CY-06-128, Final Status Survey Final Report Phase III, Rev 1, Appendix A5 Survey Unit Release Record 9527-0004, East Mountain Side

From kanterella
Jump to navigation Jump to search
Final Status Survey Final Report Phase III, Rev 1, Appendix A5 Survey Unit Release Record 9527-0004, East Mountain Side
ML070120547
Person / Time
Site: Haddam Neck File:Connecticut Yankee Atomic Power Co icon.png
Issue date: 09/18/2006
From: Newson C, Randall D
Yankee Atomic Electric Co
To:
NRC/FSME
References
9527-0004, CY-06-128
Download: ML070120547 (195)


Text

Book16ofof12 Book 8 Final Status Survey Final Report Phase III Appendix A5 Atomic Power Company Connecticut Yankee Haddam Unit Survey NeckRelease Plant Record Haddam, Connecticut 9527-0004, East Mountain Side February 2006 Revision 1, September 2006

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0004 RELEASE RECORD TABLE OF CONTENTS

1. SURVEY UNIT DESCRIPTION ......................................................... 3
2. CLASSIFICATION BASIS ................................................................. 3
3. DATA QUALITY OBJECTIVES (DQO) ............................................ 5
4. SURVEY DESIGN .............................................................................. 8
5. SURVEY IMPLEMENTATION.........................................................11
6. SURVEY RESULTS...........................................................................12
7. QUALITY CONTROL .......................................................................16
8. INVESTIGATIONS AND RESULTS.................................................17
9. REMEDIATION AND RESULTS......................................................20
10. CHANGES FROM THE FINAL STATUS SURVEY PLAN .............20
11. DATA QUALITY ASSESSMENT (DQA) .........................................20
12. ANOMALIES .....................................................................................21
13. CONCLUSION ...................................................................................21
14. ATTACHMENTS ...............................................................................22 14.1 Attachment 1 - Figures (7 pages including cover) 14.2 Attachment 2 - Sample and Statistical Data (165 pages including covers)

Revision 1

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0004 RELEASE RECORD

1. SURVEY UNIT DESCRIPTION Survey Unit 9527-0004 (East Mountain Side) is designated as Final Status Survey (FSS) Class 2 and consists of 3,500 m2 (0.86 acres) of uninhabited open land located approximately 0.10 miles from the reference coordinate system benchmark used at Haddam Neck Plant (HNP) (see Attachment 1, Figure 1).

The survey unit is bounded by a Class 3 survey unit, 9526-0000 to the north (called north as oriented with the north to south flow of the Connecticut River),

a running trail to the east, a fence to the south, and a stone wall to the west. The survey unit comprises wooded terrain with some steep rock ledge and rock outcroppings within the interior. A stream runs through the interior of the survey unit.

The soil of this survey unit meets the requirements for unrestricted release as a Class 2 survey unit under the criteria and requirements of the HNP License Termination Plan (LTP).

The reference coordinates associated with this survey unit are E015 through E025 by S045 through S062 (refer to LTP Section 5.4.4). The reference coordinates provide the maximum dimensions of a rectangle containing this survey unit. Some areas contained in this rectangle may not be part of this survey unit. The boundary of the survey unit was defined using a Global Positioning System (GPS).

2. CLASSIFICATION BASIS The survey unit was classified in accordance with Procedure RPM 5.1-10, Survey Unit Classification. The historical information, scoping analyses and characterization results provided sufficient data to designate Survey Unit 9527-0004 as Class 2 in August 2005.

The Classification Basis Summary conducted for Survey Unit 9527-0004 consisted of:

a) A review of the 10CFR50.75 (g) (1) database, b) A review of the Initial Characterization Report and the Historic Site Assessment (HSA) Supplement, c) Historic and current survey records review, d) Visual inspections and a walkdown.

A review of the 10CFR50.75 (g) (1) database report identifies six (6) documents associated with or relating to this survey unit.

a) Event PIR 80-37: Contamination was documented to be present in an area outside the restricted area. Small areas of low-level contamination were found on the facility grounds through routine survey in a normally non-radioactive area. The areas were cleaned up in 1980.

Revision 1 3

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0004 RELEASE RECORD b) Radiological Assessment Branch (RAB) memo NE-83-RA-1374 (September 1983): Results of a contamination survey outside the southeast RCA boundary has identified plant related activity in an adjacent survey unit to 9527. According to the memo the source could have been the events described by PIR 80-37.

c) Adverse Condition Report ACR 97-0994: Soil sample analysis identified plant related radioactivity on hillside east of plant (in another survey unit of 9527).

d) Scoping Survey Report 1998: Results of scoping samples performed for decommissioning characterization data. Cesium-137 was the predominate radionuclide found in this survey unit during the scoping survey. No other plant-related radionuclides were identified in this survey unit.

e) Event CR 05-0244: Tank farm material with low-level fixed contamination was found on the East Mountain Side in another survey unit of 9527. The single piece of tent material was found in survey unit 9527-0005 along the fence and about five hundred fifty (550) feet from the nearest boundary of 9527-0004.

f) Memo ISC 05-045: Periodic surveillance following final status survey.

Surveillance is required periodically by the LTP to ensure the radiological condition does not significantly change from the FSS results. The memo documents no negative change in the radiological status.

A review of the Initial and Supplemental Characterization Reports as well as the previous Classification Basis Summaries provided no additional information pertinent to classification.

Characterization was performed by Site Closure personnel in April 2005 to determine existing conditions and obtain radiological data for Final Status Survey (FSS). The reported concentrations of Cs-137 found in the soil were statistically consistent with those concentrations in wooded areas determined from off-site locations as documented by Health Physics Technical Support Document (TSD) BCY-HP-0063, Background Cs-137 Concentration in Soil. The average concentration was 0.695 pCi/g as expected; however, one (1) sample reported Cs-137 at a concentration of 2.37 pCi/g. The same sample reported Co-60 at a concentration of 0.0954 pCi/g. The basic statistical quantities (i.e., mean, standard deviation, median) for Cs-137 and Co-60 are provided in Table 1.

Revision 1 4

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0004 RELEASE RECORD Table 1 - Basic Statistical Quantities for Cs-137 and Co-60 from the Characterization Survey Parameter Cs-137 (pCi/g) Co-60 (pCi/g)

Minimum Value: 4.03E-02 -7.80E-03 Maximum Value: 2.37E+00 9.54E-02 Mean: 6.95E-01 2.21E-02 Median: 6.71E-01 1.66E-02 Standard Deviation: 5.75E-01 2.67E-02 The FSS Engineer performed a visual inspection and walkdown during July 2005 to assess the physical condition of the survey unit, evaluate access points and travel paths and identify potentially hazardous conditions.

The final designation was Class 2 based on historical information (HSA Supplement and LTP Table 2.10 and 2.11B) and characterization survey data which resulted in the expectation that no FSS sample would be reported in a concentration that that would exceed the LTP criteria.

3. DATA QUALITY OBJECTIVES (DQO)

FSS design and planning used the Data Quality Objective (DQO) process as described by the LTP, Procedure RPM 5.1-11, Preparation of Final Status Survey Plan, and the Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM). A summary of the main features of the DQO process are provided herein.

The DQO process incorporated hypothesis testing and probabilistic sampling distributions to control decision errors during data analysis. Hypothesis testing is a process based on the scientific method that compares a baseline condition to an alternate condition. The baseline condition is technically known as the null hypothesis. Hypothesis testing rests on the premise that the null hypothesis is true and that sufficient evidence must be provided for rejection. In designing the survey plan, the underlying assumption, or null hypothesis was that residual activity in the survey unit exceeded the release criteria. Rejection of the null hypothesis would satisfy the release criteria objective of the FSS. Probabilistic sampling is a preferred method to select a sample so that each item in the population being studied has a known likelihood of being included in the sample. Probabilistic sampling might include simple random sampling where every sample has the same chance of being included, or systematic random sampling where samples are arranged in some order and a random starting point is selected.

The primary objective of the Final Status Survey Plan (FSSP) was to demonstrate that the level of residual radioactivity in Survey Unit 9527-0004 did not exceed the release criteria specified in the LTP and that the potential dose from residual radioactivity is As Low As Reasonably Achievable (ALARA).

Revision 1 5

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0004 RELEASE RECORD A fundamental precursor to survey design is to establish a relationship between the release criteria and some measurable quantity. This is done through the development of Derived Concentration Guideline Values (DCGLs). The DCGLs represent average levels of radioactivity above background levels and are presented in terms of surface or mass activity concentrations. Chapter 6 of the LTP describes in detail the modeling used to develop the DCGLs for soil (called Base Case Soil DCGL), existing groundwater radioactivity and future groundwater radioactivity from building basements and footings.

The DCGLs presented in Chapter 6 of the LTP were developed for exposures from three (3) components, that is, residual radioactivity in soil, existing groundwater radioactivity, and future groundwater radioactivity from the burial of concrete foundations or footings from site buildings containing residual radioactivity. Equation 1 shows the mathematical relationship between the three (3) components and the total dose.

Equation 1:

HTotal=HSoil + HExisting GW + HFuture GW The total dose under the LTP criteria is 25 mrem/yr TEDE from all three components. The allowable total dose under the Connecticut Department of Environmental Protection (CTDEP) radiological remediation standard for Connecticut Yankee (CY) is 19 mrem/yr TEDE. To satisfy both the LTP and CY CTDEP criteria, the dose from soil must be reduced when using the existing and future groundwater dose values discussed above.

This survey unit is affected by existing groundwater (reference CY memo ISC 06-024 and the Final Status Survey Final Report Phase III). The dose contribution from existing groundwater is bounded at 2 mrem/yr TEDE based on field data.

This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no concrete foundations or footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024). The dose contribution from future groundwater, the third dose component, is therefore 0 mrem/yr TEDE.

Equation 2:

19 mrem/yrTotal=17 mrem/yrSoil+2 mrem/yrExisting GW+0 mrem/yrFuture GW The allowable dose for soil in this survey unit is 17 mrem/yr TEDE as shown by Equation 2 above. The concentration of residual radioactivity resulting in 17 mrem/yr TEDE is designated as the Operational DCGL, and has been established for the radionuclides of concern as provided in Table 2. Note, the survey design used a much smaller value for investigation than the Revision 1 6

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0004 RELEASE RECORD Operational DCGL provided by Table 2 to conservatively account for the contribution to the total dose from existing and future groundwater which had not been established at the time of planning the FSS.

Table 2 - Radionuclide Specific Base Case Soil DCGL, Operational DCGLs and Required Minimum Detectable Concentrations Radionuclide (1) Base Case Soil Operational DCGL Required MDC DCGL (pCi/g) (2) (pCi/g) (3) (pCi/g) (4)

H-3 4.12E+02 2.80E+02 1.65E+01 C-14 5.66E+00 3.85E+00 2.26E-01 Mn-54 1.74E+01 1.18E+01 6.96E-01 Fe-55 2.74E+04 1.86E+04 1.10E+03 Co-60 3.81E+00 2.59E+00 1.52E-01 Ag-108m 7.14E+00 4.86E+00 2.86E-01 Ni-63 7.23E+02 4.92E+02 2.89E+01 Sr-90 1.55E+00 1.05E+00 6.20E-02 Nb-94 7.12E+00 4.84E+00 2.85E-01 Tc-99 1.26E+01 8.57E+00 5.04E-01 Cs-134 4.67E+00 3.18E+00 1.87E-01 Cs-137 7.91E+00 5.38E+00 3.16E-01 Eu-152 1.01E+01 6.87E+00 4.04E-01 Eu-154 9.29E+00 6.32E+00 3.72E-01 Eu-155 3.92E+02 2.67E+02 1.57E+01 Pu-238 2.96E+01 2.01E+01 1.18E+00 Pu-239/240 2.67E+01 1.82E+01 1.07E+00 Pu-241 8.70E+02 5.92E+02 3.48E+01 Am-241 (5) 2.58E+01 1.75E+01 1.03E+00 Cm-243/244 2.90E+01 1.97E+01 1.16E+00 (1) Bold indicates those radionuclides considered to be Hard to Detect (HTD)

(2) The Base Case Soil DCGLs for soil are specified by the LTP in Chapter 6 and are equivalent to 25 mrem/yr TEDE (3) The Operational DCGL is equivalent to 17 mrem/yr TEDE (4) The required MDC is equivalent to 1 mrem/yr TEDE (5) Americium-241 can be analyzed by gamma and alpha spectroscopy and is considered to be Easy to Detect (ETD). The preferred result is the alpha spectroscopys when both analyses are performed.

Another important facet of the DQO process is to identify the radionuclides of concern and determine the concentration variability. Characterization was performed in April 2005 as discussed in Section 2. Cesium-137 was found to be the predominate radionuclide of concern. Cobalt-60 was included in the survey design based on the characterization survey results. The basic statistical Revision 1 7

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0004 RELEASE RECORD quantities (i.e., mean, standard deviation, median) for Cs-137 and Co-60 are provided in Table 1.

Instrument DQOs included a verification of the ability of the survey instrument to detect the radiation(s) of interest relative to the DCGL. Survey instrument response checks were required prior to issue and after the instrument had been used. Control and accountability of survey instruments was required to assure the quality and prevent the loss of data.

Laboratory DQOs and analysis results were to be reported as actual calculated results. Results reported as less than Minimum Detectable Concentration

(<MDC) would not be accepted for FSS. Sample report summaries were to include unique sample identification, analytical method, radionuclide, result, and uncertainty of two standard deviations, laboratory data qualifiers, units, and the required and observed MDC.

4. SURVEY DESIGN The level of effort associated with planning a survey is based on the complexity of the survey and nature of the hazards. To assist the FSS Engineers when preparing survey plans for FSS, guidance is provided in Procedure RPM 5.1-11, Preparation of Final Status Survey Plans. By design, the FSSP meets the ALARA criteria for soils as specified in Chapter 4 of the LTP. The FSSP uses an integrated sample design that combines scanning surveys and sampling which can be either random or biased.

Characterization was performed by Site Closure personnel in April 2005 to determine existing conditions and obtain radiological data for Final Status Survey (FSS). The DQO process determined that Cs-137 and Co-60 would be the radionuclides of concern (refer to Section 3). The sum of fractions or unity rule would be used with the individual Operational DCGLs because multiple radionuclides (Cs-137 and Co-60) were considered in the survey design. Other radionuclides identified during FSS would be evaluated to ensure adequate survey design and compliance with the unity rule.

Surrogate DCGLs were not required for this survey unit based on process knowledge from FSS of nearby adjacent areas and via screening under LTP Section 5.4.7.2, Gross Activity DCGLs. Radionuclide screening or de-selection is a process where an individual radionuclide or aggregate may be considered insignificant and eliminated from the FSS. The criteria for de-selection are concentrations less than 5% for individual radionuclides and less than 10% for aggregates.

The Elevated Measurement Comparison (EMC) did not apply to this survey unit since the survey unit is a Class 2 and discrete, elevated areas of contamination were not expected.

The Sign Test was selected as the non-parametric statistical test. The use of the Sign Test did not require the selection or use of a background reference area, Revision 1 8

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0004 RELEASE RECORD which simplified survey design and implementation. This approach was conservative since it included background Cs-137 as part of the sample set.

The number of soil samples for FSS was determined in accordance with Procedure RPM 5.1-12, Determination of the Number of Surface Samples for Final Status Survey. The Lower Bound of the Gray Region (LBGR) was set in accordance with Procedure RPM 5.1-11 to 0.5 to maintain the relative shift

) in the range of 1 and 3. A Prospective Power Curve was generated using COMPASS, a software package developed under the sponsorship of the United States Nuclear Regulatory Commission (USNRC) for implementation of the MARSSIM in support of the decommissioning license termination rule (10 CFR 20, Subpart E). The result of the COMPASS computer run showed adequate power for the survey design. Survey design specified fifteen (15) surface soil samples for non-parametric statistical testing.

The grid pattern and locations of the soil samples were determined using Visual Sample Plan (VSP) in accordance with Procedure RPM 5.1-14, Identifying, and Marking Surface Sample Locations for Final Status Survey. Visual Sample Plan was created by Pacific Northwest National Laboratory (PNNL) for the United States Department of Energy. A systematic triangular grid pattern with a random starting point was selected for sample design, which is appropriate for a Class 2 area.

Sample locations were identified using AutoCAD-Lt, a commercially available plotting software package with coordinates consistent with the Connecticut State Plane System. These coordinates were integrated with a GPS to locate sample locations in the field. Sample Measurement Locations for the design are listed with the GPS coordinates in Table 3.

Table 3 -Sample Measurement Locations with Associated GPS Coordinates Designation Northing Easting 9527-0004-001F 237259.72 668219.54 9527-0004-002F 237259.72 668273.38 9527-0004-003F 237259.72 668327.22 9527-0004-004F 237259.72 668381.06 9527-0004-005F 237259.72 668434.90 9527-0004-006F 237213.09 668246.46 9527-0004-007F 237213.09 668300.30 9527-0004-008F 237213.09 668354.14 9527-0004-009F 237213.09 668407.98 9527-0004-010F 237213.09 668461.82 9527-0004-011F 237166.47 668273.38 9527-0004-012F 237166.47 668327.22 9527-0004-013F 237166.47 668381.06 9527-0004-014F 237119.84 668354.14 9527-0004-015F 237119.84 668407.98 Revision 1 9

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0004 RELEASE RECORD A minimum of two (2) judgmental or biased samples were to be collected at locations selected by FSS Supervision based on professional judgment and observation during characterization and walkdowns to determine areas having the potential for residual radioactivity (e.g., runoff and collection, area disturbance). The number of judgmental samples represented 10% percent of the number of samples that would be used for non-parametric statistical testing.

Although Procedure RPM 5.1-11 only specified that 5% of the samples be selected for HTD analysis, three (3) soil samples or 20% of the number of samples that would be used for non-parametric statistical testing were randomly selected for HTD radionuclide analysis using the Microsoft Excel RANDBETWEEN function. Each sample would be sent off-site for a full suite analysis of the HTD radionuclides specified in the LTP, Table 2-12, Radionuclides Potentially Present at Haddam Neck Plant and as provided in Table 2.

The implementation of survey specific quality control measures as referenced by Procedure RPM 5.1-24, Split Sample Assessment for Final Status Survey, included the collection of two (2) soil samples for split sample analysis by the off-site laboratory. These locations were selected randomly using the Microsoft Excel RANDBETWEEN function. The number of quality control soil samples was determined to be 10% of the samples used for non-parametric statistical testing.

The LTP specifies that scanning will be performed in a combination of systematic and judgmental measurements for a Class 2 land area and cover 10%

to 100% of the area. The fraction of scanning coverage was determined during the DQO process with the total amount and location(s) based on the likelihood of finding elevated activity during FSS. Approximately 25% of the survey unit was to be scanned based on the characterization survey and sampling results.

For this Class 2 survey unit, the Investigation Level for soil sample measurement results and area scanning are those levels specified in LTP, Table 5-8, Investigation Levels. Note, the survey design used a much smaller value for investigation than the Operational DCGL provided by Table 2 to conservatively account for the contribution to the total dose from existing and future groundwater which had not been established at the time of planning the FSS.

Revision 1 10

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0004 RELEASE RECORD Table 4 - Synopsis of the Survey Design (1)

Feature Design Criteria Basis Based on AutoCAD-Lt and Survey Unit Land Area 3,500 m2 Visual Sample Plan calculations Type 1 and Type 2 errors were 0.05, sigma was 0.228 pCi/g, the LBGR was adjusted to 0.5 Number of Measurements 15 to maintain Relative Shift in the range of 1 and 3, Relative Shift was 2.2 Grid Spacing 16.4 Based on triangular grid Interval Spacing 14.2 Based on triangular grid 2.53 pCi/g Cs-137 Design DCGL To achieve 8 mrem/yr TEDE 1.52 pCi/g Co-60 To achieve 17 mrem/yr 5.38 pCi/g Cs-137 TEDE (2) to demonstrate Operational DCGL 2.59 pCi/g Co-60 compliance with Equation 2 of this Release Record The LTP requires >10% area Scan Survey unit Approximately 25%

coverage for Class 2 Survey Coverage of the area Units The Operational DCGL meets 2.53 pCi/g Cs-137 Soil Investigation Level the LTP criteria for a Class 2 1.52 pCi/g Co-60 survey unit The LTP specifies investigation at the MDCSCAN for a Class 2 Detectable over Scan Investigation Level survey unit when the MDCSCAN background is greater than the Operational DCGL (1) The survey design used a much smaller value for investigation than the Operational DCGL provided by Table 2 as the total dose from existing and future groundwater had not been established at the time of planning the FSS (2) The allowable dose for soil in this survey unit is 17 mrem/yr TEDE as the total dose from existing and future groundwater has been established (reference CY memo ISC 06-024 and the Final Status Survey Final Report Phase III)

5. SURVEY IMPLEMENTATION Final status survey field activities were conducted under Work Plan and Inspection Record (WP&IR) 2005-0054. The WP&IR package included a detailed FSSP, job safety analysis, job planning checklist and related procedures for reference. Daily briefings were conducted to discuss the expectations for job performance and the safety aspects of the survey. The Daily Survey Journal was used to document field activities and other information pertaining to the FSS.

Survey activities occurred August 10 through August 17, 2005.

