Application for Renewed Operating License - Palisades Nuclear Plant Precedent Table for Section 3.2, Engineered Safety Features 1 of 9 6/7/2005 Table 3.2.2-1 Engineered Safety Features - Engineering Safeguards System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG -
1801 Notes SIRW Tank Fluid Pressure Boundary Aluminum Treated Water (Int) Cracking Water Chemistry Program V.D1.8-a 3.2.1-15 F, 210 V.D2-16 2-10 A
One-Time Inspection Program V.D1.8-a 3.2.1-15 F, 210 V.D2-16 2-10 B, 2001 Safety Injection Tank Fluid Pressure Boundary Carbon Steel w/SS clad lining Containment Air (Ext)
Loss of Material Boric Acid Corrosion Program V.D1.7-a 3.2.1-17 A
System Monitoring Program V.E1-b 3.2.1-10 A
SDC HX Shell Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Loss of Material Boric Acid Corrosion Program V.D1.5-b 3.2.1-17 A
Treated Water (Int) Loss of Material Closed Cycle Cooling Water Program V.D1.5-a 3.2.1-13 B
SIRWT HX Shell Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Loss of Material Boric Acid Corrosion Program V.D1.6-d 3.2.1-17 A
Steam (Int)
Loss of Material Water Chemistry Program G, 211 VIII.J-3 4-2 C
One-Time Inspection Program G, 211 VIII.J-3 4-2 D
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Table for Section 3.2, Engineered Safety Features 2 of 9 6/7/2005 Table 3.2.2-1 Engineered Safety Features - Engineering Safeguards System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG -
1801 Notes SDC, SIRWT HX Shell Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Loss of Material System Monitoring Program V.E1-b 3.2.1-10 A
SDC HX Channel Head Fluid Pressure Boundary Carbon Steel w/SS clad lining Plant Indoor Air (Ext)
Loss of Material Boric Acid Corrosion Program V.D1.5-b 3.2.1-17 A
System Monitoring Program V.E1-b 3.2.1-10 A
SDC HX Tube Sheet shell side Fluid Pressure Boundary Carbon Steel w/SS clad lining Treated Water (Ext)
Loss of Material Closed Cycle Cooling Water Program V.D1.5-a 3.2.1-13 B
SDC HX Channel Head shell side Fluid Pressure Boundary Carbon Steel w/SS clad lining Treated Water (Int) Loss of Material Closed Cycle Cooling Water Program V.D1.5-a 3.2.1-13 B
Cont. Spray Pump HX shell, LPSI Pump HX shell Fluid Pressure Boundary Cast Iron Plant Indoor Air (Ext)
Loss of Material Boric Acid Corrosion Program V.E1-a 3.2.1-17 A
System Monitoring Program V.E1-b 3.2.1-10 A
Treated Water (Int) Loss of Material Closed Cycle Cooling Water Program V.D1.5-a 3.2.1-13 H, 212 V.A-12 2-19 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Table for Section 3.2, Engineered Safety Features 3 of 9 6/7/2005 Table 3.2.2-1 Engineered Safety Features - Engineering Safeguards System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG -
1801 Notes One-Time Inspection Program V.D1.5-a 3.2.1-13 H, 212 V.A-12 2-19 B
SIRWT HX Tubes Fluid Pressure Boundary Stainless Steel Steam (Ext)
Cracking Heat Transfer Degradation Loss of Material Water Chemistry Program V.D1.6-a 3.2.1-13 G, 211 VIII.B1-2 V.A-10 VIII.B2-2 4-20 2-24 4-29 C
C C
One-Time Inspection Program V.D1.6-a 3.2.1-13 G, 211 IV.D1-9 1-61 E
Cont. Spray, LPSI Pump coils Fluid Pressure Boundary Stainless Steel Treated Water (Ext)
Cracking Closed Cycle Cooling Water Program V.D1.5-a 3.2.1-13 H
V.D1-19 2-31 E
PCP Seal Cooler Coils, Cont.
