Semantic search

Jump to navigation Jump to search
 Issue dateTitleTopic
IR 05000245/198700528 May 1987Insp Rept 50-245/87-05 on 870414-0518.Violations Noted: Potential Generic Deficiency in Processing License Action Requests & Inadequately Restrained Transient Equipment in safety-related Areas W/O Review of Potential ConsequencesHigh Radiation Area
Emergency Lighting
Locked High Radiation Area
Condition Adverse to Quality
Scaffolding
IR 05000245/19870063 April 1987Physical Security Insp Repts 50-245/87-06,50-336/87-07 & 50-423/87-04 on 870223-27.Major Areas Inspected:Security Program Audit,Records & Repts,Security Sys Power Supply, Access control-personnel & Alarm Stations
IR 05000245/198700717 March 1987Insp Rept 50-245/87-07 on 870223-27.No Violations Noted. Major Areas Inspected:Licensee Water Chemistry Control Program,Including Mgt Controls,Plant Water Chemistry Sys, Sampling/Measurement & Implementation of Program
IR 05000245/198700815 April 1987Insp Repts 50-245/87-08,50-336/87-08 & 50-423/87-06 on 870309-13.No Violations Noted.Major Areas Inspected:Licensee Action on Previously Identified Items,Including Solid Radwaste Classification,Handling & TransportationProcess Control Program
IR 05000245/198700922 June 1987Insp Rept 50-245/87-09 on 870420-24.Potential Enforcement Findings Noted:Failure to Make Repts to NRC Per 10CFR50.72 & 50.73,to Take Corrective Action Per 10CFR50,App B,Xvi & to Control Testing Procedures Per 10CFR50,App B,Vi
IR 05000245/198701019 June 1987Insp Repts 50-245/87-10,50-336/87-10 & 50-423/87-11 on 870518-20.No Violations Noted.Major Areas Inspected:Bioassay Whole Body Counting Program,Including Results of Whole Body Counting Phantom Analysis Comparison & Procedures & Data
IR 05000245/198701130 June 1987Insp Rept 50-245/87-11 on 870519-0622.No Violations Noted. Major Areas Inspected:Plant Operations,Surveillance,Maint, Radiation Protection,Physical Security & Fire Protection. Post-outage Spent Fuel Pool Housekeeping Also DiscussedHot Short
High Radiation Area
Stroke time
Met Tower
Emergency Lighting
Excess Flow Check Valve
IR 05000245/198701220 August 1987Insp Rept 50-245/87-12 on 870623-0810.No Violations Noted. Major Areas Inspected:Previously Identified Items,Plant Operations,Surveillance,Maint,Radiation Protection,Physical Security,Fire Protection,Allegations & Outage ActivitiesShutdown Margin
High Radiation Area
Weld Overlay
Emergency Lighting
IR 05000245/19870131 September 1987Insp Repts 50-245/87-13,50-336/87-12 & 50-423/87-13 on 870629-0702.No Violations Noted.Major Areas Inspected: Emergency Preparedness Program
IR 05000245/198701411 August 1987Insp Rept 50-245/87-14 on 870720-24.No Violations Noted. Major Areas Inspected:Licensee Surveillance & Calibr Programs,Surveillance & Calibr Testing,Control of Measuring & Test Equipment & Qa/Qc Involvement
IR 05000245/198701512 August 1987Insp Repts 50-245/87-15,50-336/87-17 & 50-423/87-14 on 870706-10.Violations Noted.Major Areas Inspected:Radiation Protection Activities Associated W/Unit 1 Outage & Status of Station Audit & Hot Particle ProgramsHigh Radiation Area
Scaffolding
IR 05000245/198701618 August 1987Insp Rept 50-245/87-16 on 870706-10.No Violations Noted. Major Areas Inspected:Licensee Action on Previous Insp Findings,Licensee Surveillance of Vendor Inservice Insp (ISI) Activities,Review of ISI Data & IGSCCWeld Overlay
Liquid penetrant
