MONTHYEARIR 05000029/19990021999-08-0404 August 1999 Insp Rept 50-029/99-02 on 990411-0714.One Violation Noted & Being Treated as Ncv.Major Areas Inspected:Safe Operation of Sf Pool,Radiological Controls,Organization & Mgt Controls & Auditing & C/As for Decommissioning Activities IR 05000029/19990011999-05-0505 May 1999 Insp Rept 50-029/99-01 on 990101-0411.No Violations Noted. Major Areas Inspected:Cold Weather Preparations for Spent Fuel Pool,Radiological Controls & self-assessment & Auditing & Corrective Actions for Decommissioning Activities IR 05000029/19980031998-10-0101 October 1998 Insp Rept 50-029/98-03 on 980601-0731.No Violations Noted. Major Areas Inspected:Decommissioning Activities,Including Mods to Spent Fuel Pool Bldg & Radiological Controls IR 05000029/19980011998-06-24024 June 1998 Insp Repts 50-029/98-01 & 50-029/98-02 on 980101-0331.No Violations Noted.Major Areas Inspected:Mod to SFP Bldg, Radiological Controls & Decommissioning Activities IR 05000029/19970021997-09-23023 September 1997 Insp Rept 50-029/97-02 on 970401-0814.No Violations Noted. Major Areas Inspected:Licensee Activities Re Decommissioning IR 05000029/19970011997-05-16016 May 1997 Insp Rept 50-029/97-01 on 970301-31.No Violations Noted. Major Areas Inspected:Facility Operations IR 05000029/19960041997-01-24024 January 1997 Insp Rept 50-029/96-04 on 961119-21.No Violations Noted. Major Areas Inspected:Insp Verified by Observation, Documentation Review &/Or Discussions W/Responsible or Involved Plant Staff IR 05000029/19960031996-10-16016 October 1996 Insp Rept 50-029/96-03 on 960827-29.No Violations Noted. Major Areas Inspected:Operations,Rp Program,Including Operations,Staffing,Mgt & Licensee Experience in Identifying & Correcting Weaknesses Re Control of Radioactive Matls IR 05000029/19930071993-12-28028 December 1993 Insp Rept 50-029/93-07 on 930826-1118.Violation Noted. Major Areas Inspected:Posting of Radiological Areas & Other Controls,Organization & Staffing,Exposure ALARA Program & Radiological Info Available to Workers IR 05000029/19930081993-11-0909 November 1993 Insp Rept 50-029/93-08 on 931018-19.No Violations Noted. Major Areas Inspected:Mgt Support & Audits Protected Area Barriers,Detection & Assessment Aids Protected Area Access Control of Personnel,Alarm Stations & Communications IR 05000029/19930051993-08-18018 August 1993 Insp Rept 50-029/93-05 on 930510-0731.No Violations Noted. Major Areas Inspected:Operations,Maint Engineering & Plant Support,Including Radiological Controls,Security,Fire Protection & Housekeeping & Administration IR 05000029/19930041993-06-30030 June 1993 Insp Rept 50-029/93-04 on 930308-0610.No Violations Noted. Major Areas Inspected:Posting of Radiological Areas & Other Controls Observed During Facility Tours,Organization & Staffing IR 05000029/19930021993-03-30030 March 1993 Insp Rept 50-029/93-02 on 930202-0320.No Violations Noted. Major Areas Inspected:Plant Operations,Radiological Controls,Emergency Preparedness & Quality Verification IR 05000029/19930031993-03-26026 March 1993 Insp Rept 50-029/93-03 on 930308-11.No Violations Noted. Major Areas Inspected:Mgt Support & Audits,Protected Area Barriers,Detection & Assessment Aids,Alarm Stations & Communications,Training & Qualifications & Security Locks IR 05000029/19930011993-03-0808 March 1993 Safety Insp Rept 50-029/93-01 on 930125-28.Violations Noted. Major Areas Inspected:Review of Various Licensee Programs, Procedures,Repts,Fire Protection,Plant Mods,Security, Emergency Preparedness & Housekeeping IR 05000029/19920111993-02-0505 February 1993 Insp Rept 50-029/92-11 on 921114-930201.No Violations Noted. Major Areas Inspected:Plant Operations,Radiological Control, Security,Engineering & Technical Support & Safety Assessment & Quality Verification IR 05000029/19920101992-11-23023 November 1992 Insp Rept 50-029/92-10 on 921104-06.One Open Items Noted. Major Areas Inspected:Contamination Monitoring of Guardhouse,Postings & Other Controls,Radiological Control of Work in Progress & Organization & Staffing ML20127F1051992-11-23023 November 1992 Corrected Cover Page for Insp Rept 50-029/92-10 on 921104-06.No Radiological Safety Concerns or Violations Noted.Major Areas Inspected:Contamination Monitoring at Guardhouse,Postings & Other Controls Observed During Tours IR 05000029/19910041991-04-23023 April 1991 Safety Insp Rept 50-029/91-04 on 910220-0415.No Violations or Deviations Noted.Major Areas Inspected:Plant Operations, Radiological Controls,Maint & Surveillance,Security, Engineering & Technical Support,Safety Assessment & Quality IR 05000029/19910011991-02-26026 February 1991 Insp Rept 50-029/91-01 on 910103-0219.No Violations Noted. Major Areas Inspected:Daytime & Backshifts of Plant Operation,Radiological Controls,Maint & Surveillance Engineering & Technical Support & Security IR 05000029/19910021991-02-22022 February 1991 Insp Rept 50-029/91-02 on 910204-08.No Violations Noted. Major Areas Inspected:Radiological Controls Program, Including & Staffing,External Exposure Controls,Internal Exposure Controls,Audits & Appraisals & ALARA IR 05000029/19900251991-01-23023 January 1991 Insp Rept 50-029/90-25 on 901114-910102.No Violations Noted. Major Areas Inspected:Plant Operations,Radiological Control, Maint & Surveillance,Security,Engineering & Technical Support,Safety Assessment & Quality Verification IR 05000029/19900231990-12-0505 December 1990 Insp Rept 50-029/90-23 on 901105-09.No Violations Noted. Major Areas Inspected:Liquid & Gaseous Radioactive Effluent Controls & Radiological Environ Monitoring Programs ML20062H0801990-11-19019 November 1990 Insp Rept 50-029/90-21 on 901015-19.Noncited Violation Noted.Areas Inspected:Response to Bulletin 79-14 Re Seismic Analysis of as-built safety-related Piping Sys IR 05000029/19900811990-09-28028 September 1990 Insp Rept 50-029/90-81 on 900709-20 & 0806-10.Weaknesses & Unresolved Item Noted.Major Areas Inspected:Maint Program IR 05000029/19900121990-09-24024 September 1990 Insp Rept 50-029/90-12 on 900619-0820.Violations Noted. Major Areas Inspected:Plant Operations,Radiological Controls,Maint & Surveillance,Security,Engineering/Technical Support,Safety Assessment/Quality Verification & Repts ML20058D3651990-09-14014 September 1990 Insp Rept 50-029/90-17 on 900730-0803.No Violations Noted. Major Areas Inspected:Audit of Licensee Action in Response to Recommendation Described in Generic Ltr 88-17 ML20059K7171990-09-0707 September 1990 Insp Rept 50-029/90-14 on 900802-27.Violations Noted Re Failure to Demonstrate Emergency Diesel Generators Operability