IR 05000369/1988019

From kanterella
Jump to navigation Jump to search
Insp Repts 50-369/88-19 & 50-370/88-19 on 880627-0701.No Violations or Deviations Noted.Major Areas Inspected:Nde Activities Re Resistance Temp Detector Sys Mods & Inservice Insp & Preservice Insp Being Accomplished During Outage
ML20151Q645
Person / Time
Site: McGuire, Mcguire  
Issue date: 07/21/1988
From: Blake J, Newsome R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML20151Q638 List:
References
50-369-88-19, 50-370-88-19, IEB-88-002, IEB-88-005, IEB-88-2, IEB-88-5, NUDOCS 8808110240
Download: ML20151Q645 (12)


Text

_ _ _ - _ _ _ _ _ _ _ -

[,GCtcug*

UNITED STATES

,

'

NUC!. EAR REGULATORY COMMISSION

  1. "\\',) d

"

REGION 11 I

101 MARIETTA STREET, N.W.

EI

- "f ATLANTA, GEORGI A 30323

$

%J

,o

+...+

Report Nos.:

50-369/88-19 and 50-370/88-19 Licensee:

Duke Power Company 422 South Church Street Charlotte, NC 28242 Docket Nos.:

50-369 and 50-370 License Nos.:

NPF-9 and NPF-17 Facility Name: McGuire 1 and 2 Inspection due eddu e 27 - July 1,1988 Inspect r.

-

w

/

L <W Newsome Date Si'gned Approved by:

'

/

/

J yFBlake, Chief Date ' Signed eferials and Processes Section Erlgineering Branch Division of Reactor Safety SUMMARY Scope:

This routine, unannounced inspection was conducted on site in the areas of Unit 2 Nondestructive Examination (NDE) activities associated with the Resistance Temperature Detector (RTD) system modifications, independent review of radiographs associated with the Upper Head Safety Injection System (UHSIS) piping deletion, and Inservice Inspection (ISI) and Preservice Inspection (PSI) being accomplished during this outage.

Also, inquiries and discussions with regard to Bulletins 88-02 and 88-05.

Results:

In the areas inspected, violations or deviations were not identified.

,

8808110240gB[O

l PDR ADOCK pg,

G l

.

_.

-

._

__

_

_

_

.

.

,

.

REPORT DETAILS 1.

Persons Contacted Licensee Employees

  • N. Atherton, Compliance Production Specialist'
  • W. Goodman, Quality Assurance (QA) Technical Support Supervisor
  • B. Hamilton, Superintendent Technical Services
  • S. LeRay, Licensing O. Mayes, Maintenance Engineer
  • R. Sharpe, Compliance Engineer
  • B.

Travis, Operations

,

T. Troutman, QA Inservice Inspection (ISI)

  • G. Underwood, QA, ISI, Operations Other licensee employees contacted during this inspection included craftsmen, engineers, mechanics, security force members, technicians, and administrative personnel.

Other Organizations Babcock and Wilcox R. Patterson, ISI Supervisor NRC Resident Inspectors j

  • R. Croteau, Resident Inspector
  • D. Nelson, Resident Inspector
  • Attended exit interview 2.

NDE of RTD System Fabricated Modifications, Unit 2 (57050) (57060) (57090)

The inspector examined documents and records as ir.dicated below to determine whether NDE was being conducted in accordance with applicable procedures, regulatory requirements, and licensee commitments.

The applicable fabrication code is the American Society of Mechanical Engineers Boiler and Pressure Vessel (ASME B&PV) Code,Section III,1983 edition. Westinghouse Electric Corporation [W) is making the modifica-tions using their personnel and working under the [W) QA program, a.

The inspector reviewed the below listed procedures for procedure approval, requirements for qualification of NDE personnel, and compilation of required records.

_

_

-

-

.

.

.

