- RESRAD-BUILD Program Output, Version 3.21 11/29/03 11:11:00 Page: 2 **
Title : Yankee Rowe DCGL Ag-108m Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Ag-108m-DCGL_Build_nov28.bld RESRAD-BUILD Input Parameters Number of Sources : 5 Number of Receptors: 1 Total Time : 3.652500E+02 days Fraction Inside : 2.670000E-01 Receptor Information Receptor Room x y z FracTime Inhalation Ingestion(Dust)
[m] [m] [m] [m3/day] [m2/hr]
1 1 2.220 2.220 1.000 1.000 3.36E+01 0.00E+00 Receptor-Source Shielding Relationship Receptor Source Density Thickness Material
[g/cm3] [cm]
1 1 2.40E+00 0.00E+00 Concrete 1 2 2.40E+00 0.00E+00 Concrete 1 3 2.40E+00 0.00E+00 Concrete 1 4 2.40E+00 0.00E+00 Concrete 1 5 2.40E+00 0.00E+00 Concrete
- RESRAD-BUILD Program Output, Version 3.21 11/29/03 11:11:00 Page: 3 **
Title : Yankee Rowe DCGL Ag-108m Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Ag-108m-DCGL_Build_nov28.bld Building Information Building Air Exchange Rate: 1.52E+00 1/hr Height[m] Air Exchanges [m3/hr]
Area [m2]
- <=Q01: 1.05E+02 H1: 3.510
- Room 1
- Q10 : 1.05E+02
- LAMBDA: 1.52E+00
- Area 19.710 *
- Deposition velocity: 4.79E-04 [m/s] Resuspension Rate: 6.75E-10 [1/s]
- RESRAD-BUILD Program Output, Version 3.21 11/29/03 11:11:00 Page: 4 **
Title : Yankee Rowe DCGL Ag-108m Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Ag-108m-DCGL_Build_nov28.bld Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00[m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
AG-108m 1.000E+00 7.620E-06 2.830E-04 9.140E-03 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
AG-108m 1.000E+00 7.620E-06 2.830E-04 9.140E-03
- RESRAD-BUILD Program Output, Version 3.21 11/29/03 11:11:00 Page: 5 **
Title : Yankee Rowe DCGL Ag-108m Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Ag-108m-DCGL_Build_nov28.bld Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
AG-108m 1.000E+00 7.620E-06 2.830E-04 9.140E-03 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
AG-108m 1.000E+00 7.620E-06 2.830E-04 9.140E-03
- RESRAD-BUILD Program Output, Version 3.21 11/29/03 11:11:00 Page: 6 **
Title : Yankee Rowe DCGL Ag-108m Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Ag-108m-DCGL_Build_nov28.bld Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
AG-108m 1.000E+00 7.620E-06 2.830E-04 9.140E-03
- RESRAD-BUILD Program Output, Version 3.21 11/29/03 11:11:00 Page: 7 **
Title : Yankee Rowe DCGL Ag-108m Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Ag-108m-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years Assessment for Time: 1 Time =0.00E+00 yr Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00 [m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
AG-108m 1.000E+00 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
AG-108m 1.000E+00
- RESRAD-BUILD Program Output, Version 3.21 11/29/03 11:11:00 Page: 8 **
Title : Yankee Rowe DCGL Ag-108m Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Ag-108m-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
AG-108m 1.000E+00 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
AG-108m 1.000E+00 Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
AG-108m 1.000E+00
- RESRAD-BUILD Program Output, Version 3.21 11/29/03 11:11:00 Page: 9 **
Title : Yankee Rowe DCGL Ag-108m Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Ag-108m-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years RESRAD-BUILDDose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Total 1 2 3 4 5 Receptor 1 9.46E-06 3.20E-06 3.20E-06 3.20E-06 3.20E-06 2.22E-05 Total 9.46E-06 3.20E-06 3.20E-06 3.20E-06 3.20E-06 2.22E-05
- RESRAD-BUILD Program Output, Version 3.21 11/30/03 20:35:39 Page: 2 **
Title : Yankee Rowe DCGL Am-241 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Am-241-DCGL_Build_nov28.bld RESRAD-BUILD Input Parameters Number of Sources : 5 Number of Receptors: 1 Total Time : 3.652500E+02 days Fraction Inside : 2.670000E-01 Receptor Information Receptor Room x y z FracTime Inhalation Ingestion(Dust)
[m] [m] [m] [m3/day] [m2/hr]
1 1 2.220 2.220 1.000 1.000 3.36E+01 0.00E+00 Receptor-Source Shielding Relationship Receptor Source Density Thickness Material
[g/cm3] [cm]
1 1 2.40E+00 0.00E+00 Concrete 1 2 2.40E+00 0.00E+00 Concrete 1 3 2.40E+00 0.00E+00 Concrete 1 4 2.40E+00 0.00E+00 Concrete 1 5 2.40E+00 0.00E+00 Concrete
- RESRAD-BUILD Program Output, Version 3.21 11/30/03 20:35:39 Page: 3 **
Title : Yankee Rowe DCGL Am-241 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Am-241-DCGL_Build_nov28.bld Building Information Building Air Exchange Rate: 1.52E+00 1/hr Height[m] Air Exchanges [m3/hr]
Area [m2]
- <=Q01: 1.05E+02 H1: 3.510
- Room 1
- Q10 : 1.05E+02
- LAMBDA: 1.52E+00
- Area 19.710 *
- Deposition velocity: 8.53E-05 [m/s] Resuspension Rate: 1.83E-08 [1/s]
- RESRAD-BUILD Program Output, Version 3.21 11/30/03 20:35:39 Page: 4 **
Title : Yankee Rowe DCGL Am-241 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Am-241-DCGL_Build_nov28.bld Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00[m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
AM-241 1.000E+00 3.640E-03 4.440E-01 9.570E-05 NP-237 0.000E+00 4.440E-03 5.400E-01 1.210E-03 U-233 0.000E+00 2.890E-04 1.350E-01 1.910E-06 TH-229 0.000E+00 4.030E-03 2.160E+00 1.720E-03 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
AM-241 1.000E+00 3.640E-03 4.440E-01 9.570E-05 NP-237 0.000E+00 4.440E-03 5.400E-01 1.210E-03
- RESRAD-BUILD Program Output, Version 3.21 11/30/03 20:35:39 Page: 5 **
Title : Yankee Rowe DCGL Am-241 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Am-241-DCGL_Build_nov28.bld U-233 0.000E+00 2.890E-04 1.350E-01 1.910E-06 TH-229 0.000E+00 4.030E-03 2.160E+00 1.720E-03 Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
AM-241 1.000E+00 3.640E-03 4.440E-01 9.570E-05 NP-237 0.000E+00 4.440E-03 5.400E-01 1.210E-03 U-233 0.000E+00 2.890E-04 1.350E-01 1.910E-06 TH-229 0.000E+00 4.030E-03 2.160E+00 1.720E-03 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
AM-241 1.000E+00 3.640E-03 4.440E-01 9.570E-05 NP-237 0.000E+00 4.440E-03 5.400E-01 1.210E-03 U-233 0.000E+00 2.890E-04 1.350E-01 1.910E-06
- RESRAD-BUILD Program Output, Version 3.21 11/30/03 20:35:39 Page: 6 **
Title : Yankee Rowe DCGL Am-241 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Am-241-DCGL_Build_nov28.bld TH-229 0.000E+00 4.030E-03 2.160E+00 1.720E-03 Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
AM-241 1.000E+00 3.640E-03 4.440E-01 9.570E-05 NP-237 0.000E+00 4.440E-03 5.400E-01 1.210E-03 U-233 0.000E+00 2.890E-04 1.350E-01 1.910E-06 TH-229 0.000E+00 4.030E-03 2.160E+00 1.720E-03
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 11:28:05 Page: 2 **
Title : Yankee Rowe DCGL C-14 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\C-14-DCGL_Build_nov28.bld RESRAD-BUILD Input Parameters Number of Sources : 5 Number of Receptors: 1 Total Time : 3.652500E+02 days Fraction Inside : 2.670000E-01 Receptor Information Receptor Room x y z FracTime Inhalation Ingestion(Dust)
[m] [m] [m] [m3/day] [m2/hr]
1 1 2.220 2.220 1.000 1.000 3.36E+01 0.00E+00 Receptor-Source Shielding Relationship Receptor Source Density Thickness Material
[g/cm3] [cm]
1 1 2.40E+00 0.00E+00 Concrete 1 2 2.40E+00 0.00E+00 Concrete 1 3 2.40E+00 0.00E+00 Concrete 1 4 2.40E+00 0.00E+00 Concrete 1 5 2.40E+00 0.00E+00 Concrete
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 11:28:05 Page: 3 **
Title : Yankee Rowe DCGL C-14 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\C-14-DCGL_Build_nov28.bld Building Information Building Air Exchange Rate: 1.52E+00 1/hr Height[m] Air Exchanges [m3/hr]
Area [m2]
- <=Q01: 1.05E+02 H1: 3.510
- Room 1
- Q10 : 1.05E+02
- LAMBDA: 1.52E+00
- Area 19.710 *
- Deposition velocity: 8.53E-05 [m/s] Resuspension Rate: 1.83E-08 [1/s]
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 11:28:05 Page: 4 **
Title : Yankee Rowe DCGL C-14 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\C-14-DCGL_Build_nov28.bld Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00[m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
C-14 1.000E+00 2.090E-06 2.090E-06 2.620E-08 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
C-14 1.000E+00 2.090E-06 2.090E-06 2.620E-08
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 11:28:05 Page: 5 **
Title : Yankee Rowe DCGL C-14 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\C-14-DCGL_Build_nov28.bld Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
C-14 1.000E+00 2.090E-06 2.090E-06 2.620E-08 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
C-14 1.000E+00 2.090E-06 2.090E-06 2.620E-08
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 11:28:05 Page: 6 **
Title : Yankee Rowe DCGL C-14 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\C-14-DCGL_Build_nov28.bld Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
