Core Operating Limits Report (COLR) for Prairie Island Nuclear Generating Plant (PINGP) Unit 2, Cycle 31, Revision 0
ML19296D388
Person / Time
Site: Prairie Island Xcel Energy icon.png
Issue date: 10/23/2019
From: Sharp S
Northern States Power Company, Minnesota, Xcel Energy
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-Pl-19-043
Download: ML19296D388 (35)


Text

Xcel Energy RES P O N S I B LE B V NAT UR E 1717 Wakonade Drive Welch, MN 55089 October 23, 2019 L-Pl-19-043 TS 5.6.5.d ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Prairie Island Nuclear Generating Plant Unit 2 Docket No. 50-306 Renewed Facility Operating License No. DPR-60 Core Operating Limits Report (COLR) for Prairie Island Nuclear Generating Plant (PINGP)

Unit 2, Cycle 31, Revision 0 Pursuant to the requirements of Technical Specification 5.6.5.d, Northern States Power Company, a Minnesota Corporation (NSPM), doing business as Xcel Energy, hereby submits the COLR for the PINGP Unit 2, Cycle 31, Revision 0. The COLR provides the cycle-specific values of the limits established using NRG approved methodologies such that the applicable limits of the plant safety analysis are met.

The COLR for PINGP Unit 2 Cycle 31, Revision 0, is provided in Enclosure 1.

Summary of Commitments This letter contains no new commitments and no revisions to existing commitments .

.fa~

Scott Sharp Site Vice President, Prairie Island Nuclear Generating Plant Northern States Power Company - Minnesota Enclosure cc: Administrator, Region Ill, USNRC Project Manager, Prairie Island, USNRC Resident Inspector, Prairie Island, USNRC State of Minnesota

Document Control Desk Page 2 ENCLOSURE 1 PRAIRIE ISLAND NUCLEAR GENERATING PLANT CORE OPERATING LIMITS REPORT UNIT 2 - CYCLE 31 REVISION 0 Unit 2 - Cycle 31, Revision 0 (33 pages)

PRAIRIE ISLAND NUCLEAR GENERATING PLANT Core Operating Limits Report Record of Revision Unit Cycle Revision Approval No. Date Remarks 2 13 0 3/22/90 Original Unit 2 Core Operating Limits Report, distributed with Technical Specification Revision 92.

1 14 0 3/22/90 Original Unit 1 Core Operating Limits Report, distributed with Technical Specification Revision 92.

1 7/27/90 Incorporated expanded V(z) curves.

2 9/27/90 Clarified rod insertion limit curve applicability.

3 2/11/91 Incorporated revised FQ of 2.45 as a result of NRC approval of Westinghouse Topical Report WCAP-10924-P-A, Volume 1, Addendum 4, October 1990.

2 14 0 - Not used.

1 9/27/90 Updated to Unit 2 Cycle 14, incorporated expanded V(z) curves and clarified rod insertion limit curve applicability.

2 2/11/91 Incorporated revised FQ of 2.45 as a result of NRC approval of Westinghouse Topical Report WCAP-10924-P-A, Volume 1, Addendum 4, October 1990.

1 15 0 6/25/91 Updated to Unit 1 Cycle 15.

2 15 0 3/9/92 Updated to Unit 2 Cycle 15 and clarified labeling of Figure 4. Clarified the actions to be taken if the nuclear enthalpy rise hot channel factor exceeds the Technical Specification limit.

1 16 0 12/28/92 Updated to Unit 1 Cycle 16, removed V(z) curves and replaced them with list of bounding V(z) values for three ranges of exposures.

2 16 0 12/8/93 Updated to Unit 2 Cycle 16. Removed the multiple V(z) curves and replaced them with a single figure with bounding V(z) curves for four ranges of exposures. Incorporated additional discussion related to V(z) and K(z).

Page 1 of 7

PRAIRIE ISLAND NUCLEAR GENERATING PLANT Core Operating Limits Report Record of Revision Unit Cycle Revision Approval No. Date Remarks 2 16 1 11/3/94 The table containing the bounding V(z) values and Figure 2 updated to incorporate revised bounding V(z) values for the exposure range of 14-21.5 GWD/MTU. Figures 3 through 6 re-formatted.

1 17 0 6/17/94 Updated to Unit 1 Cycle 17. Removed the list of bounding V(z) values and replaced it with multiple V(z) curves. Incorporated additional discussion related to V(z) and K(z).

2 17 0 6/2/95 Updated to Unit 2 Cycle 17. Incorporated Table 1 and expanded Figure 2 with updated bounding V(z) values.

1 18 0 2/7/96 Updated to Unit 1 Cycle 18. Incorporated revised FH limit of 1.77. Incorporated Table 1 and updated Figure 2 with revised bounding V(z) values.

2 18 0 2/27/97 Updated to Unit 2 Cycle 18. Revised FH limit to 1.77. Updated Table 1 and Figures 2a through 2e with revised bounding V(z) values.

Incorporated new Figures 2f and 2g with additional bounding V(z) values.

1 19 0 9/25/97 Updated to Unit 1 Cycle 19. Updated Table 1 and Figures 2a through 2f with revised bounding V(z) values.

2 19 0 12/17/98 Updated to Unit 2 Cycle 19. Updated Table 1 and Figures 2a through 2d with revised bounding V(z) values. Deleted Figures 2e, 2f and 2g.

1 20 0 5/13/99 Updated to Unit 1 Cycle 20. Updated Table 1 and Figures 2a through 2f with revised bounding V(z) values.

1 8/4/00 Technical Specification Amendment 151:

Relocate shutdown margin (SDM) requirements from Tech Specs and incorporate additional SDM requirements for Modes 3-6 from revised analysis of Uncontrolled Dilution event.

Page 2 of 7

PRAIRIE ISLAND NUCLEAR GENERATING PLANT Core Operating Limits Report Record of Revision Unit Cycle Revision Approval No. Date Remarks 2 20 0 5/31/00 Updated to Unit 2 Cycle 20. Updated Table 1 and Figures 2a through 2d with revised bounding V(z) values. Added new Table 2 and Figures 2e, 2f and 2g with additional bounding V(z) values.

Added references to Tables 1 and 2 and to Figures 2e, 2f and 2g to discussion of heat flux hot channel factor limits. Added discussion clarifying applicability of axial flux difference limits when using Tables 1 and 2 and Figures 2a through 2g. Added discussion of two tier V(z) curve presented in Table 2 and Figure 2g.

1 8/4/00 Technical Specification Amendment 142:

Relocate shutdown margin (SDM) requirements from Tech Specs and incorporate additional SDM requirements for Modes 3-6 from revised analysis of Uncontrolled Dilution event.

1 20 2 9/1/00 Revised to change axial flux difference target band.

1 21 0 1/31/01 Updated to support refueling activities associated with Unit 1 Cycle 21. Revision 0 of the Unit 1 Cycle 21 COLR had to be issued prior to confirming the applicability of the LOCA analysis.

Therefore, Revision 0 of the Unit 1 Cycle 21 COLR does not contain all of the operating limits necessary to support operation of Unit 1 Cycle 21.

1 21 1 2/19/01 Updated to Unit 1 Cycle 21. Updated Tables 1 and 2 and Figures 2a through 2f with revised bounding V(z) values.

1 21 2 10/02/02 Revised to support License Amendment 158 changes, including revision of all references to TS, revision of FQ symbols, addition of Table 4, ITC limits, DNB limits and refueling boron concentrations.

2 21 0 2/06/02 Updated to Unit 2 Cycle 21.

Page 3 of 7

PRAIRIE ISLAND NUCLEAR GENERATING PLANT Core Operating Limits Report Record of Revision Unit Cycle Revision Approval No. Date Remarks 2 21 1 10/02/02 Revised to support License Amendment 149 changes, including revision of all references to TS, revision of FQ symbols, addition of Table 4, ITC limits, DNB limits and refueling boron concentrations. Also revised to include an additional V(z) curve to give greater FQ margin between 13.0 and 16.0 GWd/MTU.

1 22 0 11/25/02 Updated to Unit 1 Cycle 22. Updated Tables 1 and 2 and Figures 2a through 2f with revised bounding V(z) values. Incorporated new Figure 2g with additional bounding V(z) values.

Updated Table 3 with revised minimum shutdown margin limits. Deleted and revised text to eliminate duplication with the Technical Specifications and the Bases.

2 22 0 9/19/03 Updated to Unit 2 Cycle 22. Updated Tables 1 and 2. A reduced number of exposure ranges were calculated in Table 1, therefore new Figures 2a through 2e with revised bounding V(z) values replaced Figures 2a through 2f. New Figure 2f replaced Figure 2g for the 2 tier band bounding V(z) values. Updated Table 3 with revised minimum shutdown margin limits. Deleted and revised text to eliminate duplication with the Technical Specifications and the Bases.

1 22 1 7/6/04 Revision to incorporate Westinghouse Safety Analysis Transition per LA 162/153. Revision 1 contains transitional values for the OP/OT T Trip setpoints that will be used while the physical changes are implemented.

2 22 1 7/6/04 Revision to incorporate Westinghouse Safety Analysis transition per LA 162/153. Revision 1 contains transitional values for the OP/OT T Trip setpoints that will be used while the physical changes are implemented.

2 22 2 7/12/04 Revised Fq limit from 2.4 to 2.5. Removed OP and OT delta-T setpoints based on NMC methodology and replaced with Westinghouse developed setpoints.

Page 4 of 7

PRAIRIE ISLAND NUCLEAR GENERATING PLANT Core Operating Limits Report Record of Revision Unit Cycle Revision Approval No. Date Remarks 1 22 2 7/16/04 Revised Fq limit form 2.4 to 2.5. Removed OP and OT delta-T setpoints based on NMC methodology and replaced with Westinghouse developed setpoints.

1 23 0 10/20/04 Updated to Unit 1 Cycle 23.

2 23 0 - Not used due to core redesign.

2 23 1 5/19/05 Updated to Unit 2 Cycle 23 and to support redesign of Unit 2 Cycle 23 core.

1 23 1 7/11/05 Revised ITC upper limit from < 0 pcm/°F for power levels > 70% RTP to less than a line that slopes linearly from 0 pcm/F at 70% RTP to -2.9 pcm/F at 100% RTP. Revised the title of Figure 3 to reference T.S. 3.1.4 Condition B and revised the title of Figure 4 to reference T.S. 3.1.4 Condition A. Added references 24 and 25 to include the 50.59 screenings written to issue revision 1.

