IR 05000254/198501311 May 1985Insp Repts 50-254/85-13,50-265/85-14,50-295/85-19, 50-304/85-20,50-373/85-15,50-374/85-15,50-454/85-20 & 50-455/85-14 on 850425 & 0503.No Violations or Deviations Identified.Areas Inspected:Radiological Environ ProgramOffsite Dose Calculation Manual
IR 05000254/198600313 February 1986Insp Repts 50-454/86-07,50-455/86-06,50-373/86-05, 50-374/86-06,50-254/86-03,50-265/86-03,50-295/86-03 & 50-304/86-03.No Violations or Deviations Noted.Major Areas Inspected:Radiological Environ Monitoring ProgramOffsite Dose Calculation Manual
IR 05000254/199901020 August 1999Insp Repts 50-254/99-10,50-265/99-10,50-454/99-09, 50-455/99-09,50-456/99-10 & 50-457/99-10 on 990628-0721. Major Areas Inspected:Licensee C/A Approach & Implementation of Configuration Control Processes at Each SiteBoric Acid
IR 05000295/19850354 October 1985Mgt Meeting Repts 50-295/85-35,50-304/85-37,50-373/85-31, 50-374/85-32,50-454/85-41 & 50-455/85-29 on 850920.Major Areas Discussed:Items Re Exercise Scheduling for FY86 Exercises
IR 05000318/20070175 August 1985Insp Repts 50-454/85-11 & 50-455/85-08 on 850318-0717. Violations Noted:Failure to Control Special Processes, Resulting in Improper Procedure for Welding Preheat & Weld QualityStolen
IR 05000416/200501523 May 1985Insp Rept 50-455/85-13 on 850416-0515.No Noncompliance or Deviation Noted.Major Areas Inspected:Licensee Action on Previous Insp Findings,Part 21 repts,10CFR50.55(e) Repts & Preoperational Test Procedures
IR 05000424/198505528 April 1986Insp Rept 50-424/85-55 on 850819-860214.Major Areas Inspected:Readiness Review Module 5, Operations Organization & AdministrationEarthquake
IR 05000430/200500217 May 1985Insp Repts 50-454/85-19 & 50-455/85-12 on 850430-0502 & 06-09.Violation Noted:Failure to Provide Adequate Control of Changes to Design Documents
IR 05000445/198903421 June 1989Insp Repts 50-445/89-34 & 50-446/89-34 on 890503-0606.No Significant Strengths,Weaknesses,Violations or Deviations Noted.Major Areas Inspected:Actions on Previous Insp Findings & Followup on Violations/DeviationsFinite Element Analysis
IR 05000454/197800731 August 1978Insp Repts 50-454/78-07 & 50-455/78-07 on 780808-10. Noncompliance Noted:Failure to Prescribe Contractor Personnel Qualification & Certification in Util Approved Instructions or ProceduresHydrostatic
Nondestructive Examination
Liquid penetrant
IR 05000454/19780081 November 1978IE Inspec Repts 50-454/78-08 & 50-455/78-08 on 781004-5 During Which No Items of Noncompliance Were Noted.Major Areas Inspected Incl:Constr Activity,Items from Previous Inspecs
IR 05000454/198200828 June 1982IE Insp Repts 50-454/82-08 & 30-17034/82-01 on 820524-26.No Noncompliance Noted.Major Areas Inspected:Preoperational Radiation Protection Program for Unit 1 & for Byproduct Matl License Authorizing Sources for Storage & Calibr
IR 05000454/198201030 June 1982IE Insp Repts 50-454/82-10 & 50-455/82-07 on 820501-0618. Noncompliance Noted:Failure to Follow Procedures During Preoperational Testing of Emergency Diesel Generators & Safety Injection Sys
IR 05000454/19820112 July 1982IE Insp Repts 50-454/82-11 & 50-455/82-08 on 820602-04.No Noncompliance Noted.Major Areas Inspected:Licensee Followup on IE Bulletins & Circulars,Inspector Identified Problems & Unresolved Items
IR 05000454/198301212 April 1983IE Insp Repts 50-454/83-12 & 50-455/83-10 on 830224,25,28, 0301-04 & 07-09.Noncompliance Noted:Failure to Design Floor Drain Sys to Meet FSAR Commitments & Failure to Conform to Design Requirements in Preoperational Test
IR 05000454/198403514 June 1984IE Safeguards Insp Rept 50-454/84-35 on 840529-0601.No Noncompliance Noted.Major Areas inspected:open-items Re Security Organization Mgt & Access Control Personnel.Details Withheld (Ref 10CFR73.21)
