ML17266A199

From kanterella
Revision as of 06:48, 24 February 2018 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
LER 80-014/03L-0: on 800324,W/Reactor Shutdown for Refueling,6B2 Heater for Sbvs Discovered to Be Inoperable. Caused by Defective Thermocouple Amplifier (Fenwal Model 543) in 6B2 Heater Control Circuitry.Amplifier Replaced
ML17266A199
Person / Time
Site: Saint Lucie NextEra Energy icon.png
Issue date: 04/23/1980
Revision: 0
From: SHOPPMAN M
FLORIDA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML17208A556 List:
References
LER-80-014-03L, LER-80-14-3L, NUDOCS 8005080467
Download: ML17266A199 (2)