1 24 0 5/10/06 Updated to Unit 1 Cycle 24.

1 24 1 8/7/06 Updated Table 3 to reflect the correct Fqw(z) penalty factors.

2 24 0 11/26/06 Updated to Unit 2 Cycle 24 Modes 5 and 6.

2 24 1 12/6/06 Updated to Unit 2 Cycle 24 for Modes 1-6.

2 24 2 9/4/07 Revised to support LA-179/169. Revised reference 24 to include the revision number (revision 0) and the correct date of the report (January 2005). Revised references 6a, 6b, 6c, and 8 to say Deleted. These references referred to the old LBLOCA methodology and model.

1 24 2 2/11/08 Updated Table 1 to reflect correct Shutdown Margin Requirements and added Figures 6A through 6H.

Page 5 of 7

PRAIRIE ISLAND NUCLEAR GENERATING PLANT Core Operating Limits Report Record of Revision Unit Cycle Revision Approval No. Date Remarks 2 24 3 2/11/08 Updated Table 1 to reflect correct Shutdown Margin Requirements and added Figures 6A through 6H.

1 25 0 2/24/08 Updated to Unit 1 Cycle 25 1 25 1 5/28/08 Updated Table 2 to reflect the correct W(z) at a burnup of 150 MWd/MTU and a core height of 6.20 feet 2 25 0 9/26/08 Updated for Unit 2 Cycle 25 1 26 0 9/24/09 Updated for Unit 1 Cycle 26 2 26 0 5/3/10 Updated for Unit 2 Cycle 26 2 26 1 5/17/10 Updated to include part power W(z) factors 1 26 1 9/2/10 Updated for second set of W(z) factors 2 26 2 9/30/10 Updated for Measurement Uncertainty Recapture power uprate to 1677 MWth and for a second set of W(z) factors 1 26 2 9/30/10 Updated for Measurement Uncertainty Recapture power uprate to 1677 MWth 1 26 3 12/17/10 Updated SDM in Table 1 for Mode 2 to say 1.9.

1 27 0 5/5/11 Updated for Unit 1 Cycle 27 1 27 1 6/2/11 Updated for Unit 1 Cycle 27 Modes 1 through 6 2 27 0 3/28/12 Updated for Unit 2 Cycle 27 1 28 0 11/29/12 Updated for Unit 1 Cycle 28 Page 6 of 7

PRAIRIE ISLAND NUCLEAR GENERATING PLANT Core Operating Limits Report Record of Revision Unit Cycle Revision Approval No. Date Remarks 2 28 0 11/23/13 Updated for Unit 2 Cycle 28 1 29 0 10/23/14 Updated for Unit 1 Cycle 29 2 29 0 11/05/15 Updated for Unit 2 Cycle 29 1 30 0 10/25/16 Updated for Unit 1 Cycle 30 2 30 0 10/24/17 Updated for Unit 2 Cycle 30 1 31 0 09/06/18 Updated for Unit 1 Cycle 31 2 31 0 10/14/19 Updated for Unit 2 Cycle 31 Page 7 of 7

Core Operating Limits Report Unit 2, Cycle 31 Revision 0 PRAJRIE ISLAND NUCLEAR GENERATING PLANT CORE OPERATING LIMITS REPORT UNIT 2 ~ CYCLE 31 REVISION0 Reviewed By: _n_,___,.[C'---'--~.__,__y()"--"'---1,,JL'---'--=,""--'-.K"'-"--9_

~athew

  • Date: ( II 0 12._ 20 l9 Manager, Strategic Engineering Supervisor, Nuclear Analysis & Design

/~ ~ ...

  • Approved By: * *Lfd:2c~d,,o NateBibus Director, Fleet Engineering Note: Thls report is not part of the Technical Specifications This report is referenced in the Technical Specifications Page 1 of 26

Core Operating Limits Report Unit 2, Cycle 31 Revision O PRAIRIE ISLAND NUCLEAR GENERATING PLANT CORE OPERATING LIMITS REPORT UNIT 2 - CYCLE 31 REVISION0 This report provides the values of the limits for Unit 2 Cycle 31 as required by Technical Specification 5.6.5. These values have been established using NRC approved methodology and are established such that all applicable limits of the plant safety analysis are met. The Technical Specifications affected by this report are listed below:

1. 2.1.1 Reactor Core Safety Limits
2. 3.1.1 Shutdown Margin Requirements
3. 3.1.3 Isothermal Temperature Coefficient (ITC)
4. 3 .1.5 Shutdown Bank Insertion Limits
5. 3.1.6 Control Bank Insertion Limits
6. 3.1.8 Physics Tests Exceptions - MODE 2
7. 3.2.1 Heat Flux Hot Channel Factor (FQ(z))
8. 3.2.2 Nuclear Enthalpy Rise Hot Channel Factor (F~)
9. 3.2.3 Axial Flux Difference (AFD)
10. 3.3.1 Reactor Trip System (RTS) Instrumentation Overtemperature 11T and Overpower 11T Parameter Values for Technical Specification Table 3.3.1-1 (Note 1 and Note 2)
11. 3.4.1 RCS Pressure, Temperature, and Flow - Departure from Nucleate Boiling (DNB) Limits
12. 3.9.1 Refueling Boron Concentration
1. 2.1.1 Reactor Core Safety Limits Reactor Core Safety Limits are shown in Figure 1.

Reference Technical Specification 2.1.1.

2. 3 .1.1 Shutdown Margin Requirements Minimum Shutdown Margin requirements are shown in Table 1.

Reference Technical Specification 3 .1.1.

Page 2 of 26

Core Operating Limits Report Unit 2, Cycle 31 Revision O

3. 3.1.3 Isothermal Temperature Coefficient (ITC)

ITC Upper limit:

a. < 5 pcm/°F for power levels< 70% RTP; and
b. a line which slopes linearly from
i. 0 pcm/°F at a power level= 70% RTP to ii. -1.5 pcm/°F at a power level= 100% RTP ITC Lower limit:
a. -43.15 pcm/°F Reference Technical Specification 3.1.3.
4. 3 .1.5 Shutdown Bank Insertion Limits The shutdown rods shall be fully withdrawn.

Reference Technical Specification 3.1.5.

5. 3 .1.6 Control Bank Insertion Limits The control rod banks shall be limited in physical insertion as shown in Figures 2, 3, and 4.

The control rod banks withdrawal sequence shall be Bank A, Bank B, Bank C, and finally BankD.

The control rod banks shall be withdrawn maintaining 128 step tip-to-tip distance.

Reference Technical Specification 3 .1.6.

6. 3.1.8 Physics Tests Exceptions - MODE 2 Minimum Shutdown Margin requirements during physics testing are shown in Table 1.

Reference Technical Specification 3 .1. 8.

Page 3 of26

Core Operating Limits Report Unit 2, Cycle 31 Revision 0

7. 3.2.1 Heat Flux Hot Channel Factor (FQ@

The Heat Flux Hot Channel Factor shall be within the following limits:

CFQ=2.50 K(Z) is a constant value= 1.0 at all elevations.

The HFP W(Z) values are provided in Table 2 and Table 4.

The W(Z) values in Table 2 and Table 4 are applicable to Figure 5.

The data in Tables 2 and 4 should be used independently; cross interpolation or extrapolation between W(Z) sets is prohibited.

The Part Power W(Z) values for 75% .'.SP < 85% and Part Power W(Z) values for 85 .'.SP < 95% are provided in Table 6.

The W(Z) values in Table 6 are applicable to Figure 5.

The FwQ(Z) Penalty Factors associated with Figure 5 and Table 2 are provided in Table 3.

The FwQ(Z) Penalty Factors associated with Figure 5 and Table 4 are provided in Table 5.

The W(Z) values in Table 4 are based on a steady-state model with perturbed Axial Flux Difference (AFD) that simulates a Delta-Axial-Offset (D-AO) of -4%

for the entire cycle. D-AO is defined as the measured Axial Offset (AO) less the predicted AO from Table 2. The ranges of applicability for the Table 2 and 4 W(z) values are defined below:

1. Table 2 values should be used when D-AO is in the range of +/-3%

of the Table 2 supplied AO.

2. Table 4 values should be used when D-AO is more negative than

-3% and more positive than -7% of the Table 2 supplied AO.

Page 4 of26

Core Operating Limits Report Unit 2, Cyc;le 31 Revision 0 The HFP W(Z) values are generated assuming that they will be used for full power surveillance. Part power W(Z) values are only required to be used when the part power surveillance is performed using the moveable incore detector system.

When a part power surveillance is performed from BOC through 150 MWd/MTU and at a power level specified for Table 6, the W(Z) values provided in Table 6 should be used. When a part power surveillance is performed after 150 MWD/MIU, or at a power level other than those specified for Table 6, the HFP W(Z) values in Table 2 or Table 4 should be used.

W(Z) values should be multiplied by the factor 1/P, when P > 0.5. When Pis :S 0.5, the W(Z) values should be multiplied by the factor 1/(0.5), or 2.0. This is consistent with the adjustment in the FQ(Z) limit at part power conditions.

Reference Technical Specification 3.2.1.

8. 3.2.2 Nuclear Enthalpy Rise Hot Channel Factor (F6.JLl The Nuclear Enthalpy Rise Hot Channel Factor shall be within the following limits:

F6.H :s; 1.77 x [1 + 0.3(1- P)]

where: Pis the fraction of RATED THERMAL POWER at which the core is operating.

Reference Technical Specification 3 .2.2.

9. 3.2.3 Axial Flux Difference (AFD)

The indicated axial flux difference shall be maintained within the allowed operational space defined by Figure 5.

Reference Technical Specification 3.2.3.

Page 5 of26

Core Operating Limits Report Unit 2, Cycle 31 Revision 0

10. 3.3.1 Reactor Trip System (RTS) Instrumentation Overtemperature LiT and Overpower LiT Parameter Values for Technical Specification Table 3.3.1-1 (Note 1 and Note 2):

Overtemperature LiT Setpoint Overtemperature LiT setpoint parameter values:

LiTo = Indicated LiT at RATED THERMAL POWER,%

T Average temperature, °F T' = 560.0 °F p = Pressurizer Pressure, psig P' = 2235 psig Kr ~ 1.17 K2 = 0.014 /°F K3 = 0.00100 /psi

'tr = 30 seconds

't2 = 4 seconds f(Lll) = A :function of the indicated difference between top and bottom detectors of the power range nuclear ion chambers. Selected gains are based on measured instrument response during plant startup tests, where qt and qb are the percent power in the top and bottom halves of the core respectively, and qt + qb is total core power in percent of RATED THERMAL POWER, such that (a) For qt - qb within-13, +8 % f(LiI) = 0 (b) For each percent that the magnitude of qt - qb exceeds +8%

the LiT trip setpoint shall be automatically reduced by an equivalent of 1. 73 % of RATED THERMAL POWER.

