Watts Bar Nuclear Plant (Wbn), Unit 2 - Request for Approval of a Relief from the American Society of Mechanical Engineers, Section Xi Coverage Examinations for Preservice Inspection (PSI) - Number WBN-2/PSI-1, Revision 1, and Submittal of
ML16293A334
Person / Time
Site: Watts Bar Tennessee Valley Authority icon.png
Issue date: 10/05/2016
From: Shea J W
Tennessee Valley Authority
To:
Document Control Desk, Office of Nuclear Reactor Regulation
Shared Package
ML16293A318 List: ... further results
References
CNL-16-135
Download: ML16293A334 (32)


Text

Tennessee Valley Authority, 1101 Market Street, Chattanooga, Tennessee 37402 CNL-16-135 October 5, 2016 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Watts Bar Nuclear Plant, Unit 2 Facility Operating License No. NPF-96 NRG Docket No. 50-391 10 CFR 50.55a

Subject:

Watts Bar Nuclear Plant (WBN) Unit 2 -Request for Approval of a Relief from the American Society of Mechanical Engineers (ASME)Section XI Coverage Examinations for Preservice Inspection (PSI) -Number WBN-2/PSl-1, Revision 1, and Submittal of the WBN Unit 2 PSI Program Plan, Revision 11

Reference:

1. TVA letter to NRG, "Watts Bar Nuclear Plant (WBN) Unit 2 -American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code Transition

-Revised Commitment," dated September 1, 2011 (ML 102930299)

2. TVA letter to NRG, "Watts Bar Nuclear Plant (WBN) Unit 2 -American Society of Mechanical Engineers (ASME)Section XI Request for Relief WBN-2/PSl-1," dated October 11, 2010 (ML 11306A022)
3. TVA letter to NRC, "Watts Bar Nuclear Plant, Unit 2 -American Society of Mechanical Engineers,Section XI, Preservice Inspection . Summary Report," dated August 9, 2016 In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 50.55a, "Codes and Standards," paragraphs (g)(5)(iii) and (g)(6), Tennessee Valley Authority (TVA) is submitting a revised relief request for Nuclear Regulatory Commission (NRC) approval for the Watts Bar Nuclear Plant (WBN) Unit 2 Preservice Inspection (PSI) period. In accordance with Reference 1, the WBN Unit 2 PSI period ended with initial turbine-generator synchronization following initial criticality on June 3, 2016.

U.S. Nuclear Regulatory Commission CNL-16-135 Page 2 October 5, 2016 Enclosure 1 provides relief request WBN-2/PSl-1, Revision 1 that requests relief from the requirements of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel (B&PV) Code,Section XI, "Rules for lnservice Inspection of Nuclear Power Plant Components," Subarticle IWB-2200, "Preservice Examination," ASME Code Class 1, Table IWB-2500-1, and ASME Code Class 2, Table IWC-2500-1, which require either a volumetric examination of essentially 100 percent(%)

of the weld volume or a surface examination of essentially 100% of the weld area. The specific item numbers from Tables IWB-2500-1 and IWC-2500-1, for which relief is requested, are shown in Table 1 of Enclosure

1. The ASME B&PV Code,Section XI, 2001 Edition through 2003 Addenda was the code of record for the WBN Unit 2 PSI period. This revised relief request supersedes the one submitted by TVA for WBN Unit 2 in Reference
2. Attachment 1 to Enclosure 1 provides a compact disc (CD) containing the drawings that support the relief request. The definition of "essentially 100%" is provided by NRC Information Notice 98-42, "Implementation of 10 CFR 50.55a(g) lnservice Inspection Requirements," and Code Case N-460, "Alternative Examination Coverage for Class 1 and Class 2 Welds,Section XI, Division 1," which requires examination coverage of "more than 90 percent of the specified examination volume" in lieu of "essentially 100%." 1 O CFR 50.55a(g)(6) authorizes the NRC to grant relief for determinations under 10 CFR 50.55a(g)(5) when Code requirements are impractical.

TVA is requesting relief on the basis that the Code-required "essentially 100%" examination coverage is impractical due to physical obstructions and limitations imposed by design, geometry, or physical obstructions for the welds and associated components listed in Table 1 to Enclosure

1. As an alternative, TVA has invoked ASME Section XI Code Case N-460, which states: "when the entire examination volume or area cannot be examined due to interference by another component or part geometry, a reduction in examination coverage on any Class 1 or Class 2 weld may be accepted provided the reduction in coverage for that weld is less than 10%." Therefore, TV A is requesting relief only for those welds that were inspected and received Code coverage of 90% or less. Examination coverage of greater than 90% was not achieved for the welds listed in the proposed relief request and the applicable coverage percentage is specified in the relief request for each weld (Table 1 to Enclosure 1). The examination coverage achieved for the subject welds in conjunction with acceptable construction code examinations provides reasonable assurance that unallowable flaws do not exist in the subject component welds and that the welds are acceptable for service. Thus, an acceptable level of quality and safety was achieved and public health and safety was not endangered by allowing the proposed alternative examination coverage in lieu of the Code requirement.

The nondestructive examination (NOE) reports listed in Table 1 to Enclosure 1 are available for NRC review.

U.S. Nuclear Regulatory Commission CNL-16-135 Page 3 October 5, 2016 Enclosure 2 to this submittal contains Revision 11 to the WBN Unit 2 PSI Program Plan for NRC information.

This revision contains the final ASME Section XI examinations and results performed for the WBN Unit 2 PSI program. Additionally, in accordance with Reference 1, TVA previously submitted to the NRC the WBN Unit 2 PSI summary report (Reference

3) that provided an overview of the results from preservice examinations that were performed on components within the ASME Section XI boundary of WBN Unit 2 prior to initial turbine generator synchronization.

There are no regulatory commitments associated with this submittal.

Please address any questions regarding this request to Edward D. Schrull at 423-751-3850.

Respe *tfully, n .WdK--Vice resident, Nuclear Licensing

Enclosures:

1. American Society of Mechanical Engineers (ASME)Section XI Request for Relief WBN-2/PSl-1, Revision 1 2. Watts Bar Nuclear Plant Unit 2, Preservice Inspection Program Plan, Revision 11 cc (Enclosure):

NRC Regional Administrator

-Region II NRC Senior Resident Inspector

-Watts Bar Nuclear Plant NRR Project Manager -Watts Bar Nuclear Plant r Enclosure 1 Tennessee Valley Authority Watts Bar Nuclear Plant (WBN) Unit 2 American Society of Mechanical Engineers (ASME)Section XI Request for Relief WBN-2/PSl-1, Revision 1 ASME Code Class 1 and 2 Welds with Limited (</= 90%) Coverage Examinations for Preservice Inspection (PSI) I. American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel (B&PV) Code Component(s)

Affected ASME ASME Code Item Component Component Exam Code Examination Classes Category No. ID Description Method Ultrasonic Various, as Various, as Various, as Various, as testing (UT) 1 & 2 listed in listed in listed in listed in and Dye Table 1 Table 1 Table 1 Table 1 Penetrant (PT) Testing II. Applicable Code Edition and Addenda The ASME Boiler and Pressure Vessel B&PV Code,Section XI, 2001 Edition through 2003 Addenda was the code of record, as conditioned by 10 CFR 50.55a, for the PSI period for WBN Unit 2. In accordance with Reference 1, the PSI period for WBN Unit 2 ended with initial turbine-generator synchronization following initial criticality on June 3, 2016. Ill. Applicable Code Requirements ASME Section XI, Subarticle IWB-2200, "Preservice Examination," requires that "preservice examination be extended to include essentially 100% of the pressure retaining welds in all Class 1 components." ASME Section XI, Subarticle IWB-2500, "Examination and Pressure Test Requirements," states that components shall be examined and tested as specified in Table IWB-2500-1, which also requires either a volumetric examination of essentially 100 percent(%)

of the weld volume or a surface examination of essentially 100% of the weld area. The specific item numbers from Table IWB-2500-1 are shown in Table 1. ASME Code Class 2, Table IWC-2500-1, requires either a volumetric examination of essentially 100% of the weld volume or a surface examination of essentially 100% of the weld area. The specific item numbers from Table IWC-2500-1 are shown in Table 1. TVA has invoked ASME Section XI Code Case N-460, which states: "when the entire examination volume or area cannot be examined due to interference by another component or part geometry, a reduction in examination coverage on any Class 1 or Class 2 weld may be accepted provided the reduction in coverage for that weld is less than 10%." Therefore, TV A is requesting relief only for those welds that were inspected and received Code coverage of 90% or less. CNL-16-135 E1-1 of 29 IV. Reason for Request 10 CFR 50.55a(g)(5)(iii), "ISi program update: Notification of impractical ISi Code requirements," states: "If the licensee has determined that conformance with a Code requirement is impractical for its facility the licensee must notify the NRC and submit, as specified in § 50.4, information to support the determinations.