Procedure Title NDE-240 (RO)

Liquid Penetrant Examination NDE-110 (RO)

Visual Examination NDE-10 (R16)

General Radiography Procedure The inspector reviewed Liquid Penetrant (PT) Procedure NDE-240 to ascertain whether it had been reviewed and approved in accordance with the established QA procedures. The above procedure was reviewed for technical adequacy and conformance with the ASME Code Section V, Article 6, and other licensee commitments / requirements in the below listed areas:

specified method; penetrant material identification; penetrant materials analyzed for sulfur; penetrant materials analyzed for total halogens; acceptable pre-examination surface; drying time; method of penetrant application; surface temperature; solvent removal; surface drying prior to developing; type of developer; examination technique; evaluation technique; and, procedure requalification.

The inspector reviewed Visual (VT) examination Procedure NDE-110 to determine whether it contained sufficient instructions to assure that the following parameters were :pecified and controlled within the limits permitted by the applicable code, standard, or any addition

,

specification requirement: methods - direct visual, remote visual or translucent visual; application - hydrostatic testing, fabrication procedure, visual examination of welds, leak testing, etc.; how visual examination is to be performed; type of surface condition available; method or implement used for surface preparation, if any; whether direct or remote viewing is used; special illumination, instruments, or equipment to be used, if any; sequence of performing examination, when applicable; data to be tabulated, if any; acceptance criteria is specified and consistent with the applicable code section or controlling specification; and, report form

)

completion.

s The inspector reviewed Radiography (RT) Procedure NDE-10 to determine l

whether it contained sufficient information to assure that the'

i following parameters were specified and controlled within the limits permitted by the applicable code, or any additional specification requirements: type of material to be radiographed; material and weld surface condition requirements; type of radiation source, effective focal spot or effective source size; film brand or type; number of films in cassette; minimum source to film distance; type and thickness of intensifying screens and filters; quality of radio-craphs; film density and contrast for single and composite viewing; use of densitometers for assuring compliance with film density requirements; system of radiograph identification; use of location markers; methods of reducing and testing for back-scatter; selection of penetrameters including penetrameter placement; number of penetrameters; shims under penetrameters; radiographic technique for double wall viewing; and, evaluation and disposition of radiographs.

- - - =--

-

.

.

-._.

. - - - - -

.

.

'

.

.

,

.

\\

.

.

1 l

l b.

The below listed radiographs were independently interpreted by the NRC inspector to determine if radiographic quality was in accordance with the applicable procedure and Code requirements and to speci-fically verify the following:

penetrameter type, size, and placement; penetrameter sensitivity; film density and density variation; film identification;. film quality; weld coverage; and,

,

disposition of.the welds.

Weld ID Radiographic View NC2F2-8C 0-1,1-2,2-3,3-4,4-5,5-0 NC2F3-14A 0-1,1-2,2-3,3-4,4-5,5-6,6-7,7-0 NC2F4-9A 0-1,1-2,2-3,3-4,4-5,5-6,6-7,7-0 NC2F2-13A 0-1,1-2,2-3,3-4,4-5,5-6,6-7,7-0 NC2F1-13A 0-1,1-2,2-3,3-4,4-5,5-0 NC2F1-12A 0-1,1-2,2-3,3-4,4-5,5-0 c.

The inspector reviewed the calibration documentation for the below listed radiographic film interpretation equipment.

Densitometer - Serial No. 26083 d.

Records of completed nondestructive examinations were selected and reviewed to ascertain whether:.the method (s), technique, and extent of the examination complied with the applicable NDE procedure; findings were properly recorded and evaluated by qualified personnel; programmatic deviations were recorded as required; personnel, instruments, calibration blocks, and NDE materials (penetrants, couplants) were designated.

Records selected for this review are listed below.

Weld ID Method NC2F2-8A PT/VT NC2F2-19A VT NC2F1-19B PT

,

NC2F1-20B PT NC2F3-15A PT/VT NC2F3-17A PT/VT NC2F3-17B PT/VT NC2F2-18A PT/VT NC2F2-18B PT/VT NC2F2-8C RT NC2F3-14A RT NC2F4-9A RT NC2F2-13A RT i

NC2F1-13A RT NC2F1-12A RT l

i

.

.

.

.

.

.

.

.

.

.

_

.

.

.

.

.

.

e.

The inspector reviewed the below listed liquid penetrant materials certification records to ascertain if the sulfur and halogen content of the material was within acceptable content limits.

