ML20084L881

From kanterella
Revision as of 15:19, 17 April 2020 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Ro:On 740523,activity Level in above-ground Storage Tank in Excess of 0.7 Ci Was Not Recycled to below-ground Storage Tank within 24 H
ML20084L881
Person / Time
Site: Dresden Constellation icon.png
Issue date: 05/27/1974
From: Stephenson B
COMMONWEALTH EDISON CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML20084L877 List:
References
NUDOCS 8305240148
Download: ML20084L881 (1)


Text

.-

n ' -

fus eo=4 O; 4 808 E 9 05/29/74 M mestem union

!$ e O ICS IeMBNGz CSP 3122422734 MGM TDBN MORRIS IL 100 05-29 0615P EDT ZIP 60137 HEE i =.....i

  • a I

O ei O e, I

g> JAMES G KEPPLER REGIONAL DIRECTOR $,

DIRECTORATE OF REGULATORY OPERATIONS REGION 3 US ATOMIC ENERGY COMMISSION 799 ROOSEVELT RD Q GLEN EI. LYN IL 6013 7 $'

O e.

SUBJECT DPR-19 DRESDEN NUCLEAR POWER STATION UNIT TWO THIS WILL CONFIRM A CONVERSATION WITH MR W FISHER OF YOUR OFFICE AT 1610 O HOURS THIS DATE CONCERNING ACTIVITY LEVELS IN AN ABOVE GROUND g STORAGE TANK IN EXCESS OF 0.7 CURIES AS REQUIRED BY SECTION 3.8.D OF THE TECHNICAL SPECIFICATIONS THE TANK WERE NOT REPROCESSED O TO A BELOW GROUND STORAGE TANK WITHIN 24 HOURS THE A WASTE SAMPLE g TA NK CONTAINED 1.04 CURIES WHEN FILLED AT 1504 HOURS ON 5-27-74 DUE TO I NABILITY TO REPROCESS THIS WATER DUE TO IMPROPER FILTER O PERFORMANCE IT WAS THEN TRANSFERED TO ANOTHER ABOVE GROUND TANK g IE THE WASTE SURGE TANK WHICH ADDITIONALLY EXCEEDED LIMITS (l .04 CURI ES) EFFORTS ARE PRESENTLY IN PROGRESS .T0 IMPROVE FILTERING Q PROFORMANCE FURTHER INFORMATION WILL FOLLOW IN A TEN DAY REPORT g B B STEPHENSON SUPERINTENDENT DRESDEN NUCLEAR POWER STATION COMMONWEALTH EDISON CO RURAL ROUTE I MORRIS ILLINOIS 60450 2102 EDT

! O MGMCGBB CGO g O e l

lO e

!O t

e i

iO e o 'j g e J i

MAY f O 3 o yg,, .

tf 0305240148 740606 $

PDR ADOCK 05000237 S PDR

O MGMCGan CG0 0 2-014716E147 05/27/7 p ICS IPM3 NGZ CSP mM "

l  ! $.A#P E 5 "+i IV 3120.422734 MGM TD9N MORRIS IL I N h-$7 NP $

hO j ZIP 60137 O e O e C >aAMES G xEePLERREGIONAL DIRECTOR 8 DIRECTORATE OF REGULATORY OPERATIONS REGION 3 US ATOMIC ENERGY COMMISSION 799 ROOSEVELT RD g O GLENN ELLEN IL 60137 O e

~

O e SU3 JECT DPR19 DRESDEN NUCLEAR POWER ST ATION UNIT 2 THIS WILL CONFIRM A CONVERSATION WITH MR OGG OF YOUR OFFICE AT 1620 HOURS O THIS DATE CONCERNING ACTIVITY LEVEL IN AN A30VE GROUND STORAGE O TANK IN EXCESS OF 0.7 CURIES AS REQUIRED 3Y SECTION 3.8.D OF THE TECHNICAL SPECIFICATIONS THE TANK WAS NOT RECYCLED TO A O 3ELOW GROUND PROCESSING TANx WITHIN THE REauIRED TIME PERIOD e OF P.4 HOURS THE WASTE SURGE TANK C0!!TAINED 1.08 CURIES WHEN FILLD TO A 65 DERCENT LEVEL AT 2140 HOURS ON 5-23-74 SUBSEQUENT O PR') CESSING DID NOT 3 RING THE ACTIVITY WITHIN SPECIFICATIONS O UNTIL 0445 HOURS ON 5-27-74 FURTHER INFORMATION WILL FOLLOW THIS NOTIFICATION IN A TEN DAY REPORT O 3 3 STEPHENSON SUPERINTENDENT DRESDEN NUCLEAR POWER STATION O COMM0 WEALTH EDISON C0 RR 1 MORRIS IL 60450 O i73, EDT g g #

O "'"C"'^ j' fhm go a

y w O -

p va 7 .:

e I 1 0 ;z tu

<.M a" e O e O el po O a.J ,

e NAY : P 'y ' \ t* lh O

<[s e O e, 1

0 ea