Proposed Tech Spec Table 3.6.1, Containment Barriers, Deleting Valve VD-V-752 & Tech Spec 3.4.5.1, Main Coolant Leakage Detection Sys, Adding Operability,Action & Surveillance Requirements for Telltale Level Switch
ML20196K736
Person / Time
Site: Yankee Rowe
Issue date: 06/27/1988
From:
YANKEE ATOMIC ELECTRIC CO.
To:
Shared Package
ML20196K730 List:
References
NUDOCS 8807070095
Download: ML20196K736 (3)


Text

. . . .-. -.

, t'_. -

TABLE 3.6-1 (continued) ,

CONTAINMENT BARRIERS TESTABLE DURING ISOLATION FLANT OPERATION TIME VALVE NUMBER FUNCTION (Yes or No) (Seconds)

VD-V-754(4) Neutron Shield Tank Test' NA NA HC-V-602 Air Purge Bypass NA NA CA-V-755(6) -VCPH Pressure Relief NA NA PU-V-051 Containment Sump to Charging NA NA VD-V-917 LPST S.V. Discharge Header NA NA B.2 MANUAL VALVES (Not Subject to Type C Testing)

C. CHECK VALVES (Not Subject to Type C Testing)

SI-V-14 Safety Injection (HP) NA NA CS-V-621 Safety Injection (LP) NA NA CH-V-611 MC Feed to Loop #4 NA NA D.1 REMOTE MANUAL VALVES (Subject to Type C Testing)

CC-TV-205(5) Component Cooling Return No NA CC-TV-208(5) Component Cooling Inlet No NA HV-S0V-39 Hydrogen Monitoring Yes NA HV-SOV-42 Hydrogen Monitoring Yes NA D.2 REMOTE MANUAL VALVES (Not Subject to Type C Testing)

SC -MOV-551/ Shutdown Cooling In No NA 533 (1,2)

SC-MOV-552/ Shutdown Cooling Out No NA 554 (1,2)

CH-MOV-522(7) MC Feed-to-Loop Fill Header No NA

( SI-MOV-516 ECCS Recirculation No NA SI-MOV-517 ECCS Recirculation No NA l

l t

i l

YANKEE R0WE 3/4 6-12 Amendment hv. .,)hf. )hf 8807070095 880627 PDR ADOCK 05000029 P PNU i

i

  • MAIN COOLANT SYSTEM 3/4.4.5 MAIN COOLANT SYSTEM LEAKAGE LEAKAGE DETECTION SYSTEMS LIMITING CONDITION FOR OPERATION 3.4.5.1. The following Main Coolant System leakage detection systems.shall be OPERABLE:
a. At least one containment atmosphere particulate monitoring system.
b. The containment drain tank level monitoring system.
c. The incore detection system thimble leak alarm system.
d. The neutron shield tank telltale leakage detection system.

APPLICABILITY: MODES 1, 2, 3, and 4.

ACTION

a. With the containment atmosphere particulate monitoring system inoperable, operation may continue for up to 7 days provided:
1. Main Coolant System water inventory balance is performed at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
2. The other above required leakage detection systems are OPERABLE, and
3. Appropriate grab samples are obtained and analyzed at least once per hour:

otherwise, be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN .t hin the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

b. With ' e c ntainment drain tank level monitoring system inoperable, rest e t'.e inoperable system to OPERABLE status within 7 days or be in at les H0'. STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the fo' owing 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.
c. ' .th the incore detection system thimble leak alarm system inoperable, restore the leak alarm system to OPERABLE status within 7 days or close all thimble isolation valves; ret are the leak alarm system to OPERABLE status within 31 days or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.
d. With the neutron shicid tank telltale leakage detection system inoperable, restore the inoperable system to OPERABLE status within 7 days or open VD-V-1109 to restore to-OPERABLE status as part of the containment drain tank level monitoring system.

YANKEE R0WE 3/4 4-8

'....'a

  • MAIN COOLA?JT SYSTEM SURVEILLANCE REOUIREMENTS 4.4.5.1 The leakage detection systems shall be demonstrated OPERABLE by:
a. Containment atmosphere particulate monitoring system-performance of CHANNEL CHECK, CHANNEL CALIBRATION and CHANNEL FUNCTIONAL TEST at the frequencies specified in Table 4.3-3,
b. Containment drain tank level monitoring system-performance of CHANNEL FUNCTIONAL TEST at least once per 31 days and CHANNEL CALIBRATION at least once per 18 months.
c. Incore detection system thimble leak alarm system-performance of CHANNEL FUNCTIONAL TEST at least once per 31 days.
d. Neutron shield tank telitale leakage detection system-performance of level switch CHANNEL FUNCTIONAL TEST at least once per 18 months.

\

l l

l YANKEE ROWE 3/4 4-9 i