Determinations of impracticality in accordance with this section must be based on the demonstrated limitations experienced when attempting to comply with the Code requirements during the inservice inspection interval for which the request is being submitted.

Requests for relief made in accordance with this section must be submitted to the NRC no later than 12 months after the expiration of the initial or subsequent 120-month inspection interval for which relief is sought." 10 CFR 50.55a(g)(6) authorizes the Nuclear Regulatory Commission (NRC) to grant relief for determinations under 10 CFR 50.55a(g)(5) that code requirements are impractical.

In accordance with 10 CFR 50.55a(g)(6) and 10 CFR 50.55a(g)(5)(iii), TVA is requesting relief from the "essentially 100%" Code-coverage-required weld examination volume or area. As noted in Section Ill of this enclosure, Code Case N-460 states that a reduction in examination coverage on any Class 1 or Class 2 weld may be accepted provided the reduction in coverage for that weld is less than 10%, when the entire examination volume or area cannot be examined due to interference by another component or part geometry.

Therefore, TVA is requesting relief only for those welds that were inspected and received Code coverage of 90% or less. This relief request addresses ASME Section XI Code Class 1 and 2 welds with limited examination coverage in examination categories and item numbers as listed in Table 1. The examination limitations described in this relief request are inherent in the component design, geometry, and materials of construction utilized in the manufacture of the installed components given the original construction permit date for WBN Unit 2 of January 23, 1973. NRC Information Notice 98-42, "Implementation of 10 CFR 50.55a(g) lnservice Inspection Requirements," states, "'Esse.ntially 100 percent' examination is defined as more than 90 percent of the specified examination volume." Additionally, 10 CFR 50.55a(a)(3)(ii) endorses Regulatory Guide 1.147, Rev 17, which unconditionally approves the use of ASME Code Case N-460, "Alternative Examination Coverage for Class 1 and Class 2 Welds,Section XI, Division 1." Code Case N-460 states: "It is the opinion of the Committee that when the entire examination volume or area cannot be examined due to interference by another component or part geometry, a reduction in examination coverage on any Class 1 or Class 2 weld may be accepted provided the reduction in coverage for that weld is less than 10%." The above quote from Code Case N-460 is consistent with the guidance in Information Notice 98-42. This relief request supersedes the one submitted by TVA for WBN Unit 2 in Reference

2. CNL-16-135 E1-2 of 29 V. Impracticality of Compliance Relief is requested on the basis that the Code-required "essentially 100%'; examination coverage is impractical due to physical obstructions and limitations imposed by design, geometry, and/or physical obstructions for the welds and associated components listed in Table 1. For ASME Code Class 1 components, ASME Section XI, IWB-2200, "Preservice Examination" requires that "preservice examination be extended to include essentially 100% of the pressure retaining welds in all Class 1 components." Therefore, no alternate Class 1 welds are available for selection.

Compliance with the examination requirements of ASME Section XI would require significant modification of plant components to remove obstructions, redesign of plant systems/components, or replacement of components where geometry is inherent to the component design. For ASME Code Class 2 components, ASME Section XI, IWC-2200, "Preservice Examination," requires in part, that all examinations required for those components initially selected for examination for ISi, and not exempt, shall be completed prior to initial pla11t startup as a PSI. Compliance with the examination requirements of ASME Section XI would require significant modification of plant components to remove obstructions, redesign of plant systems/components, or replacement of components where geometry is inherent to the component design. VI. Proposed Alternative and Basis for Use TVA performed the ASME Section XI Code-required Preservice volumetric and surface examinations for WBN Unit 2 listed in Table 1, to the maximum extent possible, given the materials and configurations, utilizing qualified/certified personnel, approved procedures, and multiple inspection techniques.

The various types of ultrasonic beams, beam angles, and transducer shapes and sizes utilized for each examination are listed in Table 1 in the column titled Additional Information.

The welds listed in Table 1 were examined, to the maximum extent possible, utilizing qualified/certified personnel, qualified equipment, and approved procedures to meet the PSI acceptance standards of ASME Section XI 2001 Edition through the 2003 Addenda. Surface conditioning of the piping welds was performed to the extent necessary to preclude a reduction in coverage associated with weld crowns, weld shrinkage, and/or surface roughness.

These welds have not been in service and were acceptable to the construction code standards for installation.

The examinations performed on these welds for both construction code and the limited coverage preservice examination are sufficient to ensure structural adequacy of the subject welds. These welds also met the ASME Section Ill NOE acceptance criteria associated with construction.

The construction code radiography, while providing additional assurance of the structural integrity of the subject welds, is not qualified in accordance with ASME Section XI, Appendix VIII, and cannot be credited for ASME Section XI coverage.

The welds listed in Table 1 were subjected to an ASME Code Section Ill hydrostatic pressure test prior to initial plant startup. CNL-16-135 E1-3 of 29 The PSI examination, along with the construction NOE, provides reasonable assurance that unallowable inservice flaws do not exist in the subject welds or that they have been detected and repaired prior to placement into service. Thus, an acceptable level of quality and safety has been achieved and public health and safety has not been endangered by allowing the proposed alternative examination in lieu of the Code requirement.

Attachment 1 to Enclosure 1 provides a compact disc (CD) containing the drawings that support the relief request. VII. Duration of Proposed Alternative This relief request applies to the PSI period for Watts Bar Unit 2 that ended on June 3, 2016, at initial turbine-generator synchronization after initial criticality.

VIII. Precedents This relief request is similar to the following relief requests submitted by TVA for WBN Unit 1 and approved by the NRC:

  • PDl-2 (Reference
3)
  • 1-ISl-20 (Reference
4)
  • 1-ISl-16, 1-ISl-17, 1-ISl-18, and 1-ISl-19 (Reference
5) IX. References
1. TVA letter to NRC, "Watts Bar Nuclear Plant (WBN) Unit 2 -American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code Transition

-Revised Commitment," dated September 1, 2011 (ML 102930299)

2. TVA letter to NRC, "Watts Bar Nuclear Plant (WBN) Unit 2 -American Society of Mechanical Engineers (ASME)Section XI Request for Relief WBN-2/PSl-1," dated October 11, 2010 (ML 102930299)
3. NRC letter to TVA, "Watts Bar Nuclear Plant, Unit 1 -Safety Evaluation of Relief Requests PDl-2 and PDl-4 for the Second 10-Year lnservice Inspection Program for Reactor Pressure Vessel Weld Examinations (TAC Nos. MD4448 and MD4449)," dated February 29, 2008 (ML080630679)
4. NRC letter to TVA, "Watts Bar Nuclear Plant, Unit 1 -Safety Evaluation for Relief Request 1-ISl-20 Regarding Pressurizer Surge Line Weld Inspection (TAC No. MD5267)," dated August 29, 2007 (ML072280088)
5. NRC letter to TVA, "Watts Bar Nuclear Plant, Unit 1 -Relief Requests Nos. 1-ISl-16, 1-ISl-17, 1-ISl-18, and 1-ISl-19 Requesting Relief from the lnservice Inspection Program," dated October 27, 2006 (ML062480232)

CNL-16-135 E1-4 of 29 X. Tables Tablet -ASME Code Class t and 2 Welds with Limited Coverage (</=90%) XI. Attachments CD containing the drawings that support the relief request. CNL-16-135 E1-5 of 29 Table 1 ASME Code Class 1 and 2 Welds with Limited Coverage (</=90%) System I Materials Category I Dia./ Report Limited Component ID (Configuration)

Item No. Thickness Number Scan% Additional Information RPV I SA-S33 GR B Cl 1 I B-A I Bl.11 173" I R-P17SS 88% Automated underwater UT from ID. W02-03 SA-S08 Cl 2 S.392" Beam angle: Phased Array PA60° -80°L, (RPV Bottom Head-PA40° -S0°S, PA30° -60°L, & PAS0° L. UT to-Lower Shell exam limited by support lugs on the ID. Weld) NRI*. RPV I SA-S08 Cl 2 I B-A I Bl.40 173" I R-P1014 7S% Manual UT exam of RPV Head-to-Flange.

W08-09 SA-S08 Cl 2 7.30" Beam angle: 1) 0° longitudinal

2) 4S 0 shear (RPV Top-Head-to-and 3) 60° shear, Transducer Size: 1) 1", Flange Weld) 2) .S" x 1.0", and 3) .S" x 1.0" Limitations from the flange profile configuration and three lifting lugs (4.0" tall x S.9" length each and have a 12.8" arc length in contact with RPV head). NRI* (PT NRI*). RPV I SA-S08 Cl 2 I B-D I B3.90 31" I R-P1763 84% Automated underwater UT from ID. N-lS SA-S08 Cl 2 10.98" Beam angle: Phased Array PA60° -80°L, (RPV HL Nozzle-to-PA40° -S0°S, PA30° -60°L, PAS0° L, PAS 0 -Shell Weld at 22°) 40°L, & PA3S 0 -4S 0 S. UT exam limited due to the proximity of the nozzle integral extension.

