Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 1 of 161 Table 3.5.2-1 Structures and Component Supports - Auxiliary Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Building Framing
- Carbon Steel, Protected (column, hanger, beam, truss, decking, floor grating or plate,
- catwalk, threaded
- fastener, concrete expansion bolt, column base plate, weld, etc.)
HELB Shielding Pipe Whip Restraint Shelter/
Protection Structural Support for Non-Safety Related Structural Support for Regulated Events Structural Support for Safety Related Carbon Steel Plant Indoor Air (Ext)
Loss of Material Boric Acid Corrosion Program III.A3.2-a 3.5.1-20
- 580, 584, H III.B5-7 5-36 A, 580, 584 III.B5.1-b 3.5.1-31 583, A Structural Monitoring Program III.A3.2-a 3.5.1-20 580, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 2 of 161 Table 3.5.2-1 Structures and Component Supports - Auxiliary Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes III.B5.1-a 3.5.1-31 A
Building Framing
- Concrete, Below Grade (wall footing, foundation, slab,
- grout, reinforcement, duct banks, cable pits, tunnels, etc.)
Flood Protection Structural Support for Safety Related Concrete Soil (Ext)
Loss of Material None Required III.A3.1-a 3.5.1-20 571, A III.A3.1-g 3.5.1-21 544, A Change in Material Properties None Required III.A3.1-b 3.5.1-20 557, A III.A3.1-g 3.5.1-21 544, A Cracking None Required III.A3.1-h 3.5.1-25 547, A Cracking and Expansion None Required III.A3.1-c 3.5.1-20 543, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 3 of 161 Table 3.5.2-1 Structures and Component Supports - Auxiliary Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Cracking / Loss of Bond/Matl None Required III.A3.1-e 3.5.1-21 544, A Building Framing
- Concrete, Exposed (foundations, concrete &
masonry wall, beam, roof slab,
- grout, reinforcements, concrete around expansion &
grouted anchors)
Flood Protection Missile Barrier Radiation Shielding Shelter/
Protection Structural Support for Safety Related Concrete Atmosphere/
Weather (Ext)
Change in Material Properties Structural Monitoring Program III.A3.1-b 3.5.1-20 A
III.A3.1-f 3.5.1-20 A
Cracking Structural Monitoring Program III.A3.3-a 3.5.1-24 A
III.A3.1-a 3.5.1-20 A
III.A3.1-h 3.5.1-25 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 4 of 161 Table 3.5.2-1 Structures and Component Supports - Auxiliary Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Cracking and Expansion Structural Monitoring Program III.A3.1-c 3.5.1-20 A
Cracking, Loss of Bond/Material Structural Monitoring Program III.A3.1-d 3.5.1-20 A
Loss of Material Structural Monitoring Program III.A3.1-a 3.5.1-20 A
III.A3.1-f 3.5.1-20 A
Reduction in Concrete Anchor Capacity Structural Monitoring Program III.B5.2-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 5 of 161 Table 3.5.2-1 Structures and Component Supports - Auxiliary Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Building Framing
- Concrete, Protected (foundations, concrete &
masonry wall,
- column, pedestal, beam, floor slab, grout, reinforcements, concrete around expansion &
grouted anchors, cable pits, tunnels, etc.)
Direct Flow Fire Barrier HELB Shielding Missile Barrier Pipe Whip Restraint Radiation Shielding Shelter/
Protection Structural Support for Safety Related Concrete Plant Indoor Air (Ext)
Cracking Structural Monitoring Program III.A3.3-a 3.5.1-24 A
III.A3.1-h 3.5.1-25 A
Cracking and Expansion Structural Monitoring Program III.A3.1-c 3.5.1-20 A
Cracking, Loss of Bond/Material Structural Monitoring Program III.A3.1-d 3.5.1-20 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 6 of 161 Table 3.5.2-1 Structures and Component Supports - Auxiliary Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Loss of Material Structural Monitoring Program III.A3.1-f 3.5.1-20 A
Loss of Strength Structural Monitoring Program III.A3.1-b 3.5.1-20 A
Reduction in Concrete Anchor Capacity Structural Monitoring Program III.B5.2-a 3.5.1-29 A
Flood Barrier -
Carbon Steel, Exposed (water tight doors)
Flood Protection Structural Support for Safety Related Carbon Steel Atmosphere/
Weather (Ext)
Loss of Material Structural Monitoring Program III.A3.2-a 3.5.1-20 580, C Flood Barrier -
Carbon Steel, Protected (water tight doors and gate)
Flood Protection Structural Support for Safety Related Carbon Steel Plant Indoor Air (Ext)
Loss of Leak Tightness Structural Monitoring Program III.A3.2-a 3.5.1-20 531, H N/A N/A N/A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 7 of 161 Table 3.5.2-1 Structures and Component Supports - Auxiliary Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Loss of Material Boric Acid Corrosion Program III.B5.1-b 3.5.1-31 583, C Structural Monitoring Program III.A3.2-a 3.5.1-20 580, C Fuel Related Component -
Carbon Steel, Protected (anchor bolts for SFP gates, liners, transfer tube appurtenances Structural Support for Safety Related Carbon Steel Plant Indoor Air (Ext)
Loss of Material Water Chemistry Program III.A5.2-b 3.5.1-23
- 578, 579, F III.B2-9 5-33 E, 578, 579 Fuel Related Component -
Stainless, Protected (anchor bolts for SFP gates, liners, transfer tube appurtenances Structural Support for Safety Related Stainless Steel Plant Indoor Air (Ext)
Cracking None Required III.A5.2-b 3.5.1-23 535, G N/A N/A N/A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 8 of 161 Table 3.5.2-1 Structures and Component Supports - Auxiliary Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Fuel Related Component -
Stainless, Borated (liner plates, gates, transfer tube expansion bellows)
Expansion /
Separation Fluid Pressure Boundary Structural Support for Safety Related Stainless Steel Treated Water (Ext)
Cracking None Required III.A5.2-b 3.5.1-23 535, E Loss of Material Water Chemistry Program III.A5.2-b 3.5.1-23
- 523, 578, A HELB/MELB Component -
Carbon Steel, Protected (doors, scuttle, blowout panels, floor drains &
screens, guard pipes, louvers, whip restraints, bellows, spray shields, etc.)
Direct Flow Flood Protection HELB Shielding Pipe Whip Restraint Carbon Steel Plant Indoor Air (Ext)
Loss of Leak Tightness Structural Monitoring Program III.A3.2-a 3.5.1-20 532, H N/A N/A N/A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 9 of 161 Table 3.5.2-1 Structures and Component Supports - Auxiliary Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Loss of Material Boric Acid Corrosion Program III.B5.1-b 3.5.1-31 583, C Structural Monitoring Program III.A3.2-a 3.5.1-20 580, C HELB/MELB Component -
- Concrete, Protected (curbs & pipe whip restraint grout, concrete at locations of expansion &
grouted anchors)
Flood Protection HELB Shielding Pipe Whip Restraint Direct Flow Concrete Plant Indoor Air (Ext)
Cracking Structural Monitoring Program III.A3.3-a 3.5.1-24 A
Cracking and Expansion Structural Monitoring Program III.A3.1-c 3.5.1-20 A
Cracking, Loss of Bond/Material Structural Monitoring Program III.A3.1-d 3.5.1-20 A
Loss of Material Structural Monitoring Program III.A3.1-f 3.5.1-20 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 10 of 161 Table 3.5.2-1 Structures and Component Supports - Auxiliary Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Reduction in Conc Anchor Capacity Structural Monitoring Program III.B5.2-a 3.5.1-29 A
HVAC Component -
Stainless, Protected (Control Room vestibule door)
Fluid Pressure Boundary Structural Support for Safety Related Stainless Steel Plant Indoor Air (Ext)
Cracking None Required III.A3.2-a 588, F N/A N/A N/A HVAC Component -
Carbon Steel, Protected (Control Room vestibule door)
Fluid Pressure Boundary Structural Support for Safety Related Carbon Steel Plant Indoor Air (Ext)
Loss of Leak Tightness Structural Monitoring Program III.A3.2-a 3.5.1-20 533, H N/A N/A N/A Loss of Material Boric Acid Corrosion Program III.B5.1-b 3.5.1-31 583, C Structural Monitoring Program III.A3.2-a 3.5.1-20 580, C
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 11 of 161 Table 3.5.2-1 Structures and Component Supports - Auxiliary Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes HVAC Component -
- Concrete, Protected (Control Room vestibules, concrete &
masonry walls, floors, ceilings)
Fluid Pressure Boundary Structural Support for Safety Related Concrete Plant Indoor Air (Ext)
Cracking Structural Monitoring Program III.A3.3-a 3.5.1-24 A
Cracking and Expansion Structural Monitoring Program III.A3.1-c 3.5.1-20 A
Cracking, Loss of Bond/Material Structural Monitoring Program III.A3.1-d 3.5.1-20 A
Loss of Material Structural Monitoring Program III.A3.1-f 3.5.1-20 A
Reduction in Concrete Anchor Capacity Structural Monitoring Program III.B5.2-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 12 of 161 Table 3.5.2-1 Structures and Component Supports - Auxiliary Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes HVAC Component -
Galvanized, Protected (damper &
louver frames)
Fire Barrier Structural Support for Safety Related Galvanized Plant Indoor Air (Ext)
Loss of Material Boric Acid Corrosion Program III.B5.1-b 3.5.1-31
- 581, 583, C Structural Monitoring Program III.A3.2-a 3.5.1-20 581, C Missile Shield -
Carbon Steel, Protected (steel doors and structural steel missile barrier)
Missile Barrier Structural Support for Safety Related Carbon Steel Plant Indoor Air (Ext)
Loss of Material Boric Acid Corrosion Program III.B5.1-b 3.5.1-31 583, C Structural Monitoring Program III.A3.2-a 3.5.1-20 580, C
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 13 of 161 Table 3.5.2-1 Structures and Component Supports - Auxiliary Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Operator Access Component -
Carbon Steel, Protected (stairs, floors, platforms, welds, bolted connections, etc.)
Structural Support for Non-Safety Related Structural Support for Regulated Events Carbon Steel Plant Indoor Air (Ext)
Loss of Material Boric Acid Corrosion Program III.B5.1-b 3.5.1-31 583, A Structural Monitoring Program III.A3.2-a 3.5.1-20 A
Operator Access Component -
- Concrete, Protected (stairs, floors, platforms, concrete at locations of expansion &
grouted anchors, etc.)
