05000285/FIN-2013013-02
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Failure to Furnish Evidence of an Activity Affecting Quality |
Description | The team identified a non-cited violation of 10 CFR Part 50, Appendix B, Criterion XVII, Quality Assurance Records, associated with the licensees failure to furnish evidence of an activity affecting quality associated with the 480 Vac breakers. Specifically, the licensee failed to maintain design documents that detailed the correct Digital Low Resistance Ohm (DLRO) values required for ensuring proper connections between the Square D Masterpact NW breaker/cradle assembly to the GE AKD-5, 480 Vac cubicle stabs. The licensee re-generated acceptance criteria to address this issue. This issue was entered into the licensees corrective action program as CR 2013-04032. The licensees failure to furnish evidence that showed the required DLRO values ensured proper connections between the Square D Masterpact NW breaker/cradle assemble to the GE AKD-5, 480 V cubicle stabs is a performance deficiency. The performance deficiency was determined to be more than minor, and therefore a finding, because it affected the design control attribute of the Mitigating Systems Cornerstone, and it directly affected the cornerstone objective to ensure availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Using Inspection Manual Chapter 0609, Appendix A, The Significance Determination Process (SDP) for Findings At-Power, dated July 1, 2012, the finding was determined to have very low safety significance (Green) because it: (1) was not a deficiency affecting the design and qualification of a mitigating structure, system, or component, and did not result in a loss of operability or functionality; (2) did not represent a loss of system and/or function; (3) did not represent an actual loss of function of at least a single train for longer than its allowed outage time or two separate safety systems out-of-service for longer than their Technical Specification allowed outage time; and (4) did not represent an actual loss of function of one or more non-Technical Specification trains of equipment designated as high safetysignificance in accordance with the licensees maintenance rule program. This finding had a cross-cutting aspect in the area of human performance, associated with the resources component, because the licensee failed to maintain complete, accurate, and up-to-date design documentation. Specifically, the licensee did not maintain the engineering process for determining acceptable DLRO values. |
Site: | Fort Calhoun |
---|---|
Report | IR 05000285/2013013 Section 1R21 |
Date counted | Mar 31, 2014 (2014Q1) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.21 |
Inspectors (proximate) | G George H Barrett J Hanna J Jacobson J Josey J Polickoski J Robles J Watkins J Wingebach M Hay N Patel R Deese R Haskell R Telson S Laur S Makor T Lighty A Scarbeary C Baron C Henderson C Sanders C Smith D Loveless F Ramirez |
Violation of: | 10 CFR 50 Appendix B Criterion XVII, Control of Purchased Material, Equipment, and Services Technical Specification |
CCA | H.7, Documentation |
INPO aspect | WP.3 |
' | |
Finding - Fort Calhoun - IR 05000285/2013013 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Fort Calhoun) @ 2014Q1
Self-Identified List (Fort Calhoun)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||