at Required Capacity Under Design Basis Conditions.Major Areas Inspected:Emergency Diesel Generator IR 05000029/19900131990-08-0303 August 1990 Insp Rept 50-029/90-13 on 900709-13.One Noncited Violation Noted.Major Areas Inspected:Implementation of Radiation Protection Program During Current Refueling Outage & Review of Training & Qualification of Contractor Technicians IR 05000029/19900111990-08-0101 August 1990 Insp Rept 50-029/90-11 on 900619-22.No Violations or Deviations Noted.Major Areas Inspected:Safety Injection Tank Design & Replacement Procedures Together W/Walkdown of Safety Injection Sys Pumps,Valves & Piping IR 05000029/19900091990-07-16016 July 1990 Insp Rept 50-029/90-09 on 900515-0618.No Violations Noted. Major Areas Inspected:Operational Safety,Plant Operations, Radiological Controls,Maint & Surveillance,Emergency Preparedness,Security & Engineering/Technical Support IR 05000029/19900101990-06-14014 June 1990 Partially Withheld Insp Rept 50-029/90-10 on 900524 (Ref 10CFR73.21).Violations Noted.Major Areas Inspected:Licensee Security Event & Access control-vehicle IR 05000029/19900071990-06-12012 June 1990 Insp Rept 50-029/90-07 on 900403-0514.Violation & Unresolved Items Noted.Major Areas Inspected:Operational Safety,Plant Operations,Radiological Controls,Security, Maint/Surveillance & Engineering & Technical Support IR 05000029/19900081990-05-18018 May 1990 Partially Withheld Physical Security Insp Rept 50-029/90-08 on 900416-20 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Mgt Support,Security Program Plans & Audits, Protected & Vital Area Physical Barriers & Access Controls IR 05000029/19900041990-04-30030 April 1990 Insp Rept 50-029/90-04 on 900213-0402.Two Noncited Violations Noted.Major Areas Inspected:Operational Safety, Security,Plant Operations,Maint & Surveillance,Engineering Support & Radiological Controls IR 05000029/19900021990-03-12012 March 1990 Insp Rept 50-029/90-02 on 900205-09.Deviation Noted.Major Areas inspected:post-accident Monitoring Instrumentation Per Reg Guide 1.97 IR 05000029/19900011990-03-0606 March 1990 Insp Rept 50-029/90-01 on 900103-0212.Unresolved Items Noted Re 10CFR21 Rept on Safety Class 2 U-tube HX & fitness-for- Duty Program.Major Areas Inspected:Operational Safety, Security,Plant Operations,Maint/Surveillance & LERs ML20012B3841990-03-0101 March 1990 Insp Rept 50-029/90-03 on 900205-09.No Violations Noted. Major Areas Inspected:Util Activities in Response to 900110 Leak Discovered in Safety Injection Tank IR 05000029/19900051990-02-16016 February 1990 Physical Security Insp Rept 50-029/90-05 on 900207-09.No Violations Noted.Major Areas Inspected:Implementation of Safeguards Info & Personnel Access Control Programs at Corporate Ofc IR 05000029/19890801990-02-15015 February 1990 Insp Rept 50-029/89-80 on 891106-14.No Violations Noted. Major Areas Inspected:Plant Emergency Operating Procedures IR 05000029/19890201990-01-26026 January 1990 Insp Rept 50-029/89-20 on 891107-900102.Violations Noted. Major Areas Inspected:Operational Safety,Security,Plant Operations,Maint & Surveillance,Engineering Support & Actions on Previous Insp Findings IR 05000029/19890181989-12-21021 December 1989 Insp Rept 50-029/89-18 on 891010-13.No Violations or Deviations Noted.Major Areas Inspected:Implementation & Effectiveness of Licensed Operator Training Program IR 05000029/19890211989-12-21021 December 1989 Insp Rept 50-029/89-21 on 891127-29.No Violations or Deviations Noted.Major Areas Inspected:Licensee Annual Emergency Preparedness Exercise on 891128.Inspector Followup Item 50-029/88-08-01 Upgraded to Unresolved Item IR 05000029/19890171989-12-0505 December 1989 Insp Rept 50-029/89-17 on 890927-1106.No Violations Noted. Major Areas Inspected:Actions on Previous Insp Findings, Operational Safety,Security,Plant Operations,Maint & Surveillance,Engineering Support & LERs IR 05000029/19890191989-11-29029 November 1989 Insp Rept 50-029/89-19 on 891106-09.Noncited Violation Noted.Major Areas Inspected:Radiation Protection Program, Including Audits & Appraisals,Training,External Exposure Controls & Internal Exposure Controls & ALARA IR 05000029/19890111989-08-28028 August 1989 Insp Rept 50-029/89-11 on 890626-0731.Unresolved Items Noted Re Plant Operations Review Committee Actions to Address Task Force Investigation Results of 890725 Loss of Emergency Bus.Areas Investigated:Security & LERs IR 05000029/19890131989-08-23023 August 1989 Physical Security Insp Rept 50-029/89-13 on 890724-28.No Violations Noted.Major Areas Inspected:Action on Findings of NRC Regulatory Effectiveness Review,Mgt Support,Security Program Plan,Audits & Protected & Vital Area Physical IR 05000029/19890151989-08-15015 August 1989 Emergency Preparedness Insp Rept 50-029/89-15 on 890731-0803.No Violations Noted.Major Areas Inspected: Changes to Emergency Preparedness Program & Facilities, Equipment,Instrumentation & Supplies ML20246Q0301989-08-10010 August 1989 Insp Repts 50-029/89-14 & 50-271/89-10 on 890717-21.No Violations or Deviations Noted.Major Areas Inspected: Corporate Engineering & Offsite Support for Plants & Implementation of Mods IR 05000029/19890121989-08-0101 August 1989 Insp Rept 50-029/89-12 on 890710-14.No Violations or Deviations Noted.Major Areas Inspected:Solid Radwaste Sys, Transportation & Liquid & Gaseous Effluents Programs, Including:Mgt Controls,Audits,Qa & Program Implementation 1999-08-04
[Table view] Category:NRC-GENERATED
MONTHYEARIR 05000029/19990021999-08-0404 August 1999 Insp Rept 50-029/99-02 on 990411-0714.One Violation Noted & Being Treated as Ncv.Major Areas Inspected:Safe Operation of Sf Pool,Radiological Controls,Organization & Mgt Controls & Auditing & C/As for Decommissioning Activities IR 05000029/19990011999-05-0505 May 1999 Insp Rept 50-029/99-01 on 990101-0411.No Violations Noted. Major Areas Inspected:Cold Weather Preparations for Spent Fuel Pool,Radiological Controls & self-assessment & Auditing & Corrective Actions for Decommissioning Activities IR 05000029/19980031998-10-0101 October 1998 Insp Rept 50-029/98-03 on 980601-0731.No Violations Noted. Major Areas Inspected:Decommissioning Activities,Including Mods to Spent Fuel Pool Bldg & Radiological Controls IR 05000029/19980011998-06-24024 June 1998 Insp Repts 50-029/98-01 & 50-029/98-02 on 980101-0331.No Violations Noted.Major Areas Inspected:Mod to SFP Bldg, Radiological Controls & Decommissioning Activities IR 05000029/19970021997-09-23023 September 1997 Insp Rept 50-029/97-02 on 970401-0814.No Violations Noted. Major Areas Inspected:Licensee Activities Re