Report EGS-TR-HC589-01, Seismic Qualification Test Report for Structural Verification Testing of Iccms Cabinet Assembly
ML12284A138
Person / Time
Site: Crystal River Duke Energy icon.png
Issue date: 05/25/2012
From: Thelen M
Qualtech NP
To:
Office of Nuclear Reactor Regulation
References
EGS-TR-HC589-01
Download: ML12284A138 (195)


Text

{{#Wiki_filter:May 25, 2012 Seismic Qualification Test Report for Structural Verification Testing of ICCMS Cabinet Assembly Report No. EGS-TR-HC589-01 Prepared by: QualTech NP a business unit of Curtiss-Wright Flow Control Company Huntsville Operations 125 West Park Loop Huntsville, AL 35806 Scientech P.O. 11-0170 QualTech Job No. HJ 1769 I CUR Ti$ , **WRIGHT

  • 9_ Flow Control Company QualTech NP 125 West Park Loop, Huntsvlle, AL 35806 Tel (256) 722-8500 Fax (256) 722-8533

Report No. EGS-TR-HC589-01 Page No. i TECHNICAL DOCUMENT DOCUMENT TYPE: (REPORT/PLAN/PROCEDURE) Revort DOCUMENT NUMBER: EGS-TR-HC589-01 TITLE: Seismic Qualification Test Report for Structural Verification Testing of ICCMS Cabinet Assembly 4ýý 'c/2-3/17-PREPARED BY: +/-- Matthew -Thelen I /Date PROGRAM MANAGER: Date Ron Gou Date ENGINEERING VERIFIER: APPROVAL: Ron t-olub Date QUALITY ASSURANCE: QAMIQAA Date Form 611 - Revised 02FEB2006

Report No. EGS-TR-HC589-01 Page No. ii TABLE OF CONTENTS Page A pproval Page........................................................................................................................ i Table of C ontents................................................................................................................... ii 1.0 SU M M A R Y................................................................................................................ 1 2.0 EQUIPMENT TESTED............................................................................................. 1 3.0 PROCEDURES AND RESULTS.............................................................................. 1

4.0 REFERENCES

1 LIST OF APPENDICES APPENDIX I QualTech NP TP Q 1206.0, Revision 0 APPENDIX II Seismic Qualification Test Results for the ICCMS Cabinet APPENDIX III Notice of Anomaly 2012-010, Non Conformance Report NCR #12-65 Rev. 0, and Certificate of Conformance #CJ 1579.1 I SFlow Control Company Qua/rech NP 125 West Park Loop, Huntsville, AL 35806 Tel (256) 722-8500 Fax (256) 722-8533

Report No. EGS-TR-HC589-01 Page No. I 1L0

SUMMARY

The cabinet, listed below, was subjected to structural seismic qualification testing as defined in Test Procedure No. Q1206.0, Revision 0 (Reference 6). The seismic test results are contained in Appendix II. 2.0 EQUIPMENT TESTED Supplier: Type: Part No.: Serial No.: Drawing b Note: Scientech, Idaho Falls Operations, a Curtiss Wright Flow Control Company ICCMS Cabinet NUS-C130PA-1, Revision B 1103379 qo.: NUS-A321XD The part number was referenced during the preparation of the test plan and subsequently was changed to the drawing number. 3.0 PROCEDURES AND RESULTS The cabinet described in paragraph 2.0 above, was received, inspected and mounted, as described in the applicable paragraphs listed in Test Procedure 1206.0 Revision 0 (Reference 6). Testing was performed on March 22, 2012 at the QualTech NP Cincinnati Ohio test facility. The cabinet was mounted as specified in the applicable Paragraphs and/or Figures of the Reference 6 test plan and attached to the seismic test table as shown in Appendix II Part 1. The cabinet was not powered nor monitored during the performed tests. The cabinet was subjected to a resonant search as defined in the Reference 6 procedure; found resonances are defined in Appendix II. A total of six (5 OBE-Level and I SSE-Level) 30 second duration tri-axial RMF tests were performed and completed for the test series (for test run descriptions see Tables UI-1 in Appendix II). Photographs showing test setup details and seismic data plots are also contained in Appendix II. The cabinet was not subjected to a post seismic resonance search per NOA 2012-010 in Appendix III. REFERENCES

1) 10CFR21, "Reporting of Defects and Noncompliance".
2) 10CFR50/Appendix B, "Quality Assurance Criteria for Nuclear Power Plants and Fuel Reprocessing Plants".
3) IEEE 323-1974/1983, "IEEE Standard for Qualifying Class IE Equipment for Nuclear Power Generating Stations".
4) IEEE 344-1975/1987, "IEEE Recommended Practice for Seismic Qualification of Class 1E Equipment for Nuclear Power Generating Stations".
5)

Scientech Purchase Order No. 11-0170, Change Order 2 (or latest approved revision). 4.0 I uFlow Control CampanP Qualfech NP 125 West Park Loop, Huntsville, AL 35806 Tel (256) 722-8500 Fax (256) 722-8533

Report No. EGS-TR-HC589-01 Page No. 2

6)

QualTech NP Cincinnati Test Procedure No. Q1206.0 Revision 0, "Seismic Qualification Test Procedure for ICCMS Cabinet Assembly." n ro Company QualTech NP 125 West Park Loop, Huntsville, AL 35806 Tel (256) 722-8500 Fax (256) 722-8533

APPENDIX I (22 Pages) QualTech NP TP Q1206.0, Revision 0 I CUR77SS5 Oua (Tech NP 125 West Park Loop, Huntsville, AL 35806 Tel (256) 722-8500 Fax (256) 722-8533

Report No. EGS-TR-HC589-01 Appendix I, Page No. 1 I CURTISS 0 WRIGHT JCFIow Control Company QualTech NP Test Procedure No. Q1206.0 Revision 0 Seismic ification Test Procedm for ICCMS Cabbwt Assemli This is the property of QuafTech NP. This procedure contains proprietary and confidential information that must not be duplicated or disclosed other than as expressly authorized by QualTech NP. This procedure (numbered above) is exclusively prepared to support the qualification of items li~ted herein, or items referenced in certification documents issued in reference to this procedure number. This procedure may not be used for any other purpose or by any other organization except QualTech NP or their authorized agents and those who have licensed this document through QualTech NP. QualTech NP Reference # CW98/CJ1579 Prepared by/ Date: Independent Desig Management Revie eýJooatfep ite T~st Enbineer ewn Review andb at: )

  • /

by! Date: Marie S. Nemnier, Seismic and EQ Manager Quality Assurance Review by/ Date: - 2-

Report No. EGS-TR-HC589-01 Appendix I, Page No. 2 QUALTECH NP TP Q1206.0 REV.0 PG 2 Record of Revision o 3/6/1 JAD MSN MDM Original Issue Table of Contents 1.0 2.0 3.0 4.0 5.0 6.0 Scope 3 Applicable Documents, Codes and Standards 3 Description of Items to be Tested 4 Description of Program and Sequence 4 Acceptance Criteria 4 Final Report 4 Attachment A -Seismic Test Criteria 6 Attachment B - Functional and Operability Component Test Procedures for ICCMS Cabinet Assembly_ 7 Attachment C - Drawings 11 Total Pages: 22

Report No. EGS-TR-HC589-01 Appendix I, Page No. 3 QUALTECH NP TP Q1206.0 REV.O PG 3 Seismic Qualificaton Test Procedure The purpose of this procedure is to present the rationale for the nuclear equipment qualification program to be performed on the equipment defined in Section 3.0 for Qual Tech NP Huntsville. This program will be conducted at the QualTech NP test facility in Cincinnati, Ohio. The qualification will be implemented by seismic proof testing to the requirements presented in Attachment A. Testing will be conducted by qualified personnel in accordance with the qualification requirements as presented in the test procedure. Testing will be conducted to demonstrate proper performance of the test samples' safety functions. !2. Appicbl ou ens Coe and6-Standa.ds All testing shall be conducted to meet the requirements of the following documents, codes, standards and regulatory documents.

1) IEEE 344-1987, "IEEE Recommended Practices for Seismic Qualification of Class 1E Equipment for Nuclear Power Generating Stations".
2) 10 CFR Part 21, "Reporting of Defects and Noncompliance".
3) 10 CFR Part 50 Appendix B, "Quality Assurance Criteria for Nuclear Power Plants and Fuel Reprocessing Plants".
4) ASME NQA-1, "Quality Assurance Requirements for Nuclear Facility Applications".
5) ANSI/ASME N45.2-1977, "Quality Assurance Program Requirements for Nuclear Facilities".
6) QualTech NP Quality Assurance Manual.
7) Trentec-GSQTP Rev. 6 "Generic Seismic Qualification Technical Procedure".
8) Qual Tech NP Huntsville Purchase Order #HP00001 165

Report No. EGS-TR-HC58901 Appendix I, Page No. 4 QUALTECH NP TP Q1206.0 REV.0 PG 4 1 3.0 Decito of itm to beTse Test sample will be supplied by Qual tech NP HuntsvillelSclentech with various equipment and dummy weights. Trentec-GSQTP is the Generic. Seismic Qualification Technical Procedure will be used for this project. The seismic mounting and loading, baseline and post-seismic functional tests, as well as seismic operability requirements are found in Attachment 8 for the item shown in Table 3.1. The seismic test levels (RRS) are defined in Attachment A. The acceptance criteria are the safety-function requirements translated to criteria that will be applied during the qualification program. The acceptance criteria employed are: a) The functional requirements are structural integrity only. Deviations from any of the above requirements shall be documented, evaluated, and approved by Qual tech NP Huntsville, through the generation of a Non-Conformance Report (NCR). The NCR will be included in the qualiflication report. The final report will certify that the testing was done in accordance with the approved test procedure, Qual tech NP Huntsville provided specifications and the applicable codes, standards and regulations listed in Section 2.0 of this procedure. The report will be include or reference the procedures and results for each phase of the test program.

Report No. EGS-TR-HC589-01 Appendix I, Page No, 5 TP Q1203.0 REV.O PG 5 Seismic Test Criteria Site Specific RRS OBE = 70% of SSE Damping = 5%

Report No. EGS-TR-HC589-01 Appendix I, Page No. 6 QUALTECH TP Q1203.0 REV.O PG 6 SSE Required Response Spectrum 10.0 Vertical and Horizontal Date .Points Freguencg Accaleratign 1.0 0.5 3.0 1.5 .o. 110ioo 1.6 20.0 0.6 50.0 0.5 .OBE acceleration = 70% of SSE " IU _E IiJt~ 0.1 10 100 Frequency (Hz)

Report No. EGS-TR-HC589-01 Appendix I, Page No. 7 QUALTECFi TP Q1206.0 REV.0 PG 7 Functional and Operability Test Procedures for ICCMS Cabinet Assembly PN: NUS-A321XD

Report No. EGS-TR-HC589-01 Appendix I, Page No. 8 QUALTECH TP Q1206.0 REV.0 PG 8 PLAN INTRODUCTION The purpose of this procedure is to present requirements for the inspection and functional testing of ICCMS Cabinet Assembly. A requirement of this procedure is that purchasing and/or shipping documents establish traceability to the Original Equipment Manufacturer (OEM) or the sponsoring utility. This procedure is intended to permit verification of the condition and performance prior to and after seismic testing as well as, operability during the seismic testing. The procedure is to be used with the seismic qualification technical procedure (Trentec-GSQTP) to provide a complete qualification program. The safety-related function of a cabinet assembly is to maintain structural integrity during normal and accident conditions. TEST SEQUENCE Testing shall be conducted in the following sequence: Base Resonance Search Seismic Test Post Resonance Search Visual Inspection The test cabinet assembly shall be visually inspected. Any damage shall be noted and reported via a non-conformance report (NCR). Specimens will be tagged. Information on the tag shall include the sponsoring utility and unique test sample identification number. Base Resonance Search A resonance search will be conducted via base excitation, on a single axis basis, using an approximately 0.2g constant amplitude sine sweep from 1 to 50 Hertz, at a sweep rate of two octaves per minute, or less. Accelerometers shall be located at eight different mounting locations. Seismic Test Test sample will be subject to 5 OBE tests and 1 SSE tests with a minimum of 15 seconds strong motion, enveloping the site specific RRS, as shown in Attachment A. Seismic Mounting Test sample shall be mounted to the seismic table surface using four each commercial grade a" bolts with lock and flat washers. Tightening torque value and hardware size will be recorded.

Report No. EGS-TR-HC589-01 Appendix I, Page No. 9 QUALTECH TP Q1206.0 REV.0 PG 9 Seismic Operability Test The operation of the test specimen is summarized in the table below. Test Checking For OBE 1 OBE 2 OBE 3 OBE 4 Structural Integrity OBE 5 SSE I During the seismic test, test sample shall be visually inspected for any structural damage. Post Resonance Search Repeat Base resonance search in its entirety.

Report No. EGS-TR-HC589-01 Appendix I, Page No. 10 QUALTECH TP Q1206.0 REV.0 PG 10 Seismic Operability Data Sheet For Test Switch Panel Test # Test Checking for (to be O~d in aftv L-s*v) OBE I OBE 2 OBE 3 Structural Integrity OBE 4 OBE 5 SSE 1 SSE 2 Instrument and Equipment List Serial No. Range Item Calibration Due Test Set-Up Reviewed By/Date: Test # Structural Integrity Maintained YES I NO YES / NO YES I NO YES / NO YES / NO YES I NO YES / NO YES I NO YES / NO YES J NO Notes: Complied with Test Requirements: Tested By/Date: NCR Number: Reviewed By/Date:

Report No. EGS-TR-HC589-01 Appendix i, Page No. 11 TP Q1206.0 REV.0 PG 11 Drawings: NUS-A321XD Sheets I through 11 Rev. A

U C A~.. ....- 8 .~~~1~ I ~iP I 'II ~ a -r AUJi'A.RY.* A H -U 0 "3 0 0 ~3 rn 0 C, Wb .t. .M. ~%. 7 z5VMV ~CiICS A-A

C. -C D c I A:. C -.4-u 0 ..J. N) 0 6 -D G) C~) >1 oCL C6 I ~ ~ A

CC AX 'AP V. K3 x _____0 A-q M .I iV 0 C mp

NG) -7U SA-J L.Ba ik ENa NUC-EAR Aý--7 3-FL.ATC-

a C I- -~ 'N m C) 7 r ~I*Th~ 0)0m

  • 0-u 0)

~ 4: 1*1111** 4. -1

0 m CL -777~

AUXU1ARY '~W-SCc4 -C ~ ~ Nu~~~ifAR~~ m'lfR~l.. =rrgr 0

p DErAiL.E 0 ~rn G-) m <~0 AU)O.!ARY MEW ~ -

F C

LE ýTO 10 C NUCtEAR SAFET1 RUA TED COA X'JS-A3~I~ ~ I I ~ 16.4 t41141Mtr1~9W1

AU I 4>,

i

ý-C .':ý fc 0 0 C -u m C) A32 IXD 7 y q

0c m G) m [CCA fnhfi ...........A.... I

r4 0 m C) ,I~1p U, uI~1

  • ' II ll~j I'

till lb --I m

JlzC, 9

R, m -a CAPNE- ýRW

  • .*.j 14L, :

C.Fjlf

APPENDIX 1I (159 Pages) Seismic Qualification Test Results for the ICCMS Cabinet Content Summary Part I Seismic Test Result Summary and Test Setup Photographs Part 2 Test Response Spectrum (TRS) and Acceleration Time History Plots Part 3 Transmissibility Plots Part 4 Equipment Used Sheets Page Numbers 1-7 8-141 142-151 152-159 I CURTI55 Quarrech NP 125 West Park Loop, Huntsville, AL 35806 Tel (256) 722-8500 Fax (256) 722-8533

Report No. EGS-TR-HC589-01 Appendix II, Page No. I Part 1 Seismic Test Result Summary and Test Setup Photographs I CURTISS C company Qua TTech NP 125 West Park Loop, Huntsville, AL 35806 Tel (256) 722-8500 Fax (256) 722-8533

Report No. EGS-TR-HC589-01 Appendix I, Page No. 2 INTENTIONALLY LEFT BLANK I CURMTSS

  • ufeWWGHTr piJ lw Control Company Quarffech NP 125 West Park Loop, Huntsville, AL 35806 Tel (256) 722-8500 Fax (256) 722-8533

Report No. EGS-TR-HC589-01 Appendix II, Page No. 3 Seismic & Mounting Data Sheets and Seismic Test Log

Report No. EGS-TR-HC589-01 Appendix II, Page No. 4 Photographs of Resonance Search and Survey Accelerometer 4X5Y6Z mounted on the Top Center of the Cabinet above the LCD Monitor

Repot No. EGS-TR-HC589-01 Appendix H1, Page No. 5 Photographs of ,arcn ani 5urvey Accearomever 7 Cabinet near the Center mounted Inside the

Report No. EGS-TR-HC589-01 Appendix II, Page No, 6 Photographs of Resonance Search and Survey Accelerometer 9X10¥ Cabinet near the Center below the Monitor , mounted inside the

Report No. EGS-TR-HC58M-01 Appendix II, Page No. 7 view Of the 5eI~mC Test smtp

Report No. EGS-TR-HC589-01 Page No. 8 Part 2 Test Response Spectrum (TRS) and Acceleration Time History Plots I CUR T1S$ w rCompany Ouarrech NP 125 West Park Loop, Huntsille, AL 35806 Tel (256) 722-8500 Fax (256) 722-8533

Report No. EGS-TR-HC589-01 Appendix 11, Page No. 9 Seismic TRS Plots Note: DX2Y3Z is the control accelerometer mounted on the center of the underside of the seismic table surface.

TEST RESPONSE SPECTRA Data File: Q1206001 22-12 2:34p Accel No. 1 116 Octave ZPA: .56 gPk REQUIRED RESPONSE SPECTRA RRS FMe: Q1206OBE.RRS 22-12 9:17a 5.0 4.0 3.0 2.0 A c eI e r at 0 a 1.0 .8 .6 .5 LJ -IL Z e ~ ~ ~ ~ ~ ~ ~ ~... 2. 4 ~ ~ T 6 0 0 3 06 7 0I Sm (g's) .4 .3 .2 .1 10 Frequency (Hertz) LZRPLOT Ver. 2. In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix It, Page No. 11 TEST RESPONSE SPECTRA Data File: 01206001 22-12 2 :3 4p REQUIRED RESPONSE SPECTRA Accel No. 1 1/6 Octave ZPA -56 gPk RRS File: Q1206OBE.RRS 22-12 9:17a Required Response Spectra Fre Accel Fre Accel Fre Accel 1.05

50.

35 3.00 1.05 20.00 .35 100.00 .35 Test Response Spectra Freq 5%Damp 2.0%Damp 3.0%Damp 5.0%Damp 7.WoDamp Z GPk GPk GPk GPk GPk 1t0 .53 .45 .41 .36 .32 1.12 1.62 L09 94 .72 .59 1.26 1.71 1.27 [08 .83 .70 1.41 1.59 .94 .83 .74 .66 1.58 1.81 114 .97 .77 .63 1.78 1.46 1.06 .89 .72 .64 2.00 2.11 132 L14 .95 .83 224 2.07 1.42 [23 .11 .98 2.51 1.34 118 1.10 .96 .88 2.82 107 1.84 1.54 1.22 L05 316 4.04 2.16 1.78 1.36 1.12 3.55 2.82 1.60 1.41 1.28 1.14 3.98 2.85 L94 1.71 1.39 117 4.47 2.55 224 1.91 1.46 1.20 5.01 2.97 1.90 1.73 1.42 1.22 5.62 3.83 L84 L57 1.37 L24 631 3.52 2.36 2-08 170 L45 7.08 3.33 2.09 1.81 1.49 1.30 7.94 3.93 2.86 2.42 L87 154 8.91 3.63 1.97 [SO 1.46 L24 10.00 2.81 1.95 L64 1.27 114 1122 2.04 1.42 1.30 L17 1.05 12.59 3.43 1.74 1.40 1.08 .91 14.13 1.79 1.14 1.04 .89 .80 15.85 1.49 .96 .90 .84 .79 17.78 2.09 1.28 1.10 .91 .81 19.95 1.92 107 .98 .83 .74 22.39 136 .88 .80 .73 .68 2512 1.13 .85 .80 .75 .71 28.18 .83 .70 .70 .68 .67 31.62 .95 .80 .76 .71 .68 35.48 .74 .68 .66 .64 .63 39.81 .78 .69 .67 .64 .62 44.67 .72 .62 .62 .61 .59 50.12 .75 .63 .59 .56 .56 56.23 .87 .68 .65 .61 59 63.10 .74 .62 .61 .61 .60 70.79 .64 .61 .61 .60 .59 79.43 .65 .59 .58 .58 .58 89.13 .67 -59 .58 .57 .56 100.00 .74 .58 .57 .56 .55 LZRPLOT Ver. lln 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206001 22-12 2:34p Accel No. 2 1/6 Octave ZPA: .60 gPk REQUIRED RESPONSE SPECTRA RRS File: Q1206OBE.RRS 22-12 9:17a 5.0 4.0 3.0 2.0 A C C e 1 e r a t i 0 n 1.0 .8 .6 .5 i.- A-A k e S -r i... l a : _______7J.. L i.'....71- .230..6... 23 4 5 6 7 8 10 20 30 40 50 60 70 80 10 (D M o C (g's) .4 .3 .2 .1 30 Frequency (Hertz) LZRPLOT Ver. 2. In 03-22-2012

Report No. EGS-TR-HC589.01 Appendix II, Page No. 13 TEST RESPONSE SPECTRA Data File 01206001 22-12 2"34p REQUIRED RESPONSE SPECTRA Accel No. 2 1/6 Octave ZPA:.60 gPk RRS File: Q12060BE.RRS 22-12 9:17a Required Response Spectra Accl Freq Accol Fre. Accel 35 10.00 1.05 50.0 .35 3.00 L05 20.00 .35 100.00 35 Test Response Spectra Freq .5%Damp 2.0%Damp 3.0%Damp 5.0%Damp 7.0%Damp (z) GPk GPk GPk GPk GPk .85 .64 .55 .44 .37 112 1.89 .95 .80 .62 .52 126 1.08 .78 .66 52 .46 141 1.16 .71 .61 .52 .45 158 .84 .72 .66 .58 .53 1.78 1.78 121 .99 .76 .63 2.00 158 L12 .96 .76 .64 2.24 3.07 1.62 127 .95 .81 2.51 221 1.97 L71 1.33 1.07 282 2.81 1.82 1.53 L23 L08 316 3.64 L96 1.55 L12 .91 3.55 4.85 2.46 1.87 1.38 114 3.98 3.15 1.76 1.52 L31 114 4.47 2.89 1.77 152 131 1.15 5.01 2.78 2.26 194 1.59 1.35 5.62 2.40 1.42 1.31 124 1.15 6.31 4.10 237 194 142 1.15 7.08 4.45 2.51 2.04 1.52 123 7.94 3.25 2.19 1.85 145 L21 8.91 3.15 1.90 1.68 139 L20 10.00 3.58 1.90 1.51 1.23 .10 1122 2.52 138 1.20 1.00 .88 12.59 1.83 1.27 119 108 1.01 14.13 2.01 1.41 133 1.21 1.13 15.85 3.03 L76 1.53 137 1.26 17.78 488 2.96 2.50 1.90 1.61 19.95 4.40 2.60 2.27 1.88 162 22.39 2.72 L84 L60 135 1.21 25.12 1.39 101 .95 .92 .91 2&18 1.20 1.01 101 .98 .94 31.62 L02 .93 .93 .92 .90 3548 .93 .75 .75 .77 .78 39.81. .89 .78 .78 .76 .75 44.67 .82 .66 .64 .66 .67 50.12 .74 .67 .66 .65 .65 56.23 .85 .71 .68 .66 .65 63.10 .72 .67 .65 .64 .64 70.79 .73 .63 .62 .60 .59 79.43 .68 .62 .61 .60 .60 89.13 .69 .61 .60 .60 .59 100.00 .66 .63 .62 .61 .61 LZRPLOT Ver. 1.n 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206001 22-12 2 :34 p Accel No. 3 1/6 Octave ZPA:..63 gPk REQUIRED RESPONSE SPECTRA RRS ile: QI206OBE.RRS 22-12 9:17a 5.0 4.0 3.0 2.0 A c C 1 r a t 0 a' 1.0 .8 .6 .5 .: _ - _ _* _ _ -.?~.... .,i 0 7 I-:'. P If..... M E. i CL -0CJ w 11 (g's) .4 .3 .2 .1 I 2 Frequency (Hertz) 20 30 40 50 60 70 80 100 LZRPLOT Ver. 2.In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 15 TEST RESPONSE SPECTRA Data File: Q1206001 22-12 2:34 p REQUIRED RESPONSE SPECTRA Accel No. 3 1/6 Octave ZPA.-.63 gPk RRS File: Q1206OBERRS 22-12 9:.17a Required Response Spectra Freq Accel Freq Accel Freq Accel L00 .35 10.00 L05 50.00 .35 3.00 1.05 20.00 .35 100.00 .35 Test Response Spectra Freq .5%Damp 2.0%IDarp 3.0%Damp 5.0%Damp 7.0%Damp (hz) GPk GPk GPk GPk GPk too 1.02 .58 .48 .38 .32 L12 1.34 .80 .64 .51 .43 126 1-54 1.17 .99 .75 .64 1.41 123 1.01 .90 .73 .61 1.58 1.62 1.15 .95 .72 .60 1.78 1.57 1.15 .98 .81 .70 2.00 2.29 1.36 1.08 .79 .69 2.24 2.66 1.56 1.27 .99 .85 2.51 2.81 1-57 1.35 1.05 .91 2.82 2.67 1.78 1-53 1.25 L06 3.16 3.53 1.97 1.57 L12 .90 3.55 2.86 1.72 1.48 L18 1.01 3.98 2.55 1.85 1.65 1.30 1.08 4.47 3.19 1.82 1.47 1.15 103 5.01 334 1.82 1.67 1.42 L23 5.62 3.29 1.90 1.54 1.27 1.17 6.31 2.20 1.72 1.54 1.30 1.11 7.08 3.03 1.91 072 1.44 125 7.94 3.32 1.93 1.59 1.38 L26 8.91 4.75 2.12 L75 139 1.24 10.00 2.86 2.27 193 1.51 1.26 1122 4.15 2.07 1.62 1.23 1.14 12.59 1.39 1.09 1.01 .93 87 14.13 L13 .83 .80 .75 .73 15.85 1.80 1.08 .96 .83 .75 17.78 1.51 .98 .91 .84 .79 19.95 L32 L09 L03 .95 .88 2239 1.67 .18 1.04 .98 .92 25.12 179 1.14 .99 .88 .85 28.18 1.84 1.33 1.14 .98 .89 3162 1.27 .94 .93 .91 .89 35.48 1.27 1.01 .99 .95 .91 39.81 .92 1.01 .99 .95 .91 44.67 1.02 .96 .94 .90 .87 5012 .91 .93 .91 .86 .83 56.23 .87 .82 .80 .76 .74 63.10 .76 .69 .69 .68 .68 70.79 .74 .68 .67 .67 .67 79.43 .70 .71 .70 .69 .68 89.13 .70 .67 .67 .67 .67 100.00 .75 .72 .70 .68 .68 LZRPLOT Ver. 2.In 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206001 22-12 2:34p Accel No. 4 1/6 Octave ZPA: 1.15 gPk REQUIRED RESPONSE SPECTRA RRS File: Q12060BE.RRS 22-12 9:17a A C C e r a ti 0 (g's) 25.0 10.0 7.0 5.0 3.0 2.0 1.0 .7 .5 k.,. ,i........... .] i t c t Io ll ...T"- i .[J. 12 3 4 5 67 8 10 20 30 40 50 60 70 80 1C Frequency (Hertz) G) Co C65 .3 .2 .1 M0 LZRPLOT Ver. 2. In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix I, Page No. 17 TEST RESPONSE SPECTRA Data File: Q1206001 22-12 2:34p Accel No. 4 1/6 Octave ZPA. L15gPk Required Response Spectra Freq Accel Freq Accel Freq Accel 100 35 10.00 1.05 50.0 .35 3.00 105 20.00 .35 100.00 .35 REQUIRED RESPONSE SPECTRA RRS File: Q12060BE.RRS 22-12 9:17a Test Response Spectra Freq .5%Damp (.*z GPk 58 1.12 1.60 1.26 L77 141 1.67 1.58 1-97 L78 1.55 2.00 2.17 224 2.22 2.51 1.56 2.82 3.27 3.16 4.38 3.55 3.06 3.98 3.37 4.47 2.75 5.01 3.60 5.62 4.90 6.31 4.28 7.08 5.00 7.94 5.81 &91 6.08 10.00 5.66 1122 539 12.59 12.18 14.13 7.50 15.85 7.28 17.78 5.64 19.95 3.02 22.39 2.32 25.12 2.03 28.18 2.08 31.62 1.78 35.48 2.93 39.81 2.41 44.67 1.70 50.12 2.67 56.23 L88 63.10 2.06 70.79 2.70 79.43 335 89.13 3.47 100.00 1.78 2.0%Damp 3.0%Damp 5.0%Damp GPk GPk GPk .48 .44 38 1.11 .97 .74 1.29 110 .86 98 .86 .75 1.21 1.04 .81 1.07 .91 .75 133 115 .97 1.49 1.28 1.16 128 L16 1.01 1.96 L65 1.30 2.39 1.98 1.52 1.79 159 142 2.17 L90 1.54 2.51 2.16 168 2.27 2-11 1.80 2.29 1.99 L72 2.97 2.64 2-18 2.96 2.53 2.07 4.32 3.66 2.85 3-33 3.06 2.48 3.63 319 2.69 3.95 3.80 3.37 610 4.83 3.41 5.11 4.45 3-55 3.90 3.60 332 3.46 2.95 2.49 2.11 L93 174 1.87 1.70 1-58 L48 1.46 1-50 163 155 141 1.45 143 1.40 1.74 165 1-52 1.80 167 153 138 139 1.32 L66 137 1.22 1.48 135 1.21 147 1.33 126 170 158 L41 2.42 2.12 1.78 2.63 225 1.89 160 157 1.51 7.0%Damp GPk .34 .60 .73 .68 .67 .66 .84 1.02 .92 1.14 126 1.27 L30 1.40 158 1.51 1.86 L93 2.36 2.10 232 2.95 2.75 3.06 3.00 2.24 L68 1.52 L46 1.33 1.37 1.43 1.43 126 1.18 1.17 1.20 1.30 1.57 1.70 1.46 LZRPLOT Ver. 2.1n 03-22-2012

TEST RESPONSE SPECTRA Data Fe: Q1206001 22-12 2 :34 p Accel No. 5 1/6 Octave ZPA: 1.62 gPk REQUIRED RESPONSE SPECTRA RRS ile: Q1206OBE.RRS 22-12 9:17a A C C e r a ti 110 (9's) 50.0 30.0 20.0 10.0 7.0 5.0 3.0 2.0 1.0 .7 .5 .3 .2 .I I I 'il ,~~ ~ I ".I ,,\\V 20 30.4 .0 ,70.0 23

4.

