05000397/LER-1996-001, :on 960425,inadvertent ESF Actuations Occurred Due to Tripping of Temporary Power Supply to IN-3.Caused by Personnel Error.Operations Restored to IN-3 Loads & Reset ESF Actuations

From kanterella
(Redirected from 05000397/LER-1996-001)
Jump to navigation Jump to search
:on 960425,inadvertent ESF Actuations Occurred Due to Tripping of Temporary Power Supply to IN-3.Caused by Personnel Error.Operations Restored to IN-3 Loads & Reset ESF Actuations
ML17292A286
Person / Time
Site: Columbia 
Issue date: 05/24/1996
From: Bemis P, Pfitzer B
WASHINGTON PUBLIC POWER SUPPLY SYSTEM
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
GO2-96-110, LER-96-001, LER-96-1, NUDOCS 9606040015
Download: ML17292A286 (9)


LER-1996-001, on 960425,inadvertent ESF Actuations Occurred Due to Tripping of Temporary Power Supply to IN-3.Caused by Personnel Error.Operations Restored to IN-3 Loads & Reset ESF Actuations
Event date:
Report date:
Reporting criterion: 10 CFR 50.73(s)(2)(i)

10 CFR 50.73(e)(2)

10 CFR 50.73(s)(2)(vi)

10 CFR 50.73(s)(2)
3971996001R00 - NRC Website

text

CATEGORY REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9606040015 DOC.DATE: 96/05/24 NOTARIZED: NO DOCKET FACIL:50-397 WPPSS

.Nuclear Project, Unit 2, Washington Public Powe 05000397 AUTH.NAME AUTHOR AFFILIATION PFITZER,B.

Washington Public Power Supply System BEMIS,P.R.

Washington Public Power Supply System RECIP.NAME RECIPIENT AFFILIATION

SUBJECT:

LER 96-001-00:on 960425,inadvertent ESF actuations occurred due to tripping of temporary power supply to IN-3.Caused by personnel error. Operations restored to IN-3 loads

& reset ESF actuations.W/960524 ltr.

DISTRIBUTION CODE:

IE22T COPIES RECEIVED:LTR I

ENCL

)

SIZE:

TITLE: 50.73/50.9 Licensee Event Report (LER), Incident Rpt, etc.

NOTES:

E RECIPIENT ID CODE/NAME PD4-2 PD INTERNAL: ACRS AEOD/SPD/RRAB NRR/DE/ECGB NRR/DE/EMEB NRR/DRCH/HICB NRR/DRCH/HQMB NRR/DSSA/SPLB RES/DSIR/EIB EXTERNAL: L ST LOBBY WARD NOAC MURPHYIG.A NRC PDR COPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 RECIPIENT ID CODE/NAME COLBURN,T AEOD SPD RAB CENT NRR/DRCH/HHFB NRR/DRCH/HOLB NRR/DRPM/PECB NRR/DSSA/SRXB RGN4 FILE 01 LITCO BRYCE,J H

NOAC POORE,W.

NUDOCS FULL TXT COPIES LTTR ENCL 1

1 2

2 1

1 1

1 1

1 1

1 1

1 1

1 1

1 2

2 1

1 1

1 0

D U

N 4'

0 IDS" REC PE~V PLEASE HELP US TO REDUCE WAS~TE!

CONTAC THE OCUMENT CONTROL DESK, ROON OWEN 5D-5 (EXT. 4i5-2083:

TO ELLi>ENATE OUR NATE FROi~!

D STREBUTTON LTSTS FOR DOCUNENTS YOU DON'T NEED.'ULL TEXT CONVERSION REQUIRED TOTAL NUMBER OF COPIES REQUIRED:

LTTR 26 ENCL 26

WASHliVGTOiVPUBLIC POWER SUPPLY SYSTEM PO. Box 968

~ 3000 George 1Visshingtott 1Vn)'

Richlnrut, 1Vashington 99352.0968

~ (S09) 372-SOOO May 24, 1996 G02-96-110 Docket No. 50-397 Document Control Desk U,S. Nuclear Regulatory Commission Washington, D.C. 20555 Gentlemen:

Subject:

NUCLEAR PLANT WNP-2, OPERATING LICENSE NPF-21, LICENSEE EVENT REPORT NO. 96-001-00 Transmitted herewith is Licensee Event Report No. 96-001-00 for WNP-2.

