05000285/FIN-2014007-05
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Failure to correct conditions adverse to quality in the containment internal structure and auxiliary building |
| Description | The inspectors identified multiple examples of a green, non-cited violation of 10 CFR Part 50, Appendix B, Criterion XVI, Corrective Action, for the licensees failure to promptly identify and correct conditions adverse to quality. Specifically, the licensee failed to take appropriate corrective action since 1997 when it was identified that the containment internal structure and auxiliary building had discrepant documentation between the size of structural beams and columns shown in drawings versus calculations. Subsequently, the licensee evaluated the non-conformances to provide a reasonable assurance of operability, and planned corrective actions to restore the structures to design basis requirements. The failure to correct conditions adverse to quality is a performance deficiency. The licensee documented the finding in the corrective action program as Condition Report 2014-04219. The performance deficiency was determined to be more than minor because it adversely affected the Mitigating Systems cornerstone objective of ensuring the availability, reliability, and capability of the safety injection system and the shutdown cooling system. The inspectors evaluated the finding using Inspection Manual Chapter 0609, Appendix A, The Significance Determination Process (SDP) For Findings At-Power, Exhibit 2, Mitigating Systems Screening Questions, dated June 19, 2012, and determined that the finding is of very low safety significance (Green) because the finding was a deficiency affecting the design or qualification of a mitigating SSC that did not affect operability or functionality. The finding does not have a cross-cutting aspect because it is not reflective of current plant performance. |
| Site: | Fort Calhoun |
|---|---|
| Report | IR 05000285/2014007 Section 4OA2 |
| Date counted | Mar 31, 2014 (2014Q1) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71152 |
| Inspectors (proximate) | J Bozga J Kirkland J Wingebach M Hay W Smith |
| Violation of: | 10 CFR 50 Appendix B Criterion XVI |
| INPO aspect | |
| ' | |
Finding - Fort Calhoun - IR 05000285/2014007 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Fort Calhoun) @ 2014Q1
Self-Identified List (Fort Calhoun)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||