5 6 8 10 20 30 40 50 60 70 80 1C m ro~ I I I 0 Frequency (Hertz) LZRPLOT Ver. 2. In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 19 TEST RESPONSE SPECTRA Data File: Q1206001 22-12 2:34p REQUIRED RESPONSE SPECTRA Accel No. 5 1/6 Octave ZPA: 1.62 gPk RRS File. Q12060BERRS 22-12 9.17a Required Response Spectra Fr Accel Freq Accel F Accel FrO .35 10.00 L05

M

.35 3.00 L05 20.00 .35 100.00 35 Test Response Spcctra Frcq .5%Damp 2.0%Damp 3.0%Damp 5.0%Damp 7.0%Damp LhZ0 GPk GPk GPk GPk GPk .89 .68 .58 .45 -38 1.12 1.96 1.02 .86 .68 .57 126 1.12 .79 .71 .56 .48 1.41 126 .76 .66 .56 .50 1.58 .96 .77 .72 .64 .58 1.78 1.93 1.36 L14 .88 .73 2.00 165 1.22 1.05 .84 .73 224 335 1.82 1.43 107 .95 2.51 2.58 2.24 [90 1.44 1.16 2.82 3.54 239 2.04 1.59 139 3.16 4.71 2.54 2.06 1.54 125 3.55 6.32 3.18 2.54 1.91 1.60 3.98 4.52 2.63 238 2.06 1.83 4.47 4.73 2.65 2.45 2-16 L90 5.01 532 3.93 3.42 2.85 258 5.62 5.91 3.66 3.49 3.27 3.08 6.31 14.06 8.44 6.72 5.45 4.59 7.08 24.88 12.39 9.82 7.99 6.62 7.94 27.71 15.52 12.69 9.18 717 8.91 1Z45 7.78 6.96 5.81 4.79 10.00 8.79 5.11 4.60 3.99 3.53 1122 4.95 3.34 3.09 2.86 2.76 12.59 3.12 2.53 2.48 2.45 2.44 14.13 2.90 2.66 2.57 2.46 2.41 15.85 3.22 2.45 2.42 2.38 2.34 17.78 3.85 2.99 2.81 2.61 2.49 19.95 3.95 2.86 2.68 2.44 2.42 22.39 2.99 2.67 2.66 2.57 2.47 25.12 3.99 2.80 2.60 2.40 230 2818 5.16 3.23 2.77 2.26 2.19 31.62 3.92 2.56 231 2.08 Z08 35.48 411 Z81 2.54 2.26 2.10 39.81 3.01 2.08 1.97 [84 1.82 44.67 2.72 L99 L91 190 1.87 50.12 2.08 L90 189 185 1.82 562-3 2.99 Z27 2.12 1.95 1.87 63.10 2.18 1.95 188 181 1.79 70.79 2.18 1.89 1.87 1.83 1.80 79.43 2.76 2.42 2.29 2.10 1.98 89.13 3.18 2.39 2.16 1.97 1.89 100.00 2.50 2.01 1.93 1.83 177 LZRPLOT Ver. 2.1n 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206001 22-12 2:3 4 p Accel No. 6 1/6 Octave ZPA: .81 gPk REQUIRED RESPONSE SPECTRA RRS File: Q1206OBE.RRS 22-12 9:17a 10.0 7.0 5.0 4.0 3.0 2.0 .9 .7 r -{ I I : A I . i .I r.. I I ? f 1 IV 'I A c c 1 r a t i 0 n -F - --i 17 Yý,.Vk A so .7 -Id I X >1 lZ M (D T Z = 00 8 g (9,S) 's .4 .3 .1 I 2 3 4 5 6 7 8 10 20 30 40 50 60 70 80 100 FTequency (Hertz) LZRPLOT Ver. 2. In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 21 TEST RESPONSE SPECTRA Data File: Q1206001 22-12 2-34p Accel No. 6 1/6 Octave ZPA:.81 gPk Required Response Spectra REQUIRED RESPONSE SPECTRA RRS File: Q1206OBE.RRS 22-12 9:17a Fr.q Acl .35 3.00 L05 Freq 10.00 20.00 Accel 1.05 -35 100.00 Acel 35 35 Test Response Spectra Freq (z) 1.00 1.12 1.26 1.41 1.58 1.78 2.00 2.24 2.51 2.82 3.16 3.55 3.98 4.47 5.01 5.62 631 7.08 7.94 8.91 10.00 1122 12.59 14.13 15.85 17.78 19.95 2239 25.12 28.18 31.62 35.48 39.81 44.67 50.12 56.23 63.10 70.79 79.43 89.13 100.00 .5%Damp GPk 1.13 1.44 1.69 1.38 1.74 1.72 2.45 2-93 2.98 2.88 3.74 3.09 2.71 336 3.55 3.57 2.41 3.32 3.59 530 3.35 4.82 176 L35 2.80 2.30 1.62 2.17 133 1.63 1.63 1.25 1.05 1.32 1.94 1.02 1.03 1.62 1.89 1.48 1.78 2.0%Damp GPk .64 .87 1.28 1in 1.24 125 1.46 1.70 1.71 1.90 2.10 1.90 1.96 1.94 2-02 Z06 1.82 2.04 Z10 231 2.65 235 1.24 1.04 1.53 1.31 1.21 1.43 1.08 1.28 .97 1.00 .97 115 134 .92 .99 1.46 1.48 1.11 140 3.0%Damp GPk .53 .69 1.08 .99 103 1.06 117 1-37 1.48 L64 1.67 158 1.74 1.56 1.84 1.66 1.67 1.85 1.80 1.90 2.25 1.81 L10 1.00 1.35 L10 118 125 1.09 1.12 .93 .95 .96 1.09 1.15 .90 .96 L29 1.32 1.03 126 5.0%Damp GPk .42 .56 .81 .79 .79 .87 .85 1.08 1.12 1-34 1.20 125 136 1.25 1.55 1.40 139 1.55 1.57 1.50 1.77 134 1.02 .94 114 1.03 1.11 1.10 1.04 .97 .88 .89 .92 .98 .92 .89 .93 1.05 1.09 .98 1.07 7.0%Damp GPk 35 .47 .69 .66 .66 .75 .75 .93 .98 1.14 .95 1.07 116 1.11 135 1.28 1.19 1.35 1.43 L41 1.48 121 -92 .88 101 .98 1.05 1.05 .98 .88 .84 .85 .87 .91 .91 .89 .92 .93 .94 .96 .96 LZRPLOT Ver. 2.1n 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206001 22-12 2 :34p Accel No. 7 1/ 6 Octave ZPA: 1.33 gPk REQUIRED RESPONSE SPECTRA RRS File: Q12060BE.RRS 22-12 9:17a A C c e e a ti 0 n (91s) 25.0 10.0 7.0 5.0 3,0 2.0 1.0 .7 .5 ..=. -i-v~-r~ -v-7 -- j ~.------------- CD OD .3 .2 .I 1 2 3 4 5 6 7 8 (0 Frequency (Hertz) 20 30 40 50 60 70 80 100 LZRPLOT Ver. 2.1n 03-22-2012

Report No. EGS-TR-HC589.01 Appendix II, Page No. 23 TEST RESPONSE SPECTRA Data File: Q1206001 22-12 2:34p REQUIRED RESPONSE SPECTRA Accel No. 7 1/6 Octave ZP: 1.33 gPk RRS File: Q12060BE.RRS 22-12 9:17a Required Response Spectra Ff Accel Fre Accel Freq Accel .35 100 05 50.00 35 3.00 105 20.00 .35 100.00 .35 Test Response Spectra Freq .5%Damp 2.0%Damp 3.0%Damp 5j.%Damp 7.0%Damp Q(z0 GPk GPk GPk GPk GPk .53 .44 .40 .35 .32 1.2 1.65 1.0 .95 .73 .59 126 177 1.29 1.10 .86 .73 L41 165 .97 .86 375 .68 L58 1.89 121 1.04 .80 .66 178 1.0 L08 .90 .75 .67 2.00 2.19 1.37 1.19 .99 .86 224 2.18 L48 L27 116 L03 2.51 1.48 1,25 1.4 1L0 .92 2S82 3.30 L96 L65 1,31 1.13 3.16 4.31 2.34 L94 1.49 1.22 3.55 3.14 L78 1.53 138 1,23 3.98 3.19 2.16 L90 1L54 1.30 4.47 2.78 2.49 2.13 1.64 1.36 5.01 3.59 225 2.04 1.75 1-52 5.62 4.97 2.33 2.04 1.75 1.53 6.31 4.44 3.09 2.65 2.17 1.85 7.08 4.43 2.78 2.42 2.19 2.02 794 6.29 439 3.69 2,85 2-36 8.91 6.12 328 2.99 2.44 2.06 10.00 5.70 3.64 3.24 2.73 2.34 11.22 5.65 4.09 3.82 3.38 2-95 12.59 12A5 6.31 4.99 3.53 2.89 14.13 7.86 5.18 4.52 3.66 3.20 15.85 7.92 4.14 3.76 336 2.98 17.78 6.49 3.98 3.43 2.82 2.49 19.95 5.97 3.25 2.77 2.32 2.04 22.39 4.17 3.20 2.85 2.37 2.05 25.12 3.46 2.58 2.45 2.24 2.08 28.18 3.93 2.79 2.63 238 2.21 31-62 8.12 4.92 4.13 3.14 2.55 35.48 10.15 5.32 4.34 3.36 2.82 39.81 3.98 2.68 2.53 2,34 2-24 44.67 3.44 2.24 2.03 1.80 1.81 50.12 3.21 2.53 234 2.12 zoo 5623 2.25 1.98 1.92 L83 1.78 63.10 2.46 1.89 170 1.48 149 70.79 1.96 1.63 L53 144 1.44 79.43 2.02 1.76 1.69 1.59 1.53 89.13 2-56 1.86 L61 L43 L43 100.00 2.77 2.00 L78 1.50 L35 LZRPLOT Ver. 21n 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206001 22-12 2:34p Accel No. 8 1/6 Octave ZPA: 1.39 gPk REQUIRED RESPONSE SPECTRA RRS File: Q1206OBE.RRS 22-12 9:17a 50.0 30.0 20.0 10.0 7.0 A C c e e r a t i 0 n 5.0 3.0 2.0 S.. z + ' z 20 30..0.... 0* I 3 4 ° 5 02 0 4 0 6 08 CD ~.CA (g9s) 1.0 .7 .5 .3 .2 .1 DO Frequency (Hertz) + )o LZRPLOT Ver. 2. in 03-22-20t2

Report No. EGS-TR-HC589-01 Appendix II, Page No. 25 TEST RESPONSE SPECTRA Data File: Q1206001 22-12 2.34p Accel No. 8 1/6 Octave ZPA: 139 gPk REQUIRED RESPONSE SPECTRA RRS Filev Q1206OBERRS 22-12 9.17a Required Response Spectra Fir Accel Fre ,.8 35 10.0 3.00 105 20.00 Test Response Spectra Accel 105 .35 Fr1. 100.00 Accel 35 35 Freq .00 1.12 126 1.41 1.58 1L78 2.00 2.24 2.51 2.82 3.16 3.55 3.98 4.47 5.01 5.62 6.31 7.08 7.94 8.91 10.00 1122 12.59 14.13 15.85 17.78 19.95 2239 25.12 28.18 31.62 35.48 39.81 44.67 5012 56.23 63.10 70.79 79.43 89.13 100.00 SDamp GPk .87 1.94 L09 117 .93 1.93 170 3.34 2.58 3.42 4.61 6.13 4.41 4.50 4.98 5.70 13.07 2285 25.09 11.10 7.69 4.19 2.83 2.39 2-31 3.13 2.86 2.40 2.63 2.04 188 2.02 1.67 2.01 L95 2.61 223 2.87 2.39 2.65 2.42 2.0%Damp GPk .67 1.03 .79 .76 .81 1.32 1.21 1.78 2.20 2.31 2.48 3.08 2.52 2.51 3.83 3.42 7.83 1139 13.93 6.92 4.49 3.04 2.26 2.06 190 228 L18 192 2.03 172 1.57 163 1.45 1.65 1.71 1.91 1.90 2.33 1.86 2.16 2.03 3.0%Damp GPk .57 £86 .70 .69 .74 110 1.03 1.39 188 1.97 2.01 2.45 2.27 2.38 330 3.27 6.18 8.93 1138 6.21 4.16 2.76 2.22 2.03 1.81 212 175 1.90 1-97 1.59 1.54 152 1.43 1.56 .L62 175 1.83 2.15 184 1.97 1.89 5.0%Damp GPk .45 .67 .57 .59 .65 .84 .82 1.06 1.44 1.53 1.49 1.84 L97 2.10 2.74 3.01 5.02 7.24 8.23 5.17 3.60 2.50 2.15 L98 1.76 1.96 1.75 1.85 1.87 1.50 149 1.45 1.42 1.47 1.53 1.64 1.81 L91 1.76 1.78 1.73 7.0%Damp GPk 38 .57 .50 .52 .59 .70 .72 .94 1.15 135 L21 1.54 1-75 1.84 2.40 2.83 422 6.01 6.43 4.26 319 2.45 212 1.96 1.74 1.88 1.75 1.80 1.79 147 1.45 1.44 139 1.42 1.47 1.56 1.74 1.79 169 1.68 1.64 LZRPLOT Ver. 2.1n 0.22-2012

TEST RESPONSE SPECTRA Data File: Q1206001 22-12 2:34 p Accel No. 9 1/6 Octave ZPA: .96 gPk REQUIRED RESPONSE SPECTRA RRS File: QI206OBE.RRS 22-12 9:17a 10.0 7.0 5.0 4.0 3.0 I T [ I Z-k =. : I" J I I _ V i. 1+ w I I I I "1 I I I ~ I A C C e1 e r a t i 0n 2.0 .9 .7 i.......*

  • I hT"

]~ ~ ~ ~ ~ ~ ~~. I...--. ., t Q~CD (ges) .5 .4 .3 .2 .1 I 2 3 4 5 6 7 8 10 Frequency (Hertz) 20 30 40 50 60 70 80 100 LZRPLOT Ver. 2. In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix 11, Page No. 27 TEST RESPONSE SPECTRA Data File: Q1206001 22-12 2:34p REQUIRED RESPONSE SPECTRA AccelNo. 9 1/6 Octave ZPAT:.96 gPk RRS File: Q1206OBERRS 22-12 9:17a Required Response Spectra Freq Accel F.req Accel Freq Accel t00 35 10.00 105 50.00 .35 3.00 1.05 20.00 35 100.00 .35 Test Response Spectra Freq .5%Damp 2.0%Damp 3.0%Damp 5.0%Damp 7.0%Damp (.z) GPk GPk GPk GPk GPk .54 .44 .40 35 .32 112 L60 1.12 .97 .74 .60 1.26 1.70 1.25 1.07 .82 .69 L41 1.56 .93 .82 .73 .65 1M58 181 115 .98 .76 .63 1.78 1.48 1.07 .90 .71 .63 200 2.11 134 117 .98 .85 2.24 2.05 L40 1.29 1.15 1,02 2-51 L41 L21 112 .98 .90 2.82 3.09 1,88 1.60 1.27 L08 3.16 429 230 1.89 1.45 1.19 3.55 2.90 1.64 1.51 1.33 1.18 3.98 3.00 2.07 182 L48 1.25 4.47 2.75 2.42 2.06 1.58 130 5.01 331 211 L97 L68 146 5.62 4.41 2.07 187 1.63 L44 6.31 3.93 2.72 2.43 zoo 1.71 7.08 4.41 2.65 227 1.91 1.77 7.94 5.15 3.82 3.25 2.53 2.10 &91 5.38 2.88 2.66 2.16 1.82 10.00 4.83 3.11 2.64 2.20 1.88 11.22 4.53 3.14 2.98 2.65 232 12.59 9.50 4.81 3.81 2.68 218 1413 5.62 3.91 3.42 2.70 2.29 15.85 4.84 2.81 2.72 2.47 223 17.78 3.63 2.38 213 1.85 1.68 19.95 1.69 1.28 1.23 L22 1.22 22.39 L49 116 1.11 L07 L07 25.12 1.96 1.54 1.40 123 1.13 28.18 218 L82 1.66 1.49 1.40 3162 2.69 1.73 1.58 L47 139 35.48 4.07 238 1.99 L64 1.44 39.81 3.09 2.05 1.84 1.54 1.41 44.67 2.88 1.77 1.60 1.48 L40 50.12 310 2.38 2.13 1.77 1.53 56.23 215 1.65 1.56 1.42 135 63.10 2.65 2.01 181 1.58 L45 70.79 2.96 2,18 1.85 1.62 1.51 79.43 3.56 2.62 2.25 1.80 1.64 89.13 4.08 2.28 1.99 1.66 149 100.00 3.84 2.14 1.89 L63 1.53 LZRPLOT Ver. Z2n 03-22-2012

TEST RESPONSE SPECTRA Data Fil: Q1206001 22-12 2 :3 4p Accel No. 10 1/6 Octave ZPA: 1.44 gPk REQUIRED RESPONSE SPECTRA RRS F1ie: Q12060BE.RRS 22-12 9:17a A 25.0 10.0 7.0 5.0 ~I ~~-" L . 771 ..IU... .17- -T1.T' ... 7 Ij~ I-I I rl/ f fl I li A c C e 1 r at 0 n (g's) 3.0 2.0 1.0 .7 .5

  • I

/I I

  • --~

I" x 4 - J,7.'*........*.. '2 CD .3 .2 .1 2 3 4 5 6 7 8 10 Prequency (Hetz) 20 30 40 50 60 70 80 100 LZRPLOT Ver. 2. In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix I1, Page No. 29 TEST RESPONSE SPECTRA Data File: Q1206001 22-12 2:34p REQUIRED RESPONSE SPECTRA Accel No.10 1/6 Octave ZPA: L44 gPk RRS File: Q12060BERRS 22-12 9-17a Required Response Spectra Freq Accel Freq Accel Freq Accel .35 10.00 1.05 50.00 35 3.00 1.05 20.00 .35 100.00 .35 Test Response Spectra Freq 5%Damp 2.0%Damp 3.0%Damp 5.0%Damp 7.0%Damp (hz GPk GPk GPk GPk GPk .86 .66 .57 .45 .37 1.12 1.93 1.03 86 .68 .57 1.26 L09 .78 .70 .56 .49 1.41 1.21 .74 .66 .57 .50 1.58 .91 .79 .73 .64 .58 1.78 1.93 133 1U0 .84 .70 2.00 1.69 119 L1. .80 .69 2.24 333 177 1.38 1.04 .89 2.51 2.52 2.18 1.87 1.43 115 2.82 326 2.20 L88 L47 131 3.16 4.40 2.35 L90 L41 1.14 3.55 5.96 2.98 2.33 L75 L45 3.98 4.17 234 2.13 L84 163 4.47 4.23 2.35 2.18 1.92 L69 5.01 4.50 3.50 3.02 2.50 2.12 5.62 4.96 3.01 2.66 2.49 2.34 6.31 11.00 6.54 5.18 419 3.52 7.08 18.42 9.24 715 5.65 4.70 7.94 19.43 10.65 &72 632 4.95 8.91 8.34 5.27 4.66 3.90 3.23 10.00 5.51 3.31 3.00 2.60 2.30 1122 3.08 2.11 L98 1.86 1.81 12.59 2.05 1.75 L71 168 1.66 14.13 2.29 2.03 1.90 1.76 1.67 15.85 2.29 183 1.72 1.63 L58 17.78 2.58 1.87 1.77 1.65 163 19.95 3.00 1.98 182 1.72 1.66 22.39 3.72 2.19 L90 1.64 1.50 25.12 2.41 185 L71 1.51 L40 28.18 2.52 1.68 159 1.51 146 31.62 2.42 L71 1.69 1.62 1.55 35.48 3.09 2.09 186 1.58 1.51 39.81 2.43 L72 161 154 1.51 44.67 2.44 2.26 2.20 2.08 L97 50.12 2.82 295 2.81 2.54 234 56.23 323 2.56 2.36 228 2.26 63.10 4.57 3.63 3.27 2.89 2.66 70.79 7.24 433 3.72 3.21 2.86 79.43 9.88 5.07 4-34 3.52 3.01 89.13 10.06 6.59 5.60 4.44 3.74 100.00 1032 5.67 4.91 3.76 3.27 LZRPLOT Ver. 2.1n 03-22-2012

TEST RESPONSE SPECTrRA Data File: Q1206001 22-12 2:34p Accel No. I1 1/ 6 Octave ZPA: 1.05 gPk A C C e I e r a ti 0 n (g's) 10.0 7.0 5.0 4.0 3.0 2.0 .9 .7 .5 .4 .3 .2 .1 I NJ IN .I n.. im o REQUIRED RESPONSE SPECTRA RRS FMe: Q1206OBE.RRS 22-12 9:17a I I l ! : t I 2 3 4 5 6 7 8 10 20 30 40 50 60 70 80 100 FTequency (Hertz) LZRPLOT Ver. 2.1n 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 31 TEST RESPONSE SPECTRA Data File: Q1206001 22-12 2:34p Accel No.11 1/6 Octave ZPA: 1.05 gPk REQUIRED RESPONSE SPECTRA RRS File: Q1206OBF.RRS 22-12 9:17a Required Response Spectra Fr. Accel Frq .35 10. 3.00 L05 20.00 Test Response Spectra Accel L05 .35 Freq 50.00 100.00 Accel 35 .35 Freq 122 1.26 1.41 L58 1.78 2.00 224 2.51 2.82 3.16 355 3.98 4.47 5.01 5.62 631 7.08 7.94 &91 1100 1259 1413 15.85 17.78 19.95 22.39 25.12 28.18 31.62 35.48 3981 44.67 5012 56.23 63.10 70.79 79.43 89.13 100.00 .5%Damp GPk L06 1.38 L56 1.26 1.69 L64 229 2.62 2.86 2.68 3.64 2.90 2.58 3.26 3.43 3.38 253 3.31 326 5.07 3.25 4.58 1.81 1.36 2.28 1.88 135 2.14 2.16 2.52 2.12 1.74 1.49 1.97 1.74 2.88 3.42 2.91 3.97 5.23 5.36 2.0%Damp GPk .60 .82 119 L03 1.19 1.19 137 1.55 1.57 1.82 2.oo 1.69 1.80 1.89 1.83 1.94 1.83 2.02 1.94 2.30 2.47 2.17 1.24 .97 132 1.20 129 1.47 1.42 L69 1.25 116 1.45 1.57 1.52 2.41 3.05 2.55 2.81 4.86 3.91 3.0%Damp GPk A9 .67 1.01 .91 .98 L01 1.10 1.27 1.36 1.58 1.59 1.42 1.62 1.53 1.67 1.57 1.68 1.77 164 187 2.09 L67 1.09 .94 1.8 L08 122 128 L25 1.46 113 1.14 132 [44 L41 220 2.79 2.32 2-58 4.47 3.58 5.0%Damp GPk .40 .54 .76 .74 .75 .81 .80 .99 1.10 1.28 1.4 1.20 1.28 1.17 1.41 1.24 1.41 1.45 132 [49 1.63 121 .97 .£7 1.01 .98 1.12 1.18 1.09 1.24 1.08 1.07 1.17 1.28 1.26 1.85 238 1.98 2.32 3.74 3.12 7.0%Damp GPk .33 .45 .66 .62 .62 .70 .72 .85 .95 [09 .92 103 1,11 1.04 1.22 1.15 L19 125 1.18 1.27 1.36 1.12 £9 .81 .90 .92 1.04 1.10 1.04 1.10 1.04 1.02 1.07 1.19 1.17 1.67 2.06 1.81 2.15 320 2.78 LZRPLOT Ver. 21n 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206002 22-12 2:36p Accel No. 1 116 Octave ZPA: .53 gPk REQUIRED RESPONSE SPECTRA RRS Pde: Q12060BE.RRS 22-12 9:17a 5.0 4.0 3.0 2.0 A c C e 1.0 1 r .8 a t i .6 0 n .5 (g9s) .4 .3 .2 .I f IN 1 i .f; 4 5 7 8 10 20 30 40 50 60 70 80 1C Frequency (Hertz) 'Z 10 LZRPLOT Ver. 2. In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 33 TEST RESPONSE SPECTRA Data File: Q1206002 22-12 2:36 p REQUIRED RESPONSE SPECTRA Accel No. 1 1/6 Octave ZPA .53 gPk RRS File: Q1206OBERRS 22-12 9-17a Required Response Spectra Fre Accel Freq Accel F.re Accel .35 10.00 1.05

50.

35 3.00 105 2000 .35 100.00 .35 Test Response Spectra Freq .5%Damnp 2.0%Damp 3.0%Damp 5.0%Damp 7.0%Damp (h.) GPk GPk GPk GPk GPk .54 .45 .41 .36 .32 1.12 L62 10 .96 .73 .60 1.26 L72 127 I108 .84 .70 1.41 L59 .95 .84 .74 .66 158 1.82 1.15 -98 .77 .64 178 1.46 L04 .88 .71 .63 2.00 2.07 132 1.14 .95 .83 2.24 2.03 L40 122 L10 .97 2.51 1.31 1.16 L08 .94 .87 2.82 3.07 L82 1.53 120 1.05 3-16 3.83 2.17 1.79 137 12 3.55 2.70 1.54 1.37 125 I1 3.98 2.83 1.93 170 1.38 1.16 4.47 2.56 2.23 1.90 1.45 119 5.01 2-94 L90 1.73 L42 122 5.62 3.85 1.82 1.58 137 1.24 6.31 3.44 234 2.07 1.69 1.44 7.08 3.38 2B3 1.85 1.52 130 7.94 3.92 2.89 2.44 1.89 L56 8.91 3.73 190 L71 L44 1.26 10.00 2.8 1.95 165 128 1.08 11.22 2A5 137 120 Ll .99 12.59 3.78 1.91 L55 1.14 .93 14.13 L79 121 L08 .92 .81 15.85 1-37 101 .92 .84 .78 17.78 2.09 1.22 1.08 .92 .82 19.95 2.03 1.05 .94 .79 .72 22.39 139 .88 .83 .74 .69 25.12 1.01 .83 .76 .71 .67 28.18 .86 .71 .69 .67 .65 3162 1.02 .84 .78 .71 .68 35.48 .74 .66 .66 .64 .62 39.81 .67 .62 .61 .60 .60 44.67 .66 .65 .64 .63 .61 50.12 .62 .59 59 .60 .60 56.23 .72 .71 .68 .65 .63 6310 .74 .65 .63 .61 .59 70.79 .73 .63 .60 .57 .55 79.43 .69 .59 -57 .55 .54 89.13 .64 .58 .57 .56 .55 100.00 .69 .59 .58 .57 .56 LZRPLOT Ver. 2.1n 03-22-2012

TEST RESPONSE SPECTRA Data Mie: Q1206002 22-12 2 :36p Accel No. 2 1/6 Octave ZPA: .67 gPk REQUIRED RESPONSE SPECTRA RRS Fil: QI206OBE.RRS 22-12 9:17a 10.0 7.0 5.0 4.0 3.0 I1 N ! A 2.0 c c 1e a t .9 i 0 .7 (g's) .5 .4 .3 .2 .I A_ I 40lx 0 0 C

  • 0 r_

)o Frequency (Hertz) LZRPLOT Vet. 2.In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 35 TEST RESPONSE SPECTRA Data File: Q1206002 22-12 2:36p REQUIRED RESPONSE SPECTRA Accel No. 2 1/6 Octave ZPA..67 gPk RRS File QI2O6OBF-RRS 22-12 917a Required Response Spectra Fre_ Accel Freq Accel Fre Accel .35 10.00 1.05 50DO 35 3.00 1.05 20.00 35 100.00 .35 Test Response Spectra Freq 5%Damp 10%Damp 3.0%Damp 5.0%Damp 7.0%Damp (.z0 GPk GPk GPk GPk GPk S.84 .64 .55 .44 36 L12 1.89 .95 .80 .63 .53 126 108 .78 .66 .52 .46 1.41 117 .72 .61 .52 .46 1.58 85 .71 .66 .58 .53 1.78 1.78 1.21 .99 .76 .63 2.00 1.55 i1 .95 .76 .64 2.24 3.05 1.61 L26 .96 .80 2.51 2.20 L97 L71 133 1.07 2.82 2.83 L83 1.54 1.24 1.09 3.16 3.61 1.96 1.55 1.13 .92 3.55 4.92 2.47 L90 1.38 1.14 3.98 3.15 1.77 1.53 L31 1.15 4.47 2.86 1.76 152 1.30 114 5.01 2.81 2.26 L94 1.57 1.33 5.62 2.39 1.43 132 1.23 113 631 4.09 2.35 191 140 1.14 7.08 4.54 2.54 2.06 152 1.23 7.94 3.21 2.19 188 1.48 122 8.91 3.18 189 1.68 1.40 1.21 10.00 3.61 1.90 1.52 123 110 1122 2.52 1.42 125 L04 .91 12.59 1.71 1.33 L25 L14 1.07 14.13 235 1.55 L47 L33 1.24 15.85 3.03 179 L67 1.47 1.34 17.78 5.22 3.26 2.75 216 1.77 19.95 4.87 2.71 2.34 L91 1.62 2239 2.39 171 1.53 132 1.19 25.12 1.43 1.04 1t0 .96 .92 28.18 1.27 1.14 1.12 1.06 1.02 31.62 1.08 1.00 .99 .97 .95 35.48 95 .78 .79 .80 .81 39.81 .91 .77 .77 .76 .76 44.67 .74 .65 .65 .66 .67 50.12 .73 .66 .67 .67 .68 5623 88 S1 .79 .77 .75 63.10 .78 .75 .76 .76 .75 70.79 .76 .74 .74 .74 .73 79.43 .74 .71 .71 .70 .70 89.1 .75 .71 .70 .70 .70 100.00 .71 .70 .70 .71 .71 LZRPLOT Ver. 2.1n 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206002 22-12 2 :36p Accel No. 3 1/6 Octave ZPA: .58 gPk REQUIRED RESPONSE SPECTRA RRS File: Q1206OBE.RRS 22-12 9:17a 5.0 4.0 3.0 2.0 A c e1 r a ti 0 n 1.0 .8 .6 .5 .,.7.- L. i " X' M (g's) .4 .3 .2 .1.. ..... L. I I .4..., ~.Li..7.7.1 .1 1 i i i i i I 2 3 4 8 10 Frequency (Hertz) 20 30 40 50 60 70 80 100 LZRPLOT Vet. 2. in 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 37 TEST RESPONSE SPECTRA Data File: Q1206002 22-12 2:36p Accel No. 3 1/6 Octave ZPA: .58 gPk Rcquired Response Spectra REQUIRED RESPONSE SPECTRA RRS Film Q12060BE.RRS 22412 9:17a Freq 100 3.00 Accel .35 1.05 Fr2 20.00 Accel 1.05 .35 Freq 50.00 100.00 Accel .35 35 Test Response Spectra Freq 1.12 1.26 1.41 1.58 1.78 2.00 2.24 251 2.82 3.16 355 398 4.47 5.01 5.62 6-31 7.08 7.94 8.91 10.00 11.22 12.59 14.13 15.85 17.78 19.95 22.39 25.12 2818 31.62 35.48 39.81 44.67 50.12 5623 63.10 70.79 79.43 89.13 100.00 .5%Damp GPk 99 1.32 1.53 123 1.63 1.56 2.30 2.65 2.79 2.70 3.54 2.89 246 320 3.33 327 228 2.95 323 4.70 2.87 4.16 1.47 109 1.71 1.47 1.36 188 1.96 1.96 1-32 1.12 .91 .92 .81 .87 .80 .72 .77 .77 .74 2.0%Damp GPk -56 .78 1.17 1.01 1.15 1.15 136 1.55 1.56 1.78 L97 1.75 1.84 1.82 1.80 1.91 1.74 L92 1.95 2.09 2.26 2.09 1.11 .87 1.02 .97 .14 1.26 1.19 134 .98 .91 .94 .92 .83 .87 .74 .70 .71 .69 .62 3.0%Damp GPk .46 .64 .99 .90 .96 .98 108 1.27 1.35 1.54 1.57 .48 L64 1.46 1.65 1.55 1.56 1.73 1.57 L73 1-92 1.63 1.02 .83 .92 .91 L07 1.07 1.03 1.15 .91 .90 92 .91 .83 .85 .71 .69 .69 .68 .62 5.0%Damp GPk 37 .51 .74 .73 .72 .80 .79 .99 1.04 1.25 1.13 118 129 116 1.40 1.25 1.29 1.44 1.36 137 1.50 1.20 .92 .75 80 .84 98 .99 .88 .93 80 .87 .88 .87 £81 .80 .68 .67 .67 .66 .62 7.0%Damp GPk .31 43 .65 .61 .60 .69 .69 .85 .92 1.06 .91 1.02 1.08 1.03 1.22 115 L12 L25 1.24 1.23 1.25 1.12 £7 .73 .72 .79 .91 .93 .85 .84 .79 .84 £5 .84 .80 .77 .66 .66 .66 .65 .62 LZRPLOT Ver. 2-1n 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206002 22-12 2:36p Accel No. 4 I/6 Octave ZPA: 1.10 gPk REQUIRED RESPONSE SPECTRA RRS Pile: Q1206OBE.RRS 22-12 9:17a 25.0 10.0 7.0 5.0 3.0 2.0 1.0 I- : 'iT TTWTTTTF

~ I IIZII~I2 1ZI....~ t

~Z~~ZZ ~I4Ij IZVflII4T1I 1-1-1-4 1-HAHJ + - A c c e 1 e r a ti 0 n 0.1 oý P 10 oo -10

o4f, MIDm ZG aý (g's)

.7 .5 .3 .2 .1 1 2 Fr4u5c6 7 8 10 Fre~quency (Hertz) 20 30 40 50 60 70 80 100 LZRPLOT Vet. 2. in 03.-22-2012