Material Batch Number Liquid Penetrant 85K050 Cleaner / Remover 87L009 Developer 86B070 f.

The inspector reviewed the qualification documentation for the below listed Westinghouse examiners in the following areas:

employer's name; person certified; activity qualified to perform; effective period ' of certification; signature of employer's designated representatives; basis used for certification; and, annual visual acuity, color vision examination and periodic recertification.

Method-Level Examiner RT PT VT MJS

--

II II GWB

--

II II MJF

--

II II

.

JES III

--

--

Within the areas examined, no violations or deviations were identified.

3.

UHSIS Piping Deletion Radiography Unit 2 (57090)

Radiography activities associated with the new welds generated by the deletion of piping in the safety injection system were reviewed as documented below. All radiography was-performed by Duke Power Company personnel.

a.

The inspector reviewed RT Procedure NDE-10 Rev. 16 "General Radiography Procedure," to determine whether it contained sufficient information to assure that the following parameters were specified-l and controlled within the limits permitted by the applicable code, or any additional spt.:ification requirement:

type of materials to be radiographed; material and weld surface condition requirements; type of radiation source; effective focal spot or effective source size; film brand or type; number of films in cassette; minimum source to film dis;ance; type and thickness of intensifying screens and filters; quality of radiographs; film density and contrast for single and composite viewing; use of densitometers for assuring compliance with film density requirements; system of radiograph identification; use of location markers; methods of reducing and testing for back-scatter; selection of penetrameters including penetrameter placement; number of penetrameters; shims under penetrameters; radiographic technique for double wall viewing; and, evaluation and disposition of radiographs.

-

-

- -

.

-

-

.

.

.

..

.

,

.

.

b.

The inspector performed an independent evaluation of the below listed finally accepted weld radiographs to determine if ' radiographic film quality.was in accordance with the' applicable procedure and Code requirements and to specifically verify the following:

penetrameter type, size, and placement; penetrameter sensitivity; film density and density variation; film identification; film quality; and weld coverage.

Veld 10 Radiographic View NI2FW23-16 0-1,1-2,2-3,3-4,4-5,5-0 NI2FW23-9 0-1,1-2,2-3,3-4,4-5,5-0 NI2FW173-1 0-1,1-2,2-3,3-4,4-5,5-0 NI2FW173-7 0-1.1-2,2-3,3-4,4-5,5-0 NI2FW173-3 0-1,1-E,2-3,3-4,4-5,5-0 NI2FW173-5 0-1,1-2,2-3,3-4,4-5,5-0 c.

The inspector reviewed the associated examination records for the above listed welds to determine compliance with procedure require-ments for examination records and to determine if the reported disposition of tha welds was consistent with the independent evaluation and in compliance with the applicable Code and specif1-cation requirements. The inspector found no discrepancies.

!

d.

A review of qualification records for three radiographic examination personnel was accomplished to determine whether the qualification records reflect the employer's name, person certified, activity qualified to perform, level of qualification, effective period of certification, basis used for ' certification, and annual, visual acuity.

e.

The inspector reviewed the weld process control sheets and the

,

detailed process control sheets for welds NI2FW173-1 and NI2FW173-5 to ascertain if the documents were complete and accurate.

l Within the areas examined, no violations or deviations were

~1 identified.

l

'

4.

Inse vice Inspection (ISI) and Preservice Inspection (PSI) Unit 2 The inspector examined documents, activities, and records as indicated below to determine whether ISI/ PSI was being conducted in accordance with applicable procedures, regulatory requirements and licensee commitments.

The applicable code for ISI/ PSI is American Society of Mechanical Engineers Boiler and Pre,sure Vessel (ASME B&PV) Code,Section XI,1980 edition with addenda through Wint ar 1980.

Duke Power Company (DPC)

nondestructive examination personnel are performing the liquid penetrant (PT) examinations while Babcock and Wilcox (B&W) personnel are performing the ultrasonic (UT) and primary eddy current (EC) examination evaluation j

for Duke Power.

Duke Power personnel are being used to collect the EC data and are performing a secondary examination data evaluation.