NRI*. RPV I SA-S08 Cl 2 I B-D I B3.90 31" I R-P1766 84% Automated underwater UT from ID. N-16 SA-S08 Cl 2 10.98" Beam angle: Phased Array PA60° -80°L, (RPV HL Nozzle-to-PA40° -S0°S, PA30° -60°L, PAS0° L, PAS 0 -Shell Weld at 1S8°) 40°L, & PA3S 0 -4S 0 S. UT exam limited due to the proximity of the nozzle integral extension.

NRI*. CNL-16-135 E1-6 of 29 Table 1 ASME Code Class 1 and 2 Welds with Limited Coverage (</=90%) System I Materials Category I Dia./ Report Limited Component ID (Configuration)

Item No. Thickness Number. Scan% Additional Information RPV I SA-S08 Cl 2 I B-D I B3.90 31" I R-P17G7 83% Automated underwater UT from ID. N-17 SA-S08 Cl 2 10.98" Beam angle: Phased Array PAG0° -80°L, (RPV HL Nozzle-to-PA40° -S0°S, PA30° -G0°L, PAS0° L, PAS 0 -Shell Weld at 202°) 40°L, & PA3S 0 -4S 0 S. UT exam limited due to the proximity of the nozzle integral extension.

NRI*. RPV I SA-S08 Cl 2 I B-D I B3.90 31" I R-P1770 83% Automated underwater UT from ID. N-18 SA-S08 Cl 2 10.98" Beam angle: Phased Array PAG0° -80°L, (RPV HL Nozzle-to-PA40° -S0°S, PA30° -G0°L, PAS0° L, PA5° -Shell Weld at 338°) 40°L, & PA35° -45°S. UT exam limited due to the proximity of the nozzle integral extension.

NRI*. PZR/ SA-S33 GR A CL 2 I B-D I 14" I 3.3S" R-P1291 SG% Beam angle: o 0 L, 4S 0 S, and G0°S. WP-10 SA-508 CL 2 B3.110 Transducer Size: .75", .5", & .5". Manual UT (Surge Nozzle-to-exam limited due to nozzle configuration and Vessel Weld) heater penetrations.

NRI*. PZR/ SA-S33 GR A CL 2 / B-D I 4" I 2.8S" R-P1283 G9% Beam angle: o 0 L, 45°S, and G0°S. WP-11 SA-S08 CL 2 B3.110 Transducer Size: .7S", .S"xl", & .S"xl". (Spray Nozzle-to-Manual UT exam limited due to nozzle Vessel Weld) configuration.

NRI*. PZR I SA-533 GR A CL 2 I B-D I G" I 2.8S" R-P1282 G1% Beam angle: o 0 L, 4S 0 S, and G0°S. WP-12 SA-S08 CL 2 B3.110 Transducer Size: .7S", .S"xl", & .S"xl". (Relief Nozzle-to-Manual UT exam limited due to nozzle Vessel Weld) configuration.

NRI*. PZR/ SA-S33 GR A CL 2 / B-D I G" I 2.8S" R-P1284 S9% Beam angle: 0°L, 4S 0 S, and G0°S. WP-q SA-S08 CL 2 B3.110 Transducer Size: .7S", .S"xl", & .S"xl". (Safety Nozzle-to-Manual UT exam limited due to nozzle Vessel Weld) configuration.

NRI*. CNL-16-135 E1-7 of 29 Table 1 ASME Code Class 1 and 2 Welds with Limited Coverage (</=90%) System I Materials Category I Dia./ Report Limited Component ID (Configuration)

Item No. Thickness Number Scan% Additional Information PZR/ SA-533 GR A CL 2 I B-D I G" I 2.85" R-P1281 59% Beam angle: o 0 L, 45°S, and G0°S. WP-14 SA-508 CL 2 B3.110 Transducer Size: .75", .5"x1", & .5"x1". (Safety Nozzle-to-Manual UT exam limited due to nozzle Vessel Weld) configuration.

NRI*. PZR/ SA-533 GR A CL 2 I B-D I G" I 2.85" R-P1280 G1% Beam angle: 0°L, 45°S, and G0°S. WP-15 SA-508 CL 2 83.110 Transducer Size: .75", .5"x1", & .5"x1". (Safety Nozzle-to-Manual UT exam limited due to nozzle Vessel Weld) configuration.

NRI*. RCS I SA-21G GR WCC/ B-F / B5.70 28.94" ID I R-P2440 39% Beam angle: 45°L. Transducer Size: 1". RCF-El-2-SE SA-351 GR CF8A 2.33" Manual UT exam of Dissimilar Metal (DM) (SG# 1 HL Nozzle-weld (carbon steel to stainless steel) limited to-safe-end weld) due to nozzle configuration.

NRI*. (PT NRI*). No Alloy GOO material subjected to PWSCC. RCS I SA-21G GR WCC/ B-F I B5.70 27.44" ID I R-P2439 30% Beam angle: 45°L. Transducer Size: 1". RCF-G 1-1-SE SA-351 GR CF8A 2.21" Manual UT exam of Dissimilar Metal (DM) (SG# 1 CL Nozzle-weld (carbon steel-to stainless steel) limited to-safe-end weld) due to nozzle configuration.

NRI*. (PT NRI*). No Alloy GOO material subjected to PWSCC. RCS I SA-21G GR WCC/ B-F I B5.70 28.94" ID I R-P2442 27% Beam angle: 45°L. Transducer Size: 1". RCF-E2-2-SE SA-351 GR CF8A 2.33" Manual UT exam of Dissimilar Metal (DM) (SG# 2 HL Nozzle-weld (carbon steel to stainless steel) limited to-safe-end weld) due to nozzle configuration.

NRI*. (PT NRI*). No Alloy GOO material subjected to PWSCC. CNL-16-135 E1-8 of 29 Table 1 ASME Code Class 1 and 2 Welds with Limited Coverage (</=90%) System I Materials Category I Dia./ Report Limited Component ID (Configuration)

Item No. Thickness Number Scan% Additional Information RCS/ SA-216 GRWCC/ B-F I BS.70 27.44" ID I R-P2441 31% Beam angle: 45°L. Transducer Size: 1". RCF-G2-1-SE SA-351 GR CF8A 2.21" Manual UT exam of Dissimilar Metal (DM) (SG# 2 CL Nozzle-weld (carbon steel to stainless steel) limited to-safe-end weld) due to nozzle configuration.

NRI*. (PT Sat). No Alloy 600 material subjected to PWSCC. RCS/ SA-216 GR WCC/ B-F I B5.70 28.94" ID I R-P2443 26% Beam angle: 45°L. Transducer Size: 1". RCF-E3-2-SE SA-351 GRCF8A 2.33" Manual UT exam of Dissimilar Metal (OM) (SG# 3 HL Nozzle-weld (carbon steel to stainless steel) limited to-safe-end weld) due to nozzle configuration.

NRI*. (PT Sat). No Alloy 600 material subjected to PWSCC. RCS/ SA-216 GR WCC/ B-F I B5.70 27.44" ID I R-P2438 29% Beam angle: 45°L. Transducer Size: 1". RCF-G3-1-SE SA-351 GR CF8A 2.21" Manual UT exam of Dissimilar Metal (DM) (SG# 3 CL Nozzle-weld (carbon steel to stainless steel) limited to-safe-end weld) due to nozzle configuration.

NRI*. (PT Sat). No Alloy 600 material subjected to PWSCC. RCS I SA-216 GR WCC/ B-F I B5.70 28.94" ID I R-P2437 33% Beam angle: 45°L. Transducer Size: 1". RCF-E4-2-SE SA-351 GR CFBA 2.33" Manual UT exam of Dissimilar Metal (DM) (SG# 4 HL Nozzle-weld (carbon steel to stainless steel) limited to-safe-end weld) due to nozzle configuration.

NRI*. (PT NRI*). No Alloy 600 material subjected to PWSCC. RCS/ SA-216 GR WCC/ B-F I B5.70 27.44" ID I R-P2444 28% Beam angle: 45°L. Transducer Size: 1". RCF-G4-1-SE SA-351 GR CF8A 2.21" Manual UT exam of Dissimilar Metal (DM) (SG# 4 CL Nozzle-weld (carbon steel to stainless steel) limited to-safe-end weld) due to nozzle configuration.

