Oconee Unit 2, EOC 21 Refueling Outage Inservice Inspection Report, Fourth Ten-Year Inservice Inspection Interval
ML060580472
Person / Time
Site: Oconee Duke Energy icon.png
Issue date: 02/23/2006
From: Hamilton B H
Duke Power Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML060580472 (366)


Text

{{#Wiki_filter:BRUCE H HAMILTON wMQue Vice President c SWPowere Oconee A'uclear Station Duke Power ONO0VP / 7800 Rocherster Highway Seneca, SC 29672 864 885 3487 864 885 4208 fax February 23, 2006 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555

Subject:

Duke Energy Company Oconee Nuclear Station, Unit 2 Docket No. 50-270 Unit 2 EOC 21 Refueling Outage Inservice Inspection Report Fourth Ten-Year Inservice Inspection Interval Please find attached a copy of the Inservice Inspection Report for Oconee Unit 2 End of Cycle 21 Refueling Outage. This report is submitted pursuant to Section XI of the ASME Boiler arid Pressure Vessel Code, 1998 Edition, with 2000 addenda, Article IWA 6230.If there are any questions you may contact R. P. Todd at (864)885-3418.B. H. Hamilton, Site Vice-President Oconee Nuclear Station Attachment ACS '-7 www. dukepower. corn U. S. Nuclear Regulatory Commission February 23, 2005 Page 2 xc wo/attachment: Mr. William D. Travers Administrator, Region II U.S. Nuclear Regulatory Commission 61 Forsyth Street, S. W., Suite 23TE.5 Atlanta, GA 30303 Leonard N Olshan, Projects Manager Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Mr. M. C. Shannon NRC Senior Resident Inspector Oconee Nuclear Station-L INSEER VICE INSPECTION REPORT DUKE POWER COMPANY OCONEE NUCLEAR STATION UNIT 2 TWENTY-FIRST REFUELING OUTAGE D Duke Uo Power.M A Duke Energy Company 1i, 1 Owner's Report For INSERVICE. INSPECTIONS OCONEE UNIT 2 2005 REFUELING OUTAGE EOC21 (OUTAGE 1)Plant Location: 7800 Rochester Highway, Seneca, South Carolina 29672 NRC Docket No. 50-270 Commercial Service! Date: September 9, 1974 Document Completion Date a 06 Owner: Duke Energy Corporation 526 south Church St.Charlotte, N. C. 28201-1006 Revision 0 Prepared By: I Co Date /- I q-(o 6 Reviewed By: Date I _ I _ a 6 Date / sL Approved By: FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules 1. Owner: Duke Energy Corporation, 526 S. Church St.. Charlotte. NC 28201-1006 (Name and Address of Owner)2. Plant: Oconee Nuclear Station, 7800 Rochester Highwav, Seneca. SC 29672 (Name and Address of Plant)3. Plant Unit: 2 4. Owner Certificate of Authorization (if required) N/A 5. Commercial Service Date: September 1< 1974 6. National Board Number for Unit N/A 7. Components Inspected: Component or Appurtenance Manufacturer Installer Manufacturer Installer Serial No.State or Province No.National Board No.See Section 1.1 in the Attached Report Note: Supplemental sheets in the form of lists, sketches, or drawings may be used provided (1) size is 81/2 in. x 11 in., (2) information in items 1 through 6 on this data report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.Total number of pages contained in this report 363 . FORM NIS-1 (Back)8. Examination Dates June 15, 2004 to November 30, 2005 9. Inspection Period Identification: First Period 10. Inspection Interval Identification:

11. Applicable Edition of Section XI 12. Date/Revision of Inspection Plan: Fourth Interval 1998 Addenda 2000 -June 23, 2004 / Revision 0 13. Abstract of Examinations and Tests. Include a list of examinations and tests and a. statement concerning status of work required for the Inspection Plan. See Sections 2.0. 3.0 and 6.0 14. Abstract of Results of Examination and Tests.15. Abstract of Corrective Measures.See Sections 4.0 and 6.0 See Subsection 4.3 We certify that a) the statements made in this report are correct b) the examinations and tests meet the Inspection Plan as required by the ASME Code, Section XI, and c) corrective measures taken conform to the rules of the ASME Code, Section XI.Certificate of Authorization No. (if applicable)

NA Expiration Date NA Date I/3 /04/ I}Signed Duke Energy Corp. By G Owner CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of .4,arA' w cl.oz-Ajy employed by *The HSBI&I Co. of Connecticut have inspected the components described in this Owner's Report during the period__ -_ _-_o_ le_ to s.-s'- CaTm -, and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in the Owner's Report in accordance with the Inspection Plan and as required by the ASMIE Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, test, and corrective measures described in this Owner's Report.Furthermore, neither the Inspector nor his employer shall be liable in any manner for amy personal injury or property damage or a loss of any kind arising from or connected with this inspection Commissions C/'/A),A9de Ins-p-tor's Signature National Board, State, Province, and Endorsements Date Z -S-C? 6* The Hartford Steam Boiler Inspection & Insurance Company of Connecticut. 200 Ashford Center North Suite 205 Atlanta, GA. 30338-4860 (800) 417-3721 www.hsbc.com DISTRIBUTION LIST 1. Duke Energy Corporation Nuclear Quality Assurance and Oversight Division Quality Assurance Technical Services 2. NRC Document Control Desk 3. Hartford Steam Boiler Inspection and Insurance Company of Connecticut (AIA)c/o ANII at Oconee Note: The following personnel are to be notified via e-mail after the Inservice Inspection Report has been stored in the Nuclear Electronic Document Library: GO Nuclear Assurance c/o Bruce Nardoci Inspection and Welding Services (ISI Coordinator) TABLE OF CONTENTS Section Tiltle Revision 1.0 General Information 0 2.0 Fourth Ten Year Inspection Status 0 3.0 Final Inservice Inspection Plan 0 4.0 Results of Inspections Performed 0 5.0 Owners Report for Repair/Replacement Activities 0 6.0 Pressure Testing 0

1.0 General

Information This report describes the Inservice Inspection of Duke Energy Corporation's Oconee Nuclear Station, Unit 2, during Outage 1/EOC 21. This is thei first outage in the first inspection period of the Fourth Ten-Year Interval. ASME Section Xl, 1998 Edition with the 2000 Addenda, was the governing Code for selection and performing of the ISI examinations. Included in this report are: the inspection status for each examination category, the final inservice inspection plan, the inspection results for each item examined, and corrective actions taken when reportable conditions were found. In addition, there is an Owner's Report for Repair/Replacement Section included for completed NIS-2 documentation of repairs and replacements.

1.1 Identification

Numbers Manufacturer Item Manufacturer or Installer State or National or Installer _ Serial No. Province No. Board No.Reactor Vessel Babcock & Wilcox 620-0004-51-52 N/A N-1 05 Reactor Vessel Babcock & Wilcox 068S-02 N/A 209 Head (replaced head)Steam Generator A Babcock & Wilcox 006K03 N/A 207 Steam Generator B Babcock & Wilcox 006K04 N/A 208 Pressurizer Babcock & Wilcox 620-0004-59 N/A N-1 06 Main Steam Duke Power NA NA NA System Auxiliary Steam Duke Power NA NA NA System _Feedwater System Duke Power NA NA NA Emergency Duke Power NA NA NA Feedwater System _Steam Generator Duke Power NA NA NA Flush System _Condensate Duke Power NA NA NA System _EOC 21 Refueling Outage Report Oconee Unit 2 Section 1 Page 1 of 4 Revision 0 January 16, 2006 Manufacturer Item Manufacturer or Installer State or National or Installer Serial No. Province No. Board No.Vents and Exhaust Duke Power NA NA NA System _Condenser Duke Power NA NA NA Circulating Water High Pressure Duke Power NA NA NA Service Water System Low Pressure Duke Power NA NA NA Service Water System _Reactor Coolant Duke Power NA NA NA System _High Pressure Duke Power NA NA NA Injection System _Low Pressure Duke Power NA NA NA Injection System _Reactor Building Duke Power NA NA NA Spray System _Component Duke Power NA NA NA Cooling System _Spent Fuel Cooling Duke Power NA NA NA System _Vents -Reactor Duke Power NA NA NA Building Components _Drains -Reactor Duke Power NA NA NA Building Components _EOC 21 Refueling Outage Report Oconee Unit 2 Section 1 Page 2 of 4 Revision 0 January 16, 2006 1.2 Personnel. Equipment and Material Certifications All personnel who performed or evaluated the results of inservice inspections during the time frame bracketed by the examination dates shown on the NIS-1 Form were certified in accordance with the requirements of 1998 Edition of ASME Section Xi with the 2000 addenda including Appendix VII for ultrasonic inspections. In addition, ultrasonic: examiners were qualified in accordance with ASME Section Xl, Appendix VIII, and 1998 Edition with the 2000 Addenda through the Performance Demonstration Initiative (PDI) for similar metal piping welds and reactor vessel shell welds.The appropriate certification records for each inspector, calibration records for inspection equipment, and records of materials used (i.e., NDE consumables) are on file at Oconee Nuclear Station or copies can be obtained by contacting Duke Energy's Corporate Office in Charlotte, North Carolina.The copies of the certification records for Washington Group International inspectors and Atlantic Group inspectors can be obtained by contacting Duke Energy's Corporate Office in Charlotte, North Carolina.1.3 Reference Documents The following reference documents apply to the inservice inspections performed during this report period. A copy may be obtained by contacting the ISI Plan Manager at Duke Energy's Corporate Office in Charlotte, North Carolina.Code Case N-460 (Applicable to items in this report where less than 100%coverage of the required weld examination volume was achieved.) These items are identified on the Run D that is located in Section 4 of this report.Duke Power Company Problem Investigation Process Report # 0-05-06919. This PIP was written to document a problem found with PZR Circumferential Head Weld documentation (Item [302.011.001) from a previous inspection in the third interval.Duke Power Company Problem Investigation Process Report # 0-05-07724. This PIP was written to document a problem found with work orders that were written to perform ISI on Unit 2 items during EOC-21 but the work orders were not scheduled to be completed until after the outage.Duke Power Company Problem Investigation Process Report # 0-05-08427. This PIP was written to track the Relief Request process for limited coverage on UT examinations of welds that were inspected during EOC-21 for Unit 2.Request for Relief 04-ON-01 5 (Allows Duke to exempt the examination for B03.160 items for the 4 th interval.) EOC 21 Refueling Outage Report Page 3 of 4 Oconee Unit 2 Revision 0 Section 1 January 16, 2006 Request for Relief 03-006 (Allows Duke and Alternative for the Snubber Examinations required in IWF-5000 for the 4th interval.)

1.4 Augmented

and Elective Examinations Augmented and elective examination information found within this Inservice Inspection Report is not required by the ASME Section Xl Code; therefore, it is exempt from ANII review, verification, and/or record certification.

1.5 Responsible

Inspection Agency The Hartford Steam Boiler Inspection and Insurance Company of Connecticut is responsible for the third party inspections required by ASME Section Xl.Authorized Nuclear Inservice Inspector(s) Name: Employer: Business Address: Gary Brouette, Nancy Slaughter, Randy Klein, Tom Wyatt and Ed Reyes The Hartford Steam Boiler Inspection & Insurance Company of Connecticut. 200 Ashford Center North Suite 205 Atlanta, GA 30338-4860 (800) 417-3721 www.hsbct.com EOC 21 Refueling Outage Report Oconee Unit 2 Section 1 Page 4 of 4 Revision 0 January 16, 2006

2.0 Fourth

Ten Year Interval Insnection Status The completion status of inspections required by the 1998 ASME Code Section XI, with the 2000 Addenda, is summarized in this section. The requirements are listed by the ASME Section Xl Examination Category as defined in Table IWB-2500-1 for Class 1 Inspections, Table IWC-2500-1 for Class 2 Inspections, and IWF-2500-1 for Class 1 and 2 Component Supports. Augmented inspections are also included.Class l Inspections Examination Inspections Inspections Percentage Deferral Category Description Required Completed Completed Allowed B-A Pressure Retaining Welds 6 Welds 0 Weld 0% Yes in Reactor Vessel _B-B Pressure Retaining Welds 10 Welds 2 Welds 20% No in Vessels Other than Reactor Vessel _B-D Full Penetration Welds of 38 4 11% Partial Nozzles in Vessels Inspections Inspections Inspection Program B ._B-E Pressure Retaining Partial Penetration Welds in REFERENCE SECTION 6.0 OF THIS REPORT Vessels B-F Pressure Retaining 7 Welds 0 Welds 0% No Dissimilar Metal Welds _B-G-1 Pressure Retaining Bolting 128 Items 40.33 Items 32% Yes Greater than 2 Inches in Diameter _B-G-2 Pressure Retaining Bolting 16 Items 5 Items 31% No 2 Inches and Less in Diameter B-J Pressure Retaining Welds 165 Welds 16 Welds 10% No in Piping _B-K Welded Attachments for 21 2 10% No Vessels, Piping, Pumps and Valves _ _* Deferral of inspection to the end of the interval as allowed by ASME Section Xl Tables IWB and IWC 2500-1.EOC 21 Refueling Outage Report Oconee Unit 2 Section 2 Page 1 of 4 Revision 0 January 16, 2006 Class 1 Inspections (Continued) Examination Inspections Inspections Percentage

  • Deferral Category Description Required Completed Completed Allowed B-L-1 Pressure Retaining Welds 1 Weld 0 Weld 0% Yes in Pump Casings B-L-2 Pump Casings 1 Casinq 0 Casing 0% Yes B-M-1 Pressure Retaining 1 Valve Body 0 Valve Body 0% Yes Welds in Valve Bodies Weld Weld B-M-2 Valve Bodies 4 Valves 0 Valves 0% Yes B-N-1 Interior of Reactor Vessel 3 Inspections 1 Inspection 33% No B-N-2 Welded Core Support 1 Inspection 0 Inspections 0% Yes Structures and Interior Attachments to Reactor Vessels _B-N-3 Removable Core Support 1 Inspection 0 Inspections 0% Yes Structures

_ _B-0 Pressure Retaining Welds 1,2 Housing 4 Housing 33% Yes in Control Rod Housings Welds Welds _B-P All Pressure Retaining Components REFERENCE SECTION 6.0 OF THIS REPORT B-Q Steam Generator Tubing N/A N/A l N/A N/A F-A Class 1 Component 37 Supports 7 Supports 19% No F1.10 & F1.040 Supports (Except items. Snubbers) _F-A Class 1 Component

    • F1.050 items Supports, Snubbers _*Deferral of inspection to the end of the interval as allowed by ASME Section Xl Tables IWB and IWC 2500-1.* Inspected under Selected License Commitment 16.9.18 per Relief Request 03-006*EOC 21 Refueling Outage Report Oconee Unit 2 Section 2 Page 2 of 4 Revision 0 January 16, 2006 Class :2 Inspections Examination Inspections Inspections Percentage
  • Deferral Category Description Required Completed Completed Allowed C-A Pressure Retaining Welds 4 Welds 0 Welds 0% No in Pressure Vessels C-B Pressure Retaining Nozzle 4 Welds 2 Welds 50% No Welds in Vessels C-C Integral Attachments for 37 7 19% No Vessels, Piping, Pumps Attachments Attachments and Valves _C-D Pressure Retaining Bolting 2 Items 0 Items 0% No Greater Than 2 Inches in Diameter _ _C-F-1 Pressure Retaining Welds 166 Welds 24 Welds 14% No in Austenitic Stainless Steel or High Alloy Piping _C-F-2 Pressure Retaining Welds 61 Welds 7 Welds 11% No in Carbon or Low Alloy Steel Piping C-G Pressure Retaining Welds N/A N/A N/A N/A in Pumps and Valves _C-H All Pressure Retaining Components REFERENCE SECTION 6.0 OF THIS REPORT F-A Class 2 Component 135 Supports 20 Supports 15% No F1.020 & F1.040 Supports (Except items. Snubbers)

_F-A Class 2 Component

    • F1.050 items Supports, Snubbers*Deferral of inspection to the end of the interval as allowed by ASME Section Xi Tables IWB and IWC 2500-1.** Inspected under Selected License Commitment 16.9.18 per Relief Request 03-006 EOC 21 Refueling Outage Report Oconee Unit 2 Section 2 Page 3 of 4 Revision 0 January 16, 2006 Augmented/E lective Inspections Augmented and elective examination information found within this Inservice' Inspection Report is not required by the ASME Section XI Code; therefore, it is exempt from ANII review, verification, and/or record certification.

itemPecnaeCrplt Number Description Percentage Complete GO1.001 Reactor Coolant Pump Flywheel None scheduled for EOC 21 G02.001 HPI Nozzle Safe End Examinations None scheduled for EOC 21 G03.001 Pressurizer Surge Line Examinations None scheduled for EOC 21 G04.001 Thermal Stress Piping (NRC Bulletin None scheduled for EOC 21 88-08)G1i1.001.001 Reactor Pressure Vessel Head None scheduled for EOC 21 Penetration Nozzle by UT Examination per NRC Order EA-03-009. G1i1.001.002 Bare Metal Visual Examination of the None scheduled for EOC 21 Reactor Pressure Vessel Head Surface per NRC Order EA-03-009. H01.001 Pressurizer Sensing/ Sampling Nozzle None scheduled for EOC 21 Safe Ends H02.001 Class 1 RTE Mounting Bosses None scheduled for EOC 21 H03.001 Main Feedwater Piping in the East and 100% of EOC 21 Requirements West Penetration Rooms per QA-513J_(ER-ONS-04-03) H04.001 -Main Feedwater and Main Steam Piping 100% of EOC 21 Requirements Supports and Attachment Welds per OA-513J (ER-ONS-04-05) EOC 21 Refueling Outage Report Oconee Unit 2 Section 2 Page 4 of 4 Revision 0 January 16, 2006

3.0 Final

Inservice Inspection Plan The final Inservice Inspection Plan shown in this section lists all ASME Section Xl Class 1, Class 2, Class 3, and Augmented examinations credited for this report period.The information shown below is a field description for the reporting format included in this section of the report: Item Number ID Number Sys Iso / Dwg. Numbers Proc Insp Req.Mat / Sch.Diam. / Thick Cal Blocks Comments= ASME Section Xl Tables IWB-2500-1 (Class 1), IWC-2500-1 (Class 2), IWF-2500-1 (Class 1 and Class 2 ), Augmented Requirements -Unique Identification Number= Component System Identification = Location and/or Detail Drawings= Examination Procedures = Examination Technique -Magnelic Particle, Dye Penetrant, etc.= General Description of Material= Diameter/Thickness -Calibration Block Number= General and/or Detail Description EOC 21 Refueling Outage Report Oconee Unit 2 Section 3 Page 1 of 1 Revision 0 January 16, 2006 EOC 21 V CATEGORY B-B. Pressure Retaining Welds In Vessels Other Than Reactor Vessels Pressurizer ITEM NUMBER ID NUMBER SYS ISO/DWG NUI**** Shell-to-Head: Circumferential

        • -DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 3ERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS Plan Report Page 1 01116/2006

\AI COMMENTS B02.01 1.001 2-PZR-WP76 ISI-OCN2-002 NDE-640 UT CS 84.000 40338 Pressurizer Upper Head Pc. 5 to Upper Shell Circumferential 50 OM-1201-456 NDE-820 6.188 Course Pc. 1. Material thickness ranges from 6.50" Class A Head to to 4.750" due to taper of material.Shell Total B02.011 Items: 1**** Shell-to-Head; Longitudinal

        • B02.012.001 2-PZR-WP1-1 Longitudinal Class A ISI-OCN2-002 50 OM-1201-456 NDE-640 NDE-820 UT CS 0.000 40338 6.188 Shell to Shell Pressurizer Upper Shell Course Pc. 1 to Upper Shell Course Pc. 1.Total 80no Ite it2me Total B02 Items: 1 2 EOC 21 %CATEGORY B-D. Full Penetration Welded Nozzels In Vessels -Inspection Program B WHeat Exchangers (Primary Side)ITEM NUMBER ID NUMBER SYS ISO/DWG DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Plan Report Page 2 01/1612006
        • Nozzle-to-Vessel Welds ****B03.150.001 2-LDCA-IN-V1 1-44773-1 See Corn UT SS 3.000 40411 Letdown Cooler 2A Tubeside Inlet Nozzle Pc. 5 to Circumferential 51A OM-201-3107 0.875 Channel Body Pc. 3.Class A O-ISIN4-101A-2.1 Nozzle to Procedure 3630 Channel Body B03.150.002 2-LDCA-OUT-V2 1-44773-1 See Corn UT SS 3.000 40411 Letdown Cooler 2A Tubeside Outlet Nozzle Pc. 5 to Circumferential 51A OM-201-3107 0.875 Channel Body Pc. 3.Class A O-ISIN4-101A-2.1 Nozzle to Procedure 3630 Channel Body Total B03.150 Items: 2 U EOC 21 I CATEGORY B-D. Full Penetratik Nozzels In Vessels -Inspection.leat Exchangers (Primary Side)ITEM NUMBER ID NUMBER DUKE ENERGY CORPORATION on Welded INSERVICE INSPECTION PLAN MANAGEMENT Program B Inservice Inspection Database Management System Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Plan Report Page 3 01/16/2006
        • Nozzle Inside Radius Section ****B03.160.001 2-LDCA-IN-V1 1-44773-1 TBD UT SS 3.000 TBD Letdown Cooler 2A Tubeside Inlet Nozzle Pc. 5to 51A OM-201-3107 0.875 Channel Body Pc. 3. (Inside Radius Section)Class A O-ISIN4-101A-2.1 Nozzle to This item is not to be inspected.

A Relief Request Channel Body will be filed to exempt us from examining this item.B03.160.002 2-LDCA-OUT-V2 1-44773-1 TBD UT SS 3.000 TBD Letdown Cooler 2A Tubeside Outlet Nozzle Pc. 5 tc 51A OM-201-3107 0-ISIN4-101A-2.1 0.875 Class A Total B03.160 Items: Total B03 Items: Nozzle to Channel Body Channel Body Pc. 3. (Inside Radius Section)This item is not to be inspected. A Relief Request will be filed to exempt us from examining this item.2 4 r M 40, q EOC 21 A I DUKE ENERGY CORPORATION CATEGORY B-G-1. Pressure Retainin Bolting, INSERVICE INSPECTION PLAN MANAGEMENT Greater Than 2 in. In Diameter Reactor Vessel ITEM NUMBER ID NUMBER Inservice Inspection Database Management System Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 Plan Report Page 4 01/16/2006 SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS**** Closure Head Nuts ****B06.010.001 2-RPV-26-204-01 OM-1201-4 QAL-13 VT-1 CS 9.250 Reactor Vessel Closure Nut Pc. 26.50 B&W152009E 1.300 Class A B06.010.002 2-RPV-26-204-02 OM-1201-4 QAL-13 VT-1 CS 9.250 Reactor Vessel Closure Nut Pc. 26.50 B&W152009E 1.300 Class A B06.010.003 2-RPV-26-204-03 OM-1201-4 QAL-13 VT-1 CS 9.250 Reactor Vessel Closure Nut Pc. 26.50 B&W 152009E 1.300 Class A B06.010.004 2-RPV-26-204-04 OM-1201-4 QAL-13 VT-1 CS 9.250 Reactor Vessel Closure Nut Pc. 26.50 B&W152009E 1.300 Class A B06.010.005 2-RPV-26-204-05 OM-1201-4 QAL-13 VT-1 CS 9.250 Reactor Vessel Closure Nut Pc. 26.50 B&W 1 52009E 1.300 Class A B06.010.006 2-RPV-26-204-06 OM-1201-4 QAL-13 VT-1 CS 9.250 Reactor Vessel Closure Nut Pc. 26.50 B&W152009E 1.300 Class A B06.010.007 2-RPV-26-204-07 OM-1201-4 QAL-13 VT-1 CS 9.250 Reactor Vessel Closure Nut Pc. 26.50 B&W152009E 1.300 Class A B06.010.008 2-RPV-26-204-08 OM-1201-4 50 B&W152009E QAL-1 3 VT-1 CS 9.250 1.300 Reactor Vessel Closure Nut Pc. 26.Class A I K EOC 21 DUKE ENERGY CORPORATION CATEGORY B-G-1, Pressure Retaining Bolting. INSERVICE INSPECTION PLAN MANAGEMENT Greater Than 2 in. In Diameter Reactor Vessel ITEM NUMBER ID NUMBER B06.010.009 2-RPV-26-204-09 Inservice Inspection Database Management System Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 Plan Report Page 5 01/16/2006 SYS ISO/DWG NUMBERS PROC QAL- 1 3 INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS OM-1 201-4 50 B&W152009E VT-1 CS 9.250 1.300 Reactor Vessel Closure Nut Pc. 26.Class A B06.010.010 2-RPV-26-204-10 OM-1201-4 QAL-13 VT-1 CS 9.250 Reactor Vessel Closure Nut Pc. 26.50 B&W152009E 1.300 Class A B06.010.011 2-RPV-26-204-11 OM-1201-4 QAL-13 VT-1 CS 9.250 Reactor Vessel Closure Nut Pc. 26.50 B&W 1 52009E 1.300 Class A^&A 4nfldfAlAl Afl ifl 1%1foea finatirnflhit Pt B06.0,0.012 2-RP 204-12 OM-1201- I wr% ICSP 0 RureNutPc.26. 50 B&W 152009E 1.300 Class A B06.010.013 2-RPV-26-204-13 OM-1201-4 QAL-13 VT-1 CS 9.250 Reactor Vessel Closure Nut Pc. 26.50 B&W152009E 1.300 Class A B06.010.014 2-RPV-26-204-14 OM-1201-4 QAL-13 VT-1 CS 9.250 Reactor Vessel Closure Nut Pc. 26.50 B&W152009E 1.300 Class A B06.010.015 2-RPV-26-204-15 OM-1 201-4 QAL-1 3 VT-1 CS 9.250 Reactor Vessel Closure Nut Pc. 26.50 B&W152009E 1.300'Class A B06.010.016 2-RPV-26-204-16 OM-1201-4 QAL-13 VT-1 CS 9.250 Reactor Vessel Closure Nut Pc. 26.50 B&W152009E 1.300 Class A B06.010.017 2-RPV-26-204-17 OM-1201-4 50 B&W152009E QAL-13 VT-1 CS 9.250 1.300 Reactor Vessel Closure Nut Pc. 26.Class A f Ur e-96EOC 21 k st DUKE ENERGY CORPORATION CATEGORY B-G-1 Pressure Retainina Bolting INSERVICE INSPECTION PLAN MANAGEMENT Greater Than 2 in. In Diameter Inservice Inspection Database Management System Reactor Vessel Oconee 2* Inservice Inspection Plan for Interval 4 Outag 3el Plan Report Page 6 01/16/2006 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B06.010.018 2-RPV-26-204-18 OM-1201-4 QAL-13 VT-1 CS 9.250 Reactor Vessel Closure Nut Pc. 26.50 B&W152009E 1.300 Class A B06.010.019 2-RPV-26-204-62 OM-1201-4 QAL-13 VT-1 CS 9.250 Reactor Vessel Closure Nut Pc. 26.50 B&W 1 52009E 1.300 Class A B06.010.020 2-RPV-26-204-20 OM-1201-4 QAL-13 VT-1 CS 9.250 Reactor Vessel Closure Nut Pc. 26.50 B&W152009E 1.300 Class A Total B06.010 Items: 20 fr U1 EOC 21 I >DUKE ENERGY CORPORATION CATEGORY B-G-1 Pressure Retaining Bolting, INSERVICE INSPECTION PLAN MANAGEMENT Greater Than 2 in. In Diameter Inservice Inspection Database Management System EReactor Vessel Oconee 2* Inservice Inspection Plan for Interval 4 Outage 1 Plan Report Page 7 01/16/2006 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS**** Closure Studs, when removed ****B06.030.001 2-RPV-25-204-01 OM-1201-4 See Com UT CS 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -Removed.50 B&W 152009E 0.000 Stud Length = 63.250. Procedure

  1. PDI-UT-5.Class A B06.030.002 2-RPV-25-204-02 OM-1201-4 See Corn UT CS 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -Removed.50 B&W152009E 0.000 Stud Length = 63.250. Procedure
  2. PDI-UT-5.Class A B06.030.003 2-RPV-25-204-03 OM-1201-4 See Corn UT CS 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -Removed.50 B&W152009E 0.000 Stud Length = 63.250. Procedure
  3. PDI-UT-5.Class A B06.030.004 2-RPV-25-204-64 OM-1201-4 See Com UT CS 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -Removed.50 B&W152009E 0.000 Stud Length = 63.250. Procedure
  4. PDI-UT-5.Class A B06.030.005 2-RPV-25-204-05 OM-1201-4 See Corn UT CS 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -Removed.50 B&W152009E 0.000 Stud Length = 63.250. Procedure
  5. PDI-UT-5.Class A B06.030.006 2-RPV-25-204-06 OM-1201-4 See Corn UT CS 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -Removed.50 B&W152009E 0.000 Stud Length = 63.250. Procedure
  6. PDI-UT-5.Class A B06.030.007 2-RPV-25-204-07 OM-1201-4 See Corn UT CS 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -Removed.50 B&W152009E 0.000 Stud Length = 63.250. Procedure
  7. PDi-UT-5.Class A B06.030.008 2-RPV-25-204-08 OM-1201-4 See Corn UT CS 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -Removed.50 B&W 1 52009E 0.000 Stud Length = 63.250. Procedure
  8. PDI-UT-5.Class A EOC 21 k CATEGORY B-G-1 Pressure Retaining Boltinc, Greater Than 2 in. In Diameter Reactor Vessel e-DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 f1 Plan Report Page 8 01/16/2006 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B06.030.009 2-RPV-25-204-09 OM-1201-4 See Com UT CS 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -Removed.50 B&W152009E 0.000 Stud Length = 63.250. Procedure
  9. PDI-UT-5.Class A B06.030.01 0 2-RPV-25-204-1 0 OM-1201-4 See Corn UT CS 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -Removed.50 B&W152009E 0.000 Stud Length = 63.250. Procedure
  10. PDI-UT-5.Class A B06.030.011 2-RPV-25-204-11 OM-1201-4 See Com UT CS 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -Removed.50 B&W152009E 0.000 Stud Length = 63.250. Procedure
  11. PDI-UT-5.Class A DB0. 00f 1 2 -D2-PV-25-2')0A4-12 OAM-12014 A S Com "IT CS 6.500 4A0420 R-ator V.ssGI ClosurG Stud Pc. 2255- =fmmoved.50 B&W152009E 0.000 Stud Length = 63.250. Procedure
  12. PDI-UT-5.Class A B06.030.013 2-RPV-25-204-13 OM-1201-4 See Com UT CS 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -Removed.50 B&W152009E 0.000 Stud Length = 63.250. Procedure
  13. PDI-UT-5.Class A B06.030.014 2-RPV-25-204-14 OM-1201-4 See Corn UT CS 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -Removed.50 B&W152009E 0.000 Stud Length = 63.250. Procedure
  14. PDI-UT-5.Class A B06.030.015 2-RPV-25-204-15 OM-1201-4 See Com UT CS 6.500 40420 Reactor Vessel Closure Stud Pc. 25- Removed.50 B&W152009E 0.000 Stud Length = 63.250. Procedure
  15. PDI-UT-5.C!- AI A B06.030.016 2-RPV-25-204-16 OM-1201-4 See Corn UT CS 6.500 40420 Reactor Vessel Closure Stud Pc. 25- Removed.50 B&W152009E 0.000 Stud Length = 63.250. Procedure
  16. PDI-UT-5.Class A B06.030.017 2-RPV-25-204-17 OM-1201-4 See Corn UT CS 6.500 40420 Reactor Vessel Closure Stud Pc. 25- Removed.50 B&W152009E 0.000 Stud Length = 63.250. Procedure
  17. PDI-UT-5.Class A t I EOC 21 CATEGORY B-G-1, Pressure Retain Greater Than 2 in. In Diameter WReator Vessel DUKE ENERGY CORPORATION miq Bolting. INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 Plan Report Page 9 01/16/2006 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS B06.030.018 2-RPV-25-204-18 OM-1201-4 See Corn UT CS 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -Removed.50 B&W152009E 0.000 Stud Length = 63.250. Procedure
  18. PDI-UT-5.Class A B06.030.019 2-RPV-25-204-19 OM-1201-4 See Corn UT CS 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -Removed.50 B&W152009E 0.000 Stud Length = 63.250. Procedure
  19. PDI-UT-5.Class A B06.030.020 2-RPV-25-204-20 OM-1201-4 See Corn UT CS 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -Removed.50 B&W152009E 0.000 Stud Length = 63.250. Procedure
  20. PDI-UT-5.Class A Total B06.030 items: 20 I (EOC 21 DUKE ENERGY CORPORATION CATEGORY B-G-1. Pressure Retaining Bolting, INSERVICE INSPECTION PLAN MANAGEMENT Greater Than 2 in. In Diameter Inservice Inspection Database Management System*Reactor Vessel Oconee 2 N Inservice Inspection Plan for Interval 4 Outag, ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CA e1 AL BLOCKS COMMENTS Plan Report Page 10 01/16/2006
        • Closure Washers, Bushings ****B06.050.001 2-RPV-WASH-BUSH B&W152009E QAL-13 VT-1 CS 9.750 Reactor Vessel Closure Washers and Bushings.50 0.000 Stud Holes 1 thru 20.Class A Total B06.050 Items: 1 Total B06 Items: 41 I I 0-EOC 21 DUKE ENERGY CORPORATION CATEGORY B-G-2. Pressure Retaining Bolting, 2 INSERVICE INSPECTION PLAN MANAGEMENT in. And Less In Diameter Inservice Inspection Database Management System*Pressurizer ITEM NUMBER ID NUMBER Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Plan Report Page 1 1 01/16/2006
        • Bolts, Studs, and Nuts ****B07.020.001 2-PZR-UHB-STUDS B&W149775E QAL-13 VT-1 CS 2.000 0.000 50 Pressurizer Upper Heater Bundle Studs Pc. 75 and Nuts. 16 Studs, Length = 19.312". Examine all studs and nuts.Class A Total B07.020 Items: 1 C EOC 21 DUKE ENERGY CORPORATION CATEGORY B-G-2. Pressure Retaining Bolting. 2 INSERVICE INSPECTION PLAN MANAGEMENT in. And Less In Diameter Inservice Inspection Database Management System Stearn Generators ITEM NUMBER ID NUMBER Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA(THK CAL BLOCKS COMMENTS Plan Report Page 12 01/16/2006
        • Bolts, Studs, and Nuts ****B07.030.001 2-SGA-UMW-STUDS OM-201.S-0001 QAL-1 3 VT-1 SS 2.000 Steam Generator 2A Upper Head Manway Studs 50 OM-201.S-0170 0.000 and Nuts. (16 Studs & Nuts)Class A OM-201.S-0171 Examine all studs and nuts.Stud Length =19.63 inches.B07.030.002 2-SGA-LMW-STUDS OM-201.S-0001 QAL-13 VT-1 SS 2.000 Steam Generator 2A Lower Head Manway Studs 50 OM-201.S-0158 0.000 and Nuts. (16 Studs & Nuts)Class A OM-201.S-0171 Examine all studs and nuts.Stud Length =19.63 inches.Total B07.030 Items: 2 4 Ilf EOC 21 DUKE ENERGY CORPORATION CATEGORY B-G-2, Pressure Retaining Bolting. 2 INSERVICE INSPECTION PLAN MANAGEMENT in. And Less In Diameter Inservice Inspection Database Management System 0131ping Oconee 2 w -Inservice Inspection Plan for Interval 4 Outage 1 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAITHK CAL BLOCKS COMMENTS Plan Report Page 13 01/16/2006
        • Bolts, Studs, and Nuts ****B07.050.001 2-PZR-RC4-STUDS OM-245-2012 QAL-13 VT-1 CS 1.125 Pressurizer EMO Valve 2RC-4 Inlet Flange Studs 50 0.000 W-Z Quadrant.Class A 8 Studs, Length = 8.750". Examine all studs and nuts.Total B07.050 Items: 1 A'-EOC 21 1 l DUKE ENERGY CORPORATION CATEGORY B-G-2, Pressure Retaining Bolting. 2 INSERVICE INSPECTION PLAN MANAGEMENT in. And Less In Diameter Inservice Inspection Database Management System Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Plan Report Page 14 01/16/2006
        • Bolts, Studs, and Nuts ****B07.070.003 2-53A-CF1 3-STUDS OM-245-001 QAL-13 VT-1 CS 1.125 B-Side Core Flood 14" Valve 2CF-13 Bolting.53A O-ISIN4-102A-2.3 0.000 Y Axis. Inspect one of the following valves: 2CF-1 1, Class A 2CF-12,2CF-13, or 2CF-14. Examine all studs and nuts.Total B07.070 Items: Total B07 Items: 1 5 O EOC 21 4-CATEGORY B-J. Pressure Retaining Welds In Pipinq NPS 4 or Larger DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 Plan Report Page 15 01/16/2006 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS**** Circumferential Welds *B09.01 1.001 2-PSL-8 ISI-OCN2-015 NDE-600 UT Ss 10.000 See Corn Pressurizer Surge Piping. Elbow Pc. 80 to Pipe Pc.Circumferential 50 O-ISIN4-100A-2.2 See Corn 1.000 84. Depending upon the examiners qualifications, Class A Stress weld Pipe to procedure PDI-UT-2 may be used in lieu of Elbow procedure NDE-600. If PDI-UT-2 is used, calibration block PDI-UT-2-O should be used.B09.011.001A 2-PSL-8 ISI-OCN2-015 NDE-35 PT SS 10.000 Pressurizer Surge Piping. Elbow Pc. 80 to Pipe Pc.Circumferential 50 O-ISIN4-10OA-2.2 1.000 84.Class A Stress weld Pipe to Elbow B09.011.030 2-PIB2-4 ISI-OCN2-010 NDE-600 UT CS 33.500 See Corn Reactor Coolant Pump 2B2 Suction Piping. Pipe Circumferential 50 OM-1201-966 See Corn 2.330 Pc. 63 to Elbow Pc. 62. Depending upon the elss A es;a ass oa, P teminers niialifications, nrorereim Pni-i IT-1 may iias -)rs weldu *i.,- to ***,o**-e*-

-.-. E. .my Elbow be used in lieu of procedure NDE-600. If PDI-UT-1 is used, calibration block PDI-UT-1 -O should be used.B09.011.030A 2-PIB2-4 ISI-OCN2-010 NDE-25 MT CS 33.500 Reactor Coolant Pump 2B2 Suction Piping. Pipe Circumferential 50 OM-1201-966 2.330 Pc. 63 to Elbow Pc. 62.Class A Stress weld Pipe to Elbow B09.011.203 2LP-189-1 2LP-189 NDE-600 UT SS 10.000 See Com This weld was listed previously as 2-53A-8-1 on iso Circumferential 53A O-ISIN4-102A-2.3 See Com 1.000 2-53A-8(1) until it was transferred to iso 2LP-189.Class A Pipe to Depending upon the examiners qualifications, Elbow Procedure PDI-UT-2 may be used in lieu of Procedure NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-O should be used.B09.011.203A 2LP-189-1 2LP-189 NDE-35 PT SS 10.000 This weld was listed previously as 2-53A-8-1 on iso Circumferential 53A O-ISIN4-102A-2.3 1.000 2-53A-8(1) until it was transferred to iso 2LP-189.Class A Pipe to Elbow B09.011.208 2-53A-8-48 2-53A-8(2) NDE-600 UT SS 14.000 See Com Denendina upon the examiners qualifications. Circumferential Class A 53A 0-ISIN4-102A-2.3 See Com 1.250 Pipe to Elbow--r-- -- xt-ry- ----- a procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, calibration block PDI-UT-2-O should be used. EOC 21 I CATEGORY B-J, Pressure Retaining Welds In Piping NPS 4 or Larger ITEM NUMBER ID NUMBER SYS ISO/DWG NU B09.011.208A 2-53A-8-48 2-53A-8(2) Circumferential 53A O-ISIN4-102A-Class A I DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 MBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS NDE-35 PT SS 14.000 2.3 1.250 Pipe to Elbow I Plan Report Page 16 01/16/2006 B09.011.209 2-53A-8-50 2-53A-8(2) NDE-600 UT SS 14.000 See Corn Depending upon the examiners qualifications, Circumferential 53A O-ISIN4-102A-2.3 See corn 1.250 procedure PDI-UT-2 may be used in lieu of Class A Pipe to procedure NDE-600. If PDI-UT-2 is used, calibration Elbow block PDI-UT-2-O should be used.B09.011.209A 2-53A-8-50 2-53A-8(2) NDE-35 PT SS 14.000 Circumferential 53A O-ISIN4-102A-2.3 1.250 Class A Pipe to Elbow Total B09.01i items: i0 EOC 21 q CATEGORY B-J. Pressure Retaining Welds In Piping Less Than NPS 4 I DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 3ERS PROC INSP REQ MAT/SCH DIAITHK CAL BLOCKS Plan Report Page 17 01/16/2006 ITEM NUMBER ID NUMBER SYS ISO/DWG NUME COMMENTS**** Circumferential Welds B09.021.004 2-PDA1-11 ISI-OCN2-011 NDE-35 PT SS-CS 3.500 Reactor Coolant Pump 2A1 Discharge Piping.Circumferential 50 B&W146829E 0.750 Nozzle Pc. 46 to Safe End Pc. 47.Class A Stress weld Nozzle to This weld was cut out and welded back in EOC-20.Dissimilar Safe End The new weld is also listed as weld 29 on rev .11 of iso 2RC-204.B09.021.010 2-PIB1 -11 ISI-OCN2-009 NDE-35 PT CS-lnconel 3.500 Reactor Coolant Pump 2B1 Suction Piping. Nozzle Circumferential 50 B&W146635E 0.672 Pc. 87 to Safe End Pc. 88.Class A Stress weld Nozzle to Dissimilar Safe End B09.021.123 2-51A-147-17 2-51A-147 NDE-35 PT SS 2.500 Circumferential 51A O-ISIN4-101A-2.1 0.375 Ciass A Pipe to Reducer B09.021.134 2-51A-35-43 2-51A-35 (2) NDE-35 PT SS 2.500 Circumferential 51A O-ISIN4-101A-2.1 0.375 Class A Tee to Valve 2HP-1 B09.021.135 2-51A-35-55 2-51A-35 (2) NDE-35 PT SS 2.500 Circumferential 51A O-ISIN4-101A-2.1 0.375 Class A Tee to Pipe B09.021.136 2-51A-35-56 2-51A-35 (2) NDE-35 PT SS 2.500 Circumferential 51A O-ISIN4-101A-2.1 0.375 Class A Pipe to Elbow BU.U21.201 2LP-15-1 2LP--i 5i NDE-35 PT Ss 3.000 This wid was prpviousy lisited as 2-53A-36-i unil Circumferential 53A O-ISIN4-102A-2.1 0.438 iso 2-53A-36 was redrawn.Class A Valve 2LP-103 to Pipe Total B09.021 Items: 7 EOC 21 CATEGORY B-J. Pressure Retaininq Welds In Piping E1Branch Pipe Connection Welds ITEM NUMBER ID NUMBER DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 Plan Report Page 18 01/16/2006 SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS**** Less Than NPS 4 ****B09.032.004 2-PDB1-12 Branch Class A Stress weld ISI-OCN2-013 50 OM-1201-966 B&W146630E NDE-35 PT SS 12.000 2.250 Reactor Coolant Pump 2B1 Discharge Piping.Pressurizer Spray Nozzle Pc. 51 to Safe End Pc. 49.NPS of Branch Piping is 2.5 inches.Nozzle to Safe End B09.032.201 2LP-151-21 Branch Class A 2LP-151 53A O-ISIN4-102A-2.1 NDE-35 PT SS 3.000 0.438 Pipe to Pipe Isometric 2LP-151 was issued to transfer welds from 2-53A-35. This weld number used to be 2-53A-35-1. Total B09.032 Items: 2 EOC 21 _CATEGORY B-J, Pressure Retaining Welds In IN Piping Inser MSocket Welds E INN M ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS C DUKE ENERGY CORPORATION SERVICE INSPECTION PLAN MANAGEMENT vice Inspection Database Management System Oconee 2 service Inspection Plan for Interval 4 Outage 1 PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Plan Report Page 19 01/16/2006 B09.040.002 2RC-271-13A 2RC-271 NDE-35 PT SS 1.500 This weld was listed previously as 2-50-129-13A Socket 50 O-ISIN4-100A-2.2 0.281 until iso 2-50-129 was deleted and all welds were Class A Tee to tranferred to iso 2RC-271.Pipe B09.040.007 2-50-7-124 2-50-7 (1) NDE-35 PT SS 1.500 Socket 60 O-ISIN4-100A-2.1 0.281 Class A Pipe to Elbow Total B09.040 Items: Total B09 Items: 2 21 jf EOC 21 CATEGORY B-K. Welded Attachments For Vessels, Piping. Pumps. And Valves ITEM NUMBER ID NUMBER SYS ISO/DWC**** Welded Attachments

        • B1 0.020.001 2-50-0-1481 A-H3 0-2RB-25: Hyd Snubber 50 O-ISIN4-1 I DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 0I Plan Report Page 20 01/16/2006 3 NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS 314-01 OOA-2.2 NDE-35 PT NA 2.500 0.154 Calculation No. OSC-1324-06.

Inspect with F01.012.002. Class A B10.020.031 2-53A-0-1479A-H8B Spring Hgr Class A 0-1492C-2(s) 53A O-ISIN4-102A-2.3 NDE-35 PT NA 10.000 1.250 Calculation No. OSC-1 318.Inspect with F01 .012.032.Total B10.020 Items: Total B10 Items: 2 2 1 EOC 21 DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System F CATEGORY B-N-1, Interior Of Reactor Vessel Reactor Vessel ITEM NUMBER Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS Plan Report Page 21 01/16/2006 ID NUMBER**** Vessel Interior ****B13.010.001 2-RPV-INT-SURFACE B&W 1 52008E 50 ISI-OCN2-001 QAL-14 See Corn VT-3 SS 0.000 0.000 Class A Reactor Vessel Interior. Areas to be examined shall include the spaces above and below the Reactor Core that are made accessible for examination by removal of components during normal refueling outages. Reference Framatome Procedure 54-ISI-364-00. Total B13.010 Items: Total B13 Items: 1 1 EOC 21 ^-CATEGORY B-O. Pressure Retaininq Welds In DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 Al-4 Control Rod Housings Reactor Vessel ITEM NUMBER ID NUMBER Plan Report Page 22 01/16/2006 SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS**** Welds in CRD Housing ****B14.010.003 2-RPV-CRD-63WH9 OM-1201-1529 NDE-35 PT SS-Inconel 4.025 CRDM #63 Housing Body to Adapter.50 OM-1201-1530 0.650 Class A Housing Body to Dissimilar Adapter B14.010.006 2-RPV-CRD-63W60 OM-1201-1530 NDE-35 PT SS-CS 5.000 CRDM #63 Base to Motor Tube.50 OM-2201-1085 0.500 Class A Base to Motor Tube B14.010.009 2-RPV-CRD-63 OM-1201-1530 NDE-35 PT SS-CS 4.300 CRDM #63 Motor Tube to Extension. 50 OM-2201 -1085 0.400 Class A Motor Tube to Extension B14.010.012 2-RPV-CRD-63W61 OM-1201-1530 NDE-35 PT SS 4.190 CRDM #63 Extension to Cap.50 OM-2201-1085 0.380 Class A Extension to Cap Total B14.010 Items: Total B14 Items: 4 4 EOC 21 DUKE ENERGY CORPORATION CATEGORY C-B. Pressure Retaining Nozzle INSERVICE INSPECTION PLAN MANAGEMENT Welds In Vessels Inservice Inspection Database Management System LNozzles With Reinforcing Plate in Vessels > 1/2 Oconee 2 in. Nom. Thickness Inservice Inspection Plan for Interval 4 Outage 1 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS**** Reinforcing Plate Welds to Nozzle and Vessel ****Plan Report Page 23 01/16/2006 C02.031.001 2-LPCB-INLET OM-201 -0286 NDE-35 PT SS 16.000 Decay Heat Cooler 2B Inlet Nozzle Reinforcing Circumferential O-ISIN4-102A-2.2 0.625 Plate Welds to Nozzle and Vessel.Class B Nozzle to Shell C02.031.002 2-LPCB-OUTLET NDE-35 PT SS 16.000 Decay Heat Cooler 2B Outlet Nozzle Reinforcing Circumferential OM-201-0286 0.625 Plate Welds to Nozzle and Vessel.Class B O-ISIN4-102A-2.2 Nozzle to Shell Total C02.031 Items: 2 Total C02 Items: 2 Ap-I EOC 21 CATEGORY C-C, Welded Attachments For Vessels, Piping. Pumps. And Valves Pressure Vessels ITEM NUMBER ID NUMBER SYS ISO/DWG NUMI DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 3ERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS C Plan Report Page 24 01/16/2006

        • Welded Attachments
        • C03.010.003 2-RCSR-COOLER-A OM-201-086 NDE-35 PT SS 0.000 Reactor Coolant Seal Return Cooler 2A.O-ISIN4-101A-2.1 0.000 Class B Support Attachment to Shell Total C03.010 Items: 1 EOC 21 I CATEGORY C-C. Welded Attachments For Vessels, Piping. Pumps, And Valves DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 I ITEM NUMBER Plan Report Page 25 01/16/2006 ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS**** Welded Attachments
        • C03.020.001 2-01A-0-1441-H1 2-01-01/sht.1 NDE-25 MT NA 36.000 Calculation No. OSC-440. Inspect with F01.022.001.

Spring Hgr 01A O-ISIN4-122A-2.1 0.500 Class B C03.020.013 2-03A-1439A-RL-0901 2-03A-08/sht.3 NDE-25 MT NA 6.000 Calculation No. OSC-449. Inspect with F01.020.014. Rigid Support 03A O-ISIN4-121D-2.1 0.500 Class B C03.020.021 2-14B-0-1479A-H11E 0-2RB-21410-04 NDE-25 MT NA 8.000 Calculation No. OSC-1325-09. Inspect with Rigid Restraint 14B O-ISIN4-124B-2.2 1.500 F01.021.023. Class B C03.020.045 2-53B-2-0-436E-H1O 0-2AB-25102-02 NDE-35 PT NA 6.000 Calculation No. OSC-481. Inspect with F01.020.071. Rigid Support 53B O-ISIN4-101A-2.3 0.216 Class B C03.020.053 2-54A-3-0-1444-R3 2-54-03/sht.2 NDE-35 PT NA 8.000 Calculation No. OSC-496. Inspect with F01.021.073. Rigid Restraint 54A O-ISIN4-103A-2.1 0.500 Class B C03.020.054 2-54A-3-0-1444-Hi 2-54-1/sht.1 NDE-35 PT NA 8.000 Calculation No. OSC-494. Inspect with F01.020.097. Rigid Support 54A O-ISIN4-103A-2.1 0.500 Class B Total C03.020 Items: 6 Total C03 Items: 7 Av-g9 EOC 21 '-DUKE ENERGY CORPORATION CATEGORY C-F-i. Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS Or Hiah Alloy Pioing Inservice Inspection Database Management System*PiDina Welds >= 3/8 in. Nominal Wall Thickness forPiping > NPS 4 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBE Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 RS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS Plan Report Page 26 01/16/2006 COMMENTS**** Circumferential Weld C05.011.001 2LP-148-16 2LP-148 NDE-600 UT SS 10.000 See Corn This weld was previously listed as 2-53A-8-16 until Circumferential 53A O-ISIN4-102A-2.2 See Com 1.125 iso 2-53A-8(1) was redrawn.Class B Pipe to Depending upon the examiners qualifications, Valve 2LP-47 Procedure PDI-UT-2 may be used in lieu of Procedure NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-O should be used.C05.011.001A 2LP-148-16 2LP-148 NDE-35 PT SS 10.000 This weld was previously listed as 2-53A-8-16 until Circumferential 53A O-ISIN4-102A-2.2 1.125 iso 2-53A-8(1) was redrawn.Class B Pipe to Valve 2LP-47 C05.011.002 2LP-1 48-17 2LP-148 NDE-600 UT SS 10.000 See Corn This weld was previously listed as 2-53A-8-17 until Circumferentiai 53A O-iSiN4-102A-2.2 SeeCom 1.125 1.Class B Pipe to Depending upon the examiners qualifications, Elbow Procedure PDI-UT-2 may be used in lieu of Procedure NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-O should be used.C05.011.002A 2LP-148-17 2LP-148 NDE-35 PT SS 10.000 This weld was previously listed as 2-53A-8-17 until Circumferential 53A O-ISIN4-102A-2.2 1.125 iso 2-53A-8(1) was redrawn.Class B Pipe to Elbow C05.011.003 2LP-148-18 2LP-148 NDE-600 UT SS 10.000 See Corn This weld was previously listed as 2-53A-8-18 until Circumferential 53A O-ISIN4-102A-2.2 See Corn 1.125 iso 2-53A-8(1) was redrawn. Depending upon the Class B Pipe to examiners qualifications, Procedure PDI-UT-2 may Elbow be used in lieu of Procedure NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-O should be used.C05.011.003A 2LP-148-18 2LP-148 NDE-35 PT SS 10.000 This weld was previously listed as 2-53A-8-18 until Circumferential 53A O-ISIN4-102A-2.2 1.125 iso 2-53A-8(1) was redrawn.Class B Pipe to Elbow Total C05.011 Items: 6 A-EOC 21 %_DUKE ENERGY CORPORATION CATEGORY C-F-1, Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS Or Hiah Allov Pining Inservice Inspection Database Management System*Pioinai Welds > 1/5 in. Nom Wall for Pipina >=NPS2and<=NPS4 ITEM NUMBER ID NUMBER SYS ISO/DV Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 Plan Report Page 27 01/16/2006 iG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS**** Circumferential Weld ****C05.021.001 2-RCP-FTR2A-SH-1 NDE-12 RT SS 4.000 Reactor Coolant Pump Seal Supply Filter 2A. Pc.Circumferential 51A OM-201-0473 0.531 10 to Pc. 1.Class B Term end O-ISIN4-101A-2.4 Filter Hub to Filter Housing C05.021.001A 2-RCP-FTR2A-SH-1 NDE-35 PT SS 4.000 Circumferential 51A OM-201-0473 0.531 Class B Term end O-ISIN4-101A-2.4 Filter Hub to Filter Housing C05.021.002 2-RCP-FTR2A-SH-2 NDE-12 RT SS 4.000 Reactor Coolant Pump Seal Supply Filter 2A Pc. 10 Circumferential 51A OM-201-0473 0.531 to Pc. 1.Class B Term end O-ISIN4-101A-2.4 Filter Hub to Fiiter Housing C05.021.002A 2-RCP-FTR2A-SH-2 NDE-35 PT SS 4.000 Circumferential 51A OM-201-0473 0.531 Class B Term end O-ISIN4-101A-2.4 Filter Hub to Filter Housing C05.021.006 2-51A-129-9 2-51A-129 NDE-600 UT SS 4.000 See Coin Depending upon the examiners qualifications, Circumferential 51A O-ISIN4-101A-2.4 See Coin 0.531 Procedure PDI-UT-2 may be used in lieu of Class B Elbow to Procedure NDE-600. If PDI-UT-2 is used, Pipe Calibration Block PDI-UT-2-O should be used.C05.021.006A 2-51A-129-9 2-51A-129 NDE-35 PT SS 4.000 Circumferential 51A O-ISIN4-101A-2.4 0.531 Class B Elbow to Pipe C05.021.024 2-51A-17-100A 2-51A-17 (4) NDE-600 UT SS 4.000 See Coin Depending upon the examiners qualifications, Circumferential 51A O-ISIN4-101A-2.3 See Coin 0.531 Procedure PDi-UT-2 may be used i,-i iieu of Class B Tee to Procedure NDE-600. If PDI-UT-2 is used, Pipe Calibration Block PDI-UT-2-O should be used.C05.021.024A 2-51A-17-100A 2-51A-17 (41 NDE-35 PT SS 4.000 Circumferential Class B 51A 0-1SIN4-101A-2.3 0.531 Tee to Pipe EOC 21 11 It DUKE ENERGY CORPORATION CATEGORY C-F-1. Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS Or High Alloy Piping Inservice Inspection Database Management System L1Pininia Welds > 1/5 in. Nom Wall for Pipina >= Oconee 2 NPS 2 and <= NPS 4 Inservice Inspection Plan for Interval 4 Outage 1 (Plan Report Page 28 01/16/2006 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAITHK CAL BLOCKS COMMENTS C05.021.025 2-51A-17-101 2-51A-17 (4) NDE-600 UT SS 4.000 See Corn Depending upon the examiners qualifications, Circumferential 51A O-ISIN4-101A-2.3 See Corn 0.531 Procedure PDI-UT-2 may be used in lieu of Class B Tee to Procedure NDE-600. If PDI-UT-2 is used, Tee Calibration Block PDI-UT-2-O should be used.C05.021.025A 2-51A-17-101 2-51A-17 (4) NDE-35 PT SS 4.000 Circumferential 51 A O-ISIN4-101A-2.3 0.531 Class B Tee to Tee C05.021.026 2-51A-17-111 2-51A-17 (5) NDE-600 UT SS 4.000 See Corn Depending upon the examiners qualifications, Circumferential 51A O-ISIN4-101A-2.3 See Corn 0.531 Procedure PDI-UT-2 may be used in lieu of Class B Pipe to Procedure NDE-600. If PDI-UT-2 is used, Valve 2HP-128 Calibration Block PDI-UT-2-O should be used.Irt-U-I.;OP tiII-I Uir Ir I I~ PdLI --.J3 F I J t.'Jvl C105.021.0260A 2- -51A-1-11 2-1A1 Li) NI-3rTe4.0 Circumferential 51A O-ISIN4-101A-2.3 0.531 Class B Pipe to Valve 2HP-128 C05.021.027 2HP-227-3 2HP-227 NDE-600 UT SS 4.000 See Corn This weld was listed previously as 2-51A-17-142 Circumferential 51A O-ISIN4-101A-2.3 See Corn 0.531 until iso 2-51A-17(6) was redrawn. Depending upon Class B Pipe to the examiners qualifications, Procedure PDI-UT-2 Valve 2HP-1 17 may be used in lieu of Procedure NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-O should be used.C05.021.027A 2HP-227-3 2HP-227 NDE-35 PT SS 4.000 This weld was listed previously as 2-51A-17-142 Circumferential 51A O-ISIN4-101A-2.3 0.531 until iso 2-51A-17(6) was redrawn.Class B Pipe to Valve 2HP-1 17 C05.021.028 2HP-227-7 2HP-227 NDE-600 UT SS 4.000 See Corn This weld was listed previously as 2-51 A-1 7-146 Circumferential Class B 51A 0-ISIN4-101A-2.3 See Corn 0.531 Pipe to Valve 2HP-148 until iso 2-51A-17(6) was redrawn. Depending upon the examiners qualifications, Procedure PDI-UT-2 may be used in lieu of Procedure NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-O should be used.C05.021.028A 2HP-227-7 Circumferential Class B 2HP-227 51A 0-ISIN4-101A-2.3 NDE-35 PT SS 4.000 0.531 Pipe to Valve 2HP-148 This weld was listed previously as 2-51 A-17-146 until iso 2-51A-17(6) was redrawn. EOC 21 -DUKE ENERGY CORPORATION CATEGORY C-F-i. Pressure Retaininq Welds In INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS Or High Alloy Piping Inservice Inspection Database Management System EPipino Welds > 1/5 in. Nom Wall for Piping >= Oconee 2 NPS 2 and <= NPS 4 Inservice Inspection Plan for Interval 4 Outage 1 t Plan Report Page 29 01/16/2006 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS C05.021.073 2-51A-28-67 2-51A-28 (3) NDE-600 UT SS 2.500 See Corn Depending upon the examiners qualifications, Circumferential 51A O-ISIN4-101A-2.4 See Corn 0.375 Procedure PDI-UT-2 may be used in lieu of Class B Tee to Procedure NDE-600. If PDI-UT-2 is used, Pipe Calibration Block PDI-UT-2-O should be used.C05.021.073A 2-51A-28-67 2-51A-28 (3) NDE-35 PT SS 2.500 Circumferential 51A O-ISIN4-101A-2.4 0.375 Class B Tee to Pipe C05.021.074 2-51A-28-69 2-51A-28 (3) NDE-600 UT SS 2.500 See Corn Depending upon the examiners qualifications, Circumferential 51A O-ISIN4-101A-2.4 See Corn 0.375 Procedure PDI-UT-2 may be used in lieu of Class B Elbow to Procedure NDE-600. If PDI-UT-2 is used, Pipe Calibration Block PDI-UT-2-O should be used.Ci5.021.074A 2-5iA-28-69 2-51A-28 (3) NDE-35 PT SS 2.500 Circumferential 51A O-ISIN4-101A-2.4 0.375 Class B Elbow to Pipe C05.021.075 2-51 A-33-1 0 2-51 A-33 NDE-600 UT SS 2.500 See Corn Depending upon the examiners qualifications, Circumferential 51A O-ISIN4-101A-2.1 See Corn 0.375 Procedure PDI-UT-2 may be used in lieu of Class B Pipe to Procedure NDE-600. If PDI-UT-2 is used, Elbow Calibration Block PDI-UT-2-O should be used.C05.021.075A 2-51A-33-10 2-51A-33 NDE-35 PT SS 2.500 Circumferential 51A O-ISIN4-101A-2.1 0.375 Class B Pipe to Elbow C05.021.076 2-51A-33-13 2-51A-33 NDE-600 UT SS 2.500 See Corn Depending upon the examiners qualifications, Circumferential 51A O-ISIN4-101A-2.1 See Corn 0.375 Procedure PDI-UT-2 may be used in lieu of Class B Elbow to Procedure NDE-600. If PDI-UT-2 is used, Pipe Calibration Block PDI-UT-2-O should be used.C05.021.076A 2-51A-33-13 2-51 A-33 NDE-35 PT SS 2.500 Circumferential 51A O-ISIN4-101A-2.1 0.375 Class B Elbow to Pipe C05.021.081 2-51A-27-3 2-51A-27 (1) NDE-600 UT SS 4.000 See Corn Depending upon the examiners qualifications, Circumferential Class B 51A 0-ISIN4-IOIA-2.4 See Corn 0.531 Elbow to Pipe Procedure PDI-UT-2 may be used in lieu of Procedure NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-O should be used. F EOC 21 'k _DUKE ENERGY CORPORATION CATEGORY C-F-1. Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS Or High Alloy Piping Inservice Inspection Database Management System EPipina Welds > 1/5 in. Nom Wall for Piping >= Oconee 2 NPS 2 and <= NPS 4 Inservice Inspection Plan for Interval 4 Outage 1 Plan Report Page 30 01/16/2006 ITEM NUMBER ID NUMBER C05.021.081A 2-51A-27-3 Circumferential SYS ISO/DWG NUMBERS 2-51A-27 (1)51A O-ISIN4-101A-2.4 PROC NDE-35 INSP REQ MAT/SCH PT SS DIA/THK CAL BLOCKS COMMENTS 4.000 0.531 Class B Elbow to Pipe C05.021.087 2-51A-27-21 2-51A-27 (1) NDE-600 UT SS 4.000 See Corn Depending upon the examiners qualifications, Circumferential 51A O-ISIN4-101A-2.4 See Com 0.531 Procedure PDI-UT-2 may be used in lieu of Class B Pipe to Procedure NDE-600. If PDI-UT-2 is used, Elbow Calibration Block PDI-UT-2-0 should be used.C05.021.087A 2-51A-27-21 2-51A-27 (1) NDE-35 PT SS 4.000 Circumferential 51A O-iSIN4-101A-2.4 0.531 Class B Pipe to Elbow* j

  • n i ,enn
  • irft A D e pefid0....h e ...... Rr.. Aq ua..f.c.t C05.021.093 2-51 A-28-30 2-51 A-28 () NDE-60 U I 4.000 S CoI DepJnInI upon the exaIne.s qua'IIII Circumferential 51A O-ISIN4-10OA-2.4 See Com 0.531 Procedure PDI-UT-2 may be used in lieu of Class B Pipe to Procedure NDE-600. If PDI-UT-2 is used, Valve 2HP-1 34 Calibration Block PDI-UT-2-O should be used.C05.021.093A 2-51A-28-30 2-51A-28 (1) NDE-35 PT SS 4.000 Circumferential 51A O-ISIN4-101A-2.4 0.531 Class B Pipe to Valve 2HP-134 C05.021.099 2HP-212-24 2HP-212 NDE-600 UT SS 2.500 See Com This weld used to be listed as 2-51A-33-24 and was Circumferential 51A O-ISIN4-101A-2.1 See Corn 0.375 shown on isometric 2-51A-33.

