MONTHYEARJAFP-99-0277, Monthly Operating Rept for Sept 1999 Fpr Ja FitzPatrick Nuclear Power Plant.With1999-09-30030 September 1999 Monthly Operating Rept for Sept 1999 Fpr Ja FitzPatrick Nuclear Power Plant.With JAFP-99-0261, Monthly Operating Rept for Aug 1999 for Jafnpp.With1999-08-31031 August 1999 Monthly Operating Rept for Aug 1999 for Jafnpp.With JAFP-99-0236, Monthly Operating Rept for July 1999 for Ja FitzPatrick Npp. with1999-07-31031 July 1999 Monthly Operating Rept for July 1999 for Ja FitzPatrick Npp. with JAFP-99-0211, Monthly Operating Rept for June 1999 for Ja FitzPatrick Nuclear Power Plant.With1999-06-30030 June 1999 Monthly Operating Rept for June 1999 for Ja FitzPatrick Nuclear Power Plant.With JAFP-99-0181, Monthly Operating Rept for May 1999 for Jafnpp.With1999-05-31031 May 1999 Monthly Operating Rept for May 1999 for Jafnpp.With JAFP-99-0166, Monthly Operating Rept for Apr 1999 for Ja FitzPatrick Nuclear Plant.With1999-04-30030 April 1999 Monthly Operating Rept for Apr 1999 for Ja FitzPatrick Nuclear Plant.With JAFP-99-0142, Monthly Operating Rept for Mar 1999 for Ja FitzPatrick Nuclear Power Plant.With1999-03-31031 March 1999 Monthly Operating Rept for Mar 1999 for Ja FitzPatrick Nuclear Power Plant.With JAFP-99-0092, Monthly Operating Rept for Feb 1999 for Ja FitzPatrick Nuclear Power Plant.With1999-02-28028 February 1999 Monthly Operating Rept for Feb 1999 for Ja FitzPatrick Nuclear Power Plant.With JAFP-99-0011, Monthly Operating Rept for Dec 1998 for Ja FitzPatrick Nuclear Power Plant.With1998-12-31031 December 1998 Monthly Operating Rept for Dec 1998 for Ja FitzPatrick Nuclear Power Plant.With JAFP-98-0396, Monthly Operating Rept for Nov 1998 for Ja FitzPatrick Npp. with1998-11-30030 November 1998 Monthly Operating Rept for Nov 1998 for Ja FitzPatrick Npp. with JAFP-98-0360, Monthly Operating Rept for Oct 1998 for Ja FitzPatrick Nuclear Power Plant.With1998-10-31031 October 1998 Monthly Operating Rept for Oct 1998 for Ja FitzPatrick Nuclear Power Plant.With JAFP-98-0322, Monthly Operating Rept for Sept 1998 for Ja Fitzpatrick Nuclear Power Plant.With1998-09-30030 September 1998 Monthly Operating Rept for Sept 1998 for Ja Fitzpatrick Nuclear Power Plant.With ML20151X6891998-08-31031 August 1998 Monthly Operating Rept for Aug 1998 for Ja FitzPatrick Nuclear Power Plant JAFP-98-0264, Monthly Operating Rept for July 1998 for Ja FitzPatrick Nuclear Plant1998-07-31031 July 1998 Monthly Operating Rept for July 1998 for Ja FitzPatrick Nuclear Plant JAFP-98-0222, Monthly Operating Rept for June 1998 for Ja FitzPatrick Nuclear Power Plant1998-06-30030 June 1998 Monthly Operating Rept for June 1998 for Ja FitzPatrick Nuclear Power Plant JAFP-98-0193, Monthly Operating Rept for May 1998 for Ja FitzPatrick Nuclear Plant1998-05-31031 May 1998 Monthly Operating Rept for May 1998 for Ja FitzPatrick Nuclear Plant JAFP-98-0168, Monthly Operating Rept for Apr 1998 for Ja FitzPatrick Nuclear Power Plant1998-04-30030 April 1998 Monthly Operating Rept for Apr 1998 for Ja FitzPatrick Nuclear Power Plant JAFP-98-0128, Monthly Operating Rept for Mar 1998 for Ja FitzPatrick Nuclear Power Plant1998-03-31031 March 1998 Monthly Operating Rept for Mar 1998 for Ja FitzPatrick Nuclear Power Plant JAFP-98-0091, Monthly Operating Rept for Feb 1998 for JAFNPP1998-02-28028 February 1998 Monthly Operating Rept for Feb 1998 for JAFNPP JAFP-98-0058, Monthly Operating Rept for Jan 1998 for Ja FitzPatrick Nuclear Power Plant1998-01-31031 January 1998 Monthly Operating Rept for Jan 1998 for Ja FitzPatrick Nuclear Power Plant JAFP-98-0009, Monthly Operating Rept for Dec 1997 for Ja FitzPatrick Nuclear Power Plant1997-12-31031 December 1997 Monthly Operating Rept for Dec 1997 for Ja FitzPatrick Nuclear Power Plant JAFP-97-0474, Monthly Operating Rept for Nov 1997 for Ja FitzPatrick Nuclear Power Plant1997-11-30030 November 1997 Monthly Operating