Preoperational Security Program Review 50-410/86-24 on 860512-16.Program Implementation on Schedule.Major Areas Inspected Status of Security Program & Licensee Action on IE Notices,Circulars & Bulletins
ML17055C150
Person / Time
Site: Nine Mile Point 
Issue date: 07/29/1986
From: Keimig R, Martin W, Galen Smith
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML17055C149 List:
References
50-410-86-24, IEIN-84-08, IEIN-84-8, IEIN-85-028, IEIN-85-28, NUDOCS 8608040202
Download: ML17055C150 (12)


Text

U.S.

NUCLEAR REGULATORY COMMISSION

REGION I

Report No.

50-410/86-24 Docket No.

50-410 License No.

CPPR-112 Licensee:

Nia ara Mohawk Power Cor 300 Erie Bovelvard West S racuse New York 13202 Facility Name:

Nine Mile Point Unit ¹2 Inspection At:

Scriba New York I

  • I I 6: ~d-I Type of Inspection:

Prep erational Ph sical Securit Pro ram Review Date of Last Program Review:

December 16-19 1985 Inspectors:

. Marti

,

Ph sical S cu ty Inspector date G.

C. Smith, Security Specialist dat Approved by:

R. Keimig Chief, eguards Section date Ins ection Summar

Pre erationa Securit Pro ram Review conducted on Ma 12-16 1986 50-410/86-24 Areas Reviewed:

Status of Security Program in the areas of:

Testing and Maintenance; Physical Barriers (Protected and Vital Areas); Security System Power Supply; Lighting; Assessment Aids; Access Control (Personnel, Packages and Vehicles); Detection Aids (Protected and Vital Areas);

Alarm Stations; Communications; Security Contingency Plan; Licensee action on NRC Information Notices, Circulars and Bulletins and Inspector Follow-up Items.

Results:

Implementation of the program was found to be on schedule.

0>02 86p7gp PDR ADOCK 050004iP

$ 8

.

PDR

DETAILS Persons Contacted R.

F. Orr, Supervisor, Nuclear Security J.

P. Beratta, Assistant Supervisor, Nuclear Security D.

K. MacVittie, Nuclear Security Specialist E.

W. Pearson, Technical Assistant, Nuclear Security R. A. Gramm, USNRC, Senior Resident Inspector T. S. Farrell, Stone and Webster Engineering Supt.

The inspectors also interviewed other licensee personnel including members of the proprietary security force.

30703 Exit Interview The inspectors met with the licensee personnel listed in Paragraph 1 at the conclusion of the review on May 16, 1986.

At that time the findings of the review were presented'ritten material was not provided to the licensee by the inspectors at any time during the review.

92701 Status of Ins ector Follow-u Items The following is a

summary of the status of inspector follow-up items in the area of physical security as of this review (50-410/86-24).

Items closed during this review are discussed in the body of this report.

Item No.

Review Module Status 84-10-01 84-10-02 84-10-03 84-10-04 84-10-05 84-10-06 84-10-07 84-10-08 84-10-10 84"10-11 84-10-12 84-10-13 84"10-14 84-10-15 84-10-16 84-10-17 84-10-18 PS Plan and Implementing Procedures Security Organization Security Organization Security Organization Security Program Audit Records and Reports Testing and Maintenance Locks, Keys, and Combinations Physical Barriers (Protected Area)

~ Physical Barriers (Vital Areas)

Security System Power Supply Lighting Assessment Aids Access Control (Personnel)

Access Control (Packages)

Access Control (Vehicles)

Detection Aids (Protected Area)

Cl osed (85-48)

Closed (85-48)

Closed (85-48)

Closed (86-24)

Closed (86-24)

Closed (86-24)

Closed (86-24)

Closed (85-48)

Closed (86-24)

Open Closed (86-24)

Closed (86-24)

Open Closed (86-24)

Closed (86-24)

Open Closed (86-24)

84-10-19 84-10-21 84-10-22 84-10-23 84-10-24 84-10-25 Detection Aids (Vital Areas)

Alarm Stations Training and Qualification Plan Security Contingency Plan Security Contingency Plan Independent Inspection Effort-Action on NRC Bulletins, Circulars and Information Notices Open Closed (86-24)

Closed (85-38)

Closed (86-24)

Closed (86-24)

Closed (86-24)

81022 Securit Or anization Mana ement The inspectors'eview of the security organization revealed a fully staffed management organization,,including shift supervisors.

The ins-pectors found that the security force has been fully trained, but was not armed at the time of the review.

No discrepancies were identified.

Inspector Follow-up Item 50-410/84-10-02 is closed.

The licensee's Safety Review and Audit Board (SRAB) performed a compre-hensive audit of the Nine Mile Point 2 security program on March 31 April 4, 1986.

Several recommendations for program enhancements, con-tained in the audit report, had been acted upon by the licen"ee.

No discrepancies were identified.

Inspector Fol low-up Item 50-410/84-10-05 i s closed.

81038 Records and Re orts The inspectors reviewed the record and report forms and implementing procedures that have been modified to combine the Unit 2 security equip-ment and facilities with the existing Unit 1 record and report system when the security at Units 1 and 2 are combined into a single program.

