| | | Reporting criterion |
|---|
| 05000395/LER-1983-001-01, /01T-0:on 830119,w/plant in Mode 1,three Refueling Water Storage Tank Level Transmitters Failed High. Caused by Frozen Instrument Lines.Transmitters Thawed. Insulated Encls Will Be Installed | /01T-0:on 830119,w/plant in Mode 1,three Refueling Water Storage Tank Level Transmitters Failed High. Caused by Frozen Instrument Lines.Transmitters Thawed. Insulated Encls Will Be Installed | |
| 05000395/LER-1983-001, Updated LER 83-001/01T-1:on 830119,three Refueling Water Storage Tank Level Transmitters Failed High.Caused by Transmitter Base Freezing.Transmitters Thawed.Insulated Encls & Addl Permanent Heat Trace Will Be Installed | Updated LER 83-001/01T-1:on 830119,three Refueling Water Storage Tank Level Transmitters Failed High.Caused by Transmitter Base Freezing.Transmitters Thawed.Insulated Encls & Addl Permanent Heat Trace Will Be Installed | |
| 05000395/LER-1983-003, Forwards LER 83-003/03L-0.Detailed Event Analysis Encl | Forwards LER 83-003/03L-0.Detailed Event Analysis Encl | |
| 05000395/LER-1983-003-03, /03L-0:on 830108 & 20,main Control Board Indication for Steam Generator a Feedwater Flow IFI-477 Failed Low.Caused by High Instrument Cabinet Temp.Power Supply Card Replaced & Recalibr | /03L-0:on 830108 & 20,main Control Board Indication for Steam Generator a Feedwater Flow IFI-477 Failed Low.Caused by High Instrument Cabinet Temp.Power Supply Card Replaced & Recalibr | |
| 05000395/LER-1983-008-03, W/Plant in Mode 1,main Control Board Indication for Steam Generator B Steam Pressure Decreased Approx 100 Psig.Caused by Plugged Transmitter Sensing Line.Sensing Line Back Flushed | W/Plant in Mode 1,main Control Board Indication for Steam Generator B Steam Pressure Decreased Approx 100 Psig.Caused by Plugged Transmitter Sensing Line.Sensing Line Back Flushed | |
| 05000395/LER-1983-008, Forwards Updated LER 83-008/03L-1.Detailed Event Analysis Encl | Forwards Updated LER 83-008/03L-1.Detailed Event Analysis Encl | |
| 05000395/LER-1983-009, Forwards LER 83-009/03L-0.Detailed Event Analysis Encl | Forwards LER 83-009/03L-0.Detailed Event Analysis Encl | |
| 05000395/LER-1983-009-03, /03L-0:on 830203,main Control Board Indicator (PI-950) for Reactor Bldg Pressure Failed Low.Caused by Intermittent Pressure Transmitter Failure.Transmitter Output Returned to Normal | /03L-0:on 830203,main Control Board Indicator (PI-950) for Reactor Bldg Pressure Failed Low.Caused by Intermittent Pressure Transmitter Failure.Transmitter Output Returned to Normal | |
| 05000395/LER-1983-010, Forwards LER 83-010/03L-0.Detailed Event Analysis Encl | Forwards LER 83-010/03L-0.Detailed Event Analysis Encl | |
| 05000395/LER-1983-010-03, /03L-0:on 830206,only One Isotopic Iodine Analysis Performed During Power Reduction from 50% to 5%.Caused by Personnel Misinterpreting Power Changes.Chemistry Lab Policy Issued Re Need for Analysis | /03L-0:on 830206,only One Isotopic Iodine Analysis Performed During Power Reduction from 50% to 5%.Caused by Personnel Misinterpreting Power Changes.Chemistry Lab Policy Issued Re Need for Analysis | |
| 05000395/LER-1983-011, Forwards LER 83-011/03L-0.Detailed Event Analyis Encl | Forwards LER 83-011/03L-0.Detailed Event Analyis Encl | |
| 05000395/LER-1983-011-03, /03L-0:on 830208 & 17,during Mode 1 Operation, Nuclear Sampling Sys Valves 9398 A,B & C Failed to Close. Caused by Limit Switch Failure on One Valve & Crud Buildup on Other Valve Seats.Crud Dislodged.Limit Switches Repaired | /03L-0:on 830208 & 17,during Mode 1 Operation, Nuclear Sampling Sys Valves 9398 A,B & C Failed to Close. Caused by Limit Switch Failure on One Valve & Crud Buildup on Other Valve Seats.Crud Dislodged.Limit Switches Repaired | |
