ML18354A427

From kanterella
Revision as of 21:12, 5 September 2019 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Superseded by Table Received with Mail 15
ML18354A427
Person / Time
Site: Palisades Entergy icon.png
Issue date: 12/20/2018
From:
Consumers Power Co
To:
Office of Nuclear Reactor Regulation
References
Download: ML18354A427 (1)


Text

Isotope Half Life Fission Products Br-84 Rb-88 Rb-89 Sr-89 Sr-90 Y-90 Sr-91 Y-91 Mo-99 Te-129 I-129 I-131 Te-132 I-132 I-133 Cs-134 Te-134 I-134 I-135 Cs-136 Cs-137 Cs-138 Ba-14o La-14o 32m 18m 15m 54d 28y 64h 9*7h 58d 67h 33d l.7Xl0 7 y 8.0d 77h 2.3h 2lh 2.3y 44m 52m 6.7h 13d 3oy 32m 12.8d 4o.2h Corrosion Products Cr-51 Mn-54 Mn-56 Co-58 Fe-59 Co-60 Zr-95 H-3 27d 300d 2.58h 7ld 45d 5.2y 65d Tritium 12.3y -8 *Less Than 10 Activity (µc/ml) in Waste Receiver Tanks Direct From Primary Coolant System From Chemical & Volume Control Sys After 30-Day Hold After After After As Received 7-Day Hold 30-Day Hold As Received 7-Day Hold 4.66 x 10-2 2.44 6.10 x 10-2 5.33 x 10-3 1.50 x 10-4 5. 77 x 10-4 3.70 x 10-3 2.4o x 10-l 2.26 2.72 x 10-2 5.66 x 10-8 4.40 3.60 x 10-l 1.13 6.38 1.42 2.63 x 10-2 6.4o x 10-l 2.78 1.50 x 10-l 10.6 6.90 x 10-l 6. 78 x 10-3 6.52 x 10-3 2.40 x 10-3 2.00 x 10-5 -2 2.30 x 10 7.90 x 10-3 -6 7.70 x 10 1.10 x 10-3 1.90 x 10-5 * *