C-14 1.000E+00 2.090E-06 2.090E-06 2.620E-08
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 12:48:27 Page: 2 **
Title : Yankee Rowe DCGL Cm-243 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Cm-243-DCGL_Build_nov28.bld RESRAD-BUILD Input Parameters Number of Sources : 5 Number of Receptors: 1 Total Time : 3.652500E+02 days Fraction Inside : 2.670000E-01 Receptor Information Receptor Room x y z FracTime Inhalation Ingestion(Dust)
[m] [m] [m] [m3/day] [m2/hr]
1 1 2.220 2.220 1.000 1.000 3.36E+01 0.00E+00 Receptor-Source Shielding Relationship Receptor Source Density Thickness Material
[g/cm3] [cm]
1 1 2.40E+00 0.00E+00 Concrete 1 2 2.40E+00 0.00E+00 Concrete 1 3 2.40E+00 0.00E+00 Concrete 1 4 2.40E+00 0.00E+00 Concrete 1 5 2.40E+00 0.00E+00 Concrete
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 12:48:27 Page: 3 **
Title : Yankee Rowe DCGL Cm-243 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Cm-243-DCGL_Build_nov28.bld Building Information Building Air Exchange Rate: 1.52E+00 1/hr Height[m] Air Exchanges [m3/hr]
Area [m2]
- <=Q01: 1.05E+02 H1: 3.510
- Room 1
- Q10 : 1.05E+02
- LAMBDA: 1.52E+00
- Area 19.710 *
- Deposition velocity: 1.51E-05 [m/s] Resuspension Rate: 1.02E-06 [1/s]
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 12:48:27 Page: 4 **
Title : Yankee Rowe DCGL Cm-243 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Cm-243-DCGL_Build_nov28.bld Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00[m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
CM-243 1.000E+00 2.510E-03 3.070E-01 6.880E-04 PU-239 0.000E+00 3.540E-03 4.290E-01 4.960E-07 U-235 0.000E+00 2.670E-04 1.230E-01 9.030E-04 PA-231 0.000E+00 1.060E-02 1.280E+00 2.010E-04 AC-227 0.000E+00 1.480E-02 6.720E+00 2.160E-03 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
CM-243 1.000E+00 2.510E-03 3.070E-01 6.880E-04
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 12:48:27 Page: 5 **
Title : Yankee Rowe DCGL Cm-243 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Cm-243-DCGL_Build_nov28.bld PU-239 0.000E+00 3.540E-03 4.290E-01 4.960E-07 U-235 0.000E+00 2.670E-04 1.230E-01 9.030E-04 PA-231 0.000E+00 1.060E-02 1.280E+00 2.010E-04 AC-227 0.000E+00 1.480E-02 6.720E+00 2.160E-03 Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
CM-243 1.000E+00 2.510E-03 3.070E-01 6.880E-04 PU-239 0.000E+00 3.540E-03 4.290E-01 4.960E-07 U-235 0.000E+00 2.670E-04 1.230E-01 9.030E-04 PA-231 0.000E+00 1.060E-02 1.280E+00 2.010E-04 AC-227 0.000E+00 1.480E-02 6.720E+00 2.160E-03 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 12:48:27 Page: 6 **
Title : Yankee Rowe DCGL Cm-243 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Cm-243-DCGL_Build_nov28.bld CM-243 1.000E+00 2.510E-03 3.070E-01 6.880E-04 PU-239 0.000E+00 3.540E-03 4.290E-01 4.960E-07 U-235 0.000E+00 2.670E-04 1.230E-01 9.030E-04 PA-231 0.000E+00 1.060E-02 1.280E+00 2.010E-04 AC-227 0.000E+00 1.480E-02 6.720E+00 2.160E-03 Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
CM-243 1.000E+00 2.510E-03 3.070E-01 6.880E-04 PU-239 0.000E+00 3.540E-03 4.290E-01 4.960E-07 U-235 0.000E+00 2.670E-04 1.230E-01 9.030E-04 PA-231 0.000E+00 1.060E-02 1.280E+00 2.010E-04 AC-227 0.000E+00 1.480E-02 6.720E+00 2.160E-03
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 12:48:27 Page: 7 **
Title : Yankee Rowe DCGL Cm-243 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Cm-243-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years Assessment for Time: 1 Time =0.00E+00 yr Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00 [m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
CM-243 1.000E+00 PU-239 0.000E+00 U-235 0.000E+00 PA-231 0.000E+00 AC-227 0.000E+00 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
CM-243 1.000E+00 PU-239 0.000E+00 U-235 0.000E+00 PA-231 0.000E+00 AC-227 0.000E+00
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 12:48:27 Page: 8 **
Title : Yankee Rowe DCGL Cm-243 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Cm-243-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
CM-243 1.000E+00 PU-239 0.000E+00 U-235 0.000E+00 PA-231 0.000E+00 AC-227 0.000E+00 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
CM-243 1.000E+00 PU-239 0.000E+00 U-235 0.000E+00 PA-231 0.000E+00 AC-227 0.000E+00
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 12:48:27 Page: 9 **
Title : Yankee Rowe DCGL Cm-243 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Cm-243-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
CM-243 1.000E+00 PU-239 0.000E+00 U-235 0.000E+00 PA-231 0.000E+00 AC-227 0.000E+00
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 12:48:27 Page: 10 **
Title : Yankee Rowe DCGL Cm-243 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Cm-243-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years RESRAD-BUILDDose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Total 1 2 3 4 5 Receptor 1 1.89E-05 1.46E-05 1.46E-05 1.46E-05 1.46E-05 7.73E-05 Total 1.89E-05 1.46E-05 1.46E-05 1.46E-05 1.46E-05 7.73E-05
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:25:11 Page: 2 **
Title : Yankee Rowe DCGL Co-60 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Co-60-DCGL_Build_nov28.bld RESRAD-BUILD Input Parameters Number of Sources : 5 Number of Receptors: 1 Total Time : 3.652500E+02 days Fraction Inside : 2.670000E-01 Receptor Information Receptor Room x y z FracTime Inhalation Ingestion(Dust)
[m] [m] [m] [m3/day] [m2/hr]
1 1 2.220 2.220 1.000 1.000 3.36E+01 0.00E+00 Receptor-Source Shielding Relationship Receptor Source Density Thickness Material
[g/cm3] [cm]
1 1 2.40E+00 0.00E+00 Concrete 1 2 2.40E+00 0.00E+00 Concrete 1 3 2.40E+00 0.00E+00 Concrete 1 4 2.40E+00 0.00E+00 Concrete 1 5 2.40E+00 0.00E+00 Concrete
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:25:11 Page: 3 **
Title : Yankee Rowe DCGL Co-60 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Co-60-DCGL_Build_nov28.bld Building Information Building Air Exchange Rate: 1.52E+00 1/hr Height[m] Air Exchanges [m3/hr]
Area [m2]
- <=Q01: 1.05E+02 H1: 3.510
- Room 1
- Q10 : 1.05E+02
- LAMBDA: 1.52E+00
- Area 19.710 *
- Deposition velocity: 4.79E-04 [m/s] Resuspension Rate: 6.75E-10 [1/s]
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:25:11 Page: 4 **
Title : Yankee Rowe DCGL Co-60 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Co-60-DCGL_Build_nov28.bld Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00[m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
CO-60 1.000E+00 2.690E-05 2.190E-04 1.470E-02 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
CO-60 1.000E+00 2.690E-05 2.190E-04 1.470E-02
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:25:11 Page: 5 **
Title : Yankee Rowe DCGL Co-60 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Co-60-DCGL_Build_nov28.bld Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
CO-60 1.000E+00 2.690E-05 2.190E-04 1.470E-02 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
CO-60 1.000E+00 2.690E-05 2.190E-04 1.470E-02
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:25:11 Page: 6 **
Title : Yankee Rowe DCGL Co-60 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Co-60-DCGL_Build_nov28.bld Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
CO-60 1.000E+00 2.690E-05 2.190E-04 1.470E-02
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:25:11 Page: 7 **
Title : Yankee Rowe DCGL Co-60 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Co-60-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years Assessment for Time: 1 Time =0.00E+00 yr Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00 [m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
CO-60 1.000E+00 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
CO-60 1.000E+00
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:25:11 Page: 8 **
Title : Yankee Rowe DCGL Co-60 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Co-60-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
CO-60 1.000E+00 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
CO-60 1.000E+00 Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
CO-60 1.000E+00
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:25:11 Page: 9 **
Title : Yankee Rowe DCGL Co-60 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Co-60-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years RESRAD-BUILDDose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Total 1 2 3 4 5 Receptor 1 1.30E-05 4.42E-06 4.42E-06 4.42E-06 4.42E-06 3.07E-05 Total 1.30E-05 4.42E-06 4.42E-06 4.42E-06 4.42E-06 3.07E-05
- RESRAD-BUILD Program Output, Version 3.21 12/17/03 08:15:08 Page: 2 **
Title : Yankee Rowe DCGL Cs-134 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Cs-134-DCGL_Build_nov28.bld RESRAD-BUILD Input Parameters Number of Sources : 5 Number of Receptors: 1 Total Time : 3.652500E+02 days Fraction Inside : 2.670000E-01 Receptor Information Receptor Room x y z FracTime Inhalation Ingestion(Dust)