The scan areas were marked out and scanned for elevated readings (see Attachment 2 for Scan Area Results). Scanning was performed with an Revision 1 11

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0004 RELEASE RECORD Eberline E-600 using a SPA-3 sodium iodide detector. The E-600 was operated in the rate-meter mode and used with audio response. The probe was positioned as close to the ground as possible and was moved at a scan speed of about 0.5 meters per second. Approximately 26% of the survey unit was scanned.

Using GPS coordinates, sample measurement locations were identified and marked with a surveyors flag for identification. At each sample measurement location, a one (1) meter radius around the sample flag was scanned for elevated radiation levels.

Fifteen (15) surface soil samples were collected and packaged in accordance with Haddam Neck Plant (HNP) Procedure RPM 5.1-3, Collection of Sample Media for Final Status Survey and FSS design. Samples were controlled, transported, stored, and transferred to the off-site laboratory using Chain-of-Custody (COC) protocol in accordance with Procedure RPM 5.1-5, Chain of Custody for Final Status Survey Samples.

Three (3) samples (9527-0004-004F, 9527-0004-009F and 9527-0004-012F) were randomly selected for HTD radionuclide analysis by the off-site laboratory.

Two (2) biased soil samples (9527-0004-016F and 9527-0004-017F) were collected and analyzed by the off-site laboratory for gamma spectroscopy.

The implementation of survey specific quality control measures included the collection of two (2) samples (9527-0004-002F and 9527-0004-013F) for split sample analysis by the off-site laboratory.

6. SURVEY RESULTS The seventeen (17) sample measurement locations identified in the FSS plan were scanned about a one (1) meter radius for elevated radiation levels. Table 5 provides an overview of the scan area survey. Scan area results are provided in Attachment 2.

Table 5- Scan Area Results for Sample Measurement Locations Sample Highest Logged Action Level (1)

Measurement Reading > Action Level (2)

(kcpm)

Location (kcpm) 1 12.9 13.6 No 2 17.7 18.9 No 3 25.7 22.0 Yes 4 9.22 11.2 No 5 8.84 9.88 No 6 12.4 12.4 Yes 7 19.4 12.6 Yes 8 12.1 11.3 Yes 9 8.65 8.81 No Revision 1 12

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0004 RELEASE RECORD Table 5- Scan Area Results for Sample Measurement Locations Sample Highest Logged Action Level (1)

Measurement Reading > Action Level (2)

(kcpm)

Location (kcpm) 10 5.64 6.36 No 11 7.95 9.70 No 12 10.9 11.9 No 13 7.75 9.60 No 14 8.95 10.9 No 15 7.26 8.90 No 16 12.7 14.7 No 17 13.2 13.4 No (1) The action level is based on a measurement above ambient background (2) Samples are collected from the location within the boundaries of the scan yielding a response above the action level Fifteen (15) areas were scanned for elevated radiation levels. Several elevated areas were identified and were determined to be Naturally Occurring Radioactive Material (NORM) based on the presence of rock outcroppings and the lack of soil in the area. Table 6 provides an overview of the scan area survey. Scan area results are provided in Attachment 2.

Table 6- Scan Area Results Highest Elevated Scan Logged Action Level (1) Investigation Reading Area Reading (kcpm) Sample Identification (2)

(kcpm) 1 12.1 11.6 SC-01-05-0 None (3)

SC-01-13-0 ER-01-13-1 2 32.2 13.4 ER-01-13-2 None (3)

SC-01-14-0 SC-01-15-0 None - no 3 11.2 11.4 elevated areas None identified None - no 4 12.4 13.5 elevated areas None identified None - no 5 9.84 20.9 elevated areas None identified None - no 6 9.75 10.5 elevated areas None identified Revision 1 13

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0004 RELEASE RECORD Table 6- Scan Area Results Highest Elevated Scan Logged Action Level (1) Investigation Reading Area Reading (kcpm) Sample Identification (2)

(kcpm)

None - no 7 10.0 10.6 elevated areas None identified None - no 8 10.2 10.4 elevated areas None identified None - no 9 10.1 11.4 elevated areas None identified None - no 10 9.66 10.0 elevated areas None identified None - no 11 11.9 12.8 elevated areas None identified None - no 12 11.5 12.1 elevated areas None identified ER-03-17-1 ER-03-18-1 13 37.8 17.4 ER-03-20-1 None (3)

ER-03-21-1 ER-03-23-1 SC-03-27-0 14 31.3 15.4 SC-03-30-0 None (3)

SC-03-32-0 None - no 15 15.8 19.0 elevated areas None identified (1) The action level is based on a measurement above ambient background (2) ER and SC are abbreviations associated with the barcodes used in the field where ER stands for Elevated Reading and SC refers to Scan (3) Elevated readings were determined to be due to Naturally Occurring Radioactive Material (NORM) as there were outcroppings of rock and no soil in the area (refer to Section 8).

The off-site laboratory employed for the radiological analyses of samples was General Engineering Laboratories, LLC, Charleston, South Carolina. The laboratory analyzed the fifteen (15) samples taken for non-parametric statistical testing, the associated duplicates, and the biased samples using gamma spectroscopy. Gamma spectroscopy analysis was performed to the required Revision 1 14

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0004 RELEASE RECORD MDC. Gamma spectroscopy results identified radionuclides other than Cs-137 and Co-60 meeting the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty). All could be de-selected or excluded using the 5% and 10% rule described in Section 4.

Cesium-137 was identified in all of the fifteen (15) samples. Cobalt-60 was identified in two (2) of the fifteen (15) samples. The average gamma spectroscopy results for Cs-137 were slightly higher than the concentrations of Cs-137 found in soil at off-site locations within the vicinity of the HNP as presented in the Health Physics TSD BCY-HP-0063.

None of the samples exceeded 61% of the Operational DCGL. Two (2) reported sample results exceeded the soil investigation criteria based on achieving 8 mrem/yr TEDE. Investigation was conducted in accordance with the FSSP (refer to Section 8). A summary of the sample gamma spectroscopy results is provided in Table 7.

Table 7- Summary of Soil Sample Results Cs-137 Co-60 Fraction of the Sample Number pCi/g pCi/g Operational DCGL (1) 9527-0004-001F 1.10E+00 2.74E-02 0.215 9527-0004-002F 2.75E+00 6.67E-02 0.537 9527-0004-003F 3.24E+00 1.59E-02 0.608 9527-0004-004F 5.55E-01 2.96E-02 0.115 9527-0004-005F 6.53E-01 8.33E-03 0.125 9527-0004-006F 1.42E+00 0.00E+00 0.264 9527-0004-007F 5.31E-01 4.41E-02 0.116 9527-0004-008F 1.02E+00 1.84E-02 0.197 9527-0004-009F 7.64E-01 1.93E-02 0.149 9527-0004-010F 9.04E-01 2.09E-02 0.176 9527-0004-011F 1.15E+00 1.97E-02 0.221 9527-0004-012F 1.55E+00 3.47E-02 0.302 9527-0004-013F 5.13E-01 5.56E-03 0.097 9527-0004-014F 1.86E+00 4.85E-02 0.364 9527-0004-015F 6.10E-01 1.39E-02 0.119 (1) The Operational DCGLs from Table 2 are 5.38 pCi/g for Cs-137 and 2.59 pCi/g for Co-60 and are used in conjunction with the unity rule to achieve 17 mrem/yr TEDE The off-site laboratory also processed three (3) samples for HTD analysis as required by the sample plan. The requested analyses included alpha spectroscopy, gas proportional counting, and liquid scintillation depending on the radionuclide and the measurement method. All analyses met the required MDC. Table 8 lists the results for those radionuclides meeting the accepted criteria for detection (i.e., a result greater than two standard deviations uncertainty) in more than one sample. Note, Tc-99 can be de-selected based on the 5% and 10% rules.

Revision 1 15

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0004 RELEASE RECORD Table 8-Hard-to-Detect Sample Results Tc-99 Fraction of the Sample (pCi/g) Operational DCGL (1) 9527-0004-004F 2.17E-01 0.025 9527-0004-009F 2.10E-01 0.025 9527-0004-010F 2.64E-01 0.031 (1) The Operational DCGL from Table 2 is 8.57 pCi/g for Tc-99 to achieve 17 mrem/yr TEDE Two (2) biased samples were collected at locations selected by FSS Supervision based on professional judgment and observation. Gamma spectroscopy analysis was performed by the off-site laboratory to the required MDC. A summary of the all sample results is provided in Table 9.

Table 9- Biased Sample Results Cs-137 Co-60 Fraction of the Sample Number pCi/g pCi/g Operational DCGL(1) 9527-0004-016F 9.91E-02 -9.73E-03 0.015 9527-0004-017F 4.71E-01 -3.15E-03 0.086 (1) The Operational DCGLs from Table 2 are 5.38 pCi/g for Cs-137 and 2.59 pCi/g for Co-60 and are used in conjunction with the unity rule to achieve 17 mrem/yr TEDE

7. QUALITY CONTROL The off-site laboratory processed the split samples and performed gamma spectroscopy analysis. Ten percent (10%) of the samples were selected for analysis, which exceeds the 5% minimum required by the LTP. The data were evaluated using USNRC acceptance criteria specified in Inspection Procedure 84750 as detailed in HNP Procedure RPM 5.1-24, Split Sample Assessment for Final Status Survey. There was unacceptable agreement between field split results for Cs-137 which was identified under Condition Report (CR) 05-0781.

Evaluation of the data using the reported results for NORM resulted in acceptable agreement. The source of the disagreement for Cs-137 is likely a disproportionate amount of organic material in the field splits. A review of the Daily Survey Journals (field notes) and interviews with FSS Supervision indicate this to be the apparent cause. Field Supervision noted that the rocky terrain and undergrowth made sample collection difficult (refer to Section 8 for additional discussion on this topic).

The sample analysis vendor, General Engineering Laboratories, LLC, Charleston, South Carolina, maintains quality control and quality assurance plans as part of normal operation. Refer to Attachment 2 for data and data quality analysis results.

Revision 1 16

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0004 RELEASE RECORD

8. INVESTIGATIONS AND RESULTS Fourteen (14) localized areas were found to verifiably exceed their investigation level during the scan area survey. The Daily Survey Journals described the areas as abounding with rock outcroppings covered by a thin layer (about 1 inch to 2 inch) of dead roots and dead vegetation (refer to picture 1).

Picture 1 - A view showing the topography of the survey unit looking north-northeast.

The suspected source of the high background is NORM given the survey units geology. The rock types found on the hill and under the station area consist of a suite of recrystallized volcanic rocks mapped regionally as the Monson Gneiss and Middletown Formation (refer to the HNP Historical Site Assessment Supplement). Rock outcroppings and ledges containing microcline-quartz pegmatite, a coarse grained rock of granitic composition, have been identified on HNP property (refer to Health Physics TSD CY-HP-0150, Investigation of Rock Outcropping Exhibiting Elevated Activity.) Uranium is included with the minerals associated with this pegmatite. A primary component of pegmatite intrusives is the mineral orthoclase which contains K-40. Although the concentrations of K-40 are relatively small compared to the other isotopes, it is enough to be detected during a survey considering the fact that the pegmatites are extensively injected into the bedrock.

Evaluation of the soil sample data shows that two (2) sample results were higher than the concentrations of Cs-137 found in soil at off-site locations within the vicinity of the HNP and the survey design specification for investigation (see Note in Table 4). The sample locations were 9527-0004-0002 and 9527-0004-Revision 1 17

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0004 RELEASE RECORD 0003 (the results can be found in Table 7). Confirmatory samples were collected to determine the cause and extent of contamination. The samples were analyzed by the off-site laboratory and the reported results confirmed elevated radioactivity. Additional samples were collected at sample location 9527-0004-003 and were analyzed by gamma spectroscopy on-site. Additional samples could not be collected at sample location 9527-0004-002 due to the amount of bedrock outcropping and lack of soil to collect according to the Daily Survey Journal. The on-site and off-site gamma spectroscopy results are included in Table 10.

Table 10- Confirmatory Sample Results Fraction of the Original Sample Sample Cs-137 Co-60 Operational Location Number pCi/g pCi/g DCGL (1) 9527-0004-2A 3.72E+00 0.00E+00 0.691 9527-0004-2B 3.25E+00 0.00E+00 0.604 9527-0004-002 9527-0004-2C 5.53E+00 0.00E+00 1.028 9527-0004-2D 3.41E+00 2.86E-01 0.744 9527-0004-3A 2.83E+00 1.12E-02 0.530 9527-0004-3B 3.90E+00 5.13E-02 0.745 9527-0004-3C 3.83E+00 6.92E-02 0.739 9527-0004-3D 1.40E+00 -3.24E-03 0.259 9527-0004-3E 1.58E+00 1.23E-01 0.341 9527-0004-3F 4.34E-01 1.13E-01 0.124 9527-0004-003 9527-0004-3G 1.60E+00 1.46E-01 0.354 9527-0004-3H 1.03E+00 1.35E-01 0.244 9527-0004-3I 1.07E+00 1.39E-01 0.253 9527-0004-3J 6.10E-01 1.34E-01 0.165 9527-0004-3K 5.32E-01 1.21E-01 0.146 9527-0004-3L 7.41E-01 1.23E-01 0.185 (1) The Operational DCGLs from Table 2 are 5.38 pCi/g for Cs-137 and 2.59 pCi/g for Co-60 and are used in conjunction with the unity rule to achieve 17 mrem/yr TEDE Confirmatory sample 9527-0004-002C is above the Operational DCGL which could indicate that the classification criterion for a Class 2 survey unit was exceeded. However, subtracting background from past atmospheric nuclear weapons testing yields a net Cs-137 concentration below the Operational DCGL. The concentration of Cs-137 found in off-site wooded locations was 0.819 pCi/g +/- 0.460 as documented by Health Physics Technical Support Document (TSD) BCY-HP-0063, Background Cs-137 Concentration in Soil.

The corresponding net result for confirmatory sample 9527-0004-002C is 4.71 pCi/g, a fraction of the Operational DCGL equal to 0.876. Secondly, what has been identified is a topical and likely artificially biased, increase of Cs-137 due to natural conditions and mechanisms based on the following explanation.

The likely source of the high activity in the confirmatory sample is accumulation and concentration of Cs-137 in the sample media. The media in Revision 1 18

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0004 RELEASE RECORD this case was not soil taken to a depth of 6 inches, the minimum equal depth of soil mixing used in Cy LTP conceptual model for the Resident Farmer scenario, but organic detritus and humus from decaying plant and tree material clumped in a thin, dense layer over rock. The layer of material available for sampling, 1 inch to 2 inches, would have required collecting the media horizontally as opposed to vertically to obtain sufficient sample material. This would tend to bias the Cs-137 activity high due to the increase of surficial activity (pCi/m2) across the area of collection.

Furthermore, sample location 9527-0004-002 is within an area that receives considerable runoff from the mountainside. Pooling has been observed in the area from runoff and from a nearby stream which swells into the area following heavy rainfall and during spring thaws. The area also contains a dense root system as discussed previously. The MARSSIM recognizes that vegetative cover and foreign material (e.g., plant roots) are generally not considered part of the sample and should be removed. Picture 2 clearly shows a dense root system within the layer of material available for sampling which would be difficult to remove in the field using available equipment and techniques. Cumulative bioaccumulation of deposited radionuclides from the soil to the plant roots would be another likely source of higher than expected radioactivity, especially given the down gradient location and the favorable conditions for runoff and pooling.

Picture 2 - View of sample media from 9527-0004-002 showing the root system and layer depth.

Revision 1 19

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0004 RELEASE RECORD Additional scanning was performed in two (2) small locations in February 2006 to obtain additional data relevant to the DQOs. The scanning was performed in two (2) sections of approximately nine hundred square feet (900 ft2). The Daily Survey Journals report that exposed bedrock comprises 70% to 85% of the scan area. Two (2) elevated areas were identified and the source was determined to be exposed bedrock.

9. REMEDIATION AND RESULTS Historically, no radiological remedial action as described by MARSSIM Section 5.4 was performed in this survey unit prior to or as a result of the FSS. Health Physics TSD BCY-HP-0078, ALARA Evaluation of Soil Remediation in Support of Final Status Survey, determined that remediation beyond that required to meet the release criteria to be unnecessary and that the remaining residual radioactivity in soil was ALARA.
10. CHANGES FROM THE FINAL STATUS SURVEY PLAN The survey was designed to 8 mrem/yr TEDE which was conservative and necessary at the time of FSS planning. It is no longer required as the total dose from existing and future groundwater has been established. The dose for soil used to demonstrate compliance with the LTP criteria is 17 mrem/yr TEDE as discussed in Section 2 of this Release Record.
11. DATA QUALITY ASSESSMENT (DQA)

The DQO sample design and data were reviewed in accordance with Procedure RPM 5.1-23, Data Quality Assessment, for completeness and consistency.

The sampling design had adequate power as indicated by the Retrospective Power Curve. The Sign Test was performed on the data and compared to the original assumptions of the DQOs. The Sign Test shows that the survey unit passed FSS.

Documentation was complete and legible. Surveys and sample collection were consistent with the DQOs and were sufficient to ensure that the survey unit was properly designated as Class 2.

The preliminary data review consisted of calculating basic statistical quantities (e.g., mean, median, standard deviation).

The sample standard deviation was slightly more than the value used for the survey design. This would indicate a change to the original LBGR to maintain the number of samples at fifteen to meet the Operational DCGL. However, the value of LBGR is less of a critical issue as the survey unit has passed the statistical test, and the mean and median values are well below the Operational DCGL when used in conjunction with the unity rule. Also, the retrospective power curve shows that a sufficient number of samples were collected to achieve the desired power. Therefore, the survey unit meets the release criteria with adequate power as required by the DQOs.

Revision 1 20

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0004 RELEASE RECORD The range of the data, about 3.3 standard deviations, was not unusually large.

The difference between the mean and median was 27% of the standard deviation. The difference is enough to indicate skewness in the data. The data was represented graphically through posting plots, a frequency plot, and a quantile plot. The frequency plot shows significant positive skewness as confirmed by the calculated skew of 1.5 and probably due to the differences in terrain and the collection of runoff activity in low-lying areas.

All data, assessments, and graphical representations are provided in Attachment 2.

12. ANOMALIES The anomalies associate with the disagreement between the field splits has been discussed in Section 7. The source of the disagreement for Cs-137, especially at sample location 9527-0004-0002, was likely a disproportionate amount of organic material between the field splits.

Evaluation of the data showed that one of the investigation sample results exceeded the Operational DCGL in conjunction with the unity rule. Subsequent explanation of the elevated results for Cs-137 was discussed in Section 8. The likely source of the high activity in the samples was accumulation and concentration of Cs-137 due to natural conditions and mechanisms in samples comprised of organic detritus and humus.

No other anomalies were noted.

13. CONCLUSION Survey Unit 9527-0004 has met the final DQOs of the FSS. The ALARA criteria for soils as specified in Chapter 4 of the LTP were achieved. Elevated Measurement Comparison and remediation were not required.

The sample data passed the Sign Test. The null hypothesis was rejected.

Graphical representation of data indicates significant positive skewness as that is probably due to the differences in terrain and the collection of runoff. The Retrospective Power Curve generated using COMPASS shows adequate power was achieved. One confirmatory sample, 9527-0004-002C, was above the Operational DCGL; however, this has been identified as a topical and likely artificially biased increase of Cs-137 due to natural conditions and mechanisms.

The survey unit is properly designated as Class 2.

The dose contribution from soil is less than 4 mrem/yr TEDE based on the average concentration of the samples used for non-parametric statistical sampling.

This survey unit is affected by existing groundwater (reference CY memo ISC 06-024 and the Final Status Survey Final Report Phase III). Therefore, the dose contribution from existing groundwater is bounded by 2 mrem/yr TEDE.

Revision 1 21

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0004 RELEASE RECORD This survey unit is not considered impacted by future groundwater radioactive contamination, as there are no concrete foundations or footings containing residual radioactive material within the groundwater saturated zone in the area (reference CY memo ISC 06-024 and the Final Status Survey Final Report Phase III). The dose contribution from future groundwater, the third dose component, is therefore 0 mrem/yr TEDE.

