3/4.6 CONTAINMENT SYSTEM _S_
3/4.6.1 PRIMARY CONTAINMENT CONTAINMENT INTEGRITY LIMITING CONDITION FOR OPERATION 3.6.1.1 Primary CONTAINMENT INTEGRITY shall be maintained.
APPLICABILITY: MODES 1, 2,
3 and 4 ACTION:
Without primary CONTAINMENT INTEGP.ITY, restore CONTAINMENT INTEGRITY within one hour or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.
SURVEILLANCE REQUIREMENTS 4.6.1.1 Primary CONTAINMENT INTEGRITY shall be demonstrated:
a.
At least once per 31 days by verifying that:
1.
All penetrations not capable of being closed by OPERABLE containment automatic isolation valves and required to be closed during accident conditions are closed be vslves, blind flanges, or deactivated automatic valves secured in their positions, except as provided in Table 3.6-1 of Specification 3.6.2 and 2.
All equipment hatches are closed ar.d sealed, b.
By calculating and plotting the containment ui mass as determined by the containment continuous Icek monitoring system at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
c.
By verifying at least once per 3 months that all penetration test, vent and drain connections and instrumentation ports providing a direct path to the containment are isolated with a minimum of one cap, plug, closed valve, instrument or appropriate seal, except as provided in Table 3.6-1 of Specification 3.6.2.
I d.
Any threaded pipe cap or threaded plug used to provide CONTAINMENT INTEGRITY will be torque tested on installation.
,46(AdI YANKEE ROWE 3/4 6-1 Amendment No.
8803300169 880325 ADOCK0500gg9 PDR P
TABLE 3.6-1 CONTAINMENT BARRIERS TESTABLE DURING ISOLATION PLANT OPER.ATION TIME VALVE NUMBER FUNCTION (Yes or No)
(Seconos)
AUTow.ATIC ISOLATION VALVE 5 (Subject to Type C Testing)
A.1 Yes 30 V0-TV-202 Main Coolant Orain Yet 30 V0-T V-203 Main Coolant Vent Yes 30 VD TV-204 Valve Stem Leakoff Yes 30 SA-TV-206 Pain Coolant Sample SA-TV-207 Neutron Shield Tank Sae.ple Yes 30 Yes 30 VO-TV-209
- Containment Orain SW-T V-408 Containe.ent Cooling Water Return Yes 30 SW TV-412 Containment Cooling Vater Inlet Yes 30 Yes 30 HC-TV-409 (14) Containment lleating Condensate Return Yes 30 HC-TV-413 (14) Containment Heating Steam Supply No 30 PR-TV-214 Safety Discharge Header CH LCV-222 Main Coolant Bleed Yes 30 AUTOWATIC ISOLATION VALVES (Net Subject to Type C Testing)
A.2 B.1 KANUAL VALVES (Subject to Type C Testing)
C5-y-601 Shield Tank Cavity Fill NA NA CA-V-746(3)
Containment Air Charge NA NA HV-V-5 Containe.ent H Y'"* I#5*'"
KA kA 2
HV-V-6(8)
Containeent H Vent System RA NA 2
HV-V-34(8)
Containeent H Vent System RA NA 2
CA-V-688 Containment Service Air Supply MA NA j
CA-V-834 Containeent H Vent System Air supply RA NA 2
VD-V-1107(10) g,ng,q3,,ng 3,,p),
gg gg VD-V-110B(10) Containeent Sample NA NA CA V 1275(I)
H Recoe.biner Inlet Tap NA NA 2
CA-Y 1276(8)
H Recombiner Inlet Tap NA KA 2
53)
Containment Air Charge KA RA CA-V-1277 BA-V-61 Containnent Breathing Air M
NA BA-V-63 Containtnent Breathing Air NA NA A,end,ent No.p,56, H,,#
YANKEE ROVE 3/4 6-11 I
}..-
l
_ TABLE 3.6-1 (continued)
CONTAINSENT BARRIERS TESTABLE DURING ISOLATION PLANT OPERATION TIME VALVE NUW.BER FUNCTION (Yes or ho)
(Seconcs) l VD-V-752(4)
Neutron Shield Tank-Outer Test NA NA VD-V-754(4}
Neutron Shield Tank-Inner Test NA NA l
l HC-V-602 Air Purge Bypass RA NA C A-V-755( 6)
VCPH Pressure Relief NA NA PU-V-651 Containment Sump to Charging NA NA VD-V-917 LPST 5.V. Discharge Header NA NA B.2 PANUAL VA'VES (Net Subject to Type C Testing)
C.