(c) For each percent that the magnitude of qt - qb exceeds -13 %

the LiT trip setpoint shall be automatically reduced by an equivalent of3.846 % of RATED THERMAL POWER.

Overpower LiT Setpoint Overpower LiT setpoint parameter values:

LiTo = Indicated LiT at RATED THERMAL POWER,%

T = Average temperature, °F T' = 560.0 °F

~ ~ 1.11 Ks = 0.0275/°F for increasing T; 0 for decreasing T K6 = 0.002/°F for T > T'; 0 for T ~ T'

't3 = 10 seconds Reference Technical Specification 3.3.1.

Page 6 of26

Core Operating Limits Report Unit 2, Cycle 31 Revision 0

11. 3.4.1 RCS Pressure, Temperature, and Flow - Departure from Nucleate Boiling (DNB)

Limits The DNB Limits are:

Pressurizer pressure limit = 2190 psia RCS average temperature limit= 564°F RCS total flow rate limit= 178,000 gpm Reference Technical Specification 3 .4 .1.

12. 3.9.1 Refueling Boron Concentration.

The boron concentration of the reactor coolant system and the refueling cavity shall be sufficient to ensure that the more restrictive of the following conditions is met:

a) Keff :s; 0.95 b) 2000 ppm c) The Shutdown Margin specified in Table 1 Reference Technical Specification 3.9.1.

Page 7 of26

Core Operating Limits Report Unit 2, Cycle 31 Revision O REFERENCES (NRC Approved Methodologies for COLR Parameters)

1. NSPNAD-8101-A, "Qualification of Reactor Physics Methods for Application to Prairie Island,"

Revision 2, October 2000.

2. NSPNAD-8102-PA, "Prairie Island Nuclear Power Plant Reload Safety Evaluation Methods for Application to PI Units," Revision 7, July 1999.
3. NSPNAD-97002-PA, "Northern States Power Company's "Steam Line Break Methodology,"

Revision 1, October 2000.

4. WCAP-9272-P-A, "Westinghouse Reload Safety Evaluation Methodology," July, 1985.

5.a WCAP-10054-P-A, "Westinghouse Small Break ECCS Evaluation Model using the NOTRUMP Code," August, 1985.

5.b WCAP-10054-P-A, "Westinghouse Small Break ECCS Evaluation Model using the NOTRUMP Code," Addendum 2 Revision 1, July 1997.

6. WCAP-16045-P-A Addendum 1-A, "Qualification of the NEXUS Nuclear Data Methodology,"

August 2007.

7. WCAP-10924-P-A, Volume 1, Revision 1, and Volume 2, Revision 2, "Westinghouse Large Break LOCA Best Estimate Methodology," September 2005.
8. XN-NF-77-57-(A), XN-NF-77-57, Supplement 1 (A), "Exxon Nuclear Power Distribution Control for Pressurized Water Reactors Phase II," May 1981.
9. WCAP-13677-P-A, "10 CFR 50.46 Evaluation Model Report: W-COBRA/TRAC 2-Loop Upper Plenum Injection Model Update to Support ZIRLO' Cladding Options," February 1994.
10. NSPNAD-93003-A, "Prairie Island Units 1 and 2 Transient Power Distribution Methodology,"

Revision 0, April 1993.

11. NAD-PI-003, "Prairie Island Nuclear Power Plant Required Shutdown Margin During Physics Tests," Revision 0, January 2001.
12. NAD-PI-004, "Prairie Island Nuclear Power Plant FwQ(Z) Penalty With Increasing [FeQ(Z) / K(Z)

Trend," Revision 0, January 2001.

13. WCAP-10216-P-A, Revision lA, "Relaxation of Constant Axial Offset Control/ FQ Surveillance Technical Specification," February 1994.

ZIRLO' is a registered trademark of Westinghouse Electric Company LLC, its Affiliates and/or its Subsidiaries in the United States of America and may be registered in other countries throughout the world. All rights reserved. Unauthorized use is strictly prohibited.

Page 8 of26

Core Operating Limits Report Unit 2, Cycle 31 Revision 0

14. WCAP-8745-P-A, "Design Bases for the Thennal Overpower l1T and Thermal Overtem.perature l1T Trip Functions," September 1986.
15. WCAP-11397-P-A, "Revised Therm.al Design Procedure," April 1989.
16. WCAP-14483-A, "Generic Methodology for Expanded Core Operating Lim.its Report," January 1999.
17. WCAP-7588 Rev. 1-A, "An Evaluation of the Rod Ejection Accident m Westinghouse Pressurized Water Reactors Using Spatial Kinetics Methods," January 1975.
18. WCAP-7908-A, "FACTRAN - A FORTRAN N Code for Thermal Transients in a UO 2 Fuel.

Rod," December 1989.

19. WCAP-7907-P-A, "LOFTRAN Code Description," April 1984.
20. WCAP-7979-P-A, "TWINKLE - A Multidimensional Neutron Kinetics Computer Code,"

January 1975.

21. WCAP-10965-P-A, "ANC: A Westinghouse Advanced Nodal Computer Code," September 1986.
22. WCAP-11394-P-A, "Methodology for the Analysis of the Dropped Rod Event," January 1990.
23. WCAP-16045-P-A, "Qualification of the Two-Dimensional Transport Code PARAGON,"

August 2004.

24. WCAP-12910 Rev. 1-A, "Pressurizer Safety Valve Set Pressure Shift," May 1993.
25. WCAP-14565-P-A, "VIPRE-01 Modeling and Qualification for Pressurized Water Reactor Non-LOCA Thermal-Hydraulic Safety Analysis," October 1999.
26. WCAP-14882-P-A, "RETRAN-02 Modeling and Qualification for Westinghouse Pressurized Water ReactorNon-LOCA Safety Analyses," April 1999.
27. WCAP-16009-P-A, "Realistic Large-Break LOCA Evaluation Methodology Using the Automated Statistical Treatment Of Uncertainty Method (ASTRUM)," Revision 0, January 2005.
28. Caldon, Inc. Engineering Report-SOP, "Improving Thermal Power Accuracy and Plant Safety While Increasing Operating Power Level Using the LEFM ' System.," Revision 0, March 1997.
29. Caldon, Inc. Engineering Report-157P, "Supplem.entto Topical Report ER-SOP: Basis for a Power Uprate With the LEFM ' Check or CheckPlus' System.," Revision 5, October 2001.
30. WCAP-12610-P-A, "VANTAGE+ Fuel Assembly Reference Core Report," April 1995.

Page 9 of26

Core Operating Limits Report Unit 2, Cycle 31 Revision 0

31. WCAP-12610-P-A and CENPD-404-P-A, Addendum 1-A, "Optimized ZIRLO'," July 2006.
32. Design Equivalent Change 601000001607 Rev.0 "2R31 Core Reload IFBA/GAD" Optimized ZIRLO' is a trademark of Westinghouse Electric Company LLC, its Affiliates and/or its Subsidiaries in the United States of America and may be registered in other countries throughout the world. All rights reserved. Unauthorized use is strictly prohibited.

Page 10 of26

Core Operating Limits Report Unit 2, Cycle 31 Revision 0 Table 1 Minimum Required Shutdown Margin, %Ap Number of Charging Pumps Running**

Mode 1*

0-1 Pump 2 Pumps 3 Pumps 0 - 25000 MWd/MTU - - -

Mode 2*

0-1 Pump 2 Pumps 3 Pumps 0 - 25000 MWd/MTU 1.7 1.7 1.7 Physics Testing in Mode 2 0-1 Pump 2 Pumps 3 Pumps 0 - 25000 MWd/MTU 0.5 0.5 0.5 Tave~ 520°F (Most Reactive Rod Out)

Mode3 0-1 Pump 2 Pumps 3 Pumps 0 - 25000 MWd/MTU 2.0 2.0 2.0 350°F S Tave< 520°F (Most Reactive Rod Out)

Mode3 0-1 Pump 2 Pumps 3 Pumps 0MWd/MTU 2.0 2.0 2.0 3500 MWd/MTU 2.0 2.0 2.0 6000 MWd/MTU 2.0 2.0 2.0 11000 MWd/MTU 2.0 2.0 2.0 16000 MWd/MTU 2.0 2.0 2.0 25000 MWd/MTU 2.0 2.0 2.0 Operational Mode Definitions, as per TS Table 1.1-1.

  • For Mode 1 and Mode 2 with Keff;::: 1.0, the minimum shutdown margin requirements are provided by the Rod Insertion Limits.
    • Charging pump(s) in service only pertains to steady state operations. It does not include transitory operations. For example, operations such as starting a second charging pump in order to secure the operating pump would fall under the one pump in service column.

Note: Linear interpolation between burnup steps is allowed. Extrapolation is not allowed.

Page 11 of 26

Core Operating Limits Report Unit 2, Cycle 31 Revision O Table 1, Continued Minimum Required Shutdown Margin, 3/4Ap Number of Charging Pumps Running**

Mode4 200°F <Tave< 350°F (Most Reactive Rod Out) 0-1 Pump 2 Pumps 3 Pumps 0MWd/MTU 2.0 3.5 5.5 3500 MWd/MTU 2.0 4.0 6.0 6000 MWd/MTU 2.0 4.0 6.0 11000 MWd/MTU 2.0 3.5 5.5 16000 MWd/MTU 2.0 3.0 4.5 25000 MWd/MTU 2.0 2.0 2.5 68°F S Tave S 200°F (Most Reactive Rod Out)

Modes 0-1 Pump 2 Pumps 3 Pumps 0 MWd/MTU*** 2.0 4.0 6.5 3500 MWd/MTU 2.0 4.5 6.5 6000 MWd/MTU 2.0 4.5 6.5 11000 MWd/MTU 2.0 4.0 6.0 16000 MWd/MTU 2.0 3.5 5.5 25000 MWd/MTU 2.0 2.0 3.0 Operational Mode Definitions, as per TS Table 1.1-1.