Rept for Nov 1997 for Ja FitzPatrick Nuclear Power Plant JAFP-97-0435, Monthly Operating Rept for Oct 1997 for Ja FitzPatrick Nuclear Power Plant1997-10-31031 October 1997 Monthly Operating Rept for Oct 1997 for Ja FitzPatrick Nuclear Power Plant JAFP-97-0375, Monthly Operating Rept for Sept 1997 for Ja FitzPatrick Nuclear Plant1997-09-30030 September 1997 Monthly Operating Rept for Sept 1997 for Ja FitzPatrick Nuclear Plant JAFP-97-0341, Monthly Operating Rept for Aug 1997 for Jfnpp1997-08-31031 August 1997 Monthly Operating Rept for Aug 1997 for Jfnpp JAFP-97-0297, Monthly Operating Rept for Jul 1997 for Ja FitzPatrick Nuclear Power Plant1997-07-31031 July 1997 Monthly Operating Rept for Jul 1997 for Ja FitzPatrick Nuclear Power Plant JAFP-97-0242, Monthly Operating Rept for June 1997 for Ja FitzPatrick Nuclear Power Plant1997-06-30030 June 1997 Monthly Operating Rept for June 1997 for Ja FitzPatrick Nuclear Power Plant JAFP-97-0203, Monthly Operating Rept for May 1997 for Ja FitzPatrick Npp1997-05-31031 May 1997 Monthly Operating Rept for May 1997 for Ja FitzPatrick Npp JAFP-97-0178, Monthly Operating Rept for Apr 1997 for Ja FitzPatrick Nuclear Power Plant1997-04-30030 April 1997 Monthly Operating Rept for Apr 1997 for Ja FitzPatrick Nuclear Power Plant JAFP-97-0126, Monthly Operating Rept for Mar 1997 for JAFNPP1997-03-31031 March 1997 Monthly Operating Rept for Mar 1997 for JAFNPP JAFP-97-0093, Monthly Operating Rept for Feb 1997 for James A. FitzPatrick Nuclear Power Plant1997-02-28028 February 1997 Monthly Operating Rept for Feb 1997 for James A. FitzPatrick Nuclear Power Plant JAFP-97-0056, Monthly Operating Rept for Jan 1997 for Ja FitzPatrick Nuclear Power Plant1997-01-31031 January 1997 Monthly Operating Rept for Jan 1997 for Ja FitzPatrick Nuclear Power Plant JAFP-97-0012, Monthly Operating Rept for Dec 1996 for Ja FitzPatrick Nuclear Power Plant1996-12-31031 December 1996 Monthly Operating Rept for Dec 1996 for Ja FitzPatrick Nuclear Power Plant JAFP-96-0476, Monthly Operating Rept for Nov 1996 for James A. FitzPatrick Nuclear Power Plant1996-11-30030 November 1996 Monthly Operating Rept for Nov 1996 for James A. FitzPatrick Nuclear Power Plant JAFP-96-0448, Monthly Operating Rept for Oct 1996 for Ja FitzPatrick Nuclear Power Plant1996-10-31031 October 1996 Monthly Operating Rept for Oct 1996 for Ja FitzPatrick Nuclear Power Plant JAFP-96-0401, Monthly Operating Rept for Sept 1996 for Jfnpp1996-09-30030 September 1996 Monthly Operating Rept for Sept 1996 for Jfnpp JAFP-96-0352, Monthly Operating Rept for Aug 1996 for Ja FitzPatrick Nuclear Power Plant1996-08-31031 August 1996 Monthly Operating Rept for Aug 1996 for Ja FitzPatrick Nuclear Power Plant JAFP-96-0300, Monthly Operating Rept for Jul 1996 for Ja FitzPatrick Nuclear Power Plant1996-07-31031 July 1996 Monthly Operating Rept for Jul 1996 for Ja FitzPatrick Nuclear Power Plant JAFP-96-0275, Monthly Operating Rept for June 1996 for Ja FitzPatrick Nuclear Power Plant1996-06-30030 June 1996 Monthly Operating Rept for June 1996 for Ja FitzPatrick Nuclear Power Plant JAFP-96-0240, Monthly Operating Rept for May 1996 for Ja FitzPatrick Nuclear Power Plant1996-05-31031 May 1996 Monthly Operating Rept for May 1996 for Ja FitzPatrick Nuclear Power Plant JAFP-96-0196, Monthly Operating Status Rept for Apr 1996 for Ja FitzPatrick Nuclear Power Plant1996-04-30030 April 1996 Monthly Operating Status Rept for Apr 1996 for Ja FitzPatrick Nuclear Power Plant JAFP-96-0156, Monthly Operating Rept for Mar 1996 for Ja FitzPatrick Nuclear Power Plant1996-03-31031 March 1996 Monthly Operating Rept for Mar 1996 for Ja FitzPatrick Nuclear Power Plant JAFP-96-0113, Monthly Operating Rept for Feb 1996 for Ja FitzPatrick Nuclear Power Plant1996-02-29029 February 1996 Monthly Operating Rept for Feb 1996 for Ja FitzPatrick Nuclear Power Plant JAFP-96-0066, Monthly Operating Rept for Jan 1996 