14. ATTACHMENTS 14.1 Attachment 1 - Figures 14.2 Attachment 2 - Sample and Statistical Data Revision 1 22

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0004 RELEASE RECORD Attachment 1 Figures (6 pages)

0 16 32 Feet

0 16 32 Feet

0 16 32 Feet

0 16 32 Feet

0 16 32 Feet

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0004 RELEASE RECORD Attachment 2 Sample and Statistical Data

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0004 RELEASE RECORD Attachment 2a Sample Data (138 Pages)

Table of Contents General Narrative ................................................................... 1 Chain of Custody and Supporting Documentation ............ 4 Radiological Analysis ........................................................... 9 Sample Data Summary ....................................................... 23 Quality Control Data ............................................................ 66

General Narrative ................................................................... 1 Chain of Custody and Supporting Documentation ............ 4 Radiological Analysis ........................................................... 9 Sample Data Summary ....................................................... 23 Quality Control Data ............................................................ 66

1 2

3 4

5 6

7 8

RADIOLOGICAL ANALYSIS 9

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

SDG MSR#05-2074 Method/Analysis Information Product: Alphaspec Am241, Cm, Solid ALL FSS Analytical Method: DOE EML HASL-300, Am-05-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 460839 Prep Batch Number: 455336 Dry Soil Prep GL-RAD-A-021 Batch Number: 455334 Sample ID Client ID 143553017 9527-0004-004F 143553018 9527-0004-009F 143553019 9527-0004-012F 1200931308 Method Blank (MB) 1200931309 143553017(9527-0004-004F) Sample Duplicate (DUP) 1200931310 143553017(9527-0004-004F) Matrix Spike (MS) 1200931311 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-011 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 143553017 (9527-0004-004F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information 10

All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. An NCR was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Alphaspec Pu, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu-11-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 460841 Prep Batch Number: 455336 Dry Soil Prep GL-RAD-A-021 Batch Number: 455334 Sample ID Client ID 143553017 9527-0004-004F 143553018 9527-0004-009F 143553019 9527-0004-012F 1200931312 Method Blank (MB) 1200931313 143553017(9527-0004-004F) Sample Duplicate (DUP) 1200931314 143553017(9527-0004-004F) Matrix Spike (MS) 1200931315 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-011 REV# 14.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

11

Designated QC The following sample was used for QC: 143553017 (9527-0004-004F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. An NCR was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Pu241, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Pu-11-RC Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 460843 Prep Batch Number: 455336 Dry Soil Prep GL-RAD-A-021 Batch Number: 455334 Sample ID Client ID 143553017 9527-0004-004F 143553018 9527-0004-009F 143553019 9527-0004-012F 1200931316 Method Blank (MB) 1200931317 143553017(9527-0004-004F) Sample Duplicate (DUP) 1200931318 143553017(9527-0004-004F) Matrix Spike (MS) 1200931319 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-035 REV# 7.

Calibration Information:

12

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 143553017 (9527-0004-004F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. An NCR was not generated for this SDG.

Manual Integration No manual integrations were performed on data in this batch.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Gamma,Solid-FSS GAM & ALL FSS Analytical Method: EML HASL 300, 4.5.2.3 Prep Method: Dry Soil Prep Analytical Batch Number: 455561 Prep Batch Number: 455334 Sample ID Client ID 143553001 9527-0004-001F 143553002 9527-0004-002F 143553003 9527-0004-002FS 143553004 9527-0004-003F 13

143553005 9527-0004-005F 143553006 9527-0004-006F 143553007 9527-0004-007F 143553008 9527-0004-008F 143553009 9527-0004-010F 143553010 9527-0004-011F 143553011 9527-0004-013F 143553012 9527-0004-013FS 143553013 9527-0004-014F 143553014 9527-0004-015F 143553015 9527-0004-016F 143553016 9527-0004-017F 143553017 9527-0004-004F 143553018 9527-0004-009F 143553019 9527-0004-012F 1200918812 Method Blank (MB) 1200918813 143553001(9527-0004-001F) Sample Duplicate (DUP) 1200918814 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 10.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 143553001 (9527-0004-001F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples 1200918813 (9527-0004-001F) and 143553016 (9527-0004-017F) were recounted due to high MDAs.

14

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. An NCR was not generated for this SDG.

Qualifier information Qualifier Reason Analyte Sample UI Data rejected due to low abundance. Actinium-228 143553009 Bismuth-214 143553003 143553004 Cesium-134 143553001 143553005 143553013 Cobalt-60 143553006 Thallium-208 143553016 UI Data rejected due to no valid peak. Americium-241 143553017 Bismuth-212 143553004 143553008 143553015 143553016 Method/Analysis Information Product: GFPC, Sr90, solid - 0.025 pCi/g Analytical Method: EPA 905.0 Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 457354 Prep Batch Number: 455336 Dry Soil Prep GL-RAD-A-021 Batch Number: 455334 Sample ID Client ID 143553017 9527-0004-004F 143553018 9527-0004-009F 143553019 9527-0004-012F 1200922921 Method Blank (MB) 1200922922 144089001(9106-0001-005TP-001) Sample Duplicate (DUP) 1200922923 144089001(9106-0001-005TP-001) Matrix Spike (MS) 1200922924 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-004 REV# 9.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

15

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 144089001 (9106-0001-005TP-001).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Chemical Recoveries All chemical recoveries meet the required acceptance limits for this sample set.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. An NCR was not generated for this SDG.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Tc99, Solid-ALL FSS Analytical Method: DOE EML HASL-300, Tc-02-RC Modified Analytical Batch Number: 455604 Sample ID Client ID 143553017 9527-0004-004F 143553018 9527-0004-009F 143553019 9527-0004-012F 1200918896 Method Blank (MB) 1200918897 143735017(3000-0000-205-C-1C-03) Sample Duplicate (DUP) 1200918898 143735017(3000-0000-205-C-1C-03) Matrix Spike (MS) 1200918899 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in 16

accordance with GL-RAD-A-005 REV# 12.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 143735017 (3000-0000-205-C-1C-03).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. An NCR was not generated for this SDG.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint Fe55, Solid-ALL FSS Analytical Method: DOE RESL Fe-1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 457431 Prep Batch Number: 455336 Dry Soil Prep GL-RAD-A-021 Batch Number: 455334 Sample ID Client ID 143553017 9527-0004-004F 17

143553018 9527-0004-009F 143553019 9527-0004-012F 1200923109 Method Blank (MB) 1200923110 144089001(9106-0001-005TP-001) Sample Duplicate (DUP) 1200923111 144089001(9106-0001-005TP-001) Matrix Spike (MS) 1200923112 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-040 REV# 3.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 144089001 (9106-0001-005TP-001).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. An NCR was not generated for this SDG.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information 18

Product: Liquid Scint Ni63, Solid-ALL FSS Analytical Method: DOE RESL Ni-1, Modified Prep Method: Ash Soil Prep Dry Soil Prep GL-RAD-A-021 Method: Dry Soil Prep Analytical Batch Number: 457432 Prep Batch Number: 455336 Dry Soil Prep GL-RAD-A-021 Batch Number: 455334 Sample ID Client ID 143553017 9527-0004-004F 143553018 9527-0004-009F 143553019 9527-0004-012F 1200923113 Method Blank (MB) 1200923114 144089001(9106-0001-005TP-001) Sample Duplicate (DUP) 1200923115 144089001(9106-0001-005TP-001) Matrix Spike (MS) 1200923116 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-022 REV# 7.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 144089001 (9106-0001-005TP-001).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

19

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. An NCR was not generated for this SDG.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: LSC, Tritium Dist, Solid-HTD2,ALL FSS Analytical Method: EPA 906.0 Modified Analytical Batch Number: 455633 Sample ID Client ID 143553017 9527-0004-004F 143553018 9527-0004-009F 143553019 9527-0004-012F 1200918968 Method Blank (MB) 1200918969 143553017(9527-0004-004F) Sample Duplicate (DUP) 1200918970 143553017(9527-0004-004F) Matrix Spike (MS) 1200918971 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-002 REV# 10.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 143553017 (9527-0004-004F).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information 20

All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis Samples 1200918969 (9527-0004-004F), 143553017 (9527-0004-004F), and 143553018 (9527-0004-009F) were recounted due to high MDAs.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. An NCR was not generated for this SDG.

Qualifier information Manual qualifiers were not required.

Method/Analysis Information Product: Liquid Scint C14, Solid All,FSS Analytical Method: EPA EERF C-01 Modified Analytical Batch Number: 459955 Sample ID Client ID 143553017 9527-0004-004F 143553018 9527-0004-009F 143553019 9527-0004-012F 1200929172 Method Blank (MB) 1200929173 143553017(9527-0004-004F) Sample Duplicate (DUP) 1200929174 143553017(9527-0004-004F) Matrix Spike (MS) 1200929175 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-003 REV# 8.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 143553017 (9527-0004-004F).

QC Information All of the QC samples met the required acceptance limits.

21

Technical Information:

Holding Time All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. An NCR was not generated for this SDG.

Qualifier information Manual qualifiers were not required.

Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.

The following data validator verified the information presented in this case narrative:

Reviewer:__________________________________________________________________________

22

SAMPLE DATA

SUMMARY

23

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANK001 Connecticut Yankee Atomic Power Co.

Client SDG: MSR#05-2074 GEL Work Order: 143553 The Qualifiers in this report are defined as follows:

    • Indicates the analyte is a surrogate compound.

< Result is less than amount reported.

> Result is greater than amount reported.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

P The response between the confirmation and the primary columns is >40% Different.

R Sample results are rejected.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Lab-specific qualifier-please see case narrative, data summary package or contact your project manager for details.

Y QC Samples were not spiked with this compound.

Z Paint Filter qualifier: Particulates passed through the filter. No free liquids were observed.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

    • Indicates the analyte is a surrogate compound.

This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.

Reviewed by 24

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004001F Project: YANK01204 Sample ID: 143553001 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 10AUG05 Receive Date: 19AUG05 Collector: Client Moisture: 17.6%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Rad Gamma Spec Analysis Gamma,SolidFSS GAM & ALL FSS Actinium228 0.962 +/0.271 0.0761 +/0.266 0.162 pCi/g JPH1 09/02/05 0948 455561 1 Americium241 U 0.0476 +/0.154 0.113 +/0.151 0.234 pCi/g Bismuth212 0.763 +/0.366 0.177 +/0.358 0.374 pCi/g Bismuth214 1.05 +/0.159 0.0462 +/0.156 0.0967 pCi/g Cesium134 UUI 0.00 +/0.0478 0.0292 +/0.0468 0.0613 pCi/g Cesium137 1.10 +/0.116 0.0208 +/0.114 0.0441 pCi/g Cobalt60 U 0.0274 +/0.0288 0.0249 +/0.0282 0.0536 pCi/g Europium152 U 0.0237 +/0.0742 0.0616 +/0.0727 0.129 pCi/g Europium154 U 0.0118 +/0.0734 0.0591 +/0.072 0.129 pCi/g Europium155 U 0.0818 +/0.0865 0.0722 +/0.0848 0.149 pCi/g Lead212 1.17 +/0.127 0.0342 +/0.124 0.0709 pCi/g Lead214 1.26 +/0.177 0.0428 +/0.173 0.0894 pCi/g Manganese54 U 0.0293 +/0.037 0.0211 +/0.0362 0.0448 pCi/g Niobium94 U 0.00669 +/0.0254 0.0194 +/0.0248 0.0411 pCi/g Potassium40 11.1 +/1.38 0.208 +/1.35 0.454 pCi/g Radium226 1.05 +/0.159 0.0462 +/0.156 0.0967 pCi/g Silver108m U 0.0028 +/0.0251 0.0202 +/0.0246 0.0423 pCi/g Thallium208 0.367 +/0.0691 0.0204 +/0.0677 0.0432 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GLRADA021 TC1 08/24/05 1104 455334 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows :

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

25

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004001F Project: YANK01204 Sample ID: 143553001 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

The above sample is reported on a dry weight basis.

26

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004002F Project: YANK01204 Sample ID: 143553002 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 10AUG05 Receive Date: 19AUG05 Collector: Client Moisture: 31.2%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Rad Gamma Spec Analysis Gamma,SolidFSS GAM & ALL FSS Actinium228 U 0.286 +/0.341 0.224 +/0.334 0.477 pCi/g JPH1 09/02/05 1741 455561 1 Americium241 U 0.0892 +/0.100 0.0656 +/0.0983 0.135 pCi/g Bismuth212 U 0.155 +/0.545 0.406 +/0.534 0.870 pCi/g Bismuth214 1.03 +/0.308 0.109 +/0.302 0.230 pCi/g Cesium134 U 0.0155 +/0.0748 0.0584 +/0.0733 0.126 pCi/g Cesium137 2.75 +/0.303 0.0594 +/0.297 0.126 pCi/g Cobalt60 U 0.0667 +/0.073 0.0641 +/0.0715 0.140 pCi/g Europium152 U 0.033 +/0.182 0.139 +/0.178 0.290 pCi/g Europium154 U 0.0976 +/0.107 0.160 +/0.105 0.352 pCi/g Europium155 U 0.136 +/0.158 0.110 +/0.155 0.226 pCi/g Lead212 0.248 +/0.192 0.0778 +/0.188 0.161 pCi/g Lead214 1.14 +/0.344 0.106 +/0.337 0.221 pCi/g Manganese54 U 0.048 +/0.0663 0.0495 +/0.065 0.107 pCi/g Niobium94 U 0.0722 +/0.0658 0.0547 +/0.0645 0.116 pCi/g Potassium40 2.77 +/1.74 0.426 +/1.70 0.970 pCi/g Radium226 1.03 +/0.308 0.109 +/0.302 0.230 pCi/g Silver108m U 0.0335 +/0.0683 0.054 +/0.0669 0.113 pCi/g Thallium208 U 0.0873 +/0.115 0.0549 +/0.113 0.116 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GLRADA021 TC1 08/24/05 1104 455334 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows :

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

27

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004002F Project: YANK01204 Sample ID: 143553002 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

The above sample is reported on a dry weight basis.

28

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004002FS Project: YANK01204 Sample ID: 143553003 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 10AUG05 Receive Date: 19AUG05 Collector: Client Moisture: 34.2%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Rad Gamma Spec Analysis Gamma,SolidFSS GAM & ALL FSS Actinium228 U 0.449 +/0.612 0.244 +/0.600 0.507 pCi/g JPH1 09/02/05 1506 455561 1 Americium241 U 0.013 +/0.0866 0.0641 +/0.0849 0.131 pCi/g Bismuth212 U 0.380 +/0.543 0.445 +/0.532 0.928 pCi/g Bismuth214 UUI 0.00 +/0.318 0.176 +/0.312 0.359 pCi/g Cesium134 U 0.0455 +/0.0744 0.0565 +/0.0729 0.119 pCi/g Cesium137 4.44 +/0.440 0.058 +/0.431 0.121 pCi/g Cobalt60 U 0.100 +/0.0675 0.0604 +/0.0662 0.128 pCi/g Europium152 U 0.047 +/0.179 0.137 +/0.176 0.283 pCi/g Europium154 U 0.0444 +/0.195 0.160 +/0.191 0.340 pCi/g Europium155 U 0.125 +/0.172 0.0988 +/0.169 0.203 pCi/g Lead212 0.384 +/0.164 0.0753 +/0.161 0.155 pCi/g Lead214 1.42 +/0.303 0.0968 +/0.297 0.200 pCi/g Manganese54 U 0.0236 +/0.0672 0.0517 +/0.0658 0.109 pCi/g Niobium94 U 0.0214 +/0.0617 0.0481 +/0.0605 0.100 pCi/g Potassium40 4.23 +/1.85 0.517 +/1.82 1.11 pCi/g Radium226 1.23 +/0.318 0.102 +/0.312 0.211 pCi/g Silver108m U 0.0517 +/0.0663 0.049 +/0.065 0.101 pCi/g Thallium208 U 0.106 +/0.128 0.0545 +/0.126 0.113 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GLRADA021 TC1 08/24/05 1104 455334 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows :

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

29

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004002FS Project: YANK01204 Sample ID: 143553003 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

The above sample is reported on a dry weight basis.

30

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004003F Project: YANK01204 Sample ID: 143553004 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 10AUG05 Receive Date: 19AUG05 Collector: Client Moisture: 16.5%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Rad Gamma Spec Analysis Gamma,SolidFSS GAM & ALL FSS Actinium228 0.600 +/0.353 0.134 +/0.346 0.303 pCi/g JPH1 09/02/05 1507 455561 1 Americium241 U 0.0796 +/0.0996 0.0416 +/0.0976 0.0879 pCi/g Bismuth212 UUI 0.00 +/0.652 0.229 +/0.639 0.527 pCi/g Bismuth214 UUI 0.00 +/0.255 0.170 +/0.250 0.353 pCi/g Cesium134 U 0.0629 +/0.0583 0.0519 +/0.0572 0.114 pCi/g Cesium137 3.24 +/0.354 0.0476 +/0.347 0.104 pCi/g Cobalt60 U 0.0159 +/0.063 0.0521 +/0.0618 0.118 pCi/g Europium152 U 0.0877 +/0.142 0.115 +/0.139 0.244 pCi/g Europium154 U 0.0195 +/0.178 0.139 +/0.174 0.315 pCi/g Europium155 U 0.0136 +/0.0975 0.0706 +/0.0956 0.150 pCi/g Lead212 0.586 +/0.160 0.0641 +/0.157 0.135 pCi/g Lead214 0.996 +/0.222 0.0717 +/0.217 0.154 pCi/g Manganese54 U 0.0442 +/0.053 0.0354 +/0.0519 0.0802 pCi/g Niobium94 U 0.0126 +/0.0476 0.0361 +/0.0466 0.0797 pCi/g Potassium40 7.95 +/1.84 0.400 +/1.81 0.939 pCi/g Radium226 0.662 +/0.255 0.0848 +/0.250 0.184 pCi/g Silver108m U 0.0604 +/0.0582 0.042 +/0.057 0.090 pCi/g Thallium208 0.271 +/0.0904 0.0403 +/0.0886 0.0884 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GLRADA021 TC1 08/24/05 1104 455334 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows :

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

31

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004003F Project: YANK01204 Sample ID: 143553004 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

The above sample is reported on a dry weight basis.

32

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004005F Project: YANK01204 Sample ID: 143553005 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 10AUG05 Receive Date: 19AUG05 Collector: Client Moisture: 7.42%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Rad Gamma Spec Analysis Gamma,SolidFSS GAM & ALL FSS Actinium228 0.931 +/0.235 0.0647 +/0.231 0.140 pCi/g JPH1 09/02/05 1508 455561 1 Americium241 U 0.179 +/0.188 0.119 +/0.184 0.247 pCi/g Bismuth212 U 0.306 +/0.357 0.158 +/0.350 0.338 pCi/g Bismuth214 0.834 +/0.139 0.0398 +/0.136 0.0845 pCi/g Cesium134 UUI 0.00 +/0.0332 0.0246 +/0.0325 0.0525 pCi/g Cesium137 0.653 +/0.0807 0.0184 +/0.0791 0.0396 pCi/g Cobalt60 U 0.00833 +/0.0237 0.020 +/0.0232 0.0443 pCi/g Europium152 U 0.0303 +/0.0655 0.0554 +/0.0642 0.117 pCi/g Europium154 U 0.0195 +/0.0737 0.0616 +/0.0722 0.135 pCi/g Europium155 U 0.00939 +/0.0786 0.0702 +/0.077 0.146 pCi/g Lead212 0.919 +/0.107 0.0375 +/0.105 0.078 pCi/g Lead214 0.965 +/0.146 0.041 +/0.143 0.0862 pCi/g Manganese54 U 0.0122 +/0.0241 0.0195 +/0.0236 0.0419 pCi/g Niobium94 U 0.00705 +/0.0229 0.0181 +/0.0224 0.0387 pCi/g Potassium40 11.7 +/1.33 0.164 +/1.30 0.369 pCi/g Radium226 0.834 +/0.139 0.0398 +/0.136 0.0845 pCi/g Silver108m U 0.00326 +/0.0211 0.0182 +/0.0207 0.0386 pCi/g Thallium208 0.266 +/0.0608 0.0203 +/0.0596 0.0432 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GLRADA021 TC1 08/24/05 1104 455334 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows :

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

33

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004005F Project: YANK01204 Sample ID: 143553005 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

The above sample is reported on a dry weight basis.

34

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004006F Project: YANK01204 Sample ID: 143553006 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 10AUG05 Receive Date: 19AUG05 Collector: Client Moisture: 37%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Rad Gamma Spec Analysis Gamma,SolidFSS GAM & ALL FSS Actinium228 0.627 +/0.232 0.0881 +/0.227 0.192 pCi/g JPH1 09/02/05 1508 455561 1 Americium241 U 0.0029 +/0.110 0.0813 +/0.107 0.170 pCi/g Bismuth212 U 0.319 +/0.319 0.188 +/0.313 0.406 pCi/g Bismuth214 0.658 +/0.149 0.050 +/0.146 0.107 pCi/g Cesium134 U 0.0021 +/0.0324 0.026 +/0.0317 0.0565 pCi/g Cesium137 1.42 +/0.173 0.0251 +/0.170 0.0539 pCi/g Cobalt60 UUI 0.00 +/0.0336 0.026 +/0.0329 0.0577 pCi/g Europium152 U 0.0619 +/0.0831 0.0631 +/0.0815 0.134 pCi/g Europium154 U 0.0359 +/0.0857 0.0727 +/0.084 0.161 pCi/g Europium155 U 0.0796 +/0.0918 0.0769 +/0.0899 0.160 pCi/g Lead212 0.746 +/0.111 0.0372 +/0.108 0.0782 pCi/g Lead214 0.862 +/0.175 0.0458 +/0.171 0.0972 pCi/g Manganese54 U 0.0171 +/0.0302 0.0254 +/0.0296 0.055 pCi/g Niobium94 U 0.00571 +/0.0267 0.0211 +/0.0262 0.0456 pCi/g Potassium40 6.81 +/1.02 0.228 +/1.00 0.514 pCi/g Radium226 0.658 +/0.149 0.050 +/0.146 0.107 pCi/g Silver108m U 0.0156 +/0.029 0.0218 +/0.0284 0.0466 pCi/g Thallium208 0.232 +/0.0751 0.0234 +/0.0736 0.0504 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GLRADA021 TC1 08/24/05 1104 455334 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows :

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

35

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004006F Project: YANK01204 Sample ID: 143553006 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

The above sample is reported on a dry weight basis.