[m] [m] [m] [m3/day] [m2/hr]
1 1 2.220 2.220 1.000 1.000 3.36E+01 0.00E+00 Receptor-Source Shielding Relationship Receptor Source Density Thickness Material
[g/cm3] [cm]
1 1 2.40E+00 0.00E+00 Concrete 1 2 2.40E+00 0.00E+00 Concrete 1 3 2.40E+00 0.00E+00 Concrete 1 4 2.40E+00 0.00E+00 Concrete 1 5 2.40E+00 0.00E+00 Concrete
- RESRAD-BUILD Program Output, Version 3.21 12/17/03 08:15:08 Page: 3 **
Title : Yankee Rowe DCGL Cs-134 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Cs-134-DCGL_Build_nov28.bld Building Information Building Air Exchange Rate: 1.52E+00 1/hr Height[m] Air Exchanges [m3/hr]
Area [m2]
- <=Q01: 1.05E+02 H1: 3.510
- Room 1
- Q10 : 1.05E+02
- LAMBDA: 1.52E+00
- Area 19.710 *
- Deposition velocity: 4.79E-04 [m/s] Resuspension Rate: 6.75E-10 [1/s]
- RESRAD-BUILD Program Output, Version 3.21 12/17/03 08:15:08 Page: 4 **
Title : Yankee Rowe DCGL Cs-134 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Cs-134-DCGL_Build_nov28.bld Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00[m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
CS-134 1.000E+00 7.330E-05 4.630E-05 8.860E-03 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
CS-134 1.000E+00 7.330E-05 4.630E-05 8.860E-03
- RESRAD-BUILD Program Output, Version 3.21 12/17/03 08:15:08 Page: 5 **
Title : Yankee Rowe DCGL Cs-134 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Cs-134-DCGL_Build_nov28.bld Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
CS-134 1.000E+00 7.330E-05 4.630E-05 8.860E-03 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
CS-134 1.000E+00 7.330E-05 4.630E-05 8.860E-03
- RESRAD-BUILD Program Output, Version 3.21 12/17/03 08:15:08 Page: 6 **
Title : Yankee Rowe DCGL Cs-134 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Cs-134-DCGL_Build_nov28.bld Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
CS-134 1.000E+00 7.330E-05 4.630E-05 8.860E-03
- RESRAD-BUILD Program Output, Version 3.21 12/17/03 08:15:08 Page: 7 **
Title : Yankee Rowe DCGL Cs-134 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Cs-134-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years Assessment for Time: 1 Time =0.00E+00 yr Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00 [m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
CS-134 1.000E+00 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
CS-134 1.000E+00
- RESRAD-BUILD Program Output, Version 3.21 12/17/03 08:15:08 Page: 8 **
Title : Yankee Rowe DCGL Cs-134 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Cs-134-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
CS-134 1.000E+00 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
CS-134 1.000E+00 Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
CS-134 1.000E+00
- RESRAD-BUILD Program Output, Version 3.21 12/17/03 08:15:08 Page: 9 **
Title : Yankee Rowe DCGL Cs-134 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Cs-134-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years RESRAD-BUILDDose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Total 1 2 3 4 5 Receptor 1 7.97E-06 2.85E-06 2.85E-06 2.85E-06 2.85E-06 1.94E-05 Total 7.97E-06 2.85E-06 2.85E-06 2.85E-06 2.85E-06 1.94E-05
- RESRAD-BUILD Program Output, Version 3.21 12/17/03 08:19:10 Page: 2 **
Title : Yankee Rowe DCGL Cs-137 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Cs-137-DCGL_Build_nov28.bld RESRAD-BUILD Input Parameters Number of Sources : 5 Number of Receptors: 1 Total Time : 3.652500E+02 days Fraction Inside : 2.670000E-01 Receptor Information Receptor Room x y z FracTime Inhalation Ingestion(Dust)
[m] [m] [m] [m3/day] [m2/hr]
1 1 2.220 2.220 1.000 1.000 3.36E+01 0.00E+00 Receptor-Source Shielding Relationship Receptor Source Density Thickness Material
[g/cm3] [cm]
1 1 2.40E+00 0.00E+00 Concrete 1 2 2.40E+00 0.00E+00 Concrete 1 3 2.40E+00 0.00E+00 Concrete 1 4 2.40E+00 0.00E+00 Concrete 1 5 2.40E+00 0.00E+00 Concrete
- RESRAD-BUILD Program Output, Version 3.21 12/17/03 08:19:10 Page: 3 **
Title : Yankee Rowe DCGL Cs-137 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Cs-137-DCGL_Build_nov28.bld Building Information Building Air Exchange Rate: 1.52E+00 1/hr Height[m] Air Exchanges [m3/hr]
Area [m2]
- <=Q01: 1.05E+02 H1: 3.510
- Room 1
- Q10 : 1.05E+02
- LAMBDA: 1.52E+00
- Area 19.710 *
- Deposition velocity: 4.79E-04 [m/s] Resuspension Rate: 6.75E-10 [1/s]
- RESRAD-BUILD Program Output, Version 3.21 12/17/03 08:19:10 Page: 4 **
Title : Yankee Rowe DCGL Cs-137 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Cs-137-DCGL_Build_nov28.bld Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00[m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
CS-137 1.000E+00 5.000E-05 3.190E-05 3.190E-03 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
CS-137 1.000E+00 5.000E-05 3.190E-05 3.190E-03
- RESRAD-BUILD Program Output, Version 3.21 12/17/03 08:19:10 Page: 5 **
Title : Yankee Rowe DCGL Cs-137 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Cs-137-DCGL_Build_nov28.bld Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
CS-137 1.000E+00 5.000E-05 3.190E-05 3.190E-03 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
CS-137 1.000E+00 5.000E-05 3.190E-05 3.190E-03
- RESRAD-BUILD Program Output, Version 3.21 12/17/03 08:19:10 Page: 6 **
Title : Yankee Rowe DCGL Cs-137 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Cs-137-DCGL_Build_nov28.bld Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
CS-137 1.000E+00 5.000E-05 3.190E-05 3.190E-03
- RESRAD-BUILD Program Output, Version 3.21 12/17/03 08:19:10 Page: 7 **
Title : Yankee Rowe DCGL Cs-137 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Cs-137-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years Assessment for Time: 1 Time =0.00E+00 yr Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00 [m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
CS-137 1.000E+00 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
CS-137 1.000E+00
- RESRAD-BUILD Program Output, Version 3.21 12/17/03 08:19:10 Page: 8 **
Title : Yankee Rowe DCGL Cs-137 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Cs-137-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
CS-137 1.000E+00 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
CS-137 1.000E+00 Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
CS-137 1.000E+00
- RESRAD-BUILD Program Output, Version 3.21 12/17/03 08:19:10 Page: 9 **
Title : Yankee Rowe DCGL Cs-137 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Cs-137-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years RESRAD-BUILDDose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Total 1 2 3 4 5 Receptor 1 3.53E-06 1.32E-06 1.32E-06 1.32E-06 1.32E-06 8.82E-06 Total 3.53E-06 1.32E-06 1.32E-06 1.32E-06 1.32E-06 8.82E-06
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 12:40:21 Page: 2 **
Title : Yankee Rowe DCGL Eu-152 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Eu-152-DCGL_Build_nov28.bld RESRAD-BUILD Input Parameters Number of Sources : 5 Number of Receptors: 1 Total Time : 3.652500E+02 days Fraction Inside : 2.670000E-01 Receptor Information Receptor Room x y z FracTime Inhalation Ingestion(Dust)
[m] [m] [m] [m3/day] [m2/hr]
1 1 2.220 2.220 1.000 1.000 3.36E+01 0.00E+00 Receptor-Source Shielding Relationship Receptor Source Density Thickness Material
[g/cm3] [cm]
1 1 2.40E+00 0.00E+00 Concrete 1 2 2.40E+00 0.00E+00 Concrete 1 3 2.40E+00 0.00E+00 Concrete 1 4 2.40E+00 0.00E+00 Concrete 1 5 2.40E+00 0.00E+00 Concrete
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 12:40:21 Page: 3 **
Title : Yankee Rowe DCGL Eu-152 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Eu-152-DCGL_Build_nov28.bld Building Information Building Air Exchange Rate: 1.52E+00 1/hr Height[m] Air Exchanges [m3/hr]
Area [m2]
- <=Q01: 1.05E+02 H1: 3.510
- Room 1
- Q10 : 1.05E+02
- LAMBDA: 1.52E+00
- Area 19.710 *
- Deposition velocity: 8.53E-05 [m/s] Resuspension Rate: 1.83E-08 [1/s]
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 12:40:21 Page: 4 **
Title : Yankee Rowe DCGL Eu-152 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Eu-152-DCGL_Build_nov28.bld Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00[m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
GD-152 0.000E+00 1.610E-04 2.430E-01 0.000E+00 EU-152 1.000E+00 6.480E-06 2.210E-04 6.610E-03 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
GD-152 0.000E+00 1.610E-04 2.430E-01 0.000E+00 EU-152 1.000E+00 6.480E-06 2.210E-04 6.610E-03
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 12:40:21 Page: 5 **
Title : Yankee Rowe DCGL Eu-152 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Eu-152-DCGL_Build_nov28.bld Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