    • Charging pump(s) in service only pertains to steady state operations. It does not include transitory operations. For example, operations such as starting a second charging pump in order to secure the operating pump would fall under the one pump in service column.
      • These values are also applicable for the Unit 2 Cycle 30 end of cycle.

Note: Linear interpolation between burnup steps is allowed. Extrapolation is not allowed.

Page 12 of26

Core Operating Limits Report Unit 2, Cycle 31 Revision O Table 1, Continued Minimum Required Shutdown Margin, %Ap Number of Charging Pumps Running**

Mode6 68°F :s; Tave < 200°F (ARI) 0-1 Pump 2 Pumps 3 Pumps 0 MWd/MTU*** 5.129 5.129 6.5 3500 .MWd/MTU 5.129 5.129 6.5 6000 MWd/MTU 5.129 5.129 6.5 11000 MWd/MTU 5.129 5.129 6.0 16000 MWd/MTU 5.129 5.129 5.129 25000 MWd/MTU 5.129 5.129 5.129 Mode6 68°F :s; Tave< 200°F (ARO) 0-1 Pump 2 Pumps 3 Pumps 0 MWd/MTU *** 5.129 5.129 8.0 3500 MWd/MTU 5.129 5.129 8.5 6000 MWd/MTU 5.129 5.129 8.5 11000 MWd/MTU 5.129 5.129 8.0 16000 MWd/MTU 5.129 5.129 7.0 25000 MWd/MTU 5.129 5.129 5.129 Operational Mode Definitions, as per TS Table 1.1-1.

    • Charging pump(s) in service only pertains to steady state operations. It does not include transitory operations. For example, operations such as starting a second charging pump in order to secure the operating pump would fall under the one pump in service column.
      • These values are also applicable for the Unit 2 Cycle 30 end of cycle.

Note: Linear interpolation between burnup steps is allowed. Extrapolation is not allowed.

Page 13 of26

Core Operating Limits Report Unit 2, Cycle 31 Revision 0 Table 2 - W(z) Values associated with Figure S(Top 10% and Bottom 8% excluded)*

Height BU [MWd/MTU]

150 1000 2000 3000 3500 4000 5000 7000 8000 9000

[ft] AO= AO= AO= AO= AO = AO= AO= AO = AO= AO=

0.08% 0.29% 0.33% 0 .15% -0.04% -0.20% -0.60% -1.38% -1.70% -1.95%

[BOTTOM] 0.00 1.0000 1 .0000 1 .0000 1 .0000 1 .0000 1 .0000 1.0000 1.0000 1 .0000 1 .0000 1

2 0.20 1.0000 1 .0000 1.0000 1 .0000 1 .0000 1.0000 1 .0000 1.0000 1 .0000 1.0000 3 0.40 1 .0000 1.0000 1.0000 1. 0000 1.0000 1.0000 1 .0000 1.0000 1 .0000 1.0000 4 0.60 1 .0000 1.0000 1.0000 1. 0000 1.0000 1.0000 1. 0000 1 .0000 1.0000 1 .0000 5 0.80 1 .0000 1. 0000 1 .0000 1. 0000 1. 0000 1 .0000 1.0000 1 .0000 1 .0000 1 .0000 6 1.00 1.2163 1 .2385 1 .2493 1. 2510 1 .2450 1 .2447 1. 2336 1. 2297 1. 2135 1 .2189 7 1. 20 1.2089 1 .2309 1.2412 1.2424 1 .2365 1 .2363 1.2254 1 . 2217 1. 2060 1. 2112 8 1 .40 1.2008 1. 2219 1 .2316 1.2322 1 .2263 1. 2263 1.2155 1 . 2119 1.1968 1 .2018 9 1 .60 1 .1935 1. 2118 1. 2207 1.2210 1. 2151 1.2147 1 .2043 1.2007 1 .1862 1 .1911 10 1.80 1 .1866 1. 2009 1.2090 1. 2092 1.2034 1 . 2021 1 .1926 1.1886 1 . 17 48 1 . 1796 11 2.00 1 .1788 1.1892 1.1964 1 . 1964 1 . 1908 1.1885 1.1806 1 .1755 1 .1626 1 . 167 4 12 2.20 1 .1710 1.1775 1.1837 1.1836 1 .1782 1 .1747 1.1683 1 .1623 1.1502 1.1550 13 2.40 1.1630 1 .1659 1 .1712 1.1708 1 .1655 1 .1612 1.1591 1 .1488 1 .1376 1 . 1423 14 2.60 1.1553 1 .1550 1 .1596 1 .1597 1 .1553 1 .1503 1 .1510 1 .1353 1 .1248 1.1295 15 2.80 1.1472 1.1434 1 .1496 1 .1501 1 .1486 1 .1403 1.1425 1 .1231 1 .1138 1.1180 16 3.00 1 .1401 1 . 1341 1.1420 1 .1422 1 .1433 1 .1315 1.1349 1.1154 1.1074 1 .1108 17 3.20 1 .1349 1 . 1308 1.1364 1 .1363 1.1372 1.1269 1.1291 1 .1130 1 .1051 1 .1090 18 3.40 1 .1290 1.1294 1.1307 1.1300 1.1308 1.1255 1 . 1226 1.1097 1 .1021 1.1064 19 3.60 1 .1238 1.1277 1 .1279 1.1270 1 .1250 1 .1240 1 .1176 1.1056 1 .0983 1 . 1040 20 3.80 1.1207 1 .1254 1 .1258 1.1253 1 .1214 1.1218 1.1149 1.1032 1. 0959 1.1026 21 4.00 1 .1186 1 .1226 1 .1227 1 .1223 1 .1193 1 .1192 1 .1128 1 .1022 1 .0947 1 .1018 22 4.20 1.1155 1 .1191 1 .1191 1 .1188 1 .1161 1 .1159 1 .1100 1 .1004 1.0934 1 .1007 23 4.40 1 .1121 1 .1153 1 . 1151 1 .1150 1 .1126 1.1123 1.1069 1. 0984 1 .0935 1 .0994 24 4.60 1 .1085 1 . 1112 1 .1109 1 .1109 1 .1088 1 .1084 1.1034 1 .0958 1 .0931 1 .0974 25 4.80 1 .1050 1 . 1071 1.1063 1 . 1066 1 . 1048 1.1043 1.0998 1 . 0941 1 .0923 1. 0950 26 5.00 1.1001 1.1020 1.1022 1 .1018 1 .1003 1.0995 1. 0953 1.0922 1 .0920 1 .0929 27 5.20 1 .0974 1 .0980 1 .0983 1. 0967 1.0954 1.0951 1. 0925 1.0913 1 .0921 1 .0925 28 5.40 1 . 1001 1 .0978 1 .0958 1. 0936 1. 0925 1.0936 1 .0924 1.0920 1 .0930 1.0936 29 5.60 1.1020 1 .1006 1 .0985 1. 0962 1 .0954 1.0953 1 .0948 1.0935 1 .0949 1.0944 30 5.80 1 .1048 1.1049 1 .1023 1 .1000 1 .0995 1 .0986 1 .0978 1.0974 1 .0983 1.0983 31 6.00 1 .1090 1.1093 1.1065 1 .1042 1 .1040 1 .1031 1.1021 1.1025 1.1022 1 .1032 32 6.20 1.1133 1 .1133 1.1103 1 .1081 1 .1084 1 .1075 1.1071 1.1071 1.1056 1 .1074 33 6.40 1.1171 1.1165 1.1135 1 . 1115 1 .1121 1 .1113 1 . 1117 1 . 1113 1 .1098 1 .1113 34 6.61 1.1206 1 .1195 1 .1164 1 .1145 1 .1155 1.1147 1.1160 1 .1151 1 . 1169 1 .1157 35 6.81 1.1232 1.1221 1 .1183 1.1165 1.1179 1.1171 1 . 1191 1 .1188 1.1227 1 .1201 36 7.01 1.1260 1.1255 1 .1207 1 .1192 1 . 1208 1 .1201 1 .1228 1.1229 1 .1277 1 .1240 37 7.21 1.1293 1.1288 1 .1236 1.1222 1 .1242 1.1235 1.1270 1.1267 1 .1324 1.1271 38 7.41 1 .1327 1 .1313 1 . 1263 1 .1250 1 .1273 1.1267 1 .1310 1.1310 1 .1369 1 .1319 39 7.61 1 .1355 1 . 1334 1 .1285 1 .1273 1 .1300 1 .1295 1 .1346 1.1369 1 .1407 1.1393 40 7.81 1.1371 1 .1344 1.1297 1 .1288 1 .1318 1 .1313 1 .1371 1.1423 1 .1434 1.1456 41 8.01 1 .1379 1 .1340 1.1296 1 .1289 1 .1321 1 .1316 1.1388 1.1470 1 .1468 1 .1510 42 8.21 1 .1370 1.1346 1.1305 1 .1301 1.1338 1 .1337 1.1389 1.1507 1 .1518 1.1555 43 8.41 1.1359 1 .1377 1.1342 1 . 1341 1.1381 1 .1384 1.1389 1.1541 1 .1573 1 . 1588 44 8.61 1 . 1357 1 .1420 1 .1389 1 . 1390 1.1434 1 .1434 1.1401 1 .1584 1.1614 1 . 1608 45 8. 81 1.1363 1 .1458 1 .1432 1 . 1438 1 . 1480 1 .1483 1.1425 1 . 1634 1.1649 1 .1618 46 9. 01 1.1429 1 .1494 1 .1489 1.1517 1 . 1509 1.1563 1.1499 1.1682 1 . 1711 1 .1655 47 9.21 1.1525 1 .1515 1 .1529 1 .1583 1.1538 1.1632 1.1612 1 .1780 1 .1767 1 .1748 48 9.41 1 .1610 1 . 1567 1 .1613 1 .1686 1 .1616 1 .1731 1.1729 1.1878 1 . 1855 1.1850 49 9.61 1.1705 1 . 1678 1 .1724 1 .1811 1.1729 1.1847 1.1827 1.1987 1 . 1958 1 .1931 50 9.81 1.1838 1 .1826 1.1836 1 .1938 1 .1848 1.1965 1 . 1923 1. 2116 1 .2056 1 .2011 51 10. 01 1 . 1976 1 .1974 1.1996 1.2119 1.1992 1 .2126 1 .2044 1.2207 1 .2182 1 .2115 52 10. 21 1. 2114 1 .2122 1.2156 1.2294 1 .2157 1.2271 1 .2160 1.2317 1 . 2287 1 .2211 53 10. 41 1.2195 1 .2214 1.2288 1. 2461 1 .2301 1.2430 1 .2298 1.2389 1 . 2387 1.2320 54 10.61 1.2288 1 .2304 1. 2395 1.2627 1. 2440 1 .2607 1 .2482 1.2453 1 .2482 1. 2454 55 10 .81 1 . 2421 1.2416 1.2473 1. 2684 1.2569 1 .2714 1. 2665 1.2525 1 .2508 1. 2553 56 11.01 1.0000 1 .0000 1 .0000 1. 0000 1.0000 1. 0000 1.0000 1.0000 1 .0000 1.0000 57 11.21 1.0000 1.0000 1.0000 1. 0000 1.0000 1. 0000 1.0000 1.0000 1 .0000 1.0000 58 11.41 1.0000 1.0000 1 .0000 1. 0000 1.0000 1.0000 1.0000 1.0000 1 .0000 1.0000 59 11. 61 1 .0000 1.0000 1 .0000 1 . 0000 1.0000 1. 0000 1.0000 1.0000 1 .0000 1.0000 60 11. 81 1.0000 1.0000 1 .0000 1 . 0000 1. 0000 1 .0000 1.0000 1 .0000 1 .0000 1.0000 fTOPl 61 12. 01 1 .0000 1. 0000 1. 0000 1. 0000 1. 0000 1 .0000 1.0000 1 .0000 1 .0000 1.0000