NRI*. (PT -punch marks -Sat). No Alloy 6,00 material subjected to PWSCC. CNL-16-135 E1-9 of 29 Table 1 ASME Code Class 1 and 2 Welds with Limited Coverage (</=90%) System I Materials Category I Dia./ Report Limited Component ID (Configuration)

Item No. Thickness Number Scan% Additional Information RCS I SA-351 CF-BA B-J I B9.11 27.5" I R-P0147 75% Beam angle: 45° refracted longitudinal.

RCF-C2-2 (pipe and pump) 2.21" Transducer Size: .5"x1.0".

Limitation upstream due to pump housing configuration.

NRI* (PT NRI*). RCS I SA-351 CF-BA B-J I B9.11 27.5" I R-P0149 75% Beam angle: 45° refracted longitudinal RCF-C3-2 (pipe and pl.imp) 2.21" Transducer Size: .5"x1.0".

Limitation upstream due to pump housing configuration.

NRI* (PT NRI*). RCS/ SA-403 WP304 B-J I B9.11 4" I o.531" R-P022B 90% Beam angle: 1) 45° shear and 2) 70° shear. RCF-0145-05 (tee and reducer) Transducer Size: 1) .250" and 2) .250". Limitation due to tee and reducer configuration.

NRI* (PT NRI*). RCS I SA-403 WP304 / B-J I B9.11 4" I 0.531" R-P0226 50% Beam angle: 1) 45° shear and 2) 60° RCF-0145-0B SA-1B2 F316 refracted longitudinal.

Transducer Size: 1) (elbow/valve)

.250" and 2) dual Bx14mm. Limitation due to valve body taper. NRI* (PT NRI*). RCS/ SA-351 CF-BA B-J I 89.11 31" I 2.4B" R-P0152 75% Beam angle: 45° refracted longitudinal.

RCF-Gl-4 (pipe and pump) Transducer Size: .5"x1.0".

Limitation downstream due to pump housing configuration.

NRI* (PT NRI*). RCS/ SA-351 CF-BA B-J I B9.11 31" I 2.4B" R-P0156 75% Beam angle: 45° refracted longitudinal.

RCF-G2-4 (pipe and pump) Transducer Size: .5"x1.0".

Limitation downstream due to pump housing configuration.

NRI* (PT NRI*). CNL-16-135 E1-10 of 29 Table 1 ASME Code Class 1 and 2 Welds with Limited Coverage (</=90%) System I Materials Category I Dia./ Report Limited Component ID (Configuration)

Item No. Thickness Number Scan% Additional Information RCS/ SA-351 CF-BA B-J I B9.11 31" I 2.48" R-P0150 75% Beam angle: 45° refracted longitudinal.

RCF-G3-4 (pipe and pump) Transducer Size: .5"x1.0".

Limitation downstream due to pump housing configuration.

NRI* (PT NRI*). RCS/ SA-351 CF-BA B-J I B9.11 31" I 2.48" R-P0155 75% Beam angle: 45° refracted longitudinal.

RCF-G4-4 (pipe and pump) Transducer Size: .5"x1.0".

Limitation downstream due to pump housing configuration.

NRI* (PT NRI*). RCS/ SA-403 WP304 / B-J I B9.11 6" I R-P1359 75% Beam angle: 1) 45° shear and 2) 60° RCS-011 SA-182 F316 0.719"** refracted longitudinal.

Transducer Size: 1) (elbow/flange)

.375" and 2) dual 7x10mm. Limitation from flange side due to configuration.

NRI* (PT NRI*). RCS I SA-403 WP304 / B-J I B9.11 6" I R-P1364 75% Beam angle: 1) 45° shear and 2) 60° RCS-018 SA-182 F316 0.719"** refracted longitudinal.

Transducer Size: 1) (elbow/flange)

.375" and 2) dual 7x10mm. Limitation from flange side due to configuration.

NRI* (PT NRI*). CNL-16-135 E1-11 of 29 Table 1 ASME Code Class 1 and 2 Welds with Limited Coverage (</=90%) System I Materials Category I Dia./ Report Limited Component ID (Configuration)

Item No. Thickness Number Scan% Additional Information RV I SA-182 TP 304 / B-J I B9.11 4" I Beam angle: 2-085-W001-SA-403WP TP 304 0.67"** 1) 45° shear and or 316 2) 60° refracted longitudinal.

A5-1-0 (adapter/

cap) R-P1850 73% Transducer Size: 1) .375" and 2) dual 2-085-W001-E15-8x14mm. 1-0 R-P1851 74% Limitation from cap side due to configuration.

2-085-W001-NRI* (PT NRI*). L1-1-0 R-P1853 74% 2-085-W001-L15-1-0 R-P1852 74% 2-085-W001-R11-1-0 R-P1854 74% RCS/ SA-403 TP 316 I B-J I B9.11 6.28" I Beam angle:' 2-087B-W001-01 SA-182 TP 304 0.64"** R-P1842 73% 1) 45° shear and (cap/pipe)

2) 60° refracted longitudinal.

2-087B-W001-02 R-P1844 74% Transducer Size: 1) .375" and 2) dual 2-087B-W001-03 R-P1843 74%

Limitation from cap side due to 2-087B-W001-04 R-P1845 74% configuration.

NRI* (PT NRI*). RHRS/ SA-403 WP316 I B-J I B9.11 14" I R-P0689 76% Phased array 25° to 70° shear wave sector RHRF-0031-04 SA-182 F316 1.250" (16 element probe) and 40° to 70° refracted (tee/valve) longitudinal wave sector (15 element probe supplemental).

Limitation due to valve to tee configuration.

NRI* (PT NRI*). CNL-16-135 E1-12 of 29 Table 1 ASME Code Class 1 and 2 Welds with Limited Coverage (</=90%) System I Materials Category I Dia./ Report Limited Component ID (Configuration)

Item No. Thickness Number Scan% Additional Information RHRS/ SA-376 TP316 /SA-B-J I B9.11 14" I R-P0766 83% Phased array 25° to 70° shear wave sector RHRF-0031-13 182 F316 1.250" (16 element probe) and 40° to 70° refracted (pipe/valve) longitudinal wave sector (15 element probe supplemental).

Limitation from valve side due to configuration.

NRI* (PT NRI*). RHRS/ SA-403 WP316 I B-J I B9.11 10" I 1.00" R-P0767 90% Phased array 25° to 70° shear wave sector RHRF-0031-14 SA-182 F316 (16 element probe) and 40° to 70° refracted (elbow/valve) longitudinal wave sector (15 element probe supplemental).

Limitation due to valve to elbow configuration.

NRI* (PT NRI*). RHRS/ SA-182 F316 /SA-B-J I B9.11 6" I 0.719" R-P2479 26% Beam angle: 1) 45° shear and 2) 60° RHRF-0032-12 403 WP304 refracted longitudinal.

Transducer Size: 1) (valve/elbow)

.375" and 2) dual 10x18mm. Limitation due to valve to elbow configuration.

NRI* (PT NRI*). RHRS I SA-403 TP316 /SA-B-J I B9.11 10" I 1.00" R-P0759 88% Phased array 25° to 70° shear wave sector RHRS-015 403 WP316 (16 element probe). Limitation from tee side (pipe/tee) due to configuration.

NRI* (PT NRI*). SIS I SA-376 TP316 / SA-B-J I B9.11 10" I i.oo" R-P0437 68% Phased array 25° to 70° shear wave sector SIF-0196-03 182 F316 (16 element probe) and 40° to 70° refracted (pipe/valve) longitudinal wave sector (15 element probe supplemental).

Limitation from valve side due to configuration.

NRI* (PT NRI*) SIS I SA-376 TP316 / SA-B-J I B9.11 10" I 1.00" R-P0472 73% Beam angle: 1) 45° shear and 2) 70° SIF-0196-05 182 F316 refracted longitudinal.

Transducer Size: 1) (pipe/valve)

.375" and 2) dual 8x14mm. Limitation from valve side due to configuration.

NRI* (PT NRI*). CNL-16-135 E1-13 of 29 Table 1 ASME Code Class 1 and 2 Welds with Limited Coverage (</=90%) System I Materials Category I Dia./ Report Limited Component ID (Configuration)

Item No. Thickness Number Scan% Additional Information SIS I SA-403 WP316 I B-J I 89.11 10" I 1.00" R-P0486 75% Phased array 25° to70° shear wave sector SIF-0196-06 SA-182 F316 (16 element probe) and 40° to 70° refracted ( tee/va Ive) longitudinal wave sector (15 element probe supplemental).

Limitation due to valve to tee configuration.

NRI* (PT NRI*). SIS I SA-403 WP316 / B-J I 89.11 6" I 0.719" R-P0440 73% Beam angle: 1) 45° shear and 2) 70° SIF-0196-07 SA-182 F316 refracted longitudinal.

