Errata & Addenda Sheet 7,replacing Pages 4-11 & 4-14 to LOCA Analysis Rept for Dresden Units 2 & 3 & Quad Cities 1 & 2 Nuclear Power Stations
ML20063C487
Person / Time
Site: Dresden, Quad Cities, 05000000
Issue date: 07/31/1982
From:
GENERAL ELECTRIC CO.
To:
Shared Package
ML20063C409 List:
References
79NED273, NEDO-24146A-ERR, NEDO-24246A-ERR-07, NEDO-24246A-ERR-7, NUDOCS 8208270273
Download: ML20063C487 (5)


Text

, ______._.__..______._

- , ATTACHMENT 2 NUCLEAR ENERGY BUSINESS GROUP

  • GENERAL ELECTRIC COMPANY SAN JOSE, CALIFORNIA 95125 GENER AL h ELECTRIC APPLICABLE TO:

~

^

l PU8LICATION NO 79NED273 ERRATA And ADDENDA 7 ,, ,. uo.

OR TITLE y DRESDEN UNITS 2, 3 AND QUAD July 1982 CITIES 1,2 NUCLEAR POWER STATIONS NOTE: Correct all copies of the applicable

\SSUE OATE AP Ul l9I publication as specified below.

REFERENCES INSTRUCTIONS P RAG APH N E) (CORRECTIONS AND ADDITIONS)

1. Page 4-11 Replace with new page 4-11,
2. Page 4-14, Replace with new page 4-14.

PAGE I Of 1 9209270273 820019 PDR ADOCK 05000254 P PI)R l

NEDO-24146A i

Table 4I MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE PLANT: Dresden 2,3/ Quad Cities 1,2 FUEL TYPE: P8DRB282 Average Planar Exposure MAPLHGR PCT Oxidation (mwd / t) (kW/ft) (*F) Fraction 200 11.2 2132 0.029 1,000 11.2 2132 0.029 5,000 11.S 2183 0.033 10,000 12.0 2189 0.032 15,000 12.0 2199 0.033 20,000 11.8 2181 0.032 25,000 11.3 2110 0.025 30,000 11.1 2075 0.043 35,000 10.4 1981 0.035 40,000 9.8 1886 0.021 ,

NOTE: Credit taken for the effects of pre-pressurization of the fuel rods Table 4J MAPLHCR VERSUS AVERAGE PLANAR EXPOSURE PLANT: Dresden 2,3/ Quad Cities 1,2 FUEL TYPE: P8DRB265H Average Planar Exposure MAPLHGR PCT 0xidation (mwd /t) (kW/ft) (*F) Fraction 200 11.5 2163 0.032 1,000 11.6 2171 0.032 5,000 11.9 1197 0.033 10,000 12.1 2198 0.033 15,000 12.1 2200 0.033 20,000 11.9 2190 0.032 25,000 11.3 2116 0.026 30,000 10.7 2018 0.018 35,000 10.2 1934 0.022 40,000 9.6 1835 0.009 ,

NOTE: Same as Table 4I 4-11 a

r ,

e'- '

o, NED0-24146A ,

Table 4K MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE-PLANT: Dresden 2,3/ Quad Cities 1,2 FUEL TYPE. P8DRB239 Average Planar Exposure MAPLHGR PCT 0xidation (mwd /t) (kW/ft) (*F) Fraction 200 11.3 2117 0.027 1,000 11.4 2129 0.028 5,000 11.7 2160 0.030 10,000 11.8 2141 0.028 15,000 11.8 2145 0.028 20,000 11.4 2114 0.025 25,000 10.9 2041 0.020 30,000 10.4 1968 0.015 NOTE: Same as Table 4I

~

Table 4L MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE PLANT: Quad Cities 2 FUEL TYPE: P8DGB284 (Barrier Fuel)

Average Planar Exposure MAPLHGR PCT 0xidation (mwd /t) (kW/ft) (*F) Fraction 200 11.5 2152 0.031 1,000 11.5 2150 0.030 5,000 11.9 2185 0.033 10,000 12.0 2189 0.032 15,000 12.1 2199 0.033 20,000 11.9 2180 0.032 25,000 11.3 2109 0.025 30,000 10.9 2042 0.020 35,000 10.3 1956 0.030 40,000 9.7 1846 0.010

~

NOTE: Same as Table 41 4-12

z l g NEDO-24146A

~

Table 4M MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE PIANT: Quad Cities 2 FUEL TYPE: P8DGB263L (Barrier Fuel) l Average Planar Exposure MAPLHGR PCT 0xidation (mwd /t) (kW/ft) ( F) Fraction 200 10.2 1991 0.018 1,000 10.3 2003 0.018 5,000 11.5 2133 0.027 10,000 12.0 2185 0.032 l 15,000 12.1 2199 0.03?

20,000 11.9 2187 0.032 25,000 11.4 2116 0.026 30,000 10.8 2020 0.019 35,000 10.2 1919 0.013 40,000 9.5 1829 0.009 NOTE: Same as Table 4I Table 4N MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE PLANT: Quad Cities 2 FUEL TYPE: P8DGB263H (Barrier Fuel)

Average Planar Exposure 11APLHGR PCT 0xidation (mwd /t) (kW/ft) ( F) Fraction 200 10.1 1978 0.017 1,000 10.2 1982 0.017 5,000 11.2 2102 0.025 10,000 12.1 2196 0.033 15,000 12.1 2198 0.033 20,000 11.9 2188 0.032 25,000 11.3 2116 0.026 30,000 10.8 2022 0.019 35,000 10.2 1921 0.018 40,000 9.5 1830 0.009 NOTE: Same as Table 4I _

4-13

NEDO-24146A

~

Table 40 MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE PLANT: Quad Cities 2 FUEL TYPE: P8DGB298 (Barrier Fuel)

Average Planar Exposure MAPLHGR PCT 0xidation (mwd /t) (kW/ft) ( F) Fraction 200 G.9 1962 0.016 1,000 9.9 1959 0.016 5,000 10.4 2000 0.018 10,000 11.7 2148 0.028

-15,000 12.0 2198 0.033 20,000 11.9 2194 0.033 25,000 11.6 2153 0.029 30,000 10.9 2074 0.034 35,000 10.2 1963 0.032 40,000 9.5 1827 0.009

' NOTE: Same as Table 41.

Table 4P MAPLHGR VERSUS AVERAGE PLANAR EXPOSURE PLANT: Quad Cities 1,2 FUEL TYPES: P8DRB265L, P8DGB265L (Barrier Fuel)

Average Planar Exposure MAPLHGR PCT 0xidation (mwd /t) (kW/ft) ( F) Fraction l 200 11.6 2171 0.032 1,000 11.6 2177 0.033 5,000 12.0 2198 0.034 10,000 12.1 2195 0.033 15,000 12.1 2199 0.033 20,000 11.9 2187 0.032 25,000 11.3 2115 0.025 30,000 10.7 2018 0.018 35,000 10.2 1927 0.022 40,000 9.6 1834 0.009 NOTE: Same as Table 41.

4-14 J