  • Linear extrapolation based on a line between 19,000 MWD/MTU and 22,000 MWD/MTU is adequate for addressing burnups beyond 22,000 MWD/MTU.

Page 14 of26

Core Operating Limits Report Unit 2, Cycle 31 Revision 0 Table 2 (cont.) - W(z) Values associated with Figure 5 (Top 10% and Bottom 8% excluded)*

Heiqht BU [MWd/MTU]

10000 10500 11000 12000 14000 15000 16000 17000 19000 22000

[ft] AO= AO= AO= AO= AO= AO= AO= AO = AO= AO=

-2.10% -2 .10% -2.04% -1.79% -1.13% -0.94% -0.91% -0.96% -1.18% -1.48%

[BOTTOM] 1 .0000 1 .0000 1.0000 1. 0000 1.0000 1.0000 1 .0000 1 .0000 1 . 0000 1 .0000 0.00 1

2 0.20 1.0000 1. 0000 1.0000 1. 0000 1 .0000 1.0000 1.0000 1 .0000 1. 0000 1 .0000 3 0.40 1.0000 1. 0000 1 .0000 1. 0000 1 .0000 1.0000 1.0000 1.0000 1 .0000 1 .0000 4 0.60 1.0000 1. 0000 1. 0000 1. 0000 1 .0000 1.0000 1.0000 1.0000 1 .0000 1.0000 5 0.80 1.0000 1.0000 1. 0000 1. 0000 1 .0000 1.0000 1.0000 1.0000 1 .0000 1.0000 6 1.00 1.2087 1.2010 1.2140 1.2017 1 .2053 1 . 1956 1.1968 1.2128 1 .1881 1.1984 7 1. 20 1.2014 1.1937 1 .2067 1.1947 1.1988 1 . 1893 1.1906 1.2062 1 .1817 1 .1910 8 1.40 1 .1924 1.1849 1.1976 1 . 1861 1 .1910 1 .1816 1 .1832 1.1983 1 .1740 1.1825 9 1 .60 1.1823 1 .1749 1.1874 1.1763 1 .1821 1 .1729 1 .1749 1.1896 1.1657 1.1734 10 1 .80 1 .1714 1 .1642 1 .1764 1.1660 1 .1727 1 .1640 1 .1665 1 .1806 1 . 157 4 1 . 1645 11 2.00 1 . 1599 1 .1530 1.1648 1 .1551 1.1630 1 .1547 1 .1578 1 .1715 1 . 1491 1.1558 12 2.20 1 .1482 1 .1415 1.1530 1.1440 1.1530 1 .1451 1 . 1490 1 .1620 1.1405 1.1467 13 2.40 1.1361 1 .1297 1.1407 1 .1323 1 .1422 1 .1346 1 .1390 1 .1515 1.1308 1.1362 14 2.60 1.1240 1.1177 1.1280 1 .1201 1 .1309 1.1237 1.1299 1 .1405 1.1206 1 .1251 15 2.80 1.1133 1.1075 1.1177 1 .1106 1 .1213 1 . 1143 1.1207 1.1302 1 .1112 1 .1149 16 3.00 1.1069 1 .1018 1 .1120 1 .1056 1 .1155 1.1088 1.1143 1 .1215 1 .1066 1.1103 17 3.20 1 .1051 1.1003 1 .1093 1 .1031 1 .1129 1.1070 1.1139 1 .1153 1 .1065 1.1109 18 3.40 1.1027 1.0983 1 .1059 1 .1000 1 .1095 1.1059 1.1132 1 .1108 1 .1091 1 . 1113 19 3.60 1 .1010 1.0980 1 .1025 1. 0979 1.1083 1.1058 1.1138 1 .1108 1 . 1116 1 .1107 20 3.80 1 .1006 1 .0988 1 .1007 1. 0973 1.1078 1 .1072 1 .1149 1 .1126 1 .1137 1.1123 21 4.00 1 .1004 1.0991 1.1000 1. 0968 1.1068 1 .1106 1 .1154 1 .1139 1 .1156 1.1179 22 4.20 1 .0998 1.0992 1.0987 1. 0962 1.1056 1 .1137 1 .1157 1 .1149 1 . 1171 1.1226 23 4.40 1.0988 1 .0990 1.0970 1. 0972 1.1042 1 .1163 1 .1156 1 .1154 1 .1180 1 .1267 24 4.60 1.0972 1 .0979 1.0963 1. 0974 1.1035 1 .1174 1 .1140 1.1146 1 .1171 1 .1287 25 4.80 1.0951 1 .0965 1.0954 1.0971 1.1024 1 .1178 1.1139 1.1131 1 . 1171 1.1295 26 5.00 1.0937 1 .0946 1.0939 1. 0962 1.1009 1 .1178 1.1147 1 . 1113 1 .1173 1.1298 27 5.20 1.0931 1 .0933 1. 0931 1. 0959 1.1002 1.1171 1 . 1151 1.1089 1 .1170 1.1298 28 5.40 1.0929 1. 0932 1.0935 1. 0972 1 .1010 1.1161 1 .1150 1.1066 1 .1160 1 .1289 29 5.60 1.0941 1.0949 1 .0957 1. 0981 1 .1018 1 .1154 1 .1153 1.1074 1 .1145 1.1275 30 5.80 1.0969 1 .0984 1 .0997 1 .1005 1 .1054 1 .1153 1 .1159 1.1128 1 .1168 1 .1315 31 6.00 1.1012 1.1020 1 .1039 1 .1044 1 . 1115 1.1179 1 .1188 1 .1193 1 .1237 1.1416 32 6.20 1.1070 1.1052 1 .1076 1 .1098 1 .1179 1 .1247 1.1234 1.1267 1 .1331 1.1529 33 6.40 1.1138 1.1096 1.1118 1 .1163 1 .1237 1 .1311 1 .1295 1.1383 1.1437 1.1635 34 6.61 1.1202 1 .1168 1 .1171 1 .1223 1 .1300 1.1369 1 .1396 1.1490 1 .1535 1.1734 35 6.81 1 .1252 1.1222 1 .1207 1 .1263 1 .1386 1.1407 1 .1476 1.1573 1 .1608 1.1803 36 7.01 1.1292 1.1293 1 .1261 1.1339 1.1467 1 .1431 1 .1544 1.1644 1 .1668 1.1856 37 7.21 1 . 1335 1 .1381 1.1339 1 .1425 1.1538 1.1479 1 .1605 1 .1707 1 . 1720 1 .1901 38 7.41 1 .1396 1 .1469 1.1422 1 .1497 1 .1601 1.1544 1.1655 1 .1758 1 .1761 1.1933 39 7.61 1 .14 75 1 .1547 1.1497 1 . 1561 1 .1653 1.1593 1 .1693 1 .1797 1 .1788 1.1950 40 7.81 1 . 1540 1 .1615 1.1564 1 .1613 1 .1691 1 .1631 1 .1717 1 .1820 1 . 1800 1 . 1949 41 8.01 1 .1596 1 . 1672 1.1620 1.1654 1.1716 1.1656 1.1725 1.1827 1.1794 1.1929 42 8.21 1 .1641 1 .1718 1.1666 1.1682 1 .1726 1.1669 1.1720 1 .1819 1 . 177 4 1 .1889 43 8.41 1.1673 1 .1751 1.1702 1.1696 1 .1720 1.1666 1.1694 1 .1789 1 . 1728 1.1835 44 8.61 1.1692 1.1770 1.1724 1.1694 1.1699 1.1654 1 .1657 1 .1748 1 .1681 1.1802 45 8.81 1.1701 1 .1777 1.1737 1 .1681 1.1674 1.1656 1.1645 1.1722 1.1690 1 . 1809 46 9.01 1.1721 1.1798 1.1778 1.1684 1.1676 1 . 1670 1 .1630 1 .1665 1 . 1661 1.1773 47 9.21 1.1800 1.1875 1.1818 1.1742 1 .1711 1.1668 1.1648 1 .1641 1.1662 1 . 1761 48 9.41 1.1881 1.1954 1.1889 1 .1802 1 . 17 46 1.1687 1.1666 1 .1619 1 .1672 1 . 17 49 49 9.61 1.1970 1.2040 1.1973 1 .1868 1 .1790 1.1721 1 .1686 1 .1605 1 . 1676 1 .1734 50 9.81 1 .2079 1.2147 1. 2052 1.1955 1 .1851 1.1749 1.1725 1 .1616 1 .1681 1.1735 51 10. 01 1.2163 1. 2227 1.2162 1 .2016 1.1886 1.1809 1.1759 1 .1660 1 .1726 1.1775 52 10.21 1.2255 1.2331 1. 2250 1 .2086 1.1935 1.1837 1.1829 1.1668 1.1795 1 . 1841 53 10. 41 1 .2329 1. 2423 1.2350 1.2144 1.1963 1.1866 1.1904 1.1731 1.1863 1.1908 54 10. 61 1. 2411 1. 2478 1. 2427 1.2214 1.1997 1.1912 1.1980 1 .1870 1 . 1938 1.1983 55 10. 81 1 .2494 1.2469 1 .2421 1.2284 1.2004 1.1945 1. 2037 1 .1962 1.1995 1.2045 56 11. 01 1.0000 1.0000 1 .0000 1. 0000 1.0000 1.0000 1 . 0000 1 .0000 1 .0000 1.0000 57 11 . 21 1.0000 1.0000 1. 0000 1. 0000 1.0000 1.0000 1. 0000 1 .0000 1 .0000 1.0000 58 11 . 41 1.0000 1.0000 1. 0000 1. 0000 1.0000 1.0000 1 .0000 1 .0000 1 .0000 1.0000 59 11 . 61 1.0000 1.0000 1 .0000 1. 0000 1.0000 1.0000 1.0000 1. 0000 1.0000 1.0000 60 11. 81 1.0000 1.0000 1. 0000 1. 0000 1.0000 1.0000 1 .0000 1. 0000 1 .0000 1.0000

[TOP] 61 12. 01 1.0000 1.0000 1. 0000 1. 0000 1.0000 1.0000 1 .0000 1 .0000 1.0000 1 .0000

  • Linear extrapolation based on a line between 19,000 MWD/MTU and 22,000 MWD/MTU is adequate for addressing burnups beyond 22,000 MWD/MTU.

