1RESRAD, Version 6.21 T<< Limit = 0.5 year 05/21/2003 12:08 Page 2 Summary : Yankee Rowe Sensitivity Analysis=soil File: NI-59.RAD Dose Conversion Factor (and Related) Parameter Summary File: FGR 13 Morbidity 0 ³ ³ Current ³ ³ Parameter Menu ³ Parameter ³ Value ³ Default ³ Name

ÅÅÅÅ B-1 ³ Dose conversion factors for inhalation, mrem/pCi: ³ ³ ³ B-1 ³ Ni-59 ³ 2.700E-06 ³ 2.700E-06 ³ DCF2( 1)

³ ³ ³ ³ D-1 ³ Dose conversion factors for ingestion, mrem/pCi: ³ ³ ³ D-1 ³ Ni-59 ³ 2.100E-07 ³ 2.100E-07 ³ DCF3( 1)

³ ³ ³ ³ D-34 ³ Food transfer factors: ³ ³ ³ D-34 ³ Ni-59, plant/soil concentration ratio, dimensionless ³ 5.000E-02 ³ 5.000E-02 ³ RTF( 1,1)

D-34 ³ Ni-59, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 5.000E-03 ³ 5.000E-03 ³ RTF( 1,2)

D-34 ³ Ni-59, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-02 ³ 2.000E-02 ³ RTF( 1,3)

³ ³ ³ ³ D-5 ³ Bioaccumulation factors, fresh water, L/kg: ³ ³ ³ D-5 ³ Ni-59, fish ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 1,1)

D-5 ³ Ni-59, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 1,2) 1RESRAD, Version 6.21 T<< Limit = 0.5 year 05/21/2003 12:08 Page 3 Summary : Yankee Rowe Sensitivity Analysis=soil File: NI-59.RAD Site-Specific Parameter Summary 0 ³ ³ User ³ ³ Used by RESRAD

³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅ

Å R011 ³ Area of contaminated zone (m**2) ³ 1.302E+04 ³ 1.000E+04 ³ ---

³ AREA R011 ³ Thickness of contaminated zone (m) ³ 1.575E+00 ³ 2.000E+00 ³ ---

³ THICK0 R011 ³ Length parallel to aquifer flow (m) ³ 1.290E+02 ³ 1.000E+02 ³ ---

³ LCZPAQ R011 ³ Basic radiation dose limit (mrem/yr) ³ 2.500E+01 ³ 2.500E+01 ³ ---

³ BRDL R011 ³ Time since placement of material (yr) ³ 0.000E+00 ³ 0.000E+00 ³ ---

³ TI R011 ³ Times for calculations (yr) ³ 1.000E+00 ³ 1.000E+00 ³ ---

³ T( 2)

R011 ³ Times for calculations (yr) ³ 3.000E+00 ³ 3.000E+00 ³ ---

³ T( 3)

R011 ³ Times for calculations (yr) ³ 1.000E+01 ³ 1.000E+01 ³ ---

³ T( 4)

R011 ³ Times for calculations (yr) ³ 3.000E+01 ³ 3.000E+01 ³ ---

³ T( 5)

R011 ³ Times for calculations (yr) ³ 1.000E+02 ³ 1.000E+02 ³ ---

³ T( 6)

R011 ³ Times for calculations (yr) ³ 3.000E+02 ³ 3.000E+02 ³ ---

³ T( 7)

R011 ³ Times for calculations (yr) ³ 1.000E+03 ³ 1.000E+03 ³ ---

³ T( 8)

R011 ³ Times for calculations (yr) ³ not used ³ 0.000E+00 ³ ---

³ T( 9)

R011 ³ Times for calculations (yr) ³ not used ³ 0.000E+00 ³ ---

³ T(10)

³ ³ ³ ³

³ R012 ³ Initial principal radionuclide (pCi/g): Ni-59 ³ 1.000E+00 ³ 0.000E+00 ³ ---

³ S1( 1)

R012 ³ Concentration in groundwater (pCi/L): Ni-59 ³ not used ³ 0.000E+00 ³ ---

³ W1( 1)

³ ³ ³ ³

³ R013 ³ Cover depth (m) ³ 0.000E+00 ³ 0.000E+00 ³ ---

³ COVER0 R013 ³ Density of cover material (g/cm**3) ³ not used ³ 1.500E+00 ³ ---

³ DENSCV R013 ³ Cover depth erosion rate (m/yr) ³ not used ³ 1.000E-03 ³ ---

³ VCV R013 ³ Density of contaminated zone (g/cm**3) ³ 1.860E+00 ³ 1.500E+00 ³ ---

³ DENSCZ R013 ³ Contaminated zone erosion rate (m/yr) ³ 8.500E-04 ³ 1.000E-03 ³ ---

³ VCZ R013 ³ Contaminated zone total porosity ³ 3.500E-01 ³ 4.000E-01 ³ ---

³ TPCZ R013 ³ Contaminated zone field capacity ³ 1.000E-01 ³ 2.000E-01 ³ ---

³ FCCZ R013 ³ Contaminated zone hydraulic conductivity (m/yr) ³ 5.550E+02 ³ 1.000E+01 ³ ---

³ HCCZ R013 ³ Contaminated zone b parameter ³ 4.380E+00 ³ 5.300E+00 ³ ---

³ BCZ R013 ³ Average annual wind speed (m/sec) ³ 2.030E+00 ³ 2.000E+00 ³ ---

³ WIND R013 ³ Humidity in air (g/m**3) ³ not used ³ 8.000E+00 ³ ---

³ HUMID R013 ³ Evapotranspiration coefficient ³ 7.500E-01 ³ 5.000E-01 ³ ---

³ EVAPTR R013 ³ Precipitation (m/yr) ³ 1.200E+00 ³ 1.000E+00 ³ ---

³ PRECIP R013 ³ Irrigation (m/yr) ³ 4.350E-01 ³ 2.000E-01 ³ ---

³ RI R013 ³ Irrigation mode ³ overhead ³ overhead ³ ---

³ IDITCH R013 ³ Runoff coefficient ³ 6.000E-01 ³ 2.000E-01 ³ ---

³ RUNOFF R013 ³ Watershed area for nearby stream or pond (m**2) ³ 7.770E+05 ³ 1.000E+06 ³ ---

³ WAREA R013 ³ Accuracy for water/soil computations ³ 1.000E-03 ³ 1.000E-03 ³ ---

³ EPS

³ ³ ³ ³

³ R014 ³ Density of saturated zone (g/cm**3) ³ 2.120E+00 ³ 1.500E+00 ³ ---

³ DENSAQ R014 ³ Saturated zone total porosity ³ 3.000E-01 ³ 4.000E-01 ³ ---

³ TPSZ R014 ³ Saturated zone effective porosity ³ 2.100E-01 ³ 2.000E-01 ³ ---

³ EPSZ R014 ³ Saturated zone field capacity ³ 9.000E-02 ³ 2.000E-01 ³ ---

³ FCSZ R014 ³ Saturated zone hydraulic conductivity (m/yr) ³ 1.000E-01 ³ 1.000E+02 ³ ---