IR 05000245/198701821 September 1987Safety Insp Rept 50-245/87-18 on 870731-0807.No Violations or Deviations Noted.Major Areas Inspected:Test Witnessing, Preliminary Results Evaluation of Containment Integrated Leak Rate Test & Tours of FacilityReactor Vessel Water Level
Scaffolding
IR 05000245/198701915 September 1987Insp Rept 50-245/87-19 on 870817-21.No Violations Noted. Major Areas Inspected:Licensee Effort to Comply W/App R Section Iii.G,J & O Re Fire Protection Features & Maint Safe Shutdown.Two Items Remained UnresolvedSafe Shutdown
Fire Barrier
Emergency Lighting
Exemption Request
IR 05000245/19870202 October 1987Insp Repts 50-245/87-20 & 50-336/87-18 on 870824-28.No Violations or Deviations Noted.Major Areas Inspected: Radioactive Effluents Control Program,Air Cleaning Sys, Radiation Monitoring Sys & Audit ActivitiesOffsite Dose Calculation Manual
IR 05000245/198702121 September 1987Insp Rept 50-245/87-21 on 870811-0909.Violation Noted.Major Areas Inspected:Plant Operations,Surveillance,Maint, Radiation Protection,Physical Security,Fire Protection & Instumentation & Control SurveillanceHigh Radiation Area
Fire Watch
IR 05000245/198702412 November 1987Insp Repts 50-245/87-24,50-336/87-21 & 50-423/87-19 on 870914-17 & 23-24.Major Areas Inspected:Followup of Items Previously Identified Re Capability for post-accident Sampling.Concern Re Technical Review Level Noted
IR 05000245/198702515 October 1987Insp Repts 50-245/87-25 & 50-336/87-19 on 870818-0925.No Violations or Unacceptable Conditions Noted.Major Areas Inspected:Operational Safety,Maint.Periodic & Special Repts, Housekeeping & Unit 1 Control Room Halon TestingPacking leak
High Radiation Area
Fire Barrier
Liquid penetrant
IR 05000245/198702615 October 1987Emergency Preparedness Insp Repts 50-245/87-26,50-336/87-22 & 50-423/87-20 on 871007-09.No Violations Noted.Major Areas Inspected:Observation of 871008 Annual Emergency Excercise. Emergency Response Actions Adequate
IR 05000245/19870278 December 1987Insp Repts 50-245/87-27 & 50-336/87-23 on 870926-1026.No Violation Noted.Major Areas Inspected:Physical Security, Plant Operations,Surveillance & Maint Activities,Fuel Receipt & IE Bulletin 87-00l FollowupSafe Shutdown
Reactor Vessel Water Level
High Radiation Area
Missed surveillance
Unidentified leakage
IR 05000245/198702822 December 1987Insp Repts 50-245/87-28 & 50-336/87-24 on 871102-06.No Violations Noted.Major Areas Inspected:Nonradiological Chemistry Program,Including Measurement Control & Analytical Procedure Evaluations
IR 05000245/19870306 January 1988Insp Repts 50-245/87-30 & 50-336/87-25 on 871027-1130. Violations Noted.Major Areas Inspected:Physical Security, Operations,Svc Water Sys Operability,Vital Dc Switchgear Ventilation,Surveillance & LERsLoop seal
Packing leak
Reserve Station Service Transformer
Unidentified leakage
IR 05000245/198703128 December 1987Insp Repts 50-245/87-31,50-336/87-26 & 50-423/87-27 on 871116-20.No Violations Noted.Major Areas Inspected: Radiation Protection Activities,Including Internal/External Exposure Control & Personnel Selection & TrainingHigh Radiation Area
Locked High Radiation Area
IR 05000245/198703229 January 1988Insp Repts 50-245/87-32,50-336/87-27 & 50-423/87-31 on 871130-1204.No Violations or Deviations Noted.Major Areas Inspected:Surveillance Test Program,In Plant Instrument Calibr,Test Equipment & Cold Weather PreparationHigh winds
Coatings
IR 05000245/198703311 February 1988Insp Repts 50-245/87-33 & 50-336/87-29 on 871201-31. Violations Noted.Major Areas Inspected:Action on Previous Insp Findings,Physical Security,Plant Operations,Lers, Surveillance Testing & Implementation of License AmendsBoric Acid