| 05000395/LER-1983-012, Forwards LER 83-012/03L-0.Detailed Event Analysis Encl | Forwards LER 83-012/03L-0.Detailed Event Analysis Encl | |
| 05000395/LER-1983-012-03, /03L-0:on 830210,flow Indicator for Steam Generator a Feedwater Flow FI-477 Failed Low.Caused by Failure of Power Supply FQY-477.Circuit Board Replaced | /03L-0:on 830210,flow Indicator for Steam Generator a Feedwater Flow FI-477 Failed Low.Caused by Failure of Power Supply FQY-477.Circuit Board Replaced | |
| 05000395/LER-1983-013, Forwards LER 83-013/03L-0.Detailed Event Analysis Encl | Forwards LER 83-013/03L-0.Detailed Event Analysis Encl | |
| 05000395/LER-1983-013-03, /03L-0:on 830113 & 19,condensate Storage Tank Level Transmitters LT-3631 & LT-3631A Failed Due to Frozen Instrument Lines.Caused by Temp Sensing Element Not Being Located Per Design Specs.Element Relocated | /03L-0:on 830113 & 19,condensate Storage Tank Level Transmitters LT-3631 & LT-3631A Failed Due to Frozen Instrument Lines.Caused by Temp Sensing Element Not Being Located Per Design Specs.Element Relocated | |
| 05000395/LER-1983-014-03, /03L-0:on 830217 & 0303,pressurizer PORV PCV-445B Found Leaking.Events Discovered by High Temp Indication in PORV Discharge Piping.Cause Unknown.Valve Will Remain Closed & Be Disassembled During 830317 Outage | /03L-0:on 830217 & 0303,pressurizer PORV PCV-445B Found Leaking.Events Discovered by High Temp Indication in PORV Discharge Piping.Cause Unknown.Valve Will Remain Closed & Be Disassembled During 830317 Outage | |
| 05000395/LER-1983-014, Forwards LER 83-014/03L-0.Detailed Event Analysis Encl | Forwards LER 83-014/03L-0.Detailed Event Analysis Encl | |
| 05000395/LER-1983-015-03, /03L-0:on 830219,while in Mode 1,5% Discrepancy Observed Between Main Control Board & Control Room Evacuation Panel Indication for Pressurizer Relief Tank Level.Caused by Design Error.New Transmitter Installed | /03L-0:on 830219,while in Mode 1,5% Discrepancy Observed Between Main Control Board & Control Room Evacuation Panel Indication for Pressurizer Relief Tank Level.Caused by Design Error.New Transmitter Installed | |
| 05000395/LER-1983-015, Forwards LER 83-015/03L-0.Detailed Event Analysis Encl | Forwards LER 83-015/03L-0.Detailed Event Analysis Encl | |
| 05000395/LER-1983-016, Forwards LER 83-016/03L-0.Detailed Event Analysis Encl | Forwards LER 83-016/03L-0.Detailed Event Analysis Encl | |
| 05000395/LER-1983-016-03, /03L-0:on 830216,w/plant in Mode 1,discrepancy of 6% Observed Between Main Control Board Indicators for Sodium Hydroxide Storage Tank Level.Caused by Loose Fitting on High Side Sensing Line of Level Transmitter | /03L-0:on 830216,w/plant in Mode 1,discrepancy of 6% Observed Between Main Control Board Indicators for Sodium Hydroxide Storage Tank Level.Caused by Loose Fitting on High Side Sensing Line of Level Transmitter | |
| 05000395/LER-1983-017, Forwards LER 83-017/03L-0.Detailed Event Analysis Encl | Forwards LER 83-017/03L-0.Detailed Event Analysis Encl | |
| 05000395/LER-1983-017-03, /03L-0:on 830305,remote Info Acquisition Cabinet Experienced Electronic Problems Rendering Four Reactor Bldg Zone 3 Smoke Detectors Inoperable.Caused by Printed Circuit Card Failure.Card Replaced | /03L-0:on 830305,remote Info Acquisition Cabinet Experienced Electronic Problems Rendering Four Reactor Bldg Zone 3 Smoke Detectors Inoperable.Caused by Printed Circuit Card Failure.Card Replaced | |