Transducer Size: 1) (elbow/valve)

.375" and 2) dual 8x14mm. Limitation from valve side due to configuration.

NRI* (PT NRI*). SIS I SA-376 TP316 / SA-B-J I 89.11 10" I 1.00" R-P0487 73% Phased array 25° to 70° shear wave sector SIF-0196-10 182 F316 (16 element probe) and 40° to 70° refracted (pipe/valve) longitudinal wave sector (15 element probe supplemental).

Limitation from valve side due to configuration.

NRI* (PT NRI*). SIS I SA-403 WP316 / B-J I 89.11 10" I 1.00" R-P0488 75% Phased array 25° to 70° shear wave sector SIF-0196-11 SA-182 F316 (16 element probe) and 40° to 70° refracted (elbow/valve) longitudinal wave sector (15 element probe supplemental).

Limitation from valve side due to configuration.

NRI* (PT NRI*). SIS I SA-376 TP316 I SA-B-J I 89.11 10" I 1.00" R-P0304 75% Phased array 25° to 70° shear wave sector SIF-0197-03 182 F316 (16 element probe) and 40° to 70° refracted (pipe/valve) longitudinal wave sector (15 element probe supplemental).

Limitation from valve side due to configuration.

NRI* (PT NRI*). CNL-16-135 E1-14 of 29 Table 1 ASME Code Class 1 and 2 Welds with Limited Coverage (</=90%) System I Materials Category I Dia. I Report Limited Component ID (Configuration)

Item No. Thickness Number Scan% Additional Information SIS I SA-376 TP316 I SA-B-J I B9.11 10" I 1.00" R-P2265 74% Beam angle: 1) 45° shear and 2) 60° SIF-0197-04 182 F316 refracted longitudinal.

Transducer Size: 1) (pipe/valve)

.5" and 2) dual 10x18mm. Limitation from valve side due to configuration.

NRI* (PT NRI*). SIS I SA-403 WP316 I B-J I B9.11 10" I 1.00" R-P0287 73% Beam angle: 1) 45° shear and 2) 70° SIF-0197-05 SA-182 F316 refracted longitudinal.

Transducer Size: 1) (tee/valve)

.375" and 2) dual 8x14mm. Limitation from valve side due to configuration.

NRI* (PT -1/8" recordable linear -Sat). ) SIS I SA-182 F316/ B-J I B9.11 6" I .719" R-P1812 69% Beam angle: 1) 45° shear and 2) 60° SIF-0197-06 SA-376 TP316 refracted longitudinal.

Transducer Size: 1) (valve/pipe)

.375" and 2) dual 10x18mm. Limitation from valve side due to configuration and coupling downstream.

NRI* (PT NRI*). SIS I SA-376 TP316 /SA-B-J I B9.11 10" I 1.00" R-P0306 74% Beam angle: 1) 45° shear and 2) 70° SIF-0197-08 182 F316 refracted longitudinal.

Transducer Size: 1) (pipe/valve)

.375" and 2) dual 8x14mm. Limitation from valve side due to configuration.

NRI* (PT NRI*). SIS I SA-403 WP316 I B-J I B9.11 10" I 1.00" R-P0305 74% Beam angle: 1) 45° shear and 2) 70° SIF-0197-09 SA-182 F316 refracted longitudinal.

Transducer Size: 1) (elbow/valve)

.375" and 2) dual 8x14mm. Limitation from valve side due to configuration.

NRI* (PT NRI*). CNL-16-135 E1-15 of 29 Table 1 ASME Code Class 1 and 2 Welds with Limited Coverage (</=90%) System I Materials Category I Dia./ Report Limited Component ID (Configuration)

Item No. Thickness Number Scan% Additional Information SIS I SA-376 TP316 /SA-B-J I 89.11 6" I .719" R-P2466 29% Beam angle: 1) 45° shear and 2) 60° SIF-0197-11 182 F316 refracted longitudinal.

Transducer Size: 1) (pipe/valve)

.25" and 2) dual 10x18mm. Limitation from valve side due to configuration.

NRI* (PT NRI*). SIS I SA-376 TP316 / SA-B-J I B9.11 6" I o.719" R-P0620 50% Phased array 25° to 70° shear wave sector SIF-D197-11A 182 F316 (16 element probe) and 40° to 70° refracted (pipe/valve) longitudinal wave sector (dual element probe). Limitation from valve side due to configuration.

NRI* (PT NRI*). SIS I SA-376 TP316 I SA-B-J I B9.11 10" I 1.00" R-P0348 75% Phased array 25° to 70° shear wave sector SIF-0198-03 182 F316 (16 element probe) and 40° to 70° refracted (pipe/valve) longitudinal wave sector (15 element probe supplemental).

Limitation from valve side due to configuration.

NRI* (PT NRI*). SIS I SA-376 TP316 I SA-B-J I B9.11 10" I 1.00" R-P0341 75% Beam angle: 1) 45° shear and 2) 70° SIF-0198-04 182 F316 refracted longitudinal.

Transducer Size: 1) (pipe/valve)

.375" and 2) dual 8x14mm. Limitation from valve side due to configuration.

NRI* (PT NRI*). SIS I SA-403 WP316 I B-J I B9.11 10" I 1.00" R-P0344 75% Beam angle: 1) 45° shear and 2) 70° SIF-0198-05 SA-182 F316 refracted longitudinal.

Transducer Size: 1) (tee/valve)

.375" and 2) dual 8x14mm. Limitation from valve side due to configuration.

NRI* (PT NRI*). CNL-16-135 E1-16 of 29 Table 1 ASME Code Class 1 and 2 Welds with Limited Coverage (</=90%) System I Materials Category I Dia./ Report Limited Component ID (Configuration)

Item No. Thickness Number Scan% Additional Information SIS I SA-403 WP316 I B-J I B9.11 6" I 0.719" R-P0349 75% Beam angle: 1) 45° shear and 2) 70° SIF-0198-06 SA-182 F316 refracted longitudinal.

Transducer Size: 1) (elbow/valve)

.375" and 2) dual 8x14mm. Limitation from valve side due to configuration.

NRI* (PT NRI*). SIS I SA-376 WP316 / B-J I B9.11 10" I R-P1819 50% Beam angle: 1) 45° shear and 2) 60° SIF-0198-09 SA-182 F316 1.000" refracted longitudinal.

Transducer Size: 1) (pipe/valve)

.375" and 2) dual 10x18mm. Limitation from valve side due to configuration.

NRI* (PT NRI*). SIS I SA-403 WP316 / B-J I B9.11 10" I 1.00" R-P0343 75% Beam angle: 1) 45° shear and 2) 60° SIF-0198-10 SA-182 F316 refracted longitudinal.

Transducer Size: 1) (elbow/valve)

.375" and 2) dual 8x14mm. Limitation from valve side due to configuration.

NRI* (PT NRI*). SIS I SA-403 WP316 / B-J I B9.11 10" I 1.00" R-P0434 57% Beam angle: 1) 45° shear and 2) 70° SIF-0199-03 SA-182 F316 refracted longitudinal.

Transducer Size: 1) (elbow/valve)

.375" and 2) dual 8x14mm. Limitation from valve side due to configuration.

NRI* (PT NRI*). SIS I SA-376 TP316 I SA-B-J I B9.11 10" I 1.00" R-P0369 74% Phased array 25° to 70° shear wave sector SIF-0199-05 182 F316 (16 element probe) and 40° to 70° refracted (pipe/valve) longitudinal wave sector (15 element probe supplemental).

Limitation from valve side due to configuration.

Recordable root geometry 360° at varying amplitude. (PT NRI*). CNL-16-135 E1-17 of 29 Table 1 ASME Code Class 1 and 2 Welds with Limited Coverage (</=90%) System I Materials Category I Dia./ Report Limited Component ID (Configuration)

Item No. Thickness Number Scan% Additional Information SIS I SA-403 WP316 I B-J I B9.11 10" I 1.00" R-P0370 75% Phased array 25° to 70° shear wave sector SIF-0199-06 SA-182 F316 (16 element probe) and 40° to 70° refracted (tee/valve) longitudinal wave sector (15 element probe supplemental).

Limitation from valve side due to configuration.

Recordable root geometry 360° at varying amplitude. (PT NRI*). SIS I SA-403 WP316 I B-J I B9.11 6" I 0.719" R-P0405 70% Manual UT limited from valve side due to SIF-0199-07 SA-182 F316 configuration. (elbow/valve)

Beam angle: 1) 45° shear and 2) 70° refracted longitudinal.