for JAFNPP1996-01-31031 January 1996 Monthly Operating Rept for Jan 1996 for JAFNPP JAFP-96-0023, Monthly Operating Rept for Dec 1995 for Ja Fitzpatrick Nuclear Power Plant1995-12-31031 December 1995 Monthly Operating Rept for Dec 1995 for Ja Fitzpatrick Nuclear Power Plant JAFP-95-0535, Monthly Operating Rept for Nov 1995 for Jafnpp1995-11-30030 November 1995 Monthly Operating Rept for Nov 1995 for Jafnpp JAFP-95-0486, Monthly Operating Rept for Oct 1995 for Ja FitzPatrick Nuclear Plant1995-10-31031 October 1995 Monthly Operating Rept for Oct 1995 for Ja FitzPatrick Nuclear Plant JAFP-95-0444, Monthly Operating Rept for Sept 1995 for Ja FitzPatrick Nuclear Power Plant1995-09-30030 September 1995 Monthly Operating Rept for Sept 1995 for Ja FitzPatrick Nuclear Power Plant JAFP-95-0413, Monthly Operating Rept for Aug 1995 for Ja Fitzpatrick Nuclear Power Plant1995-08-31031 August 1995 Monthly Operating Rept for Aug 1995 for Ja Fitzpatrick Nuclear Power Plant JAFP-95-0372, Monthly Operating Rept for July 1995 for Ja FitzPatrick Nuclear Power Plant1995-07-31031 July 1995 Monthly Operating Rept for July 1995 for Ja FitzPatrick Nuclear Power Plant 1999-09-30
[Table view] Category:TEXT-SAFETY REPORT
MONTHYEARJAFP-99-0277, Monthly Operating Rept for Sept 1999 Fpr Ja FitzPatrick Nuclear Power Plant.With1999-09-30030 September 1999 Monthly Operating Rept for Sept 1999 Fpr Ja FitzPatrick Nuclear Power Plant.With ML20217A9931999-09-30030 September 1999 NRC Regulatory Assessment & Oversight Pilot Program, Performance Indicator Data JAFP-99-0261, Monthly Operating Rept for Aug 1999 for Jafnpp.With1999-08-31031 August 1999 Monthly Operating Rept for Aug 1999 for Jafnpp.With JAFP-99-0236, Monthly Operating Rept for July 1999 for Ja FitzPatrick Npp. with1999-07-31031 July 1999 Monthly Operating Rept for July 1999 for Ja FitzPatrick Npp. with ML20216D9541999-07-28028 July 1999 Safety Evaluation Authorizing Proposed Alternatives for Second 10-year Interval Pursuant to 10CFR50.55a(a)(3)(ii) ML20196H8621999-06-30030 June 1999 NRC Regulatory Assessment & Oversight Pilot Program, Performance Indicator Data, June 1999 Rept JAFP-99-0211, Monthly Operating Rept for June 1999 for Ja FitzPatrick Nuclear Power Plant.With1999-06-30030 June 1999 Monthly Operating Rept for June 1999 for Ja FitzPatrick Nuclear Power Plant.With JAFP-99-0175, Annual Summary of Changes,Tests & Experiments for 1997/1998. with1999-06-0202 June 1999 Annual Summary of Changes,Tests & Experiments for 1997/1998. with JAFP-99-0181, Monthly Operating Rept for May 1999 for Jafnpp.With1999-05-31031 May 1999 Monthly Operating Rept for May 1999 for Jafnpp.With JAFP-99-0166, Monthly Operating Rept for Apr 1999 for Ja FitzPatrick Nuclear Plant.With1999-04-30030 April 1999 Monthly Operating Rept for Apr 1999 for Ja FitzPatrick Nuclear Plant.With JAFP-99-0142, Monthly Operating Rept for Mar 1999 for Ja FitzPatrick Nuclear Power Plant.With1999-03-31031 March 1999 Monthly Operating Rept for Mar 1999 for Ja FitzPatrick Nuclear Power Plant.With JAFP-99-0092, Monthly Operating Rept for Feb 1999 for Ja FitzPatrick Nuclear Power Plant.With1999-02-28028 February 1999 Monthly Operating Rept for Feb 1999 for Ja FitzPatrick Nuclear Power Plant.With ML20207E9311999-02-26026 February 1999 Part 21 Rept Re Sprague Model TE1302 Aluminum Electrolytic Capacitors with Date Code of 9322H.Caused by Aluminum Electrolytic Capacitors.Affected Capacitors Replaced ML20202J0891999-02-0303 February 1999 Safety Evaluation Accepting Rev 2 of Third Interval Inservice Testing Program for Pumps & Valves for James a FitzPatrick Nuclear Power Plant ML20199M0891999-01-22022 January 1999 Part 21 Rept Re Failure of Square Root Converters.Caused by Failed Aluminum Electrolytic Capacitory Spargue Electric Co (Model Number TE1302 with Mfg Date Code 9322H).Sent Square Root Converters Back to Mfg,Barker Microfarads,Inc JAFP-99-0011, Monthly