IR 05000454/198408726 March 1987Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $50,000 from Insp Rept 50-454/84-87 on 841231- 850214 & 850315-860724.Violation Noted:Implementation of Major Program Mod W/O Prior NRC Approval
IR 05000454/198500231 May 1985Enforcement Conference Repts 50-454/85-02 & 50-455/85-01 on 850429.Major Areas Discussed:Failure to Maintain Operability of Overtemp & Overpower Delta T ChannelsLoop seal
Breakaway torque
Earthquake
IR 05000454/19850158 July 1985Insp Repts 50-454/85-15 & 50-455/85-10 on 850610-13.No Noncompliance,Deficiencies or Deviations Noted.Major Areas Inspected:Emergency Preparedness ExerciseSafe Shutdown
Hydrostatic
Nuclear Accident Reporting System
IR 05000454/198502117 June 1985Insp Rept 50-454/85-21 on 850502-0603.Noncompliance Noted: Failure to Perform Tech Spec Surveillances When RequiredMissed surveillance
IR 05000454/19850249 July 1985Insp Rept 50-454/85-24 on 850522-0628.No Violations or Deviations Noted.Major Areas Inspected:Licensee Action on Previous Insp Findings & License Conditions & Startup Test Results Evaluation,Verification & WitnessingSafe Shutdown
IR 05000454/19850259 July 1985Insp Rept 50-454/85-25 on 850604-0701.Violation Noted: Failure to Perform Required Tech Spec Surveillances Re RCS Average TempUnanalyzed Condition
Missed surveillance
Hourly Fire Watch
IR 05000454/198502610 July 1985Insp Repts 50-454/85-26 & 50-455/85-18 on 850603,19-20 & 24-25.No Violation or Deviation Noted.Major Areas Inspected: Steam Generator Shell Repairs,Welding of Reactor Vessel Internals & Record Review of safety-related Structures
IR 05000454/198502724 June 1985Insp Repts 50-454/85-27 & 50-455/85-19 on 850605-06.No Violation or Deviation Noted.Major Areas Inspected:Licensee Actions on Previous Insp Findings
IR 05000454/198502826 July 1985Insp Repts 50-454/85-28 & 50-455/85-22 on 850624-28.No Violation or Deviation Noted.Major Areas Inspected:Plant Chemistry & Radiochemistry,Including Mgt Control & Organization & Sampling & Analysis of Water Quality
IR 05000454/19850299 July 1985Insp Repts 50-454/85-29 & 50-455/85-23 on 850619-20.No Violations or Deviations Noted.Major Areas Inspected: 10CFR50.55(e) Repts,Ie Bulletins & Unit 2 Activities Re Installation of Instruments & Associated Fittings
IR 05000454/198503019 August 1985Safety Insp Rept 50-454/85-30 on 850702-0801.Violation Noted:Improper Operation of ECCS & Reactivity Control ComponentFire Watch
IR 05000454/198503313 August 1985Insp Rept 50-454/85-33 on 850709-26.Violation Noted:Failure to Identify Cause for Rod Drops & Communication of Erroneous Info to NRC
IR 05000454/198503510 October 1985Safety Insp Rept 50-454/85-35 on 850805-1002.No Violation or Deviation Noted.Major Areas Inspected:Previous Insp Findings & Startup Test Results Evaluation
IR 05000454/19850369 September 1985Insp Rept 50-454/85-36 on 850802-0903.No Violations or Deviations Noted.Major Areas Inspected:Previous Insp findings,10CFR21 Repts,Lers,Surveillance,Maint,Operational Safety,Startup Testing & Event Followup
IR 05000454/19850377 January 1986Safety Insp Repts 50-454/85-37 & 50-455/85-41 on 850820-21 & 1104-1218.No Violation or Deviation Noted.Major Areas Inspected:Organization & Mgt Controls,Exposure Controls & Control of Radioactive MatlsLoop seal
High Radiation Area
IR 05000454/198503915 October 1985Safety Insp Rept 50-454/85-39 on 850904-1001.Violation Noted:Failure to Perform Tech Spec Surveillances for RCS Water Inventory Balance When Required
IR 05000454/198504016 October 1985Physical Security Insp Rept 50-454/85-40 on 850916-19.No Noncompliance Noted.Major Areas Inspected:Security Organization Performance,Including Security Training,Mgt & Maint Programs.Details Withheld (Ref 10CFR73.21)
IR 05000454/198504322 November 1985Safety Insp Rept 50-454/85-43 on 851002-31.Violation Noted: Failure to Follow Tech Spec Action Requirement to Place Unit in Required Mode When Both Trains of ESF Sys InoperableFire Watch
