05000361/LER-2002-002
Docket Number | |
Event date: | 02-08-2002 |
---|---|
Report date: | 05-09-2002 |
Reporting criterion: | 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications |
3612002002R00 - NRC Website | |
LER NUMBER FACILITY MANE()) DOCKET (3) PAGE (3) — 002 — I 00 2002 FV9253 is required to close on a manual SIAS to isolate the VCT. In Modes 5 and 6, either FV9253 or the combination of HV9257 and FV0210Y are required to be closed to isolate the VCT.
Description of the Event:
In January 2002, SCE was performing the Emergency Operating Instructions (E01s) biannual review.
During this review, SCE decided to proceduralize use of FV9253 instead of FV0210Y for isolating the VCT for the "Train A" Emergency Boric Acid flow path {CB} (See Figure 1 and the Additional Information section below). An Action Request (AR 020101598) was generated to change the abnormal operating instruction (A01) to match the changes to the EOls.
On February 7, 2002, during the review and approval of the A01 (S023-13-11) and the Boric Acid flow path surveillance procedure (S023-3-3.1), SCE recognized that the Boric Acid flow path surveillance procedure would also require revision to match the E01 and A01. On February 8, 2002, AR 020200426 was opened noting FV9253 was not included in the SR procedure. Subsequently, on March 12, 2002 (discovery date), SCE recognized that the Bases for SR 3.1.9.3 and 3.1.9.4 (to isolate the VCT in the response to an actual or simulated SIAS) require FV9253 or the combination of HV9257 and FV0210Y to be closed to preclude an emergency boric acid flow path diversion. This would require valve FV9253 or the combination of HV9257 and FV0210Y to be included in the 31- day SR 3.1.9.3 and SR 3.1.10.4 for the "Train A" flow path (procedure S023-3-3.1). Note that the surveillance testing to comply with SR 3.1.9.4 (24 month SR) had correctly included FV9253 (procedure S023-3-3.12).
While completing the corrective actions discussed below, SCE discovered that other manually operated valves had been omitted from other similar flow path verification procedures and were not locked seated or otherwise secured in position (see Figures 2 and 3 and the Additional Information section below):
System Tech Spec SR Procedures Valves not in SR Procedure Auxiliary Feedwater (AFW) 3.7.5.1 S023-3-3.16 MU047, MU052, MU087, MU057, MU055 Component Cooling Water (CCW) 3.7.7.2 S023-3-3.18 & S023-3-3.27 MU732, MU733, & Backup Nitrogen bottle block valves Because these valves {ISV} were not included in the applicable SR procedures, SCE is reporting these occurrences in accordance with 10CFR50.73(a)(2)(i)(B) as a condition prohibited by the plant's TS.
Cause of the Event:
As originally drafted (11/21/80), the Boric Acid Flow Path surveillance procedure did include valves FV0210Y, HV9257, and FV9253. Shortly before issuance of the Unit 2 low power license (2/19/82), they were removed from the procedure. Due to the passage of time, SCE did not determine why the valves were removed from the procedure.
LER NUMBER 6 DOCKET (2) FACILITY NAAE(1) PAGE (31._ — 002 — I 00 12002 SCE has not yet determined why the AFW {BA} and CCW {CC} system valves were not included in the appropriate procedures. SCE will document the results of this cause evaluation in our corrective actions program.
Corrective Actions:
- On February 8, 2002, the Monthly Boric Acid Flow Path surveillance procedure was revised to require verification of VCT isolation valve FV9253 during Modes 1 through 4.
- The Boric Acid Flow Path surveillance procedure will be revised to require verification of the valve(s) that isolate VCT when the BAMU "Train A" flow path is used during Modes 5 and 6.
- The Bases to SR 3.1.10.4 will be revised to remove the requirements for automatic VCT isolation from a SIAS.
- The Component Cooling Water (CCW) surveillance procedure will be updated to include valves MU732, MU733 and the nitrogen bottles block valves in the back-up nitrogen supply line to the CCW surge tank.