Structural Support for Non-Safety Related Structural Support for Regulated Events Concrete Plant Indoor Air (Ext)
Cracking Structural Monitoring Program III.A3.3-a 3.5.1-24 A
III.A3.1-h 3.5.1-25 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 14 of 161 Table 3.5.2-1 Structures and Component Supports - Auxiliary Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Cracking and Expansion Structural Monitoring Program III.A3.1-c 3.5.1-20 A
Cracking, Loss of Bond/Material Structural Monitoring Program III.A3.1-d 3.5.1-20 A
Loss of Material Structural Monitoring Program III.A3.1-f 3.5.1-20 A
Loss of Strength Structural Monitoring Program III.A3.1-b 3.5.1-20 A
Reduction in Concrete Anchor Capacity Structural Monitoring Program III.B5.2-a 3.5.1-29 A
Operator Access Component -
Galvanized, Protected (stairs,
- walkways, removable platform, welds, bolted connections)
Structural Support for Non-Safety Related Structural Support for Regulated Events Galvanized Plant Indoor Air (Ext)
Loss of Material Boric Acid Corrosion Program III.B5.1-b 3.5.1-31
- 581, 583, C
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 15 of 161 Table 3.5.2-1 Structures and Component Supports - Auxiliary Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Structural Monitoring Program III.A3.2-a 3.5.1-20 581, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 16 of 161
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 17 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes ASME 1 Support
- Containment -
Carbon Steel, Protected Structural Support for Safety Related Carbon Steel Containment Air (Ext)
Loss of Material ASME Section XI IWB, IWC, IWD, IWF Inservice Inspection Program III.B1.1.1-a 3.5.1-32 A
Boric Acid Corrosion Program III.B1.1.1-b 3.5.1-31 A
ASME 1 Support
- Containment -
- Concrete, Protected Structural Support for Safety Related Concrete Containment Air (Ext)
Reduction in Conc Anchor Capacity Structural Monitoring Program III.B1.1.4-a 3.5.1-29 A
ASME 1 Support
- Containment -
Sliding Material, Cont Cavity Expansion/
Separation Structural Support for Safety Related Bronze Containment Air (Ext)
Loss of Material None Required III.A4.2-b 3.5.1-20 515, I N/A N/A A, 515, 5004 ASME 1 Support
- Containment -
Sliding Material, Protected Expansion/
Separation Structural Support for Safety Related Bronze Containment Air (Ext)
Loss of Mechanical Function None Required III.B1.1.3-a 3.5.1-32 515, I N/A N/A A, 515, 5004
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 18 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes ASME Class 1 Tubing Support -
Auxiliary Bldg, Carbon Steel, Protected Structural Support for Safety Related Carbon Steel Plant Indoor Air (Ext)
Loss of Material ASME Section XI IWB, IWC, IWD, IWF Inservice Inspection Program III.B1.1.1-a 3.5.1-32 A
Boric Acid Corrosion Program III.B1.1.1-b 3.5.1-31 583, A ASME 2 & 3 Support -
Turbine (Water Treatment Area)
- Carbon Steel, Protected Structural Support for Regulated Events Structural Support for Safety Related Carbon Steel Plant Indoor Air (Ext)
Loss of Material ASME Section XI IWB, IWC, IWD, IWF Inservice Inspection Program III.B1.2.1-a 3.5.1-32 A
ASME 2 & 3 Support -
Turbine (Water Treatment Area)
- Concrete, Protected Structural Support for Regulated Events Structural Support for Safety Related Concrete Plant Indoor Air (Ext)
Reduction in Conc Anchor Capacity Structural Monitoring Program III.B1.2.3-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 19 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes ASME Class 2 &
3 Piping &
Mechanical Component Support -
Auxiliary Bldg, Carbon Steel, Protected Structural Support for Regulated Events Structural Support for Safety Related Carbon Steel Plant Indoor Air (Ext)
Loss of Material ASME Section XI IWB, IWC, IWD, IWF Inservice Inspection Program III.B1.2.1-a 3.5.1-32 A
Boric Acid Corrosion Program III.B1.2.1-b 3.5.1-31 583, A ASME Class 2 &
3 Piping &
Mechanical Component Support -
Auxiliary Bldg, Cast Iron, Protected Structural Support for Safety Related Cast Iron Plant Indoor Air (Ext)
Loss of Material ASME Section XI IWB, IWC, IWD, IWF Inservice Inspection Program III.B1.2.1-a 3.5.1-32 582, F N/A N/A N/A Boric Acid Corrosion Program III.B1.2.1-b 3.5.1-31 582, F N/A N/A N/A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 20 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes ASME Class 2 &
3 Piping &
Mechanical Component Support -
Auxiliary Bldg,
- Concrete, Protected Structural Support for Regulated Events Structural Support for Safety Related Concrete Plant Indoor Air (Ext)
Reduction in Conc Anchor Capacity Structural Monitoring Program III.B1.2.3-a 3.5.1-29 A
3 Piping &
Mechanical Component Support -
Auxiliary Bldg, Galvanized, Protected Structural Support for Regulated Events Structural Support for Safety Related Galvanized Plant Indoor Air (Ext)
Loss of Material ASME Section XI IWB, IWC, IWD, IWF Inservice Inspection Program III.B1.2.1-a 3.5.1-32 581, A Boric Acid Corrosion Program III.B1.2.1-b 3.5.1-31
- 581, 583, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 21 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes ASME Class 2 &
3 Piping &
Mechanical Component Support -
Auxiliary Bldg, Sliding Material, Protected Expansion/
Separation Structural Support for Safety Related Bronze Plant Indoor Air (Ext)
Loss of Mechanical Function None Required III.B1.2.2-a 3.5.1-32 515, I N/A N/A A, 515, 5004 ASME Class 2 &
3 Piping &
Mechanical Component Support -
Containment Bldg, Carbon Steel, Cont Cavity Structural Support for Safety Related Carbon Steel Containment Air (Ext)
Loss of Material ASME Section XI IWB, IWC, IWD, IWF Inservice Inspection Program III.B1.2.1-a 3.5.1-32 A
Boric Acid Corrosion Program III.B1.2.1-b 3.5.1-31 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 22 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes ASME Class 2 &
3 Piping &
Mechanical Component Support -
Containment Bldg, Carbon Steel, Protected Structural Support for Safety Related Carbon Steel Containment Air (Ext)
Loss of Material ASME Section XI IWB, IWC, IWD, IWF Inservice Inspection Program III.B1.2.1-a 3.5.1-32 A
Boric Acid Corrosion Program III.B1.2.1-b 3.5.1-31 A
3 Piping &
Mechanical Component Support -
Containment Bldg, Concrete, Protected Structural Support for Safety Related Concrete Containment Air (Ext)
Reduction in Conc Anchor Capacity Structural Monitoring Program III.B1.2.3-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 23 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes ASME Class 2 &
3 Piping &
Mechanical Component Support -
Containment
- Bldg, Galvanized, Cont Cavity Structural Support for Safety Related Galvanized Containment Air (Ext)
Loss of Material ASME Section XI IWB, IWC, IWD, IWF Inservice Inspection Program III.B1.2.1-a 3.5.1-32 581, A Boric Acid Corrosion Program III.B1.2.1-b 3.5.1-31 581, A ASME Class 2 &
3 Piping &
Mechanical Component Support -
Containment
- Bldg, Galvanized, Protected Structural Support for Safety Related Galvanized Containment Air (Ext)
Loss of Material ASME Section XI IWB, IWC, IWD, IWF Inservice Inspection Program III.B1.2.1-a 3.5.1-32 A
Boric Acid Corrosion Program III.B1.2.1-b 3.5.1-31 581, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 24 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes ASME Class 2 &
3 Piping &
Mechanical Component Support -
Containment Bldg, Sliding
- Material, Protected Expansion/
Separation Structural Support for Safety Related Bronze Containment Air (Ext)
Loss of Mechanical Function None Required III.B1.2.2-a 3.5.1-32 515, I N/A N/A A, 515, 5004 ASME Class 2 &
3 Piping &
Mechanical Component Support -
Containment Bldg, Stainless, Borated Structural Support for Safety Related Stainless Steel Treated Water (Ext)
Loss of Material Water Chemistry Program III.A5.2-b 3.5.1-23
- 567, 587, C ASME Class 2 &
3 Piping &
Mechanical Component Support - Intake Structure Bldg, Carbon Steel, Protected Structural Support for Safety Related Carbon Steel Plant Indoor Air (Ext)
Loss of Material ASME Section XI IWB, IWC, IWD, IWF Inservice Inspection Program III.B1.2.1-a 3.5.1-32 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 25 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes ASME Class 2 &
3 Piping &
Mechanical Component Support - Intake Structure Bldg,
- Concrete, Protected Structural Support for Safety Related Concrete Plant Indoor Air (Ext)
Reduction in Conc Anchor Capacity Structural Monitoring Program III.B1.2.3-a 3.5.1-29 A
3 Piping &
Mechanical Component Support - Intake Structure Bldg, Galvanized, Protected Structural Support for Safety Related Galvanized Plant Indoor Air (Ext)
Loss of Material ASME Section XI IWB, IWC, IWD, IWF Inservice Inspection Program III.B1.2.1-a 3.5.1-32 A
3 Piping &
Mechanical Component Support -
Turbine Bldg, Carbon Steel, Protected Structural Support for Regulated Events Structural Support for Safety Related Carbon Steel Plant Indoor Air (Ext)
Loss of Material ASME Section XI IWB, IWC, IWD, IWF Inservice Inspection Program III.B1.2.1-a 3.5.1-32 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 26 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes ASME Class 2 &
3 Piping &
Mechanical Component Support -
Turbine Bldg,
- Concrete, Protected Structural Support for Regulated Events Structural Support for Safety Related Concrete Plant Indoor Air (Ext)
Reduction in Conc Anchor Capacity Structural Monitoring Program III.B1.2.3-a 3.5.1-29 A
3 Piping &
Mechanical Component Support -
Turbine Bldg, Galvanized, Protected Structural Support for Regulated Events Structural Support for Safety Related Galvanized Plant Indoor Air (Ext)
Loss of Material ASME Section XI IWB, IWC, IWD, IWF Inservice Inspection Program III.B1.2.1-a 3.5.1-32 581, A ASME Class 2 &
3 Piping &
Mechanical Component Support -
Turbine Bldg,
- Sliding, Protected Expansion/
Separation Structural Support for Safety Related Bronze Plant Indoor Air (Ext)
Loss of Mechanical Function None Required III.B1.2.2-a 3.5.1-32 515, I N/A N/A A, 515, 5004
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 27 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes ASME Class 2 &
3 Piping &
Mechanical Component Support - Yard,
Weather (Ext)
Loss of Material Boric Acid Corrosion Program 501, F III.B1.2-4 5-36 A, 501 ASME Class 2 &
3 Piping &
Mechanical Component Support - Yard, Carbon Steel, Below Grade Structural Support for Regulated Events Structural Support for Safety Related Carbon Steel Plant Indoor Air (Ext)
Loss of Material ASME Section XI IWB, IWC, IWD, IWF Inservice Inspection Program III.B1.2.1-a 3.5.1-32 518, A ASME Class 2 &
3 Piping &
Mechanical Component Support - Yard, Carbon Steel, Exposed Structural Support for Regulated Events Structural Support for Safety Related Carbon Steel Atmosphere/
Weather (Ext)
Loss of Material ASME Section XI IWB, IWC, IWD, IWF Inservice Inspection Program III.B1.2.1-a 3.5.1-32 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 28 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes ASME Class 2 &
3 Piping &
Mechanical Component Support - Yard,
- Concrete, Exposed Structural Support for Regulated Events Structural Support for Safety Related Concrete Atmosphere/
Weather (Ext)
Reduction in Conc Anchor Capacity Structural Monitoring Program III.B1.2.3-a 3.5.1-29 A
Elec Component Support -
Auxiliary Bldg, Carbon Steel, Protected Structural Support for Non-Safety Related Structural Support for Regulated Events Structural Support for Safety Related Carbon Steel Plant Indoor Air (Ext)
Loss of Material Boric Acid Corrosion Program III.B2.1-b 3.5.1-31 583, A III.B3.1-b 3.5.1-31 583, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 29 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Structural Monitoring Program III.B2.1-a 3.5.1-29 A
III.B3.1-a 3.5.1-29 A
Elec Component Support -
Auxiliary Bldg, Carbon Steel, Raw Water Structural Support for Non-Safety Related Structural Support for Regulated Events Structural Support for Safety Related Carbon Steel Raw Water (Ext)
Loss of Material Structural Monitoring Program III.B2.1-a 3.5.1-29 594, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 30 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Elec Component Support -
Auxiliary Bldg,
- Concrete, Protected Structural Support for Non-Safety Related Structural Support for Regulated Events Structural Support for Safety Related Concrete Plant Indoor Air (Ext)
Reduction in Conc Anchor Capacity Structural Monitoring Program III.B2.2-a 3.5.1-29 A
III.B3.2-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 31 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Elec Component Support -
Auxiliary Bldg, Concrete, Raw Water Structural Support for Non-Safety Related Structural Support for Regulated Events Structural Support for Safety Related Concrete Raw Water (Ext)
Reduction in Conc Anchor Capacity Structural Monitoring Program III.B2.2-a 3.5.1-29 A
Elec Component Support -
Auxiliary Bldg, Galvanized, Protected Structural Support for Non-Safety Related Structural Support for Regulated Events Structural Support for Safety Related Galvanized Plant Indoor Air (Ext)
Loss of Material Boric Acid Corrosion Program III.B2.1-b 3.5.1-31 581, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 32 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes III.B3.1-b 3.5.1-31 581, A Structural Monitoring Program III.B2.1-a 3.5.1-29 581, A III.B3.1-a 3.5.1-29 581, A Elec Component Support -
Auxiliary Bldg, Galvanized, Raw Water Structural Support for Non-Safety Related Structural Support for Regulated Events Structural Support for Safety Related Galvanized Raw Water (Ext)
Loss of Material Structural Monitoring Program III.B2.1-a 3.5.1-29
- 581, 594, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 33 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Elec Component Support -
Containment Bldg, Carbon
- Steel, Containment Cavity Structural Support for Safety Related Carbon Steel Containment Air (Ext)
Loss of Material Boric Acid Corrosion Program III.B2.1-b 3.5.1-31 A
III.B3.1-b 3.5.1-31 A
Structural Monitoring Program III.B2.1-a 3.5.1-29 A
III.B3.1-a 3.5.1-29 A
Elec Component Support -
Containment Bldg, Carbon Steel, Protected Structural Support for Safety Related Carbon Steel Containment Air (Ext)
Loss of Material Boric Acid Corrosion Program III.B2.1-b 3.5.1-31 A
III.B3.1-b 3.5.1-31 A
Structural Monitoring Program III.B2.1-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 34 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes III.B3.1-a 3.5.1-29 A
Elec Component Support -
Containment Bldg, Concrete, Protected Structural Support for Safety Related Concrete Containment Air (Ext)
Reduction in Conc Anchor Capacity Structural Monitoring Program III.B2.2-a 3.5.1-29 A
III.B3.2-a 3.5.1-29 A
Elec Component Support -
Containment
- Bldg, Galvanized, Containment Cavity Structural Support for Safety Related Galvanized Containment Air (Ext)
Loss of Material Boric Acid Corrosion Program III.B2.1-b 3.5.1-31 581, A III.B3.1-b 3.5.1-31 581, A Structural Monitoring Program III.B2.1-a 3.5.1-29 581, A III.B3.1-a 3.5.1-29 581, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 35 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Elec Component Support -
Containment
- Bldg, Galvanized, Protected Structural Support for Safety Related Galvanized Containment Air (Ext)
Loss of Material Boric Acid Corrosion Program III.B2.1-b 3.5.1-31 581, A III.B3.1-b 3.5.1-31 581, A Structural Monitoring Program III.B2.1-a 3.5.1-29 581, A III.B3.1-a 3.5.1-29 581, A Elec Component Support -
Discharge Structure, Carbon Steel, Protected Structural Support for Non-Safety Related Carbon Steel Plant Indoor Air (Ext)
Loss of Material Structural Monitoring Program III.B2.1-a 3.5.1-29 A
III.B3.1-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 36 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Elec Component Support -
Discharge Structure, Galvanized, Protected Structural Support for Non-Safety Related Galvanized Plant Indoor Air (Ext)
Loss of Material Structural Monitoring Program III.B2.1-a 3.5.1-29 581, A III.B3.1-a 3.5.1-29 581, A Elec Component Support - Intake Structure Bldg, Carbon Steel, Protected Structural Support for Non-Safety Related Structural Support for Regulated Events Structural Support for Safety Related Carbon Steel Plant Indoor Air (Ext)
Loss of Material Structural Monitoring Program III.B2.1-a 3.5.1-29 A
III.B3.1-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 37 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Elec Component Support - Intake Structure Bldg,
- Concrete, Protected Structural Support for Non-Safety Related Structural Support for Regulated Events Structural Support for Safety Related Concrete Plant Indoor Air (Ext)
Reduction in Conc Anchor Capacity Structural Monitoring Program III.B2.2-a 3.5.1-29 A