Report No. EGS-TR-HC589MC1 Appendix II, Page No. 39 TEST RESPONSE SPECTRA Data File: Q1206002 22-12 2:36p REQUIRED RESPONSE SPECTRA Accel No. 4 1/6 Octave ZPA: 10 gPk RRS File: Q126OBE.RRS 22-12 9.17a Required Response Spectra Freq Accel Freq Accel Freq Accel L00 .35 10.00 L05 50.00 .35 3.00 1.05 20.00 .35 100.00 .35 Test Response Spectra Freq 5%Damp 2.0%Damp 3.0%Damp 5.0%Damp 7.0%Damp (hz) OPk OPk GPk GPk GPk 1.00 .59 .49 .44 .38 .34 112 1-56 112 .97 .75 .61 126 1.78 1.31 132 .87 .73 1.41 1.69 L01 .89 .78 .70 1.58 1.94 17 1.02 .82 .68 1.78 1.57 L09 .92 .73 .64 2.00 2.07 1.31 114 .97 .86 2.24 2.14 1.44 1.26 1.13 .99 2.51 1.54 127 1.13 .97 .89 2.82 3.29 1.94 1.62 1.29 112 316 4.22 2.36 1.94 L49 1.23 355 3.03 1.78 1.58 1.38 123 3.98 3.32 2.12 1.85 1.50 L27 4.47 2.76 2.49 2.14 1.67 140 5.01 3.55 2.22 2.08 1.78 1.55 5.62 4.85 2.30 2.01 1.74 L52 6.31 4.13 2.96 2.66 2.21 1.90 7.08 5.13 3.03 2.59 2.09 1.92 7.94 5.81 431 3.65 2.83 2.34 8.91 6.17 327 2.91 2.36 2.00 10.00 5.47 3.57 3.02 2.58 2.24 11.22 5.60 381 3.59 323 2.84 12.59 13.58 6.77 52.1 3.70 2.89 14.13 7.76 5.48 4.72 3.67 3.18 15.85 6.08 427 412 3.68 326 17.78 6.16 3.60 3.06 2.62 2.35 19.95 3.07 2.10 197 1.78 1.66 22.39 1.91 1.56 L48 1.42 1.38 25.12 L94 1.64 1.53 1.41 1.34 2818 1.95 1.47 1.41 135 1.31 3L62 L71 L44 1.42 L40 1.38 35.48 2.66 191 1.78 L62 1.52 39.81 223 169 1.57 1.48 1.41 44.67 1.68 147 1.47 1.39 1-32 50-12 2.78 L70 139 L23 1.19 56.23 1.86 1.45 1.39 1.31 1.25 6310 2.15 1.54 1.43 134 1.29 70.79 2.88 1.77 1.65 1.48 1.40 79.43 3.51 214 1.91 1.70 1.61 89.13 3.22 2.33 L96 1.81 1.69 100.00 2.oo L77 1.71 1.59 1.51 LZRPLOT Ver. 2.1n 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206002 22-12 2 :36 p Accel No. 5 1/6 Octave ZPA: 1.65 gPk REQUIRED RESPONSE SPECTRA RRS File: Q1206OBE.RRS 22-12 9:17a 50.0 -Z L. I I 30.0 20.0 10.0 7.0 A C C e e r a t i 0 5.0 3.0 2.0 -A 77, -~{~.41.7 1~ I ~~~~T .1 1 ip Sm 0G n (g's) 1.0 .7 .5 .3 .2 .1 2 3rqu5c6 7 8 10 Frequency (Hertz) 20 30 40 50 60 70 80 100 LZRPLOT Ver. 2. In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 41 TEST RESPONSE SPECTRA Data File: Q1206002 22-12 2:36p REQUIRED RESPONSE SPECTRA Accel No. 5 1/6 Octave ZPA: L65 gPk RRS File: Q1206OBE.RRS 22-12 9-17a Required Response Spectra Fr Accel Freq Accel .req Accel .35 10.00 105 50.00 .35 3.00 1.05 20.00 .35 100.00 35 Test Response Spectra Freq -,oDamp 2.0%Damp 3.0%Damp 5.0%Damp 7.0%Damp GPk GPk GPk GPk GPk .88 .68 .58 .45 38 1.12 L96 1.02 .86 .67 .57 126 110 .78 .70 .55 .48 1.41 127 .76 .65 .56 .50 158 .97 .78 .72 .64 .58 1.78 197 136 .13 .88 .74 2.00 1.75 125 1.07 .85 .74 2.24 339 L83 1.43 1.09 .96 2.51 2.66 2.28 192 L46 118 2.82 3.57 2.42 2.07 L60 1-39 316 4.70 256 2.08 1.55 125 3.55 6.42 3.25 2.60 L92 L61 3.98 4.52 2.64 2.35 2.04 1.81 4.47 4.61 2.64 2.44 2.15 191 5.01 532 3.97 3.41 287 2.61 5.62 5.75 3.66 3.56 3.26 3.10 6.31 14.51 855 6.95 5.62 4.73 7.08 2533 12.58 1010 8.24 6.84 7.94 27.08 14.82 12.16 8.8 6.89 &91 12.73 7.55 7.07 5.86 4.1 10.00 8.91 5.06 4.49 3.85 3.39 T122 4.92 336 3.09 2.85 2.78 12.59 337 2.55 2.48 2.47 2.43 14.13 3.08 2.68 2.58 2.46 2.39 15.85 3.69 2.76 2.62 2.43 2.31 17.78 3.86 2.99 2.83 2.63 2.51 19.95 4.00 277 2.58 2.42 240 2239 2-73 2-52 2.55 2.49 2.42 2512 4.19 2.70 2.49 2.29 2.21 28.18 535 330 2.77 225 1-22 31.62 3.58 2.59 2.25 2.15 207 35.48 3.98 2.79 2.50 221 2.07 39.1 2.94 2.21 2.06 1.93 L88 44.67 2.76 2.15 2.14 2.09 2.04 5012 2.34 2.20 219 2-13 2.07 5623 Z95 2.47 2.32 2.17 2.08 6310 2.41 2.19 2.13 2.06 2.00 70.79 1.86 1.83 1.83 1.82 1.83 79.43 311 258 2.42 2-20 2.07 8913 2.60 2.50 237 2.19 2.06 100.00 2.56 199 1.95 1.90 1.86 LZRPLOT Ver. 2.1n 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206002 22-12 2 :3 6 p Accel No. 6 116 Octave ZPA: REQUIRED RESPONSE SPECTRA RRS File: Q12060BE.RRS 22-12 9:17a .76 gPk 10.0 7.0 5.0 4.0 3.0 2.0 .9 .7 TA I A c c 1 e r at i 0 n . 7 7 I I I [A F 7771 /N -1 [ITT,....

1.

.1 Jill I A 9 A 17 2 in In 2A AA 1qA OZA 'M QA mZ 6 (g's) .5 .4 .3 .2 .1 Frequency (Hertz) .#V .sV W

'*dr fdb*
  • W LZRPLOT Ver. 2.In 03-22-2012

Report No. EGS-TR-HC589MI1 Appendix I1, Page No. 43 TEST RESPONSE SPECTRA Data File: Q1206002 22-12 2:36p Accel No. 6 1/6 Octave ZPA. .76 gPk REQUIRED RESPONSE SPECTRA RRS File: Q1206OBERRS 22-12 9.17a Required Response Spectra PFr Accel Freq 1 .235 10.00 3.00 105 20.00 Test Response Spectra Accel 1.05 35 100.00 Accel 35 35 Freq L12 1.26 1.41 158 1.78 2.00 2.24 2.51 2.82 316 3.55 3.98 4.47 5.01 5.62 6.31 7.08 7.94 &91 10.00 1122 1259 1413 15.5 17.78 19.95 22.39 25.12 28.18 31.62 35.48 39.81 44.67 5012 5623 63-10 70.79 79.43 89.13 100.00 .5%Damp GPk 112 1.45 L68 134 L77 L70 2.45 228" 2.97 290 3.74 3.06 2.65 3.36 3.53 3.52 250 3.26 3.53 5.19 332 4.77 1.76 1.45 284 2.23 1.73 232 1.43 1.83 L66 1.11 L04 1.46 1.62 110 ws 153 2.10 1.41 1.47 2.0%Damp OPk .63 .88 1.27 1.09 126 125 L46 1.68 1.70 190 2.09 1.87 L98 L93 1.97 2.04 1.85 2.02 2.15 2.28 2.60 232 1.26 L05 1.57 132 1.26 L55 107 129 .96 .93 .86 1.19 1.23 .93 S3 1.39 1.60 1.15 1.04 3.0%Damp GPk .52 .71 108 .97 1.04 1.06 1.16 1.36 1.47 1.63 1.66 1.56 L76 1.55 1.80 L66 167 1.84 177 1.88 2.21 1.79 1.13 L02 138 1.12 1.21 132 1.08 1.14 .85 .90 .80 1.09 1.07 90 .78 1.22 1.37 L06 .95 5.0%Damp GPk .41 .55 .81 .78 .79 .87 .84 1.07 1.12 133 1.19 1.24 1.37 126 1.52 1.37 L39 1.54 1.54 1.49 1.73 1.35 1.01 .94 1.16 1.03 L14 1.10 L03 .94 .78 .84 .75 .93 .89 .87 .80 1.01 1.11 .91 .89 7.U%Damp GPk 35 .46 .69 .65 .65 .75 .75 .92 .97 1.3 .94 1.07 115 U2 1.32 1.25 121 134 L41 138 1.45 1.20 .93 .87 1.02 .99 1.07 1.05 .98 .87 .77 .80 .72 .81 .82 85 .81 .87 .95 .89 .88 LZRPLOT Ver. Zn 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206002 22-12 2:36p Accel No. 7 1/6 Octave ZPA: 1.30 gPk REQUIRED RESPONSE SPECTRA RRS File: Q1206OBE.RRS 22-12 9:17a 25.0 10.0 7.0 5.0 E~EHIFI I ~ - F 11 Jj.H A C C T a ti 0 n 3.0 2.0 1.0 I, I PL xi ? _I 22....... 2 33 23 4 5 678 10 20 30 40 50 60 7080 1C m o 0 (g1s) .7 .5 .3 .2 .1 I )0 Frequency (Hertz) LZRPLOT Ver. 2. In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 45 TEST RESPONSE SPECTRA Data File: Q1206002 22-12 2.:36p REQUIRED RESPONSE SPECTRA Accel No. 7 1/ 6 Octave ZPA. 1.30 gPk RRS File: Q1206OBE.RRS 22-12 9-17a Required Response Spectra Fre. Accel Fre Accel Fr Accel 0.35 100 05 50.0 .35 3.00 1.05 20.00 .35 100.00 .35 Test Response Spectra Freq .5%Damp 2.0%Damp 3.0%Damp 5.0%Damp 7.0%Damp z0 GPk GPk GPk GPk GPk .54 .5 .40 35 31 1.12 1.67 Lll .95 73 .59 L26 L74 1.28 1.09 .86 .73 141 1.63 .97 .85 .75 .68 1.58 1.88 120 1.03 .80 .66 1.78 1.53 1.08 .90 .74 .66 2.00 2.20 138 120 1.00 .86 2.24 2.13 1.46 128 116 1.03 2.51 145 126 1.15 1.00 .92 2.82 3.27 1.95 1.65 1.31 113 3.16 4-13 2.34 1.94 1.49 1.23 3.55 3.04 L74 1.50 1.35 1.21 3.98 3.18 2.10 1.85 1.50 1.27 4.47 2.75 244 2.08 1.61 134 5.01 3.57 2.19 2.03 174 1.52 5.62 4.97 2.36 2.05 L76 1-53 6.31 4.37 3.06 2,69 2.21 1.89 7.08 4.43 2.81 2.46 2.12 1.97 7.94 6.33 4.43 3.72 2.86 2.36 8.91 6.15 3.26 2.85 2.32 2.02 10.00 5.62 3.61 310 2.64 2.28 1122 5.81 3.93 3.59 3.24 2.85 12.59 13.92 6.94 5.38 3.83 3.03 14.13 7.92 5.52 4.75 3.79 329 15.85 6.55 4.48 423 3.69 3.22 17.78 6.30 3.94 3.42 2.88 2.55 19.95 5.43 322 2.79 225 1.98 22.39 4.19 3.22 2.81 2.29 1.95 2512 3.26 2.38 2.16 1.95 1.83 2&18 4.03 2.72 2.56 2.20 1.91 31.62 1014 5.66 4.60 339 2.69 35.48 1010 5.59 4.53 338 2.93 39.81 3.87 258 2.47 2.28 2.20 44.67 3.24 2.38 219 1.97 1.86 5012 311 2.38 223 2.07 L98 5623 2.83 223 2.11 1.98 1.91 63.10 2.43 1.87 L84 1.78 1.75 70.79 1.90 1.78 1.71 1.65 L63 79.43 222 1.74 L68 1.61 1.59 89.13 3.10 185 170 1.61 1.61 100.0f 3.33 2.45 2.11 1.72 1.62 LZRPLOT Ver. 2.1n 03-22-2012

TEST RESPONSE SPECTRA Data Mle: Q1206002 22-12 2 :3 6p Accel No. 8 1/6 Octave ZPA: 1.37 gPk REQUIRED RESPONSE SPECTRA RRS Pile: Q1206OBE.RRS 22-12 9-.17a 25.0 I I.....t4A4. "44.4 A c c 1 e r a t i n 10.0 7.0 5.0 3.0 2.0 1.0 t- _~ I Z 1- --- - I--i I J. 11 A 4 17 2 A 2n A nan Sm Co - (g's) .7 .5 .3 .2 .1 I TWt U &ltj

  • vV

,.JV J.W rvequency (Hertz) LZRPLOT Vet. 2. in 03-22-2012

Rc~art No. EGS-TR-HC589-01 Appendix II, Page No. 47 TEST RESPONSE SPECTRA Data File; Q1206002 22-12 2:36p Accel No. 8 1/6 Octave ZPA. 137 gPk Required Response Spectra REQUIRED RESPONSE SPECTRA RRS File: Q12060BE.RRS 22-12 9%7a Fre Accel 30 1.35 3.00 1.05 Fr 20.00 Accel .05 _35 100.00 Accel .35 35 Test Response Spectra Freq 112 126 1.41 1.58 1.78 2-00 2.24 2.51 2.82 3.16 3.55 3.98 4.47 5.01 5.62 631 7.08 7.94 8.91 10.00 11.22 12.59 14.13 15.85 17.78 19.95 22-39 2512 2&18 31.62 35.48 39.1 44.67 5012 56.23 63.10 70.79 79.43 89.13 100.00 .5%Damp GPk .86 1.94 1.09 1.21 .92 1993 1.72 3.34 2-58 3.45 4.53 622 443 4.42 5.06 5.51 13.43 23.13 24.50 11.32 7.89 4.06 2.68 2.42 2.24 3.39 2-65 2.48 2.39 211 196 2.01 170 1.90 L77 2.44 2.43 2.76 2.23 2.57 2.26 10%Damp GPk .67 1.04 .79 .75 .79 132 121 1.76 2.21 2.33 2.46 3.13 2.55 2.52 3.84 3.42 7.89 11.49 1326 6.63 4.48 2.94 2.29 2.03 197 2.45 L91 197 2.03 172 1.63 1.64 160 1.62 168 1.82 1.93 2-07 1.79 2.16 1.81 3I0%Damp GPk -57 S7 .70 .68 .73 1.09 1.03 1.39 1.88 1.98 1.99 2.50 226 235 3.28 3.31 637 9.13 10.88 6.29 4.06 2.67 226 2.02 184 2.20 1.85 1.95 1.98 1.63 156 1.56 1.56 154 1.7 1.71 181 2.00 1.76 1-99 1.70 5.0%Damp GPk .45 .68 .56 .58 .64 .84 .82 L06 1.43 1.54 1.48 1.85 1.96 2.07 2.70 3.02 5:15 7.40 7.9 5.20 3.49 7-54 2.19 198 L78 L99 179 188 1.88 1.53 149 1.47 151 1.45 1.61 1.65 1.70 188 1.75 1.75 158 7.0%Damp GPk .38 .57 .49 .52 58 .70 .72 .95 1.5 134 120 1.55 1.74 1.81 2.41 2.84 433 6.15 6.16 4.27 3.08 2.50 2.15 1.97 L77 191 1.78 1.82 1.80 .48 1.44 1.44 1.48 1.44 1.56 1.60 1.61 1.80 1.72 1.68 1.58 LZRPLOT Ver. 2.1n 03-22-2012

TEST RESPONSE SPECTRA Data Ple: Q1206002 22-12 2:36p Accel No. 9 1/6 Octave ZPA: 1.04 gPk REQUIRED RESPONSE SPECTRA RRS File: Q1206OBE.RRS 22-12 9:17a 25.0 10.0 7.0 5.0 A c C e r at 0n 3.0 2.0 1.0 -- -t V1 -- -I A. '~ A_ ....... ~~~~~~~~~. .?.!. 4 020 30 40 50 6070 80 iC Frequency (Hertz) 0 6 (g's) .7 ,5 .3 .2 -I a0 LZRPLOT Ver. 2.In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 49 TEST RESPONSE SPECTRA Data File: Q1206002 22-12 2.36p REQUIRED RESPONSE SPECTRA Accel No. 9 1/6 Octave ZPA: 1.04 gPk RRS File: Q1206OBE.RRS 22-12 9.17a Required Response Spectra Frq Accel Freq Accel Freq Accel .35 10.00 L05 50.00 .35 3.00 105 20.00 .35 100.00 .35 Test Response Spectra Freq .5%Damp 2.0%Damp 3.0%Damp 5.0%Damp 7.0%Damp (h0) GPk GPk GPk GPk GPk .52 .44 .40 35 32 L12 1.59 L10 .95 .73 .59 126 L68 1.25 L06 .84 .71 L41 1-56 .93 .82 .72 .65 L58 1.82 113 .96 .76 .63 L78 1.50 L08 .90 .71 .63 2.00 2.05 131 U14 .95 .83 2.24 2.02 138 1.27 1.13 .99 251 1.41 1.20 1.09 .96 .88 2.82 310 1.85 1.57 125 .07 3.16 4.10 229 1-89 L44 1119 3.55 2.84 1,62 1.51 1.33 1.18 3.98 2.97 2.02 1.78 1.45 1.23 447 2.73 2.39 2-04 1.56 130 5.01 3.27 2.09 1.96 1.67 L46 5.62 4.42 2.07 1.86 1.61 1.43 6-31 3.87 2.74 2.46 2.03 1.74 7.08 4.47 2.68 2.30 1.87 1.74 7.94 5.16 3.84 326 2.54 2.10 8.91 537 2.80 2.54 2.06 1.75 10.00 4.74 3.08 2-54 2.14 1.84 IL22 4.68 3.04 2.85. 2.57 2.26 12.59 10.61 5.26 4.15 2.96 232 14.13 5.91 4.16 3.59 2.83 2.34 15.85 4.08 .11 2.97 2.65 2-36 17.78 3.55 2.43 2.19 1.93 1.76 19.95 1.55 132 1.26 1.28 1.26 22.39 1.52 1.18 1.11 1.06 1.05 25.12 2-08 129 L22 1.16 1M1 28.18 2.38 200 1.80 1.57 145 31.62 2.40 1.78 1.68 1-53 1.43 35.48 4.59 2.85 237 L89 1.66 39.81 2.79 1.91 1.72 1.49 1.38 44.67 2.71 1.86 L69 159 1.54 5012 3.43 2.55 2.25 183 1.60 56.23 222 181 1.65 L46 1.38 6310 2.59 1.80 1.55 1.37 L28 70.79 2.92 2.06 1.78 138 1.24 79.43 2.99 220 1.96 1.61 1.43 89.13 3.24 2.06 1.77 154 1.41 100.00 3.04 203 1.82 L.58 1.42 LZRPLOT Ver. 2,n 0-3-22-2012

TEST RESPONSE SPECTRA Data File: Q1206002 22-12 2:36p Accel No. 10 1/6 Octave ZPA: 1.47 gPk REQUIRED RESPONSE SPECTRA RRS File: Q1206OBE.RRS 22-12 9:17a 25.0 10.0 7.0 5.0 3.0 2.0 1.0 A c c e e r a t i 0 n S..' 7*. ..-]. o. I J imi.

l.

...A.. cLl ~CD (g9s) .7 .5 .3 .2 .1 1 2 3 4 5 6 7 8 10 Frequency (Hertz) 20 30 40 50 60 70 80 100 LZRPLOT Ver. 2.1n 03-22-2012

Report No. EGS-TR-HC589-01 Appendix 11, Page No. 51 TEST RESPONSE SPECTRA Data File: Q1206002 22-12 2:36p Accel No. 10 1/6 Octave ZPA: 1.47 gPk Required Response Spectra REQUIRED RESPONSE SPECTRA RRS File: Q1206OBE.RRS 22-12 9.17a Fr.0 3.00 Accel .35 1.05 Fr 20.00 Accel LOS .35 Freq 50.00 100.00 Accel 35 35 Test Response Spectra Freq 1.12 126 L41 .1.58 1.78 2.00 2.24 2.51 2.82 316 3.55 3.98 4.47 5.01 5.62 631 7.08 7.94 8.91 10.00 1L22 12.59 1413 15.85 17.78 19.95 22.39 25.12 28.18 3162 35.48 39.81 44.67 50.12 5623 6310 70.79 79.43 89.13 100.00 .5%Damp GPk .6 L94 1.09 L22 .91 L94 1.71 338 2.54 3.27 4.36 6.02 4.16 4.16 4.51 4.81 1133 18.61 '.90 857 5.66 2.98 2.09 2.15 221 2.54 329 3.90 2.66 2-32 2.01 2.71 1.97 2.85 2.76 3.14 4.14

  • 6.79 8.09 7.02 9-55 2.0%Damp GPk

.66 1.03 .79 .75 .80 132 L20 I80 2.18 221 233 3.00 2.36 2.34 3.50 3.01 6.59 9.32 1010 5.02 3-32 2.08 1.79 L93 1.75 1.77 2.14 217 1.72 1.61 1.62 1.93 L68 2.08 2.55 2.35 3.03 3.87 4.16 429 5.06 3.0%Damp GPk .56 .87 .70 .66 .74 L09 102 L40 1.86 1.88 1.89 238 212 214 3.02 2.63 534 721 8.30 4.72 2.95 L96 1.72 183 1.66 1.61 1.89 2.00 1.58 1.47 1.60 1.75 1.57 1.97 2.43 2.03 2.71 3.41 3.49 3.63 4.40 5.0%Damp GPk .44 .68 .57 .58 .65 .83 .81 1.04 L42 L46 L40 1.76 L84 L88 2-49 2.45 4.30 5.79 6.04 3.92 2.53 L85 1.67 L70 1.58 1.51 170 1-76 1.43 139 1.53 1.54 1.53 1.82 2.20 188 2.37 2.84 2.89 2.83 3.52 7.0%Damp GPk 37 .58 .50 .51 .59 69 .70 .89 1.16 130 113 1.46 1.63 1.68 2.11 232 3.61 4.83 4.73 3.23 2.24 1,81 1.65 1.63 1.53 L51 L62 1.61 1.37 134 1.46 142 1.49 1.72 2.03 1.87 2.18 2.51 2.50 2.53 2.97 LZRPLOT Ver. 2.1n 03-22-2012

TEST RESPONSE SPECTRA Data P*ie: Q1206002 22-12 2:36p Accel No. 11 1/6 Octave ZPA: .96 gPk REQUIRED RESPONSE SPECTRA RRS File, QI206OBE.RRS 22-12 9:17a 10.0 7.0 5.0 4.0 3.0 I i I ! A 2.0 c c e 1"r a t .9 0 7 (g's) .5 .4 .3 .2 I I _1 j ........... 711 N]I AA 1N f II I i A.[AII I J ip Z M m0 11:0 .I I .1 3 4 5 6 7 8 10 Frequency (Hertz) 20 30 40 50 60 70 80 100 LZRPLOT Ver. 2. In 03-22-2012

Report No, EGS-TR-HC589-01 Appendix II, Page No. 53 TEST RESPONSE SPECTRA Data File: Q1206002 22-12 2:36p Accel No. U 1/6 Octave ZPA:.96 gPk Required Response Spectra Fr1 Accel F5 Ace Freq Accel M 35 10.00 1.05 50.00 35 3.00 L05 20.00 35 100.00 .35 Test Response Spectra REQUIRED RESPONSE SPECTRA RRS File: Q1206OBE.RRS 2242 9-J7a Freq 1.12' L26 L41 1.58 1.78 2.00 2.24 2.51 2.82 3.16 3.55 3.98 4.47 5.01 5.62 631 7.08 7.94 8.91 10.00 U1122 1259 14.13 15.85 17.78 19.95 22.39 25.12 28.18 31.62 35.48 39.81 44.67 5012 56.23 63.10 70.79 79.43 89.B 100.00 .5%Damp GPk L08 137 1.56 126 1.69 1.63 2.32 2.63 2.87 2.67 3.62 2.88 2.48 3.31 3.42 3.38 2.52 3.33 3.23 5.03 3.26 4.49 1.71 L56 235 1.89 1.40 2.34 2.35 2.84 2.03 1.74 1.42 1.49 L59 2.47 3.44 3.47 4.45 6.04 5.62 2.0%Damp GPk .60 .82 L19 1.03 119 1.20 1.39 1.56 1.57 1.80 199 1.68 1.80 187 1.80 1.94 1.82 2M 193 2.29 2.47 2.17 124 .99 1.39 1.21 133 155 1.51 L77 1.33 121 L43 123 132 2.13 2.88 2.89 2.71 4.57 3.76 3.0%Damp 5.0%Damp GPk GPk .50 .40 .66 .53 1.01 .76 .92 .74 .98 .74 1.01 .82 1.10 .80 1.26 1.00 135 1.10 1.56 1.27 1.57 1.12 1.42 120 1.62 1.28 1.52 116 1.65 1.39 1.57 1.23 1.65 139 1.76 L44 1.63 1.32 1.86 L48 2.10 1.64 1L69 1.23 1.10 .97 .92 .87 1.23 1.04 1.08 -99 1.26 115 132 120 1.31 1i1 1.57 1.28 1.19 1.00 1.10 101 130 1.15 1.21 1.15 1.24 1-11 1.97 1.68 2.63 2.28 2.59 2.17 2.42 2.14 4.03 3.32 3.43 2.93 7.0%Damp OPk '33 .44 .66 .62 .62 .70 .72. .86 .95 108 91 1.03 1.09 1.03 1.21 1,13 117 125 116 127 137 109 ,89 .82 93 .94 1.07 1.12 107 L07 .95 .97 1.06 108 1.03 2.00 1.88 191 2.84 2.58 LZRPLOT Ver. 21n 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206003 22-12 2 :3 8p Accel No. 1 1/6 Octave ZPAk .53 gPk REQUIRED RESPONSE SPECTRA RRS *ile' Q1206OBE.RRS 22-12 9:17a 5.0 4.0 3.0 2.0 A c c e 1 r 1.0 .8 a t i .6 0 n .5 (g's) .4 .3 .2 .1 J - -. 4 -.. X ip OL 0 am o 0

  • A I

2 3 4I 1 0 7 8 0U Frequency (Hertz) 20 30 40 50 60 70 80 100 LZRPLOT Ver. 2. In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 55 TEST RESPONSE SPECTRA Data File. Q1206003 22-12 2:38p REQUIRED RESPONSE SPECTRA Accel No. 1 1/6 Octave ZPA. .53 gPk RRS File: Q1206OBE.RRS 22-12 9-17a Required Response Spectra Fre Accel Fre Accel Fr Accel _35 10.0 105 50 e 35 3.00 1.05 20.00 35 100.00 35 Test Response Spectra Freq 5%Damp 2.0%Damp 3.0%Damp 5.0%Damp 7.0%Damp GPk GPk GPk GPk GPk .56 .46 .42 .36 .32 L12 1.62 110 .95 .73 .59 1.26 1.71 L26 1.08 .83 .70 1.41 1.58 94 .83 .73 .66 1.58 1.81 1.14 .97 .77 .64 1.78 1.45 L06 .88 .72 .64 2.00 2.08 1.31 1.13 .94 .82 Z24 2,02 139 1.22 1.10 .97 2.51 1.33 116 1.07 .95 .97 2.82 3.07 1.83 1.54 1.21 1.05 3.16 4.23 2.26 1.78 136 112 3.55 2.73 1.53 1.39 126 1.12 3.98 2.78 1.91 L68 137 1.15. 4.47 2.57 Z21 1.88 1.44 119 5.01 2.91 1.91 1.73 141 1,21 5.62 3.79 1.84 1.55 134 L22 6.31 3.40 2.34 2.08 1.71 1.46 7.08 339 21.0 1.82 1.48 1.28 7.94 3.86 2.83 2.39 185 1,52 8,91 3.59 1.90 1.74 1.41 121 10.00 2.85 2.04 1.73 1.33 1.1 11.22 Z49 131 1.21 1.12 .99 12.59 3.79 1.99 1.58 1.15 .96 14.13 1.76 112 1.00 .90 .83 15.85 152 .97 .86 .81 .76 17.78 2.03 1.20 L08 .91 .80 19.95 1,80 L07 .92 .78 .74 22.39 1.41 .87 .80 .72 .71 25.12 110 S5 .80 .77 .74 2818 .97 .82 .82 .79 .76 3L62 .98 .80 .76 .71 .68 35.48 .79 .69 .67 .65 .64 39.81 .72 .63 .63 .63 .62 44.67 .69 .64 .63 .62 .61 50.12 .69 .60 .59 ,59 .58 56.23 .68 .63 .61 .59 .58 63.10 .62 .61 .61 .61 .60 70.79 .73 .62 .61 .59 .58 79.43 .63 -56 .56 .56 .56 89.1B .63 .56 .55 .54 .54 100.00 .72 .60 .58 -56 .55 LZRPLOT Ver. 2.1n 03-22-2012

TEST RESPONSE SPECTRA Data Pile: Q1206003 22-12 2:38p Accel No. 2 1/6 Octave ZPA: .65 gPk REQUIRED RESPONSE SPECTRA RRS File: QI206OBE.RRS 22-12 9:17a 10.0 7.0 5.0 4.0 3.0 2.0 .9 .7 I I I A C C eI e r a ti 0 U1 I 4 7..~.[............... .li ."iI ip X M o 0) (gs) .5 .4 .3 .2 .1 I Z .5 4 a I Is 1U 20 30) 40 30 60 70 90 100 Frequency (Hertz) LZRPLOT Ve*

2. In 03-22-2012

Report No. EGS-TR-HC589.01 Appendix I1, Page No. 57 TEST RESPONSE SPECTRA Data Fide; Q1206003 22-12 2138p REQUIRED RESPONSE SPECTRA Accel No. 2 1/6 Octave ZPA:.65 gPk RRS File: Q1206OBE.RRS 22-12 9-17a Required Response Spectra Fr Accel Fr~e Accel Freq Accel r 35 A0.0 1.05 50.00 .35 3.00 L05 20.00 .35 100.00 .35 Test Response Spectra Freq .5%Damp 2.0%Damp 3.0%Damp 5.0%Damp 7.0%Damp (hz) GPk GPk GPk GPk GPk 1O0 .86 .65 .56 .45 -37 112 189 .96 .80 .63 .53 126 1.08 .78 .66 .52 .46 1.41 1.20 .72 £2 .51 .45 1.58 .87 .71 .66 .58 .53 178 1.77 121 .99 .76 .63 2.00 L56 1.10 .94 .76 .64 2.24 3.01 L61 1.26 .95 .80 2.51 2.21 L96 1.70 1.32 1.06 2.82 2.77 181 1.52 L22 L08 3.16 3.62 L94 1.54 1.12 .90 3.55 4.84 2.43 1.85 1.37 1.12 3.98 3.17 L78 1.52 1.30 1.14 4.47 2.88 1.74 1.50 132 1.15 5.01 2.75 226 1.94 1.57 1.34 5.62 2.42 L46 1.32 1.23 114 631 4.14 2.38 194 1.42 1.15 7.08 4.53 2.54 2.05 1.52 1.24 7.94 3.26 2.21 1.92 1.52 L26 8.91 330 1.93 1.71 L41 1.21 10.00 3.62 1.96 1.55 124 1.10 11.22 2.48 1.47 128 L06 .93 12.59 .85 1.38 1,29 1.18 .l1 14.13 238 1.57 1m50 1.37 1.28 1585 3.20 1.78 L59 1.44 1.33 17.78 5.41 3.06 2.55 2.01 1.69 19.95 531 2.98 2.53 2.03 L71 22.39 2.56 1.84 1.63 L40 1.26 25.12 1.37 1.07 1.04 L04 1.01 28.18 L35 126 1.20 L1l 1.05 3L62 120 1.03 1.00 .97 .95 35.48 .96 .80 .78 .79 .80 39.81 .92 .83 .82 .80 .78 44.67 .77 A7 .65 .66 .67 50.12 .78 b7 .66 .67 .67 56.23 .82 .71 .71 .71 .71 63.10 .73 .73 .73 .73 .72 70.79 .80 .74 .72 .71 .71 79.43 .71 .69 .68 .68 .68 89.13 .73 .69 .68 .68 .68 100.00 .68 .70 .70 .70 .69 LZRPLOT Ver. 2.1n 03-22-2012

TEST RESPONSE SPECTRA. Data Pile: Q1206003 22-12 2:38p Accel No. 3 116 Octave ZPA: .58 gPk REQUIRED RESPONSE SPECTRA RRS File: QI206OBE.RRS 22-12 9:17a 5.0 4.0 3.0 2.0 A Cc e a t 0 n. (gWs) 1.0 .8 .6 .5 .4 I_ I~. ~l..... I AIA cii X-A, .L. Ij CD m0 .3 .1 4' Frequency (Hertz)

  • v LZRPLOT Ver. 2.1n 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 59 TEST RESPONSE SPECTRA Data File: 01206003 22-12 2 3 8p AccelNo. 3 1/6Octave ZPA:.58 gPk Required Response Spectra Fre Accel Fr* Accel Freq Accel .35 10.0 1.05 50.00 .35 3.00 1.05 20.00 .35 100.00 .35 REQUIRED RESPONSE SPECTRA RRS File: Q12060BE.RRS 22-12 9:17a Test Response Spectra Freq .5%Damp (*.Z) GPk L04 1.12 1L52 1.26 154 141 1.25 1.58 1.64 1.78 L60 2.00 2.30 2.24 2.64 2.51 2.83 2.82 2.71 3.16 3.54 3.55 2.81 3.98 3.03 4.47 3.18 5.01 3.29 5.62 3.28 6.31 2.38 7.08 3.01 7.94 327 8.91 4.78 10.00 2.89 1122 4.05 12.59 L41 1413 1.30 15.85 1.83 17.78 1.36 19.95 127 2239 1.86 25.12 2.21 2&18 1.96 31.62 1.32 35.48 123 39.81 .89 44.67 .95 50.12 .96 56.23 .99 63.10 .82 70.79 .67 79.43 .64 89.13 .75 100.00 .81 Z0%Damp 3.0%Damp GPk GPk .58 .48 .95 .78 U7 .99 101 .90 1.16 .95 117 .99 136 108 155 126 157 136 1.79 155 196 1.56 L71 1.45 1.85 165 1.85 149 181 L66 191 155 173 155 194 1.75 196 1.59 2.13 1.73 232 L97 2.06 L63 L12 1.05 .89 .85 L14 1.02 1.00 .96 1.05 L01 1.30 1.12 1.29 114 1.40 1.19 .98 .89 .97 .96 .89 .90 .95 .93 .92 .90 .90 .87 .76 .74 .64 .64 .63 .63 .65 .65 .63 .63 5.0%Damp 7.0%Damp GPk GPk 38 32 .60 .50 .75 .64 .73 .61 .72 .60 .81 .70 .79 ..70 .99 £5 LOS .92 1.26 1.07 L12 .90 L16 1.00 1.29 L09 L15 L02 L41 1.23 1.28 1.17 130 1.10 1.45 1.26 137 1.25 138 123 154 1.27 L21 1.11 .97 .91 .81 .78 .88 .80 .89 .84 -95 .89 .98 .92 .94 .88 .94 .89 .87 .85 .92 .89 £88 .86 £89 £6 £6 .83 .83 .80 .72 .70 .64 .63 .63 .62 .63 .63 .62 .62 LZRPLOT Ver. 2ln 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206003 22-12 2 :38 p Accel No. 4 1/6 Octave ZPA: 1.17 gPk REQUIRED RESPONSE SPECTRA RRS File: Q12060BE.RRS 22-12 9:17a 25.0

2. ______

1~i f F~22H~ I ~ t+i* ~-- 4-1 -,-4----i--. + - -4.. PH 1 -......A i-+ 10.0 7.0 5.0 1 I11 'A ff. SI iI* I I I iI -~ ~..... A c c e1 r a ti 0 n i x it, LJ.'