_

_ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _

-

.

.

.

.

The licensee has completed modifications to the RTD system and had deleted portions of the Upper Head Safety Injection System piping.

These

[

activities have resulted in new weld joints being introduced into these

'

systems which require PSI examinations.

The inspector has reviewed some of the documentation associated with the PSI of these new welds.

These reviewed are documented in the following subparagraphs.

a, Observation of Work and Work Activities (73753) (73053B)

The inspector observed work activities and reviewed certification records of equipment, materials, and NDE personnel which had been and will be utilized during the required ISI/ PSI examinations.

The observations and reviews conducted by the inspector are documented

!

'

below.

(1) The inspector reviewed the below listed liquid penetrant materials certification records to ascertain if the sulfur and halogen content of the material was within acceptable content limits.

These materials were used to perform PSI examinations.

Materials Batch Number Liquid Penetrant 85LO45 Cleaner / Remover 85M053 Developer 85K080 (2) Steam Generator Tubing Eddy Current (EC) Examination The inspector observed the Eddy Current activities indicated below.

The observations were compared with the applicable procedures and the Code in the following areas:

methods for maximum sensitive is applied; method of examination has been recorded; examination equipment has been calibrated in accordance with the applicable performance reference; required coverage of steam. generator tubes occurs during the examination; acceptance criteria is specified or referenced and is consistent with the procedure or the ASME Code; and, results are consistent with the acceptance criteria.

In process Eddy Current inspection data evaluation was observed for the following Steam Generator 0 tubes:

Row Column

67

66

65

64

63

62

61

-

_ - - _ - _ _ _ _ _

_

_ _

_

_.

..

.

-

.

.

,

.

.

Row Column (continued)

8

7

6

5

4

3

2

69

68

64

63

64

58-

67

69 (3) The inspector reviewed the qualification documentation for two DPC PT examiners in the following areas: employer's name; person certified; activity qualified to perform; ef fective period of certification; signature of employer's designated represen-

,

tative; basis used for certificaticn; and, annual visual acuity, color vision examination, and periodic recertification, b.

ISI/ PSI Data Review and Evaluation (73755) (73055)

Records of completed nondestructive examinations were selected and reviewed to ascertain whether: the methcJ(s), technique, and extent of the examination complied with the ISI plan and applicable NDE procedures; findings were properly recorded and evaluated by l

qualified personnel; programmatic deviations were recorded as required; personnel, instruments, calibration blocks, and NDE materials (penetrants, couplants) were designated. Records selected for this review are listed.

ISI UT DATA Weld No.

ISI Item No.

2NI2F-557 809.011.422

'

2NI2F-559 B09.011.423 2NI2F-563 809.011.424 2NI2F-751 B09.011.420 2NI2F-550 B09.011.421 2PZR-W3SE B05.020.003 2PZR-4ASE 805.020.004 2NI2F-57)

B09.011.426 2NI2F-57 '

B09.011.427 2N I P-19'.-1 809.011.425 2PZR-9 B02.012.002 2NI2F-2747 809.011.418 2 NIP-131-1 C05.021.362

-

-

-

.

.

. --

.

- -

- -

-

-

-*

.

,

.

.

The inspector compared current UT examination results with randomly selected previous examination results.

The results:were.in general agreement.

ISI EC Data SG-A SG-B Row Column Row Column

44

94

85

91

68

111

58

109

87-46

31

45

34

26

5

17 62-

42

68

,

SG-C SG-0 Rw Column Row Column

95

2

66

61

66

25

62

55

12

43

13

43-

11

48 I

60

34

56

11 The above EC data reviews were compared with the applicable procedures and the Code in the following areas:

the multichannei eddy current examination equipment has been identified; material permeability has been recorded; method of examination has been recorded; and, results are consistent with acceptance criteria.

By the conclusion of the NRC inspection, all EC examinations had been completed. The final examination results will be reported to the NRC in accordance with TECH SPEC requirements. The status for the steam j

generators is listed below.

I SG-A SG-B SG-C SG-U Tubes to be plugged

35

37 Previously plugged tubes 150 15Q 146 139 TOTAL 192 191 198 176

. - -..