III.B3.2-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 38 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Elec Component Support - Intake Structure Bldg, Galvanized, Protected Structural Support for Non-Safety Related Structural Support for Regulated Events Structural Support for Safety Related Galvanized Plant Indoor Air (Ext)
Loss of Material Structural Monitoring Program III.B2.1-a 3.5.1-29 581, A III.B3.1-a 3.5.1-29 581, A Elec Component Support - Switch Yard Relay House Group Bldg, Carbon Steel, Protected Structural Support for Regulated Events Carbon Steel Plant Indoor Air (Ext)
Loss of Material Structural Monitoring Program III.B2.1-a 3.5.1-29 A
III.B3.1-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 39 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Elec Component Support - Switch Yard Relay House Group Bldg, Concrete, Protected Structural Support for Regulated Events Concrete Plant Indoor Air (Ext)
Reduction in Conc Anchor Capacity Structural Monitoring Program III.B2.2-a 3.5.1-29 A
III.B3.2-a 3.5.1-29 A
Elec Component Support - Switch Yard Relay House Group
- Bldg, Galvanized, Protected Structural Support for Regulated Events Galvanized Plant Indoor Air (Ext)
Loss of Material Structural Monitoring Program III.B2.1-a 3.5.1-29 581, A III.B3.1-a 3.5.1-29 581, A Elec Component Support -
Turbine Bldg, Carbon Steel, Protected Structural Support for Regulated Events Carbon Steel Plant Indoor Air (Ext)
Loss of Material Structural Monitoring Program III.B2.1-a 3.5.1-29 A
III.B3.1-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 40 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Elec Component Support -
Turbine Bldg,
- Concrete, Protected Structural Support for Regulated Events Concrete Plant Indoor Air (Ext)
Reduction in Conc Anchor Capacity Structural Monitoring Program III.B2.2-a 3.5.1-29 A
III.B3.2-a 3.5.1-29 A
Elec Component Support -
Turbine Bldg, Galvanized, Protected Structural Support for Regulated Events Galvanized Plant Indoor Air (Ext)
Loss of Material Structural Monitoring Program III.B2.1-a 3.5.1-29 581, A III.B3.1-a 3.5.1-29 581, A Elec Component Support - Yard, Carbon Steel, Exposed Structural Support for Regulated Events Carbon Steel Atmosphere/
Weather (Ext)
Loss of Material Structural Monitoring Program III.B2.1-a 3.5.1-29 A
III.B3.1-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 41 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Elec Component Support - Yard,
- Concrete, Exposed Structural Support for Regulated Events Concrete Atmosphere/
Weather (Ext)
Reduction in Conc Anchor Capacity Structural Monitoring Program III.B2.2-a 3.5.1-29 A
III.B3.2-a 3.5.1-29 A
Elec Component Support - Yard, Galvanized, Exposed Structural Support for Regulated Events Galvanized Atmosphere/
Weather (Ext)
Loss of Material Structural Monitoring Program III.B2.1-a 3.5.1-29 581, A III.B3.1-a 3.5.1-29 581, A Elec Component Support - Yard, Galvanized, Raw Water Structural Support for Regulated Events Galvanized Raw Water (Ext)
Loss of Material Structural Monitoring Program III.B3.1-a 3.5.1-29
- 581, 594, A High Strength Bolting -
Containment Building, Carbon Steel, Protected Structural Support for Safety Related Carbon Steel Containment Air (Ext)
Cracking Bolting Integrity Program III.B1.1.2-a 3.5.1-33 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 42 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Loss of Material ASME Section XI IWB, IWC, IWD, IWF Inservice Inspection Program III.B1.1.1-a 3.5.1-32 A
III.B1.2.1-a 3.5.1-32 A
Boric Acid Corrosion Program III.B1.1.1-b 3.5.1-31 A
III.B1.2.1-b 3.5.1-31 A
Non-ASME Component Support -
Auxiliary Bldg,
Loss of Material Boric Acid Corrosion Program VII.A1.1-a 3.3.1-11 503, F III.B2-5 5-36 A, 503
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 43 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Non-ASME Piping &
Mechanical Component Support -
Auxiliary Bldg, Carbon Steel, Protected Structural Support for Non-Safety Related Structural Support for Regulated Events Structural Support for Safety Related Carbon Steel Plant Indoor Air (Ext)
Loss of Material Boric Acid Corrosion Program III.B2.1-b 3.5.1-31 583, A III.B4.1-b 3.5.1-31 583, A Structural Monitoring Program III.B2.1-a 3.5.1-29 A
III.B4.1-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 44 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Non-ASME Piping &
Mechanical Component Support -
Auxiliary Bldg,
- Concrete, Protected Structural Support for Non-Safety Related Structural Support for Regulated Events Structural Support for Safety Related Concrete Plant Indoor Air (Ext)
Reduction in Conc Anchor Capacity Structural Monitoring Program III.B2.2-a 3.5.1-29 A
III.B4.3-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 45 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Non-ASME Piping &
Mechanical Component Support -
Auxiliary Bldg, Galvanized, Protected Structural Support for Non-Safety Related Structural Support for Regulated Events Structural Support for Safety Related Galvanized Plant Indoor Air (Ext)
Loss of Material Boric Acid Corrosion Program III.B2.1-b 3.5.1-31
- 581, 583, A III.B4.1-b 3.5.1-31
- 581, 583, A Structural Monitoring Program III.B2.1-a 3.5.1-29 581, A III.B4.1-a 3.5.1-29 581, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 46 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Non-ASME Piping &
Mechanical Component Support -
Auxiliary Bldg, Stainless, Borated Structural Support for Safety Related Stainless Steel Treated Water (Ext)
Loss of Material Water Chemistry Program III.A5.2-b 3.5.1-23 578, C Non-ASME Piping &
Mechanical Component Support - Boiler Building, Carbon Steel, Protected Structural Support for Non-Safety Related Carbon Steel Plant Indoor Air (Ext)
Loss of Material Structural Monitoring Program III.B2.1-a 3.5.1-29 A
III.B4.1-a 3.5.1-29 A
Non-ASME Piping &
Mechanical Component Support - Boiler
- Building, Concrete, Protected Structural Support for Non-Safety Related Carbon Steel Plant Indoor Air (Ext)
Loss of Material Structural Monitoring Program III.B2.2-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 47 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes III.B4.3-a 3.5.1-29 A
Non-ASME Piping &
Mechanical Component Support -
Containment Bldg, Aluminum, Protected Structural Support for Non-Safety Related Aluminum Containment Air (Ext)
Loss of Material Boric Acid Corrosion Program 502, F III.B2-5 5-36 A, 502 Non-ASME Piping &
Mechanical Component Support -
Containment Bldg, Carbon
- Steel, Containment Cavity Structural Support for Non-Safety Related Structural Support for Safety Related Carbon Steel Containment Air (Ext)
Loss of Material Boric Acid Corrosion Program III.B2.1-b 3.5.1-31 A
III.B4.1-b 3.5.1-31 A
Structural Monitoring Program III.B2.1-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 48 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes III.B4.1-a 3.5.1-29 A
Non-ASME Piping &
Mechanical Component Support -
Containment Bldg, Carbon Steel, Protected Structural Support for Non-Safety Related Structural Support for Safety Related Carbon Steel Containment Air (Ext)
Loss of Material Boric Acid Corrosion Program III.B2.1-b 3.5.1-31 A
III.B4.1-b 3.5.1-31 A
Structural Monitoring Program III.B2.1-a 3.5.1-29 A
III.B4.1-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 49 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Non-ASME Piping &
Mechanical Component Support -
Containment Bldg, Concrete, Protected Structural Support for Non-Safety Related Structural Support for Safety Related Concrete Containment Air (Ext)
Reduction in Conc Anchor Capacity Structural Monitoring Program III.B2.2-a 3.5.1-29 A
III.B4.3-a 3.5.1-29 A
Non-ASME Piping &
Mechanical Component Support -
Containment
- Bldg, Galvanized, Containment Cavity Structural Support for Non-Safety Related Structural Support for Safety Related Galvanized Containment Air (Ext)
Loss of Material Boric Acid Corrosion Program III.B2.1-b 3.5.1-31 581, A III.B4.1-b 3.5.1-31 581, A Structural Monitoring Program III.B2.1-a 3.5.1-29 581, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 50 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes III.B4.1-a 3.5.1-29 581, A Non-ASME Piping &
Mechanical Component Support -
Containment
- Bldg, Galvanized, Protected Structural Support for Non-Safety Related Structural Support for Safety Related Galvanized Containment Air (Ext)
Loss of Material Boric Acid Corrosion Program III.B2.1-b 3.5.1-31 581, A III.B4.1-b 3.5.1-31 581, A Structural Monitoring Program III.B2.1-a 3.5.1-29 581, A III.B4.1-a 3.5.1-29 581, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 51 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Non-ASME Piping &
Mechanical Component Support -
Containment Bldg, Stainless, Borated Structural Support for Non-Safety Related Structural Support for Safety Related Stainless Steel Treated Water (Ext)
Loss of Material Water Chemistry Program III.A5.2-b 3.5.1-23
- 567, 587, C Non-ASME Piping &
Mechanical Component Support -
Discharge Structure, Carbon Steel, Protected Structural Support for Non-Safety Related Carbon Steel Plant Indoor Air (Ext)
Loss of Material Structural Monitoring Program III.B2.1-a 3.5.1-29 A
III.B4.1-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 52 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Non-ASME Piping &
Mechanical Component Support -
Discharge Structure, Cast Iron, Protected Structural Support for Non-Safety Related Cast Iron Plant Indoor Air (Ext)
Loss of Material Structural Monitoring Program III.B2.1-a 3.5.1-29 582, F N/A N/A N/A Non-ASME Piping &
Mechanical Component Support -
Discharge Structure,
- Concrete, Protected Structural Support for Non-Safety Related Concrete Plant Indoor Air (Ext)
Reduction in Conc Anchor Capacity Structural Monitoring Program III.B2.2-a 3.5.1-29 A
III.B4.3-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 53 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Non-ASME Piping &
Mechanical Component Support -
Discharge Structure, Galvanized, Protected Structural Support for Non-Safety Related Galvanized Plant Indoor Air (Ext)
Loss of Material Structural Monitoring Program III.B2.1-a 3.5.1-29 581, A III.B4.1-a 3.5.1-29 581, A Non-ASME Piping &
Mechanical Component Support -
Feedwater Purity Bldg, Carbon Steel, Protected Structural Support for Regulated Events Carbon Steel Plant Indoor Air (Ext)
Loss of Material Structural Monitoring Program III.B2.1-a 3.5.1-29 A
III.B4.1-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 54 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Non-ASME Piping &
Mechanical Component Support -
Feedwater Purity Bldg, Concrete, Protected Structural Support for Regulated Events Concrete Plant Indoor Air (Ext)
Reduction in Conc Anchor Capacity Structural Monitoring Program III.B2.2-a 3.5.1-29 A
III.B4.3-a 3.5.1-29 A
Non-ASME Piping &
Mechanical Component Support - Intake Structure Bldg, Carbon Steel, Protected Structural Support for Non-Safety Related Structural Support for Regulated Events Structural Support for Safety Related Carbon Steel Plant Indoor Air (Ext)
Loss of Material Structural Monitoring Program III.B2.1-a 3.5.1-29 A
III.B4.1-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 55 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Non-ASME Piping &
Mechanical Component Support - Intake Structure Bldg,
- Concrete, Protected Structural Support for Non-Safety Related Structural Support for Regulated Events Structural Support for Safety Related Concrete Plant Indoor Air (Ext)
Reduction in Conc Anchor Capacity Structural Monitoring Program III.B2.2-a 3.5.1-29 A
III.B4.3-a 3.5.1-29 A
Non-ASME Piping &
Mechanical Component Support - Intake Structure Bldg, Galvanized, Protected Structural Support for Non-Safety Related Structural Support for Safety Related Galvanized Plant Indoor Air (Ext)
Loss of Material Structural Monitoring Program III.B2.1-a 3.5.1-29 581, A III.B4.1-a 3.5.1-29 581, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 56 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Non-ASME Piping &
Mechanical Component Support -
Turbine Bldg, Carbon Steel, Protected Structural Support for Non-Safety Related Structural Support for Regulated Events Structural Support for Safety Related Carbon Steel Plant Indoor Air (Ext)
Loss of Material Structural Monitoring Program III.B2.1-a 3.5.1-29 A
III.B4.1-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 57 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Non-ASME Piping &
Mechanical Component Support -
Turbine Bldg,
- Concrete, Protected Structural Support for Non-Safety Related Structural Support for Regulated Events Structural Support for Safety Related Concrete Plant Indoor Air (Ext)
Reduction in Conc Anchor Capacity Structural Monitoring Program III.B2.2-a 3.5.1-29 A
III.B4.3-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 58 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Non-ASME Piping &
Mechanical Component Support -
Turbine Bldg, Galvanized, Protected Structural Support for Non-Safety Related Structural Support for Regulated Events Structural Support for Safety Related Galvanized Plant Indoor Air (Ext)
Loss of Material Structural Monitoring Program III.B2.1-a 3.5.1-29 581, A III.B4.1-a 3.5.1-29 581, A Non-ASME Piping &
Mechanical Component Support - Water Treatment Bldg, Carbon Steel, Protected Structural Support for Non-Safety Related Structural Support for Regulated Events Carbon Steel Plant Indoor Air (Ext)
Loss of Material Structural Monitoring Program III.B2.1-a 3.5.1-29 A
III.B4.1-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 59 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Non-ASME Piping &
Mechanical Component Support - Water Treatment Bldg,
- Concrete, Protected Structural Support for Non-Safety Related Structural Support for Regulated Events Concrete Plant Indoor Air (Ext)
Reduction in Conc Anchor Capacity Structural Monitoring Program III.B2.2-a 3.5.1-29 A
III.B4.3-a 3.5.1-29 A
Non-ASME Piping &
Mechanical Component Support - Yard, Carbon Steel, Exposed Structural Support for Regulated Events Structural Support for Safety Related Carbon Steel Atmosphere/
Weather (Ext)
Loss of Material Structural Monitoring Program III.B2.1-a 3.5.1-29 A
III.B4.1-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 60 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Non-ASME Piping &
Mechanical Component Support - Yard,
- Concrete, Exposed Structural Support for Non-Safety Related Structural Support for Regulated Events Structural Support for Safety Related Concrete Atmosphere/
Weather (Ext)
Reduction in Conc Anchor Capacity Structural Monitoring Program III.B2.2-a 3.5.1-29 A
III.B4.3-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 61 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Non-ASME Piping &
Mechanical Component Support - Yard, Galvanized, Exposed Structural Support for Non-Safety Related Structural Support for Regulated Events Structural Support for Safety Related Galvanized Atmosphere/
Weather (Ext)
Loss of Material Structural Monitoring Program III.B2.1-a 3.5.1-29 581, A III.B4.1-a 3.5.1-29 581, A Spent Fuel Storage Rack -
Auxiliary Building, Boron Carbide, Borated Water Radiation Shielding Boron Carbide Treated Water (Ext)
Loss of Material None Required VII.A2.1-b 3.3.1-10 595, F N/A N/A N/A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 62 of 161 Table 3.5.2-2 Structures and Component Supports - Component Supports - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Spent Fuel Storage Rack -
Auxiliary
- Building, Stainless Steel, Borated Water Structural Support for Safety Related Stainless Steel Treated Water (Ext)
Loss of Material Water Chemistry Program VII.A2.1-c 3.3.1-13 H
III.A5-13 5-25 C
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 63 of 161
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 64 of 161 Table 3.5.2-3 Structures and Component Supports - Containment - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Containment Shell & Base Slab -
Containment Bldg, Carbon Steel, Protected (air locks, equipment hatch, liner
- plate, penetrations)
Heat Sink Pressure Boundary/
Fission Product Retention Structural Support for Safety Related Structural Support for Regulated Events Carbon Steel Containment Air (Ext)
Loss of Leak Tightness Containment Leakage Testing Program II.A3.2-b 3.5.1-05 538, A Loss of Material Boric Acid Corrosion Program II.A1.2-a 3.5.1-12 577, A Containment Inservice Inspection Program II.A1.2-a 3.5.1-12 A
II.A3.1-a 3.5.1-03 A
II.A3.2-a 3.5.1-04 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 65 of 161 Table 3.5.2-3 Structures and Component Supports - Containment - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Containment Leakage Testing Program II.A1.2-a 3.5.1-12 A
II.A3.1-a 3.5.1-03 A
II.A3.2-a 3.5.1-04 A
Containment Shell & Base Slab -
Containment Bldg, Concrete, Below Grade (base mat, foundation, wall, embedded steel, etc.)