Decommissioning IR 05000029/19970011997-05-16016 May 1997 Insp Rept 50-029/97-01 on 970301-31.No Violations Noted. Major Areas Inspected:Facility Operations IR 05000029/19960041997-01-24024 January 1997 Insp Rept 50-029/96-04 on 961119-21.No Violations Noted. Major Areas Inspected:Insp Verified by Observation, Documentation Review &/Or Discussions W/Responsible or Involved Plant Staff IR 05000029/19960031996-10-16016 October 1996 Insp Rept 50-029/96-03 on 960827-29.No Violations Noted. Major Areas Inspected:Operations,Rp Program,Including Operations,Staffing,Mgt & Licensee Experience in Identifying & Correcting Weaknesses Re Control of Radioactive Matls IR 05000029/19930071993-12-28028 December 1993 Insp Rept 50-029/93-07 on 930826-1118.Violation Noted. Major Areas Inspected:Posting of Radiological Areas & Other Controls,Organization & Staffing,Exposure ALARA Program & Radiological Info Available to Workers IR 05000029/19930081993-11-0909 November 1993 Insp Rept 50-029/93-08 on 931018-19.No Violations Noted. Major Areas Inspected:Mgt Support & Audits Protected Area Barriers,Detection & Assessment Aids Protected Area Access Control of Personnel,Alarm Stations & Communications IR 05000029/19930051993-08-18018 August 1993 Insp Rept 50-029/93-05 on 930510-0731.No Violations Noted. Major Areas Inspected:Operations,Maint Engineering & Plant Support,Including Radiological Controls,Security,Fire Protection & Housekeeping & Administration IR 05000029/19930041993-06-30030 June 1993 Insp Rept 50-029/93-04 on 930308-0610.No Violations Noted. Major Areas Inspected:Posting of Radiological Areas & Other Controls Observed During Facility Tours,Organization & Staffing IR 05000029/19930021993-03-30030 March 1993 Insp Rept 50-029/93-02 on 930202-0320.No Violations Noted. Major Areas Inspected:Plant Operations,Radiological Controls,Emergency Preparedness & Quality Verification IR 05000029/19930031993-03-26026 March 1993 Insp Rept 50-029/93-03 on 930308-11.No Violations Noted. Major Areas Inspected:Mgt Support & Audits,Protected Area Barriers,Detection & Assessment Aids,Alarm Stations & Communications,Training & Qualifications & Security Locks IR 05000029/19930011993-03-0808 March 1993 Safety Insp Rept 50-029/93-01 on 930125-28.Violations Noted. Major Areas Inspected:Review of Various Licensee Programs, Procedures,Repts,Fire Protection,Plant Mods,Security, Emergency Preparedness & Housekeeping IR 05000029/19920111993-02-0505 February 1993 Insp Rept 50-029/92-11 on 921114-930201.No Violations Noted. Major Areas Inspected:Plant Operations,Radiological Control, Security,Engineering & Technical Support & Safety Assessment & Quality Verification IR 05000029/19920101992-11-23023 November 1992 Insp Rept 50-029/92-10 on 921104-06.One Open Items Noted. Major Areas Inspected:Contamination Monitoring of Guardhouse,Postings & Other Controls,Radiological Control of Work in Progress & Organization & Staffing ML20127F1051992-11-23023 November 1992 Corrected Cover Page for Insp Rept 50-029/92-10 on 921104-06.No Radiological Safety Concerns or Violations Noted.Major Areas Inspected:Contamination Monitoring at Guardhouse,Postings & Other Controls Observed During Tours IR 05000029/19910041991-04-23023 April 1991 Safety Insp Rept 50-029/91-04 on 910220-0415.No Violations or Deviations Noted.Major Areas Inspected:Plant Operations, Radiological Controls,Maint & Surveillance,Security, Engineering & Technical Support,Safety Assessment & Quality IR 05000029/19910011991-02-26026 February 1991 Insp Rept 50-029/91-01 on 910103-0219.No Violations Noted. Major Areas Inspected:Daytime & Backshifts of Plant Operation,Radiological Controls,Maint & Surveillance Engineering & Technical Support & Security IR 05000029/19910021991-02-22022 February 1991 Insp Rept 50-029/91-02 on 910204-08.No Violations Noted. Major Areas Inspected:Radiological Controls Program, Including & Staffing,External Exposure Controls,Internal Exposure Controls,Audits & Appraisals & ALARA IR 05000029/19900251991-01-23023 January 1991 Insp Rept 50-029/90-25 on 901114-910102.No Violations Noted. Major Areas Inspected:Plant Operations,Radiological Control, Maint & Surveillance,Security,Engineering & Technical Support,Safety Assessment & Quality Verification IR 05000029/19900231990-12-0505 December 1990 Insp Rept 50-029/90-23 on 901105-09.No Violations Noted. Major Areas Inspected:Liquid & Gaseous Radioactive Effluent Controls & Radiological Environ Monitoring Programs ML20062H0801990-11-19019 November 1990 Insp Rept 50-029/90-21 on 901015-19.Noncited Violation Noted.Areas Inspected:Response to Bulletin 79-14 Re Seismic Analysis of as-built safety-related Piping Sys IR 05000029/19900811990-09-28028 September 1990 Insp Rept 50-029/90-81 on 900709-20 & 0806-10.Weaknesses & Unresolved Item Noted.Major Areas Inspected:Maint Program IR 05000029/19900121990-09-24024 September 1990 Insp Rept 50-029/90-12 on 900619-0820.Violations Noted. Major Areas Inspected:Plant Operations,Radiological Controls,Maint & Surveillance,Security,Engineering/Technical Support,Safety Assessment/Quality Verification & Repts ML20058D3651990-09-14014 September 1990 Insp Rept 50-029/90-17 on 900730-0803.No Violations Noted. Major Areas Inspected:Audit of Licensee Action in Response to Recommendation Described in Generic Ltr 88-17 ML20059K7171990-09-0707 September 1990 Insp Rept 50-029/90-14 on 900802-27.Violations Noted Re Failure to Demonstrate Emergency Diesel Generators Operability at Required Capacity Under Design Basis Conditions.Major Areas Inspected:Emergency Diesel Generator IR 05000029/19900131990-08-0303 August 1990 Insp Rept 50-029/90-13 on 900709-13.One Noncited Violation Noted.Major Areas Inspected:Implementation of Radiation Protection Program During Current Refueling Outage & Review of Training & Qualification of Contractor Technicians IR 05000029/19900111990-08-0101 August 1990 Insp Rept 50-029/90-11 on 900619-22.No Violations or Deviations Noted.Major Areas Inspected:Safety Injection Tank Design & Replacement Procedures Together W/Walkdown of Safety Injection Sys Pumps,Valves & Piping IR 05000029/19900091990-07-16016 July 1990 Insp Rept 50-029/90-09 on 900515-0618.No Violations Noted. Major Areas Inspected:Operational Safety,Plant Operations, Radiological Controls,Maint & Surveillance,Emergency Preparedness,Security & Engineering/Technical Support IR 05000029/19900101990-06-14014 June 1990 Partially Withheld Insp Rept 50-029/90-10 on 900524 (Ref 10CFR73.21).Violations Noted.Major Areas Inspected:Licensee Security Event & Access control-vehicle IR 05000029/19900071990-06-12012 