Operating Rept for Dec 1998 for Ja FitzPatrick Nuclear Power Plant.With1998-12-31031 December 1998 Monthly Operating Rept for Dec 1998 for Ja FitzPatrick Nuclear Power Plant.With ML20198F9991998-12-0404 December 1998 Assessment of Licensing Basis for Use of Containment Overpressure Credit for Net Positive Suction Head Analyses Power Authority of State of New York,James a Fitzpatrick Nuclear Power Plant ML20196J3501998-12-0404 December 1998 SER Accepting License Response to GL 96-05, Periodic Verification of Design-Basis Capability of Safety-Related Motor-Operated Valves JAFP-98-0396, Monthly Operating Rept for Nov 1998 for Ja FitzPatrick Npp. with1998-11-30030 November 1998 Monthly Operating Rept for Nov 1998 for Ja FitzPatrick Npp. with ML20196F9251998-11-25025 November 1998 Safety Evaluation Re Thrid 10-year Interval Inservice Insp Program Relief Requests for Plant ML20195J7521998-11-18018 November 1998 Rev 7 to Jaf Colr ML20195K4211998-11-17017 November 1998 Safety Evaluation Authorizing Proposed Alternative in Relief Request VRR-05 Per 10CFR50.55a(a)(3)(i) & PRR-01,PRR-02R1, PRR-03,PRR-04,VRR-02,VRR-03 & VRR-04 Per 10CFR50.55a(a)(3)(ii) ML20195E1051998-11-13013 November 1998 Safety Evaluation Accepting Licensee Response to GL 95-07, Pressure Locking & Thermal Binding of Safety-Related Power Operated Gate Valves, Issued 950817 ML20197G6221998-11-0606 November 1998 Non-proprietary Rev 7 to HI-971661, Licensing Rept for Reracking of Ja FitzPatrick Sfp ML20155H5321998-11-0303 November 1998 Safety Evaluation Authorizing Alternative to ASME Code Requirements for CRD Bolting ML20155H5801998-11-0303 November 1998 Safety Evaluation Authorizing Postponement of Beginning of Augmented Exam Requirements of 10CFR50.55a(g)(6)(ii)(A)(2) Re ASME Code,Section XI JAFP-98-0360, Monthly Operating Rept for Oct 1998 for Ja FitzPatrick Nuclear Power Plant.With1998-10-31031 October 1998 Monthly Operating Rept for Oct 1998 for Ja FitzPatrick Nuclear Power Plant.With ML20155C2821998-10-30030 October 1998 Non-proprietary Rev 0 to GENE-187-30-1598 Np, CRD Bolting Flaw Evaluation for Ja FitzPatrick Nuclear Power Plant ML20154L6591998-10-14014 October 1998 Safety Evaluation Accepting Licensee Proposed Alternative to Snubber Visual Inservice Exam Intervals & Sampling Rates Requirements Contained in ASME Code,Section Xi,Subsection Iwf,Article IWF-5000 JAFP-98-0322, Monthly Operating Rept for Sept 1998 for Ja Fitzpatrick Nuclear Power Plant.With1998-09-30030 September 1998 Monthly Operating Rept for Sept 1998 for Ja Fitzpatrick Nuclear Power Plant.With ML20153D2591998-09-21021 September 1998 SER Accepting Proposed Alternative Testing of Containment Following ECCS Suction Strainer Replacement ML20153B5611998-09-0101 September 1998 Rev 1 to JAF-SE-98-013, RHR & Core Spray Suppression Pool Suction Strainer Replacement ML20151X6891998-08-31031 August 1998 Monthly Operating Rept for Aug 1998 for Ja FitzPatrick Nuclear Power Plant ML20237E8361998-08-25025 August 1998 Rev 6 to Colr ML20237E9471998-08-0808 August 1998 Rev 6 to Colr JAFP-98-0264, Monthly Operating Rept for July 1998 for Ja FitzPatrick Nuclear Plant1998-07-31031 July 1998 Monthly Operating Rept for July 1998 for Ja FitzPatrick Nuclear Plant ML20236X5881998-07-29029 July 1998 Safety Evaluation Supporting Amend 245 to License DPR-59 ML20236V8181998-07-29029 July 1998 Safety Evaluation Accepting Request for Relief from Implementation of Requirements of 10CFR50.55a Related to Containment Repair & Replacement Activities for James a FitzPatrick Nuclear Power Plant ML20153B5781998-07-28028 July 1998 Rev 0 to JAF-SE-98-025, HPCI & RCIC Suppression Pool Suction Strainer Replacement ML20236X3831998-07-14014 July 1998 Rev 2 to JAF-RPT-MULTI-02671, Summary of Detailed Evaluation for NRC Generic Ltr 96-06 ML20154L9201998-07-10010 July 1998 SER Accepting Rev to Reactor Vessel Surveillance Capsule Withdrawal Schedule for