Design basis earthquake
Scram Discharge Volume
IR 05000245/198800116 February 1988Insp Repts 50-245/88-01,50-336/88-01 & 50-423/88-01 on 880112-15.No Violations Noted.Major Areas Inspected: Radiation Protection Activities Associated W/Unit 2 Outage, Including Internal & External Exposure Controls & Labeling
IR 05000245/19880021 March 1988Insp Rept 50-245/88-02 on 880101-0208.No Violations Noted. Major Areas Inspected:Plant Operations,Physical Security, Second 10-yr Inservice Testing Program,Unplanned Radwaste Discharge,Spent Fuel Pool Overflow & IE Bulletin 87-002High Radiation Area
Exemption Request
Inattentive
IR 05000245/19880037 April 1988Resident Insp Rept 50-245/88-03 on 880209-0321.No Unsafe Plant Conditions Noted.Major Areas Inspected:Physical security,880312 Reactor Scram,Surveillance,Maint,Unlocked High Radiation Area Doors,Lers & Committee ActivitiesHigh Radiation Area
Locked High Radiation Area
IR 05000245/198800427 April 1988Insp Repts 50-245/88-04,50-336/88-08 & 50-423/88-06 on 880328-0401.No Noncompliances Noted.Major Areas Inspected: Plan & Implementing Procedures,Mgt Effectiveness,Program Audit,Records & Repts & Detection AidsSafeguards Contingency Plan
IR 05000245/198800512 May 1987Insp Rept 50-245/88-05 on 880322-0425.No Violations Noted. Major Areas Inspected:Plant Operations,Physical Security, Potential Fouling of ECCS Suction Strainers by Fibrous Insulation,Surveillance,Ler & Committee ActivitiesHigh Radiation Area
Locked High Radiation Area
Missed surveillance
Scram Discharge Volume
IR 05000245/198800624 May 1988Insp Repts 50-245/88-06,50-336/88-09 & 50-423/88-07 on 880411-15.Violations Noted.Major Areas Inspected:Radiation Protection Activities,Including Internal & External Exposure Controls & Station ALARA PracticesHigh Radiation Area
Grab sample
IR 05000245/19880071 July 1988Insp Rept 50-245/88-07 on 880426-0606.No Violations Noted. Major Areas Inspected:Previously Identified Items,Plant Operations,Physical Security Including Strike by Bargaining Unit Security Officers & Potential ECCS Suction Strainer
IR 05000245/19880081 June 1988Physical Security Insp Repts 50-245/88-08,50-336/88-11 & 50-423/88-09 on 880502-03.No Violations Noted.Major Areas Inspected:Licensee Initial Implementation of Strike Plans & Compliance w/NRC-approved Security & Contingency Plans
IR 05000245/198801029 June 1988Insp Repts 50-245/88-10,50-336/88-14 & 50-423/88-11 on 880516-17.No Violations Noted.Major Areas Inspected:Review of Licensee Continued Implementation of Strike Plans & Compliance W/Nrc Approved Security & Contingency Plans
IR 05000245/198801128 July 1988Insp Rept 50-245/88-11 on 880607-0718.No Violations Noted. Major Areas Inspected:Previously Identified Items,Plant Operations,Physical Security,Action Resulting from Emergency Operating Procedures Team Insp & Spent Fuel Pool RerackPacking leak
Downpower
Inattentive
IR 05000245/198801215 September 1988Insp Rept 50-245/88-12 on 880719-0829.No Violations Noted. Major Areas Inspected:Plant Operations,Physical Security, Emergency Operating Procedure Improvement Plan & Various Temporary Instructions
IR 05000245/19880138 September 1988Insp Repts 50-245/88-13,50-336/88-18 & 50-423/88-13 on 880726-29.No Violations Noted.Major Areas Inspected:Unit 2 Radiation Protection Activities,Including Status of Previously Identified Items & Station ALARA PracticesHigh Radiation Area