Pressure Boundary/
Fission Product Retention Radiation Shielding Structural Support for Safety Related Shelter/
Protection Concrete Soil (Ext)
Change in Material Properties None Required II.A1.1-b 3.5.1-07 572, A II.A1.1-c 3.5.1-07 573, A Cracking None Required II.A1.1-f 3.5.1-08 547, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 66 of 161 Table 3.5.2-3 Structures and Component Supports - Containment - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Cracking and Expansion None Required II.A1.1-d 3.5.1-16 574, A Cracking, Loss of Bond/Matl None Required II.A1.1-e 3.5.1-07 573, A Loss of Material None Required II.A1.1-a 3.5.1-16 575, A None Required II.A1.1-c 3.5.1-07 573, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 67 of 161 Table 3.5.2-3 Structures and Component Supports - Containment - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Containment Shell & Base Slab -
Containment Bldg, Concrete, Exposed (dome, wall, base mat, embedded steel, etc.)
Heat Sink Missile Barrier Pressure Boundary/
Fission Product Retention Radiation Shielding Shelter /
Protection Structural Support for Regulated Events Structural Support for Safety Related Concrete Atmosphere/
Weather (Ext)
Change in Material Properties Containment Inservice Inspection Program II.A1.1-b 3.5.1-07 A
II.A1.1-c 3.5.1-07 A
Cracking Containment Inservice Inspection Program II.A1.1-a 3.5.1-16 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 68 of 161 Table 3.5.2-3 Structures and Component Supports - Containment - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Structural Monitoring Program II.A1.1-f 3.5.1-08 547, A Cracking and Expansion Containment Inservice Inspection Program II.A1.1-d 3.5.1-16 A
Cracking, Loss of Bond/Matl Containment Inservice Inspection Program II.A1.1-e 3.5.1-07 A
Loss of Material Containment Inservice Inspection Program II.A1.1-a 3.5.1-16 A
II.A1.1-c 3.5.1-07 A
Containment Shell & Base Slab -
Containment Bldg, Elastomer, Protected (seals, gaskets, moisture barriers)
Pressure Boundary/
Fission Product Retention Shelter/
Protection Elastomers Containment Air (Ext)
Change in Material Properties Containment Inservice Inspection Program II.A3.3-a 3.5.1-06 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 69 of 161 Table 3.5.2-3 Structures and Component Supports - Containment - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Containment Leakage Testing Program II.A3.3-a 3.5.1-06 A
Cracking Containment Inservice Inspection Program II.A3.3-a 3.5.1-06 A
Containment Leakage Testing Program II.A3.3-a 3.5.1-06 A
Containment Shell & Base Slab -
Containment Bldg, Stainless Steel, Protected (fuel transfer tube and closure flange)
Heat Sink Pressure Boundary/
Fission Product Retention Stainless Steel Containment Air (Ext)
Loss of Material Containment Inservice Inspection Program II.A3.1-a 3.5.1-03 570, A Containment Leakage Testing Program II.A3.1-a 3.5.1-03 570, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 70 of 161 Table 3.5.2-3 Structures and Component Supports - Containment - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Containment Shell Prestressing System -
Containment Bldg, Carbon Steel, Exposed (includes tendons and anchorage components)
Pressure Boundary/
Fission Product Retention Structural Support for Safety Related Carbon Steel Atmosphere/
Weather (Ext)
Loss of Material Containment Inservice Inspection Program II.A1.3-a 3.5.1-15 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 71 of 161
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 72 of 161 Table 3.5.2-4 Structures and Component Supports - Containment Interior Structures - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Building Framing
- Carbon Steel, Protected (column, beam, truss, platform, floor grating or plate, catwalk,
- bracing, threaded
- fastener, concrete expansion bolt, column base plate, welds, etc.)
Heat Sink HELB Shielding Pipe Whip Restraint Structural Support for Regulated Events Structural Support for Safety Related Support for Non-Safety Related Carbon Steel Containment Air (Ext)
Loss of Material Boric Acid Corrosion Program III.A4.2-a 3.5.1-20
- 580, 585, H III.B5-7 5-36 A, 580, 585 III.B5.1-b 3.5.1-29 A
Structural Monitoring Program III.A4.2-a 3.5.1-20 580, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 73 of 161 Table 3.5.2-4 Structures and Component Supports - Containment Interior Structures - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Building Framing
- Concrete, Containment Cavity (reactor shield walls including reinforcements, inserts, grouted anchors)
Heat Sink HELB Shielding Missile Barrier Radiation Shielding Structural Support for Safety Related Concrete Containment Air (Ext)
Cracking and Expansion Structural Monitoring Program III.A4.1-b 3.5.1-20 A
Cracking, Loss of Bond/Material Structural Monitoring Program III.A4.1-d 3.5.1-20 A
Loss of Material Structural Monitoring Program III.A4.1-a 3.5.1-20 A
Change in Material Properties None Required III.A4.1-c 3.5.1-27 576, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 74 of 161 Table 3.5.2-4 Structures and Component Supports - Containment Interior Structures - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Building Framing
- Concrete, Protected (concrete &
masonry wall,
- column, pedestal, beam, slab, grout, reinforcements, concrete around expansion &
grouted anchors, etc.)
Direct Flow Heat Sink HELB Shielding Pipe Whip Restraint Radiation Shielding Structural Support for Regulated Events Structural Support for Non-Safety Related Structural Support for Safety Related Concrete Containment Air (Ext)
Cracking Structural Monitoring Program 559, H Cracking and Expansion Structural Monitoring Program III.A4.1-b 3.5.1-20 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 75 of 161 Table 3.5.2-4 Structures and Component Supports - Containment Interior Structures - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Cracking, Loss of Bond/Material Structural Monitoring Program III.A4.1-d 3.5.1-20 A
Loss of Material Structural Monitoring Program III.A4.1-a 3.5.1-20 A
Reduction in Concrete Anchor Capacity Structural Monitoring Program III.B5.2-a 3.5.1-29 A
Fuel Related Component -
Stainless, Protected (refueling cavity
- liner, containment liner and sump screen, transfer tube)
Structural Support for Safety Related Stainless Steel Containment Air (Ext)
Cracking None Required III.A5.2-b 3.5.1-23 535, E Loss of Material Water Chemistry Program III.A5.2-b 3.5.1-23
- 578, 587, A Structural Monitoring Program III.A5.2-b 3.5.1-23 596, E
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 76 of 161 Table 3.5.2-4 Structures and Component Supports - Containment Interior Structures - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Fuel Related Component -
Carbon Steel, Protected (anchor bolts for refueling cavity liner and transfer tube appurtenances)
Structural Support for Safety Related Carbon Steel Containment Air (Ext)
Loss of Material Water Chemistry Program III.A5.2-b 3.5.1-23
- 578, 579, F III.B2-9 5-33 E, 578, 579 HELB/MELB Component -
Carbon Steel, Protected (steel curbs, pipe whip restraints, spray shields, etc.)
HELB Shielding Pipe Whip Restraint Structural Support for Safety Related Carbon Steel Containment Air (Ext)
Loss of Material Boric Acid Corrosion Program III.B5.1-b 3.5.1-31 C
Structural Monitoring Program III.A4.2-a 3.5.1-20 580, C
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 77 of 161 Table 3.5.2-4 Structures and Component Supports - Containment Interior Structures - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes HELB/MELB Component -
grouted anchors, etc.)
Direct Flow Flood Protection Heat Sink HELB Shielding Pipe Whip Restraint Concrete Containment Air (Ext)
Cracking Structural Monitoring Program H
III.A3-11 5-26 A
Cracking and Expansion Structural Monitoring Program III.A4.1-b 3.5.1-20 A
Cracking, Loss of Bond/Material Structural Monitoring Program III.A4.1-d 3.5.1-20 A
Loss of Material Structural Monitoring Program III.A4.1-a 3.5.1-20 A
Reduction in Conc Anchor Capacity Structural Monitoring Program III.B5.2-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 78 of 161 Table 3.5.2-4 Structures and Component Supports - Containment Interior Structures - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes HVAC Component -
Carbon Steel, Protected (damper &
louver mounting frames)
Structural Support for Safety Related Carbon Steel Containment Air (Ext)
Loss of Material Boric Acid Corrosion Program III.B5.1-b 3.5.1-31 C
Structural Monitoring Program III.A4.2-a 3.5.1-20 580, C HVAC Component -
Galvanized, Protected (damper &
louver mounting frames)
Structural Support for Safety Related Galvanized Containment Air (Ext)
Loss of Material Boric Acid Corrosion Program III.B5.1-b 3.5.1-31 C
Structural Monitoring Program III.A4.2-a 3.5.1-20 580, C
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 79 of 161 Table 3.5.2-4 Structures and Component Supports - Containment Interior Structures - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Missile Shield -
- Concrete, Containment Cavity (removable missile shield above reactor vessel)
Heat Sink Missile Barrier Concrete Containment Air (Ext)
Cracking and Expansion Structural Monitoring Program III.A4.1-b 3.5.1-20 A
Cracking, Loss of Bond/Material Structural Monitoring Program III.A4.1-d 3.5.1-20 A
Loss of Material Structural Monitoring Program III.A4.1-a 3.5.1-20 A
Reduction in Conc Anchor Capacity Structural Monitoring Program III.B5.2-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 80 of 161
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 81 of 161 Table 3.5.2-5 Structures and Component Supports - Discharge Structure - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Building Framing
- Cast Iron, Raw Water (sluice gates)
Structural Support for Non-Safety Related Cast Iron Raw Water (Ext)
Loss of Material Structural Monitoring Program III.A6.2-a 3.5.1-22
- 580, 582, A Building Framing Discharge/Intake Crib - Carbon Steel, Raw Water (sluice gate, column, bracket, beam, bracing, threaded
- fastener, connector, weld, etc.)
Structural Support for Non-Safety Related Carbon Steel Raw Water (Ext)
Loss of Material Structural Monitoring Program III.A6.2-a 3.5.1-22 580, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 82 of 161 Table 3.5.2-5 Structures and Component Supports - Discharge Structure - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Building Framing
- Concrete, Below Grade (wall, footing, foundation, slab,
- grout, reinforcement, trenches, cable pits, tunnels, etc.)
Structural Support for Non-Safety Related Concrete Soil (Ext)
Loss of Material None Required III.A6.1-a 3.5.1-22 571, A III.A6.1-e 3.5.1-22 544, A Change in Material Properties None Required III.A6.1-b 3.5.1-22 557, A III.A6.1-e 3.5.1-22 544, A Cracking and Expansion None Required III.A6.1-c 3.5.1-22 543, A Cracking, Loss of Bond/Matl None Required III.A6.1-d 3.5.1-22 544, A Cracking None Required III.A6.1-f 3.5.1-22 547, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 83 of 161 Table 3.5.2-5 Structures and Component Supports - Discharge Structure - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Building Framing
- Concrete, Exposed (foundations, masonry &
concrete wall, floor/ roof slab,
- grout, reinforcements, steel shapes, concrete around expansion &
grouted anchors)
Structural Support for Non-Safety Related Concrete Atmosphere/
Weather (Ext)
Change in Material Properties Structural Monitoring Program III.A6.1-b 3.5.1-22 A
III.A6.1-e 3.5.1-22 A
Cracking Structural Monitoring Program III.A6.3-a 3.5.1-24 A
III.A6.1-a 3.5.1-22 A
III.A6.1-f 3.5.1-22 A
Cracking and Expansion Structural Monitoring Program III.A6.1-c 3.5.1-22 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 84 of 161 Table 3.5.2-5 Structures and Component Supports - Discharge Structure - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Cracking, Loss of Bond/Material Structural Monitoring Program III.A6.1-d 3.5.1-22 A
Loss of Material Structural Monitoring Program III.A6.1-a 3.5.1-22 A
III.A6.1-e 3.5.1-22 A
Reduction in Concrete Anchor Capacity Structural Monitoring Program III.B5.2-a 3.5.1-29 A
Building Framing
- Concrete, Raw Water (wall, footing, foundation, slab,
- grout, reinforcements)
Structural Support for Non-Safety Related Concrete Raw Water (Ext)
Change in Material Properties Structural Monitoring Program III.A6.1-b 3.5.1-22 557, A III.A6.1-e 3.5.1-22 A
Cracking Structural Monitoring Program III.A6.1-a 3.5.1-22 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 85 of 161 Table 3.5.2-5 Structures and Component Supports - Discharge Structure - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes III.A6.1-f 3.5.1-22 A
Cracking and Expansion Structural Monitoring Program III.A6.1-c 3.5.1-22 A
Loss of Material Structural Monitoring Program III.A6.1-a 3.5.1-22 A
III.A6.1-e 3.5.1-22 A
III.A6.1-h 3.5.1-22 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 86 of 161
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 87 of 161 Table 3.5.2-6 Structures and Component Supports - Feedwater Purity Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Building Framing
- Carbon Steel, Protected (column, beam,
- bracing, threaded
- fastener, concrete expansion bolt, column base plate, welds, etc.)