³ HCSZ R014 ³ Saturated zone hydraulic gradient ³ 1.000E-01 ³ 2.000E-02 ³ ---

³ HGWT R014 ³ Saturated zone b parameter ³ 4.900E+00 ³ 5.300E+00 ³ ---

³ BSZ R014 ³ Water table drop rate (m/yr) ³ 1.000E-03 ³ 1.000E-03 ³ ---

³ VWT R014 ³ Well pump intake depth (m below water table) ³ 1.451E+01 ³ 1.000E+01 ³ ---

³ DWIBWT R014 ³ Model: Nondispersion (ND) or Mass-Balance (MB) ³ ND ³ ND ³ ---

³ MODEL R014 ³ Well pumping rate (m**3/yr) ³ 1.323E+03 ³ 2.500E+02 ³ ---

³ UW

³ ³ ³ ³

³ R015 ³ Number of unsaturated zone strata ³ 1 ³ 1 ³ ---

³ NS 1RESRAD, Version 6.21 T<< Limit = 0.5 year 05/21/2003 12:08 Page 4 Summary : Yankee Rowe Sensitivity Analysis=soil File: NI-59.RAD Site-Specific Parameter Summary (continued) 0 ³ ³ User ³ ³ Used by RESRAD

³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅ

Å R015 ³ Unsat. zone 1, thickness (m) ³ 1.430E+00 ³ 4.000E+00 ³ ---

³ H(1)

R015 ³ Unsat. zone 1, soil density (g/cm**3) ³ 1.860E+00 ³ 1.500E+00 ³ ---

³ DENSUZ(1)

R015 ³ Unsat. zone 1, total porosity ³ 3.500E-01 ³ 4.000E-01 ³ ---

³ TPUZ(1)

R015 ³ Unsat. zone 1, effective porosity ³ 2.500E-01 ³ 2.000E-01 ³ ---

³ EPUZ(1)

R015 ³ Unsat. zone 1, field capacity ³ 1.000E-01 ³ 2.000E-01 ³ ---

³ FCUZ(1)

R015 ³ Unsat. zone 1, soil-specific b parameter ³ 4.380E+00 ³ 5.300E+00 ³ ---

³ BUZ(1)

R015 ³ Unsat. zone 1, hydraulic conductivity (m/yr) ³ 5.550E+02 ³ 1.000E+01 ³ ---

³ HCUZ(1)

³ ³ ³ ³

³ R016 ³ Distribution coefficients for Ni-59 ³ ³ ³

³ R016 ³ Contaminated zone (cm**3/g) ³ 4.240E+02 ³ 1.000E+03 ³ ---

³ DCNUCC( 1)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 4.240E+02 ³ 1.000E+03 ³ ---

³ DCNUCU( 1,1)

R016 ³ Saturated zone (cm**3/g) ³ 4.240E+02 ³ 1.000E+03 ³ ---

³ DCNUCS( 1)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.841E-04

³ ALEACH( 1)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used

³ SOLUBK( 1)

³ ³ ³ ³

³ R017 ³ Inhalation rate (m**3/yr) ³ 8.400E+03 ³ 8.400E+03 ³ ---

³ INHALR R017 ³ Mass loading for inhalation (g/m**3) ³ 2.330E-05 ³ 1.000E-04 ³ ---

³ MLINH R017 ³ Exposure duration ³ 3.000E+01 ³ 3.000E+01 ³ ---

³ ED R017 ³ Shielding factor, inhalation ³ 5.500E-01 ³ 4.000E-01 ³ ---

³ SHF3 R017 ³ Shielding factor, external gamma ³ 2.725E-01 ³ 7.000E-01 ³ ---

³ SHF1 R017 ³ Fraction of time spent indoors ³ 6.571E-01 ³ 5.000E-01 ³ ---

³ FIND R017 ³ Fraction of time spent outdoors (on site) ³ 1.181E-01 ³ 2.500E-01 ³ ---

³ FOTD R017 ³ Shape factor flag, external gamma ³ 1.000E+00 ³ 1.000E+00 ³ >0 shows circular AREA.

³ FS R017 ³ Radii of shape factor array (used if FS = -1): ³ ³ ³

³ R017 ³ Outer annular radius (m), ring 1: ³ not used ³ 5.000E+01 ³ ---

³ RAD_SHAPE( 1)

R017 ³ Outer annular radius (m), ring 2: ³ not used ³ 7.071E+01 ³ ---

³ RAD_SHAPE( 2)

R017 ³ Outer annular radius (m), ring 3: ³ not used ³ 0.000E+00 ³ ---

³ RAD_SHAPE( 3)

R017 ³ Outer annular radius (m), ring 4: ³ not used ³ 0.000E+00 ³ ---

³ RAD_SHAPE( 4)

R017 ³ Outer annular radius (m), ring 5: ³ not used ³ 0.000E+00 ³ ---

³ RAD_SHAPE( 5)

R017 ³ Outer annular radius (m), ring 6: ³ not used ³ 0.000E+00 ³ ---

³ RAD_SHAPE( 6)

R017 ³ Outer annular radius (m), ring 7: ³ not used ³ 0.000E+00 ³ ---

³ RAD_SHAPE( 7)

R017 ³ Outer annular radius (m), ring 8: ³ not used ³ 0.000E+00 ³ ---

³ RAD_SHAPE( 8)

R017 ³ Outer annular radius (m), ring 9: ³ not used ³ 0.000E+00 ³ ---

³ RAD_SHAPE( 9)

R017 ³ Outer annular radius (m), ring 10: ³ not used ³ 0.000E+00 ³ ---

³ RAD_SHAPE(10)

R017 ³ Outer annular radius (m), ring 11: ³ not used ³ 0.000E+00 ³ ---

³ RAD_SHAPE(11)

R017 ³ Outer annular radius (m), ring 12: ³ not used ³ 0.000E+00 ³ ---

³ RAD_SHAPE(12)

³ ³ ³ ³

³ R017 ³ Fractions of annular areas within AREA: ³ ³ ³

³ R017 ³ Ring 1 ³ not used ³ 1.000E+00 ³ ---

³ FRACA( 1)

R017 ³ Ring 2 ³ not used ³ 2.732E-01 ³ ---

³ FRACA( 2)

R017 ³ Ring 3 ³ not used ³ 0.000E+00 ³ ---

³ FRACA( 3)

R017 ³ Ring 4 ³ not used ³ 0.000E+00 ³ ---

³ FRACA( 4)

R017 ³ Ring 5 ³ not used ³ 0.000E+00 ³ ---

³ FRACA( 5)

