Insp Repts 50-321/87-01 & 50-366/87-01 on 870120-23.No Violations or Deviations Noted.Major Areas Inspected: Licensee Action on Previous Enforcement Matters,Inservice Testing of Pumps & Valves & Inspector Followup Items
ML20211A633
Person / Time
Site: Hatch  
Issue date: 02/06/1987
From: Blake J, Menning J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML20211A593 List:
References
50-321-87-01, 50-321-87-1, 50-366-87-01, 50-366-87-1, NUDOCS 8702190205
Download: ML20211A633 (8)


Text

.

p2 8:f coq'o UNITED STATES

NUCLEAR REGULATORY COMMISSION

-['

REGION li

,

g j

101 M ARIETTA STREET, N.W.

ATLANTA, GEORGIA 30323 k...,/

Report Nos.:

50-321/87-01 and 50-366/87-01 Licensee: Georgia Power Company P. O. Box 4545 Ar.lanta, GA. 30302 Docket Nos.:

50-321 and 50-366 License Nos.:

DPR-57 and NPF-5 Facility Name: Hatch 1 and 2 Inspection Conducted: January 20-23, 1987 Inspector:

R Nt.k t')

J.

nipg D4t' Signed

,

Approved by:

x //[//

A d/s 7 2x J. J. B)'ake,' Section Chief

-

Date' Signed MatripsandProcessesSection Di is on of Reactor Safety

'

SUMMARY

.

Scope:

This routine, unannounced. inspection was conducted :in the areas of licensee action on previous enforcement matters (Unit 1), inservice testing of pumps and valves (Units 1 and 2), and inspector followup items (Units 1 and 2).

Results: No violations or deviations were identified.

.

l t

?D 05 a, o$E190fCM050hoOy AD PDk

,

t

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

.

.

REPORT DETAILS

,

,

1.

Persons Contacted Licensee Employees

  • H. Nix, Plant Manager
  • D. Read, Plant Support Manager
  • P. Fornel, Manager of Maintenance
  • A. Fraser, Acting Quality Assurance (QA) Site Manager
  • T. Powers, Engineering Manager
  • S. Tipps, Nuclear Safety and Compliance Manager
  • R. Godby, Superintendent of Maintenance Operations
  • G. Barker, Instrumentation and Control (I&C) Superintendent
  • I. Buchans, I&C Supervisor
  • T. Elton, Plant Engineering Supervisor
  • J. Lewis, Operations Supervisor
  • I. Luker, Senior QA Engineer
  • D. Vaughn, Senior QA Field Representative T. Huckaby, Inservice Inspection (ISI) Engineer Other licensee employees contacted included engineers, operators, security force members, and office personnel.

NRC Resident Inspectors

  • P. Holmes-Ray
  • G.

Nejfelt

  • Attended exit interview 2.

Exit Interview The inspection scope and findings were summarized on January 23, 1987, with those persons indicated in paragraph 1 above.

The inspector described the areas inspected and discussed in detail the inspection findings.

No dissenting comments were received from the licensee.

The following new items were identified during this inspection.

(0 pen) Inspector Followup Item 321,366/87-01-01, Review of Testing of Power Operated Valves - paragraph 5.c.

(0 pen) Inspector Followup Item 321, 366/87-01-02, Review of Test Require-ments for Dual Function Check Valves - paragraph 5.c.

The licensee did not identify as proprietary any of the materials provided to or reviewed by the inspector during this inspection.

I

_

..

_ _ _ - - _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _-- _

- - - -

l

~

.

,.

.

.-

-

..

. - _ -

-

,.

.

__.

.

_

-L

.

,

3.

Licensee Action on Previous Enforcement Matters (927028)(Unit 1)

(Closed) Violation 321/86-05-01, Failure to have a Procedure for Conducting Acid Etch Examinations on Safety-Related Components.

GPC's letter of response dated May 12, 1986, has been reviewed and determined to be acceptable by RII. The inspector held discussions with a cognizant engineer-and examined the corrective actions as stated in the letter of response.

The inspector concluded that GPC had determined the full extent. of the

!

subject noncompliance, performed the necessary survey and followup action to correct the present conditions and developed the necessary corrective actions to preclude recurrence of similar circumstances.

The corrective actions identified in the letter of response have been implemented.

4.

Unresolved Items Unresolved items were not identified during this inspection.

i 5.

Inservice Testing of Pumps and Valves (617008 and 617258)(Units 1 and 2)

The inspector reviewed procedures and records and observed testing, as described below, to determine whether applicable code, procedure, and regulatory requirements were being met.

