ML17266A139

From kanterella
Revision as of 02:52, 19 June 2019 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Jump to navigation Jump to search
LER 79-036/03L-0:on 791203,while Operating at Full Power, Control Room Operator Discovered Mb Linear Power Range Channel High Voltage Was Lower than Other Three Channels. Caused by Failed +15 Volt Power Supply.Supply Replaced
ML17266A139
Person / Time
Site: Saint Lucie NextEra Energy icon.png
Issue date: 01/02/1980
From: Schoppman M
FLORIDA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML17207A787 List:
References
LER-79-036-03L-01, LER-79-36-3L-1, NUDOCS 8002040535
Download: ML17266A139 (2)


Text

NRC FORM MS f7.77 I LICENSEE EVENl'f QOR7 U.*NUCLEAR REGULATORY COMMISSION

~O 1 3 CON T~o t 3'O IPLKASc PRIIIT OR TYP ALI.RKCUIRKD INFORMATIONI I IQ I I-I I I I I-I I Q I I I I IQ~IQ 9 IJCKNSKE COOK I"$\IC Nsc p'IIFMSER~S$I iCSNSE YPS 13 St CAT Q":::i Ii.O I Q~O~O$0 Sl OOC)CPT NUAISER sa os ivaNT Q*TE I+TS R'EPQRT O*FTS 30 EVENT OKSCRIPTION

'NO I'ROSAKLK CONScCUENCKS QIO'4'hile o eratin at 100%ower 1 o erator discovered that~03 the"MB" linear over ran'channel hi Qh vol tR I w.41=50V lover than the~o~othe channels.The"MB" lin r~~~4-n was declared ino er-able and the"Hi Pover>>IITM Lptt'ILoss of Lo dtt It PPCF trips vere placed in b ass in accordance with Technical S e f'.3.1.1.The 15V power su 1 was re37laced and the"hlB" channel re r within the time limit s ecified.Thre~7 3 9 o erable.~og over su 1 Techni Power Model I,"PL 14.5-3.0.Ho cause could be deter-SYSTEM CAUSE CAUSE COMP VALVS CQOE CQOK SUSCQQE CCMPONK4T COOK sua"Qca suacocs S LCS LLS~l,!, Q mc LQ 1 S 9 IO l2 12 IS 2O 54OUENTIAL OCCURAK4CK REPORT REVI$IO4~LSRIRQ 4VKNTYKAR REPORT NO, COCK TYPE"IO.Qo FiPFFF 12 22 24 1S Tt~$M O)22 ACTION SUTURc EFPPC SIRUTQCPRIN A~.ACIFMENT NPROM PRIME C Ms, CQM PC N ck T TPUCEN lcTIQIt ck PLANT NKTNQQ NQUAS+22'USMIT~'SO FP PIMSUS.SUPPLIER FPIANUFACTURAR LJSLQS LJS.IRIS~i Lic LRS I IS CAUSE DESCRIPTION ANO CORRECF IVK ACTIONS Q27 The"HB" linear over ran e hi h voltage failed low due to a failed+15V mined for this failure.Immediate corrective action was to reolace the over su 1.No further corrective action is reouired.i 9 FACILI Y Si*TUS OTIIER STATUS 0 NA Qci LJS~i~a IO.I2 IS ac ACTIVITY CQNT44T RELKASEQ QP RELEASE AMOUNT OP ACTIFPITY QSS~Z Q~~QK.NA I 3 9 IO 44 PERSONNEL fXPOSUIIES 4UAISER TYPE QESCRIPTION QN~ii LoOooo'iQ>>Lz le 1 9 3 Il I2.Is PcilsONNEL IktURFES[ii~J~oo o IQF METRO"4 OISCQVECY~A.'~31.4$NA NA'ISCCVERY QES WPTICAI S2 Operator Observation LOCATION OS AELKASc Q38 SO 30 g 2 a 2 9 I I I'1 LCSS QII CR 0AM ACE.0 F ACI LITY Qas TYPE OESCRIPTIQN

~Z'A2 IO PUSLlc:..ISSUEQ OESCRIPT:QN 9 IQaa 2 IO MAFIA RP>RRPAR;R~NA NA 80080iso 30 NRC USE ONI.Y I'l'III I I SS i$4 PI.ON s.('7

,<<4