36

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004007F Project: YANK01204 Sample ID: 143553007 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 10AUG05 Receive Date: 19AUG05 Collector: Client Moisture: 10.5%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Rad Gamma Spec Analysis Gamma,SolidFSS GAM & ALL FSS Actinium228 0.647 +/0.293 0.0995 +/0.287 0.219 pCi/g JPH1 09/02/05 1732 455561 1 Americium241 U 0.0876 +/0.153 0.120 +/0.150 0.249 pCi/g Bismuth212 U 0.181 +/0.393 0.206 +/0.385 0.452 pCi/g Bismuth214 1.12 +/0.178 0.0548 +/0.174 0.118 pCi/g Cesium134 U 0.00475 +/0.0417 0.0343 +/0.0409 0.0745 pCi/g Cesium137 0.531 +/0.0833 0.0293 +/0.0816 0.0636 pCi/g Cobalt60 U 0.0441 +/0.0383 0.0363 +/0.0375 0.0805 pCi/g Europium152 U 0.0805 +/0.0937 0.0715 +/0.0918 0.152 pCi/g Europium154 U 0.0588 +/0.110 0.0968 +/0.108 0.215 pCi/g Europium155 U 0.105 +/0.0972 0.0839 +/0.0953 0.175 pCi/g Lead212 0.618 +/0.108 0.0434 +/0.106 0.0911 pCi/g Lead214 1.25 +/0.190 0.0577 +/0.187 0.122 pCi/g Manganese54 U 0.022 +/0.0398 0.034 +/0.039 0.0734 pCi/g Niobium94 U 0.00153 +/0.0334 0.0276 +/0.0328 0.0595 pCi/g Potassium40 12.2 +/1.61 0.222 +/1.57 0.524 pCi/g Radium226 1.12 +/0.178 0.0548 +/0.174 0.118 pCi/g Silver108m U 0.00785 +/0.0318 0.025 +/0.0311 0.0536 pCi/g Thallium208 0.166 +/0.0637 0.0326 +/0.0624 0.0698 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GLRADA021 TC1 08/24/05 1104 455334 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows :

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

37

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004007F Project: YANK01204 Sample ID: 143553007 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

The above sample is reported on a dry weight basis.

38

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004008F Project: YANK01204 Sample ID: 143553008 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 10AUG05 Receive Date: 19AUG05 Collector: Client Moisture: 11.3%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Rad Gamma Spec Analysis Gamma,SolidFSS GAM & ALL FSS Actinium228 0.997 +/0.241 0.049 +/0.236 0.117 pCi/g JPH1 09/02/05 1732 455561 1 Americium241 U 0.00612 +/0.0388 0.0327 +/0.038 0.0679 pCi/g Bismuth212 UUI 0.00 +/0.426 0.209 +/0.418 0.454 pCi/g Bismuth214 0.883 +/0.168 0.0455 +/0.164 0.0986 pCi/g Cesium134 U 0.0328 +/0.0357 0.0318 +/0.035 0.069 pCi/g Cesium137 1.02 +/0.137 0.0269 +/0.135 0.0583 pCi/g Cobalt60 U 0.0184 +/0.0341 0.0299 +/0.0334 0.0672 pCi/g Europium152 U 0.0284 +/0.0744 0.0582 +/0.0729 0.125 pCi/g Europium154 U 0.0255 +/0.110 0.0923 +/0.108 0.204 pCi/g Europium155 U 0.0703 +/0.0668 0.0568 +/0.0655 0.119 pCi/g Lead212 1.10 +/0.148 0.0337 +/0.145 0.0711 pCi/g Lead214 0.992 +/0.166 0.0454 +/0.163 0.0967 pCi/g Manganese54 U 0.0108 +/0.0492 0.0263 +/0.0482 0.0576 pCi/g Niobium94 U 0.0146 +/0.0312 0.0242 +/0.0306 0.0525 pCi/g Potassium40 10.9 +/1.32 0.256 +/1.29 0.586 pCi/g Radium226 0.883 +/0.168 0.0455 +/0.164 0.0986 pCi/g Silver108m U 0.0134 +/0.0283 0.0233 +/0.0278 0.0498 pCi/g Thallium208 0.337 +/0.0725 0.0206 +/0.0711 0.0454 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GLRADA021 TC1 08/24/05 1104 455334 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows :

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

39

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004008F Project: YANK01204 Sample ID: 143553008 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

The above sample is reported on a dry weight basis.

40

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004010F Project: YANK01204 Sample ID: 143553009 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 10AUG05 Receive Date: 19AUG05 Collector: Client Moisture: 39.2%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Rad Gamma Spec Analysis Gamma,SolidFSS GAM & ALL FSS Actinium228 UUI 0.00 +/0.222 0.115 +/0.218 0.238 pCi/g JPH1 09/02/05 1732 455561 1 Americium241 U 0.0742 +/0.168 0.115 +/0.165 0.237 pCi/g Bismuth212 U 0.281 +/0.368 0.162 +/0.360 0.340 pCi/g Bismuth214 0.449 +/0.130 0.0438 +/0.128 0.0913 pCi/g Cesium134 U 0.0247 +/0.0299 0.0251 +/0.0293 0.0527 pCi/g Cesium137 0.904 +/0.101 0.0227 +/0.0989 0.0476 pCi/g Cobalt60 U 0.0209 +/0.0587 0.0305 +/0.0575 0.0642 pCi/g Europium152 U 0.0596 +/0.0741 0.0565 +/0.0726 0.118 pCi/g Europium154 U 0.00462 +/0.0943 0.0639 +/0.0924 0.137 pCi/g Europium155 U 0.0382 +/0.0856 0.0664 +/0.0838 0.137 pCi/g Lead212 0.254 +/0.0826 0.0339 +/0.081 0.0699 pCi/g Lead214 0.662 +/0.145 0.0438 +/0.142 0.0907 pCi/g Manganese54 U 0.000374 +/0.0298 0.0239 +/0.0292 0.0501 pCi/g Niobium94 U 0.0101 +/0.0269 0.0201 +/0.0264 0.0421 pCi/g Potassium40 3.75 +/0.800 0.213 +/0.784 0.459 pCi/g Radium226 0.449 +/0.130 0.0438 +/0.128 0.0913 pCi/g Silver108m U 0.00825 +/0.0267 0.0207 +/0.0262 0.0429 pCi/g Thallium208 0.078 +/0.0542 0.022 +/0.0532 0.0459 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GLRADA021 TC1 08/24/05 1104 455334 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows :

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

41

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004010F Project: YANK01204 Sample ID: 143553009 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

The above sample is reported on a dry weight basis.

42

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004011F Project: YANK01204 Sample ID: 143553010 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 10AUG05 Receive Date: 19AUG05 Collector: Client Moisture: 15.1%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Rad Gamma Spec Analysis Gamma,SolidFSS GAM & ALL FSS Actinium228 1.05 +/0.237 0.0722 +/0.233 0.156 pCi/g JPH1 09/02/05 0952 455561 1 Americium241 U 0.0052 +/0.145 0.118 +/0.142 0.242 pCi/g Bismuth212 0.775 +/0.339 0.193 +/0.332 0.408 pCi/g Bismuth214 1.10 +/0.180 0.0489 +/0.176 0.103 pCi/g Cesium134 U 0.0175 +/0.0309 0.0263 +/0.0302 0.056 pCi/g Cesium137 1.15 +/0.126 0.0242 +/0.123 0.0512 pCi/g Cobalt60 U 0.0197 +/0.0246 0.0221 +/0.0241 0.0485 pCi/g Europium152 U 0.0167 +/0.0886 0.0714 +/0.0869 0.148 pCi/g Europium154 U 0.0539 +/0.0999 0.0652 +/0.0979 0.142 pCi/g Europium155 U 0.136 +/0.150 0.0674 +/0.147 0.139 pCi/g Lead212 1.05 +/0.123 0.041 +/0.120 0.0847 pCi/g Lead214 1.38 +/0.180 0.0545 +/0.176 0.113 pCi/g Manganese54 U 0.0127 +/0.028 0.0236 +/0.0274 0.0503 pCi/g Niobium94 U 0.00376 +/0.030 0.0217 +/0.0294 0.0459 pCi/g Potassium40 12.0 +/1.21 0.181 +/1.18 0.404 pCi/g Radium226 1.10 +/0.180 0.0489 +/0.176 0.103 pCi/g Silver108m U 0.00746 +/0.0301 0.0245 +/0.0295 0.0512 pCi/g Thallium208 0.275 +/0.0747 0.0229 +/0.0732 0.0486 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GLRADA021 TC1 08/24/05 1104 455334 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows :

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

43

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004011F Project: YANK01204 Sample ID: 143553010 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

The above sample is reported on a dry weight basis.

44

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004013F Project: YANK01204 Sample ID: 143553011 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 10AUG05 Receive Date: 19AUG05 Collector: Client Moisture: 6.8%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Rad Gamma Spec Analysis Gamma,SolidFSS GAM & ALL FSS Actinium228 0.646 +/0.161 0.0603 +/0.158 0.129 pCi/g JPH1 09/02/05 0947 455561 1 Americium241 U 0.0288 +/0.0343 0.0298 +/0.0336 0.061 pCi/g Bismuth212 0.834 +/0.323 0.129 +/0.317 0.275 pCi/g Bismuth214 0.788 +/0.120 0.0345 +/0.117 0.0726 pCi/g Cesium134 U 0.0369 +/0.0258 0.0233 +/0.0253 0.0493 pCi/g Cesium137 0.513 +/0.0621 0.0188 +/0.0609 0.0397 pCi/g Cobalt60 U 0.00556 +/0.022 0.0187 +/0.0216 0.0408 pCi/g Europium152 U 0.0484 +/0.0655 0.0517 +/0.0642 0.107 pCi/g Europium154 U 0.0358 +/0.0555 0.0495 +/0.0544 0.108 pCi/g Europium155 U 0.0555 +/0.0554 0.0496 +/0.0543 0.102 pCi/g Lead212 0.671 +/0.0941 0.0269 +/0.0922 0.0555 pCi/g Lead214 0.810 +/0.121 0.034 +/0.119 0.0709 pCi/g Manganese54 U 0.0118 +/0.0241 0.0213 +/0.0236 0.0449 pCi/g Niobium94 U 0.0112 +/0.0211 0.0181 +/0.0207 0.0381 pCi/g Potassium40 9.65 +/1.05 0.158 +/1.03 0.350 pCi/g Radium226 0.788 +/0.120 0.0345 +/0.117 0.0726 pCi/g Silver108m U 0.00911 +/0.020 0.0167 +/0.0196 0.0349 pCi/g Thallium208 0.232 +/0.0563 0.0175 +/0.0552 0.0369 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GLRADA021 TC1 08/24/05 1104 455334 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows :

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

45

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004013F Project: YANK01204 Sample ID: 143553011 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

The above sample is reported on a dry weight basis.

46

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004013FS Project: YANK01204 Sample ID: 143553012 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 10AUG05 Receive Date: 19AUG05 Collector: Client Moisture: 7.99%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Rad Gamma Spec Analysis Gamma,SolidFSS GAM & ALL FSS Actinium228 0.739 +/0.181 0.0551 +/0.178 0.119 pCi/g JPH1 09/02/05 0956 455561 1 Americium241 U 0.102 +/0.0852 0.0764 +/0.0835 0.157 pCi/g Bismuth212 0.520 +/0.287 0.127 +/0.281 0.270 pCi/g Bismuth214 0.735 +/0.108 0.0335 +/0.106 0.0705 pCi/g Cesium134 U 0.0402 +/0.0331 0.0198 +/0.0324 0.0422 pCi/g Cesium137 0.842 +/0.085 0.0178 +/0.0833 0.0378 pCi/g Cobalt60 U 0.0156 +/0.0232 0.0203 +/0.0227 0.044 pCi/g Europium152 U 0.00842 +/0.0582 0.049 +/0.0571 0.102 pCi/g Europium154 U 0.0392 +/0.0619 0.0472 +/0.0607 0.104 pCi/g Europium155 U 0.0153 +/0.0588 0.0491 +/0.0576 0.101 pCi/g Lead212 0.628 +/0.0796 0.0263 +/0.0781 0.0544 pCi/g Lead214 0.844 +/0.118 0.0359 +/0.115 0.0747 pCi/g Manganese54 U 0.019 +/0.0227 0.0198 +/0.0223 0.0418 pCi/g Niobium94 U 0.00857 +/0.0194 0.0166 +/0.019 0.0351 pCi/g Potassium40 9.11 +/1.03 0.165 +/1.01 0.364 pCi/g Radium226 0.735 +/0.108 0.0335 +/0.106 0.0705 pCi/g Silver108m U 0.00512 +/0.0209 0.0169 +/0.0205 0.0353 pCi/g Thallium208 0.201 +/0.0457 0.0176 +/0.0448 0.0372 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GLRADA021 TC1 08/24/05 1104 455334 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows :

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

47

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004013FS Project: YANK01204 Sample ID: 143553012 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

The above sample is reported on a dry weight basis.

48

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004014F Project: YANK01204 Sample ID: 143553013 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 10AUG05 Receive Date: 19AUG05 Collector: Client Moisture: 20.9%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Rad Gamma Spec Analysis Gamma,SolidFSS GAM & ALL FSS Actinium228 0.667 +/0.291 0.0924 +/0.285 0.203 pCi/g JPH1 09/02/05 1733 455561 1 Americium241 U 0.101 +/0.112 0.0852 +/0.109 0.179 pCi/g Bismuth212 U 0.161 +/0.509 0.190 +/0.499 0.416 pCi/g Bismuth214 0.836 +/0.193 0.0511 +/0.190 0.110 pCi/g Cesium134 UUI 0.00 +/0.0591 0.0324 +/0.0579 0.070 pCi/g Cesium137 1.86 +/0.226 0.0265 +/0.221 0.0574 pCi/g Cobalt60 U 0.0485 +/0.0361 0.0318 +/0.0354 0.0704 pCi/g Europium152 U 0.0546 +/0.0995 0.0758 +/0.0975 0.161 pCi/g Europium154 U 0.0097 +/0.106 0.0855 +/0.104 0.189 pCi/g Europium155 U 0.0104 +/0.0985 0.078 +/0.0965 0.163 pCi/g Lead212 0.558 +/0.104 0.0446 +/0.102 0.0935 pCi/g Lead214 0.934 +/0.172 0.0524 +/0.169 0.111 pCi/g Manganese54 U 0.0255 +/0.0331 0.0236 +/0.0325 0.0519 pCi/g Niobium94 U 0.00409 +/0.033 0.026 +/0.0323 0.056 pCi/g Potassium40 5.96 +/1.05 0.255 +/1.03 0.576 pCi/g Radium226 0.836 +/0.193 0.0511 +/0.190 0.110 pCi/g Silver108m U 0.0279 +/0.035 0.0255 +/0.0343 0.0544 pCi/g Thallium208 0.222 +/0.0717 0.0216 +/0.0703 0.0474 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GLRADA021 TC1 08/24/05 1104 455334 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows :

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

49

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004014F Project: YANK01204 Sample ID: 143553013 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

The above sample is reported on a dry weight basis.

50

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004015F Project: YANK01204 Sample ID: 143553014 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 10AUG05 Receive Date: 19AUG05 Collector: Client Moisture: 23.9%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Rad Gamma Spec Analysis Gamma,SolidFSS GAM & ALL FSS Actinium228 0.983 +/0.206 0.0654 +/0.202 0.140 pCi/g JPH1 09/02/05 0956 455561 1 Americium241 U3.700E05 +/0.0266 0.0222 +/0.0261 0.0458 pCi/g Bismuth212 0.593 +/0.340 0.143 +/0.333 0.304 pCi/g Bismuth214 0.827 +/0.130 0.0319 +/0.127 0.0676 pCi/g Cesium134 U 0.0297 +/0.0307 0.0238 +/0.0301 0.0503 pCi/g Cesium137 0.610 +/0.0801 0.0156 +/0.0785 0.0335 pCi/g Cobalt60 U 0.0139 +/0.0247 0.019 +/0.0242 0.0416 pCi/g Europium152 U 0.00809 +/0.0548 0.0449 +/0.0537 0.0938 pCi/g Europium154 U 0.00395 +/0.0685 0.0553 +/0.0672 0.120 pCi/g Europium155 U 0.064 +/0.0622 0.035 +/0.0609 0.0723 pCi/g Lead212 0.840 +/0.105 0.0225 +/0.103 0.0468 pCi/g Lead214 0.985 +/0.135 0.0303 +/0.133 0.0635 pCi/g Manganese54 U 0.0293 +/0.0263 0.0173 +/0.0258 0.037 pCi/g Niobium94 U 0.0018 +/0.0204 0.0165 +/0.020 0.0351 pCi/g Potassium40 8.14 +/0.940 0.141 +/0.921 0.319 pCi/g Radium226 0.827 +/0.130 0.0319 +/0.127 0.0676 pCi/g Silver108m U5.480E05 +/0.0187 0.016 +/0.0183 0.0335 pCi/g Thallium208 0.244 +/0.0537 0.0186 +/0.0527 0.0393 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GLRADA021 TC1 08/24/05 1104 455334 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows :

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

51

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004015F Project: YANK01204 Sample ID: 143553014 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

The above sample is reported on a dry weight basis.

52

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004016F Project: YANK01204 Sample ID: 143553015 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 17AUG05 Receive Date: 19AUG05 Collector: Client Moisture: 11.9%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Rad Gamma Spec Analysis Gamma,SolidFSS GAM & ALL FSS Actinium228 0.663 +/0.195 0.0701 +/0.191 0.155 pCi/g JPH1 09/03/05 1311 455561 1 Americium241 U 0.0191 +/0.0354 0.0296 +/0.0347 0.0613 pCi/g Bismuth212 UUI 0.00 +/0.348 0.186 +/0.341 0.400 pCi/g Bismuth214 1.09 +/0.159 0.0435 +/0.155 0.0933 pCi/g Cesium134 U 0.0352 +/0.0308 0.0282 +/0.0302 0.0608 pCi/g Cesium137 0.0981 +/0.0361 0.0236 +/0.0353 0.0508 pCi/g Cobalt60 U 0.000973 +/0.0309 0.0251 +/0.0303 0.0561 pCi/g Europium152 U 0.0204 +/0.0636 0.0544 +/0.0623 0.116 pCi/g Europium154 U 0.0269 +/0.0876 0.0688 +/0.0859 0.153 pCi/g Europium155 U 0.0184 +/0.0568 0.0427 +/0.0557 0.0894 pCi/g Lead212 0.497 +/0.0832 0.0314 +/0.0815 0.0657 pCi/g Lead214 1.21 +/0.172 0.0422 +/0.169 0.0892 pCi/g Manganese54 U 0.0014 +/0.0294 0.0239 +/0.0288 0.0517 pCi/g Niobium94 U 0.00878 +/0.0248 0.0213 +/0.0243 0.0459 pCi/g Potassium40 16.3 +/1.62 0.159 +/1.59 0.377 pCi/g Radium226 1.09 +/0.159 0.0435 +/0.155 0.0933 pCi/g Silver108m U 0.00147 +/0.0199 0.0175 +/0.0195 0.0376 pCi/g Thallium208 U 0.00 +/0.0571 0.0199 +/0.0559 0.0431 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GLRADA021 TC1 08/24/05 1104 455334 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows :

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

53

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004016F Project: YANK01204 Sample ID: 143553015 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

The above sample is reported on a dry weight basis.

54

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004017F Project: YANK01204 Sample ID: 143553016 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 17AUG05 Receive Date: 19AUG05 Collector: Client Moisture: 49.1%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Rad Gamma Spec Analysis Gamma,SolidFSS GAM & ALL FSS Actinium228 0.408 +/0.144 0.0647 +/0.141 0.139 pCi/g JPH1 09/16/05 1304 455561 2 Americium241 U 0.0911 +/0.0688 0.0516 +/0.0674 0.108 pCi/g Bismuth212 UUI 0.00 +/0.286 0.129 +/0.280 0.277 pCi/g Bismuth214 0.590 +/0.121 0.0331 +/0.119 0.0701 pCi/g Cesium134 U 0.0436 +/0.0384 0.0228 +/0.0377 0.0483 pCi/g Cesium137 0.471 +/0.0726 0.0176 +/0.0711 0.0374 pCi/g Cobalt60 U 0.00315 +/0.029 0.0194 +/0.0284 0.0421 pCi/g Europium152 U 0.00172 +/0.0583 0.0463 +/0.0571 0.0971 pCi/g Europium154 U 0.0018 +/0.0705 0.0564 +/0.0691 0.122 pCi/g Europium155 U 0.0324 +/0.0618 0.0497 +/0.0605 0.103 pCi/g Lead212 0.449 +/0.0757 0.0266 +/0.0742 0.0554 pCi/g Lead214 0.739 +/0.135 0.0348 +/0.132 0.073 pCi/g Manganese54 U 0.0093 +/0.0225 0.0183 +/0.022 0.0392 pCi/g Niobium94 U 0.0124 +/0.0246 0.0179 +/0.0241 0.0377 pCi/g Potassium40 4.65 +/0.717 0.188 +/0.703 0.409 pCi/g Radium226 0.590 +/0.121 0.0331 +/0.119 0.0701 pCi/g Silver108m U 0.00376 +/0.0202 0.0155 +/0.0198 0.0328 pCi/g Thallium208 UUI 0.00 +/0.0422 0.0309 +/0.0414 0.0638 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GLRADA021 TC1 08/24/05 1104 455334 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 2 EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows :

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

55

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004017F Project: YANK01204 Sample ID: 143553016 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M BD Results below the MDC or low tracer recovery.

