Finding | |
---|---|
Title | Failure to Establish Procedures to Verify RHR is Full of Water Following Maintenance Outages |
Description | A finding of very low safety significance (Green), and an associated NCV of 10 CFR Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, was self-revealed for the licensees failure to establish procedures to verify RHR is operable with respect to gas accumulation following maintenance outages. Specifically, procedures were not established to verify the system is sufficiently full of water when RHR is secured in its standby emergency core cooling system mode of operation during startup activities following maintenance outages. The licensee captured this issue into their CAP. As a long term corrective action, the licensee revised procedures to require gas accumulation inspections of the affected gas susceptible locations as part of the unit startup activities following a maintenance outage. The performance deficiency was determined to be more than minor because it was associated with the Mitigating Systems cornerstone attribute of equipment performance, and affected the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. The finding screened as of very low safety significance (Green) because it did not result in the loss of operability or functionality of mitigating systems. Specifically, the licensee performed a past operability review of the limiting void found at the RHR piping after maintenance outages and reasonably concluded that the system remained operable. The inspectors did not identify a cross-cutting aspect associated with this finding because it was not confirmed to reflect current performance. |
Site: | Prairie Island |
---|---|
Report | IR 05000282/2015008 Section 4OA2 |
Date counted | Dec 31, 2015 (2015Q4) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | Self-revealing |
Inspection Procedure: | IP 71152 |
Inspectors (proximate) | C Lipa N Feliz-Adorno |
Violation of: | 10 CFR 50 Appendix B Criterion V |
INPO aspect | |
' | |
Finding - Prairie Island - IR 05000282/2015008 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Prairie Island) @ 2015Q4
Self-Identified List (Prairie Island)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||