| 05000395/LER-1983-018-03, /03L-0:on 830306,while in Mode 1,nuclear Sampling Sys Valves 9398 A,B & C Failed to Close During Initial Performance of Accelerated Test Program.Caused by Crud Buildup on Valve Seats.Crud Dislodged & Switch Repaired | /03L-0:on 830306,while in Mode 1,nuclear Sampling Sys Valves 9398 A,B & C Failed to Close During Initial Performance of Accelerated Test Program.Caused by Crud Buildup on Valve Seats.Crud Dislodged & Switch Repaired | |
| 05000395/LER-1983-018, Forwards LER 83-018/03L-0.Detailed Event Analysis Encl | Forwards LER 83-018/03L-0.Detailed Event Analysis Encl | |
| 05000395/LER-1983-019-01, /01L-0:on 830317,trains of RHR & High Head Safety Injection Train a Inoperable for Approx 45 Minutes.Caused by Switching Problems W/Starting Circuitry of Chiller Unit XHX0001C.Switch Apparatus Modified | /01L-0:on 830317,trains of RHR & High Head Safety Injection Train a Inoperable for Approx 45 Minutes.Caused by Switching Problems W/Starting Circuitry of Chiller Unit XHX0001C.Switch Apparatus Modified | |
| 05000395/LER-1983-019, Forwards LER 83-019/01L-0.Detailed Event Analysis Encl | Forwards LER 83-019/01L-0.Detailed Event Analysis Encl | |
| 05000395/LER-1983-020-03, /03L-0:on 830305,fire Detector Sys Control Room Alarm Capability Lost for Intermediate Bldg Zones Aa,Bb & CC & for Diesel Generator Bldg Zones DG (427) & DG (436).Caused by Blown Fuse.Fuse Replaced | /03L-0:on 830305,fire Detector Sys Control Room Alarm Capability Lost for Intermediate Bldg Zones Aa,Bb & CC & for Diesel Generator Bldg Zones DG (427) & DG (436).Caused by Blown Fuse.Fuse Replaced | |
| 05000395/LER-1983-020, Forwards LER 83-020/03L-0.Detailed Event Analysis Encl | Forwards LER 83-020/03L-0.Detailed Event Analysis Encl | |
| 05000395/LER-1983-021, Forwards LER 83-021/03L-0.Detailed Event Analysis Encl | Forwards LER 83-021/03L-0.Detailed Event Analysis Encl | |
| 05000395/LER-1983-021-03, /03L-0:on 830307,steam Generator Blowdown Monitor RM-L3 Failed Low,Reducing Number of Operable Channels. Caused by Moisture in Monitor Detector Due to Overhead Sample Valve O-ring Rupture.Detector Replaced | /03L-0:on 830307,steam Generator Blowdown Monitor RM-L3 Failed Low,Reducing Number of Operable Channels. Caused by Moisture in Monitor Detector Due to Overhead Sample Valve O-ring Rupture.Detector Replaced | |
| 05000395/LER-1983-022-03, /03L-0:on 830308,conduit Containing Smoke Detector Circuits Cut During Core Drilling for Plant Mod.Fire Watch Posted.Caused by Failure to See Conduit Embedded in Fireproofing Matl.Conduit & Cable Replaced | /03L-0:on 830308,conduit Containing Smoke Detector Circuits Cut During Core Drilling for Plant Mod.Fire Watch Posted.Caused by Failure to See Conduit Embedded in Fireproofing Matl.Conduit & Cable Replaced | |
| 05000395/LER-1983-022, Forwards LER 83-022/03L-0.Detailed Event Analysis Encl | Forwards LER 83-022/03L-0.Detailed Event Analysis Encl | |
| 05000395/LER-1983-023, Forwards LER 83-023/03L-0.Detailed Event Analysis Encl | Forwards LER 83-023/03L-0.Detailed Event Analysis Encl | |
| 05000395/LER-1983-023-03, /03L-0:on 830309,main Control Board Pressure Indicator for Reactor Bldg Pressure Channel 950 Failed Low. Caused by Intermittent Electronic Failure of Transmitter. Transmitter Replaced | /03L-0:on 830309,main Control Board Pressure Indicator for Reactor Bldg Pressure Channel 950 Failed Low. Caused by Intermittent Electronic Failure of Transmitter. Transmitter Replaced | |
| 05000395/LER-1983-024, Forwards LER 83-024/03L-0.Detailed Event Analysis Encl | Forwards LER 83-024/03L-0.Detailed Event Analysis Encl | |