Spray Pump coils, LPSI pump Coils, SDC HX Tubes Fluid Pressure Boundary Heat Transfer Stainless Steel Treated Water (Ext)
Heat Transfer Degradation Closed Cycle Cooling Water Program V.D1.5-a 3.2.1-13 H
VII.C2-2 3-40 A
Loss of Material Closed Cycle Cooling Water Program V.D1.5-a 3.2.1-13 B
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Table for Section 3.2, Engineered Safety Features 4 of 9 6/7/2005 Table 3.2.2-1 Engineered Safety Features - Engineering Safeguards System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG -
1801 Notes SDC HX Tubes Fluid Pressure Boundary Heat Transfer Stainless Steel Treated Water (Ext)
Loss of Material Closed Cycle Cooling Water Program V.D1.5-a 3.2.1-13 B
PCP Seal Cooler Coils, SIRWT HX Tubes Fluid Pressure Boundary Heat Transfer Stainless Steel Treated Water (Int) Cracking Water Chemistry Program V.D1.5-a 3.2.1-13 H
V.D1-19 2-31 C
PCP Seal Cooler Coils Fluid Pressure Boundary Stainless Steel Treated Water (Int) Cracking Closed Cycle Cooling Water Program V.D1.5-a 3.2.1-13 H
VIII.E-34 4-9 E
Loss of Material Closed Cycle Cooling Water Program V.D1.5-a 3.2.1-13 B
SIRWT HX Tubes Fluid Pressure Boundary Heat Transfer Stainless Steel Treated Water (Int) Cracking One-Time Inspection Program V.D1.6-a 3.2.1-13 G
V.D1-19 2-31 D
Cont. Spray Pump Coils, SDC HX Tubes Fluid Pressure Boundary Heat Transfer Stainless Steel Treated Water (Int) Heat Transfer Degradation Water Chemistry Program V.D1.5-a 3.2.1-13 H
V.D2-10 2-24 A
Loss of Material Water Chemistry Program V.D1.5-a 3.2.1-13 A, 204
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Table for Section 3.2, Engineered Safety Features 5 of 9 6/7/2005 Table 3.2.2-1 Engineered Safety Features - Engineering Safeguards System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG -
1801 Notes SIRWT HX Tubes, Cont.
Spray Pump coils, LPSI Pump coils, SDC HX Tubes Fluid Pressure Boundary Stainless Steel Treated Water (Int) Heat Transfer Degradation One-Time Inspection Program V.D1.5-a 3.2.1-13 H
V.D2-10 2-24 B
Loss of Material One-Time Inspection Program V.D1.6-a 3.2.1-13 G
V.D2-23 2-3 B
Fasteners Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Containment Air (Ext)
Loss of Preload Bolting Integrity Program 206, F V.E-5 2-25 A
Loss of Material Bolting Integrity Program V.E.2-a 3.2.1-18 A
Stainless Steel Plant Indoor Air (Ext)
Containment Air (Ext)
Loss of Preload Bolting Integrity Program 206, F IV.C2-9 1-44 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Table for Section 3.2, Engineered Safety Features 6 of 9 6/7/2005 Table 3.2.2-1 Engineered Safety Features - Engineering Safeguards System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG -
1801 Notes Containment Spray System Fasteners Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Containment Air (Ext)
Loss of Material Boric Acid Corrosion Program V.A.1-b 3.2.1-17 A
Containment Spray Pump Bolting Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Loss of Material Boric Acid Corrosion Program V.A.3-b 3.2.1-17 A
Containment Spray System Valves Bolting Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Containment Air (Ext)
Loss of Material Boric Acid Corrosion Program V.A.4-b 3.2.1-17 A
Containment Spray System Valves Header Bolting Fluid Pressure Boundary Carbon Steel Containment Air (Ext)
Loss of Material Boric Acid Corrosion Program V.A.5-b 3.2.1-15 A
HPSI, LPSI Pumps Bolting Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Loss of Material Boric Acid Corrosion Program V.D1.2-b 3.2.1-17 A