R017 ³ Ring 6 ³ not used ³ 0.000E+00 ³ ---

³ FRACA( 6)

R017 ³ Ring 7 ³ not used ³ 0.000E+00 ³ ---

³ FRACA( 7)

R017 ³ Ring 8 ³ not used ³ 0.000E+00 ³ ---

³ FRACA( 8)

R017 ³ Ring 9 ³ not used ³ 0.000E+00 ³ ---

³ FRACA( 9)

R017 ³ Ring 10 ³ not used ³ 0.000E+00 ³ ---

³ FRACA(10)

R017 ³ Ring 11 ³ not used ³ 0.000E+00 ³ ---

³ FRACA(11)

R017 ³ Ring 12 ³ not used ³ 0.000E+00 ³ ---

³ FRACA(12)

³ ³ ³ ³

³ 1RESRAD, Version 6.21 T<< Limit = 0.5 year 05/21/2003 12:08 Page 5 Summary : Yankee Rowe Sensitivity Analysis=soil File: NI-59.RAD

Site-Specific Parameter Summary (continued) 0 ³ ³ User ³ ³ Used by RESRAD

³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅ

Å R018 ³ Fruits, vegetables and grain consumption (kg/yr) ³ 1.120E+02 ³ 1.600E+02 ³ ---

³ DIET(1)

R018 ³ Leafy vegetable consumption (kg/yr) ³ 2.140E+01 ³ 1.400E+01 ³ ---

³ DIET(2)

R018 ³ Milk consumption (L/yr) ³ 2.330E+02 ³ 9.200E+01 ³ ---

³ DIET(3)

R018 ³ Meat and poultry consumption (kg/yr) ³ 6.510E+01 ³ 6.300E+01 ³ ---

³ DIET(4)

R018 ³ Fish consumption (kg/yr) ³ 2.060E+01 ³ 5.400E+00 ³ ---

³ DIET(5)

R018 ³ Other seafood consumption (kg/yr) ³ 9.000E-01 ³ 9.000E-01 ³ ---

³ DIET(6)

R018 ³ Soil ingestion rate (g/yr) ³ 1.826E+01 ³ 3.650E+01 ³ ---

³ SOIL R018 ³ Drinking water intake (L/yr) ³ 4.785E+02 ³ 5.100E+02 ³ ---

³ DWI R018 ³ Contamination fraction of drinking water ³ 1.000E+00 ³ 1.000E+00 ³ ---

³ FDW R018 ³ Contamination fraction of household water ³ not used ³ 1.000E+00 ³ ---

³ FHHW R018 ³ Contamination fraction of livestock water ³ 1.000E+00 ³ 1.000E+00 ³ ---

³ FLW R018 ³ Contamination fraction of irrigation water ³ 1.000E+00 ³ 1.000E+00 ³ ---

³ FIRW R018 ³ Contamination fraction of aquatic food ³ 1.000E+00 ³ 5.000E-01 ³ ---

³ FR9 R018 ³ Contamination fraction of plant food ³ 1.000E+00 ³-1 ³ ---

³ FPLANT R018 ³ Contamination fraction of meat ³ 1.000E+00 ³-1 ³ ---

³ FMEAT R018 ³ Contamination fraction of milk ³ 1.000E+00 ³-1 ³ ---

³ FMILK

³ ³ ³ ³

³ R019 ³ Livestock fodder intake for meat (kg/day) ³ 2.710E+01 ³ 6.800E+01 ³ ---

³ LFI5 R019 ³ Livestock fodder intake for milk (kg/day) ³ 6.320E+01 ³ 5.500E+01 ³ ---

³ LFI6 R019 ³ Livestock water intake for meat (L/day) ³ 5.060E+01 ³ 5.000E+01 ³ ---

³ LWI5 R019 ³ Livestock water intake for milk (L/day) ³ 6.000E+01 ³ 1.600E+02 ³ ---

³ LWI6 R019 ³ Livestock soil intake (kg/day) ³ 5.000E-01 ³ 5.000E-01 ³ ---

³ LSI R019 ³ Mass loading for foliar deposition (g/m**3) ³ 4.000E-04 ³ 1.000E-04 ³ ---

³ MLFD R019 ³ Depth of soil mixing layer (m) ³ 2.300E-01 ³ 1.500E-01 ³ ---

³ DM R019 ³ Depth of roots (m) ³ 2.150E+00 ³ 9.000E-01 ³ ---

³ DROOT R019 ³ Drinking water fraction from ground water ³ 1.000E+00 ³ 1.000E+00 ³ ---

³ FGWDW R019 ³ Household water fraction from ground water ³ not used ³ 1.000E+00 ³ ---

³ FGWHH R019 ³ Livestock water fraction from ground water ³ 1.000E+00 ³ 1.000E+00 ³ ---

³ FGWLW R019 ³ Irrigation fraction from ground water ³ 1.000E+00 ³ 1.000E+00 ³ ---

³ FGWIR

³ ³ ³ ³

³ R19B ³ Wet weight crop yield for Non-Leafy (kg/m**2) ³ 1.750E+00 ³ 7.000E-01 ³ ---

³ YV(1)

R19B ³ Wet weight crop yield for Leafy (kg/m**2) ³ 2.889E+00 ³ 1.500E+00 ³ ---

³ YV(2)

R19B ³ Wet weight crop yield for Fodder (kg/m**2) ³ 1.887E+00 ³ 1.100E+00 ³ ---

³ YV(3)

R19B ³ Growing Season for Non-Leafy (years) ³ 2.460E-01 ³ 1.700E-01 ³ ---

³ TE(1)

R19B ³ Growing Season for Leafy (years) ³ 1.230E-01 ³ 2.500E-01 ³ ---

³ TE(2)

R19B ³ Growing Season for Fodder (years) ³ 8.200E-02 ³ 8.000E-02 ³ ---

³ TE(3)

R19B ³ Translocation Factor for Non-Leafy ³ 1.000E-01 ³ 1.000E-01 ³ ---

³ TIV(1)

R19B ³ Translocation Factor for Leafy ³ 1.000E+00 ³ 1.000E+00 ³ ---

³ TIV(2)

R19B ³ Translocation Factor for Fodder ³ 1.000E+00 ³ 1.000E+00 ³ ---

³ TIV(3)

R19B ³ Dry Foliar Interception Fraction for Non-Leafy ³ 3.500E-01 ³ 2.500E-01 ³ ---

³ RDRY(1)

R19B ³ Dry Foliar Interception Fraction for Leafy ³ 3.500E-01 ³ 2.500E-01 ³ ---

³ RDRY(2)

R19B ³ Dry Foliar Interception Fraction for Fodder ³ 3.500E-01 ³ 2.500E-01 ³ ---

³ RDRY(3)