Depending upon the Class B Pipe to examiners qualifications, Procedure PDI-UT-2 may Elbow be used in lieu of Procedure NDE-600. If PDI-UT-2 is used, Calibration Block PDI-UT-2-O should be used.0fl5_091 .099A 2HP-?12-94 9HP-212 NDE-35 PT SS 2.500 This weld used to be listed as 2-51A-33-24 and was Circumferential 51A O-ISIN4-101A-2.1 0.375 shown on isometric 2-51A-33.Class B Pipe to Elbow Total C05.021 Items: 32 r EOC 21 %_DUKE ENERGY CORPORATION CATEGORY C-F-i. Pressure Retaininq Welds In INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS Or High Alloy Piping Inservice Inspection Database Management System Mocket Welds Oconee 2* Inservice Inspection Plan for Interval 4 Outage 1 Plan Report Page 31 01/16/2006 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS C05.030.001 2-51 B-1 8-48 2-51 B-1 8 NDE-35 PT SS 2.000 Socket 51 B O-ISIN4-101A-2.2 0.154 Class B Pipe to Elbow C05.030.007 2LP-98-10 2LP-98 NDE-35 PT SS 10.000 Socket 53B O-ISIN4-102A-2.2 0.375 Class B Flange to Reducer C05.030.008 2LP-97-13 2LP-97 NDE-35 PT SS 10.000 Socket 53B O-ISIN4-102A-2.2 0.375 Class B OM 201-286 Flange to Reducer C05.030.009 2HP-451-44 2HP-451 NDE-35 PT SS 4.000 This weld was listed previously as 2-51A-17-44 on Socket 51A O-ISIN4-101A-2.3 0.237 iso 2-51A-17(1) until it was transferred to iso Class B Term end Elbow to 2HP-451.Flange Total C05.030 Items: 4 EOC 21 IV DUKE ENERGY CORPORATION CATEGORY C-F-1, Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Austenitic SS Or High Alloy Piping Inservice Inspection Database Management System EPPine Branch Connections of Branch Piping >= Oconee 2 NPS 2 Inservice Inspection Plan for Interval 4 Outage 1 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS k Plan Report Page 32 01/16/2006

        • Circumferential Weld ****C05.041.001 2LP-96-13 2LP-96 NDE-35 PT SS 6.000 Branch 53B O-ISIN4-102A-2.2 0.280 Class B Pipe to Pipe Total C05.041 Items: 1 EOC 21 I k DUKE ENERGY CORPORATION CATEGORY C-F-2. Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Carbon Or Low Alloy Steel PiDinai Inservice Inspection Database Management System*Pioin, Welds >= 3/8 in. Nominal Wall Thickness Mfor Piping > NPS 4 Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 RS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS Plan Report Page 33 01/16/2006 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBE COMMENTS**** Circumferential Weld ****C05.051.007 2MS-124-69V 2MS-124 NDE-600 UT CS 24.000 See Corn S/G 2A Main Steam Nozzle to Reducer weld.Circumferential 01A O-ISIN4-122A-2.1 See Coin 0.969 Depending upon the examiners qualifications, Class B Term end Reducer to Procedure PDI-UT-1 may be used in lieu of Nozzle S/G 2A Procedure NDE-600. If PDI-UT-1 is used, Calibration Block PDI-UT-1-O should be used.C05.051.007A 2MS-124-69V 2MS-124 NDE-25 MT CS 24.000 S/G 2A Main Steam Nozzle to Reducer weld.Circumferential 01A O-lSiN4-122A-2.1 0.969 Class B Term end Reducer to Nozzle S/G 2A C05.051.008 2MS-124-72V 2MS-124 NDE-600 UT CS 24.000 See Corn S/G 2A Main Steam Nozzle to Reducer weld.Circumferential 01A O-ISIN4-122A-2.1 See Corn 0.969 Depending upon the examiners qualifications, Class B Term end ReduceIr to P-ocedure PD!-UT-1 may be used in lieu nf Nozzle S/G 2A Procedure NDE-600. If PDI-UT-1 is used, Calibration Block PDI-UT-1 -0 should be used.C05.051.008A 2MS-124-72V 2MS-124 NDE-25 MT CS 24.000 S/G 2A Main Steam Nozzle to Reducer weld.Circumferential 01A O-ISIN4-122A-2.1 0.969 Class B Term end Reducer to Nozzle S/G 2A C05.051.026 2-14B-48-109 2-14B-48 NDE-600 UT CS 8.000 See Corn Flange at valve 2LPSW-21.Circumferential 14B O-ISIN4-124B-2.2 See Corn 0.500 Depending upon the examiners qualifications, Class B Flange to Procedure PDI-UT-1 may be used in lieu of Pipe Procedure NDE-600. If PDI-UT-1 is used, Calibration Block PDI-UT-1-O should be used.C05.051.026A 2-14B-48-109 2-14B-48 NDE-25 MT CS 8.000 Flange at valve 2LPSW-21.Circumferential 14B O-ISIN4-124B-2.2 0.500 Class B Flange to Pipe C05.051.027 2-14B-48-1 11 2-144B-48 NDE-600 UT CS 6.000 See Corn Depending upon the examiners qualifications, Circumferential 14B O-ISIN4-124B-2.2 See Corn 0.432 Procedure PDI-UT-1 may be used in lieu of Class B Tee to Procedure NDE-600. If PDI-UT-1 is used, Flange Calibration Block PDI-UT-1-O should be used.C05.051.027A 2-14B-48-111 2-14B-48 NDE-25 MT CS 6.000 Circumferential Class B 14B 0-ISIN4-124B-2.2 0.432 Tee to Flange Afp dr~T EOC 21 -w DUKE ENERGY CORPORATION CATEGORY C-F-2, Pressure Retaining Welds In INSERVICE INSPECTION PLAN MANAGEMENT Carbon Or Low Alloy Steel Piping Inservice Inspection Database Management System PMPini Welds >= 3/8 in. Nominal Wall Thickness Oconee 2 for Piping > NPS 4 Inservice Inspection Plan for Interval 4 Outage 1 Plan Report Page 34 01/16/2006 ITEM NUMBER ID NUMBER C05.051.028 2-14B-48-112 Circumferential SYS ISO/DWG NUMBERS 2-144B-48 14B O-ISIN4-124B-2.2 PROC NDE-600 See Corn INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS UT CS 6.000 See Corn 0.432 Flange to Pipe Depending upon the examiners qualifications, Procedure PDI-UT-1 may be used in lieu of Procedure NDE-600. If PDl-UT-1 is used, Calibration Block PDI-UT-1-O should be used.Class B C05.051.028A 2-14B-48-112 2-14B-48 NDE-25 MT CS 6.000 Circumferential 14B O-ISIN4-124B-2.2 0.432 Class B Flange to Pipe C05.051.029 2-14B-48-3 2-14B-48 NDE-600 UT CS 8.000 See Corn Depending upon the examiners qualifications, Circumferential 14B O-ISIN4-124B-2.2 See Coin 0.500 Procedure PDl-UT-1 may be used in lieu of Class B Elbow to Procedure NDE-600. If PDl-UT-1 is used, Elbow Calibration Block PDI-UT-1-O should be used.C05.051.029A 2-14B-4O-3 2-1 4B--O lvii 8.000 Circumferential 14B O-lSiN4-124B-2.2 0.500 Class B Elbow to Elbow C05.051.030 2-14B-48-4 2-14B-48 NDE-600 UT CS 8.000 See corn Depending upon the examiners qualifications, Circumferential 14B O-ISIN4-124B-2.2 See Corn 0.500 Procedure PDI-UT-1 may be used in lieu of Class B Elbow to Procedure NDE-600. If PDI-UT-1 is used, Pipe Calibration Block PDI-UT-1-O should be used.C05.051.030A 2-14B-48-4 2-14B-48 NDE-25 MT CS 8.000 Circumferential 14B O-ISIN4-124B-2.2 0.500 Class B Elbow to Pipe-Total C05.051 Items: Total C05 Items: 14 57 I ACl EOC 21 CATEGORY D-A. Welded Attachments For Vessels. Piping. Pumps. And Valves ITEM NUMBER ID NUMBER SYS I'DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 Plan Report Page 35 01/16/2006 SO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS**** Welded Attachments
        • D01.020.013 2-03A-1 1439B-H-12 Rigid Restraint Class C 2-03A-06/sht.3 03A O-ISIN4-121 D-2.1 QAL-13 VT-1 NA 6.000 0.216 Calculation No. OSC-459. Inspect with F01.031.022.

D01.020.014 Class C 2-03A-1 1439B-H31 Spring Hgr 2-03A-05/sht.4 03A 0-lSIN4-121 D-2.1 QAL-1 3 VT-1 NA 6.000 0.500 Calculation No. OSC-447. Inspect with F01.032.011. D01.020.031 Class C 2-07A-6-0-1400A-H56 Spring Hgr 0-2TB-20701 -01 07A O-ISIN4-121A-2.8 QAL-13 VT-1 NA 12.000 0.750 Calculation No. OSC-467. Inspect with F01.032.021. D01.020.051 0-13-447A-H7000 4-13-03/sht.1 QAL-13 VT-1 NA 16.000 Calculation No. OSC-1224-25. Inspect with Rigid Restraint 13 O-ISIN4-133A-2.5 1.000 F01.031.051. Class C D01 .020.061 2-14B-0-1436A-H28 2-14-06/sht.3 QAL-13 VT-1 NA 16.000 Calculation No. OSC-475. Inspect with F01.032.51. Spring Hgr 14B O-ISIN4-124B-2.1 0.187 Class C Total D01.020 Items: Total D01 Items: 5 5 EOC 21 4-CATEGORY F-A. Supports DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS_9C chass 1 Piping Supports ITEM NUMBER ID NUMBER Plan Report Page 36 01/16/2006 COMMENTS**** Category A, One-Directional

        • F01.010.015 2-51A-0-1479A-H9B 2-51-24 QAL-14 VT-3 NA 2.500 Calculation No. OSC-1 323.Rigid Support 51A O-ISIN4-101A-2.4 0.500 HPI West Coolant Loop.Class A F01.010.016 2-51A-0-1479A-H4A 0-2RB-25315-04 OAL-14 VT-3 NA 2.500 Calculation No. OSC-1324-06.

Rigid Support 51A O-ISIN4-101A-2.4 0.375 HPI East Coolant Loop.Class A Total F01.010 Items: 2**** Category B, Multi-Directional Fo1 011 032 2-53A-0-1481A-H28C 0-2RB-25314-02 OAL-14 VT-3 NA 1.500 Calculation No. OSC-1324-06. Rigid Restraint 53A O-ISIN4-100A-2.2 0.250 Class A Total F01.011 Items: 1**** Category C, Thermal Movement F01.012.002 2-50-0-1481A-H3 0-2RB-25314-01 OAL-14 VT-3 NA 2.500 Calculation No. OSC-1324-06. Hyd Snubber 50 O-ISIN4-100A-2.2 0.154 Class A F01.012.032 2-53A-0-1479A-H8B 0-1492C-2(s) QAL-14 VT-3 NA 10.000 Calculation No. OSC-1318.Spring Hgr 53A O-ISIN4-102A-2.3 1.250 Class A Total FU1.012 items: 2 EOC 21 I CATEGORY F-A, Supports DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 WC~s 2 Piping uports Plan Report Page 37 01/16/2006 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS**** Category A, One-Directional

        • F01.020.002 2-01A-0-1401 B-H21 Rigid Support Class B 2-01-01/sht.2 01A O-ISIN4-122A-2.1 QAL-14 VT-3 NA 36.000 0.000 Calculation No. OSC-440.Inspect with item number H04.001.044.

F01.020.014 2-03A-1439A-RL-0901 2-03A-08/sht.3 QAL-14 VT-3 NA 6.000 Calculation No. OSC-449. Inspect with Rigid Support 03A O-ISIN4-121D-2.1 0.500 C03.020.013. Class B F01.020.049 2-51A-3-0-1439A-H77 0-2AB-25106-01 QAL-14 VT-3 NA 4.000 Calculation No. OSC-483.Rigid Support 51A O-ISIN4-101A-2.1 0.000 Class B F01.020.054 2-51A-435C-DE008 2-51-18/sht.3 QAL-14 VT-3 NA 4.000 Calculation No. OSC-1 023.Rigid Support 51A O-ISIN4-101A-2.4 0.000 Class B F01.020.071 2-53B-2-0-436E-H1O 0-2AB-25102-02 QAL-14 VT-3 NA 6.000 Calculation No. OSC-481. Inspect with Rigid Support 53B O-ISIN4-101A-2.3 0.216 C03.020.045. Class B F01.020.076 2-53B-0-435B-DE016 0-2AB-25301-03 QAL-14 VT-3 NA 10.000 Calculation No. OSC-487.Rigid Support 53B O-ISIN4-102A-2.2 0.000 Class B F01.020.091 2-54A-435B-DE15 0-2AB-25301 -01 QAL-14 VT-3 NA 10.000 Calculation No. OSC-487.Rigid Support 54A O-ISIN4-102A-2.1 0.125 Class B F01.020.097 2-54A-3-0-1444-H1 2-54-1/sht.1 QAL-14 VT-3 NA 8.000 Calculation No. OSC-494. Inspect with Rigid Support 54A O-ISIN4-103A-2.1 0.500 C03.020.054. Class B EOC 21 CATEGORY F-A, Supports DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 M~!s2 PipingSuports Plan Report Page 38 01/16/2006 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIAITHK CAL BLOCKS COMMENTS F01.020.102 2-56-438C-DE008 4-56-02/sht.5 QAL-14 VT-3 NA 8.000 Calculaton No. OS-421.Rigid Support 56 O-ISIN4-104A-1.1 0.000 Class B Total F01.020 Items: 9**** Category B, Multi-Directional F01.021.023 2-14B-0-1479A-H11E 0-2RB-21410-04 QAL-14 VT-3 NA 8.000 Calculation No. OSC-1325-09. Inspect with Rigid Restraint 14B O-ISIN4-124B-2.2 1.500 C03.020.021. Class B F01.021.028 2-14B-0-1439A-DE193 4-14-04/sht.3 QAL-14 VT-3 NA 8.000 Calculation No. OSC-474.Rigid Restraint 14B O-ISIN4-124B-2.2 0.000 Class B F01.021.053 2-51 B-0-436J-DE01 9 0-2AB-25108-01 QAL-14 VT-3 NA 2.500 Calculation No. OSC-485.Rigid Restraint 51B O-ISIN4-101A-2.2 0.000 Class B F01.021.063 2-53B-5-0-444-R12 0-2AB-25302-01 QAL-14 VT-3 NA 10.000 Calculation No. OSC-493.Rigid Restraint 53B O-ISIN4-102A-2.2 0.000 Class B F01.021.073 2-54A-3-0-1444-R3 2-54-03/sht.2 QAL-14 VT-3 NA 8.000 Calculation No. OSC-496. Inspect with Rigid Restraint 54A O-ISIN4-103A-2.1 0.500 C03.020.053. Class B Total F01.021 Items: 5**** Category C, Thermal Movement F01.022.001 2-01A-0-1441-Hi 2-01-01/sht.1 QAL-14 VT-3 NA 36.000 Calculation No. OSC-440. Inspect with Spring Hgr 01A O-ISIN4-122A-2.1 0.500 C03.020.001. Class B EOC 21 1-CATEGORY F-A. Supports (DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 WCgas2 PipingSuports Plan Report Page 39 01/16/2006 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS F01.022.011 2-03-0-1479A-H2A 0-1490B-4(S) OAL-14 VT-3 NA 14.000 Calculation No. OSC-1313-06(Vol.B). Constant Support 03 O-ISIN4-121 B-2.3 0.000 Class B 2-03-05/sht.3 F01.022.043 2-51A-3-0-1444A-H75 0-2AB-25106-01 OAL-14 VT-3 NA 4.000 Calculation No. OSC-483.Spring Hgr 51A O-ISIN4-101A-2.1 0.000 Class B F01.022.062 2-54A-3-0-435B-R101 2-54-1/sht.1 QAL-14 VT-3 NA 8.000 Calculation No. OSC-494.Hyd Snubber 54A O-ISIN4-103A-2.1 0.000 Class B Totai FOi.022 items: 4 EOC 21 I CATEGORY F-A. Supports I DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 M~!as3 PipingSupport~s Plan Report Page 40 01/16/2006 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS**** Category A, One-Directional

        • F01.030.001 2-O1A-4-0-1400H-DJB1001 2-01-06/sht.2 QAL-14 VT-3 NA 6.000 Calculation No. OSC-445.Rigid Support 01A O-ISIN4-122A-2.4 0.000 Class C F01.030.012 2-03A-1-0-1400A-H108 0-2TB-203A12-01 QAL-14 VT-3 NA 6.000 Calculation No. OSC-1213.Rigid Support 03A O-ISIN4-121D-2.1 0.000 Class C F01.030.018 2-03A-1-0-1400A-H88 0-2TB-203A12-01 QAL-14 VT-3 NA 6.000 Calculation No. OSC-1213.Rigid Support 03A O-ISIN4-121D-2.1 0.000 Class C F01.030.023 2-03A-1401B-DE009 2-03A-05/sht.5 QAL-14 VT-3 NA 6.000 Calculation No. OSC-447.Rigid Support 03A O-ISIN4-121D-2.1 0.000 Class C F01.030.041 2-07A-6-0-1400A-H58 0-2TB-20701

-01 QAL-14 VT-3 NA 12.000 Calculation No. OSC-467.Rigid Support 07A O-ISIN4-121A-2.8 0.000 Class C Total F01.030 Items: 5 Category B, Multi-Directional F01.031.012 2-03A-1-0-1401A-SR3 2-03A-05/sht.5 QAL-14 VT-3 NA 6.000 Calculation No. OSC-447.Rigid Restraint 03A O-ISIN4-121 D-2.1 0.000 5:!ais C F01.031.016 2-03A-1-0-1400A-H73 0-2TB-203A1 -01 QAL-14 VT-3 NA 6.000 Calculation No. OSC-1212.Rigid Restraint 03A 0-ISIN4-121D-2.1 0.000 Class C F01.031.022 2-03A-1-0-1439B-H12 2-03A-06/sht.3 QAL-14 VT-3 NA 6.000 Calculation No. OSC-459. Inspect with Rigid Restraint 03A 0-ISIN4-121D-2.1 0.216 D01.020.013. Class C EOC 21 CATEGORY F-A. Supports I DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 WlIas3 PipingSupports Plan Report Page 41 01/16/2006 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS F01 .031.051 0-13-447A-H7000 4-13-03/sht.1 QAL-14 VT-3 NA 16.000 Calculation No. OSC-1224-25. Inspect with Rigid Restraint 13 O-ISIN4-133A-2.5 1.000 D01.020.051. Class C Total F01.031 Items: 4**** Category C, Thermal Movement F01.032.011 2-03A-1-0-1439B-H31 2-03A-05/sht.4 QAL-14 VT-3 NA 6.000 Calculation No. OSC-447. Inspect with Spring Hgr 03A O-ISIN4-121D-2.1 0.500 D101.020.014. Class C F01.032.021 2-07A-6-0-1400A-H56 0-2TB-20701 -01 QAL-14 VT-3 NA 12.000 Calculation No. OSC-467. Inspect with Spring Hgr 07A O-ISIN4-121A-2.8 0.750 D01.020.031. Class C F01.032.041 2-13-7-0-1400A-H9 2-07-02/sht.1 QAL-14 VT-3 NA 12.000 Calculation No. OSC-471.Spring Hgr 13 O-ISIN4-133A-2.2 0.000 Class C F01.032.051 2-14B-0-1436A-H28 2-14-06/sht.3 QAL-14 VT-3 NA 16.000 Calculation No. OSC-475. Inspect with Spring Hgr 14B O-ISIN4-124B-2.1 0.187 D01.020.061. Class C Total F01.032 Items: 4 EOC 21 T-CATEGORY F-A, Supports I-DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 ESurports Other Than Piping Supports Plan Report Page 42 01/16/2006 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS**** Class 1, 2, and 3 ****F01.040.003 2-PZR-SKIRT ISI-OCN2-002 QAL-14 VT-3 CS 0.000 Pressurizer Support Stand. Additional Drawing O-ISIN4-10OA-2.2 0.000 OM-1201-858. Class A OM-1201-456 F01.040.005 2-DHRC-A OM-201-286 QAL-14 VT-3 NA 0.000 Decay Heat Removal Cooler 2A Support. Support is 0-ISIN4-102A-2.2 0.000 located on Class C side of Heat Exchanger. Class C F01.040.006 2-50-RCPM-H6604 OM-201.D-003 QAL-14 VT-3 NA 0.000 Reactor Coolant Pump 2A1 Motor Support.Constant Support O-ISIN4-100A.2.1 0.000 Class A F01.040.012 2-LPI-PU-A OM-1201-1121 QAL-14 VT-3 NA 0.000 Low Pressure Injection Pump 2A Support Pad &O-ISIN4-102A-2.2 0.000 Legs.Class B OM-201-1704 F01.040.024 2-LDFTR-A OM-201-0128 QAL-14 VT-3 NA 0.000 Letdown Filter 2A Support.O-ISIN4-101A-2.1 0.000 The examination in outage 1 does not count in the Class B percentages. Work Order 98674855 was written to perform this exam in outage 1.The exam scheduled for outage 6 will count in percentages to meet Section Xl requirements. F01.040.029 2-RB-CC-A OM-201-3142 QAL-14 VT-3 NA 0.000 Reactor Building Cooling Coils 2A. Additional O-ISIN4-124B-2.2 0.000 drawing OM-235-0514. Class B OM-235-0513 Total F01.040 Items: 6 Total FOl Items: 42 Total F01 Items: 42 r EOC 21 CATEGORY ELC, Elective Inspections DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System I ITEM NUMBER Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS Plan Report Page 43 01/16/2006 ID NUMBER COMMENTS H03.001.001 2FDW-225-22B 2FDW-225 NDE-600 UT CS 24.000 This weld used to be listed as 2-03-18-22B and was Circumferential 03 O-ISIN4-121B-2.3 NDE-940 1.219 shown on isometric 2-03-18.Class B Elbow to Procedure NDE-600 should be used for angle beam Valve 2FDW-46 inspection and Procedure NDE-940 should be used for thickness measurements on this weld.Inspection results should be forwarded to Timothy D. Brown of the Oconee Design Basis Group.H03.001.002 2-03-18-22C 2-03-18 (1) NDE-600 UT CS 24.000 Procedure NDE-600 should be used for angle beam Circumferential 03 O-ISIN4-121B-2.3 NDE-940 1.219 inspection and Procedure NDE-940 should be used Class C Pipe to for thickness measurements on this weld.Valve 2FDW-46 Inspection results should be forwarded to Timothy D. Brown of the Oconee Design Basis Group.H03.001.003 2-03-18-23A 2-03-18 (1) NDE-600 UT CS 24.000 Procedure NDE-600 should be used for angle beam Circumferential 03 O-ISIN4-121 B-2.3 NDE-940 1.219 inspection and Procedure NDE-940 should be used Class C Pipe to for thickness measurements on this weld.Elbow Inspection results should be forwarded to Timothy D. Brown of the Oconee Design Basis Group.H03.001.004 2-03-18-23G 2-03-18 (1) NDE-600 UT CS 24.000 Weld 2-03-18-23A is a Pipe to elbow weld located Circumferential 03 O-ISIN4-121B-2.3 NDE-940 1.219 on iso 2-03-18(1). Weld 2-03-18-23G is a Grinnell Class C Elbow to Subassembly (elbow to pipe) weld located on the Pipe opposite end of the elbow from weld 1-03-18-23A. Procedure NDE-600 should be used for angle beam inspection and Procedure NDE-940 should be used for thickness measurements on this weld.Inspection results should be forwarded to Timothy D. Brown of the Oconee Design Basis Group.H03.001.005 2-03-18-24 2-03-18 (1) NDE-600 UT CS 24.000 Procritra NCF-RAn shnioud hp iupsd fnr annie beam Circumferential 03 O-ISIN4-121B-2.3 NDE-940 1.219 inspection and Procedure NDE-940 should be used Class C Pipe to for thickness measurements on this weld.Elbow Inspection results should be forwarded to Timothy D. Brown of the Oconee Design Basis Group.H03.001.006 2-03-18-24G 2-03-18 (1) NDE-600 UT CS 24.000 Weld 2-03-18-24 is a Pipe to elbow weld located on Circumferential 03 O-ISIN4-121B-2.3 NDE-940 1.219 Class C Elbow to Pipe iso 2-03-18(1). Weld 2-03-18-24G is a Grinnell Subassembly (elbow to pipe) weld located on the opposite end of the elbow from weld 1-03-18-24 Procedure NDE-600 should be used for angle beam ,le-EOC 21 CATEGORY ELC. Elective Inspections 4 DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 I ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS Plan Report Page 44 01/16/2006 COMMENTS inspection and Procedure NDE-940 should be used for thickness measurements on this weld.Inspection results should be forwarded to Timothy D. Brown of the Oconee Design Basis Group.Total H03.001 Items: 6 Total H03 Items: 6 EOC 21 CATEGORY ELC. Elective Inspections DUKE ENERGY CORPORATION INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 Plan Report Page 45 01/16/2006 ITEM NUMBER ID NUMBER SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS COMMENTS H04.001.001 2-03-0-1439B-H62 2-03-01/sht.1 QAL-14 VT-3 NA 24.000 Calculation No. OSC-454.Rigid Support 03 O-ISIN4-121 B-2.3 0.375 Inspect with item number H04.001.001A. Class B H04.001.001A 2-03-0-1439B-H62 2-03-01/sht.1 NDE-35 PT NA 24.000 Calculation No. OSC-454.Rigid Support 03 O-ISIN4-121B-2.3 0.375 Inspect along with item number H04.001.001. Class B Perform a Surface exam on the attachment welds.Note: Magnetic Particle examinations (with the use of procedure NDE-25) may be performed on carbon steel material in lieu of or in conjunction with liquid penetrant examinations. H04.001.003 2-03-0-1439B-H53 2-03-011sht.1 QAL-14 %'T-3 NA 24.000 CaIcu!atinn No, OSG-454.Spring Hgr 03 O-ISIN4-121B-2.3 0.000 Class C H04.001.005 2-03-0-551-H51 2-03-01/sht.1 QAL-14 VT-3 NA 24.000 Calculation No. OSC-454.Rigid Support 03 O-ISIN4-121B-2.3 1.500 Inspect with item number H04.001.005A Class C H04.001.005A 2-03-0-551-H51 2-03-01/sht.1 NDE-35 PT NA 24.000 Calculation No. OSC-454.Rigid Support 03 O-ISIN4-121B-2.3 1.500 Inspect along with item number H04.001.005. Class C Perform a Surface exam on the attachment welds.Note: Magnetic Particle examinations (with the use of procedure NDE-25) may be performed on carbon steel material in lieu of or in conjunction with liquid penetrant examinations. H04.001.006 2-03-0-1401A-R8 2-03-01/sht.1 QAL-14 VT-3 NA 24.000 Calculation No. OSC-454.Rigid Support 03 O-ISIN4-121 B-2.3 0.322 Inspect with item number H04.001.006A. Class C H04.001.006A 2-03-0-1401A-R8 2-03-01/sht.1 NDE-35 PT NA 24.000 Calculation No. OSC-454.Rigid Support Class C 03 O-ISIN4-121 B-2.3 0.322 Inspect along with item number H04.001.006. Perform a Surface exam on the attachment welds.Note: Magnetic Particle examinations (with the use of procedure NDE-25) may be performed on carbon steel material in lieu of or in conjunction with liquid I!0F EOC 21 .CATEGORY ELC. Elective Insw DUKE ENERGY CORPORATION ections INSERVICE INSPECTION PLAN MANAGEMENT Inservice Inspection Database Management System Oconee 2 Inservice Inspection Plan for Interval 4 Outage 1 SYS ISO/DWG NUMBERS PROC INSP REQ MAT/SCH DIA/THK CAL BLOCKS I ITEM NUMBER Plan Report Page 46 ,01/16/2006 ID NUMBER COMMENTS penetrant examinations. H04.001.007 2-03-0-551-H50 2-03-01/sht.1 QAL-14 VT-3 NA 24.000 Calculation No. OSC-454.Spring Hgr 03 O-ISIN4-121B-2.3 0.500 Inspect with item number H04.001.007A. Class C H04.001.007A 2-03-0-5511-H50 2-03-01/sht.1 NDE-35 PT NA 24.000 Calculation No. OSC-454.Spring Hgr 03 O-ISIN4-121B-2.3 0.500 Inspect along with item number H04.001.007. Class C Perform a Surface exam on the attachment welds.Note: Magnetic Particle examinations (with the use of procedure NDE-25) may be performed on carbon steel material in lieu of or in conjunction with liquid penetrant examinations. H04.001.044 2-01A-0-1401B-H21 2-01-01/sht.2 QAL-14 VT-3 NA 36.000 Calculation No. OSC-440.Rigid Support 01A O-ISIN4-122A-2.1 0.000 Inspect with item number F01.020.002. Class B Total H04.001 Items: 10 Total H04 Items: 10

4.0 Results

Of Inspections Performed The results of each examination shown in the final Inservice Inspection Plan (Section 3 of this report) are included in this section. The completion date and status for each examination are shown. All examinations revealing reportable indications and any corrective action required as a result are described in further detail in Subsections 4.1 and 4.2. Corrective measures performed and limited examinations are described in further detail in Subsections 4.3 and 4.4.The information shown below is a field description for the reporting format included in this section of the report: Item Number ID Number Sys Insp Date= ASME Section Xl Tables IWB-2500-1 (Class 1), IWC-2500-1 (Class 2), IWF-2500-1 (Class 1 and Class 2), Augmented Requirements = Unique Identification Number= Component System Identification = Date of Examination Insp Status Insp Limited Geo. Ref.(Geometric Reflector applies only to UT)RFR (Relief Request)Comments= CLR Clear REC Recordable REP Reportable = Indicates inspection was limited.Coverage obtained is listed= Y Yes N No= Y Yes N No= General and/or Detail Description EOC 21 Refueling Outage Report Oconee Unit 2 Section 4 Page 1 of 2 Revision 0 January 16, 2006

4.1 Reportable

Indications EOC 21 (Outage 1) did not have any reportable indications during this report period.4.2 Corrective Action Corrective action is action taken to resolve flaws and relevant conditions, including supplemental examinations, analytical evaluations, repair / replacement activities, and corrective measures. There were no problems that required corrective action during this report period.4.3 Corrective Measures Corrective measures are actions (such as maintenance) taken to resolve relevant conditions, but not including supplemental examinations, analytical evaluations, and repair / replacement activities. Any corrective measures performed for examinations associated with this report period will be shown on the examination data sheets which are on file at the Duke Energy Corporate Office in Charlotte, North Carolina.4.4 Limited Examinations Limited examinations (i.e., less than or equal to 90% of the required examination coverage obtained) identified during EOC 21 (Outage 1) are shown in the table below.A Request for Relief will be submitted to seek NRC acceptance of the limited coverage for the items listed in the table below.Item Number Description of Limitation B03.150.001 Coverage limitation (29.26%)B03.150.002 Coverage limitation (29.26%)C05.01 1.001 Coverage limitation (72.40%)C05.021.026 Coverage limitation (37.50%)C05.021.027 Coverage limitation (37.50%)C05.021.028 Coverage limitation (37.50%)C05.021.073 Coverage limitation (79.15%)EOC 21 Refueling Outage Report Oconee Unit 2 Section 4 Page 2 of 2 Revision 0 January 16, 2006 Ar-t I EOC 21 Plant: Oconee 2 DUKE ENERGI )RPORATION QUALITY ASSURANCE TECHNICAL SERVICES In-Service Inspection Database Management System Oconee 2 Inservice Inspection Listing Interval 4 Outage 1 TE INSP STATUS INSP LIMITED GEO REF RFR)05 REC --- N N ITEM NUMBER B02.011.001 B02.012.001 B03.150.001 B03.150.002 B03.160.001 B03.160.002 B06.010.001 B06.0i0.002 B06.010.003 B06.010.004 B06.010.005 B06.010.006 B06.010.007 B06.010.008 B06.010.009 B06.01 0.010 B06.010.011 B06.010.012 B06.010.013 B06.010.014 B06.010.015 B06.010.016 B06.010.017 B06.010.018 B06.010.019 B06.010.020 B06.030.001 B06.030.002 B06.030.003 B06.030.004 ID NUMBER 2-PZR-WP76 2-PZR-WP1-1 2-LDCA-I N-V1 2-LDCA-OUT-V2 2-LDCA-IN-V1 2-LDCA-OUT-V2 2-RPV-26-204-01 2-RPv-26-204-02 2-RPV-26-204-03 2-RPV-26-204-04 2-RPV-26-204-05 2-RPV-26-204-06 2-RPV-26-204-07 2-RPV-26-204-08 2-RPV-26-204-09 2-RPV-26-204-1 0 2-RPV-26-204-11 2-RPV-26-204-12 2-RPV-26-204-13 2-RPV-26-204-14 2-RPV-26-204-15 2-RPV-26-204-16 2-RPV-26-204-17 2-RPV-26-204-18 2-RPV-26-204-62 2-RPV-26-204-20 2-RPV-25-204-01 2-RPV-25-204-02 2-RPV-25-204-03 2-RPV-25-204-64 SYSTEM INSP DA 50 10/28/2(Run D Page 1 01/16/2006 COMMENTS The recordable indication that was found was acceptable per ASME Section Xl, Paragraph IWB-3510, of the 1998 Edition through the 2000 Addenda.PIP 0-05-06919 was written to document problems found during the review of documentation from a previous exam that was performed in 1996.50 51A 51A 51A 51A 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 10/28/2005 11/01/2005 11/01/2005 IIl CLR CLR CLR 29.26%29.26%N N N Y Relief Request will be filed for the limitation. N Y Relief Request will be filed for the limitation. N N Relief Request 04-ON-01 5 was filed to allow us to exempt the examination for this item during the fourth interval.N N Relief Request 04-ON-015 was filed to allow us to exempt the examination for this item during the fourth interval.IIl 11/02/2005 I iiU~i=UUD 11/02/2005 11/02/2005 11/02/2005 11/02/2005 11/02/2005 11/02/2005 11/02/2005 11/02/2005 11/02/2005 11/02/2005 10/29/2005 10/29/2005 10/29/2005 10/29/2005 10/29/2005 10/29/2005 10/29/2005 10/29/2005 11/02/2005 11/02/2005 11/02/2005 11/02/2005 CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR N N N N N N N N N N N N N N N N N N N N N N N N V i EOC 21 Plant: Oconee 2 ITEM NUMBER B06.030.005 B06.030.006 B06.030.007 B06.030.008 B06.030.009 B06.030.010 B06.030.011 B06.030.012 B06.030.013 B06.030.014 B06.030.015 B06.030.016 B06.030.017 B06.030.018 B06.030.019 B06.030.020 B06.050.001 B07.020.001 B07.030.001 B07.030.002 B07.050.001 B07.070.003 B09.011.001 B09.011.001A B09.011.030 RO901 1 _00A 809.011.203 B09.011.203A B09.011.208 809.011.208A B09.011.209 B09.011.209A 809.021.004 B09.021.010 B09.021.123 ID NUMBER 2-RPV-25-204-05 2-RPV-25-204-06 2-RPV-25-204-07 2-RPV-25-204-08 2-RPV-25-204-09 2-RPV-25-204-10 2-RPV-25-204-11 2-RPV-25-204-12 2-RPV-25-204-13 2-RPV-25-204-14 2-RPV-25-204-15 2-RPV-25-204-16 2-RPV-25-204-17 2-RPV-25-204-18 2-RPV-25-204-19 2-RPV-25-204-20 2-RPV-WASH-BUSH 2-PZR-UHB-STUDS 2-SGA-UMW-STUDS 2-SGA-LMW-STUDS 2-PZR-RC4-STUDS 2-53A-CF13-STUDS 2-PSL-8 2-PSL-8 2-PIB2-4 2-PIR2-4 2LP-189-1 2LP-1 89-1 2-53A-8-48 2-53A-8-48 2-53A-8-50 2-53A-8-50 2-PDA1-11 2-PIB1-11 2-51A-147-17 SYSTEM 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 53A 50 50 50 50 53A 53A 53A 53A 53A 53A 50 50 51A INSP DA 11/02/2C 11/02/2(11/02/2(11/02/2(11/02/2(11/02/2(11/02/2(11/02/2(10/29/2(1 0/29/2(10/29/21 10/29/21 10/29/21 10/29/21 10/29/21 10/29/21 11/02/21 DUKE ENERG'- )RPORATION QUALITY ASSURANCE TECHNICAL SERVICES In-Service Inspection Database Management System Oconee 2 Inservice Inspection Listing Interval 4 Outage 1 TE INSP STATUS INSP LIMITED GEO REF RFR)05 CLR --- N N)05 CLR --- N N 005 CLR --- N N 005 CLR --- N N 005 CLR --- N N 005 CLR --- N N 005 CLR --- N N 005 CLR --- N N 005 CLR --- N N 005 CLR --- N N 005 CLR --- N N 05 CLR --- N N D05 CLR --- N N 05 CLR --- N N D05 CLR --- N N D05 CLR --- N N 005 CLR --- N N Run D Page 2 01/16/2006 COMMENTS Washers and bushings for stud holes 1 thru 12 were inspected on 11-02-2005 by LP. Washers and bushings for stud holes 13 thru 20 were inspected on 10-29-2005 by JH.10/25/2005 10/30/2005 10/30/2005 10/28/2005 10/28/2005 10/31/2005 10/30/2005 10/27/2005 10/27/2005 11/04/2005 11/03/2005 11/03/2005 11/03/2005 11/03/2005 11/03/2005 10/26/2005 10/29/2005 10/30/2005 CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR---...------92.30%---...------N N N N N N N N N N N N N N N N N N V DUKE ENERW' )RPORATION QUALITY ASSURANCE TECHNICAL SERVICES In-Service Inspection Database Management System Oconee 2 Inservice Inspection Listing Interval 4 Outage 1 f EOC 21 Plant: Oconee 2 Run D Page 3 01/1612006 ITEM NUMBER B09.021.134 B09.021.135 B09.021.136 B09.021.201 B09.032.004 B09.032.201 B09.040.002 B09.040.007 B10.020.001 B10.020.031 B13.010.001 B14.010.003 B14.010.006 B14.010.009 B14.010.012 C02.031.001 C02.031.002 C03.010.003 C03.020.001 C03.020.013 C03.020.021 C03.020.045 C03.020.053 C03.020.054 C05.011.001 C05.011.001A C05.011.002 G05.011.002A C05.011.003 C05.011.003A C05.021.001 C05.021 .001A C05.021.002 C05.021.002A C05.021.006 ID NUMBER 2-51 A-35-43 2-51A-35-55 2-51 A-35-56 2LP-151-1 2-PDB1-12 2LP-151-21 2RC-271-13A 2-50-7-124 2-50-0-1481A-H3 2-53A-0-1479A-H8B 2-RPV-INT-SURFACE 2-RPV-CRD-63WH9 2-RPV-CRD-63W60 2-RPV-CRD-63 2-RPV-CRD-63W61 2-LPCB-INLET 2-LPCB-OUTLET 2-RCSR-COOLER-A 2-01A-0-1441-Hi 2-03A-1439A-RL-0901 2-14B-0-1479A-H1-1E 2-53B-2-0-436E-H1-0 2-54A-3-0-1444-R3 2-54A-3-0-1444-Hi 2LP-148-16 2LP-148-16 2LP-148-17 2LP-148-17 2LP-148-18 2LP-1 48-18 2-RCP-FTR2A-SH-1 2-RCP-FTR2A-SH-1 2-RCP-FTR2A-SH-2 2-RCP-FTR2A-SH-2 2-51A-129-9 SYSTEM 51A 51A 51A 53A 50 53A 50 50 50 53A 50 50 50 50 50 01A 03A 14B 53B 54A 54A 53A 53A 53A 53A 53A 53A 51A s1A 51A s1A 51A INSP DATE 10/30/2005 10/30/2005 10/30/2005 11/03/2005 10/27/2005 11/03/2005 11/03/2005 10/26/2005 10/30/2005 11/04/2005 10/30/2005 10/31/2005 10/31/2005 10/31/2005 10/31/2005 08/23/2005 08/23/2005 11/07/2005 11/05/2005 08/15/2005 11/09/2005 08/16/2005 08/18/2005 08/17/2005 11/04/2005 11/03/2005 08/17/2005 08/17/2nn0s 08/17/2005 08/17/2005 10/29/2005 11/04/2005 10/29/2005 11/04/2005 08/16/2005 INSP STATUS CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR C:l R CLR CLR REC INSP LIMITED GEO REF RFR COMMENTS N N N N N N N N N N N N N N N N N N N N N N N N y N N N N N N------------------------72.40%---...------------Relief Request will be filed for the limitation. All indication sizes noted are < 12.5 surface flaw a/t % per appendix A, Figure B of NDE 12. Acceptable per IWB-3514.3, Table IWB-3514-2. CLR CLR CLR CLR N N N N N N N N EOC 21 Plant: Oconee 2 ITEM NUMBER C05.021.006A C05.021.024 C05.021.024A C05.021.025 C05.021.025A C05.021.026 C05.021.026A C05.021.027 C05.021.027A C05.021.028 C05.021.028A C05.021.073 005.021.073A C05.021.074 C05.021.074A C05.021.075 C05.021.075A C05.021.076 C05.021.076A C05.021.081 C05.021.081A C05.021.087 C05.021.087A C05.021.093 C05.021.093A C05.021.099 C05.021.099A G05.030.001 C05.030.007 C05.030.008 C05.030.009 C05.041.001 C05.051.007 C05.051.007A C05.051.008 C05.051.008A ID NUMBER 2-51 A- 129-9 2-51A-17-100A 2-51A-17-100A 2-51 A-17-101 2-51 A-1 7-101 2-51A-17-111 2-51A-17-111 2HP-227-3 2HP-227-3 2HP-227-7 2HP-227-7 2-51 A-28-67 2-51 A-28-67 2-51 A-28-69 2-51 A-28-69 2-51 A-33-1 0 2-51 A-33-1 0 2-51 A-33-13 2-51 A-33-13 2-51 A-27-3 2-51 A-27-3 2-51 A-27-21 2-51 A-27-21 2-51 A-28-30 2-51 A-28-30 2HP-212-24 2HP-212-24 2-61 B-1 8-48 2LP-98-10 2LP-97-13 2HP-451 -44 2LP-96-13 2MS-124-69V 2MS-124-69V 2MS-124-72V 2MS-124-72V SYSTEM 51A 51 A 51A 51 A 51A 51A 51A 51A 51A 51A 51 A 51A 51A 51 A 51A 51A 51A 51A 51A 51A 51 A 51A 51A 51A 51A 51A 51A 51 B 53B 53B 51A 53B 01A 01A 01A 01A In-S INSP DATE 08/15/2005 08/22/2005 08/19/2005 08/22/2005 08/19/2005 08/22/2005 08/19/2005 08/22/2005 08/19/2005 08/22/2005 08/19/2005 08/16/2005 08/15/2005 08/16/2005 08/15/2005 11/04/2005 11/03/2005 11/04/2005 11/03/2005 08/18/2005 08/18/2005 08/18/2005 08/18/2005 11/06/2005 11/04/2005 11/04/2005 11/04/2005 1 1 /0/20o 08/23/2005 08/23/2005 08/19/2005 08/23/2005 11/01/2005 11/01/2005 11/01/2005 11/01/2005 DUKE ENERG> )RPORATION QUALITY ASSURANCE TECHNICAL SERVICES ervice Inspection Database Management System Oconee 2 Inservice Inspection Listing Interval 4 Outage 1 INSP STATUS INSP LIMITED GEO REF RFR Run D Page 4 01/16/2006 COMMENTS CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR Ci R CLR CLR CLR CLR CLR CLR CLR CLR 37.50%37.50%37.50%79.15%N N N N N Y N Y N Y N Y N N N N N N N N N N N N N N N N N N N N N N N N Relief Request will be filed for the limitation. Relief Request will be filed for the limitation. Relief Request will be filed for the limitation. Relief Request will be filed for the limitation. DUKE ENERGV )RPORATION QUALITY ASSURANCE TECHNICAL SERVICES In-Service Inspection Database Management System r4 EOC 21 Plant: Oconee 2 Oconee 2 Inservice Inspection Listing Interval 4 Outage 1 INSP STATUS INSP LIMITED GEO REF Run D Page 5 01/16/2006 ITEM NUMBER C05.051.026 C05.051.026A C05.051.027 C05.051.027A C05.051.028 C05.051.028A C05.051.029 C05.051.029A C05.051.030 C05.051.030A D01.020.013 D01.020.014 ID NUMBER 2-144B-48-109 2-144B-48-109 2-14B-48-111 2-14B-48-1 11 2-14B-48-112 2-148-48-112 2-14B-48-3 2-1413-48-3 2-148-48-4 2-14B-48-4 2-03A-1-0-1439B-H12 2-03A-1 1439B-H31 SYSTEM 14B 14B 14B 14B 14B 14B 14B 14B 14B 14B 03A 03A INSP DATE 08/16/2005 08/15/2005 08/16/2005 08/15/2005 08/16/2005 08/15/2005 08/16/2005 08/15/2005 08/16/2005 08/15/2005 08/18/2005 08/30/2005 RFR COMMENTS CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR CLR REC N N N N N N N N N N N N N N N N N N N N N N N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.D01.020.031 D01.020.051 D01.020.061 F01.010.015 F01.010.016 F01 .011.032 F01.012.002 F01.012.032 F01.020.002 F01.020.014 2-07A-6-0-1400A-H56 0-13-447A-H7000 2-14B-0-1436A-H28 2-51 A-0-1479A-H9B 2-51 A-0-1479A-H4A 2-53A-0-1481 A-H28C 2-50-0-1481 A-H3 2-53A-0-1479A-H8B 2-01 A-0-1401 B-H21 2-03A-1439A-RL-0901 07A 13 14B 51A 08/22/2005 09/06/2005 08/10/2005 10/28/2005 CLR CLR CLR REC N N N N N N N N N N 51A 11/01/2005 53A 10/28/2005 CLR REC N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.50 53A 01A 03A 11/15/2005 11/01/2005 10/26/2005 08/16/2005 CLR CLR CLR REC N N N N N N N N F01.020.049 F01.020.054 F01.020.071 F01.020.076 2-51 A-3-0-1439A-H77 2-51 A-435C-DE008 2-53B-2-0-436E-H1 10 2-53B-0-435B-DE016 51A 51A 53B 53B 08/18/2005 08/10/2005 08/10/2005 08/10/2005 CLR CLR CLR REC N N N N N N N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order # 98358513 was written to correct problems.N N The discrepancies that were found were reviewed by civil F01.020.091 2-54A-435B-DE1 5 54A 08/10/2005 REC DUKE ENERG)=- !RPORATION QUALITY ASSURANCE TECHNICAL SERVICES In-Service Inspection Database Management System I EOC 21 Plant: Oconee 2 ITEM NUMBER Oconee 2 Inservice Inspection Listing Interval 4 Outage 1 INSP STATUS INSP LIMITED GEO REF Run D Page 6 01/16/2006 ID NUMBER SYSTEM INSP DATE RFR COMMENTS F01.020.097 F01.020.102 F01.021.023 F01.021.028 F01.021.053 F01.021.063 F01.021.073 F01.022.001 F01.022.011 F01.022.043 2-54A-3-0-1444-Hi 2-56-438C-DE008 2-14B-0-1479A-H 1 E 2-144B-0-1 439A-DE1 93 2-51 B-0-436J-DE019 2-53B-5-0-444-R12 2-54A-3-0-1444-R3 2-01 A-0-1441 -Hi 2-03-0-1479A-H2A 2-51 A-3-0-1444A-H75 54A 56 14B 14B 51B 53B 54A 01A 08/16/2005 08/16/2005 11/08/2005 08/18/2005 10/28/2005 08/18/2005 08/16/2005 11/09/2005 CLR CLR CLR CLR CLR CLR CLR REC N N N N N N N N N N N N N N N N engineering and the support was found to be acceptable for service. Work Order # 98358609 was written to correct problems.The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order # 98360872 was written to correct problems.The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order # 98358603 was written to correct problems.03 11/01/2005 CLR 51A 08/16/2005 REC N N N N F01.022.062 F01.030.001 F01.030.012 F01.030.018 F01.030.023 F01.030.041 F01.031.012 F01.031.016 F01.031.022 2-54A-3-0-435B-R1 01 2-01 A-4-0-1400H-DJB1 2-03A-1 1400A-H108 2-03A-1 1400A-H88 2-03A-1401 B-DE009 2-07A-6-0-1400A-H58 2-03A-1 1401 A-SR3 2-03A-1 1400A-H73 2-03A-1 14393B-H-12 54A 01A 03A 03A 03A 07A 03A 03A 03A 08/10/2005 08/22/2005 08/22/2005 08/22/2005 08/22/2005 08/22/2005 08/22/2005 08/22/2005 08/18/2005 CLR CLR CLR CLR CLR CLR CLR CLR REC N N N N N N N N N N N N N N N N N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.F01.031.051 F01.032.011 F01.032.021 F01.032.041 F01.032.051 F01.040.003 0-1 3-447A-H7000 2-03A-1 1439B-H31 2-07A-6-0-1400A-H56 2-1 3-7-0-1400A-H9 2-14B-0-1436A-H28 2-PZR-SKIRT 13 09/06/2005 03A 08/30/2005 07A 08/22/2005 CLR CLR REC N N N N N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order # 98358508 was written to correct problems.N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.13 08/22/2005 REC 14B 08/10/2005 CLR 10/25/2005 CLR N N N N DUKE ENERGY'f RPORATION QUALITY ASSURANCE TECHNICAL SERVICES In-Service Inspection Database Management System Oconee 2 Inservice Inspection Listing Interval 4 Outage I go,-t EOC 21 Plant: Oconee 2 Run D Page 7 01/16/2006 ITEM NUMBER F01.040.005 F01.040.006 F01.040.012 F01.040.024 F01.040.029 H03.001.001 H03.001.002 H03.001.003 H03.001.004 H03.001.005 H03.001.006 H04.001.001 H04.001.001A H04.001.003 H04.001.005 H04.001.005A H04.001.006 H04.001.006A H04.001.007 H04.001.007A H04.001.044 ID NUMBER SYSTEM INSP DATE INSP STATUS INSP LIMITED GEO REF RFR COMMENTS 2-DHRC-A 2-50-RCPM-H6604 2-LPI-PU-A 2-LDFTR-A 2-RB-CC-A 2FDW-225-22B 2-03-18-22C 2-03-18-23A 2-03-18-23G 2-03-18-24 2-03-18-24G 2-03-0-1439B-H62 2-03-0-14391B-H62 2-03-0-1439B-H53 2-03-0-551 -H51 2-03-0-55 1-H51 2-03-0-1401 A-R8 2-03-0-1401 A-R8 2-03-0-551-H50 2-03-0-55 1-H50 2-01A-0-1401 B-H21 08/09/2005 CLR 11/01/2005 REC 08/10/2005 REC 11/07/2005 REC N N N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order # 98360130 was written to correct problems.N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order # 98693574 and 98325040 were written to correct problems.N N The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order # 98360898was written to correct problems.This exam does not count in the outage 1 percentages. 03 03 03 03 03 03 03 03 03 03 03 03 03 03 03 01A 10/28/2005 11/12/2005 11/12/2005 11/12/2005 11/12/2005 11/12/2005 11/12/2005 11/09/2005 11/11/2005 08/16/2005 10/26/2005 11/07/2005 11/01/2005 11/07/2005 10/26/2005 11/07/2005 11/02/2005 CLR CLR CLR CLR CLR CLR CLR REC N Y Y Y Y Y Y N N N N N N N N N Indication

  1. 1 is a geometric reflector due to Backing Ring.Indications
  2. 1 and 2 are geometric reflectors due to backing ring.Indications
  3. 1 and 2 are geometric reflectors due to backing ring.Indications
  4. 1 and 2 are geometric reflectors due to backing ring.Indications
  5. 1 and 2 are geometric reflectors due to backing ring.Indications
  6. 1 and 2 are geometric reflectors due to backing ring.The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order # 98360883 was written to correct problems.CLR CLR CLR CLR CLR CLR CLR CLR CLR N N N N N N N N N N N N N N N N N N I 5.0 Owner's Report for Repair and Replacement Activities As required by the applicable code, records of Class 1 and Class 2 Repair and Replacement work is included on NIS-2 forms in this section.Due to station processing and approval time frames, three categories of repair and replacement documentation exist for: 1) work performed during a prior refueling cycle; 2) work performed during the current refueling cycle; and 3) work completed but documentation not yet reviewed and approved.There were 28 work orders for category 1 repair and replacement documentation for this reporting period. Work Orclers 98540409, 98540880, 98540875, 98540889,98539671,98539673,98532391,98532393,98530942,!98530949, 98516356,98516357,98516899,98516911,98532818,98532820,'98537912, 98537914,98541036,98621223,98648846,98540919,98644159,'98540909, 98540994, 98624546, 98617114, and 98616047 had work completed prior to 6-15-2004 and copies of the NIS-2 forms are included in this report. Twenty-five of the work orders are associated with the Steam Generator Replacements and the NIS-2 forms associated with this work are the first 148 pages that immediately follow this page. Three of the work orders are associated with the Reactor Vessel Head Replacements and the NIS-2 forms associated with this work consist of 17 pages that follow the 148 pages from the steam generator replacement NIS-2 forms. PIP 0-04-05070 and PIP 0-04-04879 were written at the end of the Unit 2 EOC-20 refueling outage to document the late submittal for the NIS-2 forms 1lu ,/ associated with the 28 work orders listed previously in this paragraph.

Category 2 had 59 NIS-2 forms for work orders completed during this reporting period. Copies of the NIS-2 forms are included in this section of the report.There were no items for Category 3 during this reporting period.The individual work request documents and manufacturers' data reports are on file at Oconee Nuclear Station.5.1 Class 1 and 2 Preservice Examinations As required by the applicable code, Preservice Inspection (PSI) Examinations were performed on ISI Class 1 and ISI Class 2 items during this report period.There are two lists for PSI exams that were performed and both lists are located behind the NIS-2 forms in this section. The first list has two pages and is entitled"Steam Generator Preservice Weld Examination". The second list has one page and is entitled "Preservice Examinations of Class 1 & 2 Welds". PSI examination data for items on the two lists previously mentioned are on file in the Oconee Nuclear Station QA Vault.EOC 21 Refueling Outage Report Page 1 of 1 Oconee Unit 2 Revision 0 Section 5 January 16, 2006 fk FORM NiS-2 OWNER'S REPORT. ,REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xi A 1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 1.a Date 09/22/04 Sheet 1 of _33-2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 2a. Unit rF P'2 r-3 r Shared (specify Units j 3a. Work Order # 98540409. 98540880. 98540875. 98540889 3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A 4. Identification of System Reactor Coolant System Class 1 Repair Organization Job #3b. NSM or MM # ON-23086 AS6 WP 22570A. 23040A.22570B, 23040B, 23065A, 23065B 5. (a) Applicable Construction Code ASME III 1989 Edition N/A Addenda, No Addenda 'Code Cases N-20-4. N-4 (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and 74-2. 2142-1. 2143-1 cc and their supports.)