SIRWT HX Bolting Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Loss of Material Boric Acid Corrosion Program V.D1.6-d 3.2.1-17 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Table for Section 3.2, Engineered Safety Features 7 of 9 6/7/2005 Table 3.2.2-1 Engineered Safety Features - Engineering Safeguards System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG -
1801 Notes SIRWT Bolting Fluid Pressure Boundary Carbon Steel Atmosphere/
Weather (Ext)
Loss of Material Boric Acid Corrosion Program V.D1.8-b 3.2.1-17 A
HPSI Check Valves, SDC from PCS MOVs Fluid Pressure Boundary Cast Austenitic SS Treated Water (Int) Cracking Water Chemistry Program G, 207 IV.C2-6 1-68 A
One-Time Inspection Program G, 207 IV.C2-6 1-68 E
Reduction of Fracture Toughness ASME Section XI IWB, IWC, IWD, IWF Inservice Inspection Program V.D1.1-b 3.2.1-11 E, 209 HPSI Check Valves Fluid Pressure Boundary Cast Austenitic SS Treated Water (Int) Loss of Material Water Chemistry Program G, 207 IV.C2-6 1-68 A, 2001 One-Time Inspection Program G, 207 IV.C2-6 1-68 E, 2001 Hot Leg Injection Check Valves Fluid Pressure Boundary Cast Austenitic SS Treated Water (Int) Cracking Water Chemistry Program G, 207 IV.C2-6 1-68 E
One-Time Inspection Program G, 207 IV.C2-6 1-68 E
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Table for Section 3.2, Engineered Safety Features 8 of 9 6/7/2005 Table 3.2.2-1 Engineered Safety Features - Engineering Safeguards System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG -
1801 Notes HPSI Check Valves Loops 1A, 2A Fluid Pressure Boundary Stainless Steel Treated Water (Int) Loss of Material Water Chemistry Program G, 207 V.D2-23 2-3 A, 2001 One-Time Inspection Program G, 207 V.D2-23 2-3 B, 2001 Piping and Fittings Fluid Pressure boundary Stainless Steel Treated Water (Int) Cracking Water Chemistry Program V.D1.1-a 3.2.1-15 A, 214 One-Time Inspection Program V.D1.1-a 3.2.1-15 A, 214 Loss of Material Water Chemistry Program V.D1.1-a 3.2.1-05 H, 205, 214 V.C-4 2-3 C, 205, 214 One-Time Inspection Program V.D1.1-a 3.2.1-05 H, 205, 214 V.C-4 2-3 C, 205, 214 Pumps Fluid Pressure boundary Stainless Steel Treated Water (Int) Loss of Material Water Chemistry Program V.D1.2-a 3.2.1-05 H, 205, 214, 215 V.C-4 2-3 C, 205, 214 One-Time Inspection Program V.D1.2-a 3.2.1-05 H, 205, 214, 215 V.C-4 2-3 C, 205, 214
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Table for Section 3.2, Engineered Safety Features 9 of 9 6/7/2005 Table 3.2.2-1 Engineered Safety Features - Engineering Safeguards System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG -
1801 Notes Spray Nozzles Spray Pattern Stainless Steel Air (Ext)
None None Required F, 208, 214 V.F-15 2-40 A, 214 TriSodium Phosphate Baskets Structure Functional Support Stainless Steel Containment Air (Ext)
None None Required J, 213, 214 V.F-15 2-40 A, 214 Note 2001: This material and environment combination is shown in GALL as not having the specified AERM. For the purpose of precedent review, Palisades considered Notes A, B, C, or D to apply to those instances where we are managing items which GALL does not indicate need to be managed.
Information in blue and the following new notes were added to the LRA via supplementary letter dated 5/5/05.
Note 205: Palisades manages pitting and crevice corrosion.
Note 208: Palisades spray nozzles are stainless steel. GALL indicates carbon steel.
Note 213: Component is not in GALL.
Note 214: This row was added to the original application in a supplementary letter.
Note 215: This component normally operates at below 140 degrees F. Therefore, SCC is not an applicable aging mechanism.