James a Fitzpatrick Nuclear Power Plant JAFP-98-0222, Monthly Operating Rept for June 1998 for Ja FitzPatrick Nuclear Power Plant1998-06-30030 June 1998 Monthly Operating Rept for June 1998 for Ja FitzPatrick Nuclear Power Plant JAFP-98-0193, Monthly Operating Rept for May 1998 for Ja FitzPatrick Nuclear Plant1998-05-31031 May 1998 Monthly Operating Rept for May 1998 for Ja FitzPatrick Nuclear Plant ML20248F3531998-05-21021 May 1998 Part 21 Rept Re Electronic Equipment Repaired or Reworked by Integrated Resources,Inc from Approx 930101-980501.Caused by 1 Capacitor in Each Unit Being Installed W/Reverse Polarity. Policy of Second Checking All Capacitors Is Being Adopted JAFP-98-0168, Monthly Operating Rept for Apr 1998 for Ja FitzPatrick Nuclear Power Plant1998-04-30030 April 1998 Monthly Operating Rept for Apr 1998 for Ja FitzPatrick Nuclear Power Plant JAFP-98-0128, Monthly Operating Rept for Mar 1998 for Ja FitzPatrick Nuclear Power Plant1998-03-31031 March 1998 Monthly Operating Rept for Mar 1998 for Ja FitzPatrick Nuclear Power Plant ML20217A4631998-03-23023 March 1998 Safety Evaluation Accepting Use of Three Heats/Lots of Hot Rolled XM-19 Matl in Core Shroud Repair Assemblies Re Licenses DPR-16 & DPR-59,respectively JAFP-98-0091, Monthly Operating Rept for Feb 1998 for JAFNPP1998-02-28028 February 1998 Monthly Operating Rept for Feb 1998 for JAFNPP ML20202G9081998-02-0606 February 1998 Safety Evaluation Re Amend to License DPR-59 to Revise TS Tables 3.2-2 & 4.2-2 JAFP-98-0058, Monthly Operating Rept for Jan 1998 for Ja FitzPatrick Nuclear Power Plant1998-01-31031 January 1998 Monthly Operating Rept for Jan 1998 for Ja FitzPatrick Nuclear Power Plant 1999-09-30
[Table view] |
Text
.
OPERATING DATA REPORT DOCKET NO. 50-333 DATE Oct. 1983 COMPLETED BY J. Cook TELEPHONE (119342-3840 OPERATING STATUS FitzPatrick Notes
- 1. Unit Name:
- 2. Reponing Period: 830901-830930
- 3. Licensed Thermal Power (MWt): 7416
- 4. Nameplate Rating (Gross MWe): 883
- 5. Design Electrical Rating (Net MWe): 821
- 6. Maximum Dependable Capacity (Gross MWe):
830
- 7. Maximum Dependable Capacity (Net MWe): R1n
- 8. If Changes Occur in Capacity Ratings (Irems Number 3 Through 7) Since Last Report. Give Reasons:
None
- 9. Power Level To Which Restricted,if Any (Net MWe): None
- 10. Reasons For Restrictions.lf Any:
This Montis Yr to-Date Cumulative I1. Hours in Reporting Period 720 6551 71688
- 12. Nuraber Of Hours Reactor Was Critical 673.2 4064.1 50319.8
- 13. Reactor Reserve Shutdown Hours 0 0 0
- 14. Hours Generator On-Line 622.7 3975.7 48990.9
- 15. Unit Reserve Shutdown Hours n n n
- 16. Gross Thermal Energy Generated (MWHj 1237056 8907000 102430858
- 17. Gross Electrical Energy Generated (MWH) 400370 2998850 35433630
- 18. Net Electrical Energy Generated (MWH) 386875 2905655 33770040
- 19. Unit Service Factor a c. Sv 60.7% 68.3%
- 20. Unit Availability Factor 86.5% 60.7% 68.3%
l 21. Unit Capacity Factor (Using MDC Net) 66.3% 54.8% 61.8%
- 22. Unit Capacity Factor (Using DER Net) _ 65.4% 54.0% 57.4%
- 23. Unit Forced Outage Rate 0 7.8% 15.1%
- 24. Shutdcwns Scheduled Over Next 6 Months (Type. Date,and Duration of Each):
i
{
- 25. If Shut Down At End Of Report Period. Estimated Date of Startup:
- 26. Units In Test Status (Prior to Commercial Operation): Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION
, 8310120435 830930 gh i PDR R ADOCK 05000333 '
! PDR
AVERAGE DAILY UNIT POWER LEVEL DOCKET NO. 50-333 UNIT FitzPatrick DATE October 1983 COMPLETED BY J. Cook TELEPHONE (11SY342-1840 September 1983 MONTH DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe Net) (gwe. Net) 3 0 736 17 2 0 33 768 3
10 769 39 37 769 4 20 5 64 21 770 6 173 773 7 216 23 745 8 251 24 601 9 41 3 25 726 10 575 26 777 660 779 12 599 28 782 13 584 29 14 622 780 30 15 638 3 16 725 Summary: The FitzPatrick plant returned to service on 830903 following the fifth refueling outage.