Structural Support for Regulated Events Carbon Steel Plant Indoor Air (Ext)
Loss of Material Structural Monitoring Program III.A3.2-a 3.5.1-20 580, A Building Framing
- Concrete, Below Grade (pedestal, grade beam, footing, foundation, slab,
- grout, reinforcement, trenches, cable pits, etc.)
Structural Support for Regulated Events Concrete Soil (Ext)
Loss of Material None Required III.A3.1-a 3.5.1-20 571, A III.A3.1-g 3.5.1-21 544, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 88 of 161 Table 3.5.2-6 Structures and Component Supports - Feedwater Purity Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Change in Material Properties None Required III.A3.1-b 3.5.1-20 557, A III.A3.1-g 3.5.1-21 544, A Cracking and Expansion None Required III.A3.1-c 3.5.1-20 543, A Cracking, Loss of Bond/Matl None Required III.A3.1-e 3.5.1-21 544, A Cracking None Required III.A3.1-h 3.5.1-25 547, A Building Framing
- Concrete, Exposed (foundations, masonry/
concrete wall,
- grout, reinforcement, concrete around expansion &
grouted anchors, etc.)
Structural Support for Regulated Events Concrete Atmosphere/
Weather (Ext)
Change in Material Properties Structural Monitoring Program III.A3.1-b 3.5.1-20 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 89 of 161 Table 3.5.2-6 Structures and Component Supports - Feedwater Purity Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes III.A3.1-f 3.5.1-20 A
Cracking Structural Monitoring Program III.A3.3-a 3.5.1-24 A
III.A3.1-a 3.5.1-20 A
III.A3.1-h 3.5.1-25 A
Cracking and Expansion Structural Monitoring Program III.A3.1-c 3.5.1-20 A
Cracking, Loss of Bond/Material Structural Monitoring Program III.A3.1-d 3.5.1-20 A
Loss of Material Structural Monitoring Program III.A3.1-a 3.5.1-20 A
III.A3.1-f 3.5.1-20 A
Reduction in Concrete Anchor Capacity Structural Monitoring Program III.B5.2-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 90 of 161 Table 3.5.2-6 Structures and Component Supports - Feedwater Purity Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Building Framing
- Concrete, Protected (foundations, masonry/
concrete wall,
- column, pedestal, beam, slab, grout, reinforcement, concrete around expansion &
grouted anchors, etc.)
Structural Support for Regulated Events Concrete Plant Indoor Air (Ext)
Cracking Structural Monitoring Program III.A3.3-a 3.5.1-24 A
III.A3.1-h 3.5.1-25 A
Cracking and Expansion Structural Monitoring Program III.A3.1-c 3.5.1-20 A
Cracking, Loss of Bond/Material Structural Monitoring Program III.A3.1-d 3.5.1-20 A
Loss of Material Structural Monitoring Program III.A3.1-f 3.5.1-20 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 91 of 161 Table 3.5.2-6 Structures and Component Supports - Feedwater Purity Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Loss of Strength Structural Monitoring Program III.A3.1-b 3.5.1-20 A
Reduction in Concrete Anchor Capacity Structural Monitoring Program III.B5.2-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 92 of 161
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 93 of 161 Table 3.5.2-7 Structures and Component Supports - Intake Structure - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Building Framing
- Carbon Steel, Raw Water (gates, guides, and trash racks)
Structural Support for Regulated Events Structural Support for Safety Related Carbon Steel Raw Water (Ext)
Loss of Material Structural Monitoring Program III.A6.2-a 3.5.1-22 580, A Building Framing
- Cast Iron, Raw Water (Sluice Gates)
Structural Support for Regulated Events Structural Support for Safety Related Cast Iron Raw Water (Ext)
Loss of Material Structural Monitoring Program III.A6.2-a 3.5.1-22
- 580, 582, A Building Framing
- Galvanized, Raw Water (fasteners and anchor bolts)
Structural Support for Regulated Events Structural Support for Safety Related Galvanized Raw Water (Ext)
Loss of Material Structural Monitoring Program III.A6.2-a 3.5.1-22 581, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 94 of 161 Table 3.5.2-7 Structures and Component Supports - Intake Structure - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Building Framing
- Concrete, Below Grade (wall, foundation, slab, grout, reinforcement, trenches, cable pits, tunnels, etc.)
Shelter /
Protection Structural Support for Regulated Events Structural Support for Safety Related Concrete Soil (Ext)
Loss of Material None Required III.A6.1-a 3.5.1-22 571, A III.A6.1-e 3.5.1-22 544, A Change in Material Properties None Required III.A6.1-b 3.5.1-22 557, A III.A6.1-e 3.5.1-22 544, A Cracking and Expansion None Required III.A6.1-c 3.5.1-22 543, A Cracking, Loss of Bond/Matl None Required III.A6.1-d 3.5.1-22 544, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 95 of 161 Table 3.5.2-7 Structures and Component Supports - Intake Structure - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Cracking None Required III.A6.1-f 3.5.1-22 547, A Building Framing
- Concrete, Exposed (wall, beam, floor slab, roof slab, grout, reinforcements, grouted anchors, etc.)
Fire Barrier Flood Protection Missile Barrier Shelter/
Protection Structural Support for Regulated Events Structural Support for Safety Related Concrete Atmosphere/
Weather (Ext)
Change in Material Properties Structural Monitoring Program III.A6.1-b 3.5.1-22 A
III.A6.1-e 3.5.1-22 A
Cracking Structural Monitoring Program III.A6.3-a 3.5.1-24 A
III.A6.1-a 3.5.1-22 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 96 of 161 Table 3.5.2-7 Structures and Component Supports - Intake Structure - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes III.A6.1-f 3.5.1-22 A
Cracking and Expansion Structural Monitoring Program III.A6.1-c 3.5.1-22 A
Cracking, Loss of Bond/Material Structural Monitoring Program III.A6.1-d 3.5.1-22 A
Loss of Material Structural Monitoring Program III.A6.1-a 3.5.1-22 A
III.A6.1-e 3.5.1-22 A
Reduction in concrete Anchor Capacity Structural Monitoring Program III.B5.2-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 97 of 161 Table 3.5.2-7 Structures and Component Supports - Intake Structure - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Building Framing
- Concrete, Protected (wall, beam, floor slab, grout, reinforcements, grouted anchors, etc.)
Direct Flow Flood Protection Shelter/
Protection Structural Support for Regulated Events Structural Support for Safety Related Concrete Plant Indoor Air (Ext)
Cracking Structural Monitoring Program III.A6.3-a 3.5.1-24 A
III.A6.1-f 3.5.1-22 A
Cracking and Expansion Structural Monitoring Program III.A6.1-c 3.5.1-22 A
Cracking, Loss of Bond/Material Structural Monitoring Program III.A6.1-d 3.5.1-22 A
Loss of Material Structural Monitoring Program III.A6.1-a 3.5.1-22 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 98 of 161 Table 3.5.2-7 Structures and Component Supports - Intake Structure - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes III.A6.1-e 3.5.1-22 A
Loss of Strength Structural Monitoring Program III.A6.1-b 3.5.1-22 A
Reduction in Concrete Anchor Capacity Structural Monitoring Program III.B5.2-a 3.5.1-29 A
Building Framing
- Concrete, Raw Water (wall, column, beam, footing, foundation slab, floor slab, grout, reinforcements, etc.)
Structural Support for Regulated Events Structural Support for Safety Related Concrete Raw Water (Ext)
Change in Material Properties Structural Monitoring Program III.A6.1-b 3.5.1-22 A
III.A6.1-e 3.5.1-22 A
Cracking Structural Monitoring Program III.A6.1-a 3.5.1-22 A
III.A6.1-f 3.5.1-22 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 99 of 161 Table 3.5.2-7 Structures and Component Supports - Intake Structure - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Cracking and Expansion Structural Monitoring Program III.A6.1-c 3.5.1-22 A
Loss of Material Structural Monitoring Program III.A6.1-a 3.5.1-22 A
III.A6.1-e 3.5.1-22 A
III.A6.1-h 3.5.1-22 A
Flood Barrier -
- Concrete, Protected (concrete interior wall in southeast corner)
Flood Protection Concrete Plant Indoor Air (Ext)
Cracking and Expansion Structural Monitoring Program III.A6.1-c 3.5.1-22 A
Cracking, Loss of Bond/Material Structural Monitoring Program III.A6.1-d 3.5.1-22 A
Loss of Material Structural Monitoring Program III.A6.1-e 3.5.1-22 A
Loss of Strength Structural Monitoring Program III.A6.1-b 3.5.1-22 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 100 of 161 Table 3.5.2-7 Structures and Component Supports - Intake Structure - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes HELB/MELB Component -
Carbon Steel, Protected (steel curbs, floor drains, shields, etc.)
Direct Flow Flood Protection Structural Support for Safety Related Carbon Steel Plant Indoor Air (Ext)
Loss of Material Structural Monitoring Program III.A6.2-a 3.5.1-22 580, C HELB/MELB Component -
- Concrete, Protected (concrete /
masonry wall, curbs, etc.)