GD-152 0.000E+00 1.610E-04 2.430E-01 0.000E+00 EU-152 1.000E+00 6.480E-06 2.210E-04 6.610E-03 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
GD-152 0.000E+00 1.610E-04 2.430E-01 0.000E+00 EU-152 1.000E+00 6.480E-06 2.210E-04 6.610E-03
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 12:40:21 Page: 6 **
Title : Yankee Rowe DCGL Eu-152 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Eu-152-DCGL_Build_nov28.bld Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
GD-152 0.000E+00 1.610E-04 2.430E-01 0.000E+00 EU-152 1.000E+00 6.480E-06 2.210E-04 6.610E-03
- RESRAD-BUILD Program Output, Version 3.21 12/17/03 08:22:30 Page: 2 **
Title : Yankee Rowe DCGL Eu-154 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Eu-154-DCGL_Build_nov28.bld RESRAD-BUILD Input Parameters Number of Sources : 5 Number of Receptors: 1 Total Time : 3.652500E+02 days Fraction Inside : 2.670000E-01 Receptor Information Receptor Room x y z FracTime Inhalation Ingestion(Dust)
[m] [m] [m] [m3/day] [m2/hr]
1 1 2.220 2.220 1.000 1.000 3.36E+01 0.00E+00 Receptor-Source Shielding Relationship Receptor Source Density Thickness Material
[g/cm3] [cm]
1 1 2.40E+00 0.00E+00 Concrete 1 2 2.40E+00 0.00E+00 Concrete 1 3 2.40E+00 0.00E+00 Concrete 1 4 2.40E+00 0.00E+00 Concrete 1 5 2.40E+00 0.00E+00 Concrete
- RESRAD-BUILD Program Output, Version 3.21 12/17/03 08:22:30 Page: 3 **
Title : Yankee Rowe DCGL Eu-154 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Eu-154-DCGL_Build_nov28.bld Building Information Building Air Exchange Rate: 1.52E+00 1/hr Height[m] Air Exchanges [m3/hr]
Area [m2]
- <=Q01: 1.05E+02 H1: 3.510
- Room 1
- Q10 : 1.05E+02
- LAMBDA: 1.52E+00
- Area 19.710 *
- Deposition velocity: 4.79E-04 [m/s] Resuspension Rate: 6.75E-10 [1/s]
- RESRAD-BUILD Program Output, Version 3.21 12/17/03 08:22:30 Page: 4 **
Title : Yankee Rowe DCGL Eu-154 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Eu-154-DCGL_Build_nov28.bld Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00[m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
EU-154 1.000E+00 9.550E-06 2.860E-04 7.180E-03 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
EU-154 1.000E+00 9.550E-06 2.860E-04 7.180E-03
- RESRAD-BUILD Program Output, Version 3.21 12/17/03 08:22:30 Page: 5 **
Title : Yankee Rowe DCGL Eu-154 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Eu-154-DCGL_Build_nov28.bld Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
EU-154 1.000E+00 9.550E-06 2.860E-04 7.180E-03 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
EU-154 1.000E+00 9.550E-06 2.860E-04 7.180E-03
- RESRAD-BUILD Program Output, Version 3.21 12/17/03 08:22:30 Page: 6 **
Title : Yankee Rowe DCGL Eu-154 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Eu-154-DCGL_Build_nov28.bld Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
EU-154 1.000E+00 9.550E-06 2.860E-04 7.180E-03
- RESRAD-BUILD Program Output, Version 3.21 12/17/03 08:22:30 Page: 7 **
Title : Yankee Rowe DCGL Eu-154 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Eu-154-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years Assessment for Time: 1 Time =0.00E+00 yr Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00 [m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
EU-154 1.000E+00 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
EU-154 1.000E+00
- RESRAD-BUILD Program Output, Version 3.21 12/17/03 08:22:30 Page: 8 **
Title : Yankee Rowe DCGL Eu-154 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Eu-154-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
EU-154 1.000E+00 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
EU-154 1.000E+00 Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
EU-154 1.000E+00
- RESRAD-BUILD Program Output, Version 3.21 12/17/03 08:22:30 Page: 9 **
Title : Yankee Rowe DCGL Eu-154 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Eu-154-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years RESRAD-BUILDDose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Total 1 2 3 4 5 Receptor 1 6.82E-06 2.32E-06 2.32E-06 2.32E-06 2.32E-06 1.61E-05 Total 6.82E-06 2.32E-06 2.32E-06 2.32E-06 2.32E-06 1.61E-05
- RESRAD-BUILD Program Output, Version 3.21 11/29/03 14:14:09 Page: 2 **
Title : Yankee Rowe DCGL Eu-155 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Eu-155-DCGL_Build_nov28.bld RESRAD-BUILD Input Parameters Number of Sources : 5 Number of Receptors: 1 Total Time : 3.652500E+02 days Fraction Inside : 2.670000E-01 Receptor Information Receptor Room x y z FracTime Inhalation Ingestion(Dust)
[m] [m] [m] [m3/day] [m2/hr]
1 1 2.220 2.220 1.000 1.000 3.36E+01 0.00E+00 Receptor-Source Shielding Relationship Receptor Source Density Thickness Material
[g/cm3] [cm]
1 1 2.40E+00 0.00E+00 Concrete 1 2 2.40E+00 0.00E+00 Concrete 1 3 2.40E+00 0.00E+00 Concrete 1 4 2.40E+00 0.00E+00 Concrete 1 5 2.40E+00 0.00E+00 Concrete
- RESRAD-BUILD Program Output, Version 3.21 11/29/03 14:14:09 Page: 3 **
Title : Yankee Rowe DCGL Eu-155 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Eu-155-DCGL_Build_nov28.bld Building Information Building Air Exchange Rate: 1.52E+00 1/hr Height[m] Air Exchanges [m3/hr]
Area [m2]
- <=Q01: 1.05E+02 H1: 3.510
- Room 1
- Q10 : 1.05E+02
- LAMBDA: 1.52E+00
- Area 19.710 *
- Deposition velocity: 8.53E-05 [m/s] Resuspension Rate: 1.83E-08 [1/s]
- RESRAD-BUILD Program Output, Version 3.21 11/29/03 14:14:09 Page: 4 **
Title : Yankee Rowe DCGL Eu-155 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Eu-155-DCGL_Build_nov28.bld Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00[m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
EU-155 1.000E+00 1.530E-06 4.140E-05 2.910E-04 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
EU-155 1.000E+00 1.530E-06 4.140E-05 2.910E-04
- RESRAD-BUILD Program Output, Version 3.21 11/29/03 14:14:09 Page: 5 **
Title : Yankee Rowe DCGL Eu-155 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Eu-155-DCGL_Build_nov28.bld Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
EU-155 1.000E+00 1.530E-06 4.140E-05 2.910E-04 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
EU-155 1.000E+00 1.530E-06 4.140E-05 2.910E-04
- RESRAD-BUILD Program Output, Version 3.21 11/29/03 14:14:09 Page: 6 **
Title : Yankee Rowe DCGL Eu-155 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Eu-155-DCGL_Build_nov28.bld Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
EU-155 1.000E+00 1.530E-06 4.140E-05 2.910E-04
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:19:06 Page: 2 **
Title : Yankee Rowe DCGL Fe-55 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Fe-55-DCGL_Build_nov28.bld RESRAD-BUILD Input Parameters Number of Sources : 5 Number of Receptors: 1 Total Time : 3.652500E+02 days Fraction Inside : 2.670000E-01 Receptor Information Receptor Room x y z FracTime Inhalation Ingestion(Dust)
[m] [m] [m] [m3/day] [m2/hr]
1 1 2.220 2.220 1.000 1.000 3.36E+01 0.00E+00 Receptor-Source Shielding Relationship Receptor Source Density Thickness Material
[g/cm3] [cm]
1 1 2.40E+00 0.00E+00 Concrete 1 2 2.40E+00 0.00E+00 Concrete 1 3 2.40E+00 0.00E+00 Concrete 1 4 2.40E+00 0.00E+00 Concrete 1 5 2.40E+00 0.00E+00 Concrete
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:19:06 Page: 3 **
Title : Yankee Rowe DCGL Fe-55 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Fe-55-DCGL_Build_nov28.bld Building Information Building Air Exchange Rate: 1.52E+00 1/hr Height[m] Air Exchanges [m3/hr]
Area [m2]
- <=Q01: 1.05E+02 H1: 3.510
- Room 1
- Q10 : 1.05E+02
- LAMBDA: 1.52E+00
- Area 19.710 *
- Deposition velocity: 1.51E-05 [m/s] Resuspension Rate: 1.02E-06 [1/s]
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:19:06 Page: 4 **
Title : Yankee Rowe DCGL Fe-55 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Fe-55-DCGL_Build_nov28.bld Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00[m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
FE-55 1.000E+00 6.070E-07 2.690E-06 0.000E+00 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
FE-55 1.000E+00 6.070E-07 2.690E-06 0.000E+00
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:19:06 Page: 5 **
Title : Yankee Rowe DCGL Fe-55 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Fe-55-DCGL_Build_nov28.bld Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
FE-55 1.000E+00 6.070E-07 2.690E-06 0.000E+00 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
FE-55 1.000E+00 6.070E-07 2.690E-06 0.000E+00
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:19:06 Page: 6 **
Title : Yankee Rowe DCGL Fe-55 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Fe-55-DCGL_Build_nov28.bld Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
FE-55 1.000E+00 6.070E-07 2.690E-06 0.000E+00
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:19:06 Page: 7 **