Transducer Size: 1) .375" and 2) dual 8x14mm. NRI* (PT NRI*). SIS I SA-376 TP316 /SA-B-J I 89.11 10" I 1.00" R-P0382 73% Phased array 25° to 70° shear wave sector SIF-0199-10 182 F316 (16 element probe) and 40° to 70° refracted (pipe/valve) longitudinal wave sector (15 element probe supplemental).

Limitation from valve side due to configuration.

NRI* (PT NRI*). SIS I SA-403 WP316 I B-J I B9.11 10" I 1.00" R-P0383 73% Phased array 25° to 70° shear wave sector SIF-0199-11 SA-182 F316 (16 element probe) and 40° to 70° refracted (elbow/valve) longitudinal wave sector (15 element probe supplemental). Limitation from valve side due to configuration.

NRI* (PT NRI*). SIS I SA-403 WP316 B-J I B9.11 6" I o.719" R-P0491 61% Phased array 25° to 70° shear wave sector SIF-0199-15 (tee and elbow) (16 element probe) and 40° to 70° refracted longitudinal wave sector (15 element probe supplemental).

Limitation from tee side due to configuration.

NRI* (PT NRI*). CNL-16-135 E1-18 of 29 Table 1 ASME Code Class 1 and 2 Welds with Limited Coverage (</=90%) System I Materials Category I Dia./ Report Limited Component ID (Configuration)

Item No. Thickness Number Scan% Additional Information RCS/ SA-182 TP 304 I B-J I B9.11 27.44" ID I R-P1788 50% Automated underwater UT Beam Angle PA RCF-C4-1 SA-351 GR CF8A 2.21" 60°-88° from ID. Scanned 100% of (RPV CL Nozzle examination area. However, no examination safe end-to-pipe at credit is taken for the cast stainless-steel side 67°, of the weld. Nozzle N-11) NRI* (PT NRI*). RCS/ SA-182 TP 304 I B-J I B9.11 27.44" ID I R-P1789 50% Automated underwater UT Beam Angle PA RCF-C3-1 SA-351 GR CF8A 2.21" 60°-88° from ID. Scanned 100% of (RPV CL Nozzle examination area. However, no examination safe end-to-pipe at credit is taken for the cast stainless-steel side 113°, of the weld. Nozzle N-12) NRI* (PT NRI*). RCS I SA-182 TP 304 / B-J I B9.11 27.44" ID I R-P1792 50% Automated underwater UT Beam Angle PA RCF-C2-1 SA-351 GR CF8A 2.21" 60°-88° from ID. Scanned 100% of (RPV CL Nozzle examination area. However, no examination safe end-to-pipe at credit is taken for the cast stainless-steel side 247°, of the weld. Nozzle N-13) NRI* (PT NRI*). RCS I SA-182 TP 304 I B-J I B9.11 27.44" ID I R-P1793 50% Automated underwater UT Beam Angle PA RCF-Cl-1 SA-351 GR CF8A 2.21" 60°-88° from ID. Scanned 100% of (RPV CL Nozzle examination area. However, no examination safe end-to-pipe at credit is taken for the cast stainless-steel side 293°, of the weld. Nozzle N-14) NRI* (PT NRI*). RCS I SA-351 GR CF8M/ B-J I B9.11 27.5" ID I R-P1469 75% Manual UT limited from pump side due to RCF-Cl-2 SA-351 GR CFBA 2.21" configuration. (Pump I Pipe) Beam angle: 45° refracted longitudinal.

Transducer Size: .5"x1.0".

NRI* (PT NRI*). CNL-16-135 E1-19of29 Table 1 ASME Code Class 1 and 2 Welds with Limited Coverage (</=90%) System I Materials Category I Dia./ Report Limited Component ID (Configuration)

Item No. Thickness Number Scan% Additional Information RCS I SA-351 GR CFSM/ B-J I B9.11 27.5" ID I R-P1367 62% Manual UT exam limited from pump side due RCF-C4-2 SA-351 GR CFSA 2.21" to configuration. (Pump I Pipe) Beam angle: 45c refracted longitudinal.

Transducer Size: .5"x1.0".

NRI* (PT NRI*). RCS I SA-376 TP 304 I B-J I B9.11 4" I R-P132S 50% Manual UT exam limited from valve side due RCF-0145-03 SA-403 WP 304 0.531" to configuration. (Pipe I Valve) Beam Angle: 1) Phased Array, 2.0 MHZ, S element probe with a 25c to 70c shear wave / display. 2) 1.5 MHZ dual 15 element probe with a 25c to 70c shear wave display. NRI* (PT NRI*). RCS/ SA-376 TP 304 I B-J I B9.11 4" I R-P1329 50% Manual UT exam limited from valve side due RCF-0145-04 SA-403 WP 304 0.531" to configuration. (Valve / Elbow) Beam Angle: 1) Phased Array, 2.0 MHZ, S element probe with a 25c to 70c shear wave display. 2) 1.5 MHZ dual 15 element probe with a 25c to 70c shear wave display. NRI* (PT NRI*). RCS I SA-376 TP 304 I B-J I B9.11 4" I R-P2044 75% Manual UT exam limited from valve side due RCF-0145-09 SA-403 WP 304 0.531" to configuration. (Valve / Pipe) Beam angle: 1) 45c shear and 2) 60c refracted longitudinal.

Transducer Size: 1) .25" and 2) dual Sx14mm. NRI* (PT NRI*). SIS I SA-376 TP304 I SA-B-J I B9.22 1.5" I R-P0590 50% Phased array 35c to soc shear wave sector (S SIF-B-T076-06 1S2 F316 0.2S1" element probe). Limitation from flange side (pipe/flange) configuration NRI* (UT only). SIS I SA-376 TP304 /SA-B-J I B9.22 1.5" I R-P0591 50% Phased array 35c to soc shear wave sector (S SIF-B-T076-23 1S2 F316 0.2S1" element probe). Limitation from flange side (pipe/flange) configuration NRI* (UT only). CNL-16-135 E1-20 of 29 Table 1 ASME Code Class 1 and 2 Welds with Limited Coverage (</=90%) System I Materials Category I Dia./ Report Limited Component ID (Configuration)

Item No. Thickness Number Scan% Additional Information SIS I SA-376 TP304 I 8-J I 89.22 1.5" I R-P0650 75% Phased array 35° to 80° shear wave sector (8 SIF-8-T077-01 SA-403 WP304 0.281" element probe). Limitation from tee side (pipe/tee) configuration.

NRI* (UT only). SIS I SA-376 TP304 I SA-8-J I 89.22 1.5"/ R-P0588 50% Phased array 35° to 70° circ/80° axial shear SIF-8-T095-01 182 F316 0.281" wave sector (8 element probe). Limitation (pipe/nozzle) from nozzle side configuration.

NRI* (UT only). SIS I SA-182 F316 I 8-J I 89.22 1.5" I R-P2473 50% Manual UT using 45° and 70° shear waves. SIF-8-T097-12 SA-376 TP304 0.281" Limitation from flange side configuration. (flange/pipe)

NRI* (UT only). SIS I SA-376 TP304 / SA-8-J I 89.22 1.5" I R-P2474 50% Manual UT using 45° and 70° shear waves. SIF-8-T097-13 182 F316 0.281" Limitation from flange side configuration. (pipe/flange)

NRI* (UT only). SIS I SA-376 TP304 I SA-8-J I 89.22 1.5" I R-P0646 50% Phased array 35° to 80° shear wave sector (8 SIF-8-T107-04 182 F316 0.281" element probe). Limitation from flange side (pipe/flange) configuration.

NRI* (UT only). SIS I SA-376 TP304 I SA-8-J I 89.22 1.5" I R-P2475 50% Manual UT using 45° and 70° shear waves. SIF-8-T107-05 182 F316 0.281" Limitation from flange side configuration. (pipe/flange)

NRI* (UT only). SIS I SA-376 TP304 /SA-8-J I 89.22 1.5" I R-P0647 75% Phased array 35° to 80° shear wave sector (8 SIF-8-T107-26 182 F316 0.281" element probe). Limitation from nozzle side (pipe/nozzle) configuration.

NRI* (UT only). SIS I SA-376 TP304 /SA-8-J I 89.22 1.5" I R-P0651 49% Phased array 35° to 80° shear wave sector (8 SIF-8-T142-01 182 F316 0.281" element probe). Limitation from nozzle side (pipe/nozzle) configuration.

NRI* (UT only). CNL-16-135 E1-21 of 29 Table 1 ASME Code Class 1 and 2 Welds with Limited Coverage (</=90%) System I Materials Category I Dia./ Report Limited Component ID (Configuration)

Item No. Thickness Number Scan% Additional Information SIS I SA-182 F316 I SA-B-J I B9.22 1.5" I R-P2476 50% Beam angle: 1) 45° shear and 2) 70° shear. SIF-B-Tl 42-24 376 TP 304 0.281" Transducer Size: 1) .25" and (flange/pipe)

2) .25". Limitation from flange side due to configuration.