R19B ³ Wet Foliar Interception Fraction for Non-Leafy ³ 3.500E-01 ³ 2.500E-01 ³ ---

³ RWET(1)

R19B ³ Wet Foliar Interception Fraction for Leafy ³ 5.800E-01 ³ 2.500E-01 ³ ---

³ RWET(2)

R19B ³ Wet Foliar Interception Fraction for Fodder ³ 3.500E-01 ³ 2.500E-01 ³ ---

³ RWET(3)

R19B ³ Weathering Removal Constant for Vegetation ³ 3.300E+01 ³ 2.000E+01 ³ ---

³ WLAM

³ ³ ³ ³

³ C14 ³ C-12 concentration in water (g/cm**3) ³ not used ³ 2.000E-05 ³ ---

³ C12WTR C14 ³ C-12 concentration in contaminated soil (g/g) ³ not used ³ 3.000E-02 ³ ---

³ C12CZ C14 ³ Fraction of vegetation carbon from soil ³ not used ³ 2.000E-02 ³ ---

³ CSOIL C14 ³ Fraction of vegetation carbon from air ³ not used ³ 9.800E-01 ³ ---

³ CAIR 1RESRAD, Version 6.21 T<< Limit = 0.5 year 05/21/2003 12:08 Page 6 Summary : Yankee Rowe Sensitivity Analysis=soil File: NI-59.RAD Site-Specific Parameter Summary (continued) 0 ³ ³ User ³ ³ Used by RESRAD

³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅ

Å C14 ³ C-14 evasion layer thickness in soil (m) ³ not used ³ 3.000E-01 ³ ---

³ DMC C14 ³ C-14 evasion flux rate from soil (1/sec) ³ not used ³ 7.000E-07 ³ ---

³ EVSN C14 ³ C-12 evasion flux rate from soil (1/sec) ³ not used ³ 1.000E-10 ³ ---

³ REVSN C14 ³ Fraction of grain in beef cattle feed ³ not used ³ 8.000E-01 ³ ---

³ AVFG4 C14 ³ Fraction of grain in milk cow feed ³ not used ³ 2.000E-01 ³ ---

³ AVFG5 C14 ³ DCF correction factor for gaseous forms of C14 ³ not used ³ 8.894E+01 ³ ---

³ CO2F

³ ³ ³ ³

³ STOR ³ Storage times of contaminated foodstuffs (days): ³ ³ ³

³ STOR ³ Fruits, non-leafy vegetables, and grain ³ 1.400E+01 ³ 1.400E+01 ³ ---

³ STOR_T(1)

STOR ³ Leafy vegetables ³ 1.000E+00 ³ 1.000E+00 ³ ---

³ STOR_T(2)

STOR ³ Milk ³ 1.000E+00 ³ 1.000E+00 ³ ---

³ STOR_T(3)

STOR ³ Meat and poultry ³ 2.000E+01 ³ 2.000E+01 ³ ---

³ STOR_T(4)

STOR ³ Fish ³ 7.000E+00 ³ 7.000E+00 ³ ---

³ STOR_T(5)

STOR ³ Crustacea and mollusks ³ 7.000E+00 ³ 7.000E+00 ³ ---

³ STOR_T(6)

STOR ³ Well water ³ 1.000E+00 ³ 1.000E+00 ³ ---

³ STOR_T(7)

STOR ³ Surface water ³ 1.000E+00 ³ 1.000E+00 ³ ---

³ STOR_T(8)

STOR ³ Livestock fodder ³ 4.500E+01 ³ 4.500E+01 ³ ---

³ STOR_T(9)

³ ³ ³ ³

³ R021 ³ Thickness of building foundation (m) ³ not used ³ 1.500E-01 ³ ---

³ FLOOR1 R021 ³ Bulk density of building foundation (g/cm**3) ³ not used ³ 2.400E+00 ³ ---

³ DENSFL R021 ³ Total porosity of the cover material ³ not used ³ 4.000E-01 ³ ---

³ TPCV R021 ³ Total porosity of the building foundation ³ not used ³ 1.000E-01 ³ ---

³ TPFL

R021 ³ Volumetric water content of the cover material ³ not used ³ 5.000E-02 ³ ---

³ PH2OCV R021 ³ Volumetric water content of the foundation ³ not used ³ 3.000E-02 ³ ---

³ PH2OFL R021 ³ Diffusion coefficient for radon gas (m/sec): ³ ³ ³

³ R021 ³ in cover material ³ not used ³ 2.000E-06 ³ ---

³ DIFCV R021 ³ in foundation material ³ not used ³ 3.000E-07 ³ ---

³ DIFFL R021 ³ in contaminated zone soil ³ not used ³ 2.000E-06 ³ ---

³ DIFCZ R021 ³ Radon vertical dimension of mixing (m) ³ not used ³ 2.000E+00 ³ ---

³ HMIX R021 ³ Average building air exchange rate (1/hr) ³ not used ³ 5.000E-01 ³ ---

³ REXG R021 ³ Height of the building (room) (m) ³ not used ³ 2.500E+00 ³ ---

³ HRM R021 ³ Building interior area factor ³ not used ³ 0.000E+00 ³ ---

³ FAI R021 ³ Building depth below ground surface (m) ³ not used ³-1.000E+00 ³ ---

³ DMFL R021 ³ Emanating power of Rn-222 gas ³ not used ³ 2.500E-01 ³ ---

³ EMANA(1)

R021 ³ Emanating power of Rn-220 gas ³ not used ³ 1.500E-01 ³ ---

³ EMANA(2)

³ ³ ³ ³

³ TITL ³ Number of graphical time points ³ 32 ³ --- ³ ---

³ NPTS TITL ³ Maximum number of integration points for dose ³ 17 ³ --- ³ ---

³ LYMAX TITL ³ Maximum number of integration points for risk ³ 1 ³ --- ³ ---

³ KYMAX

1RESRAD, Version 6.21 T<< Limit = 0.5 year 05/21/2003 12:08 Page 7 Summary : Yankee Rowe Sensitivity Analysis=soil File: NI-59.RAD Summary of Pathway Selections Pathway ³ User Selection

Å 1 -- external gamma ³ active 2 -- inhalation (w/o radon)³ active 3 -- plant ingestion ³ active 4 -- meat ingestion ³ active 5 -- milk ingestion ³ active 6 -- aquatic foods ³ active 7 -- drinking water ³ active 8 -- soil ingestion ³ active 9 -- radon ³ suppressed Find peak pathway doses ³ active

1RESRAD, Version 6.21 T<< Limit = 0.5 year 04/29/2003 18:18 Page 2 Summary : Yankee Rowe Sensitivity Analysis=soil File: YR_Ni-63.RAD Dose Conversion Factor (and Related) Parameter Summary File: FGR 13 Morbidity 0 ³ ³ Current ³ ³ Parameter Menu ³ Parameter ³ Value ³ Default ³ Name