Title : Yankee Rowe DCGL Fe-55 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Fe-55-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years Assessment for Time: 1 Time =0.00E+00 yr Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00 [m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
FE-55 1.000E+00 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
FE-55 1.000E+00
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:19:06 Page: 8 **
Title : Yankee Rowe DCGL Fe-55 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Fe-55-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
FE-55 1.000E+00 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
FE-55 1.000E+00 Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
FE-55 1.000E+00
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:19:06 Page: 9 **
Title : Yankee Rowe DCGL Fe-55 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Fe-55-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years RESRAD-BUILDDose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Total 1 2 3 4 5 Receptor 1 3.31E-09 2.61E-09 2.61E-09 2.61E-09 2.61E-09 1.38E-08 Total 3.31E-09 2.61E-09 2.61E-09 2.61E-09 2.61E-09 1.38E-08
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 09:48:15 Page: 2 **
Title : Yankee Rowe DCGL H-3 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\H-3-DCGL_Build_nov28.bld RESRAD-BUILD Input Parameters Number of Sources : 5 Number of Receptors: 1 Total Time : 3.652500E+02 days Fraction Inside : 2.670000E-01 Receptor Information Receptor Room x y z FracTime Inhalation Ingestion(Dust)
[m] [m] [m] [m3/day] [m2/hr]
1 1 2.220 2.220 1.000 1.000 3.36E+01 0.00E+00 Receptor-Source Shielding Relationship Receptor Source Density Thickness Material
[g/cm3] [cm]
1 1 2.40E+00 0.00E+00 Concrete 1 2 2.40E+00 0.00E+00 Concrete 1 3 2.40E+00 0.00E+00 Concrete 1 4 2.40E+00 0.00E+00 Concrete 1 5 2.40E+00 0.00E+00 Concrete
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 09:48:15 Page: 3 **
Title : Yankee Rowe DCGL H-3 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\H-3-DCGL_Build_nov28.bld Building Information Building Air Exchange Rate: 1.52E+00 1/hr Height[m] Air Exchanges [m3/hr]
Area [m2]
- <=Q01: 1.05E+02 H1: 3.510
- Room 1
- Q10 : 1.05E+02
- LAMBDA: 1.52E+00
- Area 19.710 *
- Deposition velocity: 1.51E-05 [m/s] Resuspension Rate: 1.02E-06 [1/s]
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 09:48:15 Page: 4 **
Title : Yankee Rowe DCGL H-3 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\H-3-DCGL_Build_nov28.bld Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00[m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 1.000E+00 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
H-3 1.000E+00 6.400E-08 6.400E-08 0.000E+00 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 1.000E+00 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
H-3 1.000E+00 6.400E-08 6.400E-08 0.000E+00
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 09:48:15 Page: 5 **
Title : Yankee Rowe DCGL H-3 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\H-3-DCGL_Build_nov28.bld Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 1.000E+00 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
H-3 1.000E+00 6.400E-08 6.400E-08 0.000E+00 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 1.000E+00 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
H-3 1.000E+00 6.400E-08 6.400E-08 0.000E+00
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 09:48:15 Page: 6 **
Title : Yankee Rowe DCGL H-3 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\H-3-DCGL_Build_nov28.bld Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 1.000E+00 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
H-3 1.000E+00 6.400E-08 6.400E-08 0.000E+00
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 09:48:15 Page: 7 **
Title : Yankee Rowe DCGL H-3 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\H-3-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years Assessment for Time: 1 Time =0.00E+00 yr Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00 [m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 1.000E+00 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
H-3 1.000E+00 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 1.000E+00 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
H-3 1.000E+00
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 09:48:15 Page: 8 **
Title : Yankee Rowe DCGL H-3 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\H-3-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 1.000E+00 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
H-3 1.000E+00 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 1.000E+00 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
H-3 1.000E+00 Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 1.000E+00 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
H-3 1.000E+00
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 09:48:15 Page: 9 **
Title : Yankee Rowe DCGL H-3 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\H-3-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years RESRAD-BUILDDose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Total 1 2 3 4 5 Receptor 1 3.94E-10 3.11E-10 3.11E-10 3.11E-10 3.11E-10 1.64E-09 Total 3.94E-10 3.11E-10 3.11E-10 3.11E-10 3.11E-10 1.64E-09
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:39:42 Page: 2 **
Title : Yankee Rowe DCGL Nb-94 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Nb-94-DCGL_Build_nov28.bld RESRAD-BUILD Input Parameters Number of Sources : 5 Number of Receptors: 1 Total Time : 3.652500E+02 days Fraction Inside : 2.670000E-01 Receptor Information Receptor Room x y z FracTime Inhalation Ingestion(Dust)
[m] [m] [m] [m3/day] [m2/hr]
1 1 2.220 2.220 1.000 1.000 3.36E+01 0.00E+00 Receptor-Source Shielding Relationship Receptor Source Density Thickness Material
[g/cm3] [cm]
1 1 2.40E+00 0.00E+00 Concrete 1 2 2.40E+00 0.00E+00 Concrete 1 3 2.40E+00 0.00E+00 Concrete 1 4 2.40E+00 0.00E+00 Concrete 1 5 2.40E+00 0.00E+00 Concrete
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:39:42 Page: 3 **
Title : Yankee Rowe DCGL Nb-94 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Nb-94-DCGL_Build_nov28.bld Building Information Building Air Exchange Rate: 1.52E+00 1/hr Height[m] Air Exchanges [m3/hr]
Area [m2]
- <=Q01: 1.05E+02 H1: 3.510
- Room 1
- Q10 : 1.05E+02
- LAMBDA: 1.52E+00
- Area 19.710 *
- Deposition velocity: 4.79E-04 [m/s] Resuspension Rate: 6.75E-10 [1/s]
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:39:42 Page: 4 **
Title : Yankee Rowe DCGL Nb-94 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Nb-94-DCGL_Build_nov28.bld Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00[m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
NB-94 1.000E+00 7.140E-06 4.140E-04 9.010E-03 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
NB-94 1.000E+00 7.140E-06 4.140E-04 9.010E-03
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:39:42 Page: 5 **
Title : Yankee Rowe DCGL Nb-94 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Nb-94-DCGL_Build_nov28.bld Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
NB-94 1.000E+00 7.140E-06 4.140E-04 9.010E-03 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
NB-94 1.000E+00 7.140E-06 4.140E-04 9.010E-03
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:39:42 Page: 6 **
Title : Yankee Rowe DCGL Nb-94 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Nb-94-DCGL_Build_nov28.bld Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
NB-94 1.000E+00 7.140E-06 4.140E-04 9.010E-03
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:39:42 Page: 7 **
Title : Yankee Rowe DCGL Nb-94 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Nb-94-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years Assessment for Time: 1 Time =0.00E+00 yr Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00 [m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
NB-94 1.000E+00 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
NB-94 1.000E+00
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:39:42 Page: 8 **
Title : Yankee Rowe DCGL Nb-94 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Nb-94-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
NB-94 1.000E+00 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
NB-94 1.000E+00 Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
NB-94 1.000E+00
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:39:42 Page: 9 **
Title : Yankee Rowe DCGL Nb-94 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Nb-94-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years RESRAD-BUILDDose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Total 1 2 3 4 5 Receptor 1 9.09E-06 3.07E-06 3.07E-06 3.07E-06 3.07E-06 2.14E-05 Total 9.09E-06 3.07E-06 3.07E-06 3.07E-06 3.07E-06 2.14E-05
