IR 05000341/1986013

From kanterella
Jump to navigation Jump to search
Partially Withheld Reactive Physical Security Insp Rept 50-341/86-13 on 860416-18 (Ref 10CFR73.21).Violation Noted: Access to Safeguards Info Not Adequately Controlled
ML20206L542
Person / Time
Site: Fermi 
Issue date: 08/12/1986
From: Creed J, Drouin B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML20206L520 List:
References
50-341-86-13, NUDOCS 8608200219
Download: ML20206L542 (2)


Text

.

.

U.S. NUCLEAR REGULATORY COMMISSION

REGION III

Report No. 50-341/86013(DRSS)

Docket No. 50-341 License No. NPF-33 Safeguards Group IV Licensee: Detroit Edison Company 6400 North Dixie Highway (

Newport, MI 48166 Facility Name:

Enrico Fermi Nuclear Power Plant, Unit 2 Inspection At:

Plant Site Inspection Conducted: April 16-18, 1986 Onsite July 14-21, 1986 in NRC Region III Office Date of Previous Physical Security Inspection: April 19 through May 30, 1986 Type of Inspection-ounced Reactive Physical Security Inspection 7/7/M Inspectors:

<u

.Fv J. T Creed, Chief Dad.e /

Safe ar Section f

sAAc 42,

-

B. Woui n Datd Physical Security Inspector Approved By:

JA=,

A f//2/74.

J. R( O' reed, Chief Date Safeguards Section Inspection Summary Inspection on April 16 through July 21, 1986 (Report No. 50-341/86013(DRSS))

Areas Inspected: The circumstances surrounding the alleged discovery of documents containing Safeguards Information in the owner controlled area on April 11, 1986 and all other associated aspects of the Physical Protection of Safeguards Information module.

Results:

It was determined that sensitive documents were not discovered in the owner controlled area as alleged nor was there an unauthorized disclosure of sensitive information. However, a violation was identified and is described below.

8608200219 860815 Enclosure contains PDR ADOCK 05000341 SAFEGUARDS INFORMATI Upon separation this PDR G

page is Decontrolled

.

f

i l

e

,

Physical Protection of Safeguards Information: Access to Safeguards t

Information was not adequately controlled.

I One open item involving the apparent intentional disregard of a licensee security procedure by a Nuclear Security Department employee was identified

'

during the inspection.

(Details: UNCLASSIFIED )

l

l l

Enclosure contains 2 Upon separation this page 15 Decontrolled

._,