E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

The above sample is reported on a dry weight basis.

56

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004004F Project: YANK01204 Sample ID: 143553017 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 10AUG05 Receive Date: 19AUG05 Collector: Client Moisture: 7.98%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium241 U 0.0283 +/0.0597 0.0337 +/0.0598 0.148 pCi/g JXG1 09/18/05 1406 460839 1 Curium242 U 0.00 +/0.0687 0.00 +/0.0687 0.0949 pCi/g Curium243/244 U 0.0143 +/0.0615 0.0479 +/0.0615 0.176 pCi/g Alphaspec Pu, SolidALL FSS Plutonium238 U 0.0166 +/0.0616 0.053 +/0.0616 0.162 pCi/g JXG1 09/18/05 1406 460841 2 Plutonium239/240 U 0.0249 +/0.0218 0.0529 +/0.022 0.162 pCi/g Liquid Scint Pu241, SolidALL FSS Plutonium241 U 5.3 +/9.76 8.41 +/9.78 17.5 pCi/g JXG1 09/16/05 1256 460843 3 Rad Gamma Spec Analysis Gamma,SolidFSS GAM & ALL FSS Actinium228 0.626 +/0.305 0.101 +/0.299 0.225 pCi/g JPH1 09/03/05 1312 455561 4 Americium241 UUI 0.00 +/0.0878 0.0403 +/0.086 0.0839 pCi/g Bismuth212 0.528 +/0.423 0.205 +/0.415 0.454 pCi/g Bismuth214 0.927 +/0.178 0.0463 +/0.174 0.102 pCi/g Cesium134 U 0.0756 +/0.059 0.0419 +/0.0578 0.0902 pCi/g Cesium137 0.555 +/0.112 0.0303 +/0.110 0.0659 pCi/g Cobalt60 U 0.0296 +/0.0292 0.0315 +/0.0286 0.0716 pCi/g Europium152 U 0.0316 +/0.0838 0.0727 +/0.0821 0.155 pCi/g Europium154 U 0.0747 +/0.119 0.085 +/0.116 0.193 pCi/g Europium155 U 0.0762 +/0.123 0.0589 +/0.121 0.124 pCi/g Lead212 0.877 +/0.115 0.0357 +/0.113 0.0756 pCi/g Lead214 1.05 +/0.178 0.0468 +/0.174 0.100 pCi/g Manganese54 U 0.00833 +/0.0372 0.032 +/0.0365 0.0699 pCi/g Niobium94 U 0.00324 +/0.0306 0.0263 +/0.030 0.0574 pCi/g Potassium40 9.80 +/1.47 0.237 +/1.44 0.561 pCi/g Radium226 0.927 +/0.178 0.0463 +/0.174 0.102 pCi/g Silver108m U 0.0139 +/0.0295 0.0232 +/0.0289 0.0502 pCi/g Thallium208 0.295 +/0.0734 0.0249 +/0.0719 0.0547 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr90, solid 0.025 pCi/g Strontium90 U 0.00373 +/0.010 0.0083 +/0.010 0.0171 pCi/g EXW1 08/31/05 2039 457354 5 Rad Liquid Scintillation Analysis LSC, Tritium Dist, SolidHTD2,ALL FSS Tritium U 7.90 +/8.19 6.60 +/8.19 13.7 pCi/g MXP1 09/03/05 0607 455633 6 Liquid Scint C14, Solid All,FSS 57

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004004F Project: YANK01204 Sample ID: 143553017 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Rad Liquid Scintillation Analysis Liquid Scint C14, Solid All,FSS Carbon14 U 0.0671 +/0.0802 0.0662 +/0.0802 0.135 pCi/g BXF1 09/14/05 0632 459955 7 Liquid Scint Fe55, SolidALL FSS Iron55 U 0.550 +/64.2 43.1 +/64.2 88.7 pCi/g AF1 09/02/05 0423 457431 8 Liquid Scint Ni63, SolidALL FSS Nickel63 U 4.49 +/5.77 4.98 +/5.78 10.3 pCi/g AF1 09/03/05 0017 457432 9 Liquid Scint Tc99, SolidALL FSS Technetium99 U 0.217 +/0.165 0.133 +/0.165 0.273 pCi/g BXF1 08/31/05 0339 455604 10 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GLRADA021B PD 08/25/05 1056 455336 Dry Soil Prep Dry Soil Prep GLRADA021 TC1 08/24/05 1104 455334 The following Analytical Methods were performed Method Description 1 DOE EML HASL300, Am05RC Modified 2 DOE EML HASL300, Pu11RC Modified 3 DOE EML HASL300, Pu11RC Modified 4 EML HASL 300, 4.5.2.3 5 EPA 905.0 Modified 6 EPA 906.0 Modified 7 EPA EERF C01 Modified 8 DOE RESL Fe1, Modified 9 DOE RESL Ni1, Modified 10 DOE EML HASL300, Tc02RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium243 Alphaspec Am241, Cm, Solid ALL 88 (15%125%)

Plutonium242 Alphaspec Pu, SolidALL FSS 108 (15%125%)

Carrier/Tracer Recovery Liquid Scint Pu241, SolidALL FS 82 (25%125%)

Carrier/Tracer Recovery GFPC, Sr90, solid 0.025 pCi/g 84 (25%125%)

Carrier/Tracer Recovery Liquid Scint Fe55, SolidALL FS 85 (15%125%)

Carrier/Tracer Recovery Liquid Scint Ni63, SolidALL FS 77 (25%125%)

58

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004004F Project: YANK01204 Sample ID: 143553017 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Carrier/Tracer Recovery Liquid Scint Tc99, SolidALL FS 74 (15%125%)

Notes:

The Qualifiers in this report are defined as follows :

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

The above sample is reported on a dry weight basis.

59

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004009F Project: YANK01204 Sample ID: 143553018 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 10AUG05 Receive Date: 19AUG05 Collector: Client Moisture: 8.52%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium241 U 0.0139 +/0.0301 0.0509 +/0.0302 0.172 pCi/g JXG1 09/18/05 1406 460839 1 Curium242 U 0.00 +/0.0598 0.00 +/0.0598 0.0827 pCi/g Curium243/244 U 0.0849 +/0.104 0.0511 +/0.104 0.172 pCi/g Alphaspec Pu, SolidALL FSS Plutonium238 U 0.0296 +/0.0668 0.0456 +/0.0668 0.154 pCi/g JXG1 09/18/05 1406 460841 2 Plutonium239/240 U 0.137 +/0.0894 0.151 +/0.0904 0.365 pCi/g Liquid Scint Pu241, SolidALL FSS Plutonium241 U 1.10 +/8.88 7.41 +/8.88 15.4 pCi/g JXG1 09/16/05 1313 460843 3 Rad Gamma Spec Analysis Gamma,SolidFSS GAM & ALL FSS Actinium228 1.06 +/0.255 0.0917 +/0.250 0.205 pCi/g JPH1 09/03/05 1312 455561 4 Americium241 U 0.0731 +/0.171 0.120 +/0.168 0.250 pCi/g Bismuth212 0.906 +/0.435 0.190 +/0.426 0.421 pCi/g Bismuth214 1.04 +/0.160 0.0491 +/0.157 0.107 pCi/g Cesium134 U 0.0311 +/0.0383 0.0339 +/0.0375 0.074 pCi/g Cesium137 0.764 +/0.0872 0.028 +/0.0854 0.0611 pCi/g Cobalt60 U 0.0193 +/0.0418 0.0328 +/0.0409 0.0739 pCi/g Europium152 U 0.0439 +/0.0943 0.072 +/0.0924 0.154 pCi/g Europium154 U 0.0298 +/0.0841 0.0643 +/0.0824 0.151 pCi/g Europium155 U 0.029 +/0.086 0.0745 +/0.0843 0.156 pCi/g Lead212 0.977 +/0.100 0.0428 +/0.0983 0.0901 pCi/g Lead214 1.16 +/0.159 0.0555 +/0.156 0.118 pCi/g Manganese54 U 0.00863 +/0.0315 0.0243 +/0.0309 0.0543 pCi/g Niobium94 U 0.0106 +/0.0332 0.028 +/0.0326 0.0606 pCi/g Potassium40 11.4 +/1.43 0.204 +/1.40 0.491 pCi/g Radium226 1.04 +/0.160 0.0491 +/0.157 0.107 pCi/g Silver108m U 0.00276 +/0.0317 0.0269 +/0.0311 0.0577 pCi/g Thallium208 0.328 +/0.0657 0.024 +/0.0644 0.0527 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr90, solid 0.025 pCi/g Strontium90 U 0.00673 +/0.0111 0.00907 +/0.0111 0.0187 pCi/g EXW1 08/31/05 2103 457354 5 Rad Liquid Scintillation Analysis LSC, Tritium Dist, SolidHTD2,ALL FSS Tritium U 3.68 +/8.18 6.74 +/8.18 14.0 pCi/g MXP1 09/03/05 0659 455633 6 Liquid Scint C14, Solid All,FSS 60

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004009F Project: YANK01204 Sample ID: 143553018 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Rad Liquid Scintillation Analysis Liquid Scint C14, Solid All,FSS Carbon14 U 0.0926 +/0.081 0.0664 +/0.081 0.135 pCi/g BXF1 09/14/05 0806 459955 7 Liquid Scint Fe55, SolidALL FSS Iron55 U 43.8 +/42.1 29.0 +/42.1 59.8 pCi/g AF1 09/02/05 0440 457431 8 Liquid Scint Ni63, SolidALL FSS Nickel63 U 7.85 +/5.99 5.27 +/6.01 10.9 pCi/g AF1 09/03/05 0050 457432 9 Liquid Scint Tc99, SolidALL FSS Technetium99 U 0.210 +/0.167 0.135 +/0.167 0.277 pCi/g BXF1 08/31/05 0412 455604 10 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GLRADA021B PD 08/25/05 1056 455336 Dry Soil Prep Dry Soil Prep GLRADA021 TC1 08/24/05 1104 455334 The following Analytical Methods were performed Method Description 1 DOE EML HASL300, Am05RC Modified 2 DOE EML HASL300, Pu11RC Modified 3 DOE EML HASL300, Pu11RC Modified 4 EML HASL 300, 4.5.2.3 5 EPA 905.0 Modified 6 EPA 906.0 Modified 7 EPA EERF C01 Modified 8 DOE RESL Fe1, Modified 9 DOE RESL Ni1, Modified 10 DOE EML HASL300, Tc02RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium243 Alphaspec Am241, Cm, Solid ALL 88 (15%125%)

Plutonium242 Alphaspec Pu, SolidALL FSS 98 (15%125%)

Carrier/Tracer Recovery Liquid Scint Pu241, SolidALL FS 94 (25%125%)

Carrier/Tracer Recovery GFPC, Sr90, solid 0.025 pCi/g 82 (25%125%)

Carrier/Tracer Recovery Liquid Scint Fe55, SolidALL FS 92 (15%125%)

Carrier/Tracer Recovery Liquid Scint Ni63, SolidALL FS 76 (25%125%)

61

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004009F Project: YANK01204 Sample ID: 143553018 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Carrier/Tracer Recovery Liquid Scint Tc99, SolidALL FS 72 (15%125%)

Notes:

The Qualifiers in this report are defined as follows :

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

The above sample is reported on a dry weight basis.

62

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004012F Project: YANK01204 Sample ID: 143553019 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 10AUG05 Receive Date: 19AUG05 Collector: Client Moisture: 12.5%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Rad Alpha Spec Analysis Alphaspec Am241, Cm, Solid ALL FSS Americium241 U 0.00742 +/0.0292 0.0427 +/0.0292 0.157 pCi/g JXG1 09/18/05 1406 460839 1 Curium242 U 0.00752 +/0.0632 0.0357 +/0.0633 0.156 pCi/g Curium243/244 U 0.00744 +/0.0564 0.0525 +/0.0564 0.177 pCi/g Alphaspec Pu, SolidALL FSS Plutonium238 U 0.00193 +/0.074 0.0776 +/0.074 0.220 pCi/g JXG1 09/18/05 1406 460841 2 Plutonium239/240 U 0.0115 +/0.128 0.131 +/0.128 0.328 pCi/g Liquid Scint Pu241, SolidALL FSS Plutonium241 U 2.31 +/8.15 6.94 +/8.16 14.4 pCi/g JXG1 09/16/05 1330 460843 3 Rad Gamma Spec Analysis Gamma,SolidFSS GAM & ALL FSS Actinium228 0.867 +/0.211 0.0903 +/0.207 0.191 pCi/g JPH1 09/03/05 1312 455561 4 Americium241 U 0.00811 +/0.140 0.110 +/0.137 0.226 pCi/g Bismuth212 0.498 +/0.363 0.187 +/0.356 0.396 pCi/g Bismuth214 1.04 +/0.184 0.0454 +/0.180 0.0956 pCi/g Cesium134 U 0.0569 +/0.0454 0.0299 +/0.0445 0.063 pCi/g Cesium137 1.55 +/0.142 0.0277 +/0.139 0.0581 pCi/g Cobalt60 U 0.0347 +/0.040 0.0225 +/0.0392 0.049 pCi/g Europium152 U 0.00925 +/0.0873 0.0692 +/0.0856 0.144 pCi/g Europium154 U 0.052 +/0.0842 0.0647 +/0.0826 0.141 pCi/g Europium155 U 0.114 +/0.121 0.0732 +/0.119 0.150 pCi/g Lead212 0.926 +/0.117 0.0387 +/0.115 0.080 pCi/g Lead214 1.31 +/0.189 0.0475 +/0.185 0.0989 pCi/g Manganese54 U 0.0503 +/0.054 0.0262 +/0.0529 0.0553 pCi/g Niobium94 U 0.00715 +/0.0272 0.0225 +/0.0266 0.0474 pCi/g Potassium40 10.3 +/1.17 0.209 +/1.14 0.458 pCi/g Radium226 1.04 +/0.184 0.0454 +/0.180 0.0956 pCi/g Silver108m U 0.00112 +/0.0309 0.0243 +/0.0303 0.0507 pCi/g Thallium208 0.238 +/0.0639 0.0267 +/0.0626 0.056 pCi/g Rad Gas Flow Proportional Counting GFPC, Sr90, solid 0.025 pCi/g Strontium90 U 0.00972 +/0.0135 0.0111 +/0.0135 0.0227 pCi/g EXW1 08/31/05 2103 457354 5 Rad Liquid Scintillation Analysis LSC, Tritium Dist, SolidHTD2,ALL FSS Tritium U 1.03 +/1.81 1.57 +/1.81 3.27 pCi/g MXP1 09/02/05 0217 455633 6 Liquid Scint C14, Solid All,FSS 63

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004012F Project: YANK01204 Sample ID: 143553019 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Rad Liquid Scintillation Analysis Liquid Scint C14, Solid All,FSS Carbon14 U 0.0548 +/0.0809 0.067 +/0.0809 0.136 pCi/g BXF1 09/14/05 0941 459955 7 Liquid Scint Fe55, SolidALL FSS Iron55 U 29.4 +/50.7 34.6 +/50.7 71.3 pCi/g AF1 09/02/05 0457 457431 8 Liquid Scint Ni63, SolidALL FSS Nickel63 U 2.67 +/5.56 4.75 +/5.56 9.79 pCi/g AF1 09/03/05 0123 457432 9 Liquid Scint Tc99, SolidALL FSS Technetium99 U 0.264 +/0.181 0.145 +/0.181 0.297 pCi/g BXF1 08/31/05 0446 455604 10 The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Ash Soil Prep Ash Soil Prep, GLRADA021B PD 08/25/05 1056 455336 Dry Soil Prep Dry Soil Prep GLRADA021 TC1 08/24/05 1104 455334 The following Analytical Methods were performed Method Description 1 DOE EML HASL300, Am05RC Modified 2 DOE EML HASL300, Pu11RC Modified 3 DOE EML HASL300, Pu11RC Modified 4 EML HASL 300, 4.5.2.3 5 EPA 905.0 Modified 6 EPA 906.0 Modified 7 EPA EERF C01 Modified 8 DOE RESL Fe1, Modified 9 DOE RESL Ni1, Modified 10 DOE EML HASL300, Tc02RC Modified Surrogate/Tracer recovery Test Recovery% Acceptable Limits Americium243 Alphaspec Am241, Cm, Solid ALL 86 (15%125%)

Plutonium242 Alphaspec Pu, SolidALL FSS 92 (15%125%)

Carrier/Tracer Recovery Liquid Scint Pu241, SolidALL FS 101 (25%125%)

Carrier/Tracer Recovery GFPC, Sr90, solid 0.025 pCi/g 71 (25%125%)

Carrier/Tracer Recovery Liquid Scint Fe55, SolidALL FS 87 (15%125%)

Carrier/Tracer Recovery Liquid Scint Ni63, SolidALL FS 74 (25%125%)

64

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: September 20, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 95270004012F Project: YANK01204 Sample ID: 143553019 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Carrier/Tracer Recovery Liquid Scint Tc99, SolidALL FS 68 (15%125%)

Notes:

The Qualifiers in this report are defined as follows :

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

The above sample is reported on a dry weight basis.

65

QUALITY CONTROL DATA 66

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Report Date: September 21, 2005 Client : Connecticut Yankee Atomic Power Page 1 of 9 Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut

Contact:

Mr. Pete Hollenbeck Workorder: 143553 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Alpha Spec Batch 460839 QC1200931309 143553017 DUP Americium-241 U -0.0283 U -0.0695 pCi/g N/A (0% - 100%) JXG1 09/18/05 14:06 Uncert: +/-0.0597 +/-0.0596 TPU: +/-0.0598 +/-0.0597 Curium-242 U 0.00 U 0.0226 pCi/g (0% - 100%)

Uncert: +/-0.0687 +/-0.060 TPU: +/-0.0687 +/-0.0601 Curium-243/244 U -0.0143 U 0.0212 pCi/g N/A (0% - 100%)

Uncert: +/-0.0615 +/-0.0928 TPU: +/-0.0615 +/-0.0929 QC1200931311 LCS Americium-241 10.9 11.1 pCi/g 102 (75%-125%)

Uncert: +/-1.04 TPU: +/-1.84 Curium-242 U -0.0124 pCi/g Uncert: +/-0.0172 TPU: +/-0.0173 Curium-243/244 13.3 15.6 pCi/g 117 (75%-125%)

Uncert: +/-1.24 TPU: +/-2.48 QC1200931308 MB Americium-241 U -0.0139 pCi/g 09/18/05 14:06 Uncert: +/-0.0298 TPU: +/-0.0298 Curium-242 U 0.00 pCi/g Uncert: +/-0.0513 TPU: +/-0.0513 Curium-243/244 U 0.0133 pCi/g Uncert: +/-0.0531 TPU: +/-0.0531 QC1200931310 143553017 MS Americium-241 10.9 U -0.0283 10.5 pCi/g 96 (75%-125%) 09/18/05 14:06 Uncert: +/-0.0597 +/-0.996 TPU: +/-0.0598 +/-1.74 Curium-242 U 0.00 U -0.00697 pCi/g Uncert: +/-0.0687 +/-0.0137 TPU: +/-0.0687 +/-0.0137 Curium-243/244 13.4 U -0.0143 15.7 pCi/g 117 (75%-125%)

Uncert: +/-0.0615 +/-1.22 TPU: +/-0.0615 +/-2.45 Batch 460841 QC1200931313 143553017 DUP Plutonium-238 U 0.0166 U -0.0113 pCi/g N/A (0% - 100%) JXG1 09/18/05 14:06 67

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 143553 Page 2 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Alpha Spec Batch 460841 Uncert: +/-0.0616 +/-0.0156 TPU: +/-0.0616 +/-0.0157 Plutonium-239/240 U -0.0249 U 0.0141 pCi/g N/A (0% - 100%)

Uncert: +/-0.0218 +/-0.0871 TPU: +/-0.022 +/-0.0871 QC1200931315 LCS Plutonium-238 U -0.0414 pCi/g (75%-125%)

Uncert: +/-0.0753 TPU: +/-0.0754 Plutonium-239/240 10.1 9.11 pCi/g 91 (75%-125%)

Uncert: +/-0.892 TPU: +/-1.26 QC1200931312 MB Plutonium-238 U -0.0115 pCi/g Uncert: +/-0.0593 TPU: +/-0.0593 Plutonium-239/240 U -0.0417 pCi/g Uncert: +/-0.0865 TPU: +/-0.0866 QC1200931314 143553017 MS Plutonium-238 U 0.0166 U 0.0798 pCi/g (75%-125%)

Uncert: +/-0.0616 +/-0.111 TPU: +/-0.0616 +/-0.112 Plutonium-239/240 10.1 U -0.0249 9.61 pCi/g 95 (75%-125%)