6. Identification of Components Rep ired or Replaced and Replacement Components Column I Column 2 Column.3 Column 4 Column 5 CoI. 6 Column 7 Column 8 National l llASME Code Ba.rd a uOther Year Repaired, Replaced, Stamped (yes Name of Component Name of Manufacturer Serlal Number Number Identification BuIlt or Replacement or no).rRepalred r No Babcock & Wilcox Co. iv Replaced R Yes A Steam Generator Barberton, Ohio 620-0004-55
  1. 1 107 SG 2A 1971 r Replacement Babcock & Wilcox of F Repaired F No Canada, Cambridge, r Replaced Fe Yes B Steam Generator Ontario 006K03 207 SG 2A 2003 P7 Replacement r Repaired r No Babcock & Wilcox Co. Po Replaced Pr Yes C Steam Generator Barberton, Ohio 620-0004-55
  2. 2 108 SG 2B 1971 r Replacement Babcock & Wilcox of r No Canada, Cambridge, r Replaced F Yes D Sam Gencrator OntarIo 006K04 Zu8 SG 2B 2003 Replacement rRepalred r No rReplaced r Yes E rReplacement rRepalred r No r Replaced F Yes F FrReplacement ml Form NIS-2 (Back)Sheet 2 of 33 NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information in items 1 through 6 on this report is included on each" sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced Unit 2 A & B Steam Generators
8. Test Conducted:

r Hydrostatic r Pneumatic 17 Nominal Operating Pressure r Other r Exempt Pressure psig Test Temp OF Pressure psig Test Temp 'IF Pressure psig Test Temp .F 9. Remark. Removed Unit 2 steam generators 2A (620 0014-55 #1) and 2B (620-0004-55

  1. 2) made by B&WV of Barberton.

Ohio and replaced with 2A (006K03) and 2B (006K04) made by B&W Canada of Cambridge. Ontario. Applied Code Case N-416-1.(Applicable Manufacturers Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.Type Code Symbol Stamp NWA Certificate of Authorizationpl. NIA 5 s Expiration Date WA Signed .-7A:/'- Date os/2ZZ- +CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commision issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of C and employed by have inspected the components described In this Owner's Report during the period.to .A2v0e ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions

  1. JC 53. tc, w Ins eoes Signature National Board, State, Providence and Endorsements W , Date _ 42 M
  • t* to F I , M-.* \ ' ?-= -. If-1 Dtj3o A A--I A i ~ ~ Nr ..J' '-. .()/E *-1: I'-T 1971 tong F JN:T '^'-1C 04' l*~A .: .* , s , .*v ., 2* ........_ .

FORM N1 CRICATE HOLDERS' DATA REPORT FOR NUCLEAR VESSELS*As R t red bythe Provisions ofth&eASME Code, Section IAL Dision 1 Pg. I of 6* .iz z: l.asddh.4 cdiebabmcOkIWilcx Canada, 651 ContrionBXeCambMide, Onaido NlR5V3-MantactSme snd ICIm b 4~ 2Monuxcud for1wZWra P.D.Bx 1006, Charlotte, North Caroffna. 2W2;,00 3.iLocation of krsato I..conee2. Seneca, Soat Caroet , _4.Type: Vert HeaXE. K 006KO.3 R- OCSKE01ev..4&EO2F20.103

5. ASME Code. Sedcion Hl, Divion 1: .kbine 1 Lst 41 AIL 4!11~ uslve to be completed orsngle walvessels leckets of lacketeseek otahelsdieatchanoers.

6.Shell SA150BCLSa 90iksl list2AM Ust #2AIL LW t#2 At List#2Alt ListE3 7. Searns UT #3 Ati Ust 13 All. AtL LIst 3 At List #3 ALl. Ud t3Al Lst3 AtL 4 On WIl W1 ti- O' (R' raQ 8. Heads _ _ _ _gal Rnai spec. hNu LocationV Thickness lCorrosion lCrown l vi~oue sof M i l misphadcalRadius lFlat lIaconvexsor I(0b -----I I Iirfemovab boltsused: -Otherfastenling -S. Jacket Oosure: MIr lfDacttb n3agn &a~d baz Lhtc.E bar. po m"1. bun$.04d, Gr Skgdtj,-d 600 bn. pressuretesttemp 70 k-. Pneu.h. r, orcomtined test IrF) CF)Isu*, 1500 (PSrO la Designprssure 2 1150 AtrmaLtemp. ltems 11 and 12 to to completed or tube sectlons 1 11. Tubesheets: SA-S0 Cf. Se Wan flfcocv.s4 I~ -Putfa./137K 2243116 welded I(92(.-sL to pclM TL*nsWslT l ltabc-nd4bAt4i lrkm~l POclUORkL l Rractiioii 12.Tioes S-i-163 UNS N06690 % 0.03 15631 shight O"LaSML .w4 M01 11MwICcb&P*) (.4 MIe takakftotnI to be completed foeror dwrntere ocketed vessels o channels of hat exhangera 1S _, _Shelf: 14.Seams 15. Heads----kQI-- --Sngle Yes fuil 1&OPV4 A^siol PTIO-11 e(ffn --rl -S low* (HP r-SAS406 aC3e 90ksi -_ -Ua WEr SWl nQ (p r saMgtnj t(01n Pa We pa.lSthl Location (a) Ton, bottom, ends b) Chlanel -otng Channel -bottom_(c1 Roating:4::T Thicness Crown R~adiuss_% _6r.I Knudde Radius EllRaio-1:1.- _1:1_ I _Coxcal Apex I Angle I _I -Hemispherical Radius_ 59-17132 6 59-17W32=Flat Diameter'.7..w Side ID Pressure.(aonvsx or concv)concave A I 11 removabe, olts used Other fastening-(dawr cr aUch shost)(frL spc, no.. sze qirtivt)Ijuen 2500 6550 \inipressure testte;rrp. 70 Pneu., bwa., or comb. Test pressure* 1'UPostv eld heattrealed. 2List othr inernl o external prassure with coincident temperature hen appcable.* *Supplcmentat inlomwtoin toe frm oflists. sktces, ordrevmingsmaybe usedprovided i1) size Isg Xl, (2) inforrnation i items t through 4ontiDatI*Sch sheet, (3) each sheet is nurnbered and the rnuber of sheets Is recorded on the top of his form. A<%3125 A................... __ 4?'Ile So-F3 3 FORM N.1(back Pg. 2 of I.. .I .1 .... _ .:1. .6 ?Cevitcate mq hi srw No. talN3 17 LmvwI.e ln~anMj-9n M ..A n,.e m nan.R* .---. -W---. al US"NKl: WUS* V. I+/-... ,-TI --_Hrot Reinfoczement _ nlet. ou__at _ _et Quadtvi Dia. or size Tyne attached Matlt Thickness _ Material Locaion_ _ _ I _ I _ __18.Support Skit SeeList l5 Lugs SesListil5 Legs _ -Other -Attaed SeeListl5 jduG) l \r am rw ,-19. Remate Prevbus N-2 Forms forthe PmaryHeads (Manufactred byJapai Steel Wok. Mur PlanL National Bcard Numbrr 2 nd4Bd.CERTIFICATION OF DESIGN Design specilication certified by See List d6 P.E. Stats See List 46 Fleg. No. See List #6 Provnce Design reporrcetirrfedby J. T. Bod P.E.Sa Ont. Reg. No. 04801502 CERTIFICATE OF SHOP COMPLIANCE We cerSfyF that the stalements made in this report are correct and that this nudearvessil conforms t hIe rules for conshtrotion'of i d2 a Sedion lii Dision 1.N Cere or Authlzation No. NMT9 Exphrs sJane 2 2004 Date October2Bx,2003 Name Babcock &Wi=oxCanada Signed .' S .i&SHT IN Certificate HokoeWi; ___ (authotzed re sesntamve) ULt TIFICATE Ur SHI)P INSPElTIUN 1, tie undersigned, holding a valid commission Issued by the National oard of Eloler and Pressure Vessel Inspectors and the State or Prviknx of Ontarb and employed by TechnIcaStandards nd SfatyAutorit of Ontarm have hspectd the cwnponent desaibed in this Dats Report on ., and sta that to the Best of my imewtedge aid beiel, the Certifcate Holder has constructed this component in accordance with ihe ASME CodKSedidin 1, DWK=on 1.By signing tbis cartificate, neither ft inspector nor his employer makesxny warranly, expressed or knphd, concerning the component desoibed In 1his DEta Report. Rfffthensre. neither the nspectornorhis empbyerthafbe labbe ieany maninerforppenalr'rprep e ty danageorloss;oany ldndarising fromoronnecledlwihthisInspedcon Date Oct 28, 03 Signed _ _ _ Commissionts CERTIFICATE OF FIELD ASSEMBLY COMPUANCE.-Wecartrf thattiie statements on tWis report are correct and hatitie field assembly constnucton o all paiis of this nuclear vessel confuemso tthe mles oh c1struction of The ASMU Code, Sedion IlD Division 1.N Certificate of Authorization No. _ Expires Bats Name Signed IN Ceffi&At. H.A 1-0-i-A C ERTFICATE OF FIELD ASSEMBLY INSPECTiON

1. the undersigned, holding a valid cornmission issued by th National Board of Boiler and Pressure Vessel Inspectors end the State or Provine of VW and epyed by of he compared the statements in this Data Report wt the desribed cmonient and state that pat retenred to as data hems___ ___ __ __ _ __ ___ roti ncluded in he certificate of shop Inspection, havu been hsperct by me on inccr ______hto

_ _CdeSctonMlDviio 1 and that to the best of my 1nowledge and belef the Certificate Holder has constructed and asswmbled this corwponent in accorance with the AnfdE Code, Section ll. i, siion 1.By signing this cerficale, neer the inspector nor his employer makes any wananty, expnrssed or implied, conceming ths component described in this Data Report Furthermore, neither tie inspector nor his employer shal be liable in any rnauner for any personal iNjury or property damage or loss ot any kind arising from or cornected wMh his Insecto I Data Stoned Commissbnsq Date Sinne.......-n"t &^> 633 Attachment to FORM N-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR VESSELS As Required by the Provisions of the ASME Code, Section 1i Division 1 PO. 3 o0 6 t. pahcaxod and cartiod by ,4. -2MMM. rted for D 3. Lacotion of InsWW=aio Babcock & Wilcox Canada, 581 Coronation Botilevad, Cambridge, Onarb N1 R 5V3--uke Power Company, P.O. Box 1006, North C arolina, 28201-1006 _"MoAmmalftdaw Oconee 2, Seneca, South Carolina 4.Type: Vertical ramo VMv Heat Exchanger 0081(03 via" SW auss OOE06I Rev. 4&-00KE002 Rev. I 207 t/MR01wmlo4 2003 Lf ermbr~LUst #1 N-20-4 N-474-2 2142-1 2143-1 Mst#2 j~~ ~ ~ -_. -__. 5 .,__ __Min. Length (per Nominal Design Inner section Lengthl Thickness Thickness Diameter thickness) Overall Shell can below upper T/S 5yan" 5" 137%W 523/4 131 13/16" (thick shell, adjacent to T/S, taper 3t/.' 3' 1371W 79 1/16" to thin shell)Thin Shell to Thick to Thin 3Y 3" 137W/ 19Y4 159%8/" 5W/. 5 1377 112Ys*_ 3W 3' 1377/. 27%a Thin Shell 3" 3' 1377h" -173%/'Shell Can Above Lower T/S 3V 8' 3s 13714 106 7/16' 159 3/16'(thin shell taper to thick shell, 5'1/ 51 37'/an 52Y2W adjacent to T/S) .!( ...^=UwCent t rum M1 GNtIRAT HOLDU " DATA REPORT FOR NUCLEAR ESS 7 As Required by the ProMVstons of the ASME Code, Section I, DivisIon 1 -g.f 1. Mhnufcdutud and caried by Babcock & filcox Canada, 581 Coronation Boulevard, Canbridg ( 2Manutaursd fr _ Duke Power Company, P.O. Box 1006, North Carorina, 28201-1006

3. Locaon of Instanaon Oconee 2, Seneca, South Carormna e.Ontario N1R5 V3 :-_ _ __4.TType: vertical_ -WV )/e 006KE001 Rev. 4 &Heat Exchanger 006K,3 I " -006KE002 Rev. 1 ouka"4M0s4 LHani"on (GRN cm, Ps 104 2D7 200310 ., ONZM.) oJwe'-List #3 Seam Longitudinal Joint HI RT eff (°h) Girth Joint HT RT;Type Type Tubesheet N/A N/A NIA N/A (Forging)

Double Yes Full Shell Can #1 None Yes Full 100 Double Yes Full Shell Can #2 None Yes Full 100-__ Double Yes Full Shell Can #3 None Yes Full 100_ Double Yes Full Shell Can #4 l None Yes' Full 100 Tubesheet N/A NtA N/A N/A Double Yes Full (Forging)4--_f. r n w Hfl elwfflf r s ,j._ S .3 AUncnment W MUfiM WI CrAicmATe lQoL5ERs DATA REPORT FOR NUCLEAR VESSELS As Requlred by the P1ovisions of the ASME Code, Section Al, DMslIon 1 Pg. 5o1 1. an anid coad by Babcock & Wilcox Canada, 581 CoronatIon Bouuard. Car mbndae, Ontario NiR SV3 Hel t. "aaeMG1C4IMAwi 14K 2.Manufachradfor Duke Power Company, P.O. Box 1006, North Carolina, 28201-1006 -3. Locaton of Inslafladon Oconee 2. Seneca, South Carolina*EumnsaladaCPsfMS0

4. Towe: Vertical (tawsI" Heat Exchanoer 00610)3 K WtP.& js0. M 4 Ce-ba_OO6KEDO1 Rev. 4 &-006KE002 Rev. I 207 2003 Eha- Br.m40 Wi-u)(CM) (migI o4 List 44= : = = _ _ _ _ _ ._ -_ _ _Pwpos etoullek MY. go) Type HOwAftwbed Mabw Oh) Rehlorcement Locaton dMu ) O Dh er Thiktess jltrlal fq No des Wet 1 38' Irtegrl SA-oa CL 3a 3' WA. UpperCharL Head Prbury Nlesi1U 2 28' 5. Welded SA-O SCL 3a 3%' NIA LowerChna Head prnyrMMMay 2 16B I Integral SA-a CL Sa Ir SA46OCL3a Chan.Heads PnmaryManwayCwer 2 28w -BOlW SA533 Typ. B CL 1 SW NIA Chan Heads Ptrwylandhe 1 6' I Inte#al SA.5M Cl 3a 35S WA Upper Cran.__.______

How Pftwam8hoteC0ar 1 12% -BMatd SA.533Typ. 8 CL 2W WA upperaC Hea SeUondaiyIaKhdoles S 63 I Intgral SA-408CL3a _ NA Shea HndhrdeCoves 5 12Y' -Bolted SA-533Typ. B CL 1 2 WA Shel lonpelin Poft 30 3T I inteil SA-508 CLM3a W A She a pvecow PonrCwers 30 6Y' -Btd SA 533Typ. B CL1 1. WA Swel FeeWnWNozsbfdby 32 4 -Wesdedtold S41l82Gr.F22 OS32' N/A Shot exeal hieader_AwedalFaterNozzes 6 4' -WeedIBoled SA-182 Gr. F22 OL602 WA Shea led by e al header Seylaiway 2 16' _ Integral GASS CL 3a NIA Shea SemndaryManwayCower 2 25Y 4 -SBoled SA633 Typ. B CL 1 3' WA Sheln SteamNole 2 22265! F WeOded SA40B CL3a SW SA4-08 CL 3a Shel lrsinentNozades 7 1v F. WeldW SFAU5E70t8A1 0.4t WA She!ItsltumernNows 12 I F Welded SFASSE70IBAI 0.415' WA She!MFW spednPFugs 8 V: F Welded SA-105 ox SA-105 Shel Do wnTean Sensor 3

  • NPT _ Welded 5479Type 316L 0565" WA She!-_ -._ _I-ra -no protuding shell penetration F = fuh penetration weld I = Integrally forged P=partial penetration weld..r It iVAn nwsv~ac .ev n an.

.Auacnment M FORM r1 CERFICATE HOLOERS' DATA REPORT FOR NUCLEAR VESSELS As Required by the Provisions of fe ASME Code, Section Di1, Division 1 pg. cd 6 1. Manctued and cered by Babcock &WIlcox Canada, 581 Corona6on Boulevard, Cambddg I ~ Z.Manuiaured for Duke Power Company, P.O. Box 1006, North fCFamna, 28201-1006 3.Locatbn d staltaon Oconee 2, Seneca, South Carolina e,Ontario NlR6V3_4.Type: Verucal 'Heat Exchanger-p9LOrVW4 kpmkedMar4 006KEOO1 Rev. 4 &006(03 -006KE002 Rev. I WLaHQUWewt(M C- pt!4 207 2003 -t(Wl~j.N0.1 01, W LIst#5 Description Skdrt Lugs Legs Attached (ihere &_yes or no) (qty.) (qty.) howv tower Shroud Lugs No 12 _ shefelded Upper Shroud Lug Yes -_ shealugral OriflceRing Lug Yes _ -sheflntgra Lower Prknary Head Base Suport Yes _ _ dcarnel._ headuifegral _ .~ =. __list #6 Name State Rec No.M. C. Keck N.C. 18387 1 J. C. Herrin N.C. 14504 rl-**^-rzro e.~v -.. I'R -to o33 ,< -19 FORM N-2 CERTIFICATE HOLDERS'-DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES' As Required by the Provisions of the ASME Code. Section 1II Not to Exceed One Day's Production Pg. I of 2 Manufactured and certified b JL~fiTapzn Steel Workts, Ltd., luroran Plant/4-C atsui-mac, a, iroranUok.4X.do,oS O-B50; Japaz.(name and eSs at NPT CardV41ara M I Manufactured for Babcock CWilcox, 581 Coronation Blvd., Cambridge, Ontario, h R 3V3, Canada Ii ,ine and aarm o apurchasedf I. Location of installarioalonee ucleer Power Plant Unit 1, 2 .& 3 Oconee, Sonth Carolina Inaa and addreSs)I. Typte 148361W, 11ev. 2 SA-50, Cl. 3& Hii 90kst 2_ 001 Wawing Ao.) trnits. tsoa no.1 tsurangith. -i.CNR (Yaear GOAMzt i. ASME Code, Section I11. Division 1: 1989 U o addenda __Itodilon)l laddnas dare) duast UCode Cose no.1 i Fabricated in accor4ance with Const Spec. IDiv. 2 only) Revision -Date _ -'. Remarks: k dtrostatic test is not performed in The Ja aa Steel Works, Ltd.Cladding thickness is Min. 0.20" from base metal.Cladding caterials are SPA-5.4, AIS C1. E309L-16 -+ 238L-16 an ShA-5.9 ER09Qt + 08LAT..L Nom. thiciness (in.) 6-3/8' Min. design thicknes (in.) 16-4" Dia.ID(frt&inj 9-11-75" J. When appilcable, Certificate Holders' Data Reports are attached for each hem of this report Length overall (ft & in.) 7-0.87" National Part or Appurtenance / Board N., Serial Number In Numerical Order (2)_3)___ _(5)(81___________________ 8T ) ___ _ _ _ _ _ __ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _(11)(12) -_(13) _ _ _ _ _ __ ____ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _(14)_(1 5) __ _(16), (17)(18) ___ _ _ ___ _ _ _ ____ __ _ _ _ _ _ _ _ _ _ _ _ _1 8) __(1 9)(20) __ _ _ _ _(21) ___ _ _ __(22)(231 _ I _(24) _ -(251 __ _National Part ar Appurtenance Board No.Serial Number in Numerical Order 12B)(29)(30)(31)(32)(34)(35) 1 436)(37) _(38)1411 (45) inQ ,1 (49)i50z z Design pressure N/A psi. Temp. N/A F. Hydro. test pressure i PZ /A _ at temp. *F Iwitin *801icaoial emerl information In the form of lists. skctches. or drawings may be used provided 1) site is ag, x 11, 12) Information in items 2 and 3 on this Data Report is~Wd on each sheet, 13) each sheet Is numbered and the number of sheets is recordea at the top of this lorm.is) This form (8E0040) may be obteined from the Order Dept.. ASME. 22 Law Drive, Box 2300. Fairfield. NJ 07007.2300.

  • P.O. No.: C!3313-834.

JSW Job No..: FN9-4305 Heat No. JSW PC. No. : 3 EOOOLO JQA-01-190 E FORM N-Z{Mack-Pg 2 of 2 ( Certificate Holder's Serial Nos. 105 throu;h CERTIRCATiON OF DESIGN Design specifications certified by P.E. State N/A Reg. no. N_ A twhen 40%91l~abl Design report' certified by { in ?.E. State N/A Reg. no. H/A.1In 8901:0ble CERTIFICATIE OF COMPUANCE We certify that the statements made in this report are correct and that this {these _ Part co-nforms to the rules of construction of the ASME Code. Section 11. Division 1.NPT Certificate of Authorization No. N-2725 Expires June 29, 2004 _The Japan Steel Works, Ltd .Date Auc. 30, 20013 Name Huroun Plant Signed NHPT Wdfwi hSg nedr" wata_~q .T___ .a CERTIFICATEl OF INSPECTION

1. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ILINOIS and employed by K*S'B.I. & I. Co.of _EMRWD. CT. have inspected these Items described in this Data Report on rLL t e
  • l .and state that to the best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances irnccordance with the ASME Code, Section 111, Division 1. Each part listed has been authorized for stamping on the date shown above.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described n this Data Report. Furthermoro, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage; _er loss of any kind arising from or connected with this inspection.

Da .30 l sL. Commissions bi lOS, N, 3 A C --.A h o ad Nudear InSne tared IN ze e& (!i .L n dr smenm l and A mra or Orcv. and n o.l AO_Mfla n (aC &frh //win~qe-i ctki/Sr~n /2 6 C*s / -e ,_'~ APPROVED O EIWC!NCONMUG INSPE6TIONI NU' 6 201 J1 / -? -itl'p 35 ,1OA -OI- 178 r-FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES-As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production Pg. 1 of 2 1. Manufactured and certified by kvhXJapan Steel Works, Ltd., Nuroran Pie/4-C acsa-nachircror.H0]dtLdcO52.'85O5 Japan Inama mnc swanet of XPT Camiksaa Halder)2. Manufactured for Babcock ;lcox, 581 Corouation Blvd., Cambridge, Ontarlo, NiR 5V3, Canada/'mams aino agarns GI 9cmhasrll 3 Location of installatio ,,onee Nuclear Power Plant UnLt 1, 2 & 3 Oconee, South Carolina blae naridadteS

4. Type N148344N, Rev. 1 SA-508, C1 3a jft. 9Pksi _ 2001 icrwing no.) ImarlI swez noJ Iansise uang) (CAN) llatr ouit 5: ASMIE Code. Section Ill. Division 1: 1989 No deda 1_ _ _leOn) teodeng oaVa Wantti ICoan ho.)6. Fabricated in accordance with Const. Spec. (Div. 2 only) R Revision Date _isa.)7. Remarks:
  • Hydrostatic test is not performed in The Japan Steel Works, Ltd.Cladding thickness is min. O.20"frocs base mretal.Cladding materials are SFA-5.4, AWS CU. E30!3L-16

+ E308L-16 and SFA-5.9 ER309L + ER308L.8. Nom. thickness (in.) 6-3/8" Min. design thickness (in.) 6-14 Dia. lD (ft & in) 9'-11-75 Length overall (ft & in.)9. When applicable, Certificate Holders' Da:a Reports are attached for each item of this report National Part or Appurtenance Board No, Serial Number in hNum, ericLr4d (1) 1054 r 32 (2)(3)(4)(5)(6)(17)(14)(15)(15)(20)(21)(22)(23)I 24)(25)National Pan or Appurtenance Board No.Serial Number in Nu-nerical Order (26)(27)(28)(29)(30)(31)(321 -(33) _(34)(35)(36)137) _(381 t lM Itu (39)(42)(43)(144)* §A'P C, (45)(46)(47) t (48) _49)1!50)10. Design pressure -N/A psi. Temp. N/A IF. Hydro. test pressure A Z e et temo. IF 4 i4,rolementat information in the form of lists. sketches, or drawings may be used Provided (1) size Is 8i4 x 1;. (21 inlormation in items 2 and 3 on this Data Report is dad on easn sheet, (3) each sheet is numbered and the number of sheots is reccrded at the top of this forn..W This form tEr0040i may be obtained from the Order Dept.. ASME. 2;! Law Dive. Box 2300. Fairfieid. NJ 07007.2300. 11IIDllI1ID111III1

  • P.O. No. : C13313634 JSW Job No. : FN9-4304 I11lili1l1la'U 111il 1 Heat No. : f0D425-1-1 JSW PC. No. : 3 E00040 F.JQA -l 17& -17 NN FORM N-2 (Back -Pg 2 of .. IJ Cenificate Holder's Serial Nos 1054 through CERTIFICATION OF DESIGN Design specifications certified by / P.E. State N/M Rea. no. N/A iwhent spoEicabie Design report* certified by N/A P.E. State N/A Reg. no. f/A twnen apSpfcabt CERTIFICATE OF COMPLIANCE Wecenrtfy that the statements made in this report are correct and that this (these) Part conforms to the rules of construction of the ASME Code, Section Ill, Division 1.NPT Cenificate of Authorization No. -2725 Expires June 29, 2004 The Japan Steel Works, Itd.Oats July 24, 2W Name Muroran Ple..t Signed Tafra.OCPT CeNlrtcae Haidtari (U&4hftd ,ePM1ftta "Iv rrcetirwtodttl

\ J. Taira.CERTIFICATE OF INSPECTION

1. the undersigned, holding a valid commission issued by the National Bioard of Boiler and Pressure Vessel Inspectors and die State or Province Of ILLINOIS'

_and employed by LS.B.I. & I. Co.of 8RAF0RD. CT. have inspected these items described in this Data Report or .y 0 and state that :o the best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in cordance with the ASME Code, Section Ill. Division 1. Each part listed has been authorized for stamping on the date shown above.By signing this certificate, neither the inspector nor hic employer makes amny warrenty; expressed or implied, conceming the equipment described n this Data Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection, DaSgnd A S Commissions NB10104, N, B, A iAvhrina Nudciev kswecd (Nati. CL (hid. exoruaemntrs) Sn U UM OP.tJr Ond nol/fie7md<0 Vie1r .1too,/o hS Pcr,/ cuiA6 X4 y/ *e 9h Y/0 B/StVer S D > /@f 9/o 3~ j INCOMING INSF'ECTION SEP 20 2OC1 I APPROVED I f /JJ Z)p95 -.l. .'.:.' ' X'.... ..3; .. -~>>S.\z.z; /L/ q 33 FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code, Section Xl.owr Duke Power Company Date October 29, 2003-PO Box 1006, Charlotte, NC, 28201-1006 Oconee 2 2.1 z.. ".Plant.._...Name Seneca, South Carolina Sheet 1 of 1 Unit 006K03 207A RepakfuWacameat ognizuuaon P.. N4. Jcb Nn. or-Type Code Symbol Stamp N Authorizaton No. N-2784 cxp -ua uaw.1312In Ad**"U 3. Work Performed by Babcock- & Wilcox Canada 581 Coronation Blvd.. CaMb2idge. Ont N1 5V3 U-..Pab SUU66 WGUM j .. .4. Identfication of System 707 S. (a) Applicable Construction Coda ASME Sec III 1989 \ n No /A Addnd,_ Code Case (b)Applicabl Editon ofSecdon XI lizedforRepalrReplacormntAntivity 1998 -2000 Addenda yenr (c) Applicable Section Xl Coda Caes -s 6. Idmnffatlon at Components .I .ASME-Non or d, Coda Name of Nane of Manufacturar Board Year Ramoved, or Stmrnped c=inpomit Manufctebr Serial No. NILo. a9.- Idoticatian uilt Inrsuted Yoes or me)exanger B&W Canada 006K03 207 N/A 2003 See Bel.ow Yes 7 _ _ I _ ii=-7. DescrpoonofWork One prim. inlet nozzle, two Drim. oi'tlAt nnT7,wr -t1Aq e1-Ar4A ? -94cal-machined. MWHT not performed. Two steam outlet nozzles final machined.LTeuts Conducted Hydrostatic a Pneumatic 0 Nominal Operating Pressure. 0 Exempt 0 Other 0 Pressure psl Test Temp. If NOT Supplemental sheets In form of list, sketches, or drawings may he used, provided (1) size is 8%. In. x 11 In., (2) infornmtion In Items I through 6 on this report Is included on each sheet, and 131 each sheet Is numbered and number of sheets is recorded at the top of this form.(/311 This form (E00G30) may be obtuined from the Order Dept; ASME ;o Law Drive, Box 2330, Fair'ild, NJ 07007-2300. E00030 15- !e4 ?3 FORM NIIS-2 (Back)S. Remarks Applicable Manuftcwar's Dats Ra m to bs inched CEITlCATH' OF COMPUIANCE I certify that the statemnits made in the report are correct and thnt this conforms to the requirements of the ASME Code, Section XL Type Coda Symbol Stamp N .Cardficate da, ? o 7R 9 Expgcn Date. Jan. 23/04 Signed A .Oatr 2)cA_ 9S ______&wner ov 0wnaisamnemITrit B Z CLql. t r_CERTIFCATE OF IUSERVICF INSPEcMON i, the undersigned,holding a vaind commission Issued bythe Naticral Board of Soilerand Pressure Vessel Insoectors and the State orProvince of a4L sendemployedby Ne,41 -AN ARP'AD BF2^-r AtJ7vtt'/Y of _ _ _ _ _ _ _ _ _ _ _ _ _ _ have Inspecd the components described In this Owner's Report during the period o r 17t 2-76. tt. 2 -,and ta t to the best of my knowledge and belief, the Owner has performed eamilitatons and taken corrctive rneasures described In this Owners Report in accordance with the requirementa of the ASME Code, Section XL By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report Furthermore, neither the Inspeor nor his employer shall be Hlible In any manner for any personal Injury or property damage or a bes-of anty Idnd arising fromn or connected with thIs Inspection. e Commissions Al 3 )v S Ns. xlA 62.Inspdctrs Signature Flatonal 8eard, State. Province, ald iEidasaments Oats A7e 2 9,6 ? I i Y.:-1 006 KNC 13 c7c/c/%-/" 53<676R IATEM? ?S PrvG-FS, KY S're9#/ Cp,',q&-,rSp Ti~Wc Gt1£ <E waxy Q( r 1 .2/I / I,,e %elo -.-o Q.A Q* - I-, 3 Problem Investigation Process Oconee Nuclear Station R da~b -lo lE -bi 1 0-04-03906 Problem Identification Discovered Time/Date: 12:24 06/07/2004 Occurred Time/Date: Unit(s) Affected: Unit Mode %Power Unit Status Remarks 2 3 0 2EOC20 SGR Replacement Outage System(s) Affected: RC Reactor Coolant Affected Equipment (No Equipment Affected)Location of Problem: Bldg: R Column Line: Elev: Location Remarks: OTSG 2A Nameplate Method Used to Discover Problem: Nameplate Unit No. discrepancy discovered during preparation of the NIS-2 form for the 2A Replacement Once-Through-Steam-Generator (r -TSG).rs ief Problem

Description:

Incorrect Oconee Nuclear Station Unit Number designation provided on the ASME code nameplate for the 2A OTSG (Nameplate has been incorrectly labeled "Unit 3").Detail Problem

Description:

The Oconee Nuclear Station Unit number designation provided on the ASME code nameplate by Babcock & Wilcox Canada (BWC) for the 2A Replacement-Once-Through-Steam-Generator (ROTSG) is incorrect. Unit "3" was incorrectly printed on the plate in lieu of Unit "2".BWC has confirmed with its ANI that the Unit number designation is supplemental information only and is not required by the: ASME code. The ASME required code stamped data (NI, NB 207 and Serial Number 006K-D3) is correct and is in agreement with the Form N-I Certificate Holders'Data Report. The location of installation is also identified correctly on the Form N-i Data Report as Oconee 2, Seneca, SC. SGRH's discussion with Oconee's Resident ANII also confirmed the acceptability of BWC's assessment. Given that the Unit number designation is not required by the ASME code, both BWC and Oconee's ANII concurred with SGRH's proposal to use a vibrating etching tool to engrave the correct Unit number designation on the ROTSG 2A nameplate. Thismerrective action was completed ---satisfactorily on 6/08/04. Both BWC and Oconee's ANII were informed following completion of the corrective action. A digital photo of the corrected nameplate was also taken and forwarded to BWC and to the Oconee ANTI.ROTSG 2B has been correctly identified with Unit 2 on its ASME code nameplate. BWC has confirmed that the ASME code :tamped nameplates for the Unit 3 Replacement OTSGs 3A and 3B have been correctly printed with Unit 3.Note: This PIP has been issued for documentation purposes and is recomme~nded for Category IV screening. No additional corrective actions are required.Originated By: MAH7380: HUTCHESON, MARK A Team: BKM7360 Group: SGR Date: 06/08/2004 O' -Units/Components/Systems/Areas Affected(Y.N.U): N...justry Plants Affected(Y.NU): U Immediate Corrective Actions: 0610812004 13.25 Page I PIP No: 0-04-03906 Problem Investigation Process Oconee Nucclear Station 8 n that the Unit number designation is not required by the ASME code, both BWC and Oconee's ANII concurred with S(GRH's proposal to use a vibrating etching tool to engrave the correct Unit number designation on the ROTSG 2A nameplate. This corrective action was completed satisfactorily on 6/08/04. Both BWC and Oconee's ANII were informed Following completion of the corrective action. A digital photo of the corrected nameplate was also taken and forwarded to BWC and to the Oconee's ANII.No additional corrective actions are considered necessary. Originated By: MAH7380: HUTCHESON, MARK A Team: BKM7360 Group: SGR Date: 06/08/2004 Imnmediate Corrective Action Documents I Work Orders: Problem Identified By: Problem Entered By: Indiv MAH7380 MAH7380 Team BKM7360 BKM7360 Grout Date SCR SGR 06/08/2004 06/08/2004 End of the Document for PIP No: The status of this PIP is: The duration of this PIP was: 0-4-3906 UnScreened I day-V 06/08/2004 13:25 Page 2 PIP No: 0-04-03906 06/OS2004 13.25 Page 2 PIP No: 0-04-03906 A-10 I!L-i P*. @._ t l , ss ,,, .,__ .............. _ ^-t' .§ _/ a , '. .(-1:- -<'_.. ._-.;4CLASS A , ; --.t -;tBOA.. Ro :._ = .""- ,'-.D.KE-PO Et,'ts ..-.:-0-: .DUEPRIARY SID : E --D E^ -0::3DESIGN PRESSURE : .2500PI ps[.................. 1050 PSIA 4"DESIGN TEMPERATURE -350cE : 60.0-F.-;41-711-YDROSTATIC T EST PRESSURE .3125 PSI 13.15- PS.I.;;L V111N. PRESSURiZATION TEMP. :100° F"' .: 100° F , ,^--s;-DATE BUILT 1971 gt.I J Z I;7 I .-.1;-:I-.1_1: Al.I i.i.i-i.., .i ,,,,,'., ;'_ \ ., , \ < 6 , 6 wW_ sJW i ^* # ;;_', , .., , ,- .. ;' ' ..., .' # ' '4, .-. , s.' .D- -* e e ... ;-e w .-..' .' :- ,* .;- , -* *6 Sv ,: ".v ...#, ...4 ..* o: o * ' .... ...: ................................... .,._ fi.... .-.Z.. .. ....-. , ... _-- .:.. ---.0 .-,. r-_ , , v _ ._ _ _.I,. .-.. ::. .--:. , -. Zl FORM N-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR VESSELS*As Required by the Provisilons of the ASME Code, Section Ul, vision 1 -Pg.1of6 W 1. Uanulactured and ceutmed by abcock & Wiox Canada. 551 CoaIon Boulevard. Cambridne. Ontario NIR 5V3.jU4X&Xa-&r*MotNC&AW~iaAHoUJ 2A1anufactured for Duke PovCklloan. P.O. Box 1008, Chariotte. Ncrth Caroina,282D1.006

3. Location of lnstalation conee2. Seneca, South Carolina 4. Type: Vet Heat EX -006KE01 Rev. 4 t E002 I v 1 v J20j 2003 5. ASME Code, Secdon 111, Divion t: eNna 1 _ Lst 41 At Items 6-10Indusve b be completed forasingl essels,,adwts o cdvesselrsflscf heat ge 6. Shea SA-50 CL 3a 9O ksI Lst #2 AIL Ust 2 At. List 2 Alt List 2 Al.ItrSra Ei) O4U4 aJI tmrl1hwmen (ZIa lUl 0C4I 1i 4J fnt IL#i X i7 List #3 7. Seams: Ust 3 AL UIstI3 Alt. Al. List3AtL Ust #3 Att. Ust 3 AL Ust 3 At 4 (rRT) K) f} t) --W. C-8. Heads: KIjnSec-W4 t4wUiQUI)o P rmr IYfSpK MJ(UMn Location top Thicn Coroson Crow"n Knuckle bottom, ends I ess wance Radius Radius If removable bobls used: 9. Jacket Closure: 10.Design pressureW 1150 Atmaxtenp." Iters it andl2mtbpiedfore sctmpiU oLns ( 11. Tubeshets SA-S0 a. 3a lsawna.se.u ri.1 -- 1 --_ _ther fastening I) se .I .a
  • qumsy (4eeztr~W alh&UtWc 60 ('f iu~cmu gawwnr rcu argwwm i~wce. @IMWt Mkr. pressure test WeMT 70 CF)Pneu., G or conmined test 1500 (Psi)t3754 l*LiLolitileDtuw~lm 22-3168 welded 111)(1-011 luadana4Kbok~l fi~as&( "l (aacud-011
12. Tubes S&B.BUNSINIM66S V 0.038 15631 _straight Wo. 14W Clowlv The~spg ~ (04 k (ga0100L1 Items l3tDl6 Incusive to be conplteed for innercharrdberso Jatjackted veselsorca isorheate xchangems l J. mile;________-

--Simgle Yes __FUR 14. Seams is.Heads--SA*508 CLa Se90ksl-lI') In *-IpGC Pmae siteaim W-Hfl3;-10a4 ovasierbngno KCX~Lspac-c liank stranA tol Location-() op bttom. Ws (c) Floating;-Thi'kesIConRdu Knuckde RadIus Elliptical Ratio Conical Apex WT]TZAnZle ..._ ..r , Imemnispriercai RadZu-Rat-Diat Diameter Sid to Pressure (convex or concave)concave concave I4 I*1.J It removable, bots used Other fastering (aua~ce ejca Iftl (voiln SWec fin size. QWA*))"19Zss -r4" 2500 a: 650 W. pressure-test lemp. 70 Pneu, lMm., or comb. Test pressure 3125 F F1F) (p* : Upost weld heat teated. 2 LisI other U t rnal or eesemna pressure wh coincident temrpe.atue rhen ppimable.* *Suppiernental kilSmtion In the torm ot lists, sketches. or drawings fay be usd prcvdecld (1) size is e X 1 1, (2) inlormation in items 1 hrough 4 cn this Dta Report is incuded CS each shee'. (3) each smeet is nurmneed and the number of sheets Is recorded on the Ioo of Uris form. ', FORM INM-(back P2g.; of 6 e Cerfflate Holder's Serial No. 006KO4 17. i'oles, Insoection and styvahe ks s.Purpose How-Rein forceI Hw l R rent rnleouue .drain. etc.) Ouanthy Dib. or size J Type arached Marl. _____ess I at-rit Location See Lstf4 _ _ _ _ __ _._ =__ _ _ -_ _ _ _ _ _ _ _ I. I _ _ _ _ _ _ __ _ _ _ _ ___l8.Support:Skkt SeeLIst#S Lugs SeeList#5 Logs -Other _ Atabded SeeList S (rorool (s y) h.rkl P fw l 19. Remarksr PreousN-2 FoTnms frthe Priay Heads IManufacturedbvJaan SealW s.Muroan Plant National Bwd Numbers 435 and 438 )atbded CERTIFICATION OF DESIGN Desbgn specfialmn certified by See List iS P.E. Stle See List #6 Reg. No. See LIst #6 Province Design reprr certdfled by J. T. Boyd P.E. Sa Ord. Re,. No. 04801502 CERTIFICATE OF SHOP COMPLLANCE We certify a the statements made In his report ae correet and that this nudear vessel conlormsto the rules honsM on pode, SectonUI 0 ision 1.N Certilicate oi Authorization No. N-2789 Expres _ /wK ..Ianuary 23 2004 Date Novernber7, 203 Name Babcock & Wilcox Canada Sqned 4 vc ,resuf- l (N Certificate Holder) lauthoized reosentatve) CERTIFICATE OF SHOP INSPECTION OlR the undersigned, holding a valid commisslon issued by the National Board ol Boiler and Pressure Vessel Inspedcrs and the State or Province of Ontario and emplyed by Technical Standardsand Saletv _Au of Ontarb hav hspected the cmponent desbed his Oata Rexo on 9Y3, andstatelhatttIhe Best of my b nedge ed belief, the Cerfata Holder has constructed UuisacomponentIn accordance wi the ASME Code, Se Uion W, Dion 1.By signing M aerlificale, neterthe Inspector nor his oyer a warranty reased or irrpled, concerning the ceaonent described In this Data Report Fuhrtermore, nter the inspector nor his employer shall be lablia in any nmnnerlor nat hruryor rtydamnage or bss at any ldnd orconmected with this i ospedn.Date Nov.7,2003 Signed Cornrssions / e o lf .j CERTIFICATE OF FIELD ASSEMBLY COMPUANCE We cey Wathe statements on this report ar coectand taWWhe field assbly Cnsucion of all parts of this nuldear vessel conforms tothe rules of constwfson ofthO ASUE Code.Section 1. Dhivsison 1.N Cerdiruate ofAuthortaflon No. _ Expires Cate Name _ Sgned IN CetFicate Holder) lauthorized representaetive) CERTIFICATE OF FIELD ASSEMBLY INSPECTION I1, the undersgned, holding a valid commission Issued by ta National Board of Bodler anrd Pressure Vessel inspectors and the State or Province of I __ and ewbpyd by '-of have compared Ihe statements in this Data Report with the described component and state bhat parts refered bo as data items____ __ _ __ __ _ _ _ _ _______- ,notindrain the cerfcateof shopo Ispefcin, havebee ispetedtbyineon and that to the best of my lmowkldge and belief the Certificate Holder has constructed and assertkiud this component In acoraance with the ASME Code, Secmon IM, OMsion I.By signing Mis cerlificate, netier the inspector ror his employer makes any warranty, expressed orri pled, concerning the component descrbed In this Data Rept. Furthermnore, neither the Inspector nor his emloyer shall be biable In any rmanner br any personal nIuryor property damusge or loss of any Kdnd arising from or connected with this kiqecti3L. Date Signed Commissions !^,,-em ,s, 19_.._ e.^

  • _.^__ .._.. __ _ .SX _ !Date Signed Commissions U,,^e_. --.... -_ ._. ...'

Attachment to FORM N-I CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR VESSELS As Required by the Provisions of the ASME Code, Section III, Division I'Z3 Crf 3 3-Pg. 3 016 1. manuftemd VWa ceflvad by 1~' 2.,Manufaot~rd for Duke 3. Lomban of tstaflatn 4. Type: Vertical*#'z.'wve Babcock & Wilcox Canada, 681 Coronation Boulevard, Cambridge, Ontario NI R 5V3 Power Comoanv. P.O. Box 1006. North Carorina. 28201-1006 Oconee 2 Seneca, South Carolina~Immuawsoug 0O6KE001 Rev. 4 &-006KE002 Rev. I Heat Exchanger 00604 pd4"I-W f:t"Wolwaw 208 2003 PM If~f~iflBn.NO4 Ust #1 N-204 N-474-2 2142-1 2143-1 LIst #2 Min. Length Cjer Nominal Design Inner section Length Thickness Thickness Diameter thickness) Overall Shell can below upper T/S 51/5 , 1 377/. 523/4' 131 13/16" (thick shell, adjacent to T/S, taper 3y/. 3" 137Wha 79 1/16" to thin shell) ______Thin Shell to Thick to Thin 31' 3D 137Y"a 19Y40 159I%5Y/; 5' 137W/a 112W'3%' 3" 1377W' 27'_Thin Shell 31/% 3' 137; -173%.Shell Can Above Lower T/S 3V" 3' 137W/" 106 7/16" 159 3/16" (thin shell taper to thick shell, 5'1A 5' 137" 52KW adjacent to T/S) _ = ... .Z 0733 AtUChment to FORM NI1 CERTiFICAT1' HOLDERS DATA REPORT FOR NUCLEAR VESSELS As Required by the Proviions of the ASME Code, SetOn i1. Dhslonrl Pg. 4 of 6 bv1 1. Manufac=Wred and cered by Babcock & Wilcox Canada. 581 Coronation BoulevatdCatnbfd 2'Mznuwafted for Duke Power Comoany, P.O. Box 1006, North Carolina, 28201-1006 rafrefaOc e S cS.1hCri 3. Locafon of kstalaron .Oconee 2. Seneca, Southi Carolhna aeOntait N1R5V3.;... w _ .41 006K001 Rev. 4 &-006KE002 Rev. i 4. Type: Vertical , talmhL0-Heat Exchanger 006104 0A*Wxk6T jC*LKc~f4S 208 2003 o-bd P% Iew"04 ptafb" List #3 Seam Longitudinal Joint HT RT eff (%I) Glrth Joint -T RT Type Type Tubesheet NIA NNA NWA (Forging) .Double Yes Full Shell Can #1 None Yes Full 100 Double Yes Full Shell Can #2 None Ye3 Full 100 Double Yes Full Shell Can #3 None Yes Full 100 Shell Can #4 None Yes, Full 100 Double Yes Full Tubesheet N/A NJA N/A N/A Double Yes Full (Forging)-- _ -%V.. te. ... , ,. ^ ^ ... ... RY_ 25- 33 Anachment to FORM N-1 CERTIRCATE HOLOERS' DATA REPORT FOR NUCLEAR VESSELS As Required by the ProvIsionS; of the ASME Code, Section Iii, Division 1 Pg. 5 of 6 1. Manufadmued and ceffid t Babcock & Wilcox Canada, 581 C oronation Boulevar, Cambridge, Ontario Ni R SV3 ti- up fmt~tdc !xai'seit, Iat 2blanudactred for Duke Power Company, P.O. Box 1006, North Carolina, 28201-1006

3. Locatfon of instaktdon Oconee 2. Seneca. South Carolina 4. Type: Vertical Pomit ovwz2.Heat Exchanger 006K04%1*jKM&W.

bis ) (Cat#k~I4~rWW41m 006KEOOI Rev. 4 &-008KED02 Rev. 1 1=P4 aW-4)208 2003 0XI31mi 6-6 List #4 Purpose n aeteufet. O. -D) Type HowAttctd matlertal (mh1) Reinforce ant Location drain, etc.) CID er Thiclcess Matehl .Pinra Nozzles Wef 1 36' I k&WW SA- C1. 3a 3' W/A UpperChan Head Pdrcy Nods lOutIit 2 26 F Welded SA-SOeCL3a 3Y' WA Lower Che Head Prbnary lnway 2 16' I ktal SAM5 8CL 3a , SA40B CL 3a Chen. Heads Pwryna yManway Cor 2 28W -God _ SA533Typ.BCL1 5W NWA CU Heads PrinfaqHardhhe 1 6. I kntel SA-5W CL3 3Y4 NWA UpperChan. _____ __ __ _____ emd Pfnmary Hedh* Cover 1 12W -owd SAS33 Typ.E CL I 2W WA Upper Chai Hesd Sacedy Haroles 5 6' I Inteal SA-508CL3a .NIA She!Handhle Covers 5 12Y' -Bow-d SA.533Typ.B CL 1 2W NWA She!kispeclion Pods 30 3 l intwal SA-5M CL3a 3 N/A Shell Inspedicn Pod Cors 30 6Y4S -Bolted SA-433 Typ. B CL 1 1.48' NWA Shel FewaterNzzles d by 32 4' -Welded/Idled SA-162 Gr. F224 0 N/A Shed external header AuxlaAyFeedwaterNozles 6 4' -Welded(Botted SA-t82 Or. F22 0. N/A Shell fed by eaemal header secendaryMarnQy 2 16' I gu SA-50MCL3a W NA She!Serdawldar ayCover 2 25W _ Bolled SA-33 Typ. B CL 1 3S WA Shal Steam Nozzle 2 22265' F Welded SA-M CL 3a 3W3S SA-508 CL 3a SheI InshrnentNozzias 7 1W F Welded SA 5.5 E7018 A1 0.41' N/A Shel InstrumantNozzes 12 1 F Welded SFA65E701SA1 OA5 NtA SheD MFW Inspecti Plugs F Welded SA-105 O0 SA-105 Shel DowncornerTenp Sensor 3 W NPT P Woe SA479 Type 316L 0a56s N/A Shel_ _ _ _ _ _ _ _ _ _ _ _fillng*n/a -no protruding sheR penetration F = full penetration weld I = integrally forged P=partial penetration weld..-r O.,n1 ..rn. Z-. - Tg 2~t 4w33 Attachment to FORM ti1 CERTIRCATE HOLDERS' DATA REPORT FOR NUCLEAR VESSELS As Required by the Provis ons othe ASME Code, Sectlon III, Divisio&I Pg. 6 ate 1. Manufctured and caulmed by Babcock & Wilcox Canada, 581 Coronation Boulevard, Cambridge, Ontario N1 R 5V3 2X3nufched for Duke Power Company, P.O. Box 1006, North Carolina, 28201-100 3. Location of inslaton Oconee 2, Seneca, South Carolina 006KEO1I Rev. 4 &-006KE002 Rev. 1 4. Typ: Vertical Heat Exchnaer 006K,04" "W U (cOhoUtiwfb 208 2003 bwbu W IMGmfroIaldN List 15 I=_ _ -= .Description Skirt Lugs Legs Attached (where &__yes or no) (qty.) (qty.) how)Lower Shroud Lugs No 12 -shelftsded Upper Shroud Lug Yes --sheWilingrd-Odice Ring Lug Yes _ -shel/irtWgal Lower Primary Head Base Support Yes _ -channel headfinteral WMst16 Name State Reo No.lM. C. Keck N.C. 13S67 J. C. Herrin N.C. 14504 4----IV VP 'iv FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production Pg.1 of 2..Anufacture~and erified by The Japan Steel Works, Ltd., Nmroran Plant/4-Ciatsu-:cniXlo:r~H rcO5-60 j8t nams .nd admsess oft !i4T C.tcaie 4Ofl 2. Manufactured for Babcocc S Wilcox, 581 Corona.tion Blvd., Canbridge, Onaato, XIR SV3, Cazea (a~ams and adtlen of04=411 3. Location of installetion OCone, Nuclear Power Plant Unit 1, 2 & 3 Oconee, South Carolina hInsng and addressI 4. Type N48361W, Rev. 2 SA-508, Cl. 3a _ in. 9Oks'1 -200 (crowing no.) tInorL soec no.) I lmie suggt.1h1 ICRNI lf t 5. ASME Code, Section III, Division 1: 1989 No addenda 1-lsaidan) laddend aut) tas) tCoCeCade no.l 6. Fabricated in accordance with Const. Spec. (Div. 2 only) _ Revision D _ ate 7. Remarks:

  • fydrostatic test Ls not performed.

in The Japan Steel Works, Ltd.Cladding thickless in man. 0.20" from base metal.Cladding materials are SPA-5.4, AHS Cl. E309L-16 + E308L-16 and SFA-5.9 E2309L 4 ER308L.S. Norn. thickness (in.) 6-3/8iL Min. design thickness (in.) 6-1/4" 5b. ID (ft & in. 9'-. 1,75" Leng-h overall ft & in.) 7'-{0 P7" 9. When applicable, Certificate Holders' Data Reports are atitched for each item of this report: Natiooal Part or Apourtenance Board No.Serial Number In Numerical Order 1057 436 (2)(3)(4).(5)(6)(7)(9)(10)(11i)(1 21 _ _(23)(14)(15)(21)(22)(23)'_(24)(25)National Part ar Apourtenlance Board No.Serial Number in Numerical Order (26)_ -(27)(28) _(3tt)(311 (32) ---(33)(34)(35) 9: (361 Nn{^t nr§:§(371 138) _______2W 2 (39)(40)(41) ' -t____(42) AP_ 2 'E0 (43)1447 (45)_(471 (481 (50) ._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ I -_ _ _ _ _ _ _ ._ _ _10. Design pressure UA psi. Temp. N/P 'F. Hydro. test pressurc -n/A -at temp. 'F twt.4n apoplc)Ole

  • Supplemental Informetion in the form of lists. sketches, or drawings may be used provided (1) size is 8'Y2 t t. (21 Information in Items t and 3 on this Oats Report is included on eech mseet. (3) each sheet is numbered end the numrer of sheats is recorded It the top of this form.(71181 This tfarrt (E0040) may be obtained from the Order Dept- ASM£. 22 Law Orive, Box 2300. arifield.

NJ 07007-2300. jj11 jIIill111' P.O. No. 0: C0313634 JSW Job No.. : FN9-430S E00040 Heat No. : 000497-1-1 JSW PC. No. : 4 7e /2-v J- 33 FORM N-2 (Back -Pg 2 of 2: 2 -Certificate Holder's Seritel Nos. 1057 throug -CERTIFICATION OF DESIGN Design specifications certified by K"A P.E. State S/A Reg. no. N/A Design repor;- certified by t /A P.KE State NA Rag no /A CERTIFICATE OF COMPLUANCE We certify that the statements made in this report are correct and that this Ittese) Part conforms to the rules of construction of the ASME Code. Section ill. Division 1.NPT Cenificate of Authorization No. N-2725 Expires 2ute t9, 2004 The Japan Steel Works, Ltd.Date Nov. 2. 2001 Name Muroran Plant Signed VN/T Cartficaut HCai- nzed rM"s, tativet J. Taira C ERTIFICATE OF INSPECTION

1. the undersigned, holding a valid commission issued by the National Board of Boiter and Pressure Vessel Inspectors and the State or Province of ILLIOIS and employed by H.S.8.I. s Co. 3 of JABTFOEID.

C:. _ .have inspected these items described in this Dats Report on .1 L , : L. and *tae that to the best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances in accordance with the ASME Code, Section lI, Division 1. Each part listed has been authorized for stampilng on the date shown above.By signing this certificate, neither the inspector nor his employer makes anywarrenty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any perso -al injury or property damaop or loss of any kind arising from or connected with this inspection. W ..,..: .Date Signe~(Auerwrizea NtUWr insiecwrl Commissions NB10104, N, B, A gNarL ad. fncL andcmenuaJ ad sate or sgtov. and no.)A' 4vefc 6r YC7 i4 ek-Mah^ut idurf'n, '0/b2 /01'-T e /- %/f /o /orj Lv4snor LU;41 Y-/7r, ellaAc w Pae, A//°/a 36 (,J, XeA j INCOMING iNSPECTION JAN I I 2012 O.C. I l_APPROVED_ WW-r z,7 FORM N-2 CERTIFICATE HOLDERS, DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES-As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production Pg. 1 of : 1. Manufactured and co-iified

  • he ,Wpeci Steel Works, Ltd., Muroran Plant/4 atst,&tSU-z;ct:, , , i -- Z ;_inamea f anadoorau ii NP, :an.,g-ec'
2. Mainufacturtc

',or s acock & Wi+/-:cox,, 551 Co-rocation Kvd- , Camtbridge, Ontaxi-o, NI 513, a e WMam ano acdrau o c@1 p%11i341-. Lcca:ior, of installa.:on Oconee NIfcloax ?over Pla.:nJt 1, 2 & 3 Ocotee, Sout~h Carolina__ .snamre mo ¢acca 4. Tye __ SA'309, Cl. 3a Y+/-4=. 9_k_ _ 2 0 I Wirtria; ac.t (IO3L SOcK *4j.i tt asih StranthU iyear btUi 5. ASME Code, Section lil. Division 1: !989 No addenda _laditionl lrcdno ataal class! 7Coc. Case a1o.1 6. Fabricated in accordance with Const S-ec. (Div. 2 only) Revisiont -_ _ Date 7. Remarks: *Hydrostatic test is not performed In The Japat Steel kforks, Ltd.Claddzig thic)caess is mtn. 0.20" i.rom base metal.Claddlng mater2als ane SFA-5.4, AMIS Cl. E-O0L-16 4 E308L-16 and SFA-5.9 E309L + EF308L.8.S.Nom. thickness lin.) 6-3/8" Min. design thickness lin.) 6-1/4" Dia. ID (ft & in.) 9'-1 ,75 Length overall (ft & in.) V -2*55 When applicable, Certificate Holders' Data Reports are attdched for each item of this report National Part or Appurtenance Board No.Serinal Number in Numerical Order 1056 435 13)(4)(51-(7)(98)(91 l1D I Il _ _ _ _ _ _ _ _ _ _2141'.251 120)121)(2z).231 1241 -_!251 National Pan or Atipurtenance Board No.Serial Number in Numericei Order (28) 1 _ _ _ _ _ _ _ _ _ _ _(29) _ _ _ _ _ _ _ _ _ _(30)(32) -(37)138) _ _ _ _ _(401 0r4ULIyfIhfC Hi ~ECTION I _____143) .. -' _ _ _ _ _(44) _ _(45) ..i (46) APQQ.QVn (4 7 ) _ _ _ _ _ _ _ _ _ _ .' _ _ _ _ _ _ _ _ _ _148i I ,49l _ _ _ _ __ _ _ _ _ _(SO ____________ 0...____________

10. Design pressure N/A psi. Terrp. -V/A*F. Hydr:. test pressure -_ N/ at ierK:. 'F Jwnqft 4*r.asolae:

' Supolemenetsl information in tne form a' lists. sketches. or orawings may oc used provided (1) size is 8! a 11. :21 inlarrnetion in items 2 and 3 on tnis Data Auoon fs induced on erin sheet. 131 aech shea is numbered and the number of slhors is 'ecorod a- the top of this form.71981 This form triOO01 may be obtained from the Oroer Oer1L. ASME. 2- Low Orive, Box 2300. Faifield. NJ C7CC --3CC.^ P.O. No. : n313634 JSR Job No. F149-4304 Hiaat No. : OD426-1-1 JSW PC. No. e 4 E00040 FORM N-2 (Back -Pg 2 of .1 ( L Cert'ficate Molder's Serial Ncs. 056 :hrmugh --CERTIFICATION OF DESIGN Design specifications cerified iy St P.' S ate i/ Fe. nc. Ii/A Desigr. report* certified by N/A -F.E. State --A Re;. no. N.";, Iwftn imiaotaO)CERTIFICATE OF COMPLIANCE We cenify that the statements made in tnis repors are correct and that this (thesci ---confcrmc to the rules of construcdion of the ASME Coct, Section Ill. Division 1.NPT Cetificate of Authorization No. Expires Juc2 29, 2Q04 The Japan Steel Works, Ltd.Date Set. 1 2C21 Name HurDran Plant Signed (NFT Cerca5rte 140152?)CERTIFICATE OF INSPECTION

1. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Provin cf ILLINOIS and employed by H.S.B.I. & I. Co.of_ HARTrO. CT. have inspected these items described in this Data Report on ° and state that to best of my knowledge and belief, the Certificate Holder htis fabricated these parts or appurtenances in iccorda.-ace witb the ASME Code, Se-o Ill Division 1. Each part listed has been authorized for stamping on the date shown above.By signing this certificate, neither the inspector nor his emeltoyer makes any warrany. expressed or implied. corcerning the equipment describ;in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or propefty d or loss of any kind arising from or connected with this inspection.

