05000397/LER-2016-003, Regarding Failure of Fan to Start Results in Momentary Increase in Secondary Containment Pressure

From kanterella
(Redirected from 05000397/LER-2016-003)
Jump to navigation Jump to search

Regarding Failure of Fan to Start Results in Momentary Increase in Secondary Containment Pressure
ML17012A322
Person / Time
Site: Columbia 
(NPF-021)
Issue date: 01/12/2017
From: Javorik A
Energy Northwest
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
G02-17-016 LER 16-003-00
Download: ML17012A322 (4)


LER-2016-003, Regarding Failure of Fan to Start Results in Momentary Increase in Secondary Containment Pressure
Event date:
Report date:
Reporting criterion: 10 CFR 50.73(a)(2)(v), Loss of Safety Function

10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded

10 CFR 50.73(a)(2)(viii)(A)

10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition

10 CFR 50.73(a)(2)(viii)(B)

10 CFR 50.73(a)(2)(ix)(A)

10 CFR 50.73(a)(2)(iv)(A), System Actuation

10 CFR 50.73(a)(2)(x)

10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor

10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat

10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown

10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications

10 CFR 50.73(a)(2)(vii), Common Cause Inoperability
3972016003R00 - NRC Website

text

ENERGY NORTHWEST G02-17-016 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Alex L. Javorik Columbia Generating Station P.O. Box 968, PE04 Richland, WA 99352-0968 Ph. 509.377.8555 I F. 509.377.4150 aljavorik@energy-northwest.com 10 CFR 50.73

Subject:

COLUMBIA GENERATING STATION, DOCKET NO. 50-397 LICENSEE EVENT REPORT NO. 2016-003-00

Dear Sir or Madam:

Transmitted herewith is Licensee Event Report No. 2016-003-00 for Columbia Generating Station. This report is submitted pursuant to 10 CFR 50.73(a)(2)(v)(C) and 10 CFR 50.73(a)(2)(v)(D).

There are no commitments being made to the NRC by this letter. If you have any questions or require additional information, please contact Ms. D.M. Wolfgramm, Regulatory Compliance Supervisor, at (509) 377-4792.

Executed on I.. / z - I 7 Respectfully, A. L. J vorik Vice President, Engineering

Enclosure:

Licensee Event Report 2016-003-00 cc: NRC Region IV Administrator NRC NRA Project Manager NRC Senior Resident lnspector/988C CD Sonoda - BPA/1399 WA Horin -Winston & Strawn January 12, 2017

NRC FORM366 U.S. NUCLEAR REGULATORY COMMISSION APPROVED BY OMB: NO. 3150-0104 EXPIRES: 10/31/2018 (06-2016)

Estimated burden per response to comply with this mandatory collection request: 80 hours9.259259e-4 days <br />0.0222 hours <br />1.322751e-4 weeks <br />3.044e-5 months <br />.

.,,...... ~~

Reported lessons learned are incorporated into the licensing process and fed back to industry.

~¥.\\

LICENSEE EVENT REPORT (LER)

Send comments regarding burden estimate to the FOIA, Privacy and Information Collections Ii Branch (T-5 F53), U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001, or by e-mail

\\, l (See Page 2 for required number of digits/characters for each block) to lnfocoilects.Resource@nrc.gov, and to the Desk Officer, Office of Information and Regulatory Affairs, NEOB-10202, (3150-0104), Office of Management and Budget, Washington, DC 20503. If a (See NUREG-1022, R.3 for instruction and guidance for completing this form means used to impose an information collection does not display a currently valid OMB control bUQ * [fwww nrc gQvLreadiog-[!Il[dog-coll!agtiQClSlntm~gslstafflsr:J 022Lr3L) number, the NRC may not conduct or sponsor, and a person is not required to respond to, the information collection.

3. PAGE Columbia Generating Station 05000 397 1 OF 3
4. TITLE Failure of Fan to Sta11 Results in Momentary Increase in Secondary Containment Pressure
5. EVENT DATE
6. LER NUMBER
7. REPORT DATE
8. OTHER FACILITIES INVOLVED I

SEQUENTIAL I REV FACILITY NAME DOCKET NUMBER MONTH DAY YEAR YEAR MONTH DAY YEAR NUMBER NO.

05000 FACILITY NAME DOCKET NUMBER 11 20 2016 2016. 003. 00 01 12 2017 05000

9. OPERA TING MODE
11. THIS REPORT IS SUBMITTED PURSUANT TO THE REQUIREMENTS OF 10 CFR §: (Check all that apply)

D 20.2201(b)

D 20.2203(a)(3)(i>

D 50.73(a)(2)(ii)(A)

D 50.73(a)(2)(viii)(A) 1 D 20.2201 (d)

D 20.2203(a)(3)(ii)

D 50.73(a)(2)(ii)(B)

D 50.73(a)(2)(viii)(B)

D 20.2203(a)(1 >

D 20.2203(a)(4)

D so. 13<a><2><iii)

D 50.73(a)(2)(ix)(A)

D 20.2203(a)(2)(i)

D 50.36(c)(1 )(i)(A)

D 50.73(a)(2)(iv)(A)

D 50.73(a)(2)(x)

10. POWER LEVEL D 20.2203<a><2><ii)

D 50.36(c)(1 )(ii)(A)

D 50.73(a)(2)(v)(A)

D 13.11ca><4>

D 20.2203ca>c2>cm>

D so.3scc>c2>

D 50.73(a)(2)(v)(B)

D 13.11<a>

D 20.2203(a)(2)(iv)

D so.4sca><3)(ii)

[{] 50.73(a)(2)(v)(C)

D 13.11<a>c1 >

97 D 20.2203(a)(2)(v)

D 50.73(a)(2)(i)(A)

[{] 50.73(a)(2)(v)(D)

D 13.11ca><2>

D 20.2203(a)(2)(vi)

D 50.73(a)(2)(i)(B)

D 50.73(a)(2)(vii)

D 13. 11<a>c2><ii)

D 50. 73(a)(2)(i)(C)

OorHER Specify in Abstract below or in

Similar Events

A loss of the ability to maintain Secondary Containment pressure greater than required by Technical Specifications has occurred at, and was reported by, Columbia Generating Station (Columbia) twice in the past two years. The first incident was the result of an incorrectly sized lug installed in the fuse block during initial construction and the second incident occurred when an exhaust air valve unexpectedly closed. Prior to this two year time period, Columbia has experienced losses of Secondary Containment due to weather-related conditions, as well as human performance errors. Columbia has implemented corrective actions for these previous events.

Further Corrective Actions Causal evaluation determined that the failure of the fan was a result of a faulty control switch; corrective actions are to replace the control switch for fan REA-FN-1 B. Additionally, the control switches for the System A exhaust air fan and both Reactor Building supply air fans will be replaced as well, as they are the same make, model, and age as the control switch in fan REA-FN-1 B.

Energy Industry Identification System (EllS) Information codes from IEEE Standards 805-1984 and 803-1983 are represented in brackets as [XX] and [XXX] throughout the body of the narrative. Page 3