Finding | |
|---|---|
| Title | Failure to Manage Gas Accumulation at the RHR Train Credited for Emergency Core Cooling in MODE 4 |
| Description | The inspectors identified a finding of very low safety significance (Green), and an associated NCV of 10 CFR Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, for the licensees failure to manage gas accumulation at the residual heat removal (RHR) train credited for emergency core cooling in MODE 4, Hot Shutdown. Specifically, the RHR train credited for emergency core cooling in MODE 4 was not verified to be full of water before its operability was required in MODE 4 following system draining during refueling outage 1R29. The licensee captured this issue into their CAP with a proposed corrective action to revise procedures to explicitly require these inspections prior to transitioning into MODE 4 during startup activities
The performance deficiency was determined to be more than minor because it was associated with the Mitigating Systems cornerstone attribute of equipment performance, and affected the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. The finding screened as of very low safety significance (Green) because it did not result in the loss of operability or functionality of mitigating systems. Specifically, the licensee reviewed records associated with gas accumulation management activities during 1R29 and discovered that a non-conforming void was vented 12 18 hours2.083333e-4 days <br />0.005 hours <br />2.97619e-5 weeks <br />6.849e-6 months <br /> after the transition to MODE 4. However, an operability review reasonably determined that this non-conforming condition did not result in loss of operability. The inspectors did not identify a cross-cutting aspect associated with this finding because it was not confirmed to reflect current performance. |
| Site: | Prairie Island |
|---|---|
| Report | IR 05000282/2015008 Section 4OA2 |
| Date counted | Dec 31, 2015 (2015Q4) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71152 |
| Inspectors (proximate) | C Lipa N Feliz-Adorno |
| Violation of: | 10 CFR 50 Appendix B Criterion V |