Date et L.net a S ignLe F Commissions t NAuUotimd gear Irwnspc N21O104, N, B, A IN:11. ad. Un~c). u,,dowaaeni) and satae or brev. ant nZ.;3 J 4-viAe 4 ,I S'f % -. SJ I M r'I II!, %e .,r-, 'K -IIQ.C. 1 i APP'ROVED/10 hesden io At.,.--I o-i~~r vhhAlc41A.A K F3*' o9.33 FORM NIS-2 OWNER'S REPORT FOR REPA1RIREPLACEMENT ACTNTY As Required by the Proviions of the ASME Code, Section Xi 1. Owner Duke Power Comnanv tName_2.PO Box 1006. n~sp-lnt~t!c7O-1Oo K, 2qniin _Ageus Oconee 2 Plant NamI Seneca, South Carolina.ovember 7, 2003 Data Sheet I of -Unit 006ZO4 208 A*UM -r =rauamaC n P.C. NM. .tt No. M-.3. Work Ferfdormedby Babcock & Wilcox Canada _ Type Code Syrnbl Stamp N-_Authorizatn No. N-7RCa 581 Coronation Blvd.. CaMbridrae. 0t1t. NlR5V3 Expiration Cate On .4. Idenarfication of System 208 5 (a) Applicable Construction Code ASM Sec III 1989 *Editon, Addenda, -Code Case Ib)ApplcableEditonofSecdonlUtfldiedfor RepalrtReplacement Aivty 1998 -2000 Addenda Yew Ic) Applicable Section Xl Code Casm -6. Identification of Components: NadoNI I Cogrced, dASM Name of M Nme of Manufacturur Board jI ec Year RemoeVt u r Stamped Component Manufacturer Serial No. No. -Other Idifdficalt Instailed (Yu or No)Heat Exchanger B&W Canada 006K04 208 N/A 2003 See Below Yes___I _1, _ _One prim. inlet nozzle, two prim. outlet nozzles weld cladded. and final machine 7. Description of Work PWHT not performed. Two steam outlet nozzles final machined. -L. Tests Conducted: Hydrostatic a Pneumadc a Nominal Operating Pressure 0 Exempt O Other C Pressure psi Test Temp. *F NOTE Suppler.ental sheots in form of lIsts. sketches, or drawings may be used, provided (1) size Is 8'/z In. x 11 in, (23 Information In items 1 through 6 on this report Is Included on each sheet, and (3) oach sheet Is numbered and number of sheets Is recorded at the top of this form.171/51 Thd form ( E00030 may be obtalned from the Order Dept, ASME. 22 Law ODve. Box 23C0. Fairfield, NJ 070072300. IM I N ORI1 1 EOG030 7' '< 32- X3 3 FORM I1IS-2 (Back)I%% 16 bIl N A0p!lcaa ManufacsunWS Data Ietns; to beasmcfed CEOIMFICATS OF COMPUANCE I certify that the statements made In the report ere correct end that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbo( Stasp N CertifcNf-A2789Expiration Dat Jan. 23/04 Signed 7Q, { Sou r (2A 1tIJ6A 'D~e J\AA ? , 2-&Owner /ei1 e Titl ne , 17d CERTIIICATE OF INSERVICE INSPECTION i, t undenrlgned, holding avalid commisslon issued bythe atlonal Roedof ioflewnnd PressureVsssel Ins ectora ndthl State r Priince rAu 7zip and employed by /MY A14A 4 ST A_,, _ _ __ A,4___ _A_ _ _ __Y____of a AR .We_ _ havl n, ar."d the components described In this Owner's Report during the period £'Xt -* , d 2. and stats that to the besa of my knowledge mn4 baIef, the Owner has perfcrmed examilnations and taken correctve mneasures d-scribed ln this wner's Report In accordance wkth the requiremenra of the ASME Code, Sectton X?.By signing this certificate neither the Inapector nor his employer maltes any warranty, expressed or implied. concerning the exminations and corrective measures described in this Ownef s Repor; Furthermore, nelther the Inspector nor We employer shall be liablo In any manner for any personal Injury or property damage or a loss of any ind arising fom or connected with this Inspection. commisselos M6 41/f' AWS AB75 652-V lpaor's Signauru Date M014 s 7' 2 ol Natonal scant State, Provinr, and 6n2&inents.W LQO j 7 70cC Uc 7- C C AZ AV nil (2°3 #11 'K_. f-q p S MrM .T -l M -~ p -K- - IC-(*pI .-Fle Whdow He i IC r p =6 p - c r---A C -C FORM NIS-2 OWNER'S REPORI (. REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xi I4 1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 1.a Date 09/21/04 Sheet I of 2 2a. Unit r 1 P 2 r3 r Shared (specify Units 3a. Work Order # 98539671 3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1008 Type Code Symbol Stamp NIA Authorization No. WA Expiration Date N/A Repair Organization Job #3b. NSM or MM # ON-23086 AS1 WP23050A 4. Identification of System Reactor Coolant Class 1 5. (a) Applicable Construction Code ASME iIi NC 1989 Edition WA Addenda, No Addenda _ Code Cases N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)
6. Identification of Components Repaired or Replaced and Replacement Components Column 1 Column 2 l Column 3 Column.4 Column 5 Col. 6 Column 7 Column 8 7 ~~~Natlonal AM Cd Manufacturer Boatrdonhar Y r 'Repampred , Rep(ayee, Stam pas Name of Component Name of Manufacturer Serial Number Number Identification Built or Replacement or no)1v Repaired 7 No Hanger/Support F Replaced 1 Yes A 2-50-RCPM-H6604 Duke Power Company WA WA WA 1974 r Replacement rp Repaired rv No Hanger/Support F Replaced r Yes B 2-50-RCPM-H6605 Duke Power Company N/A NA WA 1974 r Replacement rRepalred r No r Replaced F Yes C r Replacement rFRepalred r No r Replaced FYes.r Repaired F No.F Replaced F Yes E .__ _ r Replacement r Repaired r No F Replaced F Yes F _ _ _ Replacement Page 1 of 2 a Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and tlhe number of sheets is recorded at the top of this form.7. Description of Work Removefreplace supports for removal of Interferences for SG 2A removal.8. Test Conducted:

r Hydrostatic r Pneumatic Ir Nominal Operating Pressure r Other 1v Exempt Sheet 2 of 2 Pressure __ psig Pressure _ _ psig Pressure _ _ psig Test Temp ..OF Test Temp 'F Test Temp OF 9. Remark: Hangers were removed for the removal cf the 2A SG and replaced after Installation of the new replacement steam generator.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xi.Type Code Symbol Stamp N/A Certificate of Authorization

p. N/A Expiration Date N/A Signed O Date ZZ-/o4 CERTIFICATE OF INS ERVICE INSPECTION I, the undersigned, holding a valid commision Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of toC_ and employed by B-CZ have inspected the components described in this Owner's Report during the period 2-74 d to 5I) and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a lo ;s of any kind arising from or connected with this Inspection.

Commissions Ate 953, A) J X Inspector's Signature Date q-CR -&y National Board, State, Providence and Endorsements Page 2 of 2 c c It p-- II S=E 3 a C C FORM NIS-2 OWNER'S REPORI ,PR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xi I4 1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 l.a Date 09122104 Sheet 1 of 2 2a. Unit F17 Pr2 r3 r Shared (specify Units I 3a. Work Order # 98539673 Repair Organization Job #3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1005 Type Code Symbol Stamp N/A Authorization No. NWA Expiration Date N/A 3b. NSM or MM # ON-23086 ASI WP23050B 4. Identification of System Reactor Coolant Class 1 5. (a) Applicable Construction Code ASME III NC 1989 Edition WA --Addenda, No Addenda /Code Cases N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)
6. Identification of Components Repaired or Replaced and Replacement Components Column 1 Column 2 Column 3 Colum olumn l Col.6 Column 7 Column 8 7 ~~~~~Nationa SECd Manufacturer nar"l hntherIr Repa, Rep- acea, Stampe Cyes Name of Component Name of Manufacturer Serfal Number Number IdentIfIcatlon Built or Replacement or no)17 Repaired r No Hanger/Support r Replaced r Yes A 2-50-RCPM-H16606 Duke Power Company N/A N/A N/A 1974 r Replacement E Repaired 17 No Hanger/Support r Replaced -Yes B 2-50-RCPM-H6607 Duke Power Company WA NIA N/A 1974 r Replacement F Repaired r No.r Replaced r Yes c .r Replacement r Repaired r No F Replaced F Yes D Fr r Repaired r No r Replaced r Yes E r Replacement r Repalred r No rReplaced r Yes F FP Replacement Page 1 of 2 I Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/ in. x I11 in. (2) Information in items 1 through 6 on this report is Included on each sheet, and (3) each sheet is numbered and the iiumber of sheets is recorded at the top of this form.7. Description of Work -Remove/replace supports for removal of Interferences for SG 2B removal.8. Test Conducted:

r- Hydrostatic rF Pneumatic r Nominal Operating Pressure rF Other P7 Exempt Sheet 2 of 2 Z Pressure _____ psig Pressure ______ psig Pressure ______ psig Test Temnp ..O___ F Test Temp ____ 'IF Test Temnp .O 9. Remarlt -Hanciers were removed for the removal of the 28 SG and replaced after Installation of the new replacement steam generator.(Applicable Manufacturer,13 Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.Type Code Symbol Stamp WA Certificate of Authorization No N/A ~ ,Expiration Date N/A Signed ~ A L / ' ' ~Date (CERTIFICATE OF INSER'/ICE INSPECTION I, the undersigned, holding a valid commision issued by the Na tional Board of Boiler and Pr surVse Inspectors and the State or Providence of ____and employed by ~~ 4 L________________have inspected the components described in this Owner's Report during the period 0aZ-_-Y to ~L;and state that to the best of my knowledge and belief, the Owner has performed examinations and tkn corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate, neither the Inspector nor his errployer makes any warranty, expressed or implied, concerning the examinations-and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss oy! any kind arising from or connected with this Inspection. .......... I lnipeftoes Signature Date National Board, state, -Providence and Endorsements Page 2 of 2 r 4 p llil .aLA ~ -'-"mM p ..3. ITTO TWA uia -r FORM NIS-2 OWNER'S REPOP'7- 9 REPAIRS OR REPLACEMENTS As Required By The Provis 1 Jf The ASME Code Section Xi.. i 1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 1.a Date 09/22J04 Sheet 1 of 2 2a. Unit r 1 Pr 2 r3 r Shared (specify Units 3a. Work Order # 98532391 Repair Organization Job #3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A 3b. NSM or MM # ON-23086 AM4 WP 23065A 4. Identification of System Reactor Coolant Class I 5. (a) Applicable Construction Code ASME III NB 1989 Edition N/A Addenda, No Addenda _Code Cases N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)
6. Identification of Components Repaired or Replaced and Replacement Components

_ _Column 1I Column 2 I Column 3 1Coiumn 4 Column 5 Cal. 6 Column 7 IColumn 8[ I National 1 -Manufacturer Board Other Year Repaired, Replaced, Stamped (yes Name of Component Name of Manufacturer SerIal Number Number IdentifIcation Built or Replacement nor 0 17 ~Repaired N rv WP No r Replaced r Yes A Piping Duke Power Company N/A N/A N/A 1974 r Replacement rRepalred r No FrReplaced Ye B _ _ _ _ _ __r Replacement __Ye r Repalred r No r Replaced r Yes C rReplacement r Repalred r No r Replaced r Yes D .__ rReplacement r Repaired r No Fr Replaced FYes E .-r Replacement r Repaired F No r Replaced r Yes F ._ r Replacement Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Re-install reactor coolant piping for SG 2A.8. Test Conducted: r Hydrostatic r Pneumatic 177 Nominal Operating Pressure r Other r Exempt Page 2 of 2 Pressure _ _ psig Pressure _ psig Pressure _ psig Test Temp OF Test Temp _ _ OF Test Temp OF 9. Remark: Existing reactor coolant piping had to be removed to allow removal of old SG and Installation of the new 2A steam generator. This NIS-2 covers the welding for re-lnstalling this piping. Applied Code Case IN416-1.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the tules of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization No. "AA 6G-r-" 5eE^&ktr: Expiration Date N/A Signed Hi_________________ Date q .., I I CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commision iqsyed by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of N coo and employed by Mz or have inspected the components described in this Owner's Report during the period ,j-/30!to Siw-olJ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. ___nmmiqinnq Nia 3. A). _ , Ins eto'esignature Date q_,9q_ og National Board, State, Providence and Endorsements Page 2 of 2 i I Jr rt-I f p__ r FORM NIS-2 OWNER'S REPO9 ) R REPAIRS OR REPLACEMENTS As Required By The Provi , is Of The ASME Code Section XI r 1. Owner -Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 1.a Date 09/22/04 Sheet 1 of 4 (Taylor Forge Elbow 2A)2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 2a. Unit r 1 Pr2 r3 r Shared (specify Units 3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. NIA Expiration Date N/A 3a. Work Order # 98532391 Repair Organization Job #3b. NSM or MM # ON-23086 AM4 WP 23065A 4. Identification of System Reactor Coolant System Class 1 5. (a) Applicable Construction Code ASME III 1989 Edition N/A Addenda, No Addenda -Code Cases N-474-2 (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)

6. Identification of Components Repaired or Replaced and Replacement Components Column I Column 2 1 Column 3 -Column 4 Column 5 Col. 6 Column 7 Column 8--ia AME C Code lv- uiaer year Repaired, Replaced, Stamped (yes Name of Component Name of Manufacturer Serial Number Number Identification BuIlt or Replacement or no)r- Repaired r- No T Taylor Forge r1 Replaced F o Taylor Forge Elbow EngIneered Systems, .NA 2004 Replacement I Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information in items 1 through 13 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.Sheet 2 of 4 (Taylor Forge Elbow 2A)7. Description of Work Replaced Unit 2 'A" RCS Hot Leg 1n 5 Degree Elbow 8. Test Conducted:

r Hydrostatic r Pneumatic 17 Norminal Operating Pressure r Other r Exempt Pressure _ _ psig Pressure _ psig Pressure _ _ psig Test Temp___ OF Test Temp _ _ OF Test Temp _ OF 9. Remarks: Applied Code Case N-416-1.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the ru.es of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization Ng. N/A Expiration Date N/A Signed iE S4 Date5'E t~A.L ~0-d~ Dat q/zz/o4-CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commision issued by the National Board of Boiler and P sure Vessel Inspectors and the State or Providence of t and employed by

  • Fir, have inspected the components described in this Owner's Report during the periodaITi3 9 toiyf I ITy; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Coce, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

JA 1, Cmmissions IS. D~3 i, A)7.-.z-InspeDatcsigpature Date !2 !7Al2 °o National Board, State, Providence and Endorsements I JAK/03-22-04/o 1 Page 312of 1 OZ-FORM NPP-1 CERTIFICATE HOLDERS' DATA REPORT FOR FABRICATED NUCLEAR PIPING SUBASSEMBLIES* As Required by the Provisions of the ASME Code, Section Iii, Division I Pg. I of 2 11111... -..- --1. Fabricated and certified by 2. Fabricated for 3. Location of Installation TAYLOR FORGE ENGINEERED SYSTEMS, INC., 208 N. IRON STREET, PAOILA KANSAS 66071 SGT OCONEE P.O. 817 SENECA, S.C. 29679.(nanr aid address)DUKE POWER COMPANY SGT OCONEE NUCLEAR STATION 155 E PICKENS HIGHWAY SENECA. S.C. 29672 (nane amd address oPurchaser)

4. Type: 806050- ID (CRN)806050-1 Di R/4 (dMWMn no.)_____________2004 (Nail. ld~no.) (yewbuill)(Cerl. Holders ai no.)5. ASME Code, Section III, Division 1: 6. Shop hydrostatic test-1989 1 N-474-2 lediion) (addenda da) (class) (Code Cs na)3200 Psi at 70 OF (if performed)
7. Description of piping RCS HOT LEG 145 DEGREE ELBOW 8. Certificate Holders' Data Reports property identified and assigned by commissioned inspectors have been furnished for the following items of this report 9. Remarks: OCONEE STEAM GENERATOR REPLACEMENT PROJECT CERTIFICATE:

OF SHOP COMPLIANCE We certify that the statements made in this report are correct and that the fabrication of the described piping subassembly conforms to the rules for construction of the ASME Code, Section III, Division 1. ag NPTCertificate ofAuthorizationNo. N-1937 expires November25 , 2004.Date .z Name TaylorForaeEnaineeredSvs ters.nc.(NPT Cerhiicale Holder)Signed __I_.."_____________________ autthoqltzed rfesent. )CERTIFICATE OF SHOP INSPECTAN " 1'I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Kansas and employed by HSB CT of Hartford, CT _ _ , have inspected the piping subassembly described in this Data Report on s /or/d o C ,and state that to the best of my knoveledge and befief, the Certificate Holder has fabricated this piping subassembly In accordance With the ASME Code, Section III, Division 1.By signing this certificate neither the inspector nofis employer makes an aanty, expressed or implied, concerning the piping subassembly described in Oils Data Report Furthermore, neithe r or his employeshe be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with ,in *on Date t53/0 /l Signed ____ Commissions 14 ___ _ __ __ A?/ I (.- Dh .,.AI4GA fl-' AM-1* Supplemental information in formn of lists, sketches, or drawings may stusetd provided (1) size is 8 %/ x 11, (2) information in items I through 4 on this Data Report Is included on each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form.t N .0, 3 C 6 V r CI ktrOg -tc 7- A) IIIIIN I FORM NPP-1 (Back -- Pg. 2 of 2 )Certificate Holders Serial No.806050 -ID 10. Description of field fabrication

11. Pneu., hydro., or comb. test pressure _ psi at temp. __ ¶ (if performed)

I tP~lDTICIIATC nF CIm n CA 12f1tATtnUl tIfMPI IAUhIU ,Wr6% 1 IrW,% IL.W Ir rHCL.W I PW A &^ Iv M-IWWFV 161PUVW We certify that the statements on this report are correct and that the field fabrication of the described piping subassembly conforms with the rules for construction of the ASME Code, Section III, Division 1.NPT Certificate of Authorization No.Date Name Exoires_-wTr Signed tCnttifirA wrladrl Isithfrbod rerrwAntwfiVP1 CERTIFICATE OF FIELD FABRICATION INSPECTION I ' undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province IBM_ and employed by of_ have compared the statements in this Data Report with the described piping subassembly and state that parts referred to as data items , not Induded in the Certificate of Shop Inspection, have been Inspected by me on , and that to the best of my knowledge and belief, the Certificate Holder has fabricated this piping subassembly in accordance with the ASME Code, Section III, Division 1.By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the piping subassembly described in this Data Report Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection. ginnid Commissions (Aiffivi-d In.n.-IrA IN.-VI PA rwl and,~rtWI all m ~ W.I P t O, .LL* FORM NIS-2 OWNER'S REPC A R REPAIRS OR REPLACEMENTS As Required By The Provie ;is Of The ASME Code Section Xi k 1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 1.a Date 09(22/04 Sheet 1 of 2 2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 2a. Unit r 1 0 2 F3 r Shared (specify Units 3a. Work Order # 98532393 Repair Organization Job #3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp NWA Authorization No. N/A Expiration Date N/A 3b. NSM or MM # ON-23086 AM4 WP 230656 4. Identification of System Reactor Coolant Class 1 5. (a) Applicable Construction Code ASME Ill NB 1989 Edition N/A Addenda, No Addenda /Code Cases N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)

6. Identification of Components Rep ired or Replaced and Rep acement Components Column 1 Column 2 Column 3 -ColumTn 4 Column 5 Col. 6 Column 7 Column 8lNationa ASME Code Manufacturer Board Other Year Repaired, Replaced, Stamped (yes Name of Component Name of Maniufnotr Ier! KpvkNomhr I.- Nabdtift-on-l

-- s. .I Seri....u.bse*S ......... o BuIt Ue t I low]F7 Repaired 1v No r Replaced r Yes A Piping Duke Power Company N/A WA N/A 1974 r Replacement r Repaired F No r Replaced r Yes B r- Replacement r Repaired r No r Replaced r Yes C F Replacement r Repalred r No r Replaced r Yes D r Replacement r Repaired r No r Replaced F Yes E -r Replacement F Repaired F No r Replaced r Yes F 1 Replacement Page 1 of12 Form NIS-2 (Back)Pace 2 of 2 NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 112 in. x 11 in. (2) Information in items 1 through 'B on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Re-install reactor coolant piping for SG 2B.8. Test Conducted: Hydrostatic r Pneumatic P Nominal Operating Pressure r Other r Exempt-Pressure psig Test Temp _ F Pressure psig Test TempO Pressure psig Test Temp OF 9. Remark: Existina reactor coolant piping had to be removed to allow removal of old SG and Installation of the new 2B steam generator. This NIS-2 covers the welding for re-Installing this piping. Applied Code Case N-416-1.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the riles of the ASME Code, Section Xl.Type Code Symbol Stamp NWA Certificate of Authorization No. N -{;2 6. Expiration Date N/A Signed 2 4 X CoI.LEt Date_ _______CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commislon iosued by the National Board of Boiler and Presure Vessel Inspectors and the State or Providence of /wz and employed by 7 have inspected the components described in this Owner's RepM during the period ;-/3- 041 to 4 7-04 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. __ Commissions A3 ) i, 2 Inspectos Signature National Board, State, Providence and Endorsements Date 1II°L Page 2 of 2 Ir I I -I -_ 1 --. ..9......n_... _ -__ .t -Enoll*l f lIl*llEiMe f5, rien SG RH Edit/)View Weld Record Data P7ckag 30S5B 3658 RCS MACHINING I WELDING SG 2B ANII W P Approval ; Continue ro ...-II I I - ;- -: &~ , Go To W eld ' -ackg(Z : : : ~ r 3 ;-,,' fNDE1/4 7 SDw='11 77 6% i '17 Cr-FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Prr I is Of The ASME Code Section Xi 1 .Owner Duke Power Company Address 528 S. Church Street, Charlotte, NC 28201-1006 1.a Date 09122104 2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 Sheet 1 of 4 (Taylor Forge Elbow 2B)PI2 2a. Unit r13 r Shared (specify Units 3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. WA Expiration Date N/A)3a. Work Order # 98532393 Repair Organization Job #3b. NSM or MM # ON-23086 AM4 WP 23065B 4. Identification of System Reactor Coolant System Class I 5. (a) Applicable Construction Code ASME III 1989 Edition WA Addenda, No Addenda /Code Cases N-474-2 (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)

6. Identification of Components Repaired or Replaced and Replacement Components X Column 1 Column 2 Column 3 Column 4 Column Col. 6 Column 7 [ Column 8 Nationa ASME Code Manufacturer Board Other Year Repaired, Replaced, Stamped (yes Nameo ComponentfFsimA
1. -S e ........u.m t r Uai" b 6 uu identilication Bullt or Replacement or no)Taylor Forge r Repaired r No Taylor Forge Elbow Engineered Systems, r Replaced F7 Yes 2B Inc. 806050-1F -A _ 2004 1v Replacement

-- -- ---- I Form NIS-2 (Back)NOTE: Supplemental sheets In form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 In. x 11 in. (2) Information in items 1 through I on this report is included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of.this form.7. Description of Work Replaced Unit 2 "B' RCS Hot Lea 145 Degree Elbow Sheet 2 of 4 (Taylor Forge Elbow 2B)B. Test Conducted: r Hydrostatic r Pneumatic 1 Nominal Operating:Pressure r Other r Exempt Pressure _ _ psig Pressure _ _ psig Pressure _ _ psig Test Temp _ _ OF Test Temp _ _ 0 F Test Temp _ -F 9. Remarks: Applied Code Case N-41 6-1.(Applicable Manufacturers Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct aind this repair or replacement conforms to the rules of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization No.g A Expiration Date N/A Signed SDate , zz -tI CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commision issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of M _- and employed by 2+/- ZJQ have Inspected the components described In this Owners Report during the periodo'bazo to -: and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate, neither the Inspector nor his employer' makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind ansi from or connected with this Inspection. Commissionso3( D?5'a, 22 nspect s Signature National Board, State, Providence and Endorsements Date 2M i ,;( -I!dAl UOp-4 l-VatV I FORM NPP-1 CERTIFICATE HOLDERS' DATA REPORT FOR FABRICATED Pagers of 'f/NUCLEAR PIPING SUBASSEMBLIES* s Required by the Provisions of the ASME Code, Section 111, Division I Pg. I of 2 1. Fabricated and certified by TAYLOR FORGE ENGINEERED SYSTEMS, INC., 208 N. IRON STREET, PAOLA, KANSAS 66071 (nane and address of NPT Ceule Holder 2. Fabricated for SGT OCONEE P.O. 817 SENECA, S.C. 29679*a- Sod a )3. Location of Installation DUKE POWER-COMPANY SGT OCONEE NUCLEAR STATION 155 E PICKENS HIGHVWAY SENECA, S.C. 29672 (mee and address of Pchaser)4. Type: 806050-IF -806050-1 Di R14 -_ _ 2004 (Cerl Hds serial no.) (CR1N) (drawing no) (Natl Bd.no.) (year buift)5. ASME Code, Section IlIl, Division 1: 1989 1 N-474-2 (edilion) (addenda date) (das) (Code Case no.)6. Shop hydrostatic test 3200 Psi at 70 IF (if performed)

7. Description of piping RCS HOT LEG 145 DEGREE ELBOW 8. Certificate Holders' Data Reports properly identified and assigned by commissioned inspectors have been furnished for the following items of this report 9. Remarks: OCONEE STEAM GENERATOR REPLACEMENT PROJECT CERTIFICATE OF SHOP COMPLIANCE We certify that the statements made in this report are correct and that the fabrication of the described piping subassembly conforms to the rules for construction of the ASME Code, Section IlIl, Division 1.NPT Certificate of Authorization No. N-1937 expires November25 , 2004.Date 3 Name Taylor Forge Engineered Systems, Inc. Signed ____(NPT cerlificate Hoder) (aliorized represent)v CERTIFICATE-OF SHOP INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Kansas and employed by HSB CT , of Hartford.

CT , have inspected the piping subassembly described in this Data Report on 3 and state that to te best of my knowledge and belief, the Certificate Holder has fabricated this piping subassembly in accordance with the ASME Code, Section IlIl, Division 1.By signing this certificate neither the inspector nor " employer makes any wan' ty, e ressed or implied, concerning the piping subassembly described!in this Data Report Furthermore, neither the inse tor no s mployer shall e liabl in any manner for any personal injury or property damage or a loss of any kind arising from or connected wi Date .5 3/1 /10 Signed om ssionsB /2v q 9 F 7/ .touzed Nuclear InspeMt / (Natil. Bd. (it endorsement state or prev. Andno.)* Supplemental information in form of lists, sketches, or drawings may be used p idew 1 size is 8 %A x 11, (2) information in items 1 through 4 on this Data Report is included on each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form.Pmie. 3 oF t4 1F:'6rjC r=-Lbe,-j Z-S) ~ I FORM NPP-1 (Back -Pg. 2 of .2 )Certificate Holder's Serial No. 806050 -1F 0. Description of field fabrication I1. Pneu., hydro., or comb. test pressure psi at temp.IF (if performed) CERTIFICATE OF FIELD FABRICATION COMPLIANCE We certify that the statements on this report are correct and that the field fabrication of the described piping subassembly conforms with the rules for construction of the ASME Code, Section 1I1, Division 1.NPT Certificate of Authorization No.Expires Date Name-Signed (Cerfiricate Holderi lautfivrized reoresentafive) CERTIFICATE OF FIELD FABRICATION INSPECTION I, th- mndersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of and employed by of , have compared the statements in this Data Report with the described piping subassembly and state that parts referred to as data items , not included in the Certificate of Shop Inspection, have been inspected by me on , and thai to the best of my knowledge and belief, the Certificate Holder has fabricated this piping subassembly in accordance with the ASME Code, Section III, Division 1.By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the piping subassembly described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Date Signed Commissions MAI-eAm M.sbo 1-sed%{Natn BDA Fr.- eno n stale we Dv -an noI Date-SignedCommission re .s T-L=Ue._ He~ C FORM NIS-2 OWNER'S REPW r R REPAIRS OR REPLACEMENTS As Required By The Pros.. ns Of The ASME Code Section Xi 1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 1.a Date 09/22/04 Sheet 1 of 2 2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 2a. Unit r 1 r3 3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date iWA Shared (specify Units __ _ _ _ _ _3a. Work Order # 98532391 Repair Organization Job #3b. NSM or MM # ON-23086 AM4 WP 23067A 4. Identification of System Reactor Coolant Class 1 5. (a) Applicable Construction Code ASME III NB 1989 Edition N/A Addenda, No Addenda /Code Cases N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)

6. Identification of Components Repai red or Replaced and Replacement Components Column 1 Column 2 Column 3 column 4 Column 5 Col. 6 Column 7 Column 8 National ASME Code Manufacturer Board Other Year Repaired, Replaced, Stamped (yes Name of Component Name Of ManUfcturer Serial Number Number Mdentlffoatlon su R.- )of Ro_ _ Repaired r. No r Replaced r Yes A Piping Duke Power Company W/A N/A N/A Sep-74 r ReplacementY r Repaired F No r Replacedr e B r Replacement

_ Yes r Repaired r No r Replaced r Yes C r Replacement .Repaired r No F Replaced D ______ _ _Replacement F Repaired r No F Replaced r Yes E r Replacement F Repaired F No F Replaced r Yes F _ _ Replacement Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or draMngs maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets Is recorded at the top of this form.V 7. Description of Work Re-install reactor coolant piping for SAG 2A.8. Test Conducted: r Hydrostatic r Pneumatic W Nominal Operating Pressure r Other r Exempt Page 2 of 2 (Pressure _ _ psig Pressure _ _ psig Pressure _ _ _psig Test Temp OF Test Temp OF Test Temp _ _ OF 9. Remark: Existina reactor coolant piping had to be removed to allow removal of old SG and Installation of the new 2A steam generator. This NIS-2 covers the welding for re-Installing this hot leg piping. Applied Code Case N-416-1.(Applicable Manufacturers Data Records to be Attached)CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xi.Type Code Symbol Stamp NWA Certificate of Authorization No. -5 &p -Expiration Date N/A Signed ks I[42 Date c /Z /' G CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commision issued by the National Board of Boiler and essure Vessel Inspectors and the State or Providence of -) N J -and employed by have inspected the components described in this Owners Report during the period <:2=3--0 to I .; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection. A)-AO- Co11410 (rMmmissions no , I--rpw- Rm -- n-a -D nsct s+/- ignature Date 9 hi gX& jowevs no _I National Board, State, Providence and Endorsements Page 2 of 2 r C FORM NIS-2 OWNER'S REPO -JR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section Xl I 1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 1.a Date 09/22/04 Sheet 1 of 2 2a. Unit r I 1P 2 r3 r Shared (specify Units 3a. Work Order # 98532393 3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date WA Repair Organization Job #3b. NSM or MM # ON-23086 AM4 WP 23067B 4. Identification of System Reactor Coolant Class 1 5.(a)ApplicableConstructionCode ASMEIIINB 1989 Edition _UA AddendaNoAddenda

/Code Cases N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)

6. Identification of Components Repaired or Replaced and Replacement Components Column i Column 2 Column 3 Column 4 Column 5 1. Col. 6 Column 7 Column 8 o- m netMnacu National ASME Code Manufacturer Board Other Year Repaired.

Replaced, Stamped (vea Name of component Name of Manufacturer Serial Number Number Identification Built or Replacement or no), iv Repaired W No r Replaced r Yes A Piping Duke Power Company N/A N/A N/A 1974 r RepIacement r Repaired r No r Replaced r Yes B __ Replacement __ Repaired r No r Replaced r Yes C r Replacement r Repaired r No F Replaced F Yes D I. Replacement r Repaired r No rReplaced E r Replacement rRepaired r No r Replaced r Yes F r Replacement Page 1 of 2 --I i Forrn NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Re-install reactor coolant pIping for SG 2B.8. Test Conducted: r Hydrostatic r Pneumatic P Nominal Operating Pressure F Other [ Exempt Page 2 of 2 (Pressure _ _ psig Pressure _ _ psig Pressure psig Test Temp _ _ OF Test Temp _ _ OF Test Temp _ OF 9. Remark. Existing reactor coolant'piping had to be removed to allow removal of old SG and Installation of the new 2B steam generator. This NIS-2 covers the welding for re-installing this hot leg pipIng. Applied Coide Case N-416-1.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are correct and this repair or replacement conforms to tho rules of the ASME Code, Section Xl.Type Code Symbol Stamp NIA Certificate of Authorization No. #/A S KS Expiration Date NIA Signed _ ___ _ Datee .CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commision issued by the National Board of Boiler and Pr &sure Vessel Inspectors and the State or Providence of H and employed by 13C have inspected the components described in this Owner's Report during the periodis-- °Y to -/- o ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector norbhis employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions A V0 ?S3. A. L Ins~ecor-'s~ignature National Board, State, Providence and Endorsements Date q-p)q Page 2 of 2 C-r-FORM NIS-2 OWNER'S REPOi k A REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI fn.1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 1.a Date 09/22/04 Sheet 1 of 2 2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 2a. Unit (r 1 F 2 r 3 F Shared (specify Units 3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A 3a. Work Order # 98530942 Repair Organization Job #3b. NSM or MM # ON-23086 AM3 WP 23075A 4. Identification of System Emergency Feedwater Class 2 5. (a) Applicable Construction Code ASME IlI NC 1989 Edition N/A Addenda, No Addenda /Code Cases WA (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)

6. Identification of Components Repaired or Replaced and Re fcement Components_

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _Column I , Column 2 Column3 Column 4um5 -Col .6 Column 7 Column 8 Manufa-cturer Board IOther IYear lRepalred, Replaced, Stamped (ves-NJame Wm Conponeni Name of Manutacturer Seriai Number Number IdentificatIon Built or Replacement or no)x7 Repaired F No r Replaced F Y A Piping Duke Power Company WA NWA N/A 1974 r Replacement r Repalred rNo r Replaced r Yes B rReplacement r Repalred r No r Replaced r Yes C r Replacement F Repaired F No r Replaced F Y D r Replacement r Repaired F No rReplaced r Yes E r Replacement r Repalred F No r Replaced F Yes F rReplacement Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information in items 1 through 6 on this report is included on each..sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Install emergency feedwater Pl&ina for SG 2A.8. Test Conducted: r Hydrostatic r Pneumatic Pr Nominal Operating Pressure r Other r Exempt Page 2 of 2 Pressure _ _ psig Pressure _psig Pressure psig Test Temp _ _ OF.Test Temp _ _ OF Test Temp OF 9. Remarlu Existing emergency feedwater piping had to be removed to allow Installation of the 2A isteam generator. I h15 NIIS-2 Covers mte welodinu for re-Instalsnun mtis Pouinu.Applied Code Case N.416-1.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made In the report are conrect and this repair or replacement conforms to the rules of the ASME Code, Section Xl.Type Code Symbol Stamp NWA Certificate of Authorization No. ,/A 6&f- Ad 51<K<5C Expiration Date N/A Signed ," Y/A' ° Date c ZZ /5 4 C CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commislon issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of ._ and employed by I s et C have Inspected the components described in this Owner's Report during the period7{;ic.Y to '.h7L and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descrited in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Comission A idd Y3. A) Z Inspeckfrs Signature Date National Board, State, Providence and Endorsements Page 2 of 2 r FORM NIS-2 OWNER'S REPC by )R REPAIRS OR REPLACEMENTS As Required By The Prov. -as Of The ASME Code Section Xl_1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 l.a Date _0912204 Sheet 1 of 2 2a. Unit F 1 r3 r Shared (specify Units 3a. Work Order # 98530942.3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A Repair Organization Job #3b. NSM or MM # ON-23086 AM3 WP23075A 4. Identification of System Emergency Feedwater Class 2 5. (a) Applicable Construction Code ASME III NC 1989 Edition W/A Addenda, No Addenda _Code Cases N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.):
6. Identification of Components Repaired or Replaced and Rep acement Components Column 1 Column 2 Column 3 Column4 Column 5 Col. u 67 Column 8 Manufacturer Board Other Year Repalred, Replaced, Stamped (yes Name of Component Name of Manufacturer Serial Number dent!f!cat!on Bu!!t or Replacement orno._P Repaired Wo No Hanger/Support FrReplaced F yes A 2-03-148HA-H2B Duke Power Company N/A WA N/A 1974 r Replacement
Repalred W No Hanger/Support r Replaced r Yes B 2-03-1480A-H1B Duke Power Company N/A A N/A 1974 r Replacement W Repaired r No Hanger/Support r Replaced r Yes C 2-03-1480A-H6106 Duke Power Company N/A NA N/A 1974 r Replacement Wo Repaired W No Hanger/Support r Replaced r Yes D 2-03.1480A-H6107 Duke Power Company N/A N/A WA 1974 r- Replacement W Repaired W No Hanger/Support r Replaced r Yes E 2-03-1480A-H6109 Duke PowerCompany N/AN/A A 1974 r Replacement

_ Repalred r No r Replaced r Yes F r_ Replacement Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 12 in. x 11 in. (2) Information in items 1 through e, on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Remove/reolace supports for removal of Interferences for SG 2A removal.8. Test Conducted: r Hydrostatic r Pneumatic r Nominal Operating Pressure r Other 1V Exempt Sheet 2 of 2 Pressure _ _ psig Pressure '_ psig Pressure psig Test Temp 'F Test Temp OF Test Temp _ _ OF 9. Remark: Hangers were removed for the removal of the 2A SG and replaced after Installation of the new replacement steam generator.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rulbs of the ASME Code, Section Xl.Type Code Symbol Stamp NIA Certificateof Authorization No -5W F S , Expiration Date NIA Signed 1 Date / Z iS __ eSS q0 ............................................... -..... A___CERTIFICATE OF INSEFVICE INSPECTION 1, the undersigned, holding a valid commision Issued by the Nalional Board of Boiler and Pre sure Vessel Inspectors and the State or Providence of No _ and employed by have inspected the components descr bed In this Owners Report during the period to 7^~i ;and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employ6r makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection. -6fkkL 4 Au Cnmmissinns MdD XS3. U I....... ...'inIspetor's Signature Date ---DV National Board, State, Providence and Endorsements Page 2 of 2 (FORM NIS-2 OWNER'S REPO(C 3R REPAIRS OR REPLACEMENTS As Required By The Prov is Of The ASME Code Section Xl C1 1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 1.a Date 09/22/04 Sheet 1 of 2 2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 2a. Unit r 1 WI2 r3 r Shared (specify Units 3a. Work Order# 98530949 Repair Organization Job #3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp NWA Authorization No. NIA Expiration Date NWA 3b. NSM or MM # ON-23086 AM3 WP 23075B 4. Identification of System Emergency Feedwater* ~ Class 2 5. (a) Applicable Construction Code ASME IlI NC 1989 Edition N/A Addenda, No Addenda /Code Cases N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)

6. Identification of Components Repred or Relaced and Re ment Components Column 1 Column 2 Column 3 Column 4 Column 5 Col.6 Column 7 Column 8 NationalASME Code Manufacturer Board Other Year Repalred, Replaced, Stamped (yes Name of Component Name of Manufacturer Serial Number N Numhpr WdentU.:f1aon DUll or Repiacement or no)-Repaired F No A PipIng Duke Power Company N/A N/A N/A 1974 r Replacement Ce.r Repaired F No FReplaced Ye B r Replacement rYes_ Repaired r No r Replaced r Yes c r Replacement r RepaIred r No r Replacedr e D r Replacement r Repalred r No rF Replaced r Yes E i Replacement r Repalred r No r Replaced r Yes F ____ __r Replacement Page 1 of 2 Form NIS-2 (Back)Page 2 of 2 NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information in items 1 through 6 on this report Is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Install emergency feedwater pining for SG 2B.8. Test Conducted:

F Hydrostatic F Pneumatic 7 Nominal Operating Pressure F Other F Exempt Pressure psig Test Temp OF Pressure _ psig Test Temp OF Pressure psig Test Temp OF 9. Remarke Existing emergency feedwater 1lping had to be removed to allow Installation of the 2B steam generator. This NIS-2 covers the welding for re-installing this piping.Applied Code Case N-416-1.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.Type Code Symbol Stamp N/A Certificate of AuthorizatioN N/A Expiration Date N/A Signed_ __ Date q ZZ 04'-L -I_ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _Mm CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commision issued by the Nalional Board of Boiler and Pressure Vessel Inspectors and the State or Providence of ( .., and employed by -Er have inspected the components described in this Owner's Report during the period to _~ _ ;andstate that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Cods, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising or connected with this inspection. Commissions iN3, A K In~ pec-G Signature National Board, State, Providence and Endorsements --I Date 9 by I Page 2 of 2 f FORM NIS-2 OWNER'S REPC -OR REPAIRS OR REPLACEMENTS As Required By The Prow. us Of The ASME Code Section Xi 1. Owner -2Duke Power Companyh S -- N --Address 526 S. Church Street, Charlotte, NC 28201,-1006 l.a __te 09/22/04 Sheet 1 of 2 2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 2a. Unit r 1 1v 2 r 3 r Shared (specify Units _3a. Work Order # 98530949 3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A Repair Organization Job #3b. NSM or MM # ON-23086 AM3 WP23075B 4. Identification of System Emeraencv Feedwater Class 2 5. (a) Applicable Construction Code ASME III NC 1989 Edition NL/A Addenda, No Addenda /Code Cases NLA (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)

6. Identification of Components Repaired or Replaced and Replacement Components Column 1 Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8 NationalASME Code Manufacturer Board Other Year Repaired, Replaced, Stamped (yes Name of Component Name of Manufacturer Serial Number Number A.cntlflcatIon Buiit or Replacement or no)i Repaired iv No Hanger/Support F Replaced r Yes A 2-03A-1480A-H3A Duke Power Company N/A N/A NWA 1974 r Replacement P Repaired iv No Hanger/Support .r Replaced r Yes B 2-03A-1480A-H6263 Duke Power Company N/A N/A NWA 1974 r Replacement

.eRepalred r No Hanger/Support rF Replaced FYes C 2-03A-148OA-H6111 Duke Power Company N/A N/A N/A 1974 r Replacement r Repaired FNo r Replaced r Yes D r Replacement r Repaired r No r Replaced r Yes E lr Replacement

l. Repaired r No Fr Replaced I Yes F Fr Replacement Page 1 of 2

--- I Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size Is 8 1/2 In. x 11 in. (2) Information in items 1 through 6 on this report is Included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Remove/rePlace supoorts for removal of Interferences for SG 2B removal.8. Test Conducted: r Hydrostatic r Pneumatic r Nominal Operating Pressure r Other P Exempt Sheet 2 of 2 (Pressure _ _ psig Pressure psig Pressure _ _ psig Test Temp _ _ OF Test Temp OF Test Temp OF 9. Remark. Hangers were removed for the removal of the 2B SG and replaced after Installation of the new replacement steam generator.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the'ASME Code, Section Xl.Type Code Symbol Stamp NI/A Certificate of Authorization No. NI , Z J Expiration Date N/A&E4 Ca. E ,EA Signed g/ A/ Date '-I/ z-e o6'I-- CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commision issued by the National Board of Boiler and assure Vessel Inspectors and the State or Providence of '1 .._ _ and employed by I? C X have Inspected the components desciibed in this Owner's Report during the period toI4~ I Tand state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. ktL GCommissions +JcV5 3. M I Inspeict4s Signature Date 3 l qU) 'National Board, State, Providence and Endorsements Pag 2 of 2 r-FORM NIS-2 OWNER'S r U 3T FOR REPAIRS OR REPLACEMENTS As Required By The * .4trislons Of The ASME Code Section Xi f 1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-logo

2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 1.a Date 09/22/04 Sheet I of 2 2a. Unit r 1 Pr2 r-3 F Shared (specify Units 3a. Work Order# 98516356 3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A Repair Organization Job #3b. NSM or MM # ON-23086 AM1 WP 23080A 4. Identification of System _Main Steam Class 2 5. (a) Applicable Construction Code ASME III NC 1989 Edition N/A Addenda, No Addenda /Code Cases N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)
6. Identification of Components Rep ired or Replaced and Replacement Components

_______Column 1 Column 2 C Column3 C 4 Column 5 Coi. 6 Column 7 Column 8 National ASE Coe Manufacturer Board Other Year Repaired, Replaced, Stamped (yes Name of Compon ..... .--. e : Nae ur ^r'a '..t. 1b -- eon ova .. CPI Ivlululayl ial. IV.IIWVIMulit Wt nupmVu0 I ut11=111 WI , 1- Repaired P No r Replaced r Yes A Piping Duke Power Company N/A N/A N/A 1974 r Replacement r Repalred r No r Replaced r Yes B r Replacement rYes r Repalred r No r Replaced r Yes C FrReplacement r Repalred r No r Replaced r Yes D r Replacement r Repaired r No F Replaced r Yes E rP Replacement F- Repaired rF No F ReplacedrYe F r- Replacement Page 1 of 2 -l- EMNNMMOI Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work install main steam plplng for SG 2A.Page 2 of 2 (8. Test Conducted: f- Hydrostatic r Pneumatic W Nominal Operating Pressure r Other r Exempt: Pressure psig Pressure psig Pressure psig Test Temp _ _ 'F Test Temp _ _ 0 F Test Temp °F 9. Remarks Existing main steam PlPlng had to be removed Ito allow Installation of the 2A steam generator. This NIS-2 covers the welding for re-Installing this plping.Aonlied Code Case N-416-1.(Applicable Manufacturers Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correci and this repair or replacement conforms to the nrles of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization No A Expiration Date NIA Signed H i ,/ 2/ E Date c / z 1o I CERTIFICATE OF INSERVICEE INSPECTION 1, the undersigned, holding a valid commision ipsjied by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of -MeJ_ and employed by -S EELS have Inspected the components described In this Owners Report during the period 2z /to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Cotde, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. -4A1&k Lv% Commissions Ma T 53, A. I------ --- ------Irnpecftor Signature National Board, State, Providence and Endorsements Date 9 n2Ying Page 2 of 2 f FORM NIS-2 OWNER'S REPC i )R REPAIRS OR REPLACEM'1ENTS As Required By The Provi- as Of The ASME Code Section Xi.(1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 1.a Uate _0.Zrc0U4 Sheet 1 of 4 2a. Unit r I PW 2 r3 r Shared (specify Units _3a. Work Order # 98516356 3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201.1006 Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A Repair Organization Job #3b. NSM or MM # ON-23086 AMI WP23080A 4. Identification of System Main Steam Class 2_5. (a) Applicable Construction Code ASME Ill NC 1989 Edition N/A Addenda, No Addenda /Code Cases N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class. MC and cc and their supports.)

IdAntificatinn of Componants RAnAlrAd or RAnlaned and Replacement CnmnonAnts 6 Column 1 Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Coumn _I ational ASME Code Manufacturer Board Other Year Repaired, Replaced, Stamped (yes Name of Coinonent Name of Manufacturer Serial Number Number Mdent~f-tion Bu!!t o Rep'aem-ents or -o)wo Repaired Pr No Hanger/Support r Replaced r Yes A 2-O1A-0-1481A-H1B Duke Power Company N/A N/A N/A 1973 r Replacement P Repaired 1P No Hanger/Support r Replaced r Yes B 2-O1A-0-1481A-H7B Duke Power Company N/A N/A N/A 1973 r Replacement Po Repaired P No Hanger/Support r Replaced r Yes C 2-OIA-0-1481A-H3B Duke Power Company N/A N/A N/A 1973 r Replacement __ Repaired 17 No Hanger/Support rReplaced rYes D 2-01A-0-1480A-H9B Duke Power Company NWA N/A NIA 1973 r Replacement __ Repaired Pr No Hanger/Support rReplaced r Yes E 2-O1A-0-1481B-H2B Duke Power Company N/A N/A N/A 1973 r Replacement W Repaired 1P No Hanger/Support r Replaced r Yes F 2-01A-0-1481B-H8B Duke Power Company N/A N/A N/A 1973 r Replacement Page 1 of 4 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information in items 1 through 43 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is Sheet 2 of ' -4 this form.7. Description of Work Removelreolace supoorts for removal of Interferences for SG 2A removal.8. Test Conducted: r Hydrostatic r Pneumatic r Nominal Operating Pressure r Other 1v Exempt Sheet 2 of 4 Pressure _ _ psig Pressure psig Pressure _ _ psig Test Temp ..OF Test Temp : OF Test Temp _ OF 9. Remarkz Hangers were removed/Dinned for the removal olf the 2A SG and replacedfunpinned after Installation of the new replacement steam cenerator.

(Applicable Manufacturer's Dala Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xi.Type Code Symbol Stamp N/A Page 1 of 4 Certificate of Authorization No. N &EAA SeVIOg. Expiration Date N/A Signed I , / Date -9 /b'CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commision issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of A. C ._ and employed by have inspected the components described in this Owner's Report during the period to -; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of anry kind arising from or connected with this inspection.

_gn, Commissions / Y!5S3 1 A) I Signature Nalional Board, Sfate, Providence and Endorsemenis Date 9 ? wM Page 2 of 4 (F Forn. .3-2 (Back)dk~* '1 .- A 0.we ul 1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 l.a Date _09/22/0j4. Sheet 3 -of 4 2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 2a. Unit r 1 F.2 r3 r Shared (specify Units 3a. Work Order# 98516356 Repair Organization Job #3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A 3b. NSM or MM # ON-23086 AM1 WP23080A 4. Identification of System Main Steam Class 2 5. (a) Applicable Construction Code ASME III NC 1989 Edition N/A Addenda, No Addenda ICode Cases N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class. MC and cc and their supports.)

6. Identification of Components Repared or Replaced and Rep ment Components Columni1 Column 2 Column 3 _olmn_ Column 5 Col. 6 Column 7 Column 8 j National I -Code Manuacturer Board Other Year Repaired, Replaced, Stamped (yes Name of Component Name of Manufacturer Serial Number Number Identification BuIlt or Replacemnent Cor -f)1v Repaired F No Hanger/Support r Replaced r Yes G 2-O1A-0-1481A-H1OB Duke Power Company N/A N/A N/A 1973 r Replacement F Repaired i7 No Hanger/Support r Replaced r Yes H 2-01A-0-1481A-H6B Duke Power Company N/A N/A N/A 1973 r Replacement

_ ___ Repaired p No Hanger/Support r Replaced r Yes 2-01A-0-1481A-H11B Duke Power Company N/A N/A N/A 1973 r Replacement r Repalred r No rReplaced r Yes r Replacement F Repaired r No r Replaced rYes r Replacement r Repaired r No r Replaced r Yes rF Replacement Form NIS-2 (Back)NOTE: Supplemental sheets In form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information In items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Remove/replace supports for removal of Interferences for SG 2A removal.8. Test Conducted: r Hydrostatic r Pneumatic -Nominal Operating Pressure r Other F Exempt Sheet 4 of 4 Pressure _ _ psig Pressure psig Pressure psig Test Temp _ IF Test Temp °F Test Temp OF 9. Remark: Hangers were removed/nlnned for the removal of the 2A SG and replacedfunpinned after Installation of the new replacement steam venerator.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section XI.Type Code Symbol Stamp NWA Certificate of Authorization No. N/ 5 I IExpiration Date NIA Signed IE I Date q a' / 0 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commision iss ed by the National Board of Boiler and Prps re Ve 5 I Inspectors and the State or Providence of _ and employed by f El have inspected the components described In this Owners Report during the period 29~s;and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Ownees Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arisin~g fron or connected with this inspection. A, , .)A CnmmissioinnsQt \ 53, I. 7 Ins aeos~ignature pate q-aq National Board, State, Providence and Endorsements Page 4 of 4 f FORM NIS-2 OWNER'S REr (.- FOR REPAIRS OR REPLACEMENTS As Required By The Pro. .ons Of The ASME Code Section Xi-IW 1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 1.a Date 09/22/04 Sheet 1 of 2 2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 2a. Unit r 1 r3 r Shared (specify Units 3a. Work Order # 98516357_ .3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp NWA Authorization No. WA Expiration Date NWA Repair Organization Job #3b. NSM or MM # ON-23086 AMI WP 23080B 4. Identification of System Main Steam Class 2 5. (a) Applicable Construction Code ASME liI NC 1989. Edition _ULA -Addenda, No Addenda iCode Cases N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)

6. Identification of Components Rep ired or Replaced and Replacement Components Column I Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8 Nationa ASME Code Manufacturer Board Other Year Repaired, Replaced, Stamped (yes NameofComponent Name of Manuftrer SerialNumber IT Number adentification Bulit or Replacement or no)1NN Repaired ASM N Co rReplaced r Yes A Piping Duke Power Company N/A WA N/A 1974 r Replacement r RepaIred No r Replaced r Yes B r Replacement

__Yes r Repalred r No r Replaced r' Yes C r Replacement r Repalred r No r Replaced F Y D -Replacement r Repaired No rReplaced F Yes E r Replacement r Repaired F No r Replaced r Yes F _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Replacem ent Page 1f 12 Form NIS-2 (Back)NOTE. Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information in items 1 through l; on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Install main steam Piping for SG 2B.8. Test Conducted: Hydrostatic r Pneumatic 1 Nominal Operating Pressure r Other r Exempt Page 2 of 2 Pressure _ _ psig Pressure _ _ psig Pressure _ _ _ peig Test Temp OF Test Temp .F Test Temp _ OF 9. Remark* ExIsting feedwater DDllnO had to be removed to Ellow InstallatIon of the 2B steam generator. This NIS-2 covers the weldina for re-Installlna this PiDing.Applied Code Case V-416-1.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization No. SAR k& k SeI\tb .Expiration Date N/A Signed Z/2Z st Date hatM M CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commislon issued by the National Board of Boiler and trerhureYessel Inspectors and the State or Providence of -N C- _ and employed by & 5-k3Ca have inspected the components described in this Owner's Report during the period 9-20V to /i° and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employor makes any warranty, expressed or implied, concerning the examinations and corrective measures described ii this Owners ReporL Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection. _A'VCommissions na A 53 -) I 2: InspectioKSIgnature Date National Board, State, Providence and Endorsements Pago 2 of 2 f f-FORM NIS-2 OWNER'F £ ORT FOR REPAIRS OR REPLACEMENTS As Required ByTh. ovislons Of The ASME Code Section Xl (1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 1.a Date 09/2204 Sheet --1 of 2 2a. Unit r 1 P2 F3 r Shared (specify Units)3a. Work Order # 98516357 Repair Organization Job #3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp NIA Authorization No. N/A Expiration Date N/A 3b. NSM or MM # ON-23086 AMI WP23080B 4. Identification of System MaIn Steam Class 2 5. (a) Applicable Construction Code ASME IlIl NC 1989 Edition N/A Addenda, No Addenda /Code Cases N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)

Identification of CnmnnnAntR Ranairarl nr Rnlanarl Anrd Mantamant r 6.Column 1 Column 2 Column3 Coln4 Column5 1Col.6 Column7 l Column 8 I _ IASME Code Manufacturer Board Other Year Repaired, Replaced, Stamped (yes Name of Component Name of ManufSturer Serla! Number Nu.mer identification Buiit or Replacement or no)W Repaired rv No Hanger/Support r Replaced F Yes A 2-OIA-0-1480A-H7A Duke Power Company N/A N/A N/A 1974 r Replacement iv Repaired 1v No Hanger/Support r Replaced r Yes B 2-OIA-0-1480A-H1A Duke Power Compan N/A N/A N/A 1974 r Replacement id Repaired P7 No Hanger/Support r Replaced r Yes C 2-O1A-0-1481A-H6A Duke Power Company N/A N/A NA 1974 r Replacement 1P Repaired 17 No Hanger/Support r Replaced r Yes D 2-O1A-0-1481A-H9A Duke Power Company N/A N/A N/A 1974 r Replacement 17 Repaired 1; No Hanger/Support r Replaced r Yes E 2-01A-0-1481A-H3A Duke Power Company N/A N/A NA 1974 r Replacement.v Repaired P' No Hanger/Support r Replaced r Yes F 2-01A-0-1481B-H2A Duke Power Company N/A N/A N/A 1974 r Replacement Page 1 of 2 -I Form hIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information in items 1 through 6 on this report Is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Remove/replace supports for removal of Interferences for SG 2B removal.Sheet 2 of 2 8. Test Conducted: F- Hydrostatic F Pneumatic r Nominal Operating Pressure r Other be Exempt Pressure _ psig Pressure psig Pressure psig Test Temp ..'F Test Temp .."F Test Temp "F 9. Remarku Hancers were removed/pInned for the removal of the 2B SG and replacedfunolnned after Installation of the new replacement steam venerator.(Applicable Manufacturers Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xi.Type Code Symbol Stamp N/A Cerlificateof Authorization No. WA !5 e-ft-k se^. cr- Expiration Date WVA Signed &I K A E D ate _ _ _ _ _ _ _ _ _CERTIFICATE OF INSERVICIE-INSPECTION 1, the undersigned, holding a valid commision isued by the National Board of Boiler and Pressure-Yessel Inspectors and the State or Providence of / and employed by

  • Qt -have inspected the components described in this Owner's Report dunng the period -7_oy tog D s 'and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

k&i4A Commissions 63C 535 a, J-Inspector'? Signature Date , C a 0 t°National Board, State, Providence and Endorsements Page 2 of 2) -r FORM NIS-2 OWNER'S REPr -')R REPAIRS OR REPLACEMENTS As Required By The Pros ".a Of The ASME Code Section Xl IC 1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 1.a Date _09/22/04 Sheet 1 of 2 2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 2a. Unit r 1 Pr2 r3 r Shared (specify Units 3a. Work Order # 98516357 Repair Organization Job #3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp NIA Authorization No. N/A Expiration Date N/A 3b. NSM or MM # ON-23086 AMI WP23080B 4. Identification of System Main Steam Class 2 5. (a) Applicable Construction Code ASME III NC 1989 Edition N/A Addenda, No Addenda /Code Cases WA (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)

6. Identification of Compoents Repaired or Replaced and Replcement Components-I Column 1I Column 2 I Column 3 Colmn Column 5 Col. 6 Column 7 jColumn 8 I _ NationalSIAME Code Manufacturer Board Other Year Repaired, Replaced, Stamped (yes Name of Component Name of Manufacturer Serial Number Number Identification Ruiltl r p I or no)Pv Repaired Pr No Hanger/Support r Replaced r Yes A 2-OIA-0-14SA-H8A l Duke Power Company l NWA WA A 1974 r Replacement Pv Repaired R No r Replaced Yes B r Replacement Po Repaired P7 No r Replaced rYes C r Replacement F Repaired Pr No 11-Replaced Y~es D r Replacement P RepaIred FP, No F- Replaced Y ,es E r Replacement P Repaired PN r Replaced F Yes F r. Replacement Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets In form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information in items 1 through 6 on this report Is included on each sheet, and (3) each sheet is numbered and the number of sheets Is recorded at the top of --this form.7. Description of Work Remove/replace supports for removal of Interferences for SG 2B removal.Sheet 2 of 2 8. Test Conducted:

r Hydrostatic r Pneumatic F Nominal Operating Pressure r Other 17 Exempt Pressure _ psig Pressure -_ psig Pressure _ psig Test Temp _ _ OF Test Temp OF Test Temp OF 9. Remark. Hangers were removed/linned for the removal of the 26 SG and replacedfunpinned after Installation of the new replacement steam generator.(Applicable Manufacturer's Dala Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization No. 15/6-\ is p.1ev r Expiration Date N/A Signed }'-4 A-_ Date e7 e/oet CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commision issued by the National Board of Boiler and Pressre Vessel Inspectors and the State or Providence of -C ___ and employed by h W 1 C have inspected the components described in this Owners Report during the period270 to FJq ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owners Report in accordance with the requirements of the ASME Coce, Section XI.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, conceming the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any dnd arising from or connected with this inspection. Jo.-ins -- -Ban 8 it l @@8Vffi he .46rp&9s Signature Date -f e.0_ )National Board, State, Providence and Endorsement, Page 2 of 2 FORM NIS-2 OWNER'S r id IT FOR REPAIRS OR REPLACEMENTS As Required By The, r.vIslons Of The ASME Code Section Xl C-1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 L.a Date 09/22/04 Sheet 1 of 2 2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 2a. Unit r I r72 F3 r Shared (specify Units _3a. Work Order # 98516899 3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A_ _ .Repair Organization Job #3b. NSM or MM # ON-23086 AM2 WP 23085A 4. Identification of System Feedwater Class 2 5. (a) Applicable Construction Code ASME III NC 1989 Edition N/A Addenda, No Addenda /Code Cases N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)

6. Identification of Components Rep ired or Replaced and Rep acement Components
-Column 1 Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8 National A Code Manufacturer Board Other Year Repaired, Replaced, Stamped (yes ia 01 1pumici.t Nami 0i mo"Wanu;aurer Sab Number blaemet AM Code PO Repaired fv No r Replaced r Yes A Piping Duke Power Company N/A N/A N/A 1974 r Replacement r Repaired r No r Replaced r Yes B r Replacement r Repalred r No r Replaced r Yes C r Replacement r Repaired F No r Replaced r Yes D rReplacement r Repaired F No r Replaced r Yes E _ Replacement F Repaired r No F Replaced r Yes F _ _ Replacement Page 1 of 2 Form NIIS-2 (Back)Page 2 of 2 NOTE
Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 1 1 in. (2) Information in items 1 through 13 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Install feedwater piolna for SG 2A.8. Test Conducted:

F Hydrostatic F Pneumatic P Nominal Operating Pressure r Other I Exempt Pressure psig Test Temp .F Pressure psig Test Temp OF Pressure psig Test Temp OF 9. Remark: Existing feedwater ololna had to be removed to allow Installation of the 2A steam generator. This NIS-2 covers the weldina for re-installing this ollnag.Apnlied Code Case N-416-1.(Applicable Manufacturer's Dalta Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the nules of the ASME Code, Section Xi.Type Code Symbol Stamp WiA Certificate of Authorization IV. NWA ; 5 b Expiration Date WA Signed C Date °?/CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commision i6sued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of -__- and employed by iv S3C-'have inspected the components described in this Owner's Report during the period zV^79 to i> L. and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. commissions __J tS3, A)InspeC o's Signature National Board, State, Providence and Endorsements Date .91 ftI bL Page 2 of 2 C FORM NIS-2 OWNER'S RF £- FOR REPAIRS OR REPLACEMENTS As Required By The Pi, Aions Of The ASME Code Section Xi lo 1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 1.a Date .09122104 Sheet 1 of 2 2a. Unit r I 1; 2 r 3 -r Shared (specify Units 3a. Work Order # 98516899 Repair Organization Job #3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A 4. Identification of System Feedwater Class 2 3b. NSM or MM # ON-23086 AM2 WP23085A 5. (a) Applicable Construction Code ASME IlIl NC 1989 Edition N/A Addenda, No Lddenda Code Cases NWA (b) Applicable Edition of Section Xl Utilized for-Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)

Identification of Components Repaired or Replaced and Replacement Comnonanfi 6.I Column 1 Column 3 Columnt 34 Col. 6 Column 7 Column 8-National _ ASME Code.Manufacturer Board Other Year Repaired, Replaced, Stamped (yes Name of Component Name of Manuf cturer Ser!al Number Mumber r enf;fiion ium or Replacement or no).v Repaired Pr No Hanger/Support r Replaced rF Yes A 2-03-0-1480B-H6B Duke Power Company N/A NIA N/A 1974 r Replacement r Repalred r No rReplaced r Yes B r Replacement r Repalred r No r Replaced r Yes C r Replacement r Repaired r No rReplaced -Yes D FReplacement r Repalred r No F- ReplacedrYe E .Replacement r Yes F. Repaired r No Fr Replaced or Yes F r Replacement Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size Is 81/2 in. x 11 in. (2) Information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Secure/restraln supports for removal of Interferences for SG 2A removal.8. Test Conducted: r Hydrostatic r Pneumatic r Nominal Operating Pressure r Other 17 Exempt Sheet 2 of 2!Pressure psig Pressure ____psig Pressure _' Ipsig Test Temp OF Test Temp _ _ OF Test Temp .OF 9. Remark: Snubber was removed for the removal of the 2A SG and reinstalled after Installation of the new replacement steam generator.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization No. NWA 5 , Expiration Date N/A Signed / A / e Date 't 22/.6 CERTIFICATE OF INSERVICEE INSPECTION I, the undersigned, holding a valid commision issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of C .and employed by -have inspected the components described in this Owner's Report during the period .IDlO-4 to .*:Xer S, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of anY kind arising from or connected with this Inspection. °LO. e .Commissions CA-3(m C J0w Inspector's Vigtature Date 3 °0- O4 National Board, State, Providence and Endorsements Page 2 of 2 f C FORM1. NIS-2 OWNER'S REP( -JR REPAIRS OR REPLACEMENTS As Required By The Provi..-ns Of The ASME Code Section Xl ( 20-1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 1.a Date 09/22/04 Sheet 1 of 2 2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 2a. Unit F I W 2 r3 F-.Shared (specify Units 3a. Work Order # 98516911 Repair Organization Job #3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. NiA Expiration Date NIA 3b. NSM or MM # ON-23086 AM2 WP 23085B 4. Identification of System Feedwater Class 2 5. (a) Applicable Construction Code ASME Ill NC 1989 Edition NIA Addenda, No Addenda tCodeCases N/A (b) Applicable Edition of Section XI Utilized for Rep-airs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)

6. Identification of Components Repaired or Replaced and Re cment Corponents Column 1 Column 2 Column 3 -Column 4 Column 5 Col. 6 Column 7 Column 8_ Nationai -SECd Manufacturer Board Other Year Repaired, Replaced.