- RESRAD-BUILD Program Output, Version 3.21 11/29/03 14:19:37 Page: 2 **
Title : Yankee Rowe DCGL Ni-63 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Ni-63-DCGL_Build_nov28.bld RESRAD-BUILD Input Parameters Number of Sources : 5 Number of Receptors: 1 Total Time : 3.652500E+02 days Fraction Inside : 2.670000E-01 Receptor Information Receptor Room x y z FracTime Inhalation Ingestion(Dust)
[m] [m] [m] [m3/day] [m2/hr]
1 1 2.220 2.220 1.000 1.000 3.36E+01 0.00E+00 Receptor-Source Shielding Relationship Receptor Source Density Thickness Material
[g/cm3] [cm]
1 1 2.40E+00 0.00E+00 Concrete 1 2 2.40E+00 0.00E+00 Concrete 1 3 2.40E+00 0.00E+00 Concrete 1 4 2.40E+00 0.00E+00 Concrete 1 5 2.40E+00 0.00E+00 Concrete
- RESRAD-BUILD Program Output, Version 3.21 11/29/03 14:19:37 Page: 3 **
Title : Yankee Rowe DCGL Ni-63 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Ni-63-DCGL_Build_nov28.bld Building Information Building Air Exchange Rate: 1.52E+00 1/hr Height[m] Air Exchanges [m3/hr]
Area [m2]
- <=Q01: 1.05E+02 H1: 3.510
- Room 1
- Q10 : 1.05E+02
- LAMBDA: 1.52E+00
- Area 19.710 *
- Deposition velocity: 8.53E-05 [m/s] Resuspension Rate: 1.02E-06 [1/s]
- RESRAD-BUILD Program Output, Version 3.21 11/29/03 14:19:37 Page: 4 **
Title : Yankee Rowe DCGL Ni-63 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Ni-63-DCGL_Build_nov28.bld Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00[m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
NI-63 1.000E+00 5.770E-07 6.290E-06 0.000E+00 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
NI-63 1.000E+00 5.770E-07 6.290E-06 0.000E+00
- RESRAD-BUILD Program Output, Version 3.21 11/29/03 14:19:37 Page: 5 **
Title : Yankee Rowe DCGL Ni-63 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Ni-63-DCGL_Build_nov28.bld Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
NI-63 1.000E+00 5.770E-07 6.290E-06 0.000E+00 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
NI-63 1.000E+00 5.770E-07 6.290E-06 0.000E+00
- RESRAD-BUILD Program Output, Version 3.21 11/29/03 14:19:37 Page: 6 **
Title : Yankee Rowe DCGL Ni-63 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Ni-63-DCGL_Build_nov28.bld Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
NI-63 1.000E+00 5.770E-07 6.290E-06 0.000E+00
- RESRAD-BUILD Program Output, Version 3.21 11/29/03 14:48:45 Page: 2 **
Title : Yankee Rowe DCGL Pu-238 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Pu-238-DCGL_Build_nov28.bld RESRAD-BUILD Input Parameters Number of Sources : 5 Number of Receptors: 1 Total Time : 3.652500E+02 days Fraction Inside : 2.670000E-01 Receptor Information Receptor Room x y z FracTime Inhalation Ingestion(Dust)
[m] [m] [m] [m3/day] [m2/hr]
1 1 2.220 2.220 1.000 1.000 3.36E+01 0.00E+00 Receptor-Source Shielding Relationship Receptor Source Density Thickness Material
[g/cm3] [cm]
1 1 2.40E+00 0.00E+00 Concrete 1 2 2.40E+00 0.00E+00 Concrete 1 3 2.40E+00 0.00E+00 Concrete 1 4 2.40E+00 0.00E+00 Concrete 1 5 2.40E+00 0.00E+00 Concrete
- RESRAD-BUILD Program Output, Version 3.21 11/29/03 14:48:45 Page: 3 **
Title : Yankee Rowe DCGL Pu-238 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Pu-238-DCGL_Build_nov28.bld Building Information Building Air Exchange Rate: 1.52E+00 1/hr Height[m] Air Exchanges [m3/hr]
Area [m2]
- <=Q01: 1.05E+02 H1: 3.510
- Room 1
- Q10 : 1.05E+02
- LAMBDA: 1.52E+00
- Area 19.710 *
- Deposition velocity: 8.53E-05 [m/s] Resuspension Rate: 1.02E-06 [1/s]
- RESRAD-BUILD Program Output, Version 3.21 11/29/03 14:48:45 Page: 4 **
Title : Yankee Rowe DCGL Pu-238 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Pu-238-DCGL_Build_nov28.bld Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00[m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Radon Release Fraction: 1.000E-01 Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
PU-238 1.000E+00 3.200E-03 3.920E-01 5.710E-07 U-234 0.000E+00 2.830E-04 1.320E-01 8.930E-07 TH-230 0.000E+00 5.480E-04 3.260E-01 2.040E-06 RA-226 0.000E+00 1.330E-03 8.600E-03 1.040E-02 PB-210 0.000E+00 7.270E-03 2.320E-02 1.050E-05 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Radon Release Fraction: 1.000E-01 Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
PU-238 1.000E+00 3.200E-03 3.920E-01 5.710E-07
- RESRAD-BUILD Program Output, Version 3.21 11/29/03 14:48:45 Page: 5 **
Title : Yankee Rowe DCGL Pu-238 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Pu-238-DCGL_Build_nov28.bld U-234 0.000E+00 2.830E-04 1.320E-01 8.930E-07 TH-230 0.000E+00 5.480E-04 3.260E-01 2.040E-06 RA-226 0.000E+00 1.330E-03 8.600E-03 1.040E-02 PB-210 0.000E+00 7.270E-03 2.320E-02 1.050E-05 Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Radon Release Fraction: 1.000E-01 Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
PU-238 1.000E+00 3.200E-03 3.920E-01 5.710E-07 U-234 0.000E+00 2.830E-04 1.320E-01 8.930E-07 TH-230 0.000E+00 5.480E-04 3.260E-01 2.040E-06 RA-226 0.000E+00 1.330E-03 8.600E-03 1.040E-02 PB-210 0.000E+00 7.270E-03 2.320E-02 1.050E-05 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Radon Release Fraction: 1.000E-01 Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
- RESRAD-BUILD Program Output, Version 3.21 11/29/03 14:48:45 Page: 6 **
Title : Yankee Rowe DCGL Pu-238 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Pu-238-DCGL_Build_nov28.bld PU-238 1.000E+00 3.200E-03 3.920E-01 5.710E-07 U-234 0.000E+00 2.830E-04 1.320E-01 8.930E-07 TH-230 0.000E+00 5.480E-04 3.260E-01 2.040E-06 RA-226 0.000E+00 1.330E-03 8.600E-03 1.040E-02 PB-210 0.000E+00 7.270E-03 2.320E-02 1.050E-05 Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Radon Release Fraction: 1.000E-01 Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
PU-238 1.000E+00 3.200E-03 3.920E-01 5.710E-07 U-234 0.000E+00 2.830E-04 1.320E-01 8.930E-07 TH-230 0.000E+00 5.480E-04 3.260E-01 2.040E-06 RA-226 0.000E+00 1.330E-03 8.600E-03 1.040E-02 PB-210 0.000E+00 7.270E-03 2.320E-02 1.050E-05
- RESRAD-BUILD Program Output, Version 3.21 11/30/03 09:33:02 Page: 2 **
Title : Yankee Rowe DCGL Pu-239 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Pu-239-DCGL_Build_nov28.bld RESRAD-BUILD Input Parameters Number of Sources : 5 Number of Receptors: 1 Total Time : 3.652500E+02 days Fraction Inside : 2.670000E-01 Receptor Information Receptor Room x y z FracTime Inhalation Ingestion(Dust)
[m] [m] [m] [m3/day] [m2/hr]
1 1 2.220 2.220 1.000 1.000 3.36E+01 0.00E+00 Receptor-Source Shielding Relationship Receptor Source Density Thickness Material
[g/cm3] [cm]
1 1 2.40E+00 0.00E+00 Concrete 1 2 2.40E+00 0.00E+00 Concrete 1 3 2.40E+00 0.00E+00 Concrete 1 4 2.40E+00 0.00E+00 Concrete 1 5 2.40E+00 0.00E+00 Concrete
- RESRAD-BUILD Program Output, Version 3.21 11/30/03 09:33:02 Page: 3 **
Title : Yankee Rowe DCGL Pu-239 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Pu-239-DCGL_Build_nov28.bld Building Information Building Air Exchange Rate: 1.52E+00 1/hr Height[m] Air Exchanges [m3/hr]
Area [m2]
- <=Q01: 1.05E+02 H1: 3.510
- Room 1
- Q10 : 1.05E+02
- LAMBDA: 1.52E+00
- Area 19.710 *
- Deposition velocity: 8.53E-05 [m/s] Resuspension Rate: 1.83E-08 [1/s]
- RESRAD-BUILD Program Output, Version 3.21 11/30/03 09:33:02 Page: 4 **
Title : Yankee Rowe DCGL Pu-239 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Pu-239-DCGL_Build_nov28.bld Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00[m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
PU-239 1.000E+00 3.540E-03 4.290E-01 4.960E-07 U-235 0.000E+00 2.670E-04 1.230E-01 9.030E-04 PA-231 0.000E+00 1.060E-02 1.280E+00 2.010E-04 AC-227 0.000E+00 1.480E-02 6.720E+00 2.160E-03 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
PU-239 1.000E+00 3.540E-03 4.290E-01 4.960E-07 U-235 0.000E+00 2.670E-04 1.230E-01 9.030E-04
- RESRAD-BUILD Program Output, Version 3.21 11/30/03 09:33:02 Page: 5 **
Title : Yankee Rowe DCGL Pu-239 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Pu-239-DCGL_Build_nov28.bld PA-231 0.000E+00 1.060E-02 1.280E+00 2.010E-04 AC-227 0.000E+00 1.480E-02 6.720E+00 2.160E-03 Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
PU-239 1.000E+00 3.540E-03 4.290E-01 4.960E-07 U-235 0.000E+00 2.670E-04 1.230E-01 9.030E-04 PA-231 0.000E+00 1.060E-02 1.280E+00 2.010E-04 AC-227 0.000E+00 1.480E-02 6.720E+00 2.160E-03 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
PU-239 1.000E+00 3.540E-03 4.290E-01 4.960E-07 U-235 0.000E+00 2.670E-04 1.230E-01 9.030E-04 PA-231 0.000E+00 1.060E-02 1.280E+00 2.010E-04
- RESRAD-BUILD Program Output, Version 3.21 11/30/03 09:33:02 Page: 6 **
Title : Yankee Rowe DCGL Pu-239 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Pu-239-DCGL_Build_nov28.bld AC-227 0.000E+00 1.480E-02 6.720E+00 2.160E-03 Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