Uncert: +/-0.0218 +/-0.908 TPU: +/-0.022 +/-1.30 Batch 460843 QC1200931317 143553017 DUP Plutonium-241 U -5.3 U 2.95 pCi/g N/A (0% - 100%) JXG1 09/16/05 14:05 Uncert: +/-9.76 +/-8.54 TPU: +/-9.78 +/-8.55 QC1200931319 LCS Plutonium-241 134 109 pCi/g 81 (75%-125%) 09/16/05 14:39 Uncert: +/-13.3 TPU: +/-18.7 QC1200931316 MB Plutonium-241 U -0.957 pCi/g 09/16/05 13:48 Uncert: +/-9.33 TPU: +/-9.33 QC1200931318 143553017 MS Plutonium-241 134 U -5.3 106 pCi/g 79 (75%-125%) 09/16/05 14:22 Uncert: +/-9.76 +/-12.3 TPU: +/-9.78 +/-17.2 Rad Gamma Spec Batch 455561 QC1200918813 143553001 DUP Actinium-228 0.962 0.742 pCi/g 26 (0% - 100%) JPH1 09/16/05 13:05 Uncert: +/-0.271 +/-0.276

+/-0.271 68

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 143553 Page 3 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Gamma Spec Batch 455561 TPU: +/-0.266 Americium-241 U -0.0476 U 0.0653 pCi/g N/A (0% - 100%)

Uncert: +/-0.154 +/-0.121 TPU: +/-0.151 +/-0.119 Bismuth-212 0.763 0.832 pCi/g 9 (0% - 100%)

Uncert: +/-0.366 +/-0.454 TPU: +/-0.358 +/-0.445 Bismuth-214 1.05 1.00 pCi/g 5 Uncert: +/-0.159 +/-0.182 TPU: +/-0.156 +/-0.179 Cesium-134 UUI 0.00 U 0.0459 pCi/g 79 (0% - 100%)

Uncert: +/-0.0478 +/-0.0675 TPU: +/-0.0468 +/-0.0661 Cesium-137 1.10 0.970 pCi/g 12 (0% - 100%)

Uncert: +/-0.116 +/-0.128 TPU: +/-0.114 +/-0.126 Cobalt-60 U 0.0274 U 0.0518 pCi/g 62 (0% - 100%)

Uncert: +/-0.0288 +/-0.0506 TPU: +/-0.0282 +/-0.0496 Europium-152 U 0.0237 U -0.0371 pCi/g N/A (0% - 100%)

Uncert: +/-0.0742 +/-0.0891 TPU: +/-0.0727 +/-0.0873 Europium-154 U 0.0118 U -0.0221 pCi/g N/A (0% - 100%)

Uncert: +/-0.0734 +/-0.0911 TPU: +/-0.072 +/-0.0893 Europium-155 U 0.0818 U 0.00729 pCi/g 167 (0% - 100%)

Uncert: +/-0.0865 +/-0.0869 TPU: +/-0.0848 +/-0.0852 Lead-212 1.17 1.06 pCi/g 9 (0% - 20%)

Uncert: +/-0.127 +/-0.130 TPU: +/-0.124 +/-0.128 Lead-214 1.26 1.03 pCi/g 20 (0% - 20%)

Uncert: +/-0.177 +/-0.175 TPU: +/-0.173 +/-0.172 Manganese-54 U 0.0293 U 0.0139 pCi/g 71 (0% - 100%)

Uncert: +/-0.037 +/-0.0343 TPU: +/-0.0362 +/-0.0336 Niobium-94 U -0.00669 U 0.00844 pCi/g N/A (0% - 100%)

Uncert: +/-0.0254 +/-0.0305 TPU: +/-0.0248 +/-0.0298 Potassium-40 11.1 10.6 pCi/g 5 (0% - 20%)

Uncert: +/-1.38 +/-1.29 TPU: +/-1.35 +/-1.27 Radium-226 1.05 1.00 pCi/g 5 (0% - 100%)

Uncert: +/-0.159 +/-0.182 TPU: +/-0.156 +/-0.179 Silver-108m U -0.0028 U -0.0337 pCi/g N/A (0% - 100%)

Uncert: +/-0.0251 +/-0.0311 69

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 143553 Page 4 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Gamma Spec Batch 455561 TPU: +/-0.0246 +/-0.0304 Thallium-208 0.367 0.348 pCi/g 5 (0% - 100%)

Uncert: +/-0.0691 +/-0.0806 TPU: +/-0.0677 +/-0.079 QC1200918814 LCS Actinium-228 U 0.0895 pCi/g 09/02/05 10:32 Uncert: +/-0.788 TPU: +/-0.773 Americium-241 24.4 26.0 pCi/g 106 (75%-125%)

Uncert: +/-1.23 TPU: +/-1.21 Bismuth-212 U 0.0796 pCi/g Uncert: +/-1.64 TPU: +/-1.61 Bismuth-214 U 0.193 pCi/g Uncert: +/-0.389 TPU: +/-0.382 Cesium-134 U 0.0404 pCi/g Uncert: +/-0.221 TPU: +/-0.217 Cesium-137 9.41 9.86 pCi/g 105 (75%-125%)

Uncert: +/-0.731 TPU: +/-0.717 Cobalt-60 14.4 14.3 pCi/g 99 (75%-125%)

Uncert: +/-0.886 TPU: +/-0.869 Europium-152 U -0.0295 pCi/g Uncert: +/-0.441 TPU: +/-0.432 Europium-154 U 0.135 pCi/g Uncert: +/-0.512 TPU: +/-0.502 Europium-155 U -0.143 pCi/g Uncert: +/-0.480 TPU: +/-0.471 Lead-212 U 0.0912 pCi/g Uncert: +/-0.234 TPU: +/-0.229 Lead-214 U 0.0951 pCi/g Uncert: +/-0.308 TPU: +/-0.302 Manganese-54 U -0.181 pCi/g Uncert: +/-0.198 TPU: +/-0.194 Niobium-94 0.338 pCi/g Uncert: +/-0.247 TPU: +/-0.242 Potassium-40 U -0.755 pCi/g 70

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 143553 Page 5 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Gamma Spec Batch 455561 Uncert: +/-1.92 TPU: +/-1.88 Radium-226 U 0.193 pCi/g (75%-125%)

Uncert: +/-0.389 TPU: +/-0.382 Silver-108m U -0.000549 pCi/g Uncert: +/-0.164 TPU: +/-0.160 Thallium-208 U 0.150 pCi/g Uncert: +/-0.204 TPU: +/-0.200 QC1200918812 MB Actinium-228 U 0.0299 pCi/g 09/03/05 13:08 Uncert: +/-0.066 TPU: +/-0.0647 Americium-241 U -0.0291 pCi/g Uncert: +/-0.0908 TPU: +/-0.089 Bismuth-212 U 0.0216 pCi/g Uncert: +/-0.125 TPU: +/-0.122 Bismuth-214 U 0.0277 pCi/g Uncert: +/-0.0366 TPU: +/-0.0358 Cesium-134 U 0.00486 pCi/g Uncert: +/-0.0172 TPU: +/-0.0169 Cesium-137 U 0.00374 pCi/g Uncert: +/-0.0168 TPU: +/-0.0164 Cobalt-60 U 0.00814 pCi/g Uncert: +/-0.0185 TPU: +/-0.0182 Europium-152 U 0.00266 pCi/g Uncert: +/-0.0473 TPU: +/-0.0464 Europium-154 U 0.0119 pCi/g Uncert: +/-0.0506 TPU: +/-0.0496 Europium-155 U 0.0486 pCi/g Uncert: +/-0.0418 TPU: +/-0.041 Lead-212 U 0.00983 pCi/g Uncert: +/-0.0359 TPU: +/-0.0352 Lead-214 U -0.0132 pCi/g Uncert: +/-0.0317 TPU: +/-0.031 71

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 143553 Page 6 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Gamma Spec Batch 455561 Manganese-54 U 0.00485 pCi/g Uncert: +/-0.0148 TPU: +/-0.0145 Niobium-94 U 0.0198 pCi/g Uncert: +/-0.0456 TPU: +/-0.0447 Potassium-40 U 0.105 pCi/g Uncert: +/-0.213 TPU: +/-0.209 Radium-226 U 0.0277 pCi/g Uncert: +/-0.0366 TPU: +/-0.0358 Silver-108m U -0.00498 pCi/g Uncert: +/-0.0162 TPU: +/-0.0159 Thallium-208 U 0.0219 pCi/g Uncert: +/-0.0195 TPU: +/-0.0191 Rad Gas Flow Batch 457354 QC1200922922 144089001 DUP Strontium-90 U -0.00891 U 0.00489 pCi/g N/A (0% - 100%) EXW1 08/31/05 22:11 Uncert: +/-0.012 +/-0.0212 TPU: +/-0.012 +/-0.0212 QC1200922924 LCS Strontium-90 1.12 0.988 pCi/g 88 (75%-125%) 08/31/05 20:58 Uncert: +/-0.0734 TPU: +/-0.0834 QC1200922921 MB Strontium-90 U 0.00853 pCi/g 08/31/05 22:11 Uncert: +/-0.00989 TPU: +/-0.00996 QC1200922923 144089001 MS Strontium-90 2.56 U -0.00891 2.05 pCi/g 80 (75%-125%) 08/31/05 20:58 Uncert: +/-0.012 +/-0.221 TPU: +/-0.012 +/-0.233 Rad Liquid Scintillation Batch 455604 QC1200918897 143735017 DUP Technetium-99 U 0.190 U 0.108 pCi/g 0 (0% - 100%) BXF1 08/31/05 06:26 Uncert: +/-0.277 +/-0.264 TPU: +/-0.277 +/-0.264 QC1200918899 LCS Technetium-99 12.3 11.2 pCi/g 91 (75%-125%) 08/31/05 07:33 Uncert: +/-0.318 TPU: +/-0.417 QC1200918896 MB Technetium-99 U 0.0309 pCi/g 08/31/05 05:53 72

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 143553 Page 7 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Liquid Scintillation Batch 455604 Uncert: +/-0.123 TPU: +/-0.123 QC1200918898 143735017 MS Technetium-99 23.3 U 0.190 21.4 pCi/g 92 (75%-125%) 08/31/05 06:59 Uncert: +/-0.277 +/-0.619 TPU: +/-0.277 +/-0.810 Batch 455633 QC1200918969 143553017 DUP Tritium U 7.90 U 5.06 pCi/g 0 (0% - 100%) MXP1 09/03/05 07:52 Uncert: +/-8.19 +/-7.44 TPU: +/-8.19 +/-7.44 QC1200918971 LCS Tritium 25.4 20.7 pCi/g 82 (75%-125%) 09/02/05 04:25 Uncert: +/-2.66 TPU: +/-2.68 QC1200918968 MB Tritium U 1.16 pCi/g 09/02/05 02:49 Uncert: +/-1.90 TPU: +/-1.90 QC1200918970 143553017 MS Tritium 147 U 7.90 115 pCi/g 78 (75%-125%) 09/02/05 03:53 Uncert: +/-8.19 +/-15.3 TPU: +/-8.19 +/-15.4 Batch 457431 QC1200923110 144089001 DUP Iron-55 U -4.13 U -14 pCi/g N/A (0% - 100%) AF1 09/02/05 05:31 Uncert: +/-57.7 +/-49.6 TPU: +/-57.7 +/-49.6 QC1200923112 LCS Iron-55 72.8 68.5 pCi/g 94 (75%-125%) 09/02/05 06:05 Uncert: +/-6.45 TPU: +/-7.36 QC1200923109 MB Iron-55 U -2.36 pCi/g 09/02/05 01:42 Uncert: +/-1.56 TPU: +/-1.56 QC1200923111 144089001 MS Iron-55 834 U -4.13 724 pCi/g 87 (75%-125%) 09/02/05 05:48 Uncert: +/-57.7 +/-61.4 TPU: +/-57.7 +/-73.9 Batch 457432 QC1200923114 144089001 DUP Nickel-63 U -4.18 U 0.259 pCi/g N/A (0% - 100%) AF1 09/03/05 03:33 Uncert: +/-6.36 +/-6.51 TPU: +/-6.37 +/-6.51 QC1200923116 LCS Nickel-63 74.7 78.0 pCi/g 104 (75%-125%) 09/03/05 04:38 Uncert: +/-2.66 TPU: +/-5.14 73

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 143553 Page 8 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Liquid Scintillation Batch 457432 QC1200923113 MB Nickel-63 U 0.265 pCi/g 09/03/05 03:00 Uncert: +/-1.00 TPU: +/-1.00 QC1200923115 144089001 MS Nickel-63 475 U -4.18 480 pCi/g 101 (75%-125%) 09/03/05 04:05 Uncert: +/-6.36 +/-16.3 TPU: +/-6.37 +/-33.0 Batch 459955 QC1200929173 143553017 DUP Carbon-14 U 0.0671 U -0.0359 pCi/g N/A (0% - 100%) BXF1 09/15/05 08:50 Uncert: +/-0.0802 +/-0.0765 TPU: +/-0.0802 +/-0.0766 QC1200929175 LCS Carbon-14 7.22 6.51 pCi/g 90 (75%-125%) 09/15/05 11:42 Uncert: +/-0.172 TPU: +/-0.200 QC1200929172 MB Carbon-14 U -0.0717 pCi/g 09/15/05 07:16 Uncert: +/-0.0773 TPU: +/-0.0773 QC1200929174 143553017 MS Carbon-14 7.01 U 0.0671 5.92 pCi/g 84 (75%-125%) 09/17/05 00:11 Uncert: +/-0.0802 +/-0.242 TPU: +/-0.0802 +/-0.259 Notes:

The Qualifiers in this report are defined as follows:

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Lab-specific qualifier-please see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

74

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 143553 Page 9 of 9 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.

    • Indicates analyte is a surrogate compound.

^ The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

75

Page 2 of 34 Page 3 of 34 Page 4 of 34 Page 5 of 34 Page 6 of 34 Page 7 of 34 RADIOLOGICAL ANALYSIS Page 8 of 34

Radiochemistry Case Narrative Connecticut Yankee Atomic Power Co. (YANK)

SDG MSR#05-2390 Method/Analysis Information Product: Gamma,Solid-FSS GAM & ALL FSS 226 Ingrowth Waived Analytical Method: EML HASL 300, 4.5.2.3 Prep Method: Dry Soil Prep Analytical Batch Number: 470244 Prep Batch Number: 469742 Sample ID Client ID 147165001 9527-0004-2A 147165002 9527-0004-2B 147165003 9527-0004-2C 147165004 9527-0004-2D 147165005 9527-0004-3A 147165006 9527-0004-3B 147165007 9527-0004-3C 147165008 9527-0004-3D 1200953827 Method Blank (MB) 1200953828 147165001(9527-0004-2A) Sample Duplicate (DUP) 1200953829 Laboratory Control Sample (LCS)

SOP Reference Procedure for preparation, analysis and reporting of analytical data are controlled by General Engineering Laboratories, LLC as Standard Operating Procedure (SOP). The data discussed in this narrative has been analyzed in accordance with GL-RAD-A-013 REV# 10.

Calibration Information:

Calibration Information All initial and continuing calibration requirements have been met.

Standards Information Standard solution(s) for these analyses are NIST traceable and used before the expiration date(s).

Sample Geometry All counting sources were prepared in the same geometry as the calibration standards.

Quality Control (QC) Information:

Blank Information The blank volume is representative of the sample volume in this batch.

Designated QC The following sample was used for QC: 147165001 (9527-0004-2A).

QC Information All of the QC samples met the required acceptance limits.

Technical Information:

Holding Time Page 9 of 34

All sample procedures for this sample set were performed within the required holding time.

Preparation Information All preparation criteria have been met for these analyses.

Sample Re-prep/Re-analysis None of the samples in this sample set required reprep or reanalysis.

Miscellaneous Information:

NCR Documentation Nonconformance reports are generated to document any procedural anomalies that may deviate from referenced SOP or contractual documents. An NCR was not generated for this SDG.

Additional Comments The relative percent difference for K-40 did not meet the duplication criteria. However, when a relative error ratio is calculated, precision is shown at 2.31687.

Qualifier information Qualifier Reason Analyte Sample UI Data rejected due to low abundance. Actinium-228 147165003 Cesium-134 147165006 147165008 Cobalt-60 147165001 147165002 Thallium-208 147165001 UI Data rejected due to no valid peak. Actinium-228 147165001 Cobalt-60 147165003 Potassium-40 1200953827 Certification Statement Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless otherwise noted in the analytical case narrative.

Review Validation:

GEL requires all analytical data to be verified by a qualified data validator. In addition, all data designated for CLP or CLP-like packaging will receive a third level validation upon completion of the data package.

The following data validator verified the information presented in this case narrative:

Reviewer:________________________________________________________________

Page 10 of 34

SAMPLE DATA

SUMMARY

Page 11 of 34

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com Certificate of Analysis Report for YANK001 Connecticut Yankee Atomic Power Co.

Client SDG: MSR#05-2390 GEL Work Order: 147165 The Qualifiers in this report are defined as follows:

    • Indicates the analyte is a surrogate compound.

< Result is less than amount reported.

> Result is greater than amount reported.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

P The response between the confirmation and the primary columns is >40% Different.

R Sample results are rejected.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Lab-specific qualifier-please see case narrative, data summary package or contact your project manager for details.

Y QC Samples were not spiked with this compound.

Z Paint Filter qualifier: Particulates passed through the filter. No free liquids were observed.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the Certificate of Analysis.

    • Indicates the analyte is a surrogate compound.

This data report has been prepared and reviewed in accordance with General Engineering Laboratories, LLC standard operating procedures. Please direct any questions to your Project Manager, Cheryl Jones.

Reviewed by Page 12 of 34

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: October 12, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 952700042A Project: YANK01204 Sample ID: 147165001 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 04OCT05 Receive Date: 06OCT05 Collector: Client Moisture: 67.3%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Rad Gamma Spec Analysis Gamma,SolidFSS GAM & ALL FSS 226 Ingrowth Waived Actinium228 UUI 0.00 +/0.237 0.0766 +/0.233 0.160 pCi/g MJH1 10/09/05 1922 470244 1 Americium241 U 0.0805 +/0.173 0.119 +/0.170 0.243 pCi/g Bismuth212 U 0.0978 +/0.505 0.163 +/0.495 0.338 pCi/g Bismuth214 0.438 +/0.125 0.0479 +/0.122 0.0986 pCi/g Cesium134 U 0.0447 +/0.0294 0.0251 +/0.0288 0.052 pCi/g Cesium137 3.72 +/0.114 0.0236 +/0.112 0.0488 pCi/g Cobalt60 UUI 0.00 +/0.033 0.0286 +/0.0323 0.0596 pCi/g Europium152 U 0.0152 +/0.0843 0.0655 +/0.0826 0.134 pCi/g Europium154 U 0.0227 +/0.082 0.0651 +/0.0804 0.137 pCi/g Europium155 U 0.0781 +/0.0897 0.0685 +/0.0879 0.140 pCi/g Lead212 0.273 +/0.0803 0.0394 +/0.0787 0.0804 pCi/g Lead214 0.574 +/0.168 0.0463 +/0.165 0.0951 pCi/g Manganese54 U 0.00154 +/0.0322 0.0224 +/0.0316 0.0465 pCi/g Niobium94 U 0.0196 +/0.0281 0.022 +/0.0276 0.0455 pCi/g Potassium40 3.92 +/0.849 0.239 +/0.832 0.503 pCi/g Radium226 0.438 +/0.125 0.0479 +/0.122 0.0986 pCi/g Silver108m U 0.00301 +/0.0303 0.0236 +/0.0297 0.0484 pCi/g Thallium208 UUI 0.00 +/0.0613 0.032 +/0.060 0.0655 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GLRADA021 TC1 10/06/05 1121 469742 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows :

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

Page 13 of 34

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: October 12, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 952700042A Project: YANK01204 Sample ID: 147165001 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M BD Results below the MDC or low tracer recovery.

E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

The above sample is reported on a dry weight basis.

Page 14 of 34

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: October 12, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 952700042B Project: YANK01204 Sample ID: 147165002 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 04OCT05 Receive Date: 06OCT05 Collector: Client Moisture: 61.6%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Rad Gamma Spec Analysis Gamma,SolidFSS GAM & ALL FSS 226 Ingrowth Waived Actinium228 0.417 +/0.320 0.0987 +/0.313 0.206 pCi/g MJH1 10/09/05 1922 470244 1 Americium241 U 0.0461 +/0.123 0.0897 +/0.120 0.183 pCi/g Bismuth212 U 0.354 +/0.292 0.236 +/0.286 0.488 pCi/g Bismuth214 0.557 +/0.184 0.0544 +/0.180 0.112 pCi/g Cesium134 U 0.0208 +/0.0392 0.0309 +/0.0384 0.0644 pCi/g Cesium137 3.25 +/0.349 0.0284 +/0.342 0.0589 pCi/g Cobalt60 UUI 0.00 +/0.0397 0.0346 +/0.0389 0.0724 pCi/g Europium152 U 0.103 +/0.106 0.0819 +/0.104 0.168 pCi/g Europium154 U 0.0074 +/0.105 0.0822 +/0.103 0.173 pCi/g Europium155 U 0.00722 +/0.107 0.077 +/0.104 0.157 pCi/g Lead212 0.304 +/0.119 0.0419 +/0.116 0.0858 pCi/g Lead214 0.939 +/0.210 0.0559 +/0.206 0.115 pCi/g Manganese54 U 0.00553 +/0.0382 0.0295 +/0.0374 0.0612 pCi/g Niobium94 U 0.0185 +/0.0364 0.0287 +/0.0357 0.0593 pCi/g Potassium40 3.83 +/1.01 0.296 +/0.994 0.624 pCi/g Radium226 0.557 +/0.184 0.0544 +/0.180 0.112 pCi/g Silver108m U 0.0238 +/0.0382 0.0278 +/0.0375 0.0573 pCi/g Thallium208 0.0903 +/0.0799 0.0267 +/0.0783 0.0553 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GLRADA021 TC1 10/06/05 1121 469742 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows :

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

Page 15 of 34

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: October 12, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 952700042B Project: YANK01204 Sample ID: 147165002 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M BD Results below the MDC or low tracer recovery.