The licensee submitted its Interval 2 In-Service Testing Program (IST) for pumps and valves for both Hatch units to the Office of Nuclear Reactor Regulation (NRR) on June 25, j

1985.

This program conforms to the ASME Boiler and Pressure Vessel Code,Section XI, 1980 Edition through the winter 1981 Addenda.

The updated IST

-

Program is applicable for the 120-month interval which began, for both

,

units, on January 1,1986.

a.

The inspector reviewed the following procedures for administration and control of the IST program:

40AC-ENG-001-OS, Rev. O, " Inservice Inspection Program"

-

,

'

-

40AC-REG-001-0S, Rev. 2, " Technical Specifications Surveillance Program"

'

42EN-INS-001-0S, Rev. 0, "ISI Pump and Valve Operability Program"

-

-

31G0-INS-001-0S, Rev. 2, "ISI Pump and Valve Operability Tests" 50AC-MNT-001-0S, Rev. 5, " Maintenance Program"

-

50AC-MNT-002-0S, Rev. 2. " Control of Measuring and Test Equipment"

-

-

The above procedures were reviewed to determine if the licensee has assigned responsibilities for the following:

j Preparation, review, and approval of IST procedures

-

-- ---

,,---.-,- -

,.w,--.w.,.,4.,,,,,,.,----,,w....e-m

,,--,--,-emm,rve..,._

, y-mm erre.w-,-r..m.,m--w3mm,.

,-w,---,

-

.

.

.

Scheduling of IST tests, both normal and increased frequency

-

Performance of testing per approved procedures

-

Performance of post-maintenance and post-modification inservice

-

tests

-

Proper certification and calibration of IST instruments Training for those personnel responsible for implementing

-

inservice testing procedures b.

The inspector reviewed the following IST periodic test procedures

-

focusing on provisions for the testing of pumps:

34SV-E21-001-IS, Rev. 4, " Core Spray Pump Operability"

-

34SV-E11-001-1S, Rev. 2, " Residual Heat Removal Pump Operability"

-

34SV-E51-002-1S, Rev.1, "RCIC Pump Operability"

-

34SV-P41-001-1S, Rev. 1, " Plant Service Water Pump Operability"

-

-

34SV-C41-001-IS, Rev, 0, " Standby Liquid Control Pump Operability Test and Relief Valve Test" The above procedures were reviewed to determine whether, except as specifically addressed by relief requests, all requirements of the applicable edition of the ASME Code,Section XI are incorporated including:

-

Recording of test results per the approved procedures

-

Evaluation of test data in accordance with specified time constraints and criteria Evaluations of imposing and removing increased frequency testing

-

requirements Evaluation and justification of changes to test acceptance

-

criteria Pump vibration test data analysis and specification of location

-

for vibration measurement

!

Requirements that pump tests be conducted at reference conditions,

-

including reference speed l

_ - - -. -

-~

.

.._ -.

--

-

. - _ _.

.

.

c.

The inspector reviewed the following IST periodic test procedures, focusing on provisions for the testing of valves:

34SV-E41-001-1S, Rev. 2, "HPCI Valve Operability"

-

34SV-T46-002-25, Rev. 0, " Standby Gas Treatment System Ventilation

-

and Valve Operability" 34SV-E11-002-1S, Rev. 2, "RHR Valve Operability"

-

34SV-C41-001-1S, Rev. 0, " Standby Liquid Control Pump Operability

-

Test and Relief Valve Test" 34SV-E21-001-15, Rev. 4, " Core Spray Pump Operability"

-

-

42SV-SUV-040-1S, Rev.1, " Check Valve ISI Internals Inspection" The above procedures were reviewed to determine whether, except as specifically addressed by relief requests, all requirements for the applicable edition of the ASME Code,Section XI are incorporated including:

Recording of test results per the approved procedures

-

Evaluation of test data in accordance with specified time

-

constraints and criteria

-

Positive testing of check valves whose safety function is to both open and close Observation of valves with remote position indicators at least

-

once very two years

-

Setting of limiting valve stroke times commensurate with the capabilities of the valve tested During this review, the inspector noted a potential deficiency in some of the licensee's procedures for stroke time testing of power operated valves.

IWV-3410 of Section XI requires, in part, that Category A and B valves be exercised at least once every three months, except as provided by the Code.

If a power operated valve exhibits an increase in stroke time of 25% or more from the previous test for valves with full-stroke times greater than 10 sec or 50% or more for valves with full-stroke times less than or equal to 10 sec, the test frequency must be increased.

Additionally, if a valve exceeds its limiting value of full-stroke time during such testing, corrective action must be initiated immediately.

If the condition is not, or cannot be, corrected within 24 hr, the valve must be declared inoperative.

