05000306/LER-1998-002, Forwards LER 98-002-01,re Defect in Primary Sys Pressure Boundary Observed on Motor Tube Base of Part Length CRDM Housing.Commitments Made within Ltr,Encl

From kanterella
(Redirected from 05000306/LER-1998-002)
Jump to navigation Jump to search
Forwards LER 98-002-01,re Defect in Primary Sys Pressure Boundary Observed on Motor Tube Base of Part Length CRDM Housing.Commitments Made within Ltr,Encl
ML20247R188
Person / Time
Site: Prairie Island Xcel Energy icon.png
Issue date: 05/22/1998
From: Sorensen J
NORTHERN STATES POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20247R194 List:
References
NUDOCS 9805290088
Download: ML20247R188 (2)


LER-2098-002, Forwards LER 98-002-01,re Defect in Primary Sys Pressure Boundary Observed on Motor Tube Base of Part Length CRDM Housing.Commitments Made within Ltr,Encl
Event date:
Report date:
3062098002R00 - NRC Website

text

~

Northern States Power Company Prairie Island Nuclear Generating Plant 1717 Wakonade Dr. East Welch, Minnesota 55089 May 22,1998 10 CFR Part 50 Section 50.73 U S Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 PRAIRIE (SLAND NUCLEAR GENERATING PLANT Docket Nos. 50-282 License Nos. DPR-42 50-306 DPR-6u LER 2-98-02, Supplement 1 Defect in Prii.1ary System Pressure Boundary Observed on the Motor Tube Base of Part Length CRDM Housing The revised Licensee Event Report for this occurrence is attached. In the original LER submittal we committed to provide a supplement to the subject LER by April 13,1998.

By letter dated April 6,1998, we indicated the supplement to the LER would be delayed to May 22,1998 to be able to incorporate the information from tha formal root cause analysis being prepared by Westinghouse. The Westinghouse root cauce analysis (WCAP - 15054) was submitted to the NRC on May 15,1998.

In the report, we reiterated two NRC commitments (made with the original issuance of this LER on March 2,1993), indicated as the Corrective Action statement in italics.

Please contact us if you require additional information related to this event.

Joel P Sorensen \j Plant Manager Prairie Island Nuclear Generating Plant ny 1

f b ~,

l 9805290088 980522 PDR ADOCK 05000306 S PDR i

L-------_------------------------_----

. NORTHERN STATES POWER COMPANY

$Nf22 1998 Page 2

-f

-i c: Regional Administrator- Region Ill, NRC NRR Project Manager, NRC Senior Resident inspector, NRC Kris Sanda, State of Minnesota  !

Attachment C