This report is submitted in response to the reporting requirements of 10CFR73 and discusses the items of reportability, corrective action taken, and action taken to preclude recurrence.

Should you have any questions or desire additional information regarding this matter, please call me or Ms. Lourdes Fernandez at (509) 377-4147.

tfully, y

. R.

emts at rop E20)

Vice President, Nuclear Operations Enclosure cc:

LJ Callan, NRC RIV JW Clifford, NRC KE Perkins, Jr., NRC RIV, WCFO NS Reynolds, Winston & Strawn NRC Sr. Resident Inspector, MD927N (2)

INPO Records Center - Atlanta, GA DL Williams, BPA, MD399 96060tI0015 960524 PDR ADQCK 05000397 P l3ft tg-,

~

jhl'

LICENSEE EVENT REPORT (LER)

FAcs(TY NAMEll(

DOCXET N(AIS(R (a tACE(%

Washington Nuclear Plant Unit 2 0

5 0

0 0

3 9

7 1

A 4

m(E(>>

INADVERTENT ESF ACTUATIONS DUE TO TRIPPING OF TEMPORARY POWER SUPPLY TO IN-3 BY OUTAGE ELECTRICIANS EV(NT DAVE (SI R(tORT DATE (11 FACE(TV NAM(S N/A OTN(R FACLITI(S t(VOLVTDle(

OOCXET IMIS(R(S I 0

0 0

04 25 96 96 0

0 1

0 0

05 24 96 0

0 opERATSIQ MODE (SI THS R(PORT IS SVOM(TTED PVRSVANI'O TIIE REOVTI(M(NTS OF 10 (TIL l(11 POW(R LLV(L 001 0

0 0

20.402(bl 20.405(e)(l)b)

J 20.405(e)(l)(ii)

I 20.405(e)() )(N')

( 20.405(e)(l )(ivl 20.405(sl(l )(v)

(

J 20.405c

( 50.38(c)(1(

J 50.38(cl(2)

[ 50,73(s)(2)(i)

) 50.73(s)(2)(i)

( S0.73(s)(2)(<<)

( X

] 50.73(e)(2)(ivl

)

( 50.73(e)(2)(vl J 50.73(s)(2)(vi) 50.73(e)(2)(vM)A J 50.73(s)(2)(vsr)B

( 50.73(s)(2)(xl 73.71(b)

( 73.71(c)

) OTHER (Specify in Abstract below end in Text. NRC Form 388A)

Uc(NS(E CONTACT FOR THS L(R (IN Bill Pfitzer, Licensing Engineer COMPLETE OIC Ls(E TO(I EACN COMPO(CRT FASIME D(SCRN(O t( THS R(PORT (ISI AR(A CODE 509 377-2419 SVST(M MAIAFAC TVRER R(PORTA(XE TO M%05 R(PORTA(LE TO I@ROE SVPtLEM(NTALR(to(IT Ext(CTED IHI YES (ifyes, complete EXPECTED SUBMISSION DATE)

ABSTRACr ()6)

I X I NO EXPECTED SUBMISSION DATE (15)

MON(I(

V(A(I On Thursday, April25, 1996, at 0835, with the plant defueled, two temporary plant electricians inadvertently opened the fused disconnect supplying the Uninterruptible Power Supply (UPS) inverter IN-3 loads, causing a loss of power to the loads.

Deenergization of IN-3 loads resulted in Engineered Safety Feature (ESF) actuations and containment isolations which were reset without further incident by control room personnel.

At the time, the IN-3 loads were being temporarily supplied through a disconnect switch located on Power Panel PP-7A that was labeled as a spare disconnect.

The disconnect handle had a caution tag which identified the disconnect as ON and supplying temporary power to the IN-3 loads.

Also written on the caution tag were instructions to contact the control room prior to operating the disconnect.

The two electricians stated they did not read and understand the caution tag.

They have been restricted from work in the power block for the remainder of the outage, and the importance of the administrative barriers reiterated to maintenance personnel.

Event Notification was made to the NRC pursuant to the requirements of 10 CFR 50.72(b)(2).

~

H

LICENS VENT REPORT (LER) TEXT CO UATION TEXT(l7)

Washington Nuclear Plant Unit 2 05 0

0 0

3 9

7 96 SEOVCNTIAL NUM80l

- 00 1

0 0

2 o"

4 Even Descri tion On Thursday, April 25, 1996, at 0835, with the plant defueled, two temporary plant electricians inadvertently opened the fused disconnect supplying the Uninterruptible Power Supply inverter [UJX,INVT]IN-3 loads, causing a loss of power to the loads.