E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

The above sample is reported on a dry weight basis.

Page 16 of 34

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: October 12, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 952700042C Project: YANK01204 Sample ID: 147165003 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 04OCT05 Receive Date: 06OCT05 Collector: Client Moisture: 42.9%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Rad Gamma Spec Analysis Gamma,SolidFSS GAM & ALL FSS 226 Ingrowth Waived Actinium228 UUI 0.00 +/0.314 0.176 +/0.308 0.365 pCi/g MJH1 10/09/05 1923 470244 1 Americium241 U 0.0867 +/0.0741 0.043 +/0.0727 0.0875 pCi/g Bismuth212 U 0.016 +/0.606 0.268 +/0.594 0.559 pCi/g Bismuth214 1.05 +/0.210 0.0746 +/0.206 0.154 pCi/g Cesium134 U 0.028 +/0.0485 0.0384 +/0.0476 0.0803 pCi/g Cesium137 5.53 +/0.447 0.0374 +/0.438 0.0778 pCi/g Cobalt60 UUI 0.00 +/0.103 0.0302 +/0.101 0.0651 pCi/g Europium152 U 0.0542 +/0.127 0.0967 +/0.125 0.199 pCi/g Europium154 U 0.0408 +/0.123 0.100 +/0.121 0.214 pCi/g Europium155 U 0.0552 +/0.106 0.0774 +/0.104 0.158 pCi/g Lead212 0.530 +/0.131 0.058 +/0.128 0.118 pCi/g Lead214 1.30 +/0.215 0.0705 +/0.210 0.145 pCi/g Manganese54 U 0.0267 +/0.0408 0.0314 +/0.040 0.066 pCi/g Niobium94 U 0.0136 +/0.0438 0.0331 +/0.043 0.0688 pCi/g Potassium40 7.28 +/1.17 0.311 +/1.15 0.669 pCi/g Radium226 1.05 +/0.210 0.0746 +/0.206 0.154 pCi/g Silver108m U 0.0101 +/0.0495 0.0384 +/0.0485 0.0788 pCi/g Thallium208 0.260 +/0.0874 0.035 +/0.0857 0.0727 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GLRADA021 TC1 10/06/05 1121 469742 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows :

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

Page 17 of 34

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: October 12, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 952700042C Project: YANK01204 Sample ID: 147165003 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M BD Results below the MDC or low tracer recovery.

E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

The above sample is reported on a dry weight basis.

Page 18 of 34

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: October 12, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 952700042D Project: YANK01204 Sample ID: 147165004 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 04OCT05 Receive Date: 06OCT05 Collector: Client Moisture: 46.1%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Rad Gamma Spec Analysis Gamma,SolidFSS GAM & ALL FSS 226 Ingrowth Waived Actinium228 0.367 +/0.177 0.0658 +/0.173 0.139 pCi/g MJH1 10/10/05 2006 470244 1 Americium241 U 0.0119 +/0.109 0.0727 +/0.107 0.149 pCi/g Bismuth212 0.434 +/0.299 0.152 +/0.293 0.319 pCi/g Bismuth214 0.541 +/0.131 0.0387 +/0.128 0.0804 pCi/g Cesium134 U 0.0233 +/0.0273 0.0219 +/0.0268 0.046 pCi/g Cesium137 3.41 +/0.286 0.0226 +/0.280 0.0469 pCi/g Cobalt60 U 0.0346 +/0.0282 0.0245 +/0.0276 0.052 pCi/g Europium152 U 0.0181 +/0.0757 0.060 +/0.0741 0.123 pCi/g Europium154 U 0.000192 +/0.0738 0.0589 +/0.0724 0.126 pCi/g Europium155 U 0.0192 +/0.0712 0.0532 +/0.0698 0.109 pCi/g Lead212 0.344 +/0.0694 0.0362 +/0.068 0.074 pCi/g Lead214 0.807 +/0.145 0.0426 +/0.142 0.0877 pCi/g Manganese54 U 0.00818 +/0.0259 0.0203 +/0.0254 0.0425 pCi/g Niobium94 U 0.013 +/0.0228 0.017 +/0.0223 0.0355 pCi/g Potassium40 4.85 +/0.809 0.187 +/0.792 0.404 pCi/g Radium226 0.541 +/0.131 0.0387 +/0.128 0.0804 pCi/g Silver108m U 0.0295 +/0.0247 0.0206 +/0.0243 0.0426 pCi/g Thallium208 0.0973 +/0.0619 0.0196 +/0.0607 0.0408 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GLRADA021 TC1 10/06/05 1121 469742 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows :

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

Page 19 of 34

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: October 12, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 952700042D Project: YANK01204 Sample ID: 147165004 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M BD Results below the MDC or low tracer recovery.

E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

The above sample is reported on a dry weight basis.

Page 20 of 34

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: October 12, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 952700043A Project: YANK01204 Sample ID: 147165005 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 04OCT05 Receive Date: 06OCT05 Collector: Client Moisture: 25.9%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Rad Gamma Spec Analysis Gamma,SolidFSS GAM & ALL FSS 226 Ingrowth Waived Actinium228 0.801 +/0.292 0.0869 +/0.286 0.183 pCi/g MJH1 10/10/05 2007 470244 1 Americium241 U 0.0431 +/0.0385 0.0291 +/0.0377 0.0595 pCi/g Bismuth212 0.626 +/0.445 0.188 +/0.436 0.393 pCi/g Bismuth214 1.03 +/0.176 0.0438 +/0.173 0.0914 pCi/g Cesium134 U 0.047 +/0.0541 0.029 +/0.053 0.0606 pCi/g Cesium137 2.83 +/0.249 0.0274 +/0.244 0.0569 pCi/g Cobalt60 U 0.0112 +/0.0327 0.0276 +/0.0321 0.0588 pCi/g Europium152 U 0.0147 +/0.0756 0.0582 +/0.0741 0.120 pCi/g Europium154 U 0.0497 +/0.104 0.0842 +/0.102 0.178 pCi/g Europium155 U 0.0574 +/0.0987 0.0435 +/0.0967 0.0892 pCi/g Lead212 0.829 +/0.101 0.0334 +/0.0989 0.0685 pCi/g Lead214 1.14 +/0.170 0.0434 +/0.167 0.0895 pCi/g Manganese54 U 0.0143 +/0.0322 0.0251 +/0.0316 0.0525 pCi/g Niobium94 U 0.0302 +/0.028 0.0237 +/0.0274 0.0493 pCi/g Potassium40 9.90 +/1.24 0.264 +/1.21 0.565 pCi/g Radium226 1.03 +/0.176 0.0438 +/0.173 0.0914 pCi/g Silver108m U 0.0169 +/0.0286 0.0214 +/0.028 0.0442 pCi/g Thallium208 0.289 +/0.0759 0.0243 +/0.0744 0.0505 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GLRADA021 TC1 10/06/05 1121 469742 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows :

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

Page 21 of 34

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: October 12, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 952700043A Project: YANK01204 Sample ID: 147165005 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M BD Results below the MDC or low tracer recovery.

E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

The above sample is reported on a dry weight basis.

Page 22 of 34

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: October 12, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 952700043B Project: YANK01204 Sample ID: 147165006 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 04OCT05 Receive Date: 06OCT05 Collector: Client Moisture: 29.5%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Rad Gamma Spec Analysis Gamma,SolidFSS GAM & ALL FSS 226 Ingrowth Waived Actinium228 0.666 +/0.187 0.0617 +/0.183 0.131 pCi/g MJH1 10/09/05 2145 470244 1 Americium241 U 0.00122 +/0.101 0.0734 +/0.0994 0.151 pCi/g Bismuth212 0.436 +/0.242 0.130 +/0.237 0.275 pCi/g Bismuth214 0.894 +/0.140 0.0381 +/0.137 0.0794 pCi/g Cesium134 UUI 0.00 +/0.0404 0.0228 +/0.0396 0.0479 pCi/g Cesium137 3.90 +/0.121 0.020 +/0.119 0.0418 pCi/g Cobalt60 U 0.0513 +/0.034 0.0248 +/0.0333 0.0526 pCi/g Europium152 U 0.0516 +/0.0718 0.0559 +/0.0704 0.115 pCi/g Europium154 U 0.0382 +/0.0826 0.0645 +/0.0809 0.138 pCi/g Europium155 U 0.0285 +/0.0615 0.0492 +/0.0603 0.101 pCi/g Lead212 0.689 +/0.0753 0.0282 +/0.0738 0.058 pCi/g Lead214 0.942 +/0.128 0.0419 +/0.125 0.0863 pCi/g Manganese54 U 0.0243 +/0.0399 0.0195 +/0.0391 0.0411 pCi/g Niobium94 U 0.0251 +/0.0217 0.0187 +/0.0212 0.0391 pCi/g Potassium40 10.5 +/0.918 0.196 +/0.900 0.424 pCi/g Radium226 0.894 +/0.140 0.0381 +/0.137 0.0794 pCi/g Silver108m U 0.00543 +/0.0267 0.0209 +/0.0262 0.0432 pCi/g Thallium208 0.212 +/0.0582 0.0181 +/0.057 0.038 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GLRADA021 TC1 10/06/05 1121 469742 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows :

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

Page 23 of 34

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: October 12, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 952700043B Project: YANK01204 Sample ID: 147165006 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M BD Results below the MDC or low tracer recovery.

E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

The above sample is reported on a dry weight basis.

Page 24 of 34

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: October 12, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 952700043C Project: YANK01204 Sample ID: 147165007 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 04OCT05 Receive Date: 06OCT05 Collector: Client Moisture: 40%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Rad Gamma Spec Analysis Gamma,SolidFSS GAM & ALL FSS 226 Ingrowth Waived Actinium228 0.514 +/0.217 0.0693 +/0.212 0.146 pCi/g MJH1 10/10/05 2027 470244 1 Americium241 U 0.0276 +/0.104 0.0777 +/0.102 0.159 pCi/g Bismuth212 U 0.260 +/0.336 0.160 +/0.329 0.335 pCi/g Bismuth214 0.773 +/0.132 0.0411 +/0.130 0.0852 pCi/g Cesium134 U 0.0475 +/0.0414 0.0234 +/0.0405 0.049 pCi/g Cesium137 3.83 +/0.284 0.0224 +/0.278 0.0465 pCi/g Cobalt60 0.0692 +/0.0372 0.0223 +/0.0365 0.0474 pCi/g Europium152 U 0.00547 +/0.078 0.060 +/0.0765 0.123 pCi/g Europium154 U 0.0413 +/0.0971 0.0634 +/0.0951 0.135 pCi/g Europium155 U 0.016 +/0.0728 0.0544 +/0.0713 0.111 pCi/g Lead212 0.518 +/0.0875 0.0306 +/0.0857 0.0626 pCi/g Lead214 0.997 +/0.172 0.0416 +/0.169 0.0855 pCi/g Manganese54 U 0.0227 +/0.0267 0.0198 +/0.0261 0.0414 pCi/g Niobium94 U 0.0127 +/0.024 0.0194 +/0.0235 0.0404 pCi/g Potassium40 7.22 +/1.15 0.206 +/1.13 0.441 pCi/g Radium226 0.773 +/0.132 0.0411 +/0.130 0.0852 pCi/g Silver108m U 0.00941 +/0.0289 0.0223 +/0.0283 0.0459 pCi/g Thallium208 0.118 +/0.0558 0.0206 +/0.0547 0.0428 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GLRADA021 TC1 10/06/05 1121 469742 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows :

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

Page 25 of 34

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: October 12, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 952700043C Project: YANK01204 Sample ID: 147165007 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M BD Results below the MDC or low tracer recovery.

E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

The above sample is reported on a dry weight basis.

Page 26 of 34

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: October 12, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 952700043D Project: YANK01204 Sample ID: 147165008 Client ID: YANK001 Matrix: TS Vol. Recv.:

Collect Date: 04OCT05 Receive Date: 06OCT05 Collector: Client Moisture: 14.7%

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M Rad Gamma Spec Analysis Gamma,SolidFSS GAM & ALL FSS 226 Ingrowth Waived Actinium228 0.908 +/0.236 0.0656 +/0.231 0.140 pCi/g MJH1 10/10/05 1121 470244 1 Americium241 U 0.0955 +/0.102 0.0755 +/0.0995 0.155 pCi/g Bismuth212 0.560 +/0.273 0.120 +/0.268 0.256 pCi/g Bismuth214 0.923 +/0.145 0.0325 +/0.142 0.0686 pCi/g Cesium134 UUI 0.00 +/0.0318 0.0223 +/0.0312 0.047 pCi/g Cesium137 1.40 +/0.130 0.0176 +/0.128 0.0373 pCi/g Cobalt60 U 0.00324 +/0.0247 0.0197 +/0.0242 0.0427 pCi/g Europium152 U 0.0188 +/0.0645 0.0521 +/0.0632 0.108 pCi/g Europium154 U 0.0176 +/0.0661 0.0521 +/0.0648 0.113 pCi/g Europium155 U 0.00472 +/0.0657 0.0522 +/0.0643 0.107 pCi/g Lead212 0.801 +/0.094 0.0339 +/0.0922 0.0695 pCi/g Lead214 1.21 +/0.153 0.0389 +/0.150 0.0807 pCi/g Manganese54 U 0.0315 +/0.0247 0.0178 +/0.0242 0.0378 pCi/g Niobium94 U 0.0253 +/0.0288 0.018 +/0.0282 0.0379 pCi/g Potassium40 10.2 +/1.18 0.185 +/1.16 0.402 pCi/g Radium226 0.923 +/0.145 0.0325 +/0.142 0.0686 pCi/g Silver108m U 0.0105 +/0.0223 0.0185 +/0.0218 0.0385 pCi/g Thallium208 0.248 +/0.0624 0.0184 +/0.0611 0.0387 pCi/g The following Prep Methods were performed Method Description Analyst Date Time Prep Batch Dry Soil Prep Dry Soil Prep GLRADA021 TC1 10/06/05 1121 469742 The following Analytical Methods were performed Method Description 1 EML HASL 300, 4.5.2.3 Notes:

The Qualifiers in this report are defined as follows :

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

Page 27 of 34

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 (843) 5568171 www.gel.com Certificate of Analysis Company : Connecticut Yankee Atomic Power Address : Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut 06424 Report Date: October 12, 2005

Contact:

Mr. Pete Hollenbeck Project: Soils PO# 002332 Client Sample ID: 952700043D Project: YANK01204 Sample ID: 147165008 Client ID: YANK001 Vol. Recv.:

Parameter Qualifier Result Uncertainty LC TPU MDA Units DF AnalystDate Time Batch M BD Results below the MDC or low tracer recovery.

E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Labspecific qualifierplease see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

The above sample is reported on a dry weight basis.

Page 28 of 34

QUALITY CONTROL DATA Page 29 of 34

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Report Date: October 12, 2005 Client : Connecticut Yankee Atomic Power Page 1 of 5 Haddam Neck Plant 362 Injun Hollow Road East Hampton, Connecticut

Contact:

Mr. Pete Hollenbeck Workorder: 147165 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Gamma Spec Batch 470244 QC1200953828 147165001 DUP Actinium-228 UUI 0.00 U 0.0742 pCi/g 73 (0% - 100%) MJH1 10/10/05 20:28 Uncert: +/-0.237 +/-0.412 TPU: +/-0.233 +/-0.403 Americium-241 U 0.0805 U 0.0828 pCi/g 34 (0% - 100%)

Uncert: +/-0.173 +/-0.0886 TPU: +/-0.170 +/-0.0868 Bismuth-212 U 0.0978 U 0.384 pCi/g 78 (0% - 100%)

Uncert: +/-0.505 +/-0.583 TPU: +/-0.495 +/-0.571 Bismuth-214 0.438 0.801 pCi/g 82 * (0% - 100%)

Uncert: +/-0.125 +/-0.260 TPU: +/-0.122 +/-0.255 Cesium-134 U 0.0447 U 0.00468 pCi/g 166 (0% - 100%)

Uncert: +/-0.0294 +/-0.0691 TPU: +/-0.0288 +/-0.0678 Cesium-137 3.72 3.70 pCi/g 1 (0% - 20%)

Uncert: +/-0.114 +/-0.369 TPU: +/-0.112 +/-0.362 Cobalt-60 UUI 0.00 U 0.0283 pCi/g 72 (0% - 100%)

Uncert: +/-0.033 +/-0.0671 TPU: +/-0.0323 +/-0.0658 Europium-152 U -0.0152 U 0.037 pCi/g N/A (0% - 100%)

Uncert: +/-0.0843 +/-0.180 TPU: +/-0.0826 +/-0.177 Europium-154 U 0.0227 U -0.0232 pCi/g N/A (0% - 100%)

Uncert: +/-0.082 +/-0.186 TPU: +/-0.0804 +/-0.182 Europium-155 U 0.0781 U 0.00707 pCi/g 165 (0% - 100%)

Uncert: +/-0.0897 +/-0.129 TPU: +/-0.0879 +/-0.126 Lead-212 0.273 0.232 pCi/g 20 (0% - 100%)

Uncert: +/-0.0803 +/-0.156 TPU: +/-0.0787 +/-0.152 Lead-214 0.574 0.701 pCi/g 14 (0% - 20%)

Uncert: +/-0.168 +/-0.241 TPU: +/-0.165 +/-0.236 Manganese-54 U 0.00154 U 0.0133 pCi/g 229 (0% - 100%)

Uncert: +/-0.0322 +/-0.0621 TPU: +/-0.0316 +/-0.0609 Niobium-94 U 0.0196 U 0.0286 pCi/g 8 (0% - 100%)

Uncert: +/-0.0281 +/-0.0579 TPU: +/-0.0276 +/-0.0568 Page 30 of 34

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 147165 Page 2 of 5 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Gamma Spec Batch 470244 Potassium-40 3.92 5.53 pCi/g 37 * (0%-20%)

Uncert: +/-0.849 +/-1.27 TPU: +/-0.832 +/-1.24 Radium-226 0.438 0.801 pCi/g 82 (0% - 100%)

Uncert: +/-0.125 +/-0.260 TPU: +/-0.122 +/-0.255 Silver-108m U 0.00301 U 0.049 pCi/g 91 (0% - 100%)

Uncert: +/-0.0303 +/-0.0609 TPU: +/-0.0297 +/-0.0597 Thallium-208 UUI 0.00 0.149 pCi/g 42 * (0% - 100%)

Uncert: +/-0.0613 +/-0.145 TPU: +/-0.060 +/-0.142 QC1200953829 LCS Actinium-228 U 0.498 pCi/g 10/09/05 21:45 Uncert: +/-0.729 TPU: +/-0.715 Americium-241 24.4 25.0 pCi/g 102 (75%-125%)

Uncert: +/-1.13 TPU: +/-1.11 Bismuth-212 U 0.463 pCi/g Uncert: +/-1.61 TPU: +/-1.58 Bismuth-214 U -0.0651 pCi/g Uncert: +/-0.363 TPU: +/-0.356 Cesium-134 U -0.0986 pCi/g Uncert: +/-0.246 TPU: +/-0.241 Cesium-137 9.38 10.3 pCi/g 110 (75%-125%)

Uncert: +/-0.697 TPU: +/-0.683 Cobalt-60 14.2 15.1 pCi/g 106 (75%-125%)

Uncert: +/-0.852 TPU: +/-0.835 Europium-152 U -0.248 pCi/g Uncert: +/-0.422 TPU: +/-0.414 Europium-154 U -0.448 pCi/g Uncert: +/-0.435 TPU: +/-0.426 Europium-155 U 0.256 pCi/g Uncert: +/-0.451 TPU: +/-0.442 Lead-212 U -0.152 pCi/g Uncert: +/-0.220 TPU: +/-0.215 Lead-214 U -0.196 pCi/g Uncert: +/-0.306 Page 31 of 34

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 147165 Page 3 of 5 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Gamma Spec Batch 470244 TPU: +/-0.300 Manganese-54 U 0.010 pCi/g Uncert: +/-0.198 TPU: +/-0.194 Niobium-94 U -0.18 pCi/g Uncert: +/-0.192 TPU: +/-0.188 Potassium-40 U 1.01 pCi/g Uncert: +/-1.78 TPU: +/-1.75 Radium-226 U -0.0651 pCi/g (75%-125%)

Uncert: +/-0.363 TPU: +/-0.356 Silver-108m U 0.0669 pCi/g Uncert: +/-0.166 TPU: +/-0.163 Thallium-208 U -0.179 pCi/g Uncert: +/-0.192 TPU: +/-0.188 QC1200953827 MB Actinium-228 U 0.121 pCi/g 10/10/05 11:22 Uncert: +/-0.175 TPU: +/-0.172 Americium-241 U 0.013 pCi/g Uncert: +/-0.0429 TPU: +/-0.042 Bismuth-212 U 0.116 pCi/g Uncert: +/-0.322 TPU: +/-0.315 Bismuth-214 U 0.0808 pCi/g Uncert: +/-0.135 TPU: +/-0.132 Cesium-134 U -0.00238 pCi/g Uncert: +/-0.0464 TPU: +/-0.0454 Cesium-137 U 0.0519 pCi/g Uncert: +/-0.0407 TPU: +/-0.0399 Cobalt-60 U 0.00406 pCi/g Uncert: +/-0.0391 TPU: +/-0.0383 Europium-152 U -0.068 pCi/g Uncert: +/-0.0966 TPU: +/-0.0947 Europium-154 U 0.0271 pCi/g Uncert: +/-0.124 TPU: +/-0.122 Europium-155 U 0.0258 pCi/g Page 32 of 34

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 147165 Page 4 of 5 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time Rad Gamma Spec Batch 470244 Uncert: +/-0.0793 TPU: +/-0.0778 Lead-212 U 0.0604 pCi/g Uncert: +/-0.0873 TPU: +/-0.0856 Lead-214 U 0.0197 pCi/g Uncert: +/-0.123 TPU: +/-0.121 Manganese-54 U 0.00187 pCi/g Uncert: +/-0.0377 TPU: +/-0.0369 Niobium-94 U 0.0209 pCi/g Uncert: +/-0.0366 TPU: +/-0.0358 Potassium-40 UUI 0.00 pCi/g Uncert: +/-0.989 TPU: +/-0.969 Radium-226 U 0.0808 pCi/g Uncert: +/-0.135 TPU: +/-0.132 Silver-108m U -0.0155 pCi/g Uncert: +/-0.0354 TPU: +/-0.0346 Thallium-208 U 0.0605 pCi/g Uncert: +/-0.0414 TPU: +/-0.0406 Notes:

The Qualifiers in this report are defined as follows:

    • Indicates the analyte is a surrogate compound.

