05000306/FIN-2015008-01
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | |
| Description | The inspectors identified a finding of very low safety significance (Green), and an associated cited violation of Title 10, Code of Federal Regulations (CFR), Part 50, Appendix B, Criterion XVI, Corrective Actions, for the failure to correct a condition adverse to quality (CAQ). Specifically, on August 1, 2011, the NRC issued an NCV for the failure to monitor five safety-related gas susceptible locations considered to be inaccessible, which is a CAQ. As of November 24, 2015, the licensee had not corrected this CAQ for two of those locations and did not have plans to restore compliance. The licensee captured this issue into their Corrective Action Program (CAP) with a proposed corrective action to develop an alternative monitoring method for these locations when the unit is operating. The performance deficiency was determined to be more than minor because it was associated with the Mitigating Systems cornerstone attribute of equipment performance, and affected the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. The finding screened as of very low safety significance (Green) because it did not result in the loss of operability or functionality of mitigating systems. Specifically, the licensee was able to access and inspect these locations during the refueling outage that was ongoing when this issue was identified and confirmed that they were full of water during the previous operating cycle. In addition, a historical review did not find information that challenged operability due to gas accumulation at these locations. The inspectors determined that this finding had a cross-cutting aspect in the area of problem identification and resolution because the licensee did not thoroughly evaluate their discovery that the CAQ was not been corrected on July 29, 2013. Specifically, on 2013, the licensee initiated a condition evaluation (CE) to determine if the action plan at the time addressed the NCV associated with the CAQ. However, the CE was closed by crediting actions that were similar to those that resulted in the NCV and other documented observations associated with the inappropriate resolution of the issue. |
| Site: | Prairie Island |
|---|---|
| Report | IR 05000306/2015008 Section 4OA2 |
| Date counted | Dec 31, 2015 (2015Q4) |
| Type: | Violation: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71152 |
| Inspectors (proximate) | C Lipa N Feliz-Adornog Hausmang O'Dwyer J Bozga K Riemer L Haeg M Garza M Jones N Feliz-Adorno P Laflamme P Zurawski R Baker S Bell |
| Violation of: | 10 CFR 50 Appendix B Criterion XVI |
| CCA | P.2, Evaluation |
| INPO aspect | PI.2 |
| ' | |
Finding - Prairie Island - IR 05000306/2015008 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Prairie Island) @ 2015Q4
Self-Identified List (Prairie Island)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||