Stamped (yes tComponent me -t Number IdentificatIon Built or Replacement or no)P Repaired Pr No r Replaced r Yes A Piping Duke Power Company N/A N/A N/A 1974 r Replacement F- Repaired r No r Replaced r Yes B r Replacement r Repaired r No r Replaced r Yes CrReplacement r Repaired r No rReplaced r Yes D rReplacement r Repalred r No r Replaced r Yes E __ _Replacement r RepaIred F No r Replaced F Yes F r Replacement Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Install feedwater piping for SG 2B.8. Test Conducted: r Hydrostatic F Pneumatic 17 Nominal Operating Pressure r Other r Exempt Page 2 of 2 Pressure _ _psig Pressure psig Pressure _ _ -psig Test Temp ..OF Test Temp OF Test Temp OF 9. Remarl Existing feedwater olalna had to be removed to allow Installation of the 2B steam generator. This NIS-2 covers the welding for re-Installing this plplnq.Applied Code Case N-416-1.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.Type Code Symbol Stamp NWA Certificate of Authorization o pNA N A Expiration Date WA Signed_ Date CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commision Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of CA and employed by RSB- CT have inspected the components described in this Owner's Report during the period 2-1p-0 4 to 6-10 ^; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. _ _ _ _ __ Commissions AA '96 < po i am lnspector's~ithature National Board, State, Providence and Endorsement., Date 9-Qk3- as Page 2 of 2 FORM NIS-2 OWNER'S REPC f JR REPAIRS OR REPLACEMENTS As Required By The Provei is Of The ASME Code Section Xi A-1-I 1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Oconee Nuclear StatIon Address 7800 Rochester Hwy. Seneca, S.C. 29672 l.a Date 09/104 Sheet 1 of 2 2a. Unit r- 1 rv2 r3 F nShared (specify Units 3a. Work Order # 98516911 3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. W/A Expiration Date N/A 4. Identification of System Feedwater Class 2 -M Repair Organization Job #3b. NSM or MM # ON-23086 AM2 WP230858 5. (a) Applicable Construction Code ASME III NC 1989 Edition W/A Addenda, No Addenda /Code Cases N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)
6. Identification of Components Repired or Replacedand Re ment Components Column 1 Column 2 Columnl3 Column 4 Column 5 Col. 6 Column 7 Column 8 National ASME Code N Manufacturer Board Other Year Repaired, Replaced, Stamped (yesI Name of Component Name of Man___turer Serial Number Nu M ber Idertllfation Buit or Replacement or no)F1; Repaired F No Hanger/Support r Replaced r Yes A 2-03-0-1479A-H2A Duke Power Company N/A 1974 r Replacement r Repaired F No rReplaced re B r Replacement rRepalred r No r Replaced r Yes C r Replacement r Repalred r No r Replaced r Yes D FrReplacement r Repaired F No-~~ F Replaced Fe E r Replacement rRepalred r No , Replaced r Yes F 1 Replacement Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Remove/restore supports for removal of Interferences for SG 2B removalfreplacernent.
8. Test Conducted:

F Hydrostatic F Pneumatic r Nominal Operating Pressure F Other r7 Exempt Sheet 2 of 2 Pressure _ _ psig Pressure _ _psig Pressure _ _ psig Test Temp OF Test Temp OF Test Temp _ _ OF 9. Remark: Hanger was removed for the removal of the 2B SQG and reinstalled after Installation-of the new replacement steam generator.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization No NA 5 s4 Expiration Date NIA Signed Z/L em > t Date___________ CERTIFICATE OF INSERVICEi INSPECTION I, the undersigned, holding a valid commision issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of CA and employed by " 13 -CT have inspected the components described In this Owners Report during the period 4-O)- 04 to ^ and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Coxle, Section Xi.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a loss of any kind arising from o, cpnnected with this Inspection. .0. Commissions k (S A*<Inspector's 4griure National Board, State, Providence and Endorsement; Date_ 9- 2_ __Page 2 of 2 r'k FORMr Ni-2 OWNER'S RF ? FOR REPAIRS OR REPLACEMENTS As Required By The Pr.. ..Oons Of The ASME Code Section Xl i_1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 l.a Date 09/22/04 Sheet 1 of 2 2a. Unit r 1 1v2 r 3 -r Shared (specify Units _3a. Wnrk Ordar A 985328IR 3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp NIA Authorization No. NWA Expiration Date N/A Repair Organization Job #3b. NSM or MM # ON-23086 AM5 WP 23522A 4. Identification of System SG Secondarv DraIns clamq 2 ..5. (a) Applicable Construction Code ASME IIf NC 1989 Edition N/A Addenda, No Addenda /Code Cases N/A (b) Applicable Edition of Section XI Utilized tqr Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)
6. Identification of Components Rep ired or Replaced and Rep acement Components Column 1 Column 2 Column 3: Column 4 Column 5 Col. 6 Column 7 Column 8__ __ __ __ __ _ o ~ a uf otir rN ational Of e -e i c d~ A SM E C ode Manufacturer BoardOther Year Repaired, Replaced, Stamped Name of Component Name of. Manufachirpr Serial Numhpr Number dent~fl^at!on Bullt orReplacme.G,:t or now).Repaired Wo No r Replaced r yes A PIping Duke Power Company N/A N/A N/A 1974 r Replacement rRepalred r No I- Replaced F es c_ _ _ _ _r_ Replacement r RepaIred F No Dr Replaced r Yes C I- Replacement r Repaired r No I- ReplacedrYe D r Replacement Yes'F Repaired No rF Replaced Fe E rReplacement

/ Repaired F- No r- ReplacedFYe F ,- Replacement Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information in Items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Re-Install SG secondary drain pining for SG 2A.8. Test Conducted: F Hydrostatic r Pneumatic 17 Nominal Operating Pressure r Other r Exempt Page 2 of 2 Pressure _ _ psig Pressure psig Pressure _ _ _ psig Test Temp OF Test Temp _ _ OF Test Temp OF 9. Remark: ExIsting SG secondary drain plying had to be removed to allow removal of old SG and Installation of the new 2A steam generator. ThIs NIS-2 covers the welding for re-Installing this piping. Applled Code Case N-416-1.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A a toq >Expiration Date NIA vSigned E G L(3 On Date a9/zIC) f CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commision Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of CA _ and employed by 3- Ct have Inspected the components described in this Owner's Report during the period to ..3fr.4*: and state that to the best of my knowledge and bolief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or onnected with this inspection.

  • .O. Commissions

, Inspector's

  • n 1 ature Date _ 3 O9 National Board, State, Providence and Endorsement:;

Page 2 of 2 r r FORM NIS-2 OWNER'S REPr z JR REPAIRS OR REPLACEMENTS As Required By The Prow. as Of The ASME Code Section Xl C 1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 l.a Date 09/22104 Sheet 1 of 2 2a. Unit r I Pr 2 r3 r'Shared (specify Units)3a. Work Order # 98532818 Repair Organization Job #3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A 3b. NSM or MM # ON-23086 AM5 WP23522A 4. Identification of System SG Secondary Drain Lines Class 2 5. (a) Applicable Construction Code ASME IlIl NC 1989 Edition NWA -Addenda, No Addenda /Code Cases NA (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)
6. Identification of Components Repaired or Replaced and Replceent Cornponents

______________ -~ Column 1 Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 ]Column 8 iASME Code C Manufacturer Board Other Year Repaired, Replaced, Stamped (yesl Name of C Name of Manifacturer Serial Num ber Ideifliicaiion Buiut or Replacement or no).. Repaired i 7 No Hanger/Support .r Replaced r Yes A 2-04-0-1478A-H14A Duke Power Company N/A N/A WA 1974 F Replacement -Repaired P No Hanger/Support r Replaced FYes B 2-04-0-1478A-HlIA Duke Power Company W/A N/A N/A 1974 r Replacement _F Repaired Fo No Hanger/Support r Replaced r Yes C 2-04-0-1478A-H5A Duke Power Company NA N/A N/A 1974 r Replacement F Repaired 1 No Hanger/Support F Replaced F Yes D 204-0-1478A-H3A Duke-Power Company N/A N/A N/A 1974 r Replacement.F Repaired F7 No Hanger/Support rReplaced F Yes E 2-04-0-1478A-H2A Duke Power Company N _'WN/A NIA 1974 F Replacement ...17 Repaired F No Hanger/Support rReplaced rYes F 2-04A-0-1478A-H21A Duke Power Company NA N/A N/A 1974 r Replacement Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Remove and replace SG 2A secondary drain lines In support of SG RePiacement.

8. Test Conducted:

r Hydrostatic r Pneumatic r Nominal Operating Pressure r Other iv Exempt Sheet 2 of 2 Pressure _ _ psig Pressure _ _ psig Pressure _ _ psig Test Temp .F Test Temp __ OF Test Temp OF 9. Remark. LIsted hangers were removed for the removal of the 2A SG and replaced after Installation of the new replacement steam generator.(Applicable Manufacturer's Dala Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.Type Code-Symbol Stamp N/A Certificate of Authorization 1 o. N/A S Expiration Date N/A Signed __________________ Date J O +CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commision issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of CK and employed by UGS -Ct have inspected the components described in this Owner's Report during the period .z-i2'`4 to r and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. _ L .C). Commissions N .A.Inspector's SII)narre w w Bw w ax a a W _ _ z ffi National Board, State, Proviaerice and Endorsements Date 99- a 4 Page 2 of 2 r FORM NIS-2 OWNER'S REPO C As Required By The ProviA)R REPAIRS OR REPLACEMENTS is Of The ASME Code Section Xl C 0 1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 1.a Date 09/22/04 Sheet 1 of 2 2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 2a. Unit r I is 2'-3 r Shared (specify Units)3a. Work Order # 98532820 Repair Organization Job #3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A 3b. NSM or MM # ON-23086 AM5 WP 23522B 4. Identification of System SG Secondary Drains, Class 2 5. (a) Applicable Construction Code ASME ill NC > 1989 Edition N/A Addenda, No Addenda /Code Cases N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)

6. Identification of Components Repared or Replaced and Re ment Components

_ _j[ Column 1 Column.2 T Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8-_ ar __ _ E e National f r R ASME Code Manuacturer Board Other Year Repalred, Replaced, oStamped)(yes Name of Component Name of Mnd___rr Serfe! N *m$_r N-mbe I er Bun;ti:eatfoiiiot r Repiacement or no), Repaired rv No r Replaced A Piping Duke Power Company NWA N/A N/A 1974 rReplacement r Repaired r No r ReplacedF C r Replacement _____I Repaired F No rReplaced l Yes C _ _ _r__ _ _ _ _ _ _ _ Replacement__ F Repaired FrNo FrReplaced Ye D FReplacement FRepaired FN-F R p a i r d r -N o F Replaced Fe F F- Replacement P a e 1oE Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information in items 1 through 13 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Re-Install SO secondary drain pipina tor SO 2B.8. Test Conducted: r Hydrostatic F Pneumatic W Nominal Operating Pressure r Other r Exempt Page 2 of 2 (Pressure _ _ psig Pressure rI _psig Pressure -_ psig Test Temp___ 0 F Test Temp .OF Test Temp .OF 9. Remark Existing SG secondary drain Piminm had to be removed to allow removal of old SG and Installation of the new 2B steam generator. This NIS-2 covers the welding for re-installing this pyplng. Applied Case Code N-41641.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the ru es of the ASME Code, Section Xl.Type Code Symbol Stamp NWA Certificate of Authorization N91N/A Expiration Date NWA Signed / ViEebf_ Date 9Zf, CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commision Issued by the Neitional Board of Boiler and Pressure Vessel Inspectors and the State or Providence of CA_ and employed by vlee -CT_ have Inspected the components described In this Owner's Report during the period ; fLI3j to l-O and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in aomrdance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. A .0. t A a L Cnmmissions innt UA.k Inspectors SiknAure Date 9- 2s-o4 National Board, State, Providence and Endorsements Page 2 of 2 (FORM NIS-2 OWNER'S REPCt OR REPAIRS OR REPLACEMENTS As Required By The Provis...ns Of The ASME Code Section Xi I'.1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 1.a Date 09/22/04 Sheet I of 2 2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 2a. Unit 1 I W 2 r3 r Shared (specify Units _3a. Work Order # 98532820 3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A Repair Organization Job #3b. NSM or MM # ON-23086 AM5 WP23522B 4. Identification of System SG Secondary Drain Lines Class 2 5. (a) Applicable Construction Code ASME IlIl NC 1989 Edition N/A Addenda, No Addenda ICode Cases N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)

6. Identification of Components Repaired or Replaced and Replace t Components j Column 1 Column 2 Column 3 C m 4 Column 5 Col. 6 Column 7 j Column 8 National F ASME Code Manufacturer Board Other Year Repanred, Replaced, Stamped (yes Name of Component Name of Manufaturer Serial Number m.r Idenrsca;tion our o r Repiacement or no)FF Repaired ip- No Hanger/Support 17 Replaced rYes A 2-04A-0-1478A-H5B Duke Power Company N/A NA N/A 1974 r Replacement 17 Repaired rv No Hanger/Support Replaced Yes S 2-04A01478A-H3B Duke Power Company N/AA 974 rReplacement rvRepalred rv No Hanger/Support r Replaced r Yes C 204A-01478A-H2B Duke Power Company N/A N/A N/A 1974 r Replacement 17 RepaIred r1 No Hanger/Support r Replaced FYes D 2-04A-0-1478A-H14B Duke Power Company N/A NA N/A 1974 r Replacement iv Repaired 7 No Hanger/Support

.Replaced r Yes E 2-04A-0-1478A-H11B DukePower Company N/A A N/A 1974 r Replacement X 17 ~Repaired N Hanger/Support 2-04A-0-1478A-NPS. I- Replaced r Yes F H51 Duke Power Company NA NA N/A 1974 r Replacement Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form." 7. Description of Work Remove and replace SG 2B secondary drain lines In support of SG RePlacement.

8. Test Conducted:

r Hydrostatic r Pneumatic r Nominal Operating Pressure r Other Pr Exempt Sheet 2 of 2 I'Pressure _ _ psig Pressure _ _ psig Pressure _ __psig Test Temp *F Test Temp _ _ 'F Test Temp °F 9. Remarku Listed hangers were removed for the removal of the 2B SG and rePlaced after Installation of the new replacement steam generator.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the ru:'es of the ASME Code, Section Xi.Type Code Symbol Stamp NIA Certificate of Authorization No. A 6&P t SF-DL\op;L Expiration Date N/A Signed ____ ____ __ __ Date Zz.CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commision issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of CA _ and employed by t -CT_ have Inspected the components described in this Owner's Report during the period 2-1 to t-6 tr and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.By signing this certificate, neither the Inspector nor his employir makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. CnmMqiqinC-, 4k A &I ( o Inspector's SInOiure Date 9-2913-4 National Board, State, Providence and Endorsements Page 2 of 2 r FORM NIS-2 OWNER'S REPC' R )R REPAIRS OR REPLACEMENTS As Required By The Prov. t 1.,s Of The ASME Code Section XI (----- -1. Owner Duke Power Company Address 525 S. Church Street, Charlotte, NC 28201-1006 1.a Date 05/10104 Sheet 1 of 2 2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 2a. Unit r 1 r-3 r Shared (specify Units 3a. Work Order# 98537912 Repair Organization Job #3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp NWA Authorization No. N/A Expiration Date N/A 3b. NSM or MM # ON-23086 AM6 WP 23524A 4. Identification of System SG Vent System Class 2 5.(a)ApplicableConstructionCode ASME ilNC 1989 Edition N/A Addenda, No Addenda ICode Cases N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)

6. Identification of Components Repared or Replaced -and Re _entCopnents Column 1 Column 2 I Column 3 Column 4 -Column 5 Col. 6 Column 7 Column 8 National SECd Manufacturer Board Other Year Repalred, Replaced, Stamped (yes Name of Component Name of Manufacturer Serial Number Numtieronl tf!onti on tRiun!t or r In or no F Repaired F No r Replaced r Yes A Piping Duke Power Company N/A N/A N/A 1974 r Replacement r Repaired r No F ReplacedFYe B _r Replacement r Repalred r No r Replaced F Yes C FrReplacement r Repalred r No FrReplaced FrYes D r Replacernent rRepalred r No r ReplacedFYe E r Replacement FrRepaired FrNo, F rReplac r Ye s FPF Replacement Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x II in. (2) Information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Re-Install SG vent pDiing for SG 2A.8. Test Conducted:

r Hydrostatic r Pneumatic P Nominal Operating Pressure r Other r Exempt Page 2 of 2 (Pressure psig Pressure _ _ psig Pressure: psig Test Temp I OF Test Temp _ _ OF Test Temp OF 9.- Remarkt Existing SG-vent olilna had to be removed to allow removal of old SG and Installation of the new 2A steam generator. This NIS-2 covers the welding for re-installing Ithis pipina. Applled Code Casei'N-416-1.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the niles of the ASME Code, Section Xi.Type Code Symbol Stamp W/A Certificate of Authorization No N/A 5 Expiration Date N/A Signed f Date cTZZ/04 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commision issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of M C0 -__ and employed by RS 13 CT have inspected the components described in this Owner's Report during the period .Z:!.-7 to and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of anr kind arising from or connected with this inspection. DOLj,4 Commissions NMC M l A) T Date fnspei¶7c ature Date 9 0°V Nalional Board, State, Providence and Endorsements Page 2 of 2 C FORM NIS-2 OWNER'S REPC )R REPAIRS OR REPLACEMENTS As Required By The Provl%.. -as Of The ASME Code Section Xl--C 1. Owner Duke Power ComPay-Address 526 S. Church Street, Charlotte, NC 28201-1006 1.a Date 09/22104 Sheet 1 of 2 2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 2a. Unit F 1 i 2 r3 r Shared (specify Units 3 3a. Work Order # 98537912-3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A Repair Organization Job #3b. NSM or MM # ON-23086 AM6 WP23524A 4. Identification of System SG Vent Pipina Installation Class 2 5. (a) Applicable Construction Code ASME III NC 1989 Edition N/A Addenda, No Addenda /Code Cases N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)

6. Identification of Components Repaired or Replaced and Rep acement Component

_Column Column 2 Column 3 Column4 Column 5 Col. 6 Column 7 Column 8 NationalTS-ME Code N Manufacturer Board Other Year Repalred, Replaced, Stamped (yes Name of Component Name nof anf^-ur Serial Number Number -IdeInVL:o Bu;* or Replacemeni or no 1 Repaired PNo Hanger/Support r Replaced r Yes A 2-57-1481C-H6631 Duke Power Company N/A N/A N/A 1974 r Replacement 1W RepaIred 17 No HangerJSupport rReplaced r Yes B 2-57-1481C-H6632 Duke Power Company N/A N/A N/A 1974 r Replacement rRepalred rv No Hanger/Support F Replaced rYes C 2-50-1481C-H6642 Duke Power Company NWA N/A N/A 2004 17 Replacement r Repalred r7 No Hanger/Support r Replaced r Yes D 2-50-1481C-H6646 Duke Power Company N/A N/A N/A 2004 r7 Replacement rRepalred 1r No Hanger/Support r Replaced r Y E 2-50-1481C-H6640 Duke Power Company N/A N/A N/A 2004 17 Replacement r Repalred 17 No Hanger/Support r Replaced r Yes F 2-50-1481C-H6641 Duke Power Company N/A N/A N/A 2004 1 Replacement Page 1 of 2 Form NIS-2 (Back) Sheet 2 Of 2 NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 In. (2) Information in items 1 through E! on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Remove and replace SG 2A vent lines In support of SO Replacement.

8. Test Conducted:

r Hydrostatic r Pneumatic r Nominal Operating Pressure r Other P Exempt Pressure psig Test Temp .._F Pressure psig Test Temp OF Pressure psig Test Temp OF 9. Remark: Hangers were removed for the removal of the 2A SG and replaced after Installation of the new replacement steam generator. Several hangers are new.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xi.Type Code Symbol Stamp NWA Certificate of A orization No. N/A' $5 A sr-LtCb Expiration Date N/A Signed .) / Date O /7 a'/0 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commisioq issued bythe National Board of Boiler and P essure Vessel Inspectors and the State or Providence of YJI.z__ --_ and employed by 9 S C: have inspected the components described in this Owner's Report during the period .2IE:9 togII I;and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. __ _ ___ ~Commissions _ __tor's Signature National Board,6t ,'Providence and Endorsements V Date 9__3______ Page 2 of 2 r FORM NIS-2 OWNER'S REP' l OR REPAIRS OR REPLACEMENTS As Required By The Prov- .,ns Of The ASME Code Section Xi 1O-=wner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 1.a Date 09/22/04 Sheet 1 of 2 2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 2a. Unit F 1 F 2 r3 r Shared (specify Units 3a. Work Order# 98537912 Repair Organization Job #3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date NIA 3b. NSM or MM # ON-23086 AM6 WP23524A 4. Identification of System SG Vent Plolna Installation Class 2 5. (a) Applicable Construction Code ASME IlIl NC 1989 Edition N/A Addenda, No Addenda /Code Cases-N/A (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)

6. Identification of Components Rep ired or Replaced and Replacement Components Column 1 Column 2 Column 3 Column 4 Column 7 Col. 6 Column 7 I Column 8_ 7 a~onl rAISME Code.Manufacturer Board Other Year Repaired, Replaced, Stamped (yes Name of Comnonent Name of Manufacturer -Serial Number Number 1dantIcaon Bu:.:or Replacement or *MU 17 Repaired W No Hanger/Support r Replaced r Yes A 2-57-1481C-H6630 Duke Power Company N/A NIA N/A 1974 r Replacement rv Repaired rv No Hanger/Support

.Replaced r Yes B 2-50-1481C-H6643 Duke Power Company N/A N/A N/A 1974 r Replacement F Repaired PF No Hanger/Support r Replaced r Yes C 2-50-1481C-H6644 Duke Power Company N/A N/A N/A 2004 1o Replacement r Repaired 17 No Hanger/Support r Replaced -f Yes D 2-50-1481C-H6645 Duke Power Company N/A N/A N/A 2004 I Replacement F Repaired Pv No Hanger/Support r Replaced r Yes E 2-50-1481C-H6639 Duke Power Company N/A N/A N/A 2004 P Replacement r Repaired Pv No Hanger/Support r Replaced r Yes F 2-57-1481A-H6635 Duke Power Company N/A N/A N/A 2004 1v Replacement Page 1 of 2 Form NIS-2 (Back) Sheet 2 of 2 NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 1I in. (2) Information in items 1 through 6 on this report Is included on each sheet, and (3) each sheet is numbered and the numter of sheets is recorded at the top of this form.; -7. Description of Work Remove and replace SG 2A vent lines In support of SG Replacement.

8. Test Conducted:

r Hydrostatic r Pneumatic r Nominal Operating Pressure r Other F Exempt Pressure _ psig Test Temp OF Pressure psig Test Temp _F Pressure psig Test Temp _F 9. Remark: Hangers were removed for the removal of the 2A SG and replaced after Installation of the new replacement steam generator. Several hangers are new.(Applicable Manufacturers Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization No.14 2 i S ° Expiration Date WA Signed- ,/v-A Date CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commision issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of b and employed by N4 c;have inspected the components described In this Owner's Report during the period : to i- OLI ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection. P ^ g 9_ Commissions h--4 2 CIT lnspecka Signature National Board, State, Providence and Endorsements Date qg ,30'Page 2 of 2 f FORM NIS-2 OWNER'S REPOT OR REPAIRS OR REPLACEMENTS As Required By The Provi. -s O The ASME Code Section Xl 1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 l.a Date 09I22JO4 Sheet 1 of 2 2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 2a. Unit r I iv 2 r3 F Shared (specify Units 3a. Work Order# 98537912 Repair Organization Job #3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp W/A Authorization No. WA Expiration Date N/A 3b. NSM or MM # ON-23086 AM6 WP23524A 4. Identification of System SG Vent Plilna Installation Class 2 5. (a) Applicable Construction Code ASME IlIl NC 1989 Edition N/A Addenda, No Addenda /Code Cases N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.) IdAntification of Componontq Rensirnd or Rpnlarkd and RanIar-Lqmant OnmnnnAntS 6.vColumn 1 Column 2 1 Column 3 Column4 Column 5 Col. 6 Column 7 Column 8 National AM oi Manufacturer Board Other Year Repaired, Replaced, Stamped (yes Name of Component Name of Manufacturer Serial Number Number Identification Bult or Ren.oame nt or no1 r Repaired r No Hanger/Support F Replaced r Yes A 2-57-1481A-H6636 Duke Power Company N/A N/A N/A 1974 r Replacement P Repaired p No Hanger/Support F Replaced r Yes B 2-57-1481C-H6634 Duke Power Company NIA N/A N/A 1974 r Replacement .Repaired Pr No Hanger/Support r Replaced r Yes C 2-57-1481C-H6633 Duke Power Company NIA WA N/A 2004 1- Replacement rRepalred P No Hanger/Support r Replaced r Yes D 2-50-1481C-H6637 Duke Power Company WA NIA NIA 2004 17 Replacement r Repalred P. No Hanger/Support F Replaced r Yes E Sk-23086 AM6-035 Duke Power Company N/A NA N/A 2004 P Replacement r Repalred 17 No Hanger/Support r Replaced rYes F Sk-23086 AM6-057 Duke Power Company N/IA N/A A 2004 Replacement Page 1 of 2 Form NIIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information In items 1 through 13 on this report is included on each sheet, and (3) each sheet is numbered and the numbgr of sheets Is recorded at the top of this form.7. Description of Work Remove and replace SG 2A vent lines In support of SG Replacement.

8. Test Conducted:

Hydrostatic r- Pneumratic F Nominal Operating Pressure Other 1P Exempt Sheet 2 of 2 Pressure _ _ psig Pressure _ _ psig Pressure _ _ psig Test Temp _ _ OF Test Temp OF Test Temp ._ F 9. Remark. Hangers were removed for the removal of the 2A SQ and replaced after Installation of the new replacement steam generator. Severa I hangers are new.(Applicable Manufacturer's Dala Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization-N9IA N S Expiration Date N/A Signed , < , °Date qt i /o X I -- --.---. -.--- .- --- -. -__, CEH IFICATE OF INbERVICE; INSPECTION 1, the undersigned, holding a valid commision i'Su d by the National Board of Boiler and Pres§ure Vessel Inspectors and the State or Providence of .i ..__ and employed by I BC have inspected the components described in this Owners Report during the peiod to ff-IB s and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. jSO'_Q Commissions kJ S5 3 )Q T Inse~ Signature Date -q-3'0-0 National Board, State, Providence and Endorsements Page 2 of 2 C FORM NIS-2 OWNER'S REPf -nR REPAIRS OR REPLACENMENTS As Required By The Pro% is Of The ASME Code Section Xi il-1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 1.a Date 09/23/04 Sheet -of 2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 2a. Unit r1 r3 r Shared (specify Units I 3a. Work Order # 98537912 Repair Organization Job #3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A 3b. NSM or MM # ON-23086 AM6 WP 23524A 4. Identification of System SG Vent System Class 2 5. (a) Applicable Construction Code ASME III NC 1989 Edition N ,A Addenda, No Addenda /Code Cases N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)

6. Identification of Components Rep ired or Replaced and Replacement Components Column 1 Column 2 Column Column 4 Column 5 Cl. 6 Column 7 Column 8 Manufacturer Board Other Year Repaired, Replaced, Stamped (yes Name of Comoonent Name of Manuf__irer Seril Numbe Nu1mbrli rantorno r Repaired F No F Replaced rv Yes A Valve 2FDW-601 Flowserve 80AXS 1189 N/A 2003 rF Replacement r Repaired F No CF Replaced W Yes B Valve 2FDW-604 Flowserve 84AXS 1193 N/A 2003 F7 Replacement

_____r Repaired r No Fr Replaced Yes C _ _ _ _ _ _ _ _ Replacement _ _r Repaired r No r Replaced r Yes D _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _r R eplacem ent r Repalred F No FrReplaced r Ye F _Replacement FPRepaired FNo rReplaced Y-~es F _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _rR eplacem ent Page -_ atf Form NIIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 112 In. x 11 in. (2) Information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Re-Install SG vent piping for SG 2A.8. Test Conducted: r Hydrostatic r Pneumatic rv Nominal Operating Pressure r Other r Exempt Pressure psig Test Temp.Pressure _ _ psig Pressure _ _ psig Test Temp OF Test Temp _ OF 9. Remarks Existing SG vent DlolnLa had to be removed to allow removal of old SG and Installation of the new 2A steam generator. Modiflicatlon Involved Installlna new valves.Applied Code Case N-416-1.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the files of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A S Expiration Date N/A Signed ' Date_________ CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commision issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of -NCm _ and employed by MSBCx have inspected the components described in this Owner's Report during the period 1;to Y a ; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concemning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions Wt S 3, S fninspto? Signature National Board, State, Providence and Endorsements Date !303 9'%Page _ of _ Page 3 of S WP 23524A Valve Traceability Table DPC Stock Code UTC MCN Valve Number Serial No.538523 1064621 P078-0901 2FDW-601 80AXS 538523 1065255 P078-0904 2FDW-604 84AXS Aug 31 04 1 1:17a Oconee QPA 864- 885 -400 1 p. 6 FORM NPV-1 N CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVEs'.As Required by the Provisions of the ASME Codeo Section III, Dlv. I h _9_ I Of 1. Manufactured by TMr fIU7CVrW I'mbADATnf.- l6firl C .A..-A C&l0-1-t-h %Tr tkn A La .Lfl A A-A v A_ .-- -.--A v- -a o , am. fla t 8M5 zl .u (Mann asn Mtss of N Cr~iaicokHe.

2. Manufactured for DUKE ENERGY CORP CH{ARLO1TE NC 28201_ ., .(Nane SAM.s of Pewchas o ownw D)UKE ENERGY CORP. OCQtE SENECA SC 29672 3. Location of Installation,.
4. Pump or Valve ,_-{~(Iam ana AM sls Nominal Inlet Size Valve 1 m1/2 Outlet Size I1 " XW (a) Model No.Series No.or Type (b) N Certificate (c) Canadian Hocders Regisragion Serial No. No.(d) Drawing No.(0 Nat'L Bd. No.(g) Year Built (e) Class-(1) 800 GB 80AXSt/ N/A 03-25070-01/0 1 1189 V 2003 (2) 81AXS V/ 1190 V (3) .82AXSJ>1-9 (4) AXS L-2 (5) 84AXS 1193 (6) 85AXS- 1194 (7) 86AXS 11 9 5t 7 (8) 800 GB 87AXS ' NWA 03-25070-01

/0 1 1196 2003 (9)(10)2.1I/2" GLOBE VALVE (SM1 desaiptond seri kr which aquipmrm was desdgnod)§.25070 6.7._t Design Conditions 1425 \ /(P-)Cold Working Pressure 1973 Presstrn Retalninn Pbcer psi 680 .A' or Valve Pressure Class psi at 100 'F.800 ./(1)Mark No. Material Spec. No. Manufacturer Remarks (a) Cas.t s _.. _ _._M7908V SA216 GRLWCII FLOWSERVE BODY -_ _ _ _ ._ _ _H SA479 T316 NOVA L)X1kNET --H590 .A56 T630 1075 _ NOVA _,______Q 754-G3oX, SA564 T630 1075 ASKEW U;A!;KET RETAINER (1) For manually operated valves only i 'w Supplementat sheets in form oliUsts, sketches or drawings may be used provided (1) size is s-1r x iV. (2) Informarion I itens 1.2 and 5 o Data Report Is Included on each sheet. and (3) each sheet Is numbered and number of sheets Is recorded at top of this form.FP ;A. 4A CFS S V (\fj f Z,3 S2.rA0 VALVES 'ZF~hw (P& -& Q _) Rug 31 04 11:17a Oconee 4R 864-805-4001 p .7 FORM NPV-1 (Back)Pg.2of 2 Valve S/N JX.SOXS_ through _87AXS_Mark No. Material Spec. No. Manufacturer Remarks (c) Bolting _-(d- O -ther Paris _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _S. Hydrostatic test 2975 psi. Disk Dif'ferentil1 test pressure 2171 Ps.CERTIFICATE OF COMPLIANCE We certify that the statements made In this report are correct and that this pump, or valve. to the a o trction conforms I98 of the ASME Code for Nuclear Power Plant Components. Section III, Div. I.. Edition Addenda NO ,Code Case No. Date Signe d Fowserve Corporation, by I ( offcae m_ .I Our ASME Certificate of Authorization No. N-1562 to use the N symbol expires 11-26-06 IN) Coate)CERTIFICATION OF DESIGN Design Ifraino leatFO SRECORP Stress analysis report (Class I only) on file at FLOWSERVE CORP Design spec~ficatlons certified by (1) FA B3ENSINGER PE State PA Reg. No. PE-31002-E Stress analysIs certified by IF) RONALD S FARRELL PE State NC Reg. No. 028656 (1) Signature not required. List name only.CERTIFICATE OF SHOP INSPECTION

1. the undersigned.

holding a valid commission Issued by the National Board of Bofler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT .of Hartford Connecticut have Inspected the pump, or valve, described In this Data Report on JJ.JZ t lo l..Z ..3 andstate that tothebestof myknowledgeand belief the N Certificate Holder has constructed this pump. or valve, In aicrdance with ASME Code, Section Ill.By signing (his certificate neither the Inspector nor his employer makes any warranty, expressed or Implied. concerning the equipment described in this s Data Report. Furthermore, neither the Inspector nor his employer shall be lable In any manner for any personal Injury er property damage or a loss of any kind arising from or connected with this Inspection. Commkslons A66 V41/A 4) (A Al.-I F (oftliCo (I (Mn fdt.S e, PrMY. WNq)PjS oF S FORM NIS-2 OWNER'S REPr v OR REPAIRS OR REPLACEMENTS As Required By The Proaw is Of The ASME Code Section Xl c 1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 l.a Date 09123/04 Sheet 1 of 2 2a. Unit r 1 P12 r3 r, Shared (specify Units 3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A 3a. Work Order# 98537914 Repair Organization Job #3b. NSM or MM # ON.23086 AM6 WP 23524B1 4. Identification of System SG Vent System Class 2 5. (a) Applicable Construction Code ASME III NC 1989 Edition -/A& Addenda, No Addenda /Igde Cases NA (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)
6. Identification of Components Rep ired or Replaced and Replacement Components Column 1 Column 2 Column 3 Column 4 Column 5 Col.6 Column 7 Column 8_ME Code Manufacturer Board Other Year Repaired, Replaced, Stamped (yes Name of Comnonent Name el I.aun,.u9'Ja.

I -NiUmhvt Nuation .. or ASmE Cor dI 1 Repaired P No r Replaced r Yes A Piping Duke Power Company N/A N/A N/A 1974 F Replacement r Repaired r No r Replaced rYes B r Replacement r Repaired I No r Replaced F Yes C r Replacement F Repalred r No r Replaced D r Replacement r Repalred F No r Replaced r Yes.r Repaired f- No r Replaced Ye F .F Replacement Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Re-install SG vent line DiPing for SG 2B.8. Test Conducted: r Hydrostatic r Pneumatic P Nominal Operating Pressure r Other r Exempt Page 2 of 2 Pressure _ _ psig Pressure _ _ psig Pressure _ _ _psig Test Temp OF Test Temp _ OF Test Temp _ _ 'F 9. Remark! Existing SG vent line pnllna had to be removed to allow removal of old SG and Installation of the new 2B steam generator. This NIS-2 covers the welding for re-Installing this plPlng. Appiled Code Cse N-416-1.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPIUANCE We certify that the statements made In the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.Type Code Symbol Stamp WA Certificate of Authorization No. OA -5;t6-f? \ Expiration Date N/A Signed __________________ Date 07/Z3 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commislon islued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of __t and employed by .S { 7 have inspected the components described In this Owner's Report during the period 2-7°'t to .J- PyL; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions_ A-), Inspectors Signature National Board, State, Providence and Endorsements D ate _ _ _ _ _ _ _ _Page 2 of 2 C.r FORM NIS-2 OWNER'S REP( _ OR REPAIRS OR REPLACEMENTS As Required By The Prov.. ,ns Of The ASME Code Section Xl I 1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 1.a Date _09/23/04 Sheet 1 of 2 2a. Unit ri W 2 F3 r Shared (specify Units 3a. Work Order # 98537914 3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A Repair Organization Job #3b. NSM or MM # ON-23086 AM6 WP23524B 4. Identification of System SG Vent Pioing Installation Class 2 5. (a) Applicable Construction Code ASME III NC 1989 Edition N/A Addenda, No Addenda /Code Cases N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)
6. Identification of Components Repaired or Replaced and Replacement Components Column 1 Column 2 Column 3 Column4 Column 5 Col. 6 Column 7 Column 8 Manufacturer Board Other Year Repaired, Replaced, Stamped (yes Name of Component Name of Manufacturer Se-ria! Number NumwrF identification Bullt or Replacement or no)de r Repalred rv No Hanger/Support r Replaced r Yes A 2-50-1480A-H6647 Duke Power Company NIA NWA NWA 2004 ro Replacement Fr Repaired R No Hanger/Support Fr Replaced r Yes B 2-50-1480A-H6648 Duke Power Comp any N/A N/A WNA 2004 r Replacement r Repalred PF No Hanger/Support r Replaced F Y C 2-50-1480A-H6649 Duke Power Company N/A N/A N/A 2004 rv Replacement r Repaired 17 No Hanger/Support r Replaced r Yes D 2-50-1480A-H6650 Duke Power Company N/A N/A N/A _ 2004 r Replacement I Repalred R No Hanger/Support r Replaced r Yes E 2-57-14808-H6619 Duke Power Company N/A N/A N/A 2004 F Replacement r Repalred F No Hanger/Support rReplaced r Yes F 2-57-14808-H6620 Duke Power Company N/A N/A N/A 2004 rv Replacement Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Remove and replace SG 2B vent lines In support of SG Replacement.
8. Test Conducted:

F Hydrostatic r Pneumatic r Nominal Operating Pressure r Other P Exempt Sheet 2 of 2 Pressure _ _ psig Pressure _ _ psig Pressure _ _ psig Test Temp _ _ OF Test Temp _ _ 'F Test Temp OF 9. Remark. Hanaers were removed for the removal of the 2B SG and replaced after Installation of the new replacement steam generator. Note: Several of these hangers are new.(Applicable Manufacturers Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xi.Type Code Symbol Stamp N/A Certificate of Authorization No. NlA 5 E Expiration Date N/A Signed_ Date __3__ __ D CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commisionjsued by the National Board of Boiler and PV ssuE Vessel Inspectors and the State or Providence of AJ( _ and employed by 4 Sf l(IC7_ have inspected the components described in this Owner's Report during the period A-7ay to g and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss ef any kind aris m or connected with this inspection. zv)~ Co mmissqions-mc s....... ... _ _ _, ., lislpecto Signature Date 9 -- )National Board, State, Providence and Endorsements Page 2 of 2 (r FORM NIS-2 OWNER'S REP( ~- 'OR REPAIRS OR REPLACEMENTS As Required By The Provtb..ns Of The ASME Code Section Xl 1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 1.a Date -09/23/04 Sheet 1 of 2 2a. Unit r I 172 r3 r Shared (specify Units)3a. Work Order# 98537914 Repair Organization Job #3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A 3b. NSM or MM # ON-23086 AM6 WP23524B 4. Identification of System SG Vent Ploina Installatlon Class 2 5. (a) Applicable Construction Code ASME IlIl NC 1989 Edition N/A Addenda, No Addenda -/Code Cases NA (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)
6. Identification of Components Repared or Replaced and ensCo onent I Colum n1] Colum n 2 Column 3 lColumn 4 Column 5 Col. 6 IColumn 7 Column 8 I I National F ASAME Code I l Manufacturer Board Other Year Repaired, Replaced, Stamped (yesl Name of Component Name_ __ Mn__a___._____

S a NumbAear Number ident cation Built or Replacement or no)r Repalred r7 No Hanger/Support F Replaced r Yes A SK-23086 AM6-036 Duke Power Company N/A N/A N/A 2004 1R Replacement r Repaired W No Hanger/Support r Replaced r Yes B 2-57.1481A-H6614 Duke Power Company N/A N/A N.A 2004 P Replacement F Repaired 17 No Hanger/Support r Replaced r Yes C 2-57-1481A-H6611 Duke Power Company NA N/A N/A 2004 17 Replacement r Repaired WI N o Hanger/Support r Replaced r Yes D 2-57-1481A-H6624 Duke Power Company N/A N/A N/A 2004 P Replacement F Repaired P"No Hanger/Support r Replaced F Yes E 2-57.1481A-H6651 Duke Power Company N/A N/A N/A 2004 17 Replacement r Repaired PNo Hanger/Support r Replaced r Yes F 2-57-1479A-H6612 Duke Power Company N/A N/A NA 2004 7 Replacement Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Remove and replace SG 2B vent lines In support of SG Replacement.

8. Test Conducted:.

r Hydrostatic r Pneumatic r Nominal Operating Pressure r Other P Exempt Sheet 2 of 2 Pressure _ psig Pressure _ _ psig Pressure _ psig Test Temp _ OF Test Temp OF Test Temp OF 9. Remark. Hangers were removed for the removal of the 2B SG and replaced after Installation of the new replacement steam generator. Not>: Several of these hangers are new.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to thi rules of the ASME Code, Section Xi.Type Code Symbol Stamp N/A Certificate of Authorization No. NI S & 51V' Expiration Date N/A Signed Hi Date 'Y CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commisioq issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of NC and employed by have inspected the components described In this Owner's Report during the periocd 25 tol uko -t andstatethatto the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures descrited in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss ol any kind arising from or connected with this inspection. _ Crnmmiainsn' At )(f, &S3,1ALT Inspe or's Signature Date -3 /Ad ... v ....., --_, , -I_National Board, State, Providence and Endorsements Page 2 of 2 (k FORM NIS-2 OWNER'S REPENT FOR REPAIRS OR REPLACEMENTS As Required By The Prt ' -as Of The ASME Code Section XI 1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 1.a Date 08/31/04 Sheet -of 5 2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 2a. Unit r 1 Pr2 rs r Shared (specify Units)3a. Work Order # 98537914 Repair Organization Job #3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A 3b. NSM or MM # ON-23086 AM6 WP 23524B 4. Identification of System SG Vent System Class 2 5. (a) Applicable Construction Code ASME ill NC 1989 Edition N/A Addenda, No Addenda jgode Cases N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)

6. Identification of Components Repaired or Replaced and Replacement Components

___-Column 1 Column 2 l Column3 Column4 Column5 Col6IColumn7 Column8l N-O ASME Code Manufacturer Board Other Year Repaired, Replaced, Stamped (yes Name of ComponentName of Manufacturer Serial Number Number Identlflcation Built 'or Replacement or no)r Repaired r No r Replaced r Y., A Valve 2FDW-606 Flowserve 81AXS 1190 N/A 2003 1;7 Replacement F Repaired F No r Replaced Wo Yes B Valve 2FDW-609 Flowserve 83AXS 1192- N/A 2003 fr Replacements r Repaired r No r Replaced r Yes C r Replacement _r Repaired r No r Replaced r Yes D r- Replacement F Rtepaired r No r Replaced Ye E r__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ R eplacem ent FrRepaired FrNo FrReplaced r Yes IF -F Replacement Page .jo ---I Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size Is 8 1/2 in. x 11 in. (2) Information In items 1 through 6 on this report is included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.7. Description of Work Re-install SG vent piping for SGi 26.8. Test Conducted: r Hydrostatic r Pneumatic P1 Nominal Operating Pressure r Other r Exempt Pressure _ _ psig Pressure _ _ psig Pressure _ psig Test Temp___ OF Test Temp OF Test Temp ..OF 9. Remarks Existing SG vent piping had to be removed to allow removal of old SG and Installation of the new 2B steam generator. Modification Involved Installing new valves.Aeflied Code Case N-416-1.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization No.,WA 5e f ft. Expiration Date NA Signed E &c Date 9 _Z3O'4 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commision issved by the National Board of Boiler and y Inspectors and the State or Providence of p and employed by -have Inspected the components described in this Owner's Report during the period F;-o to t*I8L: and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASIAE Code, Section Xi.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. JA Commissions is A), I lnsipe~o' Signature National Board, State, Prcfvidence and Endorsements Date Cl X I Page Z of ,: Page 3' of 5 WP 23524B Valve Traceability Table DPC Stock Code UTC M[CN Valve Number Serial No.538523 1065253 P078-0902 2FDW-606 81AXS 538523 1065254 P078-0903 2FDW-609 83AXS Rzug 31 04 1 1: 17a Oconee QR 864 -885 -400 1 P. 6* FORM NPV-1 N CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES-AsRequired by the Provistons of the ASME Code, Secion i11, Div. 1 L I-1O__1. Manufactured by WInWSERVE CORPORAiON. 1900 S.Saunders -t.U Refiuh NC! 276Q3 (- -mW Addms of N Cedi cat.Holde)

2. Manufacdured for DUKE ENERGY CORP CHARLOT NC 28201_NeO mnd)tsr a( Pgcftsa 4 0MWO WITZMF VPJVrGY CORP. OCrfNtE SEC~r-A SC 296QA72 3. Location bf Installatlion
4. Pwnp or Valve-wM arm AowuSmJ Nominal Inlet Size Valve I 1/2" Outlet Sizm I n (a) Model No.Series No.or Type (b) N Certificate Holdees Sedal No.(c) Canadian Registration No.(d) Drawing No.(M NatL Bd. No.(g) Year Built (e) Cass (1) 800 GB 80AXS./ NSA 03-25070-0110 1 1189 V 2003 (22 81AXS 9/ 0 V (3) 82A3*(4) '--t3A--S
  • -' -I T92I/t5) 84AXS v, 1193 (6) 85AXS-*'6 1194 (7) 86AXS v' 1195.$'(8) 800GB 87AXS MA N/A 03-25070-0110 1 1196t,," 2003 (9)(10)5. 11 2"LOBE VALVE WO~ei desaiporwi CI segvlce lor ut~kh eukaulpnwW was dagww4)25070 6. Design Condtitons 1425 psi 680 'o or Valve Pressure Class _ 800 _ 7 (1)(P- -sP) WA(Tepuah)
7. Cold Wodrlng Pressure 1973 psi at 100 F.8. Pressure Retaining Pieces __Mark No. Material Spec. No. Manufacturer Remarks (a) Castings __________

M790ff SA216 GR FAMOWSERVE = BODY -H5SA479 T316 L"0 NOVA LpergNET H590 ,A564 T630 1075 Z ~ NOVA ________Q17S4-GS6X SA564 T630 1075 ASKEW ASKf.W ET RETAINER-(1) For manually operated valves only-supptementat sheets in frmnof Usts, sketches ordrawings may be usedprovided(1) sze Isa5-l12xil" (2) lInformation in Wrins 1. 2 and 5 o~.I Data Repodt Is Included on each sheet. and (3) each sheet Is numt~ered and number of sheets Is recorded at top of thIs. form.,..0 _. S._-_w _ .4, ~ \ e ucoflee U,-, P.'"UG JL U-t 11:1fa uconee wln Iduat-a8 -400lu1 p .7 FORM NPV-1 (Back)Pg.2of 2 Valve SIN _OAXS throuch _87AXS Mark No. Material Spec. 14o. Manufacturer Remarks (c) Bothing (d) O ther Parts _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _9. Hydrostatic test 2975 psi. Disk Differential test pessure 2171 psi.CERTIFICATE OF COMPLIANCE We certify that the statements made In this report are correct and that this pump, or valve, to the mies of construction conforms 1986 of the ASME Code for Nuclear. Power Plant Components. Section III, Div. I., Edition Addenda N. Code Case No. NIA Date Signed Flowserve Corporation, by X.___ _ _ _ _ _ _ _ _ _ _ _ __ .OurASME Certificate of Authorization No. N-1562 to use the N symbol expires 11-26-06 IN) 11[we)CERTIFICATION OF DESIGN Design Information on filee at FLOWSERVE CORP Stress nayereo (lsIonyonfeatFLOWSERVE CORP Desin secitatint er~ed b (1 FABENSINGER PE State PA Reg. No. PE-31002-E Stress analysis certified by (1) RONALD S FARRELL PE State NC Reg. No. 028656 (1) Signature no required. List name only.CERTIFICATE OF SHOP INSPECTION I, the undersigned, hokding a valid commission Issued by the National Board of Boller and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HISB CT .of Hartford Connecticut haveinspectedthepumpp.orvalve. describedinthis DatalReportorn It I lJ JD3 .,andstalethattothebestof myknowedgeand bened, the N Cerficate Holder has constructed this pump, or valve, il accordance with ASME Code, Section fit.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or niplied, concerning the equipment described in this s Data Report. Furthermore, neither the Inspector nor his employer shalt be Eable In any manner for ary personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. Dated 7 '1- o in.j3.., A, rpi V A rnnn~m IA a ll: AN -T i- Al"'6 -Z---.- .-----...... -------7 9 -bdf I (Ran Sd.,S1W. Pt&. WgP (Wp 232IS V S eJ C-FORM NIS-2 OWNER'S REPr 1. OR REPAIRS OR REPLACEMENTS As Required By The Prov ns Of The ASME Code Section Xi 1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 1.a Date 09/23/04 Sheet 1 of 2 2a. Unit F 1 P72 r3 r Shared (specify Units 3a. Work Order # 98541036 3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp NWA Authorization No. N/A Expiration Date N/A Repair Organization Job #3b. NSM or MM # ON4-23086

= 0110d"'4. Identification of System Chemical Addition System Class 2 5. (a) Applicable Construction Code ASME II1 NC 1989 Edition N/A Addenda, No Addenda /Code Cases N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)

6. Identification of Components Repaired or Replaced and Replacement Components Column 1 Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8 I-National ASME Code Manufacturer Board Other Year Repaired, Replaced, Stamped (yes NmofCmoetName of Manufacturpr Srlal Number Number I'de...tifiatiu Buiit or Replacement or no)r Repaired 17 No-Replaced rr Yes A Piping Duke Power Company N/A N/A N/A 2004 1;7 Replacement r Repalred r No r Replaced r Yes S r Replacement r Repalred r No r Replaced r Yes C F- Replacement r Repalred r No r Replaced rYes D F Replacement rRepalred r-No I-Replaced r YeslE rReplacement rRepalred r No I Replaced r Yes F rReplacement Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size Is 8 1/2 in. x 11 in. (2) Information in items 1 through S on this report is Included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Install new Chemical Addition flow palh for both Unit 2 SGs..8. Test Conducted:

r Hydrostatic r Pneumatic F Nominal Operating Pressure r Other r Exempt Page 2 of 2 Pressure _ _ psig Pressure _ psig Pressure _ psig Test Temp OF Test Temp _ _ 0 F Test Temp 2 O F 9. Remark. SGRH Project added this mod per ONS request to add an addition method of adding chemicals to the Unit 2 SGs.. This NIS-2 covers the weldina for Installation of this pioing. Applied Code Case N-416-1.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A So2 Expiration Date N/A Signed ; Date CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commision issued by the National Board of Boiler and Pres Vessel Inspectors and the State or Providence of _ and employed by M S u50Tr have inspected the components described in this Owner's Report during the period ;to ; andstatethat to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Cocle, Section Xl..By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions t 1 YS3t A.Ins rector's Signature Date 0 M National Board, State, Providence and Endorsements I IPage 2 of 2 C(FORM NIS-2 OWNER'S REP r NOR REPAIRS OR REPLACEMENTS As Required By The Pros. .ens Of The ASME Code Section Xl 1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 1.a Date 09123/04 Sheet of 2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 2a. Unit r 1 17 2 r 3 r Shared (specify Units 3a. Work Order # 98541036 Repair Organization Job #3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp NIA Authorization No. N/A Expiration Date N/A 3b. NSM or MM # ON-23086 BM3 WP 23527 4. Identification of System Chemical Addition Svstem Class 2 I ---,_5. (a) Applicable Construction Code ASME ill NC 1989 Edition N/A Addenda, No Addenda iCode CasesIN/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)

6. Identification of Components Rep ired or Replaced and Rep acement Components Column 1 Column 2 Column 3 Column 4 Column 5 l Col. 6 {Column 7 Column 8 National I i Cd Manufacturer Board Other Year RepaIred, Replaced, Stamped.(es Name of compuwentc Ni.... ' oanu-aclurer Serial Number Identification Built or Replacement or no)rRepaired rNo r N rReplaced 117 Yes A Valve 2FDW-594 Flowserve 84AXJ 1149 N/A 2003 W Replacement

.Repaired r No r Replaced Po Yes B Valve 2FDW-595 BNL Industrial A981103-4-14 N/A N/A 2003 ro Replacement r Repalred r No r Replaced r Yes C r Replacement r Repalred r No r Replaced r Yes D r Replacement r Repalred r No r Replaced r Yes E rF Replacement r Repaired r No r Replaced r Yes F r Replacement Page__ of_ Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 In. (2) Information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Install new Chemical Addition flow lath for SGs 2A & 2B.8. Test Conducted: -r Hydrostatic r Pneumatic li Nominal Operating Pressure r Other r Exempt Pressure psig Test Temp.OF Pressure psig Pressure psig Test Temp __ OF Test Temp 'F 9. Remarka The BM3 mod Included adding a new alternate method to add chemicals to the steam generators. The modification Involved Installing new valves. Appled Code Case N-41 6-1.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A .5 R S tfb P Expiration Date N/A Signed Z J Date ../CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commision issued by the National Board of Boiler and Pree sel Inspectors and the State or Providence of JK el._ and employed by 4hea r have inspected the components described in this Owner's Report during the period ii to S AL; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal injury or property damage or a less of any kind arising from or connected with this Inspection. Commissions A)3 , A I--- -------Irnspr r's Signature Date 9-30 V National Board, State, Pro'vidence and Endorsements Page _ of _ Page.-3 of 7 WP 23527 Valve Traceability Table DPC Stock Code UTC M[CN Valve Number Serial No..I 461336 1061349 P098-0905 2FDW-594 84ALXJ 453842 1061603 P107-0894 2FDW-595 A981103-4-14 Aug 31 04 11:16a Oconee QA 664-865-4001 P.2 Rue 31 04 11: 16a Oconee QR 864-885-4001

p. 2 A ilJ.J30a3t.

r L1.W^Wr_ rI.AL Ob* CERTIFICATE HOLDERS' DATA REIPORT FOR NUCLEAR PUMPS OR VALVES' CORRECT0 COPY As Required by the Provisions oa the ASME Code. Section IUL Div. 1 Pg. I of. 2 VLOWSERVE CORPORA1TION. 1900 S. Ssunders St., Raleirh. NC 27603 i-Manufactured by-Nre andi Aidri at N cw@Octe NMiM)2. Manufactured tor DtUK ENERCGY CORP CHAILOTTE NC 28201 (maim LandMdi or PDu;Oafarcr o nSC2 3. Location of Installation DUKE ENERGY CORP. OCO NJ 1 SEnZCA SC 29672 L.-_ .4. Pump or ValW Valve (N-' WN AddC Nominal IlretSize I 1 2 -OutletSize (ca.)1 1/ -prC:t'(a) Model No.Series No.or Type (b) N Certificate Holder's Serial No.(c) Canadian Regestraion No.(d) Draw'ng No.(ft Narl.13d. No.(e) Class (g) Year Built (1) 1S78#SC 84AXJ ' NIA 03-25064-011 A 1 1149 = 003 (2)(3)(4)(7)(8)(9)(10).. _I 1 /2" SWING CHECK VALVE pdat dewpfianr ,serwice for Wih ,KuInbeftnh was des;gned)25064 6. Design CondItions 345 psi 680 L F or Valve Pressure Class 1878 (1)(Pc°5=C) eremperatuc)

7. Cold Wording Pressure 4637 ps 1 a t 100 OF.8. Pressure Retaining Pieces __*Mark No. Materlal Spec. No. Manufacturer Remarks (l Castings _M2777 SA216 GR WCB '- TECH CAST BODY 1G3875 SA.479 T 316 -- COLONIAL BONNET Y-F5D5 *7 SA564 T 630 1075 i,- NOVA DISC 72240 s- A479 T316 is.- DUB OSE BONNET RETAJNER.__ __(1) For manually opeaed valves only'SupplermentalsheetsIn frm of sts skcetches or drawrings triy be use4 provided (1)size is 8-li? ix I' (2) infotmatlon Is ke~ms 2 and Asthis Data Report is Included on each sheet, and (3) each sheet Is numbered arid nurnber of sheets Is recorded at top of hils fcerm.lG87 SA.7 T, 31 _ COt)IA 1r3)(-e 23SZ-7, V.tLvES -

Aug 31 04 11:16a Oconee QR 864-665-4001 p.3 PAGE 07/9198313376 , 1 dNPV-1 (Back)FLOWSERVE Pg.2of 2 Valve SIN 3413 tFhrough _I I _mark No.Material Spec. No.MAanufacbrer Remarks (c) Boating -_.___._(d) Other Parts _ _ _ _ _ _ _ _ _ _ _ _ _.t S.~~ _yrsalts 695., ihDffrnilts resr 11 P, CERTIFICATE. OF COMPLIANCE We ceslfy that the statements made In Ui5a report are correct and that this pump, or valve, confonns of the ASME Code for Nudear Power Plant Components. Section il. Dlv. t.. Edition 41 Addenda NO , Code Case No. N/A .D2to Signed Flowserve Corporation. by to the rulen of construction 1986 L (N CLr-mIle IUdeQ Our ASME Certiicate of Authoriaton No. N-1S62 to use the IN, symbol expires 11-26-03 ;1n~.I CERTIFICATION OF DESIGN Desin Informafn on fie at FLOWSERVE CORP eI5 analysis report (Cass 1 only) on fie at FLOWS1RVF CORP Oesign specitlcafons ffed by (1) F A D8ENSYNZ ER PE Stake PA Reg. No, fl-31002-E Stress analysIs certified by (1) RiONALD S FARRELL PE Slate NC Reg. NM 02S656 (1) Signakure not required. tst narne only.CERTIFICATE OF SHOP INSPECTION

1. the undersigned, hbldhig a valid commission Issued by the National Board of Boiler end Pressure Vessel inspectors and the Slate or Prtince of North Carolina and employed by _4. HSES CT -of Hartfcord Connecticut have Inspected the pump. or valve, described in this Data Report on _f tJ Z joy and state that, to The best of my knowledge snd belief, the N Cerfificzte Floder has constructed thk pump. orvlve, h accordance wathASltE Code. Secton Ill.By signing tIis cerlificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the equlipment described In this. Data ReporL Furthermore neiter thenspeclornorhis emplyershall belable Inanymanner frwypersonal iurnyor propeydamage ora lost of eny kind arising torn or connected with this Inspection.