June 1990 Insp Rept 50-029/90-07 on 900403-0514.Violation & Unresolved Items Noted.Major Areas Inspected:Operational Safety,Plant Operations,Radiological Controls,Security, Maint/Surveillance & Engineering & Technical Support IR 05000029/19900081990-05-18018 May 1990 Partially Withheld Physical Security Insp Rept 50-029/90-08 on 900416-20 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Mgt Support,Security Program Plans & Audits, Protected & Vital Area Physical Barriers & Access Controls IR 05000029/19900041990-04-30030 April 1990 Insp Rept 50-029/90-04 on 900213-0402.Two Noncited Violations Noted.Major Areas Inspected:Operational Safety, Security,Plant Operations,Maint & Surveillance,Engineering Support & Radiological Controls IR 05000029/19900021990-03-12012 March 1990 Insp Rept 50-029/90-02 on 900205-09.Deviation Noted.Major Areas inspected:post-accident Monitoring Instrumentation Per Reg Guide 1.97 IR 05000029/19900011990-03-0606 March 1990 Insp Rept 50-029/90-01 on 900103-0212.Unresolved Items Noted Re 10CFR21 Rept on Safety Class 2 U-tube HX & fitness-for- Duty Program.Major Areas Inspected:Operational Safety, Security,Plant Operations,Maint/Surveillance & LERs ML20012B3841990-03-0101 March 1990 Insp Rept 50-029/90-03 on 900205-09.No Violations Noted. Major Areas Inspected:Util Activities in Response to 900110 Leak Discovered in Safety Injection Tank IR 05000029/19900051990-02-16016 February 1990 Physical Security Insp Rept 50-029/90-05 on 900207-09.No Violations Noted.Major Areas Inspected:Implementation of Safeguards Info & Personnel Access Control Programs at Corporate Ofc IR 05000029/19890801990-02-15015 February 1990 Insp Rept 50-029/89-80 on 891106-14.No Violations Noted. Major Areas Inspected:Plant Emergency Operating Procedures IR 05000029/19890201990-01-26026 January 1990 Insp Rept 50-029/89-20 on 891107-900102.Violations Noted. Major Areas Inspected:Operational Safety,Security,Plant Operations,Maint & Surveillance,Engineering Support & Actions on Previous Insp Findings IR 05000029/19890181989-12-21021 December 1989 Insp Rept 50-029/89-18 on 891010-13.No Violations or Deviations Noted.Major Areas Inspected:Implementation & Effectiveness of Licensed Operator Training Program IR 05000029/19890211989-12-21021 December 1989 Insp Rept 50-029/89-21 on 891127-29.No Violations or Deviations Noted.Major Areas Inspected:Licensee Annual Emergency Preparedness Exercise on 891128.Inspector Followup Item 50-029/88-08-01 Upgraded to Unresolved Item IR 05000029/19890171989-12-0505 December 1989 Insp Rept 50-029/89-17 on 890927-1106.No Violations Noted. Major Areas Inspected:Actions on Previous Insp Findings, Operational Safety,Security,Plant Operations,Maint & Surveillance,Engineering Support & LERs IR 05000029/19890191989-11-29029 November 1989 Insp Rept 50-029/89-19 on 891106-09.Noncited Violation Noted.Major Areas Inspected:Radiation Protection Program, Including Audits & Appraisals,Training,External Exposure Controls & Internal Exposure Controls & ALARA IR 05000029/19890111989-08-28028 August 1989 Insp Rept 50-029/89-11 on 890626-0731.Unresolved Items Noted Re Plant Operations Review Committee Actions to Address Task Force Investigation Results of 890725 Loss of Emergency Bus.Areas Investigated:Security & LERs IR 05000029/19890131989-08-23023 August 1989 Physical Security Insp Rept 50-029/89-13 on 890724-28.No Violations Noted.Major Areas Inspected:Action on Findings of NRC Regulatory Effectiveness Review,Mgt Support,Security Program Plan,Audits & Protected & Vital Area Physical IR 05000029/19890151989-08-15015 August 1989 Emergency Preparedness Insp Rept 50-029/89-15 on 890731-0803.No Violations Noted.Major Areas Inspected: Changes to Emergency Preparedness Program & Facilities, Equipment,Instrumentation & Supplies ML20246Q0301989-08-10010 August 1989 Insp Repts 50-029/89-14 & 50-271/89-10 on 890717-21.No Violations or Deviations Noted.Major Areas Inspected: Corporate Engineering & Offsite Support for Plants & Implementation of Mods IR 05000029/19890121989-08-0101 August 1989 Insp Rept 50-029/89-12 on 890710-14.No Violations or Deviations Noted.Major Areas Inspected:Solid Radwaste Sys, Transportation & Liquid & Gaseous Effluents Programs, Including:Mgt Controls,Audits,Qa & Program Implementation 1999-08-04
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARIR 05000029/19990021999-08-0404 August 1999 Insp Rept 50-029/99-02 on 990411-0714.One Violation Noted & Being Treated as Ncv.Major Areas Inspected:Safe Operation of Sf Pool,Radiological Controls,Organization & Mgt Controls & Auditing & C/As for Decommissioning Activities IR 05000029/19990011999-05-0505 May 1999 Insp Rept 50-029/99-01 on 990101-0411.No Violations Noted. Major Areas Inspected:Cold Weather Preparations for Spent Fuel Pool,Radiological Controls & self-assessment & Auditing & Corrective Actions for Decommissioning Activities IR 05000029/19980031998-10-0101 October 1998 Insp Rept 50-029/98-03 on 980601-0731.No Violations Noted. Major Areas Inspected:Decommissioning Activities,Including Mods to Spent Fuel Pool Bldg & Radiological Controls IR 05000029/19980011998-06-24024 June 1998 Insp Repts 50-029/98-01 & 50-029/98-02 on 980101-0331.No Violations Noted.Major Areas Inspected:Mod to SFP Bldg, Radiological Controls & Decommissioning Activities IR 05000029/19970021997-09-23023 September 1997 Insp Rept 50-029/97-02 on 970401-0814.No Violations Noted. Major Areas Inspected:Licensee Activities Re Decommissioning IR 05000029/19970011997-05-16016 May 1997 Insp Rept 50-029/97-01 on 970301-31.No Violations Noted. Major Areas Inspected:Facility Operations PNO-I-97-026, on 970427,Yankee Atomic Electric Will Begin Shipment of Reactor Vessel for Disposal.First Phase of Shipment Will Involve Heavy Haul Truck from Rowe,Ma Site to Railway Approx Six Miles Away Near Hoosac Tunnel1997-04-25025 April 1997 PNO-I-97-026:on 970427,Yankee Atomic Electric Will Begin Shipment of Reactor Vessel for Disposal.First Phase of Shipment Will Involve Heavy Haul Truck from Rowe,Ma Site to Railway Approx Six Miles Away Near Hoosac Tunnel IR 05000029/19960041997-01-24024 January 1997 Insp Rept 50-029/96-04 on 961119-21.No Violations Noted. Major Areas Inspected:Insp Verified by Observation, Documentation Review &/Or Discussions W/Responsible or Involved Plant Staff IR 05000029/19960031996-10-16016 October 1996 Insp Rept 50-029/96-03 on 960827-29.No Violations Noted. Major Areas Inspected:Operations,Rp Program,Including Operations,Staffing,Mgt & Licensee Experience in Identifying & Correcting Weaknesses Re Control of Radioactive