PU-239 1.000E+00 3.540E-03 4.290E-01 4.960E-07 U-235 0.000E+00 2.670E-04 1.230E-01 9.030E-04 PA-231 0.000E+00 1.060E-02 1.280E+00 2.010E-04 AC-227 0.000E+00 1.480E-02 6.720E+00 2.160E-03
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 12:38:14 Page: 2 **
Title : Yankee Rowe DCGL Pu-241 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Pu-241-DCGL_Build_nov28.bld RESRAD-BUILD Input Parameters Number of Sources : 5 Number of Receptors: 1 Total Time : 3.652500E+02 days Fraction Inside : 2.670000E-01 Receptor Information Receptor Room x y z FracTime Inhalation Ingestion(Dust)
[m] [m] [m] [m3/day] [m2/hr]
1 1 2.220 2.220 1.000 1.000 3.36E+01 0.00E+00 Receptor-Source Shielding Relationship Receptor Source Density Thickness Material
[g/cm3] [cm]
1 1 2.40E+00 0.00E+00 Concrete 1 2 2.40E+00 0.00E+00 Concrete 1 3 2.40E+00 0.00E+00 Concrete 1 4 2.40E+00 0.00E+00 Concrete 1 5 2.40E+00 0.00E+00 Concrete
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 12:38:14 Page: 3 **
Title : Yankee Rowe DCGL Pu-241 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Pu-241-DCGL_Build_nov28.bld Building Information Building Air Exchange Rate: 1.52E+00 1/hr Height[m] Air Exchanges [m3/hr]
Area [m2]
- <=Q01: 1.05E+02 H1: 3.510
- Room 1
- Q10 : 1.05E+02
- LAMBDA: 1.52E+00
- Area 19.710 *
- Deposition velocity: 1.51E-05 [m/s] Resuspension Rate: 1.02E-06 [1/s]
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 12:38:14 Page: 4 **
Title : Yankee Rowe DCGL Pu-241 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Pu-241-DCGL_Build_nov28.bld Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00[m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
PU-241 1.000E+00 6.850E-05 8.250E-03 2.560E-08 AM-241 0.000E+00 3.640E-03 4.440E-01 9.570E-05 NP-237 0.000E+00 4.440E-03 5.400E-01 1.210E-03 U-233 0.000E+00 2.890E-04 1.350E-01 1.910E-06 TH-229 0.000E+00 4.030E-03 2.160E+00 1.720E-03 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
PU-241 1.000E+00 6.850E-05 8.250E-03 2.560E-08
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 12:38:14 Page: 5 **
Title : Yankee Rowe DCGL Pu-241 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Pu-241-DCGL_Build_nov28.bld AM-241 0.000E+00 3.640E-03 4.440E-01 9.570E-05 NP-237 0.000E+00 4.440E-03 5.400E-01 1.210E-03 U-233 0.000E+00 2.890E-04 1.350E-01 1.910E-06 TH-229 0.000E+00 4.030E-03 2.160E+00 1.720E-03 Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
PU-241 1.000E+00 6.850E-05 8.250E-03 2.560E-08 AM-241 0.000E+00 3.640E-03 4.440E-01 9.570E-05 NP-237 0.000E+00 4.440E-03 5.400E-01 1.210E-03 U-233 0.000E+00 2.890E-04 1.350E-01 1.910E-06 TH-229 0.000E+00 4.030E-03 2.160E+00 1.720E-03 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 12:38:14 Page: 6 **
Title : Yankee Rowe DCGL Pu-241 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Pu-241-DCGL_Build_nov28.bld PU-241 1.000E+00 6.850E-05 8.250E-03 2.560E-08 AM-241 0.000E+00 3.640E-03 4.440E-01 9.570E-05 NP-237 0.000E+00 4.440E-03 5.400E-01 1.210E-03 U-233 0.000E+00 2.890E-04 1.350E-01 1.910E-06 TH-229 0.000E+00 4.030E-03 2.160E+00 1.720E-03 Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
PU-241 1.000E+00 6.850E-05 8.250E-03 2.560E-08 AM-241 0.000E+00 3.640E-03 4.440E-01 9.570E-05 NP-237 0.000E+00 4.440E-03 5.400E-01 1.210E-03 U-233 0.000E+00 2.890E-04 1.350E-01 1.910E-06 TH-229 0.000E+00 4.030E-03 2.160E+00 1.720E-03
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 12:38:14 Page: 7 **
Title : Yankee Rowe DCGL Pu-241 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Pu-241-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years Assessment for Time: 1 Time =0.00E+00 yr Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00 [m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
PU-241 1.000E+00 AM-241 0.000E+00 NP-237 0.000E+00 U-233 0.000E+00 TH-229 0.000E+00 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
PU-241 1.000E+00 AM-241 0.000E+00 NP-237 0.000E+00 U-233 0.000E+00 TH-229 0.000E+00
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 12:38:14 Page: 8 **
Title : Yankee Rowe DCGL Pu-241 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Pu-241-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
PU-241 1.000E+00 AM-241 0.000E+00 NP-237 0.000E+00 U-233 0.000E+00 TH-229 0.000E+00 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
PU-241 1.000E+00 AM-241 0.000E+00 NP-237 0.000E+00 U-233 0.000E+00 TH-229 0.000E+00
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 12:38:14 Page: 9 **
Title : Yankee Rowe DCGL Pu-241 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Pu-241-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
PU-241 1.000E+00 AM-241 0.000E+00 NP-237 0.000E+00 U-233 0.000E+00 TH-229 0.000E+00
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 12:38:14 Page: 10 **
Title : Yankee Rowe DCGL Pu-241 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Pu-241-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years RESRAD-BUILDDose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Total 1 2 3 4 5 Receptor 1 5.10E-07 4.03E-07 4.03E-07 4.03E-07 4.03E-07 2.12E-06 Total 5.10E-07 4.03E-07 4.03E-07 4.03E-07 4.03E-07 2.12E-06
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 12:38:14 Page: 14 **
Title : Yankee Rowe DCGL Pu-241 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Pu-241-DCGL_Build_nov28.bld Evaluation Time: 9.00000000 years Assessment for Time: 2 Time =9.00E+00 yr Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00 [m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 8.348E-02 Time to Remove: 1.824E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
PU-241 6.367E-01 AM-241 1.141E-02 NP-237 1.788E-08 U-233 2.432E-13 TH-229 6.258E-17 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 8.348E-02 Time to Remove: 1.824E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
PU-241 6.367E-01 AM-241 1.141E-02 NP-237 1.788E-08 U-233 2.432E-13 TH-229 6.258E-17
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 12:38:14 Page: 15 **
Title : Yankee Rowe DCGL Pu-241 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Pu-241-DCGL_Build_nov28.bld Evaluation Time: 9.00000000 years Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 8.348E-02 Time to Remove: 1.824E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
PU-241 6.367E-01 AM-241 1.141E-02 NP-237 1.788E-08 U-233 2.432E-13 TH-229 6.258E-17 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 8.348E-02 Time to Remove: 1.824E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
PU-241 6.367E-01 AM-241 1.141E-02 NP-237 1.788E-08 U-233 2.432E-13 TH-229 6.258E-17
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 12:38:14 Page: 16 **
Title : Yankee Rowe DCGL Pu-241 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Pu-241-DCGL_Build_nov28.bld Evaluation Time: 9.00000000 years Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 8.348E-02 Time to Remove: 1.824E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
PU-241 6.367E-01 AM-241 1.141E-02 NP-237 1.788E-08 U-233 2.432E-13 TH-229 6.258E-17
- RESRAD-BUILD Program Output, Version 3.21 12/01/03 12:38:14 Page: 17 **
Title : Yankee Rowe DCGL Pu-241 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Pu-241-DCGL_Build_nov28.bld Evaluation Time: 9.00000000 years RESRAD-BUILDDose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Total 1 2 3 4 5 Receptor 1 5.45E-07 4.30E-07 4.30E-07 4.30E-07 4.30E-07 2.26E-06 Total 5.45E-07 4.30E-07 4.30E-07 4.30E-07 4.30E-07 2.26E-06
- RESRAD-BUILD Program Output, Version 3.21 11/29/03 13:47:44 Page: 2 **
Title : Yankee Rowe DCGL Sb-125 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Sb-125-DCGL_Build_nov28.bld RESRAD-BUILD Input Parameters Number of Sources : 5 Number of Receptors: 1 Total Time : 3.652500E+02 days Fraction Inside : 2.670000E-01 Receptor Information Receptor Room x y z FracTime Inhalation Ingestion(Dust)
[m] [m] [m] [m3/day] [m2/hr]
1 1 2.220 2.220 1.000 1.000 3.36E+01 0.00E+00 Receptor-Source Shielding Relationship Receptor Source Density Thickness Material
[g/cm3] [cm]
1 1 2.40E+00 0.00E+00 Concrete 1 2 2.40E+00 0.00E+00 Concrete 1 3 2.40E+00 0.00E+00 Concrete 1 4 2.40E+00 0.00E+00 Concrete 1 5 2.40E+00 0.00E+00 Concrete
- RESRAD-BUILD Program Output, Version 3.21 11/29/03 13:47:44 Page: 3 **
Title : Yankee Rowe DCGL Sb-125 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Sb-125-DCGL_Build_nov28.bld Building Information Building Air Exchange Rate: 1.52E+00 1/hr Height[m] Air Exchanges [m3/hr]
Area [m2]
- <=Q01: 1.05E+02 H1: 3.510
- Room 1
- Q10 : 1.05E+02
- LAMBDA: 1.52E+00
- Area 19.710 *
- Deposition velocity: 4.79E-04 [m/s] Resuspension Rate: 6.75E-10 [1/s]
- RESRAD-BUILD Program Output, Version 3.21 11/29/03 13:47:44 Page: 4 **