Page 15 of26

Core Operating Limits Report Unit 2, Cycle 31 Revision O Table 3 FwQ(Z) Penalty Factor associated with Figure 5 and Table 2**

Cycle Burnup (MWD/MTU) FQ (z) Penalty Factor 0 1.0200 1695 1.0200 1867 1.0203 2039 1.0210 2210 1.0200 10109 1.0200 10280 1.0216 10452 1.0216 10624 1.0200 25000 1.0200

    • Linear interpolation is adequate for intermediate cycle burnups.

Page 16 of26

Core Operating Limits Report Unit 2, Cycle 31 Revision O Table 4-Negative Delta AO W(z) Values associated with Figure 5 (Top 10% and Bottom 8% excluded)*

Height BU [MWd/MTU]

150 1000 2000 3000 3500 4000 5000 7000 8000 9000

[ft] AO = AO= AO= AO= AO= AO= AO= AO= AO= AO=

-3.91% -3.70% -3.68% -3.85% -4.04% -4.20% -4.59% -5.38% -5.70% -5.95%

[BOTTOM] 0.00 1 .0000 1. 0000 1 .0000 1.0000 1.0000 1 .0000 1 .0000 1.0000 1. 0000 1 . 0000 1

2 0.20 1.0000 1.0000 1. 0000 1 .0000 1. 0000 1 .0000 1.0000 1. 0000 1 . 0000 1. 0000 3 0.40 1.0000 1. 0000 1. 0000 1 .0000 1 .0000 1.0000 1.0000 1.0000 1 .0000 1 .0000 4 0.60 1.0000 1.0000 1. 0000 1.0000 1 .0000 1. 0000 1.0000 1. 0000 1 .0000 1. 0000 5 0.80 1 .0000 1 .0000 1. 0000 1.0000 1 .0000 1 . 0000 1.0000 1. 0000 1 .0000 1.0000 6 1. 00 1 .1790 1 .1799 1 . 1911 1.1940 1 .1887 1 .1921 1.1861 1 .1595 1 .1415 1 .1351 7 1 .20 1 .1720 1.1724 1 .1834 1.1862 1 .1810 1 .1843 1.1785 1.1526 1 .1350 1.1287 8 1 .40 1.1637 1 .1635 1 . 17 42 1.1770 1 . 1718 1.1749 1 .1694 1.1442 1 .1272 1.1209 9 1.60 1.1544 1.1535 1 . 1637 1 .1664 1 . 1614 1.1642 1.1589 1 .1347 1 .1182 1 .1120 10 1.80 1.1444 1 .1427 1 .1524 1 .1549 1.1500 1.1526 1.1477 1 .1246 1 .1087 1 .1027 11 2.00 1 . 1338 1 .1312 1 .1403 1.1427 1 .1379 1 . 1403 1.1357 1.1141 1 .0988 1 .0930 12 2.20 1 . 1232 1.1197 1.1282 1 .1304 1 .1258 1 . 1278 1.1237 1 . 1034 1 .0889 1. 0832 13 2.40 1 .1127 1 .1082 1 . 1161 1 .1180 1 .1136 1 .1153 1 . 1115 1. 0926 1 .0787 1.0733 14 2.60 1.1026 1 .0970 1 .1044 1 .1061 1 .1018 1 .1033 1.0998 1 . 0821 1. 0685 1. 0631 15 2.80 1.0928 1.0867 1.0927 1.0941 1.0900 1 . 0912 1.0882 1 . 0723 1 .0605 1.0555 16 3.00 1.0868 1.0815 1.0855 1. 0863 1.0825 1 .0835 1.0811 1. 0673 1 .0576 1 .0531 17 3.20 1.0868 1.0809 1.0853 1.0859 1.0823 1. 0831 1. 0809 1.0674 1 .0579 1 .0535 18 3.40 1.0859 1.0813 1.0839 1 .0845 1 . 0811 1. 0818 1 .0796 1.0678 1 . 0581 1.0536 19 3.60 1 .0845 1.0823 1. 0836 1 .0833 1.0793 1.0800 1. 0777 1.0707 1 .0598 1.0565 20 3.80 1 .0834 1 .0834 1 .0839 1 .0835 1. 0789 1.0799 1. 0774 1.0745 1. 0633 1 . 0610 21 4.00 1 .0835 1 .0843 1. 0846 1. 0842 1. 0801 1. 0811 1.0789 1.0776 1. 0666 1. 0648 22 4.20 1 .0854 1.0862 1. 0860 1.0844 1. 0814 1.0825 1.0806 1.0804 1 . 0699 1 .0685 23 4.40 1.0879 1.0882 1. 0878 1.0860 1.0835 1 .0847 1.0830 1.0831 1 . 07 44 1 .0719 24 4.60 1.0901 1. 0898 1. 0891 1.0873 1. 0851 1.0863 1.0848 1 .0849 1 . 0784 1.0760 25 4.80 1.0919 1.0909 1.0902 1. 0883 1.0863 1 .0876 1.0864 1.0865 1. 0819 1 .0799 26 5.00 1.0933 1.0926 1. 0907 1.0888 1 .0877 1 .0884 1.0873 1 . 0875 1. 0851 1. 0834 27 5.20 1 .0949 1.0950 1 . 0912 1 .0893 1. 0898 1 .0892 1 .0886 1.0888 1 .0880 1.0867 28 5.40 1 .0975 1. 0971 1. 0931 1 .0911 1 . 0921 1. 0912 1 .0907 1.0912 1.0906 1 .0896 29 5.60 1 .1001 1 .0990 1. 0963 1. 0942 1. 0938 1 .0946 1 .0926 1.0935 1 .0929 1 .0924 30 5.80 1 .1050 1 .1034 1 .1009 1. 0987 1. 0982 1.0994 1.0974 1 .0971 1. 0965 1.0965 31 6.00 1.1104 1 .1085 1 .1056 1 .1035 1.1034 1 .1045 1 .1030 1.1023 1 .1006 1.1007 32 6.20 1 .1148 1 .1125 1 .1095 1.1073 1 .1078 1 .1089 1.1077 1 .1076 1 .1059 1 .1047 33 6.40 1 .1188 1 .1160 1 .1129 1.1110 1 .1117 1 .1128 1 . 1121 1 .1125 1 .1133 1 .1104 34 6. 61 1.1230 1 .1193 1 .1175 1.1177 1 .1153 1 .1165 1.1162 1 .1183 1 .1202 1 .1180 35 6. 81 1 . 1278 1.1225 1 . 1236 1.1240 1 .1191 1 . 1191 1.1204 1 . 1238 1 .1258 1 .1240 36 7.01 1 .1322 1.1264 1.1296 1.1298 1.1232 1 . 1226 1.1250 1 . 1288 1 .1305 1 . 1321 37 7. 21 1 .1359 1.1299 1.1347 1 .1350 1.1270 1 .1263 1.1291 1 . 1334 1 .1363 1 .1423 38 7.41 1 .1400 1 .1338 1 .1403 1 .1406 1 . 1311 1 .1305 1.1337 1 . 1404 1; 1445 1 .1528 39 7.61 1.1456 1 .1392 1 .1473 1 .1475 1.1368 1 .1364 1.1406 1 . 1505 1 . 1543 1 .1627 40 7.81 1.1524 1 .1458 1 .1539 1 .1541 1 . 1437 1 .1435 1.1495 1.1594 1 .1631 1.1718 41 8.01 1.1599 1.1523 1 .1599 1 .1601 1 .1514 1 .1513 1.1579 1.1675 1 .1710 1 .1800 42 8.21 1.1667 1.1577 1.1650 1.1652 1 .1590 1 .1590 1 .1656 1.1749 1.1782 1 .1873 43 8. 41 1.1722 1.1637 1 .1691 1.1693 1 .1656 1.1657 1 . 1720 1 .1810 1 . 1841 1 .1931 44 8.61 1.1775 1 .1716 1 .1721 1 .1724 1 .1721 1 .1723 1.1779 1 .1866 1 . 1895 1.1982 45 8.81 1 .1860 1.1805 1.1769 1 . 1771 1 .1820 1 . 1820 1 .1875 1 .1952 1.1976 1 .2066 46 9.01 1 . 1982 1.1932 1 . 1901 1.1905 1 .1961 1.1959 1 .2014 1.2073 1. 2088 1.2177 47 9.21 1 .2103 1. 2061 1.2037 1. 2050 1 . 2102 1. 2100 1.2153 1 .2200 1 .2204 1 . 2290 48 9.41 1 .2214 1.2180 1.2172 1.2207 1 .2240 1. 2258 1. 2309 1.2347 1. 2343 1.2419 49 9.61 1.2304 1.2281 1 .2316 1 .2373 1 . 2383 1. 2426 1. 2478 1.2506 1 .2494 1.2559 50 9.81 1.2391 1 .2385 1 .2458 1 .2529 1.2533 1.2583 1. 2635 1.2653 1. 2633 1. 2691 51 10. 01 1 . 2516 1 .2543 1. 2592 1.2678 1.2673 1 .2733 1 . 2785 1 .2793 1 .2764 1 . 2816 52 10. 21 1.2635 1. 2700 1 .2711 1 .2820 1.2797 1.2876 1.2928 1.2925 1 . 2888 1.2932 53 10.41 1. 2773 1 .2834 1.2842 1 .2926 1.2937 1.2983 1. 3036 1.3027 1. 2982 1.3019 54 10.61 1.2957 1 .2993 1.3029 1 .3072 1.3130 1.3128 1.3177 1.3153 1. 3102 1.3132 55 10 .81 1. 3116 1. 3151 1.3206 1 .3249 1.3313 1.3304 1.3348 1 .3299 1 .3240 1.3264 56 11.01 1 .0000 1.0000 1 .0000 1 .0000 1. 0000 1 .0000 1.0000 1 .0000 1 .0000 1.0000 57 11. 21 1 .0000 1.0000 1.0000 1.0000 1. 0000 1 .0000 1.0000 1.0000 1. 0000 1. 0000 58 11.41 1.0000 1.0000 1.0000 1 .0000 1. 0000 1 .0000 1.0000 1. 0000 1. 0000 1.0000 59 11 . 61 1 .0000 1.0000 1.0000 1.0000 1. 0000 1 . 0000 1.0000 1.0000 1 .0000 1.0000 60 11. 81 1 .0000 1.0000 1. 0000 1.0000 1. 0000 1 .0000 1.0000 1.0000 1 .0000 1. 0000