Matls ML20059D6441993-12-28028 December 1993 Notice of Violation from Insp on 930826-1118.Violation Noted:On 930826,inspector Found Several Examples of High Radiation Areas Where Licensee Did Not Barricade or Properly Control Access to Prevent Inadvertent Entry IR 05000029/19930071993-12-28028 December 1993 Insp Rept 50-029/93-07 on 930826-1118.Violation Noted. Major Areas Inspected:Posting of Radiological Areas & Other Controls,Organization & Staffing,Exposure ALARA Program & Radiological Info Available to Workers PNO-I-93-070, on 931208,last Four SGs from Yankee Rowe Plant Transported by Heavy Hauler Truck & Trailer to Rail Line Approx Six Miles from Plant.One Protester Observed.States of Ma & VT Informed1993-12-0909 December 1993 PNO-I-93-070:on 931208,last Four SGs from Yankee Rowe Plant Transported by Heavy Hauler Truck & Trailer to Rail Line Approx Six Miles from Plant.One Protester Observed.States of Ma & VT Informed PNO-I-93-067, on 931207,painted-over School Bus Containing Protestors from Citizen Awareness Network & Greenpeace Blocked Yankee Rowe Access Route in Effort to Prevent Off Site Transport of Third of Four SGs1993-12-0707 December 1993 PNO-I-93-067:on 931207,painted-over School Bus Containing Protestors from Citizen Awareness Network & Greenpeace Blocked Yankee Rowe Access Route in Effort to Prevent Off Site Transport of Third of Four SGs ML20059M5771993-11-15015 November 1993 PNO-1-93-064A:on 931116 & 17,util Plans to Ship Two of Four Steam Generators from Plant to Radwaste Depository at Barnwell,Sc.Licensee Will Evaluate Weather Conditions on Morning of Transportation.Commonwealth of Ma Informed IR 05000029/19930081993-11-0909 November 1993 Insp Rept 50-029/93-08 on 931018-19.No Violations Noted. Major Areas Inspected:Mgt Support & Audits Protected Area Barriers,Detection & Assessment Aids Protected Area Access Control of Personnel,Alarm Stations & Communications IR 05000029/19930051993-08-18018 August 1993 Insp Rept 50-029/93-05 on 930510-0731.No Violations Noted. Major Areas Inspected:Operations,Maint Engineering & Plant Support,Including Radiological Controls,Security,Fire Protection & Housekeeping & Administration IR 05000029/19930041993-06-30030 June 1993 Insp Rept 50-029/93-04 on 930308-0610.No Violations Noted. Major Areas Inspected:Posting of Radiological Areas & Other Controls Observed During Facility Tours,Organization & Staffing IR 05000029/19930021993-03-30030 March 1993 Insp Rept 50-029/93-02 on 930202-0320.No Violations Noted. Major Areas Inspected:Plant Operations,Radiological Controls,Emergency Preparedness & Quality Verification IR 05000029/19930031993-03-26026 March 1993 Insp Rept 50-029/93-03 on 930308-11.No Violations Noted. Major Areas Inspected:Mgt Support & Audits,Protected Area Barriers,Detection & Assessment Aids,Alarm Stations & Communications,Training & Qualifications & Security Locks IR 05000029/19930011993-03-0808 March 1993 Safety Insp Rept 50-029/93-01 on 930125-28.Violations Noted. Major Areas Inspected:Review of Various Licensee Programs, Procedures,Repts,Fire Protection,Plant Mods,Security, Emergency Preparedness & Housekeeping IR 05000029/19920111993-02-0505 February 1993 Insp Rept 50-029/92-11 on 921114-930201.No Violations Noted. Major Areas Inspected:Plant Operations,Radiological Control, Security,Engineering & Technical Support & Safety Assessment & Quality Verification IR 05000029/19920101992-11-23023 November 1992 Insp Rept 50-029/92-10 on 921104-06.One Open Items Noted. Major Areas Inspected:Contamination Monitoring of Guardhouse,Postings & Other Controls,Radiological Control of Work in Progress & Organization & Staffing ML20127F1051992-11-23023 November 1992 Corrected Cover Page for Insp Rept 50-029/92-10 on 921104-06.No Radiological Safety Concerns or Violations Noted.Major Areas Inspected:Contamination Monitoring at Guardhouse,Postings & Other Controls Observed During Tours ML20024H5671991-05-30030 May 1991 Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $50,000.Noncompliance Noted:Qa Program Did Not Provide for Adequate Training of Electrical Personnel Who Installed Electrical Connections on EDGs IR 05000029/19910041991-04-23023 April 1991 Safety Insp Rept 50-029/91-04 on 910220-0415.No Violations or Deviations Noted.Major Areas Inspected:Plant Operations, Radiological Controls,Maint & Surveillance,Security, Engineering & Technical Support,Safety Assessment & Quality IR 05000029/19910011991-02-26026 February 1991 Insp Rept 50-029/91-01 on 910103-0219.No Violations Noted. Major Areas Inspected:Daytime & Backshifts of Plant Operation,Radiological Controls,Maint & Surveillance Engineering & Technical Support & Security IR 05000029/19910021991-02-22022 February 1991 Insp Rept 50-029/91-02 on 910204-08.No Violations Noted. Major Areas Inspected:Radiological Controls Program, Including & Staffing,External Exposure Controls,Internal Exposure Controls,Audits & Appraisals & ALARA IR 05000029/19900251991-01-23023 January 1991 Insp Rept 50-029/90-25 on 901114-910102.No Violations Noted. Major Areas Inspected:Plant Operations,Radiological Control, Maint & Surveillance,Security,Engineering & Technical Support,Safety Assessment & Quality Verification IR 05000029/19900231990-12-0505 December 1990 Insp Rept 50-029/90-23 on 901105-09.No Violations Noted. Major Areas Inspected:Liquid & Gaseous Radioactive Effluent Controls & Radiological Environ Monitoring Programs ML20062H0801990-11-19019 November 1990 Insp Rept 50-029/90-21 on 901015-19.Noncited Violation Noted.Areas Inspected:Response to Bulletin 79-14 Re Seismic Analysis of as-built safety-related Piping Sys PNO-I-90-096, on 901109,reactor Manually Tripped Following Receipt of Alarms Indicating Automatic Scram Occurred1990-11-0909 November 1990 PNO-I-90-096:on 901109,reactor Manually Tripped Following Receipt of Alarms Indicating Automatic Scram Occurred ML20197H7151990-11-0606 November 1990 Notice of Violation from Insp on 900821-1001.Violation Noted:Corrective Action Implemented as Result of Failures of Emergency Lighting Surveillance Test Failed to Preclude Repetition of Failures ML20058D2871990-10-19019 October 1990 Notice of Violation from Insp on 900802-27.Violation Noted:Failure to Adequately Test EDGs After Major Overhaul IR 05000029/19900811990-09-28028 September 1990 Insp Rept 50-029/90-81 on 900709-20 & 0806-10.Weaknesses & Unresolved Item Noted.Major Areas Inspected:Maint Program IR 05000029/19900121990-09-24024 September 1990 Insp Rept 50-029/90-12 on 900619-0820.Violations Noted. Major Areas Inspected:Plant Operations,Radiological Controls,Maint & Surveillance,Security,Engineering/Technical Support,Safety Assessment/Quality Verification & Repts ML20058D3651990-09-14014 September 1990 Insp Rept 50-029/90-17 on 900730-0803.No Violations Noted. Major Areas Inspected:Audit of Licensee Action in Response to Recommendation Described in Generic Ltr 88-17 ML20059K7171990-09-0707 September 1990 Insp Rept 50-029/90-14 on 900802-27.Violations Noted Re Failure to Demonstrate Emergency Diesel Generators Operability at Required Capacity Under Design Basis Conditions.Major Areas Inspected:Emergency Diesel Generator IR 05000029/19900131990-08-0303 August 1990 Insp Rept 50-029/90-13 on 900709-13.One Noncited Violation Noted.Major Areas Inspected:Implementation of Radiation Protection Program During Current Refueling Outage & Review of Training & Qualification of Contractor Technicians IR 05000029/19900111990-08-0101 August 1990 Insp Rept 50-029/90-11 on 900619-22.No Violations or Deviations Noted.Major Areas Inspected:Safety Injection Tank Design & Replacement Procedures Together W/Walkdown of Safety Injection Sys Pumps,Valves & Piping IR 05000029/19900061990-07-24024 July 1990 Exam Rept 50-029/90-06OL on 900619-21.Exam Results:All Three Candidates Passed Exams & Issued Licenses IR 05000029/19900091990-07-16016 July 1990 Insp Rept 50-029/90-09 on 900515-0618.No Violations Noted. Major Areas Inspected:Operational Safety,Plant Operations, Radiological Controls,Maint & Surveillance,Emergency Preparedness,Security & Engineering/Technical Support PNO-I-90-051, on 900623,two Control Rods Failed to Fully Insert During Rod Drop Test.Licensee Performing Safety Assessment to Determine Significance of Event1990-06-25025 June 1990 PNO-I-90-051:on 900623,two Control Rods Failed to Fully Insert During Rod Drop Test.Licensee Performing Safety Assessment to Determine Significance of Event IR 05000029/19900101990-06-14014 June 1990 Partially Withheld Insp Rept 50-029/90-10 on 900524 (Ref 10CFR73.21).Violations Noted.Major Areas Inspected:Licensee Security Event & Access control-vehicle IR 05000029/19900071990-06-12012 June 1990 Insp Rept 50-029/90-07 on 900403-0514.Violation & Unresolved Items Noted.Major Areas Inspected:Operational Safety,Plant Operations,Radiological Controls,Security, Maint/Surveillance & Engineering & Technical Support PNO-I-90-042, on 900519,security Discovered Unauthorized Firearm Behind Seat of Contractor Truck in Protected Area. Driver Stated Weapon Hidden Under Numerous Other Items & Slipped His Mind.Firearm Almost Rusted Closed1990-05-21021 May 1990 PNO-I-90-042:on 900519,security Discovered Unauthorized Firearm Behind Seat of Contractor Truck in Protected Area. Driver Stated Weapon Hidden Under Numerous Other Items & Slipped His Mind.Firearm Almost Rusted Closed IR 05000029/19900081990-05-18018 May 1990 Partially Withheld Physical Security Insp Rept 50-029/90-08 on 900416-20 (Ref 10CFR73.21).No Violations Noted.Major Areas Inspected:Mgt Support,Security Program Plans & Audits, Protected & Vital Area Physical Barriers & Access Controls IR 05000029/19900041990-04-30030 April 1990 Insp Rept 50-029/90-04 on 900213-0402.Two Noncited Violations Noted.Major Areas Inspected:Operational Safety, Security,Plant Operations,Maint & Surveillance,Engineering Support & Radiological Controls IR 05000029/19900021990-03-12012 March 1990 Insp Rept 50-029/90-02 on 900205-09.Deviation Noted.Major Areas inspected:post-accident Monitoring Instrumentation Per Reg Guide 1.97 IR 05000029/19900011990-03-0606 March 1990 Insp Rept 50-029/90-01 on 900103-0212.Unresolved Items Noted Re 10CFR21 Rept on Safety Class 2 U-tube HX & fitness-for- Duty Program.Major Areas Inspected:Operational Safety, Security,Plant Operations,Maint/Surveillance & LERs ML20012B3841990-03-0101 March 1990 Insp Rept 50-029/90-03 on 900205-09.No Violations Noted. Major Areas Inspected:Util Activities in Response to 900110 Leak Discovered in Safety Injection Tank 1999-08-04
[Table view] |
Text
.. _
.
-
__
_ _
..
..
G U.S. NUCLEAR REGULATORY COMMISSION
REGION I
. Docket No.
50 29 License No.
DPR-03 Report No.
50-29/96-04 Licensee:
Yankee Atomic Electric Company 580 Main Street
Bolton, Massachusetts 01740-1398
!
Facility Name:
Yankee Nuclear Power Station Location:
Rowe, Massachusetts Dates:
November 19-21,1996 Inspectors:
J. Nick, Region l Radiation Specialist M. Fairtile, NRR Project Manager Approved By:
J. White, Chief, Radiation Safety Branch Division o' Reactor Safety i
9701300180 970124 PDR ADOCK 05000029
PDR
_
~_
_
_
.
-
.
.
Report Details
SUMMARY OF FACILITY OPERATIONS On October 12,1995, the Commission served Memorandum and Order CLI-9514 to Yankee Atomic Electric Company (YAEC) concerning activities at the Yankee Nuclear Power Station (NPS) in Rowe, Massachusetts. The Order states, in part, that "the NRC's approval of the Yankee NPS Decommissioning Plan cannot be accorded further legal effect, pending an (adjudit nory] hearing opportunity," and,11at in accordance with the pre-1993 interpretatie of the decommissioning regulatiot s, "the Commission expects YAEC not to conduct any further ' major' dismantling or decommissioning activities until final approval of its (decommissioning] plan after completion of the hearing process." Subsequently, the Commission issued an Order (CLl-96-9), dated October 18,1996, which granted YAEC's Motion for Summary Disposition in a hearing convened to determine whether the decommissioning plan should be approved. Since YAEC had originally submitted the decommissioning plan before the Commission
,
amended its decommissioning regulations, and the decommissioning plan was approved i
by the NRC in February 1995, YAEC had been given approval to conduct decommissioning activities at the Yankee site per a letter from the NRC (reference
.
correspondence, dated October 28,1996, from Mr. Morton Fairtile to Mr. James Kay).
)
l Based upon issuance of the Order and correspondence, the inspectors observed YAEC's activities during routine inspections on November 19 through 21,1996. The inspectors verified by observation, documentation review, and/or discussions with responsibl3 or involved plant staff, the activities on the current work schedule and the actual activities being conducted at the site. No major safety concerns were identified by the inspectors and appropriate radiological and industrial safety practices were observed for those jobs in-progress.
Operations 02.1 Facility Tours The inspectors toured radiological controlled areas (RCAs) within the vapor containment. The inspectors noted operating air sampling equipment in various areas.
