JAN I 31987

,

In Reply Refer To:

Docket: STN 50-482/86-19 Wolf Creek Nuclear Operating Corporation ATTN: Bart D. Withers President & Chief Executive Officer P. O. Box 411 Burlington, Kansas 66839 Gentlemen:

In accordance with our letter of December 8, 1986, we are responding to your reply to Violation 482/8619-03 contained in your letter of October 22, 1986.

We have performed the backfit determination that you requested and concluded that the NRC position on reportability has not changed and the reporting requirement identified in Violation 482/8619-03 is not a backfit.

Neverthe-less, we believe inspector actions may have contributed to confusion regarding the acceptance of your classification of the event and the associated reporting requirements and, therefore, we are withdrawing Violation 482/8619-03.

A detailed respnnse to your reply is contained in the attachment to this letter. The material enclosed herewith contains Safeguards Information as identified by 10 CFR 73.21 and its disclosure to unauthorized individuals is prohibited by Section 147 of the Atomic Energy Act of 1954, as amended.

Therefore, the material will not be placed in the Public Document Room Should you disagree with our determination of this matter, KG&E has the right to appeal this decision in accordance with 10 CFR 50.109 and Manual Chapter 0514, Section 0514-044 Please contact Mr. Larry Yandell at 817/860-8108 if you have any questions regarding this matter.

Sincerely, Original signed by::

Robert D Martin 8701160072 870113

~

PDR ADOCK 05000482 Robert D. Martin Q

PDR Regional Administrator Attachment:

As stated ENCLOSURE CONTAINS cc w/o safeguards:.

Wolf Creek Nuclear Operating Corporation UPON SEPARATION THIS ATTN: Otto Maynard, Manager PAGE IS DECONTROLLED.

of Licensing P. O. Box 411 Burlington, Kansas 66839 Y

/S$

,//

J

RIV:C:dPS C:RLSPB D:D

[C:RPB/B DNPB

'D:DRSP LAYandi cd WLF H11%q RL a artpl0RHuntern,/p/86";1/p/86 ou/ y/86 rJEGagliardo EHJohnson

&/$/86 g /g/8j n/}1/86

,

E0 8 RC h DAPowers WLBrown

[y

/ /5 /87

) /1/86 1g

p-

,

a Kansas Gas ~and Electric Company-2-cc: (Cont'd)

Gary _ Boyer, Plant Manager Wolf Creek Nuclear Operating Corporation P. O. Box 411 Burlington, Kansas 66839 Forrest Rhodes, Plant Superintendent Wolf Creek Nuclear Operating Corporation.

P. O. Box 411 Burlington, Kansas 66839 Kansas Radiation Control Program Director bec w/ safeguards:

V. Stello, EDO RIV Security File G. McCorkle, NMSS J. Gibson, SSPD/NRR IE File Resident Inspector R. D. Martin, RA Security Inspector Chief, EP&SPS R. L. Bangart, DRSS D. A. Powers bc5 w/o safeguards:

M B IE-04 MIS RPB D. Weiss, LFMB (AR-2015)

Section Chief (RPB/B)

RIV File RSTS Operator W. L. Fisher, R&SPB R&SPB M;rron Karnan, ELD, MNBB J. Harrison, RIII E. H. Johnson, DRS&P Project Inspector (RPB/B)

.

W. L. Brown

_

ENCLOSURE COBRAINS

'

SAFEGUARDS INFORMATiON.

UPON SEPARATION Tht3 PAGE IS DECONTROLLED.

l l

l l

,

- '$

"

WHEN SEPARATED FROM

,

'

' ENCLOSURES HANDLE KANSAS GAS AND ELECTRIC C0hWANY THIS DOCUMENT AS DECONTROLLED.

"* ""c"*C C"'"

S L E N N L st O E S T E R

, WeC8 P.EseOEse7 souCLEAa October 22, 1986 I@BDVB >

Mr. E. H. Johnson, Director Division of Reactor Safety and Projects U.S. Nuclear Regulatory Commission OCT 2 9 m Region IV 611 Ryan Plaza Drive, Suite 1000 y

-

Arlington, Texas 76011 KMLNRC 86-194 Re:

Docket No. S?I 50-482 Subj:

Response to Inspection Report STN 50-482/86-19

Dear Mr. Johnson:

This letter is written in response to your letter of Septecber 26, 1986, which transmitted Inspection Report STN 50-482/86-19.

As requested, the violations (482/8619-01, 02, and 03) identified in the Inspection Report are being addressed in four parts, i

(a) The reason for the violations if admitted; i

i j

(b) The corrective steps which have been taken and the results

!

achieved; i

(c) Corrective steps which will be taken to avoid further violations; and

!

(d) The date when full compliance will be achieved.

,

!

Kansas Gas and Electric Company (KG&E) believes that violation 8619-03 o

resulted from a change in interpretation of 10 CFR 73.71(c) by the KRC b

Region IV inspectors.

In accordance with 10 CFR 50.109 "Backfitting" and NRC Manual Chapter 0514 "NRC Program for Management of Plant-Specific Backfitting of Nuclear Power Plants",

KG&E requests that NRC Region IV

,

perform a backfit determination on this change.

Supporting rationale for this request is included in the attached response to the violation.

KG&E j

believes this request is consistent with Mr. Stello's March 3, 1986, letter

,

to Mr. Wilson Cadman which encouraged utilities to become familiar with the l

backfit process and to identify potential backfit items.

!

l

.

Attachment A contains Safeguards Information in accordance with 10 CFR 73.21 and therefore should be withheld from public disclosure. This letter, when seperated from the attachment does not contain Safeguards Information and should be handled as decontrolled.

lN N

201 N. Market - McMe, Kenees - Met Address:RO. Box 200 i Nchmn, Kanses 67201 - Te6ephone:Aree Code (316) 261-6451

_ _ _ _ _ _

.--

. _ _ _ _

t

_

,,y g

.[

,

^

Mr. E. H. J:hnson October 22, 1986

.

KMLNRC 86-194 Page 2 If you have any questions concerning this matter, please contact me or Mr.

O.

L.

Maynard of my staff.

Acknowlegement of receipt of this letter by

,

signing the enclosed receipt form and returning it to KG&E would be appreciated.

Yours very truly,

!

Glenn L. Koester Vice President - Nuclear GLK:see Attachment oc: P0'Connor (2), w/o JCumains, w/o JTaylor, w/a l

!

l l

!

l

.

WHEN SEPARATED FROM ENCLOSURES. HANDLE THIS DOCUMENT AS DECONTROLLED.

. _ _..

-

_ - -. _

. ---- -

.

.

-

--

.

_. _

.