Direct Flow Flood Protection Concrete Plant Indoor Air (Ext)
Cracking Structural Monitoring Program III.A6.3-a 3.5.1-24 A
Cracking and Expansion Structural Monitoring Program (XI.S6)
III.A6.1-c 3.5.1-22 A
Cracking, Loss of Bond/Material Structural Monitoring Program (XI.S6)
III.A6.1-d 3.5.1-22 A
Loss of Material Structural Monitoring Program (XI.S6)
III.A6.1-e 3.5.1-22 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 101 of 161 Table 3.5.2-7 Structures and Component Supports - Intake Structure - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Reduction in Conc Anchor Capacity Structural Monitoring Program (XI.S6)
III.B5.2-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 102 of 161
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 103 of 161 Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Built-Up Roofing
- Auxiliary Bldg -
Tarred, Exposed Shelter/
Protection Built-up Roofing Atmosphere/
Weather (Ext)
Change in Material Properties Structural Monitoring Program J
N/A N/A A, 5000 Loss of Form Structural Monitoring Program J
N/A N/A A, 5000 Loss of Material Structural Monitoring Program J
N/A N/A A, 5000 Built-Up Roofing
- Discharge Structure -
Tarred, Exposed Structural Support for Non-Safety Related Built-up Roofing Atmosphere/
Weather (Ext)
Change in Material Properties Structural Monitoring Program J
N/A N/A A, 5000 Loss of Form Structural Monitoring Program J
N/A N/A A, 5000 Loss of Material Structural Monitoring Program J
N/A N/A A, 5000 Built-Up Roofing
- Intake Structure Bldg -
Tarred, Exposed Shelter/
Protection Built-up Roofing Atmosphere/
Weather (Ext)
Change in Material Properties Structural Monitoring Program J
N/A N/A A, 5000
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 104 of 161 Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Loss of Form Structural Monitoring Program J
N/A N/A A, 5000 Loss of Material Structural Monitoring Program J
N/A N/A A, 5000 Built-Up Roofing
- Switch Yard Relay House Bldg - Tarred, Exposed Structural Support for Regulated Events Built-up Roofing Atmosphere/
Weather (Ext)
Change in Material Properties Structural Monitoring Program J
N/A N/A A, 5000 Loss of Form Structural Monitoring Program J
N/A N/A A, 5000 Loss of Material Structural Monitoring Program J
N/A N/A A, 5000 Built-Up Roofing
- Water Treatment Bldg -
Tarred, Exposed Structural Support for Non-Safety Related Built-up Roofing Atmosphere/
Weather (Ext)
Change in Material Properties Structural Monitoring Program J
N/A N/A A, 5000 Loss of Form Structural Monitoring Program J
N/A N/A A, 5000
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 105 of 161 Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Loss of Material Structural Monitoring Program J
N/A N/A A, 5000 Crane - Auxiliary Bldg - Carbon Steel, Protected Structural Support for Safety Related Carbon Steel Plant Indoor Air (Ext)
Loss of Material Overhead Load Handling Systems Inspection Program VII.B.1-b 3.3.1-16 B
VII.B.2-a 3.3.1-16 B
Crane -
Containment Bldg - Carbon Steel, Protected Structural Support for Safety Related Carbon Steel Containment Air (Ext)
Loss of Material Overhead Load Handling Systems Inspection Program VII.B.1-b 3.3.1-16 B
VII.B.2-a 3.3.1-16 B
Crane Lift Device -
Containment Bldg - Carbon Steel, Protected Structural Support for Non-Safety Related Carbon Steel Containment Air (Ext)
Loss of Material Overhead Load Handling Systems Inspection Program VII.B.1-b 3.3.1-16 D
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 106 of 161 Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Crane Support -
Auxiliary Bldg -
Carbon Steel, Protected Structural Support for Non-Safety Related Structural Support for Safety Related Carbon Steel Plant Indoor Air (Ext)
Loss of Material Overhead Load Handling Systems Inspection Program VII.B.1-b 3.3.1-16 B
Crane Support -
Containment Bldg - Carbon Steel, Protected Structural Support for Non-Safety Related Structural Support for Safety Related Carbon Steel Containment Air (Ext)
Loss of Material Overhead Load Handling Systems Inspection Program VII.B.1-b 3.3.1-16 B
Auxiliary Bldg -
Carbon Steel, Protected Fire Barrier Carbon Steel Plant Indoor Air (Ext)
Loss of Material Fire Protection Program VII.G.3-d 3.3.1-20 591, B
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 107 of 161 Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Fire Barrier -
Auxiliary Bldg -
- Concrete, Exposed Fire Barrier Concrete Atmosphere/
Weather (Ext)
Change in Material Properties Fire Protection Program VII.G.3-b 3.3.1-30 B
Structural Monitoring Program VII.G.3-b 3.3.1-30 A
Cracking Fire Protection Program VII.G.3-b 3.3.1-30 B
Structural Monitoring Program VII.G.3-b 3.3.1-30 A
Cracking and Expansion Fire Protection Program VII.G.3-b 3.3.1-30 B
Structural Monitoring Program VII.G.3-b 3.3.1-30 A
Cracking, Loss of Bond/Material Fire Protection Program VII.G.3-c 3.3.1-30 B
Structural Monitoring Program VII.G.3-c 3.3.1-30 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 108 of 161 Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Loss of Material Fire Protection Program VII.G.3-b 3.3.1-30 B
Structural Monitoring Program VII.G.3-b 3.3.1-30 A
Auxiliary Bldg -
- Concrete, Protected Fire Barrier Concrete Plant Indoor Air (Ext)
Cracking Fire Protection Program VII.G.3-b 3.3.1-30 B
Structural Monitoring Program VII.G.3-b 3.3.1-30 A
Cracking and Expansion Fire Protection Program VII.G.3-b 3.3.1-30 B
Structural Monitoring Program VII.G.3-b 3.3.1-30 A
Cracking, Loss of Bond/Material Fire Protection Program VII.G.3-c 3.3.1-30 B
Structural Monitoring Program VII.G.3-c 3.3.1-30 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 109 of 161 Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Loss of Material Fire Protection Program VII.G.3-b 3.3.1-30 H
III.A3-9 5-21 E
Structural Monitoring Program VII.G.3-b 3.3.1-30 H
III.A3-9 5-21 E
Auxiliary Bldg -
Fire Stop, Protected Fire Barrier Fire Stops
[Sealant /
Maranite]
Plant Indoor Air (Ext)
Cracking /
Delamination Fire Protection Program VII.G.3-a 3.3.1-20 592, B VII.G.4-a 3.3.1-20 592, B Loss of Material Fire Protection Program VII.G.3-a 3.3.1-20 H
VII.G-1 3-46 B, 5001 VII.G.4-a 3.3.1-20 H
VII.G-1 3-46 B, 5001 Separation Fire Protection Program VII.G.3-a 3.3.1-20 592, B VII.G.4-a 3.3.1-20 592, B Fire Barrier -
Auxiliary Bldg -
Fire Wrap, Protected Fire Barrier Fire Wraps
[Mineral-Wool Batts]
Plant Indoor Air (Ext)
Cracking Fire Protection Program J
N/A N/A B, 5002
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 110 of 161 Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Loss of Material Fire Protection Program J
N/A N/A B, 5002 Fire Barrier -
Containment Bldg - Carbon Steel, Protected Fire Barrier Carbon Steel Plant Indoor Air (Ext)
Loss of Material Fire Protection Program VII.G.5-c 3.3.1-20 B
Containment Bldg - Concrete, Exposed Fire Barrier Concrete Atmosphere/
Weather (Ext)
Change in Material Properties Containment Inservice Inspection Program II.A1.1-b 3.5.1-07 A
II.A1.1-c 3.5.1-07 A
Cracking Containment Inservice Inspection Program II.A1.1-a 3.5.1-16 A
Structural Monitoring Program II.A1.1-f 3.5.1-08 A
Cracking and Expansion Containment Inservice Inspection Program II.A1.1-d 3.5.1-16 A
Cracking, Loss of Bond/Material Containment Inservice Inspection Program II.A1.1-e 3.5.1-07 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 111 of 161 Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Loss of Material Containment Inservice Inspection Program II.A1.1-a 3.5.1-16 A
II.A1.1-c 3.5.1-07 A
Intake Structure Bldg - Carbon Steel, Protected Fire Barrier Carbon Steel Plant Indoor Air (Ext)
Loss of Material Fire Protection Program VII.G.1-d 3.3.1-20 591, B Fire Barrier -
Intake Structure Bldg - Concrete, Exposed Fire Barrier Concrete Atmosphere/
Weather (Ext)
Change in Material Properties Fire Protection Program VII.G.1-b 3.3.1-30 B
Structural Monitoring Program VII.G.1-b 3.3.1-30 A
Cracking Fire Protection Program VII.G.1-b 3.3.1-30 B
Structural Monitoring Program VII.G.1-b 3.3.1-30 A
Cracking and Expansion Fire Protection Program VII.G.1-b 3.3.1-30 B
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 112 of 161 Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Structural Monitoring Program VII.G.1-b 3.3.1-30 A
Cracking, Loss of Bond/Material Fire Protection Program VII.G.1-c 3.3.1-30 B
Structural Monitoring Program VII.G.1-c 3.3.1-30 A
Loss of Material Fire Protection Program VII.G.1-b 3.3.1-30 B
Structural Monitoring Program VII.G.1-b 3.3.1-30 A
Intake Structure Bldg - Fire Stop, Protected Fire Barrier Fire Stops
[Sealant /
Maranite]
Plant Indoor Air (Ext)
Cracking /
Delamination Fire Protection Program VII.G.1-a 3.3.1-20 592, B Loss of Material Fire Protection Program VII.G.1-a 3.3.1-20 H
N/A N/A B, 5001 Separation Fire Protection Program VII.G.1-a 3.3.1-20 592, B
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 113 of 161 Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Fire Barrier -
Intake Structure Bldg - Fire Wrap, Protected Fire Barrier Fire Wraps
[Mineral-Wool Batts]
Plant Indoor Air (Ext)
Cracking Fire Protection Program J
N/A N/A B, 5002 Loss of Material Fire Protection Program J
N/A N/A B, 5002 Fire Barrier -
Turbine Bldg -
Carbon Steel, Protected Fire Barrier Carbon Steel Plant Indoor Air (Ext)
Loss of Material Fire Protection Program VII.G.2-d 3.3.1-20 B
Turbine Bldg -
- Concrete, Exposed Fire Barrier Concrete Atmosphere/
Weather (Ext)
Change in Material Properties Fire Protection Program VII.G.2-b 3.3.1-30 B
Structural Monitoring Program VII.G.2-b 3.3.1-30 A
Cracking Fire Protection Program VII.G.2-b 3.3.1-30 B
Structural Monitoring Program VII.G.2-b 3.3.1-30 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 114 of 161 Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Cracking and Expansion Fire Protection Program VII.G.2-b 3.3.1-30 B
Structural Monitoring Program VII.G.2-b 3.3.1-30 A
Cracking, Loss of Bond/Material Fire Protection Program VII.G.2-c 3.3.1-30 B
Structural Monitoring Program VII.G.2-c 3.3.1-30 A
Loss of Material Fire Protection Program VII.G.2-b 3.3.1-30 B
Structural Monitoring Program VII.G.2-b 3.3.1-30 A
Turbine Bldg -
- Concrete, Protected Fire Barrier Concrete Plant Indoor Air (Ext)
Cracking Fire Protection Program VII.G.2-b 3.3.1-30 B
Structural Monitoring Program VII.G.2-b 3.3.1-30 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 115 of 161 Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Cracking and Expansion Fire Protection Program VII.G.2-b 3.3.1-30 B
Structural Monitoring Program VII.G.2-b 3.3.1-30 A
Cracking, Loss of Bond/Material Fire Protection Program VII.G.2-c 3.3.1-30 B
Structural Monitoring Program VII.G.2-c 3.3.1-30 A
Loss of Material Fire Protection Program VII.G.2-b 3.3.1-30 B
Structural Monitoring Program VII.G.2-b 3.3.1-30 A
Turbine Bldg -
Fire Stop, Protected Fire Barrier Fire Stops
[Sealant /
Maranite]
Plant Indoor Air (Ext)
Cracking /
Delamination Fire Protection Program VII.G.2-a 3.3.1-20 592, B Loss of Material Fire Protection Program VII.G.2-a 3.3.1-20 H
N/A N/A B, 5001 Separation Fire Protection Program VII.G.2-a 3.3.1-20 592, B
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 116 of 161 Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Fire Barrier -
Turbine Bldg -
Fire Wrap, Protected Fire Barrier Fire Wraps
[Mineral-Wool Batts]
Plant Indoor Air (Ext)
Cracking Fire Protection Program J
N/A N/A B, 5002 Loss of Material Fire Protection Program J
N/A N/A B, 5002 Fire Barrier -
Water Treatment Bldg - Concrete, Exposed Fire Barrier Concrete Atmosphere/
Weather (Ext)
Change in Material Properties Fire Protection Program VII.G.2-b 3.3.1-30 B
Structural Monitoring Program VII.G.2-b 3.3.1-30 A
Cracking Fire Protection Program VII.G.2-b 3.3.1-30 B
Structural Monitoring Program VII.G.2-b 3.3.1-30 A
Cracking and Expansion Fire Protection Program VII.G.2-b 3.3.1-30 B
Structural Monitoring Program VII.G.2-b 3.3.1-30 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 117 of 161 Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Cracking, Loss of Bond/Material Fire Protection Program VII.G.2-c 3.3.1-30 B
Structural Monitoring Program VII.G.2-c 3.3.1-30 A
Loss of Material Fire Protection Program VII.G.2-b 3.3.1-30 B
Structural Monitoring Program VII.G.2-b 3.3.1-30 A
Water Treatment Bldg - Concrete, Protected Fire Barrier Concrete Plant Indoor Air (Ext)
Cracking Fire Protection Program VII.G.2-b 3.3.1-30 B
Structural Monitoring Program VII.G.2-b 3.3.1-30 A
Cracking and Expansion Fire Protection Program VII.G.2-b 3.3.1-30 B
Structural Monitoring Program VII.G.2-b 3.3.1-30 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 118 of 161 Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Cracking, Loss of Bond/Material Fire Protection Program VII.G.2-c 3.3.1-30 B
Structural Monitoring Program VII.G.2-c 3.3.1-30 A
Loss of Material Fire Protection Program VII.G.2-b 3.3.1-30 B
Structural Monitoring Program VII.G.2-b 3.3.1-30 A
Water Treatment Bldg - Fire Stop, Protected Fire Barrier Fire Stops
[Sealant /
Maranite]
Plant Indoor Air (Ext)
Cracking /
Delamination Fire Protection Program VII.G.2-a 3.3.1-20 592, B Loss of Material Fire Protection Program VII.G.2-a 3.3.1-20 H
N/A N/A B, 5001 Separation Fire Protection Program VII.G.2-a 3.3.1-20 592, B Fire Barrier -
Water Treatment Bldg - Fire Wrap, Protected Fire Barrier Fire Wraps
[Mineral-Wool Batts]
Plant Indoor Air (Ext)
Cracking Fire Protection Program J
N/A N/A B, 5002
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 119 of 161 Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Loss of Material Fire Protection Program J
N/A N/A B, 5002 Flood Barrier -
Auxiliary Bldg -
Elastomer, Protected Flood Protection Elastomers Plant Indoor Air (Ext)
Change in Material Properties Structural Monitoring Program J
N/A N/A A, 5003 Cracking Structural Monitoring Program J
N/A N/A A, 5003 Flood Barrier -
Turbine Building
- Elastomer, Protected Flood Protection Elastomers Plant Indoor Air (Ext)
Change in Material Properties Structural Monitoring Program J
N/A N/A A, 5003 Cracking Structural Monitoring Program J
N/A N/A A, 5003 HELB/MELB &
EQ Civil/
Structural Component -
Auxiliary Bldg -
Elastomer, Protected Direct Flow Flood Protection Elastomers Plant Indoor Air (Ext)
Change in Material Properties Structural Monitoring Program J
N/A N/A A, 5003
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 120 of 161 Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Cracking Structural Monitoring Program J
N/A N/A A, 5003 HELB/MELB &
EQ Civil/
Structural Component -
Intake Structure Bldg -
Elastomer, Protected Direct Flow Flood Protection Elastomers Plant Indoor Air (Ext)
Change in Material Properties Structural Monitoring Program J
N/A N/A A, 5003 Cracking Structural Monitoring Program J
N/A N/A A, 5003 Mech General Component Support -
Containment Bldg -
Elastomer, Protected Structural Support for Safety Related Elastomers Containment Air (Ext)
Change in Material Properties Structural Monitoring Program J
N/A N/A A, 5003 Cracking Structural Monitoring Program J
N/A N/A A, 5003
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 121 of 161 Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Riprap - Yard -
Soil, Submerged Structural Support for Non-Safety Related Soil Raw Water (Ext)
Loss of Material/Form Structural Monitoring Program III.A6.4-a 3.5.1-22 A
Roof Flashing -
Auxiliary Bldg -
Galvanized, Exposed Shelter/
Protection Galvanized Atmosphere/
Weather (Ext)
Loss of Material Structural Monitoring Program III.A3.2-a 3.5.1-20 A
Roof Flashing -
Intake Structure Bldg -
Galvanized, Exposed Shelter/
Protection Galvanized Atmosphere/
Weather (Ext)
Loss of Material Structural Monitoring Program III.A6.2-a 3.5.1-22 A
Roof Flashing -
Switchyard Relay House -
Galvanized, Exposed Structural Support for Regulated Events Galvanized Atmosphere/
Weather (Ext)
Loss of Material Structural Monitoring Program III.A3.2-a 3.5.1-20 A
Seal, Gasket or Filler - Auxiliary Bldg -
Elastomer, Exposed Shelter/
Protection Elastomers Atmosphere/
Weather (Ext)
Cracking Structural Monitoring Program J
N/A N/A A, 5003
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 122 of 161 Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Seal, Gasket or Filler - Auxiliary Bldg -
Elastomer, Protected Direct Flow Expansion /
Separation Flood Protection Shelter/
Protection Elastomers Plant Indoor Air (Ext)
Change in Material Properties Structural Monitoring Program III.B4.2-a 3.5.1-29 593, A Cracking Structural Monitoring Program III.B4.2-a 3.5.1-29 593, A Seal, Gasket or Filler -
Containment Bldg -
Elastomer, Protected Expansion /
Separation Flood Protection Shelter/
Protection Elastomers Containment Air (Ext)
Change in Material Properties Structural Monitoring Program J
N/A N/A A, 5003 Cracking Structural Monitoring Program J
N/A N/A A, 5003
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 123 of 161 Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Seal, Gasket or Filler - Discharge Structure -
Elastomer, Exposed Structural Support for Non-Safety Related Elastomers Atmosphere/
Weather (Ext)
Change in Material Properties Structural Monitoring Program J
N/A N/A A, 5003 Cracking Structural Monitoring Program J
N/A N/A A, 5003 Seal, Gasket or Filler - Discharge Structure -
Elastomer, Protected Structural Support for Non-Safety Related Elastomers Plant Indoor Air (Ext)
Change in Material Properties Structural Monitoring Program J
N/A N/A A, 5003 Cracking Structural Monitoring Program J
N/A N/A A, 5003 Seal, Gasket or Filler - Intake Structure Bldg -
Elastomer, Exposed Shelter/
Protection Elastomers Atmosphere/
Weather (Ext)
Change in Material Properties Structural Monitoring Program J
N/A N/A A, 5003 Cracking Structural Monitoring Program J
N/A N/A A, 5003
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 124 of 161 Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Seal, Gasket or Filler -
Switchyard Relay House/
Switchgear/
Safeguard Bldg -
Elastomer, Exposed Shelter /
Protection Structural Support for Regulated Events Elastomers Atmosphere/
Weather (Ext)
Change in Material Properties Structural Monitoring Program J
N/A N/A A, 5003 Cracking Structural Monitoring Program J
N/A N/A A, 5003 Seal, Gasket or Filler - Turbine Bldg -
Elastomer, Exposed Structural Support for Non-Safety Related Elastomers Atmosphere/
Weather (Ext)
Change in Material Properties Structural Monitoring Program J
N/A N/A A, 5003 Cracking Structural Monitoring Program J
N/A N/A A, 5003 Seal, Gasket or Filler - Turbine Bldg -
Elastomer, Protected Flood Protection Shelter/
Protection Elastomers Plant Indoor Air (Ext)
Change in Material Properties Structural Monitoring Program J
N/A N/A A, 5003
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 125 of 161 Table 3.5.2-8 Structures and Component Supports - Miscellaneous Structural and Bulk Commodities - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Cracking Structural Monitoring Program J
N/A N/A A, 5003
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 126 of 161
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 127 of 161 Table 3.5.2-9 Structures and Component Supports - Switchyard and Yard Structures - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Building Framing
- Safeguard Bus/Switchgear -
Carbon Steel, Protected (floor beam, panels, welds, threaded fasteners, concrete expansion bolt, etc.)