,".:N

\\ I. f I i 3.0 2.0 1.0 (gs) .7 .5 .3 .2 .1 1-I I_ rT:tT I

1.

I j r -L +/- H 1i+/- t-+-.:=+ 3Z MT 0 C) I 2 3 4 5 6 7 8 10 Frequency (Hertz) 20 30 40 50 60 70 80 1.00 LZRPLOT Ver. 2. In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 61 TEST RESPONSE SPECTRA Data File: Q1206003 22-12 2:38p Accel No. 4 1/6 Octave ZPA: L17 gPk Required Response Spectra Fjr Accel Fr Accel Freq Accel .35 10.00 1o0 SOLO 35 3.00 1.05 20.00 35 100.00 35 REQUIRED RESPONSE SPECTRA RRS File: 01206OBE.RRS 22-12 9:17a Test Response Spectra Freq .5%Damp Qiz) GPk 1-00 .56 L12 157 1.26 1.76 1.41 1.71 1.58 1.94 1.78 1.56 2.00 2.14 2.24 .219 2.51 1.55 2.82 324 3.16 4.66 3.55 311 3.98 3.34 4.47 2.69 5.01 3.52 5.2 4.78 6.31 4.13 7.08 5.11 7.94 5.63 8.91 6.40 10.00 5.47 11.22 6.35 12.59 14.09 14.13 8.15 15.85 6.94 17.78 6.23 19.95 2.80 2239 2.07 25.12 2.07 28.18 2.05 31.62 L93 35.48 3.09 39.81 157 44.67 L77 5012 2.83 56.23 221 6310 2.01 70.79 2.66 79.43 3.49 89.13 330 100.00 L79 2.0%Damp 3.0%Damp GPk GPk .47 .43 1-12 .97 1.30 112 1.02 .89 120 1.02 107 .90 131 1.14 1.47 1.28 1.26 L14 L93 1.62 2.48 1.95 1.79 1.52 2.07 1.81 2.45 2.11 2.20 2.04 2.24 1.98 2.93 2.58 3.00 2.57 4.22 3.57 336 Z91 3.59 3.19 3.63 3.54 7.06 5.55 5.70 4.98 4.18 4.00 3.73 3.11 1.96 1.82 L58 1.47 1.70 1.57 1.53 139 1.49 1.47 L93 1.80 2.00 1.84 1.42 L44 1.81 1.50 1L68 1.61 1.51 1.43 1.98 1.81 2.35 2.02 Z46 213 160 1.54 5.0%Damp 7.0%Damp GPk GPk -37 -33 .74 .60 .87 .74 .78 .70 .80 .66 .76 .67 .96 .84 1.15 1.01 .99 .90 129 1.12 1.49 1.23 138 L24 1.46 123 1.65 1.39 1.75 1-53 1.70 L48 2.16 1.85 2.08 L92 2.77 2.28 2.36 2.00 2.71 2.34 324 2.88 3.90 3.06 3.97 332 3.59 3.22 2.48 2.24 1.64 1.61 137 1.36 1.43 135 136 1.34 1.45 1.42 1.65 1.54 1.59 1.43 1.37 129 134 1.27 1.50 L40 1.34 130 154 1.42 1.70 1.59 L83 1.66 1.44 1.43 LZRPLOT Ver. 2.1n 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206003 22-12 2:38p Accel No. 5 1/6 Octave ZPA: 1.70 gPk REQUIRED RESPONSE SPECTRA RRS File: Q1206OBE.RRS 22-12 9:17a 50.0 30.0 20.0 10.0 7.0 A c e1 r a ti 0 I 5.0 3.0 2.0 - -p-...... .1-..... _~,__ 12 A* c 9 t nAt C A 1A o mp CL) -0 Wgs) 1.0 .7 .5 .3 .2 .1 In Frequency (Hertz) LZRPLOT Ver. 2. In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix I1, Page No. 63 TEST RESPONSE SPECTRA Data File: Q1206003 22-12 2:38p Accel No. 5 1/6 Octave ZPA. L70 gPk Required Response Spectra REQUIRED RESPONSE SPECTRA RRS File: Q1206OBER.RS 22-12 917a Fr Accel 30 1.35 3.00 1.05 F2OO 20.00 Accel 1.05 35 Freq 50.00 100.00 Accel 35 35 Test Response Spectra Freq 132 1.26 L41 158 1.78 2.O0 2.24 2.51 2.82 316 3.55 398 4.47 501 5.62 631 7.08 7.94 &91 10.00 11.22 12.59 14.3 15.85 17.78 19.95 22.39 25.12 28.18 31.62 35.48 39.81 44.67 50.12 5623 63.10 70.79 79.43 89.13 100.00 .5%Damp GPk .89 1.96 11 1.22 .99 1.91 L69 3.35 2.57 3.56 4.71 6.29 4.58 4.66 5.23 6.07 14.76 26.39 26.83 12.95 910 5.02 3.44 3.29 3.52 4.21 4.12 2.60 4.21 535 3.20 4.22 2.91 2.50 2.35 2.81 2.74 2.30 3.37 2.83 2.38 2.0%Damp GPk .68 L01 .79 .75 .75 135 1.23 1.83 2.23 2.40 2.52 3.18 2.65 2.68 4.08 3.69 8.76 13.03 1484 7.57 5.17 3.43 2.78 2.67 2.84 3.21 2.85 2.61 2.84 337 2.54 283 2.25 2.08 2.19 2.43 2.37 191 2.83 2.55 2.02 3.0%Damp GPk .58 .85 .71 .65 .70 1.13 106 L44 L88 2.05 2.04 2.54 237 2.47 3.48 3.60 7.08 10.17 12-28 7.01 4.52 3.18 2.67 2.59 2.70 3.01 2.55 2.65 2.69 2.84 2.27 2.57 2.15 2.09 2.16 2-31 2.27 1.90 2.62 2.46 1.99 5.0%Damp GPk .45 .67 -56 .56 62 £8 84 108 1.43 159 1.52 1.91 2.06 2.17 2.89 335 5.75 831 8.97 5.79 3.86 2.95 2.59 2.51 2.51 2.77 2.53 2.61 2.51 2.42 2.14 2.28 2.06 2.07 2.11 2.18 2.15 1.88 233 2.30 1.96 7.0%Damp GPk .38 .57 .49 .50 .57 -73 .75 .96 L15 1.38 L24 1.60 1.84 1.95 2.63 315 485 691 7.03 4.75 3.47 2.85 2.56 2.47 2.40 2.63 2.52 2.52 2.40 230 2.08 2.10 1.98 2.04 2.07 2.11 2.07 L86 2.18 2.19 1-93 LZRPLOT Ver. Z2n 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206003 22-12 2:38p Accel No. 6 1/6 Octave ZPA: .76 gPk REQUIRED RESPONSE SPECTRA RRS File: Q12060BE.RRS 22-12 9:17a 10.0 7.0 5.0 4.0 3.0 .i I A c c e r ati 0 n (g's) 2.0 .9 .7 .5 .4 .3 .2 .1 M 7-I.A.............. .ýL, A T 000 010 00 kZ 00 -+4 Lol" A. ip jýiZ ,7A. 0 X. M C6 Z00 2 4 6 7 8 10 Frequency (Hertz) 20 30 40 so 60 70 80 100 LZRPLOT Ver. 2.In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 65 TEST RESPONSE SPECTRA Data File: Q1206003 22-12 2:38p REQUIRED RESPONSE SPECTRA Accel No. 6 1/6 Octave ZPA:.76 gPk RRS File: Q1206OBE.RRS 22-12 9.l7a Required Response Spectra Freq Accel Fr~e Accel Freq Accel L00 .35 10.00 1.05 50.00 35 3.00 1.05 20.00 .35 100.00 .35 Test Response Spectra Freq .5%Damp 2.0%Damp 3,0%Damp 5.0%Damp 7.0%Damp (hz GPk GPk GPk GPk GPk 1% 110 .63 52 .41 .35 1.12 165 104 .85 .66 .55 1.26 1.67 126 .07 .80 .68 1.41 135 108 .96 .77 .64 1.58 1.74 1.25 1.04 .79 .66 L78 1.73 1.26 L07 .88 .75 2.00 2.43 L45 1.15 .84 .75 2.24 2.87 1.69 1.37 1.09 .94 2.51 2.97 1.72 L48 112 .98 2.82 2.92 1.93 1.66 135 1.14 3.16 3.78 2.12 1.69 121 .96 3.55 3.10 1.91 L59 1.25 1.07 3.98 320 1.97 175 1.37 116 4.47 3.34 1.96 1.58 1.24 110 5.01 3.47 199 1.82 1.54 L35 5.62 3.50 2.03 1.65 1-40 128 631 2.50 1.84 1.67 1.39 1.19 7.08 3.25 2.02 1,84 1.55 1.35 7.94 3.57 2.13 1.79 1.55 L42 8.91 5.37 2.38 194 154 1.39 10.00 3.36 7.66 2.25 1.76 1.46 11.22 4.81 2.34 1.82 137 1.21 12.59 L78 1.25 117 L08 .98 14.13 1.56 1.06 1.05 L00 .95 15S5 2.79 163 1.46 124 L09 17.78 2.06 122 116 1.10 1.05 19.95 1.70 1.6 .15 1.10 L06 2239 2.16 L63 1A. 1.11 1.05 25.12 160 1.16 115 108 1.01 28.18 1V77 1.32 1.4 .93 .86 3L62 1.58 L06 .97 .90 .85 35.48 1.24 .97 .94 .88 .84 39.81 .96 .91 .90 86 .83 44.67 1.57 L24 114 .98 86 50.12 1.87 L48 1.29 1.05 .92 5623 1.04 .93 .91 .89 .88 6310 .99 .92 .90 .88 ,87 70.79 1.52 L41 127 105 .91 79.43 2.23 160 L40 110 .92 89.13 L44 121 1.12 .99 .92 100.00 1.91 1.41 1.25 1.05 .94 LZRPLOT Ver. 2.ln 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206003 22-12 2 :38 p Accel No. 7 1/6 Octave ZPA: 1.35 gPk REQUIRED RESPONSE SPECTRA RRS File: Q1206OBE.RRS 22-12 9:17a 25.0 10.0 7.0 5.0 3.0 2.0 1.0 A C C e I r at 0 n1 ..z .. z LL~iL L -~I 1*. lz X M = G) Z X1 M co (g9s) .7 .5 .3 .2 .1

  • A I

2 3 4 3 0 7 8 IU Prequency (Hert) 20l 30 40 U 5 60 70 80 10UO LZRPLOT Ver. 2.In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix I1, Page No. 67 TEST RESPONSE SPECTRA Data File: Q1206003 22-12 2.38p Accel No. 7 1/6 Octave ZPA: 1.35 gPk Required Response Spectra REQUIRED RESPONSE SPECTRA RRS File: Q1206OBERRS 22-12 9-17a FrI Accel 10 35 3.00 1.05 Freq 10.00 20.00 Test Response Spectra Freq 1.12 L26 1.41 1.58 1.78 2.00 224 2.51 2.82 3.16 3.55 3.98 4.47 5.01 5.62 631 7.08 7.94 .91 10.00 11.22 1259 14.13 15.85 17.78 19.95 22-39 25.12 28.18 3162 35.48 39.81 44.67 50.12 5623 63.10 70.79 79.43 89.13 100.00 .5%Damp OPk .53 1.65 1.76 1.64 1.88 1.52 2.16 2.15 1.48 3.28 4.55 3.07 3.14 2.73 3.50 4.82 4.30 4.51 6.14 6.28 5.68 6.65 14.52 &43 7.48 639 5.66 4.06 3.39 4.41 1039 1018 4.23 3.25 3.02 2181 2.19 2.07 1.97 3.17 3.63 Accel 1.05 35 2.0%Damp GPk .45 110 128 .97 1.19 1.07 1.36 146 1.26 1.96 7-45 1.75 2.09 2.43 2.18 2.29 3.07 2.81 4.32 328 3.66 3.79 733 5.79 4.48 3.94 3.36 3.23 2.51 3.10 5.69 5.80 2.53 2.32 2.37 1.97 L91 1.80 1.69 2.09 2.42 lOFre Acel -35 .35 3.0%Damp GPk A1 .95 L09 .85 1.02 .89 118 1.26 1.15 1.64 L94 1.52 1,83 2.08 2.03 2.01 2.68 2.45 3.63 2.89 3.24 3.58 5.76 5.06 4.19 339 2.91 2.83 2.34 2.83 4.91 4.76 2.38 2.14 2.23 1.91 1.83 1.74 L64 1.81 2.06 5.0%Damp GPk 36 .72 .86 .75 .79 .74 .99 115 1.00 1.30 L46 1.37 1.49 1.61 1.74 1.72 2.21 2.11 2.80 234 2.75 3.28 4.07 4.05 3.65 2.83 2.42 231 2.16 2.35 3.78 3.57 230 1.95 2.08 1.85 1.76 1.67 1.59 1.59 1.77 7.0%Damp GPk 32 .59 .73 .68 .65 .65 .85 L02 .91 1.1 121 1.22 1.26 1.34 1,52 1.49 1.90 1.98 2.31 1.97 2.36 2-92 3.21 3.47 3.20 2.51 2.10 L98 2.02 2.14 3.02 3.07 2.25 191 L99 1.82 L73 1.63 1.57 1.59 1.65 LZRPLOT Ver. 2.1n 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206003 22-12 2 :3 8p Accel No. 8 1/6 Octave ZPA: 1.44 gPk REQUIRED RESPONSE SPECTRA RRS ile: QI206OBE.RRS 22-12 9:17a 25.0 10.0 7.0 5.0 A c c e1 r a t i 0 n 3.0 2.0 1.0 I~ I Vi f- -7t ý- t-1-{ .21 ~................... "i K 2 7 +/- 1IZII i i II+ A C' 0 1 A 01% Af% C A I AM 01U 1S CfD Y~ (g's) .7 .5 .3 .2 .1 IA ,J I O JlK/ .*U V

  • J V

k" Frequency (Hertz) LZRPLOT Ver. 2. In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 69 TEST RESPONSE SPECTRA Data File: Q1206003 22-12 2:38p Accel No. 8 1/6 Octave ZPA. 1.44 gPk REQUIRED RESPONSE SPECTRA RRS File: Q1206OBE.RRS 22-12 917a Required Response Spectra Fr Accel F .35 10.00 3.00 L05 20.00 Test Response Spectra Accel 105 .35 100.00 Accel .35 .35 Freq Lob 1.12 1.26 1.41 L58 1.78 2.00 2.24 2.51 2.82 3.16 3.55 3.98 4.47 5.01 5.62 6.31 7.08 7.94 8.91 10.00 11L22 12.59 14.13 15A5 17.78 19.95 22.39 2512 28.18 31.62 35.48 39.81 44.67 50.12 56.23 63.10 70.79 79.43 89.3 100.00 .5%Damp GPk 89 193 1.08 1.17 92 .89 1.68 331 2.55 3.45 4.54 6.09 4.42 4.44 5.01 5.80 13.70 24.09 24.28 1133 8.06 429 2.90 2.63 2.45 356 2.66 2.56 2.56 2.02 2.04 227 L60 L91 L91 2.78 2.64 2178 2.64 2.79 2.24 2.0%Damp GPk .67 1.04 .78 .73 .78 1.31 120 178 2.19 2.32 2.44 3.08 2.54 2-55 3.91 3.43 8.10 1191 13.30 6.73 4.57 2.96 234 213 2.06 2.43 2.03 1.96 2.03 174 L.71 1.80 1.52 1.50 1.69 2.07 2.13 2.23 2.03 2.11 1.82 3.0%Damp GPk .87 .69 .67 .72 108 1.02 L40 1.86 198 1.99 2.46 2.27 2.39 3.35 3.34 6.54 9.21 1I01 6.23 4.05 2,69 227 2.09 1.95 2.26 1.99 190 2.00 1.64 166 L70 1.50 1.45 1.63 1.88 2.07 2.16 1.99 1.92 1.69 5.0%Damp GPk .45 .68 .57 .58 .63 S3 .82 1.05 1.41 1.54 1.49 1.84 1.97 2.10 2.75 3.07 5.30 7.48 8.04 5.14 3.47 2.56 2.23 2.06 1.86 2.09 1.89 1.89 1.91 1.59 1.58 159 1.46 L46 1.59 1.66 L95 2-07 1.91 1.74 1.62 7.0%Damp GPk -38 .57 .49 .52 .57 .69 .72 .95 113 134 1.21 1.54 1.75 1.84 2.43 2.89 4.46 6.23 630 422 3.15 2.52 2.21 2.04 1.85 199 1,86 185 1.84 1.54 1.53 1.53 1.46 1.46 156 1.58 185 197 1.85 1.71 1.59 LZRPLOT Ver. 2.1n 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206003 22-12 2 :38p Accel No. 9 1/6 Octave ZPA: 1.04 gPk REQUIRED RESPONSE SPECTRA RRS Pile: Q1206OBE.RRS 22-12 9:17a 25.0 1.': :1izz +/-H 7-I T.117 ~HI~

  • JI

!L I K I ] 1--L A C C e r a t i 0 n 10.0 7.0 5.0 3.0 2.0 1.0

"""~~~.....

I

~~

~ I' T fr. S-4 (g's) .7 .5 .3 .2 .I I 2 3 4 5 6 7 8 10 Prequency (H.rtz) 20 30 40 50 60 70 80 100 LZRPLOT Ver. 2. In 03-22-2012

Report No, EGS-TR.HC589-O1 Appendix II, Page No. 71 TEST RESPONSE SPECTRA Data File: 01206003 22-12 2:3 8p REQUIRED RESPONSE SPECTRA Accel No. 9 1/ 6 Octave ZPA: 1.04 gPk RRS File: Q1206OBE.RRS 22-12 917a Required Response Spectra Freq Accel Frcq Accel Freq Accel L0 .35 1000 1.05 50.00 .35 3.600 -05 20.00 35 100.00 35 Test Response Spectra Freq .5%Damp 2.0%Damp 3.0%Damp 5.0%Damp 7.0%Damp .*z0 GPk GPk GPk GPk GPk .52 .44 .40 .36 32 1.12 1.60 1.10 .95 .73 .59 126 1.70 1.26 1.07 .82 .69 1.41 1.56 .93 .83 .73 .66 158 1_80 U14 .97 .76 .63 !78 1.47 1.07 .89 .71 .63 2.00 2.05 1.31 114 .96 .83 2.24 2.05 139 1.27 1-14 LOO 2.51 1.41 119 1.09 .96 S9 2.82 3.07 1.87 1.58 125 L06 3.16 4.44 2.35 1.86 1.42 117 3.55 2.90 1.63 1.47 1.30 116 3.98 2.96 1.99 1.75 1.42 1.20 4.47 2-68 235 zo1 1.54 1.28 5.01 3.17 2.09 1.96 1.67 L46 5.62 4-33 2.04 1.83 1.58 1.41 6.31 3.89 2.69 242 2.02 1.73 7.08 4.51 2.66 Z27 1.85 1.74 7.94 5.03 3.73 3.17 Z47 2.03 8.91 5.45 2.83 2.58 2.09 1.77 10.00 4.79 3.17 2.67 2.25 1.93 1112 5.39 2.92 2.82 2.59 231 12.59 1L05 5.60 4.41 3.10 2%45 1413 6.29 4.38 3.84 3.08 2.58 15.85 4.70 3.14 2.98 2.67 239 17.78 3.34 2.33 2.14 1.92 1.77 19.95 1.56 1.28 130 1.30 129 22.39 1.61 1.29 1.19 1.15 1.14 2512 2.17 1.33 1.26 119 1.13 28.18 1.97 1.73 1.64 1.50 1.41 3162 2-81 1.92 1.75 1.55 1.45 35.48 4.91, 3.15 2.63 2.00 1.75 39.81 2.87 2.00 1.80 1.65 1.51 44.67 2.63 1.77 167 L61 1.57 50.12 3.76 2.75 2.44 2.02 1.73 56.23 2.46 1.74 1.64 1.50 1.41 63.10 2.59 1.86 1.67 1.53 1.44 70.79 2.94 1.67 157 1.53 1.49 79.43 4.34 2.51 2.20 1.79 1.57 89.13 5.57 2.74 2.15 1.73 1.50 100.00 2.67 1.90 1.70 1.42 1.30 LZRPLOT Ver. 2.1n 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206003 22-12 2 :3 8p Accel No. 10 1/6 Octave ZPA: 1.66 gPk REQUIRED RESPONSE SPECTRA RRS File: Q12060BE.RRS 22-12 9:17a 25.0 --I-. ~.-,-------.-,..-.--.t -t-A A c C C r at 1.0 n 10.0 7.0 5.0 3.0 2.0 1.0 I~ Mt I~ 4 1 'Of 4J11i1...II .A....of

o CL.0~

(g1s) .7 : .5 .3 .2 .1 2 3 4 5 6 7 8 10 Frequency (Hertz) 20 30 40 50 60 70 80 100 LZRPLOT Vet. 2.1n 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 73 TEST RESPONSE SPECTRA Data File: Q1206003 22-12 2:38p REQUIRED RESPONSE SPECTRA Accel No. 10 1/6 Octave ZPk 1.66 gPk RRS File: Q1206OBERRS 22-12 9-17a Required Response Spectra Freq Accel F Accel Fre Accel 1.00 35 10N L.05 35 3.00 1.05 20.00 35 100.00 35 Test Response Spectra Freq -5%Damp 2.0%Damp 3.0%Damp 5.0%Damp 7.0%Damp (hz0 GPk GPk GPk GPk GPk .85 .65 .56 .44 37 L12 1.94 103 .86 .68 .57 126 1.09 .79 .69 .56 .49 1.41 L20 .73 .65 .57 .50 1.58 .90 .79 .73 .64 .58 1.78 1.91 1.32 1.09 .84 .70 200 1.71 121 L03 .81 .70 2.24 3.31 L77 139 1.04 .90 2.51 2.50 218 186 L42 1.15 2.82 3.30 221 1.88 147 L31 3.16 4.36 2.33 1.89 L41 114 3.55 6.00 2.99 2.37 1.77 1.47 3.98 4.18 2.37 2114 185 L64 4.47 415 2.35 2.18 191 L70 5.01 4.55 3.56 3.05 2.51 2.13 5.62 5.05 3.04 2.75 2.52 2.36 6.31 11.50 676 5.44 4.39 3.69 7.08 19.37 9.66 7.43 5.87 4.90 7.94 1&76 10.09 837 6.14 4.82 8.91 &46 5.08 4.71 3.90 322 10.00 5.76 333 2.95 2.52 225 1122 2.97 2.13 2.01 L94 1.90 1259 2.32 1.85 1.79 174 L72 14.13 2.27 1.95 1.84 L73 L67 15.85 2.44 182 1.73 L65 L60 17.78 2.85 1.68 1.56 L61 L60 19.95 3.26 2.52 2.23 180 1.67 2239 4.02 2.25 2.07 1.83 1.67 2512 2.53 189 L71 1.50 1.39 2818 2.41 L60 1.50 1.40 1.35 31.62 2.11 1.66 L65 1.59 151 35.48 2.46 1.86 L70 L56 1.48 39.81 2.24 1.84 1.63 1.54 151 44.67 2.48 1.98 1.92 181 1.71 50.12 2.87 2.52 Z42 2.20 2.02 56.23 2.76 207 -89 1.88 1.88 6310 4.11 2.94 2.62 2.30 2.12 70.79 5.60 3.37 2.90 2-54 2.30 79.43 6.28 4.02 3.46 300 2.81 8913 1234 6.74 5.47 4.40 3.80 100.00 8.36 5.19 4.36 3.60 3.23 LZRPLOT Ver. 2-n 03-22-2012

TEST RESPONSE SPECTRA Data Pie: Q1206003 22-12 2:38p AccelNo. 11 116Octave ZPA: 1.10gPk REQUIRED RESPONSE SPECTRA RRS File: Q12060BE.RRS 22-12 9:17a A c C e 1 e r at 0 n (g's) 10.0 7.0 5.0 4.0 3.0 2.0 .9 .7 .5 .4 .3 I .., I I ...1 - -T IA I i.~- NJ-H ~~ ~~ N .... *-"""":"-** ~ ~ ~~~~....I............. ,i.. 4... 21 3 46 8005 1020 30 40 50 60 70 80 1G m .=0 C:q .1 I H)0 Frequency (Hertz) LZRPLOT Ver. 2.In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 75 TEST RESPONSE SPECTRA Data File: Q1206003 22-12 2:38p Accel No. 11 1/6 Octave ZPA: 110 gPk REQUIRED RESPONSE SPECTRA RRS File: QM206OBF.RRS 22.12 917a Required Response Spectra Fr " Accel Freq L .35 10.00 3.00 1.05 20.00 Test Response Spectra Accel L05 .35 Fr~o Accel .35 .35 Freq 112 126 £41 1.58 1.78 ZO0O 2.24 2.51 2.82 3.16 3-55 3.98 4.47 5.01 5.62 631 7.08 7.94 8.91 10.00 1122 12.59 14.13 15.85 17.78 1995 22.39 25.12 28.18 31.62 35.48 39.81 44.67 50.12 56.23 6310 70.79 79.43 89.*3 100.00 .5%Damp GPk LOS 1.59 1.55 125 1.69 L63 2.30 2.59 2.85 2.71 3.65 2.92 299 3.25 3.38 3.38 2.56 3.35 3.28 5.11 3.31 4.61 £78 L42 2.38 1.82 1.47 2.32 2.69 2.73 L93 L48 1.53 £54 L73 2.69 3.14 2.69 4.54 7.28 4.79 2.0%Damp GPk .59 .98 £18 L02 L19 L19 1.38 1.54 1.56 £83 2.01 £L69 1.81 £87 180 1-94 1.82 2.03 196 2.35 2.50 2-19 £19 .98 L44 117 126 161 1.68 L70 127 £05 1.54 L47 148 2.32 256 218 2.97 5.35 3.22 3.0%Damp GPk .49 .79 £00 .91 .99 1.01 1.10 £26 134 1.58 L60 1.42 £63 L52 1.65 £56 1.67 £78 168 £93 2.11 £70 L07 .97 129 ill 1.21 138 £48 L45 .14 1.04 £42 136 139 2.13 2.33 2.14 2.57 4.66 2.84 5.0%Damp GPk 39 .60 .76 .74 .75 .82 £80 .99 1.09 1.28 1.14 1.21 129 115 L40 125 L40 1.46 L34 153 £64 1.25 .94 .92 1.10 L04 L13 1.19 £22 1.21 .98 LO0 L22 L23 L24 1.80 1.99 2.01 2.42 3.72 2.46 7.0%Damp GPk .33 .50 .66 .61 .62 .70 .72 85 .95 108 .92 £03 1.09 £03 121 L15 L17 1.26 L17 132 L36 1.12 .87 .8 .98 .99 1.06 1.11 £10 L09 .96 .97 £06 1.13 1.13 154 1.73 1.89 22.8 308 223 LZRPLOT Ver. 2.1n 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206004 22-12 2 :4 1p Accel No. 1 1/6 Octave ZPA: .53 gPk REQUIRED RESPONSE SPECTRA RRS FlMe: Q1206OBE.RRS 22-12 9:17a 5.0 4.0 3.0 2.0 A c c e r a ti 0C 1.0 .8 .6 .5

  • *~

~ .. I I....... l *.... r 7-I......... It L..l1 L I l .I l N I-, NN V,.., i T i *.*.1, _i.V-i..i 0: I* J"*,*....i

  • ,*.i

,.o,÷. . I..... F -,1 1" 1~~~.. 2,.

i.