Date I 1 A-, , "or &1 /co Signed WAnssln loSf/I, C -scm PW of. 5O:tPF-. sntNo.)Pp PJL 5 oF 7 (viP z35z?, Vqwlajr ZFIW-St- S'tS 84E 5 001 p. 4 Rue 31 04 11:16a Oconee QR 864-685-40 FORM NPv-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVI.^S As Requlned by the Provisions ol' the ASME Code, Section 111. Division I Pg. 11 of 2 1. Manuacbturdnd ldby BNL INDUSTRIE';, INC., 30 INDUSTRIAL PARX ROAD, VERm;ON, CT, 06066 nM end Vddra of N Certfit Helddd 2. MasnulscUredfor DURE POWER CO, PO BOX 1015, C-CARLOTTE, RC 28201-1015 lwna and ddreus of Pwihter)3. LocationointatiationV15C NUCLUR STATION, HIGHWAY 183, SENECA, SC 29678 (name and eddregal VALVE -HBV-A2-20-0036 0 4. Model No., Seres No., arType -Dr& Rev. ~ CR N-5. ASME Code. Secion Hlt, Dfivison 1: i989 2 Lt-ledtoni lddendeladl Ileel nICU Case r.1 6. PFmp or vlve- PLVE NorInal inlet sa. Z. 4 .1p_ Ouetb , 2;7_oy S0 _SA1OS SA 479 TY316 eo*tig SA193GrB7/SA194Gr2H (aI 1 I Cert. NMI Holder-s Board Seribl No. No.C-A981103-4-R Qga 281103-4 -(16) ;?Cr)id)Body Bonnet Serial Serial No. No._ _ _ _ N56_2 -' 5 (a)Dil.d Serici No.N3_._ ._I%*Spplramstel hIforatdon hI ferrtat gets. Akschden ar *Swlnge may be ued provided (1 sun is BY& x 11. 121 htformetlan hi Itna 1 duouqh4 on tl Data Report k kuded on each 1eee,31 each she Is numered end wdtha numatf shet*a recorded at rh top of ate form.(121881 TbI4 km CE00037 may ba ebtained from de Order Oqt.. ASME, 22 Lw Drive. Box 2300. Fad ed. NJ 07007-2300.(V,> C SF *7 QWP Z35Z-7 d Vq-t-\eS ZE-S" 4: S4155 -6 Aug 31 04 11:16a Oconee QR 86 V FORM NPV-1 [Back -Pg. 20f of CerUtUct 4-885-4001 p.5 a Holdoes Sarl NP. A92813 03 (13THRUI 6)L Design conditlor psi -* F or valve preasure class ANSr *300 11 (pr"esse v tu"q MIrl t. Cold workng pressure 740 psi at 104OF 10. Hydrostatic teat 112 pal DiP k dilk erertIat 820 ltt pressur- -pdO 11.nmems:_CERTWICA1ION OF DESIGN Design Speclielaln certifled by J. M. GWINN P.E.tate MA ne.no. 27 L51 Design Pport cortilbed y P.E. State RAg. no. _CERTIFICAlIE OF COMPUANCE We certify that the statements made In this report ere correst and tht thi puMp or valve confomS to the mles for comstrcton of ft ASME Code. 6efton UtI Division 1.NCertificateofAuthoristlonNo N-2882 11/10/04-- 08 /21/03 BNL INDUSTRIES, INC.Signed/r IU ~ (N Catrficate HNode CMERCAXTE OF INSffCTION I the undearsed, holding a valld commission issued by the Nationl Boad of Bdollr and Pressure Vessel Iasieci and th Stare or Province ot CONN. and mplyed by ONEBEACON AMERICA INS _of BOSTON, MASS have Inspected th pump, or valve. described hi this Date Report on 08/21/03 and stats trat to the best of my knowledge and belief, the Caetilleate Holder tes con-structad this pump, or valve, In acordance with the ASME Code, Section liU, DivisIon 1.By signing this certificate, neither te Inspector nor his eamployer makes soy warranty, expressed or impied, concenit the component described In this Date Report. Furthermo. net*wr the Inspector nor his employer shall be Iable In any marner for any personal kjury or property damage rea loss of kind arsing from or connected with hIs inspection. Da t aKeli. 5 gned /VW Gniaelons iV/ 7 7 A't C 7%'(C.t/A.arl. t.d WWI. l. M ndLnrwa entalM nd ate orpo. rnd ml ll) For menually operated valves only.(Cwp zssza Vi-iT'Sc. t.FIW- SPI t S) FORM NiS-2 OWNER'S REPr t- OR REPAIRS OR REPLACEMENTS As Required By The Prov. 'as Of The ASME Code Section XI__.-It 1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 1.a Date 09/23/04 Sheet I of 2 2a. Unit F 1 P2 r 3 r Shared (specify Units 3a. Work Order # 98621223.3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A 4. Identification of System Miscellaneous Mechanical Interferences Repair Organization Job #3b. NSM or MM # ON-23086 BM4 WP 235355 Class 3 5. (a) Applicable Construction Code ASME III NC 1989 Edition N/A Addenda, No Addenda /Code Cases N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)

Identific~ation of Comoonants Ranalred or RAnlacAd and Raniaramant Crnmnnnant-q 6.Column 1 Column 2 Column 3 Column 4 S Column 5 Col. 6 Column 7 Column 8 NatinalI ]ASME Code Manufacturer Board Other Year Repaired, Replaced, Stamped (yes.ame of Com.pnent ofu -1is hI ManuI maiiuuwrer seri .Umuera Number identification Built or Replacement or no)F Repaired o No r Replaced r Yes A P1ping Duke Power Company N/A N/A N/A 1974 -Replacement r Repaired r No rReplaced r Yes B -r Replacement r Repaired r.No rReplaced r Yes, c r Replacement r Repaired I-No r Replaced r Yes D r Replacement r Repalred r No r Replaced r Yes E r Replacement r Repaired 1 No r Replaced r Yes F r Replacement Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 81)2 in. x 11 in. (2) Information in items 1 through 3 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. DescriptIon of Work -Remove and re-Install Miscellaneous Mechanical Interferences

8. Test Conducted:

r Hydrostatic r Pneumatic W Nominal Operating Pressure rOther J Exempt Page 2 of 2 (Pressure _ _ psig Pressure psig Pressure _ psig Test Temp _ OF Test Temp .F Test Temp __ OF 9. Remarki Existing Miscellaneous Mechanical Interferences had to be removed to allow removal of old SG and Installation of the new 2B steam generator. This NIS-2 covers the welding for re-installing any piping associated with this mod. Applled Case Code N-416-1.(Applicable Manufacturers Data Records to be Attached)CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization No N se *o Expiration Date N/A Signed 6'L(P Date Z7 / (CERTIFICATE OF INSERVICE. INSPECTION I, the undersigned, holding a valid commision is ued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of _1_ and employed by J ' S CT have inspected the components described in this Owner's Report during the period o-4Y-0`)to -and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection.)k QDL. .Commissions tS3 > 3i, f ]T 61;ects Signature National Board, State, Providence and Endorsements Date ..-310- 0 5 Page 2 of 2 C FORM NIS-2 OWNER'S REPC f R REPAIRS OR REPLACEMENTS As Required By The Provo .,is Of The ASME Code Section Xl 47T 1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 la Date _0923I04 Sheet 1 of 2 2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 2a, Unit r 1 1o2 r3 3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp NIA Authorization No. WA Expiration Date N/A Shared (specify Units )3a. Work Order # .98621223 Repair Organization Job #3b. NSM or MM # ON-23086 BM4 WP23535B 4. Identification of System Misc. Mechanical Interferences Class 3 5. (a) Applicable Construction Code ASME ill ND 1989 Edition N/A Addenda, No Addenda /Code Cases N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)

6. Identification of Components Repaired or Replaced and Replacement Components Column 1 Column 2 Column3 column 4 Column 5 Col. 6 Column 7 Column 8 l ~~~~Natinl SECd l Manufacturer Board Other Year Repaired, Replaced, Stamped (yes.Name of Car-n-e I .Nae O" umbanufaCu.iuer eru.a: .auuIr Number uidenifealuln Buifi or Repiacemeni or no)P Repaired P No Hanger/Support r Replaced rYes A 2-57-0-1481A-H21 Duke Power Company. WA N/A N/A 1974 r Replacement.v RepaIred rv No Hanger/Support rReplaced r Yes B 2-57-0-1481A-H22 Duke Power Company N/A N/A N/A 1974 r Replacement iP Repaired v No Hanger/Support r Replaced r Yes C 2-57-0-1481A-H20 Duke Power Company N/A N/A N/A 1974 r Replacement P Repaired r No Hanger/Support r Replaced r Yes D 2-57-01481A-H23 Duke Power Company NWA N/A WA_1974 _ _ Replacement rvo Repaired rv No Hanger/Support r Replaced r Yes E 2-57-0-1481A-H19 Duke Power Company WA N/A NIA 1974 r Replacement Pv Repaired P No Hanger/Support F Replaced r Yes F 2-57-0-1481A-H6 Duke Power Company NWA N/A N/A 1974 F Replacement

-Page 1 of 2 Form NIS-2 (Back)Sheet 2 of 2 NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 1 1 in. (2) Information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Remove/renlace SG 2B misc. mech. Interferences In support of SG Replacement.

8. Test Conducted:

r Hydrostatic F Pneumatic r Nominal Operating Pressure r Other iv Exempt Pressure psig Test Temp OF Pressure psig Test Temp OF Pressure psig Test Temp _ _ OF 5. (a) Applicable Construction Code ASME IlIl ND 1989 Edition WA Addenda, No Addenda -/ode Case!9. Remark. Hangers were removed for the removal of the 2B SG and replaced after Installation of the new replacement steam generator.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.Type Code Symbol Stamp WA Certificate of Authorization No. MIA :5 &R-k-k Expiration Date N/A Signed 7 ? Date '//3c./ i;PCERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commisionrsgied by the National Board of Boiler and Pr ssure Vessel Inspectors and the State or Providence of 4J (aand employed by Z2 Q have inspected the components described in this Owner's Report during the period .togI79q; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. _ __Commissions Me3 5, X, , inspectols SignatureC National Board, State, Providence and Endorsements Date q Page 2 of 2 FORM NIS-2 OWNER'S REPr Gi 'OR REPAIRS OR REPLACEMENTS As Required By The Prosv ns Of The ASME Code Section Xi I-0 1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 1.a Date _09/23/04 Sheet 1 of 2 2a. Unit r 1 iv 2 r3 r Shared (specify Units 3a. Work Order # 98621223 Repair Organization Job #3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A 3b. NSM or MM # ON-23086 BM4 WP23535B 4. Identification of System Mlsc. Mechanical Interferences Class 3 5. (a) Applicable Construction Code ASME IlIl ND 1989 Edition N/A Addenda, No Addenda /Code Cases N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)

Identification of Components Repaired or Replaced and Replacement Components 6.Column 1I l Column 2 [ Column 3 ] In Column 5 l Col. 6 Mu 3 C7 n Column 8 National ASME Code Manufacturer Board Other Year Repaired, Replaced, Stamped (yes Namel o Colimin Name ui Manulauiurer 0euia1 I-umbeIM N umb,1EdIULI IUr BUIII~duII Dulll we wiae; lorw 1v Repaired Wo No Hanger/Support r Replaced r Yes A 2-57-0-1481A-H7 Duke Power Company N/A N/A N/A 1974 r Replacement iv Repaired iv No Hanger/Support r Replaced F Yes B 2-574-1481A-H9 Duke Power Company N/A N/A N/A 1974 r Replacement iv Repaired 1v No Hanger/Support I Replaced r Yes C 2-57-0-1481A-H1O Duke Power Company N/A N/A N/A 1974 r Replacement iv Repaired Wo No Hanger/Support r Replaced r Yes D 2-57-0-1481A-H17 Duke Power Company N/A N/A N/A 1974 r Replacement iv Repaired Wo No Hanger/Support .Replaced r Yes E 2-57-0-1481A-H25 Duke Power Company N/A A N/A 1974 r Replacement We Repaired P No Hanger/Support r Replaced r Yes F 2-57-0-1481A-H15 Duke Power Company N/A N/A N/A 1974 r Replacement Page 1 of 2 Form N1IS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets Is recorded at the top of .-this form.7. Description of Work Remove/rePlace SG 2B misc. mech. Interferences In support of SG RePlacement. Sheet 2 of 2 8. Test Conducted: r Hydrostatic F Pneumatic r Nominal Operating Pressure r Other W Exempt Pressure _ _ psig Pressure _ _ psig Pressure psig Test Temp _ F Test Temp OF Test Temp OF 9. Remark: Hangers were removed for the removal of the 213 SG and replaced after Installation of the new replacement steam generator.(Applicable Manufacturers Data Records to be Attached)CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.Type Code Symbol Stamp NWA Certificate of Authorization No. 15(,pv Svss,&o, Expiration Date KUA Signed A / 5 Date 9 3 /Osf CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commisi on issed by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of ___ and employed by lEC have inspected the components described in this Owner's Report during the period.2-a Y to J>^ , and state that to the best of my knowledge-and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Cnmmissinns 2L ST 9 A) Z-InspeI s Signature Date 0 National Board, Statee, Providence and Endorsements Page 2 of 2 l r FORM NIS-2 OWNER'S REPr k OR REPAIRS OR REPLACEMENTS As Required By The Pros as Of The ASME Code Section Xi 1. Owner -Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 1.a Date -0923104 Sheet 1 of 2 2a. Unit r 1 W 2 r3 3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp WA Authorization No. N/A Expiration Date WA Shared (specify Units _3a. Work Order # 98621223 Repair Organization Job #3b. NSM or MM # ON-23086 BM4 WP23535B 4. Identification of System Misc. Mechanical Interferences Class 3 5. (a) Applicable Construction Code ASME III ND 1989 Edition N/A Addenda, No Addenda /Code Cases N/A (b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)
6. Identification of Components Repaired or Replaced and Replacement Components Column 1 l Column 2 r Column 3 Column 4 Column 5 Col. 6 Column7 Column National ASME Code Manufacturer Board Other Year Repaired, Replaced, Stamped (yes rv Repaired r No Hanger/Support r Replaced r Yes A 2-57-0-1481A-H14 Duke Power Company N/A N/A N/A 1974 r Replacement i Repaired F No Hanger/Support r Replaced r Yes B 2-57-0-1481A-H16 Duke Power Company N/A WA NI_1974 r Replacement Fv Repaired F No Hanger/Support r Replaced r Yes C 2-57-0-1481A-H11 Duke Power Company N/A WA WA 1974 r Replacement Fv Repaired 17 No Hanger/Support 1 Replaced r Ye D 2-57-0-1481A-H12 Duke Power Company N/A N/A N/A1974 r Replacement F Repaired Fv No Hanger/Support

.Replaced r Yes E 2-57-0-1481A-H13 Duke Power Company N/A N/A N/A 1974 r Replacement F Repaired F; No Hanger/Support r Replaced m ens F 2-57-0-14S1A-H26 Duke Power Company WA WA N/A 1974 Replacement -_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ -P a g e 1 o f 2 Form INIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information in items 1 through 6 on this report is included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of.-this form.7. Description of Work Remove/reelace SG 2B misc. mech. Interferences In support of SG Replacement.

8. Test Conducted:

r Hydrostatic r Pneumatic r Nominal Operating Pressure r Other 17 Exempt Sheet 2 of 2 (Pressure _ _ psig Pressure _ _ psig Pressure _ _psig Test Temp _ OF Test Temp _ _ OF Test Temp .F 9. Remark: Hangers were removed for the removal of the 213 SG and replaced after Installation -8 &16- --.. -&---WI LJOU IIVW IFZ MUCIII0116 OLOCIII WaVICIO&WI. -(Applicable Manufacturers Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.Type Code Symbol Stamp NIA Certificate of Authorization Nq6.A Expiration Date N/A Signed ' Date CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commisioQ i.s ed by the National Board of Boiler and Pr ssure Vessel Inspectors and the State or Providence of -____ and employed by 5 S CX have Inspected the components described in this Owner's Report during the period a 3l b to ; and state that to the best of my knowledge and telief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Ownerst Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arisino oroconnected with this Inspection. \ 0 _ ~~~Co~m~missionns /)Jd3 ^lifir;6tor-A Signature National Board, Stat', Prov'idence and Endorsement:s Date !Wo Page 2 of 2 FORM NIS-2 OWNER'S REP' 'OR REPAIRS OR REPLACEMENTS As Required By The Prov. .ns Of The ASME Code Section Xi o-1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 1.a Date 6114104 Sheet 1 of 2 2a. Unit r 1 W 2 r3 r Shared (specify Units 3a. Work Order # 98621223 Repair Organization Job #3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp NIA Authorization No. N/A Expiration Date NIA 3b. NSM or MM # ON-23086 BM4 WP23535B 4. Identification of System Misc. Mechanical Interferences Class 3 5. (a) Applicable Construction Code ASME IlIl ND 1989 Edition N/A Addenda, No Addenda /Code Cases N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)
6. Identification of Components Repaired or Replaced and Replceent Components

_____ _______Column 1 Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 7 Column 8 National ASME Code Manufacturer Board Other Year Repaired, Replaced, Stamped (yes Name nf (penmnnnnt Noma u -aI Number N !e!ationa1A CoeO Se ~ria! Iila M1,mhma. MMa.II .rv Repaired 17 No Hanger/Support r Replaced r Yes A 2-57-0-1481A-H18 Duke Power Company WA N/A N/A 1974 I Replacement W-Repaired P' No Hanger/Support F Replaced r Yes B 2-57-0-1481A-H5 Duke Power Company NA WNA NWA 1974 r Replacement r Repalred r No r Replaced r Yes C rReplacement r Repalred r No r Replaced r Yes D r Replacement rRepaired r No rReplaced r Yes E rReplacement r-Repaired rNo rReplaced r Yes F r Replacement Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of. -this form.7. Description of Work Removelreplace SG 2B mIsc. mech. Interferences In support of SG Replacement.

8. Test Conducted:

r Hydrostatic F Pneumatic F Nominal Operating Pressure r Other P Exempt Sheet 2 of 2 Pressure _ _ psig Pressure psig Pressure psig Test Temp .OF Test Temp 'F Test Temp OF 9. Remark. _Hanners were removed for the removal of the 2E1 SG and replaced after Installation of the new replacement steam generator.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xi.Type Code Symbol Stamp NWA Certificate of Authorization No. N/A sLa&zgA FkS4L Expiration Date NA Signed __ Date________ CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commision iFsued by the National Board of Boiler a dPr u essel Inspectors and the State or Providence of J C and employed byy have inspected the components described in this Owner's Re¶,6rt during the period totf37L; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Ccde, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. ...Commissions , , 1 , 53, A, ._Dat neptvr's Signature Date i-°D National Board, State, Providence and Endorsements Page 2 of 2 FORM NIS-2 OWNER'S REpr 7 0R REPAIRS OR REPLACEMENTS As Required By The Pros Iv s Of The ASME Code Section Xl t.--- __ -In.1. owner Duue Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 La Liate Vw14131 Sheet 1 of 4 2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 2a. Unit r 1 W 2 r 3 r Shared (specify Units 3a. Work Order # WO 98648846/98540919 (Tend. Removal/Reolt) Repair Organization Job #3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp NWA Authorization No. N/A Expiration Date N/A 3b. NSM or MM # ON-23086 AS9 WP 21551 (Tendon Removal)WP 23551 (Tendon Renlacement)

4. Identification of System Reactor Containment Class CC 5. (a) Applicable Construction Code ASME ill Div. 2 1992 Edition N/A Addenda, 1992 /Code Cases N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class Mc and cc and their supports.)
6. Identification of Components Repaired or Replaced and Replacement Components Column 1 Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 j Column 8_t iuuuaur riINational

.ASME Code Manufacturer Board Other Year Repaired, Replaced, Stamped (yes NaE o o ~ e : N m o Mnui a; , , T r u maNumb e r I de nk:o u ::o lcmn,no See Attached rRplo vN Tabie A For rPplrdr No Affected Tendon 1v Replaced r Yes A Tendons Duke Power Company Number NIA N/A 1974 F Replacement see AttacnaRepalred Table B For- Prea~e No Affected Tendon F Replaced r Yes B Tendons Duke Power Company Number N/A N/A 2004 P Replacement r Repaired F No r Replaced r Yes C .r Replacement _r Repaired r No r Replaced r Yes D _r Replacement r Repaired r No r Replaced r Yes E _ _ Replacement r Repaired r No r Replaced r Yes F r Replacement Page 1 of 2 Form 1NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information in items 1 through 6 on this report is included on each sheet, and (3) each sheet Is numbered and the number of sheets is recorded at the top of ---this form.7. Description of Work Removal/replacement of tendons for constructIon opening.8. Test Conducted: r Hydrostatic r Pneumatic F Nominal Operating Pressure r Other 1F Exempt Pressure ; psig Pressure psig Pressure psig Test Temp _ F Test Temp OF Test Temp °F 9. Remarki Selected tendons were removed for Installation cf construction opening. Closure of construction opening required tendon replacement. Table A lists tendons that were removed and Table B documents final configuration of Installed tendons per this modification.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xi.Type Code Symbol Stamp N/A Certificate of Authorization N,: NIA SEs:&Szmb Expiration Date N/A Signed r Date cZ 3/O'f CLET I ICUATIt UOF INZSERVIU INSPEU I IUN 1, the undersigned, holding a valid commision issed by the National Board of Boiler and Pros ure Vessel Inspectors and the State or Providence of AJLQ__ and employed by 1 have inspected the components described in this Owner's Report during the period elf3099 to 2 E and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arisn from or connected with this inspection. aCommissions VCL JS3 A) 227 Inspec`c~s Signature National Board, State, Providence and Endorsements Date 930Y I Page 2 of 4 I Ar-ONS 2 TENDON' I MOVED DURING 2EOC20 I I IIaDI ta nP22/04 I.e Power Comoany_i I-a hilr-h C- S 1.E', -s I I-- 2 f4 I 1 I I I_ _. .I_ __ I I _ I I 2. Plant Oconee Nuclear Station I II I I I I Addres 780 Rochester Hwy. Senec , S.C. 29672 _ =, I __I I _ 3a. Work OrderWO 9864 8846!1840919 8 ren L e w l[eon 3. Work Performed By Duke Power Comnpany I Repair Oranization Job #Address 526S. Church StCharlot eNC 2820 1006 I I I i I Type Code Symo IStam NiA Authorization No. NA 3b. NSM or MM # ON-23086 AS9 WP 21551 (Tendon R I I I I I I1 1WP 23551 (Tend~on Reoloacemen

4. Identificaton of System Reactor nt~lnvmet Class S. (a) Applicable Construction Code ASME III Div. 2 19.Edition N/A Addenda,1 Jod CasesWA .(b) Apooicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 thrwugh 1992 Addenda for Class MC and cc and their supports.)

I 1 , 6. Identification of Compents Repaired or Replaced and Replacement Components £TABLE B ONS 2 TENDONS P 'ACED DURING 2EOC20 it T 5;mr JDuke Power Compiyn-r A "SW -uw7N04 Addr.e 5 Ithre.h SheeLU COhavMfrq. NCH 2S2f0i.1-% I I I I I_ Siheet 4 of 4 2. Plant Ocnee Nudeer Stion I_Addre 7800 Roctehr Senec, S.C. 29672 2a. Unit I I I _ 9 end =I I -3a. Work Order# WO 9i68846S540919 ITend Ie vaVReit)3. Work Performed By Duke Power Company Repair Organization Job #Address 526 S. Church Silte Charlott NC 28201-100 i i i T Code bol Stamp WA Auhorlzation No. NA3b. NSM or MM # -23086 AS9 WP 21551 tend _ movf iT I I IWP2355lAfend_ ReoIe.Identt _emRorContalnmtent Class _CC 1 1 5.(a)ApplicableConstonCodeASMEIIIDlv.2 1992 Edilon NWA Addenda,19 /Co (b) Applicable Edition of Section Xl Utilized for Repairs or Replacerents 1989, No Addend(992 through 1992 Addenda for Class MC and co aThei 24888 IW71 2 _ 45 I I 7 _2 5: B. Ident~ifiation of ComPortents Repaired or Repbaced adRepiacemen Coponents lTendon MGM ho emtiX Fiel Head Wire Tendon HetShop Head: ~ Fhied Head Wire Number Cohide uis Code Had Numiber Heat No. Number Co e t Numberod it Numnber itM No.= .2 42H46 TX16 183746 1WO 237486 42H47 1X2. t374t 1 XZ t374S 421-14 1 13748 13724 3 = 2 _ _ 421149 Tx16 13748 TW2 24685 X62035 X663 23V29 TWs5 248 TW7 24685 XW05 42Hs5 TX1771 13746 TW62 24685 X68Os3 23V30 TW26 24885 TW73 24885 ._7_ 42H-t 17 13748 TW10 24885 x6e0m3 34Vt TW43 2246s 421-152 TX187 13746 TW4 124685 xe6s3 3V Ts3 265 TW79 24685 .2s3r1 81 1S74U TW61 24685 x~em0 34V3 TW3v 24685 TW25 24885 X66tJ1t 42HU5 TX11 13746 TWB 248t3 X66053 34V4 13748 TW41 24885 42-158 X1 13746 TW71 24685 X60W3 L34V5 ITW421 24685 HTX2 13746 lil42Hss lTX1811 1374B gTX64 137U4 I xe60s3 34V8 TW361 1468 TWS7 2468l5 l 1 421157 TX191 13746 TW65 24685 l x l13W7 1374 TW41 24sss 421160 TX1 13748 TW71 24885 XI x 53 L34V8 1374 jW 48 X68051 42118 TX191 13748 TWtS7 2348 X6_0_3l 34vs1 _3748 TW48 2u85 x660s 42H60 FTX 13748 _Twit 24685 l X6_ 3 1 34V10 18 X66053 421-183 1 24885 ITW39 34V 12 92X16 13746 IT)(2441 13746_ X66t631 l se 132468 ITX2061 13748 l MMt!5 34V-1 13746 l13748 X6603 42Hs34 TX22W1 13748 1 13746 l XOM1 134V4 Tx3 13746 Tx2 13748 X66053 42116 85 13746 TX231 13746 Il 34v15 TX89 13746 TX21 13748 X66053 ____l F_l_34Vt ITX2 1fXd U40 1 AZX4, 37j4v ADDOU^ f FORM NIS-2 OWNER'S REPO- R REPAIRS OR REPLACEMENTS As Required By The Pro"' Is Of The ASME Code Section XI (-, 1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 l.a Date 09/23/04 Sheet 1 of 2 2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 2a. Unit r 1 F72 r-3 r Shared (specify Units)3a. Work Order # 98644159 & 98540909 (Concrete RemJRolt)Repair Organization Job #3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A 3b. NSM or MM # ON-23086 AS9 WP 21550 (concJrebar removal)WP 23550 (concJrebar renlacemt)

4. Identification of System Containment Class CC 5. (a) Applicable Construction Code per SGRP-SPEC-C-003 19 W/A Edition N/A Addenda, N/A /Code Cases N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)
6. Identification of Components Repaired or Replaced and Reiacement Components Column 1 Column 2 _ Column 4 Column5 r Col. 6 Column 7 Column 8-Manufacturer Board Other Year Repalred, Replaced, Stamped (yes Name of Component Name of Mantdaptuire r er1 Nationalu:or 10ASmer Code No Name ---- S------- M-her Nuimber ~~.I I-. Repaired rV No Concrete (Removed F Repaied for Construction Replaced r Yes A Opening) Duke Power Company N/A N/A N/A 1974 r Replacement Concrete (Replaced r Repalred 17 No for Restoring r Replaced r Yes B Containment)

Duke Power Company N/A N/A N/A 2004 ro Replacement .Pw Repaired 1 No r Replaced r Yes C Rebar Duke Power Company N/A N/A NA 1974- r Replacement r Repalred r No r Replaced r Yes D .r Replacement F Repalred r No r Replaced m r Yes E _ _ _ _Replacement r Repaired r No 1r Replaced r Yes F ., Replacement Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information in items 1 through 3 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work: Creation and closure of construction opening for removing old RVHAISG/s and Installing new.8. Test Conducted: r Hydrostatic r Pneumatic r Nominal Operating Pressure rv Other r Exempt (Pressure 59.921 psig Pressure psig Pressure psig Test Temp 84 OF Test Temp OF Test Temp _ _ 0 F 9. Remark: Work Involved removing concrete. rebar and liner plate to create the construction opening above the Unit 2 equlement hatch. After the RVH and two SGs were replaced the old4hwa. I i I r-plate was re-Installed, rebar re-installed and new concrete placed to re-establish containment. <Z'13 1/3q'eylf 2i41A q-3 0-OL/Testina was accomollshed with the integrated lealk rate test.Pressure and temperature numbers came from the Unit 2 Containment Integrated Leakage Test Report, reading # 248.(Applicable Manufacturer's Dala Records to be Attached)CERTIFIC N/A 1974 We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xi.Type Code Symbol Stamp WA Certificate of Authorization No. WA , +/-wg Expiration Date N/A Signed Date tf CERTIFICATE OF INSERVICEE INSPECTION I, the undersigned, holding a valid commision isgued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of l --_ and -employed by have inspected the components described In this Owner's Report during the period d ~5'a i and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arisingfron or connected with this inspection. Commissions A ., 4 z Qsinectofs Signature National Board, State, Providence and Endorsemenls Date 9z30 t 0Y Page 2 of 2 C FORM NIS-2 OWNER'S REP( ' OR REPAIRS OR REPLACEMENTS As Required By The Provi..4ns Of The ASME Code Section Xi 1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006

2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 1.a Date 09/30/04 Sheet 1 of 2 2a. Unit F 1 172 r 3 r Shared (specify Units)3a. Work Order # 98540994 Repair Organization Job #3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. NWA Expiration Date N/A 3b. NSM or MM # ON-23086 AS9 WP 23555 4. Identification of System Containment Class MC 5. (a) Applicable Construction Code ASME Section VIII 1998 Edition N/A Addenda, 98 Addenda /Code Cases Ni/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)
6. Identification of Components Rep ired or Replaced and Rep ment Components Column I Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8C AMa f.trr -.1 National ASMECod Manufacturer Board Other Year Repaired, Replaced, Stamped (yes Nam of Comwonr; .um il ianuia riNumer Number identification Buiit or Replacement or no)_ Repalred Wo No Containment Liner r Replaced r Yes A Plate Duke Power Company N/A NA N/A 1974 r Replacement r Repaired r No r Replaced r Yes B F Replacement r Repalred r No r Replaced r Yes c r Replacement r Repalred rNo r Replaced rYes D _ rReplacement F Repalred r No rReplaced FYes E _ Replacement F Repaired r No rReplaced r Yes F rReplacement Page 1 of 2 Form NIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information in items 1 through 43 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Creation of construction opening for- removing old RVHA/SGIs and Installina new.8. Test Conducted:

r Hydrostatic r Pneumatic F Nominal Operating Pressure F Other r Exempt (Pressure _ psig Pressure; psig Pressure -psig Test Temp _ _ 'F Test Temp -__F Test Temp _ OF 9. Remark. Work Involves cutting the liner plate above the equipment hatch for construction opening. After moving new RVHA and S/Gs Into containment the cut out liner plate was then welded back In place. Testing Is accomplished with the Integrated leak rate test after plate Is re-welded, concrete repilaced and tendons replaced.Pressue and temperature numbers came from the Unit 2 Containment Integrated 'Leakaae test Renort. readina # 248.(Applicable Manufacturer's Dala Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization No. N/A '56F-- et Expiration Date NWA Signed /W -AWA r-S Date : 3 /0 '7'(GER1 I IrI'A I ijF INItRVIGE: INSPtCI IU I, the undersigned, holding a valid commision issued by the National Board of Boiler and, RP sure Vessel Inspectors and the State or Providence of .and employed by -gna have inspected the components described in this Owner's Report during the'period olgalit6 to S t7VL; and state that to the best of my knowledge and belief, the Owner has performed examinations and'taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions A) 73 A). <ldspd~ers Signature Date q~ ;3c --0 National Board, State, Providence and Endorsements Page 2 of 2 A, -C f FORM NIS-2 OWNER'S REPP IJR REPAIRS OR REPLACEMENTS As Required By The Pt ., Of The ASME Code Section Xl 1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 1.a Date _09/22/04 Sheet 1_ of 9 2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 2a. Unit r 1 7 2 r3 r Shared (specify Units 3a. Work Order # 98624546(Removal). 98617114(Renlacement) Repair Organization Job #3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A 3b. NSM or MM # ON-23112 AM2 WP 21535H (Removal)WP 23535H (Replacement)

4. Identification of System Reactor Coolant System Class I 5. (a) Applicable Construction Code ASME III 1989 Edition N/A Addenda, No Addenda /Code Cases N/A (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.)
6. Identification of Components Repaired or Replaced and Rep acement Components Column 1 Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8 National S od Manufacturer oa Other Year Repaired, Replaced.

Stamped (ves Name Of Component Name of Manufacturer Serial Number Number Identification Built or Replacement or no)r Repalred r No Babcock & Wilcox Co. Replaced r Yes A Reactor Vessel Head Mt. Vernon, Indiana 620-0004-51-52 N-105 N/A 1970 r Replacement r Repaired r No Babcock & Wilcox r Replaced W Yes B Reactor Vessel Head Canada 068S-02 209 N/A 2003 17 Replacement r Repalred r No r Replaced r Yes C r Replacement r RepaIred F No r Replaced r Yes D _r Replacement F Repaired r No r Replaced r Yes E Or Replacement r Repaired r No r Replaced F Yes F r Replacement Form NIS-2 (Back)Sheet 2 of 9 NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work Replaced Unit 2 Reactor Vessel Head 8. Test Conducted: r Hydrostatic r Pneumatic 1;7 Nominal Operating Pressure r Other r Exempt Pressure psig Test Temp OF Pressure psig Test Temp OF Pressure psig Test Temp _F 9. Remarki Old reactor vessel head and the reactor vessel were certified under one N-1A form (National Board N-105). Only the reactor vessel head was replaced durIng ONS outage 2EOC20. CRDMs were removed from the old reactor vessel head and Installed on the new reactor vessel head In same core locations. Applied Code Case N-416-1.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the riles of the ASME Code, Section Xl.Type Code Symbol Stamp NIA Certificate of Authorization No N/A o5$&4 --k Expiration Date N/A Signed A -/ 7 Date CERTIFICATE OF INSERVICE INSPECTION b 1 I, the undersigned, holding a valid commision i sj ed by the National Board of Boiler and Pses e Vessel Inspectors and the State or Providence of / ____and employed by have inspected the components described in this Ownees Report during the period 5-/O -eq to 8- O (4/: and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Ccde, Section Xl.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arisi om or connected with this inspection. OfJ .4 ICommissions i lc :3 1 -7ZI Ipe 's Signature National Board, State, Providence and Endorsements Date q -ag ) to S62o.ooo4L. FORM?~ N-IA AMANUFACTURERS'EDATA REPORT FOR NUCLEAR VESSELS* .Alternate Form for Single Chamber Completely Shop-Fabricated Vessels Only As required by the Pr~visions of the ASNIE Code Rules 1. Manufactutcd by Babcock & Wilcox 'Co. Mt. Vro, Indiana ( O(erne and address of martufacturer)

2. Manufactured for DuePwrC.conte Nuc~eaf PwerlStation-DukePowe Co.our nay, ou hafoli.na (Name and addreesa o Purchaser)
  • 3. Type Reactor Vessel No. (62o-ooo'-51,-52

_ ) Nat!. Bd. No. .N4105 .Yeat Built, 1970'.04fler. or Vert.) (Wtro.Serial) -(Stt-t4 4- ..flti*3a. Applicable ASME Code: Section Ill, liuition 1965 -.Addenda date Summer-i967 ,Case No. MS-67 Ao8-64m2 168 3/8'ID___4. Shell: Maeil1322 T.8,0 Thk.8*. Allow 0 I. Dim681 3182'ID Length...@FtJ 13/16"t (XInd &Spec. Mo.) (Min. of rangespecified) S. Seams: Long none H.T.9 X.R. -Efficiency_______7 (11 class B)wethbtutt welded H.T.1-yes X.R .ves No. of C Srxe 6. Hleads: (a) Miatcria See Supplemental Sheet #2for Item #6_____Location. crow" Knuckle Ellip.tical Conical liemlsphericat Slat .'Iid. to Pressure crop, bottom. ends) Thickness Radius Radius Ratio Apex Angle Radius Diameter (Convex or Concave)* aj.. 6.625" -__ 8 " concave W b bottom 5.000' I_____87R concave IfU temorable. bolts useA5'4o-P6-B2-3-133-2 L31~45.000 T.TTPt'ia 60 (lUaterial. Spec. No.. T.S..Site. lluthrb. (Describe or Attach Sketch)Otarpy imrpact .30. ft-lb lld10t0 * @O 0 F_Pneuetw-o Test 7.DCSign~pressure'2 2?5 00.... psi at 650 ".,...F. at temp. of ko oF. -Gembreie-Press.32i... Si.S. Safety or Relief Valve Outlets: Number none Size._______Location -9. Nozzles: Purpose (.Inlet. Re inforcement nlow OutletC. Dra in) Number Diem, or Size T'ype Material Thickness material Attached£ Len al-hh-f2or Tt~emn9_______ to. Inspection Mfanholes, No. none size -Location -(Openings: Handholcs. No. none size -Location -Threaded, No nn size -Location -11. Supports-Skirt ..~ Lugs -Legs -Other Attached Welded to bottom head ays.,r No) I-Tunber)- .Drbe) (where & Ut w)12.Remar'ks:.A.- Class A reactor Vessel. Contents: water.2B....-St-p Slipi lementgil Shep't #2 for addi ti anal remarks,-'If Poatweld Heat-Treated. S LIst ether inmtera or external pressure wtithcoincident temperature when applicable. We certify that the statements made in this report are correct and that this nuclear vessel conforms to the ruales of construe.Zion of the ASME Code. Section Ill..Date, March 24~ 1971 Signed Babcock & Wilcox Co.rng.~u tManulacturet) oierngW D Certificate of Authorization Expires April 10, 1972 C m oet*ngineerinM~ CERTIFICATION 10F DESIGN Deinifrain-.u tBabcock & Wilcox Co.. Barberton,, Ohio htrees analyola report on fie at Babcock & Wilcox Co. Barberton., Ohio Doeeln specifications certified by (Ti ennf J_ Sniyder .Prof. Eng. ye ...5stte V..& Reg. No. 2235., Stress analyalareport certified by James P. Butti Prof. Eng. Ye S Stae Ohio Rag. No. E-29i1O CERTIFICATE OF SHOP INSPECTION VESSEL MADE BY Babcock & Wilcox Co. at Mt. Vernon, Indiana L the tmdearstgnd. holdlng a vaIId commiatssion Issued by the Nationat Board of Batter end Pressure Veeselinaptetors and/or the State or Province of eand employed by Hartford S. B. I. & I. Co. ot-Hartford, Connecticut have inspected the pressure veined described In this manufacturer's date report on October 17 ,,70 .and stats that to the beet of my knowledge and belief, the neanufecturer has constructed this pressure vessel In, accordance with the ASMdE Code Section IIIt.By aigninC this certificate neither the Inspector nor his employer makes any warranty. expressed at Implied, concerning tie pressure vessel described In this manufactureres date report. Furthen-ors. neither the Inspector nor his employer thall be liable In any manner for any personal Injury o r opetdawlev e or a losa of any W.p arlaing from or connected with this inspection. Date "Marc -to ,...2,L h'. -X, Al/ L&, ; ,r~L Commissions NB #3864 Inspectqr-o SICnaturd National Board. State. Po.ince and No. SHEET 2 o- 2FP 4-'F L A 2 CP-SUPPLEMENTAL SHEET-FORIM N-1A MANUFACTURERS DATA REPORT FOR NUCLEAR VESSELS Alternate Formn for Single Chamber CoompletelyShop-Fabricatcd Vessels Only As required by the Provisions of the ASME Code Rules 1. MIanufactuetd by Babcock & Wilcox Co. Mt. Vernon, Indiana cN&onee Weufac T'Fwer Station 2. Manufactured fot Duke Power Co. Courtnay, South Carolina (Name and eddress ot Pureha ser)3. Tye Reactor Vessel No. (_620-0004-51-52 ) att.d.No. N-105 Year Built__97j" Vert.) (Le.Se.rTa) (Stat. & Stati No.)6.(a) Top head material: A533-B-1-1339-2. T.S. 80,000 and A508-64-2-:L332-2 T.S. 80,000.6.(b) Bottom head: A302-B-1339. T.S. 80,000 and A508-64-2-1332-2.T.'., 80,000.90 Nozzles:*Purpose (Inlet.Outlet, Dtran)core flood safe end monitor inlet outlet instrument CRMH. body CRMH. adapter M .ai:T ( -Number Dican.. or Size 2 25"OD 2 2 , D.315'D 4 48.toD%27 75-110D 52 L.035"OD_69 4.025'gUD-69 4.-60o---w W. .1 o Typ-weld weld weld 1.weld,..weld weld weld weld I aterial A50o8-6 1 4-2-1332-2 SA 336-F8M:SA376 TP3o4 A~o&6 4-2l132--SB167'A1-82 F304f IRe intfo cement Tlickness Material 6.164'l integral-1.54" integral-.270" integral 11.625" integral 137t Is integral 6 19 integral.-7' integral How Attached welded iwelded welded welded welded welded welded welded -Remarks C. Vessel-clad internally with 1/8" minimum SA-371 ER308L except a band in tihe guide lug area of lower shellattachment welds of control rod housings and attachment welds of instrumentation nozzles, which is inconel ER-NICRFE-3. D. Shell flange material: A506-64-2-1332-2. T.S. 80,000._ Shell flange size: 165 3/8"ID x 200"0D x 22"' flange thickness. Ilosure head flange material: A508-64-2-1332-2. T.S. 80,000.Closure head flange size: 152 3/8"ID x 200"OD x 30" flange thickness. As Required by the Provisions of the ASME Code, Section III Not to Exceed One Day's Production) Pg. 1 of 3_, _ _-1. Manufactured and certified by Babcock & Wilcox Canada, 581 Coronation Boulevard, Cambridge, Ontario N1 R 5V3 2.Mar-'ictured for Duke Energy Coroporation, 13225 Hagers Ferry Road, Huntersville, NC, 28078-8985 fn of installation Oconee Nuclear Power Plant Unit 2, South Carolina 4. iype, 068SE001 See Ust #1 See List #1 -2003 (drawing no.) Imati spe na.) ttensi Sbength) (ICRI New bhl:)S. ASME Code, Section , Division 1: 1989 No Addenda (edion) (adenda aate.S. Fabricated in accordance with CoUst. Spec. (Div. 2 only) _(no)I (See Note #1)(class)Revision ,_. w _ _s , (Code Gas. no.)Date 7. Remarks: JSW N-2 form for head forging is attached.I. t.mm.dsg 2-.fI LI'.W-50 14.1. Nom. Hlin. design -hickness (n.) See List #2 thickness (in.) See List #2 Dia. ID (ft & in.)1 When aoolicnhle. Certificate Holders' nntA Rpnnrts are attndhel fnr encdh ihtm nf this ronrt Length overall 12'-8 7116" _ (ft& in.)National Part or Appurtenance Board No.Serial Number In Numerical Order I) 0688-02 209 a)2) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _3-) _______________________

4) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _4),..- .. ._ .(26)-(27)(28)(29)(30)(31)(32)(33)(34)(35)(36)(37)(38)(39)(40)(41)(42).(43)*(44)(45)(46)(47)(48)(49)(50)National Part or Appurtenance Board No.Serial Number In Numerical Order_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _- -.__ _ _ _ _ _ _ _ _ _ _ _ _ _AF11_ ...----At temp. 709F Designpressure 2500 Psig. Temp. 600 F Hydro. -test pressure 3125 psig Min.Supplemental information in the form of lists, sketches, or drawings may be provided (1) size is 8 V'2 X 11, (2) information in items 2 and 3 on this Data Report is included on each sheet, (3) each sheet is numbered and the number of sheets is recorded on dte top of this form.G.1aI.VRV6svaaadO

.-... .V * .W --' SiY. -2i".g., ,I>. t-I .Certificate Hlder's Serial Nos. 068S-02 through E CERTIFICATION OF DESIGN'*specification certified by M. C. Keck P.E. state NC Reg. No. 18367 Province Design report* certified by L Vizi P.E.State Ont Reg. No. 4824420 (vinen WpUcabW)CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this (these.-) Reactor Vessel Head Conforms to the rules of construction of the ASME Code, Section III, Division 1.NPT Certificate of Authorization No. N-2791 Expires JanuaryLZ4 2004 Date J_'(" Name Babcock & Wilcox Canada Signed (NFT Certffrwe Hoider)CERTiFicA:rEOFINSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Ontado and employed by Technical Standards & of Onta(io have inspected these Rems described In this Dats Report'on and state that to the Best of my knowledge and belief, the Certificate Holder has fabricated these parts or appurtenances In accordance with the ASME Cole, Section Ili, Division 1.Each part listed has been authorized for stamping on the date shown above.3y signing M certificate, neither the Inspector nor his employer makes. any waiTanty. expressed or.implied" concerning the equipment described In this Data Repc,, .irthermoreneithertheinspectornorhisemployershaliberfableinanymannerforany-personatinjury-orproortydama4e4)rfossQfanykindarising-connected with this inspection. jr-_:S_,W-:k A"S ---TZ Commissions

G. Anala ffT)RW10=UNosso If b NUULLtAR PARTS AND APPURTENANCES*

.7 As Required by the Provisions of the ASME Code, Section 1-Not to Exceed One Day's Production Pg. 3 ofI %- --1 I'z.1 N Certificate Holders Serial Nos National Board Nos 068S-02 through 209 through dactured and certified by Babcock & Wilcox Canada, 581 Coronation Boulevard, Cambridge, Ontaric Ni R 5V3 2Wanuftctured for Duke Energy Corporation, 13225 Hagers Ferry Road, Huntersville, NC, 28078-8985

3. Location of Installation Oconee Nuclear Power Plant Unit 2, South Carolina 4. Type; 068SE001 See List #1 See List #1 -2003 (draweig no.) (Mail spec. ra) (tensite Stranp) (CRN) (year built)5. ASME Code, Section HL Division 1: 1989 No Addenda I (See Note #1)(eddon) (addenda date) (dass) (Code Case 0o.)List #1: Material Specification 1 Tensile Strength (Min.)Closure Head SA-508 Cl. 3 80 ksi Lifting Lugs SA-508 Cl. 3 80 ksi CRDM Flange SA-182 Gr. F316LN 70 ksi CRDM Tube SB-1 67 UNS N06690 69.9 ksi List #2: Nominal Thickness Minimum Design Thickness ,losure Head 7.00 -4.41" Lfting Lugs 5.625" 5.50" CRDM Flange 2 75" 2.48" CREM Tube 0.625" 0.204" Note #1: 'Per NR 26755, temper bead repairs were done on selected CROM to head welds. The repaired welds were -examined in accordance with the rules of NB-4622.11 (d) (3) per the ASME Code, Section lII, Division 1,1992 Edition with1994 Addenda. This Is the only Instance for this component that the ASME Code, Section Il, Division 1, 1989 No Addenda does not apply.11 .i.1. :7 5.I W.11'T I-5, .71 i 17k.- G:Or.DW6ASV20'63SQ.1doC R gic-IBx-crg:ti. ,,i,-,ito

`a`-9.S CIATA IRIPGiG. -R 1:rl 0:5TIGC'-s

N"Y'CL-A; PART.S AND APU-sRb';-S As n zsaurssd b-- the "Provisi.-ns olsat ASe .rS Code, o¢ni'll NoT to xoe;One Day's P-oduealn 1. wauawe ;-nc cst--e by Z Mnuftvu red fcr' ftirc z --. 31C;-.on avd.-, Cr-xw.< IR-,=i-M LW -x .b3-. 3r rid ets ot a a NERr Y ............................................

^sr ......3. Locationcfinsf:alsttiavOn Cr Eee Nub-eaz Pow-r TamF, Itnit 2. 4CJ oiee^ so5&U _-tZQ 1" 4. Type. ;111849V' f Rev. c5 SA-_08, C_.; 3l^8~2 -.......-- 5.ASME Code,' Sewian 11I, Oivision t: ?Taq _ g ¢deindi --: 6. Fabiricea,;d in ACCOrdance wi*h Ctrs5 Spe_.. M~iv. 2 only) -_- 'Revision- ---:- _D2 --_Hydzis -*; ocstaU6vsti ncot t~od4 eJm:Sc .:-.r..Claddiu4: thidcimes-:. 'sIi~t..0 xi reie~........................................... ps ..... -0.20 .r .b. ..-,; .... ~, .!Clddrtq -'aietsrl~s-are SIA-1A., ARE CL_ EX9-1:.05Lh -:--.- -. .;* NoYm' tickriss'(1n.) 7- N :Wn. dtsign'thickknesstn~ (h) 4) DI'i ji2il I'ra 7liglce"(iq6 -73a14^9. When applicable. Cerfifte Holdirs" Data Rpyaea~~i oec t Reoftis re ataid C* each.................................. i ;.-...,.t .m:-. o fti~--*:7..,.: '1. .-Si ' '{ ..A..; ; ;;:.- 9!P;.:..., ' "-,:.;A::.,'I i:.:-, , ,, A.,% , .* St he e t' * ':.- , .An'**.zt*.:1., ....., .: ;,:.:..*: ,, .., -; .A);, f ;' ..iS: v t , ,'. -Nashonat .Part or Apourterrance Board No.-..Serial.NUmnber In Numeriafs Order.(11 1064 -.6.14j ' ': ..-,: : -: : -.{S 0) --; ..: t a 2, --:. .'*w,_, 141A ,': ' by)" ' '-' " ' ' " " ', ' ~~~~~. *-,',. '_ ,..'r*{° .1,'7 ..; ,'_a......... ,.....is- ,, 21.....li)(22 -.; :.ft2) l.'.MAIb ) ,s.,, ,a Selrimbir-,National-.....- --i Numerkcaiter -t i126L-i ." i .. .-213*. -t Gu77

  • t..~~~~~~yn t (28 -..:-i. -:---;;.9'-.;5

(:i9 ;*,.r.43!4.. ...........

2.-.... -_w........2.,..4.,--

1{31t * ;-; < ' ' ! ; > :*; "7- ,::(4} 9t:: :. i:. ; .. .........:., 1... .- .I ' -. -1 I , -.I,,.--:I,.

