APPENDIX U.S. NUCLEAR REGULATORY COMMISSION
REGION IV
NRC Inspection Report:
50-498/88-49 Operating License:
NPF-76 50-499/88-49 Construction Parmit:
CPPR-129 Dockets:
50-498 50-499 Licensee:
Houston Lighting & Power Company (HL&P)
P.O. Box 1700 Houston, Texas 77001 Facility:
SouthTexasProject(STP), Units 1and2 Inspection At:
STP, Matagorda County, Texas Inspection Conducted: August 15-19, 1988 Inspectors:
d O - s>
F-M. - 5'?
/A-L. D. Gilbert, R7a~cToi'Tnspector, Paterials Date and Quality Prcgrams Section, Division of Reactor Safety 7 -d d. - 6 9 h D. L. Garrison,~ResWestlnspector,~7roject Date
~
-
Section D, Division of Reactor Projects 7 ^,%,, u
.
f - u - sT Approved:
v.
,
T.~Friiers. thTeT,~FaTelTaKEd-Qual t ty MYe
--
Programs Section, Division of Reactor Safety
$$$"$$o$ b ).[
a
-
.
.
f O
g
,
Inspection Sumary Inspection Conducted Augus_t 15-19, 19_8_8 (Report 50-498/_88-49)__
_
Areas Inspected:
No inspection of Unit I was conducted.
Results: Not applicable.
Inspection Conducted August _ 15_-19_,1_9_8_8 (Report 50-499/88,49]
__
_
Areas Inspected:
Routine, unannounced inspection of piping systems for as% uilt verification in Unit 2.
Results: Within the area inspected, no violations or deviations were identified.
.
-
-
-
-. - -
.
.
.
.
_ _ _ _ _ _ - _
_ - -. __
'
-
o.
.
7,
...
-3-
'
l
,
DETAILS l
!
,
1.
Persons Contacted HL&P
-
!
!
- J. T. Westermeier, Project Manager
'
- T. J. Jordan, Project Quality Assurance Manager
- A. W. Harrison, Supervisory Engineer
>
- S. B. Patel, Senior Construction Engineer
- G. Ondriskt, Startup Engineer i
- S. D. Phillips, Project Complianca Engineer l
- K. M. O'Gara, Project Compliance Engineer
!
- R. R. Hernandez, Discipline Site Engineer BechtelEnergyCo_rporation(BECJ f
__
i
- R. D. Bryan, Construction Manager
>
F. Almeida Engineering ABR Group Supervisor NRC i
- J. I. Tapia, Senior Resident Inspector The NRC inspectors also interviewed other contractor personnel during the inspection.
- Indicates personnel attending the exit interview.
Pipo,i,ng Syst_ ems _ As-Built Verification for Unit 2 (37051)
2.
i n
The licensee is using Standard Site Procedures SSPc34 and 39 for the generation and corrpletion of as-built design docurrents for piping and supports. The as-built drawings are scheduled to be completed by December 1, 1988.
Initial NRC inspection of the Unit 2 as-built verification of piping systems is docurrented in NRC Inspection Report 50-499/87-58. The NRC inspectors selected five additional isometric drawings of safety-related piping systems to verify that the as-built drawings correctly reflected the as-built condition of the piping systems as installed in the plant.
The following isometric drawings were selected as a representative sample of the piping systems:
Isoretric Drawing 2M369PCV217. Sheet A01, Revision 6. for the o
chemical and volurre control (CV) system piping from Penetration M51 to MS2 which included approximately 120 feet of 2-inch diameter Class 2 piping, 24 valves, and 8 pipe support.
-
.-
-
_.
=_
.
.-
C,
-
.
-4-l
o Isometric Drawing 2M369PRH259, Sheet 02, Revision 4. for the residual l
heat removal (RH) system piping from Penetration M55 to M76 which
'
included approximately 57 feet of 8-inch diameter Class 2 piping,
'
2 valves, and 3 pipe supports.
'
o Isometric Drawing 5F369PFC530, Sheet 01, Revision 6. for the spent
!
fuel pool cooling and cleanup (FC) system piping from the FC pump to the FC heat exchanger which included approximately 30 feet of 10-inch
,
>
diameter Class 3 piping, 1 valve, and 2 pipe supports.
o Isometric Drawing 2F369PS!572, Sheet 05, Revision 8 for the safety f'
injection (SI) system piping from the high head SI pump to Support RR39 which included approximately 27 feet of 6-inch diameter i
Class 2 piping and 4 pipe supports.
l o
Isometric Drawing 5F369PCS515 Sheet 03, Revision 7, for the containment spray (CS) system piping from the CS pump to Weld FW5396
!
which included approximately 85 feet of 3 and 8-inch diameter Class 2
!
piping, 1 valve, and 11 pipe supports.
l
[
In the area inspected, the as-built condition of the installed piping and
!
supports was consistent with the drawings and piping specifications for
!
piping location, size, and configuration; pipe weld location and
-
identification; and support location, type, and configuration.
j No violations or deviations were identified.
3.
Exit Interview The NRC inspectors met with the licensee representatives denoted in paragraph 1 on August 19, 1988, and sunmarized the inspection scope and
!
findings.