Text

MR m UNA m w am

FLORIDA POWER CORPORATION CRYSTAL RIVER UNIT 3 DOCKET NUMBER 50-302 /LICENSE NUMBER DPR-72 RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION ATTACHMENT B RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION REQUIRED FOR THE DEVELOPMENT OF THE CONFIRMATORY LOCA AND NON-LOCA MODELS (PROPRIETARY)

U. S. Nuclear Regulatory Commission Page 1 of 2 3F0511-02 Request for Additional Information Required for the Development of Confirmatory LOCA and non-LOCA Models for the CR-3 Extended Power Uprate Florida Power Corporation (FPC), doing business as Progress Energy Florida, Inc. hereby provides a response to a request for additional information (RAI) required for the development of confirmatory Loss of Coolant Accident (LOCA) and non-LOCA models for the Crystal River Unit 3 (CR-3) Extended Power Uprate (EPU). Below is the NRC RAI that was forwarded to CR-3 by electronic mail on February 17, 2011.

NRC Item 4 Non-LOCA Analysis Report(s). the sections of turbine trip, loss offeed and steam line break CR-3 Response Analysis Input Summary (AIS) documents for the following events are attached (see the enclosed CD-ROM):

1. Turbine trip and load reject (AIS Document) 51-9060386-003