[TOP] 61 12. 01 1 .0000 1.0000 1 . 0000 1.0000 1. 0000 1 .0000 1.0000 1 . 0000 1 .0000 1.0000

  • Linear extrapolation based on a line between 19,000 MWD/MTU and 22,000 MWD/MTU is adequate for addressing burnups beyond 22,000 MWD/MTU.

Page 17 of26

Core Operating Limits Report Unit 2, Cycle 31 Revision 0 Table 4 (cont.)-Negative Delta AO W(z) Values associated with Figure 5 (Top 10% and Bottom 8% excluded)*

Height BU [MWd/MTU]

10000 10500 11000 12000 14000 15000 16000 17000 19000 22000

[ft] AO= AO= AO= AO= AO= AO = AO= AO= AO= AO=

-6.09% -6 .10% -6.04% -5.79% -5 .13% -4.95% -4.92% -4.96% -5 .18% -5.48%

[BOTTOM] 0.00 1 .0000 1.0000 1 .0000 1. 0000 1.0000 1 .0000 1.0000 1.0000 1. 0000 1.0000 1

2 0.20 1.0000 1.0000 1. 0000 1 .0000 1 .0000 1.0000 1.0000 1. 0000 1. 0000 1.0000 3 0.40 1.0000 1.0000 1.0000 1.0000 1. 0000 1.0000 1.0000 1.0000 1. 0000 1.0000 4 0.60 1 .0000 1.0000 1.0000 1.0000 1.0000 1.0000 1. 0000 1 .0000 1. 0000 1.0000 5 0.80 1 .0000 1.0000 1.0000 1.0000 1.0000 1.0000 1. 0000 1 .0000 1 .0000 1.0000 6 1.00 1 .1410 1.1250 1.1241 1 .1243 1 .1347 1.1168 1. ~320 1 .1200 1 .1211 1 .1159 7 1. 20 1.1347 1 .1194 1 .1185 1 .1189 1 .1297 1.1125 1.1274 1 .1156 1 . 1166 1 . 1110 8 1 .40 1.1270 1.1126 1 .1116 1.1122 1.1236 1 .1072 1 .1216 1 . 1101 1 .1113 1 .1053 9 1 .60 1.1184 1.1049 1 .1039 1 .1046 1 .1169 1 .1014 1 .1153 1 .1043 1 .1057 1 .0995 10 1. 80 1 .1093 1.0969 1 .0959 1. 0968 1 .1100 1 .0957 1.1090 1. 0986 1 .1006 1 . 0943 11 2.00 1.1000 1.0887 1.0878 1.0889 1 .1031 1 .0901 1.1028 1. 0930 1. 0958 1 .0897 12 2.20 1 .0906 1.0805 1.0796 1.0808 1 .0960 1 .0843 1.0964 1 . 087 4 1. 0910 1.0849 13 2.40 1 .0808 1 .0720 1. 0711 1.0722 1 .0882 1.0778 1.0890 1. 0807 1 . 0851 1.0788 14 2.60 1 .0711 1 .0634 1.0624 1.0634 1.0805 1. 0711 1.0816 1.0737 1. 0789 1.0725 15 2.80 1 .0631 1 .0565 1 .0555 1.0566 1.0724 1.0653 1.0738 1. 0671 1. 0730 1.0660 16 3.00 1 .0596 1 .0538 1.0529 1. 0539 1.0677 1.0623 1. 0681 1.0622 1. 0680 1.0622 17 3.20 1.0597 1 .0543 1 .0535 1.0538 1.0675 1.0620 1.0672 1 .0615 1. 0657 1.0623 18 3.40 1.0617 1.0570 1.0565 1. 0556 1.0677 1.0655 1 .0675 1 .0660 1. 0662 1. 0658 19 3.60 1.0657 1.0615 1 .0612 1. 0596 1.0678 1.0703 1. 0677 1. 0711 1. 0666 1 . 0687 20 3.80 1.0701 1.0664 1 . 0662 1 .0643 1.0680 1 .0753 1. 0698 1 .0758 1.0694 1. 0742 21 4.00 1 . 07 41 1.0709 1.0709 1.0685 1.0693 1 .0803 1. 0758 1 .0807 1 .0768 1 . 0831 22 4.20 1. 0779 1 .0753 1.0754 1.0727 1.0741 1 .0853 1 . 0812 1 .0855 1.0834 1 . 0921 23 4.40 1 .0815 1 .0794 1.0797 1.0767 1 .0786 1 .0900 1.0865 1 .0900 1.0897 1 .1005 24 4.60 1 . 0841 1 .0825 1.0829 1.0794 1.0835 1 .0934 1.0904 1 . 0931 1. 0944 1 .1069 25 4.80 1 .0862 1 .0852 1.0857 1.0829 1 .0880 1 .0962 1.0935 1.0952 1. 0980 1 .1120 26 5.00 1.0881 1.0875 1.0882 1.0867 1. 0921 1.0986 1.0965 1. 0980 1 .1021 1 .1169 27 5.20 1.0896 1 .0896 1 .0903 1. 0901 1 .0959 1 .1007 1.0990 1 . 1011 1 .1068 1 .1211 28 5.40 1.0909 1.0913 1 .0922 1. 0932 1.0994 1.1023 1.1013 1 . 1041 1 .1110 1 . 1249 29 5.60 1.0925 1.0934 1 .0942 1. 0963 1 . 1031 1.1043 1.1056 1.1084 1 .1153 1 .1314 30 5.80 1.0968 1.0982 1 .0975 1 .1007 1 .1071 1.1097 1.1127 1 . 1171 1 .1271 1 .1458 31 6.00 1.1017 1.1037 1 .1026 1 .1048 1.1142 1 . 1196 1.1253 1 .1298 1 .1410 1 .1622 32 6.20 1 .1060 1.1085 1.1086 1.1113 1.1257 1 .1329 1 .1414 1.1439 1 .1532 1.1767 33 6.40 1 .1113 1.1143 1 .1159 1 .1242 1.1395 1.1476 1 .1566 1 .1571 1 .1652 1 .1910 34 6.61 1.1200 1.1234 1.1273 1.1398 1.1528 1 .1616 1 .1713 1 .1698 1 .1764 1. 2044 35 6.81 1.1313 1.1354 1.1396 1.1534 1.1637 1.1731 1 . 1833 1 .1798 1 .1847 1. 2142 36 7.01 1 .1422 1 .1468 1 .1510 1.1660 1 .1734 1 .1835 1 .1941 1 .1884 1 .1917 1.2223 37 7.21 1.1530 1.1582 1.1625 1.1780 1 .1832 1.1930 1. 2039 1 .1971 1 .1985 1 . 2303 38 7.41 1 .1639 1 .1696 1.1740 1.1889 1 .1928 1. 2012 1.2124 1 .2053 1. 2048 1 .2375 39 7. 61 1.1741 1 .1803 1 .1848 1.1988 1.2011 1 .2080 1 . 2194 1. 2120 1. 2095 1. 2428 40 7. 81 1.1833 1.1900 1 .1944 1.2073 1 .2080 1 .2133 1. 2247 1. 2172 1. 2126 1. 2463 41 8. 01 1 .1914 1.1987 1 .2030 1.2144 1 . 2135 1 .2168 1.2282 1. 2208 1.2142 1.2478 42 8. 21 1.1986 1.2062 1 .2103 1 .2200 1.2175 1 .2188 1 . 2299 1.2224 1.2133 1.2473 43 8. 41 1.2042 1.2124 1 .2163 1 .2238 1. 2195 1.2181 1. 2295 1. 2231 1 .2128 1. 2447 44 8.61 1 .2089 1.2171 1 .2207 1 .2258 1.2205 1 . 2167 1.2287 1. 2250 1. 2156 1. 2407 45 8.81 1 . 2168 1.2209 1. 2242 1 .2264 1.2240 1 . 2192 1.2286 1. 2281 1. 2188 1 .2371 46 9.01 1 .2275 1.2255 1. 2286 1 .2281 1.2268 1 .2184 1.2246 1 .2275 1 .2179 1. 2329 47 9.21 1 .2386 1.2290 1. 2323 1 .2344 1.2273 1.2212 1.2237 1. 2244 1 .2173 1 .2312 48 9.41 1. 2488 1.2394 1. 2390 1. 2405 1.2303 1.2255 1.2227 1 .2239 1. 2164 1 .2299 49 9.61 1. 2573 1.2548 1. 2467 1. 2467 1.2343 1. 2272 1. 2216 1. 2247 1 .2138 1 .2271 50 9.81 1. 2650 1 .2688 1. 2537 1.2553 1 . 2375 1.2290 1.2222 1.2269 1 .2125 1.2262 51 10. 01 1.2751 1 .2825 1.2637 1. 2638 1. 2436 1.2363 1.2237 1 . 2315 1 .2168 1.2323 52 10. 21 1.2881 1 .2957 1.2717 1 . 27 46 1.2470 1.2444 1.2258 1.2357 1 .2218 1. 2389 53 10. 41 1.3007 1 .3078 1. 2790 1.2851 1. 2493 1.2517 1.2272 1 . 2375 1. 2263 1.2447 54 10.61 1.3127 1.3196 1. 2892 1.2953 1. 2563 1.2594 1.2326 1.2425 1 . 2319 1. 2516 55 10.81 1.3215 1.3282 1. 2986 1.3026 1. 2651 1.2648 1. 2403 1.2500 1. 2358 1 .2570 56 11. 01 1.0000 1. 0000 1 .0000 1.0000 1.0000 1.0000 1. 0000 1. 0000 1 .0000 1.0000 57 11. 21 1.0000 1. 0000 1 .0000 1.0000 1. 0000 1.0000 1.0000 1. 0000 1. 0000 1 .0000 58 11. 41 1 .0000 1. 0000 1 .0000 1.0000 1. 0000 1.0000 1. 0000 1. 0000 1. 0000 1.0000 59 11 .61 1.0000 1. 0000 1.0000 1.0000 1. 0000 1.0000 1. 0000 1. 0000 1. 0000 1.0000 60 11. 81 1 .0000 1.0000 1 .0000 1.0000 1. 0000 1.0000 1. 0000 1. 0000 1 .0000 1.0000 rroP1 61 12.01 1 .0000 1.0000 1 .0000 1.0000 1. 0000 1.0000 1. 0000 1. 0000 1. 0000 1.0000