CHECK VALVES (Not Subject to Type C Testing)
SI-V-34 (13) Safety Injection (HP)
NA NA C5-V-621 (13) Safety Injection (LP)
NA NA CH-V-611 M* Feed to Loop #4 NA NA D.1 REMOTE FANUAL VALVES (Subjec.t to Type C Testing)
CC-TV-205(5)
Co penent Ccoling Return No NA CC-TV-20B(5)
Component Cooling Inlet No NA HV-50V-39 Hydrogen Monitering Yes NA HV-50V-42 Hydrogen Monitoring Yes NA D.2 REMOTE PANUAL VALVES (Net Subject to Type C Testing)
SC-MOV-551/
Shutdown Cooling In No NA 553 (1,2)
SC-MOV-552/
Shutdown Cooling Out No NA 554 (1,2)
CH-MOV-522(7) MC Feed-to-Loop Fill Header No NA 51-MOV-516 ECCS Recirculation No NA SI-MOV-517
'ECCS Recirculation No NA YANKEE ROVE 3/4 6-12 Amendment No. 69, k.[
l l
TABLE 3.6-1 (continued)
CONTAINMENT BARRIERS TESTABLE DURING ISOLATION VALVE FUMBER FUNCTIOU PLANT OPERATION TIME (Yes or Wo)
(Seconds)
E.1 BAPRIERS (Subject to Type B Testing)
NA NA Demineralized Water Supply (Blank Flange)
NA NA Cavity Purification (Blank Flange)
NA NA L.P. Vent Header (Blank Flange)
NA NA Personnel Airlock WA NA Electrical Penetrations NA NA Fuel Chute (Blank Flange)(9)
NA NA Air Purge Inlet (Blank Flange)
NA NA Air Purge Outlet (Blank Flange)
NA NA l
LPST Safety Valve Discharge Header 5 Blank Flanges (9)
Fuel Chute Dewctering Pump Discharge (Blank Flange)
NA NA E.2 BARRIERS (Not Subject to Type B Testing)
NA NA 18" Bolted Manway NA NA Containment Leg Expansion Joints Fuel Chute Eyjansion Joints (9)
NA NA NA NA Equipment Hatch NA NA Containment Top Manhole Cover NA NA Containment Bottom Manhole Cover NA NA Pressurizer Heise Gauge Line Containment Pressure Sensing Lines (two)
NA NA F.
SAFETY VALVES (Subject to Type C Testing)37-215 LPST Safety Valve (9)
NA NA FA.223 Valve Stem Leakoff Safety Valve NA NA Si-227 CCST Safety Valve NA NA 9
TABLE 3.6-1 (Continued)
TABLE NOTATION (1)
T.S.
4.6.1.1.a.1 not applicable while in Modes 1 or 2, due to ALARA considerations.
(2)
Valves may oe open under administrative control while in Mode 4.
(3)
Valves may be open under administrative control while in Modes 1, 2,
3, or 4 for containment air charge.
(41 Valves may be open under administrative control while in Modes 1, 2,
3, or 4 for neutron shield tank leakage test.
(5)
Normally open and closed by administrative controls.
(6)
CA-V-755 may be unlocked when personnel are in the Vapor container.
Valve may be open while in Modes 1, 2,
3, or 4 for depressurization of the V.C.
personnel hatch during containment access or for testing.
(7)
CH-MOV-522 may be energized under administrative controls.
(8)
Valves may be open under administrative control while in Modes 1, 2,
3, or 4 for surveillance testing.
(9)
T.S.
4.6.1.1.a.1 and 4.6.1.1.c not applicable while in Modes 1, 2,
3, or 4, due to ALARA considerations.
(10) Containment sample valves (VD-V-1107 and VD-V-1108) and their test taps (VD-V-902 and VD-V-909) may be open under administrative control in order to sample containment air.
(11) The ACTION statements of T.S.
3.6.2, 3.0.3 and 3.0.4 do not apply.
(12) Secondary isolation valves may be open under adminsitrative controls.
j (13) Test taps SI-V-94 and SI-V-98 may be open under administra-tive control to relieve safety injection discharge header pressure following surveillance testing.
(14) Strainer Blowdown Valves may be open under administrative control during system startup or for strainer cleanout.
YANKEE-ROWE 3/4 6-15 Amendment No. ps'