Personnel dosimetry was worn by all workers in the area. Workers had removed most of the mechanical and electrical components (duct-work, conduit, cables, and fan units)
outside the bioshield, in the vapor containment. The inspectors observed that high radiation area (HRA) and locked high radiation area (LHRA) controls were satisfactory.
All areas were posted, barricaded, and locked as required by NRC regulations and Technical Specifications. The posting and labelling of radioactive material were satisfactory. Very good radiological controls were provided by health physics technician coverage for jobs / activities in RCAs.
The inspectors toured most of the RCAs outside the vapor containment including the primary auxiliary building (PAB), the service building, the radioactive waste processing (compactor) building, the potentially contaminated area (PCA) storage building (a
,
storago/ staging area for potentially contaminated equipment and materials), and the PCA warehouse attached to the radwaste processing building.
-
-
-
.
..
Workers had previously assembled a temporary waste processing system near the ion exchange pit. The temporary waste processing system included holding tanks and an ovaporator which were planned to replace the existing waste evaporator system. The licensee had processed the first batch of contaminated water through the processing system without any major problems.
j Other electrical and mechanical systems removal was continuing in the Primary Auxiliary Building (PAB). All radiation areas (ras) and HRAs were posted and barricaded as required. Locked HRAs were maintained tocked with appropriate warning signs. Housekeeping in contaminated areas was good, and contamination control was f
j evident by the use of " step-off pads", personnel monitoring equipment (friskers), and
contaminated area postings at the boundaries. No safety or NRC regulatory concerns were noted by the inspectors.
02.2 Current Activities The removal of the reactor vessel was the main work activity during the period of this inspection. The main coolant piping had previously been cut to remove small sections where the piping was attached to the reactor vessel. Other preparations had been performed including the consolidation and solidification of dross into a liner within the reactor vessel. The vessel was to be removed in one lar0e piece. Accordingly, the reactor vessel was prepared for lifting by placing a temporary cover and lead shielding on the top of the vessel. A lifting device was attached to provide two lift points. The
'
vessel was raised out cf the reactor cavity, moved over the refueling floor, and lowered down through the equipment hatch to a specially-designed cask. The cask had been manufactured and brought to the site earlier in the year. The NRC has approved the cask as a shipping container. Shipment of the reactor vessel to the disposal site near Barnwell, South Carolina was planned for Spring 1997. Until shipment, the vessel will
'
be stored in the sealed cask at the Yankee site.
Asbestos abatement work was continuing on the secondary side in the turbine building and the old radwaste evaporator system. Secondary and support systems removal was continuing in the turbine building. Renovations of the main gatehouse were continuing and near completion. The licensee planned to move the control room functions to the gatehouse to consolidate activities in one building with the security functions in early 1997.
Other work planned for early 1997 included completion of the items mentioned above, removal of the main coolant piping, removal of the upper neutron shield tank, removal of structural steel outside the auxiliary building, decontamination of the lor, exchange pit (including removal of contaminated concrete), removal of 'the old radweste evaporator system, and starting the final site survey project.
..
.
__
. _ _ _ _ _ _
_
.
.
E1 Inspection of Licensee's 10 CFR 50.59 Safety Evaluations E1.1 General Comments (37001)
Using inspection Procedure 37001, and additional NRC guidance on environmental impacts and decommissioning costs, the inspectors determined that the three plant modifications, discussed herein, and performed by the licensee under the 1996 Engineering Design Change Requests (EDCRs), issued through November 1996, were conducted under 10 CFR 50.59 and other pertinent NRC requirements. The licent.ee properly included a 10 CFR 50.59 safety evaluation in each EDCR. The NRC has required shut down plants to also assess plant modifications for any environmental impact not previously evaluated and to verify that the modification would not cause an unanticipated increase in decommissioning costs.
E1.2 Puroose of insoection
,
,
The inspection was performed to verify that the licensee properly followed the safety criteria of 10 CFR 50.59 and the additional NRC requirements outlined above.
The three subject 1996 EDCRs inspected by the NRC were:
EDCR 95-302, Revision 2 - Yankee Reactor Pressure Vessel Removal (completed)
EDCR 96-302 - Control Room Relocation (ongoing)
EDCR 96-303 - Temporary Waste Water Processing Island (completed)
E1.3 Overall Findinas on These Three Plant Modifications Based on the inspection of these three EDCRs and of the actual modifications, the inspectors determined that thete changes do not involve an unreviewed safety question j
,
as defined in 10 CFR 50.59(a)(2). The inspectors also found that ther,e changes met all
-
other NRC guidance on decommissioning costs and environmental impacts. The inspectors observed the reactor pressure vessel removal on November 20,1996. This evolution was carried out in a very safe manner and proceeded according to plan the
)
licensee informed the inspectors that the vessel in its storage / shipping canister will not
,
be shipped offsite until early spring 1997. The NRC plans to inspect this shipment.
R1 Plant Support - Radiological Controls Program R1.1 External Exoosure Control
,
c.
Insoection Scoce (83100)
The inspectors reviewed the controls for external radiation exposure through observation of work activities, tours of the facility, interviews with personnel, and a review of licensee documents.
+
.
,m y,-
,
_
_....
l
.
t i.
b.
Observations and Findinas The inspectors observed the reactor vessel removal from the vapor containment and
,
various other work activities during the period of this inspection. Personnel in the RCA were observed wearing their assigned thermoluminescent dosimeter (TLD) and pocket ion cherober (P!C) dosimeter. The dose totals for each individual were tallied on each workday and reports were available for review by personnel. Plant management periodically reviewed the status of workers in the respective departments.
As stated in Section 02.1 of this Report, controls for radiation areas and high radiation areas were appropriate throughout the facility, in addition, the temporary controls for the reactor vessel removal project were very good. During the lift of the vessel, technicians were stationed in various areas to monitor radiation dose rates and restrict access as necessary. Actual dose rates were not as high as expected from the reactor vessel, but barriers and postings were used appropriately to prevent inadvertent entry into areas with elevated dose rates. The inspectors verified that the proper controls were placed on all sides of the reactor vessel cask.
Radiation work permits (RWPs) and a computerized access control system were also i
used to control workers' radiation exposure. The inspector reviewed selected RWPs written for various work activities and concluded that they contained appropriate requirements including administrativo dose limits, protective clothing, and special monitoring or dosimetry.
J C.
Conclusions Controls for external radiation were very good including temporary controls used during the reactor vessel removal from the vapor containment. No violations of NRC regulations or safety concerns were identified.
R1.2 Internal Exoosure Control a.
Inspection Scoce (83100)
The inspectors reviewed the controls for internal radiation exposure through observation of work activities, tours of the facility, interviews with personnel and a review of licensee documents.
b.
Observations and Findinas The inspectors observed air sampling equipment in the vapor containment during the reactor vessel removal. The equipment was positioned to provide representative sampling of the breathing air in areas occupied by workers. Air sampling was provided for workers in the reactor cavity preparing for lifting the reactor vessel and workers on the refueling floor. Although the airborne radioactivity was expected to be negligible, all workers in the vapor container were respirator qualified, and ready to don respirators if needed, due to asbestos concerns. In addition, air handling and filtration equipment was used in areas with potential airborne radioactivit..
.
5 The licensee had recently upgraded the software and hardware used to evaluate internal bioassay results. A new computer system had been installed and tested prior to the period of this inspection. The inspectors noted the improvements to the bioassay system.