Structural Support for Regulated Events Carbon Steel Plant Indoor Air (Ext)
Loss of Material Structural Monitoring Program III.A3.2-a 3.5.1-20 580, A Building Framing
- Switchyard -
Concrete, Below Grade (grade beam,
- footing, foundation, slab,
- grout, reinforcement, trenches, cable pits, tunnels, etc.)
Structural Support for Regulated Events Concrete Soil (Ext)
Loss of Material None Required III.A3.1-a 3.5.1-20 571, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 128 of 161 Table 3.5.2-9 Structures and Component Supports - Switchyard and Yard Structures - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes III.A3.1-g 3.5.1-21 544, A Change in Material Properties None Required III.A3.1-b 3.5.1-20 557, A III.A3.1-g 3.5.1-21 544, A Cracking and Expansion None Required III.A3.1-c 3.5.1-20 543, A Cracking, Loss of Bond/Matl None Required III.A3.1-e 3.5.1-21 544, A Cracking None Required III.A3.1-h 3.5.1-25 547, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 129 of 161 Table 3.5.2-9 Structures and Component Supports - Switchyard and Yard Structures - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Building Framing
- Switchyard -
- Concrete, Exposed (masonry/
concrete wall,
- grout, reinforcements, foundations, concrete around expansion &
grouted anchors, bus supports, etc.)
Structural Support for Regulated Events Concrete Atmosphere/
Weather (Ext)
Change in Material Properties Structural Monitoring Program III.A3.1-b 3.5.1-20 A
III.A3.1-f 3.5.1-20 544, A Cracking Structural Monitoring Program III.A3.1-a 3.5.1-20 A
III.A3.3-a 3.5.1-24 A
III.A3.1-h 3.5.1-25 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 130 of 161 Table 3.5.2-9 Structures and Component Supports - Switchyard and Yard Structures - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Cracking and Expansion Structural Monitoring Program III.A3.1-c 3.5.1-20 A
Cracking, Loss of Bond/Matl Structural Monitoring Program III.A3.1-d 3.5.1-20 A
Loss of Material Structural Monitoring Program III.A3.1-a 3.5.1-20 A
III.A3.1-f 3.5.1-20 A
Reduction in Concrete Anchor Capacity Structural Monitoring Program III.B5.2-a 3.5.1-29 A
Building Framing
- Switchyard -
- Concrete, Protected (masonry roof bearing walls, reinforcements, concrete around expansion &
grouted anchors, etc.)
Structural Support for Regulated Events Concrete Plant Indoor Air (Ext)
Cracking Structural Monitoring Program III.A3.1-h 3.5.1-25 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 131 of 161 Table 3.5.2-9 Structures and Component Supports - Switchyard and Yard Structures - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes III.A3.3-a 3.5.1-24 A
Cracking and Expansion Structural Monitoring Program III.A3.1-c 3.5.1-20 A
Cracking, Loss of Bond/Matl Structural Monitoring Program III.A3.1-d 3.5.1-20 A
Loss of Material Structural Monitoring Program III.A3.1-f 3.5.1-20 A
Loss of Strength Structural Monitoring Program III.A3.1-b 3.5.1-20 A
Reduction in Concrete Anchor Capacity Structural Monitoring Program III.B5.2-a 3.5.1-29 A
Metal Roofing &
Siding -
Switchgear &
Safeguard Bus -
Carbon Steel, Exposed (flashing)
Structural Support for Regulated Events Galvanized Atmosphere/
Weather (Ext)
Loss of Material Structural Monitoring Program III.A3.2-a 3.5.1-20 581, C
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 132 of 161 Table 3.5.2-9 Structures and Component Supports - Switchyard and Yard Structures - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Missile Shield -
Yard - Concrete, Exposed (Tank vault roof, pavement over buried piping)
Missile Barrier Concrete Atmosphere/
Weather (Ext)
Change in Material Properties Structural Monitoring Program III.A3.1-b 3.5.1-20 A
III.A3.1-f 3.5.1-20 A
Cracking Structural Monitoring Program III.A3.1-a 3.5.1-20 A
III.A3.1-h 3.5.1-25 A
Cracking and Expansion Structural Monitoring Program III.A3.1-c 3.5.1-20 A
Cracking, Loss of Bond/Matl Structural Monitoring Program III.A3.1-d 3.5.1-20 A
Loss of Material Structural Monitoring Program III.A3.1-a 3.5.1-20 A
Structural Monitoring Program III.A3.1-f 3.5.1-20 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 133 of 161 Table 3.5.2-9 Structures and Component Supports - Switchyard and Yard Structures - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Reduction in Concrete Anchor Capacity Structural Monitoring Program III.B5.2-a 3.5.1-29 A
Tank Foundations -
Building & Yard -
Concrete, Below Grade (concrete foundation)
Structural Support for Regulated Events Structure Functional Support Concrete Soil (Ext)
Loss of Material None Required III.A8.1-a 3.5.1-20 571, A III.A8.1-e 3.5.1-21 544, A Change in Material Properties None Required III.A8.1-b 3.5.1-20 557, A III.A8.1-e 3.5.1-21 544, A Cracking and Expansion None Required III.A8.1-c 3.5.1-20 543, A Cracking, Loss of Bond/Matl None Required III.A8.1-d 3.5.1-21 544, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 134 of 161 Table 3.5.2-9 Structures and Component Supports - Switchyard and Yard Structures - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Cracking None Required III.A8.1-f 3.5.1-25 547, A Tank Foundations -
Building & Yard -
- Concrete, Exposed (concrete foundation)
Structural Support for Regulated Events Structural Support for Safety Related Concrete Atmosphere /
Weather Cracking Structural Monitoring Program III.A8.1-a 3.5.1-20 A
Loss of Material Structural Monitoring Program III.A8.1-a 3.5.1-20 A
Change in Material Properties Structural Monitoring Program III.A8.1-b 3.5.1-20 A
Cracking and Expansion Structural Monitoring Program III.A8.1-c 3.5.1-20 A
Cracking, Loss of Bond/Matl Structural Monitoring Program III.A8.1-d 3.5.1-21 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 135 of 161
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 136 of 161 Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Building Framing
- Boiler Buildings Area - Carbon Steel, Protected (column, hanger, beam, truss,
- decking, platform, floor grating or plate,
- catwalk, threaded
- fastener, concrete expansion bolt, column base plate, welds, etc.)
Structural Support for Non-Safety Related Carbon Steel Plant Indoor air (Ext)
Loss of Material Structural Monitoring Program III.A3.2-a 3.5.1-20 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 137 of 161 Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Building Framing
- Boiler Buildings Area - Concrete, Below Grade (wall, pedestal, grade beam,
- footing, foundation, slab,
- grout, reinforcement, cable pits, tunnels, etc.)
Structural Support for Non-Safety Related Concrete Soil (Ext)
Loss of Material None Required III.A3.1-a 3.5.1-20 571, A III.A3.1-g 3.5.1-21 544, A Change in Material Properties None Required III.A3.1-b 3.5.1-20 557, A III.A3.1-g 3.5.1-21 544, A Cracking and Expansion None Required III.A3.1-c 3.5.1-20 543, A Cracking, Loss of Bond/Matl None Required III.A3.1-e 3.5.1-21 544, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 138 of 161 Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Cracking None Required III.A3.1-h 3.5.1-25 547, A Building Framing
- Boiler Buildings Area - Concrete, Exposed (foundations, masonry/
concrete wall,
- grout, reinforcements, concrete around expansion &
grouted anchors, etc.)
Structural Support for Non-Safety Related Concrete Atmosphere /
Weather (Ext)
Cracking Structural Monitoring Program III.A3.1-a 3.5.1-20 A
III.A3.1-h 3.5.1-25 A
III.A3.3-a 3.5.1-24 A
Loss of Material Structural Monitoring Program III.A3.1-a 3.5.1-20 A
III.A3.1-f 3.5.1-20 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 139 of 161 Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Change in Material Properties Structural Monitoring Program III.A3.1-b 3.5.1-20 A
III.A3.1-f 3.5.1-20 A
Cracking and Expansion Structural Monitoring Program III.A3.1-c 3.5.1-20 A
Cracking, Loss of Bond/Matl Structural Monitoring Program III.A3.1-d 3.5.1-20 A
Reduction in Concrete Anchor Capacity Structural Monitoring Program III.B5.2-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 140 of 161 Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Building Framing
- Boiler Buildings Area - Concrete, Protected (foundations, concrete &
masonry wall, column, beam, floor/roof slab,
- grout, reinforcements, concrete around expansion &
grouted anchors, etc.)
Structural Support for Non-Safety Related Concrete Plant Indoor Air (Ext)
Loss of Strength Structural Monitoring Program III.A3.1-b 3.5.1-20 A
Cracking and Expansion Structural Monitoring Program III.A3.1-c 3.5.1-20 A
Cracking, Loss of Bond/Matl Structural Monitoring Program III.A3.1-d 3.5.1-20 A
Loss of Material Structural Monitoring Program III.A3.1-f 3.5.1-20 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 141 of 161 Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Cracking Structural Monitoring Program III.A3.1-h 3.5.1-25 A
III.A3.3-a 3.5.1-24 A
Reduction in Concrete Anchor Capacity Structural Monitoring Program III.B5.2-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 142 of 161 Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Building Framing
- Carbon Steel, Protected (column, beam, truss, decking, platform, floor grating or plate, catwalk, bracing, threaded
- fastener, concrete expansion bolt, column base plate, welds, etc.)
Flood Protection HELB Shielding Pipe Whip Restraint Shelter/
Protection Structural Support for Non-Safety Related Structural Support for Regulated Events Structural Support for Safety Related Carbon Steel Plant Indoor Air (Ext)
Loss of Material Structural Monitoring Program III.A3.2-a 3.5.1-20 580, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 143 of 161 Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Building Framing
- Concrete, Below Grade (wall, pedestal, grade beam,
- footing, foundation, slab,
- grout, reinforcement, cable pits, tunnels, etc.)
Structural Support for Non-Safety Related Structural Support for Regulated Events Structural Support for Safety Related Concrete Soil (Ext)
Loss of Material None Required III.A3.1-a 3.5.1-20 571, A III.A3.1-g 3.5.1-21 544, A Change in Material Properties None Required III.A3.1-b 3.5.1-20 557, A III.A3.1-g 3.5.1-21 544, A Cracking and Expansion None Required III.A3.1-c 3.5.1-20 543, A Cracking, Loss of Bond/Matl None Required III.A3.1-e 3.5.1-21 544, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 144 of 161 Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Cracking None Required III.A3.1-h 3.5.1-25 547, A Building Framing
- Concrete, Exposed (foundations, masonry/
concrete wall,
- grout, reinforcements, concrete around expansion &
grouted anchors, etc.)