Locked High Radiation Area
IR 05000245/198801531 October 1988Safety Insp Repts 50-245/88-15,50-336/88-21 & 50-423/88-14 on 880822-25.No Violations,Deviations or Unresolved Items Noted.Major Areas Inspected:Licensee Emergency Preparedness ProgramHealth Physics Network
Siren
IR 05000245/198801718 November 1988Insp Rept 50-245/88-17 on 880830-1017.No Violations Noted. Major Areas Inspected:Previously Identified Items,Plant Operations,Physical Security,Loss of Emergency Svc Water Sys & Loss of Standby Gas Treatment SysPacking leak
High Radiation Area
IR 05000245/198801927 October 1988Insp Repts 50-245/88-19,50-336/88-23 & 50-423/88-17 on 880926-30.No Violations Noted.Major Areas Inspected: Operational Radiological Environ Monitoring Program, Including Mgt Organization & Environ Sample CollectionMet Tower
Annual Radiological Environmental Operating Report
IR 05000245/198900128 February 1989Partially Deleted Insp Repts 50-245/89-01,50-336/89-02 & 50-423/89-01 on 890130-0203 (Ref 10CFR73.21).No Noncompliances Noted.Major Areas Inspected:Security Program Plans & Audits & Detection & Assessment Aids
IR 05000245/198900315 March 1989Insp Repts 50-245/89-03 & 50-336/89-04 on 890213-17.No Violations Noted.Major Areas Inspected:Unit 2 Refueling Outage Activities,Unit 1 Refueling Outage Preparation Activities & Station ALARA Practices
IR 05000245/19890043 May 1989Insp Rept 50-245/89-04 on 8902214-0327.Major Areas Inspected:Previously Identified Items,Plant Operations, Physical Security,Ultrasonic Testing of Condensate Storage Tank,Maint Program Implementation & Committee Activities
IR 05000245/198900517 May 1989Insp Repts 50-245/89-05 & 50-336/89-07 on 890417-21.No Violations Noted.Major Areas Inspected:Engineering Organization & Staffing,Qa,Plant Mods & Technical TrainingProbabilistic Risk Assessment
IR 05000245/19890067 April 1989Insp Repts 50-245/89-06,50-336/89-09 & 50-423/89-06 on 890306-10.No Violations Noted.Major Areas Inspected:Review of Implementation of Radiation Protection Program at Unit 2 During Refueling Outage & Preparation of Outages for Units
IR 05000245/198900723 March 1989Insp Repts 50-245/89-07,50-336/89-06 & 50-423/89-07 on 890221-0303.No Violations or Deviations Noted.Major Areas Inspected:Site Observations & in-ofc Review of Data in Areas of Inservice Insp & Secondary Water Chemistry
IR 05000245/198900815 June 1989Insp Rept 50-245/89-08 on 880328-0508.No Unsafe Plant Conditions Noted.Major Areas Inspected:Plant Operations, Physical Security,Licensee Receipt Insp of New Fuel, Refueling,Plant Mods & LERs
IR 05000245/198900918 May 1989Insp Repts 50-245/89-09 & 50-336/89-10 on 890417-21.No Violations Noted.Major Areas Inspected:Review of Radiation Protection Activites at Unit 2 & Begining of Refueling Outage at Unit 1High Radiation Area
IR 05000245/19890107 June 1989Insp Repts 50-245/89-10 & 50-336/89-12 on 890515-19.No Violations Noted.Major Areas Inspected:Fire Protection & Prevention Program,Including Program Administration & Organization & Administrative Control of CombustiblesSafe Shutdown
Fire Barrier
Exemption Request
Fire Protection Program
IR 05000245/198901219 July 1989Insp Rept 50-245/89-12 on 890509-0615.Major Areas Inspected: Previously Identified Items,Outage Activities,Plant Operations,Physical Security,Recirculation Pump Seal Failure Event,Reactor Scram on Low Main Condenser Vacuum & LERsGrab sample
Weld Overlay
Test box
Missed surveillance
Liquid penetrant