U.S. NUCLEAR REGULATORY COMMISSION

,

REGION III

Report No. 50-255/930ll(DRSS)

<

Docket No. 50-255 License No. DPR-20 Licensee: Consumers Power Company 27780 Blue Star Memorial Highway Covert, MI 49043 Facility Name:

Palisades Nuclear Generating Plant

.

Inspection Dates: May 10-14 and 17-18, 1993 Type of Inspection: Announced, Routine Physical Security Inspection

,

Date of Previous Physical Security Inspection: Between October 5-13, 1992 Inspector:

%

oAA,

6h/O Terry J. Madeda ~

Dat4 '

Physidl Security Inspector

,

O /t) /ifemad.,L

/m 6 /y/y 3 Reviewed By:

Cdames R. Creed, Chief a

/

Date

~

'

Safeguards Section Inspection Summarv Insoection on May 10-14 and 17-18. 1993 (Report No. 50-255/930ll(DRSS))

Areas Inspected: Routine, announced physical security inspection involving Protected and Vital Area Access Control of Personnel, Packages and Vehicles; Alarm Stations and Communications; Power Supply; Testing, Maintenance and Compensatory Measures; Security Training and Qualification; Followup to Previous Inspection Findings; and Inspection Activities Relating to the Licensee's Independent Spent Fuel Storage Installation.

Results: One violation involving observed weak search techniques and multiple

,

drill failures of hand-carried items was identified.

Initial corrective

'

action was implemented by the licensee. One non-cited violation involving the failure to stamp and control some protected information was identified.

,

Corrective action to prevent recurrence was implemented. One inspector

'

followup item involving reduced reliability of some security equipment was identified.

Licensee actions to resolve a previously identified finding regarding the effectiveness of agility testing was not fully effective.

Encldsure Contatnc :

9306140082 930604 IT PDR ADOCK 05000255

~2 Upon Separation This

,

G PDR Page is Decontrel* d

,

a

o

.

~

.

.

Licensee overall performance in implementing the security program was good.

Weaknesses were identified in one portion of protected area access control activities. These weaknesses involved poor implementation and less than effective management overview of search activities of hand-carried items. A weakness was also identified in management's effort to resolve in a timely manner a reliability problem with some intrusion alarm detection devices.

Positive performance was noted regarding the effectiveness and implementation of alarm station activities, resolving reactive and preventative maintenance issues, and conducting security training activities regarding tactical drills.

Positive licensee performance was noted in planning and implementation of security activities relating to the independent spent fuel storage installation (ISFSI). During our review of this activity, the inspector identified one minor weakness involving the height of a security barrier in one location.

The licensee implemented action to correct the problem.

'

Specific inspection results showed, except for the issues noted above, that the licensee was implementing a security program that addressed security plan commitments and that management activities supported the security program in-an appropriate manner.

l

.

.

,

i

!

l l

cent tos

SAFBCUMt!E l' i'EXATION

'

Doo tro i

---r

-

-. - - - - - - - - -

--

-

-