4.i.. 5....1 0 0 4 5 0709 X M CD Z~C (g1s) .4 .3 .2 .1 I0 Frequency (Hertz) LZRPLOT Ver. 2. In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 77 TEST RESPONSE SPECTRA Data File: Q1206004 22-12 2141p REQUIRED RESPONSE SPECTRA Accel No. 1 1/6 Octave ZPA .53 gPk RRS File: Q1206OBE.RRS 22-12 9:-17a Required Response Spectra Freq Accel Freq Accel Freq Accel L00 35 10.00 1.05 50.00 .35 3.00 1.05 20.00 .35 100.00 .35 Test Response Spectra Freq .5%Damp 2.0%Damp 3.0%Damp 5.0%Damp 7.0%Damp Z GPk GPk GPk GPk GPk .56 .46 .42 .37 .33 1.12 1.63 1.10 .95 373 .59 1.26 1.70 1.27 1.08 .83 .70 1.41 1.56 .93 .83 .73 .66 1.58 L84 1.14 .98 .77 .64 1.78 L46 L06 .89 .72 .64 2.00 2.04 1.30 L13 .94 .83 2.24 2.01 1.39 124 1.11 .98 2.51 1.33 L17 1.07 .95 .87 2.82 3.04 L82 1.53 120 1.05 3.16 3.85 2.17 L79 1.37 1-12 3.55 2.70 1L54 1.35 1.23 10 3.98 2.79 1.90 1.68 1.36 115 4.47 2.58 2.21 1.88 L44 1.19 5.01 2.94 1.94 1.74 L41 121 5.62 3.85 186 1.55 1.34 120 631 3.48 2.40 2.13 1.76 1.51 7.08 335 2-10 184 L53 1.32 7.94 3.75 2.80 2.38 1.85 1.52 8.91 3.70 200 1.81 1.46 1.23 10.00 2-68 1.92 1.62 1.27 L12 11.22 2.23 L31 127 1.16 1.03 12.59 3.69 1.82 L48 1.10 .98 14.13 1.67 1.12 1.03 .89 .80 15.85 1.49 .97 .89 .83 .79 17.78 2-31 126 L07 .91 .81 19.95 1.83 1.01 .89 .72 .67 22.39 127 .85 .77 .69 .64 25.12 L13 .88 .80 .72 .68 2818 .92 .77 .76 .72 .68 31.62 .98 .81 .76 .70 .67 35.48 .78 .69 .67 .64 .63 39.81 .65 .61 .60 .60 .59 44.67 .63 .62 .61 .60 .58 50.12 .63 .58 .58 .57 .56 56.23 .71 .60 .59 .57 .56 6310 .67 .58 .57 .56 .55 70.79 .62 .56 .55 .55 .55 79.43 .60 .57 .57 .57 .56 89.13 .61 .57 .56 .54 -53 100.00 .61 .53 .53 .52 .52 LZRPLOT Ver. 2.1n 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206004 22-12 2:41p Accel No. 2 1/ 6 Octave ZPA. .67 gPk REQUIRED RESPONSE SPECTRA RRS Mile: Q12060BE.RRS 22-12 9:17a 10.0 7.0 5.0 4.0 3.0 2.0 .9 .7 -4 A c c e r a t i 0 u I I X, -.1+ I,-k 1.. I ,I.. 4 >~ ~G) Zn (g's) .5 .4 .3 .2 .1 2 3 4 5 6 7 8 10 Prequency Maert) 20 30 40 50 60 70 80 100 LZRPLOT Ver. 2. In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 79 TEST RESPONSE SPECTRA Data File: Q1206004 22-12 2.41p Accel No. 2 1/6 Octave ZPA:.67 gPk Required Response Spectra REQUIRED RESPONSE SPECTRA RRS File: Q1206OBFRRS 22-12 9:17a Freq Acccl L00 .35 3.00 L05 Fre2 20.00 Accel 1.05 35 100.00 Accel .35 .35 Test Response Spectra Freq 1.12 1.26 1.41 1.58 L78 zoo 2.24 2-51 2.82 336 3.55 3.98 4.47 5.01 5.62 6.31 7.08 7.94 8.91 10.00 11.22 12-59 14.13 15.85 17.78 1995 22.39 25.12 28.18 3L62 35.48 39.81 44.67 50.12 56.23 6310 70.79 79.43 89.13 100.00 .5%Damp GPk S4 [87 L06 1.15 83 180 1.55 3.01 2.18 2.80 3.59 4.84 3.12 2.84 2.75 2.40 4.06 4.64 3.26 3.25 3.64 249 2.12 2.62 3.34 6.38 4.76 2.73 [43 1.27 1.16 .94 .91 .78 .78 .86 80 .75 .76 .75 .70 2.0%Damp GPk .64 .96 .77 .70 .71 1.21 1.10 1.59 1.95 181 195 2.43 L77 1.72 2.24 L44 2.35 2-59 2.24 1.90 1.97 1.49 1.36 1.57 L90 332 2-73 1.83 112 1.17 1.04 £3 .83 .70 .72 .79 .75 .71 .72 .72 .67 3.0%Damp GPk .55 .80 .66 .60 .66 .99 .95 L25 1.69 1.52 155 1.85 1.50 1.48 1.94 1.32 1.92 2.09 [95 1.68 156 1.29 128 1L51 [79 286 2.38 1.59 [02 115 104 .83 S3 .70 .69 .77 .74 .72 .69 .69 .67 5.0%Damp GPk .44 .63 .52 51 .58 .76 .76 .94 132 1.22 1.11 136 1.29 1[30 1-57 120 1.41 L54 1[55 139 126 1.07 .18 138 1.58 2.21 1.96 1.38 .96 110 1.02 .84 .81 .70 .65 .74 .72 .71 .67 68 .67 7.0%Damp GPk 37 .53 .45 .45 .52 .63 .64 .80 1.06 1.07 .90 1.12 1.13 L14 133 112 1.16 1.24 1.29 1.20 1.12 .93 1.11 1.28 1.42 1.88 1.67 1.27 .98 1.06 .99 .84 £0 .70 .66 .72 .72 .70 .67 .67 .67 LZRPLOT Ver. 21n 03-22-2012

TEST RESPONSE SPECTRA Data *ile: Q1206004 22-12 2:41p Accel No. 3 1/6 Octave ZPA: .63 gPk REQUIRED RESPONSE SPECTRA RRS File: QI206OBE.RRS 22-12 9:17a 5.0 4.0 3.0 2.0 A c c e I e r a t i 0 n 1.0 .8 .6 .5 174-44.4 1-4 j...* ,1...

j.

I"* f iI i 1 4..1 j 77 7 4 i i_ N .I Zi .I. I..... .. '" " : i........ 3I 7 8 10 2*0 30 40, 0 on -yn A I 1 m Zvi (g's) .4 .3 .2 .1 v

  • v
  • v
  • v Frequency (Hertz)

LZRPLOT Vet. 2.In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 81 TEST RESPONSE SPECTRA Data File: Q1206004 22-12 2:41p REQUIRED RESPONSE SPECTRA Accel No. 3 V16 Octave ZPA .63 gPk RRS File: Q1206OBERRS 22-12 917a Required Response Spectra Freq Accel Freq Accel Freq Accel 1.00 .35 10.00 L05 50.00 .35 3.00 LOS 20.00 .35 100.00 35 Test Response Spectra Freq .5%Damp 2.0%Damp 3.0%Damp 5.0%Damp 7.0%Damp (hz) GPk GPk OPk GPk GPk 1.00 .58 .48 .38 .32 112 131 .77 .64 .51 .43 1.26 1.55 118 1.00 .75 .64 L41 L24 1.01 .90 .73 .61 1.58 L62 1.15 .95 .72 .60 178 L56 1.15 .97 .82 .70 2.00 2.28 1.35 1.08 .79 .69 2.24 2.62 155 1.26 .99 .5 2-51 2.79 L56 1-35 L04 .91 2.82 271 1.80 1.55 L25 1.06 3.16 3.58 1.98 1.57 1.13 .91 355 2.91 1.75 1.48 L18 1.01 3.98 2.48 1.87 L66 1.31 L08 4.47 3.18 1.84 L48 1.17 1.04 5.01 3.30 1.82 L68 L43 1.25 5.62 3.32 L91 1.54 1.30 1.9 6,31 2.37 1.72 1.55 1.29 1I1 7.08 3.01 1.94 1.75 L46 1.26 794 325 2.01 1.61 139 1.27 &91 4.77 2.14 L75 139 1.26 10.00 288 2.30 L96 1.52 1.26 11.22 4.12 2.05 L61 126 117 12.59 1.51 1.12 L02 .92 .85 1413 126 £89 .85 .84 .81 15.85 1.80 Ll .98 .86 .79 17.78 1.59 L06 .98 .90 .84 19.95 1.43 113 1.07 .98 .92 22.39 1.97 1.31 1.12 1.04 .97 2512 224 124 110 .94 .89 28.18 2.28 138 116 1.01 .93 31.62 127 .97 .91 .87 .85 35.48 1.54 1.05 .93 .83 .81 39.81 .97 .84 .83 .81 .79 44.67 .91 .82 .81 .78 .76 5012 .78 .77 .77 .75 .73 56.23 .82 .73 .71 A9 .68 6310 .77 .68 .67 .66 .66 70.79 .83 .74 .71 .69 69 79.43 .79 .73 .72 .70 69 89.13 .84 .74 .73 .71 .70 100.00 81 .70 .70 .69 .69 LZRPLOT Ver. 2in 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206004 22-12 2:4 1p Accel No. 4 1/6 Octave ZPA: 1.20 gPk REQUIRED RESPONSE SPECTRA RRS File: QI206OBE.RRS 22-12 9:17a A C C e r a t i 0 (g's) 25.0 10.0 7.0 5.0 3.0 2.0 1.0 .7 .5 ni.V-i I ~ Z } I X-I-Al t ~~ziizt ~ ~ TI 23 4 5 6 7 8 to 20 30 40 S0 60 70 90 I M PzC ~IE~EIEHE ~, FF~ .3 .2 .1 I0 Frequency (Hertz) LZRPLOT Ver. 2. In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix I1, Page No. 83 TEST RESPONSE SPECTRA Data File: Q1206004 22.12 2:41p REQUIRED RESPONSE SPECTRA Accel No. 4 1/ 6 Octave ZPA: 1.20 gPk RRS File: Q1206OBE.RRS 22-12 91-7a Required Response Spectra Freq Accel Fr* Accel Freq Accel L00 35 2.10 1.05 v .35 3.00 LOS 20.00 35 100.00 .35 Test Response Spectra Freq .5%Damp 2.0%Damp 3.0%Damp 5.0%Damp 7.0%Damp GPk GPk GPk GPk GPk .60 .50 .45 .39 .34 L12 1.61 1.13 .98 .74 .60 126 1.75 129

l.

.86 .72 L41 L70 1.01 .87 .77 .69 1.58 2.04 L18 1.02 .82 .68 1.78 1.59 L08 .91 .76 .68 2.00 2.07 130 113 .96 £5 2.24 2.14 1.44 128 1.15 1.01 2.51 1.57 1.27 113 .98 .90 2.82 3.28 1.95 1.64 131 1.13 3.16 430 2.40 L97 151 1.25 3.55 3.08 1.81 1.54 137 1.23 3.98 333 2.12 1.85 1.49 1.26 4.47 2.72 2.42 2.08 1.63 1.37 5.01 3.63 2.24 2.06 L76 1.53 5.62 4.81 2.26 1.92 1.66 1.45 631 4.09 2.94 2.67 224 1.93 7.08 5.06 3.06 2.66 2.19 1.89 7.94 5.50 4.16 3.55 2.76 2.28 8.91 6.00 3.42 3.11 2.51 2.12 10.00 5.23 3.51 3.23 2.81 2.45 1122 6.01 3.85 3.83 3.49 3.11 12.59 12.98 621 4.79 3.45 2.97 14.13 9.49 4.92 420 329 2.95 15.85 6.73 3.70 3.58 3.28 2.95 17.78 5.92 316 2.83 2.42 2.16 1995 3.17 2.23 2.06 1.87 L73 22.39 2.04 1.70 1.59 153 L49 25.12 1.96 1.53 L44 1.48 L46 28.18 2.08 L58 1.50 1.40 132 31.62 1.88 1.49 1.41 1.38 1.35 35.48 2.62 1.73 L58 1.40 1.37 39.81 2.59 1.94 1.79 1.58 1A9 44.67 L97 L48 L40 1.37 1-35 50.12 2.70 1.76 1.48 135 1.32 562.3 2.51 L77 L63 1.49 1.41 6310 2.45 2.05 1.86 1.65 1.53 70.79 2-46 L75 1.58 L48 L43 79.43 3.60 2.77 2.37 L90 170 89.13 4.23 2.78 2.36 195 1.79 100.00 199 177 1.69 167 1.65 LZRPLOT Ver. 2.1n 03-22-2012

TEST RESPONSE SPECTRA Data Pile: Q1206004 22-12 2 :4 1p Accel No. 5 1/6 Octave ZPA: 1.77 gPk REQUIRED RESPONSE SPECTRA RRS Fle: Q1206OBE.RRS 22-12 9:17a 50.0 30.0 20.0 10.0 7.0 ~HIIEER A cc e 1 e r a ti 0 n (g's) 5.0 3.0 2.0 1.0 .7 .5 .3 .2 .I .~~ ~ im. /. .0f,!" 2 3-4..78 0.30 50607 23 4 5 6 7 8 10 20 30 40 50 60 70 80 1C NP H 30 Frequency (Hertz) LZRPLOT Ver. 2. In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 85 TEST RESPONSE SPECTRA Data File: Q1206004 22-12 241p REQUIRED RESPONSE SPECTRA Accel No. 5 1/ 6 Octave ZPA 1.77 gPk RRS File: Q12060BE.RRS 22-12 9-17a Required Response Spectra Freq Accel Freq Accel Fr Acccl 10 .35 10.00 1.05 0 .35 3.00 1.05 20.00 35 100.00 .35 Test Response Spectra Freq .5%Damp 2.0%Damp 3.ODamp 5.0%Damp 7.0*oDamp (hz GPk OPk GPk GPk GPk 17 .67 .57 .44 -37 1.12 1.96 .99 .83 .65 .56 1.26 111 .81 .72 .57 A9 1.41 L25 .74 .65 .56 .50 158 102 .72 .67 .60 .56 L78 2.00 1.38 115 .90 .76 2.00 1.75 1.27 1.09 .87 .76 2.24 3.38 1.82 1.43 1.09 .95 2.51 2.49 2.20 1.86 1.41 1.14 2.82 3.56 2.41 2.06 1.60 L35 3.16 4.71 2.55 2.07 1.55 L26 3.55 6.20 314 2.51 1.90 1.59 3.98 4.56 2.59 2.30. 2.00 1.78 4.47 4.66 2.67 2.46 2.16 1.90 5.01 522 3-98 3.45 2.86 2.59 5.62 5.91 3.70 3.55 3.25 3.08 6.31 14.63 .8.67 7.13 5.79 4.88 7.08 27.07 1334 10.23 824 6.86 7.94 26.75 14.89 12.31 9.00 7.07 8.91 12.84 7.68 714 5.91 485 10.00 931 5.23 4,48 3.85 3.43 11.22 4.96 3.49 3.24 3.02 2.92 12.59 3.44 2.84 2.82 2.74 2.67 14.13 3.41 2.88 2.79 2.68 2.61 15.85 3.50 2.74 2.60 2.55 2.53 17.78 4.91 3.36 3.08 2.78 2.65 19.95 3.91 2.90 2.70 2-54 2.49 22-39 2.80 2.56 2.57 2.50 2.42 25.12 434 2.85 2.67 2.45 2-32 2818 5.61 3.22 2.83 2.42 221 31.62 3.62 2-67 2.40 2.17 2.14 35.48 4.25 2.68 2.44 2.24 2.11 39.81 2.68 2.20 2.11 2.02 1.98 44.67 311 2.25 2.19 2-10 2.04 50.12 2.44 2.48 239 2.26 2.18 56.23 2.86 234 2.30 2.26 221 63.10 3.17 Z55 2.43 2.27 2.16 70.79 2.00 1.83 1.82 1.80 1.86 79.43 2.77 2.71 2.56 2.32 2.18 89.13 2.91 2.68 2.54 2-35 2.22 100.00 2.52 L99 L99 L99 L98 LZRPLOT Ver. 21n 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206004 22-12 2 :4 1p Accel No. 6 1/6 Octave ZPA: .76 gPk REQUIRED RESPONSE SPECTRA RRS Mile: Q1206OBE.RRS 22-12 9:17a 10.0 7.0 5.0 4.0 3.0 2.0 .9 .7 At A c c e r a t i 0 n -} ~ ~.... (- ".*i.i. 12 3 4 5 6 7 8 10 20 30 40 50 6070 80 1(

o Sm CD Z

(g's) .5 .4 .3 .2 .1 )O Frequency (Hertz) LZRPLOT Ver. 2. ln 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 87 TEST RESPONSE SPECTRA Data File Q1206004 22-12 2.4 1p REQUIRED RESPONSE SPECTRA Accel No. 6 1/6 Octave ZPA..76 gPk RRS File: Q1206OBF-RRS 22-12 917a Required Response Spectra Fr Accel Fr Accel Freq Accel 35

10.

1.05 50.00 .35 3.00 L05 20.00 35 100.00 .35 Test Response Spectra Freq .5%Damp 2.0%Damp 3.0%Damp 5.0%Damp 7.0%Damp z0 GPk GPk GPk GPk GPk L 1.08 .65 .54 .43 36 1.12 139 .82 .70 .56 .47 1.26 1.66 126 1.07 .80 .68 1.41 136 1.10 .98 .79 .66 1-58 178 L26 L04 .79 .66 1.78 1.68 123 1.06 .89 .77 2.00 2.46 L46 116 .84 .76 2-24 2.86 L68 136 1.08 .93 2.51 2.99 1.71 1.47 1.12 .98 2.82 2.93 1.92 1.66 135 114 3.16 3.78 210 1.66 1.20 .97 3.55 3.00 1.92 1.60 126 1.07 3.98 2.74 1.98 1.76 137 L16 4.47 334 2.00 1.60 L28 1.14 5.01 3.48 2.01 1.84 1.57 1.37 5.62 3.62 212 1.71 1.43 131 6.31 2.53 185 1L69 L41 1.23 7.08 3.27 2.04 L85 1.55 135 7.94 3.52 2.23 1.82 1.59 1.45 8.91 534 234 L95 L56 145 10.00 332 264 2.24 1.76 1.46 11.22 4.86 238 1.85 1.40 1.29 1259 189 1.29 1.16 1.07 .97 14.13 1.43 L09 L09 1.04 .98 15.85 314 180 1.51 1.20 106 17.78 236 134 L24 1.07 .98 19.95 1.49 L19 1.15 1.09 L03 22.39 2.45 164 L40 1.13 107 25.12 L69 108 1.09 1.05 .99 2818 2.06 115 1.07 .95 .87 31.62 1.49 102 .93 .84 .82 35.48 116 .88 .84 .80 .80 39.81 1.07 .87 .84 .82 .81 44.67 1.59 122 1.13 .99 .88 50.12 L64 1.28 1.12 .92 .81 56.23 L08 .85 £2 .80 .79 63.10 .99 .85 .83 .81 .80 70.79 1.54 142 1.28 1.07 .92 79.43 2.16 1.56 133 1.09 .93 89.13 137 1.14 1.06 .96 .89 100.00 1.34 L13 101 .96 .92 LZRPLOT Ver. 2.1n 03-22-2012

TEST RESPONSE SPECTRA Data FMle: Q1206004 22-12 2 :4 1p Accel No. 7 1/6 Octave ZPA: 1.16 gPk REQUIRED RESPONSE SPECTRA RRS Pile: Q1206OBE.RRS 22-12 9:17a 25.0 - LrnzI IEfEV~E II P1~1 [~H~ [i~ I t I I i~. I FIT.1

t IT' I

10.0 7.0 5.0 I I /I .i _ F, ý, I V 4-. I; IX I I ! I t I '-t I/F N. \\.* -- : 1. k / V'T-'V N; A C c 3.0 e e 2.0 ti 0 n 1.0 (g's) .7 .5 r ý0 N.- i I Ll i..'. I.. f 4- -if i-.-' I- -- I.A, J I p. EL I I

o d

.3 .2 .1 2 3 4 5 6 7 8 10 Prequency (Hertz) 20. 30 40 50 60 70 80 100 LZRPLOT Ver. 2. In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 89 TEST RESPONSE SPECTRA Data File: Q1206004 22-12 141p REQUIRED RESPONSE SPECTRA Accel No. 7 1/6 Octave ZPA 1.16 gPk RRS File: Q1206OBE.RRS 22-12 9.17a Required Response Spectra Freq Accel Freq Accel Freq Accel 1O0 35 10.00 LO5 50.00 35 3.00 1.05 20.00 35 100.00 35 Tcst Response Spectra Freq .5%Damp 2.0%Damp 3.0%Damp 5.0%Damp 7.0%Damp (hz) GPk GPk GPk GPk OPk 1.0 .55 .45 .41 .36 .32 1.12 L69 1.12 .95 .73 .59 1.26 L75 L29 110 .86 .73 1.41 .162 .96 .86 .76 .68 1.58 189 120 L03 .80 .66 L78 1.50 1.08 .90 .75 .67 2.00 2.15 L36 1.18 .99 .85 2.24 2.15 1.47 1.27 1.16 L03 2.51 1.48 1.25 1.14 .99 .91 2.82 3.30 L96 1.65 1.31 1.12 3.16 4.11 2.33 L93 1.48 L22 3.55 3.01 1.74 1A9 L35 L20 3.98 3.13 2.09 1.83 1.48 1.25 4.47 2.77 2.41 2.06 1.59 1.33 5.01 3.55 2.19 1.99 1.69 147 5.62 4.93 2.31 1.97 L69 L47 6.31 4.29 3.04 2.72 2.27 1.96 7.08 4.39 2.82 2.49 2.09 1.88 7.94 6.03 425 3.59 2.77 2.29 8.91 6.10 3.42 3.05 2.47 2.09 10.00 529 3.55 331 2.86 Z49 1122 6.33 3.85 385 3.51 3.13 12.59 1337 6.40 4.92 3.55 2.89 14.13 9.5 4.98 4.26 3.41 2.93 15.85 7.43 4.09 3.75 335 2.96 17.78 6.50 3.72 3.26 2.71 2.37 19.95 5.98 333 2.82 2.43 2.19 22.39 420 3.15 2.78 229 1.98 25.12 3.47 2.45 2.23 L92 1.87 2818 4.48 2.84 2.61 2.33 2.14 3L62 10.61 538 4.40 3.49 2.83 35.48 9.61 4.98 4.37 3.51 2.94 39.81 4.60 3.11 2.83 2.42 2.14 44.67 3.03 2.23 2.04 1.74 L62 50.12 2.62 2.04 179 1.54 1.46 56.23 2.24 L73 159 L45 1.39 63.10 2.40 187 L75 1.56 1.43 70.79 2.03 1.54 1.47 1.38 134 79.43 224 L79 L66 1.47 135 89.13 2.87 Z08 1.86 1.59 1.45 100.00 3.52 2.16 189 1.63 L47 LZRPLOT Ver. 2.1n 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206004 22-12 2 :4 1p Accel No. 8 1/6 Octave ZPA: 1.44 gPk REQUIRED RESPONSE SPEC!TRA RRS FMe: Q12060BE.RRS 22-12 9:17a 25.0 10.0 7.0 5.0 3.0 2.0 1.0 A c c e 1 e r ati 0 o I t I 1-1 ~izL+/-LIN -ttI LL I~ {i CDI Im C26 (g's) .7 .5 .3 .2 .1 I 2 3 4 5 6 7 8 10 20 30 40 50 60 70 80 100 Frequency (Hertz) LZRPLOT Ver. 2.In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix 11, Page No. 91 TEST RESPONSE SPECTRA Data File-0Q1206004 22-12 2.41p Accel No. 8 1/6 Octave ZPA: 1.44 gPk REQUIRED RESPONSE SPECTRA RRS File: Q1206OBE.RRS 22-12 9:17a Required Response Spectra Freq Accel Fre t00 35 10.00 3.00 L05 20.00 Test Response Spectra Accel 1.05 .35 100.00 Accel .35 35 Freq 1.12 [26 1.41 1.58 1.78 2.00 224 2-51 2.82 316 3-55 3.98 4.47 5.01 5.62 631 7.08 7.94 8.91 10.00 11.22 12.59 14.13 15.85 17.78 19.95 2239 25.12 2818 31x62 35.48 39.91 44.67 5012 5623 6310 70.79 79.43 89.13 100.00 .5%Damp GPk .86 1.92 1.07 1.18 .90 L93 L68 3.27 2.47 3.47 4.53 6.11 438 4.42 5.01 5.64 13.57 24.55 24.02 1126 8.19 4.04 3.01 2.98 2.54 3.66 2.66 2.94 2.59 2-03 201 2.14 L72 L99 1.75 2.59 2.84 2.48 2.50 2.77 2.60 2.0%Damp GPk .67 L04 .77 .74 .79 131 119 1.74 2.15 2.32 2.46 3.05 2-53 2.54 184 141 &03 12.09 1333 6.74 4.62 2.92 2.44 2.27 1.99 2.48 221 2.13 2.01 1.79 L69 1.84 1.56 1.57 158 189 2.27 216 2.25 2.30 2-12 3.0%Damp GPk .57 .86 67 .67 .73 109 L02 1.38 183 t98 L99 2.42 223 2.38 329 331 6.54 9.27 1102 635 4.00 2.66 2.44 223 194 2.30 2.12 193 1.98 1.70 167 1.78 1_53 1.48 1.58 1.77 2.14 2.11 2.13 2.14 1.97 5.0%Damp GPk .45 .68 .57 .58 .64 .4 .81 L05 1.41 1.53 1.49 1.84 1.93 2.09 2.73 3.02 531 7.42 &06 524 3.45 2.57 2.40 2-19 1.93 2.13 1.96 1.84 1.90 1.62 162 1.69 148 1.48 1.56 1.67 198 2.01 192 1.91 1-77 7.0%Damp GPk .38 .57 .49 .52 .58 .70 .72 .95 1.13 133 121 1.54 1-71 1.83 2.40 2.84 4.48 6.19 6.33 430 3.10 2.52 2.35 2.16 1.94 2.03 1.90 1.82 L84 1.61 158 L63 L48 L47 1.53 L61 187 1.91 L76 L78 1.73 LZRPLOT Ver. 2-1n 01-22-2012

TEST RESPONSE SPECTRA Data Pile: Q120600 4 22-12 2 :4 1p Accel No. 9 1/6Octave ZPA: 1.09 gPk REQUIRED RESPONSE SPECTRA RRS Pile: QI206OBE.RRS 22-12 9:17a 25.0 10.0 7.0 5.0 A c c 3.0 e o 2.0 ra t 0 n 1.0 (g's) .7 .5 .3 .2 .1 J-A. I. V I Iu~i 7 T r9 or_ _ Zn.: 9'9 zo I 2 3 4 5 6 7 8 10 Rrequency (Heilz) 20 30 40 50 60 70 80 100 LZRPLOT Ver. 2.lIn 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 93 TEST RESPONSE SPECTRA Data File: Q1206004 22-12 2141p Accel No. 9 1/ 6 Octave ZPA: 1.09 gPk REQUIRED RESPONSE SPECTRA RRS File: Q1206OBERRS 22-12 9:.17a Required Response Spectra Fre Accel Fre -35 10.0 3.00 LOS 20.00 Test Response Spectra Accel L05 35 Freq 50.00 100.00 Acccl .35 35 Freq L12 126 1.41 158 178 2.00 224 2.51 2.82 3.16 3.55 3.98 4.47 5.01 5.62 6.31 7.08 7.94 &91 10.00 11.22 12.59 14.13 15.85 17.78 19.95 22.39 25.12 2818 31.62 35.48 39.1 44.67 50.12 56.23 6310 70.79 79.43 89.13 100.00 .5%Damp GPk .55 1.61 1.73 1.58 1.82 L48 207 2.03 1.41 3.06 4.03 2.83 2.92 2.70 3.24 4.40 3.82 4.41 4.89 5.38 4.47 5.08 10.13 7.10 4.46 3.41 1.68 1.55 2.14 2.10 321 3.69 3.86 2.71 330 2.13 2-56 3.01 4.07 3.98 3.89 Z.0%Damp QPk .46 U11 127 .94 1.13 1.06 1.33 1.39 121 1.86 224 L62 L99 2.34 2.06 2.06 2.75 2-70 3.69 2.97 3.00 3.10 4.90 3.66 2.77 228 131 1.26 137 1.67 198 2.46 2.47 1.90 2.60 1.90 1.90 1.73 2.44 2.68 2.08 3.0%Damp GPk .41 .96 1.08 .83 .96 .89 1.15 L27 1.10 1.58 1.85 1.48 1.75 1.99 192 L79 2.48 234 3.16 2.71 2.68 3.01 3.83 3.15 2.63 2.05 1.25 1.20 1.27 1.52 1.70 223 2.26 180 2-30 1.80 1.76 1.58 2.10 223 1.84 5.0%Damp OPk 36 .74 .83 .74 .77 .71 .96 L14 .97 125 1.41 1.31 1.42 153 1.63 1.55 2.08 1.92 247 2.19 232 2.75 2.76 250 2-38 L78 122 1.16 124 135 1.58 L84 1.91 1.74 L90 L66 1.57 1.42 1.75 1.77 1.56 7.0%Damp GPk 32 .60 .70 .66 .64 .63 S4 L00 .89 1.07 1.16 116 1.20 127 L42 137 1.80 1.65 2.04 1.84 2.01 2.45 2.28 2.19 2-14 1.61 120 114 1.23 133 1.51 1.61 1.67 L69 1.79 156 144 138 L49 1.50 1.41 LZRPLOT Ver. 2.ln 03-22-2012

TEST RESPONSE SPECTRA Data FUe: Q1206004 22-12 2:4 1p Accel No. 10 1/6 Octave ZPA: 1.79 gPk REQUIRED RESPONSE SPECTRA RRS Mile: QI206OBF-RRS 22-12 9:17a 25.0 10.0 7.0 5.0 A Cc 3.0 I e 2.0 r a t n 1.0 (Wus) .7 .5 .3 .2 .1 ~ ~~~~~ ~ ~ ~ ~ ~ E*- )-

i.

.7-f! i I I i i i i i If, f, I -I kYt I\\ I / i I*fIN/ I I 1', I

  • ~~

~ T --T] I-- 1 T I: 2-i 7J CG) I 2 4 5 6 7 8 ID 2030 403 50 60 708 1100 Preqtlency (He=t) LZRPLOTVer.2, In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 95 TEST RESPONSE SPECTRA Data File: Q1206004 22-12 2141p REQUIRED RESPONSE SPECTRA Accel No. 10 1/6 Octave ZPA: L79 gPk RRS File Q1206OBE.RRS 22-12 917a Required Response Spectra FPr Accel Fr Accel Fre Accel .35

10.

1.05

50.

.35 3.00 1.05 20.00 .35 100.00 .35 Test Response Spectra Freq .5%Damp 2.0%Damp 3.0%Damp 5.0%Damp 7.0%Damp

  • 0)

GPk OPk GPk GPk GPk .86 .66 .57 .45 .37 112 1.94 L02 .86 .67 .57 1.26 L08 .79 .69 .56 .49 1.41 1.20 .73 .66 .57 .50 1.58 .88 .79 .73 .64 .58 1.78 195 1.33 1-10 .84 .70 2.00 167 1.18 [00 .80 .70 2.24 330 1.75 137 1.03 .89 2.51 Z48 Z15 1.83 140 L15 7-82 330 2.22 1.89 L46 128 3.16 4.35 2.33 1.89 1.41 114 3.55 5.87 2.92 2.31 1.75 1.45 398 4.09 2.33 2.10 L82 1.62 4.47 4.11 2.35 2.16 [91 1.68 5.01 4.55 3.52 3.02 2.49 2.11 5.62 4.92 2.98 2.77 2.45 231 631 11.43 6.71 5.46 4.42 3.72 7.08 19.73 9.79 7.53 5.80 4.85 7.94 1858 10.14 8.40 6.15 4.84 &91 &56 5.11 4.79 3.97 3.27 10.00 5.79 3.40 2.95 2.51 2.27 1122 2-99 2.16 2.04 1.99 1.96 12.59 2-30 1.92 1.90 186 1.81 14.13 2.47 2.10 L97 1.82 1.74 15.85 2.72 1.96 1.83 1.72 L66 17.78 2.68 2.01 1.80 1.72 169 19.95 3.27 236 211 1.88 1.79 22.39 3.68 2.26 2.07 1.81 1.65 25.12 2.80 1.67 1.55 L40 134 2&18 2.48 1.82 1.60 L49 1.43 3L62 2.39 181 1.75 165 1.55 35.48 2.30 177 [68 [58 1.51 39.81 236 178 1.67 1.60 1.57 44.67 2.85 233 2.21 2.05 1.93 50.12 2.83 2.66 2.53 2.34 218 5623 2.49 231 228 2.17 2.12 63.10 4.78 3.34 2.97 2.59 2.39 70.79 7.45 416 3.46 2S5 2.68 79.43 5.70 4.38 4.04 3.50 3.22 89.13 8.03 537 4.64 3.87 3.46 100.00 12.06 5.56 4.49 3.50 3.24 LZRPLOT Ver. 2.ln 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206004 22-12 2 :4 1p Accel No. 11 1/6 Octave ZPA: 1.08 gPk REQUIRED RESPONSE SPECTRA RRS File: QI206OBE.RRS 22-12 9:17a 10.0 7.0 5.0 4.0 3.0 III I . I I i I A c c e I e r at. 0 n (g's) 2.0 .9 .7 .5 .4 .3 .2 .1 if I IA I I" I I I IVI !l L '"I o li .,~ ~ J .1 m C, I 2 3 4 5 6 7 8 10 20 Frequency MHertz) 30 40 50 60 70 80 100 LZRPLOT Ver. 2. In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 97 TEST RESPONSE SPECTRA Data Fileb Q1206004 22-12 241p REQUIRED RESPONSE SPECTRA Accel No. 11 1/6 Octave ZPA: 1.08 gPk RRS File: Q1206OBERRS 22-12 9:17a Required Response Spectra Freq Accel Fre Accel Freq Accel 1.00 .35 10.00 L05 50.00 35 3.00 105 20.00 .35 100.00 -35 Test Response Spectra Freq .5%Damp 2.0%Damp 3.0%Damp 5.0%Darap 7.0%Damp (G) GPk GPk GPk GPk GPk 1.00 106 .60 .49 .39 33 1.12 L40 .82 .67 .53 .45 1.26 1.55 1.19 1.01 .76 .66 1.41 125 1.02 .91 .74 .61 158 1.69 1.19 .99 .75 .62 L78 1.65 121 1.02 .83 .71 2.00 2.31 1.38 111 .80 .72 2.24 2764 1.57 1.28 1.00 .86 2.51 2.86 1.59 137 110 .96 2.82 2-70 1.83 1.59 1.29 1.10 3.16 3.62 1.99 158 1.13 .92 3.55 2.87 1.69 1.41 1.19 1.03 3.98 2.53 1.82 1.63 1.29 LIO 4.47 325 1.90 1.54 L17 1.04 5.01 3.39 182 1.67 1.41 1.23 5.62 3.42 L99 1.61 1.26 U6 6.31 2.59 1.86 171 143 120 7.08 3.38 2.04 1.79 L47 1.28 7.94 3.27 1.95 1.68 1.33 118 8.91 5.01 2.28 1.87 L49 1.28 10.00 3.23 2.49 2.12 1.65 138 1122 4.61 2.21 L71 125 L15 12.59 1.89 L25 1.10 .96 89 14.13 139 LO0 .99 .94 .89 15.85 2.66 145 1.29 110 .98 17.78 2.03 1.29 1.15 1.05 .98 19.95 1.38 1.30 125 1.16 1.08 2239 2.50 1.69 1.44 1.28 1.18 25.12 2.70 L53 138 119 1.12 28.18 2.89 L68 1.46 L25 11 3162 L98 1.30 109 1.02 .99 35.48 1.71 1.23 1.13 .98 .91 39.81 1.41 114 1.08 .97 .89 44.67 L71 1.36 1.24 1.12 L03 50.12 1.70 1.42 1.30 1.17 L09 56.23 2.48 2.07 1.89 1.59 1.40 63.10 2.70 2.19 L96 1.63 1.41 70.79 2.82 2.21 214 202 1.92 79.43 5.34 3.91 3.37 2.58 2.23 89.13 5.63 4.61 4.01-3.26 2.74 100.00 5.84 3.31 3.02 2.49 2.28 LZRPLOT Ver. 2.1n 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206005 22-12 2:43p Accel No. 1 1/6 Octave ZPA: .53 gPk REQUIRED RESPONSE SPECTRA RRS File: Q12060BE.RRS 22-12 9:17a 5.0 4.0 3.0 2.0 A c e1 e r a t i 0 C 1.0 .8 .6 .5 F 1.1 r- -4 v A .......... ý- " * ý,l T. ...... e l.......... -00;r !0-0 k op a CD bo (g's) .4 .3 .2 .1 I Z 1 4 0 I 7s IV LU Frequency (Hertz) LZRPLOT Ver. 2.in 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No.99 TEST RESPONSE SPECTRA Data File: Q1206005 22-12 2.43p REQUIRED RESPONSE SPECTRA Accel No. 1 1/ 6 Octave ZPAk .53 gPk RRS Filc: Q1206OBERRS 22-12 9,17a Required Response Spectra Fir Accel Fre Accel Fre Accel .35

10.