- A review of other ESF flow path surveillance's (Emergency Core Cooling System, Containment Spray System, AFW System, CCW System) will be conducted to ensure the associated surveillance procedures includes all TS required components for each flow path.
- Manual valves MU047, MU052, MU087, MU057 and MU055 from the Auxiliary Feedwater System minimum flow line to the Chemical Feed will be added to the locked valve program.
Safety Significance:
Boric Acid System: The omission of valve FV9253 in the surveillance procedure would not have prevented plant operators from borating the RCS when needed. Valve FV9253 is exercised several times daily to provide primary water addition and blending to reduce the boron concentration in the VCT and ultimately the RCS. Operation of FV9253 is controlled in accordance with procedure S023-3-2.2, "Makeup Operations." Closure indication for FV9253 is confirmed following manipulation and additionally checked twice per shift during control board walkdown as part of the turnover process. This shiftly confirmation of valve position is much more frequent than the 31-day frequency specified by SR 3.1.9.3. The ability of the valve to isolate in response to SIAS was being correctly verified in accordance with SR 3.3.6.2.
Auxiliary Feedwater System: SCE does not manipulate valves MU047, MU052, MU087, MU057 and MU055 during plant operation. Instead, these valves are used for chemical additions performed during outages. Valve position verification is independently performed in accordance with procedure S0123-III-2.12.23. Additionally, the Action Request System (MOSAIC) had no occurrences of mispositioning of these valves.
Component Cooling Water: Although not being surveilled, closure of either of the common nitrogen manual valves (MU732 or MU733) would cause low surge tank pressure which would be noted by operations personnel during the shiftly rounds and which would alarm in the control room. Therefore, misposition of either valve would be self-revealing. Nitrogen bottle block valve positions are independently verified to be open during CCW check valve testing during refueling outages (procedure S023-3-31.3). Daily operator rounds and weekly surveillance's on the backup nitrogen system verify that the system pressure is within FACL/TY NANE(1) ) DOCKET (2) LER NUMBER (6) PAGE (3) 2002 —002- 00 the required limits. The individual block valves are opened and closed when a nitrogen bottle is replaced.
Additionally, the Action Request System (MOSAIC) had no occurrences of mispositioning of these valves.
Therefore, omission of these valves from the applicable surveillance procedures had no safety significance.
SCE also evaluated this occurrence using the NRC's current Significant Determination Process as documented in MC0609 and 0612, Appendix E Examples 4.12 and 4.13. The occurrence was determined to be an "insignificant procedural error" not affecting operability since, as described above, there were no mispositioned valves within the last three years and consequently is below the significance of that associated with green SDP findings.
Additional Information:
Auxiliary Feedwater System:
The AFW System consists of two motors driven AFW pumps and one steam turbine driven pump configured into three trains. Each motor driven pump provides 100% of AFW flow capacity; the turbine driven pump provides 100% of the required capacity to the steam generators as assumed in the accident analysis. The pumps are equipped with independent recirculation lines to prevent pump operation against a closed system.
A minimum flow line tapped from the recirculation line of each Auxiliary Feedwater Pump is used to pass condensate through chemical feeder W-011 of the Auxiliary Feedwater Chemical Addition System. The chemical feeder is put into service to batch feed solutions of hydrazine and ammonia when the Auxiliary Feedwater Chemical Addition System is manually operated. After passing through the chemical feeder, the condensate flow is re-injected further downstream into each auxiliary feedwater line. Valves MU047, MU052, MU087, MU057, and MU055 are manually operated valves in the Auxiliary Feedwater pump miniflow lines which are maintained closed to prevent the diversion of Aux Feedwater flow.
Component Cooling Water System:
The CCW System provides a heat sink for the removal of process and operating heat from safety related components during a Design Basis Accident (DBA) or transient. The Backup Nitrogen Supply (BNS) system is an independent, safety related, Seismic Category I source of pressurized nitrogen to prevent high-point voiding by maintaining the CCW critical loops water-solid during Design Basis Event mitigation.
BNS system OPERABILITY ensures that both CCW surge tanks will be pressurized for at least seven days following a Design Basis Event without bottle changeout or Operator action (post accident high radiation area). The BNS system is required to be OPERABLE whenever the associated train of CCW is required to be OPERABLE.
