LER#78-023/01T-0:on 780925,during Surveillance Test,Control Rod Driveline Breaker a Failed to Trip on First Attempt. Caused by Trip Mechanism Mechanical Arm Being Out of Adjustment.Arm Adjustment Corrected
ML20204B417
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 10/06/1978
From: Shively C
ARKANSAS POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML20204B415 List:
References
LER-78-023-01T, LER-78-23-1T, NUDOCS 7810170146
Download: ML20204B417 (4)