1.05 50.00 .35 3.00 1.05 20.00 35 100.00 .35 Test Response Spectra Prq* .5%Damp 2.0%Damp 3.0%Damp 5.0%YDamp 7.0%Damp GPk GPk OPk GPk OPk OO .55 .45 .41 .36 .32 1.12 161 1.10 .95 .73 .59 126 171 1.27 1.08 .84 .70 1.41 1.59 .95 .84 .74 .66 1.58 1.80 L13 .97 .76 .63 178 1.44 1.06 £8 .72 .63 2.00 2.04 1.29 1.12 .93 .81 2.24 2.03 L40 1.20 1.09 .96 2.51 132 116 106 .94 .86 2.82 3a08 1.83 153 121 1.04 3.16 3.82 215 1.77 135 1-11 3.55 2.74 154 136 124 1.10 3,98 2.80 1.94 171 138 1.16 4.47 262 2.23 1.90 L45 119 5.01 3.02 1.93 1.74 1.42 1.21 5.62 3.89 1.88 1.55 1.34 1.20 6.31 3.46 2.36 2.09 1.73 L48 7.08 3.39 2.11 1.85 1.54 L34 7.94 3.62 2.72 2.32 1.8i 150 8.91 3.72 2.05 1.85 1.47 1.23 10.00 2.94 2.10 1.79 1.39 1.17 1122 2.35 134 131 120 L08 12.59 3.77 1.90 154 1.17 LO0 14.13 1.78 1.39 126 L08 .98 15.85 1.47 .98 .96 .91 .86 17.78 2.23 L28 .11 .91 .80 19.95 1.78 .99 .89 .78 .74 2239 1.65 L09 .96 .80 .74 25.12 1.12 .90 .85 .79 .75 2818 .87 .75 .73 .69 .70 3162 .92 .85 .82 .78 .75 35.48 .93 .80 .77 .74 .72 39.81 .76 .67 .67 .66 .66 44.67 .69 .66 .65 .64 .64 50.12 .66 .65 .65 .64 .63 5623 .77 .61 .58 .59 .59 63.10 .76 .62 .59 .57 .56 70.79 .65 .56 .55 .54 .53 79.43 .65 .57 .56 .55 .54 89.13 .66 .58 .57 -56 .55 100.00 .70 .62 .59 .57 .57 LZRPLOT Ver. 2.1n 03-22-2012

TEST RESPONSE SPECTRA Data File: Q120600 5 22-12 2 :4 3p Accel No. 2 1/6 Octave ZPA: .70 gPk REQUIRED RESPONSE SPECTRA RRS ile: QI206OBE.RRS 22-12 9:17a 10.0 7.0 5.0 4.0 3.0 2.0 .9 .7 ýxI;\\ . I..... F I M -: 1 i I z A c e 1 e r ati 0 n I 1;...

4.

.o 4 .5 8 to 20 30 40 50 60 70 80 1 C) 00 @0 (gs) .5 .4 .3 .2 .1 I0 _v v_ Frequency (Hertz) LZRPLOT Ver. 2.1n 03-22-2012

Report No. EGS-TR-HC589-01 Appendix 11, Page No. 101 TEST RESPONSE SPECTRA Data File: 01206005 22-12 2:43p Accel No. 2 1/6 Octave ZPA .70 gPk Required Response Spectra Fr.q Accel Fre Accel Freq Accel 1 35 10.00 1.05 50.00 .35 3.00 1.05 20.00 .35 100.00 .35 REQUIRED RESPONSE SPECTRA RRS File: Q12060BE.RRS 22-12 9:17a Test Response Spectra Freq .5%Damp (hL) GPk .83 112 1.87 126 1.05 141 .17 158 85 1.78 1.77 2.00 152 2.24 3.02 2.51 2.15 282 2.77 316 3.54 3.55 4.79 3.98 3.06 4.47 2.75 5.01 2.78 5.62 2.33 631 4.11 7.08 4.54 7.94 3.20 8.91 3.02 10.00 3.57 1122 2.52 12.59 2.05 14-13 2.81 15.85 3.58 17.78 6.22 19.95 4.72 2239 2.25 25.12 1.48 28.18 1.37 3L62 1.15 35.48 1.13 39.81 .98 44.67 .76 50.12 .84 56.23 .84 63.10 .92 70.79 .78 79.43 .76 89.13 £3 100.00 .72 2.0%Damp 3.0%Damp 5.0%Damp GPk GPk GPk .63 .54 .43 .94 .79 .62 .76 .65 .52 .71 .61 .51 .71 .66 .58 1.20 .98 .75 L09 .93 .75 L60 1.26 .94 1.93 1.67 130 1.79 150 1.21 L92 153 Uo 2.41 184 135 1.75 1.50 L28 1.69 L46 1.29 2.23 193 156 1.42 131 122 2.36 L90 1.40 2.55 2.08 154 2.19 L90 1.51 1.91 1.71 1.42 1.88 1.49 1.20 1.46 127 1.05 133 L24 L13 1.50 137 127 2.07" L85 169 3.66 325 2.53 2.72 2.37 L96 1.67 L57 1.42 1.15 L05 .94 L22 L17 110 .11 1.10 L06 .83 .86 .89 .90 .89 .88 .76 .78 .79 .79 .77 .74 .72 .72 .72 £82 .80 .78 .74 .73 .73 .75 .74 .73 .75 .73 .72 .69 .69 .70 7.0%Damp GPk 36 .52 .46 .45 -52 .62 .63 .80 105 1.06 .88 w11 1.12 113 1.33 1.13 1L15 1.26 1.25 1.22 1.07 .92 1.06 1.18 1.55 2.14 1.68 L32 .98 1.07 1.03 .90 .87 .78 .73 .71 .76 .73 .73 .72 .70 LZRPLOT Ver. 2.1n 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206005 22-12 2 :4 3p Accel No. 3 16 Octave ZPA: .63 gPk REQUIRED RESPONSE SPECTRA RRS PMle: Q1206OBE.RRS 22-12 9:17a 5.0 4.0 3.0 2.0 A c C e1 e r a t i 0 n1 1.0 .8 .6 .5 t \\d/ -IT I i f F... P IIL r .....~~~~. ' *i*! ..÷...... 23 4 5 6 7 8 10 20 30 40 50 60 70 80 10 m (D4 z x (gs) .4 .3 .2 .1 Frequency (Hertz) LZRPLOT Vet. 2. In 03-22-2012

Report No. EGS-TR-HC589-0i Appendix II, Page No. 103 TEST RESPONSE SPECTRA Data File: Q1206005 22-12 1-43p REQUIRED RESPONSE SPECTRA Accel No. 3 1/6 Octave ZPA..63 gPk RRS File: Q1206OBERRS 22-12 9:17a Required Response Spectra Fr.q Accel Freq Accel Freq Accel 35 1000 L05 50.00 35 3.00 1.05 20.00 .35 100.00 .35 Test Response Spectra Freq .5%Damp 2.0%Damp 3.0%Damp 5.0%Damp 7.0%Damp (hz) GPk GPk GPk GPk GPk 1.00 1.01 .58 .48 .38 .32 U12 1.32 .78 .64 .52 .43 126 1.53 1.16 .99 .74 .64 1.41 1.27 1.03 .91 .73 .61 1.58 1.59 1.15 .95 .72 .60 1.78 1_59 117 .99 .82 .70 2.00 2.26 1.34 1.08 .78 .70 2.24 2.65 1.56 1.27 660 .86 2.51 2.79 L57 1.35 1.05 .92 2.82 2.76 1.81 1.56 126 L07 316 3.54 1.97 1.57 1.13 .91 3.55 2.90 L75 L48 1.18 1.02 3.98 2.48 1.86 166 1.31 108 4.47 3.22 1.87 1.51 1.18 1.06 5.01 329 1.84 1.69 1.44 1.26 5.62 3.36 1.95 1.58 1.30 1.19 6.31 2.39 1.75 159 132 1.12 7.08 3.01 L94 L76 1.47 1.27 7.94 3.29 zoo L60 138 1.26 8.91 4.88 2.16 1.77 1.41 1.25 10.00 2.79 Z26 193 1.51 1.26 11.22 4.12 2-04 1.59 1.32 1.18 12.59 157 113 104 .95 .90 14.13 119 .93 .90 .81 .75 15.85 1.84 LU 1.00 .86 .77 17.78 1.70 L07 .96 .85 .81 19.95 132 1.17 1.10 L01 .93 2239 1.98 1.25 1.16 1.07 1.oo 25.12 228 1.37 1.22 1.00 .89 2818 2.07 1.50 136 113 .98 31.62 126 1.04 LOO 94 .92 35.48 1.29 1.05 1.02 .98 .94 39.81 .98 1.01 .99 .96 .93 44.67 1.16 108 1.03 .97 .92 50.12 .94 .93 .90 .86 .83 56.23 .83 .74 .73 .73 .72 63.10 .78 .72 .71 .69 .68 70.79 .75 .71 .70 .69 .69 79.43 .67 .71 .71 .70 .69 89.13 .75 .68 .69 .69 .68 100.00 .73 .65 .65 .66 .66 LZRPLOT Ver. 2.ln 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206005 22-12 2 :4 3p Accel No. 4 1/6 Octave ZPA. 1.17 gPk 25.0 i I REQUIRED RESPONSE SPECTRA RRS File: Q12060BE.RRS 22-12 9:17a ~Izt:t~2ztzU!~1Th 1~~~ ti-ti 10.0 7.0 5.0 A c C C a t i 0 n (g1s) 3.0 2.0 1.0 .7 .5 It --Ef I Yt.. W :ý-A-J4 Mk A.. 54t Lil-I I I 4- -- 7 1 I - -T-L T-L (D ;p Z X .3 .2 .I 3 4 5 6 7 8 10 Frequency (Hertz) 20 30 40 50 60 70 80 100 IZRPLOT Ver. 2. In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 105 TEST RESPONSE SPECTRA Data File: 01206005 22-12 2.4 3p Accel No. 4 1/6 Octave ZPA: 1.17 gPk Required Response Spectra REQUIRED RESPONSE SPECTRA RRS File-Q1206OBERRS 22-12 917a Freq L0O 3.00 Accel .35 L05 F 20.00 Accel 1.05 .35 100.00 Accel .35 35 Test Response Spectra Freq (hz) 1O0 112 1.26 1.41 1.58 178 2.00 2-24 2751 2.82 3.16 3.55 3.98 4.47 5.01 5.62 631 7.08 7.94 &91 10.00 1122 12.59 14.13 15S5 17.78 19.95 22.39 25-12 2&18 3X62 35.48 3981 44.67 50.12 56.23 63.10 70.79 79.43 8913 100.00 .5%Damp OPk .58 1L60 1.76 1.71 1.98 L56 2.08 2,16 L49 3.32 418 3.12 331 2.74 3.73 4.82 4.07 5.03 5.45 5.99 5.84 6.53 13.53 9.08 6.24 5.67 2.91 2.23 1.98 2.14 1.96 316 2.60 1.78 2.46 2.13 211 2.94 3.73 439 1.76 2.0%Damp GPk .48 1.11 1.30 1.02 1.20 1.09 1.28 1.45 1.26 1.97 2.34 L80 2.13 2.45 2.25 2.26 2.89 3.03 4.09 3.47 3.82 3.94 6.75 5.40 3.96 3,53 1.95 1.74 1.56 1.59 1.58 1.93 1.91 L48 L65 1.63 1.64 1,75 2.69 2-84 1.61 3.0%Damp GPk .43 -96 112 .90 1.04 .92 LI1 125 1.4 L66 1.93 1.51 186 2.10 2-10 1.93 2.61 2.63 3.51 3.14 3.36 3.91 5.40 4.75 3.84 314 L84 166 1M45 1.52 1.54 170 1.73 L48 L52 1.48 1.58 1.58 2.33 2.34 L57 5.0%Damp GPk .37 .74 .87 .79 .3 .75 .93 L13 .99 132 1.48 139 t50 1.64 1.79 1.67 219 2-16 2.75 2.51 291 3.58 3.89 3.78 3.50 2.67 1.71 1-54 143 139 1.47 1.55 154 1.45 1-35 1.40 146 L43 190 190 1.51 7.0%Damp GPk 33 .60 .73 .71 .69 .67 .81 .00 .90 112 L23 1.25 127 137 1.56 1.47 1.89 1.87 2.28 2.10 2-55 3.19 3.09 321 3.15 2.37 1.66 145 1.40 129 L41 L44 1.47 1.41 1.31 136 1-36 139 168 L76 1.50 LZRPLOT Ver. 21n 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206005 22-12 2 :4 3p Accel No. 5 116 Octave ZPA: 1.75 gPk REQUIRED RESPONSE SPECTRA RRS Ple: QI206OBE.RRS 22-12 9:17a 50.0 30.0 20.0 10.0 7.0 -.1. - ~ A C c e r a t i 0 nt 5.0 3.0 2.0 .I ____~~~~~.. I~~ w i I - - -l zm (g's) 1.0 .7 .5 .3 .2 .1 2 3 4 5 6 7 8 10 20 30 40 50 60 70 80 100 Frequency (Hertz) LZRPLOT Ver. 2.In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 107 TEST RESPONSE SPECTRA Data File: Q1206005 22-12 2.43p Accel No. 5 1/ 6 Octave ZPA: L75 gPk REQUIRED RESPONSE SPECTRA RRS File: Q1206OBERRS 22-12 917a Required Response Spectra Fr. Accel Freq o .35 10.00 Tes0 Los 20.00 Test Response Spectra Accel L05 .35 100lO. Accel 35 .35 Freq L12 L26 141 158 1.78 2.00 2.24 2-51 2.82 316 3.55 3.98 4,47 5.01 5.62 6.31 7.08 7.94 8.91 10.00 1122 12.59 14.13 15.85 17.78 19.95 2239 25.12 28.18 31.62 35.48 39.81 44.67 50.12 5623 63.10 70.79 79.43 89.13 100.00 .5%Damp OPk .88 1.93 1.15 L24 .96 1.96 1.64 3.30 2.51 356 4.61 6.13 4.41 4.61 5.13 5.88 14.88 26.26 27.30 12.40 9.54 5.01 3.37 3.54 3.52 4.73 3,81 3.34 4.48 521 3.63 437 2.83 280 2.46 2.84 3.17 2.33 2.76 3.10 2.41 2-0%Damp OPk .68 L01 .79 .75 .75 1.35 1.20 L79 2.19 238 2.52 3.11 2.61 2.71 3.88 3.52 &79 13.05 15.04 7.67 5.31 3.47 2.75 2.92 2.73 3.39 2.74 2.62 3.00 3.37 2.92 2.76 223 2.12 237 239 2.63 L99 2.42 2.59 198 3.0%Damp GPk .58 .84 .69 .65 .71 1.12 1.03 1.41 1.84 2-03 2.06 2.48 2.30 2.43 3.44 353 7.20 1028 12.32 7.12 4.52 322 2.72 2.84 2.72 3.09 2.57 2.64 2.79 2.87 2.50 2.52 2.11 2.10 2.32 2.27 2.47 [91 227 2.43 186 5.0%Damp GPk .45 .67 .55 .55 .63 .87 .83 1.07 [39 1.58 1.54 1.89 1.99 213 2.89 3.26 5.84 8.38 8.93 5.89 3.85 3100 2.64 2-72 2.66 2.77 2.43 2.55 2.53 2-51 2.24 2.27 2.01 2.05 222 2.18 2.27 1.86 2.07 221 1.81 7.0%Damp GPk .38 .56 .48 .50 .58 .73 .74 .95 1.13 L34 1.26 1.59 1.77 L88 Z61 3.09 4.92 6.97 6.99 4.82 3.39 2.90 2.62 2.65 2.60 2.60 2.42 2.46 2.38 2.38 2.20 2.12 1.95 2,01 2.15 2.14 2.16 1.86 1.99 2.07 1,82 LZRPLOT Ver. 21n 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206005 22-12 2 ;4 3 p Accel No. 6 1/6 Octave ZPA: .84 gPk REQUIRED RESPONSE SPECTRA RRS File: Q1206OBE.RRS 22-12 9:17a 10.0 7.0 5.0 4.0 3.0 A 2.0 c c 1 r a t i 0 n .9 .7 .1 1 1 1k - 4... 4.. - A... t...... ~ ~ 7 I 1 z 00~ (g1s) .4 .3 .2 .1 I z, 0 I a IV zU 3U jV oU IU 6V AVUU Frequency (Hetz) LZRPLOT Ver. 2.1n 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 109 TEST RESPONSE SPECTRA Data File: Q1206005 22-12 2:43p REQUIRED RESPONSE SPECTRA Accel No. 6 1/6 Octave ZPA:.84 gPk RRS File. Q1206OBE.RRS 22-12 9:17a Required Response Spectra Freq Accel Fr-Accel Fre Accel LO 35 10-ý 1.05 50-0 .35 3.00 1.05 20.00 35 100.00 .35 Test Response Spectra Freq .5%Damp Z.0%Damp 3.0%Damp 5.0%Damp 7.0%Damp (h GPk GPk GPk GPk GPk lo1.09 .63 .52 .42 .35 112 L44 .86 .69 .56 .47 126 1.68 127 1.08 .80 .69 1.41 144 1.14 1.01 .80 .66 1.58 L70 124 103 .78 .65 L78 172 126 L06 .88 .76 2.00 2.44 1.46 116 .85 .75 2.24 2.88 1.68 1.36 1.08 .93 2.51 2.96 L71 L47 1.12 .98 2.82 2.94 191 165 1.34 1.14 316 3.72 2.09 166 1.19 .95 3.55 3.04 1.89 1.57 125 1.07 3.98 2.66 197 1.75 137 115 4.47 3.43 200 161 129 116 5.01 3.48 2.04 1.86 1.57 1.37 5.62 3.58 2.09 1.68 142 131 631 2-55 184 169 L40 1.22 7.08 3.21 2.07 L88 1.57 1.36 7.94 3.60 2.23 1.82 1-58 L45 8.91 537 233 194 L55 L44 10.00 3.25 2.61 2.22 175 146 11.22 4.86 2.31 177 1.44 129 12.59 2.02 134 1.17 109 .99 14.13 153 L04 101 .95 .89 15.85 3.04 1.71 144 120 L06 17.78 2.43 1.44 L23 101 .97 19.95 L74 116 1.14 1.08 L03 2239 2.66 155 136 113 1.07 25.12 156 1.06 107 1.06 1.01 2818 1.83 130 .18 L03 .94 31.62 L46 .98 .96 .92 .88 35.48 L47 1.15 108 .97 .90 39.81 L19 1.02 .99 .93 .89 44.67 132 110 103 .93 .89 50.12 L76 125 108 .97 .96 56.23 L06 L04 103 1.00 .98 63.10 1.18 .95 .96 .97 .97 70.79 149 135 122 1.04 .98 79.43 2.02 1.43 126 1.05 .99 89.1*3 1.30 113 109 1.05 1.03 100.00 160 130 121 L08 LOO LZRPLOT Ver. 2.ln 03.-22-2012

TEST RESPONSE SPECTRA Data File: Q1206005 22-12 2 :4 3p Accel No. 7 1/6 Octave ZPA: 1.25 gPk REQUIRED RESPONSE SPECTRA RRS File: Q1206OBE.RRS 22-12 9:17a 25.0 i.1

i 1 1 i AAA 1:1.

1 111. d-H-.-F+-i-}L i:!ii I i~i A c C e r ati 0 n Wgs) 10.0 7.0 5.0 3.0 2.0 1.0 .7 .5 t-d

  • I?"

I 4 4. -F I __4 2 50....

70.

1(. i- --5.- -0"y 1,. i : : i t 7 2 3 4: 5 6* 7 8 0 20 30 40 5 0 08 Z R0. G) Z t C- .3 .2 I)0 Frequency (Hertz) )o LZRPLOT Vet. 2. In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 111 TEST RESPONSE SPECTRA Data File. 01206005 22-12 2-43p REQUIRED RESPONSE SPECTRA Accel No. 7 1/6 Octave ZPA: L25 gPk RRS File: Q120O6BE.RRS 22-12 9.17a Required Response Spectra Freq Accel Freq Accel Freq Accel 1.00 .35 10.00 L05 50.00 .35 3600 1.05 20.00 .35 100.00 .35 Test Response Spectra Freq .5%Damp 7.0%Damp 3.0%Damp 5.0%Damp 7.0%Damp GPk GPk GPk GPk GPk .53 .44 .41 .36 .32 1.12 1.67 LI .95 .73 .59 L26 L75 1.28 1.10 .86 .73 1.41 1.63 .97 .86 .76 .68 158 1.88 1.19 1.02 .79 .66 1.78 1-53 1.08 .90 .75 .66 2.00 2.14 1.35 1.17 .98 .85 2.24 2.12 1.45 126 1.15 L02 2.51 1.43 1.23 1.13 .99 .90 2.82 3.31 L96 L65 131 L12 3.16 411 2.32 1.92 1.48 1.22 3.55 3.08 1.75 L48 1.36 L22 3.98 3.12 2.10 1.84 1.49 1.26 4.47 2.80 2.44 2.08 L60 1.34 5.01 3.69 2.25 2.03 L73 1.50 5.62 4.92 2.31 2.01 1.73 1.51 6.31 4.30 3.02 2.65 221 1.91 7.08 4.42 2.4 2.52 2.12 1.94 7.94 5.93 4.16 3.52 2.73 2.26 &91 6.16 3.40 3.09 2.49 2.09 10.00 5.94 3.89 3.43 2.96 2.58 1122 6.85 4.07 3.95 3.61 3.22 12.59 13.94 7.00 5.59 4.02 320 14.13 9.38 5.51 4.85 3.87 3.31 15.85 7.06 433 4.07 3.60 317 17.78 6.36 4.01 3.52 2.92 2.55 19.95 5.56 3.30 2.87 2.43 2.14 22.39 4.68 3.64 3.21 2.66 2.31 25.12 3.57 2.52 2.25 1.95 L77 2818 5.52 334 2.95 2.60 2.33 31.62 10.77 5.52 4.42 3.40 2.91 35.48 9.58 5.59 4.62 3.54 2.91 39.81 4.18 3.16 2.81 2.34 2.09 44.67 3.09 2.12 L97 1.79 L68 50.12 2.89 2.14 L99 1.85 1.77 56.23 2.38 1.94 L76 [61 1.60 63.10 2.29 1.83 1.69 L55 1.52 70.79 1.98 1-54 1.50 L48 147 79.43 2.33 1.80 L71 1.58 1.51 89.13 2.90 2.05 L85 1.66 1.51 100.00 3.56 228 2.02 1.71 1.55 LZRPLOT Ver. 2.1n 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206005 22-12 2:4 3p Accel No. 8 1/6 Octave ZPA: 1.47 gPk REQUIRED RESPONSE SPECTRA RRS Mile: QI206OBE.RRS 22-12 9:17a 25.0 ~ 4t~t - 77 A c C e a t i 0 n 10.0 7.0 5.0 3.0 2.0 1.0 .I--. ,--r---7 ~~~ .i. -- 17 z7..

ij
:

- ~ ~ ~ ~. L i t "A....... .l.... (D - z (g's) .7 .5 .3 .2 .1 oI 2 .5 0 1 5 iJv .zu, 3V 4i4V ZlIu cu Iu ou lV) Frequency (He=) LZRPLOT Ver. 2. In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 113 TEST RESPONSE SPECTRA Data File-Q1206005 22-12 2-43p Accel No. 8 1/6 Octave ZPA: L47 gPk REQUIRED RESPONSE SPECTRA RRS File: Q12O6OBE.RRS 22-12 9:17a Required Response Spectra Fr Accel Fr L.35 10 3.00 L05 20.00 Test Response Spectra Freq 112 126 141 158 1.78 2.00 2.24 2.51 2.82 3.16 3.55 3.98 4.47 5.01 5.62 6.31 7.08 7.94 8.91 10.00 1122 12.59 14.13 15.85 17.78 19.95 22.39 25.12 28.18 31.62 35.48 39.81 44.67 50.12 56.23 63.10 70V9 79.43 89.13 100.00 .5%Damp GPk .85 1.94 1.05 119 .92 1.94 1.67 325 2.45 3.42 4.44 5.95 431 4.25 4.94 5.57 13.85 23.91 24.70 lO.81 8.45 3.91 2.83 2.86 2.62 3.78 2.46 2.65 237 2.17 1.95 2.09 1.69 186 1.86 2.77 2.57 3.01 2-36 2.54 2.54 Accel 105 .35 2.0%Damp GPk .66 103 .79 .74 .78 1.32 118 174 2.13 2.30 2.42 2.99 2.54 2.49 3.76 329 8.13 1188 13.47 6.75 4.71 2.87 2.-3 2.11 2.02 2.56 2.04 2.17 197 170 1.74 178 1.55 1.54 176 2.15 199 2.13 2.00 2.07 L95 100.00 Accel .35 .35 3.0%Damp GPk .56 .86 .70 .68 .72 1.09 101 138 180 1-96 L97 2.39 2.22 2.36 3.31 129 6.60 929 1102 633 3.99 2.60 237 2.06 1.91 227 197 195 1.94 164 L72 1.72 153 154 173 198 191 2.02 189 1.96 183 5.0%Damp GPk .44 .67 .57 .58 .63 .84 .80 1.05 138 151 147 181 192 2.06 2.75 3.03 5.35 7.53 7.98 5.23 3.40 2.49 2.31 2.04 1.86 2.07 184 1.83 1.86 1.59 1.65 163 1.50 1.55 1.68 183 181 1.93 182 189 1.76 7.0%Damp GPk -37 .56 .50 .52 .57 .70 .71 .94 .11 130 120 152 171 180 2.41 2.85 4.50 6.26 6.24 4.28 3.07 2.46 2.26 2.03 1.87 198 1.79 176 1.79 156 159 157 1.48 1.54 165 L76 172 184 1.76 181 1.71 LZRPLOT Ver. 2.1n 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206005 22-12 2:43p Accel No. 9 1/6 Octave ZPA: 1.01 gPk REQUIRED RESPONSE SPECTRA RRS File: Q12060BE.RRS 22-12 9:17a 25.0 A __~ ~ I~ -'-1-i--f-LL~.I HH F" I~v-~ I-10.0 7.0 5.0 A C e ra I 0 11 3.0 2.0 1.0 ofL

  • ~ ~~

~ mo C) (g's) .7 .5 .3 .2 .1 I 2 3 4 5 6 7 8 10 Frequency (Hertz) 20 30 40 50 60 70 80 100 LZRPLOT Ver. 2.In 03-22-2012

Report No, EGS-TR-HC589-01 Appendix II, Page No. 115 TEST RESPONSE SPECTRA Data File: Q1206005 22-12 2.43p REQUIRED RESPONSE SPECTRA Accel No. 9 1/6 Octave ZPA 1.01 gPk RRS File: Q1206OBERRS 22-12 9:17a Required Response Spectra Fre* Accel Fr Accel Freq Accel .35 10.0 1.05 50.00 .35 3.00 1.05 20.00 .35 100.00 .35 Test Response Spectra Freq .5%Damp 2.0%Damp 3.0%Damp 5.0%Damp 7.0%Damp 1.0* GPk GPk GPk GPk GPk .53 .44 .4 36 .32 112 159 110 .95 .73 .59 126 168 1.25 L06 .83 .70 1.41 1.55 .93 .82 .73 .66 158 1.80 L13 .97 .76 .63 1.78 L49 106 .89 .72 .64 2-00 2.04 1.31 [14 .95 .82 2.24 2.03 1,39 1.26 1.13 .99 2.51 L41 1.20 1.10 .97 .88 2.82 3.09 1.7 1.59 L26 1.07 3.16 4.05 2.26 1.87 1.43 1.18 3.55 2.84 1.61 148 1.32 1.18 3.98 2.94 2.02 178 L44 1.21 4.47 2.79 2.39 2.03 [56 129 5.01 3.33 2.11 1.96 1.66 1.45 5.62 4.38 2.09 1.84 1.59 1.39 6.31 3.81 2.71 2-44 2.04 L76 7.08 4.40 2.71 2.36 L94 1.71 7.94 4.89 3.60 3.09 2.42 2.01 8.91 5A1 3.01 2.74 2.20 1.84 10.00 5.09 3.38 2.79 2.40 2.08 11.22 5.46 3.19 3.09 2.83 2.52 12.59 10.52 5.34 427 3.04 2.40 14.13 6.65 4.14 3.64 2.95 2.46 15.85 418 2.98 2.85 2.59 234 17.78 3.58 2.50 2.25 1.96 1.77 19.95 166 1.42 134 126 1.26 2239 1.59 1.32 1.26 L15 1.13 25.12 2.64 1.53 1.41 133 127 2&18 2.09 1.70 1.54 138 L28 31.62 314 1.97 L68 1.50 1.45 35A8 4.90 3.07 2.59 2.08 1.3 39.81 3.27 2.71 2.48 2.11 1.85 44.67 2.61 1.85 L68 L68 1.64 5012 3.06 2.22 L95 1.77 1.67 56.23 2.29 1.67 1.58 1.50 1.43 6310 2.97 1.9 L65 L41 1.29 70.79 2.66 L72 1.60 L46 L33 79.43 3.51 2.42 221 1.84 1.55 89.13 3.28 2.31 2.05 1.77 1.63 100.00 2.87 2.05 L96 L76 1.60 LZRPLOT Ver. 2.1n 03-22-2012