The

_ _.

_

_

_ _..

. _., _ _

_

_ _._

_.

.

.

inspector noted that some data sheets used for quarterly testing of power operated valves do not provide the limiting values of stroke time or for a determination that such times have not been exceeded.

The inspector found that in such cases limiting values of stroke time are provided on the data sheets used for monthly testing of power operated valves.

If monthly testing is performed subsequent to the quarterly testing, determination of the inoperative condition of a valve could be

'

delayed.

It appears that administrative controls should be established to require that quarterly and monthly testing be accomplished together or the involved data sheets for quarterly testing should be modified to provide the limiting values of stroke time. A licensee representative agreed to investigate the inspector's concern and take any appropriate actions.

Pending completion of the licensee's actions, this matter is identified as Inspector Followup Item 321, 366/87-01-01, Review of Testing of Power Operated Valves.

The inspector also noted during this review that procedures are not in place to positively test certain Category C check valves that are normally closed and have safety functions in both the open and closed positions.

More specifically, the licensee's current program requires the standby liquid control pump discharge check valves (C41-F033A and B) to be exercised to the open position on a quarterly basis.

The related periodic test procedure (34SV-C41-001-IS, Rev. 0, " Standby Liquid Control Pump Operability Test and Relief Valve Test") does not provide for closure testing after opening.

IWV-3522(b) of Section XI requires that normally closed check valves be periodically exercised to the open position, but does not specifically require testing to the closed position for those valves that also have a safety function in the closed position.

Despite the ambiguity of the current Section XI requirements, industry experience has shown that exercising to the open position cannot be relied upon alone to demonstrate the overall operability of such dual function check valves.

Discussions with a licensee representative revealed that GPC was aware of the need to test dual function check valves for closure and is currently considering how best to accomplish this testing.

Pending completion of the licensee's review and followup by the inspector, this matter is identified as Inspector Followup Item 321, 366/87-01-02, Review of Test Requirements for Dual Function Check Valves.

d.

The test records listed below were reviewed for the 12-month period

'

commencing July, 1985, to determine whether inservice testing test data were evaluated in accordance with the requirements of Subsections IWP and IWV of Section XI, and whether appropriate actions were taken, i.e.,

increased frequency of testing, repairs, declaration of j

component / system as inoperable, etc.

l

!

i

,

.

.

>

Procedures Unit 34SV-T46-002-2S

"'.andby Las Treatment System

Ventilation and Vz e Operability" 34SV-E21-002-1S

" Core Spray Valve Operability"

34SV-C41-001-1S

" Standby Liquid Control Pump

Operability Test and Relief Valve Test" 34SV-E41-001-1S

"HPCI Valve Operability"

e.

The Maintenance Work Order (MW0) packages listed below were reviewed to determine whether required inservice testing of pumps and valves was performed after maintenance or modification, and whether test data were evaluated to determine component operability.

MWO Numbers Involved Component Unit MWO2-85-4276 Standby Gas Treatment

Valve T46-F0018 MW01-85-7210 HPCI Valve E41-F003

MW01-85-3595 Standby Liquid Control

Valve C41-F029B MW01-86-1507 Standby Liquid Control

Valve C41-F029B MW01-85-05191 Core Spray Pump E21-C001B

MW01-86-1302 Core Spray Pump E21-C001A

MW01-86-00572 RHR Pump E11-C002A

MW01-86-01465 RHR Pump E11-C002C

MWO2-86-02271 RCIC Pump E51-C001

f.

The inspector observed RHR system quarterly valve operability testing in Unit 1 to determine the adequacy and completeness of the test procedure being used. The observed testing was performed in accordance with 34SV-E11-002-1S, Rev. 2, "RHR Valve Operability."

Within the areas inspected, no violations or deviations were identified.

.-

-.-.

. - - -

-. -. - - -

.

.

.

.

.-

,

6.

Inspector Followup Items (92701B)(Units 1 and 2)

(Closed) Inspector Followup Item 321, 366/86-32-01, Review of Approved Procedure for Monitoring Extraction Steam Piping.

The inspector reviewed the licensee's recently issued procedure 421T-N36-001-0N, Rev. O, "Inspec-tion of Plant Steam Piping for Erosion / Corrosion." The inspector noted that this procedure applies to both units, and provides for the ultrasonic monitoring of the auxiliary drains and vent systems and condensate and feedwater systems in addition to the extraction steam systems.

The procedure specifies that the Engineering Department will select specific inspection points and related monitoring frequencies, and provides flexi-bility for adding follow-on inspection points based on operating experience.

Review of this item is closed.

.