Title : Yankee Rowe DCGL Sb-125 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Sb-125-DCGL_Build_nov28.bld Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00[m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
SB-125 1.000E+00 3.650E-06 1.390E-05 2.360E-03 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
SB-125 1.000E+00 3.650E-06 1.390E-05 2.360E-03
- RESRAD-BUILD Program Output, Version 3.21 11/29/03 13:47:44 Page: 5 **
Title : Yankee Rowe DCGL Sb-125 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Sb-125-DCGL_Build_nov28.bld Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
SB-125 1.000E+00 3.650E-06 1.390E-05 2.360E-03 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
SB-125 1.000E+00 3.650E-06 1.390E-05 2.360E-03
- RESRAD-BUILD Program Output, Version 3.21 11/29/03 13:47:44 Page: 6 **
Title : Yankee Rowe DCGL Sb-125 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Sb-125-DCGL_Build_nov28.bld Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
SB-125 1.000E+00 3.650E-06 1.390E-05 2.360E-03
- RESRAD-BUILD Program Output, Version 3.21 11/29/03 13:47:44 Page: 7 **
Title : Yankee Rowe DCGL Sb-125 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Sb-125-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years Assessment for Time: 1 Time =0.00E+00 yr Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00 [m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
SB-125 1.000E+00 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
SB-125 1.000E+00
- RESRAD-BUILD Program Output, Version 3.21 11/29/03 13:47:44 Page: 8 **
Title : Yankee Rowe DCGL Sb-125 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Sb-125-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
SB-125 1.000E+00 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
SB-125 1.000E+00 Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
SB-125 1.000E+00
- RESRAD-BUILD Program Output, Version 3.21 11/29/03 13:47:44 Page: 9 **
Title : Yankee Rowe DCGL Sb-125 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Sb-125-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years RESRAD-BUILDDose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Total 1 2 3 4 5 Receptor 1 2.34E-06 7.94E-07 7.94E-07 7.94E-07 7.94E-07 5.51E-06 Total 2.34E-06 7.94E-07 7.94E-07 7.94E-07 7.94E-07 5.51E-06
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:35:03 Page: 2 **
Title : Yankee Rowe DCGL Sr-90 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Sr-90-DCGL_Build_nov28.bld RESRAD-BUILD Input Parameters Number of Sources : 5 Number of Receptors: 1 Total Time : 3.652500E+02 days Fraction Inside : 2.670000E-01 Receptor Information Receptor Room x y z FracTime Inhalation Ingestion(Dust)
[m] [m] [m] [m3/day] [m2/hr]
1 1 2.220 2.220 1.000 1.000 3.36E+01 0.00E+00 Receptor-Source Shielding Relationship Receptor Source Density Thickness Material
[g/cm3] [cm]
1 1 2.40E+00 0.00E+00 Concrete 1 2 2.40E+00 0.00E+00 Concrete 1 3 2.40E+00 0.00E+00 Concrete 1 4 2.40E+00 0.00E+00 Concrete 1 5 2.40E+00 0.00E+00 Concrete
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:35:03 Page: 3 **
Title : Yankee Rowe DCGL Sr-90 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Sr-90-DCGL_Build_nov28.bld Building Information Building Air Exchange Rate: 1.52E+00 1/hr Height[m] Air Exchanges [m3/hr]
Area [m2]
- <=Q01: 1.05E+02 H1: 3.510
- Room 1
- Q10 : 1.05E+02
- LAMBDA: 1.52E+00
- Area 19.710 *
- Deposition velocity: 1.51E-05 [m/s] Resuspension Rate: 1.02E-06 [1/s]
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:35:03 Page: 4 **
Title : Yankee Rowe DCGL Sr-90 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Sr-90-DCGL_Build_nov28.bld Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00[m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
SR-90 1.000E+00 1.530E-04 1.310E-03 2.310E-05 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
SR-90 1.000E+00 1.530E-04 1.310E-03 2.310E-05
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:35:03 Page: 5 **
Title : Yankee Rowe DCGL Sr-90 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Sr-90-DCGL_Build_nov28.bld Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
SR-90 1.000E+00 1.530E-04 1.310E-03 2.310E-05 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
SR-90 1.000E+00 1.530E-04 1.310E-03 2.310E-05
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:35:03 Page: 6 **
Title : Yankee Rowe DCGL Sr-90 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Sr-90-DCGL_Build_nov28.bld Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
SR-90 1.000E+00 1.530E-04 1.310E-03 2.310E-05
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:35:03 Page: 7 **
Title : Yankee Rowe DCGL Sr-90 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Sr-90-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years Assessment for Time: 1 Time =0.00E+00 yr Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00 [m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
SR-90 1.000E+00 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
SR-90 1.000E+00
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:35:03 Page: 8 **
Title : Yankee Rowe DCGL Sr-90 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Sr-90-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
SR-90 1.000E+00 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
SR-90 1.000E+00 Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76 [m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 1.824E+04 [day]
Contamination:: Nuclide Concentration
[pCi/m2]
SR-90 1.000E+00
- RESRAD-BUILD Program Output, Version 3.21 11/28/03 15:35:03 Page: 9 **
Title : Yankee Rowe DCGL Sr-90 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Sr-90-DCGL_Build_nov28.bld Evaluation Time: 0.00000000E+00 years RESRAD-BUILDDose Tables Source Contributions to Receptor Doses
[mrem]
Source Source Source Source Source Total 1 2 3 4 5 Receptor 1 9.71E-07 7.52E-07 7.52E-07 7.52E-07 7.52E-07 3.98E-06 Total 9.71E-07 7.52E-07 7.52E-07 7.52E-07 7.52E-07 3.98E-06
- RESRAD-BUILD Program Output, Version 3.21 12/17/03 08:26:02 Page: 2 **
Title : Yankee Rowe DCGL Tc-99 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Tc-99-DCGL_Build_nov28.bld RESRAD-BUILD Input Parameters Number of Sources : 5 Number of Receptors: 1 Total Time : 3.652500E+02 days Fraction Inside : 2.670000E-01 Receptor Information Receptor Room x y z FracTime Inhalation Ingestion(Dust)
[m] [m] [m] [m3/day] [m2/hr]
1 1 2.220 2.220 1.000 1.000 3.36E+01 0.00E+00 Receptor-Source Shielding Relationship Receptor Source Density Thickness Material
[g/cm3] [cm]
1 1 2.40E+00 0.00E+00 Concrete 1 2 2.40E+00 0.00E+00 Concrete 1 3 2.40E+00 0.00E+00 Concrete 1 4 2.40E+00 0.00E+00 Concrete 1 5 2.40E+00 0.00E+00 Concrete
- RESRAD-BUILD Program Output, Version 3.21 12/17/03 08:26:02 Page: 3 **
Title : Yankee Rowe DCGL Tc-99 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Tc-99-DCGL_Build_nov28.bld Building Information Building Air Exchange Rate: 1.52E+00 1/hr Height[m] Air Exchanges [m3/hr]
Area [m2]
- <=Q01: 1.05E+02 H1: 3.510
- Room 1
- Q10 : 1.05E+02
- LAMBDA: 1.52E+00
- Area 19.710 *
- Deposition velocity: 8.53E-05 [m/s] Resuspension Rate: 1.83E-08 [1/s]
- RESRAD-BUILD Program Output, Version 3.21 12/17/03 08:26:02 Page: 4 **
Title : Yankee Rowe DCGL Tc-99 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Tc-99-DCGL_Build_nov28.bld Source Information Source: 1 Location:: Room : 1 x: 2.22 y: 2.22 z: 0.00[m]
Geometry:: Type: Area Area:1.97E+01 [m2] Direction: z Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
TC-99 1.000E+00 1.460E-06 8.330E-06 1.900E-07 Source: 2 Location:: Room : 1 x: 0.00 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
TC-99 1.000E+00 1.460E-06 8.330E-06 1.900E-07
- RESRAD-BUILD Program Output, Version 3.21 12/17/03 08:26:02 Page: 5 **
Title : Yankee Rowe DCGL Tc-99 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Tc-99-DCGL_Build_nov28.bld Source: 3 Location:: Room : 1 x: 2.22 y: 4.44 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
TC-99 1.000E+00 1.460E-06 8.330E-06 1.900E-07 Source: 4 Location:: Room : 1 x: 4.44 y: 2.22 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: x Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
TC-99 1.000E+00 1.460E-06 8.330E-06 1.900E-07
- RESRAD-BUILD Program Output, Version 3.21 12/17/03 08:26:02 Page: 6 **
Title : Yankee Rowe DCGL Tc-99 Input File : C:\\Program Files\\RESRAD_Family\\BUILD\\Tc-99-DCGL_Build_nov28.bld Source: 5 Location:: Room : 1 x: 2.22 y: 0.00 z: 1.76[m]
Geometry:: Type: Area Area:1.56E+01 [m2] Direction: y Pathway ::
Direct Ingestion Rate: 1.340E-06 [1/hr]
Fraction released to air: 7.000E-02 Removable fraction: 1.000E-01 Time to Remove: 5.278E+04 [day]
Contamination::
Nuclide Concentration Dose Conversion Factor (Library:
Ingestion Inhalation Submersion
[pCi/m2] [mrem/pCi] [mrem/pCi] [mrem/yr/
(pCi/m3)]
TC-99 1.000E+00 1.460E-06 8.330E-06 1.900E-07