NRI* (UT only). SIS I SA-376 TP 304 I B-J I B9.22 1.5" I R-P2477 50% Beam angle: 1) 45° shear and 2) 70° shear. SIF-B-Tl 42-25 SA-182 F316 0.281" Transducer Size: 1) .25" and (pipe/flange)

2) .25". Limitation from flange side due to configuration.

NRI* (UT only). SIS I SA-376 TP304 /SA-B-J I B9.22 1.5" I R-P0648 71% Phased array 35° to 80° shear wave sector (8 SIF-B-T154-01 182 F316 0.281" element probe). Limitation from nozzle side (pipe/nozzle) configuration.

NRI* (UT only). SIS I SA-376 TP304 / SA-B-J I B9.22 3" I 0.281" R-P0508 70% Beam angle: 1) 45° shear and 2) 70° shear. SIF-0193-03 182 F316 Transducer Size: 1) .250" and 2) .250". (pipe/valve)

Limitation from valve side due to configuration.

NRI* (UT only). SIS I SA-376 TP304 /SA-B-J I B9.22 2.5" I R-P2075 50% Beam angle: 1) 45° shear and 2) 70° shear. SIF-0193-08 403 WP 304 0.375" Transducer Size: 1) .250" and 2) .250". (pipe/flange)

Limitation from flange side due to configuration.

NRI* (UT only). SIS I SA-403 WP 304/ B-J I 89.22 2.5" I R-P2077 50% Beam angle: 1) 45° shear and 2) 70° shear. SIF-0193-13 SA-376 TP304 0.375" Transducer Size: 1) .250" and 2) .250". (flange/pipe)

Limitation from flange side due to configuration.

NRI* (UT only). RCS/ SA-351 CF-SA/ SA-B-J I B9.31 6" I R-P0101 50% Beam angle: 45° refracted longitudinal.

RCS-1-6 182 F316 2.33"** Transducer Size: .5"x1.0".

Limitation from (pipe/branch).

branch connection side due to configuration.

NRI* (PT NRI*). CNL-16-135 E1-22 of 29 Table 1 ASME Code Class 1 and 2 Welds with Limited Coverage (</=90%) System I Materials Category I Dia./ Report Limited Component ID (Configuration)

Item No. Thickness Number Scan% Additional Information RCS/ SA-351 CF-BA/ SA-B-J I B9.31 6" I R-P0105 50% Beam angle: 45° refracted longitudinal.

RCS-2-6 1B2 F316 2.33"** Transducer Size: .5"x1.0".

Limitation from (pipe/branch) branch connection side due to configuration.

NRI* (PT NRI*). RCS I SA-351 CF-BA / SA-B-J I B9.31 6" I R-P0106 50% Beam angle: 45° refracted longitudinal.

RCS-3-6 1B2 F316 2.33"** Transducer Size: .5"x1.0".

Limitation from (pipe/branch) branch connection side due to configuration.

NRI* (PT NRI*). RCS/ SA-351 CF-BA/ SA-B-J I B9.31 14" I R-P1349 B4% Beam angle: 45° refracted longitudinal.

RCS-4-6 403 WP316 2.33"** Transducer Size: .5"x1.0".

Limitation from (pipe/branch) branch connection side due to configuration.

NRI* (PT NRI*). RCS/ SA-376 TP 316/ B-J I 89.31 14" I R-P1460 6B% Beam angle: 45° refracted longitudinal.

RCS-P-1 SA-351 CF-BA 2.33"** Transducer Size: .5"x1.0".

Limitation from (pipe/branch) branch connection side due to configuration.

NRI* (PT NRI*). RCS/ SA-351 CF-BA/ SA-B-J I B9.31 4" I R-P0107 46% Beam angle: 1) 45° shear and 2) 60° RCW-01 182 F316 2.21"** refracted longitudinal.

Transducer Size: 1) (pipe/branch)

.375" and 2) dual 8x14mm. Limitation from branch side due to configuration.

NRI* (PT NRI*). RCS/ SA-351 CF-BA/ SA-B-J I B9.31 4" I R-P010B 41% Beam angle: 1) 45° shear and 2) 60° RCW-02 1B2 F316 2.21"** refracted longitudinal.

Transducer Size: 1) (pipe/branch)

.375" and 2) dual Bx14mm. Limitation from branch side due to configuration.

NRI* (PT NRI*). CNL-16-135 E1-23 of 29 Table 1 ASME Code Class 1 and 2 Welds with Limited Coverage (</=90%) System I Materials Category I Dia./ Report Limited Component ID (Configuration)

Item No. Thickness Number Scan% Additional Information BIT Tank/ SA-351 CFBA / SA-C-A I Cl.20 53" I R-P2183 61% Manual UT exam limited by component 240 TP 304 r configuration and material.

BIT-2 (Shell/Head Weld) 2.0" HD, Beam angle: 1) 0°L, 2) 45° shear, 3) 60° 3.12" SH shear and 4) 60° RL. Transducer Size: 1) .75", 2) .5", 3) .5", and 4) dual 15x25mm. NRI*. BIT Tank/ SA-351 CFBA /SA-C-A I Cl.20 53" I R-P2184 61% Manual UT exam limited by component BIT-3 240 TP 304 2.0" HD, configuration and material. (Shell/Head Weld) Beam angle: 1) 0°L, 2) 45° shear, 3) 60° 3.12" SH shear and 4) 60° RL. Transducer Size: 1) .75", 2) .5", 3) .5", and 4) dual 15x25mm. NRI*. RHRHX/ SA-240 TP304/ C-A I Cl.20 37" I 1.00" R-P1379 73% Manual UT exam limited by integral RHRHX-1-2B SA-240 TP304 attachments and nozzles. (Shell/Head)

Beam angle: 1) 45° shear, and 2) 60° refracted longitudinal.*

Transducer Size: 1) .5", 2) dual 10x18mm. NRI*. RHRHX/ SA-240 TP304/ C-A I Cl.20 37" I 1.00" R-P1378 75% Manual UT exam limited by integral RHRHX-2-2B SA-240 TP304 attachments and nozzles. (Shell/Flange)

Beam angle: 1) 45° shear, and 2) 60° refracted longitudinal.

Transducer Size: 1) .5", 2) dual 10x18mm. NRI*. Seal Water SA-240 TP304/ SA-. C-A I Cl.20 4" I 0.674" R-P2373 77% Manual UT exam limited by component Injection Filter/ 182 F304 configuration.

SWIFLTR-62-96 (Shell/Head)

Beam angle: 1) 45° shear, and 2) 60° refracted longitudinal.

Transducer Size: 1) .25", 2) dual 8x14mm. NRI*. CNL-16-135 E1-24 of 29 Table 1 ASME Code Class 1 and 2 Welds with Limited Coverage (</=90%) System I Materials Category I Dia. I Report Limited Component ID (Configuration)

Item No. Thickness Number Scan% Additional Information Steam Generator SA-508 CL 2/ C-A I C1.30 135" I R-P2455 89% Manual UT exam limited by component

  1. 2/ SA-533 Gr A CL 2 3.35" configuration.

SG-2-3-2 (tubesheet

/ shell) Beam angle: 1) 0°L, 2) 45°S, & 3) 60° S. Transducer Size: 1) .1", 2) .5"x1", and 3) .5"x1". NRI*. BIT Tank/ SA-182 TP 304 I . C-B I C2.21 6" I 2.0" R-P2182 75% Manual UT exam limited by component BIT-1 SA-240 TP 304 configuration. (Nozzle/ Beam angle: 1) 0°L, 2) 45° shear, and 3) 60° Bottom Head Weld) RL. Transducer Size: 1) .75", 2) .5", and 3) dual 15x25mm. NRI*. BIT Tank/ SA-182 TP 304 I C-B I C2.21 6" I 2.0" R-P2185 75% Manual UT exam limited by component BIT-4 SA-240 TP 304 configuration. (Nozzle I Top Head Beam angle: 1) 0°L, 2) 45° shear, and 3) 60° Weld) RL. Transducer Size: 1) .75", 2) .5", and 3) dual 15x25mm. NRI*. BIT Tank I SA-240 TP 304/ SA-C-C I C3.10 53" I R-P2148 77% Manual PT exams are limited due to BIT-5-IA 351 CF8A 0.625" R-P2147 77% component configuration.

The 4 support legs (Integral cover portions of the support pads, which are BIT-6-IA Attachment Pads R-P2146 77% welded to the vessel shell. BIT-7-IA to Shell Welds) R-P2145 77% BIT-8-IA eves I Centrifugal SA-240 TP 304 I c-c I C3.30 18" I 1" R-P3950 75% Manual PT exams are limited due to Charging Pumps SA-182 F304 21.6" /1" component configuration.

