1.000E+00 --- DMFL R021 Emanating power of Rn-222 gas not used 2.500E-01 --- EMANA(1)
R021 Emanating power of Rn-220 gas not used 1.500E-01 --- EMANA(2)
TITL Number of graphical time points 32 --- --- NPTS TITL Maximum number of integration points for dose 17 --- --- LYMAX TITL Maximum number of integration points for risk 1 --- --- KYMAX Summary of Pathway Selections Pathway User Selection 1 -- external gamma active 2 -- inhalation (w/o radon) active 3 -- plant ingestion active 4 -- meat ingestion active 5 -- milk ingestion active 6 -- aquatic foods active 7 -- drinking water active 8 -- soil ingestion active 9 -- radon suppressed Find peak pathway doses suppressed
1RESRAD, Version 6.21 T1/2 Limit = 0.5 year 08/06/2004 09:04 Page 7 Summary : YR submerged concrete- Intruder (no cover) Scenario-DCGL File : Tc99-concrete-DCGL.RAD Contaminated Zone Dimensions Initial Soil Concentrations, pCi/g Area: 5020.00 square meters Tc-99 1.000E+00 Thickness: 3.80 meters Cover Depth: 0.00 meters 0
Total Dose TDOSE(t), mrem/yr Basic Radiation Dose Limit = 2.500E+01 mrem/yr Total Mixture Sum M(t) = Fraction of Basic Dose Limit Received at Time (t) t (years): 0.000E+00 1.000E+00 3.000E+00 1.000E+01 3.000E+01 1.000E+02 3.000E+02 1.000E+03 TDOSE(t): 3.840E-01 3.868E-01 3.834E-01 3.718E-01 3.407E-01 2.507E-01 1.044E-01 4.867E-03 M(t): 1.536E-02 1.547E-02 1.534E-02 1.487E-02 1.363E-02 1.003E-02 4.177E-03 1.947E-04 0Maximum TDOSE(t): 3.881E-01 mrem/yr at t = 0.2263 +/- 0.0005 years 0
Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 2.263E-01 years 0 Water Independent Pathways (Inhalation excludes radon) 0 Ground Inhalation Radon Plant Meat Milk Soil Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Nuclide Tc-99 3.527E-05 0.0001 1.229E-07 0.0000 0.000E+00 0.0000 2.602E-01 0.6705 3.491E-04 0.0009 4.625E-02 0.1192 2.060E-05 0.0001 Total 3.527E-05 0.0001 1.229E-07 0.0000 0.000E+00 0.0000 2.602E-01 0.6705 3.491E-04 0.0009 4.625E-02 0.1192 2.060E-05 0.0001 0
Total Dose Contributions TDOSE(i,p,t) for Individual Radionuclides (i) and Pathways (p)
As mrem/yr and Fraction of Total Dose At t = 2.263E-01 years 0 Water Dependent Pathways 0 Water Fish Radon Plant Meat Milk All Pathways*
Radio-Nuclide mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract. mrem/yr fract.
Nuclide Tc-99 5.141E-02 0.1325 2.889E-04 0.0007 0.000E+00 0.0000 1.880E-02 0.0484 9.422E-05 0.0002 1.062E-02 0.0274 3.881E-01 1.0000 Total 5.141E-02 0.1325 2.889E-04 0.0007 0.000E+00 0.0000 1.880E-02 0.0484 9.422E-05 0.0002 1.062E-02 0.0274 3.881E-01 1.0000 0*Sum of all water independent and dependent pathways.