TEST RESPONSE SPECTRA Data Pile: Q1206005 22-12 2:43p Accel No. 10 1/6 Octave ZPA: 1.69 gPk REQUIRED RESPONSE SPECTRA RRS File: Q12060BE.RRS 22-12 9:17a 25.0 10.0 7.0 5.0 A c c le 1 e r a.t I10 n (91s) 3.0 2.0 1.0 .7 .i t" 11111. - -I-F---....... CID =3 Z OL - zrG)~ ,5 .2 .1 2 3 4 5 6 7 8 10 FRequency (Hertz) 20 30 40 50 60 70 80 100 LZRPLOT Vet. 2. In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix I1, Page No. 117 TEST RESPONSE SPECTRA Data File: Q1206005 22-12 243p REQUIRED RESPONSE SPECTRA Accel No. 10 1/6 Octave ZPA: 1.69 gPk RRS File-Q1206OBERRS 22-12 9.17a Required Response Spectra Fr ccl Freq Accel Freq Accel .35 10.00 1.05 00.00 .35 3.00 L05 20.00 .35 100.00 .35 Test Response Spectra Freq .5%Damp 2.0%Damp 3.0%Damp 5.0%Damp 7.0%Damp (hzh GPk GPk GPk GPk GPk .85 .66 .57 .45 .37 L12 1.93 1.02 .86 .67 .57 1.26 Los .79 .71 .56 .49 1.41 1.21 .73 .66 .57 -51 1.58 .90 .79 .73 .64 .58 1.78 1.94 1.32 L09 .84 .70 2.00 1.66 1.17 1.006 .79 .69 2.24 3.28 L75 1.36 1.04 .88 2.51 2.44 2.12 1.81 1.38 1.12 2.82 327 2.19 1.87 L44 1.27 3.16 429 2.33 1.89 1.41 L14 3.55 5.79 2.88 2.29 1.73 L44 3.98 3.99 232 2.09 1.81 1.60 4.47 4.06 231 2.14 1.88 L66 5.01 4.46 3.45 3.02 2.50 2.13 5.62 4.89 290 2.67 2.45 2.32 631 11.59 6.76 5.50 4.45 3.74 7.08 19.31 9.67 7.49 5.92 4.93 7.94 19.07 10.25 &41 6.10 4.79 8.91 8.16 5.13 4.77 3.95 3.25 10.00 5.98 3.49 3.00 2.49 2.23 1122 2.88 2.14 2.03 L92 L90 12.59 224 1.88 1.86 1.1 1.76 14.13 2.21 2.00 191 1.79 L72 15.85 2.53 L91 L80 L70 L64 17.78 3.06 1L88 1.69 1.71 1.70 19.95 3.19 2.11 1.92 1.80 L73 2239 3.53 Z10 1.93 L70 1.55 25.12 3.04 L66 L54 1.39 1.35 28.18 2.65 1.72 1.55 1.47 1.41 3162 2.14 1.69 L66 1.60 1L54 35.48 2.52 1.81 L72 [62 1.53 39.81 2.24 1.76 1.74 L66 1.63 44.67 3.21 2.44 2.28 2.10 2.00 50.12 161 2.42 2.41 2.35 2.29 56.23 2.93 279 2.81 2.75 2.65 63.10 4.74 3.54 3.28 3.01 2.85 70.79 7.22 425 3.74 2.99 2-77 79.43 6.67 4.58 4.16 351 3.16 89.13 10.54 6.16 4.80 3.58 326 100.00 739 4.78 4.24 3.61 3.24 LZRPLOT Ver. 2.1n 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206005 22-12 2 :43 p Accel No. 11 1/6 Octave ZPA: 1.15 gPk REQUIRED RESPONSE SPECTRA RRS le: Q1206OBE.RRS 22-12 9:17a 10.0 7.0 5.0 4.0 3.0 2.0 .9 .7 1I I -.1 " I III ! I ! i A c c e 1 e r at 0 n .i ]j vv 04_ I -mG) zz Po (g's) .5 .4 .3 .2 .1 2 3 5 6 7 8 10 Frequency (Hertz) 20 30 40 50 60 70 80 100 LZRPLOT Ver. 2. In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 119 TEST RESPONSE SPECTRA Data File: 01206005 22-12 2.4 3p REQUIRED RESPONSE SPECTRA Accel No. 11 1/6 Octave ZPA. 115 gPk RRS File: Q1206OBE.RRS 22-12 917a Required Response Spectra Fr~ Accel Freq Acc1 Freq Accel .35 10.06 1.05 .35 3.00 1.05 20.00 35 100.00 .35 Test Response Spectra Freq .5%Damp 2.0%Damp 3.0%Damp 5.0%Damp 7.0%Damp S GPk GPk GPk GPk GPk mL06 60 .50 39 .33 1.12 1.39 .83 .67 .54 .45 126 L56 1.18 1.01 .76 .66 1.41 1.27 1.04 .92 .75 .62 1.58 1.69 L20 99 .75 .63 1.78 163 1.9 L.01 81 .70 2.00 2.31 1.38 L1l .80 .73 224 2.61 1.56 1.27 1.00 .86 2.51 2.86 1.57 135 L09 .96 2.82 2.71 1.83 1.58 1.29 1.09 3.16 3.63 1.99 L58 1.13 .92 3.55 2.88 1.68 1.41 1.20 1.03 3.98 2.53 181 L63 1.29 1.10 4.47 3.29 L92 L55 118 1.05 5.01 3.39 183 1.68 1.42 1.23 5.62 3.45 1.99 1.60 127 1.17 631 2.65 1.88 1.73 1A4 1.21 7.08 3.40 2.05 1.80 L48 1.28 7.94 3.31 1.97 1.68 1.35 1.19 8.91 5-14 2.33 1.89 1.50 1.28 10.00 3.19 2.47 2.10 L65 1.38 11.22 4.65 2.19 1.69 1.29 117 12.59 200 131 1.12 .98 .89 1413 L44 .98 .91 86 82 15.85 2.58 1.43 1.27 1.08 .96 17.78 2.00 1.29 1.16 LOI .96 19.95 L46 1.31 127 1.18 1.10 22.39 2.34 1.54 1.43 132 1.21 25.12 2.70 1.62 1.45 1.20 L08 28.18 2.59 1.92 174 1.45 1.24 31.62 1.90 1.44 1.34 L18 1.4 35.48 L70 1.30 L26 1.18 1.12 39.81 1.50 1.35 1.23 1.07 L04 44.67 2.02 1.57 1.46 1.30 1.18 50.12 L96 L67 1.53 1.33 126 56.23 2.76 2.38 2.19 1.87 L68 63.10 3.14 2.62 2.35 L97 L72 70.79 2.83 2.40 2.34 2.22 2.09 79.43 5.09 4.17 3.53 -3.03 2.66 89.13 5.68 5.07 4.57 3.77 3.20 100.00 4.44 3.46 3.21 2.71 2.42 LZRPLOT Ver. 2.n 03-22-2012

TEST RESPONSE SPECTRA Data Pile: Q1206006 22-12 2:49p Accel No. 1 1/ 6 Octave ZPA. REQUIRED RESPONSE SPECTRA .70 gPk RRS File: Q1206SSF.RRS 22-12 9:19a A c C e1 C r a t 0 n (g's) 10.0 7.0 5.0 4.0 3.0 2.0 .9 .7 .5 .4 .3 .2 .1 A I ./V* i ! I 1 Z f I 6<_ ~~~~~~~.....,.*._. t t N i l 0.0 A ! °. 2 3 4 5 6 7 8 10 20 30 40 50 60 70 80 100 Fiequency (Hertz) LZRPLOT Ver. 2. In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 121 TEST RESPONSE SPECTRA Data File: 01206006 22-12 2:49p REQUIRED RESPONSE SPECTRA Accel No. 1 1/6 Octave ZPA..70 gPk RRS File: QI206SSE.RRS 22-12 91"9a Required Response Spectra Froq Accel Fr Accel Fre Accel 100 I00 L50 50.0 .50 3600 1.50 20.00 .50 100.00 .50 Test Response Spectra Freq .5%Damp 2.0%Damp 3.0%Damp 5.0%Damp 7.0%Damp GPk GPk GPk GPk GPk .74 .62 .57 .50 .45 1.12 2.26 L52 133 1.01 .82 126 2.39 L77 1.52 1.18 L00 L41 2.30 1.36 1.20 1.06 .95 158 2.56 1.60 1.37 1.08 .89 L78 2.03 L47 123 .99 .87 2.00 2.88 1.83 1.58 131 15 2.24 2.78 L91 1,71 1.54 1.35 2.51 L80 L60 1.48 1.31 121 2.82 4.25 2.51 2.10 1.67 L46 316 5.25 2.96 2.45 L88 1.55 3.55 3.77 116 1.93 1.75 1.56 3.98 4.08 2.72 2.40 1.95 1.64 4.47 3.50 3.03 2.58 1.98 L65 5.01 4.23 2.71 2.44 2.01 172 5.62 5.53 2.69 2.21 1.91 1.71 631 5.06 3.44 3.04 2.50 2.13 7.08 4.95 2.93 253 2-08 1.86 7.94 5.50 3.90 3.28 2.53 2-08 &91 5.08 2.69 2.41 t97 1.72 10.00 3.99 174 2.36 1.87 1.59 1L22 3.85 224 1.99 L66 1.42 12.59 5.72 2.66 2.10 L70 149 14.13 2.60 1.66 L44 L28 117 15.85 2.18 1.37 1.33 1.27 1.18 17.78 3.21 2.27 L92 1.54 133 19.95 2.43 1.45 131 L16 1.08 2239 L88 1.28 1.15 .00 .92 25.12 1.21 1.15 105 .93 .88 28.18 1.16 .98 .96 92 .89 31.62 1.15 .97 .91 .85 .83 35.48 103 .89 .86 .82 .79 39.81 .97 .84 .80 .77 .74 44.67 L12 .85 .78 .73 .72 5012 .90 .78 .75 .74 .73 56.23 .93 .77 .75 .75 .74 63.10 .88 .82 .80 .77 .75 70.79 S6 .78 .77 .75 .74 79.43 1.01 .80 .77 .75 .74 89.13 .90 ,81 .79 .77 .76 100.00 .94 .81 .80 .78 .7.7 LZRPLOT Ver. 2-1n 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206006 22-12 2:49p. Accel No. 2 1/6 Octave ZPA: .87 gPk

  • REQUIRED RESPONSE SPECTRA RRS File: Q1206SSE.RRS 22-12 9:19a A

c c 1 e r 0n (S's) 10.0 7.0 5.0 4.0 3.0 2.0 .9 .7 .5 .4 .3 .2 .I I I./ A I.1 I k. I.. I..1.. I. a I I t I F, I I I Il L i I-I -%--L I : I I V Il* >x I .~ 2.. a CD Z mc cou F* )o Frequency (Hertz) LZRPLOT Vet. 2. In 03-22-2012

Report No. EGS-TR-HC589.01 Appendix II, Page No. 123 TEST RESPONSE SPECTRA Data File: Q1206006 22-12 2:49 p Accel No. 2 1/6 Octave ZPA:.87 gPk REQUIRED RESPONSE SPECTRA RRS File: Q1206SSE.RRS 22-12 9:19a Required Response Spectra Freq Accel Froq 1.00 .50 10.00 3.00 1.50 20.00 Test Response Spectra Accel 1.50 .50 100.00 Accel .50 .50 Freq L12 1.26 L41 1.58 1.78 2.00 2.24 2-51 2.82 3.16 3.55 3.98 4.47 5.01 5.62 631 7.08 7.94 8.91 10.00 1122 12.59 14.13 15.85 17.78 19.95 22.39 2512 28.18 31.62 35.48 39.81 44.67 50.12 5623 63.10 70.79 79.43 89.13 100.00 .5%Damp GPk 123 2.83 1.63 1.76 1.31 2.74 2.37 4.70 3.28 4.19 5.37 7.41 4.66 428 4.13 3.67 6.62 6.60 4.97 4.73 4.38 2.60 2.52 2.98 4.98 7.97 5.70 3159 1.85 162 1.42 1.39 1.31 1.18 L18 1.05 1.07 .96 1.05 .94 .94 2.0%Damp GPk .94 1.44 1.18 1.06 1.07 1.84 1.69 2.48 2.92 2.72 2.91 3.74 2.70 2.67 3.38 2.26 3.78 3.71 326 2.87 2.35 1.75 1.51 2.12 2.77 4.34 3.58 2.19 1.66 134 1.28 1.09 1.13 .00 .98 .91 1.00 .94 .93 .90 .92 3,0%Damp GPk .81 £21 1.00 .91 1.51 L45 1.94 2.55 2.28 2.32 2.82 2.29 230 2.89 2.03 3.07 3.02 287 2.57 1.94 1.54 1.40 1.83 2.53 3.67 318 1.89 1.62 135 1.27 1.02 112 101 .95 m8 .97 .93 .93 .89 .91 5.0%Damp OPk .65 .95 .79 .78 .87 1.15 1.16 1.46 1.99 .84 .67 2.07 L96 £95 2-32 £77 2.24 2.27 228 2.14 1.58 138 1.29 1.67 2.24 2.95 2-56 £70 1.51 131 125 1.05 1.10 1.01 .93 S6 .93 .93 .92 .88 .90 7.0%Damp GPk .55 .79 .69 .69 .79 .95 .98 1.23 1.61 1.63 1.38 1.71 1.71 1.71 1.97 1.65 178 1.85 1.89 1.84 1.41 1.29 1.27 1.58 2.00 2.54 115 1.60 1.41 128 122 1.07 1.08 1.00 .93 .86 .91 .92 .91 .87 .89 LZRPLOT Ver. 21n 03-22-2012

TEST RESPONSE SPECTRA DataFile: Q1206006 22-12 2 :49p Accel No. 3 1/ 6 Octave ZPAk 1.05 gPk REQUIRED RESPONSE SPECTRA RRS File: Q1206SSE.RRS 22-12 9:19a 10.0 7.0 5.0 4.0 3.0 2.0 .9 .7 i i

I A

.1 A C C r a t i 0 u ,.,l

  • .°............",..

M F.. .I 7 23 4 5678 10 20 30 40 50 60 70 80 1C m OZ( 0 nt (g*s) .5 .4 .3 .2 .1 ]0 Frequency (Hertz) LZRPLOT Ver. 2. In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 125 TEST RESPONSE SPECTRA Data File: Q1206006 22-12 2.49p REQUIRED RESPONSE SPECTRA Accel No. 3 1/6 Octave ZPk-1.05 gPk RRS File: Q1206SSE.RRS 22-12 9.19a Required Response Spectra Freq Accel Freq Accel Freq Accel .50 10.00 1.50 50.00 m50 3.00 1.50 20.00 .50 100.00 .50 Test Response Spcctra Freq .5%Damp 2.0%Damp 3.0%Damp 5.0%Damp 7.0%Damp z GPk GPk GPk GPk GPk .L43 .82 .68 54 .46 1.12 1.88 1.12 .91 .73 .61 1.26 2.17 1.65 L40 1.6 .89 1.41 1.74 1.41 126 1.02 .85 1.58 2.28 1.62 1L34 1.01 .84 1.78 2.28 1.66 1.41 1.18 L02 2.00 3.26 1.93 153 112 1.01 2.24 3.73 2.24 1.86 L46 1.26 2.51 4.02 Z25 L94 1.49 131 2.82 4.05 2.66 2.29 1.85 1.56 3.16 5.19 2.88 2.29 1.64 L30 3.55 4,27 2.55 2.22 1.78 L47 3.98 3.75 2.71 2.41 1.90 L57 4.47 4.76 2.73 220 1.76 L58 5.01 5.00 2.81 2.59 2.21 1.93 5.62 5.13 2.96 2.40 2.00 L85 6.31 3.75 2.77 2.55 2.14 L85 7.08 5.77 3.51 3.17 2.63 2.27 7.94 6.45 3.62 2.96 2.44 2-22 8.91 8.16 3.66 2.97 2.36 Z09 10.00 4.15 3.19 2.65 2.06 L91 1M22 2.81 2.05 1.88 173 1.67 12.59 1.84 1.24 1.22 1.26 1.31 14.13 L93 1.30 1.31 134 L35 15.85 2.25 1.53 L40 134 L.35 17.78 2.36 L59 1.51 1.39 L34 19.95 2.19 L68 1.59 1.44 1.39 2239 3.04 2.14 1.81 1.50 L40 25.12 3.30 2.05 1.74 1.39 1.27 2818 2.47 1.94 1.73 1.45 137 3162 2.16 L57 L44 1.37 1.32 35.48 183 144 135 1.29 1.24 39.81 L48 128 125 121 L18 44.67 135 1.25 1.24 L21 1.19 50.12 128 L22 1.20 1.16 1.13 5623 1.26 L07 1.07 1.07 1.06 63.10 128 116 1.14 1.12 LIO 70.79 L17 1.12 111 1.10 .10 79.43 1.33 119 1.16 1.14 L12 89.13 1.21 L15 1.14 L13 1.11 100.00 1-34 113 1.11 1.09 L08 LZRPLOT Ver. Zln 03-22-2012

TEST RESPONSE SPECTRA Data Ble: Q1206006 22-12 2 :4 9p Accel No. 4 1/6 Octave ZPA: 1.88 gPk REQUIRED RESPONSE SPECTRA RRS File: Q1206SSE.RRS 22-12 9:19a 25.0 10.0 7.0 5.0 A c e 1 e r a t i 0 In 3.0 2.0 1.0 A I ,JJ - -t.

  • i t,.4 1

3 4 78 020 30 40 50 60 7080 1C m Z x 900 (gs) .7 .5 .3 .2 .1 I0 Frequency (Hertz) LZRPLOT Ver. 2.1n 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 127 TEST RESPONSE SPECTRA Data File:. Q1206006 22-12 2.49p Accel No. 4 1/6 Octave ZPA* 188 gPk Required Response Spectra REQUIRED RESPONSE SPECTRA RRS File: Q1206SSERRS 22-12 9:19a Fr Accel .50 3.00 1.50 Freq Accel 10.00 1.50 20.00 .50 100.0 Accel .50 .50 Test Response Spectra Freq 112 1.26 L41 L58 1.78 200 224 251 2.82 3.16 355 3.98 4.47 5.01 5.62 631 7.08 7.94 8.91 10.00 1122 12.59 14.13 15.85 17.78 19.95 22-39 25.12 28.18 3162 35.48 39,81 44.67 50.12 56.23 63-10 70.79 79.43 89.13 100.00 .5%Damp GPk .83 2.20 2.48 2.57 2.80 2.21 2.94 3.00 2.08 4.55 5.86 422 4.99 3.67 5.07 6.82 6.19 7-16 8.94 &45 7.98 1031 21.99 13.62 8.89 7.11 3.94 3.48 4.21 3.08 3.02 3.35 3.15 4.78 3.81 310 3.78 4.74 6.76 5.74 3.81 2.0%Damp GPk .69 1.54 1.84 152 L67 1.53 1.82 2.01 L73 2.69 3.29 2.53 3.05 3.33 3.28 3.22 4.39 4-15 5.94 4.87 5.26 7.02 10.30 &74 5.70 5.00 2.94 2.72 3.02 2.39 2.25 2.52 2.63 4.23 3.61 2.90 3.10 3.99 5.15 3.92 3.66 3.0%Damp GPk .63 1.34 158 1-30 144 130 1.59 1.78 1.57 2.26 2.72 2-18 2.65 2.87 3.06 2.96 3.95 355 4.99 423 4.75 6.05 &03 7.10 5.43 4.4.1 2.70 2.52 2.72 2.18 2.15 234 2.42 3.74 3.41 2.85 2.92 3.59 4.47 3.70 359 5.0%Damp GPk .56 L02 125 113 114 105 1L33 1.60 136 1.83 2.09 198 2.14 2.27 2.61 2.60 3.28 3.18 3.82 3.45 4.14 5.06 5.98 5.53 4.85 3.67 254 2.45 2.38 2.01 2.03 2.17 213 3.08 3.03 2.77 2.81 3.08 3.77 3.55 3.44 7.0%Damp GPk .50 m2 L07 L01 .94 .93 117 L41 125 1-57 1.73 1.77 182 1.92 2.26 2-29 2.81 2.96 3.18 3.00 3.65 4.52 4.82 4.54 4-30 322 2.47 238 2.18 1,95 L98 2.05 2.11 2.75 2.73 2.69 2.75 2.87 3.52 3.41 332 LZRPLOT Ver. 2.lin 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206006 22-12 2 :49 p Accel No. 5 1/ 6 Octave ZPA: 2.48 gPk REQUIRED RESPONSE SPECTRA RRS File: Q1206SSE.RRS 22-12 9:19a A C C e 1 e ra t i (g's) 50.0 30.0 20b0 10.0 7.0 5.0 3.0 2.0 1.0 .7 .5 Tf T I I oI IVIM >1 u@) I .3 .2 .1 I 2 3 4 5 6 7 8 10 Frequency (Hertz) 20 30 40 50 60 70 80 100 LZRPLOT Ver. 2.1n 03-22-2012

Report No. EGS-TR-HC589.01 Appendix 11, Page No. 129 TEST RESPONSE SPECTRA Data Fil: 01206006 22-12 2.49p Acce! No. 5 1/6 Octave ZPA: 2.48 gPk Required Response Spectra REQUIRED RESPONSE SPECTRA RRS File: Q1206SSE.RRS 22-12 919a Freq 1.00 3.00 Accel .50 1.50 Fr 20.00 Accel 1.50 -50 Freq 50.00 100.00 Accel .50 .50 Test Response Spectra Freq 1.12 1.26 1.41 1.58 L78 200 224 251 2.82 3.16 355 3.98 4.47 5.01 5.62 6.31 7.08 7.94 &91 10.00 11.22 12.59 14.13 15.85 17.78 19.95 2239 25.12 28.18 31.62 35.48 39.81 44.67 50.12 5623 63.10 70.79 79.43 89.13 100.00 .5%Damp GPk 137 2.98 169 1.97 1.53 2.96 2-56 5.25 3.97 5.86 7.32 10.12 7.23 7.41 9.87 11.02 30.07 47.08 28.73 14.36 9.09 5.90 4.94 4.67 5.23 636 5.63 532 5.44 6.62 5.08 4.26 4.36 4.29 426 5.78 4.79 4.06 4.63 4.66 3.62 2.0%Damp GPk 1.03 1,54 1.21 120 1.15 2-03 1.91 2.77 3.56 3.88 4.04 5.10 4.17 4.57 7.14 7.46 17.76 23.76 18.71 9.15 6.23 4.34 3.89 4.10 4.09 531 4.09 3.78 3.82 4.34 3.81 331 3.20 3.52 4.05 5.14 3.88 4.10 4.02 3.53 3.04 3.0%Damp GPk .87 1.30 107 L04 L09 1.69 166 219 3.09 3.29 332 4.07 3.88 4.18 6.36 6.65 14.98 18.70 15.63 8.63 5.48 4.12 3.76 3.87 3.84 4.71 3.89 3.54 3.56 4.03 3.61 315 298 336 3.89 4.74 3.73 3.97 3.87 320 3.02 5.0%Damp GPk .69 L03 .85 .87 .98 L32 1.35 1.71 2.40 2.53 2-52 297 3.37 3.69 5.12 5.81 11.38 13.42 11.52 7.12 4.73 3.95 3.61 3.74 3.73 3.96 3.67 3.34 3.47 3.66 3.43 2-96 2.89 3.12 3.58 4.22 3.60 3.79 3.62 3.10 29% 7.0%Damp GPk .60 .87 .74 .79 .90 L10 1.16 L45 L94 2.19 208 2.47 3.01 3.35 4.42 5.52 9,17 10.86 9.47 6.28 4.41 3.88 3.57 3.65 3.63 3.70 3.52 3.31 3.34 3.46 3.32 2.87 2,82 3.06 339 3.90 3.54 3.64 3.47 3.05 2-91 LZRPLOT Ver. 21n 03-22-2012

TEST RESPONSE SPECTRA Data Pile: Q1206006 22-12 2:49p Accel No. 6 1/6 Octave ZPA: 1.27 gPk REQUIRED RESPONSE SPECTRA RRS File: Q1206SSE.RRS 22-12 9:19a 10.0 7.0 5.0 4.0 3.0 2.0 .9 .7 I 1.1 I ý 1ý ý, A c e1 r a t i 0 n [... i 2 3 4 7 8 10 20 30 40 50 60 70 80 I1 PCD Z~ 3: (g's) .5 .4 .3 .2 .1 1 DO T- )D Frequency (Hertz) LZRPLOT Ver. 2. In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 131 TEST RESPONSE SPECTRA Data File: Q1206006 22-12 2 49 p REQUIRED RESPONSE SPECTRA Aceel No. 6 1/6 Octave ZPA: 1.27 gPk RRS File: Q1206SSE.RRS 22-12 9:19a Required Response Spectra Fre Accel Fr Accel Freq Accel .50 10.0 [50 50.00 .50 3.00 1.50 20.00 .50 100.00 .50 Test Response Spectra Freq 5%Damp 2.0%Damp 3.0%Damp 5.0%Damp 7.0%Damp (hz) GPk GPk GPk GPk GPk 1.00 1.62 .93 .76 .60 .51 1.12 2.07 1.24 1.01 .80 .67 126 2.38 181 L53 1.15 .97 1.41 1.90 1.54 1.37 111 .92 1.58 2.47 177 L46 1.11 .92 L78 2.49 1.81 1.57 133 1.14 2-00 3.49 2.06 L64 121 1.13 224 4.07 2.45 2.02 1.61 1.39 2.51 4.24 2.45 211 1.59 1.41 2.82 4.36 2.86 2.46 1.99 L68 3.16 5.58 3.12 2.48 1.78 1.41 3.55 4.55 2.84 2.37 1.90 158 3.98 4.02 2.94 2.61 2.04 1.69 4.47 5.20 2.97 2.39 1.97 L78 5.01 5.38 3.17 2.91 2.48 2.16 5.62 5.51 321 2.61 2.24 2.07 6.31 4.06 2.99 2.77 2.32 2.08 7.08 621 3.82 3.45 2.87 2.47 7.94 711 4.01 3.26 2.82 2.57 891 9.24 4.09 332 2.62 2.44 10.00 4.92 3.73 3.07 237 2.19 11.22 3.57 2.37 2.16 1.93 1.89 12.59 2.80 170 1-57 1.59 L61 14.13 2.40 1.64 1.64 L65 L63 15.85 3.47 2.24 L92 1.63 L46 17.78 3.6 2.17 1.99 L77 L63 19.95 2.54 Z12 2.00 183 1.70 2239 3.49 2.31 2.02 L62 1.59 25.12 2.77 1.95 1.77 1.56 1.46 28.18 2.47 1.68 162 151 L45 31.62 2.40 1.58 137 135 L35 35.48 2.09 81 1.70 1.57 L47 39.81 2.20 188 L81 1.69 L60 44.67 4.00 2.96 2.57 2.14 L80 50.12 3.61 2.90 2.60 2.26 2.01 56.23 2.28 2.11 2.05 1.91 L77 6310 3.00 Z52 232 2.07 L92 70.79 4.36 3.64 324 2.70 2.33 79A3 632 4.06 3.40 2.71 2.30 89.13 315 2.98 2.76 2.39 2.11 100.00 4.04 3.15 2.93 2.53 2.24 LZRPLOT Vet. 2.1n 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206006 22-12 2:49p Accel No. 7 1/6 Octave ZPA: 1.91 gPk REQUIRED RESPONSE SPECTRA RRS Pile: Q1206SSE.RRS 22-12 9:19a 25.0 10.0 7.0 5.0 A c c 3.0 e e 2.0 r a ti 0 n 1.0 (g's) .7 .5 I.- t -1. -141.- fT i i i I g I I 4.~----4-- '1. - Il "I. I'-~~---' V.L j.L1 I ~1 ~ I-I\\

  • I i I I.*

I i I I I i_4% I I I I I I I I.ý I, I I. rz.- I_% 1IN I lI/ /V IN xI. i I I .-10T 1 x I -.l A. '7 -" _-7 .........7 "-7""I. ,,...........i... I4L 20 3 .0.5...7080. 23 4 5 6 7 8 10 20 30 40 50 60 70 80 1* X. m .3 .2 .1 I 10 Frequency (Her-) LZRPLOT Ver. 2. In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 133 TEST RESPONSE SPECTRA Data File: Q1206006 22-12 2-49p Accel No. 7 1/6 Octave ZPA 1.91 gPk Required Response Spectra FFr Accel Fre Accel Freq Accel .50 10.00 L50 50.00 .50 3.00 1.50 20.00 .50 100.00 .50 REQUIRED RESPONSE SPECTRA RRS File: Q1206SSE.RRS 22-12 9:19a Test Response Spectra Freq .5%Damp (l*z) GPk 1.00 .74 112 2.33 1.26 2.46 1.41 2.37 158 2.66 1.78 2.15 2.00 3.05 2.24 2.96 2.51 2.01 282 4.58 3.16 5.71 3.55 4.21 3.98 4.69 4.47 3.69 5.01 512 5.62 7.06 6.31 6.36 7.08 6.23 7.94 9.06 8.91 8.65 10.00 8.20 11.22 10.52 12.59 22.53 14.13 14.17 1585 9.14 17.78 8.18 19.95 7.15 22.39 5.89 2512 6.25 28.18 8.43 3162 15.80 35.48 12.07 39.81 5.58 44.67 4.41 50.12 3.61 56.23 3.45 6310 329 70.79 2.84 79.43 3.17 89.13 5.56 100.00 5.09 2.0%Damp 3.0%Damp 5.0%Damp OPk GPk GPk .62 .56 .50 1.56 L36 1.03 L82 1.55 121 L40 124 L08 1.68 L44 1.12 L51 1.27 1.04 L92 1.66 1.38 2-03 1.78 1.61 L73 1.59 1.39 2.71 228 1.81 3.24 2.68 2.06 248 212 1.93 2.97 2.60 2.11 3.31 2.85 2.22 3614 2.94 2.50 3.31 3.00 2.61 4.45 3.89 3.21 3.90 3.39 3.23 5.92 4.95 3.80 4.77 4.18 3.41 535 4.71 4.07 7.00 6.03 4.99 10.45 8.19 6.04 9.03 731 5.64 5.86 5.51 4.82 5.98 5.19 4.26 458 3.96 3.34 3.48 2.97 2.77 434 3.66 2.90 6.08 5.06 3.84 926 738 5.27 722 5.79 4.35 435 4.08 3.61 3.80 3.45 2.98 3.20 3.13 2.93 332 317 2.94 2.93 2.83 2.68 2.45 2.40 2.36 2.55 238 2.18 4.00 3.61 2.96 3.72 3.31 2.82 7.0%Damp GPk .44 .84 1.03 .98 .93 .92 19 L43 1.27 L55 1.71 L72 180 L86 2.17 231 2-75 2.99 3.13 2.94 3.56 4.45 4.91 4.62 421 3.72 2.98 2.61 2.62 3.34 4.20 3.74 3.29 2.71 2.76 2-79 2.58 2-33 2.22 2.55 2.54 LZRPLOT Ver. Z2n 03-22-2012

TEST RESPONSE SPECTRA Data FMIe: Q1206006 22-12 2: 49p Accel No. 8 1/6 Octave ZPA: 2.10 gPk REQUIRED RESPONSE SPECTRA RRS Mile: QI206SSE.RRS 22-12 9:19a A cc e e r a t i (g's) 50.0 30.0 20.0 10.0 7.0 5.0 3.0 2.0 1.0 .7 .5 I AXI t ~--q-~--t-t-t---- - ~ ~ 7r, R "kl:, I i i~

~

~ ~ 4--7-- -7 -7 +7 -1 t I* > CD -m -vCn o 3: L~t~i:i:LLW1~itJ .3 .2 .I A I 2 3 4 5 6~ 78 10 Frequency (He-ri) 20 30 40 50 6D 70 90 100 LZRPLOT Ver. 2.ln 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 135 TEST RESPONSE SPECTRA Data File: Q1206006 22-12 2.49p Accel No. 8 1/ 6 Octave ZPA 2.10 gPk Required Response Spectra REQUIRED RESPONSE SPECTRA RRS File: Q1206SSE.RRS 2242 9:19a Fre ao Accel .50 1.50 Fre Accel 20.00 ..50 Freq 50.00 100.00 Accel .50 .50 Test Response Spectra Freq 1.12 1.26 1.41 1.58 1.78 2-00 2.24 251 282 316 3.55 3.98 4.47 5.01 5.62 631 7.08 7.94 8.91 10.00 1122 1259 14.13 15.85 17.78 19.95 22.39 25.12 2818 31-62 35.48 39.81 44.67 50.12 56.23 63.10 70.79 79.43 89.13 100.00 .5%Damp GPk 131 2.91 1.63 180 138 2.98 2.63 5.20 3.83 5-36 7.02 9.95 7.02 696 9.25 10.37 27.51 41.86 25.62 12.68 7.40 4.17 3.99 3.16 3.52 522 3.60 3.73 3.05 3.44 3.44 2.50 2.88 2.49 313 4.55 381 4.12 4.25 513 3.47 2.0%Damp GPk .99 L56 L18 1.10 1.19 202 L91 2.71 3.45 357 388 4.90 4.07 4.28 6.69 6.82 15.85 21.12 16.57 &10 521 3.36 2.99 283 2.79 3.34 3.16 2.98 2.73 2.63 2.59 2.22 2.43 2.22 289 3.66 3.63 3.87 3.67 3.58 2.63 3D0bDamp GPk 84 130 1.05 L01 .11 167 1.64 215 3.01 3.03 3.19 391 3.72 3-92 5-97 6.06 1334 16.61 13.84 7.63 4.79 3.38 2.99 2.77 2.68 3.18 3.00 2.77 2.61 2.45 2.35 216 2.36 2.27 2.80 3.20 3.46 3.59 3.52 3.22 2.54 5.0%Damp GPk .67 1.02 .84 .87 .97 L29 133 1.67 2.35 239 2.42 2.85 3.22 3.45 4.83 5.30 10.14 11.85 1021 6.29 4.13 334 2.94 2.67 2.63 2.95 2.78 2.56 2.53 2.26 2.22 2.10 2.25 228 2-64 2.78 3.19 3.27 3.27 2.79 2.48 7.0%Damp GPk .58 .86 .73 .77 .88 L07 1.14 L40 1.90 2.14 1.99 2.37 2.86 3.12 4.06 4.98 828 9.55 8.34 5.39 3.94 3.28 2.89 2.63 2.60 2.77 2.62 2-47 2.45 2.19 2.13 2.05 2.19 2.24 2.51 2.70 2.98 3.06 3.09 2.69 2.52 LZRPLOT Ver. 2.1n 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206006 22-12 2 :4 9)p Accel No. 9 1/6 Octave ZPA: 1.38 gPk REQUIRED RESPONSE SPECTRA RRS Mile: Q1206SSE.RRS 22-12 9:19a 25.0 10.0 7.0 5.0 y F

  • w.