Flood Protection Shelter/
Protection Structural Support for Non-Safety Related Structural Support for Regulated Events Structural Support for Safety Related Concrete Atmosphere/
Weather (Ext)
Change in Material Properties Structural Monitoring Program III.A3.1-b 3.5.1-20 A
III.A3.1-f 3.5.1-20 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 145 of 161 Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Cracking Structural Monitoring Program III.A3.3-a 3.5.1-24 A
III.A3.1-a 3.5.1-20 A
III.A3.1-h 3.5.1-25 A
Cracking and Expansion Structural Monitoring Program III.A3.1-c 3.5.1-20 A
Cracking, Loss of Bond/Matl Structural Monitoring Program III.A3.1-d 3.5.1-20 A
Loss of Material Structural Monitoring Program III.A3.1-a 3.5.1-20 A
III.A3.1-f 3.5.1-20 A
Reduction in Concrete Anchor Capacity Structural Monitoring Program III.B5.2-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 146 of 161 Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Building Framing
- Concrete, Protected (foundations, concrete &
masonry wall, column, beam, floor/roof slab,
- grout, reinforcements, concrete around expansion &
grouted anchors, etc.)
Flood Protection HELB Shielding Missile Barrier Shelter/
Protection Structural Support for Non-Safety Related Structural Support for Regulated Events Structural Support for Safety Related Concrete Plant Indoor Air (Ext)
Cracking Structural Monitoring Program III.A3.3-a 3.5.1-24 A
III.A3.1-h 3.5.1-25 A
Cracking and Expansion Structural Monitoring Program III.A3.1-c 3.5.1-20 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 147 of 161 Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Cracking, Loss of Bond/Matl Structural Monitoring Program III.A3.1-d 3.5.1-20 A
Loss of Material Structural Monitoring Program III.A3.1-f 3.5.1-20 A
Loss of Strength Structural Monitoring Program III.A3.1-b 3.5.1-20 A
Reduction in Concrete Anchor Capacity Structural Monitoring Program III.B5.2-a 3.5.1-29 A
Building Framing
- Sliding
- Material, Protected (vertical supports with sliding surfaces)
Expansion /
Separation Bronze Plant Indoor Air (Ext)
Loss of Material None Required III.A4.2-b 3.5.1-20 586, I N/A N/A A, 586, 5004
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 148 of 161 Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Building Framing
- Water Treatment Area -
Carbon Steel, Protected (column, beam,
- bracing, threaded fastener, weld, etc.)
Structural Support for Non-Safety Related Structural Support for Regulated Events Carbon Steel Plant Indoor Air (Ext)
Loss of Material Structural Monitoring Program III.A3.2-a 3.5.1-20 580, A Building Framing
- Water Treatment Area -
Concrete, Below Grade (wall, pedestal, grade beam,
- footing, foundation, slab,
- grout, reinforcement, trenches, cable pits, tunnels, etc.)
Structural Support for Non-Safety Related Structural Support for Regulated Events Concrete Soil (Ext)
Loss of Material None Required III.A3.1-a 3.5.1-20 571, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 149 of 161 Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes III.A3.1-g 3.5.1-21 544, A Change in Material Properties None Required III.A3.1-b 3.5.1-20 557, A III.A3.1-g 3.5.1-21 544, A Cracking and Expansion None Required III.A3.1-c 3.5.1-20 543, A Cracking, Loss of Bond/Matl None Required III.A3.1-e 3.5.1-21 544, A Cracking None Required III.A3.1-h 3.5.1-25 547, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 150 of 161 Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Building Framing
- Water Treatment Area -
- Concrete, Exposed (foundations, wall, grout, reinforcements, concrete around expansion &
grouted anchors, etc.)
Structural Support for Non-Safety Related Structural Support for Regulated Events Concrete Atmosphere/
Weather (Ext)
Change in Material Properties Structural Monitoring Program III.A3.1-b 3.5.1-20 A
III.A3.1-f 3.5.1-20 A
Cracking Structural Monitoring Program III.A3.3-a 3.5.1-24 A
III.A3.1-a 3.5.1-20 A
III.A3.1-h 3.5.1-25 A
Cracking and Expansion Structural Monitoring Program III.A3.1-c 3.5.1-20 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 151 of 161 Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Cracking, Loss of Bond/Matl Structural Monitoring Program III.A3.1-d 3.5.1-20 A
Loss of Material Structural Monitoring Program III.A3.1-a 3.5.1-20 A
III.A3.1-f 3.5.1-20 A
Reduction in Concrete Anchor Capacity Structural Monitoring Program III.B5.2-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 152 of 161 Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Building Framing
- Water Treatment Area -
- Concrete, Protected (foundations, concrete/
masonry wall, beam, floor slab,
- grout, reinforcements, concrete around expansion &
grouted anchors, etc.)
Structural Support for Regulated Events Structural Support for Non-Safety Related Concrete Plant Indoor Air (Ext)
Cracking Structural Monitoring Program III.A3.3-a 3.5.1-24 A
III.A3.1-h 3.5.1-25 A
Cracking and Expansion Structural Monitoring Program III.A3.1-c 3.5.1-20 A
Cracking, Loss of Bond/Matl Structural Monitoring Program III.A3.1-d 3.5.1-20 A
Loss of Material Structural Monitoring Program III.A3.1-f 3.5.1-20 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 153 of 161 Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Loss of Strength Structural Monitoring Program III.A3.1-b 3.5.1-20 A
Reduction in Concrete Anchor Capacity Structural Monitoring Program III.B5.2-a 3.5.1-29 A
Flood Barrier -
Carbon Steel, Protected (flood doors,
- hatch, standpipe)
Flood Protection Structural Support for Safety Related Carbon Steel Plant Indoor Air (Ext)
Loss of Leak Tightness Structural Monitoring Program III.A3.2-a 3.5.1-20 531, H N/A N/A N/A Loss of Material Structural Monitoring Program III.A3.2-a 3.5.1-20 580, C
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 154 of 161 Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes HELB/MELB Component -
Carbon Steel, Protected (curbs, floor drains, pipe whip restraints, spray shields, etc.)
Flood Protection HELB Shielding Pipe Whip Restraint Structural Support for Safety Related Carbon Steel Plant Indoor Air (Ext)
Loss of Material Structural Monitoring Program III.A3.2-a 3.5.1-20 580, C HELB/MELB Component -
- Concrete, Protected (concrete/
masonry wall, whip restraint grout, concrete around expansion &
grouted anchors, etc.)
Flood Protection HELB Shielding Pipe Whip Restraint Concrete Plant Indoor Air (Ext)
Cracking Structural Monitoring Program III.A3.3-a 3.5.1-24 A
Cracking and Expansion Structural Monitoring Program III.A3.1-c 3.5.1-20 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 155 of 161 Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Cracking, Loss of Bond/Matl Structural Monitoring Program III.A3.1-d 3.5.1-20 A
Loss of Material Structural Monitoring Program III.A3.1-f 3.5.1-20 A
Reduction in Conc Anchor Capacity Structural Monitoring Program III.B5.2-a 3.5.1-29 A
HVAC Component -
Carbon Steel, Protected (Control Room vestibule door)
Fluid Pressure Boundary Structural Support for Non-Safety Related Carbon Steel Plant Indoor Air (Ext)
Loss of Leak Tightness Structural Monitoring Program III.A3.2-a 3.5.1-20 533, H N/A N/A N/A Loss of Material Structural Monitoring Program III.A3.2-a 3.5.1-20 580, C
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 156 of 161 Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes HVAC Component -
- Concrete, Protected (Control Room vestibules, concrete &
masonry walls, floors, ceilings)
Fluid Pressure Boundary Structural Support for Non-Safety Related Concrete Plant Indoor Air (Ext)
Cracking Structural Monitoring Program III.A3.3-a 3.5.1-24 A
III.A3.1-h 3.5.1-25 A
Cracking and Expansion Structural Monitoring Program III.A3.1-c 3.5.1-20 A
Cracking, Loss of Bond/Matl Structural Monitoring Program III.A3.1-d 3.5.1-20 A
Loss of Material Structural Monitoring Program III.A3.1-f 3.5.1-20 A
Reduction in Conc Anchor Capacity Structural Monitoring Program III.B5.2-a 3.5.1-29 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 157 of 161 Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Missile Shield -
- concrete, Exposed (concrete and/or masonry walls protecting CCW room door and containment escape hatch Missile Barrier Concrete Atmosphere/
Weather (Ext)
Change in Material Properties Structural Monitoring Program III.A3.1-b 3.5.1-20 A
III.A3.1-f 3.5.1-20 A
Cracking Structural Monitoring Program III.A3.3-a 3.5.1-24 A
III.A3.1-a 3.5.1-20 A
III.A3.1-h 3.5.1-25 A
Cracking and Expansion Structural Monitoring Program III.A3.1-c 3.5.1-20 A
Cracking, Loss of Bond/Matl Structural Monitoring Program III.A3.1-d 3.5.1-20 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 158 of 161 Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Loss of Material Structural Monitoring Program III.A3.1-a 3.5.1-20 A
III.A3.1-f 3.5.1-20 A
Reduction in Conc Anchor Capacity Structural Monitoring Program III.B5.2-a 3.5.1-29 A
Missile Shield -
- Concrete, Protected (concrete/
masonry walls, floor, & roof protecting Control Room Door)
Missile Barrier Concrete Plant Indoor Air (Ext)
Cracking Structural Monitoring Program III.A3.1-h 3.5.1-25 A
Cracking and Expansion Structural Monitoring Program III.A3.1-c 3.5.1-20 A
Cracking, Loss of Bond/Matl Structural Monitoring Program III.A3.1-d 3.5.1-20 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 159 of 161 Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Loss of Material Structural Monitoring Program III.A3.1-f 3.5.1-20 A
Reduction in Conc Anchor Capacity Structural Monitoring Program III.B5.2-a 3.5.1-29 A
Operator Access Component -
Carbon Steel, Protected (stairs, floors, platforms)
Structural Support for Non-Safety Related Structural Support for Regulated Events Carbon Steel Plant Indoor Air (Ext)
Loss of Material Structural Monitoring Program III.A3.2-a 3.5.1-20 A
Operator Access Component -
- Concrete, Protected (stairs, floors, platforms, concrete at locations of expansion &
grouted anchors, etc.)
Structural Support for Non-Safety Related Structural Support for Regulated Events Concrete Plant Indoor Air (Ext)
Cracking Structural Monitoring Program III.A3.3-a 3.5.1-24 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 160 of 161 Table 3.5.2-10 Structures and Component Supports - Turbine Building - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes III.A3.1-h 3.5.1-25 A
Cracking and Expansion Structural Monitoring Program III.A3.1-c 3.5.1-20 A
Cracking, Loss of Bond/Matl Structural Monitoring Program III.A3.1-d 3.5.1-20 A
Loss of Material Structural Monitoring Program III.A3.1-f 3.5.1-20 A
Loss of Strength Structural Monitoring Program III.A3.1-b 3.5.1-20 A
Reduction in Conc Anchor Capacity Structural Monitoring Program III.B5.2-a 3.5.1-29 A
Operator Access Component -
Galvanized, Protected (stairs, floors, platforms)
Structural Support for Non-Safety Related Structural Support for Regulated Events Galvanized Plant Indoor Air (Ext)
Loss of Material Structural Monitoring Program III.A3.2-a 3.5.1-20 581, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.5, Structures and Component Supports 161 of 161 Civil /Structural Precedent Review Plant Specific Notes:
NOTE: See Notes for Tables 3.5.2-1 through 3.5.2-10 (immediately following Table 3.5.2-10) of the Palisades License Renewal Application for list of Standard (A through J) and Plant Specific Notes (5XX series). Below are plant specific notes related to the Precedent Review of Tables 3.5.2-1 through 3.5.2-10.
N/A No precedent found. In cases where another plant's SER is cited in the Note column as a precedent using notes 5000 through 5004, a standard letter note is provided to facilitate NRC review assignments. In these cases, the letter note should be interpreted as an indicator of Palisades' consistency with the cited precedent (and, therefore, still subject to audit team review), and not to indicate consistency with Revision 1 of NUREG 1801.
5000. Precedents for built up roofing exist in the following Safety Evaluation Reports:
- Ginna, NUREG 1786, Section 3.5.2.4.2
- Dresden/Quad Cities, NUREG 1796, Section 3.5.2.4.2
- McGuire/Catawba, NUREG 1772, Section 3.5.2.1 5001. Loss of Material due to abrasion is the aging effect and mechanism evaluated and being managed by Palisades. It is considered sufficiently similar to GALL aging effect/mechanism of Increased hardness, shrinkage and loss of strength / weathering since separation from the protected component is the end result of both. The Fire Protection Program is consistent with GALL with exceptions, resulting in a standard note B.
5002. The Safety Evaluation Report (SER) for Dresden/Quad Cities, NUREG 1796, provides a precedent in Section 3.3.2.4.5 for fire wraps. Dresden/Quad Cities fire wraps are ceramic fiber with an aging effect/mechanism of separation/deterioration of metal. Palisades fire wrap components consist of rigid cementitious or fibrous material as well as cable tray insulation covers. Palisades aging effects/mechanisms of cracking due to vibration and loss of material due to abrasion results in the same aging effect of separation from the protected component. The Fire Protection Program is consistent with GALL with exceptions, resulting in a standard note B.
5003. The Safety Evaluation Report (SER) for Dresden/Quad Cities, NUREG 1796, provides a precedent in Section 3.5.2.4.2 for elastomers/roofing. Dresden Quad Cities aging effects/mechanisms of hardening cracking/elastomers degradation and change in material properties/loss of resiliency, loss of strength, loss of elasticity match well with Palisades cracking/thermal exposure and change in material properties/thermal exposure.
5004. The Safety Evaluation Report (SER) for H. B. Robinson, NUREG 1785, provides a precedent in Section 3.5.2.4.1.2 for no aging effects for bronze/Lubrite.
Similar to H. B. Robinson, Palisades' past ISI inspections of the Steam Generator and Primary Coolant Pump supports have identified no recordable degradation of Lubrite sliding plates.