  • Linear extrapolation based on a line between 19,000 MWD/MTU and 22,000 MWD/MTU is adequate for addressing burnups beyond 22,000 MWD/MTU.

Page 18 of 26

Core Operating Limits Report Unit 2, Cycle 31 Revision 0 Table 5 Negative Delta AO FwQ(Z) Penalty Factor associated with Figure 5 and Table 4**

Cycle Burnup (MWD/MTU) FQ(z) Penalty Factor 0 1.0200 1352 1.0200 1524 1.0219 1695 1.0233 1867 1.0235 2039 1.0225 2210 1.0208 2382 1.0200 25000 1.0200

    • Linear interpolation is adequate for intermediate cycle burnups.

Page 19 of 26

Core Operating Limits Report Unit 2, Cycle 31 Revision 0 Table 6 - W(z) Values Associated with Figure 5 for Part Power Surveillances*

(Top 10% and Bottom 8% excluded)

Height Part Power W(z) Functions (% of Hot Full Power) sot 90tt D-Bank@ 197 Steps:t: D-Bank @ 206 Steps:t:

[ft] HFP AO= 0.13% HFP AO= 0.13%

[BOTTOM]

1 0.00 1.0000 1.0000 2 0.20 1. 0000 1.0000 3 0.40 1 .0000 1.0000 4 0.60 1.0000 1.0000 5 0.80 1.0000 1.0000 6 1. 00 1.2293 1 . 2163 7 1. 20 1. 2200 1 . 2081 8 1 .40 1.2099 1 . 1992 9 1. 60 1 . 2015 1 . 1927 10 1. 80 1 . 1937 1 .1858 11 2.00 1 . 1858 1 . 1788 12 2.20 1 . 1751 1 . 1710 13 2.40 1 . 1667 1 . 1637 14 2.60 1 . 1582 1 . 1560 15 2.80 1 . 1486 1.1479 16 3.00 1 .1408 1.1415 17 3.20 1 .1349 1 . 1363 18 3.40 1 . 1270 1 .1304 19 3.60 1 . 1211 1 .1252 20 3.80 1 . 1167 1 . 1220 21 4.00 1 . 1133 1 . 1199 22 4.20 1 . 1096 1 . 1168 23 4.40 1 . 1036 1 . 1128 24 4.60 1.0994 1 .1092 25 4.80 1 . 0961 1 .1063 26 5.00 1.0906 1 .1020 27 5.20 1.0867 1 .0987 28 5.40 1. 0894 1 . 1020 29 5.60 1. 0900 1 . 1039 30 5.80 1. 0922 1 . 1067

  • W(z) values only valid for core average burnups :5 150 MWd/MTU t 80% of full power W(z) values are applicable for powers 75% :5 P < 85%

tt 90% of full power W(z) values are applicable for powers 85% :5 P < 95%

+ Rod insertion is given as a target value. Use control rods as necessary to control to target AO Page 20 of26

Core Operating Limits Report Unit 2, Cycle 31 Revision O Table 6 (cont.) - W(z) Values Associated with Figure 5 for Part Power Surveillances*

(Top 10% and Bottom 8% excluded)

Height Part Power W(z) Functions (% of Hot Full Power) sot 90tt D-Bank@. 197 Steps* D-Bank @. 206 Steps*

[ft] HFP AO= 0.13% HFP AO= 0.13%

31 6.00 1.0958 1.1116 32 6.20 1.0994 1 . 1159 33 6.40 1 . 1030 1 . 1203 34 6.61 1 .1052 1 . 1234 35 6. 81 1 . 1083 1 .1265 36 7.01 1.1119 1 . 1299 37 7.21 1 . 1158 1 . 1339 38 7.41 1 . 1191 1.1373 39 7.61 1 . 1231 1 .1415 40 7.81 1 . 1247 1 . 1431 41 8.01 1 . 1267 1 .1446 42 8.21 1 . 1271 1 .1444 43 8.41 1 .1266 1 .1440 44 8.61 1 . 1276 1 .1439 45 8.81 1 . 1289 1 . 1446 46 9.01 1 . 1380 1 . 1527 47 9.21 1 .1504 1 . 1638 48 9. 41 1 . 1610 1 . 1732 49 9.61 1 . 1734 1 .1844 50 9.81 1 .1892 1 . 1983 51 10. 01 1.2037 1 . 2122 52 10. 21 1.2208 1 .2272 53 10. 41 1.2305 1. 2346 54 10.61 1 . 2413 1. 2447 55 10. 81 1 . 2556 1. 2573 56 11 . 01 1.0000 1 . 0000 57 11 . 21 1.0000 1.0000 58 11 . 41 1.0000 1.0000 59 11 . 61 1.0000 1.0000 60 11 . 81 1. 0000 1.0000 rTOPl 61 12. 01 1 . 0000 1.0000

  • W(z) values only valid for core average burnups :,; 150 MWd/MTU t 80% of full power W(z) values are applicable for powers 75% :,; P < 85%

tt 90% of full power W(z) values are applicable for powers 85% :,; P < 95%

j: Rod insertion is given as a target value. Use control rods as necessary to control to target AO
j: Rod insertion is given as a target value. Use control rods as necessary to control to target AO Page 21 of26

Core Operating Limits Report Unit 2, Cycle 31 Revision O Figure 1 Reactor Core Safety Limits 680 660 WA'>'-

- nc ;i;:

H*>?,i:::n n, ,i:: I I

.... I ' ,..,_ ,..,_

iUnacceptable i I ' ,..,_

~

... i,...,

640 I ' ,-..

I'---

I""',

I"'-- ,..,__

I~

I\.

1-.....

I'--- ,-.. .... j\

,..._ I'\"

.l1sso osia I I'\ "I\.

u. 620 I'--- i-..

Ill,.

"ii

~

'j\

0 C) ctl I-

-I'--- ,..,_

- - ,.... -,-.. I"-,.

i\ \

I'\

I\ \

U)

{.)

~ 600 1-.....

I"'-- r--..

~

1,

~

IAcceptable I \.

[\ ~

I\ \ I\.

580 \ \ \

\ \ '

\ ~

'\

560 '

' \

540 0 0.2 0.4 0.6 0.8 1 1.2 1.4 Fraction of 1677 MWt Rated Thermal Power Page 22 of26

Core Operating Limits Report Unit 2, Cycle 31 Revision O Figure 2 Rod Insertion Limit, 128 Step Tip-to-Tip tn 150

-a.

en Q)

C:

0

'cij 0

a. 100

.lil::

C:

ct!

al 0 20 40 60 80 100 Power Level, % of Rated Thermal Power Bank Positions Given By:

  • Bank D = (150 / 63) * (P- 100) + 185
  • Bank C = (150 / 63) * (P- 100) + 185 + 128
  • Bank B = (150 I 63) * (P - 100) + 185 + 128 + 128 NOTE: The top of the active fuel height corresponds to 224 steps.

Page 23 of26

Core Operating Limits Report Unit 2, Cycle 31 Revision O Figure 3 Rod Insertion Limit, 128 Step Tip-to-Tip, One Bottomed Rod (Technical Specification 3.1.4, Condition B) 224 200 150 en Operation 0..

.....Q) Forbidden in Cl) this Region C:

0

100 "ui 0

a..

~

C cu Ill 50 0

0 20 40 60 80 100 Power Level,% of Rated Thermal Power Bank Positions Given By:

  • BankD=(l50/63)*(P-90)+224
  • Bank C = (150 / 63) * (P - 90) + 224 + 128 NOTE: The top of the active fuel height corresponds to 224 steps.

Page 24 of26

Core Operating Limits Report Unit 2, Cycle 31 Revision 0 Figure 4 Rod Insertion Limit, 128 Step Tip-to-Tip, One Inoperable Rod (Technical Specification 3.1.4, Condition A) 224 - - - - - - - - - - - ~ - - - - - - - - - - - - - - - -

200 150 (I) 0.

Operation

.....Q)

Cf) Forbidden in this Region c0

,.::::; 100
  • w 0

Cl.

...\,C C

C\1 co 50 0

0 20 40 60 80 100 Power Level, % of Rated Thermal Power Bank Positions Given By:

  • BankD=(l50/63)*(P-70)+224
  • Bank C = (150 / 63) * (P - 70) + 224 + 128 NOTE: The top of the active fuel height corresponds to 224 steps.

Page 25 of26

Core Operating Limits Report Unit 2, Cycle 31 Revision O Figure 5 Flux Difference Operating Envelope associated with Table 2, Table 4, and Table 6 110

-9 8 100 -

IUnacceptable I/ I \I Unacceptable I 90 \

80 I

I \

70 / I Acceptable I \ \

60 I I \\

0 a.

'#- 50 J T

r\.

-22 21 40 30 20 10 0

-25 -20 -15 -10 -5 0 5 10 15 20 25 Al%

Page 26 of26