A c C I e r ati 0 (91s) 3.0 2.0 1.0 .7 .5 til IZ 1f .1..W 0.0 .3 .2 .1 ..v Frequency (Hertz)

  • .BV W
  • rV w
  • V

&w LZRPLOT Ver. 2.1n 03-22-2012

Report No. EGS.TR-HC589-01 Appendix II, Page No. 137 TEST RESPONSE SPECTRA Data File: Q1206006 22-12 Z-49p REQUIRED RESPONSE SPECTRA Accel No. 9 1V6 Octave ZPA: 18 gPk RRS File-Q1206SSE.RRS 22-12 9`19a Required Response Spectra Fre Accel Fr Fre Accel .50 0e0 150 50c _50 3.00 1.50 20.00 .50 100.00 .50 Tcst Response Spectra Freq .5%Damp 2.0%Damp 3.0%Damp 5.0%Damp 7.O0%Damp (h GPk GPk GPk GPk GPk .75 .63 .57 .50 .45 1.12 2.23 1.55 1.35 1.03 .83 1,26 2.36 176 1.50 1.18 .99 1.41 2.21 131 117 1.03 .93 1.58 2.53 1.59 136 1.07 .89 1.78 2.08 1.49 125 .99 .88 2.00 2.84 1.82 1.59 1.33 1.15 2.24 2.79 190 1.78 1.58 139 2.51 1.95 1.67 1.53 1.34 1.23 2.82 4.26 256 2.17 1.72 L49 3.16 5.65 3.17 2.62 2.01 1.66 3.55 3.91 2.29 2.12 1.88 1.67 3.98 4.38 2.84 2.47 2.01 1.71 4.47 3.62 3.21 2.75 2.14 L79 5.01 4.68 3.05 2.84 2.41 2.09 5.62 629 3.03 2.73 2.38 2.10 631 5.67 4.04 3.63 3.02 2.59 7.08 6.47 3.70 316 2.90 2.69 7.94 7.72 5.26 4.42 3.40 2.79 8.91 7.59 4.15 3.66 3.00 2.57 10.00 6.80 4.59 196 331 2.90 1122 8.60 5.51 4.74 3.89 3.48 12.59 17.08 &05 632 4.55 3.72 14.13 10.25 6.60 539 422 3.50 15.85 5.77 3.93 3.72 3.33 2.98 17.78 4.54 3.42 3.04 2.59 232 19.95 2.59 211 zoo2 188 1.81 22.39 2.75 2.19 2.04 185 1.72 25.12 3.37 2.16 191 1.83 1.78 2818 3.67 2.98 2.65 2-29 210 31.62 4.94 3.21 2.84 2.47 2.24 35.48 6.66 421 3.63 2.88 2.47 39.81 5-15 3.00 2.68 2.30 2.07 44.67 5.99 3.90 3.41 2.83 2.51 50.12 4.14 2.80 2.65 2.47 2.31 56.23 4.36 3.12 2.70 2.26 2.01 6310 3.78 2.74 2.51 2.19 1.99 70.79 4.43 232 2.20 2.09 1.93 79.43 3.81 2.56 2.26 1.96 1.79 89.13 3.90 2.76 2.49 2.09 1.82 100.00 4.30 197 2.72 2-35 2.09 LZRPLOT Ver. 2.In 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206006 22-12 2 :4 9p Accel No. 10 1/6 Octave ZPA: 2.27 gPk REQUIRED RESPONSE SPECTRA RRS File: Q1206SSE.RRS 22-12 9:19a 50.0 30.0 20.0 10.0 7.0 A c c r a t i 0 n 5.0 3.0 2.0 T...... ,.'T.-I........... ______~ j eI N.. I ___

4 oCl) 00 1.0

.7 .5 .3 .2 .1 )0 Frequency (Hertz) LZRPLOT Ver. 2. In 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 139 TEST RESPONSE SPECTRA Data File: Q1206006 22-12 2:4 9p Accel No. 10 1/6 Octave ZPA&- 227 gPk REQUIRED RESPONSE SPECTRA RRS File: Q1206SSE.RRS 22-12 919a Required Response Spectra Frq Accel Freq .O50 10.00 3.O 1.50 20.00 Test Response Spectra Freq .5%Damp GPk 129 L12 2-92 126 1.65 L41 1.84 1.58 1.37 L78 2.97 2.00 2.58 2.24 518 2.51 3.80 2.82 5.08 3.16 6.69 3.55 9.43 3.98 6.45 4.47 6.49 5.01 &01 5.62 8.72 6.31 22.41 7.08 32.21 7.94 19.31 8,91 9.06 10.00 4.92 1122 3.39 12.59 2.98 14.13 3.53 15.85 3.88 17.78 4.75 19.95 6.09 22.39 5.13 25.12 4.13 28.18 3.37 31.62 3.20 35.48 3.99 39.81 3.81 44.67 5.03 50-12 3.97 56.23 4-56 6310 6.20 70.79 7.87 79.43 1035 8913 10.67 100.00 9.77 Accel 1.50 .50 2.0'Damp GPk .98 L55 1.20 L13 120 2-01 1.86 2.70 3.39 3.39 3.64 4.64 3.68 3.73 5.82 5.63 12.65 16.26 12.27 5.96 3.80 2.61 2.66 3.07 3.02 3.92 438 3-50 3.41 2.33 2.68 3.06 3.03 3.73 3.48 3.87 4.69 4.95 7.38 6.74 6.23 Fre 5.00 100.00 Accel .50 .50 3.0%Damp GPk S4 m30 L06 .99 L11 1.65 1.59 211 2.95 288 2.98 3.69 3.40 3.48 5.21 .5.01 10.66 12.78 1027 5.60 3.50 2.65 2.57 2.89 2.81 3.51 3.74 3.20 3.09 2.25 2.57 2.75 2.84 3.44 3.42 3.67 433 4.57 620 619 534 5.0%Damp GPk .66 102 .83 .86 .97 127 1.28 1.63 2.28 2.28 2.24 2.69 2.95 3.08 4.23 4.28 811 9.16 7.61 4.62 3.18 2.62 2.42 2.61 2.50 290 2.99 277 2.71 2.21 2.41 Z49 2.58 3.18 .3.29 3.50 3.90 4.08 4.73 5.08 4.35 7.0%Damp GPk .57 .86 .72 .76 .88 L05 1.09 137 1.84 2.03 1.83 Z2.3 2.62 2.79 3.55 4.06 6.67 739 6.29 4.10 3.01 2.57 2.33 2.40 2125 2.54 2.68 2,49 2.49 222 2.33 239 2.53 2.99 -3.15 3.36 3.62 3.64 3.95 4.45 3.91 LZRPLOT Ver. 2.ln 03-22-2012

TEST RESPONSE SPECTRA Data File: Q1206006 22-12 2:49p Accel No. 11 1/ 6 Octave ZPA: 2.07 gPk REQUIRED RESPONSE SPECTRA RRS File: QI206SSE.RRS 22-12 9:19a 25.0 10.0 7.0 5.0 --i-__ L-El-- I _,J....... L, 1 _ _I i

i ! i
  • I I

I I f R 44 I /I / I I I -1 A cC r a ti 0 (g's) 3.0 2.0 1.0 .7 .5 -i~~e -7I ~.

1. 7__

'E,...i_..i.*~~~... i -,.= [ i

  • 'T t:

> mp -CL .3 .2 .1 L* !1 Z 1 4 o I 1 I0 Frequency (Hertz) 20 30

40) 50 60 70 8D 10 LZRPLOT Ver. 2.ln 03-22-2012

Report No. EGS-TR-HC589-01 Appendix II, Page No. 141 TEST RESPONSE SPECTRA Data File: Q1206006 22-12 2149p Accel No.11 1/6 Octave ZPAL 2.07 gPk Required Response Spectra Fre Accel F0.q Accel Fr Accel O1.50 1-50

56.

.50 3.00 1.50 20.00 .50 100.00 .50 REQUIRED RESPONSE SPECTRA RRS File: Q1206SSE.RRS 22-12 9.19a Test Response Spectra Freq .5%Damp (hZ GPk 1..50 112 1.93 1.26 221 1,41 177 1.58 2.35 1.78 2.31 2.00 3.28 2.24 3.66 2.51 4.07 2.82 3.97 3.16 5.25 3.55 4-32 3.98 3.77 4.47 4.84 5.01 5.20 5.62 5.20 6.31 412 7.08 6.07 7.94 6.41 8.91 8.59 10.00 4.75 11.22 3.37 12.59 2.44 14.13 2.33 15.85 316 17.78 2.80 19.95 2.59 2239 4.00 25.12 4.31 28.18 3.42 31.62 2.86 35.48 3.03 39.81 3.12 44.67 3.63 50.12 4.54 56.23 4.97 63.10 6.55 70.79 6.72 79.43 7.55 89.13 9.30 100.00 10.89 2.0%Damp 3.0%Damp 5.0%Damp GPk OPk GPk .84 .69 .55 1.16 .94 .75 1.68 1.43 1.08 1.44 1.28 1.04 L66 1.37 L04 L70 1.44 1.16 1.94 1.56 114 2.23 1.84 1.46 2.24 1.93 1.55 2.69 233 1.89 2.88 228 1.62 2.43 2.10 1.71 2.63 2.36 1.87 2.74 2.22 L77 2.76 2.53 2.14 2.92 2.35 1.93 2.95 2.70 2.26 3.55 3.14 2.57 3.71 295 2.43 3.86 3.14 2.47 3.54 2.88 2.23 2.08 1-90 L69 1.71 1-58 1.49 1.51 1.55 1.54 1.94 1.72 1.45 L79 1.63 1.44 1.85 1.82 L68 2.50 2.16 1.68 2.47 2.11 1.77 2.67 2.37 2.00 2.01 1.83 1.71 2.21 2.10 1.92 2.66 2.51 221 2.39 2.04 1.83 2.75 238 2.4 3.85 3.58 3.17 5.47 4.87 3.94 5.40 4.65 4.12 6.34 5.96 5.39 7.53 698 6.09 7.23 5.93 5.53 7.0%Damp GPk .47 .63 .92 .87 .86 LOO 1.03 126 135 1.59 134 L47 L62 1.59 1.87 1.78 189 2.20 2.22 2.16 191 166 L49 151 L.28 L33 L54 1.49 L61 L78 L65 L78 196 L75 L94 2-86 3.34 3.81 4.84 5.44 519 LZRPLOT Ver. 2.n 03-22-2012

Report No. EGS-TR-HC589-01 Page No. 142 Part 3 Transmissibility Plots I CIJRTWS wControl Company Quat Tech Nlp 125 West Park Loop, Huntsville, AL 35806 Tel (256) 722-8500 Fax (256) 722-8533

Report No. EGS-TR-HC589-01 Appendix II, Page No. 143 Resonance Search Transmissibility Plots

Report No. EGS-TR-HC589-01 Appendix I1, Page No. 144 CL q1206 x ch4 top of cabinet Freql Transml Freq2 Transm2 Freq3 Transm3 15.2436 7.48003 0 0 0 0 10 10 uj v-9L a, =.1 10 4 10 2 10 FREQUENCY

Report No. EGS-TR-HC589-01 Appendix II, Page No. 145 a. 400 300 200 100 0 q1206 y ch5 top of cabinet Freql 7.70105 Transml 8.47625 Freq2 31.55 Transm2 2.9974 -MWN 31491 10 2 10 UJ 0 1- <~ 10o 10 - 0 10 10 FREQUENCY

Report No. EGS-TR-HC589-01 Appendix II, Page No. 146 (2 250 200 I60 100 so 0 q1206 z ch6 top of cabinet Freqi Transml Freq2 Transm2 Freq3 Transm3 0 0 0 0 0 0 10 uJ 10 -Ja-10 10 a 10 FREQUENCY

Report No. EGS-TR-HC589-01 Appendix II, Page No. 147 400 S a. 200 qi 206 x ch7 back of cabinet Freql Transml Freq2 Transm2 Freq3 Transm3 15.2436 7.93465 27.2093 2.4133 34.0748 7.76843 10 S10 10 10 01 10 10 FREQUENCY

Report No. EGS-TR-HC589-01 Appendix II, Page No. 148 0. q1206 y chS back of cabinet Freql Transml Fmeq2 Transm2 Freq3 Transm3 7.70105 7.44114 13.7245 2.85738 0 0 u. a 10 10 10 10 10 U fl fl I U U I a m m U I 1 m m U I 2 - m U U I U U I U I I a 10 0 10 FREQUENCY

Report No. EGS-TR-HC589-01 Appendix 11, Page No. 149 a-400 200 0 q1206 x ch9 monitor side Freqil Transml Freq2 Transm2 Freq3 Transm3 15.1455 5.33522 48.1487 2.59946 0 0 10 U.' D 10 -.J 10 10 D 10 10 FREQUENCY

Report No. EGS-TR-HC589-01 Appendix II, Page No. 150 0 a-l 400 300 200 100 0 q1206 y chlO monitor side Freqil Transml Freq2 Transm2 Freq3 Transm3 7.70106 5.68628 13.7245 2.78387 43.0097 2.21799 10 ku a L-10 -J 10 10 -2_ii 0 10 10 FREQUENCY

Report No. EGS-TR-HC589.01 Appendix II, Page No. 151 0 a-I 250 2O 150 100 50 0

1 ::

-dw -2 M 0o1 ME1 q12O z chllI monitor side Freqil Transml Freq2 Transm2 Freq3 Transm3 33.1769 3.19292 0 0 0 0 .JI-a- CL 1 1

      • d.*,.*.*

a I 0 10 10 FREQUENCY

Report No. EGS-TR-HC589-01 Page No. 152 Part 4 Equipment Used Sheets I Qualrech AIP 125 West Park Loop, Huntville, AL 35806 Tel (256) 722-8500 Fax (256) 722-8533

Report No. EGS-TR-HC589-01 Appendix II, Page No. 153 Calibrated Equipment Log

Report No. EGS-TR-HC589-01 Appendix 11, Page No. 154 0 97J1Jf11 pA1Nt TEST LOG FOR SEISMIC QUALIFICATION PROGRAMS Clie°nt; ix/' Me/-,,,,/ ContractNo.: C T__5`7 9 Test Plan No.I Rev No.: (9,.12- ,o 0 / & L-, 0 Prior to the bringing items to the seismic table for testing, the following shall be verified by the EQ Project Coordinator: CHECKPOINT REMARKS PERFOBY.IONERIRtED BY: INITIALJDATE Test Plan Approval er 6uaITech NP [3 Client___ 7RevI Contract for Hold-points W-~s x~ A'pplicable 0 Not Applicable3 Test Sample Log Updated 4 ist any Nonconformance Reports Generated for Test N 6K-//. Samples The following tasks shalt be initialed and dated by qualified EQ personnel performing or verifying the respective task: PERFORMEDNERIF1ED CHECKPOINT REMARKS BY: iTIArn ATE Seismic Test Setup and Mounting Completed and gT-3-, Documented 45 ;z 1*2.- Verify and Record Test Sample on the Seismic Table (Nm by Test Item Number 3 /2 Calibrated Equipment Usage List Updated I.- t, Z Photographs of Test Setup Taken Ic aIo-ImI z 7.,z Resonance Search Teat Performed 2-Ie,* ?tA Visual Inspection for Structural Integrity I < /2 z-7 RESPONSIBLE EQ PERSONNEL APPROVAL DATE:2 The client signatures below Indicatehat the persons listed were at the QualTech NP facility to witness the seismic testing for the contract and customer listed above CLIENT SIGNATURE-DATE: CLIENT SIGNATURE: DATE: 162-03-98, Rev.3 (Note: Blank form Is 3 pages.)

I 07Mu we TEST LOG FOR SEISMIC QUALIFICATION PROGRAMS Report No. EGS-TR-HC589-O1 Appendix II, Page No. 155 I SEISMIC TESTING REMARKS 0] SSE Li Fragility Visual Inspection for Structural Integrty Functlonal Check Performed By: QOualTech NP E] Client ~4zz-/iz. Aiw4 010p;ý6 Test 7-, OBE E TRS-Envelope-D-4es N JSSE RRS 0 No OFragility ElN/A 0 '3 Visual Inspection for Structural Integrity FLictional Check Performed By: QualTech NP El Client Test B

  • PSE 3

TRS-Envelope - tYes OSSE RS UNof O Fragility El NIA fo Visual Inspection for Structural Integrity 4Fctional Check Performed By: QualTech NP 0l Client Test OBE TRS-Envelope - Yes LIP LIPSSE __RRS KNo C3 Fragility C3 NIA Visual Inspection for Structural Integrity Functional Check Performed By: .-Quarrech NP El Client Test 5 JOBE

  • r TRS-Envelope -

)*-Yes RN, 0 SSE __RRS [IlNo2 Cl Fragility El N/A Visual Inspection for Structural Integrity Functional Check Performed By: WLQualTech NP El Client Test.(a -SEl OBE TRS-Envelope - Rl-es EFSSE T RRS El No [I Fragility .[ N/A Visual Inspection for Structural Integrity Functional Check Performed By: V.QuaiTech NP ElClient AN, / 115ii 124* $60 Test OBE TRS-Envelope - El Yes 0 SSE RRS [I No 0l Fragility El N/A Visual Inspection for Structural Integrity Functional Check Performed By: -I QualTech NP El Client Test _E OBE TRS-Envelope - El Yes [I SSE RRS 0 No El Fragility El N/A E Visual Inspection for Structural Integrity Functional Check Performed By: Dl QualTech NP El Client 162-03-98. Rev.3 (Note: Blank form is 3 pages.)

MVz~aM' Report No. EGS-TR-HC589-01 Appendix II, Page No. 156 TEST LOG FOR SEISMIC QUALIFICATION PROGRAMS PERFORMEDNERIFIED SEISMIC TESTI NG REMARKS BY: INITAUDATE Test D_ OBE TRS-Envelope - Li Yes 0 SSE RRS 0 No o Fragility 0 N/A 0 Visual Inspection for Structural Integrity Functional Check Performed By: [3 Quaflech NP Li Client Test D OBE TRS-Envelope - EJ Yes [I SSE RRS C1 No 0i Fragility 0 N/A 0 Visual Inspection for Structural Integrity Functional Check Performed By: [I QualTech NP [I Client Test C_ OBE TRS-Envelope - 0i Yes [SSE RRS C]No El Fragility [I N/A Visual Inspection for Structural Integrity Functional Check Performed By: Ci QualTech NP EL Client Test [ iOBE TRS-Envelope - Li Yes []SSE RRS LiNo 0i Fragility 0i N/A L Visual Inspection for Structural Integrity Functional Check Performed By: 0i Quaflech NP L] Client Test _L OBE TRS-Envelope - [] Yes []SSE RRS 0 No Li Fragility ONIA Visual Inspection for Structural Integrity Functional Check Performed By: Li QualTech NP Li Client MANDATORY CHECKPOINT Seismic Test Approval is required by the Responsible EQ Personnel. The Seismic test criteria were met with any discrepancies recorded on the applicable Nonconformance R,rt(s). APPROVED BY: 7 1Q/.0..(. Y -Y-kQ.- DATE.: ~ MANDATORY CHECK POINT REMARKS -INITIALJDATE Post Seismic Functional Test Performed and Reviewed ( 3 Is31-SI l All Test Data Acquired and Documentation Recorded All Nonconformance Reports Closed ,1./ I Post Seismic Functional Test/Documentation Approval is required by the Responsible EQ Personnel. The Seismic Test Plan was met with any discrepancies being recorded on the applicable Nonconformance Report(s). COMMENTS: 1~ DATE: APPROVED BY: -I.- I --3 Total Number of Pages in this log: 162-03-98, Rev.3 (Note: Blank form Is 3 pages.)

Report No. EGS-TR-HC589-01 Appendix II, Page No. 157 QUALTECH TP Q1206.0 REV.O PG 10 Seismic Operability Data Sheet For Test Switch Panel Test # Test Checing for (to be edmabramsb) OBEI OBE 2 ",OBE .3 Structural Integrity ....... f OBE4 57= OBE 5 ¢, SSEI SSE 2, Infrument and Equipment List Serial No. Range Calibration Due Test Set-Up Reviewed Byl~ate: ~11X3d.]J Test # Structural Integrity Maintained I NO /NQN S/IND ( _ /NO I NO SSi NO YES / NO YES/NO YES/NO Notes: Compied wO Test ReqVren/ents: C Tested By/Date: NCR Number: if's Reviewed B~;.j '/2 f. V

Test Sample #:4j12o,-oI-o-. I

== Description:== QA*&ie*r At.cAaebhIIc Fixture: YVertical -- Horizontal Other:_ Thickness inches Hardware: Size: TY: Torque: 21F t- ..k6Commercial Grade -- Mir. Supplied -- SAE Grade iScrews/Bolts . Nuts 2Flat Washers _--'.ock Washers

  • Other:

Mass Loading: Wire Flexible Conduit "Tubing - Pipe Other: Size/Gauge: Length: Calibrated Equipment Used: -,Asset ID: 0'13.O Asset ID: Asset ID: Test Sample #:

== Description:== Fixture: 0 Vertical O Horizontal - Other:. Thickness inches Test Sample #:

== Description:== Fixture: 2 Vertical _ Horizontal [- Other:_ Thickness inches 4. Hardware: Size: QTY: Torque: Commercial Grade Mfr. Supplied SAE Grade Screws/Bolts _- Nuts Flat Washers Lock Washers Other: Mass Loading: . Wire .__ Flexible Conduit "" Tubing - Pipe Other: Size/Gauge: Length: Calibrated Equipment Used: - Asset ID: _ Asset ID: L-* Asset ID: Hardware: Size: QTY: Torque: .J Commercial Grade

  • _ Mfr. Supplied SAE Grade 7, Screws/Bolts 7 Nuts Flat Washers

- Lock Washers Other: Mass Loading: .:Wire -Flexible Conduit -" Tubing -1 Pipe Other. Size/Gauge: Length: Calibrated Equipment Used: ,- Asset ID: 7 Asset ID: Asset ID: Test Sample #:

== Description:== Fixture: r1 Vertical 2 Horizontal Other: Thickness _ inches Hardware: Size: CITY: - Torque: ._ Commercial Grade Mir. Supplied - SAE Grade Screws/Bolts Nuts "- Flat Washers Lock Washers

r. Other:

Mass Loading: -Wire Flexible Conduit -- Tubing -- Pipe Other: Size/Gauge: Length: Calibrated Equipment Used: LAsset ID: r-Asset ID: -- Asset ID:_ P00 q.... I i K icr n,.lu.. ,,l.f., n -ar-lS o, f~ .fl. ý -IW a.,.r Aila I -r C.,taý 1.2AM= J -LQ - 1016 a W ig jfr& i.Lh

iI PerformedB 164-03-98. Rev. 5 D rate:-2-1 Reviewed By. Date

Report No. EGS-TR-HC589-01 Appendix II, Page No. 159 CALIBRATED EQUIPMENT USAGE for CONTRACT # CJ1579/Q1206SE AseD Seia Nu.e Caibato D Date3. 28.5 70186 5/27/2012 792.0 151127 6/14/2012 794.0 151130 6/14/2012 795.0 150764 6/14/2012 3.5 2754 12/20/2012 5.3 2778 10114/2012 8.0 5379 9/1/2012 13.0 21832 5/27/2012 16.0 22208 5/6/2012 25.0 22217 5/27/2012 18.0 22210 5/6/2012 2.0 237 7/8/2012 747.0 P64689 5/15/2012 813.0 5110348546 11/4/2012 278.0 9179 12/29/2012 i

APPENDIX III (6 Pages) Notice of Anomaly 2012-010, Non Conformance Report NCR #12-65 Rev. 0, and Certificate of Conformance #CJ 1579.1 I Qua Ilech NP 125 West Park Loop, Huntsville, AL 35806 Tel (256) 722-8500 Fax (256) 722-8533

Report No. EGS-TR-HC589-01 Appendix III, Page No. 1 NOTICE OF ANOMALY A"TE: April 19, 2012 Notice No.: 2012-010 (2 Pages) P.O. No.: Customer Supplied under 1i-017 Contract No: HC589 Customer. OualTech NP Cincinnati Job No.: HJ1769 Notification Made To: Lynn Saul Notification Date: March 28.2012 Notification Made By: Donald Bentley Via: Teleconference Category: Specimen X Procedure Test Equipment Date of Other Anomaly. March. 22,2012 REPORTABLE PER I OCFR2 1: YES X NO Part Name: ICCMS Cabinet Assembly Part No.: NUS-CI30PA-1 Test: Seismic Testing I.D. No.: N/A Specification: TP S1206.0 Rev 0 Paragraph No.: Attachment B of 0 1206.0 Rev. 0 REQUIREMENTS: Post Resonance Search - Repeat Base resonance search in its entirety. DESCRIPTION OF ANOMALY: The ICCMS Cabinet Assembly was not subjected to a post seismic resonance search. DISPOSITION - COMMENTS - RECOMMENDATIONS: The post seismic resonance search is typically performed on assemblies to detect mechanical fatigue or the shifting of internal components. The cabinet assembly was tested utilizing dummy masses to simulate the in situ configuration. The shifting of the dummy masses, which only represented the potential weight of to be installed components, could result in erroneous changes in the system resonances. Also, the resonance search accelerations far exceeded the SSE conditions for the proposed installation location of the cabinet. The cabinet having already been subjected to the OBE and SSE level conditions, and one series of resonance searches showed no signs of mechanical fatigue or structural failure. An email from the customer confu'ns agreement with this disposition. Attachment I: Email from Lynn Saul on 3/2820 12. Verification: Project Engineer.W 617 Test Witness: A)/"- Program Manager. Z--- Representing:: I//k independent Quality Assurance: ol el 1 Technical Review.A L Z. Form 1511 - Revised 18MAY20 10

Report No. EGS-TR-HC5W9-01 Appendix Il1, Page No. 2 Attachment I to NOA 2012-010 Page 1 of I Bentley, Donald From: Sault Lynne Sent Wednesday, March 28, 2012 9:47 AM To: Bentley, Donald; Thelen, Matthew c* Queenan, Robert Street Richard; tomc@hursttecl*com; Leung, Henri Subject Resonance test on cabinet

Don, As we discussed,. performing the resonance test first, prior to the six seismic tests, is acceptable to Scientech. You do not need to perform a second resonance test after the seismic tests.

Lynne Saul, PMP St. Project Manager Scientech, a business unit of Curtiss-Wright Flow Control Company Phone: 208-524-9371

Report No. EGS-TR-HC589-01 Appendix III, Page No. 3 Non Conformance Report NCR #12-65 Rev. 0

Report No. EGS-TR-HC589.01 Apeni m, Pag No. 4 NONCONFORMANCE REPORT {NCR) -0F1owConteol Company 12-65 Rev.: 0 QusiTeeh NP Contract #: CJ1579 Customer QualTech NP Huntsville QualTech NP ID: Q1206-01-01-01 Item

Description:

NUS Instruments Cabinet Assembly Mfr NUS Mfr PN: NUS-A321XD Drawing # IRev.: I MWO (Master BOM) # I Rev.: I Item Classification: Safety Related Traveler (Job Operation Listing Report) # I Rev.: I NCR Written Against Ops - EQ Finding:

  • Resonance search was not performed after the seismic test. It was only performed before the seismic test Reported By: Marie Nemier Date:

3/28/2012 Disposition:

  • W] Use-As-Is S Rework EU Repair I'l Scrap EU Return to Vendor Ul Return to Customer U Replace with new or alternative Test Sample U) Condition noted Is ACCEPTABLE {no limitation) based on the clarification presented below EU Other (alternate disposition not categorized above - provide complete details and justification)

Remarks:

  • The purpose of the resonance search after the seismic test was to determine if there was any post-seismic damage after the test by comparing the pre and post seismic resonance search for variations. A complete and thorough visual inspection was performed finding no post-seismic damage.

Customer Approval Required: 25 Yes EU No Dispositioned By: MarieNe erner. QA Approval: gregory Predmore Customer Approval: .s r A C'H 0;o Date: 3/28*2012 Date: 3/28/2012 Date: NCR Assigned to (Responsible for completion):_O*s - EQ Date Due: 4127/2012 Actions Taken to Complete Disposition: No further action requijrqed.Disposition accep epd b customer. Seeattached e-mail. D ispositio n C om pleted B y: M arie N em ier....................................................................................................... D ate:....... 3/28120.12 Does the finding represent a defect, deviation, or failure to comply as defined U Yes W No within 10CFR Part 21? Is further evaluation required per generation of a Corrective Action Request (Form 039-05-90)? 66 No - Completion of approved disposition will be sufficient. 7 Yes - CAR # N/A Initiated QA Approval: Gregory Predmore Date: 3/28/2012 All actions required to cl #'1e NCR have been accomplished and documented. QA Approval: Date: 3/28/2012 ANI Acceptance: PA......Date: jK A Aetach additional suo Ii

tat, o

(I.e., calculationscorrespondence, photographs, etc.) as neccessary.

  • A disposition of 'Rework' is NOT allowed for ASME materiaL 052-06-90 Rev. 14 Page I of I

Report No. EGS-TR-HC589-01 Appendix III, Page No. 5 Myers, Adrienne From: Bentley, Donald Sent: Wednesday. March 28, 2012 10:53 AM To: Duffey, Josh Cc: Myers, Adrienne; Thelen, Matthew

Subject:

FW: Resonance test on cabinet Please ship the module back to Scientech ASAP, we will also need a data package and C of C to generate a report to ship by month end.

Thanks, Donald Bentley !iI Project Engineer, QualTech NP Huntsville Operations, a business unit of Curtiss.Wright Row Control Company Office No.: (256) 722-8500 Ext. 127 125 West Pa,* Loop Huntsville, AL 35806 From: Saul, Lynne Sent:. Wednesday, March 28, 2012 9:47 AM To: Bentley, Donald; Thelen, Matthew Cc: Queenan, Robert; Street, Richard; tomc)hursttech.com; Leung, Henri

Subject:

Resonance test on cabinet

Don, As we discussed, performing the resonance test first, prior to the six seismic tests, is acceptable to Scientech. You do not need to perform a second resonance test after the seismic tests.

Lynne Saul, PMP Sr. Project Manager Scientech, a business unit of Curtiss-Wright Flow Control Company Phone: 208-524-9371

Report No. EGS-TR-HC589-01 Apperidix Il, Page No. 6 CERTIFICATE OF CONFORMANCE # CJ1579.1 TO: QualTech NP 125 West Park Loop Huntsville, AL 35806 FROM: W I QU.Ifwhc NP 4600 East Tech Drive Cincinnati, Ohio 45245 (513) 528-7900 Purchase Order # Line Item # Quantity QualTech NP Project # QualTech NP Job Order # Test Procedure # Source

HP00001165
I
I CW98 C11579
Q1206.0 Rev. 0
QualTech NP, Cincinnati SUBJECT ITEMS COVERED BY THIS CERTIFICATE QualTech NP Test Sample Number Description and Part Number Q1206-01-01-01 NUS Instruments Cabinet Assembly Drawing #NUS-A321XD This document certifies that the subject items listed herein were tested in accordance with the QualTech NP, Huntsville Purchase Order referenced above. The items have been tested in accordance with IEEE 344-1987 and the QualTech NP Test Procedure listed above. The test item satisfactorily met all of the criteria in the test procedure and there was no structural damage noted after the test.

QualTech NP QA Manual Edition 2 Revision 1, Dated: 06/25/10; 10CFR50 Appendix B, IOCFR Part 21, ANSI N45.2-1977, and ASME NQA-1 were followed for qualification testing of the subject item. All activities were performed at Cincinnati, Ohio. Attached are the resonance search transmissibility plots, seismic TRS plots, test log, photograph and mounting and seismic test data sheets. It shall be noted that upon request of the end - user the front and rear doors were removed during the seismic test program. Non-conformance report NCR 12-65 was issued during the testing since the resonance search was performed before the seismic test not after the seismic test. The NCR was approved by the customer. Seismic & EQ Manager Date Qualit 1Date}}