ML13178A365
ML13178A365 | |
Person / Time | |
---|---|
Site: | Perry |
Issue date: | 03/14/2013 |
From: | NRC/RGN-III |
To: | FirstEnergy Nuclear Operating Co |
Bielby, M. | |
Shared Package | |
ML11354A269 | List: |
References | |
Download: ML13178A365 (1) | |
Text
ES-401, Rev. 9 Record of Rejected K/As Form ES-401-4 Tier / Group Randomly Reason for Rejection Selected K/A 1/1/RO 295028 EA1.01 Perry does not have Drywell Spray. Randomly selected EA1.02 Drywell ventilation.
2/1 RO 223002 K2 K2 does not contain any Importance Rating 2.5; randomly selected K3 2/1 RO 300000 K6.04 Perry does not have Service air refusal valves. Randomly selected K6.07 Valves 2/2/RO 290003 K2 K2 does not contain any Importance Rating 2.5. Randomly selected K1 2/2/RO 290002 K2 K2 does not contain any K/A. Randomly selected A4. A4 does not contain any K/A.
Randomly selected A2 3 SRO 2.4.20 Was unable to write a discriminating question for selected K/A. Randomly selected K/A 2.4.32 2/1/SRO 2.4.20 Was unable to write a discriminating question for selected K/A. Randomly selected K/A 2.2.37 2/1/SRO 2.2.44 Was unable to write a discriminating question for selected K/A. Randomly selected K/A 2.1.32 2/1/RO 209001 2.4.8 Selected K/A (generic part) was covered on Audit Exam. Randomly selected K/A K2.01.
2/1/RO 211000 K2.02 Was unable to write an operationally valid discriminating question for selected K/A.
Randomly selected K/A K2.01 2/1/RO 215005 K6.05 Selected K/A was on failure of the IRMs on APRMs. Could not write an operationally valid question. Randomly selected K/A 215005 K6.03 (Detectors)
Page 1 of 1 Rev 1