  • 4.87 x 10-3 1.50 x 10-4 9.35 x 10-5 2.27 x 10-8 2.21 x 10-l 3,98 x 10-l 2.34 x 10-2 5.66 x 10-8 2.39 7,92 x 10-2 8.10 x 10-2 2.49 x 10-2 1.42 *
  • 8.06 x 10-8 -1 1.03 x 10 10.6 * * *
  • 3.62 x 10-3 1.50 x 10-4 2.42 x 10-7
  • 1.68 x 10-l 1.32 x 10-3 1.45 x 10-2 5.66 x 10-8 3.30 x 10-l 6.60 x 10-4 5,74 x 10-4
  • 1.42 * *
  • 3.03 x 10-2 10.6
  • 4.64 x 10-3 1.34 x 10-3 5.23 x 10-3 1.54 x 10-3 2.00 x 10-3 1.10 x 10-3 2.00 x 10-5 2.00 x 10-5 *
  • 7.4o x 10-3 5.90 x 10-3 6.8o x 10-6 4.90 x 10-6 1.10 x 10-3 '1.10 x 10-3 l.8o x 10-5 l.4o x 10-5 -4 +Less Than 10 4.66 x 10-3 2.44 x 10-l 6.10 x 10-3 -4 5,33 x 10 1.50 x 10-5 -4 5,77 x 10 -4 3,70 x 10 2.4o x 10-l 2.26 2. 72 x 10-3
  • 4.4o x io-1 3.60 x 10-2 1.13 x 10-l 6.38 x 10-l 1.42 2.63 x 10-3 6.4o x 10-2 2.78 x 10-1 1.50 x 10-l 10.6 6.90 x 10-1 6. 78 x 10-4 6.52 x 10-4 2.4o x 10-4 -6 2.00 x 10 2 .30 x 10-3 -4 7,90 x 10 7.70 x 10-7 -4 1.10 x 10 -6 1.90 x 10 * *
  • 4.87 x 10-4 1. 50 x 10-5 9.35 x 10-5
  • 2.21 x 10-1 3 .98 x 10-l 2.34 x 10-3
  • 2.39 x 10-l 7.92 x 10-3 8.10 x 10-3 2. 49 x 10-3 1.42 * * * * *
  • 3 .62 x 10-4 1.50 x 10-5 2.42 x 10-7
  • i.68 x 10-l 1.32 x 10-3 1.45 x 10-3 * -2 3.30 x 10 6.6o x 10-5 5,74 x 10-5
  • 1.42 * *
  • 1.03 x 10-l 3.03 x 10-2 10.6 10.6 *
  • 4.64 x 10-4 1.34 x 10-4 5.23 x 10-4 1.54 x 10-4 2.00 x 10-4 1.10 x 10-4 2.00 x 10-6 2.00 x 10-6
  • 7.4o x 10-4 6.80 x 10-7 1.10 x 10-4 l.8o x 10-6 * -4 5,90 x 10 4.90 x 10-7 ' -4 1.10 x 10 L4o x 10-6 -Unlisted in 10 CFR 20 TABLE 11-3 -ACTIVITY IN COOLANT AND LIQUID WASTE Activity (µc/ml) to Circulating Water Discharge No Radwaste Ion Exchanger No Hold 1.26 x 10-3 6.61 x 10-l 1.65 x 10-2 1.44 x 10-3 4.07 x 10-5 5,77 x 10-4 1.00 x 10-3 2.4o x 10-l 2.26 7,37 x 10-3 1.53 x 10-8 8.36 x 10-l 9.76 x 10-2 3.06 x 10-l 1.73 1.42 7.13 x 10-3 1.73 x 10-l 7,53 x 10-l 1.50 x 10-l 10.6 6.90 x 10-l 1.84 x 10-3 1. 77 x 10-3 6.50 x 10-4 5.4o x 10-6 6.20 x 10-3 2.10 x 10-3 -6 2.10 x 10 -4 3 .00 x 10 5.10 x 10-6 After After 7-Day Hold 30-Day Hold * *
  • 1.32 x 10-3 4.07 x 10-5 9.35 x 10-5
  • 2.21 x 10-l 3 .98 x 10-1 6.35 x 10-3 1.53 x 10-8 4.56 x 10-l 2.15 x 10-2 2.19 x 10-2 6.75 x 10-3 1.42 *
  • 2.18 x 10-8 1.03 x 10-l 10.6
  • 1.26 x 10-3 1.42 x 10-3 * * * -4 9.79 x 10 4.07 x 10-5 2.42 x 10-7
  • 1.68 x 10-1 1.32 x 10-2 3.92 x 10-3 1.53 x 10-8 6.27 x 10-2 1.48 x 10-4 1.55 x 10-5
  • 1.42 * * * -2 3.03 x 10 10.6
  • 3.63 x 10-4 4.18 x 10-4 5.4o x 10-4 3.00 x 10-4 5.4o x 10-6 5.4o x 10-6
  • 2.00 x 10-3 -6 1.90 x 10 3.00 x 10-4 4. 70 x 10-6
  • 1.60 x 10-3 1.30 x 10-6 3.00 x 10-4 3. 70 x 10-6 One Radwaste Ion Exchanger No Hold 1.26 x 10-4 6.61 x 10-2 i.65 x 10-3 1.44 x 10-4 4.07 x 10-6 5. 77 x 10-4 1.00 x 10-4 2.4o x 10-l 2.26 7,37 x 10-4
  • 8.36 x 10-2 9, 76 x 10-3 3.06 x 10-2 1. 73 x 10-l 1.42-x 10-l 7.13 x 10-4 1. 73 x 10-2 7,53 x 10-2 1.50 x 10-2 10.6 6.90 x 10-2 1.84 x 10-4 1. 77 x 10-4 6.50 x 10-5 5.4o x 10-1 6.20 x 10-4 -4 2.10 x 10 2.10 x 10-7 3 .00 x 10-5 5.10 x 10-7 After After 7-Day Hold 30-Day Hold * * * -4 1.32 x 10 4.07 x 10-6 9,35 x 10-5
  • 2.21 x 10-l 3,98 x 10-l 6.35 x 10-4
  • 4.56 x 10-2 2.15 x 10-3 2.19 x 10-3 6.75 x 10-4 1.42 x 10-l * * * * *
  • 9. 79 x 10-5 4.07 x 10-6 2.42 x 10-7
  • 1.68 x 10-l 1.32 x 10-2 3.92 x 10-4
  • 6.27 x 10-3 1.48 x

