Application for Amends to Licenses DPR-77 & DPR-79,allowing Entry Into Mode 3 Before Performance of Response Time & Actuation Signal Testing for turbine-driven Auxiliary Feedwater Pump.Fee Paid
ML20155F642
Person / Time
Site: Sequoyah  Tennessee Valley Authority icon.png
Issue date: 06/13/1988
From: Gridley R
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
Shared Package
ML20155F646 List:
References
TAC-R00362, TAC-R00363, TAC-R362, TAC-R363, NUDOCS 8806170003
Download: ML20155F642 (3)


Text

'

, *e TENNESSEE VALLEY AUTHORITY CHATTANOOGA. TENNESSEE 37401 SN 157B Lookout Place UUN 181988 TVA-SQN-TS-88-10 , 10 CFR 50.90 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Hashington, D.C. 20555 Gentlemen:

In the Matter of ) Docket Nos. 50-327 Tennessee Valley Authority ) 50-328 SEQUOYAH NUCLEAR PLANT (SQN) - TECHNICAL SPECIFICATION CHANGE 88 TURBINE-DRIVEN AUXILIARY FEE 0 HATER PUMP (TDAFHP) RESPONSE TIME AND ACTUATION SIGNAL TESTING In accordance with 10 CFR 50.90, we are enclosing a requested amendment to licenses OPR-77 and OPR-79 to change the technical specifications of SQN units 1 and 2. The proposed change will allow entry into mode 3 before performance of the response time and actuation signal testing for the TOAFHP. TVA believes that this change should be approved before restart of SQN unit 1 to avoid any possible misinterpretation of the testing requirements for the TDAFHP.

The proposed technical specification change is identified in enclosure 1. The justification for the proposed technical specification change is provided in enclosure 2. A proposed determination of no significant hazards consideration performed pursuant to 10 CFR 50.92 is provided in enclosure 3.

Enclosed is a check for the $150 amendment application fee required by 10 CFR 170.12.

II g/8 wld&

qf43 A6 8806170003 880613 PDR ADOCK 05000327 P DCD s An Equal opportunity Employer

~*~

UUN 181988 U.S. Nuclear Regulatory Commission Please direct questions you may have concerning this issue to Russell R. Thompson at (615) 870-7470.

Very truly yours, TENN SSEE LEY AUTHORITY R. ridley, 01 ector Nuclear Licen ing and Regulatory Affairs Sworn t___gdsubscribedbeforeme day of Gym /, 1988 this b -

Notary Public My Commission Expires M Enclosures cc: See page 2 cc (Enclosures):

Mr. K. P. Barr, Acting Assistant Director for Inspection Programs TVA Projects'Olvision U.S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 Mr. Michael H. Mobley, Director (w/o enclosures)

Division of Radiological Health T.E.R.R.A. Building

.150 9th Avenue, N Nashville, Tennessee 37203 Mr. G. G. Zech, Assistant Director for Projects TVA Projects Divis' ,

U.S. Nuclear Regulatory Commission One White Flint, North 11555 Rockville Pike Rockville, Maryland 20852 Sequoyah Resident Inspector Sequoyah Nuclear Plant {

2600 Igou Ferry Road Soddy Daisy, Tennessee 37379

ENCLOSURE l PROPOSED TECHNICAL SPECIFICATION CHANGE SEQUOYAH NUCLEAR PLANT UNITS 1 AND 2 DOCKET NOS. 50-327 AND 50-328 (TVA-SQN-TS-88-10)

I LIST OF AFFECTED PAGES Unit 1 3/4 3-29 3/4 3-30 3/4 3-31 3/4 3-32 3/4 3-33a 3/4 7-6

\ Unit 2 3/4 3-29 3/4 3-30 3/4 3-31 3/4 3-32 3/4 3-33a 3/4 7-6

)

l l

\

l l

t j