The inspectors reviewed the results from bernal dose assignments and determined that the dose assigned through air sampling and bioassay were very small when compared to the total dose assignment.
c.
Conclusions The licensee had provided good controls for internal radiation exposure includmg air sampling and bicassay for dose assessment. No violations of NRC regulations and no safety concerns were noted.
R1.3 Control of Radioactive Materials and Contarnination. Surveys and Monitorina
,
a.
Insoection Scone (83100)
l The inspectors reviewed the controls for radioactive materials and contamination, surveys and monitoring through observation of work activities, tours of the facility, interviews with personnel and a review of licensee documents.
b.
Observations and Findinas The inspectors verified that there was an adequate supply of radiation survey and monitoring equipment. Al! equipment checked by the inspector was operable and within the current calibration period. Portal monitors and frisking instruments were located throughout the facility for use by workers as they left radioactive materials areas or contaminated areas. Current radiological surveys of various work locations were reviewed by the inspector. The surveys contained detailed information regarding dose rates and hazards in the work areas. Surveys were posted at the main control point for the RCA and at the vapor containment. Appropriate licensee management personnel had reviewed the radiological surveys.
The inspectors observed a technician obtaining dose rate measurements on the outside of the reactor vessel cask after loading. The technician performed the survey appropriately with the proper survey instrument. Dose rates were taken on contact with the cask and in the general areas around the cask.
Radiological housekeeping was good throughout the plant with appropriate controls established to minimize the spread of contamination. Posting of radioactive material areas and labelling of radioactive materials was appropriate. Very good controls were established to prevent the spread of contamination during the reactor vessel removal.
Plastic sheets were taped between the bottom of the equipment hatch and the top of the cask to enclose the area. Unnecessary material and items were minimized in the i
vapor container and other contaminated areas.
.
-
. -
. -
-..
-.
.
ec
c.
Qg!usions The licensee provided very good controls for radioactive materials and contamination, surveys and monitoring during decommissioning work activities. No violations or significant safety concerns were identified.
R1.4 Maintainina Occuoational Radiation Exoosures ALARA a.
Insoection Scope (83100)
Through interviews with personnel and review of several documents, the inspectors examined the program to maintain personnel exposures ALARA.
b.
Observations and Findinas i
The personnel working at the Rowe site received a total radiation exposure of I
approximately 85 person-rem during the period from January 1,1996 through November 19,1996, as measured by thermoluminescent dosimeters (TLDs) and pocket ion chambers (PICS). The highest total dose assignment to an individual at the site was 1.564 rem though November 19,1996. This is much below the NRC total annual dose limit to an occupational worker of 5.0 rem. The projected total exposure during 1996 was 91 person-rem for routine work and support of decontamination and decommissioning activities. Additional exposure was projected for dismantlement of the reactor vessel, the main coolant system, various other systems in the vapor j
containment, balance of plant systems, and other structures. Some additional exposure was projected for asbestos abatement and radioactive waste shipments. The total i
dose to personnel working on all activities at the Rowe site for the period from 1993 through August 1996 was approximately 482 person-rem. The total dose for decommissioning and dismantlement activities, including support work, was approximately 440 person-rem.
)
i The inspector reviewed the planned ALARA initiatives for the reactor vessel removal.
!
These initiatives included limiting the number of personnel in the vapor containment by establishing remote video viewing locations, erecting a lead curtain to shield the crane operator in the vapor containment, placing lead shielding on top of the reactor vessel, erecting water shield at the entrance through the bioshield wall for the crane load j
director, filling the auxiliary boiler tank with water to provide shielding in the boiler
'
room, performing a dry run to identify potential problems, and using cameras for required surveys of the reactor vessel condition. The initiatives were well-planned and j
contributed to lower total dose assignments than expected. The entire reactor vessel removal (excluding some preparations) was expected to be nearly 6 person-rem. The actual dose was approximately 4 person-rem. This low dose assignment is significant due to the high total activity contained in the reactor vessel (approximately 4500 curies) and high expected dose rates (1 rem per hour at 5 feet from the unshielded vessel) during the reactor vessel removal.
i i
-
-
-
-
-
-
'.
.
c.
_Qonclusions The licensee continued to ma'ntain an very good program for maintaining occupational radiation exposures ALARA. Effective ALARA initiatives were implemented for the reactor vessel removal project and other activities. Total occupational radiation exposure to workers at the Yankee site for the year to date was less than the projected total for the year.
R7 Quality Assurance in Radiation Protection Activities R7.1 Audits and Aooraisals a.
Insoection Scroe (8310.01
The inspectors reviewed the licensee's programs and systems for auditing and J
appraising the program for control of radiation and radioactive materials through examination of records and interviews with licensee personnel.
b.
Observations and Findinas There had been no new audits of the radiation protection program since the last inspection; however, the inspectors noted recent audits of the special nuclear materials control program, the training program, the industrial safety program, the environmental program, the REMP/RETS/ODCM programs, and the corrective action system.
Appropriate and timely corrective actions had been taken by the licensee's staff for the minor deficiencies and weaknesses that were identified during the audits performed by the quality assurance group.
The quality assurance group was continuing to perform surveillance of radiological work activities and waste shipments. The inspectors reviewed surveillance report regarding various radiological work activities. The surveillance reports indicated that the implementation of the radiation protection program was satisfactory.
c.
Conclusions The inspectors concluded that the audit, self-assessment, and corrective action programs were continuing to identify problem areas and improve the quality of the radiation protection program. No violations were identified in this area.
X1 Exit Meeting Summary The inspectors met with the licensee representatives denoted below at the conc!usion of the on-site inspection on November 21,1996. The inspectors summarized the purpose, scope, and findings of the inspection. The licensee representatives acknowledged the inspection finding._
-.
-
_. _
_ _ _ _. _
_..
..
__... __ _
_
. _.
_ _
. _ _
-
,
>
e.
l PARTIAL LIST OF PERSONS CONTACTED
!
Licensee
.
'G. Babineau, Radiation Protection and Chemistry Manager
!
'W. Black'adar, Radiation Protection Engineer l
H. Breite, YNSD, Lead Engineer
,
'W. Cox, YNSD, Radiation Protection Engineer
,
'R. Durfey, Senior Engineer / Maintenance and Construction
'N. Fatherston, Maintenance and Construction Manager
'R. Greenfeld, Radiation Protection Engineer /ALARA Program i
I R. Grippardi, YAEC, Quality Assurance Supervisor
'K. Heider, Site Manager
'S. Litchfield, Health and Safety Supervisor
.
'R. Mellor, YNSD Decommissioning Manager (via telephone)
j S. Mullet, Radiation Protection Technician
!
'A. Trudeau, Quality Services Group Senior Engineer i
"M. Vandale, Radiation Protection Senior Engineer
"B. Wood, Assistant Site Manger F. Williams, Operations Manager
.
- Denotes those individuals participating in the exit briefing held on November 21,1996.
INSPECTION PROCEDURE USED
'
IP 83100: Occupational Radiation Exposure During Decommissioning IP 37001: 10 CFR 50.59 Safety Evaluation Program
!
ITEMS OPENED, CLOSED, AND DISCUSSED
'
Ooened i
NONE i
Closed NONE Discussed NONE
.
l