10. Desin-resue m" psi. -1Eirmp; f/P F Hydraz. ;est cressuirs

--a tern t iFnuded arr eacn sheet, l37 22rn& slide' is nxisnieeed 2airi 141s ntumber of she ets is. r-c,-rded at the toap

  • this fhrn.- --'-.*P.O. It2.: 0133a-714a Job }^ a. >,tw ..'l-30 ;Beat No. : GW1RS-1-1 JSWt PC. b : .3 FOR \-Z :Sac'k -? 2 C -i;cB:--F-PCA-S.CN O-F CE~iGN-7s5I :~Jzeccs2

!C-s to!e 0 ir it-w :--=~-tca -e .-LN -a- .;. Vi~ -~jj ~theadein 'ils Ceccra f-czrmtcland thiet '1*is (ihee crcrxims to the riles of co~o. of e ASMECcdS S:on 1II, Oivision,'.. !PJT Certificate cof Authorization N. *E ip-72-E. -3e 2;9' 20.04 be -:;m5el WcrkcsjiLtd- ..Oa~t- Mar. 14, C~ NaS~Urf ~ zi.. ..c ____ ____I cERTIFICAT FIS~T I. the undersigned. holding: a valid corrrnissiora issued:by th e Nationalt Board gol Bor and Pressure Vassel Inspflctre and~-the~ Stat o-Pouc f of______and emp'loyed Sy k S 1% & ~t- CO ________of F T.haPmsecD these 1ars describ= dIn th.s- Dat er o ~-a ds.e n o.h!fl. Division 1; Each ~pzrit listed. has~ be'en s~thadizsdfori~tapfing on:.6te date -,shown above.By signing This ce-tificate, neither the insowectC norhnis emp'oy'er rti~keS any..irrV exprss.eld ar-pi~~cn 1'imndn eu~e~dsrb~i tis ~taRepot Frthrmoe, eth'eT th~ insector nor nit rnop~b~ec shsll b= Wable in any mannerfror any perscnal ilr rpl dma qt or os oran knd riin frm rcnnicted. wih thdiis inspecraon.s'" Cofri7d ~ IBUL~ .~niA~.I_________________ VCLC' -. ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ Ci riisi ns c d t~.e~~~f~il i ~i rec.icc.r'I A: } -*::: ;b --v-ealulla:uS

  • . .-, .: .I .: ~.. Mut~rze dear *,rpero., :: : * '.' ...*.8{d;( e a t d. tf e. v.vi,.waw ; ~ 4 ~ C ~;- 1 i--ACOMWC "NSPECTIDtN.-

IAPPROVED: r FORM NIS-2 OWNER'S REPOSE OR REPAIRS OR REPLACEMENTS As Required By The Prov. is Of The ASME Code Section Xl 0-1. Owner -Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 1.a Date 9/30/04 Sheet 1 -of 3 2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 2a. Unit r 1 172 r3 r Shared (specify Units 3a. Work Order# 98617114 Repair Organization Job #3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp NIA Authorization No. N/A Expiration Date N/A 3b. NSM or MM # ON-23112 Part AM2 WP23535H 4. Identification of System Reactor Coolant System Class 1 5. (a) Applicable Construction Code ASME 1989 Edition N/A Addenda, NoAddenda /Code Cases NIA (b) Applicable Edition of Section Xl Utilized for Repairs or Replacements 1989, No Addenda (1992 through 1992 Addenda for Class MC and cc and their supports.) Ir4onfifinafinnr nf (~nmnnngantQ Pannairme nr RanInnard anti Paninnamant trnmnnn~ntAq A Column 1 Column 2 Column 3 Column 4 Column 5 Col. 6 Column 7 Column 8 I National -ASME ode.Manufacturer Board Other Year Repalred, Replaced. Stamped (vyes a Name of Co n ame of M. a nuiaoturef Se.ra' Number Number Identification Built or Replacement or no)_SEE ATTACHED SPREA CHEET r Repalred F No SPREADSHEET SPREADSHEET FrReplaced Ye FOR SERIAL FOR CORE r Yes A Segment Flange Framatome ANP NUMBERS NIR LOCATIONS 2003 P. Replacement SEE ATTACHED SEE ATTACHED r Repaired i; No SPREADSHEET SPREADSHEET r Replaced FOR SERIAL FOR CORE r Replaced r Yes B Hold Down Bolts Framatome ANP NUMBERS NIR LOCATIONS 2003 F Replacement F Repaired r No.r Replaced r Yes c r Replacement C.r RepaIred r No r Replaced r Yes D r Replacement r RepaIred r No r Replaced r Yes E .Replacement r Repaired F No r Replaced F Yes F r Replacement Form 1IIS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size Page 2 of 3 is 8 1/2 in. x 11 in. (2) Information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.7. Description of Work New segment flange and 8 hold down bolts Installed on each core location.8. Test Conducted: F Hydrostatic r Pneumatic 17 Nominal Operating Pressure F Other F Exempt Pressure psig Test Temp OF Pressure psig Test Temp OF Pressure psig Test Temp OF 9. Remarks Installed old CRDMs with new segment flange (split nut ring) and 8 -1 1/8" hold down bolts on the CRDM Core Locations listed. Old segment flanges were left on old head and old hold down bolts were discarded as radioactive waste. Attached spreadsheet lists core location for each of the new segment flanges and bolts used to Install the CRDMs.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the iules of the ASME Code, Section Xl.Type Code Symbol Stamp N/A Certificate of Authorization o 9 Expiration Date N/A Signed /< I-'4 Date A/ 361 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commision issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of OVA __ and employed by _______have inspected the components described in this Owner's Report during the period jg yO-OY to ' I.2 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. ,~~~Signatur Commissions AJ 14 fneclor's Signature National Board, State, Providence and Endorsements Date _t-3____O__ AF 2EOC20 Split Nut Ring and Hold Down Boft Location Database 1. Owner Duke Power Company IR Address -526 S. Church Street, Charlotte, NC 28201-1006 -- 11R

  • a Data (f L I l l.'I I I i--1-4 4 -. ---I I Sheet 3 of 3-+ --l-i. i l l i 2. Plant I Oconee Nuclear Station I I I I Address 7800 Rochester Rwy. Seneca, S.C. 29672 _ _ _ _ _2a. Unit _ ) _ _ __ _ __3a. Work Order# 9861 7114_3. Work Performed By Duke Power Company _ Repair Organization Job Address 526 S. Church Street, Charlotte, NC 28201-1006

_I I I_Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A _ 3b. NSM or MM # ON-23112 Part AM 4. Identification of System Reactor Coolant Svstem Class 1 5. (a) Applicable Construction Code S§M E.. 1989 Edition LAddenda, Ng Addenda /C2de CaseN __=(b) Applicable Edition of Section Xi Utilized for Repairs or Replacements 1989, No Added (1 992 through 1992 Addenda for Claaa MC and ____cc and their supports.) I 8. Identiiication of Components Repaired or Replaced and Replacement Components c a t a B6 GN-49 GN-7457,7510,7295,7446,7372,7537,7489,7639 K3 GN-58 -N-7444,7241,7325,7174,7477,7276,7216,7470 B8 GN-41 GN-7296,7561,7517,7385,7460,7170,7509,7637 KS GN-59 3N-7220,7205,7518,7328,7496,7502,7344,7618 B10 GN-33 GN-7568,7416,6797,6354,7301,7224,6349,7414 K7 GN-38 3N-7369,7259,7234,7200,7181,7339,7168,7340 .--~, R i K9 GN-57 GN-7164,7249,7349,7593,7525,7233,7638,7304, CS GN-44 GN-7515,7469,7306,7453,7567,6538,7327,7643 K11 GN-66 GN-7631,7513,7332,7424,7463,7160,7615,7368 C7 GN-5 GN-7575,7417,7565,7559,7283,7270,7222,7560 K13 GN-68 GN-7319,7371 7486,7225,7274,7388,7636,7356 C9 GN-46 GN-7622,7599,7176,7236,7600,7603,7534,7543 _C 1 GN42 GN-7314,7426,7478,7475,7548,7193,6565,6581 L2 GN-28 GN6763,6814,7336,7251,7165,7383,7608,7175 -.3- u L4 GN-34 GN-7474,7440,7359,7431,7508,7522,7617,7394 D4 GN-52 GN-7256,7420,7573,7293,7596,7240,7229,7519 L6 GN-27 GN-6718,7389,7467,7626,7495,7623,7201,7255 D6 GN-17 GN-7B30,7429,7443,7507,7554,6837,7263,7326 L8 GN-63 GN-7311,7260,7594,7197,7472,7434,7454,7397 D8 GN-56 GN-7413,7273,7586,7563,7436,7238,7271,7564 L10 GN-50 GN-7213,7516,7350,7557,7387,7178,7287,7302 D10 GN-17 GN-7448,7488,7438,7491,7290,7569,7363,7562 L12 GN-51 _ GN-7391,7398,7390,7323,7570,6561,7376,7190 Ui 2 GN-9 GN-6719,6768,7545,7172,7606,7199,6749,7375 L14 GN-53 GN-7341,7307,7441,6771,6544,7571,7484,7632 E3 GN-7 GN-7353,7452,7551,7549,7524,7316,7641,7523 l M3 GN-21 GN-7267,7566,7303,7634,7348,7150,7511,7281 ES l GN-2 GN-7583,7188,6847,7185,7465,7539,7619,7364 M5 GN-13 GN-7159,7450,7179,7195,7346,6717,7620,7244 E7 GN-6 GN-7403,7428,7580,7581,7447,7433,7503,7231 M7 GN-12 GN-7498,7456,7187,7281,7597,6542,7451,7152 E9 l GN-23 GN-6574,7412,7182,7538,7601,7235,7374,7219 M9 GN-43 GN-7324,7419,7202,7227,7553,7228,7439,7279 Eli GN-35 GN-7184,6761,7459,7280,7611,7367,7278,7482 Mj Ml 1 GN-14 GN-7189,7366,7365,7505,7305,7552,7648,7192 E13 GN-45 GN-7264,7252,7345,7555,7531 7247,7358,7320 M13 GN-25 GN-7421,7400,7449,7445,7645,7337,7298,7223 F2 GGN-19 N-7334,7258,7243,7647,7183,7309,7158,7621 -N4 GN-69 GN-7308,7338,7362,7402,7530,7282,7487,7629 1 F4 GN-67 GN-7406,7277,7558,7186,7352,7535,7330,7415 l N6 GN-10 GN-7262,7208,6584,7595,7318,7226,7492,6740 F6 GN-8 GN-7455,7476,7458,7529,7242,6350,7471,7149 N8 GN-64 GN-7550,7546,7614,7248,7321,7542,7399,7628 F8 GN437 GN-7504,7396,7198,6562,6774,7607,7497,7378 l N10 GN-15 GN-7576,7430,7230,7215,7232,7269,7250,7409 F1O GN-55 GN-7254,7410,7191,7237,7462,6777,6370,7395 N12 GN-29 GN-71807373738676446578,72847425,7408 F12 GN-61 GN-7169,7642 7380,7526,7609,7646,7221,7591 TVl .,`,7 F14 GN-32 GN-7589,7157,7633,7527,7257,7315,7357,7272 5 OS l N-31 'GN-7171,7370,7461,7473,7483,6714,7480,7218 --- --m M 07 O-l O-357381,.7312,7521,7501,7547,7640,7500 G3 GN-3 GN-7624,7602,7541,7435,7574,7154,7310,7322 0 09 GN-65 GN-7203,7544,7299,6560,7217,7466,6353,6576 G5 r GN-26 GN-7212,7329,7177,7360,6815,6724,6751,7423 011 GN-22 GN-7613,7354,6753,7156,7204,7286,6813,6737 G7 GN-4 GN-7418,7404,6386,7528,7342,7163,7612,7210 l21 = & `=M G9 GN-60 GN-7392,6778,6801,7239,7211,7393,7153,7313 P6 GN-18 GN-7479,7347,7196,7300,6569,7604,7590,7536 Gil GN-30 IGN-7556,7579,7616,7355,7627,7377,7246,7161 I P8 GN-20 GN-7155,7206,7401,7610,6537,7214,6782,7335 G13 GN-54 GN-6799,7605,7331,7512,7432,7294,7167,7411 P180 GN-48 GN-6781,7268,7514,7625,7490,7533,7379,6775 --, -,. ,. --1 I 07 1 (N-1l rN-7.4qq 7!tal 7~12,7521,7501,7547,7RWfl75 H2 l GN-24 GN-7266,7343,7407,7292,7468,7361 7585,7275 I 09 GN-65 IGN-7203,7544,7299,6560,7217,7466,6353,6576 H4 GN-42 GN-7351,7422,7151,7317,6804,7494,7253,7405 011 GN-22 GN-7613,7354,6753,7156,7204,7286,6813,6737 H6 GN-39 GN-7288,7540,7427,7297,7499,7384,6741,7635 l _ , _ , H8 GN-36 GN-7587,7207,7506,7588,7582,7532,7162,7592 I I P6 I GN-18 IN-7479,7347,7196,7300,6569,7604,7590,7536 H10 T OGN-47 IN-7464,7485,7481,7194,7493,6831,7382,7584 I P8 I GN-20 IGN-7155,7206,7401,7610,6537,7214,6782,7335 H12 T OGN-16 IGN-7598,7572,7166,7577,7285,7289,7265,6742 PlO I GN-48 GN-6781,7268,7514,7625,7490,7533,7379,6775 I H14 I GN-40 IN-7442,7520,7173,7437,7578,7209,7245,7291 1 PlO GN-48 GN-6781,7268,7514,7625,7490,7533,7379,6775 -<> '-s 07 ON-Il GN-7333,7381,7312,7521,7501,7547,7640,7500 12 GN2 N-7266,7343,7407,7292,7468,7361,7585,7275 -09 GN-65 GN-7203,7544,7299,6560,7217,7466,6353,6576 I H4 GN-42 GN-7351,7422,7151,7317,6804,7494,7253,7405 Ol 011 GN-22 GN-7613,7354,6753,7156,7204,7286,6813,6737 lH6 GN-39 GN-7288,7540,7427 7297,7499,7384,6741,7635 l T -= = _ _ ' = = -L H8 I N-36 GN-7587,7207,7506,7588,7582,7532,7162,7592 I P6 GN-18 GN-7479,7347,7196,7300,6569,7604,7590,7536 I H10 I N-47 LN-7464,7485,7481,7194,7493,6831,7382,7584 P P GN-20 GN-7155,7206,7401,7610,6537,7214,6782,7335 H12 GN-16 l N-7598,7572,7166,7577,7285,7289,7265,6742 PlO GN-48 _N-6781,7268,7514,7625,7490,7533,7379,6775 I H14 l N-40 1GN-7442,7520,7173,7437,7578,7209,7245,7291 I 11 1 1 1 r 1 CLIMIRIII do Page Sec At Lni Col Rl:C THK EXI QJVR a p N m-~ CIl q m Fae ec At Lnl Col F.EC TRK EXT CVR'p ~! P -- FORM NIS-2 OWNER'S REPn- OR REPAIRS OR REPLACEMENTS -As Required By The Pro. ,ns Of The ASME Code Section XI 1. Owner Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 1.a Date ..09122/04 Sheet I of 2 2. Plant Oconee Nuclear Station Address 7800 Rochester Hwy. Seneca, S.C. 29672 2a. Unit r 1 1P2 r3 r Shared (specify Units I 3a. Work Order # 98616047 Repair Organization Job #3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 28201-1006 Type Code Symbol Stamp N/A Authorization No. N/A Expiration Date N/A 3b. NSM or MM # ON-23112 AM3 WP 23536H 4. Identification of System Reactor Coolant Class 1 5. (a) Applicable Construction Code ASME li NC 1989 Edition N/A Addenda, No Addenda /Code Class WA (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989, No Addenda (1 992 through 1992 Addenda for Class MC and cc and their supports.) Identification of Components Reoaired or Reolaced and Replacement CommonAntq 6.Column 1 Column 2 I Column 3 Column4 Column 5 Col. 6 lColumn 7 Column 8__National ---ME Code Manufacturer Board Other Year Repaired, Replaced, Stamped (yes N,, ,vua,.~a%.iu.~. ~ *,*~******,,*MM#.It c a .me amant fnlr nnl r Repaired r No Hanger/Support rReplaced r Yes A 2-57-1422-H6432 Duke Power Company N/A N/A N/A 2003 1v Replacement r Repalred 17 No Hanger/Support r Replaced r Yes B 2-57-1422-H6431 Duke Power Company N/A N/A N/A 2003 17 Replacement F Repaired r No r Replaced F Y C r Replacement r Repalred F No rReplaced F Y D r Replacement r Repaired r No F Replaced F Yes E r Replacement r- l r Repalred r No r Replaced r Yes F rReplacement Page 1 of 2 Form NIlS-2 (Back)NOTE: Supplemental sheets in form of lists, sketches, or drawings maybe used, provided (1) size is 8 1/2 in. x 11 in. (2) Information in items 1 through 43 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of --this form.7. Description of Work Replacement of RVLIS hangers 2-57-1422-H6431 and H6432.8. Test Conducted: r Hydrostatic r Pneumatic r Nominal Operating Pressure r Other Pr Exempt Sheet 2 of 2 ('i Pressure _ _ psig Pressure psig Test Temp °F Test Temp _ _ 'F Pressure psig Test Temp OF 9. Remark. Hangers 2-57-1422-H6431 and H6432 are exempt from reporting per IWA-7400 (a)(4) of ASME Section Xi due to line size < 1 " however these hangers are welded to the service structure flange which Is part of the NF boundaryvThis form covers the welds only.(Applicable Manufacturer's Data Records to be Attached)CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xi.Type Code Symbol Stamp N/A Certificate of Authorization No. NIA S Expiration Date N/A Signed Zio E 0 oS 4'zE Date 0'TZ a CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commision issued by the National Board of Boiler and Presu; Vessel Inspectors and the State or Providence of --and employed by _____have inspected the components described In this Owner's Report during the period .-iz22 to Go- L; and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions k ? t)jR Pi_ _ __. _ _I n/pecto~e S Idinattre Date .iL-41-4L National Board, State, Providence and Endorsements Page 2 of 2 f f--IA'M frflt.m- .p a.V

  • Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I Work Order Number 98745816 Sheet I of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/15/2005
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201 -1006 Expiration Date Not Applicable
4. Identification of System, ASME Class High Pressure Injection, ASME Class 2 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)Pipe (1) DPC None None None 2005 Installed NO 436J-DE-012 (2) DPC None None None 2005 Corrected NO 436-DE01 _2 I 9 4.- I 4* 4.- *I.4_ ._- -..4 .4 4 4. 4-.. 4______ _ =_ ___ ___7. Description of Work The piping inlet flange was pitted and was replaced prior to the flange develop a leak. To aid in the replacement a short i k ection of pipe was also replaced and the u-bolts that hold to pipe to a hanger were replaced.8. Test Conducted El Hydrostatic I Pneumatic Pressure J Nominal Operating Pressure D Exempt R Other PSI Test Temperature OF I Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI _Work Order Number 98745816 I Sheet 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)o The following items were replaced either for ease of maintenance or preve$&i Nr , 2 inch stainless steel pipe, SA 312 F304, stock code 149537, UTC # 10;8759 2iiqjf N pipe flange, SA 182 r3 stock code 87821, UTC #1084048; 2 inch stainless steel full coupling, SA 1821304,YNsock code 67999, UTC # 1081617; 5/8 inch threaded rod, SA 193 B7, stock code 297412, UTC # 1083362; and 2 inch heavy hex nuts, SA 194 Gr. 2H, stock code 293556, UTC # 1074343.e The following parts were replaced on pipe support 2-51B-436J-DE-012:

3/8 inch bent bolt with nuts; Stock Code 35313, UTC #1074993 (U-bolt 3/8" dia. x 2" NPS)e 0 e 0 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Nc't Applicable Signed jg X4i- L a Senior Engineer Date 11/15/2005 6wner or ner'soesigWe, Title U I CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,.aoerdv ck~, w and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period /0- ;'- Or to ..' ./2-o a , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions National Board, State, Province, and Endorsements -Inspector's Signature'Of Date v Z -JZ -r Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number 98503437 Sheet 1 of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 j 11/16/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class High Pressure Injection , ASME Class 2 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section XI Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)Wp-stream Orifice UNK UNK UNK UNK UNK Removed NO A ssem bly__ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ __ _ _ _ _ __ _ _ _Up-stream Orifice FlowServe UNK UNK PN: CPM-9428-UNK Installed NO Assembly (1) ______ E479-7 ____Down-stream UNK UNKUNK UNKUNK Removed NO Orifice Assembly Down Stream PN: CPM-9429-Orifice Assembly FlowServe UNK UNK E479-7 UNK Installed NO (2) E7-Pipe (3) DPC None None None 2005 Installed NO 435H-JC- 1802(4) DPC None None None 2005 Corrected NO 43HJC10 _ ., _4_ __ ==_7. Description of Work The orifice assemblies are made with a series of stacked plates. Each refueling outage the orifices assemblies are RT to ensure the inside parts have not started to wear out. When wear is detected plans are made to repla.e at the next available outage. During last RFO wear was noticed so it was decided to replace orifice assemblies.

Both orifices and a section of pipe was removed to allow replacement.

8. Test Conducted H Hydrostatic F Pneumatic 3 Nominal Operating Pressure a Exempt l Other IF Pressure _ PSI Test Temperature

_ OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 98503437 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)o Up-stream socket weld orifice assembly from Flowserve; CPM-9428-E479-7; stock code 439460, UTC t 1062050; SA 479 TP316L 0 Down-stream socket weld orifice assembly from Flowserve; CPM-9429-E479-7, stock code 439461, UTC # 1055596 e 1.5 inch SS pipe, SA 376 TP304; stock code 149472, UTC # 1077294; Section III Subsection NC.0 Stainless steel pipe attachments replaced as part of the pipe: change out. Stainless steel flat bar, 1/4 inch thick x 2 inch wide, A 240 Grade 304, stock code 21700, UTC # 1042632 e.-0 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Net Applicable Signed Senior Engineer Date 11/16/2005 Owner or Owner's Deysjnee t CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,hi~ez.Ja and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period _ -_____ or to 3/-So or , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. f__ ___ ___ ___ ___ __ _ fCommissions 4/& $Y '// AdL rsspector's Signature National Board, State, Province, and Endorsements n//t //-so <rl LJUsL Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI.~~ .I Work Order Number'98738640-02 Sheet 1 of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/8/2005 3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable

4. Identification of System, ASME Class Steam Generator

-Reactor Coolant System, Feedwater System, ASME Class I 5. ( 142 (a) Applicable Construction Code: ASME Section III 19 Edition, No Addenda, _I42 Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)2A Steam Generator, B&W Canada 006K03 207 2003 Removed YES Primary Tubing ._ _-_= = --=7. Description of Work-or ---- _ _ _ _Frubes (row-column) 53-114 & 86-118 are being removed for metallurgical examination of wear scars and will plug tubesheet by welded plug in lower head. These are not defective tubes that would require repair and are being pulled to assist with root cause evaluation PIP 05-2678.8. Test Conducted F1 Hydrostatic F] Pneumatic [i Nominal Operating Pressure B Exempt Pressure PSI Test Temperature L1 Other Form NIS-2 Owner's Report for Repair/R eplacement Activity As required by the provisions of the ASME Code Section XI WorkOrderNumber Sheet 98738640-02 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)O Alloy 690 welded plug. (Framatome P/N 5052976-001, Stock Code 590067) ASME designation N06690 ASME SB-166 s(/- 3q{31/e Alloy 690 welded plug. (Framatome P/N 5052976-001, Stock Code 590067) ASME designation N06690 ASME SB-166 0 0 0 e 0 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed / i I Date // -/- 2--// Owner or Owner's 'signeD TitleU CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of , o and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period / 0 -o4- Or to , *.t-o s- , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions AWl l1 ector's Date Signature National Board, State, Province, and Endorsements Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI-Work Order Number 98758028 Sheet 1 of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/14/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Low Pressure Service Water, ASME Class 2 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)~1itFanged LPSW__headers for 2B2 DPC none none none 1970 Corrected NO RCP Motor Air C oo ler (1) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _4 4. 4.- I 4..9 1 1 .9 .9 4 .9 -4. 4. .9 4. 4 I- 4 4. 4- 4 I. h & I d. *7. Description of Work The flanges on the LPSW hearer were one hole and the flanges on the upper air cooler were two hole so one set of flanges had to be rotated so the flanges could be bolted together.

Since it would be easier to pressure test the header pipe'nd welds it was decided to rotate the header flanges.8. Test Conducted X Hydrostatic LF Pneumatic FI Nominal Operating Pressure LF Exempt LI Other Pressure 115 PSI Test Temperature 68.5 OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number 98758028 I Sheet 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)o Replaced two 3 inch carbon steel flanges with stainless steel flanges. Material SA 182 Grade F304, Stock Code 87823, UTC #s 842434 & 1007241.e§CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed 4a--A l Xt Id Senior Engineer Date 1 1/14/2005 Owner or Ownerwfesi !4, Title CERTIFICATE OF IINSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of o geviv and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ,/_. Y ' -to .z-ee-o S , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section .l.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. i i`~-tor's'Date /,-o3 lI Commissions at Signature National Board, State, Province, and Endorsements Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI-_Work Order Number 98554046-03 Sheet 1 of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/10/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class High Pressure Injection, ASME Class 2 5.(a) Applicable Construction Code: USAS B331.7 19 69 Edition, No Addenda. No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)for Valve 2HP-7 1 UNK UNK UNK UNK UNK Removed NO Inlet Pipe Flange for Valve 2HP-71 lJNK UNK UNK LJNK 2005 Installed NO (1)7. Description of Work Flange was replaced because the original flange had developed pits overs its 30 year life.0 0 8. Test Conducted[l Hydrostatic i Pneumatic Z Nominal Operating Pressure L Exempt Other H Pressure PSI Test Temperature OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number 98554046-03 I Sheet 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)0 3inch stainless steel WNRF flange: SA 182 Grade F304. UTC # 917811. S/C # 87809 e e 0 e 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp Not Applicable Certificate of Auth ization Number Not Applicable Expiration Date Not Applicable Signed Sertior Engineer Date 11/10/2005 Owner or O0e?/Designee, Title 3 CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of hagse V and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period S-, 6° $ to or -o s , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions /4 ' ./A'c 1%IInspector's Date °Signature National Board, State, Province, and Endorsements I Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number 98754948 Sheet 1 of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/15/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not App[icable Charlotte, NC 28201-1006 Expiration Date Not Appllicable
4. Identification of System, ASME Class Feedwater System, ASME Class 2 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xi Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / Na)Pipe (1) DPC None None 'None 2005 Installed NO 7. Description of Work The original pipe assembly was removed due to a leak. The assembly was sent to the Applied Science Center for cause valuation.

The cause for the leak was determined to be due to poor quality weld. There was lack of fusion in the root Grass and porosity through out the weld.8. Test Conductedl Hydrostatic n Pneumatic 3 Nominal Operating Pressure E Exempt l Other Pressure PSI Test Temperature ___ IF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet I 98754948 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)o The following parts were replaced by this work: 1 inch Pipe Cap, 3000 #, SA 105, stock code 48299, UTC # 1049171, Section III Subsection NC material; I inch Half Coupling, 3000#, SA 105, stock code 68455, UTC # 1066185, Section III Subsection NC material; and 1 inch Pipe, Sch. 80, SA 106, stock code 149370, UTC # 1062927, Section III Subsection NC material.0 0 0 e Aw 0 0 0 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Ap licable Expiration Date Not Applicable Signed / -O Senior Engineer Date 11/15/2005 Owner or er's e e, Title CERTIFICATE OF IINSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of G d,*tw and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period O to W/-Zf.o -, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any wind arising from or connected with this inspection. Commissions __ _ _ __ _ _ __ _ _ __ _ _Inspector's Signature National Board, State, Province, and Endorsements Date 7-2t f Ih -- Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI -.Work Order Number 98727683-38 Sheet I of 2 1. Owner 2. Plant Unit 2 Duke Power Company Oconee Nuclear Station 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 2820 1-1006 Seneca, SC 29672 11/16/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Coolant, ASME Class 1 5.-(a) Applicable Construction Code: USAS B331.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number B3oard No. Identification Built Removed, Code or Installed Stamped (Yes I No)Rear pivot mount Grinnell N/A N/A N/A N/A Removed N/A for Fig. 200 Rear Brkt for Fig. Grinnell N/A N/A N/A N/A Removed N/A 200 Fig. 201 Extension Piece Anvil N/A N/A UTC 1085258 N/A Installed N/A Rear Brkt for Fig. w; N/A N/A UTC 1081978 N/A Installed N/A keF' 144O t 4j lIA l/ NIA tN/A Pkevomte UI14 Reau f,3r~) 4.'I"ZoN/A N/A LAM~ 106 913q N14 jd~ifkl" N/A 7. Description of Work Revised RCPM snubber support 2-50-0-1066A-RCPM-2B2-SS1 per OE200419 8. Test Conducted E Hydrostatic nI Pneumatic L Nominal Operating Pressure LI Exempt E Other Visual Pressure PSI Test Temperature OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I Work Order Number Sheet 98727683-38 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)0 0 0 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed i4 e < . k --- Date /1// __/__ _Owner or Ovwner's Designe, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of X,&trA Z'teoe>.1NA and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period Yo -2 7-DoT- to //2/-ofu , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__ Commissions _ _iC_ _ __) _ _c _lnspector's Signature National Board, State, Province, and Endorsements Date 4 '.- E- - Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI..._ ., Work Order Number 98727683-40 Sheet I of 2 1. Owner 2. Plant Unit 2 Duke Power Company Oconee Nuclear Station 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/16/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Coolant, ASME Class 1 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)Misc. Plates N/A N/A N/A N/A N/A Removed N/A Rear Brkt for Fig. Anvil N/A N/A UTC 1068739 N/A Installed N/A 200 1 " plate (item N/A N/A N/A UTC 1072774 N/A Installed N/A# 18) _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _#1712 paeie N/A N/A N/A UTC 1071258 N/A Installed N/A#17) __ _ _ _ _ _ _ _ __ _ _ _7. Description of Work Revised RCPM snubber support 2-50-0-1066A-RCPM-2B2-SS3 per OE200419 8. Test Conducted[i Hydrostatic

[] Pneumatic R Nominal Operating Pressure FI Exempt J Other Visual Pressure PSI Test Temperature OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section Xl CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed / f ' Z /4 I Date /_/_//_ _ _ _ __ _ _Owner or Orwner's DesignieTitle CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of A41,rA' 4!.t'oeI..sN and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period /0 o pt A , to M/-2/- or- , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions A/C/A~o/Aft Inspector's Signature Date //-& / -oR National Board, State, Province, and Endorsements Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number 98727683-39 Sheet I of 2 1. Owner 2. Plant Unit 2 Duke Power Company Oconee Nuclear Station 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/16/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Coolant, ASME Class 1 5.(a) Applicable Construction Code: USAS B331.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number B3oard No. Identification Built Removed, Code or Installed Stamped (Yes i No)Plates & pipe N/A N/A N/A N/A N/A Removed N/A Rear Brkt for Fig. Grinnell N/A N/A N/A N/A Removed N/A 200 Rear Brkt for Fig. Anvil N/A N/A UTC 1068739 N/A Installed N/A 200 2" plate machined N/A N/A N/A UTC 103 6576 N/A Installed N/A to 1 1/2" 7. Description of Work Revised RCPM snubber support 2-50-0-1066A-RCPM-2B2-SS2 per OE200419 8. Test Conducted Hydrostatic Ej Pneumatic FI Nominal Operating Pressure LI Exempt 1i Other Visual Pressure PSI Test Temperature OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 98727683-39 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)0 0 0 CERTIFICAT E OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Noat Applicable Signed AF go A Date J/Ca OwL4 ner or Owner'I D-esignee, Tfe CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of A1/oX7,, Gf4. eOd& v1 and employed by HSB CT Of Hartford, Connecticut have inspected the components described in this Owner's Report during the period /c? / ' OS- to .//-Z/-O5 , and state that to the best of my knowledge and belief, the Owner has performed examinations and takien corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

HiCommissions AJ/1C1VLV-J-1Vdc


nspector's Signature National Board, State, Province, and Endorsements Date Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI.Work Order Number 98711484 Shet -1 of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/16/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Appl icable 4. Identification of System, ASME Class Reactor Coolant, ASME Class 1 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)2RC IV 163 Kerotest .Go1 K = Removed NO 2RCIV-163 Flowserve 49BAH 1412 UTC-1075671 2004 Installed YES 4 4 4- 4. 4. 4- +.4 J. .4 -4 .1. .1.7. Description of Work I OE200154 Replaced Valve and tubing fitting.-8. Test ConductedlI ydrostatic Pneumatic FLI Nominal Operating Pressure L Exempt OtherF H Pressure PSI Test Temperature OeF r Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I Work Order Number 98711484 I Sheet 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)0 Replaced leak injected valve.0 e 0 e 0 0 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed U -1 TE%\CA*'..

5?sckkL.1r Date 11 \ S Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of A.6 .' G .,A and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ________ to A-' f- , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XL.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. inspector's Signature Date Xi'i44 -Commissions =,'< 4'c National Board, State, Province, and Endorsements Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI..._ ..Work Order Number 98759439 Sheet I of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/15/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Low Pressure Service Water, ASME Class 2 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)Pipe (I) DPC None None None 2005 Installed NO 7. Description of Work I During installation of the Low Pressure Service Water header it was determined that one flange on the air cooler was not narallel so the flanges did not mate together.

To correct this problem the flange on the header was cut out and adjusted I O'by adding a section of pipe.8. Test Conducted 0 Hydrostatic F] Pneumatic n Nominal Operating Pressure D Exempt F__Other Pressure 115 PSI Test Temperature 69 OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number_ 98759439 I Sheet 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)0 The followin2 part was replaced: 3 inch carbon steel schedule 40 pipe, SA 106 Grade B, stock code 1493 34, UTC # 1074681 0; _ __0 O COMPLIANCE 0 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed /4 1 , 1 1 1 Senior Engineer Date 11/16/2005 Owner or wner sfe inee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of V &v4,. and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period // -/a- CD to //-.I _OS , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions 4C/m A't-i,*I-Tnspector's Signature Date // 05 National Board, State, Province, and Endorsements 0 Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI-U _.Work Order Number 98727280 Sheet 1 of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -0 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 6/6/2005 3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable

4. Identification of System, ASME Class Condenser Circulating Water, ASME Class 3 5.(a) Applicable Construction Code: ASME Section III 19 77 Edition, 1978 Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)i Standby Shutdown Facility (SSF) HVAC Ingersol-Rand 0979-173 UNK Model 1 x 10 1979 Corrected NO Service Water Pump # 1 I-~_ = _== --7. Description of Work Work on this pump was performed to repair a packing leak. During this work technicians noted the bolting associated with the packing galnd was corroded.

The bolting was replaced as a good maintenance practice and the pump was repacked.l 8. Test Conducted Ad [1 Hydrostatic LI Pneumatic 3 Nominal Operating Pressure LI Exempt Pressure PSI Test Temperature L1 Other Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI _Work Order Number 98727280 Sheet 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)o Bolting for the packing pland on the SSF HVAC Service Water Pump # 1 was replaced. This included 2 packing gland studs (ASME SA 193 GR B7, Stock Code 205134, UTC 967055),21 packing glud nuts (ASME SA194 GR 2H, stock code 293556, UTC 1074343), 2 Gland Follower Bolts (ASME SA193 GR B7, Stock Code 176981, UTC 1011645), 2 Gland Follower Nuts (ASTM A194 GR 2H. Stock Code 131419. UTC 1073090)0 e 0 0 e 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xi.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Nat Applicable Signed e) ))A.. Ago-L Date L_ __;L_3 /D0S5 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of A,/0,erw L 1'zaz ,A)4 and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 4 -C -oSr to .o-Zo -o"S , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any ,kind arising from or connected with this inspection.<j U Commissions A/I-/i/ AId"C--tispcror's Signature Date Jo -Zo -OS National Board, State, Province, and Endorsements Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number 98705438 Sheet 1 of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/02/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Liquid Waste Disposal System, ASME Class 2 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)2LWD-99 Velan UNK UNK None UNK Removed NO 2LWD-103 Velan UNK UNK None UNK Removed NO 2LWD-99 Flowserve 67BAQ 1459 UTC-1078379 2005 Installed YES ILWD-103 Flowserve 65BAQ 1457 UTC-1078377 2005 Installed YES OPiping DPCo None None None Unk Corrected NO Piping DPCo None None None 2005 Installed YES 7. Description of Work NSM-ON-23106, Piping and valves downstream of Penetration 40 was replaced to upgrade from Class 3 to Class 2. In ,addition.

a tee was added to allow tving into new BPI Pining. -.Test Conducted E] Hydrostatic D Pneumatic El Nominal Operating Pressure El Exempt 1Z3 Other *Performance test Pressure 60 PSI Test Temperature N.O.T. OF 41J. a*C I:.Fohn NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI _-j Work Order Number Sheet_2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached) ._ Ad- .,.o Portion of LWD piping was xernoved with valves to upgrade pipiug to Class 2.O New LWDJHPI piping to CVs 2LWD-103 (2LWD-99 opn) Sand 21IP-973/974 tested at containment designpress C i, e..... ,,.CERTIFICATE CF CSOMPLACE vfI certify that the statements made k- the report are correct arnd that thiss conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed 4AA4 , S AA;Leezd Date 11 o5 Owner or Owner's Designee, Title CERTIFICATE OF INISERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Afoer// Zxee.e, .' and employed by HUIB C'of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 5-7 7- to .I/-.Z/ o 5 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warrarny, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Purthermore, neither the Inspector nor his employer shall be liable in any manner lbr any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions Al/ e-Inspector's Signature National Doard, Stat; Province, and Endorseineats Date _ _ _ -Z,_ _ _ _1.d 1 vd ; *I Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI= ..._ .Work Order Number 98705438 Sheet 1 of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/2/2005 3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable

4. Identification of System, ASME Class High Pressure Injection, ASME Class 2 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed (StasmpNeod (Ye _ o HPI piping DPCo None None None Unk Corrected NO£ I J. 4 I 4- +7. Description of Work NSM-23106

-Portion of piping connected to LDST was re-rated from 100 psig to 150 psig. The system operating pressure was not changed and no components were replaced. Existing components were evaluated for acceptability.

18. Test Conducted D Hydrostatic Pneumatic Nominal Operating Pressure 3 Exempt ElOther H Pressure PSI Test Temperature OF rI Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI i Wrk Sheet 2 of 2 9. Remarks (Applicable Manufacturcr's Data Reports to be attached)

I -0 A.M Coe Seto.I T ..'Cr.. .__ _ .;e-CERTI1FICATE OF SEVCO IANSPCEIO I etfyta the unesigtedhednts ad vaid themireiont arsed boycta theatthis conarms tof thler anrequsurmesesfsth Asce Codeo Section XI.Cer signicat g Athorizartionce numbher the Apsplicablo semployermksatiny D arate noty exppicaedripid concrnin theexOwnations awndrcorrecineTtivemesrsdsrbdithsOn'sRpt.Ftemoenihrte Inspectors nor the Stateoyr shrove inc leo inan mannr foan proal ndjeryoyr brpry damag oralssoTn kind ahisiOne ros Reor et duingth perios inspection.e-~ a sat ta Inspector'nrsimpoe ShgallteuialeNianymnnrtoinypronal nuyor4 SttiProperty , danag 1oralss of any oate..'. Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI-U Work Order Number 98705438 Sheet I of 3 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/2/2005 3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable

4. Identification of System, ASME Class High Pressure Injection, ASME Class 2 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section XI Code Case(s) None 6. identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes 9 No)2HP-939 Velan N 052011 None UTC-1078944 2005 Installed YES 2HP-940 Velan 052012 None UTC-1080398 2005 Installed YES 2HP-969 Flowserve 59BAQ 1451 UTC-1077003 2005 Installed YES 2HP-970 Flowserve 6 61BAQ 1453 UTC-1078373 2005 Installed YES 2HP-973 Flowserve 9 41BAG 1467 UTC-1076040 2005 Installed YES 2HP-974 Flowserve 44BAG 1406 UTC-1074811 2004 Installed YES 2HP-981 Flowserve 70BAQ 1462 UTTC-1078382 2005 Installed YES 2BP-982 Flowserve 64BAQ 1456 UTC-1078376 2005 Installed YES Piping Material DPCo None None None 2005 Installed NO 7. Description of Work NSM-23106 AM1 and work order 98705438 installed two MOVs , 4 manual valves, and two check valves with associated piping and fittings on the HPI system. Installed twelve (12) new supports for new piping and components.

0 Test boundary f%. Test Conducted F[ Hydrostatic ] Pneumatic 3 Nominal Operating Pressure FlExempt 0Other Pressure 66 min PSI Test Temperature N.O.T. OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number 98705438 Sheet 2 of 3 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/2/2005 3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable

4. Identification of System, ASME Class High Pressure System, ASME Class 2 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)2-51B-1435B-DPCo None None None 2005 Installed NO H5560 Support 2-5 lB-1435B-DPCo None None None 2005 Installed NO H5561 Support D~2-51B-1435B-DPCo None None None 2005 Installed NO H5562 Support DPCo None None None 2005 Installed NO H5561 Support DPCo None None None 2005 Installed NO 2-51B-1435B-DPCo None None None 2005 Installed NO 115564 Support D~2-51B-1435B-DPCo None None None 2005 Installed NO H5565 Support 2-51B-1435B-DPCo None None None 2005 Installed NO H5566 Support I__ _ _ _ __ _ _ _ _ _2-51B-1435B-DPoNone None None 2005 Installed NO H5567 Support D~2-51B-1435B-DPCo None None None 2005 Installed NO H15568 Support D~2-51B-1435B DPCo None None None 2005 Installed NO H5569 Support I'-51B-1435B-Ii*A5570 Support DPCo None None None 2005 Installed NO I 2-51B-1435B-DPCo None None None 2005 Installed NO 115571 Support I _ __I___I_ I I -I Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI _I Work Order Number 98705438 I Sheet 1 3 of 3 9. Remarks (Applicable Manufacturer's Data Reports to be attached)0 The pressure testing covered by this NIS-2 covers new HP [ piping up to 2HP-98 1 and 2HP-982. The balance of the new HPI piping is part of the containment boundary and was testing with the LWD piping. NIS-2 included with this WO package.0 e 0 e 0 0 0 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed Ja , .4 At- I-e's' ef1eep Date 1/ oS Owner or Owner's Designee, Title CERTIFICATE OF IINSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of koerlew L'eocL.A and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period J'/7- as to ,/Z/-'.'S ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

`-Inspor's Signature Date //_ Z__Z_-__ _ _'Commissions 416 / S<' /- c National Board, State, Province, and Endorsements Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number_ 98705438 Sheet 1 of 2 1. Owner 2. Plani Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 10/12/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Low Pressure Injection, ASME Class 2 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section XI Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)2LP-193 Flowserve 68BAQ 1460 UTC1078380 2005 Installed YES 2LP-194 Flowserve 59BAK 1438 UTC1074854 2004 Installed YES Piping DPCo None None None 2005 Installed NO Support 2-51B- DPCo None None None 2005 Installed NO 1435B-H5572 Support 2-51 B- DPCo None None None 2005 Installed NO 1435B-H5573 Supr -SIB- DPCo None None None 2005 Installed NO 1435B-H5574 Support 2-51B- DPCo None None None 2005 Installed NO 143513-15575 Support 2-5B1- DPCo None None None 2005 Installed NO 1435B-H5576
7. Description of Work NSM-23106AM1 and work order 98705438 installed two new manual valves in the LPI system. Associated piping and fittings were also installed.

Installed five (5) new support restraints on new piping.L -------- -I. Test Conducted' Hydrostatic a Pneumatic " Nominal Operating Pressure E Exempt LI Other Pressure 83.4 PSI Test Temperature N.O.T OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of ihe ASME Code Seation XI_ , Work OrNumer Sheet I % = 2 of 2 9. Remarks (Applicable Maufautsrr's astas Reports to be attaced)0 I- -CERTIFICATE OF COMPLIANCE fI certfy that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xi.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed Aog AA QGtu= Date ,l -Z / -Owner or Owner's Designeci Title I i i i_ ... ...CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of e e and employed by rnSI CT of Hartford> Connecticut have inspected the components described in this Owner's Report during the period _ -_ _ _ _7-___ r to /- Z/ 0-oS' and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xi.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied.concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Isco rtrCommissions tC VJ/xse National Board, State, Province, and Endorsements Date LIZ Form NIS-2 Owner's Report for Repair/Rteplacement Activity As required by the provisions of the ASME Code Section XI-.Work Order Number 98693392-01 I Sheet I of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/16/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiratlon Date Not Applicable
4. Identification of System, ASME Class High Pressure Injection, ASME Class 2 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)Snubber 2-51 -Lisega 61296/038 N/A N/A N/A Removed N/A 1478A-H6147 1478A-H6147 Lisega 61587/012 N/A UTC 1064697 UNK Installed N/A 1- 4 .- 44 4_4 4 I 4-- 4. 4 4 4 7. Description of Work Replaced Lisega snubber containing AK350 fluid with one containing AP280.8. Test Conducted 2 Hydrostatic 2 Pneumatic R Nominal Operating Pressure j Exempt Z Other Visual Pressure _ PSI Test Temperature

_ _ OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 98693392-01 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)0 0 0 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xi.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed 4 AG O 3, *, Z,62: Date 1,/ / /as Owner or Ownef's Designee, lM1e CERTIFICATE 01 INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of 4,10,ecr, zoeLw, and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period b/ Z, -oa to /W'Z/.o r , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any is kind arising from or connected with this inspection. Commissions _ _ __ _ __ __ _Inspectors Signature National Board, State, Province, and Endorsements Date /2 Z' °* Form NIS-2 Owner's Report for Repair/Replacement Activity ,As required by the provisions of the ASME Code Section XI-U Work Order Number 98693392-04 Sheet I of 2 1. Owner 2. Planit Unit Duke Power Company Oconee Nuclear Station 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/16/2005

3. Work Performed by -Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Main Steam, ASME Class 2 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)Snubber 2-OIA Lisega 614150/001 N/A N/A N/A Removed N/A 148 13-1`813 Snubber2-14A Lisega 615853/089 N/A UTC 1085722 UNK Installed N/A 148IBI--H81
7. Description of Work Replaced Lisega snubber containing AK350 fluid with one containing AP280.8. Test Conducted LI Hydrostatic n Pneumatic n Nominal Operating Pressure 1 Exempt 3 Other 'Visual Pressure PSI Test Temperature OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 98693392-04 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)0 0 0 0 0_CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed 4 & 2* g ,l K Date __ _ _ _ _ _Owner or Owner's Designee, Ttie CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of loaxiV ZW.-,&AJo' and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ,//. --' to I/Z -S' , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

___ __ __ __ __ __ __ __ __ Commissions A )E /hspector's Signature National Board, State, Province, and Endorsements D ate _ _ _ _ _ _ _ _ _ _ _ _ Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI-U.Work Order Number 98720644-01 Sheet I of 2 1. Owner 2. Plant Unit 2 Duke Power Company Oconee Nuclear Station 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/16/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Main Steam, ASME Class 2 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section XI Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)New Miller cylinder on Miller 00051 N/AN/A JNK Removed N/A snubber 2-O1A-0-14011B-R14

_Hydraulic snubber Anvil 36133 N/A UTC 1081181 UNK Installed N/A upgrade kit 7. Description of Work Replace the existing New Miller cylinder witrh a Anvil Config. A 8. Test Conducted D Hydrostatic LI Pneumatic LI Nominal Operating Pressure I Exempt 3 Other Visual Pressure PSI Test Temperature OF Form NIS-2 Owner's Report for Repair/Replacement Activity ks required by the provisions of the ASME Code Section Xl Ace lWork OrdT CERTIFICArE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed Ai H i ap, A,4 Date _ _ _ _ _ _ _ _Owner or OwneAs Designee, T'le CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Aloxrh 4'.eoL../Q and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period /_ -2,_ -____ _ to Gu- Z/ .-o< , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions _ _ _ _ _ _ _ _ _ _ _ _ _ _Inspector's Signature National Board, State, Province, and Endorsements Date _ _ S_ _ _ _ _ Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number 98720644-02 Sheet 1 of 2 1. Owner 2. Plant Unit 2 Duke Power Company Oconee Nuclear Station 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/16/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Main Steam, ASME Class 2 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped v (Yes I No)New Miller cylinder on Grinnell 18613 N/A N/A UNK Removed N/A snubber 2-01A-0-1481A-H8A

_Hydraulic snubber Anvil 35553 N/A UTC 1048578 UINK Installed N/A upgrade kit _7. Description of Work Replace the existing New Miller cylinder witrh a Anvil Config. A 8. Test Conducted L Hydrostatic F]Pneumatic F]Nominal Operating Pressure LI Exempt M Other Visual Pressure PSI Test Temperature OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number 98720644-02 I Sheet 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)0 0 0 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are (correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed /Ae/; Date 1111,gP1'Owner or Ow er's Desig'ne'e, itle CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of A/otAo ' GeA1aL A- and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period //- to ,/- Z/ o0 s- , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. I Commissions ioe/ 1 S/A 7/&.-G _ ,ffi, ,,-cZims-pector's-Si-griature -National Board, State, Province, and Endorsements Date A/- Z__ _on _ _ Form NIS-2 Owner's Report for Repair/Rleplacement Activity As required by the provisions of the ASME Code Section XI._ ..Work Order Number 98720644-03 Sheet I of 2 1. Owner 2. Plant Unit 2 Duke Power Company Oconee Nuclear Station 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201 -1006 Seneca, SC 29672 11/16/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Main Steam, ASME Class 2 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped P (Yes/INo)New Miller cylinder on Grinnell 30996 N/A N/A UNK Removed N/A 1481B-H2A

_Hydraulic snubber Anvil 35594 N/A UTC 1050269 UNK Installed N/A upgrade kit _7. Description of Work Replace the existing New Miller cylinder witrh a Anvil Config. A 8. Test Conducted Dl Hydrostatic F Pneumatic I Nominal Operating Pressure Rl Exempt Z Other Visual Pressure PSI Test Temperature OF Form NIS-2 Owner's Report for Repair/FReplacement Activity As required by the provisions of the ASME Code Section Xl _I Work Order Number 98720644-03 Sheet 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)0 e e 0 0 0 0 0 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed $o Date _ _ _ _ _ _ _ _ _ _Owner or Owner's Designee, Tit CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of A-Or,4 C and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period .i/-zo6 to ,/-Z/ , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. £ Commissions tCi/~59 OAJ '--Inspector's Signature Date //-Z/ Or National Board, State, Province, and Endorsements Form NIS-2 Owner's Report for Repair/Rleplacement Activity As required by the provisions of the ASME Code Section XI-Work Order Number 98720644-04 Sheet I of 2 1. Owner 2. Plant Unit 2 Duke Power Company Oconee Nuclear Station 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/16/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Main Feedwater, ASME Class 2 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section XI Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)New Miller cylinuer 0-- Grinnell 18607 N/A N/A UNK Removed N/A 1480B-H6B

_ .Hydraulic snubber Anvil 36135 N/A UTC 1081152 UNK Installed N/A upgrade kit 7. Description of Work Replace the existing New Miller cylinder witrh a Anvil Config. A 8. Test Conducted D FHydrostatic [R Pneumatic FiNominal Operating Pressure L1 Exempt Other 'Visual Pressure PSI Test Temperature OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 98720644-04 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)0 0 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applj!cable Expiration Date Not Applicable Signed H o >,^Date 1111 leG Owner or -wner's Dsignee, Title~CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province Ofc:-,5^,f and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period Z/. ou to /--, -Z/ -rS , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property clarage or a loss of any kin arising from or connected with this inspection. Commissions oCy=/sm Inspector's Signature National Board, State, Province, and Endorsemnents Date /- /o Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI._ .Work Order Number 98720644-06 Sheet 1 of 2 1. Owner 2. Plant Unit 2 Duke Power Company Oconee Nuclear Station 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/16/2005

3. Work Performed by Type Code Symbol Stamp Not Ap licable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Coolant, ASME Class 1 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)New Miller cylinder on Grinnel N/AN/A UNK Removed N/A snubber 2-50-0-148 1A-H7 _Hydraulic snubber Anvil 36040 N/A UTC 1077063 UNK Installed N/A upgrade kit _7. Description of Work Replace the existing New Miller cylinder witrh a Anvil Config. A 8. Test Conducted L Hydrostatic L Pneumatic El Nominal Operating Pressure Lii Exempt Other Vrisual Pressure PSI Test Temperature OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed 4 /zd- Date __________

Owner or Owner's Designeefritle CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Ae,79 b and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period t/- o- -o to /-/ 5 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions I'Inspector Signature Date /__ -_ _/_ -C_., __ _National Board, State, Province, and Endorsements Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI-.Work Order Number 98720644-09 Sheet I of 2 1. Owner 2. Plant Unit 2 Duke Power Company Oconee Nuclear Station 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/16/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Spent Fuel Cooling, ASME Class 2 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section XI Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)New Miller snubber 56 Grinnell 18589 N/A N/A UNK Removed N/A 1478A-H 10 _Hydraulic snubber Anvil 36126 N/A UTC 1081141 UNK Installed N/A upgrade kit 7. Description of Work Replace the existing New Miller cylinder witrh a Anvil Config. A 8. Test Conducted L Hydrostatic Li Pneumatic L Nominal Operating Pressure Li Exempt Pressure PSI Test Temperature Z Other Visual OF h Form NIS-2 Owner's Report for Repair/Replacement Activity A's required by the provisions of the ASME Code Section XI CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed _ _ _ _ _ _ _ _ _ _ __ Date /Owner or Okner's Desiinee, -itle CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of , :6~ and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ,// Tv to //- _ , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions .JC W/A -7linispector's Signature National Board, State, Province, and Endorsements Date z/-Z/lJo Form NIS-2 Owner's Report for Repair/R eplacement Activity As required by the provisions of the ASME Code Section Xl.. .._ .Work Order Number 98720644-18 Sheet I of 2 1. Owner 2. Plant Unit 2 Duke Power Company Oconee Nuclear Station 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/16/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Coolant, ASME Class 1 5.(a) Applicable Construction Code: USAS 831.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes)I No)Snubber 2-50 Grinnell N/A N/A N/A UNK Removed N/A 1 480A-H9 Snubber 2-50 Anvi 35409 N/A UTC 1058400 UNK Installed N/A 1480A-1-9Ani350N/UC1080 UK IntleNA 7. Description of Work Replace the existing Grinnell snubber with a Config. A Anvil snubber 8. Test Conducted[D Hydrostatic R Pneumatic Pressure[] Nominal Operating Pressure l Exempt PSI Test Temperature Z Other 'Visual OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section Xl Work Order Number_98720644-1 8 I Sheet 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)0 e 0 0 e e 0 0 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed g 5 Date ___ __ __ __ __Owner or r's Designee itle-CERTIFICATE OF: INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,)w G and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period /-/.-o$ to ,/- Z/-o 0 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.-rsIaMpco'Sintre Date // -Z'r -oi Commissions dc., -ous National Board, State, Province, and Endorsements Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI ~1WW, rWork Ordlei-U,-Number I 98720644-19 Sheet 1 of 2 1. Owner 2. Plant Unit 2 Duke Power Company Oconee Nuclear Station 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/16/2005
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Coolant, ASME Class I 5.(a) Applicable Construction Code: USAS 1331.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For RIR Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section XI Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)Snubber 50 Grinnell N/A N/A N/A UNK Removed N/A 1 479A-H2A Snubber 50 Anvil 34149 N/A UTC 1082290 UJNK Installed N/A 1 479A-H2A 7. Description of Work Replace the existing Grinnell snubber with a Config. A Anvil snubber 8. Test Conducted D- Hydrostatic 1 Pneumatic Nominal Operating Pressure EI Exempt Other Visual Pressure ________PSI Test Temperature O______ F Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 98720644-19 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)0 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are (correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed > g !. 0 * ' Date A / 6 Owner o lOwner's Desigde, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of 1/,,,e1r & and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period i'-L.'-o3s to ,/-el.oor , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions -/C9*'.d/A' S-`4ip ctor's Signature National Board, State, Province, and Endorsements Date //-Z/-c'5 Form NIS-2 Owner's Report for Repair[Replacement Activity As required by the provisions of the ASME Code Section Xl.. _ ., IWork Order Number 98720644-20 Sheet I of 2 1. Owner 2. Plant Unit 2 Duke Power Company Oconee Nuclear Station 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/16/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Coolant, ASME Class 1 (a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)Snubber 50 Grinnell N/A N/A N/A UNK Removed N/A.479A-H3A Snubber 50 Anvil 36146 N/A UTC 1081813 UNK Installed N/A 1 479A-H3A Snubber Rod Eye Anvil N/A N/A UTC 1035572 UJNK Installed N/A 7. Description of Work Replace the existing Grinnell snubber with a Config. A. Anvil snubber 8. Test Conducted I Hydrostatic n Pneumatic LI Nominal Operating Pressure E Exempt Other Visual Pressure PSI Test Temperature OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section Xl CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed /4 <i(. d Date /____/ __ _ _Owner or Owner's Design6, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Acet ewg and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period A. z.. o < to ,/- 0 -o , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions A2c 'V y'5 )/ .'4 National Board, State, Provincc, and Endorsements 9 'Ispecr's Signature Date / A- Z/-_ _ _ _ Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number 98720644-21 Sheet I of 2 1. Owner 2. Plant Unit 2 Duke Power Company Oconee Nuclear Station 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/16/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Ap plicable 4. Identification of System, ASME Class High Pressure Injection

-High Pressure Portion, ASME Class 1 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)Snubber 51A Grinnell 4846 N/A N/A UNK Removed N/A 1 479A-H2A Snubber 51A Anvil 36148 N/A UTC 1082289 IJNK Installed N/A I1479A-H2A

7. Description of Work Replace the existing Grinnell snubber with a Config. A Anvil snubber 8. Test Conducted D- Hydrostatic L Pneumatic R Nominal Operating Pressure LI Exempt Other Visual Pressure PSI Test Temperature OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 98720644-21 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)0 0 e CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Appli -able Expiration Date Not Applicable Signed -141 Ad.~ A,& Date s/6O Owner or Ov er's Designee Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of AloerW> ,tsov and employed by HSB CT of Hartford, Connecticut have inspected the components describe-d in this Owner's Report during the period ,zoO to //- Z/ c, 0 _-, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with thei requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Fuithermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any qkind arising from or connected with this inspection.

,, ~~~Commissions J w Y ) S~cor's Signature National Board, State, Provinc.- and Endorsements Date /- Z /-° 0 Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI-U Work Order Number 98720644-22 Sheet I of 2 1. Owner 2. Plant Unit 2 Duke Power Company Oconee Nuclear Station 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/16/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Low Pressure Injection

-High Pressure Portion, ASME Class 2 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)Snubber 53A Grinnell 5866 N/A N/A UNK Removed N/A 1479A-HIC Snubber 53A Anvil 36150 N/A UTC 1082291 IJNK Installed N/A 1479A-HIC Snubber Rod Eye Anvil N/A N/A UTC 1053974 UNK Installed N/A 7. Description of Work Replace the existing Grinnell snubber with a Config. A Anvil snubber 8. Test Conducted Hydrostatic R Pneumatic LI Nominal Operating Pressure l Exempt Other Visual Pressure PSI Test Temperature OF Form NIS-2 Owner's Report for Repair/Replacement Activity%s required by the provisions of the ASME Code Section XI`IW I Work Ord(.lr Number I 98720644-22 I Sheet 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)0 0 e 0 0 e 0 0 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed zew JUD ; Date __ _ _ _ _ _ _ _Owner oi 1 Owner's liesign&, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of AJE-rJv .ez,,A-,o, and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period -.&- to ,-z -o ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.-spector's Signature Date v -2/-Commissions ,AC'%4* 4bS National Board, State, Province, and Endorsements Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI.Work Order Number 98720644-23 Sheet I of 2 1. Owner 2. Plant Unit 2 Duke Power Company Oconee Nuclear Station 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/16/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Bldg. Spray -Low Pressure Portion, ASME Class 2 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)Snubber 54B Grinnell N/A N/A N/A IJNK Removed N/A 1477-1_9A Snubber 541 Anvil 35543 N/A UTC 1051564 UNK Installed N/A 1477-H9A 7. Description of Work Replace the existing Grinnell snubber with a Config. A Anvil snubber 8. Test Conducted Hydrostatic LI Pneumatic 0 Nominal Operating Pressure L] Exempt §3 Other Visual Pressure _ PSI Test Temperature OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI JWork Order Number Sheet 98720644-23 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)0 G e CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applic-able Expiration Date Not Applicable Signed G i l Hi' ;4ffi -Date A// 10-A Owner or 0 ner's Designee, e CERTIFICATE OF: INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province Of :d~rv >lo!^- and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ,- ,O to A-z'/ O -s 0f- , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with thE~ requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measurers described in this Owner's Report. Fuithermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions S / y A S-C aspector's Signature National Board, State, Provinc.- and Endorsements Date // "Z-o f Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI L1w Work Order Number 98720644-24 Sheet I of 2 1. Owner 2. Plant Unit 2 Duke Power Company Oconee Nuclear Station 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/16/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Bldg. Spray -Low Pressure Portion, ASME Class 2 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)Snubber 54B Grinnell 5069 N/A N/A UNK Removed N/A 1 477-H-9B3 Snubber 54B Anvil 35507 N/A UTC 1051558 UJNK Installed N/A 1477-1-913
7. Description of Work Replace the existing Grinnell snubber with a Contig. A.Anvil snubber 8. Test Conducted E]Hydrostatic LI Pneumatic F Nominal Operating Pressure []Exempt 14~ Other Visual Pressure ________PSI Test Temperature OF______

Form NIS-2 Owner's Report for Repair/Replacement Activity A\s required by the provisions of the ASME Code Section Xl Work Order Number Sheet 98720644-24 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)0 0 e 0 e 0 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed _____ _____ ____ Date __ __ __ _Owner or Oner's Deigne itle CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Aw <,oV and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period t-zo- to ./- Z.'*-o C , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions _ _ _ _ _ _ _ _ _ _ _ _ _ _--twreetor's Signature National Board, State, Province, and Endorsements Date //- 2-1 -e 6 Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI.Work Order Number 98720644-25 Sheet I of 2 1. Owner 2. Plant Unit 2 Duke Power Company Oconee Nuclear Station 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/16/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Spent Fuel Cooling, ASME Class 2 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section XI Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)Snubber 56 Grinnell 4758 N/A N/A UNK Removed N/A I1478A-H9 Snubber 56 Anvil 35506 N/A UTC 1051557 UNK Installed N/A 478A-H9 Snubber Rod Eye Anvil N/A N/A UTC 1053974 UNK Installed N/A 7. Description of Work Replace the existing Grinnell snubber with a Config. A Anvil snubber 8. Test Conducted E Hydrostatic R Pneumatic Cl Nominal Operating Pressure R Exempt Other Visual Pressure PSI Test Temperature OF Form NIS-2 Owner's Report for Repair/Replacement Activity Aks required by the provisions of the ASME Code Section XI i14tWork Order Number Sheet 98720644-25 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)0 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applic-able Expiration Date Not Applicable Signed / > l eDate /Ja161/01-Ow~ner or Own&'s Designiee,Te CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Alc,, ereo and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period /-a/-O to / -Z/- S- , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

____ ___ ___ ____ ___ _ _ Commissions a) '4X O/,)' ee._'ctrsp Signatre National Board, State, Province, and Endorsements Date //- 2 -o -- Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASMIE Code Section XI Work Order Number 98701272-01 Sheet 1 of 2 1. Owner 2. Plant Unit 2 Duke Power Company Oconee Nuclear Station 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/16/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Low Pressure Injection

-Low Pressure Portion, ASME Class 2 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)7-j% Duke None None None 1970 Corrected N/A 1243&42 AX 7. Description of Work replaced bent hanger rod and installed new nuts 8. Test Conducted LI Hydrostatic n Pneumatic LI Nominal Operating Pressure L Exempt Other Pressure PSI Test Temperature OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 98701272-01 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to he attached)o Replace bent hanger rod (UTC 1054905)e Installed new nuts (UTC 1079284)e 0 e 0 0 I,, CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Date / -o Owner or Owner s Designee, Title CERTIFICATE OF' INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of t, and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 9f. Zf. s- to /aZ- 7. of , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions /c J/y4,, '-IIpeer's Signature National Board, State, Province, and Endorsements Date z o05 Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I Work Order Number Sheet I of 2 98719910 NA" 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/15/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class High Pressure [njection, ASME Class 2 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)2BP-17 valve Crane/Aloyco Unknown None N/A 1968 Corrected NO-= = -=7. Description of Work During inpection of the valve discs, Maintenance techs decided to replace the valve discs because of scratches.
8. Test Conducted MHydrostatic n Pneumatic

[ Nominal Operating Pressure El Exempt E Other Visual Pressure PSI Test Temperature `F Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASvIE Code Section XI Work Order Number Sheet 98719910 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)o Valve Male disc -stock code 75943 -UTC 0000926870 0 Valve Female disc -Stock code 77050 -UTC 0000926869 0 0 0 0 0 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are orrect and that this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed Xt JM (I _

  • a@ Date c_ _ _/J Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of .n/, and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period o1 -Ve-o5 to 0,- z o S- , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

ZL Commissions __ _ _ _ _ _ _ _ _ __J__ _1-hspector's Signature National Board, State, Province, and Endorsements Date _ _ _ _ 7_ _ _ _ Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASvE Code Section Xi.Work Order Number_ 98719910-01 Sheet 1 of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/1/2005 3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable

4. Identification of System, ASME Class High Pressure injection, ASME Class 2 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xi Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xi Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)Valve 2HP-17 Crane/Aloyco Unknown None N/A 1968 Corrected NO 7. Description of Work During initial inspection of the valve PM, maintenance techs found the bonnet studs and nuts slightly coroded 8. Test Conducted[]ydrostatic n Pneumatic

[]Nominal Operating Pressure []Exempt Z other Visual Pressure PSI Test Temperature OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I Work Order Number Sheet 98719910-01 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)o Body-Bonnet Studs -Stock Code 467112 -ULTC # 0001006458 0 Body-Bonnet Nuts -Stock Code 313135 -UTC #0001074344 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are c orrect and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed a fi$ccfDt z/0/J-A/ Owner or Owner's Designee, Title CERTIFICATE OIF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Jor?<et,¢ and employed by HSB CT of Hartford, Connecticut have inspected the o omponents described in this Owner's Report during the period /0 -.31-0of to /Zz > and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection., ~~~~Commissions J /<,St hispector's Signature National Board, State, Province, and Endorsements Date _Z_ 7__ _z Form N1S-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I Work OrderNumber 98719296-06 Sheet I of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/18/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Coolant, ASME Class I 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)2RC-68 Consolidated BL-08895 None None UNK -Removed YES 2RC-68 Consolidated BT-04976 None None 1979 Installed YES o Outlet Flange IJNK None None None UNK Installed NO Nuts for 2RC-68 Nuts for 2RC-68 UNK None None None UNK Installed NO Nutsfor RC-6 7. Description of Work Installed valve, serial number BL-08895, was removed for section XI testing. Replaced with previously tested spare, serial number BT-04976, from stock. Valve, serial number BT-04976 was removed from unit 1 and repaired on work order number 98693303.