DOCKET NO.
50-333 UNITSHUTDOWNS AND POWER REDUCTIONS UNIT NAME FitzPatrick DATE october 1983 COMPLETED BY J. Cook REPORTMONTH Serstember TELEPilONE (3157342-3840 r.
b C
No. Date g
.! E 3g g j .Y E jg5 Licensee ,Eg je. Cause & Corrective H
i Event p o3 Action to
$$ 35cg e
Report # mO u$ U Prevent Recurrence O
8 830603 s 46.8 c 1 N/A N/A N/A Refueling outage (cumulative hours 2189.4)
I 2 3 4 F: Forced Re .on: Method:
S: Scheduled Exhibit G - Inst ructions A Equipment Failure (Explain) I-Manual for Preparation of Data B Maintenance of Test 2 ManualScram. Entry Sheets for Licensee C Refueling 3 Automatic Scram.
D Regulatory Restriction Event Report (LER) File (NUREG-4-01her (Explain) 0161)
E-Operator Training & License Examination F Administrative 5 G-Operational Error (Explain)
Il-Other (Explain) Exhibit I - Same Source
f NEW YORK POWER AUTHORITY JAMES A. FITZPATRICK NUCLEAR POWER PLANT NARRATIVE
SUMMARY
OF OPERATING EXPERIENCE SEPTEMBER 1983 The refueling outage was completed on September 3, 1983. The unit was returned to service at approximately 2130 hours0.0247 days <br />0.592 hours <br />0.00352 weeks <br />8.10465e-4 months <br />. Power was increased at the preconditioned rate.
At the end of the reporting period the unit is operating at approx-imately 780 MWe.
9
, - - , - - - ,. ,ry,. ,,,a._ - - - - - ,-,-
, JAMES A. F112PATRICE N'JCLEAR POWER PLANT POWER AUTil0RITY OF Tl!E STATE OF NEW YORK REFUELING INFdRMAf10N
- 1. The date of the next scheduled refueling outage is February ,19 85 -
- 2. The scheduled date for restart following refueling is May _19_85
- 3. Will refueling' or resumption of operation thereafter require a technical specification change or other license amendment?
'YES X' If yes, describe in general what these will be and go to question S.
New Minimum Critical Power Ratio operating limits may be required. If new fuel enrichments are introduced, New Maximum Average Planar Linear Heat Generation Limits will be required.
If no, answer question 4. .:
. NO
- 4. ANSWER ONLY IF ANShER TO 3. ABOVE IS NO.
!!as the reload fuci design and core configuration been reviewed by the Plant Safety Review coiamittee to determine whether any unreviewed safety questions are associated ,
with the core reload (Ref.10 CFR Section 50.59)?
YES
,19 NO ,The next scheduled review date is __.
S. ANSWER ONLY 1F ANSWER TO 3. ABOVE IS YES.
The scheduled date for submitting proposed licensing action and supporting information is January ,19 85 .
- 6. Answer the following important licensing considerations YES NO New fuel design? X a) X b) New fuel supplier?
Are there any new unreviewed design or performance analysis methods? X c).
d) Are there any new operating procedures?
Other
[}X(
e) _g-
.Specify: _,
- 7. There are' normally 560 fuel assemblies in the core during operation, present ly there are- 566 in the core.
S. a) There are 626 fuel assemblies of the licensed allowable 2244in the spent fuel pool.
b) An increase in the licensed storage capacity:
X is not.being contemplated at this time.
is not planned at this time, for an additional fuel assemblies.
has been requested for. an additional fuel assemblies.
- 9. ' December ,19 90 is the last possible refueling date that can be Frojectedat this time given the presently licensed spent fuel pool storage capacity.
POWER AUTHORITY OF THE STATE OF NEW YORK -
JAMES A. FITZPATRICK . NUCLEAR POWER PLANT p MAINTENANCE
SUMMARY
I&c sentember 1'983 E :
CAUSE OF RESULTS OF ACTION TAKEN REPAIR DATE SYSTEM -WORK REQUEST # H D CTED TO PRECLUDE TIME i
COMPONEN1 # MALFUNCTION MALFUNCTION RECURRENCE HOURS .
25278 OPS 11 Acoustic Monitor Alarm did not Replaced w/ 2 9/3/83 02 spare l
l RV-71H ,
malfunction clear 1
Normal wear Pen does not Tightened drive 3 9/4/83 02 25284 OPS TR-165 drive clutch
. \
9/9/83 02 26380 JIC Switch malfunction Flo switch out Replaced switch 8 l DPIS-Il6D of Tech Specs & retested 26394 JIC Leak / Age MSL HI Flo/ Leak' Beplaced valve 8 9/8/83 02 pking on low side DPIS-ll7A on 3 valve man 02-3 28231 OPS Broken wire on Recorder won't Replaced broken 4 9/12/83 !