ÅÅÅÅ B-1 ³ Dose conversion factors for inhalation, mrem/pCi: ³ ³ ³ B-1 ³ Ni-63 ³ 6.290E-06 ³ 6.290E-06 ³ DCF2( 1)

³ ³ ³ ³ D-1 ³ Dose conversion factors for ingestion, mrem/pCi: ³ ³ ³ D-1 ³ Ni-63 ³ 5.770E-07 ³ 5.770E-07 ³ DCF3( 1)

³ ³ ³ ³ D-34 ³ Food transfer factors: ³ ³ ³ D-34 ³ Ni-63, plant/soil concentration ratio, dimensionless ³ 5.000E-02 ³ 5.000E-02 ³ RTF( 1,1)

D-34 ³ Ni-63, beef/livestock-intake ratio, (pCi/kg)/(pCi/d) ³ 5.000E-03 ³ 5.000E-03 ³ RTF( 1,2)

D-34 ³ Ni-63, milk/livestock-intake ratio, (pCi/L)/(pCi/d) ³ 2.000E-02 ³ 2.000E-02 ³ RTF( 1,3)

³ ³ ³ ³ D-5 ³ Bioaccumulation factors, fresh water, L/kg: ³ ³ ³ D-5 ³ Ni-63, fish ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 1,1)

D-5 ³ Ni-63, crustacea and mollusks ³ 1.000E+02 ³ 1.000E+02 ³ BIOFAC( 1,2) 1RESRAD, Version 6.21 T<< Limit = 0.5 year 04/29/2003 18:18 Page 3 Summary : Yankee Rowe Sensitivity Analysis=soil File: YR_Ni-63.RAD Site-Specific Parameter Summary 0 ³ ³ User ³ ³ Used by RESRAD

³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅ

Å R011 ³ Area of contaminated zone (m**2) ³ 1.302E+04 ³ 1.000E+04 ³ ---

³ AREA R011 ³ Thickness of contaminated zone (m) ³ 1.575E+00 ³ 2.000E+00 ³ ---

³ THICK0 R011 ³ Length parallel to aquifer flow (m) ³ 1.290E+02 ³ 1.000E+02 ³ ---

³ LCZPAQ R011 ³ Basic radiation dose limit (mrem/yr) ³ 2.500E+01 ³ 2.500E+01 ³ ---

³ BRDL R011 ³ Time since placement of material (yr) ³ 0.000E+00 ³ 0.000E+00 ³ ---

³ TI R011 ³ Times for calculations (yr) ³ 1.000E+00 ³ 1.000E+00 ³ ---

³ T( 2)

R011 ³ Times for calculations (yr) ³ 3.000E+00 ³ 3.000E+00 ³ ---

³ T( 3)

R011 ³ Times for calculations (yr) ³ 1.000E+01 ³ 1.000E+01 ³ ---

³ T( 4)

R011 ³ Times for calculations (yr) ³ 3.000E+01 ³ 3.000E+01 ³ ---

³ T( 5)

R011 ³ Times for calculations (yr) ³ 1.000E+02 ³ 1.000E+02 ³ ---

³ T( 6)

R011 ³ Times for calculations (yr) ³ 3.000E+02 ³ 3.000E+02 ³ ---

³ T( 7)

R011 ³ Times for calculations (yr) ³ 1.000E+03 ³ 1.000E+03 ³ ---

³ T( 8)

R011 ³ Times for calculations (yr) ³ not used ³ 0.000E+00 ³ ---

³ T( 9)

R011 ³ Times for calculations (yr) ³ not used ³ 0.000E+00 ³ ---

³ T(10)

³ ³ ³ ³

³ R012 ³ Initial principal radionuclide (pCi/g): Ni-63 ³ 1.000E+00 ³ 0.000E+00 ³ ---

³ S1( 1)

R012 ³ Concentration in groundwater (pCi/L): Ni-63 ³ not used ³ 0.000E+00 ³ ---

³ W1( 1)

³ ³ ³ ³

³ R013 ³ Cover depth (m) ³ 0.000E+00 ³ 0.000E+00 ³ ---

³ COVER0 R013 ³ Density of cover material (g/cm**3) ³ not used ³ 1.500E+00 ³ ---

³ DENSCV R013 ³ Cover depth erosion rate (m/yr) ³ not used ³ 1.000E-03 ³ ---

³ VCV R013 ³ Density of contaminated zone (g/cm**3) ³ 1.860E+00 ³ 1.500E+00 ³ ---

³ DENSCZ R013 ³ Contaminated zone erosion rate (m/yr) ³ 8.500E-04 ³ 1.000E-03 ³ ---

³ VCZ R013 ³ Contaminated zone total porosity ³ 3.500E-01 ³ 4.000E-01 ³ ---

³ TPCZ R013 ³ Contaminated zone field capacity ³ 1.000E-01 ³ 2.000E-01 ³ ---

³ FCCZ R013 ³ Contaminated zone hydraulic conductivity (m/yr) ³ 5.550E+02 ³ 1.000E+01 ³ ---

³ HCCZ R013 ³ Contaminated zone b parameter ³ 4.380E+00 ³ 5.300E+00 ³ ---

³ BCZ R013 ³ Average annual wind speed (m/sec) ³ 2.030E+00 ³ 2.000E+00 ³ ---

³ WIND R013 ³ Humidity in air (g/m**3) ³ not used ³ 8.000E+00 ³ ---

³ HUMID R013 ³ Evapotranspiration coefficient ³ 7.500E-01 ³ 5.000E-01 ³ ---

³ EVAPTR R013 ³ Precipitation (m/yr) ³ 1.200E+00 ³ 1.000E+00 ³ ---

³ PRECIP R013 ³ Irrigation (m/yr) ³ 4.350E-01 ³ 2.000E-01 ³ ---

³ RI R013 ³ Irrigation mode ³ overhead ³ overhead ³ ---

³ IDITCH R013 ³ Runoff coefficient ³ 6.000E-01 ³ 2.000E-01 ³ ---

³ RUNOFF R013 ³ Watershed area for nearby stream or pond (m**2) ³ 7.770E+05 ³ 1.000E+06 ³ ---

³ WAREA R013 ³ Accuracy for water/soil computations ³ 1.000E-03 ³ 1.000E-03 ³ ---

³ EPS

³ ³ ³ ³

³ R014 ³ Density of saturated zone (g/cm**3) ³ 2.120E+00 ³ 1.500E+00 ³ ---

³ DENSAQ R014 ³ Saturated zone total porosity ³ 3.000E-01 ³ 4.000E-01 ³ ---

³ TPSZ R014 ³ Saturated zone effective porosity ³ 2.100E-01 ³ 2.000E-01 ³ ---

³ EPSZ R014 ³ Saturated zone field capacity ³ 9.000E-02 ³ 2.000E-01 ³ ---

³ FCSZ R014 ³ Saturated zone hydraulic conductivity (m/yr) ³ 1.000E-01 ³ 1.000E+02 ³ ---