The bases for TS SR 3.7.7.2 states that verification of the correct alignment for manual, power operated, and automatic valves in the CCW flow path is required to provide assurance that the proper flow paths exist for CCW operation. While the BNS system valves are not in the direct CCW flow path, BNS system Operability is a requirement for CCW system Operability. Therefore, BNS valve positions should be verified as part of the 31 day CCW flowpath verification surveillance.
DOCKET (2) PAGE (3)_ FACILITY NAME()) LER NUMBER BD_
Previous Similar Events:
- On November 2, 2000, LER 2-2000-012 reported that closing 2HV9200 in Mode 4 during the cycle 10 refueling outage may not have maintained the two boration flow paths required by TS 3.1.9. That LER concerned application of the Limiting Condition for Operation (LCO) itself and corrective actions were focused on the LCO requirements relative to HV9200. The event reported herein concerns performance of the associated SRs. Therefore, corrective actions for LER 2-2000-012 could not have prevented this event.
- On June 23, 2000, SCE reported an occurrence involving verbatim application of TS Bases to the performance of a TS SR. The Bases to SR 3.6.6.1.1 noted the requirement of verification of valve position, "through a system walk-down." However, the methods of verification in the procedure (S0123-0-23.1) allowed verification of valve position by a control board indicator walk-down. This condition does not involve the same underlying concern or reason as this event and the corrective actions taken could not have prevented the event reported herein.
- There were two previous opportunities for SCE to recognize the issue reported herein:
On October 15, 1984, (revision 8) the VCT Outlet Valve, LV0227B was added to the surveillance procedure with a note that required it to be closed for Boric Acid Injection via the gravity feed flow paths. Operator training for this system indicates that if LV0227B is not closed, the VCT overpressure would backseat "Train B" (gravity feed) check valve (MU082) which would prevent "Train B" from supplying boric acid to the RCS.
During the implementation of the TSIP SRs, SCE identified several reportable conditions pertaining to the new surveillance requirements (see LER 2-1997-001, Rev. 3, "Surveillances Not Current Upon Improved Technical Specification Implementation"). Corrective actions associated with the reported events included a TS Self Assessment that reviewed each TS SR to verify that both the current surveillance procedure and the current test of record met, verbatim, the TS requirements.
It appears that this review also did not recognize that the automatic or manual isolation of the VCT for a "Train A' Boric Acid flow path required additional valves to be verified.
FACSLITY NAME()) LER NUMBER (A) PAGE (3) 05000-361
- 2002 — 002 — 00 a) DOCKET U.S. NUCLEAR REGULATORY COMMISSION Figure 1 n 4 e.) 0
CI
0 Go 1111Ampari I I t41 1 - 'n " A" B ora tio n C5 O
CO
cip ) Itramilur a. .4D a., FACILITY woman DOCKET 121 San Onofre Nuclear Generating Station (SONGS) Unit 2 [05000-361 Figure 2 — Aux Feedwater System (Part) zw keg S 5 I exeri-../c Ewe 505 cif -(03>1 cell -0)0%3 12 14041-11 (R/c-1- 70-..1/C fief l 5.6c
SW
SOCA
LER NUMBER 6) —002 — I 00 2002 ( t,.-o-ri-. ) .
04 II ›.- (nip-W) Ir-Fr
- C *4 ;D. 41A r, 1 //' 4 3 I II I .C115 4 d 0 lit
- 1 ,0.t" 91C1/
- tEC DG 01.2 ( ) 11411Z LIC
- 10,4— [MU 73 3 is loc ate d o n Tr ain A (no t S ho wn )] A a+, U.S. NUCLEAR REGULATORY COMMISSION DOCKET (2) LER NUMBER (6) PAGE (3) FACILITY NAMED) San Onofre Nuclear Generating Station (SONGS) Unit 2 05000-361 2002 — 002 — 00 Figure 3a - CCW System (Part) FACILITY NAME(1) PAGE 131 DOCKET rn I LER NUMBER 6) Figure 3b - CCW System (Part)