The modifications are adequate and appropriate for their intended purpose.

All records and reports reviewed by the inspectors were in accordance with the licensee's NRC-approved security plan.

Inspector Follow-up Item 50-410/84-10-06 is closed.

81042 Testin and Maintenance The inspectors noted that the licensee has established a dedicated security testing and maintenance section which is well staffed and res-ponds promptly to security equipment problems based on priorities esta-blished by security management.

This was confirmed by the inspectors through a review of records.

Inspector Follow-up Item 50-410/84-10-07 is close.

81052 Ph sical Barriers Protected Area The. inspectors observed that the licensee maintained the barrier sur-rounding the protected area in accordance with the NRC-approved security plan.

The inspectors noted that the licensee has completed a survey of water drains and tunnels and had provided suitable barriers wherever required.

Inspector Follow-up Item 50-410/84-10-10 is closed.

9.

81054 Ph s ical Barriers Vital Areas The inspectors noted that, although the licensee had completed the vital area review, the installation of barrier s at vital area penetrations was not yet complete.

Inspector Follow-up Item 50-410/84-10-11 remains open.

10.

81058 Securit S stem Power Su

The inspectors determined by a review of records that the licensee had conducted a simulated load test of the security system power supply at the rated load of security related equipment in October of 1985.

The current load is approximately 40 percent of the rated capacity of the power supply system.

The results of these tests indicated that the security system power supply is adequate.

Inspector Follow-up Item 50-410/84-10-12 and -25 are closed.

U. ~Li The inspectors observed that the lighting in the isolation zones and protected area met the requirements of the NRC-approved security plan and was adequate for its intended function.

Inspector Fol 1 ow-up Item 50-410/84-10-13 i s closed.

12.

81066 Assessment Aids The licensee had not yet completed work on the assessment system at the time of this review.

The inspectors observed that the system does not fully cover all of the areas to be assessed, and that the licensee was reviewing the matter.

Inspector Follow-up Item 50-410/84-10-14 remains ope Access Control Personnel The isnpectors observed that the licensee had an adequate access control and badging system and that all personnel entering the Protected Area were properly searched for unauthorized material.

The search equipment was functioning properly during the review, is adequate and appropriate for its intended purpose, and conforms to the NRC-approved security plan.

Inspector Follow-up Item 50-410/84-10-15 is closed.

81072 Access Control Packa es The inspectors observed the control of packages and material entering the Protected Area.

Packages and material are examined using x-ray equipment and/or visually.

The search equipment is adequate for its intended use, was functioning properly at the time of the review, and conforms to the NRC-approved security plan.

Inspector Follow-up Item 50-410/84-10-16 is closed.

81074 Access Control Vehicles The licensee had not yet completed its review of the vehicle entry port.

Inspector Follow-up Item 50-410/84-10-17 remains open.

81078 Detection Aids Protected Area The licensee, at the request of and under the direct observation of the inspectors, performed penetration testing of the intrusion detection system.

The results of the testing were satisfactory.

Inspector Follow-up Item 50-410/84-10-18 is closed.

81080 Detection Aids Vital Areas Ongoing construction activities in the vital areas prevented the ins-pectors from conducting a complete review of vital area detection aids.

This will be reviewed during a subsequent inspection.

Inspector Fol low-up Item 50-410/84-10-19 remains open.

81084 Alarm Stations The inspectors observed that the combining of the Units 1 and 2 central alarm stations (CAS) into a single facility was complete.

Both the CAS and the secondary alarm stations (which will also be combined in the future) were determined by the inspectors to be adequate for their in-tended purpose and in accordance with the licensee's NRC-approved security pla h V

Inspector Follow-up Item 50-410/84-10-20 is closed.

19.

81088 Communications The inspectors concluded from a review of the licensee's communications system that full site communications coverage was available.

Telephones and/or paging capability were noted to be available in areas where radio communications were not possible.

Communications capabilities are in accordance with the licensee's NRC-approved security plan.

Inspector Follow-up Item 50-410/84-10-21 is closed.

20.

81601 Securit Contin enc Plan The inspectors reviewed documentation of ten contingency plan drills conducted by the licensee prior to this review.

The inspectors also noted that the licensee established a separate security contingency control/

command facility so as not to interfere with CAS operations during emer-gencies.

The inspectors reviewed the written procedures for the duties of operat-ing, maintenance, security, and management personnel relative to their response to security related events.

The inspectors determined the pro-cedures to be adequate for their intended purpose.

Inspector Follow-up Items 50-410/84-10-23 and 50-410/84-10-24 are closed.

21.

92706 Inde endent Ins ection Effort The inspectors reviewed the licensee's actions relative to the one re-maining IE Information Notice (85-28) not previously reviewed that per-tained to physical security.

Actions taken by the licensee were found to be adequate and and appropriate (see paragraph 11).

Inspector Follow-up Item 50-410/84-10-25 i s closed.

Editorial Note IE Information Notice 84-08 was erroneously listed in Region I Inspection Re-port No. 50-410/85-48, paragraph B,

as IE Information Notice 85-08.

It was closed in that report.