LR-98 chart drive sw drive chart wire i'
25266 OPS Bad Q16 Rod ind full in Changed Q16 8 9/28/83 03 l ROD-22-03 when full out 9/4/83 03 25285 OPS Open circuit in Rod full in ind Inserted 34-07 2 ROD-34-07 rod indication malfunctions full in 9/4/83 03 25286 OPS Short in indicator Rod full in Replaced rod 2 ROD-18-43 indicator shorted indicator module 9/4/83 03 25287 JIC A0V's out of Valves didn't Readjust A0V 2 -
A0V-35,39 adjustment operate 30 see stroke times 9/4/83 05 25291 OPS All rods not full Mode switch Inserted rod 2 RMCS in power sel ignored 34-07 Low gross fail Unit inop or Adjusted low 10 9/1/83 05 27377 OPS RPS-ATTS needed adjust gross fail alarms gross fail alarm
I POWER AUTHORITY OF THE STATE OF NEW YORK JAMES A. FITZPATRICK NUCLEAR POWER PLANT' -
E a
f.
= '
_ MAINTENANCE
SUMMARY
I&C September 1983 A j
. 4 !+
DATE SYSTEM WORK REQUEST #
H .D'ETECTED CAUSE OF RESULTS OF ACTION TAKEN ,
REPAIR j, COMPONENT # MALFUNCTION MALFUNCTION TO PRECLUDE TlME l-RECURRENCE HOURS s-
'I . ,
)!
m9/7/83, 06 25301 i JIC
~
i Out of Low output Adjusted zeros & 40 p
- f' FT-51A,C ,i calibration calibrated j}
w 'R' 9/20/83 06 26382
' JIC. Age e '
v ,j$t Ele:n e control Replaced gemac 4
- " PA-104 / Malfunctions shorted diode ;.
't '
9/L3/B3 06 26302 .>
~
,< JIC Instrument drift Possible ,
Performed static 48 j-FT-50A,B <
f instrument drif t alignment j
s 9/15/83 06- 28245 ,
/ / OPS Bad capacitor on Recorder failed Replaced bad 20 -
,[
FR-96 "
amp board high capacitor e i ~ '
9/20/83, 06 28358 JIC. Age
~
Difference in / Repl ind A,B/ 24 LI-94A,B,C --
'fdwtr level. ind'
^
calibrated A,B,C i r e
., j J . . , , , l' 8/2/53 07 21429 , - ' OPS / ' Broken wire in' 'G-IRM bus no Soldered broken 4 ;'
L-IRM > preamp' response b
,- r
< wire 9/1/83 07 26374 _
> JIC Faulty LPRK cable CabledonNector Replaced connector 3 3 LPRM-28-21 , ' connector faulty'
,,9/1/83 07 27384 '
Cable jaramed at H-IRM won't drive
- .s ,0PS Repaired IRM b. k
'(
H-IRM -
d gear' box out of core
' ' .s.
9/26/83 07 27399 - OI S S Bad connector @ Won't indicate 4epaired' connector 16 H-IRM [. .
drive gear unit full in core in unit '
9/22/83 10 21499 '
OPS Timing adjustment ST-2A requires =5 Adjusted relay to 0.5 -
AK-45A chance min. nor =3 be e5 min 9/9/83 10 28310 OPS Burned-out'11ght Switch won't Replaced light 10 LS-105A bulbs reset bulbs
- l l
]* e
o ,
e,
< , i (; {
POWER AUTHORITY OF THE STATE OF NEW.. YORK -
JAMES A. FITZPATRICK NUCLEAR POWER PLANT .o MAINTENANCE
SUMMARY
I&C September 1983 :
i WORK REQUEST # CAUSE OF RESULTS OF ACTION TAKEN REPAIR DATE SYSTEM H D UECTED TO PRECLUDE TIME COMPONENT # MALFUNCTION MALFUNCTION ,
RECURRENCE HOURS i 9/1/83 13 21431 , OPS Loose screw Solenoid' won't Tightened screw 30 i LS-74 deenergize f-9/26/83 14 26398 JIC Bad light bulb Lo-lo-lo lamp Replaced light 3 DS-24A defective' bulb
.j f -'
9/14/83 '14 ~ 26400 JIC Incorrect contact Relay energized Adjusted relay 6 14A-K6B closure continuously !
l 9/9/83 16-1 25299 OPS Battery expired Recorder reads Replaced battery 24 !
DPR-200 '
too low 9/9/83 17 26393 JIC New setpoints Perform F-IP-17.1 None 12 !
RM-50B for monitor 9/29/83 17 27768 OPS Alarm drift A stack rad monitoc Performed steps 2 ,
RM-50A inoperable of IMP-17.1 !