IR 05000454/198504422 October 1985Insp Repts 50-454/85-44 & 50-455/85-43 on 851003.No Violation or Deviation Noted.Major Areas Inspected:Modified Boeing Steam Generator Snubber Production Tests Conducted by Itt Grinnell
IR 05000454/198504612 November 1985Physical Security Insp Rept 50-454/85-46 on 851025 & 28-30. Noncompliance Noted:Failure to Provide Adequate Access Controls to Two Vital Areas.Details Withheld (Ref 10CFR73.21)
IR 05000454/198504713 December 1985Insp Rept 50-454/85-47 on 851101-1203.Violation Noted: Failure to Perform Tech Spec Surveillance on 125-volt Dc Busses 111 & 112 within Required Time Interval & Failure to Follow Tech Spec Action RequirementMissed surveillance
Fire Watch
IR 05000454/198504816 December 1985Insp Rept 50-454/85-48 on 851028-1107.Violation Noted: Failure to Control motor-operated Valve Setup,Maint & Testing Per Design RequirementsPacking leak
Stroke time
IR 05000454/198504915 January 1986Safety Insp Repts 50-454/85-49 & 50-455/85-34 on 851118-22, 1209-12 & 860110.No Violation Identified.Major Areas Inspected:Closeout of Open Items & Adequacy of Routine Fire Protection Program ImplementationSafe Shutdown
Boric Acid
Fire Barrier
Emergency Lighting
Fire Protection Program
Fire Watch
Scaffolding
IR 05000454/19850506 December 1985Insp Repts 50-454/85-50 & 50-455/85-36 on 851121-22.No Violation or Deviation Noted.Major Areas Inspected:Const Appraisal Team Findings
IR 05000454/19850517 January 1986Insp Repts 50-454/85-51 & 50-455/85-37 on 851125-27.No Violations or Deviations Noted.Major Areas Inspected:Gaseous & Liquid Radioactive Programs,Including Effluent Releases & Effluent Control InstrumentationPacking leak
Grab sample
IR 05000454/198505313 January 1986Insp Rept 50-454/85-53 on 851203-31.Violation Noted:Failure to Follow Approved Procedures Re Protection of Flange Faces of Disassembled ValvesBoric Acid
IR 05000454/198505527 December 1985Insp Repts 50-454/85-55 & 50-455/85-45 on 851202-06. Violation Noted:Failure to Specify Appropriate Acceptance Criteria for Centrifugal,Safety Injection & RHR Pumps
IR 05000454/198505630 December 1985Safety Insp Rept 50-454/85-56 on 851202-13.Violation Noted: Failure to Write Adequate Surveillance/Calibr Procedure. Violation Noted in Insp Rept 50-454/85-42 Re Exceeding Reactor Core Licensed Thermal Power Rating Retracted
IR 05000454/198600130 April 1986App & Errata to SALP Repts 50-454/86-01 & 50-455/86-01 for May 1984 - Oct 1985Systematic Assessment of Licensee Performance
IR 05000454/198600218 February 1986Safety Insp Rept 50-454/86-02 on 860101-31.Violations Noted: Failure to Perform Surveillances within Required Time Interval,Follow Procedures & Effectively Implement Independent Verification ProgramStroke time
Post Accident Monitoring
Temporary Modification
IR 05000454/198600310 February 1986Safety Insp Repts 50-454/86-03 & 50-455/86-03 on 860107-10. No Violations or Deviations Noted.Major Areas Inspected: Program for Instrumentation Cables & Terminations,Including Work Activities,Qa Procedures & Quality Records
IR 05000454/198600411 February 1986Physical Security Insp Rept 50-454/86-04 on 860127-30.No Noncompliance Noted.Major Areas Inspected:Security Organization,Physical Barrier - Vital Areas & Training of Security Personnel.Details Withheld (Ref 10CFR73.21)
IR 05000454/198600520 March 1986Insp Rept 50-454/86-05 on 860201-28.Violation Noted:Failure to Write Appropriate Procedures for Activity Affecting Quality & to Take Timely & Effective Corrective Action for Condition Adverse to Quality & SafetyCondition Adverse to Quality
IR 05000454/198600627 February 1986Insp Repts 50-454/86-06 & 50-455/86-05 on 860204-06.No Violations or Deviations Noted.Major Areas Inspected: Preoperational Gaseous & Liquid Radwaste,Including Status of Certain Preoperational Demonstrations & Tests of SysBoric Acid