Replaced 24 outlet flange nuts and 16 inlet flange nuts due to being unmarked or unidentifiable.

8. Test Conducted LI Hydrostatic LI Pneumatic E Nominal Operating Pressure FI Exempt 3 Other RCS Visual Pressure PSI Test Temperature OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number 98719296-06 Sheet 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)0 Outlet Nut Material -Stock Code # 131798 -UTC # 1057384 0 Inlet Nut Material-Stock Code# 131853 -UTC#s 1033140, 1033141, 1033144 and 1067856 e 0 e 0 0 0 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed -H__ Sr. Engineer Date 11/18/05 Owner or Owner's esignee, Title qj.S CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of t,&r1oe.M/#l and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 7-Z 0-- to 12./- of , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions A,1/2/ 4e-fnmpctor's Signature National Board, State, Province, and Endorsements Date 'Z-7-' 5 Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI-U l Work Order Number 98693303 Sheet I of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -0 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/17/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Apilicable
4. Identification of System, ASME Class Reactor Coolant, ASME Class I 5.(a) Applicable Construction Code: ASME Section III 19 65 Edition, 67 Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)Pressurizer Code Safety Valve Dresser BT-04976 n/a n/a 1979 Corrected YES (spare) _7. Description of Work Replaced disc (UTC 1068294), serial number ADQ-63.8. Test Conducted LI Hydrostatic FLPneumatic IiNominal Operating Pressure V3 Exempt Other Pressure PSI Test Temperature OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 98693303 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)o Replaced disc (UTC 1068294), serial number ADQ-63.0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed -Zt? , Sr. Engineer Date 1 1/17105 Owner or Owner's Designee, Title 0-0w CERTIFICATE OFINSERVICE INSPECTION 1, the undersigned, holding a valid commission issuecd by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Ac !,A , adepodbyHBC of Hartford, Connecticut have inspected the components described in this Owner's Report during the period _ZO to /Z_ / a 0 f , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the.Inspector nor his employer shall be liable in any manner for any personal injury or property dariage or a loss of any id arising from or connected with this inspection.

I, taCommiss ions teational In spect or's Signature National Board, State, Provinc, and Endorsements Date -Z-/o .< Form NIS-2 Owner's Report for Repair/R eplacement Activity As required by the provisions of the ASME Code Section XI-Work Order Number 98719299-07 Sheet 1 of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/16/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Coolant System, ASME Class I 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)2RC-66 Consolidated BW-08706 none none UINK Removed NO 02RC-66 Consolidated BY93618 none none UNK Installed YES binlet flange UNK none none none LINK Installed NO 7. Description of Work Valve, serial number BW-08706, was removed for ASME section XI testing. Replaced with new spare valve, serial number BY93618. Installed new inlet studs and nuts due to spare valve having through hole inlet flange.8. Test Conducted I Hydrostatic L Pneumatic Ei Nominal Operating Pressure LI Exempt 3 Other RCS visual Pressure PSI Test Temperature OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 98719299-07 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached).0 I o Replaced existing valve with a new spare from stock. stock code 550860, serial number BY9361/, UTC 1075070.0 Inlet stud material -stock code # 318736 -UTC # 951541, Inlet nut material -stock code # 131853 -UTC # 1067856.0 0 0 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed _ A Sr. Engineer Date 11/16/2005 a/ Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of , e>Co'w and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 7-Z'- ° to -Z-o -, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any maniner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

,______ _____ _ Commissions Y spector's Signature National Board, State, Province, and Endorsements Date 7Z-7-oi Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section Xl-Work Order Number 98712291 Sheet I of 2 1. Owner 2. Plant _ Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not App'icable

4. Identification of System, ASME Class Main Steam system, 2MS-153, ASME Class 3 5.(a) Applicable Construction Code: USAS B31.7 19 68 Edition, 06/68 Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 S Edition, 2er& Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)B to B_studs/thread rod Energy Steel UTC 1077726 N/A sc# 29739r 1 *lon/ia Installed NO B to B nuts Energy Steel UTC 1077724 n/a Sc# 319298 n/a Installed NO 2MS-153 Crane UNK UNK n/a n/a Corrected NO__ a __-7. Description of Work Replace body to bonnett bolting studs and nuts on 2MS- 153 valve. Replace Bonnett to Yoke bolting studs and nuts on 2MS- 153 like for like. All work completed under work order and existing plant procedures
8. Test Conducted[] Hydrostatic E] Pneumatic LI Nominal Operating Pressure LI Exempt ,; Other ICI)C TIOCL Pressure PSI Test Temperature OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number 98712291 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)0 0 0 0 e e 0 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Author' ation Number Not Applicable Expiration Date Not Applicable Signed___

_ 'we Date __ _ _ _ _ _Owr or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of c G and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 7- 4 , or to 12 -A VIf _ , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Fur:hermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions /AG1 Signature National Board, State, Province, and Endorsements Date , Z- /-go, Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section Xl Work Order Number 98670064-01 Sheet 1 of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/15/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Coolant, ASME Class I 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)Valve, 2RC-IV-58 KSB 1027469 193 stock code UNK Removed YES 305255 2RC-IV-58 KSB 460435/11 566 305255 1994 Installed YES 0Tube to Pipe Swagelok none none part number SS- UNK Installed NO Connector
  • 810-1-16W
7. Description of Work Replaced valve with like for like replacement along with a tube to pipe connector.
8. Test Conducted LI Hydrostatic LI Pneumatic FI Nominal Operating Pressure n Exempt E Other Visual Leakage Pressure PSI Test Temperature OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 98670064-01 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)o Replaced valve 2RC-IV-58 with a like for like. Valve item number DMV-678, stock code: 305255, UTC #: 830821.O Installed Pipe to Tube Connector.

Stock code: 338571, UTC #: 1081948.

  • Pipe to Tube adapter is class 2.0 0 e 0 0 ,0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed a / Sr.Engineer Date 11/15/2005 Owner or Owner's Designee, Title CERTIFICATE OF: INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of e and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period _- 7o ,- to 'Z- 7. or- , and state that to the best of my knowledge and belief, the Owner has performed examinations and taker corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions <,/C2,4z 6er'W.spector's Signature National Board, State, Province, and Endorsements Date ;Z- 7'..-°5 Form NIS-2 Owner's Report for Repair/Replacement Activity"is required by the provisions of the ASME Code Section XI iW'. lWork Order-m Number 1 98715637-01 Sheet I of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/18/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class High Pressure Injection, ASME Class 2 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)O detF UNK None None None UNK Installed NO Studs UKNn oeNn JK Isald N OInlet Flange UNK None None None UNK Installed NO Nuts 7. Description of Work Replaced inlet flange studs and nuts due to existing ones being lost or misplaced.
8. Test Conducted LI Hydrostatic E Pneumatic E] Nominal Operating Pressure L Exempt Z Other Functional Leak Test Pressure PSI Test Temperature OF Form NIS-2 Owner's Report for Repair/R'eplacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 98715637-01 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)o Inlet Flange Studs -Stock Code 297412 -UTC # 1074195 0 Inlet Flange Nuts -Stock Code 293556 -UTC # 1074343 0 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization N mber Not Applicable Expiration Date Not Applicable Signed 4 ( Z Sr. Engineer Date 11/18/2005 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of- ,oerv , and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period /__-__ to o , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_______________ _ Commissions _ __ __ __ ___ __ __Inspector's Signature National Board, State, Province, and Endorsements Date 2- 7-or Form NIS-2 Owner's Report for Repair/Replacement Activity 3 required by the provisions of the ASME Code Section XI I A Work Order Number 98719129-03 Sheet I of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/1/2005 3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 2820 1-1006 Expiration Date Not Applicable

4. Identification of System, ASME Class Steam Generator

-Reactor Coolant System, Feedwater System, ASME Cl ass 1 5.(a) Applicable Construction Code: ASME Section i1ll- 19 of Edition, S Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)2B Steam Primary Hand B&W Canada 006K04 208 2003 Corrected YES Hole Hex Nut =_ _A. Description of Work Replacement of 2B Steam Generator primary hand hole hex nut.U. Test Conducted El Hydrostatic n Pneumatic OI Nominal Operating Pressure EL Exempt ZJ Other Dressure L/9 sk' 1 A Form NIS-2 Owner's Report for Repair/Replacement Activity 3 required by the provisions of the ASME Code Section Xl Work Order Number Sheet 98719129-03 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)o Nut, Hex, Type: Heavy Hex, 1 1/4" -8UN 2B, SA 194 Gr B7, Dimensional Standard: ANSI B 18.2.2, Stock Code 557797.0 0 G 0 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed / Date _ _ _ __1_ _h/wner or Owner's esignee, Title CERTIFICATE C)F INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of A/ae-. 'oZaA'. and employed by HSB CT: of Hartford, Connecticut have inspected the components described in this Owner's Report during the period, ,i--: ~- to ' .-,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with fe requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the tv nspector nor his employer shall be liable in any mariner for any personal injury or property damage or a loss of any Kind arising from or connected with this inspection. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ C om m issions _ _ _ _ _ _ _ _ _ _ _ _ _pector's Signature National Board, State, Province, and Endorsements Date /2-<- OS Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI-q --Work Order Number 98705693 Sheet 1 of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 10/30/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class RCS, ASME Class 1 (a) Applicable Construction Code: ASME Section III 19 ' Edition, A/o Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)CRDM #63 Diamond Power UNK UNK UNK UNK Installed YES 08 CRDM hold FANP UNK N/A UTC 1056490 UNK Installed NO down bolts 3 1 (2 piece) nut FANP UNK N/A UTC 1075364 UNK Installed NO ring 7. Description of Work Remove CRDM #63 for ISI and re-install.

Replace CRDM hold down bolts and nut ring with new ones per station practice for this component.

8. Test Conducted[] Hydrostatic LI Pneumatic 3 Nominal Operating Pressure F Exempt n Other Pressure 2155 PSI Test Temperature

-532 OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI-Work Order Number_98705693 I Sheet 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)o 8 new CRDM hold down bolts installed, old ones discarded per standard practice. Material SA-453, Gr. 660. UTC 1056490, (S/N's GN-6307, -6017, -6103, -6214, -5991, -6229, -6338, -6231)0 1 new (2 piece) nut ring installed, old one discarded per standard practice. Material SA-320, Gr. L-43. UTC 1075364, S/N 9717-GN-84 0@0 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Aut ion Number Not Applicable Expiration Date Not Applicable Signed _______ Date 10/30(1931 Owner) ver's Designee, Title-t CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,AJac, 3 y G and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 0/- S' -oo to , ,- ' , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. -l spector'Date . ?-cf Commissions ,/C,'Sj >!5 s Signature National Board, State, Province, and Endorsements Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI-U Work Order Number 98757305 Sheet 1 of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 10/30/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date_ Not Applicable
4. Identification of System, ASME Class RCS, ASME Class 1 5- .So- LAo (a) Applicable Construction Code: ASME Section III -19 Jl Edition, /ro0 Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section XI Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes /No)CRDM #41 Diamond Power UNK UNK UNK UNK Installed YES o8 CRDM hold FANP UNK N/A UTC 1056490 UNK Installed NO down bolts e 1 (2 piece) nut FANP UNK N/A UTC 1075364 UNK Installed NO ring ._= =_a I S -U a a. U -7. Description of Work IRemove CRDM #41 for internals repair and re-install.

Replace CRDM hold down bolts and nut ring with new ones per L4station practice for this component.

8. Test Conducted[jl Hydrostatic l Pneumatic M Nominal Operating Pressure [n Exempt n Other Pressure 2155 PSI Test Temperature

-532 OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI-Work Order Number 98757305'Sheet 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)o 8 new CRDM hold down bolts installed, old ones discarded per standard practice. Material SA-453, Gr. 1560. 6 from UTC 1056490, (S/N's GN-5998, -5978, -6187, -6261, -6247, -6279, -6280, -6023)1 I new (2 piece) nut ring installed, old one discarded per standard practice. Material SA-320, Gr. L-43. urc 1075364, (S/N 971 7-GN-79)0 0 e 0 0 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed _ _ _ _ _ _ _ _ _ _ _ _ _ _Date 10/3012005 Owner or gner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of AV ,ez~jv and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period /__-o __ -a -to .2 -7.cr- , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. -W. II--ilnspecti Date 7--°<f Commissions xo's Signature National Board, State, Province, and Endorsements Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI-U Work Order Number 98757346 Sheet 1 of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 10/30/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class RCS, ASME Class 1 5.s'v 7 ,,hrhs (a) Applicable Construction Code: ASME Section III 19 65 Edition, -#A*' Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)Reactor Vessel Head o Stud #29 B&W 204-51-29 N/A J0e = Removed NO B&W 204-51-62 N/A A T'c 812ti0 Installed NO 0 Stud #29 _7. Description of Work Replace reactor head stud at stud location 29.-JQ.8. Test Conducted n Hydrostatic

[] Pneumatic Z Nominal Operating Pressure LI Exempt L1 Other Pressure 2155 PSI Test Temperature -532 OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI _Work Order Number 98757346 I Sheet 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)0 0 0 0 e 0 0 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authoriation Number Not Applicable Expiration Date Not Applicable Signed __________ Date 10/30,/2005 Owne ) ner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of AJoxey -and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period /B. / -o r to lz- 7-ps- , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions /9o 'wA'4 c-Tn-spector's Signature National Board, State, Province, and Endorsements I Date ___-___7 _____ Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI IWork Order Number 98720378 Sheet 1 of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/2/2005 3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable

4. Identification of System, ASME Class Valve Tag # 2LP-28 in the LPI System, ASME Class 2 5.(a) Applicable Construction Code: ASME Section HI 19 68 Edition, 06/68 Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section XI Code Case(s) None 6. Identification of Components Name of Component Name of Manufacturer Manufacturer Serial Number National Board No.Other Identification Year Built Corrected, Removed, or Installed ASME Code Stamped (Yes I No)B/Bvstuds&onuts UNK N/A N/A N/A N/A Removed NO Installed New IJsn Het#195 TC# Isald N 7/8" B/B studs Mackson Heat #719550 0001081618 l l Galled NO Installed New Mcsn Heat Code# IJTC# NA Isald N 7/8" B/B nuts JSY 0001076713
7. Description of Work Replace body/bonnet studs and nuts on 2LP-28. Work completed under work order and existing plant procedures He .. .8. Test Conducted aI Hydrostatic LI Pneumatic

[1 Nominal Operating Pressure LI Exempt 3 Other FN Leak Check Pressure PSI Test Temperature OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASMUE Code Section XI JR t CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xi.Type Code Symbol Stamp Not Applicable Certificate of Authorization Numbef Not Applicable Expiration Date Not Applicable Signed , AD S _ T f t c !7 Date //- ?- __o la _;0 we r'wcV ~sgeTte7 -CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of o ,wVou_4' and employed by HSB CT Of Hartford, Connecticut have inspected the components described in this Owner's Report during the period A/_ 9 to /Z 0 a , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures; described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Inspector's Signature Commissions National Board, State, Province, and Endorsments Date I I Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI.._ ..Work Order Number 98757040-03 Sheet I of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/9/2005 3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable

4. Identification of System, ASME Class High Pressure Injection, ASME Class 2 5.-(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)Valve -2HP-31 Fisher 4768610 None None 1969 Corrected NO 7. Description of Work Work Order # 98757040-03 was written for a seat leak. The valve plug/stem assembly was replaced.8. Test Conducted Hydrostatic 2Pneumatic LI Nominal Operating Pressure R Exempt " Other Visual Pressure PSI Test Temperature OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number 98757040-03 I Sheet 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)o Valve plug/stem assembly, Stock code # 18079, UTC # 0001078058 0 0 Q e CERTIFICArE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable S igned'U..

No £X 1 -ztc 5zds Date / / /5 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of >6 e;I CA 7zlWe and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 0Z^ r 32 to AZ.-S-C r- , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions Ak /11 'C//s)Ar Inspector's Signature National Board, State, Province, and Endorsements D ate _ _ _ _ _ _ Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number 98719909-01 Sheet 1 of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/1/2005 3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable

4. Identification of System, ASME Class High Pressure Injection, ASME Class 2 5.-(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xi Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)Valve 2HP-18 Crane/Aloyco Unknown None N/A 1968 Corrected NO 7.Dsrption of Work During initial inspection of the valve PM, maintenance teclis found the bonnet studs and nuts slighrtly coroded Test Conducted[1 Hydrostatic L Pneumatic n Nominal Operating Pressure L Exempt EjOther 'Visa Pressure PSI Test Temperature OF U Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI _I Work Order Number 98719909-01 Sheet I 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)0 Body-Bonnet Studs -Stock Code 467112 -UTC # 0001006458 e Body-Bonnet Nuts -Stock Code 313135 -UTC # 0001074344 0 e 0 e 0 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed J. G _ Date -/ ____7/ Owner or Owner's Designee, Title_CERTIFICATE 01: INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of e C~c4vo and employed by HSB CT of Hartford, Connecticut have inspected the components describe(I in this Owner's Report during the period /c -< to _ ___ ___ , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions -xrupctor's Signature Date /Z 8- '5-National Board, State, Province, and Endorsements Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I Work Order Number 98720097-01 Sheet I of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/8/2005 3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable

4. Identification of System, ASME Class High Pressure Injection, ASME Class 2 5.(a) Applicable Construction Code: ASMESectionIII

_ o19 86 Edition, 1988 Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)Valve-2HP-120 CCI 706571-1-1 None None 1998 Corrected No 7. Description of Work Work Order 98720097-01 was written for the valve PML During the PM, Maintenance techs identified that the spindle was damaged from the flow conditions.

8. Test Conducted-rI Hydrostatic n Pneumatic LI Nominal Operating Pressure L Exempt X:] Visual Pressure __ __ PSI Test Temperature OF I Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I Work Order Number 1 Sheet 2 of 2 98720097-01
9. Remarks (Applicable Manufacturer's Data Reports to be attached)0 Valve spindle. serial # 600346. Duke Stock Code # 486801,. UTC # 0001085423 0 e 0 e 0 0 0'0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signe ae<2 t gogl- 4 e+ Date /I/ ///' Owner or Owner's Designee, Title_ I CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Atb -6weo~s4V and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ./.or to /Z- -e. , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from o onnected with this inspection.

Commissions Inspector's Signature National Board. State, Province, and Endorsements Date _ z-_ _-_ _ _ Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section Xl-Work Order Number 98693392-04 Sheet I of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/16/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Main Steam, ASME Class 2 5.(a) Applicable Construction Code: USAS B331.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section XI Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)Snubber 2-01 A Lisega 614150/001 N/A N/A N/A Removed N/A Snubber 2-0 IA Lisega 615853/089 N/A UTC 1085722 UNK Installed N/A 7. Description of Work Replaced Lisega snubber containing AK350 fluid with one containing AP280.8. Test Conducted E1 Hydrostatic E1 Pneumatic al Nominal Operating Pressure E Exempt Z Other Visual Pressure __ __PSI Test Temperature OF

,rm NIS-2 Owner's Report for Repair/Replacement Activity ,,s required by the provisions of the ASME Code Section XI Work Order Number Sheet 98693392-04 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)0 0 0 0 0 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed /_ _ #% r's 46ftis Date _______Owner or Owifer's Designee, fritle CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of AvoAw wG2AAJ and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period //. 2/- r to o Z -0o so , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. ____ ___ ___ ____ ___ _ _ Commissions A) /Y '/ )/ Ad&nspector's Signature National Board, State, Province, and Endorsements Date //-_ _ _ _ 5 Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI-U Work Order Number 98656689-01 Sheet I of 2 1. Owner 2. Plant Unit 2 Duke Power Company Oconee Nuclear Station 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/19/2005

3. Work Performed by Type Code Symbol Stamp Not Ap 31icable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Coolant, ASME Class 1 5.(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)New Miller cylinder on Grinnell 18597 N/A N/A UNK Removed N/A snubber 50-0-1481A-HI _Hydraulic snubber Anvil 35407 N/A UTC 1042692 UNK Installed N/A upgrade kit 7. Description of Work Replace the existing New Miller cylinder witrh a Anvil Config. A 8. Test Conducted D Hydrostatic R Pneumatic F]Nominal Operating Pressure LI Exempt 3 Other Visual Pressure PSI Test Temperature OF Form NIS-2 Owner's Report for Repair/R'eplacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 98656689-01 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)0 0 0 0 e CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed j i Date 'z// i/05 Owner or Owner's D Ignee, Title CERTIFICATE OF: INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of AJo er,'v Geo , and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owners Report during the period Li- 'go .r to ,Z- Z -e.I , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _ ___ Commissions /'A'/Adc Inspector's Signature National Board, State, Province, and Endorsements Date '"o Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section Xi.I Work Order Number 98719745 Sheet I of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 1 11/20/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class High Pressure Injection, ASME Class 2 5.(a) Applicable Construction Code: USAS B331.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)2HP- 16 valve Crane/Aloyco Unknown None N/A 1968 Corrected NO 7. Description of Work During inpection of the valve discs, Maintenance techs decided to replace the valve discs because of scratches.
8. Test Conducted Hydrostatic El Pneumatic Ei Nominal Operating Pressure LI Exempt 0 Other Visual Pressure PSI Test Temperature OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section Xi l Work Order Number 98719745 Sheet 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)o Valve Female disc -Stock code 77050 -UTC 0000926869 0 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp Not Applicable Certificate of A thorization Number Not Applicable Expiration Date Not Applicable Signed ____ Date / 1 M / d_ _77~wner or Owner's Designee, Titifi CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Agber 6v,&ed6'.t and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period / o to -,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions /'/kdc-~--' Inspector's Signature National Board, State, Province, and Endorsements Date /-J3-O6 FORM IS OWNERS RPOJIFR PARs OR REPLACEMENS As Requrd By The Provistons Of heASIE Cod Section 1 I---.i -1. Owner Duke Power Company Addre 528 Church Set, Chalotte, NC 28201I1006 1a. Date C6Y-1/3-0SL Sheet -L of J 2. Plant Addres5 2a. Unh Oconee Nuclear station 7800 Rochestsr Hwy. ¢Sae S.C. 29672 01 03 O Shared (spe* U^, )Sa. Work Order # ____ ___ __3. Work Performed By Duke Power Company Address 52 .8. Church Street Chroth, NC 28201-1008 Type Code Symbol Stamp WA Authoflwao No. WA Eqplraton Date WA 4. Identfficaton of Syste ms 51/4 Led/ J 1 CWWn Repair Organiation Job #A//4 3b. NSMorMM#s. (a) Appucable Consction Cole4 Z 3 / 1 Z Eo Addenda, KJ/a Code Cases (b) Andab Ed uonof Seion Umd for epr or Replacemn 1989oAddenda 41992 tshou 1.992 Addenda for C14.s NO and 6. Identicaton of C opnet Repalrd orepued and ReplemtCmnets Columnf IolwmZ CoCU= Cohn 4 OUWS 0OI.6 CCU=? cow=$Mauatue atIonal MMt Year ASIA! Code Name of Component Name of ace Number Board Ide aon Bunlt Sed y orno)A <2-O//9- 0OX No Re o N pO00Reard 0N/4706-/ 11M .RN0 110 [ yestg I=lO~C ORepalred O No c 8 Replaced_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ -0 R ebtacem ent 0) Yes 0 Repio No D .Repalaed O No_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ -R eblace mnent U Y es 0 RepaiNo 0 Rep W El Oyes F ORelaced of2-_ _ _ __ _ _ _ _ R 0 yes Page I of 2 Form NIS.2 (Back)NOTE: Supplemental sheets In form of lists. sketches, or drawings may be used, provted (1) size s 8 112 in. X 11 In. (2) Information In Items 1 through 6 on this report is Included on each sheet aod (3) each sheet Is numbered and the number of sheets Is recorded at the top of thits form.7. Dscripto orf WO 2s & 11D4) &456W iM ct2 -014.- 0-/41/01 °v'7'8. Test Conducted 0 "tostaft 0 Pneumatic 0 Nominal Operating Pressure 0 Other I Exempt'Pressure _____psig Pressure __ps Pressure psig Test Temp. OF Test Temp. OF Test Temp. *F 9. Remaks S/M I (Appflcable Manufacturet's Data Records to be Attached)>1* CERTIFICATE OF COMPLIANCE We ctify at the statements made In the report are conrect and this repaIr or replacement confoins to the rules fi the ASME Codo, Secion XI.Wpe Code Symbol Stamp WA No. WA -Expiration Date WA 8 -od(( /t Da taSm-Z2AU CERTIFICATE OF INSERVICE INSPECTION I. the Uoderaigned, holding a valid by the National Board of Boger andPqre Vessel pectors and t State or Prorid e of / U --- -and employed by -_ C7 have Inspected the components described In t Owners Report durt the period -/V.?,o that to the best of my knowledge and belief, the Owner has perormed examrnation and takeIn this Owner's Report In accordance wdth the requiroments o the ASME Code.Secflon Xl.ES inlng this cerlificate, neither the Inspector nor his employer makes any warranty, expressed or h1plied, N¢l 9 the Oxamatjons and corrective measures dscrbd In tis Owners Report. Furthermore, neither the o~r nor his employershall boe iable In any manner for any personal injury or property damage or a loss of any idan from or connected with this Inspection. mi/ssions_ Date^ 0r lntr National Board, State. Providence and Endorseme nts ot tnI 2 11-FOPR NIS'2 OWHEIR'S DPDM D D4 O REPILACEMI. As Requtrd By The Provistobs Of Th@ ASME Code Section X 9 tI 64&4ze*z'1. Owmer DukePowerComny Addrss 528 Church Sr, Charotte, NC 2820t1006 2. Plant Oconee NuclearSttion Address 7800 Roclester Rwy. Suee"a S.C. 29672 la. Date fi/z=Sheet / ot ,/-2a. Unt 03 0 Shared (spe Un )3a WorkOrder# 96'6Z7-3'1-o/3. Work Perforned By Duke Power Company Address 628 Church Stret Ca t NC 28201.1008 Type Code Symbol Stamp WA Autahoon No. WA Expkaton Date WA 4. Identiflcston of System.. 4-' fy*E ;$.d A 5. (a) Applicable Conscon 7 19c Addenda, (b) Appcable Edion of con UtMzodf RepairsorRepl mt 1989, NoAddenda 41992 CC and tbeI? suppotS.6. Identcaton of Conents Repaired or Replaced and Replacement Components RepaIr Organization Job #/V/3b, NSM or MM #Coda Cases tbl-cugh 1992 Addenda for Class MC and Columnl coma CI 2 ou COW lm4 (5 Io6 Ock 7 COW= S cumcurr atoYearpird, ASM"!Code Name of Component Name of Msnufacture b Board IdentieaRon l eBulot Stamped_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ N u m b e r ubM NU e l c m e t ( e o r n o )A ZRep-7'd -. ORe 0No O_ _ R__cement 0 Yes C .eORed O No 0 Repl_ e.-Retnt O Yes C0 R epad n0 No c o Replacd-0 Retament 0 Yes D 0 Repkwrd D ORepalaed O No 0 Repabod_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ -0 R e ~ a c m e n t0 Y e s 0 Repaw reN F l .p d l I No 2.~Page 1 ol12 Form NWS-2 (Back)NOTE SuPPlemental sheets In forn of fists, sketches, or drawings may be used, provlded (1) size is 8 1/2 in x 11 In. (2) Information In ftem3 1 through 6 on this report Is Included on each sheet ancd (3) each sheet Is numbered and the number of sheets Is recorded at the top of thls form.7. Description of Work -/. 4 /Ag7> r 4 A- AEW'W7' 4J e /a kr 8. Test Conducted: 0 1-1dtostatic 0 Pneumauc 0l Nominal Operating Pressure (O Other Ea Eempt Pressure psig Test Temp. F Prssure pstg TestTemp.

  • F Pressure psig Test Temp. F 9. Remarks (Appilcablo Manufacturers Dat Records to be Attached)CERTIFICATE OF COMPLIANCE Wo cery that the statements made In the report are corre:t and ths repalr or replacement conformes to the nXic of the ASME Code. Seco Xi.Type Code Symbol Stamp WA ertfte of Authorzation No. WA Expiration Date WA SMen a,.0 ig-rtZ/f eDate ;ZZae/Ownr Owrner '8 Ise .il CERTIFICATE OF INSERVICE INSPECTION I, the undersI ned holdt a vaSd bssed by t Natonl Board of Bolor and P esso l Pctors and theState or Provfdence

& and employed by-, -have Inspected the components desc d In thls Owners Report during the peW I oJN and stato that to the best of my knowledge and belief, tho Owner has performed examlnaotns and odona sver moasures descibed In tis Owners Report hI accoorance with the requtroments of the ASME Code.y on this certifcato, neither the Inspector nor his employer makes any warranty, expressed or Iplied.W"MV the examinatns and corrective measures descriel hI ti Owners Report Furthermore, neither the nor his employr lhd be fiable I any manner for any porsonal Injury or property damage or a k ss of any WD from or connected with this Inspection. Co issosR FL / 2 AS ----sii S ture Natial Brx ite'.Povnp and Enosm ents'te__________ 0o 012..._ FORM MIS.2 OWrNyE PS REo IW- R4 Or REPLACEMNTS As Roqtlred By The Poisn Of The AMEI Code Secton )a f 1. Owner DukePower Compny Addres 52 S. Church Street, Chatotte, NC 28201-1006 Z Plant OconeelNucleartation Address 7800 Rochester Hwy. Sdnecaj 8.C. 29672 la. Dato II1 -iia _q Sheet L of ° -2a. Unit 01 O s O Shared (specy unts )3. Work Performed By Duke Power Company Address 52 8. Church Stree Charlott, NC 2821-1008 Type Code Symbol Stamp WA AuihoftFaon No. WA plration Daoe WA 4. Identffication of System ty Oe.4 j CftAass s 5. (a) AppUcable Constr.t7onCode 3 -7 19- Addenda,.(b) Apptableio of S on Utilzed for Repali or Replacement 1989, NoAddenda (1992 CC ad to~fx C sppooa.t 6. Ident~fcton ot Componens Repaired or Repae and Replacement Components 3a Wok Order # , 3b. NSM or MM #, Repair Organizaton Job #tlI1 CodA CAsAs throush 1992 Addenda for Class MO and column I COW= I oua ( Ooumn-6 I oumns I call Ooma? I Column i ManfatuerRSe~SIrv ASUH Code Name of Component Name of anufer l ft Number Identcation Btilt Re i or Stamped_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _~~~ O M__ _ _ _ _ _ N m e _ _ _ _ _ _ _ e ~ e e t ( e o r n o )A .Re .y A ______ I \t__O 24Z-'Ps /ft- _o B OO nt O Yes IORepad O No B O Replaced 0 Replaceent d Yes Repared_ 0 ONo E .~pio OOPo 0 Rephaement 0 Yes_ : gOpReplod ONo F O Repalaed Pge 1 of Yes Form NIS-2 (Back) ..i NOTE: Supplemental sheets In form of lsts, sketches, or drawings may be used, provide (1) size is 8 112 In. x 11 In. (2) InformatIon In Items 1 through 6 on this report Is Included on each sheet and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.7. DesOripton ot Work. Vi i ck #' A t- ek , Z A-. t. \8. Test Conducted: 0 HydcostaUc 0 Pneumatic 0 Nominal Operating Pressure 0 Other I7 Exet Pressure psig Test Temp. ._ *F Pressure psWg Test Temp. OF Pressure pstg Test Temp. _O*F 9. Remaut //A (Applicable Manufacturees Data Records to be Attached)CERTIFICATE OF COMPLIANCE eo if that Whe statements made In the report are correct and this repair or replacement confonrs to the nre Of the ASME Code. Section Xl.Type Code Symbol Stamp WA Cetficate of Authorization No. WA Expiration Date WA B6giSod &A-. 5Pec'av/.z: 7'~ DateZ o-A -O /Owner or Owner'8 Desgne Tite CERTIFICATE OF INSERVICE INSPECTION I. the uOderslgned hodit a valid com Issued by the Nadwona Board of Boller pdPserOVasesl tors and the State or Prodence o f E)A and emploed by-have inspected the components descried In th Owners Report durn the pOriod U and State that to the best of my knowledge and belief, the Owner has performed examlnal"on kWnd 0 COreW measures described hI this Owner's Report In acooodance with the requiroments of the A5ME Code.ctiton XI.BY $n9gthis certificate. neither the Inspector nor his omploew makes any waranty, expressed or Implied.W~rt* the examinations and corrective measures dscribod In is Ownes Repor Furthermore, nolehr the tr nor hiemployer h be liable In arny manner for any personal Inwuy or property damage or a loss of any dafthIng from or connected with this Inspection. Corruissions CZ 12 4/ A4 A.§ X 9 A ftnature Nat I r te, P an rm ents It/o____a*^^ 7 ViC U FORM NIS-2 OWNER'S REPORT FOR REPAIRSgOR REPLACEMENTS As Required By The Provisions Of The AS/E Code Secion X , I: 1. Owner Duke Power Company : Address 526 S. Church Street, Charlotte, NC 28201-1006

2. Plant I Oconee Nuclear Station Address 7800 Rochester Uwy. Sdnecai S.C. 29672 I I ... ...I* ia: Date ' I 2 , J7 Sheet L of.....of J -2a. Unit 01 03 O Shared (specify Units .. )3. Work Performed By Duke Power Company Address 526 S. Church Street, Charlotte, NC 2820141006 Type Code Symbol Stamp WA Authorization No. WA ExpImation Date WA 3a Work Order # :?,e3-.Repair Organization Jqb #3b. NSM or MM#__ ___I A. Identifinntinn of AvqtArm L? I c~tm _i.--~w z wu e -. _ -am.. -* -_ __ _ _ _ _ _ _ _5. (a) Applicable Construction Code B 31. 19AL EditionR-69 Addenda. _Code Cases (b) Applicable Edition of Section Xi Utilized for Repalrs or Replacements 1989, NoAddenda

<(1992 through 1992 Addenda for Class MC and CC and their supports.)

6. Identification of Components Repaired or Replaced and Replacement Components Column l ; Column I Column 3Column4 ColunS I Col Columni I Column 8 Page 1 of 2 Form NIS-2 (Back)it\}NOTE: Supplemental sheets In form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 In. x 11 In. (2) Inforimation In Items 1 through 6 on this report Is Included on each sheet, and (3) each sheet Is numbered and the number of sheets Is recorded at the top of this form.7. Desrption Of WIo; aL~s ..L &I .eN c..-..& : .1~z ss-(\ .k L----8. Test Conducted:

0 Hydtostatlc 0 Pneumatic E Nominal Operating Pressure 0 Other Exempt Pressure psig Pressure psig Pressure _ prig Test Temp. OF Test Temp. °F Test Temp. F LVCWZ I Q(nC).S QgRAmjarkn

  • I-32A,,o_W~ore&.C Av.WL\t~ -i., ._...KI 4 'AS LC-7(L (Applicable Manufacturmers Data Records to be Attached)-CERTIFICATE OF COMPUANCE We certify that the statements made In the report are correct and this repair or replacement conforms to the rules of the ASME Code, Section Xl.Type Code Symbol Stamp NWA Certificate of Authorization No. NWA Expiration Date N/A Signed- I i e'> c c<\ Ries I Datea L2Jl i Owner or Owners Designee, Title CERTIFICATE OF INGIERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Providence of AJA7?"6-e'A"v and employed by oYS' c /have inspected the components described in this Owner's Report during the period <'-te4*>to 'Z 3- and state that to the best of my knowledge) and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Repoirt in accordance with the requirements of the ASME Code, Section Xi.By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report FurthenTme, neither the Inspector nor his employer shall be liable In any manner foir any personal injury or property damage or a loss of any kind arising from or connected with this Inspection.

1Inspector's Signature Date /Ze- °c Commissions A/C/ t9<v5J-National Board, State, Providence and Endorsements I a Page 2 of 2 Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI-U Work OrderNumber .98693302 Sheet I of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -0 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/17/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Coolant, ASME Class 1 5.(a) Applicable Construction Code: ASME Section III 19 65 Edition, 67 Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I NO)Pressurizer Code Safety Valve Dresser BL-08890 n/a n/a 1970 Corrected YES (spare) _7. Description of Work Replaced disc (UTC 1068296), serial number ADQ-65.8. Test Conducted[I Hydrostatic
1 Pneumatic LI Nominal Operating Pressure Exempt L1 Other Pressure PSI Test Temperature OF Form NIS-2 Owner's Report for Repair/leplacement Activity As required -by the provisions of the ASME Code Section Xl Work Order Number Sheet 98693302 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)o Replaced disc (UTC 1068296), serial number ADQ-65.0 e CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are (correct and that this conforms to the requirements of the ASME Code, Section XI.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signedr2wnrs~sgne TitleQ -Sr. Engineer Date 1 1/17/05 CERTIFICATE 01: INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province Of Act, ,er,,V G~-> and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 7- ?-8 ->, SI to o- _ f ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Fuilhermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damnage or a loss of any kind arising from or conne ted with this inspection.

5 ~~~~Commissions vz;PJ s W'-"- or's Signature National Board, State, Province, and Endorsements Date / Z/ -or Form NIS-2 Owner's Report for Repair/R'eplacement Activity As required by the provisions of the ASME Code Section XI.. .I Work 'Order Number 98719295-04 Sheet I of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/17/2005

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Coolant, ASME Class I (a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section Xl Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)2RC-67 Consolidated BL-08891 None None 1970 Removed YES 2RC-67 Consolidated BL-08890 None None 1970 Installed YES 7. Description of Work Installed valve, serial number BL-08891, was removed for section XI testing. Replaced with previously tested spare, serial number BL-08890, from stock. Valve, serial number BL-08890 was removed from unit 1 and repaired on work order number 98693302.8. Test Conducted E Hydrostatic LI Pneumatic l Nominal Operating Pressure El Exempt Pressure PSI Test Temperature Other RCS Visual OF Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I Work Order Number 98719295-04 Sheet 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)0 0 0 0 0 0 0 0 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Signed 7 6/ /Not Applicable Expiration Date Not Applicable Sr. Engineer Date 11/17/2005

<I Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Al,-.erl, ef404 ja and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 7-Z__ _-or_ to /<Z-/-o'r , and state that to the best of my knowledge and belief, the Owner has performed examinations and taker corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Rdport. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. g___ _ __ __ _ __ _ _ Commissions _ _ _ _ _ _ _ _ _ _ _Mi6yector's Signature National Board, State, Province, and Endorsements Date /2- c.;.n-. Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI.!.Work Order Number 98732127-01 Sheet <j3g I of 2 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS -2 526 South Church Street 7800 Rochester Hwy Date K Charlotte, NC 28201-1006 Seneca, SC 29672 2/9/2006 3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable

4. Identification of System, ASME Class 3 See. 9J.fevvmArk5 High Pressure Injection system, Letdown Cooler, ASME Class I o Shee+ 2 of 2 5.(a) Applicable Construction Code: ASME Section III 19 80 Edition, Sum. 8O Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.(c) Applicable Section XI Code Case(s) None 6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)2A LetdownGrhm--

CooleManufacturing 44773-1 12767 None 1983 Removed YES Cooler (1) ~C orp.__ _ _ _ _ _ _ _ _2A LedownGraham oow Manufacturing 44773-2 12768 None 1983 Installed YES Cooler (2)C i *h -h I I 7. Description of Work\1 ,"Replacement of 2A Letdown Cooler with used spare cooler of same design.8. Test Conducted FII Hydrostatic FII Pneumatic LI Nominal Operating Pressure Ei Exempt Pressure PSI Test Temperature _3 Other functional leak check OF Form NIS-2 Owner's Report for Repair/Replacement Activity Ns required by the provisions of the ASME Code Section Xl Work Order Number 98732127-01 I Sheet 2 of 2 9. Remarks (Applicable Manufacturer's Data Reports to be attached)o N-i attached for S/N 44773-1 0 N-i attached for S/N 44773-2 e 0 o + Crorn Sheetr oA 2; This NS-z WQS ori0Hinall1 prepared on o ukilc 6 .lby e ror& S\j iden4ied tWy ASIAE cliss a the 0 SLsevm (ie; 4) QS C lass 3 WIhen i l should have- been 'C lass 1"1 Thi5N's-2 is beiiq regene ¢ e4 corrlc 4 i1e error-Ref% IF>6 O ^ '00 i~CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xi.Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed WSz & Engineer Date 2/912006<J Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,06 , ,7 and employed by HSB CT of ' Hartford, Connecticut have inspected the components described in this Owner's Report during the period lo- R 7-_- to Z-. zs- < , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Commissions H 1Inspector's Signature National Board, State, Province, and Endorsements Date _ _ _ _ A ,(T 2 STEAM GENERATOR PRESERVICE WELD EXAMINATION 's I Modification Package No. Work Package No. Work Order No. Field Weld No. ISI Class Preservice NDE ON 23086 AM1 23080A 98516356 2MS-01 24-68V 2 VT, MT, RT, UT ON 23086 AM1 23080A 98516356 2MS-0124-69V R6 2 VT, MT, RT, UT ON 23086 AM1 23080A 98516356 2MS-0124-71V R4 2 VT, MT, RT, UT ON 23086 AM1 23080A 98516356 2MS-0124-72V Ri 2 VT, MT, RT, UT ON 23086 AM1 23080B 98516357 2MS-0123-68V 2 VT, MT, RT, UT ON 23086 AM1 23080B 98516357 2MS-0123-70V 2 VT, MT, RT, UT ON 23086 AM1 23080B 98516357 2MS-0123-71 V 2 VT, MT, RT, UT ON 23086 AM1 23080B 98516357 2MS-01 23-73V 2 VT. MT. RT. UT ON 23086 AM2 23085A 98516899 2FDW-0226-100V 2 VT, MT, RT, UT ON 23086 AM2 23085A 98516899 2FDW-0226-1 01 V 2 VT, MT, RT, UT ON 23086 AM2 23085A 98516899 2FDW-0226-98V Ri 2 VT, MT, RT, UT ON 23086 AM2 23085A 98516899 2FDW-0226-99V 2 VT, MT, RT, UT ON 23086 AM2 23085B 98516911 2FDW-0253-108V RI 2 VT, MT, RT, UT ON 23086 AM2 23085B 98516911 2FDW-0253-109V Ri 2 VT, MT, RT, UT ON 23086 AM2 23085B 98516911 2FDW-0253-1 1 OV 2 VT, MT, RT, UT f^hI nrt~flP A It Ad 1iii j 1 YI 1 1 ONl' 2308u AM2~e 230850B 985i 69-i i 2FDW-0253-i i i V R2 2 VT, MT, RT, UT ON 23086 AM3 23075A 98530942 2FDW-01 89-30V R3 2 VT, MT, RT, UT ON 23086 AM3 23075A 98530942 2FDW-0210-78V Cl 3 VT, MT 1 of 2 STEAM GENERATOR PRESERVICE WELD EXAMINATION I Modification Package No. Work Package No. Work Order No. Field Weld No. ISI Class Preservice NDE ON 23086 AM3 23075B 98530949 2FDW-0190-49V R2 2 VT, MT, RT, UT ON 23086 AM3 23075B 98530949 2FDW-01 90-50V 2 VT, MT, RT, UT ON 23086 AM4 23065A 98532391 2RC-0279-90V (CL 2A2) 1 VT, MT, RT, UT ON 23086 AM4 23065A 98532391 2RC-0279-91V (CL 2A1) 1 VT, MT, RT, UT ON 23086 AM4 23065B 98532393 2RC-0279-94V (CL 2B2) 1 VT, MT, RT, UT ON 23086 AM4 23065B 98532393 2RC-0279-95V (CL 2B1) 1 VT, MT, RT, UT ON 23086 AM4 23067A 98532391 2RC-0279-88V (HL ME) 1 VT, MT, RT, UT ON 23086 AM4 23067A 98532391 2RC-0279-89V R3a (HL PE) 1 VT, MT, RT, UT ON 23086 AM4 23067B 98532393 2RC-0279-92V (HL) 1 VT, MT, RT, UT ON 23086 AM4 23067B 98532393 2RC-0279-93VR2 (HL) 1 VT, MT, RT, UT ON 23086 AM5 23522A 98532818 2FDW-0280-172V 2 VT, RT ON 23086 AM5 23522A 98532818 2FDW-0281-176V 2 VT, RT ON 23086 AM5 23522A 98532818 2FDW-0282-1 76V 2 VT, RT ON 23086 AM5 23522A 98532818 2FDW-0282-183V 2 VT, RT ON 23086 AM5 23522B 98532820 2FDW-0285-149V 2 VT, RT%-II 23086v AM5l 2322 9532820 2FDW-0286-i 56V 2 Iv 1, R I ON 23086 AM5 23522B 98532820 2FDW-0287-1 63V 2 VT, RT ON 23086 AM5 23522B 98532820 2FDW-0287-1 70V 2 VT, RT 2 of 2 Date: 12/27/05 Sheet: 1 of 1 TO: ONS ISIM Plan Manager FROM: ONS QA Tech. Support PRESERVICE EXAMINATIONS OF CLASS 1 & 2 WELDS RE: As required by ASME Section Y'l 1998 Edition with 2000 addenda. Pre-service examinations were performed on ISI Class 1 & 2 welds made during the U2EOC21 outage timeframe. The following is a list of the welds that received pre-service examinations during this outage timeframe. WORK ORDER WELD NUMBER ISI CLASS INSPECTION TYPE NUMBER MT PT RT UT 98705438 2HP-0483 -1, 2, 3, 2 X_____ ____ ____ 4,5, 12, 13, & 14 _ _ _ _ _ _ _ _2HP-0484 -1, 2, 3, of 8,9,10,11,12, & 2 X 17 2HP-0485 -1,2, 3, 8,9,10,11,12, & 2 X 17 2HP-0486 -1, 2, 3, X 4,5,12,13, & 14 2HP-0487 -1, 2, 3, 4, 5, 6, 7, 8, 9,10, 2 X 11,12,13,14,15, 16,17,18, & 19 2HP-0488 -4, 5, 6, 7,8,9,10, 11,12, 2 x 13,14,15, 16,17, 19, & 20 2LWD-0470 -38, 39, 40, 41, 42, 4:3, 2 X 44, 45, & 46 _98745816 2HP-0497 -55 & 56 2 X 98732127 2HP-0495 -27 1 X_ _ _2HP-0496 -37 1 X I. -4._ _I _- _ _4 Prepared B_ 4_- __;

6.0 Pressure

Testing This is a two-part summary showing a compilation of Class 1 and Class 2 pressure tests conducted from refueling outage EOC-20 through refueling outage EOC-21 for Oconee Unit 2. The first part of this summary, titled "Third Period /Third Interval Summary," is a completion status for the third period of the third 1 0-year interval. The second part, titled"First Period / Fourth Interval Summary," is a completion status for the first period of the fourth 10-year interval.Third Period/ Third Interval Summary Table 6-1 shows the number of the Class 1 pressure tests conducted to fulfill the requirements of the third inspection period of the third 1 0-year interval. There was no through-wall leakage observed during the pressure test.Table 6-1 Outage Specific Summatny Examination Total Examinations Category Test Requirement Credited Since Refueling Outage 20 B-P System Hydrostatic Test (IWB-5222) 2 Table 6-2 shows a completion status of pressure tests conducted during the third period of the third ten-year interval.Table 6-2 Period Specific Summary Total Total (%/o)Examination Test Requirement Examinations Examinations Examinations Category Required For Credited For Complete For_ This Period This Period This Period B-E System Hydrostatic Test 1 1 100%(IWB-5222) B-P System Leakage Test 1 1 100%(IWB-5221) B-P System Hydrostatic Test 7 71 100%(IWB-5222) C-H System 13 13 100%Inservice/Functional Test (IWC-5221) C-H System Hydrostatic Test 43 43 100%(IWC-5222) 1 Two of the seven Category B-P hydrostatic tests required for the third period of the third 1 0-year interval are included in this summary report. The other five were reported previously in the EOC20 summary report. Reference Problem Investigation Process (PIP) serial number 0-03-02056. Refueling Outage Report EOC21 Oconee Unit 2 Section 6 Page 1 of 6 Revision 0 January 10, 2006 The Class 1 (Category B-P) hydrostatic test is required once during each 1 0-year interval. Table 6-3 shows the completion data of the Class 1 (Category B-IP) hydrostatic tests conducted during refueling cycle EOC21. These tests were for the isolated area between two closed valves and were not part of the Class 1 Leakage Test boundary that is required each refueling outage. Therefore, one test was not conducted to satisfy two different interval requirements. Table 6-3 Detailed Class 1 Listing EOC21 Zone Completion Number Boundary Dwg _ Status EOC21 VT-2 Examination Date OZ2H-1 V O-ISIH-1 OOA-2.2 Complete -11/23/05 OZ2H-1W O-ISIH-102A-2.1 I Complete 1 11/23/05 First Period/Fourth Interval Summary m This portion of the summary report is a pressure test completion status for the first period of the fourth ten-year interval. Table 6-4 shows the number of pressure tests completed from refueling outage EOC-20 through refueling outage EOC-21. There was no through-wall leakage observed during these pressure tests.Table 6-4 Outaae Specific Summary Examination Total Examinations Category Test Requirement Credited For This Outage B-P System Leakage Test (IWB-5220) 1 C-H System Leakage Test (IWC-5220) Table 6-5 shows a completion status of pressure tests conducted during 1the first period of the fourth ten-year interval Table 6-5 Period Specific Summary Total Total (%)Examination Test Requirement Examinations Examinations Examinations Category Required For Credited For Complete For This Period This Period This Period B-P System Leakage Test 2 1 50%(IWB-5220) C-H System Leakage Test 52 42 80.77%(IWC-5220) Refueling Outage Report EOC21 Oconee Unit 2 Section 6 Page 2 of 6 Revision 0 Januaiy 10, 2006 The Class 1 (Category B-P) leakage test is required each refueling outage.. Table 6-6 shows the completion data of the Class 1 (Category B-P) leakage test conducted during refueling cycle EOC21.Table 6-6 Detailed Class 1 Listing EOC21 Zone Completion EOC21 VT-2 Code Case(s)Number Boundary Dwg Status Examination Date Used OZ2L-1A O-ISIL4-100A-2.1 Complete 11/23/2005 None O-ISIL4-100A-2.2 Complete 11/23/2005 None O-ISIL4-100A-2.3 Complete 11/23/2005 None O-ISIL4-101 A-2.1 Complete 11/23/2005 None O-ISIL4-101A-2.4 Complete 11/23/2005 None O-ISIL4-102A-2.1 Complete 11/23/2005 None O-ISIL4-102A-2.3 Complete 11/23/2005 None O-ISIL4-11OA-2.1 Complete 11/23/2005 None O-ISIL4-11OA-2.4 Complete 11/23/2005 None OZ2L-1AA O-ISIL4-101A-2.4 Complete 11/23/2005 None OZ2L-1V O-ISIL4-100A-2.2 Complete 11/23/2005 None OZ2L-1Z O-ISIL4-101A-2.4 Complete 11/23/2005 None OZ2L-16 O-ISIL4-101A-2.4 Complete 11/23/2005 None The Class 2 (Category C-H) leakage tests are required each period. Table 6-7 shows the completion data of the Class 2 (Category C-H) leakage tests required for the 1s, Period.Table 6-7 Detailed Class 2 List g ___VT-2 Code Zone Examination Case(s)Number Boundary Dwg Completion Status Date Used 1 IZ2L-10 O-ISIL4-101A-2.3 Completed in EOC21 11/14/05 None 2 IZ2L-11 O-ISIL4-101A-2.3 Completed in EOC21 11/14/05 None 3 IZ2L-12 O-ISIL4-101A-2.3 Not Yet Tested O-ISIL4-101A-2.4 Not Yet Tested 4 IZ2L-13 O-ISIL4-101A-2.3 Completed in EOC21 07/25/05 None 5 IZ2L-14A O-ISIL4-101A-2.3 Completed in EOC21 11/11/05 None 6 IZ2L-14B O-ISIL4-101A-2.3 Compileted in EOC21 11/11/05 None 7 IZ2L-20 O-ISIL4-101A-2.3 Compileted in EOC21 07/27/05 None Refueling Outage Report EOC21 Oconee Unit 2 Section 6 Page 3 of 6 Revision 0 Januaiy 10, 2006 VT-2 Code Zone Examination Case(s)Number Boundary Dwg Completion Status Date Used 8 IZ2L-22 O-ISIL4-101 A-2.3 Not Yet Tested O-ISIL4-102A-2.1 Not Yet Tested O-ISIL4-102A-2.2 Not Yet Tested O-ISIL4-104A-1.2 Not Yet Tested 9 IZ2L-24 O-ISIL4-102A-2.1 Completed in EOC21 08/23/05 None O-ISIL4-103A-2.1 Completed in EOC21 08/23/05 None 10 IZ2L-25 O-ISIL4-102A-2.1 Completed in EOC21 08/25/05 None O-ISIL4-103A-2.1 Completed in EOC21 08/25/05 None 11 IZ2L-27A O-ISIL4-102A-2.1 Not Yet Tested O-ISIL4-102A-2.2 Not Yet Tested 12 IZ2L-27B O-ISIL4-102A-2.2 Completed in EOC21 11/19/05 None 13 IZ2L-4 O-ISIL4-101A-2.1 Completed in EOC21 07/25/05 None 14 IZ2L-41 O-ISIL4-109A-1.1 Not Yet Tested 15 IZ2L-48 O-ISIL4-122A-2.1 Completed in EOC21 06/27/05 None O-ISIL4-122A-2.2 Completed in EOC21 06/27/05 None O-ISIL4-122A-2.3 Completed in EOC21 06/27/05 None O-ISIL4-122B-2.1 Completed in EOC21 06/27/05 None_ O-ISIL4-122A-2.4 Completed in EOC21 06/27/05 None 16 IZ2L-5 O-ISIL4-101 A-2.1 Not Yet Tested O-ISIL4-101A-2.3 Not Yet Tested 17 IZ2L-60 O-ISIL4-124B-2.2 Completed in EOC21 09/06/05 None O-ISIL4-124B-2.4 Completed in EOC21 09/06/05 None 18 OZ2L-14B O-ISIL4-101A-2.4 Completed in EOC21 11/11/05 None 19 OZ2L-15 O-ISIL4-101A-2.4 Completed in EOC21 11/23/05 None 20 OZ2L-16 O-ISIL4-101A-2.4 Completed in EOC21 11/22/05 None 21 OZ2L-17 O-ISIL4-101A-2.2 Completed in EOC21 11/21/05 None 22 OZ2L-17B O-ISIL4-101A-2.2 Completed in EOC21 11/11/05 None 23 OZ2L-18 O-ISIL4-101A-2.2 Completed in EOC21 11/19/05 None Refueling Outage Report EOC21 Oconee Unit 2 Section 6 Page 4 of 6 Revision 0 January 10, 2006 VT-2 Code Zone Examination Case(s)Number Boundary Dwg Completion Status Date Used 24 OZ2L-19A O-ISIL4-104A-1.1 Completed in EOC21 11/14/05 None O-ISIL4-101A-2.5 Completed in EOC21 11/14/05 None 25 OZ2L-19B O-ISIL4-101A-2.5 Completed in EOC21 11/15/05 None 26 OZ2L-1A O-ISIL4-101A-2.1 Completed in EOC21 11/23/05 None O-ISIL4-101A-2.1 Completed in EOC21 11/23/05 None O-ISIL4-101A-2.5 Completed in EOC21 11/23/05 None 27 OZ2L-2 O-ISIL4-101A-2.1 Completed in EOC21 11/23/05 None O-ISIL4-101A-2.4 Completed in EOC21 11/23/05 None O-ISIL4-101A-2.5 Completed in EOC21 11/23/05 None 28 OZ2L-21 O-ISIL4-102A-2.1 Completed in EOC21 11/19/05 None O-ISIL4-102A-2.2 Completed in EOC21 11/19/05 None O-ISIL4-104A-1.2 Completed in EOC21 11/19/05 None 29 OZ2L-23 O-ISIL4-101A-2.2 Completed in EOC21 11/19/05 None O-ISIL4-102A-2.1 Completed in EOC21 11/19/05 None O-ISIL4-102A-2.2 Completed in EOC21 11/19/05 None 30 OZ2L-26 O-ISIL4-102A-2.2 Partial 11/19/05 None 31 OZ2L-28 O-ISIL4-1 02A-2.2 Partial 11/19/05 None 32 OZ2L-29 O-ISIL4-102A-2.2 Completed in EOC21 11/19/05 None 33 OZ2L-29A O-ISIL4-102A-2.2 Completed in EOC21 11/19/05 None_ O-ISIL4-102A-2.3 Completed in EOC21 11/19/05 None 34 OZ2L-3 O-ISIL4-101A-2.1 Completed in EOC21 11/20/05 None 35 OZ2L-30 O-ISIL4-102A-2.2 Completed in EOC21 11/19/05 None 36 OZ2L-30A O-ISIL4-102A-2.2 Completed in EOC21 11/19/05 None O-ISIL4-102A-2.3 Completed in EOC21 11/19/05 None 37 OZ2L-31 A O-ISIL4-102A-2.3 Completed in EOC21 10/22/05 None 38 OZ2L-31B O-ISIL4-102A-2.3 Completed in EOC21 10/22/05 None 39 OZ2L-31 C O-ISIL4-102A-2.3 Completed in EOC21 10/22/05 None 40 OZ2L-39 O-ISIL4-104A-1.1 Not Yet Tested 41 OZ2L-42A O-ISIL4-110A-2.1 Completed in EOC21 11/23/05 None Refueling Outage Report EOC21 Oconee Unit 2 Section 6 Page 5 of 6 Revision 0 January 10, 2006 VT-2 Code Zone Examination Case(s)Number Boundary Dwg Completion Status Date Used 42 OZ2L-42B O-ISIL4-11OA-2.1 Completed in EOC21 11/23/05 None 43 OZ2L-44 O-ISIL4-11OA-2.1 Not Yet Tested O-ISIL4-121 B-2.3 Not Yet Tested O-ISIL4-121 B-2.5 Partial 11/19/05 None O-ISIL4-121 D-1.2 Not Yet Tested O-ISIL4-121 D-2.1 Partial 11/19/05 None O-ISIL4-122A-2.1 Not Yet Tested _44 OZ2L-6 O-ISIL4-101A-2.1 Completed in EOC21 11/19/05 None O-ISIL4-101A-2.2 Completed in EOC21 11/19/05 None O-ISIL4-109A-1.1 Completed in EOC21 11/19/05 None 45 OZ2L-64 O-ISIL4-124B-2.2 Completed in EOC21 11/23/05 None 46 OZ2L-65 O-ISIL4-124B-2.4 Not Yet Tested 47 OZ2L-7 O-ISIL4-101A-2.2 Completed in EOC21 11/11/05 None O-ISIL4-101A-2.3 Completed in EOC21 11/11/05 None 48 OZ2L-7B O-ISIL4-101A-2.3 Completed in EOC21 11/11/05 None O-ISIL4-102A-2.1 Completed in EOC21 11/11/05 None O-ISIL4-102A-2.2 Completed in EOC21 11/11/05 None 49 OZ2L-89 O-ISIL4-116C-2.1 Completed in EOC21 11/04/05 None 50 OZ2L-9 O-ISIL4-101A-2.3 Completed in EOC21 11/19/05 None O-ISIL4-102A-2.1 Completed in EOC21 11/19/05 None O-ISIL4-102A-2.2 Completed in EOC21 11/19/05 None 51 OZ2L-90 O-ISIL4-116C-2.1 Completed in EOC21 11/04/05 None 52 OZ2L-91 O-ISIL4-116C-2.1 Completed in EOC21 11/04/05 None Section 6 Prepared By: Date: J Section 6 Reviewed By: Date: U , / 0 6 Refueling Outage Report EOC21 Oconee Unit 2 Section 6 Page 6 of 6 Revision 0 Janualy 10, 2006}}