³ HCSZ R014 ³ Saturated zone hydraulic gradient ³ 1.000E-01 ³ 2.000E-02 ³ ---

³ HGWT R014 ³ Saturated zone b parameter ³ 4.900E+00 ³ 5.300E+00 ³ ---

³ BSZ R014 ³ Water table drop rate (m/yr) ³ 1.000E-03 ³ 1.000E-03 ³ ---

³ VWT R014 ³ Well pump intake depth (m below water table) ³ 1.451E+01 ³ 1.000E+01 ³ ---

³ DWIBWT R014 ³ Model: Nondispersion (ND) or Mass-Balance (MB) ³ ND ³ ND ³ ---

³ MODEL R014 ³ Well pumping rate (m**3/yr) ³ 1.323E+03 ³ 2.500E+02 ³ ---

³ UW

³ ³ ³ ³

³ R015 ³ Number of unsaturated zone strata ³ 1 ³ 1 ³ ---

³ NS 1RESRAD, Version 6.21 T<< Limit = 0.5 year 04/29/2003 18:18 Page 4 Summary : Yankee Rowe Sensitivity Analysis=soil File: YR_Ni-63.RAD Site-Specific Parameter Summary (continued) 0 ³ ³ User ³ ³ Used by RESRAD

³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅ

Å R015 ³ Unsat. zone 1, thickness (m) ³ 1.430E+00 ³ 4.000E+00 ³ ---

³ H(1)

R015 ³ Unsat. zone 1, soil density (g/cm**3) ³ 1.860E+00 ³ 1.500E+00 ³ ---

³ DENSUZ(1)

R015 ³ Unsat. zone 1, total porosity ³ 3.500E-01 ³ 4.000E-01 ³ ---

³ TPUZ(1)

R015 ³ Unsat. zone 1, effective porosity ³ 2.500E-01 ³ 2.000E-01 ³ ---

³ EPUZ(1)

R015 ³ Unsat. zone 1, field capacity ³ 1.000E-01 ³ 2.000E-01 ³ ---

³ FCUZ(1)

R015 ³ Unsat. zone 1, soil-specific b parameter ³ 4.380E+00 ³ 5.300E+00 ³ ---

³ BUZ(1)

R015 ³ Unsat. zone 1, hydraulic conductivity (m/yr) ³ 5.550E+02 ³ 1.000E+01 ³ ---

³ HCUZ(1)

³ ³ ³ ³

³ R016 ³ Distribution coefficients for Ni-63 ³ ³ ³

³ R016 ³ Contaminated zone (cm**3/g) ³ 4.240E+02 ³ 1.000E+03 ³ ---

³ DCNUCC( 1)

R016 ³ Unsaturated zone 1 (cm**3/g) ³ 4.240E+02 ³ 1.000E+03 ³ ---

³ DCNUCU( 1,1)

R016 ³ Saturated zone (cm**3/g) ³ 4.240E+02 ³ 1.000E+03 ³ ---

³ DCNUCS( 1)

R016 ³ Leach rate (/yr) ³ 0.000E+00 ³ 0.000E+00 ³ 1.841E-04

³ ALEACH( 1)

R016 ³ Solubility constant ³ 0.000E+00 ³ 0.000E+00 ³ not used

³ SOLUBK( 1)

³ ³ ³ ³

³ R017 ³ Inhalation rate (m**3/yr) ³ 8.400E+03 ³ 8.400E+03 ³ ---

³ INHALR R017 ³ Mass loading for inhalation (g/m**3) ³ 2.330E-05 ³ 1.000E-04 ³ ---

³ MLINH R017 ³ Exposure duration ³ 3.000E+01 ³ 3.000E+01 ³ ---

³ ED R017 ³ Shielding factor, inhalation ³ 5.500E-01 ³ 4.000E-01 ³ ---

³ SHF3 R017 ³ Shielding factor, external gamma ³ 2.725E-01 ³ 7.000E-01 ³ ---

³ SHF1 R017 ³ Fraction of time spent indoors ³ 6.571E-01 ³ 5.000E-01 ³ ---

³ FIND R017 ³ Fraction of time spent outdoors (on site) ³ 1.181E-01 ³ 2.500E-01 ³ ---

³ FOTD R017 ³ Shape factor flag, external gamma ³ 1.000E+00 ³ 1.000E+00 ³ >0 shows circular AREA.

³ FS R017 ³ Radii of shape factor array (used if FS = -1): ³ ³ ³

³ R017 ³ Outer annular radius (m), ring 1: ³ not used ³ 5.000E+01 ³ ---

³ RAD_SHAPE( 1)

R017 ³ Outer annular radius (m), ring 2: ³ not used ³ 7.071E+01 ³ ---

³ RAD_SHAPE( 2)

R017 ³ Outer annular radius (m), ring 3: ³ not used ³ 0.000E+00 ³ ---

³ RAD_SHAPE( 3)

R017 ³ Outer annular radius (m), ring 4: ³ not used ³ 0.000E+00 ³ ---

³ RAD_SHAPE( 4)

R017 ³ Outer annular radius (m), ring 5: ³ not used ³ 0.000E+00 ³ ---

³ RAD_SHAPE( 5)

R017 ³ Outer annular radius (m), ring 6: ³ not used ³ 0.000E+00 ³ ---

³ RAD_SHAPE( 6)

R017 ³ Outer annular radius (m), ring 7: ³ not used ³ 0.000E+00 ³ ---

³ RAD_SHAPE( 7)

R017 ³ Outer annular radius (m), ring 8: ³ not used ³ 0.000E+00 ³ ---

³ RAD_SHAPE( 8)

R017 ³ Outer annular radius (m), ring 9: ³ not used ³ 0.000E+00 ³ ---

³ RAD_SHAPE( 9)

R017 ³ Outer annular radius (m), ring 10: ³ not used ³ 0.000E+00 ³ ---

³ RAD_SHAPE(10)

R017 ³ Outer annular radius (m), ring 11: ³ not used ³ 0.000E+00 ³ ---

³ RAD_SHAPE(11)

R017 ³ Outer annular radius (m), ring 12: ³ not used ³ 0.000E+00 ³ ---

³ RAD_SHAPE(12)

³ ³ ³ ³

³ R017 ³ Fractions of annular areas within AREA: ³ ³ ³

³ R017 ³ Ring 1 ³ not used ³ 1.000E+00 ³ ---

³ FRACA( 1)

R017 ³ Ring 2 ³ not used ³ 2.732E-01 ³ ---

³ FRACA( 2)

R017 ³ Ring 3 ³ not used ³ 0.000E+00 ³ ---

³ FRACA( 3)