| 05000395/LER-1983-024-03, /03L-0:on 830311,main Steam Line C Radiation Monitor Experienced Spurious Alarms.Caused by Slack Detector Cable Allowing Signal Oscillations.Detector Cable Will Be More Adequately Secured by 830501 | /03L-0:on 830311,main Steam Line C Radiation Monitor Experienced Spurious Alarms.Caused by Slack Detector Cable Allowing Signal Oscillations.Detector Cable Will Be More Adequately Secured by 830501 | |
| 05000395/LER-1983-025, Forwards LER 83-025/03L-0.Detailed Event Analysis Encl | Forwards LER 83-025/03L-0.Detailed Event Analysis Encl | |
| 05000395/LER-1983-025-03, /03L-0:on 830313,containment Bulkhead Door Seal on Personnel Access Air Lock Found W/Excessive Seal Leakage. Caused by Dirt on Door Seal.Seal Cleaned.Air Lock Tested | /03L-0:on 830313,containment Bulkhead Door Seal on Personnel Access Air Lock Found W/Excessive Seal Leakage. Caused by Dirt on Door Seal.Seal Cleaned.Air Lock Tested | |
| 05000395/LER-1983-026, Forwards LER 83-026/03L-0 | Forwards LER 83-026/03L-0 | |
| 05000395/LER-1983-026-03, /03L-0:on 830318,reactor Bldg Cooling Unit Svc Water Flow Indicators Failed Low & Accident Monitoring Instrumentation Channel 4496 Declared Inoperable.Caused by Internal Failure of Indicator FI-4496.Indicator Replaced | /03L-0:on 830318,reactor Bldg Cooling Unit Svc Water Flow Indicators Failed Low & Accident Monitoring Instrumentation Channel 4496 Declared Inoperable.Caused by Internal Failure of Indicator FI-4496.Indicator Replaced | |
| 05000395/LER-1983-027, Forwards LER 83-027/03L-0.Detailed Event Analysis Encl | Forwards LER 83-027/03L-0.Detailed Event Analysis Encl | |
| 05000395/LER-1983-027-03, /03L-0:on 830318,main Control Board Temp Indication TE-413 for Reactor Coolant Outlet Temp Exhibited Erratic Indications.Caused by Varying Resistance Between Compensated Lead & Low Side Resistance Leg of TE-413 | /03L-0:on 830318,main Control Board Temp Indication TE-413 for Reactor Coolant Outlet Temp Exhibited Erratic Indications.Caused by Varying Resistance Between Compensated Lead & Low Side Resistance Leg of TE-413 | |
| 05000395/LER-1983-028-01, /01T-0:on 830406,out-of-tolerance Measurement Found on Undervoltage (UV) Trip Device Between Moving Core & Rolling Bracket.Caused by Mfg Variation of UV Trip Devices. Devices Will Be Replaced | /01T-0:on 830406,out-of-tolerance Measurement Found on Undervoltage (UV) Trip Device Between Moving Core & Rolling Bracket.Caused by Mfg Variation of UV Trip Devices. Devices Will Be Replaced | |
| 05000395/LER-1983-028, Forwards LER 83-028/01T-0.Detailed Event Analysis Encl | Forwards LER 83-028/01T-0.Detailed Event Analysis Encl | |
| 05000395/LER-1983-029, Forwards LER 83-029/03L-0.Detailed Event Analysis Encl | Forwards LER 83-029/03L-0.Detailed Event Analysis Encl | |
| 05000395/LER-1983-029-03, /03L-0:on 830320,w/reactor Bldg Purge Initiated, Radiation Monitor RM-A4 Read Higher than Normal Pump RM-A4 & Detector Secured to Change Filter,Leaving Purge Unmonitored for 5 Minutes.No Activity Released During Event | /03L-0:on 830320,w/reactor Bldg Purge Initiated, Radiation Monitor RM-A4 Read Higher than Normal Pump RM-A4 & Detector Secured to Change Filter,Leaving Purge Unmonitored for 5 Minutes.No Activity Released During Event | |
| 05000395/LER-1983-030, Forwards LER 83-030/03L-0.Detailed Event Analysis Encl | Forwards LER 83-030/03L-0.Detailed Event Analysis Encl | |
| 05000395/LER-1983-030-03, /03L-0:on 830324,reactor Bldg Fire Detection Zones Ooo & Ppp Declared Inoperable When Power Supply Breaker Opened.Caused by Faulty Power Supply Transformer in Smoke Detector IXA-4964E in Zone Ppp.Transformer Replaced | /03L-0:on 830324,reactor Bldg Fire Detection Zones Ooo & Ppp Declared Inoperable When Power Supply Breaker Opened.Caused by Faulty Power Supply Transformer in Smoke Detector IXA-4964E in Zone Ppp.Transformer Replaced | |