At the time, the IN-3 loads were being temporarily supplied through a disconnect switch located on Power Panel [PL] PP-7A, and labeled as a spare disconnect.

Deenergization of IN-3 loads resulted in the following ESF actuations:

Start of Control Room Emergency Filtration system Start of Standby Gas Treatment system [BH]

Isolation of Reactor Building Ventilation system [VA]

Isolation of the following containment valves:

~

CSP-V-1 [VB,V]and CEP-V-1A [VB,V](containment purge and exhaust)

~

RCC-V-5 and RCC-V-21 [CC,V] (containment cooling supply and return)

~

EDR-V-395 [V] and FDR-V-220 [V] (reactor building sump discharges to radwaste)

At the time of the incident, the personnel involved were walking down Work Order Task DS34-01 in preparation for replacing the disconnect switch. Their intent was to take photographs of the disconnect fuse clips, and while attempting to open the cabinet door to take the photos they inadvertently opened the disconnect.

Immediate orrective Action Operations restored power to IN-3 loads and reset the ESF actuations without further incident.

Event Notification was made to the NRC pursuant to the requirements of 10 CFR 50.72(b)(2).

The temporary electricians involved were restricted from performing work in the power block.

'I Management expectations concerning equipment cle'arance requirements and the appropriate approvals needed prior to entering panels, components or systems, were reiterated during briefings with plant and contractor maintenance personnel regarding this event.

LICENS VENT REPORT (LER) TEXT CO UATlON TEXT (17)

Washington Nuclear Plant Unit 2 05 0

0 0

3 9

7 96 SKIIIIIHTIAI HVMIOI 0 0 1

0 0

3 o"

4 F rther Evalu i n The two electricians stated they assumed the disconnect was open because the work instructions identified the disconnect as a spare, and the instructions made no mention of the disconnect being the temporary power supply to IN-3. Furthermore, they found the breaker handle in the mid-position between OPEN and CLOSED.

The electricians did not question this condition because the work instructions described the problem as, "cubicle will not close properly and has missing parts.

The main barrier in place to prevent this occurrence was a caution order on the disconnect handle which stated the status as ON.

The back side of the card read, "Caution tag the temporary power supply breaker to PP-7A-A per 10.25.1 step 6.1.14.

Do not operate without CRS/Shift Manager permission."

The electricians stated they failed to notice the status ON indication on the front of the card, and did not read the information on the back of the card.

An additional barrier was provided by direction given in procedure PPM 1.3.7G which specifically disallows opening of panels by craftsmen performing walkdown of work instructions.

Root ause The primary root cause of this event was personnel error.

The electricians involved did not read and follow the instructions on the caution tag.

Additionally, the electricians did not follow the requirements of PPM 1.3.7G which specifically disallows opening of panels by craftsmen performing walkdown of work instructions.

Contributing causes

were lack of a questioning attitude and inexperience using Supply System procedures.

Further orrective Ac i n Revise PPM 10.25.1 to include the requirement to provide field identification of spare disconnects which are providing temporary power.

Revise applicable maintenance lesson plans regarding clearance orders (PPM 1.3.8) and opening of panels by maintenance personnel (PPM 1.3.7G) to include lessons learned from this event.

As e ment of Safe ns uence The safety consequences of this event are minimal because the plant was defueled in Mode 5. All expected actuations and isolations occurred, and the affected systems were restored by control

'oom personnel without further incident.

LICENS VENT REPORT (LER) TEXT CO, UATION TEXT u7)

Washington Nuclear Plant Unit 2 05 0

0 0

3 9

7 96 0 0 1

0 0

4 o"

4 Previous imilar Events Previous LERs documenting personnel error resulting in ESF or RPS actuation are as follows:

~

LER 95-002 involved Operations personnel operating the wrong lever during a main turbine test resulting in turbine trip and reactor scram.

~

LER 93-024 involved personnel error and failure to self check during restoration of the Containment Instrument Air (CIA) system.

Improper restoration resulted in actuation of the CIA backup nitrogen bottle programmer.

~

LER 93-002-01 involved painters inadvertently actuating Reactor Feedwater Pump Room "A" fire protection deluge system which ultimately led to the trip of Reactor Feedwater Pump "A" trip and reactor scram.