B Target analyte was detected in the sample as well as the associated blank.

BD Results below the MDC or low tracer recovery.

E Concentration of the target analyte exceeds the instrument calibration range.

H Analytical holding time exceeded.

J Indicates an estimated value.

U Target analyte was analyzed for but not detected above the MDL or LOD.

UI Uncertain identification for gamma spectroscopy.

X Lab-specific qualifier-please see case narrative, data summary package or contact your project manager for details.

d The 2:1 depletion requirement was not met for this sample h Sample preparation or preservation holding time exceeded.

Page 33 of 34

GENERAL ENGINEERING LABORATORIES, LLC 2040 Savage Road Charleston SC 29407 - (843) 556-8171 - www.gel.com QC Summary Workorder: 147165 Page 5 of 5 Parmname NOM Sample Qual QC Units RPD% REC% Range Anlst Date Time N/A indicates that spike recovery limits do not apply when sample concentration exceeds spike conc. by a factor of 4 or more.

    • Indicates analyte is a surrogate compound.

^ The Relative Percent Difference (RPD) obtained from the sample duplicate (DUP) is evaluated against the acceptence criteria when the sample is greater than five times (5X) the contract required detection limit (RL). In cases where either the sample or duplicate value is less than 5X the RL, a control limit of +/- the RL is used to evaluate the DUP result.

For PS, PSD, and SDILT results, the values listed are the measured amounts, not final concentrations.

Where the analytical method has been performed under NELAP certification, the analysis has met all of the requirements of the NELAC standard unless qualified on the QC Summary.

Page 34 of 34

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0004 RELEASE RECORD Attachment 2b Sample and Scan Area Data (7 Pages)

Survey Release Record Scan Area Results Survey Unit 9527-0004 SAMPLE LOCATION SCANS 9527-0004 Backgound Action Level Results Above Sample Name (cpm) (cpm) (cpm) AL Log Date Log Time E600 S/N Probe S/N 9527-04-SL-00-01-0 12000 13563 12900 08/10/2005 1:11 PM 1105 1006 9527-04-SL-00-02-0 17100 18966 17700 08/10/2005 1:19 PM 1107 1010 9527-04-ER-00-03-0 20000 22018 25700 + 08/10/2005 1:23 PM 1105 1006 9527-04-SL-00-04-0 9830 11245 9220 08/10/2005 1:31 PM 1105 1006 9527-04-SL-00-05-0 8560 9880 8840 08/10/2005 1:41 PM 1107 1010 9527-04-SL-00-06-0 10900 12390 12400 + 08/10/2005 2:18 PM 1105 1006 9527-04-ER-00-06-0 10900 12390 11900 08/10/2005 2:20 PM 1105 1006 9527-04-ER-00-07-0 11100 12604 19400 + 08/10/2005 2:13 PM 1107 1010 9527-04-SL-00-08-0 9910 11331 12100 + 08/10/2005 2:03 PM 1105 1006 9527-04-SL-00-09-0 7570 8812 8650 08/10/2005 1:57 PM 1107 1010 9527-04-SL-00-10-0 5320 6361 5640 08/10/2005 1:48 PM 1105 1006 9527-04-SL-00-11-0 8390 9697 7950 08/10/2005 2:48 PM 1107 1010 9527-04-SL-00-12-0 10400 11855 10900 08/10/2005 2:52 PM 1105 1006 9527-04-SL-00-13-0 8280 9579 7750 08/10/2005 3:01 PM 1107 1010 9527-04-SL-00-14-0 9530 10923 8950 08/10/2005 3:04 PM 1105 1006 9527-04-SL-00-15-0 7650 8898 7260 08/10/2005 3:11 PM 1107 1010 9527-04-SL-00-16-0 13100 14733 12700 08/17/2005 9:02 AM 1112 1010 9527-04-SL-00-17-0 11800 13350 13200 08/17/2005 8:57 AM 1112 1010 AL - Action Level

Survey Release Record Scan Area Results Survey Unit 9527-0004 9527-0004 SCAN AREA 1 SECTIONS 1 THROUGH 5 Backgound Action Level Results Above Sample Name (cpm) (cpm) (cpm) AL Log Date Log Time E600 S/N Probe S/N 9527-04-SC-01-01-0 10700 12176 10700 08/11/2005 9:53 AM 1109 1007 9527-04-SC-01-02-0 10700 12176 10200 08/11/2005 10:04 AM 1109 1007 9527-04-SC-01-03-0 9940 11363 11000 08/11/2005 10:09 AM 1109 1007 9527-04-SC-01-04-0 10000 11427 9920 08/11/2005 10:12 AM 1109 1007 9527-04-SC-01-05-0 10200 11641 12100 + 08/11/2005 10:16 AM 1109 1007 9527-04-SC-01-06-0 10900 12390 10500 08/11/2005 10:19 AM 1109 1007 9527-04-SC-01-07-0 12100 13670 10600 08/11/2005 10:23 AM 1109 1007 9527-04-SC-01-08-0 10500 11962 10900 08/11/2005 10:27 AM 1109 1007 9527-04-SC-01-09-0 11000 12497 11400 08/11/2005 10:57 AM 1109 1007 9527-04-SC-01-10-0 10700 12176 8810 08/11/2005 10:59 AM 1109 1007 9527-04-SC-01-11-0 14300 16007 14600 08/11/2005 11:01 AM 1109 1007 9527-04-SC-01-12-0 15400 17171 11600 08/11/2005 11:04 AM 1109 1007 9527-04-SC-01-13-0 11800 13350 16300 + 08/11/2005 11:16 AM 1109 1007 9527-04-ER-01-13-1 11800 13350 15600 + 08/11/2005 11:15 AM 1109 1007 9527-04-ER-01-13-2 11800 13350 32200 + 08/11/2005 11:15 AM 1109 1007 9527-04-SC-01-14-0 16000 17805 15000 08/11/2005 11:21 AM 1109 1007 9527-04-SC-01-15-0 13300 14946 15000 + 08/11/2005 11:23 AM 1109 1007 9527-04-SC-01-16-0 11100 12604 11100 08/11/2005 11:28 AM 1109 1007 9527-04-SC-01-17-0 9960 11384 11200 08/16/2005 2:01 PM 1105 1006 9527-04-SC-01-18-0 10300 11748 9550 08/16/2005 2:03 PM 1105 1006 9527-04-SC-01-19-0 9120 10483 9710 08/16/2005 2:05 PM 1105 1006 9527-04-SC-01-20-0 9480 10870 9370 08/16/2005 2:09 PM 1105 1006 9527-04-SC-01-21-0 11800 13350 9710 08/16/2005 2:11 PM 1105 1006 9527-04-SC-01-22-0 16000 17805 10000 08/16/2005 2:13 PM 1105 1006 9527-04-SC-01-23-0 11000 12497 10800 08/16/2005 2:15 PM 1105 1006 9527-04-SC-01-24-0 10600 12069 10200 08/16/2005 2:16 PM 1105 1006 9527-04-SC-01-25-0 9970 11395 7150 08/11/2005 2:14 PM 1107 1010 9527-04-SC-01-26-0 8480 9794 9230 08/11/2005 2:19 PM 1107 1010 9527-04-SC-01-27-0 11900 13457 12400 08/11/2005 2:24 PM 1107 1010 9527-04-SC-01-28-0 11000 12497 8040 08/11/2005 2:28 PM 1107 1010 9527-04-SC-01-29-0 12000 13563 11900 08/11/2005 2:34 PM 1107 1010 9527-04-SC-01-30-0 10800 12283 11000 08/11/2005 2:37 PM 1107 1010 9527-04-SC-01-31-0 10800 12283 12100 08/11/2005 2:39 PM 1107 1010 9527-04-SC-01-32-0 11500 13030 11300 08/11/2005 2:41 PM 1107 1010 (1) AL - Action Level

Survey Release Record Scan Area Results Survey Unit 9527-0004 9527-0004 SCAN AREA 1 SECTIONS 1 THROUGH 5 Backgound Action Level Results Above Sample Name (cpm) (cpm) (cpm) AL Log Date Log Time E600 S/N Probe S/N 9527-04-SC-01-33-0 15400 17171 8740 08/11/2005 2:56 PM 1107 1010 9527-04-SC-01-34-0 18100 20020 9270 08/11/2005 2:59 PM 1107 1010 9527-04-SC-01-35-0 18900 20862 9840 08/11/2005 3:02 PM 1107 1010 9527-04-SC-01-36-0 15700 17488 9340 08/11/2005 3:04 PM 1107 1010 9527-04-SC-01-37-0 18100 20020 9240 08/11/2005 3:08 PM 1107 1010 9527-04-SC-01-38-0 16500 18333 9220 08/11/2005 3:11 PM 1107 1010 9527-04-SC-01-39-0 18300 20231 6910 08/11/2005 3:15 PM 1107 1010 9527-04-SC-01-40-0 20400 22438 8010 08/11/2005 3:17 PM 1107 1010 (1) AL - Action Level

Survey Release Record Scan Area Results Survey Unit 9527-0004 9527-0004 SCAN AREA 2 SECTIONS 6 THROUGH 10 Backgound Action Level Results Above Sample Name (cpm) (cpm) (cpm) AL Log Date Log Time E600 S/N Probe S/N 9527-04-SC-02-01-0 8930 10279 9320 08/16/2005 8:43 AM 1112 1010 9527-04-SC-02-02-0 9750 11159 8450 08/16/2005 8:45 AM 1112 1010 9527-04-SC-02-03-0 8920 10268 9190 08/16/2005 8:49 AM 1112 1010 9527-04-SC-02-04-0 9010 10365 9330 08/16/2005 8:52 AM 1112 1010 9527-04-SC-02-05-0 8580 9902 9080 08/16/2005 8:54 AM 1112 1010 9527-04-SC-02-06-0 9130 10494 9750 08/16/2005 8:56 AM 1112 1010 9527-04-SC-02-07-0 9650 11052 9160 08/16/2005 8:58 AM 1112 1010 9527-04-SC-02-08-0 9170 10537 9730 08/16/2005 9:00 AM 1112 1010 9527-04-SC-02-09-0 8750 10085 8780 08/16/2005 9:03 AM 1112 1010 9527-04-SC-02-10-0 10700 12176 8520 08/16/2005 9:04 AM 1112 1010 9527-04-SC-02-11-0 8960 10311 8660 08/16/2005 9:06 AM 1112 1010 9527-04-SC-02-12-0 9300 10676 8970 08/16/2005 9:08 AM 1112 1010 9527-04-SC-02-13-0 9400 10784 8780 08/16/2005 9:10 AM 1112 1010 9527-04-SC-02-14-0 9200 10569 10000 08/16/2005 9:12 AM 1112 1010 9527-04-SC-02-15-0 8760 10096 8210 08/16/2005 9:15 AM 1112 1010 9527-04-SC-02-16-0 8370 9676 8860 08/16/2005 9:17 AM 1112 1010 9527-04-SC-02-17-0 9200 10569 10100 08/16/2005 9:22 AM 1112 1010 9527-04-SC-02-18-0 10400 11855 8850 08/16/2005 9:23 AM 1112 1010 9527-04-SC-02-19-0 8780 10117 9610 08/16/2005 9:26 AM 1112 1010 9527-04-SC-02-20-0 9580 10977 10000 08/16/2005 9:27 AM 1112 1010 9527-04-SC-02-21-0 9970 11395 9050 08/16/2005 9:30 AM 1112 1010 9527-04-SC-02-22-0 9050 10408 10200 08/16/2005 9:32 AM 1112 1010 9527-04-SC-02-23-0 9120 10483 9960 08/16/2005 9:33 AM 1112 1010 9527-04-SC-02-24-0 8220 9514 8620 08/16/2005 9:35 AM 1112 1010 9527-04-SC-02-25-0 8770 10107 9520 08/16/2005 10:59 AM 1112 1010 9527-04-SC-02-26-0 8950 10300 9050 08/16/2005 11:00 AM 1112 1010 9527-04-SC-02-27-0 10000 11427 10000 08/16/2005 11:01 AM 1112 1010 9527-04-SC-02-28-0 9490 10880 9210 08/16/2005 11:02 AM 1112 1010 9527-04-SC-02-29-0 9640 11041 9620 08/16/2005 11:07 AM 1112 1010 9527-04-SC-02-30-0 9980 11406 10100 08/16/2005 11:08 AM 1112 1010 9527-04-SC-02-31-0 9670 11073 9270 08/16/2005 11:10 AM 1112 1010 9527-04-SC-02-32-0 9680 11084 9820 08/16/2005 11:11 AM 1112 1010 9527-04-SC-02-33-0 9220 10590 8790 08/16/2005 11:16 AM 1112 1010 9527-04-SC-02-34-0 8210 9503 8980 08/16/2005 11:17 AM 1112 1010 (1) AL - Action Level

Survey Release Record Scan Area Results Survey Unit 9527-0004 9527-0004 SCAN AREA 2 SECTIONS 6 THROUGH 10 Backgound Action Level Results Above Sample Name (cpm) (cpm) (cpm) AL Log Date Log Time E600 S/N Probe S/N 9527-04-SC-02-35-0 9420 10805 6850 08/16/2005 11:19 AM 1112 1010 9527-04-SC-02-36-0 8700 10031 9660 08/16/2005 11:21 AM 1112 1010 9527-04-SC-02-37-0 8710 10042 6800 08/16/2005 11:23 AM 1112 1010 9527-04-SC-02-38-0 7190 8400 7650 08/16/2005 11:25 AM 1112 1010 9527-04-SC-02-39-0 7950 9222 6590 08/16/2005 11:26 AM 1112 1010 9527-04-SC-02-40-0 8150 9438 7570 08/16/2005 11:29 AM 1112 1010 (1) AL - Action Level

Survey Release Record Scan Area Results Survey Unit 9527-0004 9527-0004 SCAN AREA 3 SECTIONS 11 THROUGH 15 Backgound Action Level Results Above Sample Name (cpm) (cpm) (cpm) AL Log Date Log Time E600 S/N Probe S/N 9527-04-SC-03-01-0 9480 10870 10000 08/11/2005 1:08 PM 1105 1006 9527-04-SC-03-02-0 9830 11245 10900 08/11/2005 1:13 PM 1105 1006 9527-04-SC-03-03-0 11200 12710 11000 08/11/2005 1:16 PM 1105 1006 9527-04-SC-03-04-0 10300 11748 11000 08/11/2005 1:20 PM 1105 1006 9527-04-SC-03-05-0 11100 12604 10600 08/11/2005 1:24 PM 1105 1006 9527-04-SC-03-06-0 10900 12390 10700 08/11/2005 1:26 PM 1105 1006 9527-04-SC-03-07-0 10500 11962 10400 08/11/2005 1:29 PM 1105 1006 9527-04-SC-03-08-0 11300 12817 11900 08/11/2005 1:31 PM 1105 1006 9527-04-SC-03-09-0 10600 12069 11500 08/11/2005 1:35 PM 1105 1006 9527-04-SC-03-10-0 11400 12924 8720 08/11/2005 1:39 PM 1105 1006 9527-04-SC-03-11-0 9410 10794 10400 08/11/2005 1:44 PM 1105 1006 9527-04-SC-03-12-0 11100 12604 10400 08/11/2005 1:47 PM 1105 1006 9527-04-SC-03-13-0 11200 12710 11000 08/11/2005 1:50 PM 1105 1006 9527-04-SC-03-14-0 10900 12390 10700 08/11/2005 1:52 PM 1105 1006 9527-04-SC-03-15-0 10800 12283 10200 08/11/2005 1:54 PM 1105 1006 9527-04-SC-03-16-0 10600 12069 11100 08/11/2005 1:57 PM 1105 1006 9527-04-SC-03-17-0 15100 16854 16400 08/11/2005 2:25 PM 1105 1006 9527-04-ER-03-17-1 15100 16854 19200 + 08/11/2005 2:22 PM 1105 1006 9527-04-SC-03-18-0 16700 18544 17100 08/11/2005 2:34 PM 1105 1006 9527-04-ER-03-18-1 16700 18544 27000 + 08/11/2005 2:31 PM 1105 1006 9527-04-SC-03-19-0 19700 21703 13300 08/11/2005 2:38 PM 1105 1006 9527-04-SC-03-20-0 14700 16430 14300 08/11/2005 2:46 PM 1105 1006 9527-04-ER-03-20-1 14700 16430 20100 + 08/11/2005 2:45 PM 1105 1006 9527-04-SC-03-21-0 15600 17383 15900 08/11/2005 2:56 PM 1105 1006 9527-04-ER-03-21-1 15600 17383 37800 + 08/11/2005 2:52 PM 1105 1006 9527-04-SC-03-22-0 23900 26106 25200 08/11/2005 3:00 PM 1105 1006 9527-04-SC-03-23-0 20200 22228 21900 08/11/2005 3:10 PM 1105 1006 9527-04-ER-03-23-1 20200 22228 37200 + 08/11/2005 3:07 PM 1105 1006 9527-04-SC-03-24-0 22100 24222 19300 08/11/2005 3:13 PM 1105 1006 9527-04-SC-03-25-0 15400 17171 14400 08/15/2005 1:52 PM 1112 1010 9527-04-SC-03-26-0 18400 20336 17400 08/15/2005 1:58 PM 1112 1010 9527-04-SC-03-27-0 13700 15370 31300 + 08/15/2005 2:05 PM 1112 1010 9527-04-SC-03-28-0 13900 15583 11900 08/15/2005 2:12 PM 1112 1010 9527-04-SC-03-29-0 12600 14202 12400 08/15/2005 2:16 PM 1112 1010 (1) AL - Action Level

Survey Release Record Scan Area Results Survey Unit 9527-0004 9527-0004 SCAN AREA 3 SECTIONS 11 THROUGH 15 Backgound Action Level Results Above Sample Name (cpm) (cpm) (cpm) AL Log Date Log Time E600 S/N Probe S/N 9527-04-SC-03-30-0 11700 13244 13800 + 08/15/2005 2:20 PM 1112 1010 9527-04-SC-03-31-0 14500 16219 14400 08/15/2005 2:24 PM 1112 1010 9527-04-SC-03-32-0 11800 13350 15300 + 08/15/2005 2:26 PM 1112 1010 9527-04-SC-03-33-0 17100 18966 15800 08/16/2005 2:21 PM 1105 1006 9527-04-SC-03-34-0 13100 14733 9260 08/15/2005 2:44 PM 1112 1010 9527-04-SC-03-35-0 14200 15901 8400 08/15/2005 2:46 PM 1112 1010 9527-04-SC-03-36-0 13400 15052 13500 08/15/2005 2:48 PM 1112 1010 9527-04-SC-03-37-0 13900 15583 11900 08/15/2005 2:51 PM 1112 1010 9527-04-SC-03-38-0 10500 11962 9610 08/15/2005 2:57 PM 1112 1010 9527-04-SC-03-39-0 10900 12390 8870 08/15/2005 2:58 PM 1112 1010 9527-04-SC-03-40-0 13200 14840 10000 08/15/2005 3:00 PM 1112 1010 (1) AL - Action Level

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0004 RELEASE RECORD Attachment 2c Split Sample Assessment Forms (2 Pages)

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0004 RELEASE RECORD Attachment 2d Preliminary Data Forms (2 Pages)

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0004 RELEASE RECORD Attachment 2e Graphical Representation of Data (4 Pages)

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0004 RELEASE RECORD Attachment 2f Sign Test Calculation (1 Page)

EAST MOUNTAIN SIDE SURVEY UNIT 9527-0004 RELEASE RECORD Attachment 2g COMPASS DQA Surface Soil Report with Retrospective Power Curve (3 Pages)