R017 ³ Ring 4 ³ not used ³ 0.000E+00 ³ ---

³ FRACA( 4)

R017 ³ Ring 5 ³ not used ³ 0.000E+00 ³ ---

³ FRACA( 5)

R017 ³ Ring 6 ³ not used ³ 0.000E+00 ³ ---

³ FRACA( 6)

R017 ³ Ring 7 ³ not used ³ 0.000E+00 ³ ---

³ FRACA( 7)

R017 ³ Ring 8 ³ not used ³ 0.000E+00 ³ ---

³ FRACA( 8)

R017 ³ Ring 9 ³ not used ³ 0.000E+00 ³ ---

³ FRACA( 9)

R017 ³ Ring 10 ³ not used ³ 0.000E+00 ³ ---

³ FRACA(10)

R017 ³ Ring 11 ³ not used ³ 0.000E+00 ³ ---

³ FRACA(11)

R017 ³ Ring 12 ³ not used ³ 0.000E+00 ³ ---

³ FRACA(12)

³ ³ ³ ³

³ 1RESRAD, Version 6.21 T<< Limit = 0.5 year 04/29/2003 18:18 Page 5 Summary : Yankee Rowe Sensitivity Analysis=soil File: YR_Ni-63.RAD

Site-Specific Parameter Summary (continued) 0 ³ ³ User ³ ³ Used by RESRAD

³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅ

Å R018 ³ Fruits, vegetables and grain consumption (kg/yr) ³ 1.120E+02 ³ 1.600E+02 ³ ---

³ DIET(1)

R018 ³ Leafy vegetable consumption (kg/yr) ³ 2.140E+01 ³ 1.400E+01 ³ ---

³ DIET(2)

R018 ³ Milk consumption (L/yr) ³ 2.330E+02 ³ 9.200E+01 ³ ---

³ DIET(3)

R018 ³ Meat and poultry consumption (kg/yr) ³ 6.510E+01 ³ 6.300E+01 ³ ---

³ DIET(4)

R018 ³ Fish consumption (kg/yr) ³ 2.060E+01 ³ 5.400E+00 ³ ---

³ DIET(5)

R018 ³ Other seafood consumption (kg/yr) ³ 9.000E-01 ³ 9.000E-01 ³ ---

³ DIET(6)

R018 ³ Soil ingestion rate (g/yr) ³ 1.826E+01 ³ 3.650E+01 ³ ---

³ SOIL R018 ³ Drinking water intake (L/yr) ³ 4.785E+02 ³ 5.100E+02 ³ ---

³ DWI R018 ³ Contamination fraction of drinking water ³ 1.000E+00 ³ 1.000E+00 ³ ---

³ FDW R018 ³ Contamination fraction of household water ³ not used ³ 1.000E+00 ³ ---

³ FHHW R018 ³ Contamination fraction of livestock water ³ 1.000E+00 ³ 1.000E+00 ³ ---

³ FLW R018 ³ Contamination fraction of irrigation water ³ 1.000E+00 ³ 1.000E+00 ³ ---

³ FIRW R018 ³ Contamination fraction of aquatic food ³ 1.000E+00 ³ 5.000E-01 ³ ---

³ FR9 R018 ³ Contamination fraction of plant food ³ 1.000E+00 ³-1 ³ ---

³ FPLANT R018 ³ Contamination fraction of meat ³ 1.000E+00 ³-1 ³ ---

³ FMEAT R018 ³ Contamination fraction of milk ³ 1.000E+00 ³-1 ³ ---

³ FMILK

³ ³ ³ ³

³ R019 ³ Livestock fodder intake for meat (kg/day) ³ 2.710E+01 ³ 6.800E+01 ³ ---

³ LFI5 R019 ³ Livestock fodder intake for milk (kg/day) ³ 6.320E+01 ³ 5.500E+01 ³ ---

³ LFI6 R019 ³ Livestock water intake for meat (L/day) ³ 5.060E+01 ³ 5.000E+01 ³ ---

³ LWI5 R019 ³ Livestock water intake for milk (L/day) ³ 6.000E+01 ³ 1.600E+02 ³ ---

³ LWI6 R019 ³ Livestock soil intake (kg/day) ³ 5.000E-01 ³ 5.000E-01 ³ ---

³ LSI R019 ³ Mass loading for foliar deposition (g/m**3) ³ 4.000E-04 ³ 1.000E-04 ³ ---

³ MLFD R019 ³ Depth of soil mixing layer (m) ³ 2.300E-01 ³ 1.500E-01 ³ ---

³ DM R019 ³ Depth of roots (m) ³ 2.150E+00 ³ 9.000E-01 ³ ---

³ DROOT R019 ³ Drinking water fraction from ground water ³ 1.000E+00 ³ 1.000E+00 ³ ---

³ FGWDW R019 ³ Household water fraction from ground water ³ not used ³ 1.000E+00 ³ ---

³ FGWHH R019 ³ Livestock water fraction from ground water ³ 1.000E+00 ³ 1.000E+00 ³ ---

³ FGWLW R019 ³ Irrigation fraction from ground water ³ 1.000E+00 ³ 1.000E+00 ³ ---

³ FGWIR

³ ³ ³ ³

³ R19B ³ Wet weight crop yield for Non-Leafy (kg/m**2) ³ 1.750E+00 ³ 7.000E-01 ³ ---

³ YV(1)

R19B ³ Wet weight crop yield for Leafy (kg/m**2) ³ 2.889E+00 ³ 1.500E+00 ³ ---

³ YV(2)

R19B ³ Wet weight crop yield for Fodder (kg/m**2) ³ 1.887E+00 ³ 1.100E+00 ³ ---

³ YV(3)

R19B ³ Growing Season for Non-Leafy (years) ³ 2.460E-01 ³ 1.700E-01 ³ ---

³ TE(1)

R19B ³ Growing Season for Leafy (years) ³ 1.230E-01 ³ 2.500E-01 ³ ---

³ TE(2)

R19B ³ Growing Season for Fodder (years) ³ 8.200E-02 ³ 8.000E-02 ³ ---

³ TE(3)

R19B ³ Translocation Factor for Non-Leafy ³ 1.000E-01 ³ 1.000E-01 ³ ---

³ TIV(1)

R19B ³ Translocation Factor for Leafy ³ 1.000E+00 ³ 1.000E+00 ³ ---

³ TIV(2)

R19B ³ Translocation Factor for Fodder ³ 1.000E+00 ³ 1.000E+00 ³ ---

³ TIV(3)

R19B ³ Dry Foliar Interception Fraction for Non-Leafy ³ 3.500E-01 ³ 2.500E-01 ³ ---

³ RDRY(1)

R19B ³ Dry Foliar Interception Fraction for Leafy ³ 3.500E-01 ³ 2.500E-01 ³ ---

³ RDRY(2)