_. _

.

.

_,

.

.

.

.

PSI PT Data Weld No.

System NI2FW-173-1 UHSIS NI2FW-173-3 UHSIS NI2FW-173-5 UHSIS NI2FW-173-7 UHSIS NC2F1-12A RTO NC2F1-13A RTO NC2F1-19A RTO NC2F1-19B RTD NC2F1-20A RTD NC2F1-20B RTD NC2F2-8A RTD NC2F2-8B-RTD NC2F2-8C RTO NC2F2-13A RTD NC2F2-18A RTD NC2F2-188

~ RTD NC2F2-19A RTD NC2F2-19B RTO NC2F3-14A RTO

,

NC2F3-15A RTD NC2F3-17A RTD NC2F3-178 RTD NC2F4-6A RTD NC2F4-9A RTO NC2F4-18A RTD NC2F4-188 RTD Within the areas inspected, no violations 'or deviations were identified 5.

IE Bulletins (92703)

a.

Bulletin 88-02, Rapidly Propagating r tigue Cracks in Steam Generator a

Tubes.

Discussions with corporate and site licensee personnel regarding the eddy current examinations, assessment of flow peaking factors for tube stability, and determination of which tubes are not effectively supported by Anti-Vibration Bars (AVB), indicated the following:

Historical Eddy Current data has been reviewed for the steam

-

generator tubing at this site. No classic denting was detected in the area of. interest for these tubes. No tube plugging will be done as a result of the review of historical data or as a

result of the current eddy current examination tube denting evaluations for Unit 2.

Additional Eddy Current examinations

'

will be conducted for Unit I during the November 1988 outage.

-

-

- -

-

_ - _ _ _ _ _ _ _ _ _ _ _ _ -

.

-

,

.

I

!

-

No tube plugging will be accomplished at this site ' due to insufficient tube stability factors as a result of flow peaking.

Evaluations, witn regard to flow peaking tube stability ratios comparable to the tube rupture at North Anna, show that the flow peaking effects in these steam generators are well below those at North Anna, according to the licensee.

-

Determination of which tubes may not be effectively suprorted by AVB's is still under consideration.

Westinghouse has. been contracted to make this determination; however, historical eddy current data was not sufficient to adequately make the determination.

Additional eddy current data was taken during this outage for Unit 2 and is being forwarded to Westinghouse for further evaluation.

A. formal report is expected from Westinghouse in the near future with regard to Unit 2.

,

l Additional eddy current data is scheduled to be acquired during

'

the Unit 1 outage in November 1988, and this data will be forwarded to Westinghouse at that time.

Discussions with licensee personnel indicated that an ongoing dialogue between Duke Power Company and the NRC, with regard to other areas of concern discussed in the bulletin, has existed since

,

March 1988.

These additional areas of concern were not addressed during this inspection, b.

Bulletin 88-05, and 88-05, Supplement 1:

Nonconforming Materials Supplied by Piping Supplies, Inc. at Folsom, New Jersey and West Jersey Manufacturing Company at Williamstown, New Jersey.

Inquiries regarding this bulletin were made by the inspector in order to confirm that actions were being taken oy the licensee that will resolve the problems identified in the bulletin. The licensee is not required to officially respond to this bulletin until mid-July 1988.

Discussions with the licensee and a review of preliminary documen-tation supplied by the licensee shows that an action plan for the response to this bulletin has been established and is currently being pursued.

Preliminary documentation indicates that to date four lots of suspect materials have been identified that contain a total of 38 items.

Of the 38 items iaentified, four from each lot have been hardness tested and three of the items are in;talled, however, the three installed items are located in non-safety related systems.

The licensee is still in the process of determining how much suspect material may be located at this s'se and plans to formally respond to the bulletin at a later date as stipulated by the bullet.i._

.

..

.

.

.

6.

Exit Interview The inspection scope and results were summarized on July 1,1988, with those persons indicated in paragraph 1.

The inspector described the areas inspected and discussed in detail the inspection results.

Although reviewed during this inspection, proprietary information is not contained in this report.

.

(