Four pump (CCPs) (Integral supports, two located on smaller diameter, CCPH-2B-B-IA Attachments to and two located on larger diameter of pump Casing Welds) casings. CNL-16-135 E1-25 of 29 Table 1 ASME Code Class 1 and 2 Welds with Limited Coverage (</=90%) System I Materials Category I Dia./ Report Limited Component ID (Configuration)

Item No. Thickness Number Scan% Additional Information RHRS I SA-403 WP 304/ C-F-1 I 8" I 0.906" R-P0930 89% Beam Angle: 1) Phased Array, 1.5 MHZ, 16 RHRF-0033-01 SA-376 TP 304 C5.11 element probe with a 20° to 70° shear wave (tee/pipe) display. 2) PA 1.5 MHZ dual 15 element probe with a 40° to 70° shear wave display. Limitation from tee side due to configuration.

NRI* (PT NRI*). SIS/ SA-403 WP 304/ C-F-1 I 14" I R-P2472 50% Manual UT exam limited by component SIF-0123-05 SA-403 F 304 C5.11 0.500" configuration. (valve/elbow)

Beam angle: 1) 45° shear, and 2) 60° refracted longitudinal.

Transducer Size: 1) .375", 2) dual 8x14mm. NRI*. SIS I SA-376 TP 316/ SA-C-F-1 I 8" I 0.906" R-P1180 75% Manual UT exam limited by component SIF-0194-15 403 WP 316 C5.11 configuration. (pipe/tee)

Beam angle: 1) 45° shear, and 2) 60° refracted longitudinal.

Transducer Size: 1) .375", 2) dual 8x14mm. NRI*. SIS I SA-403 WP 316/ C-F-1 I 6" I 0.719" R-P1132 74% Manual UT exam limited by component SIF-0195-13 SA-403 WP 316 C5.11 configuration. (elbow/valve)

Beam angle: 1) 45° shear, and 2) 70° refracted longitudinal.

Transducer Size: 1) .375", 2) dual 7x10mm. NRI*. CVCS/ SA-312 TP 304/ C-F-1 I 8" I o.322" R-P1519 75% Manual UT exam limited by component CVCF-0007-12 SA-403 WP304 C5.11 configuration. (pipe/valve)

Beam angle: 1) 45° shear, and 2) 70° shear. Transducer Size: 1) .25", 2) .25". NRI*. CVCS/ SA-376 TP 304/ SA-C-F-1 I 2" I o.343" R-P1590 73% Manual UT exam limited by component CVCF-A-T122-40 182 F 304 C5.21 configuration. (pipe/flange)

Beam angle: 1) 45° shear, 2) 70° shear. Transducer Size: 1) .25", 2) .25". NRI*. CNL-16-135 E1-26 of 29 Table 1 ASME Code Class 1 and 2 Welds with Limited Coverage (</=90%) System I Materials Category I Dia./ Report Limited Component ID (Configuration)

Item No. Thickness Number Scan% Additional Information CVCS/ SA-1S2 F 304/ SA-C-F-1 I 2" I o.343" R-P1591 73% Manual UT exam limited by component CVCF-A-T122-41 376 TP 304 C5.21 configuration. (flange/pipe)

Beam angle: 1) 45c shear, and 2) 70c shear. Transducer Size: 1) .25", 2) .25". NRI*. CVCS/ SA-312 TP 304/ SA-C-F-1 I 4" I o.237" R-P1592 75% Manual UT exam limited_ by component CVCF-0011-01 403 WP 304 C5.21 configuration. (pipe/penetration)

Beam angle: 1) 45c shear, and 2) 70c shear. Transducer Size: 1) .25", 2) .25". NRI*. SIS I SA-1S2 F 316/ SA-C-F-1 I 2" I o.343" R-P1107 75% Manual UT exam limited by component SIF-B-T071-0S 376 TP 304 C5.21 configuration. (flange/pipe)

Beam angle: 1) 45c shear, and 2) 70c shear. Transducer Size: 1) .25", 2) .25". Root geometry recorded only. SIS I SA-376 TP 304/ SA-C-F-1 I 2" I o.343" R-P1106 75% Manual UT exam limited by component SIF-B-T071-09 1S2 F 316 C5.21 configuration. (pipe/flange)

Beam angle: 1) 45c shear, and 2) 70c shear. Transducer Size: 1) .25", 2) .25". NRI*. SIS I SA-376 TP 304/ SA-C-F-1 I 2" I o.343" R-P1116 75% Manual UT exam limited from flange side due SIF-B-T090-06 1S2 F 316 C5.21 to configuration. (pipe/flange)

Beam Angle: 1) Phased Array, 2.0 MHZ, S element probe with a 35c to soc shear wave display. NRI* (PT NRI*). SIS I SA-1S2 F 316/ SA-C-F-1 I 2" I o.343" R-P1117 75% Manual UT exam limited from flange side due SIF-B-T090-07 376 TP 304 C5.21 to configuration. (flange/pipe)

Beam Angle: 1) Phased Array, 2.0 MHZ, S element probe with a 35c to sac shear wave display. NRI* (PT NRI*). CNL-16-135 E1-27 of 29 Table 1 ASME Code Class 1 and 2 Welds with Limited Coverage (</=90%) System I Materials Category I Dia./ Report Limited Component ID (Configuration)

Item No. Thickness Number Scan% Additional Information SIS I SA-182 F 304/ SA-C-F-1 I 3" I 0.300" R-P1133 75% Manual UT exam limited by component SIF-0116-010 403 WP 304 C5.21 configuration. (flange/elbow)

Beam angle: 1) 45° shear, and 2) 70° shear. Transducer Size: 1) .25", 2) .25". NRI*. SIS/ SA-403 WP 304/ C-F-1 I 4" I 0.337" R-P1079 86% Manual UT exam limited by component SIF-0116-06 SA-312 TP 304 C5.21 configuration. (tee/pipe)

Beam angle: 1) 45° shear, and 2) 60° shear. Transducer Size: 1) .25", 2) .25". NRI*. SIS I SA-403 WP 304/ C-F-1 I 4" I 0.531" R-P1129 75% Manual UT exam limited by component SIF-0118-02 SA-403 WP 304 C5.21 configuration. (elbow/valve)

Beam angle: 1) 45° shear, & 2) 60° RL. Transducer Size: 1) .25", 2) 4x8mm. NRI*. SIS/ SA-376 TP 304/ SA-C-F-1 I 4" I 0.531" R-P1162 75% Manual UT exam limited by component SIF-0118-13A 403 WP 304 C5.21 configuration. (pipe/flange)

Beam angle: 1) 45° shear, & 2) 60° RL. Transducer Size: 1) .25", 2) 4x8mm. NRI*. SIS I SA-403 WP 304/ C-F-1 I 4" I 0.237" R-P1161 75% Manual UT exam limited by component SIF-0119-03 SA-312 TP 304 C5.21 configuration. (valve/pipe)

Beam angle: 1) 45° shear, and 2) 70° shear. Transducer Size: 1) .25", 2) .25". NRI*. SIS I SA-403 WP 304/ C-F-1 I 4" I 0.237" R-P1163 75% Manual UT exam limited by component SIF-0120-10 SA-182 F 304 C5.21 configuration. (elbow/flange)

Beam angle: 1) 45° shear, & 2) 60° RL. Transducer Size: 1) .25", 2) 4x8mm. NRI*. FWS/ SA-420 WPL-6/ SA-C-F-2 I 6" I 0.432" R-P1429 84% Manual UT exam limited by component FWF-0212-04 420 WPL-6 C5.51 configuration. (valve/elbow)

Beam angle: 1) 45° shear, and 2) 60° shear. Transducer Size: 1) .375", 2) .375". NRI*. CNL-16-135 E1-28 of 29 _____________________________________________

__J Table 1 ASME Code Class 1 and 2 Welds with Limited Coverage (</=90%) System I Materials Category I Dia./ Report Component ID (Configuration)

Item No. Thickness Number FWS/ SA-420 WPL-6/ SA-C-F-2 I 6" I 0.432" R-P1426 FWF-0213-03 420 WPL-6 C5.51 (valve/elbow)

  • NRI: No Recordable Indications
    • Nominal wall thickness is given from the piping side of a branch connection PA: Phased Array ultrasonic beams L: Longitudinal wave ultrasonic beam RL: Refracted Longitudinal ultrasonic beam S: Shear Wave ultrasonic beam CNL-16-135 E1-29 of 29 Limited Scan% Additional Information 82% Manual UT exam limited by component configuration.

Beam angle: 1) 45° shear, and 2) 60° shear. Transducer Size: 1) .375", 2) .375". NRI*.