-6 1.55 x 10 * *

  • 1.03 x 10-2 3.03 x 10-3 10.6 10.6 *
  • 1.26 x 10-4 3.63 x 10-5 1.42 x 10-4 4.18 x 10-5 5.4o x 10-5 3.00 x 10-5 5.4o x 10-7 5.4o x 10-7 * -4 2.00 x 10 1.90 x 10-7 3.00 x 10-5 4. 70 x 10-7
  • 1.60 x 10-4 1.30 x 10-7 3.00 x 10-5 3.7ox10-7 Circulating Water Dilution 2. 5 x 10 5 Two Radwaste Ion Exchangers After After No Hold 7-Day Hold 30-Day Hold 1.26 x 10-5 6.61 x 10-3 1.65 x 10-4 1.44 x 10-5 4.07 x 10-7 5.77x10-4 LOO x 10-5 2.4o x 10-l 2.26 7,37 x 10-5
  • 8.36 x 10-3 9. 76 x 10-4 3.02 x 10-3 1. 73 x 10-2 1.42 x 10-2 7,13 x 10-5 1. 73 x 10-3 7,53 x 10-3 1.50 x 10-3 1.06 x 10-l 6.90 x 10-3 1.84 x 10-5 1. 77 x 10-5 6.50 x 10-6 5.4o x 10-8 6.20 x 10-5 2.10 x 10-5 -8 2.10 x 10 3.00 x 10-6 5.10 x 10-8 * *
  • 1.32 x 10-5 4.07 x 10-7 9,35 x 10-5
  • 2.21 x 10-l 3.98 x 10-l 6.35 x 10-5
  • 4.56 x 10-3 -4 2.15 x 10 2.19 x 10-3 6. 75 x 10-5 1.42 x 10-2 * * * * * * -6 9.79 x 10 4.07 x 10-7 2.42 x 10-7
  • 1.68 x 10-l 1.32 x 10-2 3.92 x 10-5
  • 6.27 x 10-4 1.48 x 10-6 1.55 x 10-7 * * *
  • 1.03 x 10-3 3.03 x 10-4 1.06 x 10-l 1.06 x 10-l *
  • 1.26 x 10-5 3.63 x 10-6 1.42 x 10-5 4.18 x 10-6 5.4o x io-6 3.00 x 10-6 5.4o x 10-8 5.4o x 10-8
  • 2.00 x 10-5 1.90 x 10-8 3.00 x 10-6 4. 70 x 10-8
  • 1.60 x 10-5 1.30 x 10-8 3.00 x 10-6 3.70 x 10-8 Limits 10 CFR 20 µc/ml 3 x 10-6 3 x 10-7 2 x 10-5 7 x 10-5 3 x 10-5 2 x io-4 8 x 10-4 6 x 10-8 3 x 10-7 3 x 10-5 8 x 10-6 1 x 10-6 9 x io-6 2 x 10-5 4 x io-6 9 x 10-5 2 x 10-5 2 x 10-3 1 x 10-4 1 x 10-4 9 x 10-5 5 x 10-5 3 x 10-5 6 x 10-5 No Radwaste Ion Exchanger

.0019 .0005 .0001 + .032 .045 + + 11.10 .013 ,57 25.50 .63 .035 .75 .0067 2.12 .0003 .0004 + + .0003 + + + + .0001 Maximum Fraction of 10 CFR 20 Limit in Circulating Water Discharge No Hold Period 7-Day Hold Period 30-Day Hold Period One Radwaste Two Radwaste No Radwaste One Radwaste Two Radwaste No Radwaste One Radwaste Two Radwaste Ion Exchanger Ion Exchangers Ion Exchanger Ion Exchanger Ion Exchangers Ion Exchanger Ion Exchanger Ion Exchangers

.0002 + ,.0001 + .032 .045 + + 1.11 .0013 .057 2.55 .063 .0035 .075 .0007 .212 + + + + + + + + + .0001 + + .0001 + .032 .045 + 0.111 .0001 .0057 .255 .0063 .0004 .0075 + .0212 +

+ + + + + + + + .0001 .0018 .0005 + + .029 .008 + + 6.08 .0029 .011 .0027 .63 + + .0046 2.12 + + + +

+ + + + + .0001 .0002 + + + .029 .008 + + .608 .0003 .0011 .0003 .063 + + .0005 .212 + + +

+ + + + + + .0001 + + + + .029 .008 + + .0608 + .0001 + .0063 + + + .0212 + + + + + + + +

+ .0001 .0013 .0005 + + .022 .0003 + + .83 +

+ + .63 + + .0013 2.12 +

+ + + + + + + + .0001 .0001 + + + .022 .0003 + + .083 + + + .063 + + .0001 .212 + + + + + + + + + .0001 + + + + .022 .0003 + + .0083 + + + .0063 + + + .0212 + + + + + + + + + .0001