9/16/83 17 28263 OPS None Check source Pulled S.D.- - 6 RIS-452B drive won't go in bench tested OK l 9/15/83 23 25300 JIC Out of cal- - Difference bet Perform ISP 29 & 4 LT-201A,BC Water in dry side level ind 29-1 9/12/83 27 25295 OPS Defective Amp, Inaccurate Replaced amplifier 6 AZ-101B Fan motor reading Fan motor 9/23/83 27 28211 RES Worn out Repl rec ink pad Replaced print 10 RR-104A & print wheel wheel 9/23/83 29 27679 OPS Switch maladjuste<iSW for 29-A0V-86B Readjusted switch 6 LS-5,7 didn't reset per ISP-65-1 A
4 POWER AUTHORITY OF THE STATE OF NEW YORK JAMES A. FITZPATRICK . NUCLEAR POWER PLANT '
e:
.* t
- MAINTENANCE
SUMMARY
i) T&C September 1983 :
1-0 WORK REQUEST # CAUSE OF RESULTS OF ACTION TAKEN REPAIR
[
DATE SYSTEM COMPONENT #
H DUECTED MALFUNCTION MALFUNCTION yy E T
9/20/83 68 26378 JIC Age /Use Print head cable Replaced print 32 i I. TR-103 , needs replace head cable j
. t-9/13/83- 71 28246 OPS Bad computer pt Computer pt C172 Rechecked / worked 8 i,. Computer indication reads low properly ;
l 9/15/83 76 25267 OPS- Faulty multiplxr Hi temp alarm did Multiplexer 0 i
- HI TMP ALM on other unit not energize repaired /other WR !
9/12/83 76 28230 OPS Defective DC-DC Alarm won't clear Replaced defectiv. s 8 [
ZH-30 converter when reset converter
, 9/13/83 76 28321 OPS Defective power General communica- Replaced power 12 ;
MPX #3 supply tions failure supply i t
l 9/26/83 93 28364 OPS Level indicator Level ind close Cal LT-101D, 8 [
LI-101D out of cal to out of tolr LI-101D L&R L i
1 ;
4 9
_ m l
p .
POWER AUTHORITY OF THE STATE OF NEW YORK
' JAMES A. FITZPATRICK NUCLEAR POWER PLANT SAFETY RELATED ELECTRICAL a MECHANICAL LiAINTENANCE
SUMMARY
t S
DATE SYSTEM HOW DETECTED CAUSE OF MALFUNCTION ACTION TAKEN TO PRECLUDE RECURRENCE T l '9/3 00 20132 N/A No' Malfunction Removed tape from electrical 3 l 02A0V-39 connections & re-spliced l
8/23 02 22896 Routine facility air supply Replaced fittings 4 RV71F Surveill. .
9/7 03 2829'6 Surveill. Ground iri Condolet Reinsulated splice 6 CRD 09-16 Testing 8/27 02 22961 Hydro Pilot Base to Main Replaced gasket 160 RV71C Body Leak 9/6 10 27358 Visual Body-Bonnet Leak Replaced gasket 434 ADV-68A ,
Replaced handle 2 9/6 10 26918 OPS Limitorque Handle -
. MOV-150 Missing 25274 Br'oken Lamp Socket Replaced socket 2 9/12 13 OPS DS45 9/6 23 25559 Visual Broken Seallite Cut back seallilte 4 LT201A e
~
POWER AUTHORITY OF THE STATE OF NEW YORK JAMES A. FITZPATRidK NUCLEAR POWER PLANT SAFETY RELATED ELECTRICAL a MECHANICAL MAINTENANCE
SUMMARY
~
DATE SYSTEM WORK REQUEST # HOW DETECTED REPAIR CAUSE OF MALFUNCTION ACTION TAKEN TO PRECLUDE RECURRENCE TIME HOURS
.9/12 70 26810 OPS N/A Took vibration readings and 4 AHU3A checked bearings 9/8 71 22891 N/A N/A Watered Batteri~es 12 SBA&B '
9/16 10 28355 OPS Pinion gear key Replaced motor, gear;& key 22 1/2 MOV-258 fell out 9/23 13 28389 OPS De'fective relay Replaced relay 9 Motor Control Circuit 9/26 13 28243 OPS Missing Handwheel Replaced handwheel 3 RC1-40 9/27 23 27647 OPS Position switch Replaced position switch 6 A0V-43 malfunction 9/26 27 4630 OPS "0" Ring Leak Replaced "0" ring - pumped down 64 TH78 insulating vacuum 9/25 71 27735 OPS Bad circuit board Replaced circuit board 18 INV 3B
y . _ . - - _
James A. F taPa*.rtek
, Nuclear Poe'er PW
/. P.O. Box 41
- Lycoming, New Wrk 13093 315 342.3840
- > NewYorkPbwer 4# Authority October 6, 1983 JAFP-83-1021 Director, Office of Management Information & Program Control United States Nuclear Regulatory Commission Washington, D.C. 20555
REFERENCE:
Docket No. 50-333
Dear Sir:
The Operating Status Report for the monch of September, 1983 is enclosed. The refueling information has been updated and is enclosed with report.
If there are any questions concerning this report, contact John Cook at (315) 342-3840, Ext. 439.
Very truly yours, h N. -
CAM:JPC:rv Corbin A. McNeill, Jr.
Enclosures i i L
._ _ -