R19B ³ Dry Foliar Interception Fraction for Fodder ³ 3.500E-01 ³ 2.500E-01 ³ ---

³ RDRY(3)

R19B ³ Wet Foliar Interception Fraction for Non-Leafy ³ 3.500E-01 ³ 2.500E-01 ³ ---

³ RWET(1)

R19B ³ Wet Foliar Interception Fraction for Leafy ³ 5.800E-01 ³ 2.500E-01 ³ ---

³ RWET(2)

R19B ³ Wet Foliar Interception Fraction for Fodder ³ 3.500E-01 ³ 2.500E-01 ³ ---

³ RWET(3)

R19B ³ Weathering Removal Constant for Vegetation ³ 3.300E+01 ³ 2.000E+01 ³ ---

³ WLAM

³ ³ ³ ³

³ C14 ³ C-12 concentration in water (g/cm**3) ³ not used ³ 2.000E-05 ³ ---

³ C12WTR C14 ³ C-12 concentration in contaminated soil (g/g) ³ not used ³ 3.000E-02 ³ ---

³ C12CZ C14 ³ Fraction of vegetation carbon from soil ³ not used ³ 2.000E-02 ³ ---

³ CSOIL C14 ³ Fraction of vegetation carbon from air ³ not used ³ 9.800E-01 ³ ---

³ CAIR 1RESRAD, Version 6.21 T<< Limit = 0.5 year 04/29/2003 18:18 Page 6 Summary : Yankee Rowe Sensitivity Analysis=soil File: YR_Ni-63.RAD Site-Specific Parameter Summary (continued) 0 ³ ³ User ³ ³ Used by RESRAD

³ Parameter Menu ³ Parameter ³ Input ³ Default ³ (If different from user input) ³ Name

ÅÅÅÅ

Å C14 ³ C-14 evasion layer thickness in soil (m) ³ not used ³ 3.000E-01 ³ ---

³ DMC C14 ³ C-14 evasion flux rate from soil (1/sec) ³ not used ³ 7.000E-07 ³ ---

³ EVSN C14 ³ C-12 evasion flux rate from soil (1/sec) ³ not used ³ 1.000E-10 ³ ---

³ REVSN C14 ³ Fraction of grain in beef cattle feed ³ not used ³ 8.000E-01 ³ ---

³ AVFG4 C14 ³ Fraction of grain in milk cow feed ³ not used ³ 2.000E-01 ³ ---

³ AVFG5 C14 ³ DCF correction factor for gaseous forms of C14 ³ not used ³ 8.894E+01 ³ ---

³ CO2F

³ ³ ³ ³

³ STOR ³ Storage times of contaminated foodstuffs (days): ³ ³ ³

³ STOR ³ Fruits, non-leafy vegetables, and grain ³ 1.400E+01 ³ 1.400E+01 ³ ---

³ STOR_T(1)

STOR ³ Leafy vegetables ³ 1.000E+00 ³ 1.000E+00 ³ ---

³ STOR_T(2)

STOR ³ Milk ³ 1.000E+00 ³ 1.000E+00 ³ ---

³ STOR_T(3)

STOR ³ Meat and poultry ³ 2.000E+01 ³ 2.000E+01 ³ ---

³ STOR_T(4)

STOR ³ Fish ³ 7.000E+00 ³ 7.000E+00 ³ ---

³ STOR_T(5)

STOR ³ Crustacea and mollusks ³ 7.000E+00 ³ 7.000E+00 ³ ---

³ STOR_T(6)

STOR ³ Well water ³ 1.000E+00 ³ 1.000E+00 ³ ---

³ STOR_T(7)

STOR ³ Surface water ³ 1.000E+00 ³ 1.000E+00 ³ ---

³ STOR_T(8)

STOR ³ Livestock fodder ³ 4.500E+01 ³ 4.500E+01 ³ ---

³ STOR_T(9)

³ ³ ³ ³

³ R021 ³ Thickness of building foundation (m) ³ not used ³ 1.500E-01 ³ ---

³ FLOOR1 R021 ³ Bulk density of building foundation (g/cm**3) ³ not used ³ 2.400E+00 ³ ---

³ DENSFL R021 ³ Total porosity of the cover material ³ not used ³ 4.000E-01 ³ ---

³ TPCV R021 ³ Total porosity of the building foundation ³ not used ³ 1.000E-01 ³ ---

³ TPFL

R021 ³ Volumetric water content of the cover material ³ not used ³ 5.000E-02 ³ ---

³ PH2OCV R021 ³ Volumetric water content of the foundation ³ not used ³ 3.000E-02 ³ ---

³ PH2OFL R021 ³ Diffusion coefficient for radon gas (m/sec): ³ ³ ³

³ R021 ³ in cover material ³ not used ³ 2.000E-06 ³ ---

³ DIFCV R021 ³ in foundation material ³ not used ³ 3.000E-07 ³ ---

³ DIFFL R021 ³ in contaminated zone soil ³ not used ³ 2.000E-06 ³ ---

³ DIFCZ R021 ³ Radon vertical dimension of mixing (m) ³ not used ³ 2.000E+00 ³ ---

³ HMIX R021 ³ Average building air exchange rate (1/hr) ³ not used ³ 5.000E-01 ³ ---

³ REXG R021 ³ Height of the building (room) (m) ³ not used ³ 2.500E+00 ³ ---

³ HRM R021 ³ Building interior area factor ³ not used ³ 0.000E+00 ³ ---

³ FAI R021 ³ Building depth below ground surface (m) ³ not used ³-1.000E+00 ³ ---

³ DMFL R021 ³ Emanating power of Rn-222 gas ³ not used ³ 2.500E-01 ³ ---

³ EMANA(1)

R021 ³ Emanating power of Rn-220 gas ³ not used ³ 1.500E-01 ³ ---

³ EMANA(2)

³ ³ ³ ³

³ TITL ³ Number of graphical time points ³ 32 ³ --- ³ ---

³ NPTS TITL ³ Maximum number of integration points for dose ³ 17 ³ --- ³ ---

³ LYMAX TITL ³ Maximum number of integration points for risk ³ 1 ³ --- ³ ---

³ KYMAX

1RESRAD, Version 6.21 T<< Limit = 0.5 year 04/29/2003 18:18 Page 7 Summary : Yankee Rowe Sensitivity Analysis=soil File: YR_Ni-63.RAD Summary of Pathway Selections Pathway ³ User Selection

Å 1 -- external gamma ³ active 2 -- inhalation (w/o radon)³ active 3 -- plant ingestion ³ active 4 -- meat ingestion ³ active 5 -- milk ingestion ³ active 6 -- aquatic foods ³ active 7 -- drinking water ³ active 8 -- soil ingestion ³ active 9 -- radon ³ suppressed Find peak pathway doses ³ active